LER 79-026/03L-0 on 790719:water Leak from Cracked Weld on Reactor Coolant Charging Pump Discharge Drain Valve Observed.Caused by Crack in heat-affected Zone of Socket Weld.Pump Removed & Cracked Pipe Spool Replaced
ML19247B614
Person / Time
Site: Calvert Cliffs Constellation icon.png
Issue date: 07/19/1979
From: Heibel R, Miernicki M
BALTIMORE GAS & ELECTRIC CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
Shared Package
ML19247B613 List:
References
LER-79-026-03L, LER-79-26-3L, NUDOCS 7908100503