ML17340A553

From kanterella
Revision as of 12:22, 18 June 2019 by StriderTol (talk | contribs) (Created page by program invented by StriderTol)
Jump to navigation Jump to search
Forwards Proposed Amend to App a of Licenses DPR-31 & DPR-41,to Provide for Redundancy in Decay Heat Removal Sys for All Modes of Reactor Operation,In Response to NRC 800611 Request
ML17340A553
Person / Time
Site: Turkey Point  NextEra Energy icon.png
Issue date: 12/30/1980
From: Robert E. Uhrig
FLORIDA POWER & LIGHT CO.
To: Eisenhut D
Office of Nuclear Reactor Regulation
Shared Package
ML17340A554 List:
References
L-80-427, NUDOCS 8101060297
Download: ML17340A553 (6)


Text

0 REGULATORY INFORMATION DISTRIBUTION TEM (RIDS)ACCESSION NBR: 8101060297 DOC, DATE: 80/12/30 NOTARIZED:

NO FACIL:50-250 Turkey Point Planti Unit 3g Florida Power and Light C 50 251 Turkey Point Planti Unit 4~Florida Power and Light C AUTH BYNAME AUTHOR AFFILIATION UHRIGg R~E~Florida Power 8.Light Co.RECIP~NAME RECIPIENT AFFILIATION EISENHUT<D,G, Division of Licensing DOCKET 05000250 05000251

SUBJECT:

Forwards proposed amend to App A of Licenses DPR 31 8 DPR 41eto provide for redundancy in decay heat removal sys for all modes of reactor operationrin response to NRC 800611 requests DISTRIBUTION CODE: A001S COPIES RECEIVED:LTR ENCI SIZE:'3 3 g+Io TITLE: Gener al Distribution for after Issuance of Operating, License NOTES: RECIPIENT ID CODE/NAME.

ACTION: VARGA r S~04 COPIES LTTR ENCL 13 13 RECIPIENT ID CODE/NAME COPIES LTTR ENCL INTERNAL: D/DIRpHUM I8,E REG F ILE FAC08 06 11 01 1 1 2 2 1 0 1 1 DIRr DIV OF LIC NRC PDR'2 OR ASSESS BR 10 EXTER: ACRS NSIC 09 05 16 16 1 LPDR 03 JAN~t987 TOTAL NUMBER OF COPIES'EQUIRED

~LTTR 39 ENCL 37 4tZ A'.(g~,'f II>ml cn CA~D M CD V"ix)~t/7 CD C~I Cv CN (PP J FLORIDA POWER 8L LIGHT COMPANY December 30, 1980 L-80-427 Office of Nuclear Reactor Regulation Attention:

Mr.Darrell G.Eisenhut, Director Division of Licensing U.S.Nuclear Regulatory Commission Washington, D.C.20555

Dear Mr.Eisenhut:

Re: Turkey Point Units 3 and 4 Docket Nos.50-250 and 50-251 Proposed Amendment to Facility 0 eratin Licenses DPR-31 and DPR-41 In accordance with 10 CFR 50.30, Florida Power&Light Company submits herewith three (3)signed originals and forty (40)copies of a request to amend Appendix A of Facility Operating Licenses DPR-31 and DPR-41.This amendment is submitted in response to your letter dated June ll, 1980, requesting that the Technical Specifications be modified to provide for redundancy in decay heat removal systems for all modes of reactor operation.

The proposed amendment is attached to this letter and includes the accompanying Technical Specification pages bearing the date of this letter in the lower right hand corner.In developing the proposed amendment we adapted the STS wording to the format of the existing Turkey Point Technical Specifications.

The proposed amendment has been reviewed by the Turkey Point Plant Nuclear Safety Committee and the Florida Pouter&Light Company Nuclear Review Board.They have concluded that it does not involve an unreviewed safety question.Very truly yours, Robert E.Uhrig Vice President Advanced Systems&Technology REU/PLP/pah Attachment ool 5>/~cc: Mr.J.P.O'Reilly, Region II Harold F.Reis, Esquire>>Oioeogfg PEOPLE...SERVING PEOPLE 41 0 Re: Turkey Point Units 3 and 4 Docket No.50-250 and 50-251 ,Proposed Amendment to Facility 0 eratin Licenses DPR-31 and DPR-41 PROPOSED CHANGES~Pe e 1-6 Add definition of Coolant Loop.Pa es 3.4-.2a 3.4-3 Delete paragraphs 3.4.l.b.4 through 3.4-1-b-6.Add paragraphs to require redundant Coolant Loops to be.operable or operating in.each mode of reactor operation.

Table 4.1-2 Add additional surveillance items to ensure the, operability of RHR and RCS components.

P,a e B3.1-1 and B3.1-la Change to include additional bases for redundancy in the RC and RHR systems-Ik