{{#Wiki_filter:2006 Fermi-2 NRC RO License Exam - Retake RO 2 Tier 3 K/A Number Generic Statement 2.1.11 IR 3.0 Origin N Source Question N/A LOK F (1F)  10 CFR 55.41(b) 10 LOD (1-5) 2.5 Reference Documents Tech Spec 3.8.1 QUESTION 1  
{{#Wiki_filter:2006 Fermi-2 NRC RO License Exam - Retake RO       Tier       K/A Number           Statement      IR    Origin  Source Question 2        3            Generic             2.1.11     3.0     N     N/A LOK               10 CFR 55.41(b) 10     LOD (1-5)     Reference Documents F (1F)                                          2.5       Tech Spec 3.8.1 QUESTION 1 With the plant in MODE 1, Emergency Diesel Generator 13 has been declared INOPERABLE.
 
Which one of the following Tech Spec Required Actions has a specified Required Completion Time WITHIN ONE HOUR?
With the plant in MODE 1, Emergency Diesel Generator 13 has been declared INOPERABLE.
_____ A.       Verify that CTG 11-1 is AVAILABLE.
Which one of the following Tech Spec Required Actions has a specified Required Completion Time WITHIN ONE HOUR
_____ B.       Verify Offsite Power Sources are OPERABLE.
?
_____ C.       Verify that EDGs 11, 12, and 14 are not also INOPERABLE due to common cause failure.
 
_____ D.       Declare the required features supported by EDG 13 INOPERABLE when the redundant required features are INOPERABLE.
_____ A. Verify that CTG 11-1 is AVAILABLE.  
Correct Answer : B 3.8.1 Condition A, Required Action A.1 Perform SR 3.8.1.1. for OPERABLE offsite circuit(s) within 1 hour.
 
_____ B. Verify Offsite Power Sources are OPERABLE.  
 
_____ C. Verify that EDGs 11, 12, and 14 are not also INOPERABLE due to common cause failure. _____ D. Declare the required features supported by EDG 13 INOPERABLE when the redundant required featur es are INOPERABLE.  
 
Correct Answer : B 3.8.1 Condition A, Required Action A.1 "Per form SR 3.8.1.1. for OPERABLE offsite circuit(s) within 1 hour.
Plausible Distractors:
Plausible Distractors:
A is plausible, Completion Time is once per [[estimated NRC review hours::8 hours]].
A is plausible, Completion Time is once per [[estimated NRC review hours::8 hours]].
C is plausible, Completion Time is within 4 hou rs of discovery of inoperable EDG concurrent with inoperability of red undant required features. D is plausible, Completion Time is within [[estimated NRC review hours::24 hours]].
C is plausible, Completion Time is within [[estimated NRC review hours::4 hours]] of discovery of inoperable EDG concurrent with inoperability of redundant required features.
Objective Link: ST-OP-315-0065-001-C012 2006 Fermi-2 NRC RO License Exam - Retake RO 3 Tier 3 K/A Number Generic Statement 2.1.29 IR 3.4 Origin B Source Question  Fermi-2 2003 NRC Exam LOK F (1P)  10 CFR 55.41(b) 10LOD (1-5) 2.5 Reference Documents MOP02, Rev 8 QUESTION 2 
D is plausible, Completion Time is within [[estimated NRC review hours::24 hours]].
Objective Link: ST-OP-315-0065-001-C012


Performance of a pre-startup valve lineup will involve aligning a valve that is to be LOCKED CLOSED. The valve in question is located in a CONTAMINATED work area.
2006 Fermi-2 NRC RO License Exam - Retake RO      Tier        K/A Number            Statement        IR    Origin    Source Question 3        3            Generic              2.1.29        3.4      B      Fermi-2 2003 NRC Exam LOK                10 CFR 55.41(b) 10      LOD (1-5)      Reference Documents F (1P)                                          2.5        MOP02, Rev 8 QUESTION 2 Performance of a pre-startup valve lineup will involve aligning a valve that is to be LOCKED CLOSED. The valve in question is located in a CONTAMINATED work area.
 
In this situation, per MOP02, Independent Verification, independent verification of valve position ______________________.
In this situation, per MOP02, "Independent Veri fication", independent verification of valve position ______________________.  
_____ A.       is accomplished by visual verification that the locking device is properly installed.
 
_____ B.       is performed by removing the locking device, checking the valve position, and re-installing the locking device.
_____ A. is accomplished by visual verification that the locking device is properly installed.
_____ C.       should be performed by hands on checking of the valve position without removing or breaking the locking device.
 
_____ D.       may be waived by the CRS to conserve man-rem rather than require two individuals to enter the contaminated area.
_____ B. is performed by removing the locking device, checking the valve position, and re-installing the locking device.  
Correct Answer : C Second individual performs a hands on independent verification of the component without removing or breaking the locking device per MOP02.
 
Plausible Distractors:
_____ C. should be performed by hands on checking of the valv e position without removing or breaking the locking device.  
A is plausible, it is required to verify locking device installed properly, in addition to verifying valve position. Procedure requires hands on verification.
 
_____ D. may be waived by the CRS to conserve man-rem rather than require two   individuals to enter the contaminated area.  
 
Correct Answer : C Second individual performs a hands on independen t verification of the component without   removing or breaking the locking device per MOP02.
Plausible Distractors: A is plausible, it is required to verify locki ng device installed properly, in addition to verifying valve position. Procedure require s "hands on" verification.
B is plausible, but not procedural per MOP02.
B is plausible, but not procedural per MOP02.
D is plausible, supervision may waive verifi cation for radiation dos e considerations, NOT contamination conditions.
D is plausible, supervision may waive verification for radiation dose considerations, NOT contamination conditions.
Objective Link: LP-OP-802-4201-0009  
Objective Link: LP-OP-802-4201-0009


2006 Fermi-2 NRC RO License Exam - Retake RO 4 Tier 3 K/A Number Generic Statement 2.2.11 IR 2.5 Origin B Source Question N/A LOK F (1B)  10 CFR 55.41(b) 10 LOD (1-5) 2.5 Reference Documents MGA04 Rev 14 QUESTION 3  
2006 Fermi-2 NRC RO License Exam - Retake RO     Tier       K/A Number           Statement      IR    Origin Source Question 4        3            Generic             2.2.11       2.5     B   N/A LOK               10 CFR 55.41(b) 10     LOD (1-5)       Reference Documents F (1B)                                          2.5       MGA04 Rev 14 QUESTION 3 A change to a procedure using the Temporary Change Notice process is appropriate in which of the following situations?
 
_____ A.       To correct an incorrect source reference.
A change to a procedure using the Temporary Cha nge Notice process is ap propriate in which of the following situations?  
_____ B.       To revise surveillance acceptance criteria values.
 
_____ C.       To correct an incorrect component identification.
_____ A. To correct an incorrect source reference.  
_____ D.       To implement changes to administrative procedures.
 
Correct Answer : C MGA04, Temporary Change Notices, section 3.3.2 specifically allows use of Temporary Change Notices to correct component identification errors in procedures.
_____ B. To revise surveillanc e acceptance criteria values.
_____ C. To correct an incorrect component identification.  
 
_____ D. To implement changes to administrative procedures.  
 
Correct Answer : C MGA04, "Temporary Change Notices", section 3.3.2 specifically allows use of Temporary Change Notices to correct component identification errors in procedures.
Plausible Distractors:
Plausible Distractors:
A is plausible, mentioned in MGA04 section 3.4.5 as a condition where Temporary Change Notice use is NOT allowed.
A is plausible, mentioned in MGA04 section 3.4.5 as a condition where Temporary Change Notice use is NOT allowed.
B is plausible, mentioned in MGA04 section 3.4.2 as a condition where Temporary Change Notice use is NOT allowed.
B is plausible, mentioned in MGA04 section 3.4.2 as a condition where Temporary Change Notice use is NOT allowed.
D is plausible, mentioned in MGA04 section 3.4.1 as a condition where Temporary Change Notice use is NOT allowed.
D is plausible, mentioned in MGA04 section 3.4.1 as a condition where Temporary Change Notice use is NOT allowed.
Objective Link: LP-OP-802-4101-0013  
Objective Link: LP-OP-802-4101-0013


2006 Fermi-2 NRC RO License Exam - Retake RO 5 Tier 3 K/A Number Generic Statement 2.2.30 IR 3.5 Origin B Source Question  Fermi-2 2003 NRC Exam LOK F (1B)  10 CFR 55.41(b) 10LOD (1-5) 3.0 Reference Documents Technical Specifications Technical Requirements Manual QUESTION 4  
2006 Fermi-2 NRC RO License Exam - Retake RO     Tier       K/A Number         Statement        IR    Origin  Source Question 5        3            Generic           2.2.30         3.5     B     Fermi-2 2003 NRC Exam LOK             10 CFR 55.41(b) 10      LOD (1-5)       Reference Documents F (1B)                                        3.0         Technical Specifications Technical Requirements Manual QUESTION 4 Which one of the following statements is a Technical Specification/Technical Requirement Manual requirement when moving fuel during Core Alterations?
 
_____ A.       ALL SRMs SHALL be Operable.
Which one of the following statements is a Technical Specification/Technical Requirement Manual requirement when moving fuel during Core Alterations?  
_____ B.       The Fuel Preparation Machines MAY NOT be used for storing fuel.
 
_____ C.       The Refueling Platform Main Hoist is the ONLY lifting device permitted to transport fuel.
_____ A.
_____ D.       Direct communications SHALL be maintained between the Refueling Platform and the Control Room.
ALL SRMs SHALL be Operable.
Correct Answer : D Direct communications shall be maintained between the Refueling Platform and the Control Room is required by the Technical Requirements Manual.
 
Plausible Distractors:
_____ B. The Fuel Preparation Machines MAY NOT be used for storing fuel.  
A is plausible, during REFUEL, Tech Specs require only two SRMs Operable.
 
B is plausible, there is no TS or TRM prohibition for the use of the Fuel Preparation Machine.
_____ C. The Refueling Platform Main Hoist is the ONLY lifting device permitted to transport fuel.  
C is plausible, there is no TS or TRM restriction requiring use of ONLY the Refueling Platform Main Hoist.
 
Objective Link: LP-OP-802-4101-0030
_____ D. Direct communications SHALL be maintained between the Refueling Platform and the Control Room.  


Correct Answer :  D Direct communications shall be maintained between the Refueling Platform and the Control Room is required by the Technical Requirements Manual.
2006 Fermi-2 NRC RO License Exam - Retake RO      Tier        K/A Number          Statement    IR    Origin Source Question 8        3            Generic              2.3.2      2.5    B    Fermi-2 2003 NRC Exam LOK                10 CFR 55.41(b) 12    LOD (1-5)    Reference Documents F (1F)                                          2.3      MRP10 Rev 3 QUESTION 5 Which one of the following describes the embryo/fetus Federal Dose Limits and the Fermi - 2 Administrative Dose Guidelines for radiation workers?
_____ A.        100 mrem spread over the term of the pregnancy.
_____ B.        500 mrem spread over the term of the pregnancy.
_____ C.        750 mrem spread over the term of the pregnancy.
_____ D.      1000 mrem spread over the term of the pregnancy.
Correct Answer : B Stated in MRP10, Fetal Protection Program.
Plausible Distractors:
Plausible Distractors:
A is plausible, during REFUEL, Tech Specs require only two SRMs Operable. B is plausible, there is no TS or TRM prohibition for the use of the Fuel Preparation Machine. C is plausible, there is no TS or TRM restric tion requiring use of ONLY the Refueling Platform Main Hoist.
A is plausible, 100 mrem/year limit for non-radworkers.
Objective Link:  LP-OP-802-4101-0030
 
2006 Fermi-2 NRC RO License Exam - Retake RO 8 Tier 3 K/A Number Generic  Statement 2.3.2 IR 2.5 Origin B Source Question  Fermi-2 2003 NRC Exam LOK F (1F)  10 CFR 55.41(b) 12 LOD (1-5) 2.3 Reference Documents MRP10 Rev 3 QUESTION 5 Which one of the following describes the embryo/fetus Federal Dose Limits and the Fermi - 2 Administrative Dose Guidelines for radiation workers?
 
_____ A. 100 mrem spread over the term of the pregnancy. 
 
_____ B. 500 mrem spread over the term of the pregnancy. 
 
_____ C. 750 mrem spread over the term of the pregnancy.
_____ D. 1000 mrem spread over the term of the pregnancy. 
 
Correct Answer :  B Stated in MRP10, "Fetal Protection Program".
Plausible Distractors:  A is plausible, 100 mrem/year limit for non-radworkers.
C is plausible, if 500 mrem limit is not known.
C is plausible, if 500 mrem limit is not known.
D is plausible, Fermi annual limit for radworkers.
D is plausible, Fermi annual limit for radworkers.
Objective Link: LP-GN-508-0001-A017  
Objective Link: LP-GN-508-0001-A017
 
2006 Fermi-2 NRC RO License Exam - Retake RO 9 Tier 3 K/A Number Generic Statement 2.4.11 IR 3.4 Origin N Source Question N/A LOK H (3PEO/2RI)  10 CFR 55.41(b) 10 LOD (1-5) 2.7 Reference Documents 20.106.01 Rev 17 QUESTION 6


The plant is operating at 100% pow er when the following occurs:
2006 Fermi-2 NRC RO License Exam - Retake RO        Tier        K/A Number        Statement        IR  Origin  Source Question 9          3            Generic          2.4.11        3.4    N    N/A LOK                10 CFR 55.41(b) 10    LOD (1-5)      Reference Documents H                                          2.7        20.106.01 Rev 17 (3PEO/2RI)
QUESTION 6 The plant is operating at 100% power when the following occurs:
* 3D96, MOTOR TRIPPED, alarms.
* 3D96, MOTOR TRIPPED, alarms.
* 3D5, CRD CHARGING H2O PRESSURE LOW, alarms.
* 3D5, CRD CHARGING H2O PRESSURE LOW, alarms.
* 3D10, CRD ACCUMULATOR TROUBLE, alarms.
* 3D10, CRD ACCUMULATOR TROUBLE, alarms.
* Yellow ACCUM Light is LIT for Control Rod 02-31, which is at position 48.
* Yellow ACCUM Light is LIT for Control Rod 02-31, which is at position 48.
* C1106-C001A, East CRD Pump, White CMC Switch indicating light is LIT. With these conditions, the procedurally required action is to:  
* C1106-C001A, East CRD Pump, White CMC Switch indicating light is LIT.
 
With these conditions, the procedurally required action is to:
_____ A. Place the Reactor Mode Switch in SHUTDOWN IMMEDIATELY.
_____ A.       Place the Reactor Mode Switch in SHUTDOWN IMMEDIATELY.
_____ B. Place the Reactor Mode Switch in SHUTDOWN WITHIN 20 MINUTES.
_____ B.       Place the Reactor Mode Switch in SHUTDOWN WITHIN 20 MINUTES.
_____ C. Close the C1100-F034, CRD Charging Water Isolation Valve, and then                 start C1106-C001B, West CRD Pump.  
_____ C.       Close the C1100-F034, CRD Charging Water Isolation Valve, and then start C1106-C001B, West CRD Pump.
 
_____ D.       Place the CRD Flow Controller in MANUAL, close the CRD Flow Control Valve and Pressure Control Valve and then start C1106-C001B, West CRD Pump.
_____ D. Place the CRD Flow Controller in MANUAL, close the CRD Flow Control Valve                 and Pressure Control Valve and then start C1106-C001B, West CRD Pump.
Correct Answer : D Correct actions for a CRD Pump Failure per 20.106.01, CRD HYDRAULIC SYSTEM FAILURE.
 
Plausible Distractors:
Correct Answer : D Correct actions for a CRD Pump Failu re per 20.106.01, "CRD HYDRAULIC SYSTEM FAILURE".
Plausible Distractors:
 
A is plausible, correct if <900 psig.
A is plausible, correct if <900 psig.
B is plausible, correct if MORE THAN ONE Accumulator Fault occurs.
B is plausible, correct if MORE THAN ONE Accumulator Fault occurs.
C is plausible, correct if Standby CRD Pump fails to start when attempted.
C is plausible, correct if Standby CRD Pump fails to start when attempted.
Objective Link: SS-OP-802-2001 2006 Fermi-2 NRC RO License Exam - Retake RO 10 Tier 3 K/A Number Generic Statement 2.4.20 IR 3.3 Origin N Source Question N/A LOK H (2RI)  10 CFR 55.41(b) 10 LOD (1-5) 3.5 Reference Documents 29.100.01 Sheet 1, RPV Control QUESTION 7
Objective Link: SS-OP-802-2001


Following a LOCA, the following conditions exist:
2006 Fermi-2 NRC RO License Exam - Retake RO      Tier          K/A Number          Statement    IR    Origin  Source Question 10        3              Generic            2.4.20      3.3    N      N/A LOK                10 CFR 55.41(b) 10      LOD (1-5)    Reference Documents H (2RI)                                          3.5      29.100.01 Sheet 1, RPV Control QUESTION 7 Following a LOCA, the following conditions exist:
* ONLY Division 1 RHR Pumps are running.
* ONLY Division 1 RHR Pumps are running.
* ALL other ECCS systems have failed.
* ALL other ECCS systems have failed.
* Reactor Pressure is 500 psig.
* Reactor Pressure is 500 psig.
* Emergency Depressurization has NOT occurred.  
* Emergency Depressurization has NOT occurred.
 
Per the EOPs, the LOWEST stable RPV Water Level which assures Adequate Core Cooling under these conditions is ______ .
Per the EOPs, the LOWEST stable RPV Water Level which assures Adequate Core Cooling under these conditions is ______ .
_____ A.       0 (zero) inches
 
_____ B.       -20 (minus 20) inches
_____ A. 0 (zero) inches
_____ C.       -30 (minus 30) inches
_____ B. -20 (minus 20) inches  
_____ D.       -45 (minus 45) inches Correct Answer : B 29.100.01 Sheet 1 specifies maintaining injection at stable RPV Water Levels > -25 (minus 25) inches. -20 (minus 20) inches is the LOWEST stable RPV Water Level listed which assures adequate core cooling. Candidate must identify Adequate Core Cooling as operational implication of EOP notes.
 
Plausible Distractors:
_____ C. -30 (minus 30) inches  
A is plausible, but not the lowest, Core Submergence is adequate under all conditions, but adequate core cooling is assured at LOWER levels with injection.
 
C is plausible, and is correct prior to Emergency Depressurization WITHOUT Injection (Steam Cooling).
_____ D. -45 (minus 45) inches  
 
Correct Answer : B 29.100.01 Sheet 1 specifies maintaining injection at stable RPV Water Levels > -25 (minus 25) inches. -20 (minus 20) inches is the LOWEST stable RPV Water Level listed which assures adequate core cooling. Candidate must id entify Adequate Core Cooling as operational implication of EOP notes.
Plausible Distractors:
 
A is plausible, but not the lowest, Core Submergence is adequate under all conditions, but adequate core cooling is assured at LOWER levels with injection. C is plausible, and is correct prior to Emergency Depressurization WITHOUT Injection (Steam Cooling).
D is plausible, and is correct FOLLOWING Emergency Depressurization WITH one full loop of Core Spray injecting.
D is plausible, and is correct FOLLOWING Emergency Depressurization WITH one full loop of Core Spray injecting.
Objective Link: ST-OP-802-3001-001-008 2006 Fermi-2 NRC RO License Exam - Retake RO 13 Tier 1 K/A Number 295004 Statement AA1.02 IR 3.8 Origin N Source Question N/A LOK H (2RI) Grp 1 10 CFR 55.41(b) 10 LOD (1-5) 3.5 Reference Documents 20.300.260VESF, Rev 1 QUESTION 8  
Objective Link: ST-OP-802-3001-001-008


The plant is operating at 100% power with RHR Pump "A" op erating in Torus Cooling. A transient occurs, resulting in the following conditions:
2006 Fermi-2 NRC RO License Exam - Retake RO      Tier        K/A Number          Statement    IR    Origin  Source Question 13        1            295004              AA1.02      3.8    N    N/A LOK      Grp      10 CFR 55.41(b) 10      LOD (1-5)    Reference Documents H (2RI)      1                                  3.5      20.300.260VESF, Rev 1 QUESTION 8 The plant is operating at 100% power with RHR Pump A operating in Torus Cooling.
A transient occurs, resulting in the following conditions:
* ALL Control Rods are fully inserted.
* ALL Control Rods are fully inserted.
* ALL MSIVs are closed.
* ALL MSIVs are closed.
Line 156: Line 122:
* 1D6, DIV I CSS LOGIC POWER FAILURE, alarms.
* 1D6, DIV I CSS LOGIC POWER FAILURE, alarms.
* 1D8, RHR LOGIC A 125V DC BUS POWER FAILURE, alarms.
* 1D8, RHR LOGIC A 125V DC BUS POWER FAILURE, alarms.
* ALL Division 1 ECCS Pump CMC switc hes lose indication (no lights).  
* ALL Division 1 ECCS Pump CMC switches lose indication (no lights).
With the above conditions, which one of the following correctly completes the statement?
RHR Pump A is ___________.
_____ A.        RUNNING, and CAN be electrically tripped
_____ B.        RUNNING, and CANNOT be electrically tripped
_____ C.        TRIPPED, and WILL auto start on receipt of a valid signal
_____ D.        TRIPPED, and WILL NOT auto start on receipt of a valid signal Correct Answer : B RHR Pump A has lost control power, indicated by the DC Annunciators. RHR Pump A will continue to run and cannot be electrically tripped.
Plausible Distractors:
A is plausible, RHR pump loses control power and will remain running, but cannot be electrically tripped.
C is plausible, RHR pump loses control power, which is required for BOTH trip and start functions.


With the above conditions, which one of the following correctly completes the statement?
RHR Pump "A" is ___________.
_____ A.
RUNNING , and CAN be electrically tripped
_____ B.
RUNNING , and CANNOT be electrically tripped
_____ C.
TRIPPED , and WILL auto start on receipt of a valid signal
_____ D.
TRIPPED , and WILL NOT auto start on receip t of a valid signal
Correct Answer :  B RHR Pump "A" has lost control power, indi cated by the DC Annunciators. RHR Pump "A" will continue to run and cannot be electrically tripped.
Plausible Distractors: A is plausible, RHR pump loses control power and will remain running, but cannot be electrically tripped.
C is plausible, RHR pump loses control power, which is required for BOTH trip and start functions.
2006 Fermi-2 NRC RO License Exam - Retake D is plausible, RHR pump loses control power, which is required for BOTH trip and start functions.
2006 Fermi-2 NRC RO License Exam - Retake D is plausible, RHR pump loses control power, which is required for BOTH trip and start functions.
Objective Link: ST-OP-315-0045-B008 B007 B000  
Objective Link: ST-OP-315-0045-B008 B007 B000


2006 Fermi-2 NRC RO License Exam - Retake RO 11 Tier 1 K/A Number 295001 Statement AK2.01 IR 3.6 Origin N Source Question N/A LOK H (2RI) Grp 1 10 CFR 55.41(b) 10 LOD(1-5) 2.25 Reference Documents 20.138.01 Rev 40 QUESTION 9  
2006 Fermi-2 NRC RO License Exam - Retake RO       Tier         K/A Number           Statement      IR    Origin    Source Question 11        1              295001             AK2.01       3.6       N       N/A LOK       Grp       10 CFR 55.41(b) 10       LOD(1-5)     Reference Documents H (2RI)      1                                    2.25     20.138.01 Rev 40 QUESTION 9 The plant is operating in SINGLE LOOP, Reactor Power is 55%, and RRMG Set A speed is 60%, when the following alarms are received:
 
* 3D104, RECIRC PMP A MG DRIVE MTR GRD FAULT / OVERCURRENT
The plant is operating in SINGLE LOOP, Reactor Power is 55%, and RRMG Set "A" speed is 60%, when the following alarms are received:
* 3D96, MOTOR TRIPPED With these conditions, which one of the following actions is required?
* 3D104, RECIRC PMP A MG DRIVE MT R GRD FAULT / OVERCURRENT
_____ A.       Monitor for neutron flux instabilities.
* 3D96, MOTOR TRIPPED With these conditions, which one of the following actions is required?  
_____ B.       Place the Reactor Mode Switch in SHUTDOWN.
 
_____ C.        Insert control rods in sequence to restore operation outside the EXIT region of the Power to Flow Map.
_____ A. Monitor for neutron flux instabilities.  
_____ D.        Restart Reactor Recirculation Pump B and raise flow to restore operation outside the EXIT region of the Power to Flow Map.
 
Correct Answer : B Correct actions for loss of BOTH Recirculation Loops.
_____ B. Place the Reactor Mode Switch in SHUTDOWN.  
Plausible Distractors:
A is plausible, correct follow up action for loss of ONE Loop with TWO Loops initially operating.
C is plausible, also performed for loss of ONE Loop with TWO Loops initially operating.
D is plausible, higher core flow will restore operation outside the EXIT region, but pump restarts are prohibited.
Objective Link: SS-OP-802-2001-RO-0002


_____ C. Insert control rods in sequence to re store operation outside the EXIT region of the                  Power to Flow Map.  
2006 Fermi-2 NRC RO License Exam - Retake RO      Tier        K/A Number          Statement      IR    Origin    Source Question 14        1            295005              AA2.06      2.6      B      N/A LOK      Grp      10 CFR 55.41(b) 5      LOD (1-5)    Reference Documents H (2RI/      1                                  3.1      3D91, Rev 9, TS Table 3.3.1.1 3PEO)                                                    ST-OP-315-0045-001, Rev12 QUESTION 10 The plant is at 18% power when the turbine trips. The reactor will ______________.
_____ A.        remain operating AND reactor power will remain CONSTANT
_____ B.        SCRAM AND reactor pressure will INCREASE due to decay heat
_____ C.       SCRAM AND reactor pressure will DECREASE due to BPV operation
_____ D.        remain operating AND reactor power will INCREASE due to Feedwater Temperature change Correct Answer : D Justification: Candidate must know that Turbine Trip / Reactor Scram function is bypassed about 30% power. Candidate must know effect of Turbine Trip induced Feedwater Temperature change on Reactor Power. Turbine Trip / Reactor Scram is bypassed below 161.9 psig 1st Stage Turbine Pressure (30% power). Reactor will remain operating on Turbine Bypass Valves. Resulting Feedwater Temperature drop will cause Reactor Power Increase.
Plausible Distractors If candidate does not know that Turbine Trip / Reactor Scram function is bypassed below 30%
power, Scram is plausible. Feedwater Temperature will lower and cause reactor pressure to lower. Post scram pressure changes are plausible due to BPV operation and decay heat values.
Objective Link: LP-OP-315-0145-A018


_____ D. Restart Reactor Recirculation Pump "B" and raise flow to restore operation outside  the EXIT region of th e Power to Flow Map.   
2006 Fermi-2 NRC RO License Exam - Retake RO      Tier        K/A Number          Statement        IR    Origin    Source Question 6        3            Generic            2.2.22        3.4      B      Fermi-2 2001 NRC Exam LOK              10 CFR 55.41(b) 5      LOD (1-5)      Reference Documents F (1P)                                        3.2        Technical Specifications 3.4.4 QUESTION 11 From the given statements select the one that correctly describes the operational leakage allowed from the reactor coolant system in MODE 1.
 
Reactor Coolant System operational LEAKAGE shall be limited to:
Correct Answer : B Correct actions for loss of BOTH Recirculation Loops.
_____ A.        5 gpm TOTAL LEAKAGE.
_____ B.        2 gpm Pressure Boundary LEAKAGE.
_____ C.        25 gpm TOTAL LEAKAGE averaged over the previous [[estimated NRC review hours::24 hours]] and 5 gpm increase in unidentified LEAKAGE in the previous 12 hour period.
_____ D.       25 gpm TOTAL LEAKAGE averaged over the previous [[estimated NRC review hours::24 hours]] and 2 gpm increase in unidentified LEAKAGE in the previous 24 hour period.
Correct Answer : D 25 gpm TOTAL LEAKAGE averaged over the previous [[estimated NRC review hours::24 hours]] and 2 gpm increase in unidentified LEAKAGE in the previous 24 hour period. Per LCO 3.4.4, RCS Operational Leakage.
Plausible Distractors:
Plausible Distractors:
A is plausible, correct follow up action fo r loss of ONE Loop with TWO Loops initially operating.
C is plausible, also performed for loss of ONE Loop with TWO Loops initially operating. D is plausible, higher core flow will restore operation outside the EXIT region, but pump restarts are prohibited.
Objective Link:  SS-OP-802-2001-RO-0002 2006 Fermi-2 NRC RO License Exam - Retake RO 14 Tier 1 K/A Number 295005 Statement AA2.06 IR 2.6 Origin B Source Question N/A LOK H (2RI/ 3PEO) Grp 1 10 CFR 55.41(b) 5 LOD (1-5) 3.1 Reference Documents 3D91, Rev 9, TS Table 3.3.1.1
ST-OP-315-0045-001, Rev12 QUESTION 10
The plant is at 18% power when the turbine trips. The reactor will ______________.
_____ A. remain operating AND reactor power will remain CONSTANT 
_____ B. SCRAM AND reactor pressure will INCREASE due to decay heat
_____ C. SCRAM AND reactor pressure will DECREASE due to BPV operation
_____ D. remain operating AND reactor power will INCREASE due to Feedwater  Temperature change
Correct Answer :  D Justification:  Candidate must know that Tu rbine Trip / Reactor Scram function is bypassed about 30% power. Candidate must know effect of Turbine Trip induced Feedwater Temperature change on Reactor Power. Turbine Trip / Reactor Scram is bypassed below 161.9 psig 1st Stage Turbine Pressure (30% power). Reactor will remain operating on Turbine Bypass Valves. Resulting Feedwater Temperature drop will cause Reactor Power Increase.
Plausible Distractors 
If candidate does not know that Turbine Trip / Reactor Scram function is bypassed below 30% power, Scram is plausible. Feedwater Temperature will lower and cause reactor pressure to lower. Post scram pressure changes are plausible due to BPV operation and decay heat values.
Objective Link:  LP-OP-315-0145-A018
2006 Fermi-2 NRC RO License Exam - Retake RO 6 Tier 3 K/A Number Generic Statement 2.2.22 IR 3.4 Origin B Source Question  Fermi-2 2001 NRC Exam  LOK F (1P)  10 CFR 55.41(b) 5 LOD (1-5) 3.2 Reference Documents Technical Specifications 3.4.4 QUESTION 11
From the given statements select the one that correctly describes the operational leakage allowed from the reactor coolant system in MODE 1.
Reactor Coolant System operational LEAKAGE shall be limited to:
_____ A. 5 gpm TOTAL LEAKAGE.
_____ B. 2 gpm Pressure Boundary LEAKAGE.
_____ C. 25 gpm TOTAL LEAKAGE averaged over the previous [[estimated NRC review hours::24 hours]] and  5 gpm                  increase in unidentified LEAKAGE in th e previous 12 hour period.
_____ D. 25 gpm TOTAL LEAKAGE averaged over the previous [[estimated NRC review hours::24 hours]] and  2 gpm                  increase in unidentified LEAKAGE in th e previous 24 hour period.
Correct Answer :  D 25 gpm TOTAL LEAKAGE averag ed over the previous [[estimated NRC review hours::24 hours]] and 2 gpm increase in unidentified LEAKAGE in the previous 24 hour period. Per LCO 3.4.4, RCS Operational Leakage. Plausible Distractors:
A is plausible, 5 gpm is the UNIDENTIFIED Leakage Limit.
A is plausible, 5 gpm is the UNIDENTIFIED Leakage Limit.
B is plausible, NO pressure boundary leakage is permitted.
B is plausible, NO pressure boundary leakage is permitted.
C is plausible, if UNIDENTIFIED Leakage Limit is confused with INCREASE Limit.
C is plausible, if UNIDENTIFIED Leakage Limit is confused with INCREASE Limit.
Objective Link: QC-OP-725-0100-0101  
Objective Link: QC-OP-725-0100-0101
 
2006 Fermi-2 NRC RO License Exam - Retake RO 15 Tier 1 K/A Number 295006 Statement 2.4.4 IR 4 Origin N Source Question N/A LOK H (2RI) Grp 1 10 CFR 55.41(b) 10 LOD (1-5) 2.8 Reference Documents 20.125.01, Rev 22        20.125.01


Bases, Rev 0 QUESTION 12  
2006 Fermi-2 NRC RO License Exam - Retake RO      Tier          K/A Number        Statement      IR    Origin  Source Question 15        1              295006            2.4.4        4      N    N/A LOK      Grp        10 CFR 55.41(b) 10    LOD (1-5)    Reference Documents H (2RI)      1                                  2.8      20.125.01, Rev 22    20.125.01 Bases, Rev 0 QUESTION 12 The plant is operating at 100% power when the following occur:
 
* Generator Megawatts indicates 1030 Mwe (lowering).
The plant is operating at 100% pow er when the following occur:
* Generator Megawatts indicat es 1030 Mwe (lowering).
* 4D108, CONDENSER PRESSURE HIGH, alarms.
* 4D108, CONDENSER PRESSURE HIGH, alarms.
* 6D16, OFF GAS SYS MN CONDENSER PRESSURE HIGH, alarms.
* 6D16, OFF GAS SYS MN CONDENSER PRESSURE HIGH, alarms.
* Main Condenser Pressure is 2.5 psia (rising).  
* Main Condenser Pressure is 2.5 psia (rising).
 
How should the operator respond to these conditions?
How should the operator respond to these conditions?  
_____ A.       START a Mechanical Vacuum Pump.
 
_____ B.       SWAP operating Steam Jet Air Ejectors.
_____ A.
_____ C.       PLACE the Reactor Mode Switch in SHUTDOWN.
START a Mechanical Vacuum Pump.
_____ D.       PERFORM a Rapid Power Reduction per 23.623. Reactor Manual Control System.
_____ B.
Correct Answer : C 20.125.01, Loss of Condenser Vacuum, Override directs the Mode Switch be placed in SHUTDOWN when condenser vacuum is 2.5 psia.
SWAP operating Steam Jet Air Ejectors.
 
_____ C.
PLACE the Reactor Mode Switch in SHUTDOWN.
 
_____ D.
PERFORM a Rapid Power Reduction per 23.623. "Reactor Manual Control     System".  
 
Correct Answer : C 20.125.01, "Loss of Condenser Vacuum", Override directs the Mode Swit ch be placed in SHUTDOWN when condenser vacuum is 2.5 psia.
Plausible Distractors:
Plausible Distractors:
A is plausible, this is permitted ONLY < 5% Reactor Power. B is plausible, ADDITIONAL SJAEs may be started, SWAPPING is not procedurally permitted.  
A is plausible, this is permitted ONLY < 5% Reactor Power.
 
B is plausible, ADDITIONAL SJAEs may be started, SWAPPING is not procedurally permitted.
D is plausible, 20.125.01 Subsequent Action C states, If condenser vacuum cannot be maintained in the specified band, then a Rapid Power Reduction is required IAW 23.623, "Reactor Manual Control System".
D is plausible, 20.125.01 Subsequent Action C states, If condenser vacuum cannot be maintained in the specified band, then a Rapid Power Reduction is required IAW 23.623, Reactor Manual Control System.
Objective Link: SS-OP-802-2001-RO-0001  
Objective Link: SS-OP-802-2001-RO-0001
 
2006 Fermi-2 NRC RO License Exam - Retake RO 16 Tier 1 K/A Number 295016 Statement AK2.01 IR 4.4 Origin N Source Question N/A LOK F (S) Grp 1 10 CFR 55.41(b) 8 LOD (1-5) 3.6 Reference Documents ST-OP-315-0044-001
 
QUESTION 13 
 
Which one of the following correctly identifies the RCIC controls or indications available at BOTH the Main Control Room AND the Remote Shutdown Panel?
 
_____ A. RCIC Pump Flow indication.
_____ B. RCIC Pump Discharge Pressure indication.
 
_____ C. E5150-F010, RCIC Pump CST Suction Isolation Valve, control pushbuttons.
 
_____ D. RCIC Pump Flow controller with Manual and Automatic Setpoint Adjustments.


Correct Answer : A RCIC Pump Flow indication exists at both locations.
2006 Fermi-2 NRC RO License Exam - Retake RO      Tier        K/A Number          Statement      IR    Origin  Source Question 16        1            295016              AK2.01      4.4        N    N/A LOK      Grp      10 CFR 55.41(b) 8      LOD (1-5)    Reference Documents F (S)      1                                  3.6      ST-OP-315-0044-001 QUESTION 13 Which one of the following correctly identifies the RCIC controls or indications available at BOTH the Main Control Room AND the Remote Shutdown Panel?
Plausible Distractors: ALL liste d indications and controls exist in the Main Control Room.
_____ A.      RCIC Pump Flow indication.
_____ B.      RCIC Pump Discharge Pressure indication.
_____ C.      E5150-F010, RCIC Pump CST Suction Isolation Valve, control pushbuttons.
_____ D.      RCIC Pump Flow controller with Manual and Automatic Setpoint Adjustments.
Correct Answer : A RCIC Pump Flow indication exists at both locations.
Plausible Distractors: ALL listed indications and controls exist in the Main Control Room.
B is plausible, E51-R609, RCIC Pump Discharge Pressure exists ONLY in the Main Control Room.
B is plausible, E51-R609, RCIC Pump Discharge Pressure exists ONLY in the Main Control Room.
C is plausible, E5150-F010, RCIC Pump CST Suc tion Isolation Valve co ntrol exists ONLY in the Main Control Room.  
C is plausible, E5150-F010, RCIC Pump CST Suction Isolation Valve control exists ONLY in the Main Control Room.
 
D is plausible, E51-K615, RCIC Pump Flow Controller with Manual and Automatic setpoint adjustments exists ONLY in the Main Control Room.
D is plausible, E51-K615, RCIC Pump Flow Cont roller with Manual and Automatic setpoint adjustments exists ONLY in the Main Control Room.
Objective Link: ST-OP-315-0044-A013
Objective Link: ST-OP-315-0044-A013  


2006 Fermi-2 NRC RO License Exam - Retake RO 17 Tier 1 K/A Number 295018 Statement AK1.01 IR 3.5 Origin N Source Question N/A LOK H (2RI/ 3PEO) Grp 1 10 CFR 55.41(b) 10 LOD (1-5) 3.0 Reference Documents 20.127.01, Rev 27 QUESTION 14  
2006 Fermi-2 NRC RO License Exam - Retake RO       Tier         K/A Number           Statement    IR    Origin  Source Question 17        1            295018               AK1.01     3.5     N     N/A LOK       Grp     10 CFR 55.41(b) 10     LOD (1-5)   Reference Documents H (2RI/      1                                  3.0     20.127.01, Rev 27 3PEO)
 
QUESTION 14 The plant is operating at 100% power with the following conditions:
The plant is operating at 100% power with the following conditions:
* RBCCW Heat Exchangers are experiencing fouling.
* RBCCW Heat Exchangers are experiencing fouling.
* 2D120, RBCCW HX DISCH TEMPERATURE HIGH/LOW, alarms.
* 2D120, RBCCW HX DISCH TEMPERATURE HIGH/LOW, alarms.
* RBCCW Heat Exchanger Outlet Te mperature is 95 &deg;F (rising).
* RBCCW Heat Exchanger Outlet Temperature is 95 &deg;F (rising).
* RBCCW Cooling CANNOT be restored.  
* RBCCW Cooling CANNOT be restored.
 
If this trend continues, which one of the following will AUTOMATICALLY occur?
If this trend continues, which one of the following will AUTOMATICALLY occur?
_____ A.       Reactor Water Cleanup Pumps will TRIP on Low Flow.
 
_____ B.       Fuel Pool Cooling and Cleanup Pump will TRIP on Low Flow.
_____ A. Reactor Water Cleanup Pumps will TRIP on Low Flow.
_____ C.       Reactor Recirculation Pumps will TRIP on High Motor Winding Temperature.
_____ B. Fuel Pool Cooling and Cleanup Pump will TRIP on Low Flow.
_____ D.       High Pressure Coolant Injection System will ISOLATE on High Area Temperature.
_____ C. Reactor Recirculation Pumps will TRIP on High Motor Winding Temperature.
Correct Answer : A Justification: When NRHX High Inlet Temperature is > 140&deg;F, G3352-F119, RWCU Supply Suction Isolation Valve automatically closes. This will cause the operating RWCU Pump to TRIP on Low Flow (< 70 gpm).
_____ D. High Pressure Coolant Injection System will ISOLATE on High Area   Temperature.  
Plausible Distractors:
B is plausible, FPCCU is an RBCCW Load, but FPCCU Pumps have no Low Flow Trip.
C is plausible, RR Pumps are RBCCW Loads, but have no High Motor Winding Temperature Trip. There is a High Recirc Motor Generator Air Temperature Trip.
D is plausible, T4100-B022, HPCI Pump Room Cooler receives cooling from RBCCW, but is supplemented by EECW following a complete loss of RBCCW. No steam leak indications, for HPCI, are given in the stem and HPCI is not running to add heat to the room.
Objective Link: ST-OP-315-0067-B004


Correct Answer :  A Justification:  When NRHX High Inlet Temp erature is > 140&deg;F, G3352-F119, RWCU Supply Suction Isolation Valve automatically closes. This will cause the operating RWCU Pump to TRIP on Low Flow (< 70 gpm).
2006 Fermi-2 NRC RO License Exam - Retake RO       Tier         K/A Number           Statement      IR    Origin  Source Question 18        1            295019               AK3.01         3.3     B     N/A LOK       Grp       10 CFR 55.41(b) 5       LOD (1-5)     Reference Documents H        1                                    3.25       20.129.01, Rev 25; 23.129, Rev 75 (3SPK)
Plausible Distractors:
QUESTION 15 A loss of offsite power has occurred. Power has been restored to ALL Division 1 Buses.
B is plausible, FPCCU is an RBCCW Load, but FPCCU Pumps have no Low Flow Trip. C is plausible, RR Pumps are RBCCW Loads, but have no High Motor Winding Temperature Trip. There is a High Recirc Motor Generator Air Temperature Trip. D is plausible, T4100-B022, HPCI Pump Room Cooler receives cooling from RBCCW, but is supplemented by EECW following a complete loss of RBCCW. No steam leak indications, for HPCI, are given in the stem and HPCI is not running to add heat to the room.
Objective Link:  ST-OP-315-0067-B004 2006 Fermi-2 NRC RO License Exam - Retake RO 18 Tier 1 K/A Number 295019 Statement AK3.01 IR 3.3 Origin B Source Question N/A LOK H (3SPK) Grp 1 10 CFR 55.41(b) 5 LOD (1-5) 3.25 Reference Documents 20.129.01, Rev 25; 23.129, Rev 75 QUESTION 15 A loss of offsite power has occurred. Power has been restored to ALL Division 1 Buses.
* The West Station Air Compressor is operating.
* The West Station Air Compressor is operating.
* Division 1 Control Air Compressor is running, system pressure is 100 psig.
* Division 1 Control Air Compressor is running, system pressure is 100 psig.
* Division 2 Control Air Compressor failed to start.
* Division 2 Control Air Compressor failed to start.
* Division 2 NIAS Header Pre ssure is 50 psig and steady.
* Division 2 NIAS Header Pressure is 50 psig and steady.
Per 20.129.01, "Loss of Station and/or Control Air", wh at action is necessary to ensure the Div 2 Non-Interruptible Air System supply is available for continued use?  
Per 20.129.01, Loss of Station and/or Control Air, what action is necessary to ensure the Div 2 Non-Interruptible Air System supply is available for continued use?
 
_____ A.       Cross-tie NIAS with Division 1 supplying.
_____ A. Cross-tie NIAS with Division 1 supplying.
_____ B.       DEPRESS the OPEN pushbutton for P5000-F403, IAS to Div 2 NIAS Isolation Valve.
 
_____ C.       Place the P5000-F403, IAS to Div 2 NIAS Isolation Valve, keylock switch in OVRD, valve will re-open.
_____ B. DEPRESS the OPEN pushbutton for P5000-F403, IAS to Div 2 NIAS Isolation Valve. _____ C. Place the P5000-F403, IAS to Div 2 NIAS Isolation Valve, keylock switch in OVRD, valve will re-open.  
_____ D.       OPEN P5000- F440, Div 1 Control Air Isolation Valve, AND P5000- F441, Div 2 Control Air Isolation Valve.
 
Correct Answer : A Justification: Cross-tie divisions will restore air pressure to Div 2 NIAS.
_____ D. OPEN P5000- F440, Div 1 Control Air Isolation Valve, AND P5000- F441, Div 2 Control Air Isolation Valve.  
 
Correct Answer : A Justification: Cross-tie divisions wi ll restore air pressure to Div 2 NIAS.
Plausible Distractors :
Plausible Distractors :
Associated with other actions listed in 20.129.01, Loss of Station an d/or Control Air. Place the keylock control switch on Panel H11-P807 fo r P5000-F403, IAS to Div 2 NIAS Iso Vlv to OVRD. overrides closure on LOOP or LO CA. P5000-F403 opens or stays open only when Control air pressure is above 80 psig. The valve lineup in D will cross tie NIAS but is not in accordance with plant procedure. Crosstie occurs down stream of Receiver check valves.
Associated with other actions listed in 20.129.01, Loss of Station and/or Control Air. Place the keylock control switch on Panel H11-P807 for P5000-F403, IAS to Div 2 NIAS Iso Vlv to OVRD. overrides closure on LOOP or LOCA. P5000-F403 opens or stays open only when Control air pressure is above 80 psig. The valve lineup in D will cross tie NIAS but is not in accordance with plant procedure. Crosstie occurs down stream of Receiver check valves.
2006 Fermi-2 NRC RO License Exam - Retake Objective Link:  LP-OP-315-0171-C001
 
2006 Fermi-2 NRC RO License Exam - Retake RO 19 Tier 1 K/A Number 295021 Statement AA1.05 IR 3.0 Origin M Source Question EQ-OP-802-2001-
 
000-0001-002 LOK F (1P) Grp 1 10 CFR 55.41(b) 10 LOD (1-5) 2.9 Reference Documents 20.205.01, Rev. 18


QUESTION 16
2006 Fermi-2 NRC RO License Exam - Retake Objective Link: LP-OP-315-0171-C001


The plant has been recently shutdown for a Refueling Outage, with the following conditions:
2006 Fermi-2 NRC RO License Exam - Retake RO      Tier        K/A Number          Statement    IR    Origin    Source Question 19        1            295021            AA1.05      3.0      M      EQ-OP-802-2001-000-0001-002 LOK      Grp      10 CFR 55.41(b) 10    LOD (1-5)    Reference Documents F (1P)      1                                  2.9      20.205.01, Rev. 18 QUESTION 16 The plant has been recently shutdown for a Refueling Outage, with the following conditions:
* The Plant is in MODE 4.
* The Plant is in MODE 4.
* Reactor Coolant Temperature is 120&#xba;F.
* Reactor Coolant Temperature is 120&#xba;F.
* Decay Heat temperature input is equivalent to a Heat Up Rate (HUR) of 2&#xba;F/min.
* Decay Heat temperature input is equivalent to a Heat Up Rate (HUR) of 2&#xba;F/min.
* RHR Pump "C" is operating in Shutdown Cooling.
* RHR Pump C is operating in Shutdown Cooling.
* Div 2 RHR has been isolated, per a Safety Tagging Record (STR), and is draining.
* Div 2 RHR has been isolated, per a Safety Tagging Record (STR), and is draining.
* Reactor Water Level is 230 inches.
* Reactor Water Level is 230 inches.
* Reactor Pressure is 0 psig.
* Reactor Pressure is 0 psig.
RHR Pump "C" trips due to a closure of E1150-F008, RHR SDC Ot bd Suction Isol Valve, and the valve cannot be re-opened electrically or manually.
RHR Pump C trips due to a closure of E1150-F008, RHR SDC Otbd Suction Isol Valve, and the valve cannot be re-opened electrically or manually.
 
Which of the following actions is required under these conditions?
Which of the following actions is required under these conditions?  
_____ A.       Start ONE Core Spray Pump.
 
_____ B.       Start ONE Reactor Recirculation Pump.
_____ A. Start ONE Core Spray Pump.
_____ C.       Start BOTH Control Rod Drive Hydraulic Pumps.
 
_____ D.       Shift Fuel Pool Cooling and Cleanup to the Reactor Well.
_____ B. Start ONE Reactor Recirculation Pump.  
Correct Answer : B 20.205.01 Condition H requires starting a Reactor Recirculation Pump when SDC cannot be restored in either loop.
 
_____ C. Start BOTH Control Rod Drive Hydraulic Pumps.
_____ D. Shift Fuel Pool Cooling and Cleanup to the Reactor Well.  
 
Correct Answer : B 20.205.01 Condition H requires starting a Reactor Recirculation Pump wh en SDC cannot be restored in either loop.
Plausible Distractors:
Plausible Distractors:
A is plausible, a Core Spray Pump is used to raise Water Level in preparation for Refuel Operations, with SDC in service and is also used as an Alternate Decay Heat Removal System (Both pumps).
A is plausible, a Core Spray Pump is used to raise Water Level in preparation for Refuel Operations, with SDC in service and is also used as an Alternate Decay Heat Removal System (Both pumps).
2006 Fermi-2 NRC RO License Exam - Retake C is plausible, will raise RPV Water Level for natural circulation, but does not procedurally mitigate Loss of SDC.
2006 Fermi-2 NRC RO License Exam - Retake C is plausible, will raise RPV Water Level for natural circulation, but does not procedurally mitigate Loss of SDC.
D is plausible, if the Reactor Head were rem oved (MODE 5), this would be the correct action.
D is plausible, if the Reactor Head were removed (MODE 5), this would be the correct action.
Objective Link: ST-OP-315-0041-C012 Source Question showing MODIFICATIONS
Objective Link: ST-OP-315-0041-C012 Source Question showing MODIFICATIONS The plant is in Mode 4. The following conditions exist: - MODIFIED Division 1 RHR.Shutdown Cooling (SDC)
Division 2 RHR.NOT available. - MODIFIED Reactor Pressure Vessel (RPV) level230 inches RPV pressure.0 psig Division 1 RHR tripped and can NOT be restarted. - MODIFIED What action will the Reactor Operator be directed to perform? - MODIFIED A Start Reactor Recirculation pumps B Raise RPV pressure - MODIFIED C Lower RPV level - MODIFIED D Shift Fuel Pool Cleaning to the Reactor Well


The plant is in Mode 4. Th e following conditions exist: - MODIFIED
2006 Fermi-2 NRC RO License Exam - Retake RO     Tier         K/A Number         Statement      IR    Origin    Source Question 20        1              295023           AA2.01       3.6     B       Clinton 1/15/2004 NRC Exam LOK     Grp       10 CFR 55.41(b) 7     LOD (1-5)     Reference Documents F (1I)      1                                2.7       3D35, Rev 13 QUESTION 17 A Refueling Accident in the Reactor Cavity resulted in the following conditions:
 
Division 1 RHR----------------.Shutdown Cooling (SDC)
Division 2 RHR----------------.NOT available. - MODIFIED Reactor Pressure Vessel (RPV) level--------230 inches RPV pressure-----------------.0 psig
 
Division 1 RHR tripped a nd can NOT be restarted. - MODIFIED
 
What action will the Reactor Operator be directed to perform? - MODIFIED
 
A Start Reactor Recirculation pumps
 
B Raise RPV pressure - MODIFIED C Lower RPV level - MODIFIED D Shift Fuel Pool Cleaning to the Reactor Well
 
2006 Fermi-2 NRC RO License Exam - Retake RO 20 Tier 1 K/A Number 295023 Statement AA2.01 IR 3.6 Origin B Source Question Clinton 1/15/2004 NRC Exam LOK F (1I) Grp 1 10 CFR 55.41(b) 7 LOD (1-5) 2.7 Reference Documents 3D35, Rev 13 QUESTION 17  
 
A Refueling Accident in the Reactor Cavity resulted in the following conditions:
* 3D31, DIV 1 / 2 FP VENT EXH RADN MONITOR UPSCALE, alarms.
* 3D31, DIV 1 / 2 FP VENT EXH RADN MONITOR UPSCALE, alarms.
* 3D35, DIV 1 / 2 FP VENT EXH RADN MONITOR UPSCALE TRIP, alarms.
* 3D35, DIV 1 / 2 FP VENT EXH RADN MONITOR UPSCALE TRIP, alarms.
* 17D14, DIV 1 / 2 SGTS AUTO START, alarms.
* 17D14, DIV 1 / 2 SGTS AUTO START, alarms.
For the given conditions, Reactor Building HVAC Isolation Dampers     (1)     and the Reactor Building HVAC Supply and Exhaust Fans     (2)     .
For the given conditions, Reactor Building HVAC Isolation Dampers       (1)   and the Reactor Building HVAC Supply and Exhaust Fans (2) .
(1)           (2)  
(1)                             (2)
 
_____ A.           ISOLATE                             TRIP
_____ A. ISOLATE                   TRIP  
_____ B.           ISOLATE                 CONTINUE TO OPERATE
 
_____ C.       REMAIN OPEN                           TRIP
_____ B. ISOLATE           CONTINUE TO OPERATE
_____ D.       REMAIN OPEN                 CONTINUE TO OPERATE Correct Answer : A A is correct, RBHVAC Dampers ISOLATE, RB HVAC fans TRIP, and the respective division of SGTS AUTO STARTS, when a FP Vent Exhaust Rad Monitor Upscale Trip occurs.
_____ C. REMAIN OPEN       TRIP
_____ D. REMAIN OPEN CONTINUE TO OPERATE  
 
Correct Answer : A A is correct, RBHVAC Dampers ISOLATE, RB HVAC fans TRIP, and the respective division of SGTS AUTO STARTS, when a FP Vent E xhaust Rad Monitor Upscale Trip occurs.
Plausible Distractors:
Plausible Distractors:
B is incorrect, fans TRIP.  
B is incorrect, fans TRIP.
 
C is incorrect, RBHVAC/Secondary Containment Dampers ISOLATE. Dampers remaining open is plausible if SGTS operation misconception of common flowpath.
C is incorrect, RBHVAC/Secondary Containment Dampers ISOLATE. Dampers remaining open is plausible if SGTS operation misconception of common flowpath.
D is incorrect, fans TRIP, RBHVAC/secondary Containment Dampers ISOLATE. Dampers remaining open is plausible if SGTS operation misconception of common flowpath.
D is incorrect, fans TRIP, RBHVAC/secondary Containment Dampers ISOLATE. Dampers remaining open is plausible if SGTS operation misconception of common flowpath.
Objective Link: ST-OP-315-0066-A017  
Objective Link: ST-OP-315-0066-A017
 
2006 Fermi-2 NRC RO License Exam - Retake RO 70 Tier 2 K/A Number 239001 Statement A3.01 IR 4.2 Origin M Source Question  Fermi-2 2006 NRC Exam  LOK H (3PEO) Grp 2 10 CFR 55.41(b) 7 LOD (1-5) 3.4 Reference Documents 20.109.02 Bases, Rev 0 QUESTION 18 


The plant is operating at 85% power, when the IN SERVICE Pressure Regulator fails HIGH.
2006 Fermi-2 NRC RO License Exam - Retake RO      Tier          K/A Number          Statement    IR  Origin    Source Question 70        2              239001              A3.01      4.2    M      Fermi-2 2006 NRC Exam LOK      Grp        10 CFR 55.41(b) 7      LOD (1-5)    Reference Documents H        2                                    3.4      20.109.02 Bases, Rev 0 (3PEO)
With NO Operator Actions, which of the following correctly describes the effect of this failure?  
QUESTION 18 The plant is operating at 85% power, when the IN SERVICE Pressure Regulator fails HIGH.
 
With NO Operator Actions, which of the following correctly describes the effect of this failure?
_____ A.
_____ A.       ONLY an automatic Reactor Scram occurs.
ONLY an automatic Reactor Scram occurs.  
_____ B.       A Reactor Scram AND a Group 1 Isolation occurs.
 
_____ C.       Pressure Control swaps to the BACKUP Pressure Regulator AND Reactor Pressure RISES by 3 psig.
_____ B. A Reactor Scram AND a Group 1 Isolation occurs.  
_____ D.       Pressure Control swaps to the BACKUP Pressure Regulator AND Reactor Pressure LOWERS by 3 psig.
 
Correct Answer : B 52 Manifold Pressure Transmitter failure HIGH causes the Pressure Regulator to OPEN Turbine Control Valves. This LOWERS Main Steam Line Pressure, at 756 psig, a Group 1 Isolation occurs due to Low Main Steam Line Pressure, which causes a Reactor Scram.
_____ C. Pressure Control swaps to the BACKUP Pressure Regulator AND Reactor   Pressure RISES by 3 psig.
 
_____ D. Pressure Control swaps to the BACKUP Pressure Regulator AND Reactor   Pressure LOWERS by 3 psig.
 
Correct Answer : B 52 Manifold Pressure Transmitter failure HIGH causes the Pressure Regulator to OPEN Turbine Control Valves. This LOWERS Main Steam Line Pressure, at 756 psig, a Group 1 Isolation occurs due to Low Main Steam Line Pressure, which causes a Reactor Scram.
Plausible Distractors:
Plausible Distractors:
A is plausible, if Group 1 Is olation is not known, Rapid RPV Pressure reduction may cause SWELL, which causes a Level 8 Turbine Trip and a Reactor Scram ONLY. C is plausible, this resembles a Pressure Regulator Failure / Automatic Transfer. D is plausible, this resembles a Pressure Regulator Failure / Automatic Transfer.
A is plausible, if Group 1 Isolation is not known, Rapid RPV Pressure reduction may cause SWELL, which causes a Level 8 Turbine Trip and a Reactor Scram ONLY.
Objective Link: ST-OP-315-0045-A016 Source Question:  
C is plausible, this resembles a Pressure Regulator Failure / Automatic Transfer.
 
D is plausible, this resembles a Pressure Regulator Failure / Automatic Transfer.
The plant is operating at 85%
Objective Link: ST-OP-315-0045-A016 Source Question:
power, when the IN SERVICE 52 inch Manifold Pressure Transmitter Output Signal fails HIGH.
The plant is operating at 85% power, when the IN SERVICE 52 inch Manifold Pressure Transmitter Output Signal fails HIGH.
2006 Fermi-2 NRC RO License Exam - Retake Based on this failure, what action(s) will the operator perform and why? (MODIFICATION)
 
A. Perform rapid power reduction to reduce power and pressure. (MODIFICATION)
B. Ensure backup pressure regulator takes control to maintain pressure. (MODIFICATION) C. Transfer to backup pressure transmitter to prevent excessive cooldown (MODIFICATION)
D. Place the Mode Switch in SHUTDOWN and trip the main turbine bypass valves to prevent excessive cooldown. (MODIFICATION)


2006 Fermi-2 NRC RO License Exam - Retake RO 12 Tier 1 K/A Number 295003 Statement AK3.05 IR 3.7 Origin N Source Question N/A LOK H (2RI) Grp 1 10 CFR 55.41(b)10 LOD (1-5) 2.5 Reference Documents 4D132, Rev 7, 20.300.Offsite, Rev 6 QUESTION 19                      PRA sensitive issue - 8/2003 Loss of Grid Event
2006 Fermi-2 NRC RO License Exam - Retake Based on this failure, what action(s) will the operator perform and why? (MODIFICATION)
A. Perform rapid power reduction to reduce power and pressure.
(MODIFICATION)
B. Ensure backup pressure regulator takes control to maintain pressure.
(MODIFICATION)
C. Transfer to backup pressure transmitter to prevent excessive cooldown (MODIFICATION)
D. Place the Mode Switch in SHUTDOWN and trip the main turbine bypass valves to prevent excessive cooldown.
(MODIFICATION)


The plant is operating at 90% power when the following occurs:
2006 Fermi-2 NRC RO License Exam - Retake RO      Tier          K/A Number          Statement    IR    Origin  Source Question 12        1              295003            AK3.05      3.7    N      N/A LOK      Grp      10 CFR 55.41(b)10        LOD (1-5)    Reference Documents H (2RI)      1                                  2.5      4D132, Rev 7, 20.300.Offsite, Rev 6 QUESTION 19                    PRA sensitive issue - 8/2003 Loss of Grid Event The plant is operating at 90% power when the following occurs:
* 345kV and 120kV mat voltages begin lowering.
* 345kV and 120kV mat voltages begin lowering.
* 4D132, GENERATOR FREQUENCY HIGH / LOW, alarms.
* 4D132, GENERATOR FREQUENCY HIGH / LOW, alarms.
Line 428: Line 309:
* 345 kV BUS 302 POWER ON light is OFF.
* 345 kV BUS 302 POWER ON light is OFF.
* R14-R833, SS Xfmr # 65 Secondary Volt Indicator, reads zero volts.
* R14-R833, SS Xfmr # 65 Secondary Volt Indicator, reads zero volts.
* R14-R835, SS Xfmr # 65 Secondary Volt Indicator, reads zero volts.  
* R14-R835, SS Xfmr # 65 Secondary Volt Indicator, reads zero volts.
With these conditions, which one of the following actions is required?
_____ A.      Place the Reactor Mode Switch in SHUTDOWN due to a COMPLETE loss of Offsite Power.
_____ B.      Manually start and load ALL Emergency Diesel Generators due to loss of Offsite Power to BOTH divisions of ESF Buses.
_____ C.      Place the Reactor Mode Switch in SHUTDOWN due to loss of Offsite Power to ONLY ONE division of ESF Buses AND half of the BOP Buses.
_____ D.      Verify automatic start and loading of Emergency Diesel Generators 11 AND 12 due to loss of Offsite Power source to ONLY ONE division of ESF Buses.
Correct Answer : A Stem conditions indicate complete Loss of Offsite Power, 20.300.Offsite Immediate Action requires placing Reactor Mode Switch in SHUTDOWN.


With these conditions, which one of the following actions is required? 
2006 Fermi-2 NRC RO License Exam - Retake Plausible Distractors:
 
B is plausible, it is required to verify automatic EDG starts. It is not appropriate to manually start EDGs.
_____ A. Place the Reactor Mode Switch in SHUTDOWN due to a COMPLETE loss of Offsite Power.
C is plausible, if power was lost to only the 345kV system, ONE Division of ESF Buses and Half of the BOP Buses would be lost. Mode switch to shutdown is required.
_____ B. Manually start and load ALL Emergency Diesel Generators due to loss of Offsite Power to BOTH divisions of ESF Buses.
 
_____ C. Place the Reactor Mode Switch in SHUTDOWN due to loss of Offsite Power to ONLY ONE division of ESF Buses AND half of the BOP Buses. 
 
_____ D. Verify automatic start and loading of Emergency Diesel Generators 11 AND 12    due to loss of Offsite Power source to ONLY ONE division of ESF Buses.
 
Correct Answer :  A Stem conditions indicate complete Loss of Offsite Power, 20.300.Offsite Immediate Action requires placing Reactor Mode Switch in SHUTDOWN.
2006 Fermi-2 NRC RO License Exam - Retake Plausible Distractors:   B is plausible, it is required to verify automatic EDG starts. It is not appropriate to manually start EDGs.  
 
C is plausible, if power was lost to only the 345kV system, ONE Division of ESF Buses and Half of the BOP Buses would be lost.
Mode switch to shutdown is required.
D is plausible, if power were lost to only the 120 kV system, ONE Division of ESF Buses would be affected.
D is plausible, if power were lost to only the 120 kV system, ONE Division of ESF Buses would be affected.
Objective Link: SS-OP-802-2001-RO-0002  
Objective Link: SS-OP-802-2001-RO-0002
 
2006 Fermi-2 NRC RO License Exam - Retake RO 21 Tier 1 K/A Number 295024 Statement 2.2.22 IR 3.4 Origin N Source Question N/A LOK H (2DS) Grp 1 10 CFR 55.41(b) 9 LOD (1-5) 3.75 Reference Documents Technical Specification 3.6.1.4 29.100.01 Sheet 2, Rev 9, Primary Containment Control.
 
QUESTION 20


In Mode 1, the UPPER LIMIT for the DRYWELL PRESSURE LCO is     (1)   the value which requires entry into Emergency Operating Procedures (EOPs).  
2006 Fermi-2 NRC RO License Exam - Retake RO      Tier          K/A Number        Statement    IR    Origin  Source Question 21        1              295024            2.2.22      3.4    N      N/A LOK      Grp      10 CFR 55.41(b) 9        LOD (1-5)    Reference Documents H        1                                  3.75      Technical Specification 3.6.1.4 (2DS)                                                    29.100.01 Sheet 2, Rev 9, Primary Containment Control.
 
QUESTION 20 In Mode 1, the UPPER LIMIT for the DRYWELL PRESSURE LCO is                   (1)   the value which requires entry into Emergency Operating Procedures (EOPs).
The Required Action Completion Time to restore Drywell Pressure within limits is     (2)   .
The Required Action Completion Time to restore Drywell Pressure within limits is     (2) .
(1)   (2)    
(1)                   (2)
 
_____ A.           BELOW             IMMEDIATELY
_____ A. BELOW IMMEDIATELY
_____ B.           BELOW               within 1 hour
_____ B. BELOW     within 1 hour  
_____ C.           ABOVE             IMMEDIATELY
 
_____ D.           ABOVE               within 1 hour Correct Answer : D ABOVE is correct LCO is 2.0 psig, EOP Entry is 1.68 psig Within 1 hour is the correct Completion Time for 3.6.1.4 Plausible Distractors:
_____ C. ABOVE IMMEDIATELY
A is plausible, if either EOP Entry Condition or LCO is not known. IMMEDIATELY is plausible.
_____ D. ABOVE     within 1 hour  
 
Correct Answer : D ABOVE is correct LCO is 2.0 psig, EOP Entry is 1.68 psig Within 1 hour is the correct Completion Time for 3.6.1.4 Plausible Distractors:
A is plausible, if either EOP Entry C ondition or LCO is not known. IMMEDIATELY is plausible.
B is plausible, if either EOP Entry Condition or LCO is not known.
B is plausible, if either EOP Entry Condition or LCO is not known.
C is plausible, Required Action Completion Time is unknown, IMMEDIATELY is plausible.
C is plausible, Required Action Completion Time is unknown, IMMEDIATELY is plausible.
Objective Link: LP-OP-804-0002 2006 Fermi-2 NRC RO License Exam - Retake RO 22 Tier 1 K/A Number 295025 Statement EK1.06 IR 3.5 Origin N Source Question N/A LOK H (3PEO) Grp 1 10 CFR 55.41(b) 10 LOD (1-5) 3.1 Reference Documents 23.201 Rev. 24
Objective Link: LP-OP-804-0002


QUESTION 21  
2006 Fermi-2 NRC RO License Exam - Retake RO      Tier          K/A Number          Statement    IR    Origin    Source Question 22        1              295025            EK1.06      3.5      N      N/A LOK      Grp        10 CFR 55.41(b) 10      LOD (1-5)    Reference Documents H        1                                    3.1      23.201 Rev. 24 (3PEO)
 
QUESTION 21 Following a Reactor Scram, the following conditions exist:
Following a Reactor Scram, the following conditions exist:
* BOTH Bypass Valves have failed closed.
* BOTH Bypass Valves have failed closed.
* RPV Water Level is being maintained by the North Reactor Feed Pump.
* RPV Water Level is being maintained by the North Reactor Feed Pump.
* MANUAL Safety Relief Valve operation is in progress.
* MANUAL Safety Relief Valve operation is in progress.
* The Drywell is being vented to lower Drywell Pressure.
* The Drywell is being vented to lower Drywell Pressure.
Under these conditions, Reactor Water Level should be maintained___________________.  
Under these conditions, Reactor Water Level should be maintained___________________.
 
_____ A.       at 173 to avoid a Reactor Feed Pump Trip
_____ A. at 173" to avoid a Reactor Feed Pump Trip
_____ B.       at 197 to avoid a Reactor Feed Pump Trip
 
_____ C.       at 197 to avoid a Drywell Vent path isolation
_____ B. at 197" to avoid a Reactor Feed Pump Trip  
_____ D.       at 214 to avoid a Drywell Vent path isolation Correct Answer : B Precaution 3.5 states: Reactor Water Level should be as near to normal level as possible during manual SRV operation to prevent inadvertent Reactor Hi Level trips due to swell.
 
This condition results in Reactor Feed Pump Trips.
_____ C. at 197" to avoid a Dr ywell Vent path isolation
_____ D. at 214" to avoid a Dr ywell Vent path isolation  
 
Correct Answer : B Precaution 3.5 states: Reactor Water Level should be as near to normal level as possible during manual SRV operation to prevent inadvertent Reactor Hi Level trips due to swell. This condition results in Reactor Feed Pump Trips.
Plausible Distractors:
Plausible Distractors:
A is plausible, if procedural precaution is not known.  
A is plausible, if procedural precaution is not known.
 
C is plausible, if effect of Reactor Pressure induced Reactor Level response from SRV operation is not known. Reactor Low Level Trips result in Drywell Vent Path Isolation..
C is plausible, if effect of Reactor Pressure induced Reactor Level response from SRV operation is not known. Reactor Low Level Trips result in Drywell Vent Path Isolation.. D is plausible, if procedural precaution and the effect of Reactor Pressure induced Reactor Level response from SRV operation is not known.
D is plausible, if procedural precaution and the effect of Reactor Pressure induced Reactor Level response from SRV operation is not known.
Objective Link: ST-OP-315-0005-001-C005 2006 Fermi-2 NRC RO License Exam - Retake RO 23 Tier 1 K/A Number 295026 Statement EK2.03 IR 3.2 Origin B Source Question VY 2002 NRC Exam LOK F (1B) Grp 1 10 CFR 55.41(b) 10 LOD (1-5) 3.4 Reference Documents BWROG EPG /SAG B-7-24 29.100.01 Sheet 2  step TWT-5 QUESTION 22
Objective Link: ST-OP-315-0005-001-C005
 
If Torus Temperature or RPV Pressure cannot be maintained below the Heat Capacity Limit, 29.100.01 Sheet 2, "Primary Containment Control", requires Emergency Depressurization. 
 
This action is performed to avoid ____________.
 
_____ A. loss of all RPV Level instruments after RPV Emergency Depressurization
 
_____ B. damaging SRV downstream piping during RPV Emergency Depressurization


_____ C. overpressurizing the Primary Containment during RPV Emergency Depressurization  
2006 Fermi-2 NRC RO License Exam - Retake RO      Tier          K/A Number          Statement    IR    Origin  Source Question 23        1              295026            EK2.03      3.2    B      VY 2002 NRC Exam LOK      Grp      10 CFR 55.41(b) 10      LOD (1-5)    Reference Documents F (1B)      1                                  3.4      BWROG EPG /SAG B-7-24 29.100.01 Sheet 2 step TWT-5 QUESTION 22 If Torus Temperature or RPV Pressure cannot be maintained below the Heat Capacity Limit, 29.100.01 Sheet 2, Primary Containment Control, requires Emergency Depressurization.
 
This action is performed to avoid ____________.
_____ D. excessive hydrodynamic loading on Downcomer piping during RPV Emergency   Depressurization  
_____ A.      loss of all RPV Level instruments after RPV Emergency Depressurization
 
_____ B.      damaging SRV downstream piping during RPV Emergency Depressurization
Correct Answer : C The Heat Capacity Temperature Limit (HCTL) is the highest suppression pool temperature from which emergency RPV depressurization will not raise Suppression chamber pressure above Primary Containment Pressure Limit.
_____ C.       overpressurizing the Primary Containment during RPV Emergency Depressurization
_____ D.       excessive hydrodynamic loading on Downcomer piping during RPV Emergency Depressurization Correct Answer : C The Heat Capacity Temperature Limit (HCTL) is the highest suppression pool temperature from which emergency RPV depressurization will not raise Suppression chamber pressure above Primary Containment Pressure Limit.
Plausible Distractors:
Plausible Distractors:
A is plausible, High Drywell Temperature challenges RPV Level Instrumentation, addressed in same EOP.  
A is plausible, High Drywell Temperature challenges RPV Level Instrumentation, addressed in same EOP.
 
B is plausible, High Torus Level challenges SRV Tailpipe Limit, addressed in same EOP.
B is plausible, High Torus Level challenges SRV Tailpipe Limit, addressed in same EOP. D is plausible, Hydrodynamic loading on downcomers is not addressed by HCTL.
D is plausible, Hydrodynamic loading on downcomers is not addressed by HCTL.
Objective Link: LP-OP-802-3004-0009 2006 Fermi-2 NRC RO License Exam - Retake RO 7 Tier 3 K/A Number Generic Statement 2.3.4 IR 2.5 Origin N Source Question N/A LOK H  (3SPK)  10 CFR 55.41(b) 12 LOD (1-5) 3.5 Reference Documents EP-201-03 Rev 8, Section 6.2
Objective Link: LP-OP-802-3004-0009
 
QUESTION 23


Given the following conditions:
2006 Fermi-2 NRC RO License Exam - Retake RO      Tier        K/A Number            Statement      IR    Origin  Source Question 7        3            Generic                2.3.4      2.5      N    N/A LOK                10 CFR 55.41(b) 12        LOD (1-5)    Reference Documents H                                              3.5      EP-201-03 Rev 8, Section 6.2 (3SPK)
QUESTION 23 Given the following conditions:
* An accident has occurred which requires life saving measures.
* An accident has occurred which requires life saving measures.
* Radiation levels in the area of the injured person are 20,000 mrem/hr.
* Radiation levels in the area of the injured person are 20,000 mrem/hr.
* Emergency exposure TEDE (Whole Body) limit for life saving operations has been authorized per EP-201-03, "Variances From Routine Radiological Practice and Procedures During an Emergency".  
* Emergency exposure TEDE (Whole Body) limit for life saving operations has been authorized per EP-201-03, Variances From Routine Radiological Practice and Procedures During an Emergency.
 
The MAXIMUM stay time for a rescuer under these circumstances is:
The MAXIMUM stay time for a rescuer under these circumstances is:  
_____ A.       15 minutes
 
_____ B.       60 minutes
_____ A. 15 minutes
_____ C.       75 minutes
_____ B. 60 minutes
_____ D.       150 minutes Correct Answer : C 25 Rem = 25,000 mrem/20,000 mrem/hr = 75minutes Plausible Distractors:
 
_____ C. 75 minutes  
 
_____ D. 150 minutes  
 
Correct Answer : C 25 Rem = 25,000 mrem/20,000 mrem/hr = 75minutes Plausible Distractors:
A is plausible, 5,000 mrem / 20,000 = 15 minutes.
A is plausible, 5,000 mrem / 20,000 = 15 minutes.
B is plausible, 20,000 mrem / 20,000 mrem/hr = 60 minutes.
B is plausible, 20,000 mrem / 20,000 mrem/hr = 60 minutes.
D is plausible, 50,000 mrem / 20,000 mrem/hr = 150 minutes.
D is plausible, 50,000 mrem / 20,000 mrem/hr = 150 minutes.
Objective Link: LP-GN-508-0001-A015  
Objective Link: LP-GN-508-0001-A015
 
2006 Fermi-2 NRC RO License Exam - Retake RO 25 Tier 1 K/A Number 295030 Statement EA1.01 IR 3.6 Origin B Source Question  Fermi-2 2001 NRC Exam LOK H (3SPR) Grp 1 10 CFR 55.41(b) 10 LOD (1-5) 3.5 Reference Documents 29.100.01 Sheet 6 Curves and
 
Cautions Provide RCIC, HPCI, CS, and RHR NPSH Curves and CS, RHR Vortex


Curves QUESTION 24  
2006 Fermi-2 NRC RO License Exam - Retake RO      Tier        K/A Number            Statement    IR  Origin  Source Question 25        1            295030              EA1.01      3.6      B    Fermi-2 2001 NRC Exam LOK      Grp      10 CFR 55.41(b) 10      LOD (1-5)    Reference Documents H        1                                  3.5      29.100.01 Sheet 6 Curves and (3SPR)                                                    Cautions Provide RCIC, HPCI, CS, and RHR NPSH Curves and CS, RHR Vortex Curves QUESTION 24 The following plant conditions exist following a LOCA event:
 
* Torus Water Temperature is 180 &deg;F (stable).
The following plant conditions exist following a LOCA event:
* Torus Water Temperature is 180  
&deg;F (stable).
* Torus Water Level is -30 (minus 30) inches (stable).
* Torus Water Level is -30 (minus 30) inches (stable).
* Torus Pressure is 0 psig (stable).
* Torus Pressure is 0 psig (stable).
* Reactor Pressure is 70 psig (stable).
* Reactor Pressure is 70 psig (stable).
Which one of the following describes ACCEPTABLE conditions for the following pumps being used for RPV Level control?  
Which one of the following describes ACCEPTABLE conditions for the following pumps being used for RPV Level control?
 
_____ A.       RCIC operation at 600 gpm.
_____ A. RCIC operation at 600 gpm.  
_____ B.       HPCI operation at 4500 gpm.
 
_____ C.       Single pump LPCI Flow of 12,500 gpm.
_____ B. HPCI operation at 4500 gpm.  
_____ D.       Total Core Spray Loop Flow of 7000 gpm.
 
Correct Answer : D CSS NPSH Limit is ~7,600 gpm at -30 (minus 30) inches Torus Level.
_____ C. Single pump LPCI Flow of 12,500 gpm.
_____ D. Total Core Spray Loop Flow of 7000 gpm.  
 
Correct Answer : D CSS NPSH Limit is ~7,600 gpm at -30 (minus 30) inches Torus Level.
Plausible Distractors:
Plausible Distractors:
A is plausible, RCIC Pump is restricted to 450 gpm NPSH Limit.
A is plausible, RCIC Pump is restricted to 450 gpm NPSH Limit.
B is plausible, HPCI Turbine has isolated on Low Steam Pressure and flow is limited to 3700 gpm.
B is plausible, HPCI Turbine has isolated on Low Steam Pressure and flow is limited to 3700 gpm.
C is plausible, RHR Loop Flow over 12,000 gpm exceeds the NPSH Limit.
C is plausible, RHR Loop Flow over 12,000 gpm exceeds the NPSH Limit.
2006 Fermi-2 NRC RO License Exam - Retake Objective Link:  ST-OP-802-3002-001-007


2006 Fermi-2 NRC RO License Exam - Retake RO 63 Tier 2 K/A Number 264000 Statement K4.01 IR 3.5 Origin B Source Question  Fermi-2 2003 NRC Exam LOK H (3PEO) Grp 1 10 CFR 55.41(b) 7 LOD (1-5) 3.2 Reference Documents 23.307, Rev 90 QUESTION 25
2006 Fermi-2 NRC RO License Exam - Retake Objective Link: ST-OP-802-3002-001-007


The plant is in a refueling outage. EDG 11 is running in parallel with Offsite power. 64B-B6, the Normal Offsite Power Feed Breaker, opens spuriously with no faults indicated. How will this affect EDG operation?  
2006 Fermi-2 NRC RO License Exam - Retake RO      Tier        K/A Number          Statement    IR    Origin    Source Question 63        2              264000              K4.01      3.5      B      Fermi-2 2003 NRC Exam LOK      Grp      10 CFR 55.41(b) 7      LOD (1-5)  Reference Documents H        1                                  3.2      23.307, Rev 90 (3PEO)
 
QUESTION 25 The plant is in a refueling outage. EDG 11 is running in parallel with Offsite power. 64B-B6, the Normal Offsite Power Feed Breaker, opens spuriously with no faults indicated. How will this affect EDG operation?
_____ A. The EDG will continue to run, Bus 64B will load shed.  
_____ A.       The EDG will continue to run, Bus 64B will load shed.
 
_____ B.       The EDG will continue to run, ALL EDG trips will remain active.
_____ B. The EDG will continue to run, ALL EDG trips will remain active.
_____ C.       The EDG will continue to run, ONLY essential trips will remain active.
_____ C. The EDG will continue to run, ONLY essential trips will remain active.
_____ D.       The EDG will trip on under frequency and restart, Bus 64B will load shed, and vital loads will sequence back on.
_____ D. The EDG will trip on under frequency and restart, Bus 64B will load shed,   and vital loads will sequence back on.  
Correct Answer : C Whenever an EDG output breaker is closed, the Undervoltage Relaying for the associated 4160V ESF busses is disabled. The EDG non-essential trips are removed whenever the Normal Feed Breaker (B6, C6, E6, and F6) and Maintenance Tie Breaker (B9, C9, E9, and F9) for that bus are open.
 
Correct Answer : C Whenever an EDG output breaker is closed, the Undervoltage Relaying for the associated 4160V ESF busses is disabled. The EDG non-essential trips are removed whenever the Normal Feed Breaker (B6, C6, E6, and F6) and Maintenance Tie Breaker (B9, C9, E9, and F9) for that bus are open.
Plausible Distractors:
Plausible Distractors:
A is plausible, no Load Shed will occur because Undervoltage Relaying for the associated 4160V ESF buses is disabled.
A is plausible, no Load Shed will occur because Undervoltage Relaying for the associated 4160V ESF buses is disabled.
B is plausible, non-essential trips are removed when the B6 an d Maintenance Tie Breaker are open.
B is plausible, non-essential trips are removed when the B6 and Maintenance Tie Breaker are open.
D is plausible for a LOOP, non-essential trips are removed when the B6 and Maintenance Tie Breaker are open. No Load Shed will occur because Undervoltage Relaying for the associated 4160V ESF buses is disabled.
D is plausible for a LOOP, non-essential trips are removed when the B6 and Maintenance Tie Breaker are open. No Load Shed will occur because Undervoltage Relaying for the associated 4160V ESF buses is disabled.
Objective Link: ST-OP-315-0065-A016  
Objective Link: ST-OP-315-0065-A016


2006 Fermi-2 NRC RO License Exam - Retake RO 27 Tier 1 K/A Number 295037 Statement 2.4.6 IR 3.1 Origin B Source Question  Fermi-2 2003 NRC Exam LOK F (1P) Grp 1 10 CFR 55.41(b) 10 LOD (1-5) 2.9 Reference Documents 29.ESP.11 Rev 8 QUESTION 26  
2006 Fermi-2 NRC RO License Exam - Retake RO     Tier         K/A Number             Statement      IR    Origin    Source Question 27        1              295037                 2.4.6       3.1       B     Fermi-2 2003 NRC Exam LOK     Grp       10 CFR 55.41(b) 10       LOD (1-5)     Reference Documents F (1P)      1                                      2.9       29.ESP.11 Rev 8 QUESTION 26 The plant is in an ATWS. An RO has been assigned to perform 29.ESP.11, Defeat of RPV Level 1 and High Rad MSIV and Main Steam Line Drain Valve Isolation Signals.
 
Prior to completing the procedure, the MSIVs automatically close on RPV Level.
The plant is in an ATWS. An RO has been assigned to perform 29.ESP.11, "Defeat of RPV Level 1 and High Rad MSIV and Main Steam Line Drain Valve Isolation Signals". Prior to completing the procedure, the MSIVs automatically close on RPV Level.  
Where does the assigned operator perform the defeats for this procedure, and how will the MSIVs be affected by performing this procedure after the MSIVs are closed?
 
_____ A.      H11-P601 and H11-P602, MSIVs automatically open after a 30 second time delay.
Where does the assigned operator perform the defeats for this procedure, and how will the MSIVs be affected by performing this procedure after the MSIVs are closed?  
_____ B.      RR H11-P609 and RR H11-P611, MSIVs automatically open with no operator action.
_____ C.      RR H11-P609 and RR H11-P611, MSIVs can be manually opened after the isolation signal is reset.
_____ D.      H11-P601 and H11-P602, MSIVs can be manually opened by depressing the Inbd and Otbd MSIV OPEN pushbuttons.
Correct Answer : C Defeats are accomplished with jumper installation at P609 and P611, in the Relay Room.
Isolation Reset pushbuttons are performed on P601 and P602, in the Main Control Room.
Isolation Reset is required to facilitate reopening MSIVs.
Plausible Distractors:
A is plausible, there is no automatic MSIV open function. Could be confused for loss of air operation.
B is plausible, correct defeat location, no automatic MSIV open function following an isolation candidate could confuse with loss of air operation.
D is plausible, defeat location is incorrect, reset of isolation signal is required to reopen.
Objective Link: LP-OP-802-3006-0018


_____ A. H11-P601 and H11-P602, MSIVs automatically open after a 30 second time  delay.
2006 Fermi-2 NRC RO License Exam - Retake RO       Tier         K/A Number           Statement      IR    Origin  Source Question 28        1              295038             EK1.02       4.2     M     N/A LOK       Grp     10 CFR 55.41(b) 10     LOD (1-5)     Reference Documents F (1B)      1                                  2.7       BWROG EPG Appendix B Section 6 QUESTION 27 During an accident condition involving fuel damage and a radiation release, the following conditions exist:
_____ B. RR H11-P609 and RR H11-P611, MSIVs automatically open with no operator  action. 
 
_____ C. RR H11-P609 and RR H11-P611, MSIVs can be manually opened after the  isolation signal is reset.
_____ D. H11-P601 and H11-P602, MSIVs can be manually opened by depressing the  Inbd and Otbd MSIV OPEN pushbuttons.
 
Correct Answer :  C Defeats are accomplished with jumper installation at P609 and P611, in the Relay Room. Isolation Reset pushbuttons are performed on P601 and P602, in the Main Control Room. Isolation Reset is required to facilitate reopening MSIVs.
Plausible Distractors:    A is plausible, there is no automatic MSIV open function. Could be confused for loss of air operation.
B is plausible, correct defeat location, no automatic MSIV open functi on following an isolation candidate could confuse w ith loss of air operation.
D is plausible, defeat location is incorrect, reset of isolation signa l is required to reopen.
Objective Link:  LP-OP-802-3006-0018 2006 Fermi-2 NRC RO License Exam - Retake RO 28 Tier 1 K/A Number 295038 Statement EK1.02 IR 4.2 Origin M Source Question N/A LOK F (1B) Grp 1 10 CFR 55.41(b) 10 LOD (1-5) 2.7 Reference Documents BWROG EPG Appendix B Section 6 QUESTION 27  
 
During an accident condition i nvolving fuel damage and a radiation release, the following conditions exist:
* Mode Switch is in SHUTDOWN.
* Mode Switch is in SHUTDOWN.
* Reactor Power is 12%.
* Reactor Power is 12%.
* Div 1 AXM Channel 4 is 6.0 microCi/cc (rising).
* Div 1 AXM Channel 4 is 6.0 microCi/cc (rising).
* Div 2 AXM Channel 4 is 5.8 microCi/cc (rising).
* Div 2 AXM Channel 4 is 5.8 microCi/cc (rising).
Why do the EPG BASES permit bypass of the MSIV Level 1 and High Radiation interlocks in this condition?  
Why do the EPG BASES permit bypass of the MSIV Level 1 and High Radiation interlocks in this condition?
 
_____ A.       To prevent a threat to Drywell integrity from Hydrogen accumulation.
_____ A. To prevent a threat to Drywell integrity from Hydrogen accumulation.
_____ B.       To prevent power oscillations from exceeding the Steam Flow capability of Safety Relief Valves.
 
_____ C.       To allow the Main Condenser in conjunction with the Off Gas System to reduce the dose to the public.
_____ B. To prevent power oscillations from exceeding the Steam Flow capability of Safety   Relief Valves.  
_____ D.       To allow Main Steam Line Radiation Monitor data to be used to improve the accuracy of Offsite Dose Calculations.
 
Correct Answer : C BWROG EPG states; If, instead, high radiation interlocks are not bypassed and steam is discharged through the SRVs into the suppression pool, radionuclides not scrubbed in the pool will accumulate in the containment atmosphere, from which they may escape due to normal containment leakage. Even if processed prior to release by the Standby Gas Treatment System, the public dose will be higher than if these radionuclides were retained in or processed by the Offgas System.
_____ C. To allow the Main Condenser in conjunction with the Off Gas System to reduce   the dose to the public.  
 
_____ D. To allow Main Steam Line Radiation Monitor data to be used to improve the   accuracy of Offsite Dose Calculations.  
 
Correct Answer : C BWROG EPG states; "If, instead, high radiati on interlocks are not bypassed and steam is discharged through the SRVs into the suppressi on pool, radionuclides not scrubbed in the pool will accumulate in the containment atmosphere, from which they may escape due to normal containment leakage. Even if processed prior to release by the Standby Gas Treatment System, the public dose will be higher than if these radionuclides were retained in or processed by the Offgas System.
2006 Fermi-2 NRC RO License Exam - Retake Plausible Distractors:    A is plausible, Fuel Damage may be accompanied by Hydrogen generation, which can be a long term containment threat.
B is plausible, other ATWS mitigation actions reduce the probability of fuel damage from core power oscillations.
 
D is plausible, Main Steam Line Radiation Mo nitor readings are NOT used for offsite dose calculations.
Objective Link:  LP-OP-802-3003-0013 Source Question:
 
During an accident condition i nvolving fuel damage and a radiation release, the following conditions exist:


2006 Fermi-2 NRC RO License Exam - Retake Plausible Distractors:
A is plausible, Fuel Damage may be accompanied by Hydrogen generation, which can be a long term containment threat.
B is plausible, other ATWS mitigation actions reduce the probability of fuel damage from core power oscillations.
D is plausible, Main Steam Line Radiation Monitor readings are NOT used for offsite dose calculations.
Objective Link: LP-OP-802-3003-0013 Source Question:
During an accident condition involving fuel damage and a radiation release, the following conditions exist:
Mode Switch is in SHUTDOWN.
Mode Switch is in SHUTDOWN.
Reactor Power is 15%. (MINOR MODIFICATION) Div 1 AXM Channel 4 is 5.0 microCi/
Reactor Power is 15%. (MINOR MODIFICATION)
cc (rising). (MINOR MODIFICATION) Div 2 AXM Channel 4 is 4.8 microCi/
Div 1 AXM Channel 4 is 5.0 microCi/cc (rising). (MINOR MODIFICATION)
cc (rising). (MINOR MODIFICATION)  
Div 2 AXM Channel 4 is 4.8 microCi/cc (rising). (MINOR MODIFICATION)
 
Why do the EPG BASES permit bypass of the MSIV Level 1 and High Radiation interlocks in this condition?
Why do the EPG BASES permit bypass of the MSIV Level 1 and Hi gh Radiation interlocks in this condition?  
A. The Turbine Building has a hold up time equivalent to SGTS.
 
(SIGNIFICANT MODIFICATION)
A. The Turbine Building has a hold up time equivalent to SGTS. (SIGNIFICANT MODIFICATION)  
 
B. The Main Condenser in conjunction with the Off Gas system will result in a lower dose to the public.
B. The Main Condenser in conjunction with the Off Gas system will result in a lower dose to the public.
C. The walls of the Main Steam piping and Main Condenser provide       one tenth-thickness for gamma attenuation.
C. The walls of the Main Steam piping and Main Condenser provide one tenth-thickness for gamma attenuation.
(SIGNIFICANT MODIFICATION)
D. The Main Condenser provides a long hold up time by entrainment in the condensate and will result in a lower dose to the public.
(SIGNIFICANT MODIFICATION)
(SIGNIFICANT MODIFICATION)
D. The Main Condenser provides a long hold up time by entrainment in the
condensate and will result in a lower dose to the public.  (SIGNIFICANT MODIFICATION)
2006 Fermi-2 NRC RO License Exam - Retake RO 29 Tier 1 K/A Number 600000 Statement AK2.04 IR 2.5 Origin N Source Question N/A LOK F (1P) Grp 1 10 CFR 55.41(b) 10 LOD (1-5) 2.75 Reference Documents 20.000.18 Rev 39 Action B1 QUESTION 28


Per 20.000.18, "Control of the Plant from the Dedicat ed Shutdown Panel", when a fire develops causing spurious plant equipment operations, the Reactor Protection System Scram Relays are placed in a scram condition by ________________.  
2006 Fermi-2 NRC RO License Exam - Retake RO      Tier        K/A Number            Statement  IR      Origin  Source Question 29        1              600000              AK2.04    2.5        N    N/A LOK      Grp      10 CFR 55.41(b) 10        LOD (1-5)  Reference Documents F (1P)      1                                    2.75    20.000.18 Rev 39 Action B1 QUESTION 28 Per 20.000.18, Control of the Plant from the Dedicated Shutdown Panel, when a fire develops causing spurious plant equipment operations, the Reactor Protection System Scram Relays are placed in a scram condition by ________________.
 
_____ A.       depressing the RPS Manual Scram Pushbuttons
_____ A. depressing the RPS Manual Scram Pushbuttons  
_____ B.       opening the RPS MG Set Power Supply Breakers
 
_____ C.       placing the Reactor Mode Switch in SHUTDOWN
_____ B. opening the RPS MG Set Power Supply Breakers
_____ D.       placing the APRM Channel Keylock Switches in INOP Correct Answer : A 20.000.18 states, IF Control Room inaccessible as a result of a fire OR actual spurious operation of components or failures of components occur, depress Manual Scram Pushbuttons. Depressing the Manual Scram Pushbuttons is the only manual action performed in the control room that is given credit in the NRC guidance document Generic Letter 86-10, Implementation of Fire Protection Requirements.
_____ C. placing the Reactor Mode Switch in SHUTDOWN
_____ D. placing the APRM Channe l Keylock Switches in INOP Correct Answer : A 20.000.18 states, "IF Control Room inaccessible as a result of a fire OR actual spurious operation of components or failures of components occur, depress Manual Scram Pushbuttons.Depressing the Manual Scram Pushbuttons is the only manual action performed in the control room that is given credit in the NRC guidance docume nt Generic Letter 86-10, Implementation of Fire Protection Requirements.
Plausible Distractors:
Plausible Distractors:
B is plausible, will cause a Reactor Scram and PCIS Isolations, NOT procedurally directed. C is plausible, will cause a Reactor Scram and defeat the MSL Low Pressure Group 1 Isolation, NOT procedurally directed.
B is plausible, will cause a Reactor Scram and PCIS Isolations, NOT procedurally directed.
D is plausible, will cause a Reactor Scram, NOT procedurally directed. Plausibility is due to 20.000.19, "Shutdown From Outside The Control Room" directs this method in non-fire situations.
C is plausible, will cause a Reactor Scram and defeat the MSL Low Pressure Group 1 Isolation, NOT procedurally directed.
Objective Link: SS-OP-802-2001-001  
D is plausible, will cause a Reactor Scram, NOT procedurally directed. Plausibility is due to 20.000.19, Shutdown From Outside The Control Room directs this method in non-fire situations.
 
Objective Link: SS-OP-802-2001-001
2006 Fermi-2 NRC RO License Exam - Retake RO 45 Tier 2 K/A Number 215004 Statement 2.1.30 IR 3.9 Origin B Source Question  Limerick 2002 NRC Exam LOK H (2DR) Grp 1 10 CFR 55.41(b) 6 LOD (1-5) 2.3 Reference Documents 23.602, Rev 26
 
QUESTION 29


Plant conditions are as follows:
2006 Fermi-2 NRC RO License Exam - Retake RO      Tier          K/A Number        Statement      IR    Origin  Source Question 45        2              215004            2.1.30      3.9      B    Limerick 2002 NRC Exam LOK      Grp        10 CFR 55.41(b) 6    LOD (1-5)      Reference Documents H        1                                  2.3      23.602, Rev 26 (2DR)
QUESTION 29 Plant conditions are as follows:
* MODE 2, Reactor Startup is in progress.
* MODE 2, Reactor Startup is in progress.
* RPS Nuclear Instrumentation shorting links are installed.
* RPS Nuclear Instrumentation shorting links are installed.
Line 659: Line 477:
* The reactor is CRITICAL.
* The reactor is CRITICAL.
* ALL IRMs are on Range 2.
* ALL IRMs are on Range 2.
SRMs currently indicate:  
SRMs currently indicate:
"A" SRM - 1.4 x 105 cps "B" SRM - 1.1 x 105 cps "C" SRM - 9.2 x 104 cps "D" SRM - 2.3 x 105 cps Per 23.602, Source Range Monitoring System, which one of the following describes the proper positioning of the SRMs and the correct method for withdrawal using the "DRIVE OUT" pushbutton based on the above conditions?
SRM position                    DRIVE OUT Pushbutton
_____ A.        Withdrawn to maintain      Depress and hold for continuous SRM withdrawal.
100 to 105 cps.
_____ B.        Withdrawn to maintain      Depress and release for continuous SRM 100 to 105 cps.            withdrawal.
_____ C.        Fully withdrawn without    Depress and hold for continuous SRM withdrawal.
regard to count rate.
_____ D.      Fully withdrawn without      Depress and release for continuous SRM regard to count rate.        withdrawal.


"A" SRM - 1.4 x 10 5 cps  "B" SRM - 1.1 x 10 5 cps  "C" SRM - 9.2 x 10 4 cps "D" SRM - 2.3 x 10 5 cps Per 23.602, "Source Range Monitoring System", which one of the following describes the proper positioning of the SRMs and the correct method for withdrawal using the "DRIVE OUT" pushbutton based on the above conditions? 
2006 Fermi-2 NRC RO License Exam - Retake Correct Answer : A 23.602 requires maintaining SRMs on scale between 100 and 105 cps. The procedure specifies depressing and holding the DRIVE OUT pushbutton to withdraw detectors.
 
Plausible Distractors:
SRM position      DRIVE OUT Pushbutton
B is plausible, potential misconception - DRIVE IN seals in, requiring only a momentary depress of the pushbutton.
 
_____ A. Withdrawn to maintain Depress and hold for continuous SRM withdrawal. 100 to 10 5 cps. _____ B. Withdrawn to maintain Depre ss and release for continuous SRM        100 to 10 5 cps. withdrawal.
 
_____ C. Fully withdrawn without  Depress and hold for continuous SRM withdrawal. regard to count rate.
 
_____ D. Fully withdrawn without Depr ess and release for continuous SRM    regard to count rate. withdrawal.
 
2006 Fermi-2 NRC RO License Exam - Retake Correct Answer : A 23.602 requires maintaining SRMs on scale between 100 and 10 5 cps. The procedure specifies depressing and holding the DRIVE OUT pushb utton to withdraw detectors.
Plausible Distractors: B is plausible, potential misconception - DRIVE IN seals in, requiring only a momentary depress of the pushbutton.
C is plausible, potential misconception - detectors are fully withdrawn only above the Point of Adding Heat, power is given as IRM Range 2.
C is plausible, potential misconception - detectors are fully withdrawn only above the Point of Adding Heat, power is given as IRM Range 2.
D is plausible and incorrect on BOTH of the above misconceptions.
D is plausible and incorrect on BOTH of the above misconceptions.
Objective Link: ST-OP-315-0022-A014  
Objective Link: ST-OP-315-0022-A014
 
2006 Fermi-2 NRC RO License Exam - Retake RO 30 Tier 1 K/A Number 295026 Statement EK3.04 IR 3.7 Origin B Source Question  Fermi-2 2003 NRC Exam LOK F (1B) Grp 1 10 CFR 55.41(b) 10 LOD (1-5) 2.7 Reference Documents EPG Bases B-6-68 Rev 2 QUESTION 30


The plant has experienced a full power ATWS.
2006 Fermi-2 NRC RO License Exam - Retake RO      Tier        K/A Number          Statement      IR    Origin  Source Question 30        1              295026            EK3.04      3.7      B      Fermi-2 2003 NRC Exam LOK      Grp      10 CFR 55.41(b) 10      LOD (1-5)    Reference Documents F (1B)      1                                  2.7      EPG Bases B-6-68 Rev 2 QUESTION 30 The plant has experienced a full power ATWS.
The crew failed to initiate boron injection before Torus water temperature reached the Boron Injection Initiation Temperature (BIIT).
The crew failed to initiate boron injection before Torus water temperature reached the Boron Injection Initiation Temperature (BIIT).
Alternate means to shutdown the reactor have been unsuccessful.  
Alternate means to shutdown the reactor have been unsuccessful.
 
The FIRST limit violated by delayed boron injection is the...
The FIRST limit violated by delayed boron injection is the...  
_____ A.       Heat Capacity Limit.
 
_____ B.       RPV Saturation Limit.
_____ A. Heat Capacity Limit.  
_____ C.       Primary Containment Pressure Limit.
 
_____ D.       Minimum RPV Flooding Pressure Limit.
_____ B. RPV Saturation Limit.
Correct Answer : A The basis for the BIIT is to assure Hot Shutdown Boron Weight is injected prior to exceeding the Heat Capacity Limit. The Heat Capacity Limit may be violated by delayed boron injection.
_____ C. Primary Containment Pressure Limit.
 
_____ D. Minimum RPV Flooding Pressure Limit.
 
Correct Answer : A The basis for the BIIT is to assure Hot Shutdown Boron Weight is injected prior to exceeding the Heat Capacity Limit. The Heat Capacity Limit may be violated by de layed boron injection.
Plausible Distractors:
Plausible Distractors:
B is plausible, but is simply ba sed on the properties of water. C is plausible, if ED is initiated AFTER the Heat Capacity Limit is exceeded, PCPL may be violated.  
B is plausible, but is simply based on the properties of water.
 
C is plausible, if ED is initiated AFTER the Heat Capacity Limit is exceeded, PCPL may be violated.
D is plausible, but is dependent upon (1) the Minimum SRV Reopening Pressure or (2) the lowest differential pressure between the RPV and the suppression chamber at which steam flow through the Minimum Number of SRVs Required for Emergency Depressurization is sufficient to remove all decay heat from the core.
D is plausible, but is dependent upon (1) the Minimum SRV Reopening Pressure or (2) the lowest differential pressure between the RPV and the suppression chamber at which steam flow through the Minimum Number of SRVs Required for Emergency Depressurization is sufficient to remove all decay heat from the core.
Objective Link: ST-OP-802-3002-001-01-06 2006 Fermi-2 NRC RO License Exam - Retake RO 31 Tier 1 K/A Number 295007 Statement AK3.04 IR 4 Origin N Source Question N/A LOK H (2RI/ 3PEO) Grp 2 10 CFR 55.41(b) 7 LOD (1-5) 2.4 Reference Documents 1D38, Rev 13 QUESTION  31
Objective Link: ST-OP-802-3002-001-01-06


The plant was operating at 100 % power wh en the following transient occurred:
2006 Fermi-2 NRC RO License Exam - Retake RO      Tier          K/A Number            Statement      IR    Origin Source Question 31        1              295007              AK3.04        4      N    N/A LOK      Grp    10 CFR 55.41(b) 7          LOD (1-5)      Reference Documents H (2RI/      2                                    2.4        1D38, Rev 13 3PEO)
QUESTION 31 The plant was operating at 100 % power when the following transient occurred:
* A spurious Group 1 Isolation occurred.
* A spurious Group 1 Isolation occurred.
* ALL Control Rods are fully inserted.
* ALL Control Rods are fully inserted.
Line 705: Line 516:
* NO operator actions have occurred.
* NO operator actions have occurred.
* ONE Safety Relief Valve (SRV) is open.
* ONE Safety Relief Valve (SRV) is open.
After 5 minutes, Safety Relief Valve (SRV)   (1) is open in the   (2) mode.
After 5 minutes, Safety Relief Valve (SRV) (1)       is open in the (2) mode.
(1)       (2)  
(1)                       (2)
 
_____ A.               A                       Safety
_____ A. A     Safety
_____ B.               G                       Safety
 
_____ C.               A                     Low-Low Set
_____ B. G     Safety  
_____ D.               G                     Low-Low Set Correct Answer : C Candidate must know plant response to Full Power Group 1 Isolation. This includes RPV Pressure exceeding High Pressure Scram Setpoint with an SRV Open. This activates Low-Low Set, which reduces Lift Setpoint of Lowest SRV to 1017 psig.
 
Plausible Distractors:
_____ C. A   Low-Low Set
A/B is plausible, immediately following a MSIV closure scram, these valves could be open due to exceeding their safety relief setpoints (1135 psig).
_____ D. G   Low-Low Set  
 
Correct Answer : C Candidate must know plant response to Full Po wer Group 1 Isolation. This includes RPV Pressure exceeding High Pressure Scram Setpoint with an SRV Open. This activates Low-Low Set, which reduces Lift Set point of Lowest SRV to 1017 psig.
Plausible Distractors: A/B is plausible, immediately fo llowing a MSIV closure scram, these valves could be open due to exceeding their safety re lief setpoints (1135 psig).
D is plausible, but is NOT the LOWEST Low-Low Set Lift Setpoint (1047 psig).
D is plausible, but is NOT the LOWEST Low-Low Set Lift Setpoint (1047 psig).
Objective Link: ST-OP-315-005-B003 2006 Fermi-2 NRC RO License Exam - Retake RO 32 Tier 1 K/A Number 295008 Statement AK1.02 IR 2.8 Origin M Source Question 1999 Duane Arnold NRC Exam LOK F (1D) Grp 2 10 CFR 55.41(b) 5 LOD (1-5) 2.3 Reference Documents Technical Specification Basis 3.3.2.2 QUESTION 32
Objective Link: ST-OP-315-005-B003
 
With the plant operating at 100%
power, if Feedwater Flow EXCEEDS Steam Flow, this condition may result in: 
 
_____ A. CARRYOVER, which reduces NPSH to Jet Pumps.
 
_____ B. CARRYOVER, which increases erosion of Main Turbine Blades.
_____ C. CARRYUNDER, which reduces NPSH to Reactor Recirculation Pumps.
_____ D. CARRYUNDER, which increases erosion of Steam Separators and Dryers.
 
Correct Answer :  B Candidate must diagnose a condi tion which produces a HIGH RPV Water Level and select the associated damaging mechanism and susceptible component.
Plausible Distractors: 


2006 Fermi-2 NRC RO License Exam - Retake RO      Tier        K/A Number          Statement    IR    Origin    Source Question 32        1            295008            AK1.02      2.8    M      1999 Duane Arnold NRC Exam LOK      Grp      10 CFR 55.41(b) 5      LOD (1-5)    Reference Documents F (1D)      2                                  2.3      Technical Specification Basis 3.3.2.2 QUESTION 32 With the plant operating at 100% power, if Feedwater Flow EXCEEDS Steam Flow, this condition may result in:
_____ A.        CARRYOVER, which reduces NPSH to Jet Pumps.
_____ B.        CARRYOVER, which increases erosion of Main Turbine Blades.
_____ C.      CARRYUNDER, which reduces NPSH to Reactor Recirculation Pumps.
_____ D.      CARRYUNDER, which increases erosion of Steam Separators and Dryers.
Correct Answer : B Candidate must diagnose a condition which produces a HIGH RPV Water Level and select the associated damaging mechanism and susceptible component.
Plausible Distractors:
A is plausible, CARRYOVER does not reduce NPSH to Jet Pumps (wrong effect).
A is plausible, CARRYOVER does not reduce NPSH to Jet Pumps (wrong effect).
C is plausible, CARRYUNDER (wrong mechanism) can reduce Downcomer Subcooling, which reduces NPSH to Reactor Recirculation Pumps.
C is plausible, CARRYUNDER (wrong mechanism) can reduce Downcomer Subcooling, which reduces NPSH to Reactor Recirculation Pumps.
D is plausible, Steam Separators and Dryers are designed to operate in a wet steam environment and are not susceptible to moisture erosion.
D is plausible, Steam Separators and Dryers are designed to operate in a wet steam environment and are not susceptible to moisture erosion.
Objective Link: LP-OP-804-001 Source Question:
Objective Link: LP-OP-804-001 Source Question:
One of the running Reactor Feed Pumps was inadvertently TRIPPED wh ile the plant was at 90% power. (SIGNIFICANT MODIFICATION)  
One of the running Reactor Feed Pumps was inadvertently TRIPPED while the plant was at 90% power. (SIGNIFICANT MODIFICATION) 1)Does the resultant transient result in CARRYOVER or CARRYUNDER ?
2)What is the primary concern associated with this condition?
A 1) CARRYUNDER 2) Reduction in Recirc Pump Net Positive Suction Head.
B. 1) CARRYOVER 2) Excess moisture impinging the blades of the Main Turbine.
C. 1) CARRYOVER 2) Reduction in Recirc Pump Net Positive Suction Head


1)Does the resultant transient result in CARRYOVER or CARRYUNDER ? 2)What is the primary concern a ssociated with this condition? A  1) CARRYUNDER  2) Reduction in Recirc Pump Net Positive Suction Head. B. 1) CARRYOVER    2) Excess moisture impinging the blades of the Main Turbine.
2006 Fermi-2 NRC RO License Exam - Retake D. 1) CARRYUNDER 2) Excess moisture impinging the blades of the Main Turbine
C. 1) CARRYOVER    2) Reduction in Recirc Pump Net Positive Suction Head 2006 Fermi-2 NRC RO License Exam - Retake D. 1) CARRYUNDER 2) Excess moisture im pinging the blades of the Main Turbine  


2006 Fermi-2 NRC RO License Exam - Retake RO 34 Tier 1 K/A Number 295012 Statement AK2.02 IR 3.6 Origin B Source Question  Fermi-2 2001 NRC Exam LOK F (1P) Grp 2 10 CFR 55.41(b) 10 LOD (1-5) 2.4 Reference Documents ARP 8D41 Rev 14 QUESTION 33  
2006 Fermi-2 NRC RO License Exam - Retake RO     Tier         K/A Number           Statement    IR    Origin  Source Question 34      1              295012             AK2.02     3.6     B     Fermi-2 2001 NRC Exam LOK     Grp       10 CFR 55.41(b) 10     LOD (1-5)   Reference Documents F (1P)      2                                  2.4       ARP 8D41 Rev 14 QUESTION 33 The plant is operating at full power with all DW Cooling Fans in operation. SCCW is Out of Service. Panel H11-P808 annunciator 8D41, DIV 1 DRYWELL TEMPERATURE HIGH, alarms. The operator observes that T47-R803A, Drywell Cooling System Area Temperatures Div 1, point 16 indicates 158&deg;F (alarm setpoint is 155&deg;F).
If the AVERAGE drywell temperature has risen from 132&deg;F to 135&deg;F during the last [[estimated NRC review hours::8 hours]], which one of the following actions is appropriate?
_____ A.        Start an additional RBCCW Pump.
_____ B.        Increase GSW cooling to RBCCW.
_____ C.        Manually initiate EECW and EESW Systems.
_____ D.        Enter 29.100.01 Sheet 2, Primary Containment Control.
Correct Answer : B ARP 8D41, directs starting all DW Cooling Fans (stem condition), INCREASING GSW to RBCCW HXs, and Starting RBCCW Supplemental Cooling. (stem condition)
Plausible Distractors:
A is plausible, no symptoms are given for inadequate RBCCW Cooling of RBCCW Loads.
C is plausible, EECW is not required for the given conditions.
D is plausible, Primary Containment Control EOP is entered on High Drywell Pressure (1.68 psig) or Drywell Avg Temp > 145&#xba;F. This small amount of temperature increase would not cause the PC to exceed 1.68 psig. The candidate could confuse temperature setpoint and might think pressure would increase greatly.
Objective Link: ST-OP-315-0017-C010


The plant is operating at full power with all DW Cooling Fans in operation. SCCW is Out of Service. Panel H11-P808 annunciator 8D41, DIV 1 DRYWELL TEMPERATURE HIGH, alarms. The operator observes that T47-R803A, Drywell Cooling System Area Temperatures Div 1, point 16 indicates 158
2006 Fermi-2 NRC RO License Exam - Retake RO       Tier         K/A Number           Statement    IR    Origin  Source Question 24        1            295028               EK3.01     3.6       N     N/A LOK       Grp       10 CFR 55.41(b) 10       LOD (1-5)   Reference Documents F (1B)      1                                    2.9       BWROG EPG/SAG B-7-24 EPG DIFF DOC QUESTION 34 Per 29.100.01, Sheet 2, Primary Containment Control, when Drywell Temperature cannot be restored and maintained below 340 &deg;F, what action is required, and why?
&deg;F (alarm setpoint is 155
_____ A.       Initiate Drywell Sprays to maintain RPV Water Level Instrument Accuracy.
&deg;F). If the AVERAGE drywell temperature has risen from 132
_____ B.       Emergency Depressurize because Drywell Design Temperature has been exceeded.
&deg;F to 135&deg;F during the last [[estimated NRC review hours::8 hours]], which one of the following actions is appropriate?
_____ C.       Initiate Drywell Sprays prior to reaching conditions which will result in exceeding evaporative cooling limits.
 
_____ D.       Emergency Depressurize to maintain the isolation capability of the Main Steam Isolation Valves (MSIVs).
_____ A. Start an additional RBCCW Pump.
Correct Answer : B BWROG EPG Basis is the lesser of Drywell Design Temperature or ADS Qualification Temperature, at Fermi-2, these values are BOTH 340&deg;F.
 
Plausible Distractors:
_____ B. Increase GSW cooling to RBCCW.
A is plausible, but the RPV Saturation Curve coupled with erratic level instrument behavior are the criteria for Level Unknown Emergency Depressurization - not 340&deg;F without regard to RPV Pressure. Example, DW=350&deg;F, RPV pressure = 1000 psig, SAT CURVE is not violated.
_____ C. Manually initiate EECW and EESW Systems.
C is plausible, and is the correct basis for the Drywell Spray Initiation Limit Curve, (DWSIL),
_____ D. Enter 29.100.01 Sheet 2, "Primary Containment Control".
which is also a Drywell Temperature consideration and required at lower Drywell Temperatures.
 
D is plausible, Containment Integrity is the basis, MSIVs include Outboard Valves which are not subject to DW Temperature and provide isolation capability.
Correct Answer :  B ARP 8D41, directs starting all DW Cooling Fans (stem condition), INCREASING GSW to RBCCW HXs, and Starting RBCCW Supplemental Cooling. (stem condition)
Objective Link: LP-OP-802-3004-009
Plausible Distractors: A is plausible, no symptoms are given for inadequate RBCCW Cooli ng of RBCCW Loads. C is plausible, EECW is not re quired for the given conditions. D is plausible, Primary Containment Control EOP is entered on High Drywell Pressure (1.68 psig) or Drywell Avg Temp > 145&#xba;F. This small amount of temperatur e increase would not cause the PC to exceed 1.68 psig. The candidate could confuse temperature setpoint and might think pressure would increase greatly.
Objective Link:  ST-OP-315-0017-C010 2006 Fermi-2 NRC RO License Exam - Retake RO 24 Tier 1 K/A Number 295028 Statement EK3.01 IR 3.6 Origin N Source Question N/A LOK F (1B) Grp 1 10 CFR 55.41(b) 10 LOD (1-5) 2.9 Reference Documents BWROG EPG/SAG B-7-24  
 
EPG DIFF DOC QUESTION 34  
 
Per 29.100.01, Sheet 2, "Primary Containment Control", when Drywell Temperature cannot be restored and maintained below 340  
&deg;F, what action is required, and why?  
 
_____ A. Initiate Drywell Sprays to maintain RPV Water Level Instrument Accuracy.  
 
_____ B. Emergency Depressurize because Drywell Design Temperature has been exceeded.
 
_____ C. Initiate Drywell Sprays prior to re aching conditions which will result in exceeding   evaporative cooling limits.  
 
_____ D. Emergency Depressurize to maintain the isolation capability of the Main Steam Isolation Valves (MSIVs).  
 
Correct Answer : B BWROG EPG Basis is the lesser of Drywell Design Temperature or ADS Qualification Temperature, at Fermi-2, these values are BOTH 340
&deg;F. Plausible Distractors: A is plausible, but the RPV Saturation Curve coupled with erratic level instrument behavior are the criteria for "Level Unknown" Em ergency Depressurization - not 340
&deg;F without regard to RPV Pressure. Example, DW=350
&deg;F, RPV pressure = 1000 psig, SAT CURVE is not violated.  


C is plausible, and is the correct basis for the Drywell Spray Initiation Limit Curve, (DWSIL), which is also a Drywell Temperature cons ideration and required at lower Drywell Temperatures.
2006 Fermi-2 NRC RO License Exam - Retake RO     Tier         K/A Number           Statement    IR    Origin    Source Question 35        1            295013             AA2.01       3.8     M       2001 Quad Cities NRC Exam LOK       Grp     10 CFR 55.41(b) 10     LOD (1-5)     Reference Documents F (1P)      2                                    2.5     1D61 Rev 19, 20.000.25 Rev 20 QUESTION 35 The plant is operating at 80% power when the following occurs:
 
D is plausible, Containment Integrity is the basis, MSIVs incl ude Outboard Valves which are not subject to DW Temperature a nd provide isolation capability.
Objective Link:  LP-OP-802-3004-009
 
2006 Fermi-2 NRC RO License Exam - Retake RO 35 Tier 1 K/A Number 295013 Statement AA2.01 IR 3.8 Origin M Source Question 2001 Quad Cities NRC Exam LOK F (1P) Grp 2 10 CFR 55.41(b) 10 LOD (1-5) 2.5 Reference Documents 1D61 Rev 19, 20.000.25 Rev 20 QUESTION 35
 
The plant is operating at 80% power when the following occurs:
* 1D61, SRV OPEN, alarms.
* 1D61, SRV OPEN, alarms.
* Red OPEN light for Safety Relief Valv e B2104-F013H (COP H11-P601) is LIT.
* Red OPEN light for Safety Relief Valve B2104-F013H (COP H11-P601) is LIT.
* Reactor Pressure is 1025 psig (stable).
* Reactor Pressure is 1025 psig (stable).
Given these conditions, when would the crew be REQUIRED to initiate a manual reactor scram per 20.000.25, "Faile d Safety Relief Valve" ?  
Given these conditions, when would the crew be REQUIRED to initiate a manual reactor scram per 20.000.25, Failed Safety Relief Valve ?
 
_____ A.       When Torus Water Average Temperature reaches 95&deg;F.
_____ A. When Torus Water Average Temperature reaches 95
_____ B.       When Torus Water Average Temperature reaches 110&deg;F.
&deg;F.
_____ C.       Immediately, IF the SRV CANNOT be closed with the pushbuttons.
_____ B. When Torus Water Average Temperature reaches 110
_____ D.       Immediately, IF the SRV CANNOT be closed by pulling control power fuses.
&deg;F. _____ C. Immediately, IF the SRV CANNOT be closed with the pushbuttons.
Correct Answer : B AOP 20.000.25, Failed Safety Relief Valve requires manual scram at 110&deg;F Torus Average Water Temperature.
_____ D. Immediately, IF the SRV CANNOT be closed by pulling control power fuses.  
Plausible Distractors:
 
A is plausible, EOP Entry Condition for 29.100.01, Sheet 2, Primary Containment Control.
Correct Answer : B AOP 20.000.25, Failed Safety Relief Valve requires manual scram at 110
&deg;F Torus Average Water Temperature.
Plausible Distractors:  
 
A is plausible, EOP Entry Condition for 29.100.01, Sheet 2, "Primary Containment Control".
C is plausible, 20.000.25 requires Rapid Downpower when pushbuttons fail to close the SRV.
C is plausible, 20.000.25 requires Rapid Downpower when pushbuttons fail to close the SRV.
D is plausible, 20.000.25 directs pulling control power fuses, but does not require immediate scram when this is unsuccessful.
D is plausible, 20.000.25 directs pulling control power fuses, but does not require immediate scram when this is unsuccessful.
Objective Link: SS-OP-802-2001-RO-0003 Source Question:  
Objective Link: SS-OP-802-2001-RO-0003 Source Question:
 
Unit 2 was operating at 60% power with a HPCI surveillance in progress when the following annunciator was received: (MODIFICATION)
Unit 2 was operating at 60% power with a HPCI surveillance in progress when the following annunciator was received: (MODIFICATION)
- 3A TARGET ROCK RELIEF VLV OPEN 2006 Fermi-2 NRC RO License Exam - Retake Assuming reactor pressure is normal, when would the crew be REQUIRED to initiate a manual reactor scram?
- 3A TARGET ROCK RELIEF VLV OPEN


A. When Torus Bulk Water Temperature reaches 95
2006 Fermi-2 NRC RO License Exam - Retake Assuming reactor pressure is normal, when would the crew be REQUIRED to initiate a manual reactor scram?
&deg;F. B. When Torus Bulk Water Temperature reaches 105
A. When Torus Bulk Water Temperature reaches 95&deg;F.
&deg;F. (MODIFICATION) C. Immediately AFTER verifying the safe ty relief valve (SRV) is actually open. D. Immediately, IF the SRV is actually open and it CANNOT be closed with the keylock switch. (MODIFICATION)
B. When Torus Bulk Water Temperature reaches 105&deg;F. (MODIFICATION)
C. Immediately AFTER verifying the safety relief valve (SRV) is actually open.
D. Immediately, IF the SRV is actually open and it CANNOT be closed with the keylock switch. (MODIFICATION)


2006 Fermi-2 NRC RO License Exam - Retake RO 36 Tier 1 K/A Number 295032 Statement EK2.04 IR 3.6 Origin N Source Question N/A LOK H (2RI/ 3PEO) Grp 2 10 CFR 55.41(b) 10 LOD (1-5) 3.0 Reference Documents 1D66, Rev 12 QUESTION 36  
2006 Fermi-2 NRC RO License Exam - Retake RO       Tier         K/A Number           Statement      IR    Origin  Source Question 36      1              295032             EK2.04         3.6     N     N/A LOK       Grp     10 CFR 55.41(b) 10       LOD (1-5)     Reference Documents H (2RI/    2                                    3.0         1D66, Rev 12 3PEO)
 
QUESTION 36 Following a plant transient, the following conditions exist:
Following a plant transient, th e following conditions exist:
* ALL Control Rods are fully inserted.
* ALL Control Rods are fully inserted.
* RPV Water Level is +190 inches (stable).
* RPV Water Level is +190 inches (stable).
* 1D66, STEAM LEAK DETECTION AMBIENT TEMP HIGH, alarms.
* 1D66, STEAM LEAK DETECTION AMBIENT TEMP HIGH, alarms.
* 1D70, STEAM LEAK DETECTION DIFF TEMP HIGH, alarms.
* 1D70, STEAM LEAK DETECTION DIFF TEMP HIGH, alarms.
* B21-N600, Main Steam Tunnel Ambient Temperature, reads 160
* B21-N600, Main Steam Tunnel Ambient Temperature, reads 160&deg;F.
&deg;F.
* E51-N600, RCIC Ambient (RCIC and CS Room) Temperature, reads 160&deg;F.
* E51-N600, RCIC Ambient (RCIC and CS Room) Temperature, reads 160
* E41-N600, HPCI Ambient (HPCI and CRD Pump Area) Temperature, reads 135&deg;F.
&deg;F.
With these conditions, which one of the following conditions describes the status of Primary Containment Isolation System Valves?
* E41-N600, HPCI Ambient (HPCI and CRD Pump Area) Temperature, reads 135
_____ A.      ONLY HPCI Valves have received an Isolation Signal.
&deg;F. With these conditions, which one of the following conditions describes the status of Primary Containment Isolation System Valves?  
_____ B.      ONLY RCIC Valves have received an Isolation Signal.
_____ C.      ONLY Main Steam Isolation Valves AND HPCI Valves have received an Isolation Signal.
_____ D.      ONLY Main Steam Isolation Valves AND RCIC Valves have received an Isolation Signal.
Correct Answer : B Since RCIC Equipment Room Temperature exceeds 154&deg;F, a Group 8 Isolation will occur.
Candidate must know PCIS setpoints.
Plausible Distractors:
A is wrong, HPCI Equipment Room is 135&deg;F, Group 6 occurs at 154&deg;F.
C is wrong, MSL Tunnel Temperature is 160&deg;F - Group 1 occurs at 200&deg;F, HPCI Equipment


_____ A.
2006 Fermi-2 NRC RO License Exam - Retake Room is 135&deg;F, Group 6 occurs at 154&deg;F..
ONLY HPCI Valves have received an Isolation Signal.
D is wrong,, MSL Tunnel Temperature is 160&deg;F - Group 1 occurs at 200&deg;F.
_____ B.
Objective Link: ST-OP-315-0048-B000
ONLY RCIC Valves have receiv ed an Isolation Signal.
_____ C.
ONLY Main Steam Isolation Valves AND HPCI Valves have received an  Isolation Signal.
_____ D.
ONLY Main Steam Isolation Valves AND RCIC Valves have received an  Isolation Signal. 
 
Correct Answer :  B Since RCIC Equipment Room Temperature exceeds 154&deg;F, a Group 8 Isolation will occur. Candidate must know PCIS setpoints.
Plausible Distractors:  A is wrong, HPCI Equipment Room is 135
&deg;F, Group 6 occurs at 154&deg;F. C is wrong, MSL Tunnel Temperature is 160&deg;F - Group 1 occurs at 200&deg;F, HPCI Equipment 2006 Fermi-2 NRC RO License Exam - Retake Room is 135
&deg;F, Group 6 occurs at 154&deg;F.. D is wrong,, MSL Tunnel Temperature is 160&deg;F - Group 1 occurs at 200&deg;F.
Objective Link: ST-OP-315-0048-B000 2006 Fermi-2 NRC RO License Exam - Retake RO 33 Tier 1 K/A Number 295010 Statement 2.4.31 IR 3.3 Origin N Source Question N/A LOK F (1I) Grp 2 10 CFR 55.41(b) 10 LOD (1-5) 2.2 Reference Documents ARP 3D81, Rev 11 QUESTION 37
 
The plant is operating at 100% power, when the following alarms and indications are received:
* 3D81, PRIMARY CONTAINMENT PRESSURE HIGH/LOW, alarms.
 
When Primary Containment Pressure is at the HIGH alarm setpoint, _______ should occur.
 
_____ A. NO actuations
_____ B.
ONLY a Primary Containment Isolation System (PCIS) actuation
 
_____ C.
ONLY a Reactor Scram AND Emergency Co re Cooling System actuation
_____ D. a Reactor Scram AND Emergency Core Cooling System (ECCS)
AND Primary  Containment Isolation System (PCIS) actuations
 
Correct Answer : A Annunciator Response Procedure 3D81 provide s the High (1.50 psig) and Low (0.10) setpoints. The HIGH setpoint is BELOW the 1.68 psig Reactor Scram, ECCS, and PCIS actuation setpoint.
Plausible Distractors:   


2006 Fermi-2 NRC RO License Exam - Retake RO        Tier        K/A Number          Statement    IR    Origin    Source Question 33        1            295010              2.4.31    3.3    N      N/A LOK        Grp    10 CFR 55.41(b) 10      LOD (1-5)  Reference Documents F (1I)      2                                  2.2    ARP 3D81, Rev 11 QUESTION 37 The plant is operating at 100% power, when the following alarms and indications are received:
* 3D81, PRIMARY CONTAINMENT PRESSURE HIGH/LOW, alarms.
When Primary Containment Pressure is at the HIGH alarm setpoint, _______ should occur.
_____ A.      NO actuations
_____ B.      ONLY a Primary Containment Isolation System (PCIS) actuation
_____ C.      ONLY a Reactor Scram AND Emergency Core Cooling System actuation
_____ D.      a Reactor Scram AND Emergency Core Cooling System (ECCS) AND Primary Containment Isolation System (PCIS) actuations Correct Answer : A Annunciator Response Procedure 3D81 provides the High (1.50 psig) and Low (0.10) setpoints. The HIGH setpoint is BELOW the 1.68 psig Reactor Scram, ECCS, and PCIS actuation setpoint.
Plausible Distractors:
B is plausible, PCIS actuations occurs at 1.68 psig.
B is plausible, PCIS actuations occurs at 1.68 psig.
C is plausible, Reactor Scram (RPS) trip and ECCS actuation occurs at 1.68 psig. D is plausible, Reactor Scram (RPS) trip, ECCS actuation, and PCIS actuation occurs at 1.68 psig. Objective Link: ST-OP-315-0016-B007 2006 Fermi-2 NRC RO License Exam - Retake RO 37 Tier 1 K/A Number 295034 Statement EA1.04 IR 4.1 Origin M Source Question  Fermi-2 2001 NRC Exam LOK F (1I) Grp 2 10 CFR 55.41(b) 7 LOD (1-5) 2.4 Reference Documents 3D36, Rev 13 QUESTION 38 
C is plausible, Reactor Scram (RPS) trip and ECCS actuation occurs at 1.68 psig.
D is plausible, Reactor Scram (RPS) trip, ECCS actuation, and PCIS actuation occurs at 1.68 psig.
Objective Link: ST-OP-315-0016-B007


The following actions automatically occurred:
2006 Fermi-2 NRC RO License Exam - Retake RO      Tier          K/A Number          Statement      IR    Origin  Source Question 37        1            295034              EA1.04        4.1      M    Fermi-2 2001 NRC Exam LOK      Grp        10 CFR 55.41(b) 7      LOD (1-5)      Reference Documents F (1I)      2                                    2.4        3D36, Rev 13 QUESTION 38 The following actions automatically occurred:
* Reactor Building HVAC automatically tripped.
* Reactor Building HVAC automatically tripped.
* SGTS automatically started.
* SGTS automatically started.
* Control Center HVAC automatically aligned to Recirculation Mode.
* Control Center HVAC automatically aligned to Recirculation Mode.
Which one of the following annunciators is associated with ALL of these actuations?  
Which one of the following annunciators is associated with ALL of these actuations?
 
_____ A.       3D12, DIV 1/2 OFF GAS RADN MONITOR HIGH HIGH
_____ A. 3D12, DIV 1/2 OFF GAS RADN MONITOR HIGH HIGH  
_____ B.       3D36, DIV 1/2 RB VENT EXH RADN MONITOR UPSCALE TRIP
 
_____ C.       3D46, RW BLDG VENT EXHAUST RADN MONITOR UPSCALE / INOP
_____ B. 3D36, DIV 1/2 RB VENT EXH RADN MONITOR UPSCALE TRIP
_____ D.       3D45, CONT CENTER MAKEUP AIR RADN MONITOR UPSCALE TRIP Correct Answer : B RB Vent Exhaust High Radiation Upscale Trip causes SBGT to initiate, Reactor Building HVAC fans trip and isolate, and Control Center HVAC to shift to the Recirculation Mode.
_____ C. 3D46, RW BLDG VENT EXHAUST RADN MONITOR UPSCALE / INOP
_____ D. 3D45, CONT CENTER MAKEUP AIR RADN MONITOR UPSCALE TRIP  
 
Correct Answer : B RB Vent Exhaust High Radiation Upscale Trip causes SBGT to initiate, Reactor Building HVAC fans trip and isolate, and Control Center HVAC to shift to the Recirculation Mode.
Plausible Distractors:
Plausible Distractors:
A is plausible, Off Gas exits via RB Exhaust Stack.  
A is plausible, Off Gas exits via RB Exhaust Stack.
 
C is plausible, and is expected during a RW Bldg radiation release, ONLY trips RW Bldg HVAC.
C is plausible, and is expected during a RW Bldg radiation release, ONLY trips RW Bldg HVAC.
D is plausible, and is expected during a plant radiation release, but ONLY shifts Control Center HVAC to the Recirculation Mode.
D is plausible, and is expected during a plant radiation release, but ONLY shifts Control Center HVAC to the Recirculation Mode.
Objective Link: ST-OP-315-0066-B003 Source Question:  
Objective Link: ST-OP-315-0066-B003 Source Question:
 
The following actions automatically occurred as the result of high radiation:
The following actions automatically occurred as the result of high radiation:
(MODIFICATION) 2006 Fermi-2 NRC RO License Exam - Retake
(MODIFICATION)
    - Reactor Building HVAC tripped
 
  - SGTS started
 
  - Control Center HVAC ali gned to recirculation mode
 
Based on the information provided above, CHOOSE the radiation monitor and indicated radiation level that caused the automatic actions. (MODIFICATION)


2006 Fermi-2 NRC RO License Exam - Retake
- Reactor Building HVAC tripped
- SGTS started
- Control Center HVAC aligned to recirculation mode Based on the information provided above, CHOOSE the radiation monitor and indicated radiation level that caused the automatic actions. (MODIFICATION)
A Fuel Pool Vent Exhaust = 7.3 mRem. (MODIFICATION)
A Fuel Pool Vent Exhaust = 7.3 mRem. (MODIFICATION)
B Reactor Building Vent Exhaust = 14,500 cpm. (MODIFICATION)
B Reactor Building Vent Exhaust = 14,500 cpm. (MODIFICATION)
C Turbine Building Vent Exhaust = 11,500 cpm. (MODIFICATION)
C Turbine Building Vent Exhaust = 11,500 cpm. (MODIFICATION)
D Radwaste Building Vent Exhaust = 14.5 mRem. (MODIFICATION)
D Radwaste Building Vent Exhaust = 14.5 mRem. (MODIFICATION)


2006 Fermi-2 NRC RO License Exam - Retake RO 1 Tier 3 K/A Number Generic Statement 2.1.22 IR 2.8 Origin B Source Question N/A LOK F (1D)  10 CFR 55.41(b) 10 LOD (1-5) 3.0 Reference Documents Tech Spec Table 1.1-1 QUESTION 39  
2006 Fermi-2 NRC RO License Exam - Retake RO     Tier         K/A Number           Statement      IR    Origin  Source Question 1        3            Generic             2.1.22       2.8     B     N/A LOK               10 CFR 55.41(b) 10     LOD (1-5)       Reference Documents F (1D)                                          3.0       Tech Spec Table 1.1-1 QUESTION 39 Plant conditions are as follows:
 
Plant conditions are as follows:  
 
Reactor Mode Switch is in the SHUTDOWN position.
Reactor Mode Switch is in the SHUTDOWN position.
Reactor Coolant System Temperature is 120&deg;F.  
Reactor Coolant System Temperature is 120&deg;F.
 
ALL Control Rods are fully inserted.
ALL Control Rods are fully inserted.
ALL Reactor Vessel Head Closure Bolts are NOT fully tensioned.  
ALL Reactor Vessel Head Closure Bolts are NOT fully tensioned.
 
Per Technical Specifications, which operating MODE is the plant in?
Per Technical Specifications, which operating MODE is the plant in?  
_____ A.     MODE 2 (STARTUP)
 
_____ B.     MODE 3 (HOT SHUTDOWN)
_____ A. MODE 2 (STARTUP)  
_____ C.     MODE 4 (COLD SHUTDOWN)
 
_____ D.     MODE 5 (REFUEL)
_____ B. MODE 3 (HOT SHUTDOWN)  
Correct Answer : D Per Table 1.1-1, MODE 5 (REFUEL) exists when the Reactor Mode Switch is in Shutdown or Refuel at ANY Temperature with one or more Reactor Vessel Head Closure Bolts not fully tensioned.
 
Plausible Distractors:
_____ C. MODE 4 (COLD SHUTDOWN)  
 
_____ D. MODE 5 (REFUEL)  
 
Correct Answer : D Per Table 1.1-1, MODE 5 (REFUEL) exists when the Reactor Mode Switch is in Shutdown or Refuel at ANY Temperature with one or more Reactor Vessel Head Closure Bolts not fully tensioned.
Plausible Distractors:
 
A is plausible if candidate incorrectly associates the requirements for MODE 2.
A is plausible if candidate incorrectly associates the requirements for MODE 2.
B/C is plausible if candidate does not know the allowance for the Mode Switch to be in SHUTDOWN for MODE 5.
B/C is plausible if candidate does not know the allowance for the Mode Switch to be in SHUTDOWN for MODE 5.
Objective Link: LP-OP-804-0002  
Objective Link: LP-OP-804-0002


2006 Fermi-2 NRC RO License Exam - Retake RO 38 Tier 2 K/A Number 203000 Statement K4.01 IR 4.2 Origin B Source Question N/A LOK H (2RI) Grp 1 10 CFR 55.41(b) 7 LOD (1-5) 2.8 Reference Documents 23.205, Rev 94 QUESTION 40 Two minutes after a STEAM leak develops inside the dryw ell the following conditions exist:
2006 Fermi-2 NRC RO License Exam - Retake RO       Tier         K/A Number           Statement    IR    Origin  Source Question 38        2            203000               K4.01       4.2     B     N/A LOK       Grp       10 CFR 55.41(b) 7       LOD (1-5)   Reference Documents H (2RI)      1                                  2.8       23.205, Rev 94 QUESTION 40 Two minutes after a STEAM leak develops inside the drywell the following conditions exist:
* Drywell pressure is 13 psig (rising).
* Drywell pressure is 13 psig (rising).
* Reactor pressure is 400 psig (lowering at 10 psig per minute).
* Reactor pressure is 400 psig (lowering at 10 psig per minute).
* RPV level is 170 inches (rising).
* RPV level is 170 inches (rising).
* B3105-F031B, Reactor Recirc Pump B Discharge Valve, is CLOSED.
* B3105-F031B, Reactor Recirc Pump B Discharge Valve, is CLOSED.
Recirculation Loop   (1) has been selected for injection AND on the selected loop,   (2)   . _____ A. (1) A (2) BOTH LPCI Injection Valves are OPEN
Recirculation Loop (1) has been selected for injection AND on the selected loop, (2) .
_____ B. (1) B (2) BOTH LPCI Injection Valves are OPEN
_____ A.       (1) A (2) BOTH LPCI Injection Valves are OPEN
_____ C. (1) A (2) ONE LPCI Injection Valve is CLOSED
_____ B.       (1) B (2) BOTH LPCI Injection Valves are OPEN
_____ D. (1) B (2) ONE LPCI Injection Valve is CLOSED Correct Answer : B The candidate must know that BOTH injection valves are open when RPV Pressure is < 461 psig AND that B is the default Loop Selection when NO Recirculation Loop break is sensed.
_____ C.       (1) A (2) ONE LPCI Injection Valve is CLOSED
_____ D.       (1) B (2) ONE LPCI Injection Valve is CLOSED Correct Answer : B The candidate must know that BOTH injection valves are open when RPV Pressure is < 461 psig AND that B is the default Loop Selection when NO Recirculation Loop break is sensed.
Plausible Distractors:
Plausible Distractors:
A is plausible, A Loop would be selected if the break was in B Recirculation Loop.
A is plausible, A Loop would be selected if the break was in B Recirculation Loop.
C is plausible, A Loop would be selected if the break was in B Recirculation Loop, ONE valve would be CLOSED if RPV Pressure were > 461 psig.  
C is plausible, A Loop would be selected if the break was in B Recirculation Loop, ONE valve would be CLOSED if RPV Pressure were > 461 psig.
 
D is plausible, ONE valve would be CLOSED if RPV Pressure were > 461 psig.
D is plausible, ONE valve would be CLOS ED if RPV Pressure were > 461 psig.
2006 Fermi-2 NRC RO License Exam - Retake Objective Link:  ST-OP-315-0041-B000, B003 2006 Fermi-2 NRC RO License Exam - Retake RO 39 Tier 2 K/A Number 205000 Statement K5.02 IR 2.8 Origin B Source Question N/A LOK H (2DR/3PEO)
Grp 1 10 CFR 55.41(b) 7 LOD (1-5) 2.7 Reference Documents ST-OP-315-0041 Rev 14, 23.205
 
Rev 94  QUESTION 41
 
The plant is in MODE 4 with the following conditions:
* Division 1 Residual Heat Removal (RHR) Syst em is ALIGNED in the Shutdown Cooling Mode with RHR Pump "C" in service.
* RHR Pump "C" is temporarily shutdown to perform Post Maintenance Testing and I&C SDC Surveillances. 
 
The PMT requires E1150-F004C, Division I RHR Pump C Torus Suction Isolation Valve, to be manually opened and closed using the handwheel.
 
What is the consequence of operating this valve, in this configuration?


_____ A. The Reactor Well and Fuel P ool will drain to the Torus.
2006 Fermi-2 NRC RO License Exam - Retake Objective Link: ST-OP-315-0041-B000, B003
_____ B. RHR Pump C will trip on loss of suction flow path when re-started.
_____ C. Water hammer will occur when RHR Pump C is re-started due to loss of fill and    vent. _____ D. RPV level will lower via a drain path from the Reactor Pressure Vessel to the    Torus.


Correct Answer : D Suction Path is aligned to the RPV, parallel path would be to the Torus, resulting in an inadvertent RPV drain path to the Torus.
2006 Fermi-2 NRC RO License Exam - Retake RO          Tier      K/A Number          Statement    IR    Origin  Source Question 39          2            205000            K5.02      2.8      B      N/A LOK          Grp    10 CFR 55.41(b) 7      LOD (1-5)    Reference Documents H          1                                2.7      ST-OP-315-0041 Rev 14, 23.205 (2DR/3PEO)                                                  Rev 94 QUESTION 41 The plant is in MODE 4 with the following conditions:
* Division 1 Residual Heat Removal (RHR) System is ALIGNED in the Shutdown Cooling Mode with RHR Pump C in service.
* RHR Pump C is temporarily shutdown to perform Post Maintenance Testing and I&C SDC Surveillances.
The PMT requires E1150-F004C, Division I RHR Pump C Torus Suction Isolation Valve, to be manually opened and closed using the handwheel.
What is the consequence of operating this valve, in this configuration?
_____ A.      The Reactor Well and Fuel Pool will drain to the Torus.
_____ B.      RHR Pump C will trip on loss of suction flow path when re-started.
_____ C.      Water hammer will occur when RHR Pump C is re-started due to loss of fill and vent.
_____ D.      RPV level will lower via a drain path from the Reactor Pressure Vessel to the Torus.
Correct Answer : D Suction Path is aligned to the RPV, parallel path would be to the Torus, resulting in an inadvertent RPV drain path to the Torus.
Plausible Distractors:
Plausible Distractors:
A is plausible, (MODE 5) If the RPV Head were removed, RPV was Flooded Up, and the FP Gates removed, when the Torus Suction Valve was opened - Reactor Well and Fuel Pool  
A is plausible, (MODE 5) If the RPV Head were removed, RPV was Flooded Up, and the FP Gates removed, when the Torus Suction Valve was opened - Reactor Well and Fuel Pool Level would LOWER.
 
Level would LOWER.
2006 Fermi-2 NRC RO License Exam - Retake B is plausible, if the F004 were closed (Torus Suction Valve) and eith er the F006 or F008 or F009 (SDC Suction Valves) were closed. Candidate confusion.
 
C is plausible, if the discharge side of the RH R piping were drained, but this is prevented by an installed check valve.
Objective Link:  ST-OP-315-0041-C005


2006 Fermi-2 NRC RO License Exam - Retake RO 40 Tier 2 K/A Number 206000 Statement K6.02 IR 3.3 Origin B Source Question N/A LOK F (1I) Grp 1 10 CFR 55.41(b) 7 LOD (1-5) 2.9 Reference Documents 23.202, Rev 89 QUESTION 42
2006 Fermi-2 NRC RO License Exam - Retake B is plausible, if the F004 were closed (Torus Suction Valve) and either the F006 or F008 or F009 (SDC Suction Valves) were closed. Candidate confusion.
C is plausible, if the discharge side of the RHR piping were drained, but this is prevented by an installed check valve.
Objective Link: ST-OP-315-0041-C005


Div 2 ESF DC Distribution 2PB is lost. From the following list, se lect which response contains the HPCI system steam supply valve(s) that has (have)
2006 Fermi-2 NRC RO License Exam - Retake RO      Tier        K/A Number        Statement    IR      Origin  Source Question 40        2            206000            K6.02      3.3      B      N/A LOK      Grp      10 CFR 55.41(b) 7    LOD (1-5)    Reference Documents F (1I)      1                                2.9      23.202, Rev 89 QUESTION 42 Div 2 ESF DC Distribution 2PB is lost. From the following list, select which response contains the HPCI system steam supply valve(s) that has (have) LOST power.
LOST power.
* E4150-F002, HPCI Steam Supply Inboard Isolation Valve
* E4150-F002, HPCI Steam Supply Inboard Isolation Valve
* E4150-F003, HPCI Steam Supply Outboard Isolation Valve
* E4150-F003, HPCI Steam Supply Outboard Isolation Valve
* E4150-F600, HPCI Steam Supply Outboard Isolation Bypass Valve  
* E4150-F600, HPCI Steam Supply Outboard Isolation Bypass Valve
 
_____ A.       E4150-F002, HPCI Steam Supply Inboard Isolation Valve ONLY
_____ A. E4150-F002, HPCI Steam Supply Inboard Isolation Valve ONLY
_____ B.       E4150-F003, HPCI Steam Supply Outboard Isolation Valve ONLY
_____ B. E4150-F003, HPCI Steam Supply Outboard Isolation Valve ONLY
_____ C.       BOTH E4150-F002, HPCI Steam Supply Inboard Isolation Valve AND E4150-F003, HPCI Steam Supply Outboard Isolation Valve
_____ C. BOTH E4150-F002, HPCI Steam Supply Inboard Isolation Valve AND   E4150-F003, HPCI Steam Supply Outboard Isolation Valve
_____ D.       BOTH E4150-F003, HPCI Steam Supply Outboard Isolation Valve AND E4150-F600, HPCI Steam Supply Outboard Isolation Bypass Valve Correct Answer : D Justification: E4150-F003 and E4150-F600 are powered from MCC 2PB-1.
_____ D.
Plausible Distractors A is plausible, E4150-F002 is powered from MCC 72C-3A.
BOTH E4150-F003, HPCI Steam Supply Outboard Isolation Valve AND   E4150-F600, HPCI Steam Supply Outboard Isolation Bypass Valve  
 
Correct Answer : D Justification: E4150-F003 and E4150-F600 are powered from MCC 2PB-1.
Plausible Distractors A is plausible, E4150-F002 is powered from MCC 72C-3A.
B is plausible, E4150-F003 is powered from MCC 2PB-1 but is not the only listed valve losing power.
B is plausible, E4150-F003 is powered from MCC 2PB-1 but is not the only listed valve losing power.
C is plausible, E4150-F002 is powered from MCC 72C-3A, E4150-F003 is powered from MCC 2PB-1.
C is plausible, E4150-F002 is powered from MCC 72C-3A, E4150-F003 is powered from MCC 2PB-1.
Objective Link: LP-OP-315-0139-A014 2006 Fermi-2 NRC RO License Exam - Retake RO 41 Tier 2 K/A Number 209001 Statement A1.07 IR 3.0 Origin B Source Question  Fermi-2 2003 NRC Exam LOK H (2RI/ 3PEO) Grp 1 10 CFR 55.41(b) 7 LOD (1-5) 2.3 Reference Documents ST-OP-315-0040-001, Rev 14 QUESTION 43 
Objective Link: LP-OP-315-0139-A014
 
With the plant operating at 100% power, a SIMULTANEOUS Loss of Offsite Power AND  Loss of Coolant Accident occurred.
 
Assuming no other failures, how will the Core Spray system pumps respond?


_____ A. Pumps must be started manually as power is restored to the ESF buses.  
2006 Fermi-2 NRC RO License Exam - Retake RO      Tier          K/A Number          Statement    IR    Origin  Source Question 41        2              209001              A1.07      3.0      B    Fermi-2 2003 NRC Exam LOK      Grp        10 CFR 55.41(b) 7      LOD (1-5)    Reference Documents H (2RI/      1                                    2.3      ST-OP-315-0040-001, Rev 14 3PEO)
 
QUESTION 43 With the plant operating at 100% power, a SIMULTANEOUS Loss of Offsite Power AND Loss of Coolant Accident occurred.
_____ B. All pumps automatically start 5 seco nds after the EDGs energize the ESF buses.  
Assuming no other failures, how will the Core Spray system pumps respond?
 
_____ A.       Pumps must be started manually as power is restored to the ESF buses.
_____ C. All pumps automatically start immediately after the EDGs energize the ESF buses.
_____ B.       All pumps automatically start 5 seconds after the EDGs energize the ESF buses.
_____ D. Division 1 pumps automatically star t 5 seconds after CTG 11-1 energizes the   Division 1 ESF buses.  
_____ C.       All pumps automatically start immediately after the EDGs energize the ESF buses.
 
_____ D.       Division 1 pumps automatically start 5 seconds after CTG 11-1 energizes the Division 1 ESF buses.
Correct Answer : B Pumps start automatically (5secs) after E SF busses energize on Level 1 or High Drywell Pressure.
Correct Answer : B Pumps start automatically (5secs) after ESF busses energize on Level 1 or High Drywell Pressure.
Plausible Distractors:
Plausible Distractors:
A is plausible, if pump starts were disabled due to Bus Lockout condition.
A is plausible, if pump starts were disabled due to Bus Lockout condition.
C is plausible, if candidate doe sn't understand logic and basis. D is plausible, if misconception between Statio n Blackout and Loss of Offsite Power occurs.
C is plausible, if candidate doesnt understand logic and basis.
Objective Link: ST-OP-315-0040-B002  
D is plausible, if misconception between Station Blackout and Loss of Offsite Power occurs.
 
Objective Link: ST-OP-315-0040-B002
2006 Fermi-2 NRC RO License Exam - Retake RO 42 Tier 2 K/A Number 211000 Statement A2.06 IR 3.1 Origin M Source Question  Fermi-2  2003 NRC Exam LOK H (3SPK) Grp 1 10 CFR 55.41(b) 8 LOD (1-5) 3.0 Reference Documents 23.139 Rev 40 QUESTION 44 


The SLC Initiation Keylock Switch, C4100- M004, has been placed in the PMP A RUN position.
2006 Fermi-2 NRC RO License Exam - Retake RO      Tier        K/A Number          Statement      IR    Origin  Source Question 42      2              211000              A2.06        3.1    M    Fermi-2 2003 NRC Exam LOK      Grp      10 CFR 55.41(b) 8        LOD (1-5)    Reference Documents H      1                                    3.0      23.139 Rev 40 (3SPK)
QUESTION 44 The SLC Initiation Keylock Switch, C4100- M004, has been placed in the PMP A RUN position.
The following indications are noted 30 seconds later:
The following indications are noted 30 seconds later:
* Reactor Pressure is 1000 psig.
* Reactor Pressure is 1000 psig.
Line 1,008: Line 743:
* SLC Continuity Lights A and B are ON.
* SLC Continuity Lights A and B are ON.
* SLC Pump A CMC Switch, red light is ON, green light is OFF.
* SLC Pump A CMC Switch, red light is ON, green light is OFF.
* C41-R600, SLC Pump Discharge Pressure Indicator, is oscilla ting between 1370 and 1320 psig.  
* C41-R600, SLC Pump Discharge Pressure Indicator, is oscillating between 1370 and 1320 psig.
 
These are indications of what condition, and what should the operator do?
These are indications of what condi tion, and what should the operator do?  
_____ A.     SLC Explosive Valves failed to fire; start SLC Pump B.
 
_____ B.     Normal operation for the SLC System; monitor SLC Tank level.
_____ A. SLC Explosive Valves failed to fire; start SLC Pump B.
_____ C.     C41-F001, SLC Storage Tank Outlet Valve, is shut; dispatch an operator to open C41-F001.
_____ B. Normal operation for the SLC System; monitor SLC Tank level.
_____ D.     C41-F029A, SLC Pump A Discharge Relief Valve, failed open; dispatch an operator to gag shut C41-F029A.
_____ C. C41-F001, SLC Storage Tank Outlet Valv e, is shut; dispatch an operator to   open C41-F001.
Correct Answer : A If the C41-F004A & B, failed to fire, positive displacement SLC Pump A will OPEN C41-F029A, SLC Pump A Discharge Relief Valve, which causes pressure oscillations between 1370 and 1320 psig. These are the lift and reseat pressures for C41-F029A. Starting SLC Pump B will fire the other primer in both valves.
_____ D. C41-F029A, SLC Pump A Discharge Relief Valve, failed open; dispatch an   operator to gag shut C41-F029A.  
 
Correct Answer : A If the C41-F004A & B, failed to fire, positive displacement SLC Pump A will OPEN C41-F029A, SLC Pump A Discharge Relief Valve, which causes pressure oscillations between 1370 and 1320 psig. These are the lift and rese at pressures for C41-F029A. Starting SLC Pump B will fire the other primer in both valves.
2006 Fermi-2 NRC RO License Exam - Retake Plausible Distractors:  B is plausible, Normal Indication would be Discharge Pressure slightly higher than Reactor Pressure AND lowering SLC Tank Level.
C is plausible, the Tank Level would remain steady if the Storage Tank Outlet were shut, but discharge pressure would be low.  


2006 Fermi-2 NRC RO License Exam - Retake Plausible Distractors:
B is plausible, Normal Indication would be Discharge Pressure slightly higher than Reactor Pressure AND lowering SLC Tank Level.
C is plausible, the Tank Level would remain steady if the Storage Tank Outlet were shut, but discharge pressure would be low.
D is plausible, Relief Valve has opened, but has not failed.
D is plausible, Relief Valve has opened, but has not failed.
Objective Link: LP-OP-315-0114-C010 Source Question:  
Objective Link: LP-OP-315-0114-C010 Source Question:
 
On direction from the CRS, an operator has placed the SLC Initiation Keylock Switch (C4100 M004) in the PMP A Run position.
On direction from the CRS, an operator has placed the SLC Initiation Keylock Switch (C4100 M004) in the PMP A Run position.  
The following indications are noted 30 seconds later:
 
"C41 LIR601 (SLC Tank Level) steady "Primer circuit continuity indicators OFF "SLC pump A red light ON, green light OFF "C41 PI R600 (SLC Pump Discharge Pressure) pulsating at 1400 psig (MODIFICATION)
The following indications are noted 30 seconds later:  
These are indications of what condition, and what should the operator do?
 
"C41 LIR601 (SLC Tank Level) steady "Primer circuit continuity indicators OFF "SLC pump A red light ON, green light OFF "C41 PI R600 (SLC Pump Disc harge Pressure) pulsating at 1400 psig (MODIFICATION)
 
These are indications of what condi tion, and what should the operator do?  
 
A Normal operation for the SLC System; monitor SLC Tank level.
A Normal operation for the SLC System; monitor SLC Tank level.
B C41-F004A, Pump A Squib Valve, failed to fire; start SLC pump B.
B C41-F004A, Pump A Squib Valve, failed to fire; start SLC pump B.
C C41-F001, SLC Storage Tank Outlet Valve, is open; dispatch operator to close C41-F001. (MODIFICATION) D C41-F029A, SLC Pump A Discharge Relief Va lve, failed open; dispatch operator to gag open C41-F029A. (MODIFICATION)
C C41-F001, SLC Storage Tank Outlet Valve, is open; dispatch operator to close C41-F001.
 
(MODIFICATION)
2006 Fermi-2 NRC RO License Exam - Retake RO 43 Tier 2 K/A Number 212000 Statement A3.05 IR 3.9 Origin B Source Question Clinton 2001 NRC Exam LOK H (2DR/ 3PEO) Grp 1 10 CFR 55.41(b) 7 LOD (1-5) 2.5 Reference Documents 3D94, Rev 7;  3D113, Rev 20;  3D6, Rev 9  QUESTION 45
D C41-F029A, SLC Pump A Discharge Relief Valve, failed open; dispatch operator to gag open C41-F029A. (MODIFICATION)
 
A plant startup is in progress. Reactor Pressure is stable at 100 psig, when the following alarms are received.
* 3D2,  SCRAM DISCH VOLUME HIGH
* 3D73,  TRIP ACTUATORS A1 / A2 TRIPPED
* 3D74,  TRIP ACTUATORS B1 / B2 TRIPPED
* 3D94,  DISCH WATER VOL HI GH LEVEL CHANNEL TRIP
 
Based on these conditions, which one of the foll owing describes the status of the following annunciators?
 
(1) 3D113, CONTROL ROD WITHDRAWAL BLOCKED (2) 3D6, SCRAM VALVE PILOT AIR HDR PRESS HIGH / LOW 
 
(1)  (2)
_____ A.          Clear            Clear
 
_____ B.          Clear          Alarming
 
_____ C.        Alarming            Clear
 
_____ D.        Alarming          Alarming
 
Correct Answer :  D Scram Discharge Volume High Level Trip causes BOTH Rod Block and Scram.
Plausible Distractors: A is plausible, if SDV Level RPS Trip and Rod Block functions are not known.
B is plausible if Rod Block function is not known.


2006 Fermi-2 NRC RO License Exam - Retake RO      Tier          K/A Number          Statement      IR    Origin  Source Question 43        2              212000              A3.05        3.9      B    Clinton 2001 NRC Exam LOK      Grp        10 CFR 55.41(b) 7      LOD (1-5)      Reference Documents H        1                                    2.5      3D94, Rev 7; 3D113, Rev 20; 3D6, (2DR/                                                      Rev 9 3PEO)
QUESTION 45 A plant startup is in progress. Reactor Pressure is stable at 100 psig, when the following alarms are received.
* 3D2, SCRAM DISCH VOLUME HIGH
* 3D73, TRIP ACTUATORS A1 / A2 TRIPPED
* 3D74, TRIP ACTUATORS B1 / B2 TRIPPED
* 3D94, DISCH WATER VOL HIGH LEVEL CHANNEL TRIP Based on these conditions, which one of the following describes the status of the following annunciators?
(1) 3D113, CONTROL ROD WITHDRAWAL BLOCKED (2) 3D6, SCRAM VALVE PILOT AIR HDR PRESS HIGH / LOW (1)                  (2)
_____ A.              Clear                Clear
_____ B.              Clear                Alarming
_____ C.            Alarming                Clear
_____ D.            Alarming              Alarming Correct Answer : D Scram Discharge Volume High Level Trip causes BOTH Rod Block and Scram.
Plausible Distractors:
A is plausible, if SDV Level RPS Trip and Rod Block functions are not known.
B is plausible if Rod Block function is not known.
C is plausible if RPS Trip function is not known.
C is plausible if RPS Trip function is not known.
2006 Fermi-2 NRC RO License Exam - Retake Objective Link:  ST-OP-315-0027-001-A013 2006 Fermi-2 NRC RO License Exam - Retake RO 44 Tier 2 K/A Number 215003 Statement A4.05 IR 3.4 Origin M Source Question Fitzpatrick 2003 NRC Exam LOK F (1I) Grp 1 10 CFR 55.41(b) 7 LOD (1-5) 2.4 Reference Documents 3D59, Rev 5 QUESTION 46 
Intermediate Range Monitor (IRM) Up scale RPS Trips are BYPASSED when _____________.
_____ A. the IRM is on Range 8


_____ B.
2006 Fermi-2 NRC RO License Exam - Retake Objective Link: ST-OP-315-0027-001-A013
ALL APRMs are downscale
_____ C.
ALL SRMs are fully inserted
_____ D. the Reactor Mode Switch is in RUN


Correct Answer : D IRM Trips are bypassed with the Reactor Mode Switch in RUN.
2006 Fermi-2 NRC RO License Exam - Retake RO      Tier          K/A Number          Statement  IR    Origin  Source Question 44        2            215003              A4.05    3.4      M      Fitzpatrick 2003 NRC Exam LOK      Grp      10 CFR 55.41(b) 7      LOD (1-5)  Reference Documents F (1I)      1                                  2.4    3D59, Rev 5 QUESTION 46 Intermediate Range Monitor (IRM) Upscale RPS Trips are BYPASSED when _____________.
_____ A.      the IRM is on Range 8
_____ B.      ALL APRMs are downscale
_____ C.      ALL SRMs are fully inserted
_____ D.      the Reactor Mode Switch is in RUN Correct Answer : D IRM Trips are bypassed with the Reactor Mode Switch in RUN.
Plausible Distractors:
Plausible Distractors:
A is plausible, SRM Upscale Trips are BYPASSED when IRMs are on Range 8.
A is plausible, SRM Upscale Trips are BYPASSED when IRMs are on Range 8.
B is plausible, potential misc onception with Companion Trips. C is plausible. potential misconception with SRM Detector Retract Not Permitted.
B is plausible, potential misconception with Companion Trips.
Objective Link: ST-OP-315-0023-A016 Source Question:
C is plausible. potential misconception with SRM Detector Retract Not Permitted.
An IRM HI Flux Control Rod Block is automatically bypassed when___________? (MODIFICATION)
Objective Link: ST-OP-315-0023-A016 Source Question:
 
An IRM HI Flux Control Rod Block is automatically bypassed when___________?
A The IRM is on Range
(MODIFICATION)
: 1. (MODIFICATION)
A The IRM is on Range 1. (MODIFICATION)
B The SRM's are fully inserted.
B The SRM's are fully inserted.
C The IRM's companion APRM is downscale. (MODIFICATION)
C The IRM's companion APRM is downscale. (MODIFICATION)
D The Reactor Mode Switch is placed in RUN.  
D The Reactor Mode Switch is placed in RUN.
 
2006 Fermi-2 NRC RO License Exam - Retake RO 46 Tier 2 K/A Number 215005 Statement K1.16 IR 3.3 Origin N Source Question N/A LOK H (3PEO) Grp 1 10 CFR 55.41(b) 6 LOD (1-5) 3.5 Reference Documents:
3D119, Rev 10; 3D115, Rev 9 QUESTION 47 


With Reactor Power at 100%, the following alarms and indications occur:
2006 Fermi-2 NRC RO License Exam - Retake RO      Tier          K/A Number            Statement      IR    Origin  Source Question 46        2              215005              K1.16        3.3    N    N/A LOK      Grp      10 CFR 55.41(b) 6        LOD (1-5)    Reference Documents:
* 3D113, CONTROL ROD WI THDRAWAL BLOCK
H        1                                    3.5      3D119, Rev 10; 3D115, Rev 9 (3PEO)
QUESTION 47 With Reactor Power at 100%, the following alarms and indications occur:
* 3D113, CONTROL ROD WITHDRAWAL BLOCK
* 3D115, APRM FLOW UPSCALE
* 3D115, APRM FLOW UPSCALE
* B31-R617, Recirc A Loop Flow Indicator, is UNCHANGED at 42 KGPM.
* B31-R617, Recirc A Loop Flow Indicator, is UNCHANGED at 42 KGPM.
* B31-R613, Recirc B Loop Flow Indicator, is UNCHANGED at 42 KGPM.
* B31-R613, Recirc B Loop Flow Indicator, is UNCHANGED at 42 KGPM.
* Reactor Power is UNCHANGED at 100%.
* Reactor Power is UNCHANGED at 100%.
* B31-R614, Recirc Loops Flow Recorder, indicates UPSCALE on Loops "A" and "B".
* B31-R614, Recirc Loops Flow Recorder, indicates UPSCALE on Loops A and B.
What is the effect of this failure and what is the proper crew response?
What is the effect of this failure and what is the proper crew response?
 
_____ A.       This will cause OPRM protection to be enabled. Bypass RBM A.
_____ A. This will cause OPRM protection to be enabled. Bypass RBM A.
_____ B.       This will cause OPRM protection to be enabled. Bypass APRM Channel 1.
 
_____ C.       This will prevent OPRM protection from becoming enabled. Bypass RBM A.
_____ B. This will cause OPRM protection to be enabled. Bypass APRM Channel 1.  
_____ D.       This will prevent OPRM protection from becoming enabled. Bypass APRM Channel 1.
 
Correct Answer : D APRM Channel 1 provides Recirc Loop A and Loop B flow signals to B31-R614, Recirc Loops A and B Flow Recorder. OPRMs are enabled ONLY below 60% Recirc Flow and Simulated Thermal Power greater than 28%. OPRM protection for APRM 1 is prevented and cannot be enabled.
_____ C. This will prevent OPRM protection from becoming enabled. Bypass RBM A.  
 
_____ D. This will prevent OPRM protection from becoming enabled. Bypass APRM Channel 1.  
 
Correct Answer : D APRM Channel 1 provides Recirc Loop A and Loop B flow signals to B31-R614, Recirc Loops A and B Flow Recorder. OPRMs are enabled ONLY below 60% Recirc Flow and Simulated Thermal Power greater than 28%. OP RM protection for APRM 1 is prevented and cannot be enabled.
Plausible Distractors:
Plausible Distractors:
A/C are plausible, RBM processe s flow unit input to IPCS only.
A/C are plausible, RBM processes flow unit input to IPCS only.
B is plausible, however low flow is required to enable OPRM protection.
B is plausible, however low flow is required to enable OPRM protection.
2006 Fermi-2 NRC RO License Exam - Retake Objective Link:  ST-OP-315-0024-A015


2006 Fermi-2 NRC RO License Exam - Retake RO 47 Tier 2 K/A Number 217000 Statement K2.01 IR 2.8 Origin N Source Question N/A LOK F (1F) Grp 1 10 CFR 55.41(b) 7 LOD (1-5) 2.4 Reference Documents 23.206, Rev 83 QUESTION 48
2006 Fermi-2 NRC RO License Exam - Retake Objective Link: ST-OP-315-0024-A015


When 480 VAC MCC 72F becomes DEENERGIZED, which one of the following RCIC valves will lose power?  
2006 Fermi-2 NRC RO License Exam - Retake RO      Tier          K/A Number        Statement      IR      Origin  Source Question 47        2            217000              K2.01      2.8      N      N/A LOK        Grp      10 CFR 55.41(b) 7    LOD (1-5)    Reference Documents F (1F)      1                                  2.4      23.206, Rev 83 QUESTION 48 When 480 VAC MCC 72F becomes DEENERGIZED, which one of the following RCIC valves will lose power?
 
_____ A.       E5150-F095, RCIC Turbine Steam Inlet Bypass Valve
_____ A. E5150-F095 , RCIC Turbine Steam Inlet Bypass Valve
_____ B.       E5150-F007, RCIC Steam Line Inboard Isolation Valve
_____ B. E5150-F007, RCIC Steam Line Inboard Isolation Valve  
_____ C.       E5150-F008, RCIC Steam Line Outboard Isolation Valve
 
_____ D.       E5150-F084, RCIC Exhaust Vacuum Breaker Inboard Isolation Valve Correct Answer : B E5150-F007, RCIC Steam Line Inboard Isolation Valve is powered from 480 VAC MCC 72F-4A Pos 4D.
_____ C. E5150-F008 , RCIC Steam Line Outboard Isolation Valve  
 
_____ D. E5150-F084, RCIC Exhaust Vacuum Breaker Inboard Isolation Valve  
 
Correct Answer : B E5150-F007, RCIC Steam Line Inboard Isolation Valve is powered from 480 VAC MCC 72F-4A Pos 4D.
Plausible Distractors:
Plausible Distractors:
A is plausible, but is powered from D1 DC MCC 2PA-1 pos 7C. C is plausible, but is powered from D1 DC MCC 2PA-1 Pos 3A.
A is plausible, but is powered from D1 DC MCC 2PA-1 pos 7C.
C is plausible, but is powered from D1 DC MCC 2PA-1 Pos 3A.
D is plausible, but is powered from D2 DC MCC 2PB-1 Pos 6C. It is also an inboard primary containment isolation valve, which in most cases is located in the primary containment and AC powered. This valve is located outside of the primary containment. (Torus Room)
D is plausible, but is powered from D2 DC MCC 2PB-1 Pos 6C. It is also an inboard primary containment isolation valve, which in most cases is located in the primary containment and AC powered. This valve is located outside of the primary containment. (Torus Room)
Objective Link: ST-OP-315-0043-A014  
Objective Link: ST-OP-315-0043-A014


2006 Fermi-2 NRC RO License Exam - Retake RO 48 Tier 2 K/A Number 218000 Statement K3.01 IR 4.4 Origin M Source Question Dresden 2002 NRC Exam LOK H (3PEO) Grp 1 10 CFR 55.41(b)7 LOD (1-5) 3.3 Reference Documents 1D44 Rev 12, 1D31 Rev 10 QUESTION 49  
2006 Fermi-2 NRC RO License Exam - Retake RO       Tier         K/A Number           Statement    IR    Origin  Source Question 48        2            218000               K3.01       4.4     M     Dresden 2002 NRC Exam LOK       Grp       10 CFR 55.41(b)7       LOD (1-5)   Reference Documents H        1                                  3.3       1D44 Rev 12, 1D31 Rev 10 (3PEO)
 
QUESTION 49 A transient occurs, resulting in the following conditions:
A transient occurs, resulting in the following conditions:
* ALL MSIVs are closed.
* ALL MSIVs are closed.
* HPCI is operating and injecting into the vessel.
* HPCI is operating and injecting into the vessel.
Line 1,139: Line 841:
* Drywell pressure is 1.0 psig and trending up at 0.05 psig/min.
* Drywell pressure is 1.0 psig and trending up at 0.05 psig/min.
* 1D57, ADS/SRV/EECW TCV POWER SUPPLY FAILURE, alarms.
* 1D57, ADS/SRV/EECW TCV POWER SUPPLY FAILURE, alarms.
* 2PA2-5 Circuit 1 is de-energized and cannot be restored.  
* 2PA2-5 Circuit 1 is de-energized and cannot be restored.
 
3 minutes later, the following H11-P601 panel annunciators alarm:
3 minutes later, the following H11-P601 panel annunciators alarm:
* 1D31, ADS DRYWELL PRESS BYPASS TIMER INITIATE A / B LOGIC
* 1D31, ADS DRYWELL PRESS BYPASS TIMER INITIATE A / B LOGIC
* 1D36, ADS ECCS PUMP CH B PERMISSIVE From the receipt of the alarms, the EARLIEST that ADS Valves should be AUTOMATICALLY OPENED, is:
* 1D36, ADS ECCS PUMP CH B PERMISSIVE From the receipt of the alarms, the EARLIEST that ADS Valves should be AUTOMATICALLY OPENED, is:
_____ A.      2 minutes
_____ B.      7 minutes
_____ C.      9 minutes
_____ D.      Never (valves remain closed)
Correct Answer : C Annunciators indicate that L1 (31.8 inches) has occurred.
L1 + 7 minutes (DW Bypass Timer) = 7 minutes + 105 seconds = 8 minutes and 45 seconds ADS Valves OPEN. Loss of 2PA2-5 disables ADS Logic A, but ADS Logic B is powered and


_____ A. 2 minutes
2006 Fermi-2 NRC RO License Exam - Retake has dual power supplies (2PA2-5 & 2PA2-6). ADS Logic B is sufficient to initiate ADS.
 
Plausible Distractors:
_____ B. 7 minutes
A is plausible, 105 seconds from L1, IF Hi DW Pressure existed, this would be correct.
 
B is plausible, 7 minutes from L1, candidate may select if misconception exists about logic and 105 sec timer.
_____ C. 9 minutes
_____ D. Never (valves remain closed)
 
Correct Answer :  C Annunciators indicate that L1 (31.8 inches) has occurred. L1 + 7 minutes (DW Bypass Timer)  =  7 minutes + 105 seconds = 8 minutes and 45 seconds ADS Valves OPEN. Loss of 2P A2-5 disables ADS Logic A, but ADS Logic B is powered and 2006 Fermi-2 NRC RO License Exam - Retake has dual power supplies (2PA2-5 & 2PA2-6). ADS Logic B is sufficient to initiate ADS.
Plausible Distractors: A is plausible, 105 seconds from L1, IF Hi DW Pressure existed, this would be correct. B is plausible, 7 minutes from L1, candidate may select if misconception exists about logic and 105 sec timer.
D is plausible, if candidate believes loss of 2PA2-5 will disable both logic trains/systems.
D is plausible, if candidate believes loss of 2PA2-5 will disable both logic trains/systems.
Objective Link: ST-OP-315-0042-B003 Source Question:  
Objective Link: ST-OP-315-0042-B003 Source Question:
 
At 10:44, the following conditions exist on Unit 2:
At 10:44, the following condi tions exist on Unit 2: A Steam Line Break occurred in the Drywell (MODIFICATION)
A Steam Line Break occurred in the Drywell (MODIFICATION)
The MSIVs are closed HPCI is operating and injecting to the vessel RPV Water Level is -45 inches and trending down at two inches per minute (MODIFICATION) Reactor pressure is 900 psig and steady Drywell pressure is 1.5 psig, rising at 0.2 psig per minute (MODIFICATION)
The MSIVs are closed HPCI is operating and injecting to the vessel RPV Water Level is -45 inches and trending down at two inches per minute (MODIFICATION)
At 10:47, the following 902-3 panel annunciators alarm: ADS PERMISSIVE DW PRESSURE HIGH (E-15) (MODIFICATION)
Reactor pressure is 900 psig and steady Drywell pressure is 1.5 psig, rising at 0.2 psig per minute (MODIFICATION)
At 10:47, the following 902-3 panel annunciators alarm:
ADS PERMISSIVE DW PRESSURE HIGH (E-15) (MODIFICATION)
ADS TIMER START (B-13)
ADS TIMER START (B-13)
LPCI/CS PP AT PRESS (H-13)
LPCI/CS PP AT PRESS (H-13)
ADS INHIBIT (G-11) (MODIFICATION)
ADS INHIBIT (G-11) (MODIFICATION)
What is the state of this reactor at 10:54? (MODIFICATION)
What is the state of this reactor at 10:54? (MODIFICATION)
A Reactor Water Level is still trending down (MODIFICATION)
A Reactor Water Level is still trending down (MODIFICATION)
B HPCI is maintaining level in the vessel (MODIFICATION)
B HPCI is maintaining level in the vessel (MODIFICATION)
C All five ADS relief valves are open (MODIFICATION)
C All five ADS relief valves are open (MODIFICATION)
D LPCI and Core Spray pumps are r unning and injecting water into the vessel(MODIFICATION)
D LPCI and Core Spray pumps are running and injecting water into the vessel(MODIFICATION)
 
2006 Fermi-2 NRC RO License Exam - Retake RO 49 Tier 2 K/A Number 223002 Statement K4.06 IR 3.4 Origin B Source Question  Fermi-2 2003 NRC Exam LOK F (1I) Grp 1 10 CFR 55.41(b) 7 LOD (1-5) 3.2 Reference Documents 23.427, Rev 18; ST-OP-315-0048-001, Rev 11  QUESTION 50
 
The plant is in Mode 4 with RHR Loop "A
" operating in the Shutdown Cooling Mode.
A RHR Shutdown Cooling Isolation has occurred. 
 
Which one of the following lists the MINIMUM condition(s) and/or action(s) which will allow Shutdown Cooling Suction Valves to be reopened?
 
_____ A.
ONLY the initiating condition must be corrected and restored to normal.
 
_____ B.
ONLY Main Steam Line Isolation RESET pushbuttons on H11-P601 and  H11-P602 must be depressed.
_____ C. The initiating condition must be corrected and restored to normal AND  Main Steam Line Isolation RE SET pushbuttons on H11-P601 and  H11-P602 must be depressed.
_____ D. The initiating condition must be corrected and restored to normal AND  the close push button on the affected isolation valves must be depressed AND  ONLY the Main Steam Line Isolation RE SET pushbutton on H11-P601 must be    depressed.
 
Correct Answer :  C  RHR SDC Valves may be reopned after the initiati ng condition has been co rrected and restored to normal AND Main Steam Line Isolation RESET pushbuttons on H11-P601 and H11-P602 have been depressed.
Plausible Distractors: 


2006 Fermi-2 NRC RO License Exam - Retake RO      Tier          K/A Number            Statement      IR    Origin  Source Question 49        2              223002              K4.06        3.4    B      Fermi-2 2003 NRC Exam LOK      Grp        10 CFR 55.41(b) 7      LOD (1-5)      Reference Documents F (1I)      1                                    3.2        23.427, Rev 18; ST-OP-315-0048-001, Rev 11 QUESTION 50 The plant is in Mode 4 with RHR Loop A operating in the Shutdown Cooling Mode.
A RHR Shutdown Cooling Isolation has occurred.
Which one of the following lists the MINIMUM condition(s) and/or action(s) which will allow Shutdown Cooling Suction Valves to be reopened?
_____ A.      ONLY the initiating condition must be corrected and restored to normal.
_____ B.      ONLY Main Steam Line Isolation RESET pushbuttons on H11-P601 and H11-P602 must be depressed.
_____ C.      The initiating condition must be corrected and restored to normal AND Main Steam Line Isolation RESET pushbuttons on H11-P601 and H11-P602 must be depressed.
_____ D.      The initiating condition must be corrected and restored to normal AND the close push button on the affected isolation valves must be depressed AND ONLY the Main Steam Line Isolation RESET pushbutton on H11-P601 must be depressed.
Correct Answer : C RHR SDC Valves may be reopned after the initiating condition has been corrected and restored to normal AND Main Steam Line Isolation RESET pushbuttons on H11-P601 and H11-P602 have been depressed.
Plausible Distractors:
A is plausible, but is inadequate to permit reopening SDC Valves.
A is plausible, but is inadequate to permit reopening SDC Valves.
B is plausible, but is inadequate to permit reopening SDC Valves.
B is plausible, but is inadequate to permit reopening SDC Valves.
D is plausible, but is not th e MINIMUM conditions / actions.
D is plausible, but is not the MINIMUM conditions / actions.
2006 Fermi-2 NRC RO License Exam - Retake Objective Link: ST-OP-0048-A015 2006 Fermi-2 NRC RO License Exam - Retake RO 59 Tier 2 K/A Number 211000 Statement K6.03 IR 3.2 Origin N Source Question N/A LOK H (2RI) Grp 1 10 CFR 55.41(b) 7 LOD (1-5) 3.5 Reference Documents 23.106 Rev 85, 23.139 Rev 41 QUESTION 51
 
2006 Fermi-2 NRC RO License Exam - Retake Objective Link: ST-OP-0048-A015


Following a LOSS OF OFFSITE POWER, the following conditions exist:
2006 Fermi-2 NRC RO License Exam - Retake RO      Tier        K/A Number          Statement    IR    Origin  Source Question 59        2          211000              K6.03      3.2      N    N/A LOK      Grp    10 CFR 55.41(b) 7        LOD (1-5)  Reference Documents H (2RI)      1                                3.5      23.106 Rev 85, 23.139 Rev 41 QUESTION 51 Following a LOSS OF OFFSITE POWER, the following conditions exist:
* Reactor Power is 20%.
* Reactor Power is 20%.
* EDG 13 FAILED to start.
* EDG 13 FAILED to start.
* Power to ESF Bus 72B has been LOST.
* Power to ESF Bus 72B has been LOST.
Which one of the following pumps IS AVAILABLE for reactivity control?  
Which one of the following pumps IS AVAILABLE for reactivity control?
_____ A.      C4103-C001A, SLC PUMP A
_____ B.      C4103-C001B, SLC PUMP B
_____ C.      C1106-C001A, EAST CRD PUMP
_____ D.      C1106-C001B, WEST CRD PUMP Correct Answer : C Bus 64B is the power supply to CRD Pump A Plausible Distractors:
A is plausible, SLC Pump A is an ATWS reactivity control system pump, but is fed from Bus 72B. This bus lost power (given in stem). Candidate must know power supply.
B is plausible, SLC Pump B is an ATWS reactivity control system pump, but is fed from Bus 72E. EDG 13 failed to start (given in stem) which would supply its power supply (72E).
D is plausible, W. CRD Pump is an ATWS reactivity control system pump, but is fed from Bus 65E. EDG 13 failed to start (given in stem) which would supply its power supply (65E).
Objective Link: ST-OP-315-0010-A014


_____ A. C4103-C001A, SLC PUMP A  
2006 Fermi-2 NRC RO License Exam - Retake RO      Tier          K/A Number            Statement      IR    Origin  Source Question 50        2              239002                K5.06      2.7      B      Grand Gulf 2002 NRC Exam LOK      Grp        10 CFR 55.41(b)3        LOD (1-5)      Reference Documents:
 
F (1B)      1                                    2.6        ST-OP-315-0005-001 Rev 15 QUESTION 52 Which one of the following describes the function of the Safety Relief Valve Tailpipe Vacuum Breakers?
_____ B. C4103-C001B, SLC PUMP B
_____ A.      Relieve steam from the SRV tailpipes following SRV actuation to the Drywell to prevent excessive back pressure on the SRV discs.
 
_____ B.       Relieve differential pressures built up in the SRV tailpipes following actuation that would result in lift pressures for SRVs which are in excess of design.
_____ C. C1106-C001A, EAST CRD PUMP
_____ C.      Equalize pressure established in the SRV tailpipes to assure positive actuation of the SRV Tailpipe Pressure Switches for accurate SRV position indication.
 
_____ D.      Equalize pressure conditions in the SRV tailpipes to prevent Torus water from being drawn into the piping which could result in excessive hydraulic loads.
_____ D. C1106-C001B, WEST CRD PUMP
Correct Answer : D SRV Tailpipe Vacuum Breakers prevent condensing steam in the Tailpipe from drawing Torus Water upward into the Tailpipe, which would result in water slug flow on subsequent lifts, which may produce excessive hydraulic loads.
Plausible Distractors:
A is a plausible, but incorrect function.
B is a plausible, but incorrect function.
C is a plausible, but incorrect function.
Objective Link: ST-OP-315-0005-A008


Correct Answer :  C Bus 64B is the power supply to CRD Pump A Plausible Distractors:
2006 Fermi-2 NRC RO License Exam - Retake RO     Tier         K/A Number             Statement     IR     Origin Source Question 26       1             295031               EA2.04     4.6     N   N/A LOK     Grp       10 CFR 55.41(b) 10         LOD (1-5)   Reference Documents H        1                                      2.8     29.100.01, RPV Control, Sheet 1 (2DR)
A is plausible, SLC Pump A is an ATWS reactivity control system pump, but is fed from Bus 72B. This bus lost power (given in stem). Candidate must know power supply.
QUESTION 53 Following a transient, plant conditions are:
 
B is plausible, SLC Pump B is an ATWS reactivity control system pump, but is fed from Bus 72E. EDG 13 failed to start (given in stem) which would supply its power supply (72E). D is plausible, W. CRD Pump is an ATWS reactivity control system pump, but is fed from Bus 65E. EDG 13 failed to start (given in stem) which would supply its power supply (65E).
Objective Link:  ST-OP-315-0010-A014 2006 Fermi-2 NRC RO License Exam - Retake RO 50 Tier 2 K/A Number 239002 Statement K5.06 IR 2.7 Origin B Source Question Grand Gulf 2002 NRC Exam LOK F (1B) Grp 1 10 CFR 55.41(b)3 LOD (1-5) 2.6 Reference Documents:
ST-OP-315-0005-001 Rev 15 QUESTION 52 
 
Which one of the following describes the function of the Safety Relief Valve Tailpipe Vacuum Breakers?
 
_____ A. Relieve steam from the SRV tailpipes following SRV actuation to the Drywell to  prevent excessive back pressure on the SRV discs. 
 
_____ B. Relieve differential pressures built up in the SRV tailpipes following actuation that  would result in lift pressures for SRVs which are in excess of design.
_____ C. Equalize pressure established in the SRV tailpipes to assure positive actuation of  the SRV Tailpipe Pressure Switches for accurate SRV position indication.
_____ D. Equalize pressure conditions in the SRV tailpipes to prevent Torus water from  being drawn into the piping which could result in excessive hydraulic loads. 
 
Correct Answer : D  SRV Tailpipe Vacuum Breakers prevent condensing steam in the Tailpipe from drawing Torus Water upward into the Tailpipe, which would re sult in water slug flow on subsequent lifts, which may produce excessive hydraulic loads.
Plausible Distractors:
 
A is a plausible, but incorrect function.
 
B is a plausible, but incorrect function.
 
C is a plausible, but incorre ct function.
Objective Link:  ST-OP-315-0005-A008
 
2006 Fermi-2 NRC RO License Exam - Retake RO 26 Tier 1 K/A Number 295031 Statement EA2.04 IR 4.6 Origin N Source Question N/A LOK H (2DR) Grp 1 10 CFR 55.41(b) 10 LOD (1-5) 2.8 Reference Documents 29.100.01, RPV Control, Sheet 1 QUESTION 53  
 
Following a transient, plant conditions are:
* Drywell Pressure is 8 psig.
* Drywell Pressure is 8 psig.
* NO ECCS Pumps are running.
* NO ECCS Pumps are running.
* NO High OR Low Pressure Injection systems are running.
* NO High OR Low Pressure Injection systems are running.
Which of the following is the LOWEST stable RPV Water Level which assures Adequate Core Cooling?  
Which of the following is the LOWEST stable RPV Water Level which assures Adequate Core Cooling?
 
_____ A.       TOP of Active Fuel
_____ A.
_____ B.       25 inches BELOW the Top of Active Fuel
TOP of Active Fuel  
_____ C.       40 inches BELOW the Top of Active Fuel
 
_____ D.       48 inches BELOW the Top of Active Fuel Correct Answer : C Minimum Zero Injection Water Level is by EOP Flowcharts -40 inches.
_____ B. 25 inches BELOW the Top of Active Fuel
_____ C. 40 inches BELOW the Top of Active Fuel
_____ D. 48 inches BELOW the Top of Active Fuel  
 
Correct Answer : C Minimum Zero Injection Water Level is by EOP Flowcharts -40 inches.
Plausible Distractors:
Plausible Distractors:
A is plausible, TAF assures Adequate Core Cooling, but is NOT the LOWEST. B is plausible, and is the lower limit, if Injection Systems are operating.
A is plausible, TAF assures Adequate Core Cooling, but is NOT the LOWEST.
B is plausible, and is the lower limit, if Injection Systems are operating.
D is plausible, if BOTH Core Spray Pumps in one loop are operating.
D is plausible, if BOTH Core Spray Pumps in one loop are operating.
Objective Link: ST-OP-802-3001-001-01-08  
Objective Link: ST-OP-802-3001-001-01-08
 
2006 Fermi-2 NRC RO License Exam - Retake RO 51 Tier 2 K/A Number 259002  Statement K6.05 IR 3.5 Origin N Source Question N/A LOK H (2RI/ 3PEO) Grp 1 10 CFR 55.41(b)7 LOD (1-5) 3.1 Reference Documents 23.107, Rev 106
 
ST-OP-315-0046-001 Rev 13 QUESTION 54 


With the plant operating at 100% power, the following conditions are present:
2006 Fermi-2 NRC RO License Exam - Retake RO      Tier          K/A Number            Statement    IR    Origin    Source Question 51        2              259002              K6.05      3.5      N    N/A LOK      Grp        10 CFR 55.41(b)7        LOD (1-5)    Reference Documents H (2RI/      1                                    3.1      23.107, Rev 106 3PEO)                                                      ST-OP-315-0046-001 Rev 13 QUESTION 54 With the plant operating at 100% power, the following conditions are present:
* 3 ELEMENT Feedwater Control is in effect.
* 3 ELEMENT Feedwater Control is in effect.
* REACTOR LEVEL SELECT Switch is in the "A LEVEL" position.
* REACTOR LEVEL SELECT Switch is in the A LEVEL position.
* C32-R618, Master Feedwater Level C ontroller, is set at 197 inches.
* C32-R618, Master Feedwater Level Controller, is set at 197 inches.
* C32-R606A, Reactor Level "A" Indicator, reads 197 inches.
* C32-R606A, Reactor Level A Indicator, reads 197 inches.
* C32-R606B, Reactor Level "B" Indicator, reads 196 inches.
* C32-R606B, Reactor Level B Indicator, reads 196 inches.
* C32-R606C, Reactor Level "C" Indicator, reads 198 inches.
* C32-R606C, Reactor Level C Indicator, reads 198 inches.
* C32-R606D, Reactor Level "D" Indicator, reads 197 inches.  
* C32-R606D, Reactor Level D Indicator, reads 197 inches.
 
IF C32-R606A, Reactor Level A Indicator, INSTANTANEOUSLY FAILS to 160 inches, how will the plant respond?
IF C32-R606A, Reactor Level "A" Indicator, INSTANTANEOUSLY FAILS to 160 inches, how will the plant respond?  
_____ A.         ACTUAL Reactor Water Level will RISE until an indirect Reactor Scram occurs.
 
_____ B.         ACTUAL Reactor Water Level will LOWER one inch, control has automatically shifted to Reactor Level Channel B.
_____ A. ACTUAL Reactor Water Level will RISE until an indirect Reactor Scram   occurs.
_____ C.       ACTUAL Reactor Water Level will RISE one inch, control has automatically shifted to Reactor Level Channel C.
_____ B. ACTUAL Reactor Water Level will LOWER one inch, control has automatically   shifted to Reactor Level Channel "B".
_____ D.       ACTUAL Reactor Water Level will NOT CHANGE, control has automatically shifted to the Median of the three remaining channels.
_____ C. ACTUAL Reactor Water Level will RISE one inch, control has automatically   shifted to Reactor Level Channel "C".  
Correct Answer : D If the lead selected RPV water level signal, A or B fails, DCS logic will automatically transfer RPV water level control and the input to C32-R618, Master Feedwater Level Controller, to the Median signal of the three remaining RPV water level signals. This will cause ACTUAL Level to NOT CHANGE because the median signal was the same as the pre-failure value of Level Channel A.
 
_____ D. ACTUAL Reactor Water Level will NOT CHANGE, control has automatically   shifted to the Median of the three remaining channels.


Correct Answer : D If the lead selected RPV water level signal, A or B fails, DCS logic will automatically transfer RPV water level control and the input to C32-R6 18, Master Feedwater Leve l Controller, to the Median signal of the three remaining RPV water level signals. This will cause ACTUAL Level to NOT CHANGE because the median signal was the same as the pre-failure value of Level Channel A.
2006 Fermi-2 NRC RO License Exam - Retake Plausible Distractors:
2006 Fermi-2 NRC RO License Exam - Retake Plausible Distractors:
A is plausible, if the candi date does not know Level Control automatically transfers.
A is plausible, if the candidate does not know Level Control automatically transfers.
B is plausible, if the candida te does not know that the Level Control Channel automatically transfers to the median signal. Level B is also the other selectable Lead Channel.
B is plausible, if the candidate does not know that the Level Control Channel automatically transfers to the median signal. Level B is also the other selectable Lead Channel.
C is plausible, if the candidate does not know that the Level Control automatically transfers to the median signal. Channel C is an available level channel.
C is plausible, if the candidate does not know that the Level Control automatically transfers to the median signal. Channel C is an available level channel.
Objective Link: ST-OP-315-0046-B001  
Objective Link: ST-OP-315-0046-B001


2006 Fermi-2 NRC RO License Exam - Retake RO 52  Tier 2 K/A Number 261000 Statement A1.04 IR 3.0 Origin B Source Question N/A LOK H (2RI) Grp 1 10 CFR 55.41(b) 10 LOD (1-5) 3.2 Reference Documents 29.100.01 Sheet 5, Rev 7  
2006 Fermi-2 NRC RO License Exam - Retake RO     Tier         K/A Number           Statement    IR    Origin  Source Question 52        2              261000             A1.04       3.0     B     N/A LOK       Grp       10 CFR 55.41(b) 10       LOD (1-5)   Reference Documents H (2RI)      1                                    3.2       29.100.01 Sheet 5, Rev 7 EPG Bases page B-8-1 QUESTION 55 Drywell Pressure is 2 psig. Div 1 SGTS is in service with Div 2 SGTS OUT OF SERVICE for maintenance. The following indications occur:
 
EPG Bases page B-8-1  
 
QUESTION 55  
 
Drywell Pressure is 2 psig. Div 1 SG TS is in service with Div 2 SGTS OUT OF SERVICE for maintenance. The following indications occur:
* 8D35, DIV I SGTS AIR FLOW STOPPED, alarms
* 8D35, DIV I SGTS AIR FLOW STOPPED, alarms
* T4600-F004A, Div 1 SGTS Exhaust Fan Inlet Isolation Damper, is CLOSED This will result in a condition which FIRST requires entry into the:  
* T4600-F004A, Div 1 SGTS Exhaust Fan Inlet Isolation Damper, is CLOSED This will result in a condition which FIRST requires entry into the:
_____ A.        Radiation Release Control EOP Leg to ensure that any airborne radioactive material, in the Secondary Containment, is not released to the surrounding atmosphere.
_____ B.        Secondary Containment Control EOP Leg to ensure that unfiltered airborne radioactive material, in the Secondary Containment, is not released to the surrounding atmosphere.
_____ C.        Secondary Containment Control EOP Leg to limit the maximum temperatures for equipment located in the Secondary Containment which is necessary to place the plant in a stable shutdown condition.
_____ D.        Radiation Release Control EOP Leg to place the plant in a condition which reduces the motive force for radioactive material release from inside the Secondary Containment to the environs.
Correct Answer : B High Drywell Pressure indication implies that Reactor Building Ventilation has tripped and isolated. Low Secondary Containment D/P requires Secondary Containment Control EOP Entry to ensure that any airborne radioactive material in the Secondary Containment is not released to the surrounding atmosphere without passing through the SGTS filters.


_____ A. Radiation Release Control EOP Leg to ensure that any airborne radioactive material, in the Secondary Containment, is not released to the surrounding  atmosphere.
_____ B. Secondary Containment Control EOP Leg to ensure that unfiltered airborne  radioactive material, in the Secondary Containment, is not released to the  surrounding atmosphere.     
_____ C. Secondary Containment Control EOP Leg to limit the maximum temperatures for equipment located in the Secondary Containment which is necessary to place the plant in a stable shutdown condition.
_____ D. Radiation Release Control EOP Leg to place the plant in a condition which reduces the motive force for radioactive material release from inside the Secondary Containment to the environs.
Correct Answer :  B High Drywell Pressure indication implies that Reactor Building Ventilation has tripped and isolated. Low Secondary Containment D/P re quires Secondary Containment Control EOP Entry to ensure that any airborne radioactive material in the Secondary Containment is not released to the surrounding atmosphere without passing through the SGTS filters.
2006 Fermi-2 NRC RO License Exam - Retake Plausible Distractors:
2006 Fermi-2 NRC RO License Exam - Retake Plausible Distractors:
A is plausible, Radiation Release EOP Leg may be required AFTER radioactivity is released without passing through the SGTS filters.
A is plausible, Radiation Release EOP Leg may be required AFTER radioactivity is released without passing through the SGTS filters.
C is plausible, High Area Temperatures is a Secondary Containment Control EOP Leg entry, but SGTS does not effectively limit Area Temperatures, due to having no supply cooling. D is plausible, radiation releases may be lim ited by reducing plant pressure, which reduces steam leakage and motive force. NO radi ation release conditions are given.
C is plausible, High Area Temperatures is a Secondary Containment Control EOP Leg entry, but SGTS does not effectively limit Area Temperatures, due to having no supply cooling.
Objective Link: LP-OP-315-0120-C011  
D is plausible, radiation releases may be limited by reducing plant pressure, which reduces steam leakage and motive force. NO radiation release conditions are given.
 
Objective Link: LP-OP-315-0120-C011
2006 Fermi-2 NRC RO License Exam - Retake RO 53 Tier 2 K/A Number 262001 Statement A2.02 IR 3.6 Origin B Source Question N/A LOK H (2RI/ 3PEO) Grp 1 10 CFR 55.41(b) 7 LOD (1-5) 2.3 Reference Documents 23.307, Rev. 90 QUESTION 56


The following conditions exist:
2006 Fermi-2 NRC RO License Exam - Retake RO      Tier        K/A Number            Statement    IR    Origin    Source Question 53      2              262001              A2.02      3.6      B      N/A LOK      Grp      10 CFR 55.41(b) 7      LOD (1-5)    Reference Documents H (2RI/      1                                    2.3      23.307, Rev. 90 3PEO)
QUESTION 56 The following conditions exist:
* Reactor power is 98%.
* Reactor power is 98%.
* Drywell Pressure is 1.1 psig, rising slowly.
* Drywell Pressure is 1.1 psig, rising slowly.
* Reactor Water Level is 185 inches, lowering slowly.
* Reactor Water Level is 185 inches, lowering slowly.
If the pressure and level trends continue, wh at can the operator expect to happen to the Emergency Diesel Generators (EDG), AND what action should be taken?  
If the pressure and level trends continue, what can the operator expect to happen to the Emergency Diesel Generators (EDG), AND what action should be taken?
 
_____ A.       EDG will auto start. Dispatch an operator to load the EDG for at least 1 hour.
_____ A. EDG will auto start. Dispatch an operator to load the EDG for at least 1 hour.  
_____ B.       EDG auto starts, load shed occurs. Dispatch an operator to load the EDG for at least 1 hour.
 
_____ C.       EDG will auto start and the EDG output breaker will close. Dispatch an operator to verify proper operation of the EDG.
_____ B. EDG auto starts, load shed occurs. Di spatch an operator to load the EDG for at least 1 hour.  
_____ D.      EDG will auto start, the EDG output breaker will close, and loads will be sequenced on to the EDG. Dispatch an operator to verify proper operation of the EDG.
 
Correct Answer : A BOTH Low RPV Water Level 1 and High Drywell Pressure will automatically start EDGs.
_____ C. EDG will auto start and the EDG output breaker will close. Dispatch an operator   to verify proper operation of the EDG.  
Since Offsite Power has not been lost, EDG will run unloaded with the Output Breaker open.
Procedure 23.307 requires loading for at least 1 hour before stopping an automatically started EDG.
Plausible Distractors:
B is plausible, Loads wont shed without a loss of power. Offsite Power is available, so no Load Shed will occur.
C is plausible, EDG will auto start. Offsite Power is available, so EDG Output Breaker will


_____ D. EDG will auto start, the EDG output breaker will close, and loads will be    sequenced on to the EDG. Dispatch an operator to verify proper operation of the    EDG.  
2006 Fermi-2 NRC RO License Exam - Retake not close.
D is plausible, EDG will auto start. Offsite Power is available, so EDG Output Breaker will not close.
Objective Link: ST-OP-315-0065-B003


Correct Answer : A  BOTH Low RPV Water Level 1 and High Drywell Pressure will automatically start EDGs. Since Offsite Power has not been lost, EDG will run unloaded with the Output Breaker open.
2006 Fermi-2 NRC RO License Exam - Retake RO       Tier         K/A Number           Statement      IR    Origin  Source Question 54        2              262002             A3.01       2.8     N     N/A LOK       Grp       10 CFR 55.41(b) 7       LOD (1-5)     Reference Documents H (2RI)      1                                    3.2       23.308.01, Rev. 25 QUESTION 57 The following indications exist:
Procedure 23.307 requires loading for at least 1 hour before stopping an automatically started EDG. Plausible Distractors:
 
B is plausible, Loads won't shed without a loss of power. Offsite Power is available, so no Load Shed will occur.
C is plausible, EDG will auto start. Offsite Power is available, so EDG Output Breaker will 2006 Fermi-2 NRC RO License Exam - Retake not close. D is plausible, EDG will auto start. Offsite Power is available, so EDG Output Breaker will not close.
Objective Link:  ST-OP-315-0065-B003 2006 Fermi-2 NRC RO License Exam - Retake RO 54 Tier 2 K/A Number 262002 Statement A3.01 IR 2.8 Origin N Source Question N/A LOK H (2RI) Grp 1 10 CFR 55.41(b) 7 LOD (1-5) 3.2 Reference Documents 23.308.01, Rev. 25 QUESTION 57
 
The following indications exist:
* 3D22, UPS UNIT A / B TROUBLE, alarms.
* 3D22, UPS UNIT A / B TROUBLE, alarms.
* Reactor Building Operator reports that R3100S011, UPS Bus "A" Inverter DC Input Breaker, is OPEN.
* Reactor Building Operator reports that R3100S011, UPS Bus A Inverter DC Input Breaker, is OPEN.
 
Given these indications, which one of the following describes UPS distribution status?
Given these indications, which one of the following describes UPS distribution status?  
_____ A.       UPS Bus A loads are de-energized, the DC Input Breaker must be repaired to restore power to UPS Bus A loads.
 
_____ B.       UPS Bus A loads remain energized, the STATIC SWITCH automatically aligns loads to the Alternate Source.
_____ A. UPS Bus "A" loads are de-energized, th e DC Input Breaker mu st be repaired to restore power to UPS Bus "A" loads.  
_____ C.       UPS Bus A loads are de-energized, MANUAL TRANSFER Switch operation is necessary to restore power to UPS Bus A loads.
 
_____ D.       UPS Bus A loads remain energized, the STATIC SWITCH automatically aligns inverter to the UPS Bus B Rectifier Output.
_____ B. UPS Bus "A" loads remain energized, the STATIC SWITCH automatically   aligns loads to the Alternate Source.  
 
_____ C. UPS Bus "A" loads are de-energi zed, MANUAL TRANSFER Switch operation is   necessary to restore power to UPS Bus "A" loads.
_____ D. UPS Bus "A" loads remain energized, the STATIC SWITCH automatically aligns inverter to the UPS Bus "B" Rectifier Output.  
 
Correct Answer : B A low voltage output is sensed at the output of the static inverter and the STATIC SWITCH automatically aligns loads to the Alternate Source.
Correct Answer : B A low voltage output is sensed at the output of the static inverter and the STATIC SWITCH automatically aligns loads to the Alternate Source.
Plausible Distractors:
Plausible Distractors:
A is plausible, UPS Inverters A and B can shar e DC, but if Inverter "A" DC Input Breaker trips, the UPS "A" Inverter will have no power.
A is plausible, UPS Inverters A and B can share DC, but if Inverter A DC Input Breaker trips, the UPS A Inverter will have no power.
C is plausible, if Inverter and Static Switch are damaged, this is the appropriate method.
C is plausible, if Inverter and Static Switch are damaged, this is the appropriate method.
D is plausible, DC Input Power is shared be tween UPS "A" and "B", AC Output is not.
D is plausible, DC Input Power is shared between UPS A and B, AC Output is not.
Objective Link: ST-OP-315-0062-B003  
Objective Link: ST-OP-315-0062-B003


2006 Fermi-2 NRC RO License Exam - Retake RO 55 Tier 2 K/A Number 263000 Statement A4.01 IR 3.3 Origin N Source Question N/A LOK F (1I) Grp 1 10 CFR 55.41(b) 7 LOD (1-5) 2.75 Reference Documents 20.300.260VESF, Rev 1 QUESTION 58
2006 Fermi-2 NRC RO License Exam - Retake RO       Tier         K/A Number           Statement      IR  Origin    Source Question 55        2              263000             A4.01       3.3     N       N/A LOK       Grp       10 CFR 55.41(b) 7       LOD (1-5)     Reference Documents F (1I)      1                                    2.75     20.300.260VESF, Rev 1 QUESTION 58 With a loss of Division 1 ESF 260/130 VDC Batteries and Chargers, which one of the following will result?
_____ A.        Breakers on 4160V Busses 65E and 13EC will lose control power.
_____ B.      C11-F110A, Scram Pilot Air Header Backup Scram Valve, will actuate.
_____ C.      MCC 72CF Feed will auto throw-over from 72C Pos 3C to 72F Pos 5C.
_____ D.      Breakers CM and CF will not open on generator relaying or with the manual control switches on COP H11-P804.
Correct Answer : C Div 1 ESF Batteries provide control power to Div 1 ESF buses, breakers, and MCC 72CF Breaker auto throw-over function. (This is the LPCI Swing MCC.) There are no Control Room operated DC Power Breakers. Loss of Div 1 control power will cause MCC 72CF to shift from being supplied from Div 1 to Div 2 power.
Plausible Distractors:
A is plausible, but is associated with Division 2 ESF 260 / 130 VDC Batteries and Chargers.
B is plausible, correct source, but loss of power prevents Backup Scram Valve actuation.
D is plausible, but is a failure mode associated with loss of BOP Batteries and Chargers.
Objective Link: ST-OP-315-0064-A016


With a loss of Division 1 ESF 260/130 VDC Batteries and Chargers, which one of the following will result?
2006 Fermi-2 NRC RO License Exam - Retake RO       Tier         K/A Number           Statement    IR    Origin  Source Question 57        2            300000               K1.05     3.1     N     N/A LOK       Grp     10 CFR 55.41(b) 7       LOD (1-5)   Reference Documents H (2RI/      1                                  2.7     20.129.01, Rev 25 3PEO)
 
QUESTION 59 The plant is operating at 100% power, when the following occurs:
_____ A. Breakers on 4160V Busses 65E and 13EC will lose control power.
 
_____ B. C11-F110A, Scram Pilot Air Header Backup Scram Valve, will actuate. 
 
_____ C. MCC 72CF Feed will auto throw-over from 72C Pos 3C to 72F Pos 5C.
 
_____ D. Breakers CM and CF will not open on generator relaying or with the manual  control switches on COP H11-P804.
 
Correct Answer : C Div 1 ESF Batteries provide control power to Div 1 ESF buses, breakers, and MCC 72CF Breaker auto throw-over function.  (This is the LPCI Swing MCC.)  There are no Control Room operated DC Power Breakers. Loss of Div 1 control power will cause MCC 72CF to shift from being supplied from Div 1 to Div 2 power.
Plausible Distractors:
 
A is plausible, but is associated with Division 2 ESF 260 /
130 VDC Batteries and Chargers.
B is plausible, correct source, but loss of power prevents Backup Scram Valve actuation. D is plausible, but is a failure mode associated with loss of BOP Batteries and Chargers.
Objective Link:  ST-OP-315-0064-A016 2006 Fermi-2 NRC RO License Exam - Retake RO 57 Tier 2 K/A Number 300000 Statement K1.05 IR 3.1 Origin N Source Question N/A LOK H (2RI/ 3PEO) Grp 1 10 CFR 55.41(b) 7 LOD (1-5) 2.7 Reference Documents 20.129.01, Rev 25 QUESTION 59  
 
The plant is operating at 100% pow er, when the following occurs:
* 7D54, INTERRUPTIBLE CONTROL AIR HEADER PRESS LOW, alarms.
* 7D54, INTERRUPTIBLE CONTROL AIR HEADER PRESS LOW, alarms.
* P50-R870, IAS Header Pressure Indi cator, reads 80 psig (lowering).
* P50-R870, IAS Header Pressure Indicator, reads 80 psig (lowering).
If this trend continues, which one of the following describes the component(s)
If this trend continues, which one of the following describes the component(s) AND failure mode(s) which will require the Reactor Mode Switch to be placed in SHUTDOWN per 20.129.01, Loss of Station and/or Control Air?
AND failure mode(s) which will require the Reactor Mode Switch to be placed in SHUTDOWN per 20.129.01, "Loss of Station and/or Control Air"?  
_____ A.       An Inboard MSIV begins to CLOSE due to loss of IAS.
 
_____ B.       An Outboard MSIV begins to CLOSE due to loss of IAS.
_____ A. An Inboard MSIV begins to CLOSE due to loss of IAS.  
_____ C.       A Control Rod drifts in due to C11-F002A, CRD Flow Control Valve, failing OPEN due to loss of IAS.
 
_____ D.       A Control Rod Drive Hydraulic Pump TRIPS on Low Suction Pressure due to C11-F412, CRD Pump Suction Pressure Control Valve, failing SHUT due to loss of IAS.
_____ B. An Outboard MSIV begins to CLOSE due to loss of IAS.
_____ C. A Control Rod drifts in due to C 11-F002A, CRD Flow Control Valve, failing   OPEN due to loss of IAS.
_____ D. A Control Rod Drive Hydraulic Pump TRIPS on Low Suction Pressure due to   C11-F412, CRD Pump Suction Pressure Control Valve, failing SHUT due to loss   of IAS.  
 
Correct Answer : B Outboard MSIVs are supplied by IAS and close at approximately 50 psig.
Correct Answer : B Outboard MSIVs are supplied by IAS and close at approximately 50 psig.
Plausible Distractors:   A is plausible, Inboard MSIVs may begin to CLOSE, if Division 1 Non Interruptible Air is lost.
Plausible Distractors:
A is plausible, Inboard MSIVs may begin to CLOSE, if Division 1 Non Interruptible Air is lost.
C is plausible, failure mode of C11-F002A is CLOSED, so Control Rods will not drift in due to this failure.
C is plausible, failure mode of C11-F002A is CLOSED, so Control Rods will not drift in due to this failure.
D is plausible, although complete loss of CRD may require the Reactor Mode Switch placed in 2006 Fermi-2 NRC RO License Exam - Retake SHUTDOWN immediately during some other plant conditions, the CST provides a redundant suction supply to the CRD Hydraulic Pumps. The operating CRD Pump should remain in service. Objective Link:  SS-OP-802-2001-RO-0004 2006 Fermi-2 NRC RO License Exam - Retake RO 58 Tier 2 K/A Number 400000 Statement K2.01 IR 2.9 Origin N Source Question N/A LOK F (1F) Grp 1 10 CFR 55.41(b) 7 LOD (1-5) 2.75 Reference Documents 23.127, Rev 103
D is plausible, although complete loss of CRD may require the Reactor Mode Switch placed in


QUESTION 60
2006 Fermi-2 NRC RO License Exam - Retake SHUTDOWN immediately during some other plant conditions, the CST provides a redundant suction supply to the CRD Hydraulic Pumps. The operating CRD Pump should remain in service.
Objective Link: SS-OP-802-2001-RO-0004


With the plant operating at 100% po wer, when the following occurs:
2006 Fermi-2 NRC RO License Exam - Retake RO      Tier        K/A Number          Statement    IR    Origin  Source Question 58        2            400000              K2.01      2.9      N    N/A LOK      Grp      10 CFR 55.41(b) 7      LOD (1-5)    Reference Documents F (1F)      1                                  2.75      23.127, Rev 103 QUESTION 60 With the plant operating at 100% power, when the following occurs:
* 9D10, DIV 1 480 V ESS BUS 72C BKR TRIPPED, alarms.
* 9D10, DIV 1 480 V ESS BUS 72C BKR TRIPPED, alarms.
* CMC Switch for BUS 64C POS C11, 4160V F EED TO BUS 72C, indicates TRIPPED.
* CMC Switch for BUS 64C POS C11, 4160V FEED TO BUS 72C, indicates TRIPPED.
Given these indications, which of the following correctly describes the impact on the Reactor Building Closed Cooling Water (RBCCW) Pumps?
Given these indications, which of the following correctly describes the impact on the Reactor Building Closed Cooling Water (RBCCW) Pumps?
 
_____ A.       ONLY P4200-C001, North RBCCW Pump, loses power.
_____ A.
_____ B.       ONLY P4200-C003, South RBCCW Pump, loses power.
ONLY P4200-C001, North RBCCW Pump, loses power.
_____ C.       BOTH P4200-C001 AND P4200-C002, North and Center RBCCW Pumps, lose power.
 
_____ D.       BOTH P4200-C003 AND P4200-C002, South and Center RBCCW Pumps, lose power.
_____ B.
Correct Answer : A Bus 72C is the power supply to the North RBCCW Pump.
ONLY P4200-C003, South RBCCW Pump, loses power.
Plausible Distractors:
_____ C.
B is plausible, P4200-C003, South RBCCW Pump is powered from Bus 72E.
BOTH P4200-C001 AND P4200-C002, North and Center RBCCW   Pumps, lose power.
_____ D.
BOTH P4200-C003 AND P4200-C002, South and Center RBCCW   Pumps, lose power.  
 
Correct Answer : A Bus 72C is the power supply to the North RBCCW Pump.
Plausible Distractors: B is plausible, P4200-C003, South RBCCW Pump is powered from Bus 72E.  
 
C/D is plausible, P4200-C002, Center RBCCW Pump is powered from Bus 72F.
C/D is plausible, P4200-C002, Center RBCCW Pump is powered from Bus 72F.
Objective Link: ST-OP-315-0067-A014 2006 Fermi-2 NRC RO License Exam - Retake RO 60 Tier 2 K/A Number 212000  Statement A1.04  IR 2.8 Origin N Source Question N/A LOK H (3PEO) Grp 1 10 CFR 55.41(b) 7 LOD (1-5) 2.8 Reference Documents 23.316, Rev 46 QUESTION 61 
Objective Link: ST-OP-315-0067-A014


With the plant operating with normal electrical alignment at 100% power, RPS Bus "A" Voltage begins lowering. The FIRST protective action which will result is a trip of the:
2006 Fermi-2 NRC RO License Exam - Retake RO      Tier          K/A Number          Statement      IR    Origin  Source Question 60        2              212000            A1.04        2.8    N      N/A LOK      Grp    10 CFR 55.41(b) 7        LOD (1-5)      Reference Documents H        1                                  2.8        23.316, Rev 46 (3PEO)
QUESTION 61 With the plant operating with normal electrical alignment at 100% power, RPS Bus A Voltage begins lowering. The FIRST protective action which will result is a trip of the:
_____ A.      RPS MG Set A Motor Breaker.
_____ B.      RPS MG Set A Output Breaker.
_____ C.      C7100-S003C, RPS MG Set A EPA Circuit Breaker.
_____ D.      C7100-S003G, RPS Alternate Transformer A EPA Circuit Breaker.
Correct Answer : C C7100-S003C, EPA Circuit Breaker trips at 109 VAC.
High Cognitive Level due to recognizing normal RPS alignment and breaker trip hierarchy.
Plausible Distractors:
A s plausible, only Motor trips are 175 amps, loss of 480 vac power, and overheating 230&deg;F.
B is plausible, but is not the FIRST., Output Breaker trips at 108 VAC.
D is plausible, this is the RPS A Alternate Power EPA, not normally in service.
Objective Link: ST-OP-315-0027-A008


_____ A. RPS MG Set "A" Motor Breaker.  
2006 Fermi-2 NRC RO License Exam - Retake RO      Tier          K/A Number            Statement  IR    Origin  Source Question 61        2              215003              K3.01    3.9      N    N/A LOK      Grp        10 CFR 55.41(b) 7        LOD (1-5)  Reference Documents H        1                                    2.7    3D59, Rev 6 (3PEO)                                                    3D63, Rev 5 QUESTION 62 During a reactor start-up with all IRMs reading 30 on Range 5, IRM E Range Selector Switch is repositioned to Range 4.
 
This will cause a:
_____ B. RPS MG Set "A" Output Breaker.
_____ A.      Rod Block ONLY.
_____ C. C7100-S003C, RPS MG Set "A" EPA Circuit Breaker.
_____ B.       Half Scram ONLY.
_____ D. C7100-S003G, RPS Alternate Transformer "A" EPA Circuit Breaker.  
_____ C.       Half Scram on RPS Trip Channel A AND a Rod Block.
_____ D.       Half Scram on RPS Trip Channel B AND a Rod Block.
Correct Answer : C When E IRM Range switch is repositioned to Range 4, indication goes from 30/40 to 300/125, which results in an IRM High-High condition. This results in a RPS Trip Channel A Trip and a Rod Block.
Plausible Distractors:
A is plausible, but is only partially correct.
B is plausible, but is only partially correct.
D is plausible, but incorrect, RPS Trip Channel A is associated with IRM E.
Objective Link: ST-OP-315-0023-B002 NRC NOTE: Based on questions asked by candidates during the written exam, the licensee changed the highlighted numbers. The reason for the change: odd ranges for IRMs are 0 - 40!


Correct Answer : C C7100-S003C, EPA Circuit Breaker trips at 109 VAC.
2006 Fermi-2 NRC RO License Exam - Retake RO      Tier          K/A Number          Statement      IR    Origin Source Question 62        2              262001            K5.01        3.1    N    N/A LOK      Grp    10 CFR 55.41(b) 7        LOD (1-5)      Reference Documents H        1                                  2.9        23.307, Rev 90 (3PEO)
High Cognitive Level due to recognizing normal RPS alignment and brea ker trip hierarchy.
QUESTION 63 When paralleling an EDG with Offsite Power, if SYNCH BUS Starting Volts are 12 volts higher than SYNCH BUS Running Volts, which one of the following conditions will result when the EDG Output Breaker is CLOSED?
_____ A.      The Emergency Diesel Generator will be reverse powered by the grid.
_____ B.      Excessive Reactive Power will flow from the Emergency Diesel Generator to the grid.
_____ C.      Excessive Reactive Power will flow from the grid to the Emergency Diesel Generator.
_____ D.      Excessive True Power will be picked up from the grid by the Emergency Diesel Generator.
Correct Answer : B KA Statement, principles of paralleling two AC sources KA tie is the proper division of reactive load by adjustment of pre-synchronization settings. Approximate voltage match.
Plausible Distractors:
Plausible Distractors:
A s plausible, only Motor trips are 175 amps, loss of 480 vac power, and overheating 230
A is plausible, will happen if Governor Setting is too low.
&deg;F. B is plausible, but is not the FIRS T., Output Breaker trips at 108 VAC. D is plausible, this is the RPS "A" Alternate Power EPA, not normally in service.
Objective Link:  ST-OP-315-0027-A008
 
2006 Fermi-2 NRC RO License Exam - Retake RO 61 Tier 2 K/A Number 215003 Statement K3.01 IR 3.9 Origin N Source Question N/A LOK H (3PEO) Grp 1 10 CFR 55.41(b) 7 LOD (1-5) 2.7 Reference Documents 3D59, Rev 6
 
3D63, Rev 5 QUESTION 62
 
During a reactor start-up with all IRMs reading 30 on Range 5, IRM E Range Selector Switch is repositioned to Range 4.
 
This will cause a:
 
_____ A. Rod Block ONLY.
_____ B. Half Scram ONLY. _____ C. Half Scram on RPS Trip Channel "A" AND a Rod Block.
_____ D. Half Scram on RPS Trip Channel "B" AND a Rod Block.
 
Correct Answer :  C When E IRM Range switch is repositioned to Range 4, indication goes from 30/40 to 300/125, which results in an IRM High-High condition. Th is results in a RPS Trip Channel "A" Trip and a Rod Block.
Plausible Distractors: 
 
A is plausible, but is only partially correct.
 
B is plausible, but is only partially correct.
 
D is  plausible, but incorrect, RPS Trip Channel A is associated with IRM E.
Objective Link:  ST-OP-315-0023-B002 NRC NOTE:  Based on questions asked by candidates during the written exam, the licensee changed the highlighted numbers. The reas on for the change: odd ranges for IRMs are 0 - 40!
2006 Fermi-2 NRC RO License Exam - Retake RO 62 Tier 2 K/A Number 262001 Statement K5.01 IR 3.1 Origin N Source Question N/A LOK H (3PEO)  Grp 1 10 CFR 55.41(b) 7 LOD (1-5) 2.9 Reference Documents 23.307, Rev 90 QUESTION 63
 
When paralleling an EDG with Offsite Power, if SYNCH BUS Starting Volts are 12 volts higher
 
than SYNCH BUS Running Volts, which one of the following conditions will result when the EDG Output Breaker is CLOSED?
 
_____ A. The Emergency Diesel Generator will be reverse powered by the grid.
 
_____ B. Excessive Reactive Power will flow from the Emergency Diesel Generator to the grid.
_____ C. Excessive Reactive Power will flow from the grid to the Emergency Diesel Generator.
 
_____ D. Excessive True Power will be picked up from the grid by the Emergency Diesel Generator.
 
Correct Answer :  B KA Statement, "principles of paralleling two AC sources" KA tie is the proper division of reactive load by adjustment of pre-synchronization settings. Approximate voltage match.
Plausible Distractors:    A is plausible, will happen if Governor Setting is too low.
C is plausible, will happen if Voltage Regulator Setting is too low.
C is plausible, will happen if Voltage Regulator Setting is too low.
D is plausible, will happen if Governor Setting is too high.
D is plausible, will happen if Governor Setting is too high.
Objective Link: ST-OP-315-0065-A016  
Objective Link: ST-OP-315-0065-A016
 
2006 Fermi-2 NRC RO License Exam - Retake RO 64 Tier 2 K/A Number 201001 Statement A1.01 IR 3.1 Origin B Source Question 2004 Clinton NRC Exam LOK H (3PEO) Grp 2 10 CFR 55.41(b) 5 LOD (1-5) 2.8 Reference Documents ST-OP-315-0010, Rev 14 QUESTION 64
 
The plant is operating at normal pressure with C11-F002A, CRD Drive Wa ter "A" Flow Control Valve, in service and in AUTOMATIC control. 


2006 Fermi-2 NRC RO License Exam - Retake RO      Tier          K/A Number          Statement      IR    Origin  Source Question 64        2              201001              A1.01      3.1      B    2004 Clinton NRC Exam LOK      Grp        10 CFR 55.41(b) 5      LOD (1-5)    Reference Documents H        2                                    2.8      ST-OP-315-0010, Rev 14 (3PEO)
QUESTION 64 The plant is operating at normal pressure with C11-F002A, CRD Drive Water A Flow Control Valve, in service and in AUTOMATIC control.
The following CRD indications are present:
The following CRD indications are present:
* Cooling water flow is 45 gpm.
* Cooling water flow is 45 gpm.
Line 1,472: Line 1,094:
* Cooling water D/P is 15 psid.
* Cooling water D/P is 15 psid.
* No Control Rod Motion is in progress.
* No Control Rod Motion is in progress.
When C1152-F003, CRD Drive/Cooling Water Pre ssure Control Valve, is adjusted in the CLOSED direction, what will be the FINAL effect on the CRD System parameters?  
When C1152-F003, CRD Drive/Cooling Water Pressure Control Valve, is adjusted in the CLOSED direction, what will be the FINAL effect on the CRD System parameters?
 
_____ A.       Drive Water D/P INCREASES and Cooling Water Flow DECREASES.
_____ A. Drive Water D/P INCREASES and Cooling Water Flow DECREASES. _____ B. Drive Water D/P DECREASES and Cooling Water Flow DECREASES. _____ C. Drive Water D/P INCREASES and Cooling Water Flow REMAINS THE SAME.
_____ B.       Drive Water D/P DECREASES and Cooling Water Flow DECREASES.
_____ D. Drive Water D/P DECREASES and Cooling Water Flow REMAINS THE SAME.
_____ C.       Drive Water D/P INCREASES and Cooling Water Flow REMAINS THE SAME.
Correct Answer : C When the Pressure Control Valve is throttled CLOSED, Drive Water D/P increases, due to lower flow through the CRD Pump. The FCV is in AUTO and automatically maintains Cooling Water Flow stable.
_____ D.       Drive Water D/P DECREASES and Cooling Water Flow REMAINS THE SAME.
Correct Answer : C When the Pressure Control Valve is throttled CLOSED, Drive Water D/P increases, due to lower flow through the CRD Pump. The FCV is in AUTO and automatically maintains Cooling Water Flow stable.
Plausible Distractors:
Plausible Distractors:
A is plausible, but is incorrect because cooling water flow remains the same with FCV in AUTO. Correct if the CRD FCV was in MANUAL.  
A is plausible, but is incorrect because cooling water flow remains the same with FCV in AUTO. Correct if the CRD FCV was in MANUAL.
B/D is plausible, but is incorrect because drive water D/P increases. Could be selected if misconception exists about location of PCV. (For example: If PCV was located upstream of


B/D is plausible, but is incorrect because driv e water D/P increases.
2006 Fermi-2 NRC RO License Exam - Retake Cooling Water Header.)
Could be selected if misconception exists about location of PCV.  (For example: If PCV was located upstream of 2006 Fermi-2 NRC RO License Exam - Retake Cooling Water Header.)
Objective Link: ST-OP-315-0010-A015
Objective Link: ST-OP-315-0010-A015 2006 Fermi-2 NRC RO License Exam - Retake RO 65 Tier 2 K/A Number 202002 Statement 2.1.28 IR 3.2 Origin N Source Question N/A LOK F (1P) Grp 2 10 CFR 55.41(b) 7 LOD (1-5) 3.2 Reference Documents 23.138.01, Rev 88 QUESTION 65


The RECIRC MANUAL RUNBACK pushbu tton causes a speed reduction in:  
2006 Fermi-2 NRC RO License Exam - Retake RO      Tier        K/A Number          Statement    IR    Origin  Source Question 65        2            202002            2.1.28      3.2    N      N/A LOK      Grp      10 CFR 55.41(b) 7      LOD (1-5)    Reference Documents F (1P)      2                                  3.2      23.138.01, Rev 88 QUESTION 65 The RECIRC MANUAL RUNBACK pushbutton causes a speed reduction in:
 
_____ A.       ONLY RR MG Sets in AUTO and automatically resets when the RR MG Set speed adjustments are completed.
_____ A.
_____ B.       RR MG Sets in AUTO or MANUAL and automatically resets when the RR MG Set speed adjustments are completed.
ONLY RR MG Sets in AUTO and automatically resets when the RR MG Set   speed adjustments are completed.  
_____ C.       ONLY RR MG Sets in AUTO and is RESET by operation of the RECIRC RUNBACK RESET A (B) pushbutton.
 
_____ D.       RR MG Sets in AUTO or MANUAL, and is RESET by operation of the RECIRC RUNBACK RESET A (B) pushbutton.
_____ B. RR MG Sets in AUTO or MANUAL and automatically resets when the RR MG Set speed adjustments are completed.
Correct Answer : B RECIRC RUNBACK RESET A (B) pushbutton is used to reset automatic runbacks from the speed limiters. Manual Runbacks automatically reset when speed adjustments are completed.
_____ C. ONLY RR MG Sets in AUTO and is RESET by operation of the RECIRC   RUNBACK RESET A (B) pushbutton.  
Plausible Distractors:
 
A is plausible, Manual Runbacks automatically reset when speed adjustments are completed.
_____ D. RR MG Sets in AUTO or MANUAL, and is RESET by operation of the RECIRC RUNBACK RESET A (B) pushbutton.  
Misconception may exist that speeds are only reduced in Auto.
 
C is plausible, RR MG Set speeds are reduced in Auto or Manual. Misconception may exist that speeds are only reduced in Auto.
Correct Answer : B RECIRC RUNBACK RESET A (B) pus hbutton is used to reset automatic runbacks from the speed limiters. Manual Runbacks automatically reset when speed adjustments are completed.
Plausible Distractors:   A is plausible, Manual Runbacks automatically reset when speed adjustments are completed.
Misconception may exist that speeds are only reduced in Auto. C is plausible, RR MG Set speeds are reduced in Auto or Manual. Misconception may exist that speeds are only reduced in Auto.
D is plausible, RR MG Set speeds are reduced in Auto or Manual. Manual Runbacks automatically reset when speed adjustments are completed.
D is plausible, RR MG Set speeds are reduced in Auto or Manual. Manual Runbacks automatically reset when speed adjustments are completed.
Objective Link: ST-OP-315-0004-C001  
Objective Link: ST-OP-315-0004-C001


2006 Fermi-2 NRC RO License Exam - Retake RO 66 Tier 2 K/A Number 204000 Statement K1.08 IR 3.7 Origin B Source Question LaSalle 2003 NRC Exam LOK F (1I) Grp 2 10 CFR 55.41(b) 7 LOD (1-5) 2.3 Reference Documents 23.139, Rev 41 QUESTION 66
2006 Fermi-2 NRC RO License Exam - Retake RO       Tier         K/A Number           Statement    IR    Origin    Source Question 66        2              204000               K1.08     3.7     B     LaSalle 2003 NRC Exam LOK       Grp   10 CFR 55.41(b) 7           LOD (1-5)   Reference Documents F (1I)      2                                    2.3     23.139, Rev 41 QUESTION 66 Which of the following describes the DIRECT response of the Reactor Water Cleanup System when the Standby Liquid Control System is initiated?
 
_____ A.       The operating RWCU pumps trip.
Which of the following describes the DIRECT response of the Reactor Water Cleanup System when the Standby Liquid Control System is initiated?  
_____ B.       The operating RWCU Filter Demineralizers go into HOLD.
 
_____ C.       G3300-F033, RWCU Blowdown Flow Control Valve, automatically closes.
_____ A. The operating RWCU pumps trip.  
_____ D.       G3352-F004, RWCU Supply Outboard Isolation Valve, AND G3352-F220, RWCU to Feedwater Outboard Containment Isolation Valve, CLOSE.
 
Correct Answer : D SBLC Initiation directly causes G3352-F004, RWCU Supply Outboard Isolation Valve AND G3352-F220, RWCU to Feedwater Outboard Containment Isolation Valve to CLOSE.
_____ B. The operating RWCU Filter Demineralizers go into HOLD.
 
_____ C. G3300-F033, RWCU Blowdown Flow Control Valve, automatically closes.  
 
_____ D. G3352-F004, RWCU Supply Ou tboard Isolation Valve, AND G3352-F220, RWCU to Feedwater Outboard Containment Isolation Valve, CLOSE.
Correct Answer : D SBLC Initiation directly cause s G3352-F004, RWCU Supply Ou tboard Isolation Valve AND G3352-F220, RWCU to Feedwater Outboard Containment Isolation Valve to CLOSE.
Plausible Distractors:
Plausible Distractors:
A is plausible, this is an i ndirect trip, on G3352-F004 Not Full Open. Valve gets close signal and closes, leaving full open limit switch (5% clos ed/95% open). Full open contact in pump trip string, closes, tripping the pump.
A is plausible, this is an indirect trip, on G3352-F004 Not Full Open. Valve gets close signal and closes, leaving full open limit switch (5% closed/95% open). Full open contact in pump trip string, closes, tripping the pump.
B is plausible, this is an indirect effect. Sensed Low F/D Flow will cause F/Ds to transfer to HOLD. C is plausible, but is NOT an interlock associated with SBLC.
B is plausible, this is an indirect effect. Sensed Low F/D Flow will cause F/Ds to transfer to HOLD.
Objective Link: ST-OP-315-0008-B007  
C is plausible, but is NOT an interlock associated with SBLC.
 
Objective Link: ST-OP-315-0008-B007
2006 Fermi-2 NRC RO License Exam - Retake RO 67 Tier 2 K/A Number 215002 Statement K2.03 IR 2.8 Origin N Source Question N/A LOK H (3PEO) Grp 2 10 CFR 55.41(b) 7 LOD (1-5) 3.5 Reference Documents 9D70, Rev 16, VMR1-82.1 QUESTION 67 


With the plant operating at 100%
2006 Fermi-2 NRC RO License Exam - Retake RO      Tier        K/A Number          Statement      IR    Origin  Source Question 67        2            215002            K2.03        2.8      N      N/A LOK      Grp    10 CFR 55.41(b) 7        LOD (1-5)      Reference Documents H        2                                  3.5        9D70, Rev 16, VMR1-82.1 (3PEO)
power, the following occur:
QUESTION 67 With the plant operating at 100% power, the following occur:
* 3D103, APRM TROUBLE, alarms.
* 3D103, APRM TROUBLE, alarms.
* 9D70, DIV I 120V RPS BUS 1A POWER FAILURE, alarms.
* 9D70, DIV I 120V RPS BUS 1A POWER FAILURE, alarms.
Which one of the following describes the impact of this failure?  
Which one of the following describes the impact of this failure?
 
_____ A.       ALL APRM Channels are operable AND a Half Scram has occurred.
_____ A.
_____ B.       APRM Channel 1 indicates INOP trip AND a Half Scram has occurred.
ALL APRM Channels are operable AND a Half Scram has occurred.
_____ C.       APRM Channels 1 and 3 indicate INOP trip AND a Full Scram has occurred.
 
_____ D.       ALL APRM Channels are operable AND ONLY a Control Rod Block has occurred.
_____ B. APRM Channel 1 indicates INOP trip AND a Half Scram has occurred.  
Correct Answer : A APRMs have a QLVPS powered from both RPS A and B in an auctioneered manner. Loss of one RPS power supply will cause a non-critical self-test fault only. No functions will be affected. Loss of RPS A side causes a half scram, not from APRMs.
 
Plausible Distractors:
_____ C. APRM Channels 1 and 3 indicate INOP trip AND a Full Scram has occurred.
B is plausible, based on former design of PRNM.
 
_____ D.
ALL APRM Channels are operable AND ONLY a Control Rod Block has   occurred.  
 
Correct Answer : A APRMs have a QLVPS powered from both RPS A and B in an auctioneered manner. Loss of one RPS power supply will cause a non-critical self-test fault only. No functions will be affected. Loss of RPS A side causes a half scram, not from APRMs.
Plausible Distractors: B is plausible, based on former design of PRNM.
C is plausible, based on former design of PRNM and misconception of new design requiring any 2 APRMs for a full scram.
C is plausible, based on former design of PRNM and misconception of new design requiring any 2 APRMs for a full scram.
D is plausible, APRMs are not affected. The Half scram is a result of the loss of RPS bus 1A.
D is plausible, APRMs are not affected. The Half scram is a result of the loss of RPS bus 1A.
Objective Link: ST-OP-315-0024-B002 2006 Fermi-2 NRC RO License Exam - Retake RO 56 Tier 2 K/A Number 264000 Statement 2.4.31 IR 3.3 Origin N Source Question N/A LOK H (2RI/ 3PEO) Grp 1 10 CFR 55.41(b) 7 LOD (1-5) 3.0 Reference Documents 9D44, Rev 4, 9D66, Rev 4 QUESTION 68
Objective Link: ST-OP-315-0024-B002


Following a Loss of Offsite Power, EDGs 11 and 12 are operating suppl ying their respective ESF Busses. The following alarms are received:
2006 Fermi-2 NRC RO License Exam - Retake RO      Tier        K/A Number            Statement      IR      Origin  Source Question 56        2            264000              2.4.31      3.3      N      N/A LOK      Grp  10 CFR 55.41(b) 7          LOD (1-5)    Reference Documents H (2RI/      1                                  3.0      9D44, Rev 4, 9D66, Rev 4 3PEO)
QUESTION 68 Following a Loss of Offsite Power, EDGs 11 and 12 are operating supplying their respective ESF Busses. The following alarms are received:
* 9D44, DIV I EDG 11 FUEL OIL PRESSURE LOW.
* 9D44, DIV I EDG 11 FUEL OIL PRESSURE LOW.
* 9D66, DIV I EDG 12 CRANKCASE PRESSURE HIGH.
* 9D66, DIV I EDG 12 CRANKCASE PRESSURE HIGH.
Given these indications, which one of the following describes the status of the Emergency Diesel Generators?  
Given these indications, which one of the following describes the status of the Emergency Diesel Generators?
 
_____ A.       BOTH EDGs trip immediately.
_____ A.
_____ B.       BOTH EDGs continue to operate.
BOTH EDGs trip immediately.
_____ C.       EDG 11 continues to operate. EDG 12 trips immediately.
 
_____ D.       EDG 11 trips immediately. EDG 12 continues to operate.
_____ B.
Correct Answer : C After an emergency start, only essential trips are active. Fuel oil low pressure is not an essential trip.
BOTH EDGs continue to operate.  
Plausible Distractors:
 
_____ C. EDG 11 continues to operate. EDG 12 trips immediately.  
 
_____ D. EDG 11 trips immediately.
EDG 12 continues to operate.  
 
Correct Answer : C After an emergency start, only essential trips are active. Fuel oil low pressure is not an essential trip.
Plausible Distractors:  
 
Other choices are plausible if EDG logic and/or essential and non-essential trips are not known.
Other choices are plausible if EDG logic and/or essential and non-essential trips are not known.
Objective Link: ST-OP-315-0065-B003 2006 Fermi-2 NRC RO License Exam - Retake RO 68 Tier 2 K/A Number 216000 Statement A2.08 IR 3.2 Origin N Source Question N/A LOK H (3SPR) Grp 2 10 CFR 55.41(b) 5 LOD (1-5) 3.5 Reference Documents Provide:  29.100.01, Rev 6 Cautions
Objective Link: ST-OP-315-0065-B003


and Curves QUESTION 69
2006 Fermi-2 NRC RO License Exam - Retake RO      Tier        K/A Number            Statement      IR    Origin  Source Question 68        2              216000              A2.08        3.2    N      N/A LOK      Grp    10 CFR 55.41(b) 5          LOD (1-5)      Reference Documents H        2                                    3.5      Provide: 29.100.01, Rev 6 Cautions (3SPR)                                                      and Curves QUESTION 69 A plant transient has resulted in the following conditions:
 
A plant transient has resulted in the following conditions:
* Reactor Pressure is 100 psig.
* Reactor Pressure is 100 psig.
* Drywell Temperature is 360&deg;F.
* Drywell Temperature is 360&deg;F.
B21-R605, RPV Flood Up Level Indicator, is   (1)   . The LOWEST value at which this instrument may be used is   (2)   .
B21-R605, RPV Flood Up Level Indicator, is         (1) . The LOWEST value at which this instrument may be used is (2) .
(1)     (2)  
(1)                                     (2)
 
_____ A.           accurate                   at an indicated RPV level of 200
_____ A. accurate   at an indicated RPV level of 200"
_____ B.           unreliable                 at an indicated RPV level of 220
 
_____ C.           unreliable                 at an indicated RPV level of 240
_____ B. unreliable   at an indicated RPV level of 220"
_____ D.           unreliable                 at an indicated RPV level of 280 Correct Answer : C Reference Leg heating due to Drywell High Temperature causes B21-N027 to indicate HIGHER than actual RPV Water Level. EOP Procedures restrict instrument use to ONLY RPV Levels above the Minimum Indicated Level. The Saturation Curve must be used to determine if in unreliable region. 240 and 280 inches are above the minimum but 240 is the lowest.
 
Plausible Distractors:
_____ C.     unreliable   at an indicated RPV level of 240"
 
_____ D. unreliable   at an indicated RPV level of 280"
 
Correct Answer : C Reference Leg heating due to Drywell Hi gh Temperature causes B21-N027 to indicate HIGHER than actual RPV Water Level. EOP Procedures restrict instrument use to ONLY RPV Levels above the Minimum Indicated Level.
The Saturation Curve must be used to determine if in unreliable region. 240 and 280 inches are above the minimum but 240 is the lowest. Plausible Distractors:  
 
Distractors are plausible, if candidate does not use EOP curves and tables correctly.
Distractors are plausible, if candidate does not use EOP curves and tables correctly.
Objective Link: ST-OP-802-3002-01-05  
Objective Link: ST-OP-802-3002-01-05


2006 Fermi-2 NRC RO License Exam - Retake RO 69 Tier 2 K/A Number 226001 Statement K4.10 IR 2.9 Origin B Source Question  Fermi-2 2003 NRC Exam LOK H (3PEO) Grp 2 10 CFR 55.41(b) 7 LOD (1-5) 3.1 Reference Documents ST-OP-315-0041, Rev 14 QUESTION 70  
2006 Fermi-2 NRC RO License Exam - Retake RO     Tier         K/A Number           Statement    IR    Origin  Source Question 69      2              226001               K4.10     2.9       B     Fermi-2 2003 NRC Exam LOK     Grp       10 CFR 55.41(b) 7       LOD (1-5)   Reference Documents H      2                                    3.1     ST-OP-315-0041, Rev 14 (3PEO)
 
QUESTION 70 A LOCA has occurred. The following conditions exist:
A LOCA has occurred. The following conditions exist:
* Reactor Pressure is 200 psig, stable.
* Reactor Pressure is 200 psig, stable.
* Reactor Water Level is 30 inches, stable.
* Reactor Water Level is 30 inches, stable.
Line 1,598: Line 1,187:
* Containment Spray Mode Select switch is in MANUAL.
* Containment Spray Mode Select switch is in MANUAL.
* Containment Spray 2/3 Core Height Override keylock switch is in NORMAL.
* Containment Spray 2/3 Core Height Override keylock switch is in NORMAL.
A subsequent loss of 345 Kv Offsite Power and failure of EDGs 13 and 14 result in Reactor Water Level falling to -50 (minus 50) inches on the Core Level Instruments. What is the expected RHR system response?  
A subsequent loss of 345 Kv Offsite Power and failure of EDGs 13 and 14 result in Reactor Water Level falling to -50 (minus 50) inches on the Core Level Instruments. What is the expected RHR system response?
 
_____ A. Division 1 Containment Spray and Cooling valves will close. Division 1 RHR discharge pressure will increase and Division 1 RHR will inject to the vessel through Division 1.
_____ A. Division 1 Containment Spray and Cooling valves will close. Division 1 RHR   discharge pressure will increase and Division 1 RHR will inject to the vessel   through Division 1.
_____ B. Division 1 Containment Spray and Cooling valves will close. Division 1 RHR discharge pressure will increase and Division 1 RHR will inject to the vessel through Division 2.
_____ B. Division 1 Containment Spray and Cooling valves will close. Division 1 RHR   discharge pressure will increase and Division 1 RHR will inject to the vessel   through Division 2.
_____ C. Division 1 Containment Spray and Cooling valves will remain open. Division 1 RHR discharge pressure will decrease and Division 1 RHR will inject to the vessel through Division 1.
_____ C. Division 1 Containment Spray and Cooling valves will remain open. Division 1   RHR discharge pressure will decrease and Division 1 RHR will inject to the vessel   through Division 1.
_____ D. Division 1 Containment Spray and Cooling valves will remain open. Division 1 RHR discharge pressure will decrease and Division 1 RHR will inject to the vessel through Division 2.
_____ D. Division 1 Containment Spray and Cooling valves will remain open. Division 1   RHR discharge pressure will decrease and Division 1 RHR will inject to the vessel   through Division 2.
 
2006 Fermi-2 NRC RO License Exam - Retake Correct Answer :  B 2/3 Core Height (Level 0 = -42 inches) Isolates Containment Cooling, ONLY Division 2 valves are affected by subsequent LOOP since Division 2 EDGs failed to start. LPCI remains selected to the B Loop.
Plausible Distractors:   


2006 Fermi-2 NRC RO License Exam - Retake Correct Answer : B 2/3 Core Height (Level 0 = -42 inches) Isolates Containment Cooling, ONLY Division 2 valves are affected by subsequent LOOP since Division 2 EDGs failed to start. LPCI remains selected to the B Loop.
Plausible Distractors:
Distractors are plausible, identifying power supply misconceptions and the effect on the remaining RHR Pumps and LPCI flowpath.
Distractors are plausible, identifying power supply misconceptions and the effect on the remaining RHR Pumps and LPCI flowpath.
Objective Link: ST-OP-315-0041-A016  
Objective Link: ST-OP-315-0041-A016
 
2006 Fermi-2 NRC RO License Exam - Retake RO 71 Tier 2 K/A Number 241000 Statement K6.08 IR 3.6 Origin N Source Question N/A LOK H (3PEO) Grp 2 10 CFR 55.41(b) 7 LOD (1-5) 3.2 Reference Documents:
ST-OP-315-0045, Rev 12 QUESTION 71


The following conditions exist:
2006 Fermi-2 NRC RO License Exam - Retake RO      Tier        K/A Number            Statement      IR    Origin  Source Question 71        2            241000              K6.08        3.6    N      N/A LOK      Grp      10 CFR 55.41(b) 7        LOD (1-5)    Reference Documents:
H        2                                  3.2        ST-OP-315-0045, Rev 12 (3PEO)
QUESTION 71 The following conditions exist:
* Reactor power is 65%.
* Reactor power is 65%.
* RPV Pressure is 1010 psig.
* RPV Pressure is 1010 psig.
Line 1,620: Line 1,206:
* Reactor Flow Limiter setting is 115%.
* Reactor Flow Limiter setting is 115%.
* Pressure Regulator No. 1 is in service set at 944 psig.
* Pressure Regulator No. 1 is in service set at 944 psig.
A transient occurs that results in a reactor power increase to 85% CTP. This causes:  
A transient occurs that results in a reactor power increase to 85% CTP. This causes:
 
_____ A.       Turbine Control Valves to CLOSE and will result in an RPS actuation from TCV Fast Closure.
_____ A. Turbine Control Valves to CLOSE and will result in an RPS actuation from TCV Fast Closure.  
_____ B.       Turbine Control Valves to OPEN and will result in an RPS actuation associated with RPV Level.
 
_____ C.       Turbine Control Valves AND Bypass Valves to OPEN. NO RPS actuations are expected to occur.
_____ B. Turbine Control Valves to OPEN and will result in an RPS actuation associated with RPV Level.  
_____ D.       Turbine Control Valves to AND Bypass Valves to OPEN. This transient will be terminated by RPS actuation associated with RPV Pressure.
 
Correct Answer : C An increase in reactor power causes TCVs to open. The BPVs will open on pressure control once power rises to 70% based on Turbine Flow Limiter setting. Steam flow will not exceed the BPV capacity (25%) and reactor pressure and power will rise. No RPS actuations will occur.
_____ C. Turbine Control Valves AND Bypass Valves to OPEN. NO RPS actuations are expected to occur.  
Plausible Distractors:
 
A is plausible, if misconception about Pressure Control mode exists. This is plausible if TCVs initially CLOSE due to a Trip signal.
_____ D. Turbine Control Valves to AND Bypass Valves to OPEN. This transient will be terminated by RPS actuation associated with RPV Pressure.  
B is plausible, if misconception about plant effects exist. High steam flow could cause


Correct Answer :  C An increase in reactor power causes TCVs to open. The BPVs will open on pressure control once power rises to 70% based on Turbine Flow Limiter setting. Steam flow will not exceed the BPV capacity (25%) and reactor pressure and power will rise. No RPS actuations will occur. Plausible Distractors:
2006 Fermi-2 NRC RO License Exam - Retake lowering level, if makeup capability is inadequate. The Feedwater system can handle a 20%
A is plausible, if misconception about Pressure Control mode exists. This is plausible if TCVs initially CLOSE due to a Trip signal.
B is plausible, if misconception about plant effects exist. High steam flow could cause 2006 Fermi-2 NRC RO License Exam - Retake lowering level, if makeup capability is inadequate. The Feedwater system can handle a 20%
power change.
power change.
D is plausible, if BPV capacity is exceeded.
D is plausible, if BPV capacity is exceeded.
Objective Link: ST-OP-315-0045-A016  
Objective Link: ST-OP-315-0045-A016
 
2006 Fermi-2 NRC RO License Exam - Retake RO 72  Tier 2 K/A Number 256000 Statement A4.03 IR 3.2 Origin B Source Question  Fermi-2 2001 NRC Exam LOK H (2RI) Grp 2 10 CFR 55.41(b) 7 LOD (1-5) 3.6 Reference Documents 5D131, Rev 9 QUESTION 72 


The following plant conditions exist:
2006 Fermi-2 NRC RO License Exam - Retake RO      Tier        K/A Number          Statement      IR    Origin Source Question 72        2            256000              A4.03        3.2      B  Fermi-2 2001 NRC Exam LOK      Grp      10 CFR 55.41(b) 7      LOD (1-5)      Reference Documents H (2RI)      2                                  3.6      5D131, Rev 9 QUESTION 72 The following plant conditions exist:
* 5D131, SOUTH HOTWELL LEVEL HIGH/LOW, in alarm.
* 5D131, SOUTH HOTWELL LEVEL HIGH/LOW, in alarm.
* N61-R805, South Hotwell Primary/Backup Level Indicator, indicates 49 inches (lowering)  
* N61-R805, South Hotwell Primary/Backup Level Indicator, indicates 49 inches (lowering)
 
Which statement describes the plant status for the given conditions?
Which statement describes the plan t status for the given conditions?  
_____ A.       Condenser Pumps, tripped Heater Feed Pumps, tripped Reactor Feed Pumps, tripped
 
_____ B.       Normal Hotwell Supply Pump auto started.
_____ A. Condenser Pumps, tripped Heater Feed Pumps, tripped Reactor Feed Pumps, tripped
N2000-F620, Condenser Hotwell Relief Station Bypass Valve, closed N20-F407, Condenser Hotwell Normal Makeup LCV, open (> 90% indicated)
 
_____ C.       Normal and Emergency Hotwell Supply Pumps are running.
_____ B. Normal Hotwell Supply Pump auto started. N2000-F620, Condenser Hotwell Relief Station Bypass Valve, closed   N20-F407, Condenser Hotwell Normal Makeup LCV, open (> 90% indicated)  
N20-F406, Condenser Hotwell Emergency Makeup LCV, open (> 20% indicated)
 
N20-F407, Condenser Hotwell Normal Makeup LCV, open (> 90% indicated)
_____ C. Normal and Emergency Hotwell Supply Pumps are running. N20-F406, Condenser Hotwell Emergenc y Makeup LCV, open
_____ D.       N20-F406 Condenser Hotwell Emergency Makeup LCV, closed (0% indicated)
(> 20% indicated)   N20-F407, Condenser Hotwell Normal Makeup LCV, open (> 90% indicated)
N20-F407, Condenser Hotwell Normal Makeup LCV, closed (0% indicated)
_____ D. N20-F406 Condenser Hotwell Emergenc y Makeup LCV, closed (0% indicated)   N20-F407, Condenser Hotwell Normal Makeup LCV, closed (0% indicated)   N2000-F636, Condenser Hotwell Emer gency Makeup Bypass Valve, closed  
N2000-F636, Condenser Hotwell Emergency Makeup Bypass Valve, closed Correct Answer : B At  50 inches Hotwell Level, with the Condenser Hotwell Normal Makeup LCV  90% open, the Normal Hotwell Supply Pump Auto starts.
 
Correct Answer : B At  50 inches Hotwell Level, with the Condenser Hotwell Normal Makeup LCV  90% open, the Normal Hotwell Supply Pump Auto starts.
Plausible Distractors:
Plausible Distractors:
A is plausible on Low Hotwell Level, but no trips have been reached.
A is plausible on Low Hotwell Level, but no trips have been reached.
C is plausible, but Emergency Makeup Level has not been reached, Emergency pump has not started, Emergency Makeup LCV has not opened.
C is plausible, but Emergency Makeup Level has not been reached, Emergency pump has not started, Emergency Makeup LCV has not opened.
2006 Fermi-2 NRC RO License Exam - Retake D is plausible, correct alignment for Normal Hotwell Levels.
2006 Fermi-2 NRC RO License Exam - Retake D is plausible, correct alignment for Normal Hotwell Levels.
Objective Link: ST-OP-315-0006-A015 2006 Fermi-2 NRC RO License Exam - Retake RO 74 Tier 2 K/A Number 271000 Statement K6.08 IR 2.9 Origin N Source Question N/A LOK F (1P) Grp 2 10 CFR 55.41(b) 7 LOD (1-5) 2.75 Reference Documents 6D2, Rev 9 QUESTION 73
Objective Link: ST-OP-315-0006-A015


With the plant operating at 100% power and Hydrogen Water Chemistry (HWC) in service, the following occurs:
2006 Fermi-2 NRC RO License Exam - Retake RO      Tier          K/A Number          Statement      IR    Origin  Source Question 74        2              271000              K6.08        2.9      N    N/A LOK      Grp        10 CFR 55.41(b) 7      LOD (1-5)      Reference Documents F (1P)      2                                    2.75      6D2, Rev 9 QUESTION 73 With the plant operating at 100% power and Hydrogen Water Chemistry (HWC) in service, the following occurs:
* 6D2, SJAE STEAM PRESSURE HIGH / LOW, alarms.
* 6D2, SJAE STEAM PRESSURE HIGH / LOW, alarms.
* N11-R802, Main Steam to OG SJAE & Prehea ters Pressure Indicator, reads 40 psig.
* N11-R802, Main Steam to OG SJAE & Preheaters Pressure Indicator, reads 40 psig.
The effect of the above conditions on the Off Gas System is:  
The effect of the above conditions on the Off Gas System is:
 
_____ A.       LOW Off Gas System Flow.
_____ A.
_____ B.       LOW Off Gas Oxygen Concentration.
LOW Off Gas System Flow.  
_____ C.       HIGH Off Gas Hydrogen Concentration.
 
_____ D.       HIGH Off Gas Radiation Monitor Indication.
_____ B.
Correct Answer : A The SJAEs isolate with steam pressure < 50 psig and condenser vacuum will decrease, per the ARP. With no condenser non-condensables and steam flow through the SJAEs, Off Gas system flow will decrease.
LOW Off Gas Oxygen Concentration.  
Plausible Distractors:
 
B is plausible, with no flow, no Hydrogen is available for recombination, Oxygen concentration rises.
_____ C.
C is plausible, this is an AOP indication for a wet recombiner.
HIGH Off Gas Hydrogen Concentration.
D is plausible, this is an AOP indication for failed fuel cladding. Low System Flow will cause LOW Radiation Monitor Readings. Slower process flow allows as shorter lived nuclides to decay prior to reaching the monitor.
_____ D.
Objective Link: ST-OP-315-0035-B003
HIGH Off Gas Radiation Monitor Indication.  
 
Correct Answer : A The SJAEs isolate with steam pressure < 50 psig and condenser vacuum will decrease, per the ARP. With no condenser non-condensables and steam flow through the SJAEs, Off Gas system flow will decrease.
Plausible Distractors:  
 
B is plausible, with no flow, no Hydroge n is available for recombination, Oxygen concentration rises.
C is plausible, this is an AOP indication for a wet recombiner. D is plausible, this is an AOP indication for failed fuel cladding. Low System Flow will cause LOW Radiation Monitor Readings.
Slower process flow allows as shorter lived nuclides to decay prior to reaching the monitor.
Objective Link: ST-OP-315-0035-B003 2006 Fermi-2 NRC RO License Exam - Retake RO 73 Tier 2 K/A Number 259001 Statement K5.03 IR 2.8 Origin N Source Question N/A LOK F (1P) Grp 2 10 CFR 55.41(b) 10 LOD (1-5) 3.0 Reference Documents 23.107 Rev 106 QUESTION 74
 
According to 23.107, "Reactor Feedwater and Condensate Systems", the Reactor Feed Pump Turbines should be warmed for:
 
_____ A. 1 hour at 1000 rpm ONLY.
_____ B. [[estimated NRC review hours::6 hours]] at 1600-1800 rpm ONLY. _____ C. 1 hour at 1000 rpm AND 1 hour at 1600-1800 rpm.


_____ D. [[estimated NRC review hours::6 hours]] at 1000 rpm AND [[estimated NRC review hours::6 hours]] at 1600-1800 rpm.  
2006 Fermi-2 NRC RO License Exam - Retake RO      Tier          K/A Number        Statement      IR    Origin  Source Question 73        2              259001            K5.03        2.8    N      N/A LOK      Grp      10 CFR 55.41(b) 10      LOD (1-5)    Reference Documents F (1P)      2                                  3.0      23.107 Rev 106 QUESTION 74 According to 23.107, Reactor Feedwater and Condensate Systems, the Reactor Feed Pump Turbines should be warmed for:
 
_____ A.      1 hour at 1000 rpm ONLY.
Correct Answer : C 23.107. Precaution and Limitation 3.1.7 states, "Each RFPT should be warmed for 1 hour at 1000 rpm and 1 hour at 1600-1800 rpm.
_____ B.      [[estimated NRC review hours::6 hours]] at 1600-1800 rpm ONLY.
_____ C.      1 hour at 1000 rpm AND 1 hour at 1600-1800 rpm.
_____ D.       [[estimated NRC review hours::6 hours]] at 1000 rpm AND [[estimated NRC review hours::6 hours]] at 1600-1800 rpm.
Correct Answer : C 23.107. Precaution and Limitation 3.1.7 states, Each RFPT should be warmed for 1 hour at 1000 rpm and 1 hour at 1600-1800 rpm.
Plausible Distractors:
Plausible Distractors:
A is plausible, partial statement of warming requirements.
A is plausible, partial statement of warming requirements.
B and D are plausible because these are the old requirements for the S. RFPT before the drain piping was modified.
B and D are plausible because these are the old requirements for the S. RFPT before the drain piping was modified.
Objective Link: ST-OP-315-0007-B005  
Objective Link: ST-OP-315-0007-B005
 
2006 Fermi-2 NRC RO License Exam - Retake RO 75 Tier 2 K/A Number 290002 Statement K3.03 IR 3.3 Origin N Source Question N/A LOK H  (3 PEO) Grp 2 10 CFR 55.41(b) 7 LOD (1-5) 3.6 Reference Documents 20.138.02 Rev 23 QUESTION 75
 
With the plant operating at 100% power, the following indications are observed:
* B21-R609A, Jet Pump 15 Flow, lowered from 5.0x10 6 to 0 lb/hr.
* B21-R611A, Jet Pumps 11-20 Loop A Flow, lowered from 44x10 6 to 39 x10 6 lb/hr.
* B31-R617, Recirc "A" Loop Flow, increased from 30,000 to 34,000 gpm.
* B21-R613, Reactor Core DP Indicator, lowered from 32 to 22 psid.
 
This will cause Reactor Power to:


_____ A.
2006 Fermi-2 NRC RO License Exam - Retake RO      Tier        K/A Number          Statement    IR    Origin  Source Question 75      2            290002              K3.03      3.3      N      N/A LOK      Grp      10 CFR 55.41(b) 7      LOD (1-5)  Reference Documents H        2                                  3.6    20.138.02 Rev 23 (3 PEO)
RISE AND APRM Simulated Thermal Powe r Upscale Trip Setpoint to RISE. _____ B.
QUESTION 75 With the plant operating at 100% power, the following indications are observed:
RISE AND APRM Simulated Thermal Powe r Upscale Trip Setpoint to LOWER.
* B21-R609A, Jet Pump 15 Flow, lowered from 5.0x106 to 0 lb/hr.
_____ C.
* B21-R611A, Jet Pumps 11-20 Loop A Flow, lowered from 44x106 to 39 x106 lb/hr.
LOWER AND APRM Simulated Thermal Power Upscale Trip Setpoint to RISE.
* B31-R617, Recirc A Loop Flow, increased from 30,000 to 34,000 gpm.
_____ D.
* B21-R613, Reactor Core DP Indicator, lowered from 32 to 22 psid.
LOWER AND APRM Simulated Thermal Power Upscale Trip Setpoint to LOWER.
This will cause Reactor Power to:
Correct Answer : C Indications are given for a Jet Pump separation. Lower Reactor Core DP indicates lower ACTUAL Core Flow which LOWERS Reactor Po wer. Recirc A Loop Flow Increased which raises APRM Simulated Thermal Power Upscale Trip Setpoint.
_____ A.       RISE AND APRM Simulated Thermal Power Upscale Trip Setpoint to RISE.
_____ B.       RISE AND APRM Simulated Thermal Power Upscale Trip Setpoint to LOWER.
_____ C.       LOWER AND APRM Simulated Thermal Power Upscale Trip Setpoint to RISE.
_____ D.       LOWER AND APRM Simulated Thermal Power Upscale Trip Setpoint to LOWER.
Correct Answer : C Indications are given for a Jet Pump separation. Lower Reactor Core DP indicates lower ACTUAL Core Flow which LOWERS Reactor Power. Recirc A Loop Flow Increased which raises APRM Simulated Thermal Power Upscale Trip Setpoint.
Plausible Distractors:
Plausible Distractors:
A is plausible, if misconception about Recirc Loop Flow vs Jet Pump Loop Flow effect on Reactor Power exists. (Recirc Runaway)
A is plausible, if misconception about Recirc Loop Flow vs Jet Pump Loop Flow effect on Reactor Power exists. (Recirc Runaway)
B is plausible, if misconception about Recirc Loop Flow vs Jet Pump Loop Flow effect on Reactor Power exists AND flow instrument input to APRM Flow exists. D is plausible is misconception about flow instrument input to APRM Flow exists.
B is plausible, if misconception about Recirc Loop Flow vs Jet Pump Loop Flow effect on Reactor Power exists AND flow instrument input to APRM Flow exists.
Objective Link: ST-OP-315-0004-C011}}
D is plausible is misconception about flow instrument input to APRM Flow exists.
Objective Link: ST-OP-315-0004-C011}}

Revision as of 15:36, 23 November 2019

As-administered Written Fermi August 2006 RO Retake Examination
ML062420268
Person / Time
Site: Fermi DTE Energy icon.png
Issue date: 08/31/2006
From:
NRC/RGN-III
To:
Detroit Edison
References
50-341/06-302 50-341/06302
Download: ML062420268 (102)


Text

2006 Fermi-2 NRC RO License Exam - Retake RO Tier K/A Number Statement IR Origin Source Question 2 3 Generic 2.1.11 3.0 N N/A LOK 10 CFR 55.41(b) 10 LOD (1-5) Reference Documents F (1F) 2.5 Tech Spec 3.8.1 QUESTION 1 With the plant in MODE 1, Emergency Diesel Generator 13 has been declared INOPERABLE.

Which one of the following Tech Spec Required Actions has a specified Required Completion Time WITHIN ONE HOUR?

_____ A. Verify that CTG 11-1 is AVAILABLE.

_____ B. Verify Offsite Power Sources are OPERABLE.

_____ C. Verify that EDGs 11, 12, and 14 are not also INOPERABLE due to common cause failure.

_____ D. Declare the required features supported by EDG 13 INOPERABLE when the redundant required features are INOPERABLE.

Correct Answer : B 3.8.1 Condition A, Required Action A.1 Perform SR 3.8.1.1. for OPERABLE offsite circuit(s) within 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br />.

Plausible Distractors:

A is plausible, Completion Time is once per 8 hours0.333 days <br />0.0476 weeks <br />0.011 months <br />.

C is plausible, Completion Time is within 4 hours0.167 days <br />0.0238 weeks <br />0.00548 months <br /> of discovery of inoperable EDG concurrent with inoperability of redundant required features.

D is plausible, Completion Time is within 24 hours1 days <br />0.143 weeks <br />0.0329 months <br />.

Objective Link: ST-OP-315-0065-001-C012

2006 Fermi-2 NRC RO License Exam - Retake RO Tier K/A Number Statement IR Origin Source Question 3 3 Generic 2.1.29 3.4 B Fermi-2 2003 NRC Exam LOK 10 CFR 55.41(b) 10 LOD (1-5) Reference Documents F (1P) 2.5 MOP02, Rev 8 QUESTION 2 Performance of a pre-startup valve lineup will involve aligning a valve that is to be LOCKED CLOSED. The valve in question is located in a CONTAMINATED work area.

In this situation, per MOP02, Independent Verification, independent verification of valve position ______________________.

_____ A. is accomplished by visual verification that the locking device is properly installed.

_____ B. is performed by removing the locking device, checking the valve position, and re-installing the locking device.

_____ C. should be performed by hands on checking of the valve position without removing or breaking the locking device.

_____ D. may be waived by the CRS to conserve man-rem rather than require two individuals to enter the contaminated area.

Correct Answer : C Second individual performs a hands on independent verification of the component without removing or breaking the locking device per MOP02.

Plausible Distractors:

A is plausible, it is required to verify locking device installed properly, in addition to verifying valve position. Procedure requires hands on verification.

B is plausible, but not procedural per MOP02.

D is plausible, supervision may waive verification for radiation dose considerations, NOT contamination conditions.

Objective Link: LP-OP-802-4201-0009

2006 Fermi-2 NRC RO License Exam - Retake RO Tier K/A Number Statement IR Origin Source Question 4 3 Generic 2.2.11 2.5 B N/A LOK 10 CFR 55.41(b) 10 LOD (1-5) Reference Documents F (1B) 2.5 MGA04 Rev 14 QUESTION 3 A change to a procedure using the Temporary Change Notice process is appropriate in which of the following situations?

_____ A. To correct an incorrect source reference.

_____ B. To revise surveillance acceptance criteria values.

_____ C. To correct an incorrect component identification.

_____ D. To implement changes to administrative procedures.

Correct Answer : C MGA04, Temporary Change Notices, section 3.3.2 specifically allows use of Temporary Change Notices to correct component identification errors in procedures.

Plausible Distractors:

A is plausible, mentioned in MGA04 section 3.4.5 as a condition where Temporary Change Notice use is NOT allowed.

B is plausible, mentioned in MGA04 section 3.4.2 as a condition where Temporary Change Notice use is NOT allowed.

D is plausible, mentioned in MGA04 section 3.4.1 as a condition where Temporary Change Notice use is NOT allowed.

Objective Link: LP-OP-802-4101-0013

2006 Fermi-2 NRC RO License Exam - Retake RO Tier K/A Number Statement IR Origin Source Question 5 3 Generic 2.2.30 3.5 B Fermi-2 2003 NRC Exam LOK 10 CFR 55.41(b) 10 LOD (1-5) Reference Documents F (1B) 3.0 Technical Specifications Technical Requirements Manual QUESTION 4 Which one of the following statements is a Technical Specification/Technical Requirement Manual requirement when moving fuel during Core Alterations?

_____ A. ALL SRMs SHALL be Operable.

_____ B. The Fuel Preparation Machines MAY NOT be used for storing fuel.

_____ C. The Refueling Platform Main Hoist is the ONLY lifting device permitted to transport fuel.

_____ D. Direct communications SHALL be maintained between the Refueling Platform and the Control Room.

Correct Answer : D Direct communications shall be maintained between the Refueling Platform and the Control Room is required by the Technical Requirements Manual.

Plausible Distractors:

A is plausible, during REFUEL, Tech Specs require only two SRMs Operable.

B is plausible, there is no TS or TRM prohibition for the use of the Fuel Preparation Machine.

C is plausible, there is no TS or TRM restriction requiring use of ONLY the Refueling Platform Main Hoist.

Objective Link: LP-OP-802-4101-0030

2006 Fermi-2 NRC RO License Exam - Retake RO Tier K/A Number Statement IR Origin Source Question 8 3 Generic 2.3.2 2.5 B Fermi-2 2003 NRC Exam LOK 10 CFR 55.41(b) 12 LOD (1-5) Reference Documents F (1F) 2.3 MRP10 Rev 3 QUESTION 5 Which one of the following describes the embryo/fetus Federal Dose Limits and the Fermi - 2 Administrative Dose Guidelines for radiation workers?

_____ A. 100 mrem spread over the term of the pregnancy.

_____ B. 500 mrem spread over the term of the pregnancy.

_____ C. 750 mrem spread over the term of the pregnancy.

_____ D. 1000 mrem spread over the term of the pregnancy.

Correct Answer : B Stated in MRP10, Fetal Protection Program.

Plausible Distractors:

A is plausible, 100 mrem/year limit for non-radworkers.

C is plausible, if 500 mrem limit is not known.

D is plausible, Fermi annual limit for radworkers.

Objective Link: LP-GN-508-0001-A017

2006 Fermi-2 NRC RO License Exam - Retake RO Tier K/A Number Statement IR Origin Source Question 9 3 Generic 2.4.11 3.4 N N/A LOK 10 CFR 55.41(b) 10 LOD (1-5) Reference Documents H 2.7 20.106.01 Rev 17 (3PEO/2RI)

QUESTION 6 The plant is operating at 100% power when the following occurs:

  • 3D96, MOTOR TRIPPED, alarms.
  • 3D5, CRD CHARGING H2O PRESSURE LOW, alarms.
  • C1106-C001A, East CRD Pump, White CMC Switch indicating light is LIT.

With these conditions, the procedurally required action is to:

_____ A. Place the Reactor Mode Switch in SHUTDOWN IMMEDIATELY.

_____ B. Place the Reactor Mode Switch in SHUTDOWN WITHIN 20 MINUTES.

_____ C. Close the C1100-F034, CRD Charging Water Isolation Valve, and then start C1106-C001B, West CRD Pump.

_____ D. Place the CRD Flow Controller in MANUAL, close the CRD Flow Control Valve and Pressure Control Valve and then start C1106-C001B, West CRD Pump.

Correct Answer : D Correct actions for a CRD Pump Failure per 20.106.01, CRD HYDRAULIC SYSTEM FAILURE.

Plausible Distractors:

A is plausible, correct if <900 psig.

B is plausible, correct if MORE THAN ONE Accumulator Fault occurs.

C is plausible, correct if Standby CRD Pump fails to start when attempted.

Objective Link: SS-OP-802-2001

2006 Fermi-2 NRC RO License Exam - Retake RO Tier K/A Number Statement IR Origin Source Question 10 3 Generic 2.4.20 3.3 N N/A LOK 10 CFR 55.41(b) 10 LOD (1-5) Reference Documents H (2RI) 3.5 29.100.01 Sheet 1, RPV Control QUESTION 7 Following a LOCA, the following conditions exist:

  • ONLY Division 1 RHR Pumps are running.
  • ALL other ECCS systems have failed.
  • Reactor Pressure is 500 psig.
  • Emergency Depressurization has NOT occurred.

Per the EOPs, the LOWEST stable RPV Water Level which assures Adequate Core Cooling under these conditions is ______ .

_____ A. 0 (zero) inches

_____ B. -20 (minus 20) inches

_____ C. -30 (minus 30) inches

_____ D. -45 (minus 45) inches Correct Answer : B 29.100.01 Sheet 1 specifies maintaining injection at stable RPV Water Levels > -25 (minus 25) inches. -20 (minus 20) inches is the LOWEST stable RPV Water Level listed which assures adequate core cooling. Candidate must identify Adequate Core Cooling as operational implication of EOP notes.

Plausible Distractors:

A is plausible, but not the lowest, Core Submergence is adequate under all conditions, but adequate core cooling is assured at LOWER levels with injection.

C is plausible, and is correct prior to Emergency Depressurization WITHOUT Injection (Steam Cooling).

D is plausible, and is correct FOLLOWING Emergency Depressurization WITH one full loop of Core Spray injecting.

Objective Link: ST-OP-802-3001-001-008

2006 Fermi-2 NRC RO License Exam - Retake RO Tier K/A Number Statement IR Origin Source Question 13 1 295004 AA1.02 3.8 N N/A LOK Grp 10 CFR 55.41(b) 10 LOD (1-5) Reference Documents H (2RI) 1 3.5 20.300.260VESF, Rev 1 QUESTION 8 The plant is operating at 100% power with RHR Pump A operating in Torus Cooling.

A transient occurs, resulting in the following conditions:

  • RCIC is injecting at 650 gpm.
  • 9D17, DIV I ESS 130V BATTERY TROUBLE, alarms.
  • 1D6, DIV I CSS LOGIC POWER FAILURE, alarms.
  • 1D8, RHR LOGIC A 125V DC BUS POWER FAILURE, alarms.
  • ALL Division 1 ECCS Pump CMC switches lose indication (no lights).

With the above conditions, which one of the following correctly completes the statement?

RHR Pump A is ___________.

_____ A. RUNNING, and CAN be electrically tripped

_____ B. RUNNING, and CANNOT be electrically tripped

_____ C. TRIPPED, and WILL auto start on receipt of a valid signal

_____ D. TRIPPED, and WILL NOT auto start on receipt of a valid signal Correct Answer : B RHR Pump A has lost control power, indicated by the DC Annunciators. RHR Pump A will continue to run and cannot be electrically tripped.

Plausible Distractors:

A is plausible, RHR pump loses control power and will remain running, but cannot be electrically tripped.

C is plausible, RHR pump loses control power, which is required for BOTH trip and start functions.

2006 Fermi-2 NRC RO License Exam - Retake D is plausible, RHR pump loses control power, which is required for BOTH trip and start functions.

Objective Link: ST-OP-315-0045-B008 B007 B000

2006 Fermi-2 NRC RO License Exam - Retake RO Tier K/A Number Statement IR Origin Source Question 11 1 295001 AK2.01 3.6 N N/A LOK Grp 10 CFR 55.41(b) 10 LOD(1-5) Reference Documents H (2RI) 1 2.25 20.138.01 Rev 40 QUESTION 9 The plant is operating in SINGLE LOOP, Reactor Power is 55%, and RRMG Set A speed is 60%, when the following alarms are received:

  • 3D104, RECIRC PMP A MG DRIVE MTR GRD FAULT / OVERCURRENT
  • 3D96, MOTOR TRIPPED With these conditions, which one of the following actions is required?

_____ A. Monitor for neutron flux instabilities.

_____ B. Place the Reactor Mode Switch in SHUTDOWN.

_____ C. Insert control rods in sequence to restore operation outside the EXIT region of the Power to Flow Map.

_____ D. Restart Reactor Recirculation Pump B and raise flow to restore operation outside the EXIT region of the Power to Flow Map.

Correct Answer : B Correct actions for loss of BOTH Recirculation Loops.

Plausible Distractors:

A is plausible, correct follow up action for loss of ONE Loop with TWO Loops initially operating.

C is plausible, also performed for loss of ONE Loop with TWO Loops initially operating.

D is plausible, higher core flow will restore operation outside the EXIT region, but pump restarts are prohibited.

Objective Link: SS-OP-802-2001-RO-0002

2006 Fermi-2 NRC RO License Exam - Retake RO Tier K/A Number Statement IR Origin Source Question 14 1 295005 AA2.06 2.6 B N/A LOK Grp 10 CFR 55.41(b) 5 LOD (1-5) Reference Documents H (2RI/ 1 3.1 3D91, Rev 9, TS Table 3.3.1.1 3PEO) ST-OP-315-0045-001, Rev12 QUESTION 10 The plant is at 18% power when the turbine trips. The reactor will ______________.

_____ A. remain operating AND reactor power will remain CONSTANT

_____ B. SCRAM AND reactor pressure will INCREASE due to decay heat

_____ C. SCRAM AND reactor pressure will DECREASE due to BPV operation

_____ D. remain operating AND reactor power will INCREASE due to Feedwater Temperature change Correct Answer : D Justification: Candidate must know that Turbine Trip / Reactor Scram function is bypassed about 30% power. Candidate must know effect of Turbine Trip induced Feedwater Temperature change on Reactor Power. Turbine Trip / Reactor Scram is bypassed below 161.9 psig 1st Stage Turbine Pressure (30% power). Reactor will remain operating on Turbine Bypass Valves. Resulting Feedwater Temperature drop will cause Reactor Power Increase.

Plausible Distractors If candidate does not know that Turbine Trip / Reactor Scram function is bypassed below 30%

power, Scram is plausible. Feedwater Temperature will lower and cause reactor pressure to lower. Post scram pressure changes are plausible due to BPV operation and decay heat values.

Objective Link: LP-OP-315-0145-A018

2006 Fermi-2 NRC RO License Exam - Retake RO Tier K/A Number Statement IR Origin Source Question 6 3 Generic 2.2.22 3.4 B Fermi-2 2001 NRC Exam LOK 10 CFR 55.41(b) 5 LOD (1-5) Reference Documents F (1P) 3.2 Technical Specifications 3.4.4 QUESTION 11 From the given statements select the one that correctly describes the operational leakage allowed from the reactor coolant system in MODE 1.

Reactor Coolant System operational LEAKAGE shall be limited to:

_____ A. 5 gpm TOTAL LEAKAGE.

_____ B. 2 gpm Pressure Boundary LEAKAGE.

_____ C. 25 gpm TOTAL LEAKAGE averaged over the previous 24 hours1 days <br />0.143 weeks <br />0.0329 months <br /> and 5 gpm increase in unidentified LEAKAGE in the previous 12 hour1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> period.

_____ D. 25 gpm TOTAL LEAKAGE averaged over the previous 24 hours1 days <br />0.143 weeks <br />0.0329 months <br /> and 2 gpm increase in unidentified LEAKAGE in the previous 24 hour2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> period.

Correct Answer : D 25 gpm TOTAL LEAKAGE averaged over the previous 24 hours1 days <br />0.143 weeks <br />0.0329 months <br /> and 2 gpm increase in unidentified LEAKAGE in the previous 24 hour2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> period. Per LCO 3.4.4, RCS Operational Leakage.

Plausible Distractors:

A is plausible, 5 gpm is the UNIDENTIFIED Leakage Limit.

B is plausible, NO pressure boundary leakage is permitted.

C is plausible, if UNIDENTIFIED Leakage Limit is confused with INCREASE Limit.

Objective Link: QC-OP-725-0100-0101

2006 Fermi-2 NRC RO License Exam - Retake RO Tier K/A Number Statement IR Origin Source Question 15 1 295006 2.4.4 4 N N/A LOK Grp 10 CFR 55.41(b) 10 LOD (1-5) Reference Documents H (2RI) 1 2.8 20.125.01, Rev 22 20.125.01 Bases, Rev 0 QUESTION 12 The plant is operating at 100% power when the following occur:

  • Generator Megawatts indicates 1030 Mwe (lowering).
  • 4D108, CONDENSER PRESSURE HIGH, alarms.
  • 6D16, OFF GAS SYS MN CONDENSER PRESSURE HIGH, alarms.

How should the operator respond to these conditions?

_____ A. START a Mechanical Vacuum Pump.

_____ B. SWAP operating Steam Jet Air Ejectors.

_____ C. PLACE the Reactor Mode Switch in SHUTDOWN.

_____ D. PERFORM a Rapid Power Reduction per 23.623. Reactor Manual Control System.

Correct Answer : C 20.125.01, Loss of Condenser Vacuum, Override directs the Mode Switch be placed in SHUTDOWN when condenser vacuum is 2.5 psia.

Plausible Distractors:

A is plausible, this is permitted ONLY < 5% Reactor Power.

B is plausible, ADDITIONAL SJAEs may be started, SWAPPING is not procedurally permitted.

D is plausible, 20.125.01 Subsequent Action C states, If condenser vacuum cannot be maintained in the specified band, then a Rapid Power Reduction is required IAW 23.623, Reactor Manual Control System.

Objective Link: SS-OP-802-2001-RO-0001

2006 Fermi-2 NRC RO License Exam - Retake RO Tier K/A Number Statement IR Origin Source Question 16 1 295016 AK2.01 4.4 N N/A LOK Grp 10 CFR 55.41(b) 8 LOD (1-5) Reference Documents F (S) 1 3.6 ST-OP-315-0044-001 QUESTION 13 Which one of the following correctly identifies the RCIC controls or indications available at BOTH the Main Control Room AND the Remote Shutdown Panel?

_____ A. RCIC Pump Flow indication.

_____ B. RCIC Pump Discharge Pressure indication.

_____ C. E5150-F010, RCIC Pump CST Suction Isolation Valve, control pushbuttons.

_____ D. RCIC Pump Flow controller with Manual and Automatic Setpoint Adjustments.

Correct Answer : A RCIC Pump Flow indication exists at both locations.

Plausible Distractors: ALL listed indications and controls exist in the Main Control Room.

B is plausible, E51-R609, RCIC Pump Discharge Pressure exists ONLY in the Main Control Room.

C is plausible, E5150-F010, RCIC Pump CST Suction Isolation Valve control exists ONLY in the Main Control Room.

D is plausible, E51-K615, RCIC Pump Flow Controller with Manual and Automatic setpoint adjustments exists ONLY in the Main Control Room.

Objective Link: ST-OP-315-0044-A013

2006 Fermi-2 NRC RO License Exam - Retake RO Tier K/A Number Statement IR Origin Source Question 17 1 295018 AK1.01 3.5 N N/A LOK Grp 10 CFR 55.41(b) 10 LOD (1-5) Reference Documents H (2RI/ 1 3.0 20.127.01, Rev 27 3PEO)

QUESTION 14 The plant is operating at 100% power with the following conditions:

  • RBCCW Heat Exchangers are experiencing fouling.
  • 2D120, RBCCW HX DISCH TEMPERATURE HIGH/LOW, alarms.
  • RBCCW Heat Exchanger Outlet Temperature is 95 °F (rising).
  • RBCCW Cooling CANNOT be restored.

If this trend continues, which one of the following will AUTOMATICALLY occur?

_____ A. Reactor Water Cleanup Pumps will TRIP on Low Flow.

_____ B. Fuel Pool Cooling and Cleanup Pump will TRIP on Low Flow.

_____ C. Reactor Recirculation Pumps will TRIP on High Motor Winding Temperature.

_____ D. High Pressure Coolant Injection System will ISOLATE on High Area Temperature.

Correct Answer : A Justification: When NRHX High Inlet Temperature is > 140°F, G3352-F119, RWCU Supply Suction Isolation Valve automatically closes. This will cause the operating RWCU Pump to TRIP on Low Flow (< 70 gpm).

Plausible Distractors:

B is plausible, FPCCU is an RBCCW Load, but FPCCU Pumps have no Low Flow Trip.

C is plausible, RR Pumps are RBCCW Loads, but have no High Motor Winding Temperature Trip. There is a High Recirc Motor Generator Air Temperature Trip.

D is plausible, T4100-B022, HPCI Pump Room Cooler receives cooling from RBCCW, but is supplemented by EECW following a complete loss of RBCCW. No steam leak indications, for HPCI, are given in the stem and HPCI is not running to add heat to the room.

Objective Link: ST-OP-315-0067-B004

2006 Fermi-2 NRC RO License Exam - Retake RO Tier K/A Number Statement IR Origin Source Question 18 1 295019 AK3.01 3.3 B N/A LOK Grp 10 CFR 55.41(b) 5 LOD (1-5) Reference Documents H 1 3.25 20.129.01, Rev 25; 23.129, Rev 75 (3SPK)

QUESTION 15 A loss of offsite power has occurred. Power has been restored to ALL Division 1 Buses.

  • The West Station Air Compressor is operating.
  • Division 1 Control Air Compressor is running, system pressure is 100 psig.
  • Division 2 Control Air Compressor failed to start.
  • Division 2 NIAS Header Pressure is 50 psig and steady.

Per 20.129.01, Loss of Station and/or Control Air, what action is necessary to ensure the Div 2 Non-Interruptible Air System supply is available for continued use?

_____ A. Cross-tie NIAS with Division 1 supplying.

_____ B. DEPRESS the OPEN pushbutton for P5000-F403, IAS to Div 2 NIAS Isolation Valve.

_____ C. Place the P5000-F403, IAS to Div 2 NIAS Isolation Valve, keylock switch in OVRD, valve will re-open.

_____ D. OPEN P5000- F440, Div 1 Control Air Isolation Valve, AND P5000- F441, Div 2 Control Air Isolation Valve.

Correct Answer : A Justification: Cross-tie divisions will restore air pressure to Div 2 NIAS.

Plausible Distractors :

Associated with other actions listed in 20.129.01, Loss of Station and/or Control Air. Place the keylock control switch on Panel H11-P807 for P5000-F403, IAS to Div 2 NIAS Iso Vlv to OVRD. overrides closure on LOOP or LOCA. P5000-F403 opens or stays open only when Control air pressure is above 80 psig. The valve lineup in D will cross tie NIAS but is not in accordance with plant procedure. Crosstie occurs down stream of Receiver check valves.

2006 Fermi-2 NRC RO License Exam - Retake Objective Link: LP-OP-315-0171-C001

2006 Fermi-2 NRC RO License Exam - Retake RO Tier K/A Number Statement IR Origin Source Question 19 1 295021 AA1.05 3.0 M EQ-OP-802-2001-000-0001-002 LOK Grp 10 CFR 55.41(b) 10 LOD (1-5) Reference Documents F (1P) 1 2.9 20.205.01, Rev. 18 QUESTION 16 The plant has been recently shutdown for a Refueling Outage, with the following conditions:

  • The Plant is in MODE 4.
  • Decay Heat temperature input is equivalent to a Heat Up Rate (HUR) of 2ºF/min.
  • Div 2 RHR has been isolated, per a Safety Tagging Record (STR), and is draining.
  • Reactor Water Level is 230 inches.
  • Reactor Pressure is 0 psig.

RHR Pump C trips due to a closure of E1150-F008, RHR SDC Otbd Suction Isol Valve, and the valve cannot be re-opened electrically or manually.

Which of the following actions is required under these conditions?

_____ A. Start ONE Core Spray Pump.

_____ B. Start ONE Reactor Recirculation Pump.

_____ C. Start BOTH Control Rod Drive Hydraulic Pumps.

_____ D. Shift Fuel Pool Cooling and Cleanup to the Reactor Well.

Correct Answer : B 20.205.01 Condition H requires starting a Reactor Recirculation Pump when SDC cannot be restored in either loop.

Plausible Distractors:

A is plausible, a Core Spray Pump is used to raise Water Level in preparation for Refuel Operations, with SDC in service and is also used as an Alternate Decay Heat Removal System (Both pumps).

2006 Fermi-2 NRC RO License Exam - Retake C is plausible, will raise RPV Water Level for natural circulation, but does not procedurally mitigate Loss of SDC.

D is plausible, if the Reactor Head were removed (MODE 5), this would be the correct action.

Objective Link: ST-OP-315-0041-C012 Source Question showing MODIFICATIONS The plant is in Mode 4. The following conditions exist: - MODIFIED Division 1 RHR.Shutdown Cooling (SDC)

Division 2 RHR.NOT available. - MODIFIED Reactor Pressure Vessel (RPV) level230 inches RPV pressure.0 psig Division 1 RHR tripped and can NOT be restarted. - MODIFIED What action will the Reactor Operator be directed to perform? - MODIFIED A Start Reactor Recirculation pumps B Raise RPV pressure - MODIFIED C Lower RPV level - MODIFIED D Shift Fuel Pool Cleaning to the Reactor Well

2006 Fermi-2 NRC RO License Exam - Retake RO Tier K/A Number Statement IR Origin Source Question 20 1 295023 AA2.01 3.6 B Clinton 1/15/2004 NRC Exam LOK Grp 10 CFR 55.41(b) 7 LOD (1-5) Reference Documents F (1I) 1 2.7 3D35, Rev 13 QUESTION 17 A Refueling Accident in the Reactor Cavity resulted in the following conditions:

  • 3D31, DIV 1 / 2 FP VENT EXH RADN MONITOR UPSCALE, alarms.
  • 3D35, DIV 1 / 2 FP VENT EXH RADN MONITOR UPSCALE TRIP, alarms.
  • 17D14, DIV 1 / 2 SGTS AUTO START, alarms.

For the given conditions, Reactor Building HVAC Isolation Dampers (1) and the Reactor Building HVAC Supply and Exhaust Fans (2) .

(1) (2)

_____ A. ISOLATE TRIP

_____ B. ISOLATE CONTINUE TO OPERATE

_____ C. REMAIN OPEN TRIP

_____ D. REMAIN OPEN CONTINUE TO OPERATE Correct Answer : A A is correct, RBHVAC Dampers ISOLATE, RB HVAC fans TRIP, and the respective division of SGTS AUTO STARTS, when a FP Vent Exhaust Rad Monitor Upscale Trip occurs.

Plausible Distractors:

B is incorrect, fans TRIP.

C is incorrect, RBHVAC/Secondary Containment Dampers ISOLATE. Dampers remaining open is plausible if SGTS operation misconception of common flowpath.

D is incorrect, fans TRIP, RBHVAC/secondary Containment Dampers ISOLATE. Dampers remaining open is plausible if SGTS operation misconception of common flowpath.

Objective Link: ST-OP-315-0066-A017

2006 Fermi-2 NRC RO License Exam - Retake RO Tier K/A Number Statement IR Origin Source Question 70 2 239001 A3.01 4.2 M Fermi-2 2006 NRC Exam LOK Grp 10 CFR 55.41(b) 7 LOD (1-5) Reference Documents H 2 3.4 20.109.02 Bases, Rev 0 (3PEO)

QUESTION 18 The plant is operating at 85% power, when the IN SERVICE Pressure Regulator fails HIGH.

With NO Operator Actions, which of the following correctly describes the effect of this failure?

_____ A. ONLY an automatic Reactor Scram occurs.

_____ B. A Reactor Scram AND a Group 1 Isolation occurs.

_____ C. Pressure Control swaps to the BACKUP Pressure Regulator AND Reactor Pressure RISES by 3 psig.

_____ D. Pressure Control swaps to the BACKUP Pressure Regulator AND Reactor Pressure LOWERS by 3 psig.

Correct Answer : B 52 Manifold Pressure Transmitter failure HIGH causes the Pressure Regulator to OPEN Turbine Control Valves. This LOWERS Main Steam Line Pressure, at 756 psig, a Group 1 Isolation occurs due to Low Main Steam Line Pressure, which causes a Reactor Scram.

Plausible Distractors:

A is plausible, if Group 1 Isolation is not known, Rapid RPV Pressure reduction may cause SWELL, which causes a Level 8 Turbine Trip and a Reactor Scram ONLY.

C is plausible, this resembles a Pressure Regulator Failure / Automatic Transfer.

D is plausible, this resembles a Pressure Regulator Failure / Automatic Transfer.

Objective Link: ST-OP-315-0045-A016 Source Question:

The plant is operating at 85% power, when the IN SERVICE 52 inch Manifold Pressure Transmitter Output Signal fails HIGH.

2006 Fermi-2 NRC RO License Exam - Retake Based on this failure, what action(s) will the operator perform and why? (MODIFICATION)

A. Perform rapid power reduction to reduce power and pressure.

(MODIFICATION)

B. Ensure backup pressure regulator takes control to maintain pressure.

(MODIFICATION)

C. Transfer to backup pressure transmitter to prevent excessive cooldown (MODIFICATION)

D. Place the Mode Switch in SHUTDOWN and trip the main turbine bypass valves to prevent excessive cooldown.

(MODIFICATION)

2006 Fermi-2 NRC RO License Exam - Retake RO Tier K/A Number Statement IR Origin Source Question 12 1 295003 AK3.05 3.7 N N/A LOK Grp 10 CFR 55.41(b)10 LOD (1-5) Reference Documents H (2RI) 1 2.5 4D132, Rev 7, 20.300.Offsite, Rev 6 QUESTION 19 PRA sensitive issue - 8/2003 Loss of Grid Event The plant is operating at 90% power when the following occurs:

  • 345kV and 120kV mat voltages begin lowering.
  • 4D132, GENERATOR FREQUENCY HIGH / LOW, alarms.
  • Generator Frequency is 59.4 Hz (lowering).
  • 120 kV BUS 101 POWER ON light is OFF.
  • 120 kV BUS 102 POWER ON light is OFF.
  • R14-R819, SS Xfmr # 64 Secondary Volt Indicator, reads zero volts.
  • 345 kV BUS 301 POWER ON light is OFF.
  • 345 kV BUS 302 POWER ON light is OFF.
  • R14-R833, SS Xfmr # 65 Secondary Volt Indicator, reads zero volts.
  • R14-R835, SS Xfmr # 65 Secondary Volt Indicator, reads zero volts.

With these conditions, which one of the following actions is required?

_____ A. Place the Reactor Mode Switch in SHUTDOWN due to a COMPLETE loss of Offsite Power.

_____ B. Manually start and load ALL Emergency Diesel Generators due to loss of Offsite Power to BOTH divisions of ESF Buses.

_____ C. Place the Reactor Mode Switch in SHUTDOWN due to loss of Offsite Power to ONLY ONE division of ESF Buses AND half of the BOP Buses.

_____ D. Verify automatic start and loading of Emergency Diesel Generators 11 AND 12 due to loss of Offsite Power source to ONLY ONE division of ESF Buses.

Correct Answer : A Stem conditions indicate complete Loss of Offsite Power, 20.300.Offsite Immediate Action requires placing Reactor Mode Switch in SHUTDOWN.

2006 Fermi-2 NRC RO License Exam - Retake Plausible Distractors:

B is plausible, it is required to verify automatic EDG starts. It is not appropriate to manually start EDGs.

C is plausible, if power was lost to only the 345kV system, ONE Division of ESF Buses and Half of the BOP Buses would be lost. Mode switch to shutdown is required.

D is plausible, if power were lost to only the 120 kV system, ONE Division of ESF Buses would be affected.

Objective Link: SS-OP-802-2001-RO-0002

2006 Fermi-2 NRC RO License Exam - Retake RO Tier K/A Number Statement IR Origin Source Question 21 1 295024 2.2.22 3.4 N N/A LOK Grp 10 CFR 55.41(b) 9 LOD (1-5) Reference Documents H 1 3.75 Technical Specification 3.6.1.4 (2DS) 29.100.01 Sheet 2, Rev 9, Primary Containment Control.

QUESTION 20 In Mode 1, the UPPER LIMIT for the DRYWELL PRESSURE LCO is (1) the value which requires entry into Emergency Operating Procedures (EOPs).

The Required Action Completion Time to restore Drywell Pressure within limits is (2) .

(1) (2)

_____ A. BELOW IMMEDIATELY

_____ B. BELOW within 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br />

_____ C. ABOVE IMMEDIATELY

_____ D. ABOVE within 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> Correct Answer : D ABOVE is correct LCO is 2.0 psig, EOP Entry is 1.68 psig Within 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> is the correct Completion Time for 3.6.1.4 Plausible Distractors:

A is plausible, if either EOP Entry Condition or LCO is not known. IMMEDIATELY is plausible.

B is plausible, if either EOP Entry Condition or LCO is not known.

C is plausible, Required Action Completion Time is unknown, IMMEDIATELY is plausible.

Objective Link: LP-OP-804-0002

2006 Fermi-2 NRC RO License Exam - Retake RO Tier K/A Number Statement IR Origin Source Question 22 1 295025 EK1.06 3.5 N N/A LOK Grp 10 CFR 55.41(b) 10 LOD (1-5) Reference Documents H 1 3.1 23.201 Rev. 24 (3PEO)

QUESTION 21 Following a Reactor Scram, the following conditions exist:

  • BOTH Bypass Valves have failed closed.
  • RPV Water Level is being maintained by the North Reactor Feed Pump.
  • The Drywell is being vented to lower Drywell Pressure.

Under these conditions, Reactor Water Level should be maintained___________________.

_____ A. at 173 to avoid a Reactor Feed Pump Trip

_____ B. at 197 to avoid a Reactor Feed Pump Trip

_____ C. at 197 to avoid a Drywell Vent path isolation

_____ D. at 214 to avoid a Drywell Vent path isolation Correct Answer : B Precaution 3.5 states: Reactor Water Level should be as near to normal level as possible during manual SRV operation to prevent inadvertent Reactor Hi Level trips due to swell.

This condition results in Reactor Feed Pump Trips.

Plausible Distractors:

A is plausible, if procedural precaution is not known.

C is plausible, if effect of Reactor Pressure induced Reactor Level response from SRV operation is not known. Reactor Low Level Trips result in Drywell Vent Path Isolation..

D is plausible, if procedural precaution and the effect of Reactor Pressure induced Reactor Level response from SRV operation is not known.

Objective Link: ST-OP-315-0005-001-C005

2006 Fermi-2 NRC RO License Exam - Retake RO Tier K/A Number Statement IR Origin Source Question 23 1 295026 EK2.03 3.2 B VY 2002 NRC Exam LOK Grp 10 CFR 55.41(b) 10 LOD (1-5) Reference Documents F (1B) 1 3.4 BWROG EPG /SAG B-7-24 29.100.01 Sheet 2 step TWT-5 QUESTION 22 If Torus Temperature or RPV Pressure cannot be maintained below the Heat Capacity Limit, 29.100.01 Sheet 2, Primary Containment Control, requires Emergency Depressurization.

This action is performed to avoid ____________.

_____ A. loss of all RPV Level instruments after RPV Emergency Depressurization

_____ B. damaging SRV downstream piping during RPV Emergency Depressurization

_____ C. overpressurizing the Primary Containment during RPV Emergency Depressurization

_____ D. excessive hydrodynamic loading on Downcomer piping during RPV Emergency Depressurization Correct Answer : C The Heat Capacity Temperature Limit (HCTL) is the highest suppression pool temperature from which emergency RPV depressurization will not raise Suppression chamber pressure above Primary Containment Pressure Limit.

Plausible Distractors:

A is plausible, High Drywell Temperature challenges RPV Level Instrumentation, addressed in same EOP.

B is plausible, High Torus Level challenges SRV Tailpipe Limit, addressed in same EOP.

D is plausible, Hydrodynamic loading on downcomers is not addressed by HCTL.

Objective Link: LP-OP-802-3004-0009

2006 Fermi-2 NRC RO License Exam - Retake RO Tier K/A Number Statement IR Origin Source Question 7 3 Generic 2.3.4 2.5 N N/A LOK 10 CFR 55.41(b) 12 LOD (1-5) Reference Documents H 3.5 EP-201-03 Rev 8, Section 6.2 (3SPK)

QUESTION 23 Given the following conditions:

  • An accident has occurred which requires life saving measures.
  • Radiation levels in the area of the injured person are 20,000 mrem/hr.
  • Emergency exposure TEDE (Whole Body) limit for life saving operations has been authorized per EP-201-03, Variances From Routine Radiological Practice and Procedures During an Emergency.

The MAXIMUM stay time for a rescuer under these circumstances is:

_____ A. 15 minutes

_____ B. 60 minutes

_____ C. 75 minutes

_____ D. 150 minutes Correct Answer : C 25 Rem = 25,000 mrem/20,000 mrem/hr = 75minutes Plausible Distractors:

A is plausible, 5,000 mrem / 20,000 = 15 minutes.

B is plausible, 20,000 mrem / 20,000 mrem/hr = 60 minutes.

D is plausible, 50,000 mrem / 20,000 mrem/hr = 150 minutes.

Objective Link: LP-GN-508-0001-A015

2006 Fermi-2 NRC RO License Exam - Retake RO Tier K/A Number Statement IR Origin Source Question 25 1 295030 EA1.01 3.6 B Fermi-2 2001 NRC Exam LOK Grp 10 CFR 55.41(b) 10 LOD (1-5) Reference Documents H 1 3.5 29.100.01 Sheet 6 Curves and (3SPR) Cautions Provide RCIC, HPCI, CS, and RHR NPSH Curves and CS, RHR Vortex Curves QUESTION 24 The following plant conditions exist following a LOCA event:

  • Torus Water Temperature is 180 °F (stable).
  • Torus Water Level is -30 (minus 30) inches (stable).
  • Torus Pressure is 0 psig (stable).
  • Reactor Pressure is 70 psig (stable).

Which one of the following describes ACCEPTABLE conditions for the following pumps being used for RPV Level control?

_____ A. RCIC operation at 600 gpm.

_____ B. HPCI operation at 4500 gpm.

_____ C. Single pump LPCI Flow of 12,500 gpm.

_____ D. Total Core Spray Loop Flow of 7000 gpm.

Correct Answer : D CSS NPSH Limit is ~7,600 gpm at -30 (minus 30) inches Torus Level.

Plausible Distractors:

A is plausible, RCIC Pump is restricted to 450 gpm NPSH Limit.

B is plausible, HPCI Turbine has isolated on Low Steam Pressure and flow is limited to 3700 gpm.

C is plausible, RHR Loop Flow over 12,000 gpm exceeds the NPSH Limit.

2006 Fermi-2 NRC RO License Exam - Retake Objective Link: ST-OP-802-3002-001-007

2006 Fermi-2 NRC RO License Exam - Retake RO Tier K/A Number Statement IR Origin Source Question 63 2 264000 K4.01 3.5 B Fermi-2 2003 NRC Exam LOK Grp 10 CFR 55.41(b) 7 LOD (1-5) Reference Documents H 1 3.2 23.307, Rev 90 (3PEO)

QUESTION 25 The plant is in a refueling outage. EDG 11 is running in parallel with Offsite power. 64B-B6, the Normal Offsite Power Feed Breaker, opens spuriously with no faults indicated. How will this affect EDG operation?

_____ A. The EDG will continue to run, Bus 64B will load shed.

_____ B. The EDG will continue to run, ALL EDG trips will remain active.

_____ C. The EDG will continue to run, ONLY essential trips will remain active.

_____ D. The EDG will trip on under frequency and restart, Bus 64B will load shed, and vital loads will sequence back on.

Correct Answer : C Whenever an EDG output breaker is closed, the Undervoltage Relaying for the associated 4160V ESF busses is disabled. The EDG non-essential trips are removed whenever the Normal Feed Breaker (B6, C6, E6, and F6) and Maintenance Tie Breaker (B9, C9, E9, and F9) for that bus are open.

Plausible Distractors:

A is plausible, no Load Shed will occur because Undervoltage Relaying for the associated 4160V ESF buses is disabled.

B is plausible, non-essential trips are removed when the B6 and Maintenance Tie Breaker are open.

D is plausible for a LOOP, non-essential trips are removed when the B6 and Maintenance Tie Breaker are open. No Load Shed will occur because Undervoltage Relaying for the associated 4160V ESF buses is disabled.

Objective Link: ST-OP-315-0065-A016

2006 Fermi-2 NRC RO License Exam - Retake RO Tier K/A Number Statement IR Origin Source Question 27 1 295037 2.4.6 3.1 B Fermi-2 2003 NRC Exam LOK Grp 10 CFR 55.41(b) 10 LOD (1-5) Reference Documents F (1P) 1 2.9 29.ESP.11 Rev 8 QUESTION 26 The plant is in an ATWS. An RO has been assigned to perform 29.ESP.11, Defeat of RPV Level 1 and High Rad MSIV and Main Steam Line Drain Valve Isolation Signals.

Prior to completing the procedure, the MSIVs automatically close on RPV Level.

Where does the assigned operator perform the defeats for this procedure, and how will the MSIVs be affected by performing this procedure after the MSIVs are closed?

_____ A. H11-P601 and H11-P602, MSIVs automatically open after a 30 second time delay.

_____ B. RR H11-P609 and RR H11-P611, MSIVs automatically open with no operator action.

_____ C. RR H11-P609 and RR H11-P611, MSIVs can be manually opened after the isolation signal is reset.

_____ D. H11-P601 and H11-P602, MSIVs can be manually opened by depressing the Inbd and Otbd MSIV OPEN pushbuttons.

Correct Answer : C Defeats are accomplished with jumper installation at P609 and P611, in the Relay Room.

Isolation Reset pushbuttons are performed on P601 and P602, in the Main Control Room.

Isolation Reset is required to facilitate reopening MSIVs.

Plausible Distractors:

A is plausible, there is no automatic MSIV open function. Could be confused for loss of air operation.

B is plausible, correct defeat location, no automatic MSIV open function following an isolation candidate could confuse with loss of air operation.

D is plausible, defeat location is incorrect, reset of isolation signal is required to reopen.

Objective Link: LP-OP-802-3006-0018

2006 Fermi-2 NRC RO License Exam - Retake RO Tier K/A Number Statement IR Origin Source Question 28 1 295038 EK1.02 4.2 M N/A LOK Grp 10 CFR 55.41(b) 10 LOD (1-5) Reference Documents F (1B) 1 2.7 BWROG EPG Appendix B Section 6 QUESTION 27 During an accident condition involving fuel damage and a radiation release, the following conditions exist:

  • Mode Switch is in SHUTDOWN.
  • Reactor Power is 12%.
  • Div 1 AXM Channel 4 is 6.0 microCi/cc (rising).
  • Div 2 AXM Channel 4 is 5.8 microCi/cc (rising).

Why do the EPG BASES permit bypass of the MSIV Level 1 and High Radiation interlocks in this condition?

_____ A. To prevent a threat to Drywell integrity from Hydrogen accumulation.

_____ B. To prevent power oscillations from exceeding the Steam Flow capability of Safety Relief Valves.

_____ C. To allow the Main Condenser in conjunction with the Off Gas System to reduce the dose to the public.

_____ D. To allow Main Steam Line Radiation Monitor data to be used to improve the accuracy of Offsite Dose Calculations.

Correct Answer : C BWROG EPG states; If, instead, high radiation interlocks are not bypassed and steam is discharged through the SRVs into the suppression pool, radionuclides not scrubbed in the pool will accumulate in the containment atmosphere, from which they may escape due to normal containment leakage. Even if processed prior to release by the Standby Gas Treatment System, the public dose will be higher than if these radionuclides were retained in or processed by the Offgas System.

2006 Fermi-2 NRC RO License Exam - Retake Plausible Distractors:

A is plausible, Fuel Damage may be accompanied by Hydrogen generation, which can be a long term containment threat.

B is plausible, other ATWS mitigation actions reduce the probability of fuel damage from core power oscillations.

D is plausible, Main Steam Line Radiation Monitor readings are NOT used for offsite dose calculations.

Objective Link: LP-OP-802-3003-0013 Source Question:

During an accident condition involving fuel damage and a radiation release, the following conditions exist:

Mode Switch is in SHUTDOWN.

Reactor Power is 15%. (MINOR MODIFICATION)

Div 1 AXM Channel 4 is 5.0 microCi/cc (rising). (MINOR MODIFICATION)

Div 2 AXM Channel 4 is 4.8 microCi/cc (rising). (MINOR MODIFICATION)

Why do the EPG BASES permit bypass of the MSIV Level 1 and High Radiation interlocks in this condition?

A. The Turbine Building has a hold up time equivalent to SGTS.

(SIGNIFICANT MODIFICATION)

B. The Main Condenser in conjunction with the Off Gas system will result in a lower dose to the public.

C. The walls of the Main Steam piping and Main Condenser provide one tenth-thickness for gamma attenuation.

(SIGNIFICANT MODIFICATION)

D. The Main Condenser provides a long hold up time by entrainment in the condensate and will result in a lower dose to the public.

(SIGNIFICANT MODIFICATION)

2006 Fermi-2 NRC RO License Exam - Retake RO Tier K/A Number Statement IR Origin Source Question 29 1 600000 AK2.04 2.5 N N/A LOK Grp 10 CFR 55.41(b) 10 LOD (1-5) Reference Documents F (1P) 1 2.75 20.000.18 Rev 39 Action B1 QUESTION 28 Per 20.000.18, Control of the Plant from the Dedicated Shutdown Panel, when a fire develops causing spurious plant equipment operations, the Reactor Protection System Scram Relays are placed in a scram condition by ________________.

_____ A. depressing the RPS Manual Scram Pushbuttons

_____ B. opening the RPS MG Set Power Supply Breakers

_____ C. placing the Reactor Mode Switch in SHUTDOWN

_____ D. placing the APRM Channel Keylock Switches in INOP Correct Answer : A 20.000.18 states, IF Control Room inaccessible as a result of a fire OR actual spurious operation of components or failures of components occur, depress Manual Scram Pushbuttons. Depressing the Manual Scram Pushbuttons is the only manual action performed in the control room that is given credit in the NRC guidance document Generic Letter 86-10, Implementation of Fire Protection Requirements.

Plausible Distractors:

B is plausible, will cause a Reactor Scram and PCIS Isolations, NOT procedurally directed.

C is plausible, will cause a Reactor Scram and defeat the MSL Low Pressure Group 1 Isolation, NOT procedurally directed.

D is plausible, will cause a Reactor Scram, NOT procedurally directed. Plausibility is due to 20.000.19, Shutdown From Outside The Control Room directs this method in non-fire situations.

Objective Link: SS-OP-802-2001-001

2006 Fermi-2 NRC RO License Exam - Retake RO Tier K/A Number Statement IR Origin Source Question 45 2 215004 2.1.30 3.9 B Limerick 2002 NRC Exam LOK Grp 10 CFR 55.41(b) 6 LOD (1-5) Reference Documents H 1 2.3 23.602, Rev 26 (2DR)

QUESTION 29 Plant conditions are as follows:

  • MODE 2, Reactor Startup is in progress.
  • RPS Nuclear Instrumentation shorting links are installed.
  • ALL SRM detectors are fully inserted.
  • The reactor is CRITICAL.
  • ALL IRMs are on Range 2.

SRMs currently indicate:

"A" SRM - 1.4 x 105 cps "B" SRM - 1.1 x 105 cps "C" SRM - 9.2 x 104 cps "D" SRM - 2.3 x 105 cps Per 23.602, Source Range Monitoring System, which one of the following describes the proper positioning of the SRMs and the correct method for withdrawal using the "DRIVE OUT" pushbutton based on the above conditions?

SRM position DRIVE OUT Pushbutton

_____ A. Withdrawn to maintain Depress and hold for continuous SRM withdrawal.

100 to 105 cps.

_____ B. Withdrawn to maintain Depress and release for continuous SRM 100 to 105 cps. withdrawal.

_____ C. Fully withdrawn without Depress and hold for continuous SRM withdrawal.

regard to count rate.

_____ D. Fully withdrawn without Depress and release for continuous SRM regard to count rate. withdrawal.

2006 Fermi-2 NRC RO License Exam - Retake Correct Answer : A 23.602 requires maintaining SRMs on scale between 100 and 105 cps. The procedure specifies depressing and holding the DRIVE OUT pushbutton to withdraw detectors.

Plausible Distractors:

B is plausible, potential misconception - DRIVE IN seals in, requiring only a momentary depress of the pushbutton.

C is plausible, potential misconception - detectors are fully withdrawn only above the Point of Adding Heat, power is given as IRM Range 2.

D is plausible and incorrect on BOTH of the above misconceptions.

Objective Link: ST-OP-315-0022-A014

2006 Fermi-2 NRC RO License Exam - Retake RO Tier K/A Number Statement IR Origin Source Question 30 1 295026 EK3.04 3.7 B Fermi-2 2003 NRC Exam LOK Grp 10 CFR 55.41(b) 10 LOD (1-5) Reference Documents F (1B) 1 2.7 EPG Bases B-6-68 Rev 2 QUESTION 30 The plant has experienced a full power ATWS.

The crew failed to initiate boron injection before Torus water temperature reached the Boron Injection Initiation Temperature (BIIT).

Alternate means to shutdown the reactor have been unsuccessful.

The FIRST limit violated by delayed boron injection is the...

_____ A. Heat Capacity Limit.

_____ B. RPV Saturation Limit.

_____ C. Primary Containment Pressure Limit.

_____ D. Minimum RPV Flooding Pressure Limit.

Correct Answer : A The basis for the BIIT is to assure Hot Shutdown Boron Weight is injected prior to exceeding the Heat Capacity Limit. The Heat Capacity Limit may be violated by delayed boron injection.

Plausible Distractors:

B is plausible, but is simply based on the properties of water.

C is plausible, if ED is initiated AFTER the Heat Capacity Limit is exceeded, PCPL may be violated.

D is plausible, but is dependent upon (1) the Minimum SRV Reopening Pressure or (2) the lowest differential pressure between the RPV and the suppression chamber at which steam flow through the Minimum Number of SRVs Required for Emergency Depressurization is sufficient to remove all decay heat from the core.

Objective Link: ST-OP-802-3002-001-01-06

2006 Fermi-2 NRC RO License Exam - Retake RO Tier K/A Number Statement IR Origin Source Question 31 1 295007 AK3.04 4 N N/A LOK Grp 10 CFR 55.41(b) 7 LOD (1-5) Reference Documents H (2RI/ 2 2.4 1D38, Rev 13 3PEO)

QUESTION 31 The plant was operating at 100 % power when the following transient occurred:

  • A spurious Group 1 Isolation occurred.
  • RPV pressure is 1000 psig (slowly lowering).
  • NO operator actions have occurred.

After 5 minutes, Safety Relief Valve (SRV) (1) is open in the (2) mode.

(1) (2)

_____ A. A Safety

_____ B. G Safety

_____ C. A Low-Low Set

_____ D. G Low-Low Set Correct Answer : C Candidate must know plant response to Full Power Group 1 Isolation. This includes RPV Pressure exceeding High Pressure Scram Setpoint with an SRV Open. This activates Low-Low Set, which reduces Lift Setpoint of Lowest SRV to 1017 psig.

Plausible Distractors:

A/B is plausible, immediately following a MSIV closure scram, these valves could be open due to exceeding their safety relief setpoints (1135 psig).

D is plausible, but is NOT the LOWEST Low-Low Set Lift Setpoint (1047 psig).

Objective Link: ST-OP-315-005-B003

2006 Fermi-2 NRC RO License Exam - Retake RO Tier K/A Number Statement IR Origin Source Question 32 1 295008 AK1.02 2.8 M 1999 Duane Arnold NRC Exam LOK Grp 10 CFR 55.41(b) 5 LOD (1-5) Reference Documents F (1D) 2 2.3 Technical Specification Basis 3.3.2.2 QUESTION 32 With the plant operating at 100% power, if Feedwater Flow EXCEEDS Steam Flow, this condition may result in:

_____ A. CARRYOVER, which reduces NPSH to Jet Pumps.

_____ B. CARRYOVER, which increases erosion of Main Turbine Blades.

_____ C. CARRYUNDER, which reduces NPSH to Reactor Recirculation Pumps.

_____ D. CARRYUNDER, which increases erosion of Steam Separators and Dryers.

Correct Answer : B Candidate must diagnose a condition which produces a HIGH RPV Water Level and select the associated damaging mechanism and susceptible component.

Plausible Distractors:

A is plausible, CARRYOVER does not reduce NPSH to Jet Pumps (wrong effect).

C is plausible, CARRYUNDER (wrong mechanism) can reduce Downcomer Subcooling, which reduces NPSH to Reactor Recirculation Pumps.

D is plausible, Steam Separators and Dryers are designed to operate in a wet steam environment and are not susceptible to moisture erosion.

Objective Link: LP-OP-804-001 Source Question:

One of the running Reactor Feed Pumps was inadvertently TRIPPED while the plant was at 90% power. (SIGNIFICANT MODIFICATION) 1)Does the resultant transient result in CARRYOVER or CARRYUNDER ?

2)What is the primary concern associated with this condition?

A 1) CARRYUNDER 2) Reduction in Recirc Pump Net Positive Suction Head.

B. 1) CARRYOVER 2) Excess moisture impinging the blades of the Main Turbine.

C. 1) CARRYOVER 2) Reduction in Recirc Pump Net Positive Suction Head

2006 Fermi-2 NRC RO License Exam - Retake D. 1) CARRYUNDER 2) Excess moisture impinging the blades of the Main Turbine

2006 Fermi-2 NRC RO License Exam - Retake RO Tier K/A Number Statement IR Origin Source Question 34 1 295012 AK2.02 3.6 B Fermi-2 2001 NRC Exam LOK Grp 10 CFR 55.41(b) 10 LOD (1-5) Reference Documents F (1P) 2 2.4 ARP 8D41 Rev 14 QUESTION 33 The plant is operating at full power with all DW Cooling Fans in operation. SCCW is Out of Service. Panel H11-P808 annunciator 8D41, DIV 1 DRYWELL TEMPERATURE HIGH, alarms. The operator observes that T47-R803A, Drywell Cooling System Area Temperatures Div 1, point 16 indicates 158°F (alarm setpoint is 155°F).

If the AVERAGE drywell temperature has risen from 132°F to 135°F during the last 8 hours0.333 days <br />0.0476 weeks <br />0.011 months <br />, which one of the following actions is appropriate?

_____ A. Start an additional RBCCW Pump.

_____ B. Increase GSW cooling to RBCCW.

_____ C. Manually initiate EECW and EESW Systems.

_____ D. Enter 29.100.01 Sheet 2, Primary Containment Control.

Correct Answer : B ARP 8D41, directs starting all DW Cooling Fans (stem condition), INCREASING GSW to RBCCW HXs, and Starting RBCCW Supplemental Cooling. (stem condition)

Plausible Distractors:

A is plausible, no symptoms are given for inadequate RBCCW Cooling of RBCCW Loads.

C is plausible, EECW is not required for the given conditions.

D is plausible, Primary Containment Control EOP is entered on High Drywell Pressure (1.68 psig) or Drywell Avg Temp > 145ºF. This small amount of temperature increase would not cause the PC to exceed 1.68 psig. The candidate could confuse temperature setpoint and might think pressure would increase greatly.

Objective Link: ST-OP-315-0017-C010

2006 Fermi-2 NRC RO License Exam - Retake RO Tier K/A Number Statement IR Origin Source Question 24 1 295028 EK3.01 3.6 N N/A LOK Grp 10 CFR 55.41(b) 10 LOD (1-5) Reference Documents F (1B) 1 2.9 BWROG EPG/SAG B-7-24 EPG DIFF DOC QUESTION 34 Per 29.100.01, Sheet 2, Primary Containment Control, when Drywell Temperature cannot be restored and maintained below 340 °F, what action is required, and why?

_____ A. Initiate Drywell Sprays to maintain RPV Water Level Instrument Accuracy.

_____ B. Emergency Depressurize because Drywell Design Temperature has been exceeded.

_____ C. Initiate Drywell Sprays prior to reaching conditions which will result in exceeding evaporative cooling limits.

_____ D. Emergency Depressurize to maintain the isolation capability of the Main Steam Isolation Valves (MSIVs).

Correct Answer : B BWROG EPG Basis is the lesser of Drywell Design Temperature or ADS Qualification Temperature, at Fermi-2, these values are BOTH 340°F.

Plausible Distractors:

A is plausible, but the RPV Saturation Curve coupled with erratic level instrument behavior are the criteria for Level Unknown Emergency Depressurization - not 340°F without regard to RPV Pressure. Example, DW=350°F, RPV pressure = 1000 psig, SAT CURVE is not violated.

C is plausible, and is the correct basis for the Drywell Spray Initiation Limit Curve, (DWSIL),

which is also a Drywell Temperature consideration and required at lower Drywell Temperatures.

D is plausible, Containment Integrity is the basis, MSIVs include Outboard Valves which are not subject to DW Temperature and provide isolation capability.

Objective Link: LP-OP-802-3004-009

2006 Fermi-2 NRC RO License Exam - Retake RO Tier K/A Number Statement IR Origin Source Question 35 1 295013 AA2.01 3.8 M 2001 Quad Cities NRC Exam LOK Grp 10 CFR 55.41(b) 10 LOD (1-5) Reference Documents F (1P) 2 2.5 1D61 Rev 19, 20.000.25 Rev 20 QUESTION 35 The plant is operating at 80% power when the following occurs:

  • 1D61, SRV OPEN, alarms.
  • Reactor Pressure is 1025 psig (stable).

Given these conditions, when would the crew be REQUIRED to initiate a manual reactor scram per 20.000.25, Failed Safety Relief Valve ?

_____ A. When Torus Water Average Temperature reaches 95°F.

_____ B. When Torus Water Average Temperature reaches 110°F.

_____ C. Immediately, IF the SRV CANNOT be closed with the pushbuttons.

_____ D. Immediately, IF the SRV CANNOT be closed by pulling control power fuses.

Correct Answer : B AOP 20.000.25, Failed Safety Relief Valve requires manual scram at 110°F Torus Average Water Temperature.

Plausible Distractors:

A is plausible, EOP Entry Condition for 29.100.01, Sheet 2, Primary Containment Control.

C is plausible, 20.000.25 requires Rapid Downpower when pushbuttons fail to close the SRV.

D is plausible, 20.000.25 directs pulling control power fuses, but does not require immediate scram when this is unsuccessful.

Objective Link: SS-OP-802-2001-RO-0003 Source Question:

Unit 2 was operating at 60% power with a HPCI surveillance in progress when the following annunciator was received: (MODIFICATION)

- 3A TARGET ROCK RELIEF VLV OPEN

2006 Fermi-2 NRC RO License Exam - Retake Assuming reactor pressure is normal, when would the crew be REQUIRED to initiate a manual reactor scram?

A. When Torus Bulk Water Temperature reaches 95°F.

B. When Torus Bulk Water Temperature reaches 105°F. (MODIFICATION)

C. Immediately AFTER verifying the safety relief valve (SRV) is actually open.

D. Immediately, IF the SRV is actually open and it CANNOT be closed with the keylock switch. (MODIFICATION)

2006 Fermi-2 NRC RO License Exam - Retake RO Tier K/A Number Statement IR Origin Source Question 36 1 295032 EK2.04 3.6 N N/A LOK Grp 10 CFR 55.41(b) 10 LOD (1-5) Reference Documents H (2RI/ 2 3.0 1D66, Rev 12 3PEO)

QUESTION 36 Following a plant transient, the following conditions exist:

  • RPV Water Level is +190 inches (stable).
  • 1D66, STEAM LEAK DETECTION AMBIENT TEMP HIGH, alarms.
  • 1D70, STEAM LEAK DETECTION DIFF TEMP HIGH, alarms.
  • B21-N600, Main Steam Tunnel Ambient Temperature, reads 160°F.
  • E51-N600, RCIC Ambient (RCIC and CS Room) Temperature, reads 160°F.
  • E41-N600, HPCI Ambient (HPCI and CRD Pump Area) Temperature, reads 135°F.

With these conditions, which one of the following conditions describes the status of Primary Containment Isolation System Valves?

_____ A. ONLY HPCI Valves have received an Isolation Signal.

_____ B. ONLY RCIC Valves have received an Isolation Signal.

_____ C. ONLY Main Steam Isolation Valves AND HPCI Valves have received an Isolation Signal.

_____ D. ONLY Main Steam Isolation Valves AND RCIC Valves have received an Isolation Signal.

Correct Answer : B Since RCIC Equipment Room Temperature exceeds 154°F, a Group 8 Isolation will occur.

Candidate must know PCIS setpoints.

Plausible Distractors:

A is wrong, HPCI Equipment Room is 135°F, Group 6 occurs at 154°F.

C is wrong, MSL Tunnel Temperature is 160°F - Group 1 occurs at 200°F, HPCI Equipment

2006 Fermi-2 NRC RO License Exam - Retake Room is 135°F, Group 6 occurs at 154°F..

D is wrong,, MSL Tunnel Temperature is 160°F - Group 1 occurs at 200°F.

Objective Link: ST-OP-315-0048-B000

2006 Fermi-2 NRC RO License Exam - Retake RO Tier K/A Number Statement IR Origin Source Question 33 1 295010 2.4.31 3.3 N N/A LOK Grp 10 CFR 55.41(b) 10 LOD (1-5) Reference Documents F (1I) 2 2.2 ARP 3D81, Rev 11 QUESTION 37 The plant is operating at 100% power, when the following alarms and indications are received:

When Primary Containment Pressure is at the HIGH alarm setpoint, _______ should occur.

_____ A. NO actuations

_____ B. ONLY a Primary Containment Isolation System (PCIS) actuation

_____ C. ONLY a Reactor Scram AND Emergency Core Cooling System actuation

_____ D. a Reactor Scram AND Emergency Core Cooling System (ECCS) AND Primary Containment Isolation System (PCIS) actuations Correct Answer : A Annunciator Response Procedure 3D81 provides the High (1.50 psig) and Low (0.10) setpoints. The HIGH setpoint is BELOW the 1.68 psig Reactor Scram, ECCS, and PCIS actuation setpoint.

Plausible Distractors:

B is plausible, PCIS actuations occurs at 1.68 psig.

C is plausible, Reactor Scram (RPS) trip and ECCS actuation occurs at 1.68 psig.

D is plausible, Reactor Scram (RPS) trip, ECCS actuation, and PCIS actuation occurs at 1.68 psig.

Objective Link: ST-OP-315-0016-B007

2006 Fermi-2 NRC RO License Exam - Retake RO Tier K/A Number Statement IR Origin Source Question 37 1 295034 EA1.04 4.1 M Fermi-2 2001 NRC Exam LOK Grp 10 CFR 55.41(b) 7 LOD (1-5) Reference Documents F (1I) 2 2.4 3D36, Rev 13 QUESTION 38 The following actions automatically occurred:

  • Reactor Building HVAC automatically tripped.
  • SGTS automatically started.
  • Control Center HVAC automatically aligned to Recirculation Mode.

Which one of the following annunciators is associated with ALL of these actuations?

_____ A. 3D12, DIV 1/2 OFF GAS RADN MONITOR HIGH HIGH

_____ B. 3D36, DIV 1/2 RB VENT EXH RADN MONITOR UPSCALE TRIP

_____ C. 3D46, RW BLDG VENT EXHAUST RADN MONITOR UPSCALE / INOP

_____ D. 3D45, CONT CENTER MAKEUP AIR RADN MONITOR UPSCALE TRIP Correct Answer : B RB Vent Exhaust High Radiation Upscale Trip causes SBGT to initiate, Reactor Building HVAC fans trip and isolate, and Control Center HVAC to shift to the Recirculation Mode.

Plausible Distractors:

A is plausible, Off Gas exits via RB Exhaust Stack.

C is plausible, and is expected during a RW Bldg radiation release, ONLY trips RW Bldg HVAC.

D is plausible, and is expected during a plant radiation release, but ONLY shifts Control Center HVAC to the Recirculation Mode.

Objective Link: ST-OP-315-0066-B003 Source Question:

The following actions automatically occurred as the result of high radiation:

(MODIFICATION)

2006 Fermi-2 NRC RO License Exam - Retake

- Reactor Building HVAC tripped

- SGTS started

- Control Center HVAC aligned to recirculation mode Based on the information provided above, CHOOSE the radiation monitor and indicated radiation level that caused the automatic actions. (MODIFICATION)

A Fuel Pool Vent Exhaust = 7.3 mRem. (MODIFICATION)

B Reactor Building Vent Exhaust = 14,500 cpm. (MODIFICATION)

C Turbine Building Vent Exhaust = 11,500 cpm. (MODIFICATION)

D Radwaste Building Vent Exhaust = 14.5 mRem. (MODIFICATION)

2006 Fermi-2 NRC RO License Exam - Retake RO Tier K/A Number Statement IR Origin Source Question 1 3 Generic 2.1.22 2.8 B N/A LOK 10 CFR 55.41(b) 10 LOD (1-5) Reference Documents F (1D) 3.0 Tech Spec Table 1.1-1 QUESTION 39 Plant conditions are as follows:

Reactor Mode Switch is in the SHUTDOWN position.

Reactor Coolant System Temperature is 120°F.

ALL Control Rods are fully inserted.

ALL Reactor Vessel Head Closure Bolts are NOT fully tensioned.

Per Technical Specifications, which operating MODE is the plant in?

_____ A. MODE 2 (STARTUP)

_____ B. MODE 3 (HOT SHUTDOWN)

_____ C. MODE 4 (COLD SHUTDOWN)

_____ D. MODE 5 (REFUEL)

Correct Answer : D Per Table 1.1-1, MODE 5 (REFUEL) exists when the Reactor Mode Switch is in Shutdown or Refuel at ANY Temperature with one or more Reactor Vessel Head Closure Bolts not fully tensioned.

Plausible Distractors:

A is plausible if candidate incorrectly associates the requirements for MODE 2.

B/C is plausible if candidate does not know the allowance for the Mode Switch to be in SHUTDOWN for MODE 5.

Objective Link: LP-OP-804-0002

2006 Fermi-2 NRC RO License Exam - Retake RO Tier K/A Number Statement IR Origin Source Question 38 2 203000 K4.01 4.2 B N/A LOK Grp 10 CFR 55.41(b) 7 LOD (1-5) Reference Documents H (2RI) 1 2.8 23.205, Rev 94 QUESTION 40 Two minutes after a STEAM leak develops inside the drywell the following conditions exist:

  • Drywell pressure is 13 psig (rising).
  • Reactor pressure is 400 psig (lowering at 10 psig per minute).
  • RPV level is 170 inches (rising).
  • B3105-F031B, Reactor Recirc Pump B Discharge Valve, is CLOSED.

Recirculation Loop (1) has been selected for injection AND on the selected loop, (2) .

_____ A. (1) A (2) BOTH LPCI Injection Valves are OPEN

_____ B. (1) B (2) BOTH LPCI Injection Valves are OPEN

_____ C. (1) A (2) ONE LPCI Injection Valve is CLOSED

_____ D. (1) B (2) ONE LPCI Injection Valve is CLOSED Correct Answer : B The candidate must know that BOTH injection valves are open when RPV Pressure is < 461 psig AND that B is the default Loop Selection when NO Recirculation Loop break is sensed.

Plausible Distractors:

A is plausible, A Loop would be selected if the break was in B Recirculation Loop.

C is plausible, A Loop would be selected if the break was in B Recirculation Loop, ONE valve would be CLOSED if RPV Pressure were > 461 psig.

D is plausible, ONE valve would be CLOSED if RPV Pressure were > 461 psig.

2006 Fermi-2 NRC RO License Exam - Retake Objective Link: ST-OP-315-0041-B000, B003

2006 Fermi-2 NRC RO License Exam - Retake RO Tier K/A Number Statement IR Origin Source Question 39 2 205000 K5.02 2.8 B N/A LOK Grp 10 CFR 55.41(b) 7 LOD (1-5) Reference Documents H 1 2.7 ST-OP-315-0041 Rev 14, 23.205 (2DR/3PEO) Rev 94 QUESTION 41 The plant is in MODE 4 with the following conditions:

  • RHR Pump C is temporarily shutdown to perform Post Maintenance Testing and I&C SDC Surveillances.

The PMT requires E1150-F004C, Division I RHR Pump C Torus Suction Isolation Valve, to be manually opened and closed using the handwheel.

What is the consequence of operating this valve, in this configuration?

_____ A. The Reactor Well and Fuel Pool will drain to the Torus.

_____ B. RHR Pump C will trip on loss of suction flow path when re-started.

_____ C. Water hammer will occur when RHR Pump C is re-started due to loss of fill and vent.

_____ D. RPV level will lower via a drain path from the Reactor Pressure Vessel to the Torus.

Correct Answer : D Suction Path is aligned to the RPV, parallel path would be to the Torus, resulting in an inadvertent RPV drain path to the Torus.

Plausible Distractors:

A is plausible, (MODE 5) If the RPV Head were removed, RPV was Flooded Up, and the FP Gates removed, when the Torus Suction Valve was opened - Reactor Well and Fuel Pool Level would LOWER.

2006 Fermi-2 NRC RO License Exam - Retake B is plausible, if the F004 were closed (Torus Suction Valve) and either the F006 or F008 or F009 (SDC Suction Valves) were closed. Candidate confusion.

C is plausible, if the discharge side of the RHR piping were drained, but this is prevented by an installed check valve.

Objective Link: ST-OP-315-0041-C005

2006 Fermi-2 NRC RO License Exam - Retake RO Tier K/A Number Statement IR Origin Source Question 40 2 206000 K6.02 3.3 B N/A LOK Grp 10 CFR 55.41(b) 7 LOD (1-5) Reference Documents F (1I) 1 2.9 23.202, Rev 89 QUESTION 42 Div 2 ESF DC Distribution 2PB is lost. From the following list, select which response contains the HPCI system steam supply valve(s) that has (have) LOST power.

  • E4150-F002, HPCI Steam Supply Inboard Isolation Valve
  • E4150-F003, HPCI Steam Supply Outboard Isolation Valve
  • E4150-F600, HPCI Steam Supply Outboard Isolation Bypass Valve

_____ A. E4150-F002, HPCI Steam Supply Inboard Isolation Valve ONLY

_____ B. E4150-F003, HPCI Steam Supply Outboard Isolation Valve ONLY

_____ C. BOTH E4150-F002, HPCI Steam Supply Inboard Isolation Valve AND E4150-F003, HPCI Steam Supply Outboard Isolation Valve

_____ D. BOTH E4150-F003, HPCI Steam Supply Outboard Isolation Valve AND E4150-F600, HPCI Steam Supply Outboard Isolation Bypass Valve Correct Answer : D Justification: E4150-F003 and E4150-F600 are powered from MCC 2PB-1.

Plausible Distractors A is plausible, E4150-F002 is powered from MCC 72C-3A.

B is plausible, E4150-F003 is powered from MCC 2PB-1 but is not the only listed valve losing power.

C is plausible, E4150-F002 is powered from MCC 72C-3A, E4150-F003 is powered from MCC 2PB-1.

Objective Link: LP-OP-315-0139-A014

2006 Fermi-2 NRC RO License Exam - Retake RO Tier K/A Number Statement IR Origin Source Question 41 2 209001 A1.07 3.0 B Fermi-2 2003 NRC Exam LOK Grp 10 CFR 55.41(b) 7 LOD (1-5) Reference Documents H (2RI/ 1 2.3 ST-OP-315-0040-001, Rev 14 3PEO)

QUESTION 43 With the plant operating at 100% power, a SIMULTANEOUS Loss of Offsite Power AND Loss of Coolant Accident occurred.

Assuming no other failures, how will the Core Spray system pumps respond?

_____ A. Pumps must be started manually as power is restored to the ESF buses.

_____ B. All pumps automatically start 5 seconds after the EDGs energize the ESF buses.

_____ C. All pumps automatically start immediately after the EDGs energize the ESF buses.

_____ D. Division 1 pumps automatically start 5 seconds after CTG 11-1 energizes the Division 1 ESF buses.

Correct Answer : B Pumps start automatically (5secs) after ESF busses energize on Level 1 or High Drywell Pressure.

Plausible Distractors:

A is plausible, if pump starts were disabled due to Bus Lockout condition.

C is plausible, if candidate doesnt understand logic and basis.

D is plausible, if misconception between Station Blackout and Loss of Offsite Power occurs.

Objective Link: ST-OP-315-0040-B002

2006 Fermi-2 NRC RO License Exam - Retake RO Tier K/A Number Statement IR Origin Source Question 42 2 211000 A2.06 3.1 M Fermi-2 2003 NRC Exam LOK Grp 10 CFR 55.41(b) 8 LOD (1-5) Reference Documents H 1 3.0 23.139 Rev 40 (3SPK)

QUESTION 44 The SLC Initiation Keylock Switch, C4100- M004, has been placed in the PMP A RUN position.

The following indications are noted 30 seconds later:

  • Reactor Pressure is 1000 psig.
  • C41-R601, SLC Tank Level Indicator, is steady.
  • SLC Continuity Lights A and B are ON.
  • SLC Pump A CMC Switch, red light is ON, green light is OFF.
  • C41-R600, SLC Pump Discharge Pressure Indicator, is oscillating between 1370 and 1320 psig.

These are indications of what condition, and what should the operator do?

_____ A. SLC Explosive Valves failed to fire; start SLC Pump B.

_____ B. Normal operation for the SLC System; monitor SLC Tank level.

_____ C. C41-F001, SLC Storage Tank Outlet Valve, is shut; dispatch an operator to open C41-F001.

_____ D. C41-F029A, SLC Pump A Discharge Relief Valve, failed open; dispatch an operator to gag shut C41-F029A.

Correct Answer : A If the C41-F004A & B, failed to fire, positive displacement SLC Pump A will OPEN C41-F029A, SLC Pump A Discharge Relief Valve, which causes pressure oscillations between 1370 and 1320 psig. These are the lift and reseat pressures for C41-F029A. Starting SLC Pump B will fire the other primer in both valves.

2006 Fermi-2 NRC RO License Exam - Retake Plausible Distractors:

B is plausible, Normal Indication would be Discharge Pressure slightly higher than Reactor Pressure AND lowering SLC Tank Level.

C is plausible, the Tank Level would remain steady if the Storage Tank Outlet were shut, but discharge pressure would be low.

D is plausible, Relief Valve has opened, but has not failed.

Objective Link: LP-OP-315-0114-C010 Source Question:

On direction from the CRS, an operator has placed the SLC Initiation Keylock Switch (C4100 M004) in the PMP A Run position.

The following indications are noted 30 seconds later:

"C41 LIR601 (SLC Tank Level) steady "Primer circuit continuity indicators OFF "SLC pump A red light ON, green light OFF "C41 PI R600 (SLC Pump Discharge Pressure) pulsating at 1400 psig (MODIFICATION)

These are indications of what condition, and what should the operator do?

A Normal operation for the SLC System; monitor SLC Tank level.

B C41-F004A, Pump A Squib Valve, failed to fire; start SLC pump B.

C C41-F001, SLC Storage Tank Outlet Valve, is open; dispatch operator to close C41-F001.

(MODIFICATION)

D C41-F029A, SLC Pump A Discharge Relief Valve, failed open; dispatch operator to gag open C41-F029A. (MODIFICATION)

2006 Fermi-2 NRC RO License Exam - Retake RO Tier K/A Number Statement IR Origin Source Question 43 2 212000 A3.05 3.9 B Clinton 2001 NRC Exam LOK Grp 10 CFR 55.41(b) 7 LOD (1-5) Reference Documents H 1 2.5 3D94, Rev 7; 3D113, Rev 20; 3D6, (2DR/ Rev 9 3PEO)

QUESTION 45 A plant startup is in progress. Reactor Pressure is stable at 100 psig, when the following alarms are received.

  • 3D2, SCRAM DISCH VOLUME HIGH
  • 3D73, TRIP ACTUATORS A1 / A2 TRIPPED
  • 3D74, TRIP ACTUATORS B1 / B2 TRIPPED
  • 3D94, DISCH WATER VOL HIGH LEVEL CHANNEL TRIP Based on these conditions, which one of the following describes the status of the following annunciators?

(1) 3D113, CONTROL ROD WITHDRAWAL BLOCKED (2) 3D6, SCRAM VALVE PILOT AIR HDR PRESS HIGH / LOW (1) (2)

_____ A. Clear Clear

_____ B. Clear Alarming

_____ C. Alarming Clear

_____ D. Alarming Alarming Correct Answer : D Scram Discharge Volume High Level Trip causes BOTH Rod Block and Scram.

Plausible Distractors:

A is plausible, if SDV Level RPS Trip and Rod Block functions are not known.

B is plausible if Rod Block function is not known.

C is plausible if RPS Trip function is not known.

2006 Fermi-2 NRC RO License Exam - Retake Objective Link: ST-OP-315-0027-001-A013

2006 Fermi-2 NRC RO License Exam - Retake RO Tier K/A Number Statement IR Origin Source Question 44 2 215003 A4.05 3.4 M Fitzpatrick 2003 NRC Exam LOK Grp 10 CFR 55.41(b) 7 LOD (1-5) Reference Documents F (1I) 1 2.4 3D59, Rev 5 QUESTION 46 Intermediate Range Monitor (IRM) Upscale RPS Trips are BYPASSED when _____________.

_____ A. the IRM is on Range 8

_____ B. ALL APRMs are downscale

_____ C. ALL SRMs are fully inserted

_____ D. the Reactor Mode Switch is in RUN Correct Answer : D IRM Trips are bypassed with the Reactor Mode Switch in RUN.

Plausible Distractors:

A is plausible, SRM Upscale Trips are BYPASSED when IRMs are on Range 8.

B is plausible, potential misconception with Companion Trips.

C is plausible. potential misconception with SRM Detector Retract Not Permitted.

Objective Link: ST-OP-315-0023-A016 Source Question:

An IRM HI Flux Control Rod Block is automatically bypassed when___________?

(MODIFICATION)

A The IRM is on Range 1. (MODIFICATION)

B The SRM's are fully inserted.

C The IRM's companion APRM is downscale. (MODIFICATION)

D The Reactor Mode Switch is placed in RUN.

2006 Fermi-2 NRC RO License Exam - Retake RO Tier K/A Number Statement IR Origin Source Question 46 2 215005 K1.16 3.3 N N/A LOK Grp 10 CFR 55.41(b) 6 LOD (1-5) Reference Documents:

H 1 3.5 3D119, Rev 10; 3D115, Rev 9 (3PEO)

QUESTION 47 With Reactor Power at 100%, the following alarms and indications occur:

  • 3D115, APRM FLOW UPSCALE
  • B31-R617, Recirc A Loop Flow Indicator, is UNCHANGED at 42 KGPM.
  • B31-R613, Recirc B Loop Flow Indicator, is UNCHANGED at 42 KGPM.
  • Reactor Power is UNCHANGED at 100%.
  • B31-R614, Recirc Loops Flow Recorder, indicates UPSCALE on Loops A and B.

What is the effect of this failure and what is the proper crew response?

_____ A. This will cause OPRM protection to be enabled. Bypass RBM A.

_____ B. This will cause OPRM protection to be enabled. Bypass APRM Channel 1.

_____ C. This will prevent OPRM protection from becoming enabled. Bypass RBM A.

_____ D. This will prevent OPRM protection from becoming enabled. Bypass APRM Channel 1.

Correct Answer : D APRM Channel 1 provides Recirc Loop A and Loop B flow signals to B31-R614, Recirc Loops A and B Flow Recorder. OPRMs are enabled ONLY below 60% Recirc Flow and Simulated Thermal Power greater than 28%. OPRM protection for APRM 1 is prevented and cannot be enabled.

Plausible Distractors:

A/C are plausible, RBM processes flow unit input to IPCS only.

B is plausible, however low flow is required to enable OPRM protection.

2006 Fermi-2 NRC RO License Exam - Retake Objective Link: ST-OP-315-0024-A015

2006 Fermi-2 NRC RO License Exam - Retake RO Tier K/A Number Statement IR Origin Source Question 47 2 217000 K2.01 2.8 N N/A LOK Grp 10 CFR 55.41(b) 7 LOD (1-5) Reference Documents F (1F) 1 2.4 23.206, Rev 83 QUESTION 48 When 480 VAC MCC 72F becomes DEENERGIZED, which one of the following RCIC valves will lose power?

_____ A. E5150-F095, RCIC Turbine Steam Inlet Bypass Valve

_____ B. E5150-F007, RCIC Steam Line Inboard Isolation Valve

_____ C. E5150-F008, RCIC Steam Line Outboard Isolation Valve

_____ D. E5150-F084, RCIC Exhaust Vacuum Breaker Inboard Isolation Valve Correct Answer : B E5150-F007, RCIC Steam Line Inboard Isolation Valve is powered from 480 VAC MCC 72F-4A Pos 4D.

Plausible Distractors:

A is plausible, but is powered from D1 DC MCC 2PA-1 pos 7C.

C is plausible, but is powered from D1 DC MCC 2PA-1 Pos 3A.

D is plausible, but is powered from D2 DC MCC 2PB-1 Pos 6C. It is also an inboard primary containment isolation valve, which in most cases is located in the primary containment and AC powered. This valve is located outside of the primary containment. (Torus Room)

Objective Link: ST-OP-315-0043-A014

2006 Fermi-2 NRC RO License Exam - Retake RO Tier K/A Number Statement IR Origin Source Question 48 2 218000 K3.01 4.4 M Dresden 2002 NRC Exam LOK Grp 10 CFR 55.41(b)7 LOD (1-5) Reference Documents H 1 3.3 1D44 Rev 12, 1D31 Rev 10 (3PEO)

QUESTION 49 A transient occurs, resulting in the following conditions:

  • HPCI is operating and injecting into the vessel.
  • RPV Water Level is 35 inches, lowering one inch per minute.
  • Reactor pressure is 900 psig and slowly lowering.
  • Drywell pressure is 1.0 psig and trending up at 0.05 psig/min.
  • 1D57, ADS/SRV/EECW TCV POWER SUPPLY FAILURE, alarms.
  • 2PA2-5 Circuit 1 is de-energized and cannot be restored.

3 minutes later, the following H11-P601 panel annunciators alarm:

  • 1D31, ADS DRYWELL PRESS BYPASS TIMER INITIATE A / B LOGIC
  • 1D36, ADS ECCS PUMP CH B PERMISSIVE From the receipt of the alarms, the EARLIEST that ADS Valves should be AUTOMATICALLY OPENED, is:

_____ A. 2 minutes

_____ B. 7 minutes

_____ C. 9 minutes

_____ D. Never (valves remain closed)

Correct Answer : C Annunciators indicate that L1 (31.8 inches) has occurred.

L1 + 7 minutes (DW Bypass Timer) = 7 minutes + 105 seconds = 8 minutes and 45 seconds ADS Valves OPEN. Loss of 2PA2-5 disables ADS Logic A, but ADS Logic B is powered and

2006 Fermi-2 NRC RO License Exam - Retake has dual power supplies (2PA2-5 & 2PA2-6). ADS Logic B is sufficient to initiate ADS.

Plausible Distractors:

A is plausible, 105 seconds from L1, IF Hi DW Pressure existed, this would be correct.

B is plausible, 7 minutes from L1, candidate may select if misconception exists about logic and 105 sec timer.

D is plausible, if candidate believes loss of 2PA2-5 will disable both logic trains/systems.

Objective Link: ST-OP-315-0042-B003 Source Question:

At 10:44, the following conditions exist on Unit 2:

A Steam Line Break occurred in the Drywell (MODIFICATION)

The MSIVs are closed HPCI is operating and injecting to the vessel RPV Water Level is -45 inches and trending down at two inches per minute (MODIFICATION)

Reactor pressure is 900 psig and steady Drywell pressure is 1.5 psig, rising at 0.2 psig per minute (MODIFICATION)

At 10:47, the following 902-3 panel annunciators alarm:

ADS PERMISSIVE DW PRESSURE HIGH (E-15) (MODIFICATION)

ADS TIMER START (B-13)

LPCI/CS PP AT PRESS (H-13)

ADS INHIBIT (G-11) (MODIFICATION)

What is the state of this reactor at 10:54? (MODIFICATION)

A Reactor Water Level is still trending down (MODIFICATION)

B HPCI is maintaining level in the vessel (MODIFICATION)

C All five ADS relief valves are open (MODIFICATION)

D LPCI and Core Spray pumps are running and injecting water into the vessel(MODIFICATION)

2006 Fermi-2 NRC RO License Exam - Retake RO Tier K/A Number Statement IR Origin Source Question 49 2 223002 K4.06 3.4 B Fermi-2 2003 NRC Exam LOK Grp 10 CFR 55.41(b) 7 LOD (1-5) Reference Documents F (1I) 1 3.2 23.427, Rev 18; ST-OP-315-0048-001, Rev 11 QUESTION 50 The plant is in Mode 4 with RHR Loop A operating in the Shutdown Cooling Mode.

A RHR Shutdown Cooling Isolation has occurred.

Which one of the following lists the MINIMUM condition(s) and/or action(s) which will allow Shutdown Cooling Suction Valves to be reopened?

_____ A. ONLY the initiating condition must be corrected and restored to normal.

_____ B. ONLY Main Steam Line Isolation RESET pushbuttons on H11-P601 and H11-P602 must be depressed.

_____ C. The initiating condition must be corrected and restored to normal AND Main Steam Line Isolation RESET pushbuttons on H11-P601 and H11-P602 must be depressed.

_____ D. The initiating condition must be corrected and restored to normal AND the close push button on the affected isolation valves must be depressed AND ONLY the Main Steam Line Isolation RESET pushbutton on H11-P601 must be depressed.

Correct Answer : C RHR SDC Valves may be reopned after the initiating condition has been corrected and restored to normal AND Main Steam Line Isolation RESET pushbuttons on H11-P601 and H11-P602 have been depressed.

Plausible Distractors:

A is plausible, but is inadequate to permit reopening SDC Valves.

B is plausible, but is inadequate to permit reopening SDC Valves.

D is plausible, but is not the MINIMUM conditions / actions.

2006 Fermi-2 NRC RO License Exam - Retake Objective Link: ST-OP-0048-A015

2006 Fermi-2 NRC RO License Exam - Retake RO Tier K/A Number Statement IR Origin Source Question 59 2 211000 K6.03 3.2 N N/A LOK Grp 10 CFR 55.41(b) 7 LOD (1-5) Reference Documents H (2RI) 1 3.5 23.106 Rev 85, 23.139 Rev 41 QUESTION 51 Following a LOSS OF OFFSITE POWER, the following conditions exist:

  • Reactor Power is 20%.
  • EDG 13 FAILED to start.
  • Power to ESF Bus 72B has been LOST.

Which one of the following pumps IS AVAILABLE for reactivity control?

_____ A. C4103-C001A, SLC PUMP A

_____ B. C4103-C001B, SLC PUMP B

_____ C. C1106-C001A, EAST CRD PUMP

_____ D. C1106-C001B, WEST CRD PUMP Correct Answer : C Bus 64B is the power supply to CRD Pump A Plausible Distractors:

A is plausible, SLC Pump A is an ATWS reactivity control system pump, but is fed from Bus 72B. This bus lost power (given in stem). Candidate must know power supply.

B is plausible, SLC Pump B is an ATWS reactivity control system pump, but is fed from Bus 72E. EDG 13 failed to start (given in stem) which would supply its power supply (72E).

D is plausible, W. CRD Pump is an ATWS reactivity control system pump, but is fed from Bus 65E. EDG 13 failed to start (given in stem) which would supply its power supply (65E).

Objective Link: ST-OP-315-0010-A014

2006 Fermi-2 NRC RO License Exam - Retake RO Tier K/A Number Statement IR Origin Source Question 50 2 239002 K5.06 2.7 B Grand Gulf 2002 NRC Exam LOK Grp 10 CFR 55.41(b)3 LOD (1-5) Reference Documents:

F (1B) 1 2.6 ST-OP-315-0005-001 Rev 15 QUESTION 52 Which one of the following describes the function of the Safety Relief Valve Tailpipe Vacuum Breakers?

_____ A. Relieve steam from the SRV tailpipes following SRV actuation to the Drywell to prevent excessive back pressure on the SRV discs.

_____ B. Relieve differential pressures built up in the SRV tailpipes following actuation that would result in lift pressures for SRVs which are in excess of design.

_____ C. Equalize pressure established in the SRV tailpipes to assure positive actuation of the SRV Tailpipe Pressure Switches for accurate SRV position indication.

_____ D. Equalize pressure conditions in the SRV tailpipes to prevent Torus water from being drawn into the piping which could result in excessive hydraulic loads.

Correct Answer : D SRV Tailpipe Vacuum Breakers prevent condensing steam in the Tailpipe from drawing Torus Water upward into the Tailpipe, which would result in water slug flow on subsequent lifts, which may produce excessive hydraulic loads.

Plausible Distractors:

A is a plausible, but incorrect function.

B is a plausible, but incorrect function.

C is a plausible, but incorrect function.

Objective Link: ST-OP-315-0005-A008

2006 Fermi-2 NRC RO License Exam - Retake RO Tier K/A Number Statement IR Origin Source Question 26 1 295031 EA2.04 4.6 N N/A LOK Grp 10 CFR 55.41(b) 10 LOD (1-5) Reference Documents H 1 2.8 29.100.01, RPV Control, Sheet 1 (2DR)

QUESTION 53 Following a transient, plant conditions are:

  • Drywell Pressure is 8 psig.
  • NO ECCS Pumps are running.
  • NO High OR Low Pressure Injection systems are running.

Which of the following is the LOWEST stable RPV Water Level which assures Adequate Core Cooling?

_____ A. TOP of Active Fuel

_____ B. 25 inches BELOW the Top of Active Fuel

_____ C. 40 inches BELOW the Top of Active Fuel

_____ D. 48 inches BELOW the Top of Active Fuel Correct Answer : C Minimum Zero Injection Water Level is by EOP Flowcharts -40 inches.

Plausible Distractors:

A is plausible, TAF assures Adequate Core Cooling, but is NOT the LOWEST.

B is plausible, and is the lower limit, if Injection Systems are operating.

D is plausible, if BOTH Core Spray Pumps in one loop are operating.

Objective Link: ST-OP-802-3001-001-01-08

2006 Fermi-2 NRC RO License Exam - Retake RO Tier K/A Number Statement IR Origin Source Question 51 2 259002 K6.05 3.5 N N/A LOK Grp 10 CFR 55.41(b)7 LOD (1-5) Reference Documents H (2RI/ 1 3.1 23.107, Rev 106 3PEO) ST-OP-315-0046-001 Rev 13 QUESTION 54 With the plant operating at 100% power, the following conditions are present:

  • REACTOR LEVEL SELECT Switch is in the A LEVEL position.
  • C32-R618, Master Feedwater Level Controller, is set at 197 inches.
  • C32-R606A, Reactor Level A Indicator, reads 197 inches.
  • C32-R606B, Reactor Level B Indicator, reads 196 inches.
  • C32-R606C, Reactor Level C Indicator, reads 198 inches.
  • C32-R606D, Reactor Level D Indicator, reads 197 inches.

IF C32-R606A, Reactor Level A Indicator, INSTANTANEOUSLY FAILS to 160 inches, how will the plant respond?

_____ A. ACTUAL Reactor Water Level will RISE until an indirect Reactor Scram occurs.

_____ B. ACTUAL Reactor Water Level will LOWER one inch, control has automatically shifted to Reactor Level Channel B.

_____ C. ACTUAL Reactor Water Level will RISE one inch, control has automatically shifted to Reactor Level Channel C.

_____ D. ACTUAL Reactor Water Level will NOT CHANGE, control has automatically shifted to the Median of the three remaining channels.

Correct Answer : D If the lead selected RPV water level signal, A or B fails, DCS logic will automatically transfer RPV water level control and the input to C32-R618, Master Feedwater Level Controller, to the Median signal of the three remaining RPV water level signals. This will cause ACTUAL Level to NOT CHANGE because the median signal was the same as the pre-failure value of Level Channel A.

2006 Fermi-2 NRC RO License Exam - Retake Plausible Distractors:

A is plausible, if the candidate does not know Level Control automatically transfers.

B is plausible, if the candidate does not know that the Level Control Channel automatically transfers to the median signal. Level B is also the other selectable Lead Channel.

C is plausible, if the candidate does not know that the Level Control automatically transfers to the median signal. Channel C is an available level channel.

Objective Link: ST-OP-315-0046-B001

2006 Fermi-2 NRC RO License Exam - Retake RO Tier K/A Number Statement IR Origin Source Question 52 2 261000 A1.04 3.0 B N/A LOK Grp 10 CFR 55.41(b) 10 LOD (1-5) Reference Documents H (2RI) 1 3.2 29.100.01 Sheet 5, Rev 7 EPG Bases page B-8-1 QUESTION 55 Drywell Pressure is 2 psig. Div 1 SGTS is in service with Div 2 SGTS OUT OF SERVICE for maintenance. The following indications occur:

  • 8D35, DIV I SGTS AIR FLOW STOPPED, alarms
  • T4600-F004A, Div 1 SGTS Exhaust Fan Inlet Isolation Damper, is CLOSED This will result in a condition which FIRST requires entry into the:

_____ A. Radiation Release Control EOP Leg to ensure that any airborne radioactive material, in the Secondary Containment, is not released to the surrounding atmosphere.

_____ B. Secondary Containment Control EOP Leg to ensure that unfiltered airborne radioactive material, in the Secondary Containment, is not released to the surrounding atmosphere.

_____ C. Secondary Containment Control EOP Leg to limit the maximum temperatures for equipment located in the Secondary Containment which is necessary to place the plant in a stable shutdown condition.

_____ D. Radiation Release Control EOP Leg to place the plant in a condition which reduces the motive force for radioactive material release from inside the Secondary Containment to the environs.

Correct Answer : B High Drywell Pressure indication implies that Reactor Building Ventilation has tripped and isolated. Low Secondary Containment D/P requires Secondary Containment Control EOP Entry to ensure that any airborne radioactive material in the Secondary Containment is not released to the surrounding atmosphere without passing through the SGTS filters.

2006 Fermi-2 NRC RO License Exam - Retake Plausible Distractors:

A is plausible, Radiation Release EOP Leg may be required AFTER radioactivity is released without passing through the SGTS filters.

C is plausible, High Area Temperatures is a Secondary Containment Control EOP Leg entry, but SGTS does not effectively limit Area Temperatures, due to having no supply cooling.

D is plausible, radiation releases may be limited by reducing plant pressure, which reduces steam leakage and motive force. NO radiation release conditions are given.

Objective Link: LP-OP-315-0120-C011

2006 Fermi-2 NRC RO License Exam - Retake RO Tier K/A Number Statement IR Origin Source Question 53 2 262001 A2.02 3.6 B N/A LOK Grp 10 CFR 55.41(b) 7 LOD (1-5) Reference Documents H (2RI/ 1 2.3 23.307, Rev. 90 3PEO)

QUESTION 56 The following conditions exist:

  • Reactor power is 98%.
  • Drywell Pressure is 1.1 psig, rising slowly.
  • Reactor Water Level is 185 inches, lowering slowly.

If the pressure and level trends continue, what can the operator expect to happen to the Emergency Diesel Generators (EDG), AND what action should be taken?

_____ A. EDG will auto start. Dispatch an operator to load the EDG for at least 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br />.

_____ B. EDG auto starts, load shed occurs. Dispatch an operator to load the EDG for at least 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br />.

_____ C. EDG will auto start and the EDG output breaker will close. Dispatch an operator to verify proper operation of the EDG.

_____ D. EDG will auto start, the EDG output breaker will close, and loads will be sequenced on to the EDG. Dispatch an operator to verify proper operation of the EDG.

Correct Answer : A BOTH Low RPV Water Level 1 and High Drywell Pressure will automatically start EDGs.

Since Offsite Power has not been lost, EDG will run unloaded with the Output Breaker open.

Procedure 23.307 requires loading for at least 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> before stopping an automatically started EDG.

Plausible Distractors:

B is plausible, Loads wont shed without a loss of power. Offsite Power is available, so no Load Shed will occur.

C is plausible, EDG will auto start. Offsite Power is available, so EDG Output Breaker will

2006 Fermi-2 NRC RO License Exam - Retake not close.

D is plausible, EDG will auto start. Offsite Power is available, so EDG Output Breaker will not close.

Objective Link: ST-OP-315-0065-B003

2006 Fermi-2 NRC RO License Exam - Retake RO Tier K/A Number Statement IR Origin Source Question 54 2 262002 A3.01 2.8 N N/A LOK Grp 10 CFR 55.41(b) 7 LOD (1-5) Reference Documents H (2RI) 1 3.2 23.308.01, Rev. 25 QUESTION 57 The following indications exist:

  • 3D22, UPS UNIT A / B TROUBLE, alarms.
  • Reactor Building Operator reports that R3100S011, UPS Bus A Inverter DC Input Breaker, is OPEN.

Given these indications, which one of the following describes UPS distribution status?

_____ A. UPS Bus A loads are de-energized, the DC Input Breaker must be repaired to restore power to UPS Bus A loads.

_____ B. UPS Bus A loads remain energized, the STATIC SWITCH automatically aligns loads to the Alternate Source.

_____ C. UPS Bus A loads are de-energized, MANUAL TRANSFER Switch operation is necessary to restore power to UPS Bus A loads.

_____ D. UPS Bus A loads remain energized, the STATIC SWITCH automatically aligns inverter to the UPS Bus B Rectifier Output.

Correct Answer : B A low voltage output is sensed at the output of the static inverter and the STATIC SWITCH automatically aligns loads to the Alternate Source.

Plausible Distractors:

A is plausible, UPS Inverters A and B can share DC, but if Inverter A DC Input Breaker trips, the UPS A Inverter will have no power.

C is plausible, if Inverter and Static Switch are damaged, this is the appropriate method.

D is plausible, DC Input Power is shared between UPS A and B, AC Output is not.

Objective Link: ST-OP-315-0062-B003

2006 Fermi-2 NRC RO License Exam - Retake RO Tier K/A Number Statement IR Origin Source Question 55 2 263000 A4.01 3.3 N N/A LOK Grp 10 CFR 55.41(b) 7 LOD (1-5) Reference Documents F (1I) 1 2.75 20.300.260VESF, Rev 1 QUESTION 58 With a loss of Division 1 ESF 260/130 VDC Batteries and Chargers, which one of the following will result?

_____ A. Breakers on 4160V Busses 65E and 13EC will lose control power.

_____ B. C11-F110A, Scram Pilot Air Header Backup Scram Valve, will actuate.

_____ C. MCC 72CF Feed will auto throw-over from 72C Pos 3C to 72F Pos 5C.

_____ D. Breakers CM and CF will not open on generator relaying or with the manual control switches on COP H11-P804.

Correct Answer : C Div 1 ESF Batteries provide control power to Div 1 ESF buses, breakers, and MCC 72CF Breaker auto throw-over function. (This is the LPCI Swing MCC.) There are no Control Room operated DC Power Breakers. Loss of Div 1 control power will cause MCC 72CF to shift from being supplied from Div 1 to Div 2 power.

Plausible Distractors:

A is plausible, but is associated with Division 2 ESF 260 / 130 VDC Batteries and Chargers.

B is plausible, correct source, but loss of power prevents Backup Scram Valve actuation.

D is plausible, but is a failure mode associated with loss of BOP Batteries and Chargers.

Objective Link: ST-OP-315-0064-A016

2006 Fermi-2 NRC RO License Exam - Retake RO Tier K/A Number Statement IR Origin Source Question 57 2 300000 K1.05 3.1 N N/A LOK Grp 10 CFR 55.41(b) 7 LOD (1-5) Reference Documents H (2RI/ 1 2.7 20.129.01, Rev 25 3PEO)

QUESTION 59 The plant is operating at 100% power, when the following occurs:

  • 7D54, INTERRUPTIBLE CONTROL AIR HEADER PRESS LOW, alarms.
  • P50-R870, IAS Header Pressure Indicator, reads 80 psig (lowering).

If this trend continues, which one of the following describes the component(s) AND failure mode(s) which will require the Reactor Mode Switch to be placed in SHUTDOWN per 20.129.01, Loss of Station and/or Control Air?

_____ A. An Inboard MSIV begins to CLOSE due to loss of IAS.

_____ B. An Outboard MSIV begins to CLOSE due to loss of IAS.

_____ C. A Control Rod drifts in due to C11-F002A, CRD Flow Control Valve, failing OPEN due to loss of IAS.

_____ D. A Control Rod Drive Hydraulic Pump TRIPS on Low Suction Pressure due to C11-F412, CRD Pump Suction Pressure Control Valve, failing SHUT due to loss of IAS.

Correct Answer : B Outboard MSIVs are supplied by IAS and close at approximately 50 psig.

Plausible Distractors:

A is plausible, Inboard MSIVs may begin to CLOSE, if Division 1 Non Interruptible Air is lost.

C is plausible, failure mode of C11-F002A is CLOSED, so Control Rods will not drift in due to this failure.

D is plausible, although complete loss of CRD may require the Reactor Mode Switch placed in

2006 Fermi-2 NRC RO License Exam - Retake SHUTDOWN immediately during some other plant conditions, the CST provides a redundant suction supply to the CRD Hydraulic Pumps. The operating CRD Pump should remain in service.

Objective Link: SS-OP-802-2001-RO-0004

2006 Fermi-2 NRC RO License Exam - Retake RO Tier K/A Number Statement IR Origin Source Question 58 2 400000 K2.01 2.9 N N/A LOK Grp 10 CFR 55.41(b) 7 LOD (1-5) Reference Documents F (1F) 1 2.75 23.127, Rev 103 QUESTION 60 With the plant operating at 100% power, when the following occurs:

  • 9D10, DIV 1 480 V ESS BUS 72C BKR TRIPPED, alarms.
  • CMC Switch for BUS 64C POS C11, 4160V FEED TO BUS 72C, indicates TRIPPED.

Given these indications, which of the following correctly describes the impact on the Reactor Building Closed Cooling Water (RBCCW) Pumps?

_____ A. ONLY P4200-C001, North RBCCW Pump, loses power.

_____ B. ONLY P4200-C003, South RBCCW Pump, loses power.

_____ C. BOTH P4200-C001 AND P4200-C002, North and Center RBCCW Pumps, lose power.

_____ D. BOTH P4200-C003 AND P4200-C002, South and Center RBCCW Pumps, lose power.

Correct Answer : A Bus 72C is the power supply to the North RBCCW Pump.

Plausible Distractors:

B is plausible, P4200-C003, South RBCCW Pump is powered from Bus 72E.

C/D is plausible, P4200-C002, Center RBCCW Pump is powered from Bus 72F.

Objective Link: ST-OP-315-0067-A014

2006 Fermi-2 NRC RO License Exam - Retake RO Tier K/A Number Statement IR Origin Source Question 60 2 212000 A1.04 2.8 N N/A LOK Grp 10 CFR 55.41(b) 7 LOD (1-5) Reference Documents H 1 2.8 23.316, Rev 46 (3PEO)

QUESTION 61 With the plant operating with normal electrical alignment at 100% power, RPS Bus A Voltage begins lowering. The FIRST protective action which will result is a trip of the:

_____ A. RPS MG Set A Motor Breaker.

_____ B. RPS MG Set A Output Breaker.

_____ C. C7100-S003C, RPS MG Set A EPA Circuit Breaker.

_____ D. C7100-S003G, RPS Alternate Transformer A EPA Circuit Breaker.

Correct Answer : C C7100-S003C, EPA Circuit Breaker trips at 109 VAC.

High Cognitive Level due to recognizing normal RPS alignment and breaker trip hierarchy.

Plausible Distractors:

A s plausible, only Motor trips are 175 amps, loss of 480 vac power, and overheating 230°F.

B is plausible, but is not the FIRST., Output Breaker trips at 108 VAC.

D is plausible, this is the RPS A Alternate Power EPA, not normally in service.

Objective Link: ST-OP-315-0027-A008

2006 Fermi-2 NRC RO License Exam - Retake RO Tier K/A Number Statement IR Origin Source Question 61 2 215003 K3.01 3.9 N N/A LOK Grp 10 CFR 55.41(b) 7 LOD (1-5) Reference Documents H 1 2.7 3D59, Rev 6 (3PEO) 3D63, Rev 5 QUESTION 62 During a reactor start-up with all IRMs reading 30 on Range 5, IRM E Range Selector Switch is repositioned to Range 4.

This will cause a:

_____ A. Rod Block ONLY.

_____ B. Half Scram ONLY.

_____ C. Half Scram on RPS Trip Channel A AND a Rod Block.

_____ D. Half Scram on RPS Trip Channel B AND a Rod Block.

Correct Answer : C When E IRM Range switch is repositioned to Range 4, indication goes from 30/40 to 300/125, which results in an IRM High-High condition. This results in a RPS Trip Channel A Trip and a Rod Block.

Plausible Distractors:

A is plausible, but is only partially correct.

B is plausible, but is only partially correct.

D is plausible, but incorrect, RPS Trip Channel A is associated with IRM E.

Objective Link: ST-OP-315-0023-B002 NRC NOTE: Based on questions asked by candidates during the written exam, the licensee changed the highlighted numbers. The reason for the change: odd ranges for IRMs are 0 - 40!

2006 Fermi-2 NRC RO License Exam - Retake RO Tier K/A Number Statement IR Origin Source Question 62 2 262001 K5.01 3.1 N N/A LOK Grp 10 CFR 55.41(b) 7 LOD (1-5) Reference Documents H 1 2.9 23.307, Rev 90 (3PEO)

QUESTION 63 When paralleling an EDG with Offsite Power, if SYNCH BUS Starting Volts are 12 volts higher than SYNCH BUS Running Volts, which one of the following conditions will result when the EDG Output Breaker is CLOSED?

_____ A. The Emergency Diesel Generator will be reverse powered by the grid.

_____ B. Excessive Reactive Power will flow from the Emergency Diesel Generator to the grid.

_____ C. Excessive Reactive Power will flow from the grid to the Emergency Diesel Generator.

_____ D. Excessive True Power will be picked up from the grid by the Emergency Diesel Generator.

Correct Answer : B KA Statement, principles of paralleling two AC sources KA tie is the proper division of reactive load by adjustment of pre-synchronization settings. Approximate voltage match.

Plausible Distractors:

A is plausible, will happen if Governor Setting is too low.

C is plausible, will happen if Voltage Regulator Setting is too low.

D is plausible, will happen if Governor Setting is too high.

Objective Link: ST-OP-315-0065-A016

2006 Fermi-2 NRC RO License Exam - Retake RO Tier K/A Number Statement IR Origin Source Question 64 2 201001 A1.01 3.1 B 2004 Clinton NRC Exam LOK Grp 10 CFR 55.41(b) 5 LOD (1-5) Reference Documents H 2 2.8 ST-OP-315-0010, Rev 14 (3PEO)

QUESTION 64 The plant is operating at normal pressure with C11-F002A, CRD Drive Water A Flow Control Valve, in service and in AUTOMATIC control.

The following CRD indications are present:

  • Cooling water flow is 45 gpm.
  • Drive water D/P is 225 psid.
  • Cooling water D/P is 15 psid.

When C1152-F003, CRD Drive/Cooling Water Pressure Control Valve, is adjusted in the CLOSED direction, what will be the FINAL effect on the CRD System parameters?

_____ A. Drive Water D/P INCREASES and Cooling Water Flow DECREASES.

_____ B. Drive Water D/P DECREASES and Cooling Water Flow DECREASES.

_____ C. Drive Water D/P INCREASES and Cooling Water Flow REMAINS THE SAME.

_____ D. Drive Water D/P DECREASES and Cooling Water Flow REMAINS THE SAME.

Correct Answer : C When the Pressure Control Valve is throttled CLOSED, Drive Water D/P increases, due to lower flow through the CRD Pump. The FCV is in AUTO and automatically maintains Cooling Water Flow stable.

Plausible Distractors:

A is plausible, but is incorrect because cooling water flow remains the same with FCV in AUTO. Correct if the CRD FCV was in MANUAL.

B/D is plausible, but is incorrect because drive water D/P increases. Could be selected if misconception exists about location of PCV. (For example: If PCV was located upstream of

2006 Fermi-2 NRC RO License Exam - Retake Cooling Water Header.)

Objective Link: ST-OP-315-0010-A015

2006 Fermi-2 NRC RO License Exam - Retake RO Tier K/A Number Statement IR Origin Source Question 65 2 202002 2.1.28 3.2 N N/A LOK Grp 10 CFR 55.41(b) 7 LOD (1-5) Reference Documents F (1P) 2 3.2 23.138.01, Rev 88 QUESTION 65 The RECIRC MANUAL RUNBACK pushbutton causes a speed reduction in:

_____ A. ONLY RR MG Sets in AUTO and automatically resets when the RR MG Set speed adjustments are completed.

_____ B. RR MG Sets in AUTO or MANUAL and automatically resets when the RR MG Set speed adjustments are completed.

_____ C. ONLY RR MG Sets in AUTO and is RESET by operation of the RECIRC RUNBACK RESET A (B) pushbutton.

_____ D. RR MG Sets in AUTO or MANUAL, and is RESET by operation of the RECIRC RUNBACK RESET A (B) pushbutton.

Correct Answer : B RECIRC RUNBACK RESET A (B) pushbutton is used to reset automatic runbacks from the speed limiters. Manual Runbacks automatically reset when speed adjustments are completed.

Plausible Distractors:

A is plausible, Manual Runbacks automatically reset when speed adjustments are completed.

Misconception may exist that speeds are only reduced in Auto.

C is plausible, RR MG Set speeds are reduced in Auto or Manual. Misconception may exist that speeds are only reduced in Auto.

D is plausible, RR MG Set speeds are reduced in Auto or Manual. Manual Runbacks automatically reset when speed adjustments are completed.

Objective Link: ST-OP-315-0004-C001

2006 Fermi-2 NRC RO License Exam - Retake RO Tier K/A Number Statement IR Origin Source Question 66 2 204000 K1.08 3.7 B LaSalle 2003 NRC Exam LOK Grp 10 CFR 55.41(b) 7 LOD (1-5) Reference Documents F (1I) 2 2.3 23.139, Rev 41 QUESTION 66 Which of the following describes the DIRECT response of the Reactor Water Cleanup System when the Standby Liquid Control System is initiated?

_____ A. The operating RWCU pumps trip.

_____ B. The operating RWCU Filter Demineralizers go into HOLD.

_____ C. G3300-F033, RWCU Blowdown Flow Control Valve, automatically closes.

_____ D. G3352-F004, RWCU Supply Outboard Isolation Valve, AND G3352-F220, RWCU to Feedwater Outboard Containment Isolation Valve, CLOSE.

Correct Answer : D SBLC Initiation directly causes G3352-F004, RWCU Supply Outboard Isolation Valve AND G3352-F220, RWCU to Feedwater Outboard Containment Isolation Valve to CLOSE.

Plausible Distractors:

A is plausible, this is an indirect trip, on G3352-F004 Not Full Open. Valve gets close signal and closes, leaving full open limit switch (5% closed/95% open). Full open contact in pump trip string, closes, tripping the pump.

B is plausible, this is an indirect effect. Sensed Low F/D Flow will cause F/Ds to transfer to HOLD.

C is plausible, but is NOT an interlock associated with SBLC.

Objective Link: ST-OP-315-0008-B007

2006 Fermi-2 NRC RO License Exam - Retake RO Tier K/A Number Statement IR Origin Source Question 67 2 215002 K2.03 2.8 N N/A LOK Grp 10 CFR 55.41(b) 7 LOD (1-5) Reference Documents H 2 3.5 9D70, Rev 16, VMR1-82.1 (3PEO)

QUESTION 67 With the plant operating at 100% power, the following occur:

  • 3D103, APRM TROUBLE, alarms.
  • 9D70, DIV I 120V RPS BUS 1A POWER FAILURE, alarms.

Which one of the following describes the impact of this failure?

_____ A. ALL APRM Channels are operable AND a Half Scram has occurred.

_____ B. APRM Channel 1 indicates INOP trip AND a Half Scram has occurred.

_____ C. APRM Channels 1 and 3 indicate INOP trip AND a Full Scram has occurred.

_____ D. ALL APRM Channels are operable AND ONLY a Control Rod Block has occurred.

Correct Answer : A APRMs have a QLVPS powered from both RPS A and B in an auctioneered manner. Loss of one RPS power supply will cause a non-critical self-test fault only. No functions will be affected. Loss of RPS A side causes a half scram, not from APRMs.

Plausible Distractors:

B is plausible, based on former design of PRNM.

C is plausible, based on former design of PRNM and misconception of new design requiring any 2 APRMs for a full scram.

D is plausible, APRMs are not affected. The Half scram is a result of the loss of RPS bus 1A.

Objective Link: ST-OP-315-0024-B002

2006 Fermi-2 NRC RO License Exam - Retake RO Tier K/A Number Statement IR Origin Source Question 56 2 264000 2.4.31 3.3 N N/A LOK Grp 10 CFR 55.41(b) 7 LOD (1-5) Reference Documents H (2RI/ 1 3.0 9D44, Rev 4, 9D66, Rev 4 3PEO)

QUESTION 68 Following a Loss of Offsite Power, EDGs 11 and 12 are operating supplying their respective ESF Busses. The following alarms are received:

  • 9D44, DIV I EDG 11 FUEL OIL PRESSURE LOW.
  • 9D66, DIV I EDG 12 CRANKCASE PRESSURE HIGH.

Given these indications, which one of the following describes the status of the Emergency Diesel Generators?

_____ A. BOTH EDGs trip immediately.

_____ B. BOTH EDGs continue to operate.

_____ C. EDG 11 continues to operate. EDG 12 trips immediately.

_____ D. EDG 11 trips immediately. EDG 12 continues to operate.

Correct Answer : C After an emergency start, only essential trips are active. Fuel oil low pressure is not an essential trip.

Plausible Distractors:

Other choices are plausible if EDG logic and/or essential and non-essential trips are not known.

Objective Link: ST-OP-315-0065-B003

2006 Fermi-2 NRC RO License Exam - Retake RO Tier K/A Number Statement IR Origin Source Question 68 2 216000 A2.08 3.2 N N/A LOK Grp 10 CFR 55.41(b) 5 LOD (1-5) Reference Documents H 2 3.5 Provide: 29.100.01, Rev 6 Cautions (3SPR) and Curves QUESTION 69 A plant transient has resulted in the following conditions:

  • Reactor Pressure is 100 psig.
  • Drywell Temperature is 360°F.

B21-R605, RPV Flood Up Level Indicator, is (1) . The LOWEST value at which this instrument may be used is (2) .

(1) (2)

_____ A. accurate at an indicated RPV level of 200

_____ B. unreliable at an indicated RPV level of 220

_____ C. unreliable at an indicated RPV level of 240

_____ D. unreliable at an indicated RPV level of 280 Correct Answer : C Reference Leg heating due to Drywell High Temperature causes B21-N027 to indicate HIGHER than actual RPV Water Level. EOP Procedures restrict instrument use to ONLY RPV Levels above the Minimum Indicated Level. The Saturation Curve must be used to determine if in unreliable region. 240 and 280 inches are above the minimum but 240 is the lowest.

Plausible Distractors:

Distractors are plausible, if candidate does not use EOP curves and tables correctly.

Objective Link: ST-OP-802-3002-01-05

2006 Fermi-2 NRC RO License Exam - Retake RO Tier K/A Number Statement IR Origin Source Question 69 2 226001 K4.10 2.9 B Fermi-2 2003 NRC Exam LOK Grp 10 CFR 55.41(b) 7 LOD (1-5) Reference Documents H 2 3.1 ST-OP-315-0041, Rev 14 (3PEO)

QUESTION 70 A LOCA has occurred. The following conditions exist:

  • Reactor Pressure is 200 psig, stable.
  • Reactor Water Level is 30 inches, stable.
  • ADS is INHIBITED.
  • Drywell Pressure 20 psig and slowly lowering.
  • Division 2 RHR is aligned to the vessel through B Loop.
  • E1150-F010, RHR Crosstie Valve, is OPEN.

A subsequent loss of 345 Kv Offsite Power and failure of EDGs 13 and 14 result in Reactor Water Level falling to -50 (minus 50) inches on the Core Level Instruments. What is the expected RHR system response?

_____ A. Division 1 Containment Spray and Cooling valves will close. Division 1 RHR discharge pressure will increase and Division 1 RHR will inject to the vessel through Division 1.

_____ B. Division 1 Containment Spray and Cooling valves will close. Division 1 RHR discharge pressure will increase and Division 1 RHR will inject to the vessel through Division 2.

_____ C. Division 1 Containment Spray and Cooling valves will remain open. Division 1 RHR discharge pressure will decrease and Division 1 RHR will inject to the vessel through Division 1.

_____ D. Division 1 Containment Spray and Cooling valves will remain open. Division 1 RHR discharge pressure will decrease and Division 1 RHR will inject to the vessel through Division 2.

2006 Fermi-2 NRC RO License Exam - Retake Correct Answer : B 2/3 Core Height (Level 0 = -42 inches) Isolates Containment Cooling, ONLY Division 2 valves are affected by subsequent LOOP since Division 2 EDGs failed to start. LPCI remains selected to the B Loop.

Plausible Distractors:

Distractors are plausible, identifying power supply misconceptions and the effect on the remaining RHR Pumps and LPCI flowpath.

Objective Link: ST-OP-315-0041-A016

2006 Fermi-2 NRC RO License Exam - Retake RO Tier K/A Number Statement IR Origin Source Question 71 2 241000 K6.08 3.6 N N/A LOK Grp 10 CFR 55.41(b) 7 LOD (1-5) Reference Documents:

H 2 3.2 ST-OP-315-0045, Rev 12 (3PEO)

QUESTION 71 The following conditions exist:

  • Reactor power is 65%.
  • RPV Pressure is 1010 psig.
  • Turbine Flow Limiter setting is 70%.
  • Reactor Flow Limiter setting is 115%.
  • Pressure Regulator No. 1 is in service set at 944 psig.

A transient occurs that results in a reactor power increase to 85% CTP. This causes:

_____ A. Turbine Control Valves to CLOSE and will result in an RPS actuation from TCV Fast Closure.

_____ B. Turbine Control Valves to OPEN and will result in an RPS actuation associated with RPV Level.

_____ C. Turbine Control Valves AND Bypass Valves to OPEN. NO RPS actuations are expected to occur.

_____ D. Turbine Control Valves to AND Bypass Valves to OPEN. This transient will be terminated by RPS actuation associated with RPV Pressure.

Correct Answer : C An increase in reactor power causes TCVs to open. The BPVs will open on pressure control once power rises to 70% based on Turbine Flow Limiter setting. Steam flow will not exceed the BPV capacity (25%) and reactor pressure and power will rise. No RPS actuations will occur.

Plausible Distractors:

A is plausible, if misconception about Pressure Control mode exists. This is plausible if TCVs initially CLOSE due to a Trip signal.

B is plausible, if misconception about plant effects exist. High steam flow could cause

2006 Fermi-2 NRC RO License Exam - Retake lowering level, if makeup capability is inadequate. The Feedwater system can handle a 20%

power change.

D is plausible, if BPV capacity is exceeded.

Objective Link: ST-OP-315-0045-A016

2006 Fermi-2 NRC RO License Exam - Retake RO Tier K/A Number Statement IR Origin Source Question 72 2 256000 A4.03 3.2 B Fermi-2 2001 NRC Exam LOK Grp 10 CFR 55.41(b) 7 LOD (1-5) Reference Documents H (2RI) 2 3.6 5D131, Rev 9 QUESTION 72 The following plant conditions exist:

  • 5D131, SOUTH HOTWELL LEVEL HIGH/LOW, in alarm.
  • N61-R805, South Hotwell Primary/Backup Level Indicator, indicates 49 inches (lowering)

Which statement describes the plant status for the given conditions?

_____ A. Condenser Pumps, tripped Heater Feed Pumps, tripped Reactor Feed Pumps, tripped

_____ B. Normal Hotwell Supply Pump auto started.

N2000-F620, Condenser Hotwell Relief Station Bypass Valve, closed N20-F407, Condenser Hotwell Normal Makeup LCV, open (> 90% indicated)

_____ C. Normal and Emergency Hotwell Supply Pumps are running.

N20-F406, Condenser Hotwell Emergency Makeup LCV, open (> 20% indicated)

N20-F407, Condenser Hotwell Normal Makeup LCV, open (> 90% indicated)

_____ D. N20-F406 Condenser Hotwell Emergency Makeup LCV, closed (0% indicated)

N20-F407, Condenser Hotwell Normal Makeup LCV, closed (0% indicated)

N2000-F636, Condenser Hotwell Emergency Makeup Bypass Valve, closed Correct Answer : B At 50 inches Hotwell Level, with the Condenser Hotwell Normal Makeup LCV 90% open, the Normal Hotwell Supply Pump Auto starts.

Plausible Distractors:

A is plausible on Low Hotwell Level, but no trips have been reached.

C is plausible, but Emergency Makeup Level has not been reached, Emergency pump has not started, Emergency Makeup LCV has not opened.

2006 Fermi-2 NRC RO License Exam - Retake D is plausible, correct alignment for Normal Hotwell Levels.

Objective Link: ST-OP-315-0006-A015

2006 Fermi-2 NRC RO License Exam - Retake RO Tier K/A Number Statement IR Origin Source Question 74 2 271000 K6.08 2.9 N N/A LOK Grp 10 CFR 55.41(b) 7 LOD (1-5) Reference Documents F (1P) 2 2.75 6D2, Rev 9 QUESTION 73 With the plant operating at 100% power and Hydrogen Water Chemistry (HWC) in service, the following occurs:

  • 6D2, SJAE STEAM PRESSURE HIGH / LOW, alarms.

The effect of the above conditions on the Off Gas System is:

_____ A. LOW Off Gas System Flow.

_____ B. LOW Off Gas Oxygen Concentration.

_____ C. HIGH Off Gas Hydrogen Concentration.

_____ D. HIGH Off Gas Radiation Monitor Indication.

Correct Answer : A The SJAEs isolate with steam pressure < 50 psig and condenser vacuum will decrease, per the ARP. With no condenser non-condensables and steam flow through the SJAEs, Off Gas system flow will decrease.

Plausible Distractors:

B is plausible, with no flow, no Hydrogen is available for recombination, Oxygen concentration rises.

C is plausible, this is an AOP indication for a wet recombiner.

D is plausible, this is an AOP indication for failed fuel cladding. Low System Flow will cause LOW Radiation Monitor Readings. Slower process flow allows as shorter lived nuclides to decay prior to reaching the monitor.

Objective Link: ST-OP-315-0035-B003

2006 Fermi-2 NRC RO License Exam - Retake RO Tier K/A Number Statement IR Origin Source Question 73 2 259001 K5.03 2.8 N N/A LOK Grp 10 CFR 55.41(b) 10 LOD (1-5) Reference Documents F (1P) 2 3.0 23.107 Rev 106 QUESTION 74 According to 23.107, Reactor Feedwater and Condensate Systems, the Reactor Feed Pump Turbines should be warmed for:

_____ A. 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> at 1000 rpm ONLY.

_____ B. 6 hours0.25 days <br />0.0357 weeks <br />0.00822 months <br /> at 1600-1800 rpm ONLY.

_____ C. 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> at 1000 rpm AND 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> at 1600-1800 rpm.

_____ D. 6 hours0.25 days <br />0.0357 weeks <br />0.00822 months <br /> at 1000 rpm AND 6 hours0.25 days <br />0.0357 weeks <br />0.00822 months <br /> at 1600-1800 rpm.

Correct Answer : C 23.107. Precaution and Limitation 3.1.7 states, Each RFPT should be warmed for 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> at 1000 rpm and 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> at 1600-1800 rpm.

Plausible Distractors:

A is plausible, partial statement of warming requirements.

B and D are plausible because these are the old requirements for the S. RFPT before the drain piping was modified.

Objective Link: ST-OP-315-0007-B005

2006 Fermi-2 NRC RO License Exam - Retake RO Tier K/A Number Statement IR Origin Source Question 75 2 290002 K3.03 3.3 N N/A LOK Grp 10 CFR 55.41(b) 7 LOD (1-5) Reference Documents H 2 3.6 20.138.02 Rev 23 (3 PEO)

QUESTION 75 With the plant operating at 100% power, the following indications are observed:

  • B21-R609A, Jet Pump 15 Flow, lowered from 5.0x106 to 0 lb/hr.
  • B21-R611A, Jet Pumps 11-20 Loop A Flow, lowered from 44x106 to 39 x106 lb/hr.
  • B31-R617, Recirc A Loop Flow, increased from 30,000 to 34,000 gpm.
  • B21-R613, Reactor Core DP Indicator, lowered from 32 to 22 psid.

This will cause Reactor Power to:

_____ A. RISE AND APRM Simulated Thermal Power Upscale Trip Setpoint to RISE.

_____ B. RISE AND APRM Simulated Thermal Power Upscale Trip Setpoint to LOWER.

_____ C. LOWER AND APRM Simulated Thermal Power Upscale Trip Setpoint to RISE.

_____ D. LOWER AND APRM Simulated Thermal Power Upscale Trip Setpoint to LOWER.

Correct Answer : C Indications are given for a Jet Pump separation. Lower Reactor Core DP indicates lower ACTUAL Core Flow which LOWERS Reactor Power. Recirc A Loop Flow Increased which raises APRM Simulated Thermal Power Upscale Trip Setpoint.

Plausible Distractors:

A is plausible, if misconception about Recirc Loop Flow vs Jet Pump Loop Flow effect on Reactor Power exists. (Recirc Runaway)

B is plausible, if misconception about Recirc Loop Flow vs Jet Pump Loop Flow effect on Reactor Power exists AND flow instrument input to APRM Flow exists.

D is plausible is misconception about flow instrument input to APRM Flow exists.

Objective Link: ST-OP-315-0004-C011