Line 3: Line 3:
| issue date = 06/30/2011
| issue date = 06/30/2011
| title = Notification of Inspection (NRC Inspection Report 05000445/2011004, 05000446/2011004) and Request for Information
| title = Notification of Inspection (NRC Inspection Report 05000445/2011004, 05000446/2011004) and Request for Information
| author name = Farnholtz T R
| author name = Farnholtz T
| author affiliation = NRC/RGN-IV/DRS/EB-1
| author affiliation = NRC/RGN-IV/DRS/EB-1
| addressee name = Flores R
| addressee name = Flores R
Line 14: Line 14:
| page count = 5
| page count = 5
}}
}}
See also: [[followed by::IR 05000445/2011004]]
See also: [[see also::IR 05000445/2011004]]


=Text=
=Text=
{{#Wiki_filter:UNITED STATES NUCLEAR REGULATORY  
{{#Wiki_filter:UNITED STATES
COMMISSION  
                                  NUCLEAR REGULATORY COMMISSION
REGION IV Rafael Flores, Senior Vice President  
                                                    REGION IV
and Chief Nuclear Officer Luminant Generation  
                                          612 EAST LAMAR BLVD, SUITE 400
Company LLC Comanche Peak Nuclear Power Plant P.O. Box 1002 Glen Rose, TX 76043 612 EAST LAMAR BLVD, SUITE 400 ARLINGTON, TEXAS 76011-4125
                                            ARLINGTON, TEXAS 76011-4125
June 30, 2011 SUBJECT: COMANCHE PEAK NUCLEAR POWER PLANT, UNITS 1 AND 2 -NOTIFICATION  
                                              June 30, 2011
OF INSPECTION (NRC INSPECTION  
Rafael Flores, Senior Vice President
REPORT 05000445/2011004;  
  and Chief Nuclear Officer
05000446/2011004)  
Luminant Generation Company LLC
AND REQUEST FOR INFORMATION  
Comanche Peak Nuclear Power Plant
Dear Mr. Flores: On August 15, 2011, the U.S. Nuclear Regulatory  
P.O. Box 1002
Commission (NRC) will begin the onsite portion of the Gas Accumulation  
Glen Rose, TX 76043
Management  
SUBJECT:       COMANCHE PEAK NUCLEAR POWER PLANT, UNITS 1 AND 2 -
in Emergency  
                NOTIFICATION OF INSPECTION (NRC INSPECTION REPORT
Core Cooling, Decay Heat Removal, and Containment  
                05000445/2011004; 05000446/2011004) AND REQUEST FOR INFORMATION
Spray Systems Temporary  
Dear Mr. Flores:
Instruction  
On August 15, 2011, the U.S. Nuclear Regulatory Commission (NRC) will begin the onsite
at your Comanche Peak Nuclear Power Plant, Units 1 and 2. This inspection  
portion of the Gas Accumulation Management in Emergency Core Cooling, Decay Heat
will be performed  
Removal, and Containment Spray Systems Temporary Instruction at your Comanche Peak
in accordance  
Nuclear Power Plant, Units 1 and 2. This inspection will be performed in accordance with NRC
with NRC Temporary  
Temporary Instruction (TI) 2515/177.
Instruction (TI) 2515/177.  
Experience has shown that this inspection is resource intensive both for the NRC inspectors
Experience  
and your staff. In order to minimize the impact to your onsite resources and to ensure a
has shown that this inspection  
productive inspection, we have enclosed a request for documents needed for this inspection.
is resource intensive  
The documents have been divided into two groups.
both for the NRC inspectors  
* The first group lists information necessary for our initial inspection scoping and in-office
and your staff. In order to minimize the impact to your onsite resources  
    preparation activities. This information should be separated by information request number,
and to ensure a productive  
    especially if provided electronically (e.g., folder with the information request number). This
inspection, we have enclosed a request for documents  
    information should be available to the inspector no later than August 1, 2011. Upon review of
needed for this inspection.  
    these documents, the inspectors will select additional documentation for review upon arrival.
The documents  
    By August 10, 2011, the inspector will communicate the initial selected samples.
have been divided into two groups. * The first group lists information  
* The second group of documents requested is needed to support our onsite inspection
necessary  
    activities. This set of documents should be available to the inspector on August 15, 2011. It
for our initial inspection  
    is also requested that corrective action documents and responses to questions developed
scoping and in-office  
    during the inspection be provided to the inspector as the documents are generated.
preparation  
We have discussed the schedule for these inspection activities with your staff and understand
activities.  
that our regulatory contact for this inspection will be Gary Merka of your licensing organization.
This information  
If there are any questions about this inspection or the materia! requested, please contact the
should be separated  
inspector, Matt Young, at 817-276-6545 or by email at '-'-==:.J:-==~=~='
by information  
 
request number, especially  
                                                -2-
if provided electronically (e.g., folder with the information  
This letter does not contain new or amended information collection requirements subject to the
request number). This information  
Paperwork Reduction Act of 1995 (44 U.S.C. 3501 et seq.). Existing information collection
should be available  
requirements were approved by the Office of Management and Budget, control number
to the inspector  
3150-0011. The NRC may not conduct or sponsor, and a person is not required to respond to,
no later than August 1, 2011. Upon review of these documents, the inspectors  
a request for information or an information collection requirement unless the requesting
will select additional  
document displays a currently valid Office of Management and Budget control number.
documentation  
In accordance with Code of Federal Regulations, Title 10, Part 2.390 of the NRC's Rules of
for review upon arrival. By August 10, 2011, the inspector  
Practice, a copy of this letter and its enclosure will be available electronically for public
will communicate  
inspection in the NRC Public Document Room or from the Publicly Available Records (PARS)
the initial selected samples. * The second group of documents  
component of NRC's document system (ADAMS). ADAMS is accessible from the NRC Web
requested  
site at                                               (the Public Electronic Reading Room).
is needed to support our onsite inspection  
                                              Thomas R. Farnholtz, Chief
activities.  
                                              Engineering Branch 1
This set of documents  
                                              Division of Reactor Safety
should be available  
Dockets: 50-445; 50-446
to the inspector  
Licenses: NPF-87; NPF-89
on August 15, 2011. It is also requested  
Enclosure: Management of Gas Accumulation in Emergency Core Cooling, Decay Heat
that corrective  
Removal, and Containment Spray Systems Temporary Instruction Document Request
action documents  
cc w/encl:
and responses  
Distribution via ListServ for Comanche Peak
to questions  
 
developed  
    MANAGEMENT OF GAS ACCUMULATION IN EMERGENCY CORE COOLING, DECAY
during the inspection  
  HEAT REMOVAL, AND CONTAINMENT SPRAY SYSTEMS TEMPORARY INSTRUCTION
be provided to the inspector  
                                      DOCUMENT REQUEST
as the documents  
        inspection Report:                     05000445/2011004; 05000446/2011004
are generated.  
        On-site Inspection Dates:              August 15-19, 2011
We have discussed  
        Inspection Procedure:                  TI 2515/177, "Management of Gas Accumulation in
the schedule for these inspection  
                                                Emergency Core Cooling, Decay Heat Removal, and
activities  
                                                Containment Spray Systems"
with your staff and understand  
        Lead InspectorlTeam Leader:            Matt Young
that our regulatory  
                                                817 -276-6545
contact for this inspection  
                                                Matt.young@nrc.gov
will be Gary Merka of your licensing  
The following information should be sent to the Region IV office in hard copy or electronic
organization.  
format (ims.certrec.com or compact disc, preferred), in care of Matt Young, to facilitate the
If there are any questions  
selection of specific items that will be reviewed during the onsite inspection week. The
about this inspection  
inspector will select specific items from the information requested below and then request from
or the materia! requested, please contact the inspector, Matt Young, at 817-276-6545  
your staff additional documents needed during the onsite inspection weeks. Also, we request
or by email at
that you categorize the documents in your response with the numbered list below. Please
-2 -This letter does not contain new or amended information  
provide requested documentation electronically if possible. If requested documents are large
collection  
and only hard copy formats are available, please inform the inspector(s), and provide subject
requirements  
documentation during the first day of the onsite inspection. If you have any questions regarding
subject to the Paperwork  
this information request, please call the inspector as soon as possible.
Reduction  
I. Information Requested By August 1, 2011
Act of 1995 (44 U.S.C. 3501 et seq.). Existing information  
    1. List of corrective action program documents (with a short description) associated with
collection  
        Generic Letter (GL) 2008-01, voids in piping, and pressure transients for the previous
requirements  
        three years.
were approved by the Office of Management  
    2. List of changes (with a short description and tracking number) to the final safety analysis
and Budget, control number 3150-0011.  
        report (FSAR), technical specifications, technical specification bases, and technical
The NRC may not conduct or sponsor, and a person is not required to respond to, a request for information  
        requirements manual associated with the resolution of GL 2008-01.
or an information  
    3. List of calculations associated with GL 2008-01, including calculations that have been
collection  
        changed or created in response to GL 2008-01 (with a short description of the
requirement  
        calculation and the change).
unless the requesting  
    4. List (with a short description) of gas intrusion mechanisms that apply to the plant and the
document displays a currently  
        affected system locations (e.g. identify the source, conditions, and expected void
valid Office of Management  
        locations).
and Budget control number. In accordance  
    5. List of the suction piping sections identified as susceptible to gas accumulation (the list
with Code of Federal Regulations, Title 10, Part 2.390 of the NRC's Rules of Practice, a copy of this letter and its enclosure  
        should identify the corresponding system).
will be available  
                                              - 1-                                       Enclosure
electronically  
 
for public inspection  
6. List of the discharge piping sections identified as susceptible to gas accumulation (the
in the NRC Public Document Room or from the Publicly Available  
    list should identify the corresponding system).
Records (PARS) component  
7.   Copies of isometric drawings of the emergency core cooling, residual heat removal, and
of NRC's document system (ADAMS). ADAMS is accessible  
    containment spray systems (hard-copies are preferred).
from the NRC Web site at (the Public Electronic  
8. Copies of piping and instrumentation diagrams (P&IDs) of the emergency core cooling,
Reading Room). Dockets: 50-445; 50-446 Licenses:  
    residual heat removal, and containment spray systems (hard-copies are preferred).
NPF-87; NPF-89 Thomas R. Farnholtz, Chief Engineering
9. Copies of program documents and procedures developed to implement the resolution of
Branch 1 Division of Reactor Safety Enclosure:
    GL 2008-01.
Management  
10. List of actions that were completed in response to GL 2008-01.
of Gas Accumulation  
11. Copies of the modification packages for hardware modifications as part of the resolution
in Emergency  
    of GL 2008-01.
Core Cooling, Decay Heat Removal, and Containment  
12. Design basis documents of the emergency core cooling, residual heat removal, and
Spray Systems Temporary  
    containment spray systems.
Instruction  
13. Design basis documents of keep-full systems of the emergency core cooling, residual
Document Request cc w/encl: Distribution  
    heat removal, and containment spray systems.
via ListServ for Comanche Peak
14. System walkdown reports associated with the resolution of GL 2008-01.
MANAGEMENT  
15. If applicable, provide a list of inaccessible locations where plant walkdowns of the
OF GAS ACCUMULATION  
    emergency core cooling, residual heat removal, and containment spray systems have
IN EMERGENCY  
    not been completed. Include an explanation of why each area is considered
CORE COOLING, DECAY HEAT REMOVAL, AND CONTAINMENT  
    inaccessible.
SPRAY SYSTEMS TEMPORARY  
16. Copies of surveillance procedures associated with the resolution of GL 2008-01 and the
INSTRUCTION  
    results of the last two surveillances for the emergency core cooling, residual heat
DOCUMENT REQUEST inspection  
    removal, and containment spray systems.
Report: On-site Inspection
17. Copies of procedures used for detecting and determining void volumes.
Dates: Inspection
18. Copies of procedures used for filling and venting.
Procedure:
19. Copies of trends of periodic venting results.
Lead InspectorlTeam
20. Copies of the engineering evaluations performed for all identified voids in the past three
Leader: 05000445/2011004;  
    years.
05000446/2011004  
21. Basis for the void acceptance criteria (e.g. calculation). If applicable, provide the
August 15-19, 2011 TI 2515/177, "Management  
    justification for any deviation from the void acceptance criteria established by the Office
of Gas Accumulation  
    of Nuclear Reactor Regulation (NRR).
in Emergency  
22. Copy of any void transport analyses.
Core Cooling, Decay Heat Removal, and Containment  
                                          -2-                                         Enclosure
Spray Systems" Matt Young 817 -276-6545  
 
Matt.young@nrc.gov  
    23. Copy of vortexing calculations associated with systems under the scope of GL 2008-01.
The following  
    24. Copies of self-assessments associated with the implementation of the GL 2008-01
information  
        program.
should be sent to the Region IV office in hard copy or electronic  
II. Information Requested By August 15,2011
format (ims.certrec.com  
    25. Copies of the selected corrective action program documents.
or compact disc, preferred), in care of Matt Young, to facilitate  
    26. Copies of the selected licensing and design basis document changes.
the selection  
    27. Copies of the selected calculations.
of specific items that will be reviewed during the onsite inspection  
    28. Copies of training documents that ensure that personnel are aware of gas-related
week. The inspector  
        concerns.
will select specific items from the information  
    29. Copies of corrective action program implementing procedures.
requested  
    30. Electronic copies of the current technical specifications, technical specification bases,
below and then request from your staff additional  
        final safety analysis report, and technical requirements manual.
documents  
                                              -3-                                         Enclosure
needed during the onsite inspection  
weeks. Also, we request that you categorize  
the documents  
in your response with the numbered list below. Please provide requested  
documentation  
electronically  
if possible.  
If requested  
documents  
are large and only hard copy formats are available, please inform the inspector(s), and provide subject documentation  
during the first day of the onsite inspection.  
If you have any questions  
regarding  
this information  
request, please call the inspector  
as soon as possible.  
I. Information  
Requested  
By August 1, 2011 1. List of corrective  
action program documents (with a short description)  
associated  
with Generic Letter (GL) 2008-01, voids in piping, and pressure transients  
for the previous three years. 2. List of changes (with a short description  
and tracking number) to the final safety analysis report (FSAR), technical  
specifications, technical  
specification  
bases, and technical  
requirements  
manual associated  
with the resolution  
of GL 2008-01. 3. List of calculations  
associated  
with GL 2008-01, including  
calculations  
that have been changed or created in response to GL 2008-01 (with a short description  
of the calculation  
and the change). 4. List (with a short description)  
of gas intrusion  
mechanisms  
that apply to the plant and the affected system locations (e.g. identify the source, conditions, and expected void locations).  
5. List of the suction piping sections identified  
as susceptible  
to gas accumulation (the list should identify the corresponding  
system). -1 -Enclosure
6. List of the discharge  
piping sections identified  
as susceptible  
to gas accumulation (the list should identify the corresponding  
system). 7. Copies of isometric  
drawings of the emergency  
core cooling, residual heat removal, and containment  
spray systems (hard-copies  
are preferred).  
8. Copies of piping and instrumentation  
diagrams (P&IDs) of the emergency  
core cooling, residual heat removal, and containment  
spray systems (hard-copies  
are preferred).  
9. Copies of program documents  
and procedures  
developed  
to implement  
the resolution  
of GL 2008-01. 10. List of actions that were completed  
in response to GL 2008-01. 11. Copies of the modification  
packages for hardware modifications  
as part of the resolution  
of GL 2008-01. 12. Design basis documents  
of the emergency  
core cooling, residual heat removal, and containment  
spray systems. 13. Design basis documents  
of keep-full  
systems of the emergency  
core cooling, residual heat removal, and containment  
spray systems. 14. System walkdown reports associated  
with the resolution  
of GL 2008-01. 15. If applicable, provide a list of inaccessible  
locations  
where plant walkdowns  
of the emergency  
core cooling, residual heat removal, and containment  
spray systems have not been completed.  
Include an explanation  
of why each area is considered  
inaccessible.  
16. Copies of surveillance  
procedures  
associated  
with the resolution  
of GL 2008-01 and the results of the last two surveillances  
for the emergency  
core cooling, residual heat removal, and containment  
spray systems. 17. Copies of procedures  
used for detecting  
and determining  
void volumes. 18. Copies of procedures  
used for filling and venting. 19. Copies of trends of periodic venting results. 20. Copies of the engineering  
evaluations  
performed  
for all identified  
voids in the past three years. 21. Basis for the void acceptance  
criteria (e.g. calculation).  
If applicable, provide the justification  
for any deviation  
from the void acceptance  
criteria established  
by the Office of Nuclear Reactor Regulation (NRR). 22. Copy of any void transport  
analyses. -2 -Enclosure
23. Copy of vortexing  
calculations  
associated  
with systems under the scope of GL 2008-01. 24. Copies of self-assessments  
associated  
with the implementation  
of the GL 2008-01 program. II. Information  
Requested  
By August 15,2011 25. Copies of the selected corrective  
action program documents.  
26. Copies of the selected licensing  
and design basis document changes. 27. Copies of the selected calculations.  
28. Copies of training documents  
that ensure that personnel  
are aware of gas-related  
concerns.  
29. Copies of corrective  
action program implementing  
procedures.  
30. Electronic copies  
of the current technical  
specifications, technical  
specification  
bases, final safety analysis report, and technical  
requirements  
manual. -3 -Enclosure
}}
}}

Latest revision as of 17:59, 12 November 2019

Notification of Inspection (NRC Inspection Report 05000445/2011004, 05000446/2011004) and Request for Information
ML11181A076
Person / Time
Site: Comanche Peak  Luminant icon.png
Issue date: 06/30/2011
From: Thomas Farnholtz
Region 4 Engineering Branch 1
To: Flores R
Luminant Generation Co
References
IR-11-004
Download: ML11181A076 (5)


See also: IR 05000445/2011004

Text

UNITED STATES

NUCLEAR REGULATORY COMMISSION

REGION IV

612 EAST LAMAR BLVD, SUITE 400

ARLINGTON, TEXAS 76011-4125

June 30, 2011

Rafael Flores, Senior Vice President

and Chief Nuclear Officer

Luminant Generation Company LLC

Comanche Peak Nuclear Power Plant

P.O. Box 1002

Glen Rose, TX 76043

SUBJECT: COMANCHE PEAK NUCLEAR POWER PLANT, UNITS 1 AND 2 -

NOTIFICATION OF INSPECTION (NRC INSPECTION REPORT

05000445/2011004; 05000446/2011004) AND REQUEST FOR INFORMATION

Dear Mr. Flores:

On August 15, 2011, the U.S. Nuclear Regulatory Commission (NRC) will begin the onsite

portion of the Gas Accumulation Management in Emergency Core Cooling, Decay Heat

Removal, and Containment Spray Systems Temporary Instruction at your Comanche Peak

Nuclear Power Plant, Units 1 and 2. This inspection will be performed in accordance with NRC

Temporary Instruction (TI) 2515/177.

Experience has shown that this inspection is resource intensive both for the NRC inspectors

and your staff. In order to minimize the impact to your onsite resources and to ensure a

productive inspection, we have enclosed a request for documents needed for this inspection.

The documents have been divided into two groups.

  • The first group lists information necessary for our initial inspection scoping and in-office

preparation activities. This information should be separated by information request number,

especially if provided electronically (e.g., folder with the information request number). This

information should be available to the inspector no later than August 1, 2011. Upon review of

these documents, the inspectors will select additional documentation for review upon arrival.

By August 10, 2011, the inspector will communicate the initial selected samples.

  • The second group of documents requested is needed to support our onsite inspection

activities. This set of documents should be available to the inspector on August 15, 2011. It

is also requested that corrective action documents and responses to questions developed

during the inspection be provided to the inspector as the documents are generated.

We have discussed the schedule for these inspection activities with your staff and understand

that our regulatory contact for this inspection will be Gary Merka of your licensing organization.

If there are any questions about this inspection or the materia! requested, please contact the

inspector, Matt Young, at 817-276-6545 or by email at '-'-==:.J:-==~=~='

-2-

This letter does not contain new or amended information collection requirements subject to the

Paperwork Reduction Act of 1995 (44 U.S.C. 3501 et seq.). Existing information collection

requirements were approved by the Office of Management and Budget, control number

3150-0011. The NRC may not conduct or sponsor, and a person is not required to respond to,

a request for information or an information collection requirement unless the requesting

document displays a currently valid Office of Management and Budget control number.

In accordance with Code of Federal Regulations, Title 10, Part 2.390 of the NRC's Rules of

Practice, a copy of this letter and its enclosure will be available electronically for public

inspection in the NRC Public Document Room or from the Publicly Available Records (PARS)

component of NRC's document system (ADAMS). ADAMS is accessible from the NRC Web

site at (the Public Electronic Reading Room).

Thomas R. Farnholtz, Chief

Engineering Branch 1

Division of Reactor Safety

Dockets: 50-445; 50-446

Licenses: NPF-87; NPF-89

Enclosure: Management of Gas Accumulation in Emergency Core Cooling, Decay Heat

Removal, and Containment Spray Systems Temporary Instruction Document Request

cc w/encl:

Distribution via ListServ for Comanche Peak

MANAGEMENT OF GAS ACCUMULATION IN EMERGENCY CORE COOLING, DECAY

HEAT REMOVAL, AND CONTAINMENT SPRAY SYSTEMS TEMPORARY INSTRUCTION

DOCUMENT REQUEST

inspection Report: 05000445/2011004; 05000446/2011004

On-site Inspection Dates: August 15-19, 2011

Inspection Procedure: TI 2515/177, "Management of Gas Accumulation in

Emergency Core Cooling, Decay Heat Removal, and

Containment Spray Systems"

Lead InspectorlTeam Leader: Matt Young

817 -276-6545

Matt.young@nrc.gov

The following information should be sent to the Region IV office in hard copy or electronic

format (ims.certrec.com or compact disc, preferred), in care of Matt Young, to facilitate the

selection of specific items that will be reviewed during the onsite inspection week. The

inspector will select specific items from the information requested below and then request from

your staff additional documents needed during the onsite inspection weeks. Also, we request

that you categorize the documents in your response with the numbered list below. Please

provide requested documentation electronically if possible. If requested documents are large

and only hard copy formats are available, please inform the inspector(s), and provide subject

documentation during the first day of the onsite inspection. If you have any questions regarding

this information request, please call the inspector as soon as possible.

I. Information Requested By August 1, 2011

1. List of corrective action program documents (with a short description) associated with

Generic Letter (GL) 2008-01, voids in piping, and pressure transients for the previous

three years.

2. List of changes (with a short description and tracking number) to the final safety analysis

report (FSAR), technical specifications, technical specification bases, and technical

requirements manual associated with the resolution of GL 2008-01.

3. List of calculations associated with GL 2008-01, including calculations that have been

changed or created in response to GL 2008-01 (with a short description of the

calculation and the change).

4. List (with a short description) of gas intrusion mechanisms that apply to the plant and the

affected system locations (e.g. identify the source, conditions, and expected void

locations).

5. List of the suction piping sections identified as susceptible to gas accumulation (the list

should identify the corresponding system).

- 1- Enclosure

6. List of the discharge piping sections identified as susceptible to gas accumulation (the

list should identify the corresponding system).

7. Copies of isometric drawings of the emergency core cooling, residual heat removal, and

containment spray systems (hard-copies are preferred).

8. Copies of piping and instrumentation diagrams (P&IDs) of the emergency core cooling,

residual heat removal, and containment spray systems (hard-copies are preferred).

9. Copies of program documents and procedures developed to implement the resolution of

GL 2008-01.

10. List of actions that were completed in response to GL 2008-01.

11. Copies of the modification packages for hardware modifications as part of the resolution

of GL 2008-01.

12. Design basis documents of the emergency core cooling, residual heat removal, and

containment spray systems.

13. Design basis documents of keep-full systems of the emergency core cooling, residual

heat removal, and containment spray systems.

14. System walkdown reports associated with the resolution of GL 2008-01.

15. If applicable, provide a list of inaccessible locations where plant walkdowns of the

emergency core cooling, residual heat removal, and containment spray systems have

not been completed. Include an explanation of why each area is considered

inaccessible.

16. Copies of surveillance procedures associated with the resolution of GL 2008-01 and the

results of the last two surveillances for the emergency core cooling, residual heat

removal, and containment spray systems.

17. Copies of procedures used for detecting and determining void volumes.

18. Copies of procedures used for filling and venting.

19. Copies of trends of periodic venting results.

20. Copies of the engineering evaluations performed for all identified voids in the past three

years.

21. Basis for the void acceptance criteria (e.g. calculation). If applicable, provide the

justification for any deviation from the void acceptance criteria established by the Office

of Nuclear Reactor Regulation (NRR).

22. Copy of any void transport analyses.

-2- Enclosure

23. Copy of vortexing calculations associated with systems under the scope of GL 2008-01.

24. Copies of self-assessments associated with the implementation of the GL 2008-01

program.

II. Information Requested By August 15,2011

25. Copies of the selected corrective action program documents.

26. Copies of the selected licensing and design basis document changes.

27. Copies of the selected calculations.

28. Copies of training documents that ensure that personnel are aware of gas-related

concerns.

29. Copies of corrective action program implementing procedures.

30. Electronic copies of the current technical specifications, technical specification bases,

final safety analysis report, and technical requirements manual.

-3- Enclosure