Browse wiki
Jump to navigation
Jump to search
ML032720538 +
10 CFR 50 Appendix A +, 10 CFR 50.46 +, 10 CFR 50.48 +, 10 CFR 100 +, 10 CFR 50 +, 10 CFR 50.63 +, 10 CFR 51 +, 10 CFR 50.49 +, 10 CFR 50.61 +, 10 CFR 50.62 +, 10 CFR 50 Appendix G +, 10 CFR 50 Appendix H +, 10 CFR 100.11 +, 10 CFR 50.55a +, 10 CFR 50.46#b1 +, 10 CFR 50.46#b +, 10 CFR 50.46#b5 +, 10 CFR 50.46#b2 +, 10 CFR 50.46#b3 + and 10 CFR 50.46#b4 +
ML032731029 + and ML032730666 +
GDC 20 +, GDC 38 +, GDC 15 +, GDC 50 +, GDC 16 +, GDC 10 +, GDC 12 +, GDC 55 +, GDC 35 +, GDC 14 +, GDC 11 +, GDC 13 +, GDC 31 +, GDC 25 +, GDC 28 +, GDC 27 +, GDC 17, Electric power systems +, GDC 2, Design bases for protection against natural phenomena +, GDC 19, Control room +, GDC 4, Environmental and dynamic effects design bases +, GDC 1, Quality standards and records +, GDC 3, Fire protection + and GDC 26, Reactivity control system redundancy and capability +
NRC Generic Letter 84-04, Safety Evaluation of Westinghouse Topical Reports Dealing with Elimination of Postulated Pipe Breaks in PWR Primary Main Loops (Generic Letter 84-04) +, NRC Generic Letter 89-08, Erosion/Corrosion-Induced Pipe Wall Thinning +, NRC Generic Letter 96-06, Assurance of Equipment Operability and Containment Integrity During Design-Basis Accident Conditions +, NRC Generic Letter 96-05, Periodic Verification of Design-Basis Capability of Safety-Related Motor-Operated Valves +, NRC Generic Letter 89-10, Safety-Related Motor-Operated Valve Testing and Surveillance + and NRC Generic Letter 95-07, Pressure Locking and Thermal Binding of Safety-Related Power-Operated Gate Valves +
Has query"Has query" is a predefined property that represents meta information (in form of a <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Subobject">subobject</a>) about individual queries and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
ML032720538 +, ML032720538 +, ML032720538 +, ML032720538 +, ML032720538 +, ML032720538 +, ML032720538 +, ML032720538 +, ML032720538 +, ML032720538 +, ML032720538 +, ML032720538 +, ML032720538 +, ML032720538 +, ML032720538 +, ML032720538 +, ML032720538 +, ML032720538 +, ML032720538 +, ML032720538 +, ML032720538 +, ML032720538 +, ML032720538 +, ML032720538 +, ML032720538 +, ML032720538 +, ML032720538 +, ML032720538 +, ML032720538 +, ML032720538 +...
3.472222e-5 d (8.333333e-4 hours, 4.960317e-6 weeks, 1.1415e-6 months) +, 2.777778e-4 d (0.00667 hours, 3.968254e-5 weeks, 9.132e-6 months) +, 1.157407e-5 d (2.777778e-4 hours, 1.653439e-6 weeks, 3.805e-7 months) +, 4.62963e-5 d (0.00111 hours, 6.613757e-6 weeks, 1.522e-6 months) +, 0.00116 d (0.0278 hours, 1.653439e-4 weeks, 3.805e-5 months) + and 8.333333e-4 d (0.02 hours, 1.190476e-4 weeks, 2.7396e-5 months) +
September 29, 2003 +
Modification date"Modification date" is a predefined property that corresponds to the date of the last modification of a subject and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
12:38:49, 16 January 2025 +
NUREG-1269 +, NUREG-0852, Sser Supporting Vendor Responses to Confirmatory Issue 2, Steam Generator Tube Rupture. Calculated Radiological Consequences of Postulated Steam Generator Tube Rupture Accident Meets 10CFR100.11 Dose Ref Values + and NUREG-0588, Responds to 870709 Request for NRR Assistance in Determining Adequacy of Two Test Repts Re Acceptance Criteria of NUREG-0588,Category I.Qualification of Kulka Terminal Blocks Demonstrated & Not Used in Instrumentation Circuits +
121 +
Processing error"Processing error" is a predefined property provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a> and represents errors that appeared in connection with improper value annotations or input processing.
Approval +
September 29, 2003 +
Steam Generator +, Reactor Coolant System +, Feedwater +, Reactor Protection System +, Emergency Diesel Generator +, Main Steam Isolation Valve +, Auxiliary Feedwater +, Primary containment +, Main Transformer +, Main Turbine +, Shutdown Cooling +, Safety Parameter Display System +, HVAC +, Reactor Pressure Vessel +, Residual Heat Removal +, Steam Bypass Control System +, Fuel Pool Cooling and Cleanup +, Circulating Water System +, Main Steam Safety Valve +, Qualified Safety Parameter Display System +, Spray Pond +, Emergency Core Cooling System +, Decay Heat Removal +, Main Steam Line +, Main Condenser +, Control Rod +, Main Steam + and Containment Spray +
9/29/03 - Palo Verde Nuclelar Generating Station, Unit 2 (PVNGS-2) Issuance of Amendment 149 on Replacement of Steam Generators and Uprated Power Operations (Tac. MB3696) +
Safe Shutdown +, Boric Acid +, Shutdown Margin +, Ultimate heat sink +, Fire Barrier +, Stroke time +, Anticipated operational occurrence +, Tornado Missile +, Safe Shutdown Earthquake +, Probabilistic Risk Assessment +, High Energy Line Break +, Flow Accelerated Corrosion +, Intergranular Stress Corrosion Cracking +, Stress corrosion cracking +, Loss of Offsite Power +, Exemption Request +, Earthquake +, Power-Operated Valves +, Fuel cladding +, Pressure Boundary Leakage +, Pressure boundary leak +, Offsite Circuit +, Fire Protection Program +, Power change +, Coast down +, Power Uprate +, Overspeed +, Loss of condenser vacuum +, Water hammer +, Control Room Habitability +...
URL"URL" is a <a href="/Special:Types/URL" title="Special:Types/URL">type</a> and predefined property provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a> to represent URI/URL values.