ML20132C07513 December 1996Part 21 Rept Re Testing of Six HFD3045 & HFD3060 Molded Case Circuit Breakers w/125 Volt DC Shunt Trip Devices.Identified Incorrectly Installed DC Shunt Trip Units & Are in Process of Being Returned to Vendor
ML20112G3874 June 1996Potential Part 21 Rept Re Capscrews W/Trace Code of K7 Mfg by Cardinal Industries (Now Known as Accutech) & Distributed by Energy & Process Corp for Plant CP S/N 0194012.Pump/motor Would Remain Operational Throughout Worse Case Scenario
ML20126J59631 December 1992Part 21 Rept Re Potential Loss of RHR Cooling During Nozzle Dam Removal.Nozzle Dams May Create Trapped Air Column Behind Cold Leg Nozzle Dam.Mod to Nozzle Dams Currently Underway. Ltrs to Affected Utils EnclHydrostatic
ML20125C7167 December 1992Part 21 Rept Re Possibility for Malfunction of Declutching Mechanisms in SMB/SB-000 & SMB/SB/SBD-00 Actuators. Malfunction Only Occurs During Seismic Event.Balanced Levers May Be Purchased from Vendor.List of Affected Utils EnclStroke time
Anchor Darling
ML20127P58623 November 1992Followup to 921005 Part 21 Rept Re Potential Defect in SB/SBD-1 Housing Cover Screws.Procedure Re Replacement of SBD-1 Spring Cover Bolts Encl.All Fasteners Should Be Loosened & Removed.List of Affected Utils Encl
ML20086G29321 November 1991Part 21 Rept Re Failure of Model 763 & 763A Static Pressure Transmitters.Caused by Short Circuit in Connector Pin to Adjacent Mounting Screw.Engineering Drawings & Mfg Work Instructions Changed & Stock Purged of Subj Transmitters
ML20070A68617 January 1991Part 21 Rept Re Failure of 4.16 Kv vertical-lift Switchgear Cell Mounted,Auxiliary Contacts to Operate on Demand During Testing of Auxiliary Standby Switchgear at Facility. Initially Reported on 901101.New Test Link Sent to Facility
ML20062D9351 November 1990Part 21 Rept Re Failure of 4.16 Kv Vertical Lift Switchgear, cell-mounted Auxiliary Contacts to Operate on Command During Testing of Standby Switchgear at Plant.Caused When Maladjusted Test Link Inserted Between Breaker & Switch
ML20059N51916 October 1990Part 21 Rept Re Rod & Bearing Assembly Failures Noted by Wolf Creek Nuclear Operating Corp During Testing.Rept Will Be Issued Outlining Root Cause & Corrective Actions to Prevent Recurrence
ML17223A74526 January 1990Part 21 Rept Re Backup Rings Furnished in Spare Parts Seal Kits & in 25 Gpm 4 Way Valves as Part of Actuators Made of Incorrect Matl.Rings Should Be Viton & Have Been Identified as Buna N
ML20246J06329 August 1989Part 21 Rept Re Namco Refusal to Certify Design & Matls for Replacement Namco Limit Switches Supplied by Masoneilan. Initially Reported on 890825.Switches Put on QC Hold Until Final Disposition of Switches Determined
ML20244D2901 June 1989Part 21 Rept Re Buchanan 724 Terminal Blocks Supplied by Limitorque Corp,Rather than Correct Buchanan 524 Terminal Blocks.Caused by Error in Order Processing.Training Held to Ensure That Procedures Followed Correctly
ML20246N79110 May 1989Part 21 Rept Re Room Cooler Vents & Drains Mfg by Carrier Corp Per Bechtel Specs,W/Galvanic Corrosion at Interface w/90-10 copper-nickel Room Cooler Supply & Return Headers. Vents & Drains Will Be Modified During Current Outage
ML20235Y4813 March 1989Part 21 Rept Re Cracked Welds Discovered on Striker Plates of GE Circuit Breakers.Initially Reported on 890130.GE Advised Util That Striker Plates Subj to Impact Loading Only When Breaker in Racked Out & Operated in Test Position
ML20195F61918 November 1988Part 21 Rept Re GE Magne-Blast Circuit Breakers.Initially Reported on 881116.Welds on All safety-related Breakers Will Be Repaired Prior to Entry Into Hot ShutdownOvertravel
ML20151W78416 August 1988Part 21 Rept Re Cracking of Slides Used in Four Way Valves Furnished on Actuators for MSIVs Due to Brazing/Heat Treating of Slide Matl.All Sites Using Actuators Will Be Formally Notified by 880826.List Encl
ML20151B4291 April 1988Part 21 Rept Re Inconsistencies in Gould,Inc Certificate of Compliance Received W/Class 1E Fuses Procured from Planned Maint Sys Due to Fuses Not Being Qualified for Certain Specs.Initially Reported on 880329.Fuses Remain on Hold
ML20234C73523 June 1987Supplemental Part 21 Rept Re Silicone Foam Seal Anomolies at Wolf Creek Generating StationFire Watch
ML20211P72123 February 1987Part 21 Rept Re Rockbestos Coaxial Cable Used in Sorrento Electronics Digital & Analog high-range Radiation Monitor. Insulation Resistance at High Temp Not High Enough for Ion Chamber & Associated Electronics to Operate Properly
ML20153D88617 February 1986Part 21 Rept Re Failure of Penetration & Conduit Seal Configurations During Fire Tests.Initially Reported on 860214.Evaluation of Number & Location of Defective Seals in Progress.Nrc Assistance RequestedFire Barrier
ML20151Y8144 February 1986Part 21 Rept Re Colt-Pielstick Engine Tripping Out on High Speed When Started for Test Purposes at Seabrook.Caused by Source of Air Pressure Staying On.Engines Will Be Modified to Positively Vent Air from Rack Boost CylinderSafe Shutdown
Boric Acid
Shutdown Margin
Packing leak
High Radiation Area
Ultimate heat sink
Fire Barrier
Anticipated operational occurrence
Hydrostatic
Probabilistic Risk Assessment
Operating Basis Earthquake
Design basis earthquake
Process Control Program
Stress corrosion cracking
Fuel cladding
Pressure Boundary Leakage
Grace period
Power change
Unidentified leakage
Overspeed trip
Eddy-Current Testing
Operational leakage
ML20137W26130 September 1985Update to Part 21 Rept Re Insp for Cracked Welds Discovered in Generator Brackets.Insp for Callaway Unit 1 Postponed Until Next Refueling Outage (Probably Apr 1986).No Cracks Discovered During Insp at Wolf Creek
ML20135E1165 September 1985Part 21 Rept Re Use of Connectron non-IEEE Qualified Matl in Spare Part Terminal Blocks Supplied to Facilities. Appropriate Customers Notified.Terminal Blocks Should Be Reviewed to Identify Defective Matl
ML20135G06528 August 1985Supplemental Part 21 & Deficiency Rept U-70 Re Failures of Crane-Deming Keepwarm Lube Oil Pumps.Initially Reported on 840328.Permanent ASME Section III Equivalent Pumps Will Be Installed on Engine Skid by First Refueling
ML20135D44815 August 1985Part 21 Rept Re Raychem auto-trace 20PTV1 self-regulating Electric Heat Tracers & Associated Derivatives.Licensees Advised of Problem & Procedures to Determine Any Effect on Operation
ML20210G99213 August 1985Part 21 Rept Re Failure of Isolated Worm Shaft Gear When Certain Critical Speeds Combined W/Repetitive Transfer of Actuator Clutch Mechanism from Manual (Handwheel) to Motor Drive Mode.Two Possible Solutions Noted
ML20129J73824 June 1985Part 21 Rept Re Auto-Trace 20PTV1,self-regulating Electric Heat Trace,W/Lower than Specified Power Output.Deficiency Could Result in Lower Maint Temp in Electric Pipe Heating Sys.Affected Licensees Identified
ML20117B8141 May 1985Part 21 Rept Re Ruskin Fire Dampers Installed at Facility. Initially Reported on 850426.Fire Dampers Found in Discrepant Condition Will Be Reworked in Order to Assure Integrity & Proper Functioning
ML20116E84823 April 1985Part 21 Rept Forwarding Rev 1 to Insp Procedure for Investigating Emergency Diesel Generators for Fractured Welds on Air Deflectors.Rev Will Be Forwarded to Each Facility
ML20116D32022 April 1985Part 21 Rept Re Ruskin Mfg Co Welds Used to Join Damper to Damper & Damper Section to Mullion Plates.Welds Not in Accordance W/Approved Design Drawings.Drawing 5415 Revised to Indicate Weld Spacing.Drawing of Weld Spacing Encl
ML20115J13615 April 1985Forwards Insp Procedure for Investigating Emergency Diesel Generators for Fractured or Cracked Welds to Determine If Part 21 Problem Exists,Per Jg Borman
ML20100E06529 March 1985Part 21 Rept Re Series of Cracked Welds Discovered in Generators.Welds Occurred in Conical Baffle Section of Coil Guards.All Units Will Be Inspected.Affected Plants Listed
NRC-85-3024, Part 21 Rept Re Possible Undetectable Failures in ESF Actuation Sys.Initially Reported on 791107.Possibility of Undetectable Failures Remain Under Certain Circumstances Despite Change in Hardware22 March 1985Part 21 Rept Re Possible Undetectable Failures in ESF Actuation Sys.Initially Reported on 791107.Possibility of Undetectable Failures Remain Under Certain Circumstances Despite Change in Hardware
ML20102B95313 February 1985Supplemental Final Deficiency Rept (53564-K159) Re Concrete Coatings Inside Containment.Initially Reported on 841213. Coated Concrete Surfaces Inside Containment Will Perform Satisfactorily Under DBA ConditionsCoatings
ML20107B6937 February 1985Final Deficiency Rept (53564-K161) Re Uncertainties in Resistance Temp Detectors Calibr.Westinghouse Evaluation Demonstrated That Revised Resistance Temp Detectors Uncertainty Acceptable
ML20101T12125 January 1985Final Deficiency Rept (53564-K159) Re Concrete Coatings Inside Containment.Initially Reported on 841213.Destructive Adhesion Tests Performed on Locations Selected by Sampling Plan to Verify Acceptability of CoatingsCoatings
ML20104B14718 January 1985Final Deficiency Rept Re Insp of Structural Steel Welds. Initially Reported on 840918.Structural Concerns Identified & Corrective Action Repts Issued to Have Shims Less than 1/4 Inch Thick Placed Flush W/Mounting Frame
ML20114C79813 January 1985Final Deficiency Rept Re Removal & Replacement of ASME Components in Support of Cleaning & Flushing Activities. Initially Reported on 840711.Investigation Into Handling & Storage of ASME Components Removed from Sys Conducted
ML20104A81713 January 1985Final Deficiency Rept Re Subcooling Core Monitor Alarm & Caution Relays.Initially Reported on 840821.Interposing Relays & Diodes Added to Sys to Minimize Potential for & Suppress Effects of Any Arcs Generated
ML20104A86713 January 1985Final Deficiency Rept Re Standby Diesel Generator B Left Bank Turbocharger.Initially Reported on 840504.Caused by Loose Lock Nut on Left Bank Turbocharger Lubricating Oil Pump Centrifuge.Damaged Turbocharger Repaired & Inspected
ML20104B92413 January 1985Final Deficiency Rept Re Water Damaged Limitorque Motor Operators.Initially Reported on 840203.Caused by Leakage During Sys Flushing & Hydrostatic Testing Activities.Seals Added Inside Conduit & T-drains Installed in OperatorHydrostatic
ML20114C91413 January 1985Final Deficiency Rept (53546-K158) Re ASME Hangers & Component Supports.Initially Reported on 841212.Insulation Contractors Revised Procedures & Retrained Personnel to Preclude Further Tampering of Supports
ML20114C84413 January 1985Final Deficiency Rept Re Microbiologically Induced Corrosion in Hxs.Initially Reported on 840601.All HXs Utilizing Lake Water for Cooling Medium Eddy Current Inspected for Microbiologically Induced CorrosionHydrostatic
ML20114D10813 January 1985Final Deficiency Rept (53564-K118) Re safety-related Field Procurement by Constructor.Initially Reported on 840103. Complete Review of Constructor safety-related Purchase Orders Completed.All Nonconformance Repts Resolved
ML20113A42911 January 1985Part 21 Rept Re Incorrect Insulating Tape.Instructions Governing Handling of Incoming Matls Fully Adequate & If Followed,Would Have Prevented Error
ML20112D8064 January 1985Final Deficiency Rept Re MSIV Lockwashers.Initially Reported on 841207.Lockwashers Installed Via Startup Field Rept I-SU-122 & Will Be Completed Prior to Fuel Load
ML20112F5423 January 1985Forwards Dec 1984 Status Rept Re 10CFR50.55(e)/Part 21 Open Items
RBG-19-803, Final Deficiency Rept DR-234 Re Short Cap Screws,Shallow Bolt Holes,Damaged Dowel Pins & Damaged or Missing Lock Devices for Hanger Block Bolts in Check Valves Supplied by Velan Engineering,Ltd.Initially Reported on 84112828 December 1984Final Deficiency Rept DR-234 Re Short Cap Screws,Shallow Bolt Holes,Damaged Dowel Pins & Damaged or Missing Lock Devices for Hanger Block Bolts in Check Valves Supplied by Velan Engineering,Ltd.Initially Reported on 841128
ML20101L3597 December 1984Final Deficiency Rept Re Lubricating Oil Piping Sys for Safety Injection Pumps & Centrifugal Charging Pumps. Initially Reported on 840717.Replacement of safety-related Equipment W/O QA Program Will Be Repeated Per QA Program
ML20101L5637 December 1984Supplemental Final Deficiency Rept Re Installation of 3-h Rated Hollow Metal Fire Door Frames.Initially Reported on 840525.Existing Caulking Replaced W/Approved Flame Retardant Adhesive SealantSafe Shutdown