February 1, 2022 NRC 2022-0005 10 CFR 50.55a U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555 Point Beach Nuclear Plant, Unit 2 Docket 50-301 Renewed License No. DPR-27 Refueling Outage U2R38 Owner's Activity Report for Class 1, 2, 3 and MC ISi Examinations NextEra Energy Point Beach, LLC (NextEra) is submitting inservice inspection summary reports for inspections conducted prior to and during the Point Beach Nuclear Plant (PBNP) refueling outage U2R38 that concluded on Nov. 3, 2021. The enclosed report is submitted pursuant to the requirements of Subarticle IWA-6240 of Section XI of the American Society of Mechanical Engineers (ASME) Boiler and Pressure Vessel Code and ASME Code Case N-532-5.

The Enclosure to this letter contains the summary report, Form OAR-1, "Owner's Activity Report" for inservice inspections for Class 1, 2, 3 and MC components. The report is for the second outage of the third period of the fifth ten-year interval for Class 1, 2, 3 systems and the second outage of the second period of the third ten-year interval for MC components at PBNP Unit 2.

Sincerely, NextEra Energy Point Beach, LLC Eric Schultz Licensing Manager Enclosure cc: Administrator, Region Ill, USNRC Project Manager, Point Beach Nuclear Plant, USNRC Resident Inspector, Point Beach Nuclear Plant, USNRC PSCW Kim Schmitt, DSPS Boilers, State of Wisconsin NextEra Energy Point Beach, LLC 6610 Nuclear Road, Two Rivers, WI 54241

ENCLOSURE NEXTERA ENERGY POINT BEACH, LLC POINT BEACH NUCLEAR PLANT, UNIT 2 OAR-1, OWNER'S ACTIVITY REPORT FOR INSERVICE INSPECTION, FOR CLASS 1, 2, 3 AND MC COMPONENTS

\

3 pages follow

Page 1of3 FORM OAR-1 OWNER'S ACTIVITY REPORT Report Number: ISl-PB-U2R38-2021 Plant: NextEra Energy Point Beach Nuclear Plant 6610 Nuclear Road Two Rivers, Wisconsin 54241 Commercial Service Date: October 1, 1972 Refueling Outage No.: U2R38 Current Inspection Interval: ISi-Fifth Interval. IWE-Third Interval Current Inspection Period: ISi - Second Outage Third Period, IWE - Second Outage Second Period Edition and Addenda of Section XI applicable to the Inspection plan: ISi Fifth Interval and IWE Third Interval - 2007 Edition through 2008 Addenda Date and Revision of inspection plan: ISi - Fifth Interval November 15. 2017 Rev. 15 IWE- March 13. 2017. Rev. 1 Edition and Addenda of Section XI applicable to repairs and replacements, If different than the inspection plan: Same Code Cases Used: N-513-4. N-532-5, N-695-1, N-696-1. N-706-1, N-716-1, N-722-1, N-731, N-770-5, N-798, N-800, N-854.

CERTIFICATE OF CONFORMANCE I certify that (a) the statements made in this report are correct; (b) the examinations and tests meet the Inspection Plan as required by the ASME Code,Section XI; and (c) the repair/replacement activities and evaluations supporting the completion of U2R38 conform to the requirements of Section XI.

Signed &&o~~L '.l!<o<K.c &

Owner G.:0 µ._,.

DWSDeSignee, Title 811\.fill\4Wt"'1-'

Date f'r'otrr-t.1

'/,t. / zou..

~"'"

CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and employed by Hartford Steam Boiler Inspection and Insurance Company of Connecticut have inspected the items described in this Owner's Activity Report, and state that, to the best of my knowledge and belief, the Owner has performed all activities represented by this report in accordance with the requirements of Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the repair/replacement activities and evaluation described in this report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.

,AlB /Jb1t A1vf I,)~ f<.. uJI%J.1~

(National Board Number and Enflorsements)

EN-AA-203-1100-F01, REVISION 4 ECFORM-130

Page 2of3 FORM OAR-1 OWNER'S ACTIVITY REPORT TABLE 1 ITEMS WITH FLAWS OR RELEVANT CONDITIONS THAT REQUIRED EVALUATION FOR CONTINUED SERVICE Examination Category and Item Description Evaluation Description Item Number Missing support Item.

Revised calculation concluded that the as-found condition remains capable of meeting the design Rigid Support code of record requirements for the piping and the F-A/ F1.20A EB-9-R13 support. The as-found condition remains fully capable of performing its design safety functions.

No scope expansion or successive examinations required.

EN-AA-203-1100-F01, REVISION 4 ECFORM-130

Page 3 of 3 FORM OAR-1 OWNER'S ACTIVITY REPORT TABLE 2 ABSTRACT REPAIR/REPLACEMENT ACTIVITIES REQUIRED FOR CONTINUED SERVICE Repair/

Code Date Item Description Description of Work Replacement Class Completed Plan Number Repair of pitted surface found to be below 3 Heat Exchanger 05/13/2020 2020-019 minimum wall thickness requirements.

Replacement of piping section with through-wall 2 Piping 11/9/2021 2021-008-01 leak.

Replacement of flexible hose assembly with 3 Piping 11/9/2021 2021-044 through-wall leak.

EN-AA-203-1100-F01, REVISION 4 ECFORM-130