I -~ t Su NMC Committed to NuclearExcelnce Point Beach Nuclear Plant Operated by Nuclear Management Company, LLC February 22, 2006 NRC 2006-0019 10 CFR 50.55a U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555 Point Beach Nuclear Plant, Unit 1 Docket 50-266 License No. DPR-24 Filing of Owner's Inservice Inspection Summary Report for Point Beach Nuclear Plant Refueling Outage U1R29 In accordance with 10 CFR 50.55a, Nuclear Management Company, LLC (NMC), is submitting Inservice Inspection Summar/ Reports for inspections conducted prior to and during the Point Beach Nuclear Plant (PBNP) refueling outage Ul R29 that concluded on November 24, 2005. The enclosed Class 1,2, and 3 report is submitted pursuant to the requirements of subarticle IWA-6240 of the 1998 Edition with addenda through 2000 of Section Xi of the American Society of Mechanical Engineers (ASME) Boiler and Pressure Vessel Code. The IWE Class MC and IWL Class CC reports are submitted pursuant to the requirements of subarticle IWA-6240 of the 1992 Edition with addenda through 1992 of ASME Section Xl. to this letter contains the summary report, which includes Form OAR-1, the Owner's Activity Report for Inservice Inspections, for the Class 1,2, and 3 components.

The report includes the first outage of the second period of the fourth ten-year interval for Class 1, 2, and 3 systems. contains a separate Form OAR-1 for Class MC and CC components. The report includes the second outage of the third period of the first ten-year interval for Class MC and CC at PBNP Unit 1.

This letter contains no new commitments and no revisions to existing commitments.

Dennis L. Koehl Site Vice-President, Point Beach Nuclear Plant Nuclear Management Company, LLC Enclosures (2) t( I 6610 Nuclear Road

  • Two Rivers, Wisconsin 54241-9516 Telephone: 920.755.2321

Document Control Desk Page 2 cc: Administrator, Region 111, USNRC Project Manager, Point Beach Nuclear Plant, USNRC Resident Inspector, Point Beach Nuclear Plant, USNRC PSCW Mike Verhagen, State of Wisconsin

ENCLOSURE I OAR-1, OWNER'S ACTIVITY REPORT FOR INSERVICE INSPECTION, FOR CLASS 1, 2, AND 3 COMPONENTS 5 pages follow

FORM OAR-I OWNER'S ACTIVITY REPORT Report Number Ul R29 Outage Class 1. 2. and 3 IS! Examinaticn Ownpr Nuce1pr Mannamement Cnmnnn 700 First Streett Hiudsnn Wkcnnsin 4016 (Name and Address of Owner)

Plant Point Beach Nuclear Plant. 6590 Nuclear Road. Two Rivers, Wisconsin 54241 (Name and Address of Plant)

Unit No. li Commercial Service Date December 21. 1970 Refueling Outage No. U I R29 (If applicable)

Current Inspection Interval Fourth (Ist, 2nd, 3rd, 4th, other)

Current Inspection Period (Ist, 2nd, 3rd)

Edition and Addenda of Section Xl applicable to the inspection plan 1998 Edition 2000 Addenda Date and Revision of inspection plan October 18. 2005 / Revision 4 Edition and Addenda of Section XI applicable to repairs and replacements, if different than the inspection plan Same CERTIFICATE OF CONFORMANCE I certify that the statements made in the Owner's Activity Report are correct, and that the examinations, tests, repairs, replacements, evaluations, and corrective measures represented by this report conform to the requirements of Section Xl.

Certificate of Authorization No. N/A Expiration Date N/A (If a icable) ..

Signed 7 y -g - H -- ,~

i-- ISI Coordinator Date ;2 f He 00CR 6_

Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION 1,the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Wisconsin and employed by HSBCT of Hartford, Connecticut have inspected the items described in this Owner's Activity Report, during the period June 9, 2004 to November 24,2005, and state that to the best of my knowledge and belief, the Owner has performed all activities represented by this report in accordance with the requirements of Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations, tests, repairs, replacements, evaluations, and corrective measures describe] in this report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal inju r property damage or loss of any kind arising from the connected with this inspection.

Commissions WI 247972

/ flis' t6r's Signature National Board, State, Province, and Endorsements Date I 1 W10

f Table 1 Abstract of Examinations and Tests Total Total Total Total Examinations Examinations Examinations Examinations Credited (%) to Examination Required for Credited for this Credited (%) Date for the Category the Interval Period for the Period Interval Remarks B-A 7 0 0 7 Deferral permissible, number of welds reduced by one from previous submittal due to head replacement during UIR29, which removed one weld from count B-B 7 3 43 71 B-D 25 8 _ 32 __ 52 B-F ,__ ___ ___ Part of Risk-Informed ISI Program, see Examination Category R-A B-G-I6 2 = 33 = 67 B-G-2 1_5 3 20 47 B-J - -- Part of Risk-Informed ISI Program! see Examination Category R-A B-K 8 0 0 25 B-L-I 0 0 Deferred to the end of the interval B-L-2 I _0_0 0 Examined only if disassembled for maintenance, repair, or volumetric examination B-M-I I_ 0 0 Scheduled for the third period B-M___-2 see remarks . 0 0 Examined only if disassembled for maintenance, repair, or volumetric examination B-N-I 3 1 33 67 Accessible portions of the vessel internal surface each period B-N-2 4 0 0 0 Deferred to the erd of the interval B-N-3 I 0 0 0 Deferred to the erd of the interval B-O 2 0 New welds installed due to RPV head replacement, 100% of CRD's were examined for preservice B-P 8 1 33 38 Pressure tests. See notes 2 and 4.

B-______________ Steam Generator tubing is examined in accordance with plant Technical Specifications C-A 9 2 22 44 C-B 18 6 33 67 C-C 13 0 0 23 C-D -- --- -- - There are no class 2 bolts greater than 2" at PBNP C-F-I -_ _ Part of Risk-Informed ISI Program, see Examination Category R-A C-F-2 -- - -- Part of Risk-Informed ISI Program, see Examination Category R-A C-G I 0 0 0 Scheduled for the third period C-H 50 6 35 42 Pressure tests. See notes 3 and 4.

D-A 8 0 0 50 D-B 21 2 29 43 Pressure tests. See notes 3 and 4.

F-A 134 9 7 50 R-A 133 21 16 42 Includes class I and 2 piping welds I1. All percentages are rounded to the nearest 1%.

2. Pressure tests are conducted each outage with one extra test performed during the third period.
3. Pressure tests are conducted once each period, so each test wlI normally be conducted three times over the interval. The exception is in the Component Cooling system, which was split into two tests during the second period, resulting in five tests instead of six tests.

4 For pressure tests, the total number of test per period are calculated by taking the number of tests completed for the period divided by the number required for the period.

5. Limited examinations will be submitted to the NRC for reliefin accordance with 10 CFR 50.55a.

Table 2 Items with Flaws or Relevant Conditions that Required Evaluation for Continued Service Flaw or Relevant Condition Flaw Characterization Found During Scheduled Examination Section XI Examination or Test Category Item No. Item Description (IWA-3300) (Yes or No)

F-A Fl.lOB ISI-878B-3 N/A Yes F-A F1.40A RPV Support N/A Yes F-A Fl.lOC RC-2501R-2-RC14 N/A Yes R-A R1.20 RC-04-PR-1001-05 IWA-3310 No R-A R1.20 RC-04-PS-1001-03 IWA-3310 No R-A R1.20 RC-04-PS-1001-04 IWA-3310 No R-A R1.20 RC-03-PSF-1002-03 IWA-3310 No C-A Cl.1O SG-B-4 IWA-3320 Yes B-B B2.11 PZR-Cweld-l IWA-3320 Yes C-A Cl.1O SG-A-4 IWA-3320 No F-A F1.lOC RC-2501R-14-H204 N/A Yes F-A Fl.1OS HS-19 N/A No F-A Fl.lOS HS-20 N/A No F-A Fl.lOS HS-13 N/A No F-A Fl.IOS lHS-2 N/A No F-A Fl.IOS lHS-8 N/A No F-A F1.20C EB-9-19 N/A No

Table 3 Abstract of Repairs, Replacements, or Corrective Measures Required for Continued Service Flaw or Relevant Condition Found During Repair, Replacement, Scheduled Section XI Repair/

Code or Corrective Examination or Test Date Replacement Class Measure Item Description Description of Work (Yes or No) Coinleted Plan Number 3 Replacement IHX-055A-1 Replace end bell No 4/19/2005 2005-0013 3 Replacement SW-315 Replace valve No 9/8/2005 2005-0015 3 Replacement DA-100 Replace valve No 4/21/2005 2005-0020 3 Replacement HX-055A-1 Replace end bell No 11/9/2005 2005-0024 3 Replacement HX-055A-2 Replace end bell No 11/9/2005 2005-0025 3 Replacement Piping HB-19 Replacement of piping due No 9/21/2005 2005-0026 lyt onrccivc Mcas 1VkH.,Y-U13Bik1VIJ V l 2D J

+-U- ....

U 1A_ Q/,2flAAn 1)AnAz~nnj I Plurs111 U y8 iI /3!200 5 _____________

Modify support to be in 2 Corrective Measure PS EB-09-19 compliance IEB 79-14 No 1/31/2006 2005-0037 requirements 3 Replacement DA-100 Replace valve No 2/2/2006 2005-0040 I Replacement RH-V-09 Replace valve due to No 12/23/2005 2005-0042

_________ ~~~~leakage _ _ _ _ _ _ _ _ _ _ _

1 Replacement 1R-1 Replace RPV head No 12/23/2005 2005-0051 Replacement of valve due 3 Replacement SW-360 to erosion/improper weld No 2/1/2006 2005-0056 repair Replacement of valve due 3 Replacement SW-322 to erosion/improper weld No 1/3/2006 2005-0057 repair weld buildup of flange 2 Repair Piping EB-01-SP nozzle and re-machining No 12/21/2005 2005-0064 due to damage 2 Replacement IAF-100 Replace due to damage No 12/1/2005 2005-0068

_ _ _ __ __ _ __ __ _ __ _ _ _ _ _ _ _ _during rem oval _ _ _ _ _ _ _ _ _ _ _ _ _ I__ _ _ _ _ _ _

Flaw or Relevant Condition Found During Repair, Replacement, Scheduled Section XI Repair/

Code or Corrective Examination or Test Date Replacement Class Measure Item Description Description of Work (Yes or No) Completed Plan Number Flap indications until 1 Corrective Measure Pipe RC 2501R-01 removed or reduced to an Yes 10/25/2005 2005-0070 acceptable size 3 Corrective measure SW-360 Weld buildup of thin areas No 12/22/2005 2005-0077 of the valve wall 3 Replacement SW-360 Replace valve No 2/1/2006 2005-0078 3 Corrective Measure SW-360 Remove[Replace tack weld No 12/22/2005 2005-0079 2 Replacement IP-002A Replace discharge check No 12/22/2005 2005-0081 valve Replacement 1PP-002A Replacement suction No 12/22/2005 2005-0082

... , no. A nbnn. tnt tov

ENCLOSURE 2 OAR-1, OWNER'S ACTIVITY REPORT FOR INSERVICE INSPECTION, FOR CLASS MC and CC COMPONENTS 4 pages follow

FORM OAR-I OWNER'S ACTIVITY REPORT Report Number U I R29 Outage Class MC ISI IWE Examinations Owner Nuclear Management Companv. 700 First Street. Hudson, Wisconsin 54016 (Name and Address of Owner)

Plant Point Beach Nuclear Plant, 6590 Nuclear Road. Two Rivers, Wisconsin 54241 (Name and Address of Plant)

Unit No. I Commercial Service Date December 21. 1970 Refueling Outage No. UIR29 (If applicable)

Current Inspection Interval First (I st, 2nd, 3rd, 4th, other)

Current Inspection Period Third (Ist, 2nd, 3rd)

Edition and Addenda of Section Xi applicable to the inspection plan 1992 Edition 1992 Addenda Date and Revision of inspection plan December 20, 2004 / rev. 1 Edition and Addenda of Section Xi applicable to repairs and replacements, if different than the inspection plan Same CERTIFICATE OF CONFORMANCE I certify that the statements made in the Owner's Activity Report are correct, and that the examinations, tests, repairs, replacements, evaluations, and corrective measures represented by this report conform to the requirements of Section Xl.

Certificate of Authorization No. N/A Expiration Date N/A J(If

_ _ applicable)

Signed -2§L 6/(i.7 /IWE & IW'L Progyram Enoineer Date  % / 0-C Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION 1,the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Wisconsin and employed by HSBCT of Hartford, Connecticut, have inspected the items described in this Owner's Activity Report, during the period June 9, 2004 to November 24, 2005, and state that to the best of my knowledge and belief, the Owner has performed all activities represented by this report in accordance with the requirements of Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations, tests, repairs, replacements, evaluations, and corrective measures described in this report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal inju or property damage or loss of any kind arising from the connected with this inspection.

Commissions WI 247972 prt&'s Signature National Board, State, Province, and Endorsements Date algwo064O1

Table I Abstract of Examinations and Tests Total Total Total Total Examinations Examinations Examinations Examinations Credited (%) to Examination Required for Credited for this Credited (%) Date for the Category the Interval Period for the Period Interval Remarks The number of liner plates examined, expressed as a percentage of exams, does not correlate to the containment surface area examined, expressed as a E-A 156 42 39% 13 13 p0%

percentage of surface area. This is because the containment liner consists of 100A different size liner plates; therefore, surface area wvill vary from plate to plate.

The percentages reflect the surface area of the plates that were examined and not the percentages of the number of examinations performed.

Containment Penetration Welds, Examination Category E-B examination E-B N/A N/A N/A N/A requirements specified in ASME Section Xl Code are not required.

Examination Category E-A requirements are considered sufficient to identify any degraded conditions for containment penetration welds.

E-C 33 33 100% 300% ,2 A 100 % is examined each period The exam percentages do not meet the IWE-2412-1 inspection program B examinations percents, because of the use of the authorized Relief Request #

E-D 68 A1 A1Af.0,1I3 ERR-I. Exam category E-D, Item Number E5.10 and E5.20 were examined in accordance with ERR- I starting after September 14, 200 1. The use of this ERR was authorized by the NRC in the safety evaluation for relief requests for the containment inspection program. (Dated September 14, 2001)

Pressure Retaining Dissimilar Metal Welds, Examination Category E-F E-F N/A N/A N/A N/A requirements specified in ASME Section Xl Code are not required and shall not be implemented by PBNP.

The exam percentages do not meet the IWE-2412-1 inspection program B examinations percents because of the use of the authorized Relief Request #

E-G 24 101 42% 1 75%

' ERR-6. Exam category E-G, Item Number E8.20 was examined in e accordance with ERR-6 starting after September 14, 2001. The use of this ERR was authorized by the NRC in the safety evaluation for relief requests for the containment inspection program. (Dated September 14, 2001)

This is covered by PBNP's Containment Leakage Rate Testing Program (CLRT), which implements 10 CFR 50 Appendix J. All Examination E-P See remarks See remarks See remarks See remarks Category E-P pressure retaining components are tested in accordance with 10 CFR 50 Appendix J, Option B and scheduled as directed by the CLRT

___ _______ __ ___ ___ ___ _ _ ___ ___ ___ ___ program .

Refer to the remarks column 2Category E-C (Augmented examinations) examinations are performed once a period, which means all of the exams, will be performed 3 times over a 10 year interval 3All percentages are rounded to the nearest I%.

Table 2 Items with Flaws or Relevant Conditions that Required Evaluation for Continued Service Flaw or Relevant Condition w .i Found During Scheduled Flaw Characterization Section XI Examination or Test Examination Category Item No. Item Description (IWA-3300) (Yes or No)

None None None None None

Table 3 Abstract of Repairs, Replacements, or Corrective Measures Required for Continued Service Flaw or Relevant Condition Found During Scheduled Section XI Repair/

Code Repair, Replacement, Examination or Test Date Replacement Class or Corrective Measure Item Description Description of Work (Yes or No) Completed Plan Number MC Replacement C-I Replaced hinge pins Yes 1/11/2006 2005-0076

_ _______ ____ ____ ____ ___ under W O _04 15764 _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _