NEXTera**

EN E RGY~

July 15, 2014 NRC 2014-0048 10 CFR 50.55a U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555 Point Beach Nuclear Plant, Unit 2 Docket 50-301 Renewed License No. DPR-27 Filing of Owner's lnservice Inspection Summary Report Class 1, 2 and 3 for Point Beach Nuclear Plant Refueling Outage U2R33 NextEra Energy Point Beach, LLC (NextEra) is submitting inservice inspection summary reports for inspections conducted prior to and during the Point Beach Nuclear Plant (PBNP) refueling outage U2R33 that concluded on April 18, 2014. The enclosed Class 1, 2 and 3 report is submitted pursuant to the requirements of Subarticle IWA-6240 of the 2007 Edition with Addenda through 2008 of Section XI of the American Society of Mechanical Engineers (ASME) Boiler and Pressure Vessel Code and ASME Code Case N-532-5.

The Enclosure to this letter contains the alternate to the summary report, Form OAR-1, "Owner's Activity Report" for inservice inspections for the Class 1, 2 and 3 components. The report is for the second outage of the First Period of the Fifth 10-year Interval for Class 1, 2 and 3 systems at PBNP Unit 2.

Very truly yours, NextEra Energy Point Beach , LLC Michael Millen Licensing Manager Enclosures cc: Administrator, Region Ill, USNRC Project Manager, Point Beach Nuclear Plant, USNRC Resident Inspector, Point Beach Nuclear Plant, USNRC PSCW Mike Verhagen, State of Wisconsin NextEra Energy Point Beach, LLC, 66 10 Nuclear Road, Two Rivers, WI 54241

ENCLOSURE NEXTERA ENERGY POINT BEACH, LLC POINT BEACH NUCLEAR PLANT, UNIT 2 OAR-1, OWNER'S ACTIVITY REPORT FOR INSERVICE INSPECTION, FOR CLASS 1, 2 AND 3 COMPONENTS 3 pages follow

FORM OAR-I OWNER'S ACTIVITY REPORT Repmi Number _ _ _ _ __,U"'2"'R""3"'3"--"'0'""u"'ta""g""e--'C""I"'a"'ss'--'-'1,'-'2'-,_,

'- a""'n"'"d-"'3-'I""S_,_I-=E"-'x_,_ai'""n"'in"'a,_,_II,*_o"'n'-----------------

Plant NextEra Energy Point Beach Nuclear Plant, 6610 Nuclear Road, Two Rivers, Wisconsin 54241 Unit No. _ _ _____.2'------- Commercial Service Date _0"'-"'ct"'o""b"'et""'

  • 1'-'--'l.L.9.L72"'---- - - -- Refueling Outage No. _ _____,U""2""'R""'3"'3'--------

(If applicable)

CmTent Inspection Interval Fifth (1st, 2nd, 3rd, 4th, other)

Current Inspection Period First (1st, 2nd, 3rd)

Edition and Addenda of Section XI applicable to the inspection plans 2007 Edition 2008 Addenda Date and Revision of inspection plans July 31, 2012 / Revision 12 Edition and Addenda of Section XI applicable to repairs/replacements activities, if different than the inspection plans ,S_,_m'"n,e " _ _ _ _ _ _ __

Code Cases used for inspection and evaluation: _ ___,N""-~5"'3"'2--'-5"-'--"N_,_--'-7-"0""6_,-l'-'--'-N-'---'-7_,_16"-'---'-N,_-""72"'2"---"l~N"-'---7'-'2""9'---'-1'-'N'-'---7'-'7"'0'---'-1---

(If applicable, including cases modified by Case N-532 and later revisions)

CERTIFICATE OF CONFORMANCE I ceiiify that (a) the statements made in this repmi are correct; (b) the examinations and tests meet the Inspection Plan as required by the ASME Code,Section XI; and (c) the repair/replacement activities and evaluations suppmiing the completion of _ _ _ _ _ __,U"-'2""R"'3""3'------------

(refueling outage number)

CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid conm1ission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Wisconsin and employed by HSB Global Standards have inspected the items described in tlus Owner's Activity Repmi, and state that, to the best of my knowledge and belief, the Owner has performed all activities represented by tlus repo1i in accordance with the requirements of Section XI.

By signing this ce1iificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the repair/replacement activities and evaluations described in tlus repmi. Fmihermore, neither the Inspector nor Ius employer shall be liable in any manner for any personal iqjury or prope1iy damage or los \. of any kind arising from or cmmected with this inspection.


f~,.., ~J~U-

"--1'-s-l'r-to--'r"' ~

's=-s""i'--g-n-at-u-re_ _ _ __ _ __ _ __ _ Cmrunissions WI 929625 A,I,N National Board, State, Province, and Endorsements

Table 1 Items with Flaws or Relevant Conditions that Required Evaluation for Continued Service Examination Category and Item Number Item Description Evaluation Description None None None

Table 2 Abstract of Repair/Replacement Activities Required for Continued Service Repair/

Replacement Date Plan Code Class Item Description Description of Work Completed Number 28 Dome Truss bolts needed Containment to be repositioned to meet 2 Dome Truss 4/10/14 2014-0039 current analysis of allowed Bolting loads .

Replace Missing 2SC-00953 valve yoke-to-1 4/10/14 2014-0041 Support Bolting lateral support bolt replaced Replace Missing 2CC-00761 B valve yoke-to-2 4/10/14 2014-0042 Support Bolting lateral support bolt replaced