February 11,201 0 NRC 201 0-001 8 10 CFR 50.55a U.S. Nuclear Regulatory Commission AWN: Document Control Desk Washington, DC 20555 Point Beach Nuclear Plant, Unit 2 Docket 50-301 License No. DPR-27 Filing of Owner's Inservice lns~ection Summaw Re~ort for Point Beach Nuclear Plant Refueling Outage U2R30 NextEra Energy Point Beach, LLC (NextEra), is submitting inservice inspection summary reports for inspections conducted prior to and during Point Beach Nuclear Plant (PBNP) refueling outage U2R30 that concluded on December 6,2009. The enclosed Class I, 2 and 3 report is submitted pursuant to the requirements of Subarticle IWA-6240 of the 1998 Edition with Addenda through 2000 of Section XI of the American Society of Mechanical Engineers (ASME) Boiler and Pressure Vessel Code and ASME Code Case N-532-4.

The enclosure to this letter contains the alternate to the summary report, Form OAR-1, "Owner's Activity Report" for inservice inspections for the Class 1, 2 and 3 components. 'The report is for the first outage of the Third Period of the Fourth 10-Year Interval for Class I, 2 and 3 systems at PBNP Unit 2.

Very truly yours, NextEra Energy Point Beach, LLC w Licensing Manager Enclosures cc:

Administrator, Region Ill, USNRC Project Manager, Point Beach Nuclear Plant, USNRC Resident Inspector, Point Beach Nuclear Plant, USNRC PSCW Mike Verhagen, State of Wisconsin NextEra Energy Point Beach, LLC, 6610 Nuclear Road, Two Rivers, WI 54241

ENCLOSURE 1 NEXTERA ENERGY POINT BEACH, LLC POINT BEACH NUCLEAR PLANT, UNIT 2 OAR-1, OWNER'S ACTIVITY REPORT FOR INSERVICE INSPECTION FOR CLASS l, 2 AND 3 COMPONENTS 3 pages follow

FORM OAR-1 OWNER'S ACTIVITY E P O R T Report Number U2R30 Outage Class 1.2. and 3 IS1 Examination Plant FPLE Point Beach Nuclear Plant, 6610 Nuclear Road. Two Rivers, Wisconsin 54241 Unit No.

2 Commercial Service Date October 1. 1972 Refueling Outage No.

U2R30 (If applicable)

Current Inspection Interval Fourth (1 st, 2nd, 3rd, 4th, other)

Current Inspection Period Third (Ist, 2nd, 3rd)

Edition and Addenda of Section XI applicable to the inspection plans 1998 Edition 2000 Addenda Date and Revision of inspection plans February 13.2009 /Revision 7 Edition and Addenda of Section XI applicable to repairslreplacements activities, if different than the inspection plans Same Code Cases used:

N-460. N-498-4 (CL 3 only). N-532-4. N-533-1. N-566-2, N-624, N-648-1. N-722, N-729-1 (If applicable)

CERTIFICATE OF CONFORMANCE I certify that (a) the statements made in this report are correct; (b) the examinations and tests meet the Inspection Plan as required by the ASME Code,Section XI; and (c) the repairlreplacement activities and evaluations supporting the completion of U2R30 (refueling outage number) conform to the requirements of Section XI.

Signed Date ~A-ZO/O CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Wisconsin and employed by Hartford Steam Boiler of CT have inspected the items described in this Owner's Activity Report, and state that, to the best of my knowledge and belief, the Owner has performed all activities represented by this report in accordance with the requirements of Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the repairlreplacement activities and evaluations described in this report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any lcind arising from or connected with this inspection.

I Commissions WI 929625 A,I,N National Board, State, Province, and Endorsements Date

/ ~//CO

/ /[

1

Category and ltem Number Table 1 Items with Flaws or Relevant Conditions that Required Evaluation for Continued Service Examination I None Item Description None Evaluation Description None

Table 2 Abstract of RepairIReplacement Activities Required for Continued Service Code Class 2

Date Completed 12/6/2009 Repair/

Replacement Plan Number 2009-0088 Item Description 3" Main Piping Description of Work Approximately 30" length of piping replaced due to FAC thinning