NRC 2013-0015, Filing of Owner'S Lnservice Lnspection Summary Report Class 1, 2 and 3 for Refueling Outage U2R32

From kanterella
Jump to navigation Jump to search
Filing of Owner'S Lnservice Lnspection Summary Report Class 1, 2 and 3 for Refueling Outage U2R32
ML13052A005
Person / Time
Site: Point Beach NextEra Energy icon.png
Issue date: 02/19/2013
From: Millen M
Point Beach
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
NRC 2013-0015
Download: ML13052A005 (5)


Text

February 19,201 3 EN?

NRC 2013-0015 10 CFR 50.55a POINT b m C H U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555 Point Beach Nuclear Plant, Unit 2 Docket 50-301 Renewed License No. DPR-27 Filing of Owner's lnservice lnseection Summarv Reeort Class 1,2 and 3 for Point Beach Nuclear Plant Refuelinu Outaue U2R32 NextEra Energy Point Beach, LLC (NextEra) is submitting inservice inspection summary reports for inspections conducted prior to and during the Point Beach Nuclear Plant (PBNP) refueling outage U2R32 that concluded on November 30,2012. The enclosed Class 1,2 and 3 report is submitted pursuant to the requirements of Subarticle IWA-6240 of the 2007 Edition with Addenda through 2008 of Section XI of the American Society of Mechanical Engineers (ASME) Boiler and Pressure Vessel Code and ASME Code Case N-532-4. of this letter contains the alternate to the summary report, Form OAR-1, "Owner's Activity Report" for insewice inspections for the Class 1,2 and 3 components. The report is for the first outage of the First Period of the Fifth 10-year Interval for Class 1,2 and 3 systems at PBNP Unit 2.

Very truly yours, NextEra Energy Point Beach, LLC Mike Millen Licensing Manager Enclosures cc: Administrator, Region Ill, USNRC Project Manager, Point Beach Nuclear Plant, USNRC Resident Inspector, Point Beach Nuclear Plant, USNRC PSCW Mike Verhagen, State of Wisconsin NextEra Energy Point Beach, LLC, 6610 Nuclear Road, Two Rivers, WI 54241

ENCLOSURE 1 NEXTERA ENERGY POINT BEACH, LLC POINT BEACH NUCLEAR PLANT, UNIT 2 OAR-1, OWNER'S ACTIVITY REPORT FOR INSERVICE INSPECTION.

FOR CLASS 1,2 AND 3 COMPONENTS 3 pages follow

FORM OAR- 1 0WNER'S ACTIVITY REPORT Report Number U2R32 Outane Class 1.2, and 3 IS1 Examination Plant NextEra Energv Point Beach Nuclear Plant, 6610 Nuclear Road. Two Rivers. Wisconsin 54241 Unit No. 2 Commercial Service Date October 1, 1972 Refbeling Outage No. U2R32 (If applicable)

Current Inspection Interval Fifth (lst, 2nd, 3rd, 4th, other)

Current Inspection Period First (lst, 2nd, 3rd)

Edition and Addenda of Section XI applicable to the inspection plans 2007 Edition 2008 Addenda Date and Revision of inspection plans July 31,2012 /Revision 12 Edition and Addenda of Section XI applicable to repairsireplacenients activities, if different than the inspection plans Same Code Cases used for inspection and evaluation: N-532-5, N-619. N-706-1, N-722-1, N-729-1, N-770-1 (If applicable, including cases modified by Case N-532 and later revisions)

CERTIFICATE OF CONFORMANCE I certify that (a) the statements made in this report are correct; (b) the examinations and tests meet the Inspection Plan as required by the ASME Code,Section XI; and (c) the repairlreplacement activities and evaluations supporting the completion of U2R32 (refueling outage number) conform to the requirements of Section XI.

Signed signee, Title IS1 Proeram Owner Date /

2 1 $3 (20/ 1 CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Wisconsin and employed by Hartford Steam Boiler of CT have inspected the items described in this Owner's Activity Report, and state that, to the best of my knowledge and belief, the Owner has performed all activities represented by this report in accordance with the requirements of Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the repairireplacement activities and evaluations described in this report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.

Commissions WI 929625 A,I,N National Board, State, Province, and Endorsements Date ;s/ l ? / / 3 I

Table 1 Items with Flaws or Relevant Conditions that Required Evaluation for Continued Service Examination Category and ltem Number Item Description Evaluation Description None None None

Table 2 Abstract of RepairIReplacement Activities Required for Continued Service Repair1 Replacement Date Plan Code Class Item Description Description of Work Completed Number None None None None None