Category:INSPECTION REPORT
MONTHYEARIR 05000219/19980121999-03-0404 March 1999 Insp Rept 50-219/98-12 During Periods 981214-18,990106-07 & 20-22.No Violations Identified.Major Areas Inspected: Review of Licensee self-assessment of Plant Environ Qualification Program & Corrective Actions for Open Items IR 05000219/19980091998-11-25025 November 1998 Insp Rept 50-219/98-09 on 980914-1025.Violations Noted. Major Areas Inspected:Operations,Engineering,Maintenance & Plant Support IR 05000219/19980081998-10-20020 October 1998 Insp Rept 50-219/98-08 on 980727-0913.No Violations Noted. Major Areas Inspected:Licensee Operations,Engineering,Maint & Plant Support IR 05000219/19980051998-08-26026 August 1998 Insp Rept 50-219/98-05 on 980614-0726.No Violations Noted. Major Areas Inspected:Plant Operations,Maint,Engineering & Plant Support IR 05000219/19980071998-07-0202 July 1998 Insp Rept 50-219/98-07 on 980615-19.No Violations Noted. Major Areas Inspected:Status of Plant motor-operated Valve Program to Determine Acceptability for Closure of NRC Review Under GL 89-10 ML20217F6641998-04-22022 April 1998 Insp Rept 50-219/98-80 on 980223-0313 & 0330-0402.Violations Noted.Major Areas Inspected:Engineering ML20216H1911998-04-15015 April 1998 Insp Rept 50-219/98-04 on 980226-0318.Violations Noted.Major Areas Inspected:Operations,Maint & Plant Support IR 05000219/19970081997-12-0404 December 1997 Insp Rept 50-219/97-08 on 971020-24.No Violations Noted. Major Areas Inspected:Onsite Emergency Plan IR 05000219/19970041997-07-29029 July 1997 Insp Rept 50-219/97-04 on 970526-0706.Violations Noted. Major Areas Inspected:Aspects of Licensee Operations, Engineering,Maint & Plant Support IR 05000219/19970051997-07-17017 July 1997 Insp Rept 50-219/97-05 on 970407-11.No Violations Noted. Major Areas Inspected:Engineering ML20141G9431997-07-0303 July 1997 Insp Rept 50-219/97-03 on 970414-0525.Violations Noted.Major Areas Inspected:Operations,Maint,Engineering & Plant Support IR 05000219/19970021997-05-19019 May 1997 Insp Rept 50-219/97-02 on 970224-0413.Violations Noted. Major Areas Inspected:Operations,Engineering,Maintenance & Plant Support ML20137E9491997-03-21021 March 1997 Insp Rept 50-219/97-01 on 970113-0223.Violations Noted.Major Areas Inspected:Licensee Operations,Engineering,Maint & Plant Support IR 05000219/19960101996-09-27027 September 1996 Insp Rept 50-219/96-10 on 960923-27.No Violations Noted. Major Areas Inspected:Radiological Source Term Assessment, Results of Exposure Reduction Initiatives & Evidence of Station ALARA Program IR 05000219/19960111996-01-0202 January 1996 Insp Rept 50-219/96-11 on 961021-1201.Violations Noted.Major Areas Inspected:Licensee Operations,Engineering,Maint & Plant Support IR 05000219/19930811993-12-22022 December 1993 Insp Rept 50-219/93-81 on 930927-1015.Violations Noted.Major Areas Inspected:Engineering,Maint,Surveillance & Mgt & Corrective Actions IR 05000219/19930261993-11-18018 November 1993 Insp Rept 50-219/93-26 on 931101-05.No Violations Noted. Major Areas Inspected:Mgt Support,Security Program Plans & Audits,Protected & Vital Area Access Control of Personnel & Packages & Vehicles IR 05000219/19930241993-11-18018 November 1993 Insp Rept 50-219/93-24 on 930921-1101.Violations Noted.Major Areas Inspected:Plant Operations,Maint,Engineering,Plant Support,Including Security & Emergency Preparedness & Safety Assessment/Quality Verification ML20058A3791993-11-12012 November 1993 Insp Rept 50-219/93-23 on 931018-20.Onsite Response to Exercise Scenario Was Good.Major Areas inspected:full- Participation Ingestion Pathway Emergency Preparedness Exercise IR 05000219/19930251993-11-0909 November 1993 Insp Rept 50-219/93-25 on 931018-22.No Violations Noted. Major Areas Inspected:Design Mods & Engineering Support ML20059F6251993-10-28028 October 1993 Insp Rept 50-219/93-22 on 930920-24.No Violations Noted. Major Areas Inspected:Addressed Open Items Associated W/Eop & Reviewed Licensee Actions in Response to Violations Associated W/Recirculation Loop Isolation Event IR 05000219/19930181993-10-28028 October 1993 Insp Rept 50-219/93-18 on 930823-1020.No Violations Noted. Major Areas Inspected:Alara,Rirs,Qa Audits,Air & Swipe Sample Counting Facilities & Radiological Controls Organization Professional Staffing IR 05000219/19930201993-10-19019 October 1993 Insp Rept 50-219/93-20 on 930816-930917.No Violations Noted. Major Areas Inspected:Radioactive Liquid & Gaseous Effluent Control Programs Including Mgt Controls & QA Audits IR 05000219/19930211993-10-15015 October 1993 Insp Rept 50-219/93-21 on 930810-0920.No Violations Noted. Major Areas Inspected:Operations,Maint,Engineering,Plant Support & Safety Assessment/Quality Verification IR 05000219/19930111993-09-10010 September 1993 Insp Rept 50-219/93-11 on 930629-0809.No Violations Noted. Major Areas Inspected:Day Shift & Back Shift Hours of Station Activities IR 05000219/19930191993-09-0909 September 1993 Insp Rept 50-219/93-19 on 930816-20.Violations Noted.Major Areas Inspected:Radiological Environ Monitoring Program & Meteorological Monitoring Program IR 05000219/19930141993-09-0202 September 1993 EP Insp Rept 50-219/93-14 on 930802-05.Concerns Noted. Major Areas Inspected:Epip,Equipment,Instrumentation & Supplies IR 05000219/19930161993-08-27027 August 1993 Insp Rept 50-219/93-16 on 930726-30.Major Areas Inspected: Erosion/Corrosion Insp Program,Per GL 89-08.Program & Program Implementation Generally Good.Staff Responsible for Program Development & Implementation Qualified IR 05000219/19930121993-08-26026 August 1993 Insp Rept 50-219/93-12 on 930706-09.No Violations Noted. Major Areas Inspected:Licensee Progress in Incorporating EQ Component Info Into GMS2 Computer Database IR 05000219/19920221993-03-19019 March 1993 Mobile NDE Lab Insp 50-219/92-22 on 921207-11 & 930111-15. No Violations Noted.Major Areas Inspected:Cs,Css,Sdc,Ms & FW Sys IR 05000219/19920251993-02-10010 February 1993 Insp Rept 50-219/92-25 on 921215-930118.Violations Noted. Major Areas Inspected:Plant Operations,Radiological Control, Maint & Surveillance,Engneering & Technical Support, Emergency Preparedness & Security IR 05000219/19930011993-01-29029 January 1993 Insp Rept 50-219/93-01 on 930104-08.No Radiological Safety Concerns or Violations Noted.Major Areas Inspected:Postings & Other in Plant Radiological Controls,Work in Progress, Housekeeping & Self Reading Dosimeter Use IR 05000219/19920231992-12-24024 December 1992 Insp Rept 50-219/92-23 on 921103-1214.No Violations Noted. Major Areas Inspected:Plant Operations,Security & Safety Assessment/Quality Verification IR 05000219/19910041991-03-0101 March 1991 Partially Withheld Insp Rept 50-219/91-04 on 910204-07.No Violations Noted.Major Areas Inspected:Protected Area Physical Barriers,Isolation Zones & Lighting,Protected Area Access Control of Personnel & Security Training IR 05000219/19900191990-11-16016 November 1990 Insp Rept 50-219/90-19 on 900923-1020.Violations Noted. Areas Inspected:Radiological Protection,Surveillance & Maintenance,Emergency Preparedness,Security,Engineering & Technical Support & Safety Assessment/Quality Verification IR 05000219/19900201990-11-0202 November 1990 Insp Rept 50-219/90-20 on 901022-26.No Violations Noted. Major Areas Inspected:Internal Exposure Control & Review of Procedures for Drywell Occupancy During Fuel Movement IR 05000219/19900161990-10-18018 October 1990 Insp Rept 50-219/90-16 on 900823-0922.Violations Noted.Major Areas Inspected:Observation of Plant Activities,Review of Operational Events,Operation of Turbine Bldg Ventilation Sys & Walkdown of Emergency Diesel Fuel Oil Transfer Sys ML20058F3241990-10-0202 October 1990 Insp Rept 50-219/90-17 on 900918-21.No Violations Noted. Major Areas Inspected:Transportation & Solid Radwaste Programs IR 05000219/19900151990-09-20020 September 1990 Partially Withheld Safeguards Insp Rept 50-219/90-15 on 900820-24 (Ref 10CFR73.21).No Violations Noted.Major Areas Inspected:Support,Security Program Plans,Audits,Protected & Vital Areas Physical Barriers,Power Supply & Testing IR 05000219/19900111990-08-15015 August 1990 Insp Rept 50-219/90-11 on 900610-0711.Noncited Violation Noted.Major Areas Inspected:Observation & Review of Plant Operations,Review of Radiological Controls & Routine Observations of Maint Activities & Surveillance Tests ML20056A6191990-07-19019 July 1990 Insp Rept 50-219/90-09 on 900422-0609.Violations Noted. Major Areas Inspected:Observation & Review of Routine Plant Activities & Operational Events,Site Radiological Controls & Events & Observations of Corrective Maint Activities IR 05000219/19890291990-02-16016 February 1990 Insp Rept 50-219/89-29 on 891203-900106.Major Areas Inspected:Observation & Review of Plant Operational Events, Condenser Vacuum Transient,Unusual Events Due to Low Intake Water Level & Simultaneous Movement of Two Control Rods IR 05000219/19890181989-09-13013 September 1989 Insp Rept 50-219/89-18 on 890724-28.No Violations Noted. Major Areas Inspected:Review of Licensee Actions on Previous NRC Concerns,Atws Rule Implementation,Procurement Control & non-licensed Operators Training IR 05000219/19890201989-09-0707 September 1989 Insp Rept 50-219/89-20 on 890829-30.No Exercise Weaknesses Noted.Major Areas Inspected:Licensee Emergency Preparedness Exercise Conducted on 890829-30 ML20246J6261989-08-18018 August 1989 Insp Rept 50-219/89-16 on 890702-29.Violations Noted.Major Areas Inspected:Plant Operational Events,Control of High Radiation Areas,Evaluation of Plant Operation W/High Canal Water Temps & Security Response to Vital Area Door Problem IR 05000219/19890191989-08-15015 August 1989 Insp Rept 50-219/89-19 on 890802-04.No Violations or Deviations Noted.Major Areas Inspected:Solid Radwaste Sys & Transportation Programs,Including Mgt Controls,Audits,Qa & Implementation of Subj Programs IR 05000219/19890151989-08-0909 August 1989 Insp Rept 50-219/89-15 on 890627-30.No Violations Noted. Major Areas Inspected:Organization & Qualifications of Radiological Controls Personnel in Site Organization IR 05000219/19890141989-08-0303 August 1989 Insp Rept 50-219/89-14 on 890604-0701.No Violations Noted. Major Areas Inspected:Core Spray Booster Pump Trips,Under Voltage Relay Failure,Monthly Surveillance Observations, Emergency Svc Water Pump Operability & Oyster Creek Drawing IR 05000219/19890111989-07-25025 July 1989 Insp Rept 50-219/89-11 on 890606-08.Major Areas Inspected: Emergency Preparedness Insp of full-participation Exercise of Licensee Emergency Plan Conducted on 890607.Exercise Did Not Meet Requirements for Annual Test of Emergency Plan IR 05000219/19890121989-07-21021 July 1989 Insp Rept 50-219/89-12 on 890430-0603.Violations Noted.Major Areas Inspected:Plant Operational Events Including Three Reactor Startups & Licensee Corrective Actions Re Reactor Coolant Pressure Boundary Hangers Being Pinned 1999-03-04
[Table view] Category:NRC-GENERATED
MONTHYEARIR 05000219/19980121999-03-0404 March 1999 Insp Rept 50-219/98-12 During Periods 981214-18,990106-07 & 20-22.No Violations Identified.Major Areas Inspected: Review of Licensee self-assessment of Plant Environ Qualification Program & Corrective Actions for Open Items IR 05000219/19980091998-11-25025 November 1998 Insp Rept 50-219/98-09 on 980914-1025.Violations Noted. Major Areas Inspected:Operations,Engineering,Maintenance & Plant Support IR 05000219/19980081998-10-20020 October 1998 Insp Rept 50-219/98-08 on 980727-0913.No Violations Noted. Major Areas Inspected:Licensee Operations,Engineering,Maint & Plant Support IR 05000219/19980051998-08-26026 August 1998 Insp Rept 50-219/98-05 on 980614-0726.No Violations Noted. Major Areas Inspected:Plant Operations,Maint,Engineering & Plant Support IR 05000219/19980071998-07-0202 July 1998 Insp Rept 50-219/98-07 on 980615-19.No Violations Noted. Major Areas Inspected:Status of Plant motor-operated Valve Program to Determine Acceptability for Closure of NRC Review Under GL 89-10 ML20217F6641998-04-22022 April 1998 Insp Rept 50-219/98-80 on 980223-0313 & 0330-0402.Violations Noted.Major Areas Inspected:Engineering ML20216H1911998-04-15015 April 1998 Insp Rept 50-219/98-04 on 980226-0318.Violations Noted.Major Areas Inspected:Operations,Maint & Plant Support IR 05000219/19970081997-12-0404 December 1997 Insp Rept 50-219/97-08 on 971020-24.No Violations Noted. Major Areas Inspected:Onsite Emergency Plan IR 05000219/19970041997-07-29029 July 1997 Insp Rept 50-219/97-04 on 970526-0706.Violations Noted. Major Areas Inspected:Aspects of Licensee Operations, Engineering,Maint & Plant Support IR 05000219/19970051997-07-17017 July 1997 Insp Rept 50-219/97-05 on 970407-11.No Violations Noted. Major Areas Inspected:Engineering ML20141G9431997-07-0303 July 1997 Insp Rept 50-219/97-03 on 970414-0525.Violations Noted.Major Areas Inspected:Operations,Maint,Engineering & Plant Support IR 05000219/19970021997-05-19019 May 1997 Insp Rept 50-219/97-02 on 970224-0413.Violations Noted. Major Areas Inspected:Operations,Engineering,Maintenance & Plant Support ML20137E9491997-03-21021 March 1997 Insp Rept 50-219/97-01 on 970113-0223.Violations Noted.Major Areas Inspected:Licensee Operations,Engineering,Maint & Plant Support IR 05000219/19960101996-09-27027 September 1996 Insp Rept 50-219/96-10 on 960923-27.No Violations Noted. Major Areas Inspected:Radiological Source Term Assessment, Results of Exposure Reduction Initiatives & Evidence of Station ALARA Program IR 05000219/19960111996-01-0202 January 1996 Insp Rept 50-219/96-11 on 961021-1201.Violations Noted.Major Areas Inspected:Licensee Operations,Engineering,Maint & Plant Support IR 05000219/19930811993-12-22022 December 1993 Insp Rept 50-219/93-81 on 930927-1015.Violations Noted.Major Areas Inspected:Engineering,Maint,Surveillance & Mgt & Corrective Actions IR 05000219/19930261993-11-18018 November 1993 Insp Rept 50-219/93-26 on 931101-05.No Violations Noted. Major Areas Inspected:Mgt Support,Security Program Plans & Audits,Protected & Vital Area Access Control of Personnel & Packages & Vehicles IR 05000219/19930241993-11-18018 November 1993 Insp Rept 50-219/93-24 on 930921-1101.Violations Noted.Major Areas Inspected:Plant Operations,Maint,Engineering,Plant Support,Including Security & Emergency Preparedness & Safety Assessment/Quality Verification ML20058A3791993-11-12012 November 1993 Insp Rept 50-219/93-23 on 931018-20.Onsite Response to Exercise Scenario Was Good.Major Areas inspected:full- Participation Ingestion Pathway Emergency Preparedness Exercise IR 05000219/19930251993-11-0909 November 1993 Insp Rept 50-219/93-25 on 931018-22.No Violations Noted. Major Areas Inspected:Design Mods & Engineering Support ML20059F6251993-10-28028 October 1993 Insp Rept 50-219/93-22 on 930920-24.No Violations Noted. Major Areas Inspected:Addressed Open Items Associated W/Eop & Reviewed Licensee Actions in Response to Violations Associated W/Recirculation Loop Isolation Event IR 05000219/19930181993-10-28028 October 1993 Insp Rept 50-219/93-18 on 930823-1020.No Violations Noted. Major Areas Inspected:Alara,Rirs,Qa Audits,Air & Swipe Sample Counting Facilities & Radiological Controls Organization Professional Staffing IR 05000219/19930201993-10-19019 October 1993 Insp Rept 50-219/93-20 on 930816-930917.No Violations Noted. Major Areas Inspected:Radioactive Liquid & Gaseous Effluent Control Programs Including Mgt Controls & QA Audits IR 05000219/19930211993-10-15015 October 1993 Insp Rept 50-219/93-21 on 930810-0920.No Violations Noted. Major Areas Inspected:Operations,Maint,Engineering,Plant Support & Safety Assessment/Quality Verification IR 05000219/19930111993-09-10010 September 1993 Insp Rept 50-219/93-11 on 930629-0809.No Violations Noted. Major Areas Inspected:Day Shift & Back Shift Hours of Station Activities IR 05000219/19930191993-09-0909 September 1993 Insp Rept 50-219/93-19 on 930816-20.Violations Noted.Major Areas Inspected:Radiological Environ Monitoring Program & Meteorological Monitoring Program IR 05000219/19930141993-09-0202 September 1993 EP Insp Rept 50-219/93-14 on 930802-05.Concerns Noted. Major Areas Inspected:Epip,Equipment,Instrumentation & Supplies IR 05000219/19930161993-08-27027 August 1993 Insp Rept 50-219/93-16 on 930726-30.Major Areas Inspected: Erosion/Corrosion Insp Program,Per GL 89-08.Program & Program Implementation Generally Good.Staff Responsible for Program Development & Implementation Qualified IR 05000219/19930121993-08-26026 August 1993 Insp Rept 50-219/93-12 on 930706-09.No Violations Noted. Major Areas Inspected:Licensee Progress in Incorporating EQ Component Info Into GMS2 Computer Database IR 05000219/19920221993-03-19019 March 1993 Mobile NDE Lab Insp 50-219/92-22 on 921207-11 & 930111-15. No Violations Noted.Major Areas Inspected:Cs,Css,Sdc,Ms & FW Sys IR 05000219/19920251993-02-10010 February 1993 Insp Rept 50-219/92-25 on 921215-930118.Violations Noted. Major Areas Inspected:Plant Operations,Radiological Control, Maint & Surveillance,Engneering & Technical Support, Emergency Preparedness & Security IR 05000219/19930011993-01-29029 January 1993 Insp Rept 50-219/93-01 on 930104-08.No Radiological Safety Concerns or Violations Noted.Major Areas Inspected:Postings & Other in Plant Radiological Controls,Work in Progress, Housekeeping & Self Reading Dosimeter Use IR 05000219/19920231992-12-24024 December 1992 Insp Rept 50-219/92-23 on 921103-1214.No Violations Noted. Major Areas Inspected:Plant Operations,Security & Safety Assessment/Quality Verification IR 05000219/19910041991-03-0101 March 1991 Partially Withheld Insp Rept 50-219/91-04 on 910204-07.No Violations Noted.Major Areas Inspected:Protected Area Physical Barriers,Isolation Zones & Lighting,Protected Area Access Control of Personnel & Security Training IR 05000219/19900191990-11-16016 November 1990 Insp Rept 50-219/90-19 on 900923-1020.Violations Noted. Areas Inspected:Radiological Protection,Surveillance & Maintenance,Emergency Preparedness,Security,Engineering & Technical Support & Safety Assessment/Quality Verification IR 05000219/19900201990-11-0202 November 1990 Insp Rept 50-219/90-20 on 901022-26.No Violations Noted. Major Areas Inspected:Internal Exposure Control & Review of Procedures for Drywell Occupancy During Fuel Movement IR 05000219/19900161990-10-18018 October 1990 Insp Rept 50-219/90-16 on 900823-0922.Violations Noted.Major Areas Inspected:Observation of Plant Activities,Review of Operational Events,Operation of Turbine Bldg Ventilation Sys & Walkdown of Emergency Diesel Fuel Oil Transfer Sys ML20058F3241990-10-0202 October 1990 Insp Rept 50-219/90-17 on 900918-21.No Violations Noted. Major Areas Inspected:Transportation & Solid Radwaste Programs IR 05000219/19900151990-09-20020 September 1990 Partially Withheld Safeguards Insp Rept 50-219/90-15 on 900820-24 (Ref 10CFR73.21).No Violations Noted.Major Areas Inspected:Support,Security Program Plans,Audits,Protected & Vital Areas Physical Barriers,Power Supply & Testing IR 05000219/19900111990-08-15015 August 1990 Insp Rept 50-219/90-11 on 900610-0711.Noncited Violation Noted.Major Areas Inspected:Observation & Review of Plant Operations,Review of Radiological Controls & Routine Observations of Maint Activities & Surveillance Tests ML20056A6191990-07-19019 July 1990 Insp Rept 50-219/90-09 on 900422-0609.Violations Noted. Major Areas Inspected:Observation & Review of Routine Plant Activities & Operational Events,Site Radiological Controls & Events & Observations of Corrective Maint Activities IR 05000219/19890291990-02-16016 February 1990 Insp Rept 50-219/89-29 on 891203-900106.Major Areas Inspected:Observation & Review of Plant Operational Events, Condenser Vacuum Transient,Unusual Events Due to Low Intake Water Level & Simultaneous Movement of Two Control Rods IR 05000219/19890181989-09-13013 September 1989 Insp Rept 50-219/89-18 on 890724-28.No Violations Noted. Major Areas Inspected:Review of Licensee Actions on Previous NRC Concerns,Atws Rule Implementation,Procurement Control & non-licensed Operators Training IR 05000219/19890201989-09-0707 September 1989 Insp Rept 50-219/89-20 on 890829-30.No Exercise Weaknesses Noted.Major Areas Inspected:Licensee Emergency Preparedness Exercise Conducted on 890829-30 ML20246J6261989-08-18018 August 1989 Insp Rept 50-219/89-16 on 890702-29.Violations Noted.Major Areas Inspected:Plant Operational Events,Control of High Radiation Areas,Evaluation of Plant Operation W/High Canal Water Temps & Security Response to Vital Area Door Problem IR 05000219/19890191989-08-15015 August 1989 Insp Rept 50-219/89-19 on 890802-04.No Violations or Deviations Noted.Major Areas Inspected:Solid Radwaste Sys & Transportation Programs,Including Mgt Controls,Audits,Qa & Implementation of Subj Programs IR 05000219/19890151989-08-0909 August 1989 Insp Rept 50-219/89-15 on 890627-30.No Violations Noted. Major Areas Inspected:Organization & Qualifications of Radiological Controls Personnel in Site Organization IR 05000219/19890141989-08-0303 August 1989 Insp Rept 50-219/89-14 on 890604-0701.No Violations Noted. Major Areas Inspected:Core Spray Booster Pump Trips,Under Voltage Relay Failure,Monthly Surveillance Observations, Emergency Svc Water Pump Operability & Oyster Creek Drawing IR 05000219/19890111989-07-25025 July 1989 Insp Rept 50-219/89-11 on 890606-08.Major Areas Inspected: Emergency Preparedness Insp of full-participation Exercise of Licensee Emergency Plan Conducted on 890607.Exercise Did Not Meet Requirements for Annual Test of Emergency Plan IR 05000219/19890121989-07-21021 July 1989 Insp Rept 50-219/89-12 on 890430-0603.Violations Noted.Major Areas Inspected:Plant Operational Events Including Three Reactor Startups & Licensee Corrective Actions Re Reactor Coolant Pressure Boundary Hangers Being Pinned 1999-03-04
[Table view] Category:INSPECTION REPORT
MONTHYEARIR 05000219/19980121999-03-0404 March 1999 Insp Rept 50-219/98-12 During Periods 981214-18,990106-07 & 20-22.No Violations Identified.Major Areas Inspected: Review of Licensee self-assessment of Plant Environ Qualification Program & Corrective Actions for Open Items IR 05000219/19980091998-11-25025 November 1998 Insp Rept 50-219/98-09 on 980914-1025.Violations Noted. Major Areas Inspected:Operations,Engineering,Maintenance & Plant Support IR 05000219/19980081998-10-20020 October 1998 Insp Rept 50-219/98-08 on 980727-0913.No Violations Noted. Major Areas Inspected:Licensee Operations,Engineering,Maint & Plant Support IR 05000219/19980051998-08-26026 August 1998 Insp Rept 50-219/98-05 on 980614-0726.No Violations Noted. Major Areas Inspected:Plant Operations,Maint,Engineering & Plant Support IR 05000219/19980071998-07-0202 July 1998 Insp Rept 50-219/98-07 on 980615-19.No Violations Noted. Major Areas Inspected:Status of Plant motor-operated Valve Program to Determine Acceptability for Closure of NRC Review Under GL 89-10 ML20217F6641998-04-22022 April 1998 Insp Rept 50-219/98-80 on 980223-0313 & 0330-0402.Violations Noted.Major Areas Inspected:Engineering ML20216H1911998-04-15015 April 1998 Insp Rept 50-219/98-04 on 980226-0318.Violations Noted.Major Areas Inspected:Operations,Maint & Plant Support IR 05000219/19970081997-12-0404 December 1997 Insp Rept 50-219/97-08 on 971020-24.No Violations Noted. Major Areas Inspected:Onsite Emergency Plan IR 05000219/19970041997-07-29029 July 1997 Insp Rept 50-219/97-04 on 970526-0706.Violations Noted. Major Areas Inspected:Aspects of Licensee Operations, Engineering,Maint & Plant Support IR 05000219/19970051997-07-17017 July 1997 Insp Rept 50-219/97-05 on 970407-11.No Violations Noted. Major Areas Inspected:Engineering ML20141G9431997-07-0303 July 1997 Insp Rept 50-219/97-03 on 970414-0525.Violations Noted.Major Areas Inspected:Operations,Maint,Engineering & Plant Support IR 05000219/19970021997-05-19019 May 1997 Insp Rept 50-219/97-02 on 970224-0413.Violations Noted. Major Areas Inspected:Operations,Engineering,Maintenance & Plant Support ML20137E9491997-03-21021 March 1997 Insp Rept 50-219/97-01 on 970113-0223.Violations Noted.Major Areas Inspected:Licensee Operations,Engineering,Maint & Plant Support IR 05000219/19960101996-09-27027 September 1996 Insp Rept 50-219/96-10 on 960923-27.No Violations Noted. Major Areas Inspected:Radiological Source Term Assessment, Results of Exposure Reduction Initiatives & Evidence of Station ALARA Program IR 05000219/19960111996-01-0202 January 1996 Insp Rept 50-219/96-11 on 961021-1201.Violations Noted.Major Areas Inspected:Licensee Operations,Engineering,Maint & Plant Support IR 05000219/19930811993-12-22022 December 1993 Insp Rept 50-219/93-81 on 930927-1015.Violations Noted.Major Areas Inspected:Engineering,Maint,Surveillance & Mgt & Corrective Actions IR 05000219/19930261993-11-18018 November 1993 Insp Rept 50-219/93-26 on 931101-05.No Violations Noted. Major Areas Inspected:Mgt Support,Security Program Plans & Audits,Protected & Vital Area Access Control of Personnel & Packages & Vehicles IR 05000219/19930241993-11-18018 November 1993 Insp Rept 50-219/93-24 on 930921-1101.Violations Noted.Major Areas Inspected:Plant Operations,Maint,Engineering,Plant Support,Including Security & Emergency Preparedness & Safety Assessment/Quality Verification ML20058A3791993-11-12012 November 1993 Insp Rept 50-219/93-23 on 931018-20.Onsite Response to Exercise Scenario Was Good.Major Areas inspected:full- Participation Ingestion Pathway Emergency Preparedness Exercise IR 05000219/19930251993-11-0909 November 1993 Insp Rept 50-219/93-25 on 931018-22.No Violations Noted. Major Areas Inspected:Design Mods & Engineering Support ML20059F6251993-10-28028 October 1993 Insp Rept 50-219/93-22 on 930920-24.No Violations Noted. Major Areas Inspected:Addressed Open Items Associated W/Eop & Reviewed Licensee Actions in Response to Violations Associated W/Recirculation Loop Isolation Event IR 05000219/19930181993-10-28028 October 1993 Insp Rept 50-219/93-18 on 930823-1020.No Violations Noted. Major Areas Inspected:Alara,Rirs,Qa Audits,Air & Swipe Sample Counting Facilities & Radiological Controls Organization Professional Staffing IR 05000219/19930201993-10-19019 October 1993 Insp Rept 50-219/93-20 on 930816-930917.No Violations Noted. Major Areas Inspected:Radioactive Liquid & Gaseous Effluent Control Programs Including Mgt Controls & QA Audits IR 05000219/19930211993-10-15015 October 1993 Insp Rept 50-219/93-21 on 930810-0920.No Violations Noted. Major Areas Inspected:Operations,Maint,Engineering,Plant Support & Safety Assessment/Quality Verification IR 05000219/19930111993-09-10010 September 1993 Insp Rept 50-219/93-11 on 930629-0809.No Violations Noted. Major Areas Inspected:Day Shift & Back Shift Hours of Station Activities IR 05000219/19930191993-09-0909 September 1993 Insp Rept 50-219/93-19 on 930816-20.Violations Noted.Major Areas Inspected:Radiological Environ Monitoring Program & Meteorological Monitoring Program IR 05000219/19930141993-09-0202 September 1993 EP Insp Rept 50-219/93-14 on 930802-05.Concerns Noted. Major Areas Inspected:Epip,Equipment,Instrumentation & Supplies IR 05000219/19930161993-08-27027 August 1993 Insp Rept 50-219/93-16 on 930726-30.Major Areas Inspected: Erosion/Corrosion Insp Program,Per GL 89-08.Program & Program Implementation Generally Good.Staff Responsible for Program Development & Implementation Qualified IR 05000219/19930121993-08-26026 August 1993 Insp Rept 50-219/93-12 on 930706-09.No Violations Noted. Major Areas Inspected:Licensee Progress in Incorporating EQ Component Info Into GMS2 Computer Database IR 05000219/19920221993-03-19019 March 1993 Mobile NDE Lab Insp 50-219/92-22 on 921207-11 & 930111-15. No Violations Noted.Major Areas Inspected:Cs,Css,Sdc,Ms & FW Sys IR 05000219/19920251993-02-10010 February 1993 Insp Rept 50-219/92-25 on 921215-930118.Violations Noted. Major Areas Inspected:Plant Operations,Radiological Control, Maint & Surveillance,Engneering & Technical Support, Emergency Preparedness & Security IR 05000219/19930011993-01-29029 January 1993 Insp Rept 50-219/93-01 on 930104-08.No Radiological Safety Concerns or Violations Noted.Major Areas Inspected:Postings & Other in Plant Radiological Controls,Work in Progress, Housekeeping & Self Reading Dosimeter Use IR 05000219/19920231992-12-24024 December 1992 Insp Rept 50-219/92-23 on 921103-1214.No Violations Noted. Major Areas Inspected:Plant Operations,Security & Safety Assessment/Quality Verification IR 05000219/19910041991-03-0101 March 1991 Partially Withheld Insp Rept 50-219/91-04 on 910204-07.No Violations Noted.Major Areas Inspected:Protected Area Physical Barriers,Isolation Zones & Lighting,Protected Area Access Control of Personnel & Security Training IR 05000219/19900191990-11-16016 November 1990 Insp Rept 50-219/90-19 on 900923-1020.Violations Noted. Areas Inspected:Radiological Protection,Surveillance & Maintenance,Emergency Preparedness,Security,Engineering & Technical Support & Safety Assessment/Quality Verification IR 05000219/19900201990-11-0202 November 1990 Insp Rept 50-219/90-20 on 901022-26.No Violations Noted. Major Areas Inspected:Internal Exposure Control & Review of Procedures for Drywell Occupancy During Fuel Movement IR 05000219/19900161990-10-18018 October 1990 Insp Rept 50-219/90-16 on 900823-0922.Violations Noted.Major Areas Inspected:Observation of Plant Activities,Review of Operational Events,Operation of Turbine Bldg Ventilation Sys & Walkdown of Emergency Diesel Fuel Oil Transfer Sys ML20058F3241990-10-0202 October 1990 Insp Rept 50-219/90-17 on 900918-21.No Violations Noted. Major Areas Inspected:Transportation & Solid Radwaste Programs IR 05000219/19900151990-09-20020 September 1990 Partially Withheld Safeguards Insp Rept 50-219/90-15 on 900820-24 (Ref 10CFR73.21).No Violations Noted.Major Areas Inspected:Support,Security Program Plans,Audits,Protected & Vital Areas Physical Barriers,Power Supply & Testing IR 05000219/19900111990-08-15015 August 1990 Insp Rept 50-219/90-11 on 900610-0711.Noncited Violation Noted.Major Areas Inspected:Observation & Review of Plant Operations,Review of Radiological Controls & Routine Observations of Maint Activities & Surveillance Tests ML20056A6191990-07-19019 July 1990 Insp Rept 50-219/90-09 on 900422-0609.Violations Noted. Major Areas Inspected:Observation & Review of Routine Plant Activities & Operational Events,Site Radiological Controls & Events & Observations of Corrective Maint Activities IR 05000219/19890291990-02-16016 February 1990 Insp Rept 50-219/89-29 on 891203-900106.Major Areas Inspected:Observation & Review of Plant Operational Events, Condenser Vacuum Transient,Unusual Events Due to Low Intake Water Level & Simultaneous Movement of Two Control Rods IR 05000219/19890181989-09-13013 September 1989 Insp Rept 50-219/89-18 on 890724-28.No Violations Noted. Major Areas Inspected:Review of Licensee Actions on Previous NRC Concerns,Atws Rule Implementation,Procurement Control & non-licensed Operators Training IR 05000219/19890201989-09-0707 September 1989 Insp Rept 50-219/89-20 on 890829-30.No Exercise Weaknesses Noted.Major Areas Inspected:Licensee Emergency Preparedness Exercise Conducted on 890829-30 ML20246J6261989-08-18018 August 1989 Insp Rept 50-219/89-16 on 890702-29.Violations Noted.Major Areas Inspected:Plant Operational Events,Control of High Radiation Areas,Evaluation of Plant Operation W/High Canal Water Temps & Security Response to Vital Area Door Problem IR 05000219/19890191989-08-15015 August 1989 Insp Rept 50-219/89-19 on 890802-04.No Violations or Deviations Noted.Major Areas Inspected:Solid Radwaste Sys & Transportation Programs,Including Mgt Controls,Audits,Qa & Implementation of Subj Programs IR 05000219/19890151989-08-0909 August 1989 Insp Rept 50-219/89-15 on 890627-30.No Violations Noted. Major Areas Inspected:Organization & Qualifications of Radiological Controls Personnel in Site Organization IR 05000219/19890141989-08-0303 August 1989 Insp Rept 50-219/89-14 on 890604-0701.No Violations Noted. Major Areas Inspected:Core Spray Booster Pump Trips,Under Voltage Relay Failure,Monthly Surveillance Observations, Emergency Svc Water Pump Operability & Oyster Creek Drawing IR 05000219/19890111989-07-25025 July 1989 Insp Rept 50-219/89-11 on 890606-08.Major Areas Inspected: Emergency Preparedness Insp of full-participation Exercise of Licensee Emergency Plan Conducted on 890607.Exercise Did Not Meet Requirements for Annual Test of Emergency Plan IR 05000219/19890121989-07-21021 July 1989 Insp Rept 50-219/89-12 on 890430-0603.Violations Noted.Major Areas Inspected:Plant Operational Events Including Three Reactor Startups & Licensee Corrective Actions Re Reactor Coolant Pressure Boundary Hangers Being Pinned 1999-03-04
[Table view] Category:UTILITY
MONTHYEARIR 05000219/19900201990-11-0202 November 1990 Insp Rept 50-219/90-20 on 901022-26.No Violations Noted. Major Areas Inspected:Internal Exposure Control & Review of Procedures for Drywell Occupancy During Fuel Movement IR 05000219/19900161990-10-18018 October 1990 Insp Rept 50-219/90-16 on 900823-0922.Violations Noted.Major Areas Inspected:Observation of Plant Activities,Review of Operational Events,Operation of Turbine Bldg Ventilation Sys & Walkdown of Emergency Diesel Fuel Oil Transfer Sys IR 05000219/19900111990-08-15015 August 1990 Insp Rept 50-219/90-11 on 900610-0711.Noncited Violation Noted.Major Areas Inspected:Observation & Review of Plant Operations,Review of Radiological Controls & Routine Observations of Maint Activities & Surveillance Tests ML20056A6191990-07-19019 July 1990 Insp Rept 50-219/90-09 on 900422-0609.Violations Noted. Major Areas Inspected:Observation & Review of Routine Plant Activities & Operational Events,Site Radiological Controls & Events & Observations of Corrective Maint Activities IR 05000219/19890291990-02-16016 February 1990 Insp Rept 50-219/89-29 on 891203-900106.Major Areas Inspected:Observation & Review of Plant Operational Events, Condenser Vacuum Transient,Unusual Events Due to Low Intake Water Level & Simultaneous Movement of Two Control Rods IR 05000219/19890181989-09-13013 September 1989 Insp Rept 50-219/89-18 on 890724-28.No Violations Noted. Major Areas Inspected:Review of Licensee Actions on Previous NRC Concerns,Atws Rule Implementation,Procurement Control & non-licensed Operators Training IR 05000219/19890201989-09-0707 September 1989 Insp Rept 50-219/89-20 on 890829-30.No Exercise Weaknesses Noted.Major Areas Inspected:Licensee Emergency Preparedness Exercise Conducted on 890829-30 ML20246J6261989-08-18018 August 1989 Insp Rept 50-219/89-16 on 890702-29.Violations Noted.Major Areas Inspected:Plant Operational Events,Control of High Radiation Areas,Evaluation of Plant Operation W/High Canal Water Temps & Security Response to Vital Area Door Problem IR 05000219/19890191989-08-15015 August 1989 Insp Rept 50-219/89-19 on 890802-04.No Violations or Deviations Noted.Major Areas Inspected:Solid Radwaste Sys & Transportation Programs,Including Mgt Controls,Audits,Qa & Implementation of Subj Programs IR 05000219/19890151989-08-0909 August 1989 Insp Rept 50-219/89-15 on 890627-30.No Violations Noted. Major Areas Inspected:Organization & Qualifications of Radiological Controls Personnel in Site Organization IR 05000219/19890141989-08-0303 August 1989 Insp Rept 50-219/89-14 on 890604-0701.No Violations Noted. Major Areas Inspected:Core Spray Booster Pump Trips,Under Voltage Relay Failure,Monthly Surveillance Observations, Emergency Svc Water Pump Operability & Oyster Creek Drawing IR 05000219/19890111989-07-25025 July 1989 Insp Rept 50-219/89-11 on 890606-08.Major Areas Inspected: Emergency Preparedness Insp of full-participation Exercise of Licensee Emergency Plan Conducted on 890607.Exercise Did Not Meet Requirements for Annual Test of Emergency Plan IR 05000219/19890131989-06-15015 June 1989 Insp Rept 50-219/89-13 on 890522-26.No Violations Noted. Major Areas Inspected:Licensee Liquid & Gaseous Radioactive Effluent Control Programs & Radiological Environ Monitoring Program IR 05000219/19890101989-05-24024 May 1989 Insp Rept 50-219/89-10 on 890402-29.No Violations Noted. Major Areas Inspected:Action of Plant Deficiencies Discovered During Startup,Instrument Air Sys Problems, Surveillance Testing & Control Rod Scram Timing Testing IR 05000219/19890071989-05-17017 May 1989 Insp Rept 50-219/89-07 on 890226-0401.No Violations Noted. Major Areas Inspected:Activities in Progress at Completion of Outage,In Preparation for Startup & Plant Startup Activities IR 05000219/19890061989-05-10010 May 1989 Insp Repts 50-219/89-06 on 890217-24.Violations Noted.Major Areas Inspected:Review of Preliminary Safety Concern Process Including Concerns Involving Standby Gas Treatment Sys, Automatic Depressurization Sys & Containment Spray Sys IR 05000219/19890081989-04-28028 April 1989 Insp Rept 50-219/89-08 on 890313-17.No Violations Noted. Major Areas Inspected:Implementation of Relief & Safety Valve Position Indication Sections of NUREG-0737 & Procedures Re Handling of Emergency Diesel Generator Fuel IR 05000219/19890041989-04-14014 April 1989 Insp Rept 50-219/89-04 on 890115-0225.Violations Noted.Major Areas Inspected:Activities in Progress,Including Air Accumulator Testing,Environ Qualification,Reactor Pressure Vessel Testing,Operations & Physical Security IR 05000219/19882031989-03-13013 March 1989 SSOMI Rept 50-219/88-203 on 881128-1216.Major Areas Inspected:Adequacy of Licensee Mgt & Control of Mods Performed During Major Plant Outage & to Identify Strengths & Weaknesses in Licensee Mod Programs ML20236A5571989-03-0303 March 1989 Safety Insp Rept 50-219/89-03 on 890117-20.No Violations, Deviations or Unresolved Items Noted.Major Areas Inspected: Licensee Emergency Preparedness Program ML20245H9681989-02-21021 February 1989 Insp Rept 50-219/88-38 on 881204-890114.No Violations Noted. Unresolved Items Observed.Major Areas Inspected:Maint & Surveillance Activities,Radiation Control & Physical Security,Including Security Events Re Unauthorized Entry ML20235H2681989-02-0303 February 1989 Insp Rept 50-219/89-02 on 890117-20.Violations Noted.Major Areas Inspected:Licensee Activity Re Info Notice 86-053 (Raychem Splices) IR 05000219/19880311988-11-29029 November 1988 Insp Rept 50-219/88-31 on 881003-07,20 & 1031-1104. Violations Noted.Major Areas Inspected:Status of Outstanding Items,Radiological Controls Re 12R Refueling Outage & Review of Circumstances Concerning Radioactive Spill Incident IR 05000219/19880321988-11-28028 November 1988 Insp Rept 50-219/88-32 on 881017-21.Violation Noted.Major Areas Inspected:Mgt Support,Security Program Plans,Audits, Protected & Vital Area Physical Barriers,Access Control, Detection & Assessment Aids,Testing & Maint & Power Supply IR 05000219/19880281988-11-15015 November 1988 Insp Rept 50-219/88-28 on 880911-1004 & 1014-29.Apparent Violation Noted.Major Areas Inspected:Activities in Progress,Including Plant Operations,Radiation Control, Physical Security,Maint & Forced Shutdown Activities ML20206D0131988-11-0101 November 1988 Environ Qualification Enforcement Conference Rept 50-219/85-39 on 881020.Major Areas Discussed:Significance of Concerns Re Environ Qualification of PVC Tape Splices & Limit Switches Associated W/Msivs.Related Info Encl ML20205P6101988-10-31031 October 1988 Insp Rept 50-219/88-30 on 880929.Notice of Violation Withdrawn.Major Areas Inspected:Emergency Preparedness Activities Re Licensee Response to Notice of Violation & Inspector Followup Items IR 05000219/19880801988-10-28028 October 1988 Augmented Insp Team Rept 50-219/88-80 on 881005-13.Major Areas Inspected:Circumstances Surrounding Steaming Phenomenon on Both Isolation Condensers in Late Aug & Sept 1988 & Electrical Fault on Diesel Generator 2 on 881002 IR 05000219/19880291988-10-22022 October 1988 Insp Rept 50-219/88-29 on 880914-15.App R Violation Re High & Low Pressure Interface During Design Basis Fire Which Could Cause Loss of Reactor Coolant Noted.Major Areas Inspected:Interviews W/Personnel & Inspector Observations ML20205J7301988-10-11011 October 1988 Insp Rept 50-219/88-26 on 880909 & 0912-15.No Violations Noted.Major Areas Inspected:Licensee Inservice Insp Program to Ascertain That Program Complies W/Applicable ASME Code & Regulatory Requirements & Response to Generic Ltr 88-01 ML20207N2331988-10-0404 October 1988 Insp Rept 50-219/88-25 on 880829-0902.No Violations Noted. Major Areas Inspected:Licensee Actions in Response to NRC Bulletins 79-02 & 79-14,Deficiencies Noted in Some Pipe Support & Pipe Support Base Plates IR 05000219/19880231988-09-27027 September 1988 Insp Rept 50-219/88-23 on 880731-0910.Violation Noted. Major Areas Inspected:Plant Operations & Startup,Radiation Control,Physical Security,Maint & Forced Shutdown Work Activities & Isolation Condenser Sys Operability IR 05000219/19880241988-09-0909 September 1988 Insp Rept 50-219/88-24 on 880715 & 18-0812.No Violation Noted.Unresolved Item Identified.Major Areas Inspected: Failure of MSIV NS03A Stem,Including Sequence of Events, Maint & Surveillance Test History & Stem Matl ML20151Y3081988-08-15015 August 1988 Insp Rept 50-219/88-15 on 880523-0726.Violations Noted. Major Areas Inspected:Licensee Action in Response to Mark I Containment Mod Requirements of NUREG-0661,review of Design Analyses & Plant Unigue Analysis Rept IR 05000219/19880221988-08-12012 August 1988 Insp Rept 50-219/88-22 on 880718-22.No Violations Noted. Major Areas Inspected:Gaseous & Liquid Radioactive Effluent Control Programs,Licensee Action on Previous Insp Findings, Effluents,Instrumentation,Audits & Air Cleaning Sys IR 05000219/19880171988-07-26026 July 1988 Insp Rept 50-219/88-17 on 880613-17.No Violations Noted. Major Areas Inspected:Previously Identified Findings,Spds & Planned Mods to Institute Corrective Measures to Satisfy ATWS IR 05000219/19880181988-07-11011 July 1988 Mgt Meeting Rept 50-219/88-18 on 880609.Major Areas Discussed:Status of Licensee Action/Plans & Schedules for Work Per IE Bulletins 79-02 & 79-14 IR 05000219/19880121988-07-0808 July 1988 Insp Rept 50-219/88-12 on 880425-29.No Violations Noted. Major Areas Inspected:Review of Licensee Program Implementation of 10CFR21 Regulation & Review of Station Procurement Program IR 05000219/19880051988-06-30030 June 1988 Insp Rept 50-219/88-05 on 880511-12.No Violations Noted. Major Areas Inspected:Emergency Exercise Conducted on 880511-12 IR 05000219/19880141988-06-27027 June 1988 Insp Rept 50-219/88-14 on 880516-20.Violation Noted.Major Areas Inspected:Selected Areas of Fire Protection & Electric Power Sys,Including Reviews of Administrative Control, Surveillance & Fire Brigade Procedures IR 05000219/19880131988-06-14014 June 1988 Insp Rept 50-219/88-13 on 880424-0521.One Violation Noted. Major Areas Inspected:Plant Operations,Physical Security, Radiation Control,Housekeeping,Fire Protection & Emergency Preparedness & Annual Emergency Exercise Participation IR 05000219/19880091988-05-26026 May 1988 Insp Rept 50-219/88-09 on 880320-0423.No Violations Noted. Major Areas Inspected:Plant Operations,Radiation Control, Physical Security,Surveillance,Maint & Environ Qualification Files for Reactor Vessel Pressure Switches IR 05000219/19880111988-05-11011 May 1988 Safety Insp Rept 50-219/88-11 on 880411-15.Violations Noted. Major Areas Inspected:Status of Items Identified During 1987 Integrated Performance Assessment Team Insp & Status of Measures to Control Drywell Access IR 05000219/19880041988-05-0606 May 1988 Insp Rept 50-219/88-04 on 880207-0319.Violations Noted.Major Areas Inspected:Activities in Progress,Including Plant Operation,Physical Security,Radiation Control,Housekeeping, Fire Protection & Emergency Preparedness ML20153D8181988-04-29029 April 1988 Insp Rept 50-219/88-06 on 880222-26.Violation Noted.Major Areas Inspected:Emergency Implementing Procedures & Plans, Emergency Facilities,Equipment,Instrumentation & Supplies & Application of IE Info Notices 83-28 & 84-80 IR 05000219/19880081988-04-29029 April 1988 Mgt Meeting Rept 50-219/88-08 on 880308.Major Areas Discussed:Licensee Activities Re NRC Bulletins 79-02 & 79-14.Licensee Presentation Encl IR 05000219/19870421988-03-14014 March 1988 Insp Rept 50-219/87-42 on 871220-880206.No Violations Noted. Major Areas Inspected:Activities in Progress,Including Operations,Radiation Control,Physical Security,Surveillance & Maint IR 05000219/19880021988-02-29029 February 1988 Insp Rept 50-219/88-02 on 880125-29.Violations Noted.Major Areas Inspected:Safety Implications of Freezing Conditions Identified in Reactor Bldg on 880106 & Effectivness of Licensee Corrective Measures IR 05000219/19880011988-02-19019 February 1988 Insp Rept 50-219/88-01 on 880104-08.No Violations or Deviations Noted.Major Areas Inspected:Licensee Actions on Previously Identified NRC Concerns,Util Offsite Review Committee & Organization & Administration & QA Audits IR 05000219/19870401988-01-21021 January 1988 Physical Security Insp Rept 50-219/87-40 on 871106.No Violations Noted.Major Areas Inspected:Three Allegations Re Deficiencies in Security Program.Allegations Were Not Substantiated 1990-08-15
[Table view] Category:TEXT-INSPECTION & AUDIT & I&E CIRCULARS
MONTHYEARPNO-I-99-043, on 990916,Hurricane Floyd Was Approaching Ccnpp,Sgs,Hcgs & Ocnpp.Hurricane Was Centered at Latitude 36.0 North & Longitude 76.6 West & Moving north-northeast at Approx 25 Mph.Plants Remain at Power1999-09-16016 September 1999 PNO-I-99-043:on 990916,Hurricane Floyd Was Approaching Ccnpp,Sgs,Hcgs & Ocnpp.Hurricane Was Centered at Latitude 36.0 North & Longitude 76.6 West & Moving north-northeast at Approx 25 Mph.Plants Remain at Power IR 05000219/19980121999-03-0404 March 1999 Insp Rept 50-219/98-12 During Periods 981214-18,990106-07 & 20-22.No Violations Identified.Major Areas Inspected: Review of Licensee self-assessment of Plant Environ Qualification Program & Corrective Actions for Open Items IR 05000219/19980091998-11-25025 November 1998 Insp Rept 50-219/98-09 on 980914-1025.Violations Noted. Major Areas Inspected:Operations,Engineering,Maintenance & Plant Support ML20196C6071998-11-25025 November 1998 Notice of Violation from Insp on 980914-1025.Violation Noted:On 981014,security Force Vehicle Escort Left Non licensee-designated Vehicle Unattended in Protected Area & Failed to Ensure That Vehicle Ignition Locked & Key Removed IR 05000219/19980081998-10-20020 October 1998 Insp Rept 50-219/98-08 on 980727-0913.No Violations Noted. Major Areas Inspected:Licensee Operations,Engineering,Maint & Plant Support IR 05000219/19980051998-08-26026 August 1998 Insp Rept 50-219/98-05 on 980614-0726.No Violations Noted. Major Areas Inspected:Plant Operations,Maint,Engineering & Plant Support IR 05000219/19980991998-07-17017 July 1998 SALP Rept 50-219/98-99 for 961201-980613 IR 05000219/19980071998-07-0202 July 1998 Insp Rept 50-219/98-07 on 980615-19.No Violations Noted. Major Areas Inspected:Status of Plant motor-operated Valve Program to Determine Acceptability for Closure of NRC Review Under GL 89-10 ML20249B3661998-06-15015 June 1998 Notice of Violation & Proposed Imposition of Civil Penalty in Amount of $55,000.Violation Noted:Prior to 980304, Licensee Failed to Establish Adequate Design Control Measures to Verify Adequacy of Design Voltage ML20237E4491998-06-10010 June 1998 EN-98-047:on 980615,notice of Proposed Imposition of Civil Penalty in Amount of $55,000 Issued to Licensee.Action Based on Severity Level III Problem Involving Inoperability of Three of Five Automatic Depressurization Valves ML20217F6641998-04-22022 April 1998 Insp Rept 50-219/98-80 on 980223-0313 & 0330-0402.Violations Noted.Major Areas Inspected:Engineering ML20217F6491998-04-22022 April 1998 Notice of Violation from Insp on 980223-0313 & 0330-0402. Violations Noted:On 980226,seismic Deficiency W/Containment Spray Heat Exchanger,That Had Been Identified in Late 1996 by Licensee,Had Not Been Adequately Corrected ML20216H1911998-04-15015 April 1998 Insp Rept 50-219/98-04 on 980226-0318.Violations Noted.Major Areas Inspected:Operations,Maint & Plant Support ML20216H1701998-04-15015 April 1998 Notice of Violation from Insp on 980226-0318.Violations Noted:Since Initial Plant Operation,Operators Implemented Procedure 307,isolation Condenser Sys,Permitting Fill & Make Up to Isolation Condensers During Normal Plant Operations ML20216J0181998-04-14014 April 1998 Notice of Violation from Insp on 971229-980208.Violation Noted:Written SE Was Not Performed to Provide Bases for Determination That Change in Facility as Described in SAR Did Not Involve USQ IR 05000219/19970081997-12-0404 December 1997 Insp Rept 50-219/97-08 on 971020-24.No Violations Noted. Major Areas Inspected:Onsite Emergency Plan ML20199G7881997-11-17017 November 1997 Notice of Violation from Insp on 970707-970824.Violation Noted:In Oct 1993,vendor Specification for Emergency Svc Water Pump Bowl Assemblies Was Changed from Cast Iron to Stainless Steel PNO-I-97-045, on 970801,electricians Restoring One Set of Main Generator Exciter Brushes,Following Routine Surveillance,When One of Brushes Sparked Excessively & Disintegrated.Electricians Exited Area & Notified CR1997-08-0404 August 1997 PNO-I-97-045:on 970801,electricians Restoring One Set of Main Generator Exciter Brushes,Following Routine Surveillance,When One of Brushes Sparked Excessively & Disintegrated.Electricians Exited Area & Notified CR IR 05000219/19970041997-07-29029 July 1997 Insp Rept 50-219/97-04 on 970526-0706.Violations Noted. Major Areas Inspected:Aspects of Licensee Operations, Engineering,Maint & Plant Support IR 05000219/19970051997-07-17017 July 1997 Insp Rept 50-219/97-05 on 970407-11.No Violations Noted. Major Areas Inspected:Engineering ML20141G9431997-07-0303 July 1997 Insp Rept 50-219/97-03 on 970414-0525.Violations Noted.Major Areas Inspected:Operations,Maint,Engineering & Plant Support ML20141G9401997-07-0303 July 1997 Notice of Violation from Insp on 970414-0525.Violation Noted:On 970423,CROs Placed a & B Loops of Shutdown Cooling Sys in Svc W/O Placing Suction Pressure Interlocks in Svc for a & B Pumps by Opening Ps Isolation Valves IR 05000219/19970021997-05-19019 May 1997 Insp Rept 50-219/97-02 on 970224-0413.Violations Noted. Major Areas Inspected:Operations,Engineering,Maintenance & Plant Support ML20141J5221997-05-19019 May 1997 Notice of Violation from Insp on 970224-0413.Violation Noted:Permanent Change,Dec 95,made to Facility,As Described in SAR Involving Removal of Isolation Condenser Radiation Monitors W/O Considering All Relevant Portions of SAR PNO-I-97-024, on 970422,Oyster Creek Nuclear Generating Station Commenced Controlled Shutdown of Unit Due to Equipment Problems.Unit Expected to Be Shut Down for Six Days for Correction of Diaphram Problem1997-04-23023 April 1997 PNO-I-97-024:on 970422,Oyster Creek Nuclear Generating Station Commenced Controlled Shutdown of Unit Due to Equipment Problems.Unit Expected to Be Shut Down for Six Days for Correction of Diaphram Problem PNO-I-97-022, on 970410,GPU,Inc Announced,Addition to Continued Operation of Oyster Creek & Also Exploring Options of Sale.Util Will Begin Next Wk to Develop Plans to Support Sale of Plant,Decommissioning & Personnel Retention1997-04-10010 April 1997 PNO-I-97-022:on 970410,GPU,Inc Announced,Addition to Continued Operation of Oyster Creek & Also Exploring Options of Sale.Util Will Begin Next Wk to Develop Plans to Support Sale of Plant,Decommissioning & Personnel Retention ML20137E9411997-03-21021 March 1997 Notice of Violation from Insp on 970113-0223.Violation Noted:Procedure 108.7, Lockout/Tagout Procedure, Rev 4, Did Not Include Appropriate Quantitative or Qualitative Acceptance Criteria ML20137E9491997-03-21021 March 1997 Insp Rept 50-219/97-01 on 970113-0223.Violations Noted.Major Areas Inspected:Licensee Operations,Engineering,Maint & Plant Support IR 05000219/19960991997-01-0909 January 1997 SALP Rept 50-219/96-99 for Oyster Creek Nuclear Generating Station for 950625-961130 ML20133D6781997-01-0202 January 1997 Notice of Violation from Insp on 961021-1201.Violation Noted:Written Safety Evaluation Was Not Performed to Provide Bases for Determination That Change to Station Procedure 336.3 Did Not Involve Unreviewed Safety Question PNO-I-96-078, on 961025,licensee Manually Scrammed Reactor Due to Turbine Runback,Resulted from Problem in Stator Cooling Sys.Resident Will Continue to Follow Event1996-10-29029 October 1996 PNO-I-96-078:on 961025,licensee Manually Scrammed Reactor Due to Turbine Runback,Resulted from Problem in Stator Cooling Sys.Resident Will Continue to Follow Event IR 05000219/19960101996-09-27027 September 1996 Insp Rept 50-219/96-10 on 960923-27.No Violations Noted. Major Areas Inspected:Radiological Source Term Assessment, Results of Exposure Reduction Initiatives & Evidence of Station ALARA Program IR 05000219/19960111996-01-0202 January 1996 Insp Rept 50-219/96-11 on 961021-1201.Violations Noted.Major Areas Inspected:Licensee Operations,Engineering,Maint & Plant Support IR 05000219/19920991994-01-26026 January 1994 SALP Rept 50-219/92-99 for Period 920719-931211 ML20059B6331993-12-23023 December 1993 Notice of Violation from Insp on 930927-1015.Violation Noted:All NRC Violations & Ten Licensee Event Repts Issued in 1992 & 1993 Did Not Receive Required Independent Safety Reviews IR 05000219/19930811993-12-22022 December 1993 Insp Rept 50-219/93-81 on 930927-1015.Violations Noted.Major Areas Inspected:Engineering,Maint,Surveillance & Mgt & Corrective Actions IR 05000219/19930261993-11-18018 November 1993 Insp Rept 50-219/93-26 on 931101-05.No Violations Noted. Major Areas Inspected:Mgt Support,Security Program Plans & Audits,Protected & Vital Area Access Control of Personnel & Packages & Vehicles IR 05000219/19930241993-11-18018 November 1993 Insp Rept 50-219/93-24 on 930921-1101.Violations Noted.Major Areas Inspected:Plant Operations,Maint,Engineering,Plant Support,Including Security & Emergency Preparedness & Safety Assessment/Quality Verification ML20058A3791993-11-12012 November 1993 Insp Rept 50-219/93-23 on 931018-20.Onsite Response to Exercise Scenario Was Good.Major Areas inspected:full- Participation Ingestion Pathway Emergency Preparedness Exercise ML20059M3211993-11-0909 November 1993 EN-93-081A:on 930812,notice of Proposed Imposition of Civil Penalty in Amount of $75,000 Issued to Licensee.Action Based on Five Radiological Controls Violations IR 05000219/19930251993-11-0909 November 1993 Insp Rept 50-219/93-25 on 931018-22.No Violations Noted. Major Areas Inspected:Design Mods & Engineering Support ML20059F6251993-10-28028 October 1993 Insp Rept 50-219/93-22 on 930920-24.No Violations Noted. Major Areas Inspected:Addressed Open Items Associated W/Eop & Reviewed Licensee Actions in Response to Violations Associated W/Recirculation Loop Isolation Event IR 05000219/19930181993-10-28028 October 1993 Insp Rept 50-219/93-18 on 930823-1020.No Violations Noted. Major Areas Inspected:Alara,Rirs,Qa Audits,Air & Swipe Sample Counting Facilities & Radiological Controls Organization Professional Staffing IR 05000219/19930201993-10-19019 October 1993 Insp Rept 50-219/93-20 on 930816-930917.No Violations Noted. Major Areas Inspected:Radioactive Liquid & Gaseous Effluent Control Programs Including Mgt Controls & QA Audits IR 05000219/19930211993-10-15015 October 1993 Insp Rept 50-219/93-21 on 930810-0920.No Violations Noted. Major Areas Inspected:Operations,Maint,Engineering,Plant Support & Safety Assessment/Quality Verification ML20059A2201993-10-15015 October 1993 Notice of Violation from Insp on 920719-0825.Violation Noted:Licensee Determined That Records Required to Be Maintained by Commission Regulations or License Conditions Not Complete & Accurate in All Matl Respects IR 05000219/19930171993-09-14014 September 1993 Exam Rept 50-219/93-17OL on 930810-12.Exam Results:All 16 Licensed Operators Passed All Portions of Exam That Was Administered & All Three Crews Performed Satisfactorily in Simulator ML20149D5021993-09-13013 September 1993 Notice of Violation from Insp on 930629-0809.Violation Noted:On 930709,NRC Identified Condition Adverse to Quality That Had Existed Since 920709 IR 05000219/19930111993-09-10010 September 1993 Insp Rept 50-219/93-11 on 930629-0809.No Violations Noted. Major Areas Inspected:Day Shift & Back Shift Hours of Station Activities ML20149D7051993-09-10010 September 1993 Notice of Violation from Insp on 930816-20.Violation Noted: as of 930820,appropriate Measures Were Not Established to Assure Adequate Quality Was Suitably Included in Documents for Procurement of Svcs 1999-09-16
[Table view] |
See also: IR 05000219/1987012
Text
{{#Wiki_filter:- _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
.
.
U.S. NUCLEAR REGULATORY COMMISSION
REGION I
Report No. 50-219/87-12
Docket No. 50-219
License No. OPR-11 Priority -
Category C
Licensee: GPU Nuclear Corporation
PDox 388
Forked River,_New Jersey 08731
Facility Name: Oyster Creek Nuclear _!tation
Inspection At: Forked River, New Jersey
Inspection Conducted: April 22-24a 27, 1987
Inspectors: . N g!ZO!#7
[ J 781cehouse, Radiation Specialist date
Approved by: e g. N. '
l3F
W. J N a;s,iak,
c Chief / date
Effluents Radiation Protection Section
Inspection Summary:
In_spection on April 22-24, 27, 1987 (Report No. 50-219/87_-12)
Areas Inspecte_d: Special, unannounced safety inspection of solid radioactive
waste preparation, packaging and shipping activities including: previously
identified items, management controls, quality assurance and implementation of
the program. Special emphasis was placed on reviewing a shipment of
solidified filter sludge found to contain free-standing licuid by the South
Carolina Department of Health and Environmental Control.
Results: One violation was identified: failure to provide solid radioactive
waste with less than 1% of the volume as free-standing liquid (Paragraph 6).
%f[0%{{k
0
h
_ ___ __ ___ _ __ _
.
.
Details
1. Persons Contacted
1.1 Licensee Personnel
*J. J. Barton, Deputy Director
K. T. Brown, Quality Assurance (QA) Lead Monitor
A. Erbs, Radiation Controls Technician
*S. H. Fuller, Operations QA Manager
*C, J. Halbfosteg, Manager, Plant Chemistry /Radwaste
*M. Heller, Licensing
R. V. Hurley, Group Radwaste Shipping Supervisor
B. Krechel, Radiation Controls Technician
*M. J. Slobodien, Radiological Controls Manager
*J. L. Sullivan, Jr., Plant Operations Director
*A. H. Wacha, Radwaste Shipping Supervisor
Other licenseo personnel were also contacted or interviewed.
1.2 Contractor Pe_rsonnel
F. Decker, Solidification Technician, Chem Nuclear Services, Inc.
1.3 NRC personnel
*W. H. Bateman, Senior Resident Inspector
*J. F. Wechselberger, Resident Inspector
* denotes attendance at the exit interview on April 27, 1987
2. Scope of the Inspection
This special inspection reviewed the Itcensee's solid radioactive waste
(radwaste) preparation, packaging and shipping program as implemented
by the licensee from August 1, 1985 through April 24, 1987. On Acril 15,
1987, NRC Region I was notified that licensee's shipment No. OC-2003-87
(containing approximately 6.3 curies of total activity) had been found to
contain free-standing liquid in excess of 1?4 of the volume of that ship-
ment by the South Carolina Department of Health and Environmental Control.
The circumstances surrounding this apparent violation of conditions 32.0
and 35 of South Carolina Radioactive Material License No. 97 and NRC
requirements under 10 CFR 20.311 and 10 CFR 61.56 were reviewed. In
addition a review of the licensee's radwaste preparation, packaging and
shipping program was also completed. A sample of the Itcensee's solid
radwaste shipments (including shipment No. OC-2003-87) representing
approximately 15's of the shipments mado during 1986-87 was selected
and reviewed relative to requirements in 10 CFR 20, 61 and 71, 49 CFR
170-189 and licensee Technical Specifications. The sample included
shipments of dry active wastes, resins, evaporator residues and filter
sludge materials. The licensee's actions regarding previously identified
items were also reviewed.
_ _ _ _ _ _ _ _ _ _ _ __ _ _ _ _
.
2
3.0 Previously Identified Items
3.1 (Closed) Violation (50-219/85-25-02) - Waste Generator Quality -
Control Deficiencies
Actions described in the licensee's letter (dated October 17,1985)
regarding deficiencies in the licensee's waste generator quality '
control (QC) program were reviewed. The licensee's Operations
Quality Assurance (QA) group increased monitoring activities
covering radwaste solidification, resin dowatering and waste
classification including increased monitoring of process control
program (PCP) performance, classification computer program review
and independent verification of critical , process calculations and
steps. The actions appeared to have addressed the specific
deficiencies in the QC program as noted in NRC Inspection Report
No. 50-219/85-25. This item is closed.
J.2 (Closed) Follow-up Item (50-219/85-25-03) - Transport package
inclusion in the QA Plan Process
The licensee made changes to the Operational Quality Assurance Plan
(Licensee No.1000-PLN-7200.01) to specifically address control of
radioactive waste shipments and packages. This item is closed.
3.3 (Closed) Follow-up Item (50-219/85-25-04) - Audits of Transportation
-
Activ_itiesToincludeApplicablePortionsofIDCFG0.Aipo^nTITB- ,
QA audits of the licensee's transportation activities conducted in
1985 and 1986 were reviewed to determine if applicable parts of 10
CFR 50, Appendix 0 had been applied to the review of radwaste
preparation, packaging and shipping activities. NRC Regulatory
Guide 7.10 and IE Information Notice No. 84-50 provided the basis
for the review. Audit Report Nos. S-0C-85-13 and S-0C-86-11 were
reviewed and determined to be in general agreement with the
regulatory guidance. This item is closed.
3.4 (Closed) Unresolved Item (50-219/85-25-05) - Labeling Conflicts
The licensee made rev bions to shipping procedures to ensure that
inappropriatevendorlabeling(e.g.,"00T7A"onModel14-195 casks)
would be masked by tape before shipment. In addition, the licensee
discussed the labeling conflicts with the cask vendor and wrote a
letter to the vendor as follow-up. The actions by the licensee '
appeared responsive to the problem noted in Inspection Report No. l
50-219/85-25. This item is closed,
r
.
. - _ - _ _ _ _ _ _
'
.
i
:
'
- l
3
4. Management Controls
I
'
4.1 Organization
The Itcensee's organization was briefly reviewed to determine if L
clear designations of responsibilities were provided for solid
radwaste processing, packaging and shipping activities. Under the
Manager Plant Cnemistry/Radwaste, the Radwaste Shipping Supervisor !
had responsibility for solid radwaste processing, packaging and
shipping activities. The Radwaste Shipping Group, (including Group
Radwaste Shipping Supervisors and Technicians) reported to the Rad-
waste Shipping Supervisor and implemented the program. Radiation
, Controls Technicians in the Radiological Controls group provided ;
surveys of radiation levels and contamination for radwasto processing I
, and shipping activities. Contracted dowatering and solidification
'
servicos were used to process resin, filter sludge and contaminated
oil radwaste materials. Although the contracted services operated
under licensee-approved procedures, technical direction was provided
by an of fsite supervisor, (within the Chem Nuclear Service, Inc.
organization). Prior to April 15, 1987, the Solidification Techni-
clan and the offsite supervisor could change important solidification i
process parameters (e.g., mixing speed) without approval of the licen-
see's solid radwaste organization. This weakness in the control of
'
the contracted dewatering and solidification service contributed to l
4 the problem noted with Shipment No. OC-2003-87. t
!
!
1 Receipt inspections of transport packages and vehicles are the !
i responsibility of the QC inspectors. Operations QA provided '
l monitoring activities as described in paragraph 3.1.
i
j 4.2 Procedures
l The Itconsee's procedures for preparation, packaging and shipping
i solid radwastes were reviewed relative to criteria in Technical
1 Specification 6.8, " Procedures", and regulatory requirements in 10
! CFR 20,311,10 CFR 71 and 49 CFR 170-189. Routino procedures were
'
reviewed to determine if instructions regarding regulatory limits
! and acceptance critoria were provided. The technical bases for
i identification of radionuclides, quantification of activities,
determination of classification under 10 CFR 61.55 and waste form
; under 10 CFR 61.56 and selection of packages for shipment under 10 !
CFR 71 were reviewed and discussed with members of the Radwaste
$ hipping group. Procedures to update the computer database for
scaling factors used to quantifyactivities of hard-to-identify
radionuclidos in the various radwaste streams and to obtain
additional radwaste samples for gross activity changes in Reactor t
Coolant System were also reviewed. No weaknestos were noted in this i
review,
i i
,
I
'
1
I
I
4 (
!
.__ _ __
l-
,.
4
, Hypothetical radwaste sample data provided by the inspector were
l used to test the computer program's capability to determine waste
i
'
class under 10 CFR 61.55, determine waste form under 10 CFR 61.56
and specify packaging under 10 CFR 71. The test showed that the
computer program's algorithms accurately determined waste class,
provided waste form needs and selected appropriate shipping packages
for the test cases.
Vendor dewatering and solidification procedures were reviewed to
determine if appropriate controls and inspection holdpoints were
provided. Process Control Program implementing procedures were
reviewed to determine the test specimens used to provide appropriate
scale solidification control parameters. The inspector noted that
Itcensee-approved vendor procedures, (e.g., Procedure 351.36,
" Processing Radioactive Waste Solid and Liquid Waste by CNSI Cement i
Solidification System,") had " permissive" statements allowing !
operator discretionary changes to key operating parameters such as '
,
mixer speed, number of slurry dewatering cycles, etc. The use of
I the discretionary changes in the mixing speed for Shipment No. OC-
2003-87 contributed to the inadequate mixing and incomplete
l
solidification noted in that shipment.
4.3 Traini.ng r
The training of personnel assigned to radwaste shipping activities
was reviewed relative to revised commitments (see NRC Inspection ,
Report No. 50-219/87-02 regarding NRC Bulletin No. 79-19) reflecting
the licensee's reorganization. Training for the Group Radwaste
Shipping Supervisors, technicians, QC inspectors and Radiological
Controls Technicians was briefly reviewed. Annual inhouse and
offsito training programs were provided. No deviations fron. the
licensee's revised commitments to NRC Bulletin No. 79-19 were noted.
I 5. l
g ujt.Lty_A, slu ra n c e/Qu a l i ty_qo njr_o 1
1
i The provisions of 10 CFR 71, Subpart H require the establishment of a
I
quality assurance (QA) program for the packaging and shipping of radio-
l
active materials. A Commission-approved QA program which satisfies the l
applicable criteria of Appendix 0 to 10 CFR 50 and which is established.
'
l maintained and executed with regard to transport packages is acceptable
to meet the requirements of 10 CFR 71, Subpart H. The licensee elected
l to apply the currently established 10 CFR 50, Appendix 0. OA program to
l the packaging and shipment of radwaste materials.
? i
Specific quality control (0C) requirements to assure compliance with 10
CFR 61.55 waste classification and 10 CFR 61.56 waste form requirements
are required by 10 CFR 20.311 for radwaste generators in addition to the ,
general QC requirements of 10 CFR 50, Appendix 0. The program requires !
Judits and management review of those audits for radwaste generator 1
activities, i
t
!
,
_ . _ _ __.__ _._____..________ _. _.._ _ _ _ _ _ _ . .
__ - - _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ ___ _____ _ _ _ _ _ _ _ _ _ _ __ _ ___
.
5
The implementation of QA/QC activities to the processing, preparation,
packaging and shipment of solid radwastes was reviewed. The inspector
noted that upgrades had been completed to the radwaste generator and
radwaste shipping QA/QC programs (see related items in Detail 3) and site
QA/QC organizations were responsible for implementing all applicable QA l
criteria to the processing, preparation, packaging and shipment of
radwastes including audits of the program.
5.1 Radwaste Generator QC Program [
The Operations QA organization monitors radwaste processing and
preparation. Quality Assurance checklists and monitoring reports
related to shipments of dowatered resins and solidified filter !
sludge radwaste materials were reviewed. The inspector noted that
the monitoring activity included notification by radwaste processors ;
at key stops, independent verification of solidification and dewater-
'
ing, independent verification of calculations used in solidifications
and reviews of computer generated waste classifications.
Licenseo audit reports (Nos. S-0C-85-13 and 5-0C-86-11) were reviewed !
for inclusion of wasto generator requirements and management review i
and resolution of findings.
Within the scope of these reviews, no problems were noted. I
5.2 Radwas_to $hippe d ALQC Program j
As noted in Detail 3, the application of the licensee's QA/QC l
program to shipping activities was reviewed and appeared to meet
applicable NRC regulatory guidance. Implementation of the program ,
to receipt of shipping containers and liners, control of high '
integrity containers, vehicle and package inspections and review of
vendor activities was reviewed for selected shipments of dry active
wasto, dowatered resins and solidified filter sludges and evaporator ;
residues.
7
Within the scope of this review, no problems were noted. !
6. Implementatinn
The implementation of the licensoo's program for processing, preparation, i
packaging and shipping solid radwasto materials was reviewed rotative to i
critoria in 10 CFR 20,311, 10 CFR 71, 49 CFR 172-173 and the licensee's
Technical Specifications and procedures. Each shipment examined was ,
reviewed to determine the adequacy oft ;
-
classification under 10 CFR 20.311 and 10 CFR 61.551 [
waste form under 10 CFR 20.311 and 10 CFR 61.56;
'
-
-
radiation and contamination measuromonts;
-
shipping paper and radwaste manifest documentation;
-
package marking and labeling; i
t
I
,
!
!
___-_____ _ _ _ _ _ _ _ _ _ _ - . . _ _ _ _ ___ ___ -_- __________________-______ _ _ __ ____ _ -___
.
'
. 6
1
- loading and storage of packages;
- conditions of appitcable Certificates of Compliance;
- vehicle placarding; !
- instructions to drivers;
- adherence to disposal site license conditions; and
- nottfication to state agencies (as applicable under 10 CFR 71.97).
The Itcensee hadn't conducted any special radwaste shipments, (e. g.
Irradiated reactor components) during 1986-87. The following table
summarizes the licensee's radwaste shipments:
.
"
!
l Dry Active Filter Evaporator l
!
Year Waste (DAW) Media Residues Resins
!
1986 21 7 7 15
! 1987 (April 15) 3 3 2 2 :
Totals 24 10 9 17 I
f
A total of 9 shipments (~15%) were selected for review representing each l
waste stream and the 3 radwaste classes in 10 CFR 61.55. The following
!
i,
;
list contains the licenseo'sradwaste shipments reviewed:
Shipment No. Description Date
j OC-3002-87 Evaporator residue F17/87
0C-4009-86 Dewatered resin 9/15/86
i) OC-2001-87 FilterSludge(media) 1/29/87
! OC-3004-86 Evaporator residue 7/10/86
'
OC-4001-87 Dewatered resins 1/12/87
i OC-4014-86 Dewatered resins 11/15/86 !
! 0C-4015-86 Dewatered resins 12/17/86 .
1
OC-1022-86 Ory Active Waste 12/30/86 i
OC-2003-87 Filter Media (" sludge") 4/9/87 l
\
! The inspector noted that the licensee maintained radwaste shipping I
! records as " stand-alone" packages, i.e., each shipment's records included
I sufficient information to allow review of each of the regulatory areas
! Itsted above. ,
I
j Within the scope of this review, the fo11owing violation was noted: j
i '
' - 10 CFR 20.311(d)(1) requires, in part, preparation of radwastes to
a
meet waste characteristics requirements in 10 CFR 61.56. 10 CFR
!
i
61.56(a)( 3) requires radwaste containing liquid be converted into a
'
form that contains as little free-standing and noncorrosive Itquid as
!
is reasonable achievable, but in no case shall that 11guld exceed
!
1.0% of the volume for waste processed to a stable form,
i Contrary to the above, Itcensee's shipment No. OC-2003-87,
! (containing approximately 6.3 curies of radioactive metal oxides
!
i processed to a stable form with cement in a steel liner, class A
} under 10 CFR 61.55 and consigned to an " Exclusive Use" shipment on [
' April 9, 1987), was found to contain approximately 49 gallons of i
- !
'
.
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ ___
.
*
. 7
i
free-standing liquid in a total waste shipment volume of 177 cubic
feet, (i.e., 1324 gallons). The free-standing liquid equalled
, approximately 3.7% of the volume of the waste. Upon receipt of the
i
licensee's shipment at the Barnwell, South Carolina disposal site,
; representatives of the burial site operator, (i.e., Chem Nuclear
! Systems, Inc.) and the South Carolina Department of Health and
4 Environmental Control set the steel liner aside for inspection and
testing. Holes were tapped in the liner, free standing liquid was
drained and collected and its volume measured. On April 14, 1987,
4 the South Carolina Department of Health and Environmental Control
informed the licensee that free standing liquid exceeding burial site
'
license conditions and State Regulations. Subsequent measurements of ;
i the volume of free-standinq liquid through April 22, 1987 showed a
total volume of at least 49 gallons had been present in the liner.
i
On April 23, 1987, the South Carolina Department of Health and .
1 Environmental Control issued a violation to the licensee and proposed i
'
a civil penalty of $1,000. Failure to prepare radwaste in Shipment !
;
No. OC-2003-87 with less than 1.0', free-standing liquid constitutes a
violation of 10 CFR 20.311 (d)(1). 50-219/87-12-01.
l
- The inspector reviewed the circumstances surrounding licensee's
< shipment No. OC-2003-87 to determine the apparent causes of the
incomplete solidification. The steel liner containing the filter '
i
! sludge radwaste materials was solidified by a contracted vendor,
l (Chem Nuclear Systems, Inc.) using a process control program dis-
l cussed in Topical Report CNSI-2 (4313-01354-01P-A). However, several
j changes to the process had occurred. Approximately 18 months prior
j to the shipment, foaming problems with evaporator residue solidifi-
! cations had led to a reduction in mixing speed from the 65-85
i rotations per minute (RPM) called for in the Topical Report (and
j associated procedures) to 45 RPM. This reduction was authorized by
1 a supeevisor employed by the contracted solidification service
j vendo Subsequently, the slower mixing speed was applied to filter
i sludge solidifications. Filter sludge work volumes were usually 120 ;
'
cubic feet or less. These changes were apparently made under dis-
cretionary steps in the procedures and were used without the review
and approval of the licensee. In November 1986, the licensee began
'
l processing filter sludge radwaste materials with higher filtrate
l Ioadings due to increased filter service times. Between November
! 1986 and April 1987, 4 shipments were made of liners containing l
1
higher filtrate-loaded sludges, (Licensee Shipment Nos. 0C-2006-86, i
'
0C-2007-86, OC-2001-87 and OC-2002-87. In December 1986, licensee
j Shipment No. 0C-2001-86 was set aside for further inspection at the (
i burial site but wasn't tapped to check for possible incomplete i
i solidification. Review of the solidification processing of the Ifner ,
! for licensee shipment No. OC 2003-87 indicated that the thermocouple t
i used to measure temperature changes associated with cement curing was j
'
lost, the volume of filter sludge materials precessed was 130 cubic
i feet and mixing speeds as low as as 30 RPM were used. The latter :
'
i changes (i.e.,lowermixingspeedandtheincreaseinwastevolume
I ;
'
.
.
.
.
8
from 120 cubic feet to 130 cubic feet) are believed to have con-
tributed to incomplete mixing of the cement (solidification agent)
with the filter sludge (waste material) and subsequent incomplete
solidification (with remaining free-standing liquid).
The inspector reviewed the corrective actions taken by the licensee.
On April 14, 1987, the licensee suspended solidification operations
and radwaste shipments pending an investigation of the problem with
shipment No. OC-2003-87. On April 15, 1987, licensee representatives
reviewed the shipment at the disposal site. The licensee requested a
review by the contract solidification service and recommendations
from the contractor for corrective action. The licensee plans to
modify all discretionary steps in solidification procedures to
include licensee review and approval of changes. Radwaste solidi-
fication and shipment will be resumed following these procedural
changes and implementation of corrective actions regarding mixer
speed and volume of waste processed in each liner. The free-standing
liquid removed from the liner will be solidified and buried by Chem
Nuclear Services, Inc.
7. Exit Interview
The inspector met with the licensee's representatives (denoted in Para-
graph 1) at the conclusion of the inspection on April 27, 1987. The
inspector summarized the scope of the inspection and findings. The
inspector discussed the violation noted by the State of South Carolina
and emphasized the need to adequately control contractor activities.
The inspector provided a copy of the letter and inspection report issued
by the South Carolina Department of Health and Environmental Control on
April 23, 1987 to the licensee on April 27, 1987 since the licensee
hadn't received his copy. No other written material was provided to the
licensee by the inspector. No information exempt from disclosure under
10 CFR 2.790 is discussed in this report.
}}