0 E. J. Mrset 1-1-85 Form Approved by Station Superintendent Effe'ctivo Dato
~
STATION PROCEDURE COVER SHEET
[]/
A.
IDENTIFICATION w
Number E0P 35 FR-H.4 Rev.
1 Title RESPONSE TO LOSS OF NORMAL STEAM RELEASE CAPABILITIES Prepared By J. D. Catlin 8.
REVIEW I have reviewed the above procedure and have found it to be satisfactory.
TITLE SIGNATURE DATE
/2!I [5 DEPARTMENT HEAD C.
UNREVIEWED SAFETY QUESTION EVALUATION DOCUMENTATION REQUIRED:
(Significant change in procedure method or scope YES [ ]
NO M as described in FSAR)
(If yes, document in PORC/SORC meeting minutes)
ENVIRONMENTAL IMPACT (Adverse environmental impact)
YES [ ]
N0 g (If yes, document in PORC/SORC meeting minutes)
D.
INTEGRATED SAFETY REVIEW REQUIRED (Affects response of Safety Systems, performance YES [ ]
NO N of safety-related control systems or performance of control systems which may indirectly affect safety system response.)
(If yes, document in PORC/SORC meeting minutes.)
E.
PROCEDURE REQUIP,EefP M SORC REVIEW YES ><1 NO [ ]
F.
(P6lIC'/50RCAPPROVAL h 0RC Meeting Number P86 c72A G.
APPROVAL AND IMPLEMENTATION The attached procedure is hereby approvt', and effective on the date below:
L v4 W
l.) ~ l
-(
Station /S@Ee/ Unit Superindndent Effect ve Date SF 301 Rev. 7 8810260545OyO[ht:3 Page 1 of 1 PDR ADOCK PDR P
E0P 35 FR-H.4 Page 1 Rev. 1 RESPONSE TO LOSS OF NORMAL STEAM RELEASE CAPABILITIES Pale No.
Eff. Rev.
1-3 1
O
- O
RESPONSE TO LOSS OF NORMAL ST2AM E0P 35 FR-H.4 Page 2 RELEASE CAPABILITIES Rev. 1 O
\\_ /
A.
PURPOSE This procedure provides actions to respond to a failure of the steam generator atmospheric dump valves and condenser dump valves.
B'.
ENTRY CONDITIONS This procedure was written for Modes 1, 2, 3 and 4.
Using this procedure when not in these modes requires a step by step evaluation to determine if the required action is still applicable to current plant conditions.
This procedure is entered from E0P 35 F-0.3, KEAT SINK Critical Safety Function Status Tree on a YELLOW conditiot.
1 e
O i
)
l 4
4 l
O l
e f
RESPONSE TO LOSS OF NORMAL STEAM E0P 35 FR-H.4 Pags 3 RELEASE CAPABILITIES Rev. 1 V
STEP ACTION /EX*ECTED RESPONSE RESPONSE NOT OSTAINED NOTE Throughout this procedure, "affected" refers to any SG in which pressure is greater than 1185 psig.
CAUTION If affected SG(s) narrow range level increases to greater than 92% (77%
for adverse centainment), steam should not be released from the affected SG(s).
1 Try To Restore Normal Steam Release capability Of Affected SG(s) a.
Atmospheric dumps QR
[}
b.
Condenser steam dump 2
Check SG Pressures - LESS THAN Manually or locally dump steam 1185 PSIG from SG(s) with pressure greater than 1185 psig.
3 Return to Procedure And Step In Effect
-FINAL-4 O
OPM341 344 d