ML20204J965
| ML20204J965 | |
| Person / Time | |
|---|---|
| Site: | Millstone, Haddam Neck, 05000000 |
| Issue date: | 06/03/1988 |
| From: | CONNECTICUT YANKEE ATOMIC POWER CO. |
| To: | |
| Shared Package | |
| ML20204H467 | List:
|
| References | |
| FR-H.2, NUDOCS 8810250303 | |
| Download: ML20204J965 (3) | |
Text
JW1 3 1988 NUMBER TTIM REV. ISSUE /DAE FR.H.2 RESPONSE TO STEAM GENERATOR Rev. 1 OVERPRESSURE A.
PURPOSE This procedure arovides actions for an overpressure condition affecting any steam generator where pressure sat increased above the highest steamline safety valve setpoint.
B.
SYMPTOMS OR ENTRY CONDITIONS Dis procedure is entered from F 0.3, HEAT SINK Critical Safety Function Status Tree on a YELLOW condition.
t Page 1 of 3
$$ko2ggggggj 3
P
JUN 3 1988 NUMBER TTTLE REV. ISSUE /DAR FR.H.2 RESPONSE TO STEAM GENERATOR Rev.1 OVERPRESSURE
(
SEP ACTION / EXPECTED RESPONSE RESPONSE NOT OBTAINED NOTE:
THROUGHOUT THIS PROCEDURE, "AFFECTED" REFERS TO ANY SG IN WHICH PRESSURE IS GREATER THAN 1034 PSIG.
1 IDENTIFY AFFECTED SG(s):
- a. Check SG pressures
- a. RETURNIQ procedure and step in ANY GREATER T AN 1034 PSIG effect.
2 VERIFY FEEDWATTIR ISOLATED TO AFFECTED SG(s):
- a. Check main feedwater flow contml
- a. Manually close feedwater fksv valves - CLOSED contml valves.
'- Check feedline bypass AOVs -
- b. Manually close feedline bypass AOVs.
CLOSED
- c. Check feedline isolation MOVs -
- c. Manually close feedline isolation CLOSED MOVs.
3 CHECK AFFECTED SG(s) WIDE O_QIQ FR H.3, RANGE LEVEL LESS THAN 72 %
RESPONSE TO SHAM GENERATOR (68 % FOR ADVERSE HIGH LEVEL, STEP 1.
CONTAINMENT) r CAUTION:
IF AFFECTED SG(s) W'OE RANGE LEVEL INCREASES TO GREATER THAN 72 % (68 % FOX DVERSE CONTAINMENT), STEAM SHOULD NOT DE RELEASED FROM THE AFFECTED SG(s).
L J
l 4
TRY TO DUMP SEAM FROM QQIQ STEP 6.
AFFECTED SG(s):
o Use atmospheric vent valve 2
o Use steam supply to tarbine driven AFW pumps M
o Use main steamline isolation valve bypass valves Page 2 of 3
3 JUN 3 1983 NUMBER TTIll REV. ISSUE /DATE FR H.2 RESPONSE TO STEAM GENERATOR Rev.1 OVERPRESSURE STEP ACTION / EXPECTED RESPONSE RESPONSE NOT OBTAlhTD 5
CHECK AFFECTED SG(s) PRESSURE:
- a. Check pressure (s)- DECREASING
- a. QQIQ Step 6.
- b. Check pressure (s)-
- b. RETURN IQ Step 3.
LESS THAN 1034 PSIG
- d. RETURNIQ procedure and step in effect r
7 CAUTIONt AFW FLOW SHOULD REhfAINISOLATED TO AFFECTED SG(s)
UNTIL A STEAbi RELEASE PATH IS ESTABUSHED.
L J
6 CHECK AFW FLOW ISOLARID TO AFFECTED SG(s) 7 CHECK RCS HOT LEG COOLDOWN RCS TO LESS TEhiPERARJRES -
1EAN 535' F(530' F FOR ADVERSE LESS TIIAN 535 F CONTAINMENT) BY DUhtPING (530' F FOR ADVERSE STEAM FROh! EiE UNAFFECED CONTAINMENT)
SG(s).
8 CONTINUE ATTEMPTS TO MANUAL 1Y DE LOCALLY DUMP STEAM FROM AFFECTED SG(s):
I o Use atmospheric vent valve 2
o Use steam supply to turbine driven AFW pumps 2
o Use main steamline isolation valve bypass valves and flog Jet steam supply valves 9
RETTJRNIQ procedure and step ineffect END Page 3 of 3