MONTHYEARML20212D4381999-09-20020 September 1999 Forwards Amend 31 to License R-103 & Safety Evaluation.Amend Authorizes Conduct of Moveable & Unsecured Experiments in Center Test Hole of Reactor ML20212D4961999-09-13013 September 1999 Informs That a Schoone Has Terminated Employment with Univ of Missouri Research Reactor as of 990820.JC Mckibben Assumed Position of Interim Reactor Manager Effective 990820 ML20210Q7301999-08-12012 August 1999 Ack Receipt of Informing NRC of Steps Taken to Correct Violations Noted in Insp of License R-103 Issued on 990701 ML20210J3681999-07-30030 July 1999 Responds to NRC Re Violations Noted in Insp Rept 50-186/99-201.Corrective Actions:Reactor Manager Reiterated That After Sample Handling & Prior to Reactor start-up That Upscale Switch Should Be in Normal Position ML20216D4181999-07-23023 July 1999 Forwards Response to NRC 990521 RAI for Evaluation of License Amend Request ML20196K4171999-07-0101 July 1999 Forwards Insp Rept 50-186/99-201 on 990607-11 at Univ of Missouri - Columbia Research Reactor & Notice of Violation ML20207A9651999-05-21021 May 1999 Forwards Request for Addl Info Re Amend Request for Amended Facility License R-103 for Univ of Missouri - Columbia Research Reactor,Submitted on 990504 ML20206A2481999-04-21021 April 1999 Informs That Umrr Is Withdrawing Request Listed as Item 2 of Re Changes to QA Program.Revised Page 4 of QA Plan Which Conforms to 10CFR71 Guidelines,Encl ML20204H8101999-02-16016 February 1999 Submits Notification Re Radioactive Spent Fuel Shipment from Univ of Missouri Research Reactor ML20203C9231999-02-0404 February 1999 Informs That Attached Ltr Request for QA Plan Amend Was Lost in Transit to Destination,Explaining Discrepancy in Date at Top of Ltr & in Area Notarized ML20203C8931999-02-0303 February 1999 Forwards DOE Ltr Dtd 990120,notifying Licensee That Federal Funds for Conversion of Reactor Not Available During FY99 ML20203C9351999-01-26026 January 1999 Requests Changes to QA Program,Updating MURR Organization Charts & QA Personnel Responsibilities Description on Pages 3,4,7,app A-1 & B-1 ML20198L1051998-12-21021 December 1998 Forwards Insp Rept 50-186/98-202 on 981116-20.No Violations Noted.Determined That Rp,Transportation,Security & Matl Control Activities at Univ of Missouri at Columbia Research Reactor Were Safety Oriented & Professional ML20198C2241998-12-15015 December 1998 Responds to 980701 Request for Approval of Route for Transporting Sf from Univ of Missouri Research Reactor to Savannah River Site,Aiken,Sc.Route Which Meets Regulatory Requirements of 10CFR73.37 & Approval Through Dec 2000 Encl ML20198A3831998-12-10010 December 1998 Discusses Concerns with Umrr Re Degradation of Beam Port Floor Surface Area & Loose Particles or Dust from Concrete Shielding That May Become Lodged in Equipment.Determined That Safety Significance of Concerns to Be Neglible ML20198C3061998-11-11011 November 1998 Forwards Info Re Radioactive Spent Fuel Shipments from Univ of Missouri Research Reactor.Info Has Been Classified as Safeguards Info,Per 10CFR73.21(b)2,not Encl ML20151T7541998-09-0303 September 1998 Informs That Wa Meyer,License SOP-2862-7,has Been Reassigned to Position That No Longer Requires SRO License ML20237C2471998-08-13013 August 1998 Submits Proposed Alternative to Literal Interpretation of Listed Step Re Implementation of Improved Controls Governing Process by Which Irradiated Topaz Is Exported,Per 10CFR110. Alternative Is Rev to 951117 Response to CAL RIII-95-04 ML20236Q8881998-07-0101 July 1998 Discusses NRC 970109 Final Approval of Encl Highway Route for Shipment of Spent Reactor Fuel Through 981231,per 10CFR73.37(b)(7).Requests Approval of Addl 2 Yrs Starting 990109.W/o Encl ML20249C1751998-06-23023 June 1998 Ack Receipt of ,Transmitting Changes to Emergency Plan for Univ of Missouri Research Reactor Submitted Under Provisions of 10CFR50.54(q) ML20248D3601998-05-27027 May 1998 Ack Receipt of Ltr Dtd 970506,which Transmitted Changes to Physical Security Plan for University of Missouri Research Reactor,Submitted Under 10CFR50.54(p) ML20249B7401998-04-16016 April 1998 Submits Advance Notification of Shipment of RQ Radioactive Matl,Fissile,Nos 7,UN2918,25,000 Lbs,Rq (Reportable quantity);1.5 Kg of Fission Products & MFP (Mixed Fission Products) to Aiken,Sc ML20216G9391998-04-15015 April 1998 Forwards Certificate to Newly Licensed Individual Pj Muren at Univ of Missouri Research Reactor ML20216C9791998-03-11011 March 1998 Ack Receipt of Informing NRC of Steps Taken to Correct Violations Noted in NOV .NRC Reviewed C/As,Which Appear to Be Adequate & Have No Further Questions at Present Time.C/As Will Be Examined During Future Insp ML20216C0541998-03-0303 March 1998 Forwards Ltr from DOE Stating That Federal Funds for Conversion of Licensee Reactor Will Not Be Available During FY98.Licensee Will Respond Again,Prior to 990327,per 10CFR50.64(c)(2) ML20203J8681998-02-27027 February 1998 Provides follow-up to Info in Re Unanticipated Reactivity Insertion ML20203H3891998-02-26026 February 1998 Forwards Amend 30 to License R-103.Amend Clarifies TS Requirements for Procedures for Preparation for Shipment of Byproduct Matl Produced Under Reactor License.Safety Evaluation Also Encl ML20203J6771998-02-25025 February 1998 Responds to NRC Re Violations Noted in Insp Rept 50-186/98-201 on 980115.Corrective Actions:All Licensed Personnel Have Completed 1997 Operating Test Sections ML20202J3141998-02-17017 February 1998 Forwards Ballots for ANS-10.4, Guidance for Verification & Validation of Scientific & Engineering Computer Programs for Nuclear Industry. Voted Approved W/Comments ML20203A2701998-02-0505 February 1998 Ack Receipt of in Response to Transmitting Nov.Corrective Actions Will Be Examined During Future Insp ML20199J7811998-02-0202 February 1998 Forwards Insp Rept 50-186/98-201 on 980112-15 & Notice of Violation.Purpose of Insp to Determine Whether Activities Authorized by License Were Conducted Safely & in Accordance W/Nrc Requirements ML20199L2161998-01-27027 January 1998 Requests Reinstatement of Senior Operator License for Pj Muren.Physical Exam for Muren Scheduled for 980130. Written Exam W/Scope as Biennial Exam Administered in Oct/ Nov 1997 Will Also Be Administered ML20199B6321998-01-23023 January 1998 Responds to NRC Re Violations Noted in Insp Rept 50-186/97-201.Corrective Actions:Calibr Source Stored in Unposted Area ML20198N5131998-01-12012 January 1998 Forwards Curriculum Vitae of EA Deutsch,Appointed Director of Univ of Missouri-Columbia Research Reactor on 971201.Encl Shows Strong Background in Business Mgt & Academic Research ML20198K5871998-01-0909 January 1998 Documents 980105 Telcon W/A Adams Re Request for Two Week Extension to Reporting Requirement for NOV Until 980125. Informed on 980107,by a Adams,That NRC Had Granted Extension ML20198N1561998-01-0909 January 1998 Forwards Corrected Pages for Page 1 of NOV & Page 1 of Insp Rept 50-186/97-201.Insp Rept Forwarded on 971211 ML20203E9251997-12-11011 December 1997 Forwards Safety Insp Rept 50-186/97-201 on 971103-07 & Notice of Violation.One Concern Noted Was Inconsistent Mgt Expectation & Practice W/Regard to Second Verification of Critical Procedure Steps in Radioisotope Svcs Program ML20211H4421997-09-29029 September 1997 Responds to Re Request for Approval to Use DOE Transcom satellite-based Vehicle Tracking Sys to Monitor Upcoming Sf Shipment from Facility to DOE Savannah River Plant ML20211A0481997-08-29029 August 1997 Requests That NRC Grant Permission to Let Shipments from Licensee Site Be Monitored by Transcom,Due to Listed Features.Safeguards Info Put on Transcom Will Not Be Compromised ML20217P3201997-08-22022 August 1997 Informs That Responsibility for Non-Power Reactor Insp Program Has Been Transferred from Nrr.All Related Repts, Correspondence & Inquires W/Docket Number Specified Should Be Directed to Listed Address ML20211A0291997-08-13013 August 1997 Submits Info Re Radioactive Spent Fuel Shipments from Univ of Missouri Research Reactor to Savannah River Site.Info Classified as Safeguards Info as Per 10CFR73.21(b)2 ML20140G8611997-05-0606 May 1997 Forwards Revised Pp to Physical Security Plan for Univ of Missouri Research Reactor.Encl Withheld Per 10CFR73.21(b)(1) & 10CFR73.21(c) ML20148C0541997-04-23023 April 1997 Forwards Info Re Radioactive Spent Fuel Shipment,Which Has Been Classified as Safeguards Info,Per 10CFR73.21(b)2. W/O Encl ML20137Q6731997-04-0404 April 1997 Expresses Appreciation for Providing Jan & March Spent Fuel Shipments ML20137D6621997-03-18018 March 1997 Forwards Copy of DOE ,To Univ of Mo Research Reactor,Notifying Licensee That Federal Funds for Conversion Unavailable During FY97 ML20136E8821997-03-0707 March 1997 Informs That No Further Enforcement Action Appropriate Based on Results of 961031 OI Investigation & Review of Corrective Actions ML20136D7081997-03-0606 March 1997 Forwards Amend 29 to License R-103 & Safety Evaluation.Amend Changes Aspects of Administrative Structure Having Oversight Authority for MURR & Corrects Inconsistency in TS Re Meeting Requirements of Reactor Advisory Committee ML20134Q1221997-02-24024 February 1997 Forwards Reactor Operator/Senior Operator License Certificates.W/O Encls ML20134P0661997-02-19019 February 1997 Discusses Revised Reactor Operator Requalification Plan for Univ of Missouri Reactor Submitted by 970107 & 0207 Ltrs. Proposed Changes Meet Requirements of 10CFR55 & Acceptable ML20134H5181997-02-0707 February 1997 Forwards Results of 970127-28 Operator Initial Exam Conducted at Facility.W/O Encl 1999-09-20
[Table view] Category:OUTGOING CORRESPONDENCE
MONTHYEARML20212D4381999-09-20020 September 1999 Forwards Amend 31 to License R-103 & Safety Evaluation.Amend Authorizes Conduct of Moveable & Unsecured Experiments in Center Test Hole of Reactor ML20210Q7301999-08-12012 August 1999 Ack Receipt of Informing NRC of Steps Taken to Correct Violations Noted in Insp of License R-103 Issued on 990701 ML20196K4171999-07-0101 July 1999 Forwards Insp Rept 50-186/99-201 on 990607-11 at Univ of Missouri - Columbia Research Reactor & Notice of Violation ML20207A9651999-05-21021 May 1999 Forwards Request for Addl Info Re Amend Request for Amended Facility License R-103 for Univ of Missouri - Columbia Research Reactor,Submitted on 990504 ML20198L1051998-12-21021 December 1998 Forwards Insp Rept 50-186/98-202 on 981116-20.No Violations Noted.Determined That Rp,Transportation,Security & Matl Control Activities at Univ of Missouri at Columbia Research Reactor Were Safety Oriented & Professional ML20198C2241998-12-15015 December 1998 Responds to 980701 Request for Approval of Route for Transporting Sf from Univ of Missouri Research Reactor to Savannah River Site,Aiken,Sc.Route Which Meets Regulatory Requirements of 10CFR73.37 & Approval Through Dec 2000 Encl ML20198A3831998-12-10010 December 1998 Discusses Concerns with Umrr Re Degradation of Beam Port Floor Surface Area & Loose Particles or Dust from Concrete Shielding That May Become Lodged in Equipment.Determined That Safety Significance of Concerns to Be Neglible ML20249C1751998-06-23023 June 1998 Ack Receipt of ,Transmitting Changes to Emergency Plan for Univ of Missouri Research Reactor Submitted Under Provisions of 10CFR50.54(q) ML20248D3601998-05-27027 May 1998 Ack Receipt of Ltr Dtd 970506,which Transmitted Changes to Physical Security Plan for University of Missouri Research Reactor,Submitted Under 10CFR50.54(p) ML20216G9391998-04-15015 April 1998 Forwards Certificate to Newly Licensed Individual Pj Muren at Univ of Missouri Research Reactor ML20216C9791998-03-11011 March 1998 Ack Receipt of Informing NRC of Steps Taken to Correct Violations Noted in NOV .NRC Reviewed C/As,Which Appear to Be Adequate & Have No Further Questions at Present Time.C/As Will Be Examined During Future Insp ML20203H3891998-02-26026 February 1998 Forwards Amend 30 to License R-103.Amend Clarifies TS Requirements for Procedures for Preparation for Shipment of Byproduct Matl Produced Under Reactor License.Safety Evaluation Also Encl ML20202J3141998-02-17017 February 1998 Forwards Ballots for ANS-10.4, Guidance for Verification & Validation of Scientific & Engineering Computer Programs for Nuclear Industry. Voted Approved W/Comments ML20203A2701998-02-0505 February 1998 Ack Receipt of in Response to Transmitting Nov.Corrective Actions Will Be Examined During Future Insp ML20199J7811998-02-0202 February 1998 Forwards Insp Rept 50-186/98-201 on 980112-15 & Notice of Violation.Purpose of Insp to Determine Whether Activities Authorized by License Were Conducted Safely & in Accordance W/Nrc Requirements ML20198N1561998-01-0909 January 1998 Forwards Corrected Pages for Page 1 of NOV & Page 1 of Insp Rept 50-186/97-201.Insp Rept Forwarded on 971211 ML20203E9251997-12-11011 December 1997 Forwards Safety Insp Rept 50-186/97-201 on 971103-07 & Notice of Violation.One Concern Noted Was Inconsistent Mgt Expectation & Practice W/Regard to Second Verification of Critical Procedure Steps in Radioisotope Svcs Program ML20211H4421997-09-29029 September 1997 Responds to Re Request for Approval to Use DOE Transcom satellite-based Vehicle Tracking Sys to Monitor Upcoming Sf Shipment from Facility to DOE Savannah River Plant ML20217P3201997-08-22022 August 1997 Informs That Responsibility for Non-Power Reactor Insp Program Has Been Transferred from Nrr.All Related Repts, Correspondence & Inquires W/Docket Number Specified Should Be Directed to Listed Address ML20136E8821997-03-0707 March 1997 Informs That No Further Enforcement Action Appropriate Based on Results of 961031 OI Investigation & Review of Corrective Actions ML20136D7081997-03-0606 March 1997 Forwards Amend 29 to License R-103 & Safety Evaluation.Amend Changes Aspects of Administrative Structure Having Oversight Authority for MURR & Corrects Inconsistency in TS Re Meeting Requirements of Reactor Advisory Committee ML20134Q1221997-02-24024 February 1997 Forwards Reactor Operator/Senior Operator License Certificates.W/O Encls ML20134P0661997-02-19019 February 1997 Discusses Revised Reactor Operator Requalification Plan for Univ of Missouri Reactor Submitted by 970107 & 0207 Ltrs. Proposed Changes Meet Requirements of 10CFR55 & Acceptable ML20134H5181997-02-0707 February 1997 Forwards Results of 970127-28 Operator Initial Exam Conducted at Facility.W/O Encl ML20133G0181997-01-0909 January 1997 Discusses 961101 Request for Approval of Route for Transporting Sf from Univ to Plant in Aiken,Sc.Route in Encl 1 Meets Regulatory Requirements of 10CFR73.37 & Encl 2 Constitutes Approval for Route Until 981231 ML20132A7811996-12-12012 December 1996 Requests Addl Info Re Amend Request for Amended Facility License R-103 for Univ of Mo Research Reactor Submitted on 961029 ML20135F5471996-12-0606 December 1996 Forwards Insp Repts 30-32695/96-02 & 50-186/96-01 on 961104- 08 ML20149H0571994-11-0404 November 1994 Forwards Amend 27 to Amended Facility License R-103 & Safety Evaluation.Amend Allows Installation of Single Pool Cooling Sys Heat Exchanger in Place of Two Existing Exchangers IR 05000183/19930041993-11-24024 November 1993 Forwards Insp Rept 50-183/93-04 on 931101-05.No Violations Noted ML20057A0111993-08-27027 August 1993 Forwards Administration of Requalification Exams,Nrc Rules & Guidance for Exams & Security Agreements for Written Exams to Be Administered at Facility on 931025 ML20056H3801993-08-25025 August 1993 Forwards OL Certificate for RA Hartweg.W/O Encl ML20056F8811993-08-12012 August 1993 Forwards Initial Exam Rept 50-186/OL-93-01 Administered During Wk of 930726.W/o Encl ML20056F4141993-08-12012 August 1993 Forwards Results of Operator Initial Exam Conducted on 930726-27.W/o Encl ML20056F8821993-08-12012 August 1993 Forwards Initial Exam Rept 50-186/OL-93-01 Administered During Wk of 930726 ML20128P8261993-02-19019 February 1993 Responds to 930209 Request for Approval of Route for Transporting Irradiated Reactor Fuel from Facility to Aiken,Sc ML20128F9891993-02-0808 February 1993 Informs That Licensee 910918 Changes to Emergency Plan for Facility Maintains Compliance w/10CFR50,app E & Acceptable IR 05000186/19920021992-12-0202 December 1992 Discusses Insp Rept 50-186/92-02 on 920903-04 & Forwards Notice of Violation,Proposed Imposition of Civil Penalty & Demand for Info.Review of Circumstances Surrounding Inadvertent Switching of Two Aliquots Discussed ML20125D9271992-11-25025 November 1992 Forwards Insp Rept 50-186/92-04 on 921102-05.No Violations Noted ML20141M5681992-08-17017 August 1992 Forwards Amend 22 to License R-103 & Safety Evaluation. Amend Rescinds Temporary Possession Limit Increases in Special Nuclear Material Granted by Amends 19 & 21 ML20059N6191990-10-10010 October 1990 Forwards Safety Insp 50-186/90-01 on 900815-1001 & Notice of Violation ML20058K9591990-08-0101 August 1990 Forwards Amend 20 to License R-103 & Safety Evaluation. Amend Allows Use of Extended Life Aluminide Fuel ML20055J1861990-07-26026 July 1990 Advises of Approval of Route to Transport Spent Reactor Fuel from Columbia,Mo to Idaho Falls,Id,Per . Arrangements W/Law Enforcement Agencies Along Route as Required by 10CFR73.37(a)(2) Completed by NRC ML20246E0841989-06-28028 June 1989 Advises That 890614 Changes to Physical Security Plan Consistent W/Provisions of 10CFR50.54(p) & Acceptable ML20248A2371989-06-0202 June 1989 Confirms 890620 Mgt Meeting W/Licensee in Columbia,Mo to Discuss Results of NRC Insp & Licensee Response ML20246M1161989-05-0808 May 1989 Forwards Amend 18 to License R-103 & Safety Evaluation.Amend Shifts Administrative Authority to Univ of Missouri at Columbia ML20246M7421989-05-0505 May 1989 Advises That Changes to Emergency Plan Consistent W/ Provisions of 10CFR50,App E & Acceptable ML20246G2881989-05-0404 May 1989 Forwards Safety Insp Rept 50-186/89-01 on 890306-10 & Notice of Violation ML20247M8271989-03-30030 March 1989 Discusses Licensee Requests for Changes to Requalification Program.Requests Include Extension of Max Time Period of 24 Months for Requalification Cycle to Account for Changes in Outage Schedules & Reorganization of Training Programs IR 05000186/19880031989-02-23023 February 1989 Ack Receipt of Informing NRC of Steps Taken to Correct Violations Noted in Insp Rept 50-186/88-03.Encl Evaluation of Severity Level Violation Designation Withheld (Ref 10CFR73.21) ML20235S2131989-02-21021 February 1989 Forwards Exam Rept 50-186/OL-89-01 Administered on 890118-19.Facility Comments & NRC Resolution of Comments, Exam & Answer Key & Simulation Facility Rept Also Encl 1999-09-20
[Table view] |
Text
q- .
Fcbru:xy 17, 1998 Mr. Tawfik M. Raby Chairman, N 17 Building 235, Room A141 Nationalinstitute of Standards and Technology Gaithersburg, Maryland 20899
Dear Mr. Raby:
SUBJECT:
N 17 COMMITTEE BAL. LOT Enclosed are my ballots for ANS 10.4, " Guidelines for the Verification and Validation of
- Scientific and Engleeering Computer Programs for the Nuclear Industry" (Rea trmation) and ANS 15,20, " Control and Safety Systems for Research Reactors." I have vot.J " approved with comments." Furthermore, I have leviewed the Scope, and have no objections, if you have any questions concerning this ballot, please contact me at 3014151127.
Sincerely, ORIGINAL SIGNED BY:
Alexander Adams, Jr., Senior Project Managar Non Power Reactors and Decommissioning Project Directorata Division of Reactor Program Management Office of Nuclear Reactor Regulation
Enclosure:
As stated i
DISTRIBUTION:
tMRD COPY. .
[Occket File 60186 -d EHylton h l
(
PUBLIC PDND r/f SWeiss AAdams PDN p PDND A PDND:(A)D A s n MMendonca 2/ /93 2//' 98 2/l 98 OFFICIAL RECORD COPY ;.
DOCUMENT NAME: G:\SECY\ ADAMS \ BALLOT
.. .40 5,1llR11,1lllll g.30
^
Neb b b
,*t223o130980217.oou
- o mogg6
Q
, p* ** o g ug% UNITED STATES i y NUCLEAR REGULATORY COMMISSION
- N}j WAsHINeToN, D.c. souH001
Mr. Tawfik M. Raby Chairman, N 17 Building 235, Room A141 NationalInstitute of Standards and Technology Gaithersburg, Maryland 20899
Dear Mr. Raby:
SUBJECT:
N 17 COMMITTEE BALLOT Enclosed are my ballots for ANS 10.4, " Guidelines for the Verification and Validation of Scientific and Engineering Corr.puter Programs for the Nuclear Industry" (Reaffirmation) and ANS 15.20, " Control and Safety Systems for Research Reactors." I have voted " approved with comments." Furthermore, I have reviewed the Scope, and have no objections.
If ycu have any questions concerning this ballot, please contact me at 3014151127.
Sincerely, M41 Alexander Adams, Jr., Seni r ect Manager Non Power Reactors and Decommissioning Project Directorate Division of Reactor Program Management Office of Nuclear Reactor Regulation
Enclosure:
As stated
=irmvi 9- e p. e, r+ -u.. - -
y
i I
ANSI N 17 COMMITTEE BALLOT DOCUMENY: ANS 10.4
- Guidelines for the Verification and Validation of Scientific and Engineering Computer Programs for the Nuclear IndustY (Reaffirmation),
r BALLOT DUE: February 17.1998 Approved X Approved with Comments Not Approved Not Voting Comments: (NOTE all ' Approved with Comments' and *Not Approved
- ballots must include comments.
See attached.
Alexander Adamn J.r.
Print Name Retum ballot to: -
Signature Tawfik M. Raby USNRC Chairman, N 17 Representing NationalInstitute of Standards & Technology Building 235, Room A141 , si,ino Galthersburg, MD 20899 ' ' ' ' ' Date
O 6
l NUCLEAR REGULATORY COMMENTS ON l ANS 10.4 GUIDELINES F0F.THE VERIFICATION AND VALIDATION OF SCIENTIFIC AND ENGINEERING COMPUTER PROGRAMS FOR THE NUCLEAR INDUSTRY l
i l The standard is acceptable as written. However, because the standard dates from 1987 l the standard does not incorporate the many lessons learned by the computer industry in l the last decade. The working group for this standard should consider updating the l standard as soon as possible to apply the state of the practice to verification and validation-of software reflected in IEEE standards. Most of these standards were written for commercial use and contain the flexibility to be modified for software projects of varying safety significance.
l
_ J
. I ANSI N 17 COMMITTEE BALLOT DOCUMENT; ANS 15.20
- Control and Safety Systems f ar Research Reactors *.
BALLOT DUE: February 17.1998 X Approve'l with Comments Not Approved Not Voting Comments: (NOTE all' Approved with Comments
- and 'Not App Dved" ballots must include comments.
See attached.
Alavandpe AAmme .tr, Print Name Retum ballot to: '
. g g' Signature Tawfik M. Raby USNRC Chairman, N 17 Represon'*"
. NationalInstitute of Standards & Technology Building 235, Room A141 ? /17 /M Gahhersburg,MD 20099 Date a -, , ,,.---r
. , . - ~ , e- - - , - - - - .
.--c-u,.--- - , . , . , ,-,-- -..,.-,,..,,,-r, -
,-w. -,---
i.
NUCLEAR REGULATORY COMMENTS ON ANS 15.20 CONTROL AND SAFETY SYSTEMS FOR RESEARCH REACTORS The standard is acceptable as written. However, thia standard has been under development since 1987 when a working group was put into place to specifically incorporate the use of computer technology into this standard. We believe this version of .
the standard does not incorporate'the many lessons learned by the computer industry in the last decade and should be updated at the first revision. For example, the unty software document referenced is NUREG/CR 4640, " Handbook of Sof tware Quality Assurance
. Techniques Appilcable to the Nuclear industry" (August,1987) which in to n references other documents from the early 80's. We recommend that this standard ieference current IEEE standards in this area. Most of these standards were written for commercial use and contain the flexibility to be modified for software projects of varying safety significance.
.- - _ _ _ , _ - _ . .- , -- . - - - . - _ - _ - - _--