ML20207A965

From kanterella
Jump to navigation Jump to search
Forwards Request for Addl Info Re Amend Request for Amended Facility License R-103 for Univ of Missouri - Columbia Research Reactor,Submitted on 990504
ML20207A965
Person / Time
Site: University of Missouri-Columbia
Issue date: 05/21/1999
From: Alexander Adams
NRC (Affiliation Not Assigned)
To: Deutsch E
MISSOURI, UNIV. OF, COLUMBIA, MO
References
NUDOCS 9905280067
Download: ML20207A965 (4)


Text

%

May 21, 1999 l

l l

Dr. Edward A. Deutsch, Director l

Research Reactor Center l

University of Missouri-Columbia Research Park i

Columbia, Missouri 65211

SUBJECT:

REQUEST FOR ADDITIONAL INFORMATION -(TAC NO. MA5384)

Dear Dr. Deutsch:

i We are continuing our review of your amendment request for Amended Facility License No. R-103 for the University of Missouri-Columbia Research Reactor which you submitted on May 4,1999. During our review of your amendment request, questions have arisen for which we require additionalinformation and clarification. Please provide responses to the enclosed request for additionalinformation within 45 days of the date of this letter. In accordance with 10 CFR 50.30(b), your response must be executed in a signed original under oath or affirmation. Following receipt of the additionalinformation, we will continue our evaluation of your amendment request.

If you have any questions regarding this review, please contact me at (301) 415-1127.

Sincerely, ORIGINAL SIGNED BY:

l Alexander Adams, Jr., Senior Project Manager Events Assessment, Generic Communications and Non-Power Reactors Branch Division of Regulatory Improvement Programs Office of Nuclear Reactor Regulation Docket No. 50-186 l

s a ed l

cc w/ enclosure:

See next page DISTalBUTION:

E-MAIL HARD COPY PDoyle Pisaac j Docket File' 50-186 T#

LMarsh

~

TDragoun MMendonca PUBLIC AAdams

/

l TMichaels WEresian OGC (015-B18)

EHylton p ",

SHolmes CBassett -

DMatthews REXB r/f l

GHill (2) (T5-C3)

TBurdick REX M

RE REXB:BC AA on LMarsh 5f7#f99

-?a40 5fg fag 5fu,93 OFFICIAL RECORD COPY DOCUMENT NAME: G:\\REXB\\AXA\\RAIM5384 9905280067 990521 PDR ADOCK 05000186 P

PDR l

-w

%}

l ps cc:oq l

g t

UNITED STATES j

NUCLEAR REGULATORY COMMISSION t

WASHINGTON, D.C. 20066-4001

          • [

May 21, 1999

.', 2dward A. Deutsch, Director Research Reactor Center University of Missouri-Columbia Research Park Columbia, Missoun 65211 i

SUBJECT:

REQUEST FOR ADDITIONAL INFORMATION (TAC NO. MA5384)

Dear Dr. Deutsch:

We are continuing our review of your amendment request for Amended Facility License No. R-103 for the University of Missouri-Columbia Research Reactor which you submitted on May 4,1999. During our review of your amendment request, questions i

have arisen for which we require additionalinformation and clarification. Please provide responses to the enclosed request for additional information within 45 days of the date of this letter. In accordance with 10 CFR 50.30(b), your response must be executed in a signed original under oath or affirmation. Following receipt of the additionalinformation, we will continue our evaluation of your amendment request.

If you have any questions regarding this review, please contact me at (301) 415-1127.

Sincerely, l

&M Alexander Adams, Jr., Senior roject Manager Events Assessment, Generic Communications and Non-Power Reactors Branch Division of Regulatory improvement Programs Office of Nuclear Reactor Regulation l

Docket No. 50-186

Enclosure:

As stated cc w/ enclosure:

See next page L

q e\\

4 l

l l

University of Missouri Docket No. 50-186 at Columbia f

cc:

University of Missouri Associate Director Research Reactor Facility Columbia, MO 65201 1

A-95 Coordinator l

Division of Planning -

l Office of Administration P. O. Box 809, State Capitol Bldg.

Jefferson City, MO 65101 l

l 1

l l

r b

l l

i t

l 4

I

Q

~

I1 ENCLOSURE i

REQUEST FOR ADDITIONAL INFORMATION UNIVERSITY OF MISSOURI-COLUMBIA RESEARCH REACTOR DOCKET NO. 50-186 I

1.

Please describe the methods used to estimate and/or measure the reactivity worth of samples irradiated in the center test hole and the accuracy of the methods used.

2.

Please describe your experience with estimating the reactivity of samples placed in the center test hole. Over the past 10 years have there been any samples where the pre-irradiation reactivity estimate and/or measurement was in error to the extent where it would have caused a violation of reactivity limits considering the requested changes to the license?

3.

In TS 3.6 g. you changed the first word of the TS from " Experiments" to j

"Experirnent." If this is not a typographic error please explain why you are making this change.

j l