i APPENDIX A NOTICE OF VIOLATION Louisiana Power and Light Company Docket No.:

50-382 Waterford 3 Steam Electric Station License No.: NPF-38 During an NRC inspection conducted on August 5-9, 1985, a violation of NRC requirements was identified.

The violation involved inadequate training for personnel assigned to the emergency response organization.

In accordance with the " General Statement of Policy and Procedure for NRC Enforcement Actions,"

10 CFR Part 2, Appendix C (1985), the violation is listed below:

Inadequate Training 10 CFR 50.47(L)(15) requires that adequate provisions exist in the emergency plan to ensure that radiological emergency response training is provided to those who may be called on to assist in an emergency.

Section 8.1.1.3 of the Emergency Plan states, " personnel assigned to the W3SES emergency organization with specific Emergency Plan duties and responsibilities receive specialized training for their respective assignments.

The Emergency Plan Training Program ensures that station personnel, who will be active participants in the emergency organization, are familiar with the contents of the Emergency Plan and Emergency Plan Implementing Procedure (EPIP's)."

Contrary to the above, certain station personnel assigned to the emergency organization had not received appropriate general and specific emergency plan and procedure training, as evidenced by the following:

On July 6-8, 1985, NRC inspectors conducted walkthroughs simulating accident conditions with two shift supervisors and control room supervisors.

The selected personnel were unable to properly use the EPIP's to fr ^mulate protective action recommendations to offsite agencies.

This is a Severity Level IV violation (Supplement VIII) (382/8523-01).

Pursuant to the provisions of 10 CFR 2.201, Louisiana Power and Light Company is hereby required to submit to this office within 30 days of the date of the letter transmitting this Notice, a written statement or explanation in reply, including for each violation:

(1) the reason for the violations if admitted, (2) the corrective steps which have been taken and the results achieved, (3) the corrective steps which will be taken to avoid further violations, and (4) the date when full compliance will be achieved.

Where good cause is shown, consideration will be given to extending the response time.

Dated at Arlington, Texas, this B.Nfay of b w.t v., 1985.

8511260577 851114

{DR ADOCK 05000382 PDR