Monthly Operating Repts for Feb 1985
ML20115G489
Person / Time
Site: Prairie Island  Xcel Energy icon.png
Issue date: 02/28/1985
From: Dugstad D, Musolf D
NORTHERN STATES POWER CO.
To:
NRC OFFICE OF RESOURCE MANAGEMENT (ORM)
References
NUDOCS 8504220216
Download: ML20115G489 (9)


Text

_. _ _ -

He8BoIIVE_SUdde8Y_QE_QEEBoIING_EXEEBIENCE-DOCKET NO. 50-282 UNIT PRAIRIE ISLAND NO.i DATE MARCH 5, 1985 COMPLETED BY DALE DUGSTAD TELEPHONE 612-388-1121 MONTH: FEBRUARY 1985 THE UNIT WAS WAS OFF-LINE FOR THE-TEN YEAR INSPECTION AND REFUELING OUTAGE FOR THE ENTIRE MONTH. EXPECTED STARTUP IS EARLY MARCH.

G 8504220216 850228 PDR ADOCK 05000282-R PDR TJ M I k t i

c -

DeILY_UNII_E0 WEB _QUIEUI DOCKET NO. 50-282 UNIT PRAIRIE ISLAND NO.1 DATE MARCH 5, 1985 COMPLETED BY DALE DUGSTAD TELEPHONE 612-388-1121 MONTH FEBRUARY 1985 DeY eVEBeGE_LQeD__dWE:NEI 1 0 2 0 3 0 4 0 5 0 6 0 7 -3 0 -3

9. -3 10 -3 ii -3 12 -3 13 -3 14 -3 15 -3 16 -3 17 -3 18 -3 19 -2 20 -2 21 -2 22 -3 23' -3 24 -3 25 -3 26 -3 27 -3 28 -3 AVERAGE LOADS ABOVE 503 MWE-NET ARE DUE TO COOLER CONDENSER CIRCULATING WATER

DEE86IING_DGIe_ BEE 08I DOCKET NO.-50-282 UNIT PRAIRIE ISLAND NO.1 DATE MARCH 5, 1985 COMPLETED BY DALE DUGSTAD TELEPHONE 612-388-1121 QEEBeIING_SIGIUS 1.. UNIT NAME: PRAIRIE ISLAND NO. 1 ______________________

~2.-REPORTING PERIOD: FEBRUARY 1985 i NOTES: l

3. LICENSED THERMAL POWER (MWT): 1650 l l
4. NAMEPLATE' RATING (GROSS MWE). 593 l -l
5. DESIGN ELECTRICAL' RATING (NET MWE): 530 l l
6. MAXIMUM DEPENDABLE CAPACITY (GROSS MWE): 534 l l
7. MAXIMUM DEPENDABLE CAPACITY (NET MWE): 503- 1____________________1
8. IF CHANGES OCCUR IN CAPACITY RATINGS (ITEMS NUMBER 3 THROUGH 7)

SINCE LAST REPORT GIVE REASON: N/A

9. POWER LEVEL TO WHICH RESTRICTED, IF ANY (NET MWE): N/A
10. REASONS FOR RESTRICTIONS, IF ANY: N/A THIS-MONTH YR-TO-DATE . CUMULATIVE
11. HOURS IN REPORTING PERIOD 672 1416 98232
12. NUMBER OF-HOURS REACTOR WAS CRITICAL 0.0 265.0 80259.3
13. REACTOR RESERVE SHUTDOWN HOURS 0.0 0.0 5571.1
14. HOURS GENERATOR ON-LINE 0.0 264.0 78931.8
15. UNIT RESERVE SHUTDOWN HOURS 0.0 0.0 0.0 16.. GROSS THERMAL ENERGY GENERATED (MWH). 0 323324 123922582 Li?. GROSS ELECTRICAL ENERGY. GENERATED.(MWH) 0 107920 40400020
18. NET ELECTRICAL ENERGY GENERATED (MWH) 0 98163 37848981
19. UNIT SERVICE FACTOR O.0 18.6 80.4
20. UNIT AVAILABILITY FACTOR 0.0 18.6 80.4
21. UNIT CAPACITY FACTOR (USING MDC NET) 0.0 '13.8 76'.6-

~22.-UNIT CAPACITY FACTOR (USING DER NET)- 0.0 13.1 72.7

- 23. UNIT FORCED OUTAGE RATE 0.0 0.0 8.2

24. FORCED OUTAGE HOURS 0.0 0.0 7044.4-
25. SHUTDOWNS SCHEDULED OVER NEXT 6 MONTHS (TYPE, DATE & DURATION OF EACH):

1

-26. IF CURRENTLY SHUTDOWN ESTIMATED STARTUP DATE: MARCH 11, 1985 i

PINGP 120, Rsv. 7 ,

UNIT SUUTDOWHS AND F0WER REDUCTIONS DOCERT NO. 50-282 UNIT NAME Frairia tetand Iso.1 -

DATE March 5. 1985 REPORT HONTH FEBRUARY 1985 COMPLETED BY Date Dunstad TELEPHONE 632-388-182I f

l NETil0D OF SHU1 TING DOWN REM LICENSEE SYSTFM CCHFONDrf ,

DATE TYPE DURATION REASON TOR OR REDUC- EVENT CDDE CODE (5) CAUSE/ CORRECTIVE ACTION /00telENTS (2) INC POWER (3) ERPORT (4)

TY mt DD (I) (IK)URS)

S 672.0 C 4 N/A N/A N/A Ten year inspection outage and refuellos.

85 01 Il l -

. a l

(3) HETil0D (4) SYSTDI CODE (1) TYPE (2) REASON Is Manual Draf t IEEE Std F Forced At Equipment Failure (Explain) 805-1984(F805-D5) 2 , Manual Trip S: Scheduled B: Maintenance or Test 3: Automatic Trip C Refueling D Regulatory Restriction 4: Continued E Operator Training & Licensa Examination 5: Reduced Load 9: Other (5) COMPONENT CODE

- F: Administrative IEEE Std 803A-1983 G: Operational Error (Emplain)

H: Other (Fxplain) l l

i

m

. 4

  • NeBBeIIVE_SuddeBY_QE_DEEB8IING_EXEEBIENCE DOCKET NO. 50-306 UNIT PRAIRIE ISLAND NO.2

.DATE MARCH 5, 1985 COMPLETED BY DALE DUGSTAD TELEPHONE 612-388-1121 MONTH FEBRUARY 1985.

THE UNIT WAS BASE LOADED THIS MONTH, NO SHUTDOWNS.

v- 1 77

,.'.a DeILY_UNII_EDWEB_QUIEUI DOCKET NO. 50-306

-UNIT PRAIRIE ISLAND NO.2 DATE MARCH 5, 1985 COMPLETED BY DALE DUGSTAD TELEPHONE 612-380-1121 MONTH FEBRUARY 1985 DeX eVEBeGE_L0eD__dWE:NEI-1- 533 2 526 3 529 4 530' 5 532 6 523 7 526 8 532 9 526 10 535 11 532 12- - 529 13 529 14 531 15- 527 16 532 17 529

'i8 52, 19 528 20 531

'21 526,.

22 531 23 522 24 533 25 529 26 524 27 527 28 526 i

e AVERAGE LOADS ABOVE 500 MWE-NET ARE DUE TO COOLER CONDENSER CIRCULATING WATER L-

..<+

QEEBoIING_D6Ie_8EEQ8I DOCKET NO. 50-306 UNIT PRAIRIE ISLAND NO.2 DATE MARCH 5, 1985 COMPLETED BY DALE DUGSTAD TELEPHONE 612-388-1121

'0EEBeIING_SIeIUS

1. UNIT NAME: PRAIRIE ISLAND NO. 2 ______________________
2. REPORTING PERIOD: FEBRUARY 1985 l NOTES: l
3. LICENSED THERMAL POWER (MWT). 1650 l l
4. NAMEPLATE RATING (GROSS MWE): 593 l l
5. DESIGN ELECfRICAL RATING (NET MWE): 530 l l
6. MAXIMUM DEPENDABLE CAPACITY (GROSS MWE); 531 l l
7. MAXIMUM DEPENDABLE CAPACITY (NET MWE): 500 1____________________1
8. IF CHANGES OCCUR IN CAPACITY RATINGS.(ITEMS NUMBER 3 THROUGH 7)

SINCE LAST REPORT GIVE REASON: N/A

9. POWER LEVEL TO WHICH RESTRICTED, IF ANY (NET MUE): N/A
10. REASONS FOR RESTRICTIONS, IF ANY: N/A THIS MONTH YR-TO-DATE , CUMULATIVE
11. HOURS IN REPORTING PERIOD 672 1416 89350
12. NUMBER OF HOURS REACTOR WAS CRITICAL 672.0 1416.0 77510.7
13. REACTOR RESERVE SHUTDOWN HOURS 0.0 0.0 1516.1
14. HOURS GENERATOR ON-LINE 672.0 1416.0 76540.3
15. UNIT' RESERVE SHUTDOWN HOURS 0.0 0.0 0.0
16. GROSS THERMAL ENERGY GENERATED'(MWH) 1105663 2283411 120443643

- 1 '7 . GROSS. ELECTRICAL ENERGY GENERATED (MWH) 373150 771450 38674990

18. NET ELECTRICAL ENERGY GENERATED (MWH) 355349 734452 36615291
19. UNIT SERVICE FACTOR 100.0 100.0 85.7

-20. UNIT AVAILABILITY FACTOR- 100.0 100.0 85.7

21. UNIT CAPACITY FACTOR (USING MDC NET) 105.8 103.7 82.0
22. UNIT CAPACITY FACTOR (USING DER NET) 99.8 97.9 77.3
23. UNIT FORCED OUTAGE RATE O.0 0.0 4.0 24.. FORCED OUTAGE HOURS 0.0 0.0 3209.6
25. SHUTDOWNS SCHEDULED OVER NEXI 6 MONTHS (TYPE, DATE & DURATION OF EACH):

IEN_YEe8_QUIoGE_IN__eUGUSI_______1285.__

26. IF CURRENTLY SHUTDOWN ESTIMATED STARTUP DATE: N/A L

. FINbP 12U, M3V. # . ,

INf1T SHUIDOWNS AND POWER REDUCTIONS DOCEET NO. 50- 306 '.

UNET NAME Prairie taland No. 2 DATE March 5,1985 REPORT MONTM FEBRUART 1985 . COMPLETED BY Date Dunstad TELEPHONE 612-388-1828 NETIIOD OF Shin TING DOWN RE&t LICENSEE SYSTEM COMPONENT DATE TYPE DURATION REASON TOE OR REDUC- EVENT CODE CODE _ _ _ _ _ _ _ _ _

YT }ti DD (1) (Il0URS) (2) IMC POWEE (3) 888087 (4) IM CAUSE/ CORRECTIVE ACTION /ta . asa None.

1) TYPE (2) REASON (3) METHOD (4) SYSTDI CODE F Forced At Equipment Failure (Emplain) la Manual Draft IEEE Std S: Scheduled B: Maintenance or Test 2: Manual Trip 805-1984(P805-DS)

C Refueling 3: Automatic Trip '

Da Regulatory Restriction 4 Continued E: Operator Training & License Examination 5: Reduced Load F: Administrative 9: Other (5) COMPONENT CODE G: Operational Error (Explain) IEEE Std 803A-1983 H: Other (Explain)

O , . . _ .

Northem States Power Company 414 Nicollet Mall Minneapoks. Minnesota 55401 Telephone (612) 330 5500 March 6, 1985 Director, Office of Resource Management U S Nuclear Regulatory Commission Washington, DC 20555 PRAIRIE ISLAND NUCLEAR GENERATING PLANT Docket No. 50-282 License No. DPR-42 50-306 DPR-60 Monthly Operating Report February, 1985 Attached are twelve copies of the Monthly Operating Report for February, 1985 for the Prairie Island Nuclear Generating Plant.