Northern States Power Company Prairlo Island Nuclear Generating Plant 1717 Wakonade Dr. East Welch, Minnesota 55089 October 5,1999 Technical Specifications 6.7.A.3 US Nuclear Regulatory Commission Attn: Document Control Desk Washington, DC 20555 PRAIRIE ISLAND NUCLEAR GENERATING PLANT Docket Nos. 50-282 License Nos. DPR-42 50-306 DPR-60 Monthly Operating Roport September,1999 Attached is the Monthly Operating Report for September,1999 for the Prairie Island Nuclear Generating Plant.
Joel P. Sorensen Site General Manager Prairie Island Nuclear Generating Plant c:
Regional Administrator-Ill, NRC NRR Project Manager, NRC NRC Resident inspector State of Minnesota - Steve Minn Attachment ju"188Ns8j2)
TL=ay ' ;
a b
NRC MONTHLY REPORT PRINTED 10/5/199 Page 1 DOCKET NO. 50-282 UNIT PRAIRIE ISLAND NO.1 DATE 10/5/1999 COMPLETED BY DALE DUGSTAD PHONE 651388-1121-4376 NARRATIVE
SUMMARY
OF OPERATING EXPERIENCE MONTH: SEPTEMBER 1999 During the month of September, Unit 1 was base loaded.
There were no power reductions or shutdowns.
There are no other items to report.
CURRENT CONTINUOUS OPERATING RUN OF 126 DAYS i
1 NRC MONTHLY REPORT PRINTED 10/5/199 Page 2 i
j DOCKET NO. 50-282 l
UNIT PRAIRIE ISLAND NO.1 DATE 10/5/1999 COMPLETED BY DALE DUGSTAD PHONE 651-3881121-4376 OPERATING DA'TA REPORT OPfE_R, ATING STATUS
- 1. UNIT NAME:
PRAIRIE ISLAND NO.1
- 2. REPORTING PERIOD:
SEPTEMBER 1999
- 3. LICENSED THERMAL POWER (MWT): 1650
- 4. NAMEPLATE RATING (GROSS MWE): 593
- 5. DESIGN ELECTRICAL RATING (NET MWE): 536
- 6. MAXIMUM DEPENDABLE CAPACITY (GROSS MWE):
554
- 7. MAxit.8UM DEPENDABLE CAPACITY (NET MWE):
522
- 8. IF CHAN6C4 OPCUR IN CAPACITY RATINGS (ITEMS 3 - 7) SINCE LAST REPORT, GIVE REASON:
NONE
- 9. POWER LEVEL TO WHICH RESTRICTED, IF ANY (NET MWE): NONE
- 10. REASONS FOR RESTRICTIONS,IF ANY:
NONE i
THIS MONTH YR-TO-DATE CUMULATIVE
- 11. HOURS IN REPORTING PERIOD 720 6551 226079 J
- 12. NUMBER OF HOURS REACTOR CRITICAL 720.0 5492.3 194279 8
]
- 13. REACTOR RESERVE SHUTDOWN HOURS 0.0 0.0 5571.1
- 14. HOURS GENERATOR ON-LINE 720.0 5435.5 192374.2
- 15. UNIT RESERVE SHUTDOWN HOURS 0.0 0.0 0.0
- 16. GROSS THERMAL ENERGY GENERATED (MWH) -
1185402 8858349 306088704
- 17. GROSS ELECTRICAL ENERGY GENERATED (MWH) 407910 3034750 101304720
- 18. NET ELECTRICAL ENERGY GENERATED (MWH).
387442 2867399 95310881
- 19. UNIT SERVICE FACTOR 100.0 83.0 85.1
- 20. UNIT AVAILABILITY FACTOR 100.0 83.0 85.1
- 21. UNIT CAPACITY FACTOR ( MDC NET) 103.1 83.9 83.3
- 22. UNIT CAPACITY FACTOR ( DER NET) 100.4 81.7 79.5
- 23. UNIT FORCED OUTAGE RATE 0.0 2.8 4.7
- 24. FORCED OUTAGE HOURS 0.0 156.6 9483.8 1
- NRC MONTHLY REPORT PRINTED 10/5/199 Page 3 DOCKET NO. 50-282 UNIT PRAIRIE ISLAND NO.1 DATE 10/5/1999 COMPLETED BY DALE DUGSTAD PHONE 651388-1121-4376 UNIT SHUTDOWNS AND POWER REDUCTIONS MONTH: SEPTEMBER 1999 DATE UNIT TYPE HOURS REASON METHOD LER NUMBER SYSTEM COMPONENT 9/30/1999 1
N/A 0
NOTES:
None.
,1y21 REASQN METHOD SYSTEM CODE F-FORCED A-EQUIPMENT FAILURE 1-MANUAL DRAFT IEEE STD S-SCHEDULED
. B-MAINTENANCE OR TEST 2-MANUAL TRIP
~
C-REFUELING 3-AUTO TRIP D-REGULATORY RESTRICTION 4-CONTINUED E-OPERATOR TRAINING AND 5-REDUCED LOAD COMPONENT CODE LICENSE EXAMINATION I
9-OTHER IEEE STD 803A-1983 F-ADMINISTRATIVE G-OPERATIONAL ERROR H-OTHER
1 NRC MONTHLY REPORT PRINTED 10/5/199 Page 4 l
l DOCKET NO. 50-306 UNIT PRAIRIE ISLAND NO. 2 DATE 10/5/1999 COMPLETED BY DALE DUGSTAD PHONE 651-388-1121-4376 NARRATIVE
SUMMARY
OF OPERATING EXPERIENCE MONTH: SEPTEMBER 1999 During the month of September, Unit 2 was base loaded.
)
There were no shutdowns and only one power reduction for this month.
On the 26th, the Unit's power was reduced to perform a Turbine Valve Test.
There are no other items to report.
1 CURRENT CONTINUOUS OPERATING RUN OF 235 DAYS
NRC MONTHLY REPORT PRINTED 10/5/199 Page 5 DOCKET NO. 50-306 UNIT PRAIRIE ISLAND NO. 2 DATE 10/5/1999 COMPLETED BY DALE DUGSTAD PHONE 651388-1121-4376 OPERATING DATA REPORT OPERATING STATUS
- 1. UNIT NAME:
PRAIRIE ISLAND NO. 2
- 2. REPORTING PERIOD:
SEPTEMBER 1999
- 3. LICENSED THERMAL POWER (MWT): 1650
- 4. NAMEPLATE RATING (GROSS MWE):
593
- 5. DESIGN ELECTRICAL RATING (NET MWE): 536
- 6. MAXIMUM DEPENDABLE CAPACITY (GROSS MWE):
554
- 7. MAXIMUM DEPENDABLE CAPACITY (NET MWE):
522 8.1F CHANGES OCCUR IN CAPACITY RATINGS (ITEMS 3 - 7) SINCE LAST RtiPORT, GiVE REASON:
NONE
- 9. POWER LEVEL TO WHICH RESTRICTED, IF ANY (NET MWE): NONE
- 10. REASONS FOR RESTRICTIONS, IF ANY:
NONE l
THIS MONTH YR-TO-DATE CUMULATIVE
- 11. HOURS IN REPORTING PERIOD 720 6551 217197
- 12. NUMBER OF HOURS REACTOR CRITICAL 720.0 6516.8 191838.9
- 13. REACTOR RESERVE SHUTDOWN HOURS 0.0 0.0 1516.1
- 14. HOURS GENERATOR ON-LINE 720.0 6481.9 190266.1
- 15. UNIT RESERVE SHUTDOWN HOURS 0.0 0.0 0.0
- 16. GROSS THERMAL ENERGY GENERATED (MWH) 1181068 10532037 303683118
- 17. GROSS ELECTRICAL ENERGY GENERATED (MWH) 405650 3593780 99629710
- 18. NET ELECTRICAL ENERGY GENERATED (MWH) 384938 3400403 94186732
- 19. UNIT SERVICE FACTOR 100.0 98.9 87.6 l
- 20. UNIT AVAILABILITY FACTOR 100.0 98.9 87.6 l
21, UNIT CAPACITY FACTOR ( MDC NET) 102.4 99.4 86.2
- 22. UNIT CAPACITY FACTOR ( DER NET) 99.7 96.8 81.8
- 23. UNIT FORCED OUTAGE RATE 0.0 0.0 2.9
- 24. FORCED OUTAGE HOURS 0.0 0.0 5662.8 l
1 1:
l
-m
1 NRC MONTHLY REPORT PRINTED 10/5/199 Page 6 DOCKET NO. 50-306 UNIT PRAIRIE ISLAND NO. 2 l
DATE 10/5/1999 COMPLETED BY DALE DUGSTAD PHONE 651-388-11214376 1
UNIT SHUTDOWNS AND POWER REDUCTIONS l
MONTH: SEPTEMBER 199 DATE UNIT TYPE HOURS REASON METHOD LER NUMBER SYSTEM COMPONENT 9/26/1999 2
S 0
B 5
N/A N/A N/A NOTES: Turbine valve testing.
M REASON METHOD SYSTEM CODE F-FORCED -
A EQUIPMENT FAILURE 1-MANUAL DRAFT IEEE STD S-SCHEDULED B-MAINTENANCE OR TEST 2 MANUAL TRIP C-REFUELING 3-AUTO TRIP D-REGULATORY RESTRICTION 4-CONTINUED E-OPERATOR TRAINING AND 5-REDUCED LOAD COMPONENT CODE LICENSE EXAMINATION 9-OTHER IEEE STD 803A-1983 F-ADMINISTRATIVE G-OPERATIONAL ERROR H-OTHER i
l
!