._ __. _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ - _ _ _ _ _ _ _ _ _ _ _ _ _ _ - _ _ _ _ _ _ _ _ _ _ - _ _ _ _ _ _ _ _ _ - _ _ _ _ _ _ _ _ _ _
NORTHERN STATES POWER COMPANY 414 NICOLLET MALL MINNEAPOLIS, MINNESOTA S5401 NORTHERN STATES POWER COMPANY PRAIRIE ISLAND NUCLEAR GENERATING PLANT UNIT 1 1717 WAKONADE DRIVE E WELCH, MINNESOTA 55089 INSERVICE INSPECTION
SUMMARY
REPORT INTERVAL 3, PERIOD 1 AND 2 REFUELING OUTAGE DATES 10-18-1997 TO 12-12-1997 CYCLE 18, 03-03-1996 TO 12-12-1997 COMMERCIAL SERVICE DATE DECEMBER 16,1973 i
/
Prepared By: revvpCMW/ /^-
Inspection Supervisor n
Reviewed By: n[O ISI Program Enginber I V% }
Approved By: d A lOk hb Supenntendent of Matenals and Special Processes Report Date: #44"/ /
l
^
9803200131 980316 PDR ADOCK 05000282 i G PDR l
l ERRATA SHEET The end of the outage was December 14,1997 rather than December 12,1997 as stated in various places in the report.
l
\
l l
l l
i l
1 I
i
\
NORTHERN STATES POWER
SUMMARY
REPORT INSERVICE INSPECTION PRAIRIE ISLAND UNIT 1,1997 TABLE OF CONTENTS l
l CONTENTS PAGE (S)
- 1. Summary 2 l
- 11. Form NIS-1, Owner's Report for Inservice inspections 3 Ill. Form NIS-2, Owner's Reports for Repairs or Replacements 34 APPENDICES PAGE (S)
A. Interval 3 Period 2 examinations by ISO 10 B. Interval 3 Period 2 examinations by ASME Item number 10 C. Interval 3 Period 2 examinations by Inspection Report number 10 D. List of section XI VT-2 Examinations 1 E. Results of Steam Generator Eddy Current Examinations 56 F. List of Snubber Inservice Testing 1 G. Interval 3 Period 140 Month Reactor Vessel Examinations 5 l
1 l
i l l
NORTHERN STATES POWER
SUMMARY
REPORT l INSERVICE INSPECTION PRAIRIE ISLAND UNIT 1,1997 l
- 1. Summary Page 1 of 2
1.0 INTRODUCTION
l The Praine Island Nuclear Generating Plant Unit 1 refueling outage began October 18,1997 and ended December 12,1997.
This summary report will convey the components examined, the examination methods used, t
the examination number and summarizes the examination results performed during the 2nd period of the 3rd interval, (Cycle 18) see appendix A, B and C. Appendix G contains the 1st period Reactor Vessel 40 month exams. The 3rd interval, 12-17-1993 to 12-16-2003 is based on the examination requirements of the ASME Boiler and Pressure Vessel Code Section XI,1989 Edition no addenda.
2.0 PERSONNEL Visual and nondestructive examinations were performed by Northern States Power (NSP),
Lambert Macgill and Thomas (LMT), Wesdyne International, Inc., Zetec, Inc. and Rockridge )
Technologies, Inc. personnel. Hartford Steam Boiler Inspection and Insurance Company, I l
provided the Authorized inspection. Certifications of examination personnel are maintained on file by Northern States Power Company.
3.0 INSPECTION
SUMMARY
Appendix G contains the results of the First period 40 month reactor vessel exams, performed by Wesdyne International. Rules of IWB-2412 for decreasing or extending a period by as much as one year to enable an inspection to coincide with an outage was invoked for this exam. ]
During the refueling outage 100% of all accessible tubes in steam generator 11 and 12 were ,
examined full length as part of the inservice inspection. See appendix E for details.
Hanger and component support examinations listed in appendices A through C as F-A include the applicable examination requirements of ASME Section XI Subsection IWF. Code i case N-491 was implemented.
Results of the examinations indicate that the integrity of the plant systems have been maintained
l NORTHERN STATES POWER
SUMMARY
REPORT 1 lNSERVICE INSPECTION PRAIRIE ISLAND UNIT 1,1997 l
- 1. Summary (continued) Page 2 of 2 4.0 EXAMINATION REPORTS, EQUIPMENT AND MATERIALS Examination reports contain references to procedures, equipment and materials used to complete the specific examinations. Copies of the examination reports, examination procedures, and equipment records are available at Northem States Power Company.
This summary report contains several abbreviations which are identified below; (A) = Augmented examinations BL = Baseline examination GEO = Geometry, eva!uation of a indication HELB = High Energy Line Break IN = Information Notice IND = Indication requires further evaluation NAD = No Apparent Defects NC = Non Code examinations NCR = Nonconformance Report OEA = Operating Experience Assessment R1, R2 etc. = consecutive examinations following repair, rework or evaluation of a initial exam SE = Safety Evaluation TS = Plant Technical Specifications 1
1 I
l l
.____ _ __________________-_ D
NORTHERN STATES POWER
SUMMARY
REPORT INSERVICE INSPECTION PRAIRIE ISLAND UNIT 1,1997 1
- 11. Form NIS-1 Page 1 of 3 FORM NIS-1 OWNER'S REPORT FOR INSERVICE INSPECTIONS As required by the Provision of the ASME Code Rules
- 1. Owner: Northern States Power Company Address: 414 Nicollet Mall, Minneapolis, MN 55401
- 2. Plant: Prairie Island Nuclear Generating Plant Address: 1717 Wakonade Drive E. Welch, MN 55089
- 3. Plant Unit: I 4. Owner certificate of Authorization: NA
- 5. Commercial Service Date: 12-16-73 6. National Board No. - NA
- 7. Components
- (See appendices for components inspected this outage)
Manufacture Component or Manufacture or Installer State or National Appurtenance or Installer Serial No. Province No. Board No.
REACTOR VESSEL CREUOT-LOIRE 688 MINN 200-51 -
PRESSURIZER WESTINGHOUSE 1111 -- 68-20 STEAM GEN WESTINGHOUSE 1101 - 68-24 (
NUMBER 11 STEAM GEN WESTINGHOUSE 1102 - 68-25 NUMBER 12 REACTOR COOLANT WESTINGHOUSE W515 - -- !
PUMP 11 REACTOR COOLANT WESTINGHOUSE W516 - -
PUMP 12 RHR HEAT JOSEPH OATS 1817-1 A -- 340 EXCHANGER 11 & SONS JOSEPH OATS 18171B - 341 RHR HEAT EXCHANGER 12 & SONS RHR PUMP 11 BYRON JACKSON -
RHR PUMP 12 BYRON JACKSON -
l SAFETY INJECTION BINGHAM -
PUMP NUMBER 11
$ORTHERN STATES POWER
SUMMARY
REPORT INSERVICE INSPECTION PRAIRIE ISLAND UNIT 1,1997
' Page 2 of 3 FORM NIS-1 OWNER'S REPORT FOR INSERVICE INSPECTIONS As required by the Provision of the ASME Code Rules l
- 7. Components: (continued) l Manufacture Component or Manufacture or Installer State or Na'tional Appurtenance or Installer Serial No. Province No. Board No.
SAFETY INJECTION BINGHAM - -- -
PUMP NUMBER 12 ACCUMULATOR DELTA SOUTHERN 41038-70-1 - 2554 TANK 11 ACCUMULATOR DELTA SOUTHERN 41038-70-2 - 2555 TANK 12 BORIC ACID NAVCO - - -
TANK 11
- 8. Examination Dates 03-03-1996 to 12-12-1997.
- 9. Inspection Period identification: 1 and 2 i 10. Inspection Interval identification: from 12-17-1993 to 12-16-2003.
- 11. Applicable Edition of Section XI 1989 Addenda none l 12. Date/ Revision of inspection Plan: 07/06/95 / Revision 1
- 13. Abstract of Examinations and Tests.
See appendices A through G (attached) l 14. Abstract of Results of Examinations and Tests.
l l See appendices A through G (attached)
- 15. Abstract of Corrective Measures.
All unacceptable indications detected have been documented on the plant nonconformance reports and have been dispositioned to assure continued plant operation integrity.
1 L_ __
l NORTHERN STATES POWER
SUMMARY
REPORT INSERVICE INSPECTION PRAIRIE ISLAND UNIT 1,1997 Page 3 of 3 l
FORM NIS-1 OWNER'S REPORT FOR INSERVICE INSPECTIONS As required by the Provision of the ASME Code Rules l We certify that a) the statements made in this report are correct b) the examinations and tests meet the Inspection Plan as required the ASME Code,Section XI, and c) corrective measures taken
' conform to the rules of the ASME Code,Section XI.
Certificate of Authorization No. (if applicable) k Expiration Date
~
Date lo k 191 Signed 1 ~
- By hk .
'(Owner)
CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, hold a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of b in A F SOf4 and employed by Ne bd$bm b er Id of #io / rk , C 0 r14 . have inspected the component's described in this Owners Report during the period of 3 96 to / 3 ' O C/ 7 and state that to the best of my knowledge and belief, the Owner has performed examinations and tests and taken corrective measures described in this Owners Report in accordance with the Inspection Plan and as required by the ASME Code,Section XI.
By signing this certificate neitbr the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations, tests, and corrective measures described in this Owners Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
$we / Commissions bh [f ' / 7V National Board, State, Province and In!ipectors Signature i
' i Endorsements Date: d et b [b 199k
- i
! NORTHERN STATES POWER
SUMMARY
REPORT INSERVICE INSPECTION PRAIRIE ISLAND UNIT 1,1997 l
Ill. FORM NIS-2 OWNERS REPORT FOR REPAlRS AND REPLACEMENTS Seventeen Form NIS-2s are attached which identify plant system repairs or replacements that have been completed at Prairie Island Unit 1 between the dates of 03-03-96 to 12-12-97, l
I .i l l l
l FORM NIS 2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
- 1. owner Northern States Power Co .
u.m.
osse 8!f f 1717 Wakonade Dr. E, Welch, MN 55089 sheet / of M Addreas
- 2. Plant Prairie Island a
. Unit ! l n.m. j Same Wor X- O r ch r ; 870 WO/ l Address FL.pelr Organization P.O. No., Job No., etc.
- 3. Work Performed by Ovner Type Code symbol stamo A/4
- Authorization No, MN Expiration Date MN 1
Address
- 4. Ident!ftestlo of System M IMO w h Of1m .
- 5. (a) Applicable Construction Code h9 N Edition, Addenda- Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 1
- 6. Identification of Components Repelred or Replaced and Replacement Components ASME Code Repaired, Stamped National Other Year . Replaced, (Yes Name of Name of Manufacturer Board Identification Built or Replacement or No)
Component Manufacturer Serial No. N o.
// Ce m g C./s (c4G 9 3'l Y ua + ea YuBA -i A 12'10 /3f-o3t 4@ 8eP n rd C- 4 0 f- 9 0 8 K4 f W
- 7. Desertation of Work J
- 8. Test Conducted: Hydrostatic 0 eneumatic 0 nominai operaiias Pressure 3 Other Pressure I/O psi Test Temp. /00 *F f
NOTE: Supplemental sheets in form of tists, sketches. or drawings may be used. provided (11 size is 8% in. x 11 in.. (2) informa-tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is nurnbered and the number of sheets is recorded at the top of this form.
(12/82) This Form (E00030) may be obtained from the Order Dept.. ASME. 345 E. 47th St..New York, N.Y.10017
l-f l
1 i
! $MEEr l JP I?
l l
FORM NIS 2 (Back)
Memerks Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLlANCE ..
We certify that the statements made in the report are correct and this I conforms to the rules of the
'***i' rept coment ASME Code,Section XI.
Type Code Symbol Stamp 1
Certificat Authorization No. M Expiration Oste Signed _
b Date Y 19 Owner of Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION i, the undersigned, holding valid commission issued by the National Board pf Boijf r and Pressure essel inspectors and the State or Province ofvi(nat ^ ^ri^t fs: a[tA Y Nndasem oy by or oed [Tt*o m N /I C" 1CE of 1
t e, hut # b ei O have inspected the components described in this Owner's Report during the period ~3 h to /2"I2 ~ 0 7 and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any menner for any persons!injug or property damage or a loss of any kind arising from or connected with this inspection, u Commissions National Board. State, Province, and Endorsements
'/ inspector's Signature Daie 3- /O - 7 6' ,, __ 9 f r
i i
l FORM NIS 2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
- 1. Owner Northern States Power Co. oote 3 Nom. .
3717 Wakonade Dr. E, Welch, MN 55089 sheet M of / ~/
Address
- 2. Plant Prairie Island' . Unit /
Name same 606 - ic O' h < ' 97/B76P' Addrone Ptepair oreenlaetion P .O. No., Job No., etc.
- 3. Work Perfor. *<i'.sy Owner Type Code symbol stamp ^M N'** Authoriastion No. NN Expiration Date N Address
- 4. Identification of System . f. S r af f 444 o V A f
- 6. (e) Applicab'le Construction Code 6 N-- 19 N Edition, Addende- Code Case (b) Applicable Edition of Section XI Utilized for Repelrs or Replacements 19 U
- 6. Identification of Components Repelred or Replaced and Replacement Components ASME Code Repelred, Stemped National Other Year Replaced, (Yes Nome of Name of Manufacturer Board Identification Bullt or Replacement or Nol Component Manufacturer Serial No. N o.
/A MJ,duc(
% +- G Le L hSspL t'Lh /E'l7-IB HA /3C-C S2.- 69 Reine Y 1
- 7. Description of Work (A h b ou- 1 Md lVL L% W 1
l B. Tests Conducted: Hydrostatic Pneumatic 0 Nominal Operating Pressure O AlA psi Test Temp. *F l Other O Pressure NOTE: Supplemental sheets in f orm cf lists, sketches, or drawings may be used, provided til site is 8% in. x 11 in., l2) Informe, tion in Items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded et the top of this form.
(12/82) This Form (E00030) may be obtained from the Order Dept., ASME,345 E.47th St., New York, N.Y.10017 l
1 L_ _ _____ _ ______ _. -_
i S nen 2 m: / 7 FORM NIS 2 (Back)
- 9. Romerks Applicable Manufacturers Data fleports to be ettsched
~ . . . .
f CERTIFICATE OF COMPLIANCE I We certify that the statements made in the report are correct and this MM l# conforms to the rules of the
*I#'*****"' I ASME Code,Section XI.
Type Code Symbol stamp Expiration Oste Certifice f Authorirstion No.
Sign. * *i ~
Il-- W Date *'
' 19N '
' ' Owner or Owner's D.s,enee. Titid CERTIFICATE OF INSERVICE IN'iPECTION V
1, the undersigned, holding a vali commission issued by the National Bpard gf Botter I andrr Pressurfe essel or inspectors a or Province og V t rt n f 5 n c. and employed by Y0 ** To '" d $bf"^ Boi have inspected the components described o#T o ' cf b o *16 in this Owner's Report during the period 3*3'Yb to /1"I2*97 . and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in th Owner's Report in accordance with the requirements of the ASME Code,Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personalinjury or property damage or a loss of any kind arising from or connected with th Inspection.
~
Commissions /
....e..s.s......In....n e n..r... .n.s v .n.oecs.~. . sn.s.,e ..t..n..
Date 19 I
l
FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
- 1. owner.liorthern States N.mo Power Co. oste 3/5/W 1717 Wakonade Dr. E, Welch, MN 55089 heet S of Addr
- 2. Plant Prairie IslandN.me . Unit !
Same Morg Ordes - 9W2037, 9 7/2Oy Repair Organization P.O. No., Joli Nn., etc.
Address Type Code symbol Siemp A/ 4
- 3. Work Performed by Owner MM Nonw Authorization No.
Expiration Date Al O Address 0M
~
- 4. Identification of System . Md2 i A
/* ! _19 NEdition, Addende. Code Case
- 6. (e) Applicable Construction Code _.
(b) Applicable Edition of Section XI Utillred for Repelrs or Replacements 19 k7
- 6. Identification of Components Repelred or Reptoced and Replacement Components ASME Code Repaired, Stemped National Year Replaced, (Yes Nome of Manufacturer Board Other Name of Built of Replacement or No)
Component Manufacturer Serial No. No. Identification f
rN t ~
AJ A- AlA NA 30-ms-2 L7 Rep t < A]
s k o e L a c.
dtumh7 nO gn uJ c,l d
- 7. Description of Work &ME O IW
- 8. Tests Conducted: Hydrostatic 0 Pneumatic 0 Nominal Operating Pressure O psi Test Temp. 'F M A' Other O Pressure _
NOTE: Supplemental sheets in form of lists. sketches, or drawings may be used, provided (11 size is 8% in. x 11 in.
I tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number o recorded et the top of this f orm.
(12/82) This Form (E00030) may be obtained f rom the Order Dept., ASME,345 E. 47th St., New York, N.Y.10017
I I
1 S iner 3 of / 7
, FORM NIS 2 (Back)
Some indsmErmr,
- s. nemerks Mor t ' or-E <-Applicable 9 '7/Ao37 remow d Manufacturer's Data Reports to be attached (A % r X. Os- d < e- 99 (Ala.'1 t-e m o u. L Me r-e m a m E v . rm.A-c.(
iC. M M I A P f. N 4 e t W A.I M. b0 J C A o m s r's A CERTIFICATE OF COMPLlANCE N I conforms to the rules of the We certify that the statements made in the report are correct and this
8*"P'*****"*
ASME Code,Section XI.
Type Code Symbol Stamp Expiration Date Certificabf Authorization N b Date 19 I Signe' d' i
~
Owner or Owner's Destones, Title' CERTIFICATE OF INSERVICE INSPECTION 1, the undersign , holding a valid commission issued by the National B ard of oiler and Pressure Ve I inspectors and the St or Provin e of In M3 6 54 and employed by N0* hW S Yt'Q ^ l$ 0 0 F" 5[5 of have inspected the components described a 'Nf# e OO6A i
in this Owner's Report during the period N'3'ib to / 2
- I) ' 7 . and state that to the best of my knowledge and belief, the Owner has performed er aminations and taken corrective measures described Owner's Report in accordance with the reautrements of the ASME Code,Section XI.
By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, conc examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employe shall be liable in any manner for any persons! injury or property damage or a loss of any kind arising from or connecte inspection.
~
Commissions .n.o,.. .n.s r
- N. n ..s o,. s . ,,n..u,. ..t..n.l ...r......e..,..!_ ...n.
i os,, %-/0 3, 97 .
)
FORM NIS 2 OWNER'S REPORT FOR REPAlRS OR REPLACEMENTS l
As Required by the Provisions of the ASME Code Section XI o ,1, 3 f
- 1. Owner Northern States No..
Power Co. ,
1717 Wakonade Dr. E, Welch, MN 55089 sheet '
of M Address unit [
- 2. Plant Prairie Island Nome Same b]ne k Ov L ,s
- 92/91M.
Repolt Orgentsetton P.O. No., Job P40., etc.
Addrses Type Code symbol stamp M
- 3. Work Performed by Own e r- NN N "* Authoritetton No.
Expiration Date M#
Adorses M4tn "A
- 4. Identification of System -
- 5. (n) Applicable Construction Code ! 19 d Edition, Addenda, Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 N
- 6. Identification of Cornponents Repelred or Reptsced and Replacement Components ASME Code Repaired, Stamped National Replaced, (Yes Year Manufacturer Board Other I Phme of Name of Built or Reptocement or No!
M No. No, identification Component Manufacturer
- Medd (Y10m Skm 4s 2 5-/S # Rehud Al rb A-r As at Pmd 9w W tJ ik O ow^ k 7 -
~
Y !'
- 7. Description of Work e/[AL 0 l
B. Tests Conducted: Hydrostatic O rneum tic 0 Nominst Operating Pressure @
f T*>< Tema- Wo 'r asi l
Other O Pre >>=re- /ooo NOTE: Supplemental sheets in f orm of lists, sketches, or drawings may be used, provided (11 size i is 8% in I
tion in itemt 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the recorded at the top of this form.
112/82)
Th; Form (E00030) may be obtained from the Order Dept., ASME,345 E. 47th St., New York, N.Y.10 l
l l
l ; ,
l l
l i-l i
O NS(f FORM NIS 2 (Back)
- 9. Remarks Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLlANCE ..
We certify that the statements made In the report are correct and this M f2 ** '- conforms to the rules of the -
ropad of replacement ASME Code.Section XI.
Type Code Symbol Stamp d Certificate % Authorization No. -
Expiration Date N Signed f b8* ate bY
19 O dwner or Owners De.ignes, Title l
CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the Nati nal B ard of oiler a d Pressure essel Inspectors and the Stata or Province of NIMfif56Ya and employed by O' Mc C*o A 0I of D d [0 M . O O 31 O have inspected the components described j in this Owner's Report durfng the period ~3' to /2 ~7 and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.
By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind a.ising f rom or connected with this inspection.
h
~
- Commissions y in euor.si n.iu,. u.uon. ...ra. si.i.. rro.inc.. .na e noor..moni.
~
Date 19
l t
FORM NIS.2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS l As Required by the Provisions of the ASME Code Section XI
- 1. Owner Northern States Power Co.
N.m.
oete 3.!9 97 1717 Wakonade Dr. Er Welcht MN 55089 heet S of
~ Address
- 2. Plant Prairie _Tsland . Unit Name Same MoeiL O rdtc : 9919M9 flopear Orgenlaation P.O. No., Job No., etc.
Addross
- 3. Work Performed by Owner Type Code Symbol Stamp A> A
"*** Authorization No. A/ O Expiration Date M Address
~
- 4. Ident( ; ation of System . MA** AM !
- 6. (e) Applicable Construction Code [ N I 19 N Edition, Addends. Code Case (b) Applicable Edition of Section XI Utiltred for Repairs or Replacements 190
- 6. Identification of Components Repelred or Replaced and Replacement Components ASME Code Repaired, Stamped National Year Replaced, (Yes Name of Name of Manufacturer Board Other Bullt or Replacement or No)
Component Manufacturer Sanal No. No. Identification '
/M0D2I Met m SW m f v4 2 s -/t-L nA Pep %nd Al Ar w e Powe. I( 9061we l
- 7. Description of Work M f (4 CC S Vb B. Tests Conducted: Hydrostatic 0 Pneumatic 0 nominai over.iian Pressure O Other O Pressure /oo o asi Test Temp. Wo 'r ;
f NOTE: Supplemental sheets in f orm of lists, sketches, or drawings may be used provided (1) size is 8% in. x 11 in., (2) Info tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of she recorded at the top of this form.
(12/82) This Form (E00030) may be obtained from the Order Dept., ASME,345 F. 47th St.,New York. N.Y.10017
{
l
I r
l l
Snew 5 o' O
~
FORM NIS 2 (Back) 1
- 9. Romerks ;
Appilcable Manufacturer's Date Reports to be etteched I l
l l
CERTIFICATE OF COMPLIANCE If O!CCA N conforms to the rules of the We certify that the statements made in the report are correct and this repair'or repiscement ASME Code,Section XI.
Type Code Symbol Stamp Expiration Date _
Certifica of Authorization No.
Sign $^^^^e -
S O Date 19 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION card of oile a d Pressure esset inspectors and the State t, the undersigned, holding a valid ommission issued by the Nati nal b/ T of NM/MSo 4 and employed by_ de b^ F4 A or Province of Ho 4 4J , eonn. hoe inspected ine components described
/'O* 7
~3* b to and state that in this Owner's Report during the period _
to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures describ Owner's Report in accordance with the requirements of the ASME Code,Section XI.
By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, con examinations and corrective measures described in this Owner's Report, Furthermore, neither the inspector nor his emplo shall be liable in any manner for any personal infury or property damage or a loss of any kind arising f rom or connec inspection.
/M A Commissions National Board, State, Province, and Endorsements i
"/' Inspector's Signature l Oste 19 h E
FORM NIS 2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI cate_ 3 98-
- 1. ownernorthern States Name Power Co.
1717 Wakonade Dr. E, Welch, MN 55089 sheet b of /7 Address
- 2. Plant Prairie Island
. Unit . !
Narne same W' 97//3'7 Repear orgentretion P.O. No., Job No., etc.
s Address Type Code syrnbol stamp A/ 4
- 3. Work Performedby Owner MN
"*** Authorization No.
Expiration Date M Address Oi^ ^
- 4. Identification of System .
- 6. (e) Applicebte Construction Code 5WJ is d . Edition.
~
Addenda _ Code Case (b) Applicable Editlen of Section XI Utilized for Repairs or Reptocements 19 D
- 6. Identiftestion of Components Repaired or Reptoced and Replacement Components ASME Code Repsired, Stamped National Rep' seed, (Yes Board Other Year Name of Name of Manufacturer or Rep acement or No)
No. Identification Built Component Manufacturer Serial No.
NS t) b NA h A4) 6f AA D{ AL9e%
f-O)$k * /QL{&
i
(
E9 A fE #Or 1
- 7. Description of Work
- 8. Tests Conducted: Hydrostatic 0 eneumatic 0 Nominai Oaersiins Preiiure O M A psi Test Temp. 'F Other] Pressure NOTE: Supplemental sheets in form of lists, sketches, or drawings rnay be used, provided fh tili size is 8%
tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the riu recorded et the top of this form.
This Form (E00030) rnay be obtained from the Order Dept., ASME,345 E. 47th St., New Vork, N (12/82) l I
E_ _ _ _
b/[(C[
FORM NIS 2 (Back)
Remarks Applicable Manufacturer's Osta Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made lo the report are correct and this l' '
dCW8 nforms to the ru s o' f the ASME Code, Section Xl.
Type Code symbol Stamp Certificate f Authorization No. Expiration Date Signed , Date 3* f 3, #
owner or owner's Designee, Titi/
CERTIFICATE OF INSERVICE INSPECTION holding a valid e mmission issued by the Natio al Bo rd of Bo I r and P essure Vesse insppctors and the State 1, the undersigned,b HM 75 0 4 and employed by or Province of w hv. $ #o a O t fr a- 1f of N a N[o r d , ( O M #1 have inspected the components described in this Owner's Report during the period b to I1' ~i7 . and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
~
I Commissions reatione emera state. Province, and Endorsements
/~ in w ector": signetwee Date 19 l
l 1
t- _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
l I
FORM NIS 2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
- 1. Owner Northern States Power Co. Date 3 '
Name 1717 Wakonade Dr. E, Welch, MN 550895 heet 7 or /7 Aodress
- 2. Plant Prairie IslandName . Unit !
l Same Mrk M u ** U */A/CY Repelt Orsenisetton P.O. No. Job No., etc. j Adorsee Type Code symbol stamp
" A/O f
- 3. Work Performed by Owner f N "* Authorization No, M '
Expiration Date MN Address
- 4. Identification of System . tac e o G I
- 5. (e) Applicable Construction Code *! 19MEdition, "
Addends, Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacement 19 f 7
- 6. Identification of Components Repelred or Replaced and Replacement Components ASME Code Repaired, Stamped National Year Replaced, (Yes Name of Name of Manufacturer Board Other Built or Replacement or No) l Component Manufacturer Serial No. No. Identification l A/ A [a-/.C-/V8 b7 MA ^!
//<- AJ A A/ A-l l
I i
O T C- F5 C
- 7. Description of Work (4 h b C c4-
- 8. Tests Conducted: Hydrostatic 0 eneumatic0 NominalOperating Pressure O M A psi Test Temp. 'F Other O Pressure _
NOTE: Supplemental sheets in form of lists, sketches. or drawings enay be used. provided (1i size is 8% in. x 11 in., (2) tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the numbe recorded at the top of this form.
(12/82) This Form (E00030) may be obtemed from the Order Dept., ASME,345 E. 47th St., New York, N.Y.10017
g c~-j~ 05 FORM NIS 2 (Back)
- 7. Remarks Appilceble Manufacturer's Data PLoports to be ettsched CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct end this' NMI conforms to the rules of the repair of replacement ASME Code,Section XI.
Type Code Symbol Stamp Certificate Authorization No, Expiration Date Signed b -
N be" Date b ' '
O 19 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned holding a valid mmisalon Issued by the Na nal B ard of oil d Pressur es inspectors and the State or Provinc of f H #1 f T 0 0 and employed by 4e [O' 4A &1 Ye $ of dNbrd , O eH r) have inspected he components described
~ ~
in this Owner's Report during the period to I and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI, By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the ,
examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector not his employer !
shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this insection.
Commissions / ~
National Board, State, Province, and Endorsements
- / taspector's signature Date 19_
l l
I FORM NIS.2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI case 3 I 9I
- 1. Owner Northern States Power Co .
1717 Wakonade Dr. E, Welch, MN Name 55089 heet S b of N Addreas Unit /
- 2. Plant Prairie Island Name Same (DoeL Mu ' 9 7/2 5W Repelf Orgenlastion P.O.No., Job No., etc.
Addrous Type Code symbol stamp
' Mb
- 3. Work Performedby Owner Name Authorization No.
Nb Expiration Oste MN Address
- 4. Identification of Systern RWM [a =d
~
S. (el Applicable Construction Code b' / 19 07 Edition, D
Addends; Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19
- 6. Identifiestion of Components Repelred or Replaced and Replacement Components ASME Code Repaired, Stamped National Replaced, (Yes Board Other Year Name of Name of Manufacturer or Reptocement or No)
No, ledentification Bullt Component Manufacturer GeseeM4o.
Mdl RYb ouwt NS 0 fatud ^
\Jett a1 UC)an b-GSg N$ $ 0. & l A
W*
- 7. Description of Work I
- 8. Tests Conducted: Hydrostatic Q Pneumatic 0 Nominal Operating Pressure O l a'i Teit Tema fV7 'F I Other O Pressure 4*o NOTE: Supplemental sheets in form of lists. sketches, or drawings rnay be used,fh provided is (1) size tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is nurnbered and th recorded et the top of this form.
l This Form (E00030) may be obtained from the Order Dept., ASME,345 E. 47th St..New York 1 (12/82)
? !
- 1 L___________
Swer T oi= / 7 FORM NIS 2 (Back)
. Remarks Applicant Manuf.cturer as osta neports to de ets.ch.d CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this N 8 conforms to the rules of the ASME Code Section Xf.
Type Code Symbol stamp b
Certifi t of Authorization No.
N Expiration Date
~. Date 19 Signed rU
- Owner or Owner's Designee, Titl6 CERTIFICATE O F INSERVICE INSPECTION 1, the undersigned, holding a valid cgmmission issued by the Nati 1 nalbG B ard A ofb#I B iter andIPressure Vesselof Inspectors or Province of b i M /I t'S O F 4 -and employed by G# ^*"
No [6'd , bD *1 M have inspected the components described in this Owner's Fieport during the period 3 - _4 b to Il'O* end state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code Section XI.
By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the l examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer f shalt be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
~
l Commissions National Board, State, Province, and Er dorsements Inspector's' Signature V/
Os,e 3 /o ,, n I
j
l
(
l
\
' FORM NIS.2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Previsions of the ASME Code Section XI 1, owner Northern States Power Co. o ,,, 3 9[ ;
N o,n.
of !
1717 Wakonade Dr. E, Welch, MN 55089 Sheet _
' Address
Unit !
2 Plant Prairie Island .
Name (Jor /C O r cle < : Do /330 Same Repair Orgentastion P.O. No., Job No., etc.
Address Type Code symbol Stomp Mb
- 3. Work Performedby_ Owner Narne Authorization No.
MO Expiration Date Mk I A dress r" 00f aw /T m
- 4. Identification of System . QA C Addenda _ Code Case 19 Edition,
- 5. (s) Applicable Construction Code (b) Appitcsble Edition of Section XI Utilized for Repairs or Replacements 19
- 6. Identification of Components Repelred or Replaced end Replacement Components l
ASME Code Repaired, Stamped l
National Replaced, (Yes Other Year Manufacturer Board or Replacement or Nol l Name of Name of Identification Built Serial No, N o.
Component Manufacturer 1
l I K w+ et. s t- p M* MA ^/
Pu- c LuMe /J A M-or/
l i
I l
b M A LN
- 7. Description of Work #!O I' l
- 8. Tests Conducted: Hydrostatic Pneumatic 0 Nominal Operating Pressure @
Test Temp. SW *F Other O Pressure MV _ psi NOTE: Supplemental sheets in f orm of lists, sketches, or drawings d the may number be used, of sheets is provid tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered an recorded at the top of this form.
This Form (E00030) may be obtained from the Order Dept.. ASME,345 E. 47th St.,
(12/82) 9 2
l l ,> 'u I
km- nt 7 -
FORM NIS 2 (Back) i
- 9. Remarks Applicable Manufacturer's Oste Reports to be attached 4
)
CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this W ob O conforms to the rufes of the repair be raptacernent !
ASME Code,Section XI.
l Type Code Symbol Stamp Nk Expiration Date AI Certificate f Authorization N Signed M (M! ' b CO3"d Oate 59 '
' 19 f P' Owner or Owner's Designee, Tifle '
CERTIFICATE OF INSERVICE INSPECTION l l
l, the undersigned, holding a valid c mmission issued by the Nat nal oard of iter and Pressure snelI spectors and the State or Province of IU l M / 1" 5 e 6 and employed by & Se oW 6i c e- 16 of have inspected the components eescribed He..-O J > co s a in this Owner's Report during the period 3-34S to / 3 ~ /A ~ 9 7 and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.
By signing this certificate neither the inspector nor his employer makes any warranty, expresse' d or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personalinjury or property damage or a loss of any kind arising from or connected with this inspection.
- / Commissions Nations! Board, State Province; and Endorsements Inspecto7 s ingnatuTo V/ !
Date 19 i
FORM NIS 2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI 1, owner Northern States Power Co. oste 3 -
N.m.
1717 Wakonade Dr. E, Welche MN 55089 heet S /0 of d j Address
- 2. Plant Prairie IslandName . Unit [
Same uk Ork d%: 97l239/ / 97/2#1 Ptepair Orgennration P.O. No., Job No., etc.
)
Address l Type Code Symbol Stamp Mk
- 3. Work Perforrned by Owner Narne Authorization No. A/N Expiration Date MO i Address
- 4. Identification of System . Slcom b em k.- -
~
- 6. (e) App!! cable Construction Code ecf 19dEdition, Addenda, Code Case I (b) Applicable Edition of Section XI Utillred for Repairs or Replacements 19 89
- 6. Identification of Components Repelred or Replaced and Replacement Components f I
l
! ASME f i
! Code i l Repairedf Stamped National Year Replaced, (Yes Name of Manufacturer Board Other Name of or Reptocement or No)
Serial No. N o. Identification Built Component Manufacturer lS a rmorYV bksb e NO N r/CS $l kepas r-I l
t 7 Description of Work fY\Qc.Atne 9 A 4 (C b buf b CCa5 5CC0N ON $t* C-V I
- 8. Tests Conducted: Hydrostatic 0 Pneumatic 0 Nominal Operating Pressure @
Other O Pressure /@O _ psi Test Temp. WO 'F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8% in. x 11 in., (2 tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number o recorded et the top of this form.
112/82) This Form (E00030) may be obtained f rom the Order Dept.. ASME,345 E. 47th St., New York, N.Y.10017
, e l
4 1
i
! I I
t
$ MEET lD W l t
i FORM NIS 2 (Back)
MGLCbi no d hai d b (( Ow1 Ma w wa., % rNACAs -
- 9. Remarks l Applicable Manufacturer's Data Reports to be attacfod l
W ^ S D 0 e* Se $ L Pee Ldo tSt n tk cu t n Gus r de- L o \
y .. - . - . .
CERTIFICATE OF COMPLIANCE NN t# conforms to the rules of the We certify that the statements made in the report are correct and this '
"P'#"P'***"'*"*
ASME Code,Section XI, Type Code Symbol Stamp N
& Expiration Date _
h Certifi t of Authortration Date 19 Sign J M* -- "
' Owner or Owners Designee Titief
- CERTIFICATE OF INSERVICE INSPECTION rd of Boiler and Pressor Ves I inspect rs and the State !
1, the undersigned holding a valid commission issued by the Nati nel W WOW 0I II of or Provin of biH vt n e Y4 and employed by.
have i ected the components described W N o ' d , O O a #1 3~U b to. /2~ ~77 , and state that in this Owner's Report during the period.
to the best of my knowledge and belief, the Owner has performed examinations and taken corrective meas Owner's Report in accordance with the requirements of the ASME Code,Section XI.
By signing this certificate neither the inspector nor his employer makes any warranty, expressed or i examinations and corrective measures described in this Owner's Report. Furthermore, neither d with the this inspecto 1 hall be liable in any manner for any personalinjury or property damage or a loss of any kind arising from or conn inspection.
N Commissions National Board, State, Province, and Endorsernents
- / Inspectors Signature Date
~
D 1g @ $
1 l
l 1
l FORM NIS.2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI 1 owner Northern States Power Co. o t. 3 ft*
Nome 1717 Wakonade Dr. E, Welch, MN 55089Shee't // of /7
' Address l
- 2. Plant Prairie Island"*** . Unit O,. J e r. s ** 9762 VWf w o ic.
h a '4 V , M / 2 .s P v' I
Same Repair Orgentretton P.O. No., Job No., etc.
Addreas Type Code symbol stamp MN
- 3. Work Performed by Owner Nerne Authorlistion No. Mb Expiration Date M Address
~
- 4. Identification of System - b^ fMf b f
- 6. (a) Applicat le Construction Code _ b8-Cf 19N Edition, Addende. Code Case E9 (b) Applicable Edition of Section XI utilized for Repairs or Replacements 19
- 6. Identification of Components Repelred or Replaced and Reptocement Components ASME Code Repelred, Stamped National Year Replaced, (Yes Name of Name of Manufacturer esard Other Bullt or Replacement or No)
Component Manufacturer Serief No. No. Identificat}on N M e t' bC54 sum- NA . r e c. 3 N e. pair
- 7. Description of Work
- 8. Tests Conducted: Hydrostatic Pneumatic 0 Nominet Operating Pressure @
asi Test Tema. KVO 'F Other O Preiiure /ooo NOTE: Supplemental sheets in form of lists, sketches. or drawings may be used, provided (1) size is 8% in. x 11 in., (2) Info tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of she recorded at the top of this form.
f I (12/82) This Form (E000301 may be obtained f rom the Order Dept., ASME 345 E. 47th St., New York, N.Y.10017 l
l i
(
i-Es=er // of I 7 FORM NIS 2 (Back) i S8 44n des e a s
- 9. Remarks d: M. h bhbeIL O Ad Ma^Wk 30 ACC 5 ~
Applicable Manufacturer's Dets Reports th be ottsched (
S J c. p e r- 0)L.s4me L.m.9t c h daw w
- I , , ,
i CERTIFICATE OF COMPLlANCE -
We certify that the statements made In the report are correct and thisrepair or replacement N IF conforms to the rules of the l
ASME Code,Section XI.
Type Code Symbol Stamp '
Al & Expiration Date Al k Certificht' of Authorization N Signed}h /d . L l -'Z I b d oa,e 34
,f, 95 W Owner or Owners Designee, Titid CERTIFICATE OF INSERVICE INSPECTION d of oiler and Pressur Ve I inspectors and the State 1, the undersigned holding a valid commission issued by the National M bob and employed by N O
' 4" #/ U bE- of or Province of have inspected the components described Nd N hd > b O d *1
/2'O*E7 . and state that in this Owner's Report during the period. 1'3'7b to to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures Owner's Report in accordance with the requirements of the ASME Code.Section XI.
By signing this certificate neither the inspector nor his employer makes any warranty, expressed or im examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector shall be liable in any manner for any personalinjury or property damage or a loss of any kind arising from or I inspection.
~
Commissions . ...o n .. . o . ...... p,o. n.. .no . no .,s._, s ,
y , n.o..t.,s ...n.tu,e oste 9 -/O fS 97 l
I
4
.. , l l
i l
FORM NIS 2 OWNER'S REPORT FOR REPAlRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
- 1. Owner Northern States Power Co. osse 3 Name 1717 Wakonade Dr. E, Welch, MN 55089S heet ! of Address l
- 2. Plant Prairie IslandN.m. . Unit /
Same
/S/ % br Plu e repoA Address Repelr Orgenlastloh P.O. No., Job No., etc.
- 3. Work Performed by Owner Type Code Symbol Stamp Al4 Name Authorization No. MM Expiration Date Al N Address
- 4. Identification of System . bbM ^*
l S. (e) Applicable Construction Code b 19 d Edition, Addenda; Code Case !
(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 89
- 6. Identifiestion of Components Repelred or Replaced and Replacement Components l ASME Code Repaired, Stamped National Other Year Replaced, (Yes Name of Name of Manufacturer Board Built or Replacement or No)
Component Manufacturer Serial No. N o. Identification
}/ GS$Ca m N4 A! A
[erseS S( O ken e- Y e n e cc, & bles&kow.
Ge e. , c. e Wes4 qketc. N Scr e I f/ kua s e-1 l
l
- 7. Description of Work b% n e.e r bk h(49csvna O d 9 e.c U l ^8) e 1 l
Nominal Operating Pressure O
- 8. Tests Conducted: Hydrostatic Q Pneumatic OtherO Pressure AMO psi Text Temp. I7 'F NOTE: Supplemental sheets in f orm of lists, sketches, or drawings rnay be used, provided (1) size is 8% in. x 11 in., (2) Informa-tion in items 1 through 6 on this report is included on tach sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.
(12/82) This Form (E00030) may be obtained from the Order Dept., ASME,345 E.47th St.,New York, N,Y.10017
o .
\ ,
l L
SvserN c+17 FORM NIS 2 (Back)
%, md4 me.<, A t- k< L ob e e,n. soons~atos.beJ.soec,,.d I le e. ui m4 S . v- 11 im 1
- e. n.me,us A I 54a m w e n h rs .pomebuenuwtu,ssSete 4e,ua Au G aof Le m m < ., t-e.por+ ,
- l CERTIFICATE OF COMPLlANCE int # conforms to the rules of the We certify thet the statements made in the report are correct and this '
ASME Code, Section Xl.
Type Code Symbol Stamp b Certific t of Authorization No.
NA Expiration Date Nk Signed MA1AA*? L C- b d Date ,
,19_
Owner or owner's Designee Titl6 l
CERTIFICATE OF INSERVICE INSPECTION t, the undersigned, holding a vali commission issued by the Nat' nal B ard of oiler nd Pressure Vesse of inspectors and employed by 4' [O' b4^ 00i " I l'I or Province of NM A tS
- 4 have inspected the components described b D Mho# d , bo *t A f
in this Owner's Report during the period. 1'3
- i b to M*b and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures d Owner's Report in accordance with the requirements of the ASME Code,Section XI.
By signing this certificate neither the inspector nor his employer makes any warranty, expressed or impfie
' examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his em shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or con inspection.
O ^^^- Commissions Nat6onal Board. State Province; and Endorsements l
! /' Inspector's Signature l
~
Date 19
l l
l FORM NIS 2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI Date 3 1' Y
- 1. Owner Northern States N.m.
Power Co.
1717 Wakonade Dr. E, Welch, MN 55089 heet S ! of Adorous Unit
- 2. Plant Ptairie Island Name wo 97o&%o Same Repair organisetton P.O. No., Job No., etc.
Address Type Code Symbol Stamp
- 3. Work Performed by Owner
- Authorization No.
Expiration Data Address
- 4. Identification of System ab W\fL 4
M 19 b7 Edition, ~ Code Case f _ Addenda.
- 5. (a) Applicable Construction Code (b) Applicable Edition of Fection XI Utilized for Repairs or Replacements 19
- 6. Identification of Components Repaired or Replaced and Replacement Components ASME Code Repaired, Stamped National Replaced, (Yes Board Other Year Name of Name of Manufacturer or Replacement or No)
N o. Identification Built Component Manufacturer Serial No.
Sa Ge h Inhc W. NA NA $5A-'l MA bplaesmf hl Chec c l.ka Ia \)6L/2] 4 d" DR
- 7. Description of Work eC4hd 3 B. Tests Conducted: Hydrostatic 0 Pneumatic C Nominal Operating Pressure Test Temp. 5V7 'F Other O Pressure,2 d 3I psi NOTE: Supplemental sheets in form of lists. sketches, or drawings may be used, provided b r of sheets is (1) siz I
tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is riumbered and the n recorded at the top of this form.
(12/82)
This Form (E00030} may be obtained from the Order Dept. ASME.345 E. 47th St., Ne I
I
.. l l
i
i i
t .
yp / 5 or= l ?
FORM NIS 2 (Back)
Remarks Applicable Manufacturer's Osta Reports to be attached
.~
CERTIFICATE OF COMPLIANCE .-
We certify that the statements made In the report ses correct and this IT O!df'h nforms to the rules of the ASME Code, Section Xl, Type Code Symbol Stamp b.
Certifi f Authorization Expiration Date Signed I Date 19 Owner or Owner's Designes, Titti ( '
CERTIFICATE OF INSERVICE INSPECTION f, the undersigned holding a validjommission issued by the Nati nat o d of B iler n Pressure V sselin ectors and the State or Province of b f *181 f'S :a T
- and employed by V Oa f0 M _o/U f C of Hefro e cf , c o 4 n have inspe ed the componenis described in this Owner's Report during the period *3 b to /1'M 7 and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.
By signing this certificate neither the inspector por his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal Injury or property damage or a loss of any kind arising from or connected with this ,
inspection.
~
Comn.issions National Board. State, Province, and Endorsernents
/ Inspector's Signature l
~
Date 19 ---
l' l'
I L--_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ ,
l FORM NIS 2 OWNER'S REPORT FOR REPAlRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI i l
- 1. Owner Northern States Power Co. oete 39U '
Nome 1717 Wakonade Dr. E, Welch, MN 5 50895 heet M of /7 ;
j Address I
- 2. Plant Prairie IslandNome . Unit same dor K OM ' ' 9M Repair organization P.O. No Job No., etc.
Address Type Code Symbol Stomp ' M4
- 3. Work Performed by Ovner NN
"*'"* Authorization No.
Expiretion Date MN Ad dress O D
- 4. Identiflection of System . t ww t c. A k 6 u hn e.-
~
" Code Case
- 5. (a) Applicable Construction Code N/ 19 N Edition. Addenda _
(b) Applicable Edition of Section XI Utilized for Repeirs or Repf scement: 19 37
- 6. Identification of Components Repaired or Replaced and Replacement Compor,ents ASME Code Repaired, Stamped l Netional Year Replaced, (Yes Manufacturer Board Other Name of Name of Bullt or Replacement or No)
SeMNo. No. Identification Component Manufacturer '
MWe /
$ON 'TD IA 8 cc CWC. ll gj$ SepbumJ N Mes6e< Gdwa r d s MW3!d U C 4-// AJA
- 7. Description of Work C#
- 8. Tests Conducted: Hydrostatic @ Pneumatic 0 "ominei operatiasereisure O Other Pressure MM psi Test Temp, 70 *F I
NOTE: Supplemental sheets in f orm of lists, sketches, or drawings rnay be used, provided (1) sire is 8% in. x 11 in.
tion in items 1 through 6 on this report is included on each sheet, and 13) each sheet is numbered and the nu recorded et the top of this form.
(12/82) This f orm lE00030) may be catained f rom the order Cept., ASME.345 E.47th St., New York, N.Y.10017 l
L__-_-________
i
. r l
{ Ycc g7'- h W FORM NIS-2 (Back)
' 3.' Remarks l
Applicente uenufacturer e case neports to ne .issened
~-. - . . . ,
I l
i CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this N UPN=t onforms to the rules of the ASME Code, Gection XI, 1 Type Code Symbol Stamp Certific of Authorization P Expiration Date b Sign _ k^% - Oate "
' 19 i Owner or Owners Designee, Tftte -
l CERTIFICATE OF INSERVICE INSPECTION l
1, the undersigned, holding a vali commissionissued by the Nati nal B ard of B iter nd Pressure esset nspectors and the State or Province of Nf11/1 #X o 4 and employed by F Oe b4A hY F [ of C#b0e , b o 71 M have inspected the components described in this Owner's Repurt during the period 3*3 'Y b to d
- M 'i 7 and state that j
to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this l -' f Owner *: Report in accordance with the requirements of the ASME Code,Section XI.
Oy signing this certificate neither the Inspector nor his employer makes any warranry, expressed or implied, concerning the l examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer i
shall be lieble in any menner for any personst injury or property damage or a loss of any kind arising from or connected with this inspection
/
+- f(W r----i Inspect' ors Signature Commissions n w 9 cc - / 7 Y Nationsi Board, State. Province, and Endorsernents 0.te 3-/O ,, 9' f(
f I
I
FORM NIS 2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI page 3 9I
- 1. owner Northern States N...
Power Co.
55089 heet !
1717 Wakonade Dr. E, Welch, MN $ . cf._.
AdWm l
Unit !
- 2. Plant Prairie IslandName .
970 900 f, . 97 o 900 7. 970 900 ?
same Mepair ors'entretion P.O. No lob No., etc.
Address Type Code symbol stamp M4
- 3. Work Performed by Owner Name Authorization No. A/N Expiration Date M Ad dress
- 4. Identification of System . b # eu t O 4 f O W o !u A C m ro 19d Edition,
" ~~!
- 5. (e) Applicable Construction Code N/ _ Addenda; , Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19_
N
- 6. Identification of Components Repaired or Replaced and Replacement Components ASME Code Repaired, Stamped National Replaced, Year (Yes Manufacturer Board Other Name of Name of or Replacement or No)
-Gerret No. N o. Identification Built Component Manufacturer in cd<d FM b x Y6]A s b-15m' Al O N~/Oi MN bMacceed W%"K1 as~ s- T uc no I % -e a J
'UW2h v6 s- \ oc-a-5 F wt_1 d PRM bA& bkCC k !OO
- 7. Description of Work RCD /4CCh 4 f *)
8 L
l B. Tests Conducted: Hydrostatic 0 Pneumatic 0 Nominal Operating Pressure @
psi Test Temp. //o *F Other O Pressure cNod NOTE: Supplemental sheets in f orm of lists, sketches, or drawings may be used, provided (11 size is 8% In. x 11 i tion in items 1 through 6 on this report is included on each sheet, and {3) each sheet is numbered and the num recorded at the top of this form. ;
f (12/82) This Form (E00030) may be obtained from the Order Dept., ASME,345 E. 47th St.. New York, N.Y.10017
- =
$ggf" k Of FORM NIS 2 (Back)
- 9. Flemarks Applicable Manufacturer's Osta Reports to be attached CERTIFICATE OF COMPLIANCE ._
We certify that the statements rnade in the report are correct and this conforms to the rules of the
'+*A**"'*"'
ASME Code,Section Xl.
Type Code Symbol Stamp Certifica e f Authorization No. Expiration Date
/W .
b a >' Date 19 Signed l_Cwner or Owner's Designes, Title / & 8 l
]
CERTIFICATE OF INSERVICE INSPECTION )
I, the undersigned, holding a vali ommission issued by the Nati nal d of iler and Pressure Vess inspec an the State 1 e r 87e'O ^ 6I Ce / of or Province of b[MMMSO 4 and employed by Cifb b ecf.boaM have inspected the components described
/1* M ~ k 7 in this Owner's Report during the period
~9 b to and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI, By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner *: Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personalinjury or property damage or a loss of any kind arising from or connected with this in spection.
Commissions Inspector's Signature National Board, State Province, and Endorsements
- /
Date 19 l
l
7--
FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
- 1. owner Northern States Power Co. oete-- 3 9 97 Neme 1717 Wakonade Dr. E, Welch, MN 55089 hee JLog S
/7 Address unit /
- 2. Plant Prairie IslandN.me .
same lace Y- Orofw 94076o/
Flapelt Orgentastion P.O. No., Job No., etc.
Address Type Code Symbol Stamp Al A
- 3. Work Performed by__ Owner A/4
"*'"* Authorization No.
Expiration Date M
Addreas
- 4. Identification of System . kfmtCAI Uols O_o. b i -
- 6. (e) Applicable Construction Code / 19 ._ Edition, Addenda, Code Case (b) Applicable Edition of Section XI Utillzed for Repolts or Replacements 19
- 6. Identification of Components Repelred or Reptoced and Replacement Components ASME Code Rep aired, Stamped National Replaced, (Yes Board Other Year Name of Name of Manufacturer or Replacement orNo)
Serial No. N o. Identification Bellt Component Manufacturer w'
/3 C % .. A, . Ajm we -a4 /vr-ov?> uA km/
I l
NL l d 4ba bU
- 7. Description of Work e#4irL f L8 *M
- 8. Tests Conducted: Hydrostotle O eneum.iic 0 uominai ooer.ciasereisure t psi Test Temp. //O 'F l OtherO Pressure JVD0 NOTE: Supplemental sheets in form of lists, sketches, or drawings rnay tw used, provided (1) size i is 8%
tion in items 1 through 6 on this report is included on each sheet, and (J) each sheet is numbered and recorded et the top of this form.
i This Form (E00030) may be obtained from the Order Dept., ASME,345 E. 47th St.,New York, N.Y.
(12/82) l
\.
l J
l
&f57'lbofI?
FORM NIS.2 (Back)
- 9. Remarks Applicable Manufacturer's este Reports to be etteched t
CERTIFICATE OF COMPLIANCE ..
We certify that the statements made in the report are correct and this If 00 I I conforms to the rules of the ASME Code,Section XI. "* '**'*****"'
4 Type Code Symbol Stamp
' Certifica Authortration No. Expiration Date .
Signed M Owner or Owners Designee, Title /
. bb ate l
19 CERTIFICATE OF INSE AVICE INSPECTION 1, the undersigne holding a val commission issued by the Natio at Bo f8 er ressure Ves I in ctors the State or Provinc f I *'#18S M 4 and employed by /> "" 8e NA DI & of M*bbd a be d #1 have i ected the components described j b /b 7 '
in this Owner's Report durir g the period to and state that to the best of my knowledge end belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.
By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shell be liable in any menner for any personalinjury or property damage or a loss of any kind arising from or connected with this inspection.
~ W Commissions I
- I n.p _, s ... n....e e . t..n .. . . . o. .. .... ....t n. .. .n_ n o . r s. .n s: ,
~
Date tg l
i l
, l l
~.
l FORM NIS.2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS I As Required by the Provisions of the ASME Code Section XI
- 1. Owner Northern States Power Co. o,t. 3 9[
Name l 1717 Wakonade Dr. Er Welchr MN 550895 heet / 7 of /7 l
Address l
- 2. Plant Prairie Island . Unit !
Name Same Wo 7UNS Repe4r Organisetton P.O. No., Job No., etc.
Address
- 3. Wo'rk Performed tsy Owner Type Code Symbol Stamp M Nome Authorization No.
" MN Expiration Date
""~ M AJdress
- 4. Identification of System . bf m ALa k U6/u m ( bO ra f
~
- 5. (a) Applicable Construction Code ! 19 b 7 Edition, "
Addenda _- Code Case (b) Applicable Edition of Section XI Utiltred for Repairs or Reptocements 19 7
- 6. Identification of Components Repelred or Reptoced and Replacement Components ASME Code Repaired, Stamped National Other Year Replaced, (Yes Name of Nome of Manufacturer Board Built or Replacement or No)
Component Manufacturer Serial No. N o. Identification
$04 f f~
rd 0 hp*pif NQepje,,,J U l
Ip& A/S P ,g. uc. ;3g xjR i
- 7. Description of Work M!d CC f#,44.-
- 8. Tests Conducted: Hydrostatic @ Pneumatic Nominst Operating Pressure O
/(p psi Test Temp. 70 'F Other O Pre >>u
NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (11 size Is 8% in. x 11 in., (2) Informa.
tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded et the top of this f orm.
l (12/82) This Form (E00030) mov be obtained from the order Dept., ASME,345 E. 47th St.. New York, N.Y.10017
-_ - ____-______-______J
{
l . .
a l
/
l Sneer I 7 of I 7 \
I FORM NIS 2 (Beck) b
- c. Re,n.ru, P l p e-- kaL m lx banc nd leaIc 1
..oii hie uenutoo.,.re ost. ..,ss .o he .m.t .d i
'-- - - - - - - . ,* . . . I CERTIFICATE OF COMPLIANCE dCr M M conforms to the rules of the We certify that the statements made in the report are correct and thisrepair
' _t* or replacement ASME Code,Section XI.
Type Code Symbol stamp Certifica 3ef Authorization No.
NV Expiration Date N$
b# h 19 h Signed A -
Date ~ /
Owner of Owner's Designee, Title #
CERTIFICATE OF INSERVICE INSPECTION atBo f Boil r and Pressure Ves I in ectors and the State 0i & DE of 1, the undersigned, holding a validjommission issued by07the Nat loyed by dr ' No%
or Province of [ t M M FS o T 4 have inspected the components described l Ha r i fo.-Jmd e"8e n 4 Il ~ O 4 7 In this Owner's Report during the period
' 3 '9 b to . and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures d Owner's Report in accordance with the requirements of the ASME Code,Section XI.
By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implie examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his shall be liable in any manner for any personalinjury or property damage or a foss of any kind arising from or co!
Inspection.
~
Commissions National Board, State. Province, and Endor sements l - -
lan'p ector"t signature V/
~~
Date 19_
l i
I I
1 I
i . ., '
l NORTHERN STATES POWER
SUMMARY
REPORT 1
lNSERVICE INSPECTION PRAIRIE ISLAND UNIT 1,1997 l
i APPENDIX A INTERVAL 3 PERIOD 2 INSPECTIONS BY ISO 10 Pages i
l i
e ,
. Prairie Island Nuclear Generating Inservice inspection Report Log Northern" States Power Company 1717 Wakonada Drive Third Interval By Iso /Itse 414 Nicollet Mall Welch, M4 55089 Commercial Service Dater December 16, 1973 Minneapolis, MN $5401 ISO Item Report Number Method Results System Item Description Exam Date ASME Section XI Item Foreign Dwg 893C173 062-111 97-0003BL MT l NAD Turbine Spreader Spreader beam 09/12/97 Nureg 0612 NC ;
A HX 1-1397 Lift Fixture 97-0001 MT I NAD Rx Head Lift Fixture Rx Head 06/05/97 Nureg 0612 NC HX 1-1397 Lift Fixture 97-0002 VT1 IND Rx Head Lift Fixture Rx Head 06/05/97 Nureg 0612 NC Hissing roll pins HX 1-1397 Lift Fixture 97-0002R1 VT1 NAD Rx Head Lift Fixture Rx Head 10/20/97 Nureg 0612 NC Roli pins are left out for maintenance adjustment prior to each litt.
ISI- LA H- 2 97-0037 VT3 NAD CHARGING LINE 'B' SNUBBER 10/23/97 F-A C1 I ISI- IB H- 4 97-0139 VT3 NAD CHARGING LINE *B' LATERAL RESTPAINT 11/06/97 F-A C1 1
~iSI- IC H- 1 97-0126 VT3 NAD CHARGING LINE 'B' ANCHOR 11/04/97 F-A C1 I ISI- IC W- 1 97-0129 PT NAD CHARGING LINE 'B' PIFE - TEE 11/05/97 8 9. 21 ISI- IF W- S 97-0049 iPT +
NAD CHARGING LINE 'B' 45e ELBOW - PIPE 10/24/97 f B 9. 21 97-0050 t FT i NAD R TV "~~ W6 '
CHARGING LINE 'B' PIPE - 45e ELBOW 10/24/97 ' B 9. 21 l
ACCUH. CISCHARGE 'A' SPRING 10/27/97 F-A & B10. 10
! Follow-up__e.xam ACCUM. DISCHAAGE 'A' 10/29/97 I F-A 6 B10. 10 lSFPING f j Follow-up exam, concrete i al(ig , load setting
. . . . . . _ _ . ._ _ _ _ _ . . _ g ACCUM. DISCLARGE 'A' i
SPRING 11/06/97 F-A & B10. 10 1s!- 2 ; W- 5 97-0105 NAD ACCUM. DISCHARGE 'A' 11/25/97 B 9, 11 l ELBOW-VALVE
_l ".19 t ._.OEA_,1f 97 0,7 4,__ , _ _
ACCUM. DIS:HARGE 'A' l ELDOW - VALVE 11/25/97 8 9. 11 "19 L OEA,199107,4 _
ACCUM. DI# CHARGE 'A' ! elbow-VALVE t11/25/97 f B 9, 11
. ~. _ . _ , . _ _ _ _ _ _ . . _ . - _ ..
_._ _. 37.".I9L 9EA._1.I9'E.'. 4 a __ __.
RHR 140P 'A' ' VALVE BOLTING
. {10/21/97 ,B7 70
' i l 3B r H. ( 197-0013 (A) ! VT3 'NAD ISI-RHR LOCP 'A' RUPTURE RESTRAINT 10/21/97 F-A C1 I l . . . - . . - .- _ . . .
\ . --. . . . . . .. .--_-.- - . .
kHP LOCf *A' SIESMIC PESTRAINT j10/21/97 F-A C1 .
ISI- 3B H- 9 : 91-0007 V'3 IND BhR UJCP 'A' ' RX l10/01/97 i F-A 01 !
l
' < No lead on rod i H- e VT3 NA0 1$5- 3B }97-000iP1 PHR 140P 'A' > ROD {10/30/97 F-A C1 1
___i____ _ . _ _ . . .E *9 f k'd _ _ ._
Page 1 03/10/D8
e ,
I Prairie Island Nuclear Generating Inservice Inspection Report Log Northern States Power Company 1717 wakonado Drive Third Interval By Iso / Item 414 Nicollet Mall Welch, Mh 55089 Comearcial Service Dates December 16, 1973 Minneapolis, MN 55401 ISO Item Report Number Method Results system item Description tram Date ASME Section XI Item ISI- 3B W- 5 97-0127 PT 'NAD l
RHR LOOP 'A' 45s ELBOW - PIPE 11/04/97 B 9. 11 Limited exceeds 90%
W- 5 {97-0134 UT45 ,NAD ISI. 3B RHR LOOP 'A' 45e ELBOW - PIPE 11/04/97 8 9. 11
!$1- 3C H- 1 97-0014 (A) VT3 ;NAD P.HR LOOP 'A' KANGER 10/21/97 T-A C1 I 6 l
ISI- 3C H- 8 97-0016 (A) VT3 NAD RNR LOOP 'A' ROD MANGER 10/21/97 r-A & B10. 10 ;
i ISI- 5A H- 4 97-0137BL VT3 NAD SPRAY TO PPESSURIEER HYDR SNUBBER / CLAMP 11/13/97 F-A C1 I l j W-10 97-0156 PT ! NAD l ISI- LA REDUCING TEE - PIPE 11/10/97 8 9, 21 I SPRAY TO PRESSURIZER l
ISI- 5A W-12 97-0093 PT NAD SPRAY TO PRES $URIZER ELBOW - PIPE 10/28/97 B 9. 21 ISI- 58 H- 6 97-0179 (A) VT3 NAD SPRAY TO PRESSURIZER DOUBLE SNUBBER /CIMP 11/25/97 F-A C1 I t
{
'iSI- 6 B- 1 97-0106 VT1 {NAD PTD PETUPN 'A' BOLTS FLANGE 10/30/97 B 7. 50 i 1
' I' s'i - 6 W- 4 97-0115 l PT ! IND PTD RETURN 'A' PIPE - FLANGE 11/01/97 B 9, 21 Linear indications 4 NAD
.ISI-_ , _ _6 W- 4 l97-0115R1 PT PTD RETURN 'A' PIPE - FIMGE 111/21/97 8 9. 21 I Engineer}ng g eluation
'W- 6 ;97-0105 PT NAD ISI- 6 PTD RETURN 'A' PIPE - ELBOW 10/30/97 l B 9. 21
! I N'!- T ~~ W-22 l97-0107 i PT NAD HTD TAKE OFF ' A' HOT PIPE - ELBOW !10/30/97 . B 9, 21 l !
CBN TON CPOSSOVER) A DBLE SPRING / BENT BAR 10/30/97 F-A 01 I [
H- 2 97-0103R1 (A) 3 IND 151- 10 i IPN (ON CROSSOVER) A T-A C1 I
{DBLE SPRING / BENT BAR l11/06/97 FI 91-0103R2 (A) ~ tdab' 5S5' l'O-C+N 10N CROSSOVERl A iDBLE SPRING / BENT BAR !11/07/97 g F-A C1 I i
E ineering evalqatio3 _ _ __,
FEAL INJ LOOP 'A' l10/30/97 T-A C1 1 fRODCLAMP
-. . .. . - - . . . _ . . - ~ _ . . _ . . . - . -
RC FUMP 11 UPPER SEAL HOUSING ;10/29/97 B7 60
_.1___ . C>eformed socket Lead NAD ISI- 14. . . . . . . . _ _ . :B- 3 97-0102R1 VT1
$0 PUMP 11 IUPPER SEAL HOUSING '11/05/97 B7 60 P-fl yed bolt _ _ _ . _ __.__
Ja;- 14 B- 4 9'-F101 VT1 IN:'
l
- 5 0 I"?MP 11 , LOWER SEAL HOUSING '10/19/97 8' 60
. ..._, - . _ _ .__ .. Miner dents.a :Nrens RO PtHP 11 . LCVER SEAL HO"SINO 11/05/97 B7 60 1
. . EE9 f Bte r Lt.g evalcat ten . ..__
97-0059. . _ . VT3 NAD I$1 14. . . . . .H- 1 jTIE BACK P 1 10/25/97 F-A 6 B10, 20 kr PtHP 11 Page 2 03/10/0g
1 Prairie Island Nuclear Generating Inservice Inspection Report Log Northern States Power Company 1717 wakonede Drive Third Interval By Iso / Item 414 Nicollet Hall welch, >td $5009 Commercial Service Dates December 16, 1973 Minneapolis, MN 55401 Iso Item Report Number Method Results Systese Item Description Exam Date ASME Section XI Item 131- 14 H- 1A 97-0060 VT3 !NAD RC PLEP 11 TIE BACK BOLT 9 1 10/25/97 F-A C1 I ISI- 14 H- 1B 97-0061 VT3 vNAD RC PUMP 11 TIE BACK PIN 9 1 10/25/97 F-A C1 I i ICI- 14 H- 4 97-0062 VT3 NAD RC PUMP 11 PAD 1 10/25/97 F-A C1 I ISI- 14 H- 5 97-0066 (A) VT3 'NAD RC PUMP 11 FAD 2 10/25/97 F-A C1 I j ISI- 14 H- 7 97-0063 VT3 lNAD RC PUMP 11 CONNECTION 9 1 10/25/97 F-A C1 I ISI- 14 H- 7A 97-0064 VT3 NAD RC PLHP 11 COLUMN TOP & PIN 9 1 10/25/97 F-A C1 I ISI- 14 h- 6A 97-0065 (A) VT3 NAD RC PUMP 11 COLUMN TOP & PIN 9 2 10/25/97 F-A C1 1 ISI- 14 H-10 97-0021 VT3 NAD RC PUMP 11 BASE 9 1 10/21/97 F-A C1 I I,
ISI- 14 H-10A 97-0022 VT3 jNAD RC PUMP 11 COLUMN DOT & PIN 9 1 10/21/97 F-A Cl I ;
ISI- 17 W- 7 97-0160 PT ; NAD 12" ACCUMULATOR DSCH RED. TEE - VALVE 11/25/97 89, 11 IN 97-19, OEA 1997074
'IS E 17 W- 7 97-0189 UT45 NAD 12" ACCUMULATOR DSCH RED. TEE - VALVE 11/25/97 B 9. 11 IN 97-19, OEA1997074,
- Limited, Execeds 90%
W- 7 97-0191 (A) 4 UT60 , NAD ISI- 17 12" ACCtHU1ATOR DSCH RED. TEE - VALVE 11/25/97 fD9.11 i IN 97-19_,O_EA. 194707_4 _
ISI- 19B B- 1 97-0012 [ VT1 .NAD 10/21/97 0" RHR TAKE OFF 'B' VALVE BOLTING 1
lB7 70 ISI- 19a IW-10 97-0132 : PT NAD 8" RHR TAKE OFF 'B' !ELBCW - PIPE 11/05/97 8 9. 11
't 5
~
'{ S f.~1'ijB-^'" w lo 710133 AD 8" RHR TAKE OFF l elbow-PIPE 11/05/97 11
'B' f B 9. - . - - . _ . . . .
3" RTD PETURN LOOP B {RUP'TPESTRAINT 10/27/97 ; E-A C1 I l
.97-0069 l 'v T 3 NAD ISI- 26 f' H - 1 i 2" CVCS LETICWN 'B' ! HYDR SNUBBER !10/20/97 F-A C1 1 i !
_. _ _ - _._ _ .~ __. _ . _ .
2" CVCS LET[ ANN 'B' $PRING MANGER / CLAMP 10/28/97 t F-A C1 i
! ! i ISI- 26 H- 8 ,47-0091 (A) ' VT3 NAD 1
2" CYCS LETIOWN *B' : HYDR SNUBBER / CLAMP '1C/28/97 F-A Cl I VALVI - FIPE 41/01/9? B a 2 j 2" CVCS LETM WH 'B' ISI- 2?A B- 2 97-0003 V*1 NAD SEAL INJ 1DOF 'B' EOLTS 10/27/97 B' O
! CEAL INJ LOOP 'B' FIFE - FLANGE 10/27/9' B 9, 21 i l
Page j
! 01/10/98
_ _ _ _ - _ _ _ _ - _ - _ _ _ _ ________ U
1 1 , ,
Prairie Island Nuclear Generating Inservice Inspection Report 1,og Northern States Power Companyi 1717 Wakonada Drive Third Interval By Iso / Item 414 Nicollet Mall Welch, M4 55089 Cosumercial Service Date: December 16, 1973 Minneapolis, MN 55401 ISO Item Report Number Method Results System Item Description Esta Date ASME Section XI Item ISI- 27B H- 2 97-0147 VT3 lNAD EEAL INJ IDOP 'B' ANCHOR 11/07/97 F-A C1 I i i
I ISI- 30A V- 1 97-0192 VT3 i NAD PEACTOR VESSEL SIS A VALVE INT SURFACES 10/26/97 B12, 50 ISI- 31 H- 2 97-0121 (A) VT3 NAD PRESSURIZER PELIEF RUPTUPE RESTPAINT 11/03/97 F-A C1 I ISI- 34 8- 1 97-0149 UTO 'NAD RC PUMP 12 PUMP FIANGE BOLTS 11/07/97 8 6.180 ISI- 34 B- 3 97-0145 VT1 jNAD RC PUMP 12 LOWER SEAL HOUSING 11/07/97 B7 60 ISI- 34 B- 4 97-0146 VT1 NAD RC PUMP 12 UPPER SEAL HOUSING 11/07/97 B7 60 ISI- 34 H- 1 97-0067 (A) VT3 NAD RC PUMP 12 TIE BACM 41 10/25/97 r-A 6 B10. 20 ISI- 34 H- 3 97-0068 VT3 NAD PC PUMP 12 TIE BACK 9 3 10/25/97 F-A a B10. 20 l
E i- 34 H- 3A 97-0069 VT3 iNAD PC PUMP 12 TIE BACK BOLT 93 10/25/97 F-A C1 I I ISI- 34 H- 3B 97-0070 ' VT3 ; NAD RC PUMP 12 TIE BACK PIN 93 10/25/97 F-A C1 1
~~-
Hg']g H- 6 9 97-0071 VT3 r NAD RC PUMP 12 FAD 3 10/25/97 T-A C1 I
- .. - ~ . - - . _ _._
RC PtHP 12 l COLUMN TOP & PIN 9 2 10/25/97 F-A C1 I ,
j Support in contact with pumpj in3 BC PUHF 12 ICOLUMN TCP & PIN 9 "' f11/05/97 l r-A C1 I
! Engineering evaluation ISI- 34 'H- 9 l 97-0072 VT3 . NAD RC PUMP 12 5
CONNECTION 9 3 I10/25/97 F-A C1 !
! l RC PUMP 12 COLUMN TOP & PIN 9 3 10/25/97 lr-AC1I
- i RC PtNP 12 jBAE93 Il0/25/97 T-A C1 1 I
. -.----...--.4 RC PUMP 12 lCOLUMNBOT6 FIN 9 3 10/25/97 F-A C1 I
.. . . _ ~ . . . .., . - -
RC PUMP 12 FLYWHEEL !. KEYWAYBCRE 6 l10/30/97 TS 4.2-1
- - . . - - - - - - + s-- - . ~ . - - . ~ ~ - - . - ~~
.- e- s-- . ~ ~ - ~ ~ -
-. . . . ~ - - u -. ,
RC FUMP 12 FLYWHEEL :FEYWAY s BORE 10/30/97 TS 4.2-1 R" PUMF 12 FLYWHEEL ' B0t Y 10/30/97 73 4.2-1
- . . _ . .-.- . . _ - - - . - - ~ - _ . . - . -
aC PUMP 12 FLYNNEEL PE&lFHEPt 10/30/9' T3 4.2-1
-~'NO
~~ '
ggg. j7
[g',~y, T d ~ ~ ~'~- U-ch o~ -- ' ~ ~g; ~
REACTOR VEMEL :NU"$ ,11/07/91 8 6. 10
.. , _ Limi t et ' M ._
Page a 03/10/0s
l s ,
I I Prairie Island Nuclear Generating Inservice Inspection Report Log Northern States Power Company 1717 wak.onada Drive Third Interval By 1so/ Item 414 Nicollet Mall welch, bei 55089 Commercial service Date: December 16, 1973 Minneapolis, MN 55401 ISO Itse Report Number Method Results System item Description Exam Date ASHE Section XI Item ISI- 37 R.V. STUDS 97-0154 MT NAD REACTOR VESSEL STULS 11/10/97 B 6. 30
- s. J-.
131- 37 R.V. STUD 3 97-0155 ! UTO iNAD I
RE. ACTOR VESSEL STUDS 11/10/97 i B 6. 30 R.V. WSHRS 97-0151 VT1 'NAD
~'I'S5 3 7 REACTOR VESSEL WASHERS 11/07/97 B 6. 50 MAPHON CIAMP 97-0170 VT1 NAD ISI- 39 P.V. CONOSCAL BLTING MARHON CIAMP 11/18/97 B1 10 W- 3 97-0144 UTO NAD ISI- 41 PRESSURIZER BOTTOM HEAD / SHELL 11/06/97 B 2. 11 Limited, Exceeds 90%
W- 3 97-0143 UT45 NAD IS!- 41 BOTTOM HEAD / SHELL 11/06/97 B 2, 11 PRESSURIZER Limited, Exceeds 90%
W- 3 97-0142 UT60 NAD ISI- 41 BOTTOM HEAD / SHELL 11/06/97 F 3, 11 PRESSURIZER Limited, Exceeds 90%
W- 5 97-0096 UTO NAD ISI- 41
- PESGURIZER TOP HEAD / SHELL 10/29/97 B 2. 11 Limitedn Exceeds 904 97-0099 UT45 NAD IS!- 41 W- 5 l FE ES3'.'R I Z ER TOP HEAD / SHELL 10/29/97 B 2. 11 Limited, Exceeds 904
. - _ +
W- 5 97-0100 UT60 jNAD
- - - .ISI- 41 FRESSUP!ZEk TOP HEAD / SHELL 10/29/97 B 2. 11 Limited, Exceeds 90%
97-0044 (A) ! UT60 : NAD ISI- 43A ! W- A 10/23/97 B 2, 40 STEAM GENEPATOR 811 lTUBESHEET/ HEAD I
... . .-...._.__ . , _ _,_ _4.._ _ ._ _ .~ _.___ - _._, _ _
NAD ISI- 43A W- F 97-0077 (A) UT60 STEAM GENEPATOR #11 , TRANSITION - SHELL 10/25/97 C 1. 10 l j i
-.._.__.._________....A .__. ._-_ .
'NAD j97-0076 (A)
- W- F UTC ISI- 43A STEAM GENERATOR #11 TPANSITION - SHELL 10/25/97 . C 1. 10 UT60 NAD ISI- 43A
- W- H h7-0081 (A)
STEAM GENERATOR til TOP HEAD - SHELL 10/27/97 C 1. 20 C 1. 20 STEAM GENERATOR 411 lTOPHEAD-SHELL l10/27/97 !
UTO NAD ISI- 43A lW- H t97-0079 (A)
STIAM GENERATOR 511 TCF HEAD = SHELL 10/27/97 C 1 20
_4_--_..__._.-- ..__.A... ,
IS!- 43B . _ . . - . _ . _ ~ . . _ ,N- 1 IN-IR ' 97-0092 MT~ _ - . _ . _ . . . . _ _ _ _ . . .NAD ..._ l FTEAM GENERATOR 612 t FEEDWATER NOZZLE f10/29/97 NO IN 93-20 i VT3 NAD 131 43B jN- 1 RING TEE j97-0094 STEM GENERATcR si. FW BING TEE / SUPPORTS l 10/ 28 / 97 NC IN 93-20 7
- W- A 0164. . . _ - _ _ _ UTO NAO
.-IS!- 43B. _ - _ - . _ _ . . _ _ _ ~
STEAM GENERATOR #12 : TUBE SHEET / HEAD 11/15/97 B 2. 40 4 .
. . . .. ___}iritet _E n.eeds a
- . _ _ . _ _ . . .97-0165 UT45 NAD 101- 438 <W-A-_
CTEAM GENERATOA 8;2 TCPE 5HEET / hT.AD ' 1/17 / F B- 43
. Laited, .E_xceeds. $4 97-0171 UTt? N;r 151- 438 ..W- A TTEAM 2 NERATOR 812 TUSE SWEET / HEAT ' ! /19 / P B2 42
._ L W I't.. Exceeds p @ .
97-0161 UT NAD 101- 43B W- S STFAM 5t hERATvR s12 TCPE3HEET - SFELL '11/19/P C. 30 Pap 5 03/10/D0
1 f Prairie Island Nuclear Generating Inservice Inspection Report Log Northern States Power Company 1717 Wakonada Drive Third Interval By Iso / Item 414 Nicollet Mall welch, ve4 55089 Commercial Service Dates December 16, 1973 Minneapolis, MN 55401
(
ISO Item Report Number Method Resulta l item Description Exam Date ASME Section XI Item j Gystem
! I3I- 43B W- B 97-0162 UT45 ' NAD l STEAM GENERATOR #12 TUBESHEET - SHELL 11/19/97 C 1. 30 I Limited, Exceeds 90%
ISI- 438 W- B '97-0163 l UT60 ,NAD STEAM GENERATOR #12 TUBESHEET - SHELL 11/19/97 C 1, 30 ;
Limited, Exceeds 90% !
ISI- 43B W- F VT 97-0095 VT1 l NAD STEAM GENERATOR #12 TRANS WELD INT VT 10/28/97 NC IN 93-20 ISI- 43C p- 9 97-0096 VT3 - lNAD STEAM GENERATOR #11 TOP SUPPOFT GIRDER 10/28/97 F-A C1 I l l
ISI- 43C H-10 97-0027 VT3 lNAD STEAM GENERATOR all FIXTURE 10/21/97 F-A C1 I j ISI- 43C H-11 97-0026 VT3 lNAD STEAM GENERATOR til FIXTURE 10/21/97 F-A C1 I i i
H-12 97-0025 VT3 NAD ISI- 43C STEAM GENERATOR #11 FIXTURE 10/21/97 F-A C1 I ISI- 43C H-13 47-0163 VT3 NAD STEAM GENERATCP #11 FAD 11/25/97 F-A C1 I l
H-16 97-0164 VT3 ' NAD ISI- 43C STEAM GENERATOR #11 FAD 11/25/97 F-A C1 I H-17 97-0178 : IND ISI- 43C lVT3 STEAM GENEPATOR d11 IB UNFER BLOCK 11/25/97 F-A C1 I l Lack of thread engagement _
97-0176R1 ^ VT3 NAD ISI- 43C jH-17 STEAM GENERATCR #11 lBUMFERBLOCK 11/26/97 F-A C1 I I Engineering evaluation ISI- 43 H-20 97-0020 i VT3 NAD STEAM GENERATOR #11 IBUMFER BLOCK 10/21/97 F-A C1 I J l
NAD
- S1- 43C H-21 l97-0015 lVT3 STEAM GENERATCR all TGF CONNECTION 91 11/10/97 ' F-A C1 I STEAM GENERATOR #11 CCLLHN TOP & PIN 9 1 11/19/97 F-A C1 I
.H-219 VT3 .NAD ISI- 43C %-0023 STEAM GENEPATOR #11 ICOLUMN BOT & FIN 9 1 i10/21/97 F-A CI I i !
VT3 IND J ISI- 43C H-24 [97-0016 '
CTEAM GENERATOR 411 TCP CONNECTION 94 ! 10/21/97 , F-A C1 1
! Bo.it_ net _flysh ytth plate _ , _ .
97-0018R1 VT3 NAD ,
ISI- 43C H-24 STFJ44 GENERATOR #11 : TOP CONNECTION 9 4 :11/04/97
- F-A C1 I '
_ _ ~ - - . _ , - _ . . . _ . _ . _ . .En neering evaluat1on _ , __
. - . - _ ~ . . . _ . . -
COLUMN TCP & FIN 9 4 ;10/21/97 ' F-A C1 1 STEAM GENERATOR #11
_ - . .. __ . _ _ _ _ . ._- . . _ . _ _ _ - . _ ______. _ . . . _ . _ . _ _ _ _ _ _ f COL"MN D]T & FIN 9 4 ,11/25/97 F-A C1 I STr>J4 GENERATOR til
~ - - - - - - - - - . -- . _
STEN 4 GENERATOR s '. .BAfE d ' 10/21/97 T-A Cl I l
~
9'-0152 VT3 *c IS - 4N H529 i
STEAM CENERATOR 411 BAJE 9 4 11/25/97 F-A C1 I ISI- 44~
H- 1h Y -013i ~ VT3 NA2 REGEN HEAT FXCliANaER : FLWTAND 11 26/97 i'-A 01 '
_ . ~ _
Pa9e 6 01/10/08
e .
Prairie Island Nuclear Generating Inservsco Inspection Report Log Northern States Power Company 1717 wakonade Drive Third Interval By Iso / Item 414 Nicollet Mall welch, MN 55089 Commercial Service Date: December 16, 1973 Minneapolis, M4 55401 Iso Item Report Number Method Results I system Item Description Exam Date ASME Section XI Item l ISI- 46 W- 1 97-0116 PT j NAD RCS CRAINDOWN PIPE - NCZZLE 11/01/97 B 9. 31 I
. - . . _ISI- 46 W- 1 97-0148 UT45 i NAD RC3 D9AINDOWN PIPE - NOZZLE 11/15/97 8 9. 31
^[35-40 VESSEL INTR 97-0122 VT3 NAD PEACTOR VESSEL VT INTL SURFACES 11/03/97 B13. 10 This report will not be credited as 2nd period exam.
ISI- 49 W- 6 97-0123 MT NAD R.V. CLOSURE HEAD HEAD - FIANGE 11/03/97 B 1. 40 ISI- 4 9 W- 6 97-0172 UTO NAD R.V. CLOSURE HEAD HEAD - FIANGE 11/12/97 B 1. 4 0 ,
Limited, Lass than 904 1 ISI- 49 W- 6 97-0173 UT45 NAD R.V. CLOSURE HEAD HEAD - FLANGE 11/11/97 B 1. 4 0 Limited, Less than 904 ISI- 49 W- 6 97-0175 UT60 NAD R.V. CLOSURE HEAD HEAD - FLANGE 11/10/97 8 1, 40 Limited, Less than 90%
ICI- 49A W-04 97-0124 PT NAD RV Top Head CRD-04 Housing Weld 11/03/97 B14. 10
. - _ _ . . . . . . - . _ _ - . +
131- 49A W-26 97-0125 PT !NAD PV Top Head CRD-26 Housing Weld 11/03/97 B14. 10 )
I
. . . . . _ . _ . . . . . _ _ . _ . a ISI- 51A 97-0087 IA) t MT ! NAD
\' H- 5 t MAIN STf.AH 'A' BEAR'G BPAK ASSY O) 10/25/97 i F-A 6 C 3. 20 Limitede Less than 904
- - . . _ _ . . . . . _ - _ . . _ _ . . __. .e ISI- 51A H- 6 97-0086 (Al MT iNAD MAIN STEAN 'A' BEAR'C BRAK ASSY Op 10/25/97 F-A & C 3. 20 i
Limited, Less than 90%
ISI- $1B H- 3 i97-0114 ' MT : NAD 10/31/97 F-A C1 Il !
MAIN STEAM 'A' SPRING MANGER ICI- SIB 'W- 6 LS D 23 l97-0032 ' MT I
NAD MAIN UTEAM 'A' i
,45e ELBOW - FIFE 10/22/97 C 5. 50 f
'1 i ISI- 51B W- 6 LS D 2U !97-0097 14 45 GEO MAIN STEAM 'A' ;454 ELBOW - FIPE l10/29/97 . C 5. 50 ISI. SIC ;97-0029 ,VT3 : NAD l H- 1 MAIN STEAM 'A' iSUPICHT BRAF ASSY !10/22/97 l F-A s C 3. 20
. Cog Cast,N-49.1 _ _ _ ___,,_ , . _ _
i MAIN GTEAM 'A' I' SUFFORT BRAK ASSY {10/23/97 F-A & C 3. 20 i Limited,, Le s s t han_ _90% _ _ , _ _ .
131- 51C .H- 3 l97-0029 (Al , VT3 NAD MAIN STLAM 'A' {10/22/97 F-A C1 II
!CONST SUFPORT MAIN STEAM 'A' i PI PE - FIANGE ,10/22/97 C 5. 60 181- 51C W-13 LS U 9'-0034 MT NAD MIN CTEAM ' A' FIFE - CAP 10/22/97 C5 52 9' bOh
~
W-if Lf ' NAr
'I S I 'M ' ' 4
! MAIN OTEAM 'A' -fire - CAF 10/22/97 C' ~
'95b1N 1 ' iAD
~
f 101 ';c 'W-I5'LS ' d*T '
l C 5. 5:
r MIN OTLN4 'A' PITE - CAF 11/26/9'
' ~
ISI- 52 'H-^ 1 I b 0330 $"l ' *.ED FEE:wATEP L;X'? 'A' Sif'?C FL5TRAINT 10/22/9' F-A & -" 7. 20 Page 7 03/10/09
i l
e .
Prairie Island Nuclear Generating Inservice Inspection Report Log Northern States Power Company 1717 wakonade Drive Third Interval By Iso / Item 414 Nicollet Mall welch, MN 55089 Comanercial Service Dates December 16, 1973 Minneapolis, MN 55401 ISO Item Report Number Method Results System Item Description Eram Date ASME Section XI Item ISI- 52 H- 1 97-0078 VT3 'IND FEEDWATER LOOP 'A' SIESHIC RESTRAINT 10/27/97 F-A & C 3, 20 Loose nut and gap ISI- 52 H- 1 91-0078R1 VT3 NAD FEEDWATER LOOP ' A' SIESMIC RESTRAINT 11/06/97 F-A & C 3. 20 ;
Rework and Engineering I evaluation l ISI- 52 H- 5 97-0174 MT lIND FEEDWATER LOOP 'A' RESTRAINT 11/20/97 F-A & C 3. 20 j Linear indications ISI- 52 H- 5 97-0169 VT3 lNAD FEEDWATER LOOP 'A' RESTRAINT 11/20/97 F-A & C 3. 20 l t
ISI- 52 H- 5 97-0174R1 MT NAD FEEDWATER LOOP 'A' RESTRAINT 11/25/97 F-A & C 3. 20 Engineering evaluation ISI- 52 H- 6 97-0166 MT NAD FEEDWATER LOOP 'A' ANCHOR ELBOW 11/20/97 F-A & C 3. 20 ISI- 52 H- 6 97-0167 VT3 NAD FEEDWATER LOOP 'A' ANCHOR ELBOW 11/20/97 F-A & C 3, 20 ISI- 52 W- 2 97-0031 MT NAD FEEDWATER LOOP 'A' PIPE - ELBOW 10/22/97 C 5. 51 & HEI.B 151- 52 W- 2 97-0051 UT45 iNAD FEEDWATER LOOP 'A' PIPE - ELBOW 10/24/97 C 5, 51 & HELB !
- - - .Is!- 52 ~W-12 97-0168 MT ! NAD FEF.DWATER LOOP 'A' ELBOW - PIPE 11/20/97 C 5. 51 ISI- 52 W-12 47-0176 UT45 , DAD ~~
FEEDWATER LOOP 'A' IELDOW - PIPE 11/21/97 C 5. 51
.. _ - _ _ _ _ _ +
FEEDWATER LOOP 'A' 11/08/97 C 5. 51
{ REDUCER-NOZZLE FEF.DWATER LOCF *A' REDUCER - NOZZLE 11/08/97 C 5. 51 PHR SUCTION PUMP 'A' ANCHOP (STRUT) 11/06/97 lF-AC1II RHR 59CTION PtHF 'A' FEDUCER - SED. TEE 11/05/97
{lC5.10 i
RHR SUCTION FUMP 'A' ; REDUCER - RED. TEE !11/05/97 ' C 5. 10 i
. ~ . - - - - . _ - _- _ _ - - _ _ . ._
RHR SUCTION PUMP 'A' !REDUCfNG TEE - PIFE i11/05/97 C 5. 10 i ! l
. . . . ~ _ . _ . . . _ _ - _ _ _ . ;
RHR SUCTION PtHP ' A' l REDUCING TEE - FIFE 11/05/97 C 5. 10 131- 660 jH- 1 97-0141 VT3 NAD MAINSTF1W 'b' BE.AE'G BRAK ASSY '10/20/97 F-A & C 3, 20
~
131 eC 'h-~i W-6239 ~M+ Ar j MAINJTEAM 'B' ;BEAA*G 9AAK ASSY 10/23/97 F-A 6 C 3. 20
...L.imited, Less than 92%
f ISt. t8; W- 3 . . _ - - 0011_- _ MT st MAINSTEAM 'B' FIFL - ELD 0% ,10/21/97 C 5. 51
~~ ' - '
1g!- cae W- 3 ? 9710017 ^'UT45' 3E0 MAINCTLAM *B' iFIFE - ELB0W ;10/21/97 C5 51
. - _~
Page e 03/10/00
- - -- -~ '- '-
- - ~ - - - - - ~ - ' - - - - - ~ - - ~ --'-
i 0
4 e l
l l
l Prairie Island Nuclear Generating Inservice Inspection Report Log Northern States Power Company 1717 wakonada Drive Third Interval By Iso / Item 414 Nicollet Mall welch, De8 55089 Commercial Service Datet December 16, 1973 Minneapolis, MN 55401 ISO Item Report Number Method Results System Item Description Exam Date ASME Section XI Item ISI- 69C iW-11 97-0128 M* !NAD MAINCTEAM 'B' PIFE.- FLANGE NOZZLE 11/05/97 C 5. 60 l ISI- 68C W-12 LS U 97-0187 (A) MT '. NAD MAIN 3 TEAM 'B' PIPE - CAP 11/26/97 C 5. 50 f l
151- 68C W-18 LS U 97-0008 MT IND MAIN 3 TEAM 'B' PIPE - CAP 10/21/97 C 5. 50 l Linear indications ISI- 68C W-18 LS U 97-0036 UT45 NAD MAINSTEAM 'B' PIPE - CAP 10/22/97 C 5. 50 ISI- 68C W-18 LS U 97-0008R1 MT NAD MAINSTEAM 'B' PIPE - CAP 11/03/97 C 5. 50 Repair ISI- 69 W-25 IN 93-20 97-0052 UT45 NAD TEEDWATER LOOP "B' PEDUCER - NO11LE 10/24/97 NC IN 93-20 ISI- 69 W-25 IN 93-20 97-0053 UT60 GEO FEEDWATER LOOP 'B' REDUCER - N0ZZLE 10/24/97 NC IN 93-20 l ISI- 89A W-21 97-0047 PT NAD RHR PUMP "A" DISCH VALVE - PIPE 10/24/97 C 5. 11 ISI- 89A W-21 97-0056 UT45 jNAD RHR PUMP "A" DISCH VALVE - FIPE 10/25/97 C 5. 11 1 4 f
ISI- 89A jW-22 97-0048 PT jNAD RHR PUMP "A" DISCH fPIFE-ELBOW 10/24/97 C 5. 11 ! l l l ISI- 89A iW-22 j97-0057 UT45 i NAD PHR PUMP "A" DISCH I
PIFE - ELBOW 10/25/97 C 5. 11 ;
i H- 7 ' 97-0045 VT3 ; NAD ISI- 998 RNR PUMr 'B' DISCH lRIGICHANGER/CI.P,MP 10/24/97 F-A CI II t
t iW-29 PT l NAD ISI- 898 l97-0046 RHR PUMP 'B' DISCH jrIPE - 55e ELBOW Il0/24/91 C 5. 11 g I
RHR PUMP 'B' DISCH { PIPE-55eELBOW 10/25/97 j C 5. 11
! I i H- 1 " VT 3 IND I ISI- 938 l97-0005 ' .
FHR HEAT EXCH 12 !SUFPOPT l10/17/97 T-A & C 3. 10 EcJe_t e _sga l l _i g _ ___,,__ , ,_,
RHR MEAT EXCH 12 )SUFFOPT ;11/24/97 i F-A & C 3. 10 I Linear indication NAD I ISI- 938 H+ 1 ! 97-0005R1 i VT 3 RHR HEAT EXCH 12 'SUFPORT '11/04/97 T-A 6 C 3. 10 ISI. 939 iH- 1 97-0177R1 P ' ~~ N>b Ri4R HEAT EXCH 12 lSUFFORT ;12/01/97 {F-A6C3.10
_ _ _ _ . , _ _ _ _ _ . . _ ! ' R' Fair ISI- 93B .W- 1 ,97-0004 ! U*45 NAD ftHR HEAT EXCH 12 i HEAD - SHELL I 10/17/97 C 1. 23 L W1t % less tha.n 90%
NA:
l -. . - _ .99A. _ . .
ISt- 'W- 2 97-005$ PT FI 11 MOCliAME REC'CER - FIPE I?!!S ' T Ci 2 ITI- MA' W- 2' 9 S0112 U*l ' NAr 11 I:ISCKARSE GEOUCER - PIPE 10/30/97 C' 21 f -I t .
t 151- 96A , .W- ..2 97-G1!9 L'* s 0 .. GEO SI 11 P10:CdAASE RED"CER - TIPE 10'30/97 C 5. 21 Page p 03/10/98
e ,
Prairie Island Nuclear Generating Inservice Inspection Report Log Northern States Power Company j 1717 Wakonada Drive Third Interval By Iso / Item 414 Nicollet Mall
' Welch, MN 55089 Cossnercial Service Date: December 16, 1973 Minneapolis, MN 55401 i
180 Item Report Number Method Results System Item Description Exam Date ASME Section XI Item ISI- 99B H- 1 97-0117 VT3 iNAD
' I SI 11 DISCHARGE .
BOX SUPPORT 11/01/97 , F-A C1 II ISI* 9BB W-11 97-0110 PT -NAD SI 11 DISCHARGE ELBOW - P1PE 11/01/97 C 5. 21 l 97-0120 UT45 NAD 151- 908 W-11 SI 11 DISCHARGE ELBOW - PIPE 11/01/97 C 5. 21 H- 3 97-0006 VT3 ; NAD
)
j ISI- 99A i
SI 12 DISCHARGE RCD / CLAMP 10/20/97 F-A C1 II j W-19 97-0042 PT NAD ISI- 99A SI 12 DISCHAPGE FLANGE - PIPE 10/21/97 C 5. 21 l W-16 97-0113 UT45 !NAD IS!- 99A I SI 12 DISCHARGE F1ANGE - P!PE 10/30/97 C 5. 21 l
ISI- 99A W-19 97-0157 UT60 GEO j SI 12 DISCHARGE FLANGE - PIPE 10/30/97 C 5. 21 j
ISI-103 H- 1 97-0043 (A) VT3 NAD SI TEST RETUPN ROD / CLAMP 10/23/97 F-A C1 II
'97-0041 FT i, NAD 151-103 W-11 St TEST RETURN FIFE - VALVE 10/23/97 C 5. 30 KH 1-1189 / 1190 Lift Fixture 97-0038 MT l!ND Lift Big Internals Rx Internals 10/23/97 Nureg 0612 NC
~
~
97-0038R1 r NAD XH 1-1199 / 1130 Lift Fixture 10/25/97 Nareg 0612 NC Lift Rig Ir,ternals ;Px Internals
. Pepal.r
_ - . . . . . . . . . . . . _ . . . _ _ i. __. _
. NAD XHa!-304 .Rx Head Lugs 97-0159 MT h4 Head Ltft Lugs Rx Head 11/18/97 Nureg 0612 NC t
- - - - . . ...-._.....-....a--.
I I
1 1
l I
l l
l l
Page 10 03/10/98
NORTHERN STATES POWER
SUMMARY
REPORT INSERVICE INSPECTION PRAIRIE ISLAND UNIT 1,1997 APPENDIX B INTERVAL 3 PERIOD 2 INSPECTIONS BY ASME ITEM NUMBER 10 Pages I
4 i
l
e ,
Prairie Island Nuclear Generating Inservice Inspection Report Log Northern States Power Company 1717 wakonado Drive Third Interval By Source Doc # 414 Nicollet Hall welch, bei $5089 Commercial Service Date: December 16, 1973 Minneapolis, MN 55401 Item Report Number Method Results ISO System Item Description Exam Date ASME Section XI Item W- 6 97-0123 MT NAD ISI- 49 R.V. CLOSURE HEAD HEAD - FLANGE 11/03/97 8 1. 40 W- 6 97-0172 UTO NAD ISI- 49 R.V. CLOGURE HEAD HEAD - FIANGE 11/12/97 B 1. 40 Limited, Less than 904 W- 6 97-0173 UT45 ,NAD ISI- 49 R.V. CLOSURE HEAD HEAD - F1ANGE 11/11/97 B 1. 40 Limited, Less than 90%
W- 6 97-0175 UT60 iNAD ISI- 49 R.V. CLOSURE HEAD HEAD - F:ANGE 11/10/97 B 1. 40 Limited, Less than 90%
W- 5 97-0098 UTO -NAD ISI- 41 PRESSURIZER TCP HEAD / SHELL 10/29/97 8 2. 11 Limited, Exceeds 90%
97-0099 UT45 NAD
~~ISI- 41 W- 5 PRESSURIZER TOP HEAD / SHELL 10/29/97 B 2. 11 Limited, Exceeds 90%
W- 5 97-0100 UT60 'NAD ISI- 41 PRESSURIZER TOP MEAD / SHELL 10/29/97 B 2. 11 Limited, Exceeds 904 ISI- 41 W- 3 97-0144 UTO lNAD PRESSURIZER BOTTOM HEAD / SHELL 11/06/97 a 2. 11 i Limited, Exceeds 90%
97-0143 UT45 NAD TSI-41 W- 3 PRESSURIZER BOTTOM HEAD / SHELL 11/06/97 8 2. 11 Limited, Exceeds 904 97-0142 UT60 NAD
~ihi- 41 W- 3 B 2, 11 I PRESSURIZER BOTTOM HEAD / SHELL 11/06/97 Limited, Exceeds 90%
97-0164 UTO NAD ISI- 430 l W- A STEAM CENERATOR #12 l TUBE SHEET / HEAD 11/15/97 B 2. 40
! Limited, Exceeds 90% f 97-0165 i UT45 NAD ISI- 43B I W- A STEAM GENERATCR 412 TUBE SHEET / HEAD i11/17/97 !B2.40 Limited, Exceeds 90%
97-0171 UT60 NAD ISI. 43D l W- A STEAM GENERATOR 812 jTUDE SHEET / HEAD 11/10/97 B 2. 40 t_ent _E3ceeds,J.24 ____ ,
STEAM GENERATOR 511 10/23/97 8 2. 40
{TUBESHEET/ HEAD l
97-0150 MT NAD ISI- 37 lR.V. NUTS l
REACTOR VESSEL INUTS ,11/07/97 B 6. 10 mit pt 12 At _
PEACTOR VESSEL lSTULS '11/10/97 l B 6. 30
- - - . . . . - . y - - - - . . - - - . . . ---- - - - - - . - . --
3 j11/10/97 B 6. 30 REACTOR VESSEL , STUDS REACTOR VESSEL : WASHERS i11/07/97 B 6. 50
. . . ~ -
PLMP F' ANGE BOLTS .11/07/97 B 6.100 R:: PUMP 12
~ ~~
g3;- 3s
~ ' ~
'N FMON C 5 P' 97-3150 ^ " UT1 NA?
CONOCEAL BLTIN3 MAFMON C'. AMP .1/19/97 B' 10 R'
ISI- e '8- l' ~ ' 9'750156 ' V* I NAD Rip PEtt'PN 'A' B ETS F X ,E 10 00/9' B' 5$
SAO B- [ 97-0C93 VT1
~
Is't- 27A' '
MAL INJ LNP
- B' DJLT3 10/27/97 B E0 Page 1 03/10/08
t l
Prairie Island Nuclear Generating Inservice Inspection Report Log Northern States Power Company 1717 wakonade Drive Third Interval By Source Doc # 414 Nicollet Mall Welch, MN 55009 Cossaarcial Service Datet December 16, 1973 Minneapolis, MN 55401 ISO Item Report Number Method Results System Item Description Exam Date ASME 8ection XI Item 151- 34 B- 3 97-0145 VT1 1NAD I
RC PUHF 12 LOWER SEAL HOUSING 11/07/97 B1 f> 0 i
--4--
97-0146 VT1 ;NAD
_ISI- 34 B- 4 RC PUHF 12 UPPER SEAL HOUSING 11/07/97 B7 60 l l
ISI- 14 B- 3 97-0102 VT1 IND RC PUMP 11 UPPER SEAL HOUSING 10/29/97 B7 60 Deformed socket bead
___ISI- 14 B- 4 97-0101 VT1 IND RC PUMP 11 LOWER SEAL HOUSING 10/29/97 B1 60 Minor dents in threads ISI- 14 B- 4 97-0101R1 VT1 NAD RC PUMP 11 LOWER SEAL HOUSING 11/05/97 97. 60 Engineering evaluation B- 3 97-0102R1 VT1 NAD ISI- 14 RC PUMP 11 UPPER SEAL HOUSING 11/05/97 B 7. 60 Replaced bolt ISI- 3A B- 1 97-0010 VT1 NAD RHR LOOP ' A' VALVE BOLTING 10/21/97 B 7. 70 ISI- 19B B- 1 97-0012 VT1 NAD 8" RRR TAKE OFF 'B' VALVE BOLTING 10/21/97 B1 70
_ISI- . . . _ 3B W- 5 97-0127 PT [NAD RNR LOOP ' A' 45e ELBOW - PIPE 11/04/97 8 9. 11 l Limited exceedn 90% !
W-10 97-0132 [PT iNAD ISI- 19B 0" 9HR TAVE OFF 'D' ELB0W - FIPE 11/05/97 D 9. 11 9
. . .t ed , Exceeds 904 _
RHR LOOP 'A' 45e Ei. BOW - PIPE 11/04/97 f B 9. 11
.W-10 l UT45__ NAD
.ISI- 19B. . . . . - i l97-0133 B" PHP TAFE OFF 'B' fELBOW ~ PIPE 11/05/97 l' B 9. 11 l
97-0185 FT : NAD ISI- 2 lW- 5 ACC'IM . DISCHAPGE 'A' lELBDW-VALVE 11/25/97 j B 9. 11 IE.".7.2_I 97 ._C.EIIS7_.0 7 4 ,
__.__._._....__._4 , _ , , , _ , _ _ , , _ _ .
ISI- 2 lW- 5 i97-0100 i UT45 NAD ACL"'H . DISCHAPGE 'A' l ELBOW - VALVE I
11/25/97 f B 9. 11 4 97 f ?t l OEA [Q}7074 _,_ ,, . , ,
12" ACCLHULATOR D3CH PED. TEE - VALVE 11/25/97 8 9. 11
_97.10_r OEA.1997_074,___ _
. _ _ _ p. . . - r_- - - ,_
NAD ISI- 17. . - - - . . . . W- 7 97-0189 ! UT45 12" ACCUMULATOR OSCH : RED. TEE - VALVE 11/25/97 } B 9. 11 IN 97-19, OEA1997074,
. . _ . _ _ d_-_.__..--._.
W- 5
.._ ...i.... .-- -..-_-- ~-E1*D_ed,_ Exceeds _901 i97-0190 (A) UT60 NAC tsI- 2 ACCUH. DISCHABOE 'A' l ELBOW - VALVE !!1/25/97 ' B 9. 11
! IN 97-19, OEA 1997074
- . . . . ~ . _ . . _ . _ . . . _ . . _ _ . - _ . - ~ . . - . . _ - -
W- 1 (91-0191 (A) UT60 'NAD ISI- 17 i 12" ACCUH'::ATOR ISCH 9ED. TEE - VALVE f11/25/97 88 11
____ E.-_.___.--..'.....___. _ _ . - IN " 1 h OEA M *3 7 4 - .
i97-0129 PT ._ SAD..
l ISI- . IC_. ;W- 1 alar 1!N3 LINE 'B' iPirE - TEE :11/05/O B4 21 l
I I . . - . . - .
- ~
. Is!- 1r w- 6 j 97-JMC FT FIFE - 45# ELB0W 10124/97 0
- 21 CHARGING LINE 'B' CHAPT NG LINE 'e' 4Se E; BOW - P!rE l10/24/97 B 9. 21
. . _ . .s .
W 'Sh0093 FT N.C 131- "A c 8rRAY TO IRT.S$"HIZER ELON - FITE ,10/ 2 4 ' ? 9 9. I.
P898 2 03/10/D6 _. _ . - _ - _ _ _ _ _ _ _ _ . _ _ - _ _ _ _ _ _-_
Prairie Island Nuclear Generating Inservice Inspection Report Log Northern States Power Company i 1717 Wak.onada Drive Third 2nterval By Source Doc # 414 Nicollet Hall Welch, MN $5089 Cossaarcial Service Date: December 16, 1973 Minneapolis, MN 55401 ISO Item Report Number Method Results System Item Description Exam Date ASME Section XI Item ISI- LA W-10 97-0156 PT j NAD SPPAY TO PRESSURIZER PEDUCING TEE - PIPE 11/10/97 B 9. 21 i f
ISI- 6 W- 6 97-0105 PT 'NAD RTD RETUPN 'A' PIPE - ELBOW 10/30/97 8 9. 21 ;
'ISI- 6 W- 4 97-0115 PT IND l RTD RETURN 'A' PIFE - FLANGE 11/01/97 8 9. 21 Linear indications IS!- 8 W-22 97-0107 PT jNAD RTD TAFE OFF ' A' HOT PIPE - ELBOW 10/30/97 8 9. 21 l
' I 131- 27A W- 9 97-0094 PT lNAD SEAL INJ LOOP 'B' PIPE - r1ANGE 10/27/97 8 9. 21 l l
ISI- 26 W- 7 97-0119 PT 1 RAD 2" CVCS LETDOWN 'B' VALVE - P!PE 11/01/97 8 9. 21 ISI- 6 W- 4 97-0115R1 PT NAD RTD RETURN 'A' PIPE - FIANGE 11/21/97 8 9. 21 Engineering evaluation ISI- 46 W- 1 97-0116 PT NAD RCS DRAINDOWN P!PE - NOZZLE 11/01/97 8 9. 31 g i
ISI- 46 IW- 1 97-0148 UT45 NAD RCS CAAINDOWN PIPE - NOZZLE 11/15/97 8 9. 31
~
'I5i W A" V- 1 97-0192 ? VT3 6NAD Pf. ACTOR VESSEL S!S A VALVE INT SUFFACES 10/26/97 fB12.50 ISI- 48 iVESSEL INTR 97-0122 jVT3 . NAD REACTOk VESSEL lVTINTLSURFACES 11/03/97 ;B13.10 This report will not be j
. ~ . _ . . . . . . . . _ _ _ , . . _ . _ . j..__ ! ._
CIIgited ,,as,,2_,n1 period exam. {
ISI- 49A :W-04 97-0124 PT , Nr.,
PV fop Head CRD-04 Heusin9 Weld 11/03/97 ' B14. 10 l _
RV Top Head t.CRD-:6 Housing Weld 11/03/91 B14. 10 l f
. _ . . . . _ ___a_.-..... &____..__._._ _
j 97-0077 (A) UT60 NAD I>I- 43A i W- F STEAM GENCRATOR 811 [ TRANSITION - SHELL 110/25/97 C1 10 1
l ISI- 43A } W- F l97-0076 (Al UTO NAD STEAM GENEPATOR #11 fTPANSITION-SHELL 10/25/97 C 1. 10 I
i j97-0004 UT45 NAD ISI- 9?B ; W- 1 PHR HEAT EXCH 12 !10/11/97 C 1. 20 l HEAD-SHELL
_ _ . . . _ _ _.4.._.-,._ . . _ _ _ _ . - _ _ _ . _ , _ _ _ _ _ _
_ _ Limited, less than 90% ,. ,
151- 43A_ . . . . . . ~ . . _ ! W- H !97-0091 (A) UT60 NAO STEAM GENERATOR all TCP HEAD - SHELL 10/27/97 C 1. 20
-- : u_...-. . _ . . _ i 131- 43A. . _ . . . _ _ . . _ . .! W- _ .H. _ . _ _ L j97-0000 __ _ _._(Al UT45 _ . . . _NA: l STEAM GENERATOR til l TOP HEAD - SHELL l10/27/97 C 1. 20 3 101- 43A . W- H ; 97-0079 ( A) UTO NA*
f STE/+t GENERATOR fil 'TCP HT.AD - SHI.1.L '10/27/C C 1. :0
' W- B EI-0 ! f.1 P' A' l- 4 ?h '
TEAM cENERATon at: T"BE N ET - EHELL 11/19/97 0
- M i 1
1
~ ., h 01 s f ' ' ~
~ ~
111J 433 'w. p' 7T45 SAL STLAM GENERAIOR 912 lT('BE$HEET
- SHELL 11/19/97 C 1. 30 L!M t ed, Excee- s a:n
,51- 439 W- 9 97-0163 "Te4 NAD CTUV4 GENE RATCR #12 ;TUBESMTET - SkE; 11/19/07 0 1. M Latted, E:< : ead s Q P898 3 03/10/00 L________________ _ _ _ _ _ _ _
i I
e Prairie Island Nuclear Generating Inservice Inspection Report Log Northern States Power Company 1717 wakonade Drive Third Interval By Source Doc # 414 Nicollet Mall l
l Welch, W 55089 Cossnercial Service Date: December 16, 1973 Minneapolis, W 55401 ISO Item Report Number Method Results System Item Description Exam Date ASME Section XI Item W- 4 LS U 2D 97-0131 l PT INAD ISI- 53C RHR SUCTION PUMP 'A' PI"UCER - RED. TEE 11/05/97 C 5. 10 i
W- 4 LS U 2D 97-0136 UT45 1NAD 3 1- 53C FHR SUCTION PUMP 'A' REDUCER - RED. TEE 11/05/97 C 5. 10 l i
W- 5 LS 2U D 97-0130 PT NAD IS!- 53C REDUCING TEE - PIPE 11/05/97 C 5, 10 RHR SUCTION PUMP 'A' ISI- 53C W- 5 LS 2U D 97-0135 UT45 NAD PHR SUCTION PUMP *A' REDUCING TEE - PIPE 11/05/97 C 5. 10 ISI- 89A W-21 97-0047 PT j NAD RHR PUMP "A" DISCH VALVE - PIPE 10/24/97 C 5. 11 !
I W-21 97-0056 UT45 NAD ISI- 89A RHR PUMP "A" DISCH VALVE - PIPE 10/25/97 C 5. 11 97-0048 PT NAD ISI- 89A W-22 RHR PUMP "A" DISCH PIPE - ELBOW 10/24/97 C 5. 11 97-0057 UT45 NAD
~5SI- 89A W-22 RHR PUMP "A" DISCH PIPE - ELBOW 10/25/97 C 5. 11 97-0046 PT NAD ISI- 898 W-29 PHR PUMP 'D' DISCW , PIPE - 55e ELBOW 10/24/97 C 5. 11 j I l TSIA B90
~
97-0058 l UT4 5 jNAD fW-29 PHR PUMP 'B' DISCH PIPE - 55e elbow 10/25/97 l C 5. 11
~ ~ ~ ~
'~
- NAD Isi l s W-19 97-0042 PT C 5. 21 SI 12 DISCHARGE FIANGE - PIPE 10/21/97 97-0113 I UT45 NAD I' sit 9'iA W-18 i SI 12 DISCHARGE PLANGE - PIPE 10/30/97 i C 5. 21 J
151. %A E2 97-0055 PT - NAD SI 11 DISCHARGE REDUCER - PIPE 10/25/97 i C 5. 21 .
4 1 !
l PED'???R - PIPE l10/30/97 C 5. 21 S! 11 DISCHARGE I + -_ .
ELBOW - PIPE {11/01/97 C 5. 21 SI 11 DISCHARGE I i - .- - . . - - - . .. - -
S! 11 DISCKARGE ; ELBOW - PIPE 11/01/9' C 5. 21
_p..___...__... . . . - - . . . - . - - - . - ~ . - - . - -
- . . . . -_ ~_
10/30/97 C 5. 21 SI 12 DISCKAAGE f PIANOE - PIPE
._.--.-.-.-...l-..-- ' W- 2
}97-0158 U760
. OED 151- 98A ,
SI 11 DISCHARGE REDUCER - PIPE !10/30/97 ' C 5. 21 i97-0041 PT NAD 151-103 lW-11 l !I TEST RET;?kN iP!PE - VALVE ,10/23/91 C5 30
~
~ kI 131- 510' WA 6 bTN ' A505 d IIAD 10/20/U C- 53 MAIN STEAM 'A' 45J ELPJW - PIFE
' W'. ' e U' c ;6 ~ '970$i ~ ~ ' U}45
^
Sto
- 16. ' 51 p"'
MAIN STEAM 'A' 45e ELB0W - PIPE '10/29/97 Ci $ ?.
-+ - - - ~~- - - -
--- -- g
%IN $ TEAM 'A' iFIFE - CAP '10/22/97 C5 50 Page 4 03/10/20
I Prairie Island Nuclear Generating Inservice Inspection Report Log Northern States Power Company 1717 Wakonada Drive Third Interval By Source Doc 0 414 Nicollet Hall Welch, MN 55089 commercial Service Dater December 16, 1973 Minneapolis, MN 55401 ISO Item Report Number Method Results System Item Description tram Date ASME Section XI Item ISI- 51C W-13 LS U 97-0035 UT45 i NAD MAIN STEAM 'A' PIPE - CAP 10/22/97 C 5. 50 i
ISI- 660 W-18 LS U 97-0000 MT ; IND MAIN 3 TEAM 'B' PIPE - CAP 10/21/97 C 5. 50 j I
Linear indications ISI- 60C W-18 LS U 97-0036 UT45 iNAD MAINSTEAM *B' PIPE - CAP 10/22/97 C 5. 50 l
1
'ISI- 60C W-18 LS U 97-0000R1 MT NAD MAINSTEAM 'B' PIPE - CAP 11/03/97 C 5. 50 Repair ISI- $1C W-17 LS U 97-0186 (Al MT !NAD MAIN STEAM 'A' PIPE - CAP 11/26/97 C 5, 50 IGI- t>BC W-12 LS U 97-0167 (A) MT lNAD MAINSTEAM 'B' P1FE - CAP 11/26/97 C 5. 50 ISI- 68C W- 3 97-0011 MT NAD MAINSTEAM 'B' PIPE - ELBOW 10/21/97 C 5. 51 ISI- 60C W- 3 97-0017 UT45 GEO MAINSTEAM 'B' PIFE - ELBOW 10/21/97 C 5. 51 ISI- 52 W-12 97-0160 MT lNAD TEECWATER LOOP 'A' ELBOW - PIPE 11/20/91 C 5, 51 i
ISt- 52 W-12 97-0176 UT45 jNAD t'EE0 WATER LOOP 'A' ELBOW - PIFE 11/21/97 C 5. 51 I i
a.
I
..;_ __ _ ____.__. 4 FEEC WATER LOOF ' A' REDUCER - N0ZZLE 11/08/97 ; C 5. 51
~ _ . . _ . ._.,_4'. _.}__ - : GEO ISI- 52 W-23 i97-0153 (A) ;
UT60 FEEDWATER LOOP 'A' REDUCER - NO ZLE l11/09/97 - C 5. 51
- 97-3031_ _ _ . _ . _ _ MT NAD
. . _ . - . {W-. _ _ . _2 . .
. . . _ _ . . .ISI- 52 _.
FEEDWATER LOOr 'A' 10/22/97 C 5. 51 6 HELB l PIPE-ELBOW i l
- _ - . . _ - . - . - - . .a... a.-. - -.- , - -. _...-.
ISI S2 j W- 2 497-0051 UT45 NAD FEEDWATER LOOP 'A' l PIPE - ELBOW l10/24/97 C 5. 51 & HELB i j ISI- SIC iW-12 97-0033 MT .NAD MAIN STEAM 'A' PIPE - FLANGE 10/22/97 C 5. 80
.-...-..-._..v._ +.-- -a . _ . . - _ _ . . . -
.ISI- 69C. . _ . - . - iW-11 !97-0128 HT NAD MAINSTEAM 'B' {11/05/91 " 5. 60
[ FIPE - r!ANGE NOZ 1.E ISI-... 0 iH . .97-0085 (A) PT NAD ACCUM. DISCHARGE 'A' ISrRING 10/21/97 r-A . B10. 10 i
Toll.tw-up e_xam_ , _ _ _ _ _ _
1$1- 2 'H- 3 697-0066 (Al . VT3 IND ACCUM. DISCHARGE 'A' GrRING i10/20/97 F-A 6 B10. 10
! Follow-up exam, concrete i
'97-0016. IA)
_ . . . . _ . _ YT3 . . ._ ._8P811107,.108:1 Settin9-NAD 151* 3C H- e l j
PG LOOP 'A' qROD RANSER 10/21/97 F-A & BIO. 10
~~
Is!~'[ )h.'3~ [9500M1 (A: 5
/73 4
(
A:'C' H . DISCHANGE 'A' !SFRINO 11/0(/97 F-A & P10. 10 {
, Engir+ering evaluatic
- A2 IS!- 14' H- 1 U-0059 VT3 RC FiHF 11 ' TIE BACK f 1 il2/05/9' T-A & B10. 20
^ ' h-Nig "
~
u t ' 3 4' }gl 3
'~
yti " e RC ITHF 12 ?!E PLUK 4 3 10/25/9' F-A & B10. 23 l
1 Page 5
, 01/10/98 u________.___._ __
Prairie Island Nuclear Generating Inservice Inspection Report 1.og Northern States Power Company 1717 wakonade Drive Third Interval By Source Doc # 414 Nicollet Mall welch, MN 55089 Commercial Service Dates December 16, 1973 Minneapolis, MN $5401 ISO Item Report Number Method Results
_. System Item Description Exam Date ASME Section XI Item 97-0067 (Al VT3 'NAD NI- 34 H- 1 PC PU'iP 12 TIE BACK 91 10/25/97 F-A & B10. 20 ISI- 93B H- 1 91-0005 VT3 .IND RHR HEAT EXCH 12 SUPPORT 10/17/97 F-A & C 3. 10 Concrete spalling I ISI- 938 H- 1 97-0177 PT IND PHR HEAT EXCH 12 SUPPORT 11/24/97 F-A & C 3. 10 Linear indication H- 1 97-0005R1 VT3 NAD ISI- 939 PHR HEAT EXCH 12 SUPPORT 11/04/97 F-A & C 3. 10 Engineering evaluation H- 1 97-0177R1 PT NAD ISI- 938 SUPPORT 12/01/97 F-A & C 3, 10 RH3 HEAT EXCH A2 Repair H- 1 97-0141 VT3 'NAD
___.ISI- 680 MAINSTEAM 'B' BEAR'G BRAK ASSY 10/20/97 F-A & C 3. 20 H- 1 97-0028 VT3 NAD ISI- SIC MAIN STEAM 'A' SUPPORT BRAK ASSY 10/22/97 F-A & C 3. 20 l
Code Case N-491 l 97-0166 MT NAD
_ISI- 52 H- 6 FEEDWATER LOOP 'A' ANCHOR ELBOW 11/20/97 F-A & C 3. 20
^
E51-T H- 6 97-0167 VT3 lNAD FEEDWATER LOOP 'A' ANCHOR elbow 11/20/97 F-A & C 3. 20 !
1SI- 52 H- 5 97-0174 Ms lIND IEEDWATER LOOP 'A' RESTRAINT 11/20/97 T-A & C 3. 20 <
~ h7-0169 3 ;NAD ISl- 52 )H- 5 EEEDWATFP LOOP 'A' [ RESTRAINT 11/20/97 l F-A & C 3. 20 i I l
..---.y 97-0030 ' MT , NAD ISI- 52 ,H- 1 FEELWATEP. LOOF 'A' ;SIECMIC RESTRAINT 10/22/97 lF-A& C 3. 20 i
131- 52
-...-.m iH- 1 97-0078 ! VT3 IND--
FEEDWATER LOOF 'A' jsIESMICPESTRAINT 10/27/97 F-A & C 3. 20 0?'.h.u_t. y d_gsp _ _ _ . _ _ _ _ _
MAIN STEAM 'A' lSUFFORTBRAKAS3Y l10/23/97 ! F-A & C 3. 20 l [ Limited, Less than 90%
{H- l97-0039 l MT .NAD A$1- MC l 1
MAIN 3?EAM 'B' [ BEAR'G BRAK A30Y 10/2.s/97 - F-A & C 3. 20 l L_ . LLinkted,, Leas than,9M ._ _ , _ _ l MT NAD 131- SIA.. ._ l H- 5. . . . _ , . . _ . . . . _ . _ _ l 97-0097 (Al
- DEAR'G 9BAK A32Y (3) l10/25/97 F-A & C 3, 20 MAIN STEAM 'A' Limited, Less than 901
- . . _ . . _ _ _.L--. ,_
NAD
. . - . . . . . _IS!- 51A {H- 6 i97-0006 lAl MT MAIN 37EAM 'A' : BEAR'G BRAK AS3Y 13) i 10/25/97 , F-A & C 3. 20 I t'da ..Le_s s _t hag _9Ct_ __ _
SIESMIC #ESTRAINT l11/06/91 ; F- A & C 3. 20 FEE DWATER LOOP ' A' fPework and Engineering
~
'H-5 b d d4R1 ' NdD ~
IhI- 52
!RFSTRAINT 11/05/97 T-A & C 3. 20 FEEDi=ATER LOOP 'A' Er. ;ireeri c q eva l .;at icn H- 2 9'UC 3 'C 3 e
'lI- 1A CHAT GING LINE 'B' FNUBPEF 10/23/97 F-A Ci !
,P-0013 tAl 'M 3 NA
- 39 4- e bd LOOF 'A' 'EUFTUDE FESTRAINT 10/25/97 F*A C1 I
~
,c,.
3g
- g. * {A7'.g;f 63 ;;A; En trP 'A' SIE.?MI2 RESTRAINT 10/21/ C F-A C1 I Page 6 03/10/06
Prairie Island Nuclear Generating Inservice Inspection Report Log Nort.hern States Power Company 1717 wakonede Drive Third Interval By Source Doc # 414 Nicollet Mall welch, DN 55089 Commercial Service Date: December 16, 1973 Minneapolis, MN 55401 ISO Item Report Number Method Results System Itera Description Exam Date ASME Bection XI Item ISI- 3B H- 8 97-0007 VT3 lIND RHR LOOP 'A' ROD 10/21/97 F-A C1 I {
No load on rod ISI- 5A H- 4 97-01378L VT3 NAD SPRAY TO PRESSURIZER HYDR SNUBBER / CLAMP 11/13/97 F-A C1 I ISI- 27B H- 2 97-0147 VT3 NAD SEAL INJ LOOP 'B' ANCHOR 11/07/97 F-A C1 I ISI- 21 H- 1 97-0002 VT3 NAD 3" RTD RETURN LOOP B PUP'T RESTRAINT 10/27/97 F-A C1 I ISI- 26 H- 3 97-0090 VT3 NAD 2" CVCS LETDOWN 'B' SPRING HANGER / CLAMP 10/28/97 F-A C1 I ISI- 26 H- 1 97-0089 VT3 NAD 2" CVCS LETDOWN 'B' HYDR SNUBBER 10/28/97 F-A C1 I ISI- 14 H-10 97-0021 VT3 NAD RC PUMP 11 BASE 9 1 10/21/97 F-A C1 I ISI- 14 H-10A 97-0022 VT3 NAD RC PUMP 11 COLUMN BCT & PIN 9 1 10/21/97 F-A C1 I
~
~iSI'- 14 H~ 1A 97-0060 VT3 NAD PC PUMP 11 TIE BACK BOLT 9 1 10/2$/97 F-A C1 I ISI- 14 H- IB 97-0061 VT3 lNAD I
PC PUMP 11 TIE BACK PIN 9 1 10/25/97 I F-A C1 1 i F-A C1 I i RC PUMP 11 1 FAD 1 f10/25/97 ISI- 14 H- 7 97-0063 lVT3 l NAD RC Pt!MP 11 CONNECTION e 1 10/25/97 l F-A C1 I l l !
ISI- 43C H-25 97-0024 i VT3 NAD STUW GENERATOR 811 lFsASE 9 1 10/21/97 . F-A C1 I t !
l
. . . . ~ . . . _ . . . - _ . ~ _
STEAM GENr.RATOR #11 PIN 9 1 10/21/97 F-A C1 I lCOLUMNDOT&
STEAM CENEPATOR #11 BASE 9 4 11/25/97 ' F-A C1 I IS!- 43C iH-24B !97-0181 i VT3 ' NAF STE7M GENEBATOR eli jCOLUMNBOT& PIN 9 4 F-A C1 I l11/25/97
.- . -.~
STEAM GENEPATOR pil ' TOP CONNECTION 91 i11/18/97 F-A C1 I f .
.. . . _ _ ~ . . _ . . _ . . _ _
STEAM GENEPATOR ell 11/16/97 F-A Ci !
{CCLUMNTOP& PIN 9 1 i i
- . - . _ . - - .- - - _ - - _ _ _ _ _ _ . _ _ _ . _ _ _ . ~ . . _ _ _ . ._
STEAM CENERATOR 811 !TCP CONNECTION 9 4 10/21/97 F-A C1 1 Bp1t npt flush with. plate _ _ _
ISI- 430. . . : H-24A 97-0019 VT3 NA FTC/d Of.NFRATOD all 1 COLUMN TOP & PIN 64 10/21/97 F-A Cl I STEAM GFNEkATOR 911 !TCF SUFFORT GIFPER 10/24/97 F-A C1 I
!H-10 '97-0027 VTh NE ICI- 43C STEM GENEAAh'.$ til FI An'RE 10/21/97 F-A C1 I
~ _. ..
Page 7 j c3/10/93 i
e 8 L Prairie Island Nuclear Generating Inservice Inspection Report Log Northern States Power Company 1717 Wakonade Drive Third Interval By source Doc # 414 Nicollet Mall welch, Mi 55089 Comeercial Service Date: December 16, 1973 Minneapolis, H:4 55401 Iso Item Report Number Method Results System Item Description Exam Date ASME Section XI Item ISI- 43C H-11 97-0026 VT3 NAD STEAM CENERATOR fil FIXTURE 10/21/97 F-A C1 I ISI- 43C H-12 97-0025 VT3 j NdD STEAM GENERATOR fil FIXTURE 10/21/97 F-A C1 1
~ISI- 43C H-13 97-0183 VT3 NAD STEAM GENERATOR #11 PAD 11/25/97 F-A C1 1 151- 43C H-16 97-0104 VT3 NAD STEAM GENERATOR ell PAD 11/25/97 F-A C1 I 151- 43C H-17 97-0178 VT3 IND STEAM GENERATOR All BUMPER block 11/25/97 F-A C1 I Lack of thread engagement ISI- 43C H-20 97-0020 VT3 NAD STEAM GENERATOR 411 BUMPER BLOCK 10/21/97 F-A C1 I ISI- 44 H- 1A 97-0139 VT3 NAD REGEN HEAT EXCHANGER FLOORSTAND 11/06/97 F-A C1 I ISI- IB H- 4 97-0139 VT3 NAD CHARGING LINE 'B' 1ATERAL RESTRAINT 11/06/97 F-A C1 I ISI- IC H+ 1 97-0126 VT3 NAD CHARGING LINE 'B' ANCHOR 11/04/97 F-A C1 I ISI- 34 H-12 97-0074 VT3 NAD RC FUMP 12 BASE 9 3 10/25/97 F-A C1 I i
I RC FUMP 12 COLUMN BOT & PIN 8 3 10/25/97 F-A C1 I :
i 4 __ _ _ . .
I RC PUMP 12 lTIEBACVsoLT 93 10/25/97 F-A C1 I
. . . ~ . .ISI- 34
._..._...__) __
97-0070 I
jNAD lH- 3B l VT3 PC PUMP 12 TIE FsACE PIN 93 10/25/97 lF-AC1I RC PUMP 12 l PAD 3 10/25/97 F-A C1 I
. . . - . - _ _ . . _ - . . . . . _ _ _ . . . . ~ -
HC FUMP 12 CONNECTION 9 3 10/25/97 !F-AC1I I
.- . - - ~ _ - . ~ . ._ - - . . _ -
RC TUHF 12 COLlHN TOP & IIN 9 3 10/25/97 F-A CI I 191- 11C ,H- 3 !97-0104 (A) i VT3 NAD EEAL INJ Lo0P 'A' ROD Cl#4r l10/30/97 ' I I
- t
. __._.' F-A C1 1_ _ _ _ _ . . . _ . _ _ _ . . . , . . _ _ _ .
DRN TON CPOSSOVER) A 10BLE SPRING / BENT BAR l10/3D/97 F-A C1 I !
-.- . - . _ _ - . --+ . .. _ . - .- l .
- ML . -
2" CVC0 LETCOWN 'B' iHYCR $NUBBEP/C1. AMP '10/29/97 F-A C1 I
~ -
. --._a . ~ . . . . - - - . . . .
STRAY TO TkESSVRIZER , DJ.W.E !NUBBER /CIAMP 11/25/P T-A Ji I is:- 31 H- 2 97-0121 (Ai V'3 DAD rFFF3"F12ER RELIEF i R'.T"GE RFSTPA!NT 11/0b 97 T-4 C1 I
)
mg -
tq m _be g a az --
SC T"HP 11 . COL"MN Tcr 6 FIN # 1 22/2$/O r-A C1 I Page g 03/10/06
r--- --- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
e * ,
Prairie Irland Nuclear Generating Inservice Inspection Report Log Northern States Power Company 1717 wakonado Drive Third Interval By Source Doc 8 414 Nicollet Mall welcA HN 55089 Commercial Service Date: December 16, 1973 Minneapolis, MN 55401 ISO Item Report Number Method Results System Item Description Exam Date ASME Section XI Item ISI- 3C H- 1 97-0014 (A) NAD j {VT3 PHR LOOP 'A' HANGE.R 10/21/97 r-A C1 I ISI- 14 H- BA 97-0065 (A) VT3 : hAD RC PUMP 11 COLUMN TOP & PIN # 2 10/25/97 T-A C1 I
, i l
ISI- 34 H- BA 97-0054 (A) VT3 IND RC FUMP 12 COLUMN TOP & PIN 9 2 10/25/97 r-A C1 I Support in contact with pump casing ISI- E H- S 97-0066 (A) VT3 i NAD RC PUMP 11 PAD 2 10/25/97 F-A C1 I !
_ISI- 3B LH- 0 97-0007R1 . VT3 iNAD RHR LOOP 'A' RCD 10/30/97 F-A C1 I Reworked '
~ ~
III- 43C H-24 97-0019R1 VT3 i NAD STEAM GENERATOR #11 TOP CONNECTION 9 4 11/04/97 r-A C1 I l'
Engtreering evaluation 4
ISI- 34 H- 8A 97-0054R1 (A) VT3 NAD RC PUMP 12 COLUMN TOP & PIN 9 2 11/05/97 T-A Cl I Engineering evaluation
~IUT 10 H. 2 97-0103R1 (A) VT3 lIND DRN (ON CRO3SOVER) A OBLE SPRING / BENT BAR 11/06/97 T-A C1 I Rework, bent rod ISI- 10 H- 2 97-0103R2 (A) VT3 INAD CSN (ON CROM OVER) A DBLE SFPING/ BENT BAR 11/07/97 F-A C1 I Engineering evaluation 131- 43C H-17 i97-0178R1 iVT3 NAD STUJ4 GLUERATOR 611 BUMPER BLOCK ! !1/26/97 T-A Cl I b?i3.0f'!nqevaluation 1 !
ISI- 999 ._ ..
.._..__._._..%_ - - _ - _ _ ; 97-0045 ; VT3 NAD j H- 7 !
PHR FtHP '
D' DISCH ! RICID MANGTR/ CLAMP I
'l0/24/97 i F-A C1 II l
l
......~...~..____..._.__.____+_ NAD 151- 53C (H- 1 ;97-0140 : VT3 F<HR S'KTION PUMr ' A' !' ANCHOR (STRUT) t11/06/97 r-A C1 II I
_r._ ~ _ m__--_. .- __ . . _ ,
NAD _
j97-C006
._ISI- 99A. . . _ - _ . . . . - - - . _ . . . . ' VT3 l H- 3 til 12 DISCHARGE ! RCD / CLAMP {10/20/97 F-A C1 II I i tSI- 968 : H- 1 <97-0117 . VT3 NAD SI 11 LISCHARGE fBOXSUFFORT !11/01/97 F-A C1 II
, i i ISI- SIC iH- 3 l97-0029 (A) ! VT3 NAD iMIN ST0/iH 'A' iCONST SUFPORT l10/22/97 F-A C1 II u . _ . . - - _ , - , . - . _
._r_s.
_m -._ s .. . . . - , - . - - - - - -
+%
Cl TE$T PET 14N ! POD / CLAMP f10/23/97 ,
F-A C1 II
', 97-0114 MT NAD 151- ElB :H- 3 MAIN STfAH A' , S FR IN3 HAN'3E.R 110/31/97 T-A C1 II 15!- 43R 197-0092 - MT NAD lN- 1 IN-IR NC IN 93-20 STUD 4 GENERATOR #12 >FEEDWATER NOZZLE 110 / 2ft / 97
.~.-..__..._d.,__. . _ . . . _ . . . _ _
97-0094 _ _ _ _ .VT3_ _ _ . . . NAD
, 131- 43B :N- 1 P!N3 TEE- _ . - - -
STEM GENERATvR sl. IN RIM TEE /SUFF09TS 10/28/91 NC IN 93-20 9i -0 M '. ,A:
19!- 41B W- F *
?ILM SEMRK 612 TEAM WELD INT "* 2/20/ 0 NC IN 03-2;
.I- ta 'N.- ; r,3. ; 0 '960b$f ~ eta $
FLEWATER Lec t 'B' PENCER - N0;ILE 10/24/97 NC IN 33 M
~
151- to ' w 2 '- ;N 03-20 '97-0053' UT+c - .-
FLEMATER LNP 'H' 'Ptr"!Ek - HO3 2 LE 10/24/9 NO IN 93-2^ f l
Fage 9 I 03/10/93
e .
Prairie Island Nuclear Generating Inservice Inspection Report Log Northern States Power Company 1717 wakonado Drive Third Interval By source Doc # 414 Nicollet Mall Welch, W 55089 Commercial service Dater December 16, 1973 Minneapolis, MN 55401 ISO Item Report Number Method Results System 7 tem Description Exam Date ASHE Section XI Item Hx 1-1397 Lift rixture 97-0001 4 MT lNAD Px Head Lift Fixture Rx Head 06/05/97 lNoreg0612N I I HX .1-1397 Lift fixture 97-0002 VT1 i IND Px Head Lift rixture Rx Mead 06/05/97 Nureg 0612 NC Hissig roll pins .
XH 1-1189 / 1190 Lift Fixture 97-0038 MT IND Lift Pig Internals Rx Internals 10/23/97 Nureg 0612 NC Linear indication -
ioceton Dwg 883C173 062-111 97-0003BL MT NAD Turbine Fpreader Spreader beam 09/12/97 Nureg 0612 NO W E1397 Lift Fixture 97-0002R1 VT1 lNAD Px Head Lift Fixture Rx Head 10/20/97 Nureg 0612 NC l )
Roll pins are left out for maintenance adjustment prior d 97-0038R1 to each lift, J XX 1-1189 / 1190 I
Lift rixture MT NAD Lift Rig Internals Rx Internals 10/25/97 Nureg 0612 NC Fepair XK-1-384 Rx Head Lugs 97-0159 HT NAD Rx Head Lift Lugs Rx Head 11/18/97 Nureg 0612 NC 15I- 34 PUMP #12 97-0109BL FT NAD PC FUMP 12 FLYWHEEL f(EYWAY & BOPE 10/30/97 TS 4.2-1 .
I -
10/30/97 TS 4.0-1 I kC PUMP 12 ELYWHEEL ' KEYWAY & BOFE I
!P'!MF #12 [97-0110 I UTO rNAD 151- 34 I
HC P"MP 12 FLYWHf,EL BCDY l 10 / 30/ 97 !TS4.2-1 j
i . - -- i PC ftt4P 12 FLYWRVEL lFEPtrHERY 10/30/97 : TS 4.0-1 '
l !
Page 10 03/10/90
l NORTHERN STATES POWER
SUMMARY
REPORT INSERVICE INSPECTION PRAIRIE ISLAND UNIT 1,1997 APPENDIX C INTERVAL 3 PERIOD 2 INSPECTIONS BY INSPECTION REPORT NUMBER 10 Pages
e
- e ,
! Prairie Island Nuclear Generating Inservice Inspection Report Log Northern States Power Company 1717 Wakonade Drive Third Intarval By Report # 414 Nicollet Mall Welch, M4 55089 Commercial Service Date December 16, 1973 Minneapolis, MN 55401 l
ISO Item Report Number Method Resulta system item Description Exam Date ASME Section XI Item l
HX 1-1397 Lift Fixture 97-0001 MT NAD
{
Rx dead Lift Fixture Rx Head 06/05/97 Nureg 0612 NC HX 1-1397 Lift Fixture 97-0002 VT1 IND Rx Head Lift Fixture Rx Head 06/05/97 Nureg 0612 NC Hissing rL11 pins l
MX 1-1397 Lift Fixture 97-0002R1 VT1 NAD I Rx Head Lift Fixture Rx Head 10/20/97 Nureg 0612 NC )
Roll pins are left out for I maintenance adjustment prior to each lift. l Foreign Dec 883C173 062-111 97-0003BL MT NAD Turbine Spreader Spreader beam 09/12/97 Nureg 0612 NC ISI- 93H W- 1 97-0004 UT45 NAD RHR HEAT EXCH 12 HEAD - SHELL 10/17/97 C 1. 20 Limited, less than 90%
ISI- 93B H- 1 97-0005 VT3 IND RHR HEAT EXCH 12 SUPPORT 10/17/97 F-A & C 3. 10 Concrets spallinq 151- 938 H- 1 97-0005R1 VT3 NAD RHR HEAT EXCH 12 SUPPORT 11/04/97 F-A 6 C 3. 10 Engineering evaluation ISI- 99A H- 3 97-0006 VT3 NAD SI 12 DISCHARGE ROD / CLAMP 10/20/97 F-A C1 II ISla 3B H- 8 97-0007 VT3 IND RHR LOOP 'A' ROD 10/21/97 F-A C1 I
~~~~
No load on rod
'ISI. 3B H- 8 97-0007R1 VT3 NAD RHR LOOP 'A' RCD 10/30/97 F-A C1 I Reworked 151- teC W-18 LS U 97-0008 MT IND MAINSTEAM 'B' PIPE - CAP 10/21/97 C 5. 50 Linear indications :
ISI- 680 W-18 LS U 97-0008R1 MT }NAD MAIN 3 TEAM 'B' PIFE - CAP 11/03/97 C 5. 50 ISt- 3B N- 7 97-0009 3 NAD RHR LDOP 'A' {SIESMICRE5TRAINT l
10/21/97 F-A C1 I ISI- ...3A b B- 1 97-0010 VT1 ; NAD RkR LOOP 'A' VALVE BOLTING 10/21/97 87 70 I5!* 6SC W- 3 97-0011 NAD l MT MAINSTEAM 'B' 10/21/97 C 5. 51 l FIFE-ELBOW ~
g sjZ {9g' ~ 97-0012 VT1 'kAb l B- 1 8" RHR TAFE OFF 'B' 10/21/97 B1 70 lVALVEBOLTING
.---t g RHR LOOP ' A' RUFTURE RESTRAINT 10/21/97 l F-A C1 I i - - - - -
RRR LOOP 'A' HANGER !10/21/97 lF-AC1I l STEAM GENERATCP 411 TCP CON-CO!CN 91 11/18/97 F-A 01 I l
151- N iHk i' 97-0016 (At V3 NAD RPR loor *A' . RCD HA%ER '10/21/97 F-A & BID. 10
~ . -- . . ~ . - - + - - - .- _ .
M!NSTEAM *B' l FIFE-ELBOW 10/21/97 0 5. 51
_ _ -- --. - . - . __ _- , _ . -- ~ __
STEAM GENERATOR 911 l10/21/97 F-A C1 I l TOP CONNECTION e 4
, _ , . 3 _ . _ . . _ _ -
.B lt nct flush with plate 03/10/98 "'* I
e * .
Prairie Island Nuclear Generating Inservice Inspection Report leg Northern States Power Cong:,any 1717 Wahonada Drive Third Interval By Report 0 414 Nicollet Mall Welch, MH 55089 commercial Service Dates December 16, 1973 Minneapolis, MN 55401 (80 Item Report Number Hethod Results ftem Description ASME Bection XI Item J eteu Exas Date IS!* 43C H-24 97-001BR1 l VT3 NAD j STEAM GENEPATOR #11 TOP CONNECTION 9 4 11/04/97 { F-A C1 I
_ . . _ _ _ . _ _,.__.i ! E".91."M f1_ng evaluation IS!- 43C H-24A 97-0019 : VT3 . NAD STEAM GENEPATOR eli COLUMN TGF & PIN 9 4 10/21/97 F-A C1 I l NII 43C H-20 97-0020 VT3 i NAD STEAM GENERATOR #11 BUMPER BLOCK 10/21/97 F-A C1 I r ISI- 14 H-10 97-0021 ' VT3 ;NAD PC PUMP 11 BASE 9 1 10/21/97 F-A C1 I ;
IS!- 14 H-10A 97-0022 VT3 ' NAD RC PUMP 11 COLUMN BOT 6 FIN 9 1 10/21/97 F-A C1 I t 1
^!SI- 43C H-21B 97-0023 VT3 NAD STEAll ",ENERATOR ell COLUMN BOT & PIN 9 1 '10/21/97 F-A C1 I I
101- 43C H-25 97-0024 VT3 L* L STEAM GENERATOR ell BASE 9 1 10/01/97 F-A C1 I ISI- 43C H-12 97-0025 VT3 NAD STFAM CENEPATOR #11 FIXTUPE 10/21/97 F-A C1 I ISI- 43C H-11 97-0026 VT3 INAD STEAM GENERATOR ell FIXTUPE 10/21/97 F-A C1 I
..-. - s .
ETEAM GENERATOR #11 FIXTUPE e10/21/97 5
F-A CA I I
. . . ~ _ . _ . _ . . . - _ _ . _ . . . . _ _ . - l__ _ ..
NAD _
ISI- 51C ..H- I t97-0028 ! VT3 MAIN STEAM 'A' GUPPORT BRAK ASSY 10/22/97 lF-A&C3.20
~
!$1- 51C H- 3 97-0029 (A) ~O'AD MA!N STUJ4 'A' 'CONST SUPPORT 10/22/97 IF-AC1II i l ISI S2 !H- 1 97-0030 j MT NAD FEEDWATER LO0P 'A' SIESMIC RESTRAINT 10/22/97 lF-A4C3.20
._ ._ _. _. . _ _ . _ . .. __._..___-._____.__.4- -
e , _ _ _ . . _ _ . _ _ _ . . _ _ .
FEEf%f TG LOOP 'A' jr10E - ELBOW 10/22/97 ; C 5. 51 & HELB I
.!SI- LIB :W- 6 LS D 20 97-0032 ; MT NAD MAIN GTIf.:4 'A' (Se ELBOW - PIPE 10/22/97 l C 5. 50 IGI- 51t iW-12 N13033 I45' ~ ~ ~ ~ ~EAi -
MAIN STEAM 'A' {P!FE-FLANGE 10/22/97 1 C 5. BD I
ISI- $1C lW-13 LS U 97-0034 MT RAD MAIN ST!%M 'A' jPIFE - CAP 10/22/97 C 5. 50
. .. _ _ . . . . . . . . ~ - . . _. .
MA!N STEAM 'A' (PIPE-CAP 10/22/97 {C5.50 i
ISI- tec th-18 LS U 497-0036 UT45 NAD ,
MAINSTEAM 'B' P!PE - CAP l10/22/97 C 5. 50 i
15!- i[% h- 2 .97-0037 '. 7 3 NA; CHARGIN3 LINE *B' i lCBPE) 10/23/97 F-A C; I
'~ ~
XH 1-115 / 1'193 U rt h xture 57A0038" ' MT ' SP ~
Lift Rig Irternals .Rx Internals 10/23/97 Nateg 0612 NC Liriea r , i ndi cat ian , __
AH 3-1189 / 1190 ._ Lift Faxture 97-003eR1._ . _ . _ . . . MT NAD Litt Big Internals kx Internals 10/25/97 Nareg 061' N2
_ - Repair, Page 2 03/10/20
p------.____
e ,
hantie Island Fuclear Generatang Inservice Inspection Report Log Northern States Power Company 1717 Wakonada Drave Third Interval By Report # 414 Nicollet Hall Welch, >W 55009 Comunercial Service Date December 16, 1973 Minneapolis, tad 55401 220 itse Report Number Method Results System item Description Exam Date ASME Section XI Item IS!- 68C H- 1 97-0039 MT [NAD MAINSTEAM 'B' DEAR'G BRAK ASSY 10/23/97 T-A 6 C 3. 20 l i
Limited, Less than 904
_# 4 _ 'NAD 131- 51C H- 1 91-0040 MT SUFPORT BPAK ASSY 10/23/97 T-A 6 C 3, 20 MAIN STEAM 'A' LimReduleas than 901 W-11 97-0041 PT NAD 151-103 SI TEST PETUPN FIPE - VALVE 10/23/97 C 5. 30
~131- 99A W-12 97-0042 PT lNAD SI 12 DISCHARGE FLANGE - PIPE 10/21/97 C 5. 21 l TS3553~ H- 1 97-0043 (Al VT3 ;NAD SI TEST 9ETURN ROD /CIAMP 10/23/97 r+A Cl II
- I di- 4 3A W- A 97-0044 (A) UT60 lNAD STEAM GENERATOR fil TUBE SHEET / HEAD 10/23/97 5 2. 40 91-0045 VT3 'NAD ISI- BN H- 7 kHR OUMP 'B' DISCH P!GID HANGER / CLAMP 10/24/97 T-A C1 II W-29 91-0046 PT NAD 131- 89B RHS FUMP 'D' DISCH PIFE - 55s ELBOW 10/24/97 C 5. 11 ISI- 09A W-21 97-0047 PT jNAD PHR PUMP "A" DI$CH VALVE - PIPE 10/24/97 C 5. 11 I
.--._ . _._ -s __
..ISI- 09A W-22 i97-0048 i PT 1 NAD pHk PUHF "A" LISC}t FIPE - ELBOW f C 5.11 '
4 ___
l10/24/91 NAD ISI-. _ . . . . -IF ._.__ _ _ lW- 5 )97-0049 lPT i B 9, 21 l CHABGING LINE 'B' l4Se ELBOW - FIFE {10/24/97 '
l ! i y - -
ISI- IF l W. 6 97-0050 l FT lNAD CHARGING LINE 'B' lPITE - 45a ELBOW 10/24/97 : B 9. 21
_ M._ - . . . _ . _
. . . _ _iW-_2 ISI- 52 j97-0051 i UT45 NAD FEFDWATEP IfoP 'A' l P! rE - ELBOW l10/24/97 f C 5. 9 L 4 HELB I : _~ ._, . _
_ . _ . - - . _ m.._.
97-0052 , UT45 , NAD IS!- 69 tW-25 IN 93-20 FEEDWATER LOOP 'B' jPEDUCER - NOIZLE 10/24/97 l NO IN 93-20
.. - - . . _ _ - y.
IEEDWATER LOOP 'B' REDUCEB - NOZ2.LE 10/24/97 i NC IN 93-20 i
.._-_._.h.. _ + .- 4__..__.,.._.___..._ ._,
VT3 IND_.__
101- 34 lH-8A l97-0054 (A)
FC TUMP 12 CCLUMN TCP 4 FIN 9 2 l10/25/97 F-A C1 I
- Segport in contact with pump l i l
97-0054'R U A ' NkD ISI- 34' H- BA RC FUMP 12 PIN 9 2 111/05/97 T-A C1 I
,. COLUMN TOP & ;
_.___..-.4......... . . _ _ - .._ L_ __ E"U""f1"7. evaluation _ _
ISI- 99A. . - _ , . i W- 2 i97-0055 FT NA:
I 51 11 CISCHARGE fREDUCER-FIFE f10/05/97 C 5. 21 I
W-21 97-0056 UT45 dr ~
f ISI- 09A NHR P"MP "A" O!Scu l VALVE - FIFE I l0/25/97 0 11 ISI- 695 'Wl:2 '97-N57 *45 m BHR PUMP "A" DISCH FIFE - ELBOW 10/25/97 C' 11 W
.31- u9b .W-29 97-0250._ _ . . _ . . "!45 RHb FtHP 'B' DISCH FITE - She ELDOW 10/05/97 C 5. 11 III- 14
~~
bi *h?-005N .'
- 3 W B C Ft'MP 11 TIE BACK 9 1 10/25/97 T-A 6 B12 20 Page 3 03/10/00
I e
1 P sirie Island Wuclear Generating Inservice Inspection Report Log Northern States Power Company 1717 Wakonada Drive Third Interval By Report 0 414 Nicollet Hall WelcA ped 55089 Commercial Service Dates December 16, 1973 Minneapolis, tes 55401 ISO Item Report Number Method Results System item Description Exas Date ASME section XI Item H- 1A 97-00E0 VT3 ; NAD ISI- 14 PC FUMP 11 TIE BACK DCLT 9 1 10/25/97 F-A C1 I i
IS!- 14 H IB 91-0061 VT3 jNAD M FUMP 11 TIE BACK PIN 8 1 10/25/97 F-A C1 !
31-14 H- 4 97-0062 VT3 iNAD I
PC PUMP 11 PAD 1 10/25/97 F-A C1 I I
!$1- 14 H- 7 97-0063 VT3 .NAD RC PUMP 11 CONNECTION 9 1 10/25/97 F-A C1 I i
W ISI 14 H- 7A 97-0064 VT3 iNAD PC PUMP 11 COLUMN TOP & PIN 9 1 10/25/97 F-A C1 I
. . _ _IS!- 14 H- SA 97-0065 (A) VT3 jNAD RC PUMP 11 COLUMN TCP & PIN 9 2 10/25/97 F-A C1 I i l
~51-14 1 H- 5 97-0066 (Al VT3 NAD RC PUMP 11 PAD 2 10/25/*7 ?-A C1 I
'Is!- 34 H. 1 97-0067 (A) VT3 NAD TIE BACK 91 10/25/97 F-A & B10, 20 RC PUMP 12 H- 3 97-006B VT3 *NAD 31$ 34~
HC FUMP 12 TIE BACK 9 3 10/25/97 r-A & BIO. 20 131- 34 H- 3A 97-0069 VT3 NAD PC PtHP 12 TIE BACK BOLT 93 10/25/97 F-A C1 I s
- . - . . . - . . _ - - . . - . _s.
RC PUMP 12 TIE BACM PIN 93 10/25/97 ' F-A C1 1 RC PUMP 12 l RAD 3 10/25/97 lF-AC1I RC PUHF 12 jCONNECTION 9 3 10/25/97 T-A C1 1
-- . ..~. - - - . . - - - - ..
RC PUMP 1* !"OLUMN TCP & FIN 9 3 ! 10/25/97 1 F-A C1 1 l
PC PUHF 12 i BASE 9 3 f10/25/97 . r-A C1 I
! l I I
PC PUMP 12 COLUMN BOT & PIN 9 3 l10/25/97 F-A C1 I
. - . . _ . - _ _ _--- _ _-- - -----~. _ .
- TRANSITION - SHELL f10/25/97 C 1. 10 STEAM GENERATOR 512 fTRANSITICA-SHEL l10/25/97 C 1. 10 STEAN GENERATOR til
. . . . _ _ . . _ . . . . . . _ . . . - - - . - - . _ . . I. . - - - _ - _ _ _ - . _ _ _
t10/27/97 F-A & C 3. 20 TEEt> WATER LocP *A* ;SIE3MIC BESTRAINT
' i
. Leese nut and gap _ _ ___
97-0076R1 VT3 'C,_
ISI- 52 ) H- 1 FLEDWATE.R Lor r
- A' ,51ECMIC REETRAINT 11/06/97 F-A & C 3. N Pecrk ar.d Er:ginee rir.g
!sI- 43A. .
W- H (A). . . . .
- - . .. . . . _ .97-0379. UT2 STLAM Gua!'RATOR #11 TOP HEAD - SMELL '10/27/97 C 1, 20
^ ~
7-Od50'[AI nab 13I+ 43A ~W- H U*45 CTF.AM GENERATOR all I
TCP HEAD - SHELL l10/27/t.7 C1 20
- u Page 4 03/10/C8
e ,
Prairie Island Nuclear Generating Inservice Inspection Report Log Northern States Power Company 1717 wakonade Drive Third Interval By Report # 414 Nicollet Mall Welch,944 55089 Connercial Service Dates December 16, 1973 Minneapolis, >ti 55401 180 Item Report Number Method Results System f tee Description F.zam Date ASME Section XT ftem ISI- 4 3A W- N UT60 ;NAD l97-0001 (A) ;
STEAM GENEPATOR 911 \10/27/97 l C 1. 20 lTOPHrAD-SHELL l l
'97-0002 VT3 .NAD
~II-I 21 H- 1 '
3" RTD PETUPN LOCP B RUP'T PESTRAINT 10/27/97 F-A C1 I i i
ICI- 27A B- 2 97-0003 Vil iNAD EEAL INJ LOOP B' BOLTS 10/27/97 B7 50 l 1
'W- 9 97-0084 PT !NAD ISI- 27A i I:EAL INJ LOOP 'B' PIPE - FIANGE 10/27/97 B 9. 21 l t.
-._2 ISI- H- 3 97-0085 (A) l PT jNAD ACCUM. DISCHARGE 'A' GPPING 10/27/97 ' F-A & B10. 10 l I IR1I_0?2ff._?.x am
, H. 6 iNAD
_ _ . _ _JSI- 51A l97-0066 (A) l MT MAIN DTLAM 'A' BEAR'G BILAX AC0Y 0). 10/05/97 ; F-A & C 3, 20 3
' Limited, Less than 90% !
~II-I $1A H. S 97-0087 (A) MT NAD MAIN STEAM 'A' BEAR'G BRAK ASSY (3) 10/25/97 F-A & C 3. 20 Limited, Less than 90%
IND ISI- 2 H- 3 97-0086 (A) VT3 ACCUM. DISCHARGE 'A' SFRING 10/28/97 ; F-A & B10. 10 ;
l Follow-upexam, concrete l spall,ing uload settinq !
3 j97 0098R1 (A) , VT 3 i NAD ISI- 2 jH-ACCUM. DISCHARGE 'A' l11/06/97 [F-A&B10. 10 l' SPRING I En g pyring_y_yaluation
'97-0089 VT3 . NAD
!$1- 26 H- 1 2* CVC5 LITDOWN b' HYDR ENVBBER 10/28/97 F-A C1 I
- . . _ . 4...- .- -._---.-_4-.--~-.._.-__----_._-.--._--.
-. -.m 97-0090 VT3 NAD
.ISI- 26_ . . _ , . . .H- 3 2" CVCS LET[EWN B' l SPRING HANGER /CIAMP 10/28/97 r-A C1 I 97-0091 (A) VT3 .NAD IS!- 26 iH- 8 2" CYC0 LETD0WN B' {HY0R SNUBBER / CLAMP 10/29/97 F-A C1 I
- - , . - . . . - - ..-----_a----.-.----..-.-..~..--....._....--
MT NAD ISI- 43B. . - . . - . .- ;N- 1 IN-IR ; 9h0092 NO IN 93-20 STE/+1 GENERATOR #12 lrEEDWATER NCZZLE {10/29/97 FT NAD ISI- 'iA W-l l97-0093 GPRAY TO FRESSUH1ZER ; E LBow - P!f E (10/28/97 8 9. 21 l.
IS!- 43B 'N- 1 RING TEc i97-0094 V!3 NAD STf>W GENERATOR al fTVPINGTEE/S"FPORTS (10/28/97 NC IN 93-20 i
~
VT1 NA 151 - 4 n (W- F VT i95-0095 STEAM GENEKATok #12 ;TRAN3 WELD INT VT 110/28/97 NO IN 93-20 GTEAM GENE,RATOR all
- TOP SYPPORT GIRDER 10/28/97 F-A C1 I
)-
l
ISI- SIB ! 97-0097 MAIN STEAM *A' 4!e ELBDW - I'IPE !10/29/97 C 5. 50 97-0098 UT2 NAD 121- 41 W- S r p E S3t!RI;EP ~ TOP HEAD / SHELL 10/29/97 P2 11 lim ! e d, Enceeds 90%
W- L 97-0099 UT45 SA?
121- 41 PRE 00"kI2ER TCP FEAD / SHELL 10/29/97 92 11 L a i t e d, Exceeds 9?t 97-01h0 Pie 2
~
131- 41 wk
- i'P ES SURIZI:R T0F FEAD / SHELL 10/29/97 B2 13
~
Limitet Exceeds uC%
ISI- 14 h- 4 97-0101 ... ~
HC PUMP 11 LOWER SEAL HOUSIN3 10/29/97 9' (0
" or aer.ts ir thre m Fage 5 03/10/98
e- .
Pretrie Island Nuclear Generating Inservice Inspection Report Log Northern States Power Company 1711 Wakonede Drive Third Interval By Report 9 414 Nicollet Hall Welch, MH SS089 Commercial Service Dates December 16, 1973 Minneapolis, MN 55401 280 Item Report Number Me thod Results System item Description Eram Date ASME Section XI Item 151- 14 B- 4 97-0101P1 VT1 iNAD RC PUMP 11 LOWER SEAL HOUSING 11/05/97 8 7. 60 l E29LL'eriDg evaluation IS!- 14 B- 3 97-0102 VT1 IND RC PUMP 11 UPPER SEAL HOUSING 10/29/97 8 7. 60 i Deformed socket head I
'IS!- 14 B- 3 97-0102R1 VT1 ~ NAD DC PUMP 11 UPPER SEAL HOUSING 11/05/97 97. 60 Regiaced bolt ISI- 10 H- 2 97-0103 (A) VT3 jIND DPN lGN CROSSOVER) A DBLE SPRING / BENT BAR 10/30/97 F-A C1 I l Loose nut i 1S'l-
~
10 H- 2 97-0103R1 (A) VT3 IND DRN (ON CROSSOVER) A DBLE SPRING / BENT BAR 11/06/97 r-A C1 I Rework, bent rod 131- 10 H- 2 97-0103R2 (A) VT3 NAD DRN (ON CROSSOVER) A DBLE SFRING/ BENT EAR 11/07/97 T-A C1 I En_gineering evaluation '
!st- 11C H- 3 97-0104 (A) VT3 NAD SEAL INJ LOOP 'A' ROD CLAMP 10/30/97 F-A C1 1 ISI- 6 W- 6 97-0105 PT NAD RTD PETURN 'A' PIPE - ELBOW 10/30/97 8 9. 21 l'I2 S ~~i B- 1 97-0106 VT1 lNAD RTD RETURN 'A' i BOLTS FLANGE 10/30/97 B7 50
~~~ l 'NAD 3S57 ' 5' ~~ W-22 97-0107 PT RTD TAFE OFF 'A' HOT PIPE - ELBDW 10/30/97 8 9. 21
' PUMP 812 97-0100BL PT ;NAD ISI- 34 RC PUMP 12 FLYWHEEL KEYWAY a BORE 10/30/97 TS 4.2-1 ISt- 34 97-0109 UTO lNAD l PUMP #12 10/30/97 TS 4.2-1 PC PUMP 12 FLYWHEEL iKEYWAY 6 DOFE i
ICI- 34 PUMP #12 97-0110 UTO NAD RC FUMP 12 FLYWHEEL BODY 10/30/97 !TS4.2-1 ISI- 34 ~~~~~
- PUMP #12 ~' 9'7-0111 UTO .NAD RC PUMP 12 FLYWHEEL PERIPHERY :10/30/97 i TS 4.2-1 I i
- m. , 1 ISta 98A 'W- 2 97-0112 UT45 NAD SI 11 DISCKARGE REDUCER - PIPE 10/30/97 j C 5. 21 151- 99A
^'~
W-1R 97-0113 i UT45 NAD _
SI 12 DIFCRARGE FLANGE - PIPE ;10/30/97 i C 5. 21 I
~
IS!- 5}B H- 3 97-0114 Ei " AD HAIN STEAM 'A' SPRING HANGER 10/31/97 , F-A C1 11 RTO RETURN 'A' ;FIPE - FLANGE 11/01/97 ! B 9, 21 I Linear indications ISI- 6 l W- 4 ; 97-0115R1 ' PT NAD RTD kETCRN 'A' PIFE - FLANGE f11/21/97 B 9. 21
' E0.ginee r.ing ._eva l u a t i on
. . . . . . _ _ . . . _[.
ts!- 4e.. W- 1 '97-0116 FT NAD RCS OF.AINDOWN PIPE - NO*2LE 11/01/97 B 9. 31 ISI- 992 i H- 1 ?97-0111 VT3 NAD SI 11 DISCHARGE [DOX SUFFORT 11/01/97 F-A C1 II 1
'W-11 '97-0119 PT NAD ISI- 9eB SI 11 DISCHARGE .ELDOW - PIFE [11/01/97 C 5. 21 Page 6 03/10/99
Prai.rie Island Nuclear Gerarating inservice Inspection Report Log Northern States Power Company 1717 Wakonede Drive Third Interval By Report # 414 Nicollet Mall Waleth, >98 55089 Commercial Service Dates December 16, 1973 Minneapolis, tel 55401 130 Item Report Number Method Results Syatom item Description Eram Date ASME section XT Item W- 7 97-0119 j NA0 IS(- 26 lPT 2 C"/CS LETDOW84 'D' VALVE - PIFE 11/01/97 8 9. 21
_ . _ . ~ . _ _ . _ _ _ . _ _ _4___
W-11 97-0120 UT45 ' NAD 131- 9&B El 11 DISCHARGE ELBOW - PIFE 11/01/97 C 5. 21 121- 31 H2 91-0121 (A) VT3 :.NAD PRESSURIZER PELIEF PUPTURE PESTRAINT 11/03/97 F-A C1 I !
t ISI- 40 VESSEL INTR 97-0122 VT3 ! NAD REACTOR VESSEL VT INTL SURFACES 11/03/97 B13. 10 {
This report will not be j credited as 2nd period exam.'
~ ~ ~ ~
W- 6 97-0123 MT : NAD IS!- 49 R.V, CLOSUkE HEAD HEAD - FLANGE 11/03/97 B 1. 4 0 i
._ _ ._. .. 4 1S1- 49A W-04 97-0124 PT lNAD i
BV Top Head CRD-04 Nousing Weld 11/03/97 B14, 10 f
W-26 97-0125 PT NAD 131- 49A PV Tcp Head CRD-26 Housing Weld 11/03/97 B14. 10 NAD ISI- IC H- 1 97-0126 VT3 CHARGING !.INE 'B' ANCHOP 11/04/97 F-A C1 I f
- . ~ . - . - .
97-0127 i, NAD 3B W- 5 PT ISI-PHR LOOP 'A'
! FIPE 11/04/97 8 9. 11 l45eELBOW-
~
Limited exceeds 90%
MT NAD iGI U 60 W-11 397-0128 MAIN 3 TEAM 'B' i PITE - FIANGE NOZZLE 111/05/97 , C 5, 80
. I i
~
97-0129 FT NAD ISI- IC ' jW- 1 CHARGING LINE 'B' jFirE - TEE 111/05/97 i B 9, 21 I l 97-0130 PT NAD IS!- 53C ,W- 5 LS 2U D RHR SUCTION FUMP 'A' F. EDUCING TEE - PIFE l11/05/97 l C 5. 10 4
)
ISI- 53C W- 4 LS U 20 j97-0131 PT NAD l RHR CUCTION PUMP 'A' lPFDUCER - PED. TEE I
ll/05/97 C 5. 10 t
l . . . . . . _ . ~ . _
W-10 97-0132 1 PT .NAD l ISI- 19B !
8* PHR TAKE OFF 'B' lELB0W - PIPE !11/05/97 i B 9. 11 ted,, Exceeds __j01. _ __,___ _
B" PHR TAFE OFF 'b' 3 El. BOW - PIFE 11/05/97 B 9. 11
~
W- 5 ~~ ~5 9 0"l'37 UT45' ~ " NAD 151- 3a PHR LOOP 'A' 145a ELBOW - FIFE 111/04/97 8 9. 11
! t 2
.. ... ~ ..-._. - ._ -_-_... -_+ .
NAD
,W- 5 LS 2U D l97-0135 l UT45.
ISI- 53C. . . . . -
iREDUCING TEE - Fire l 11/05 / 97 C 5. 10 RHR SUCTION Pt'MP ' A' i i
~ ~~
97-0136 i~UT5 ~ ~EAD ISI- 53C lW- 4 LS U 2D PHR OUCTION PUMP 'A' (REDUCER - PED. Th.E 11/05/97 C 5. 10 l
97-0137BL VT3 NAD ISI- SA 'H- 4 SPRAY TD PRESSURIZER HYDR SN'!BBER/CLAMF 11/13/97 F-A C1 I MAD H. 1A -. - . . . .97-0139 'C ?
351- 44 RECEN HEAT EXCKANGEP FLOokSTAND 11/06/97 F-A J1 !
,97-0139 VT1 NAD ISI- 1H H- 4 CHAHGING LINE 'B' LATERAL BESTRAINT 4 11/06/97 F-A C1 I
'C 3 NAD
!$I- 53C H- 1 ;97-0140 ANCHOk ISTRUT) .11/06/97 F-A 1 II kHR SUCTION PUMP 'A' rage 7 03/10/98 _ - ._ ___-___ ___________________-
e ,
Prairie Island Huclear Generating Inoervice Inspection Report Log Northern States Power Company 1717 wakonede Drive Third Interval By Report 0 414 Nicollet Hall Welch, MN 55009 Comunercial Service Date: December 16, 1973 Minneapolis, MN 55401 ISO Item Report Number Method Results System Item Description Exam Date ASME Section XI Item 97-0141 VTJ ,NAD IS!* 690 lH- 1 MAINSTEAM 'B' !BEAP'G Bn.AM ASSY 10/20/97 ; F-A & C 3. 20 I l 4
. - . . . . . . - . . . _ . . - . . _ . _ __ a 131- 41 W- 3 97-0142 UT60 NAD FRE55URIZEk BOTTOM HEAD / SHELL 11/06/97 B 2. 11 I
Limited, Exceeds 90%
ISI- 41 W- 3 97-0143 UT45 {NAD PRESSURIZER BOTTOM HEAD / SHELL 11/06/97 B 2. 11 .
d imited d xceeds 90%
ISI- 41. . _ _ _ . W- 3 97-0144 UTO ;NAD FRESOUP1ZER BOTTOM HEAD / SHELL 11/06/97 B 2. 11 l LimitednExceeds 904 ISI- 34 B- 3 97-0145 VT1 : NAD RC PUMP 12 LOWER SEA 1. HOUSING 11/01/97 B7 60 l
97-0146 VT1 i NAD 151- 34 B- 4 RC FUMP 12 UFPER SEAL HOUSING 11/07/97 B7 60
-s
--131- 27B H- 2 97-0147 VT3 NAD CLAL INJ LOOP 'B' ANCHOR 11/07/97 F-A C1 I 1S1- ei W- 1 97-0146 UT45 !NAD P!PE - N0ZZLE 11/15/97 B 9. 31 RCS DRAINDOWN {
ISI- 34 B- 1 97-0149 UTO i NAD R PUMP 12 PUMP F1M CE BOLTS 11/01/97 B 6.180 l
R.V, NUTS 97-015V HT . NAD ISI- 37 PEACTOR VECCEL NUTS 11/07/97 B 6. 10 t
Limited, B2.54 ISI- 37 !R.V. WSHRS 197-0151 t VT1 NAD REfCTOR VE30EL 11/07/97 B 6. 50 lWASHEks
__._.4.._....___. _.--_d..._.-_..--__.-. UT45 NAD
[F1- 52 W-23 j97-0152 (A)
FEEDWATEF IIrP 'A' REDUCER - NOZZLE 11/08/97 i C 5. 51
.o..__ GEO j97-0153 (A) UT60 131- 52 jW-23 C 5. 51 l FtELWATEk Loor 'A' 1 REDUCER - NOZZLE 1 11/09/97 i
i _ _ _,I NAO l 131- 37 !R.V. STUDS 197-0154 MT PEACTOR VECSE' STUCS {11/10/97 , B 6. 30
. _ _ _97-0155 , UTO NAD 151- 37 iR.V. STUN i REACTCR vi.SSEL STUDS !11/10/97 {B6.30
, I
-_.J.-.-..-- -- s - - . . - - .. - - - - - . .. -
W-10 i97-0156 ! P !' . - - - - - - . . ~ . .NAD ISI- 5A !
SPRAY TO PRESSURIZER ! EE.DUCING TEE - FIFE 11/1C/97 ' B 9. 21 j i
97-0157 UT(0 GE3 St. n>A :W-le SI 12 IISCHARGE ' F1.ANGr - FI PE
.10/30/97 C 5. 21 l
UT60 OED 151- 96A :W- 2 j97-0159 1 REDUCE 0 - PIPE i10/30/97 . C 5. 21
$1 11 DISCHARGE
_-.--$.......--.---_.--..O -.. 4 - . - - - - - - - - - - ~ ~ - - - - - - -
+97-0159 MT NAD xW-1-194. Rx Head Lugs Nareg 0612 NC Ex Nead I..lft Lugs [Rx Head f11/16/97 ,
~
~
~ ^ i.~ o 0 ((0~~ '/T 3 " nA .
7 p ; . 4' y. n.;1A STEAM GENEMTCH wi' CCLUMN T N 4 FIN 1 . 11/16.9' F-A Cl W- B 9'-01t 1 UTO MA Is!- 439 STr>M GENERATOR 61. TITE $hEET - SHELL 11/19/97 01 30
~
NA0
~
07-01h2 UT45
~
- I- 433 W. B STEAM GEhrRATD8 #12 TUBESHEET - ShELL 11/19.' 9 C 1. 30
_, Limited. . D:ceeas 40%
Page 8 03/10/99
4 * ,
Prairie Island Nuclear Generating Inservice Inspection Report Log Northern States Power Company 1717 wakonada Drive Third Interval By Report # 414 Nicollet Mall Welch, MN 55099 - Commercial service Datet December 16, 1973 Minneapolis, MN 55401 ISO Item Report Number Method Results System ites Description Exas Date ASME Section XI Item 101- 432 W- B 97-0163 UT60 l NAD STEAM GENEPATOR 912 TUBECHEET - SHELL 11/19/97 C 1. 30 Limited, Exceeds 90%
181- 43B W- A 97-0164 UTO j NAD STEAM GENERATOR 812 TUBE SHEET / HEAD 11/15/97 2 2. 40 Limited, Exceeds 90%
ISI- 4)B W- A 97-0165 UT45 NAD STEAM GENERATOR #12 TUBE SHEET / HEAD 11/11/97 8 2. 40 Limited, Exceeds 90%
TSI-52 H- 6 97-0166 MT 'NAD FEEDWATER LOOP 'A' ANCHOR ELBOW 11/20/97 F-A s C 3. 20
'iSt-52 H- 6 97-0167 VT3 lNAD FEEDWATER LOOP 'A' ANCHOR ELBOW 11/20/97 F-A & C 3. 20 Is!- 52 W-12 97-0168 MT
]NAD FEEDWATER LOOP ' A' ELBOW - PIPE 15/20/97 C 5. 51 l H5 97-0169 VT3 NAD
~ISI-52 RESTRAINT 11/20/97 F-A & C 3, 20 TEEDWATER 1.00F 'A' T51- 39 MARMON CLAMF 97-0110 VT1 NAD R.V. CONOCEAL BLTING MAPMON CIAMP 11/18/97 B 7. 10 ISI- 43B W- A 97-0171 UT60 )NAD STEAM GENERATOR 612 TUBE SHEET / HEAD 11/10/97 B 2. 40 i Limiteda Exceeds 90% {
W- 6 97-0172 UTO NAD ISI- 49 R.V. CLOG"RE HEAD HEAD - FIhlGE 11/12/97 B 1. 40 Limited, Less than 90% !
151- 49 W- 6 97-0173 l Uf4T lNAD R,V. CLOSUPE HEAD NEAD - FLANGE 11/11/91 B 1. 40 1 Limited, Less than 90%
_ _ _ _ _ . _ _ . . h #
IND 131- 52 H- 5 t97-0174 i MT !
FEEDWATER LOOP ' A' RF3T#AINT fil/20/97 lF-A6C3.20
- } npar indications.
1 I
FF.EDWATE R LOOP ' A' lRESTPAINT l 11/25/ 97 lF-A&C3.20OTTE.(gg evalpation _
. _ - _ _ . _ _ ~ . . .
l R.V. CLOSUkE HEAD HEAD - FLANGE 11/10/97
- B 1. 40 t31,_}p_ss_tha, Q 4 FEE 0 WATER LOOP 'A' , ELBOW - PIPE 11/21/97 C 5. 51 I ~
i H- 1 97-0177 PT ;IND 131- 938 RHR HEAT EXCH 12 SUFFORT 11/24/97 F-A & C 3. 10 Li1L.arj ndication _ _ . _ _ _ _ _ .
' PT NAD 151- 930 lH- 1 l97-0177P1 RHR HEAT EXCN 12 jsurPORT l 12 / 01/ 97 F-A 6 C 3. 10
! i Repair
__.1_ ___ IND ISI- 43C IH-17 97-0178 jVT3 STEAM GENEPATOR #11 BUMPE9 BLOCK 11/25/97 l F-A C1 I
! Lack of thread engagement
_ . _ . . . . ~ _ _ _ _ .
151- 43C ! 6f-17
[97-017eR1 j
i VT3 NAD
- 11/26/97 F-A C1 I STEAM GENERATOR #11 !DUMTER BLOCK
.I... i -- - - --~~ En gi ny _Mya l qa yop ,_,NAD H - -
...____.____m j 97-0179 (A) ; VT3 ISt- %
DOUBLE SN"BBER/CLAMF '11/25/97 T-A C1 I CIRAY TO PhESSURIZEk i
- 97-0180 PT Z g3g- 17 .W- 7 12" ACC"MULATOR CSCH IRED. TEE - VALVE I11/25/97 8 9. 11 i IN 97-10, OEA 1997074 197-0181 ' VT3 nab IS!- er ;H-240
' COLUMN BCT & PIN 9 4 F-A C1 1 CTEAM GENERATOR #11 {11/25/97
, . ,-_.... n - . _ . - _
Page 9 03/10/C8'
a * ,
Prairie Island Nuclear Generating Inservice Inspection Report Log Northern States Power Company 1717 Wakonado Drive Third Interval By Report # 414 Nicollet Hall welch, MH 55089 Commercial service Date: December 16, 1973 Minneapolis, H4 55401 ISO Item Paport Number Method Resulta System item Description Exam Date ASME Section XI ftem IST- 43C 97-0182 VT3 ;NAD lH-29 STEAM GENERATOR 811 BASE 9 4 11/25/97 F-A C1 I g
STEAM GE.NERATOP 911 PAD 11/25/97 F-A C1 1
(
ISI- 43C H-16 '97-0104 VT3 lNAD STEAM GENERATOR #11 PAD 11/25/97 r-A C1 1 l 1
_ISI- 2 W. 5 97-0185 PT NAD ACCUM. DISCHARGE 'A' ELBOW - VALVE 11/25/97 8 9. 11 1 IN 97-19 d EA 1997074 L
__151- 51C W-17 LS U 97-0186 (Al MT l NAD MAIN STEAM 'A' PIPE - CAP 11/26/97 C 5. 50 1 l
ISI- 69C W-12 Ls 0 97-0187 (Al MT I NAD MAINSTEAM 'B' PIFE - CAP 11/26/97 C 5. 50 l l
IS!- 2 W- 5 97-0188 UT45 NAD ACCUM. DISCHARGE 'A' ELDOW - VALVE 11/25/97 8 9. 11 IN 97-19, OEA 1997074 ISI- 17 W- 7 97-0189 UT45 NAD 12" ACCUMULATOR DSCH PED. TEE - VALVE 11/25/97 8 9. 11 IN 97-19, OEA1997074, Limited, Exceeds 90%
ISI- 2 W- 5 97-0190 (Al UT60 l NAD ACCUM. DISCHAPOE 'A' ELBOW - VALVE 11/25/97 8 v. 11
_ .L _ . I N__97 -19, __OEA 1997074
. - . . . . . .Is!- 17 . . . _ . _ . . . . lW- 7 97-0191 (A) ! UT60 NAD 12" ACCUM'7LATOR DSCH [ RED. TEE-VALVE 11/25/97 lB9. 11 I IN 97-19, OLA 1997074
~
3gj- 3'bA
~
V- 1 197-0192 ;NAD lVT3 PEACTOk VESSEL SIS A ; VALVE INT SURFACES l10/26/97 j B12. 50 1 <
Page 10 03/10/m
NORTHERN STATES POWER
SUMMARY
REPORT INSERVICE INSPECTION PRAIRIE ISLAND UNIT 1,1997 APPENDIX D LIST OF SECTION XI VT-2 EXAMINATIONS 1 Page l
l 1
l
ISI PRESSURE TEST PROGRAM Summary Description of inservice Pressure tests performed on Prairie Island Unit 1, Piping Systems per various Surveillance procedures as indicated below. All pressure tests were satisfactory.
SYSTEM CLASS DESCRIPTION PROCEDURE DATE RESULTS RC 1 REACTOR COOLANT 1070 12/11/97 SAT VC 2 CVCS 1168.16 8/28/96 SAT FW 2 FEEDWATER 1168.17 7/17/96 SAT BA 2 BORIC ACID 1168.21 3/13/97 SAT l
l
NORTHERN STATES POWER
SUMMARY
REPORT INSERVICE INSPECTION PRAIRIE ISLAND UNIT 1,1997 APPENDIX E RESULTS OF STEAM GENERATOR EDDY CURRENT EXAMINATIONS 56 Pages l
L
~ '
NbRTHERN STATES POWER
SUMMARY
REPORT INSERVICE INSPECTION PRAIRIE ISLAND UNIT #1,1997 RESULTS OF STEAM GENERATOR EDDY CURRENT EXAMINATIONS 10/97 REFUEL OUTAGE l
During the Odober 1997 scheduled refueling outage,100% of all accessible tubes in steam generators 11 and 12 were examined full length as part of the inservice inspection. The examination was conducted utilizing the multifrequency eddy current technique. The inspection program was as follows:
- 1. Bobbin Coil Examinations - The bobbin coil technique was used to examine all tubes full length, except the U-Bend region of rows 1 and 2 and the sleeved portion of sleeved tubes. These bobbin coil examinations were completed using magnetically biased 0.720 inch and 0.700 inch diameter probes.
- 2. MRPC Examinations - The 0.680 inch dual motion Plus Point MRPC technique was used to examine the U-Bend region of rows 1 and 2. The 0.720 inch 3-Coil (0.115' mid range pancake / Plus Point mid range / 0.080* high frequency shielded pancake) MRPC technique was used to examine; 100% of the hot leg tubes from 3 inches (steam generator 11) and 6 inches (steam generator 12) above the seconary tube sheet face through the tube end and 20% of the cold leg tubes from 1 inch above the secondary tube sheet face through the tube end. The 0.610 inch Gimbated Plus Point MRPC technique was used to examine the entire sleeve (from sleeve end to sleeve end) on all inservice l
sleeves, except for three sleeves which were obstructed, not tested and subsequently plugged.
- 3. Supplemental Examinations - The 0.680 inch dual motion Plus Point MRPC technique was used to examine all free span dents > 5.0 volts located in the U-Bend region of the tube. The 0.720 inch and 0.620 inch (sleeved tubes) 3-Coil MRPC technique was used to supplement the bobbin coil data to further characterize all: absolute drift signals, copper deposit signals, other deposit signals, dent signals
> 5.0 volts in the straight section of tubing, indications not reportable > 1.5 volts at tube support plates, manufacturing bumish mark signals, mix residual indication signals, possible loose part signals, possible support ligament Indication signals, non quantifiable indication signals, distorted indication signals and cold leg thinning indications greater than 40% through wall. The 0.720 inch magnetically biased 3-Coil MRPC technique was used to disposition MRPC indications of tube noise, possible loose (
parts and permeability variations. The 0.730 inch combination probe (bobbin / 0.115' mid range .l pancake / Plus Point mid range) was used to profile; all inservice rerolls using January 1996 data, all successful preservice (new) rerolls and also used on one tube to verify the presence of cold leg thinning. The 0.620 inch 3-coil (0.115' pancake / 0.110' axial / 0.110" circ.) and the 0.610 inch magnetically biased Gimbated Plus Point MRPC techniques were utilized to further characterize sleeve weld zone indications.
- 4. Pre-Service Baseline Examinations - The 0.610 inch Gimbaled Plus Point MRPC technique was used to examine the entire sleeve (from sleeve end to sleeve end) on allinstalled sleeves. The 0.610 inch magnetically biased Gimbated Plus Point MRPC technique was utilized on three sleeves with excessive permeability variations.
- 5. Asiditional Research Examinations - In addition to the normal Steam Generator ISI examination, several new prototype probes were utilized on in situ tubes and tube pull candidates. Data was collected using three array probes; the MICA" probe developed by NDT Engineering Corp., the surface riding plus point array probe (SRAP) probe developed by Zetec Inc. and the CECCO-Sm probe developed by Westinghouse Canada Inc. and one non surface riding rotating plus point probe developed by Zetec inc..
l 1
~
NORTHERN STATES POWER
SUMMARY
REPORT INSERVICE INSPECTION PRAIRIE ISLAND UNIT #1,1997 Rockridge Technologies, Inc. was contracted to acquire and evaluate the eddy current data. Zetec, Inc.
was contracted to perform a completely independent evaluation of all data acquired by Rockridge utilizing manual analysis on all MRPC data and Computer Data Screening (CDS) on all bobbin coil data. The scope of all the work contracted was completed using remote positioning devices and the Zetec MlZ-30 digital test equipment along with ACQUIRE PROGRAM proto 4F dated 9/4/97. The analysis was completed using Zetec, Inc. EDDYNET95 version 4.0 including Patch _E95_4.17 with MlZ-30 ANALYSIS proto 4G dated 8/25/97, RPC PROGRAM proto 4F dated 8/25/97, CDS PROGRAM proto 3B dated 6/28/97, COMPARE proto 2B dated 6/21/97 and BOBBIN PROFILE rev. 3 dated 1/5/97.
A summary of the distribution of Indications can be found in Table I and cumulative lists for each category are listed on page 19 and attached.
A summary of the distribution of indication disposition can be found in Table ll.
Lists of: tubes left inservice without any additional reroll (F*0), tubes successfully rerolled at the lower elevation (NEW F*1), tubes left inservice with a prior cycle reroll (OLD F*1), tubes sleeved and tubes plugged can be found in Tables !!I through Vil respectively.
A summary of the total tubes plugged to date (1197) and total tubes sleeved to date (1197) can be found in Tables Vill and IX respectively.
TABLEI DISTRIBUTION OF INDICATIONS S/G NO. 0-19% 20-29% 30- 39% 40-100% CODES 11 43 74 34 11 180 12 20 23 4 1 346 CODES INCLUDE: mal, MCI, sal. SCI. SVI & VOL TABLE 11 DISTRIBUTION OF INDICATION DISPOSITION S/G NO. 40 - 50 % F*0 F*1 SLEEVE PLUG j 11 10 113 6 0 54 12 0 0 6 222 119 40-50%: tubes left inservice - old AVB wear below Tech. Spec. Limit 2 !
i
NdRTHERN STATES POWER
SUMMARY
REPORT INSERVICE INSPECTION PRAIRIE ISLAND UNIT #1,1997 TABLE lll TUBES LEFT INSERVICE WITHOUT ANY ADDITIONAL REROLL (F*0)
S/G N O. LEG ROW COL PERCENT LOCATION STATUS 11 H 2 14 SAI TRH - 2.7TO- 2.5 F*0 11 H 3 14 SAI TRH - 2.7TO- 2.6 F*0 11 H 1 15 SAI TRH - 2.8TO- 2.7 F*0 11 H 2 17 sal TRH - 2.9TO- 2.8 F*0 11 H 3 21 mal TRH - 3.0TO- 2.9 F*O 11 H 1 25 MAI TRH - 2.8TO- 2.6 F*O 11 H 4 25 MAI TRH - 2.7TO- 2.5 F*0 11 H 5 25 MAI TRH - 2.6TO- 2.5 F*0 11 H 10 25 sal TRH - 2.6TO- 2.5 F*0 11 H 20 25 sal TRH - 2.6TO- 2.5 F*O 11 H 1 27 MAI TRH - 2.8TO- 2.5 F*0 11 H 6 27 sal TRH - 2.7TO- 2.6 F*0 11 H 1 28 sal TRH - 2.8TO- 2.6 F*O 11 H 1 29 mal TRH - 2.9TO- 2.8 F*0 11 H 5 29 SAI TRH - 2.7TO- 2.5 F*O 11 H 19 29 MAI TRH - 2.5TO- 2.4 F*0 11 H 20 29 SAI TRH - 2.6TO- 2.5 F*0 11 H 1 30 SAI TRH - 2.7TO- 2.6 F*0 11 H 5 30 SAI TRH - 2.6TO- 2.5 F*0 11 H 7 30 SAI TRH - 2.7TO- 2.5 F*0 11 H 9 30 sal TRH - 2.8TO- 2.7 F*0 11 H 13 30 sal TRH - 2.8TO- 2.7 F*0 11 H 14 30 sal TRH - 2.6TO- 2.5 F*0 11 H 19 30 MAI TRH - 2.8TO- 2.7 F*0 11 H 20 30 sal TRH - 2.5TO- 2.5 F*0 11 H 21 30 sal TRH - 2.6TO- 2.6 F*0 11 H 1 31 SAI TRH - 2.6TO- 2.5 F*0 11 H 5 31 SAI TRH - 2.5TO- 2.4 F'O 11 H 7 31 mal TRH - 2.5TO- 2.5 F*0 11 H 9 31 MAI TRH - 2.6TO- 2.6 F*0 11 H 10 31 SAI TRH - 2.7TO- 2.6 F*0 11 H 13 31 sal TRH - 2.6TO- 2.5 F*0 11 H 15 31 MAI TRH - 2.5TO- 2.4 F*0 11 H 19 31 MAI TRH - 2.6TO- 2.5 F*0 11 H 21 31 SAI TRH - 2.6TO- 2.5 F*0 11 H 1 32 MAI TRH - 3.0TO- 2.8 F*0 11 H 6 32 SAI TRH - 2.6TO- 2.6 F*0 l 11 H 13 32 sal TRH - 2.6TO- 2.5 F*0 11 H 2 33 sal TRH - 2.5TO- 2.5 F*0 11 H 12 33 SAI TRH - 2.6TO- 2.6 F*0 11 H 14 33 MAI TRH - 2.7TO- 2.6 F*0 11 H 18 33 SAI TRH - 2.6TO- 2.5 F*0 11 H 19 33 sal TRH - 2.8TO- 2.7 F*0 3
L
NdRTHERN STATES POWER
SUMMARY
REPORT INSERVICE INSPECTION PRAIRIE ISLAND UNIT #1,1997 l TABLE 111 CONTINUED TUBES LEFT INSERVICE WITHOUT ANY ADDITIONAL REROLL (F*0)
S/G NO. LEG ROW COL PERCENT LOCATION STATUS 11 H 1 34 sal TRH - 2.8TO- 2.7 F*0 11 H 6 34 SAI TRH - 2.5TO- 2.4 F*0 11 H 9 34 SAI TRH - 2.7TO- 2.6 F*O 11 H 10 34 SAI TRH - 2.5TO- 2.4 F'O 11 H 13 34 sal TRH - 2.6TO- 2.5 F*0 11 H 14 34 SAI TRH - 2.6TO- 2.5 F*0 11 H 1 35 SAI TRH - 2.8TO- 2.7 F*O 11 H 2 35 sal TRH - 2.6TO- 2.5 F*O 11 H 15 35 SAI TRH - 2.4TO- 2.4 F*0 11 H 1 36 MAI TRH - 3.1TO- 2.9 F*0 11 H 13 36 MAI TRH - 2.7TO- 2.6 F*0 11 H 16 36 MAI TRH - 2.5TO- 2.4 F*0 11 H 21 36 SAI TRH - 2.6TO- 2.5 F*0 11 H 2 37 MAI TRH - 3.0TO- 2.9 F*O 11 H 9 37 sal TRH - 2.9TO- 2.8 F*0 11 H 14 37 MAI TRH - 2.9TO- 2.8 F*0 11 H 16 37 MAI TRH - 2.6TO- 2.4 F*0 11 H 1 38 SAI TRH - 2.6TO- 2.5 F*0 11 H 8 38 MAI TRH - 2.6TO- 2.5 F*O 11 H 13 38 sal 1RH - 2.7TO- 2.7 F*0 11 H 14 38 sal TRH - 2.9TO- 2.8 F*0 11 H 16 38 SAI TRH - 2.7TO- 2.7 F*0 11 H 22 38 sal TRH - 2.8TO- 2.7 F*0 11 H 1 -39 MAI TRH - 2.6TO- 2.5 F*0 11 H 2 39 SAI TRH - 2.6TO- 2.5 F*0 11 H 7 39 sal TRH - 2.5TO- 2.4 F*0 11 H 20 39 SAI TRH - 2.8TO- 2.7 F*0 11 H 22 39 sal TRH - 2.9TO- 2.8 F*0 !
11 H 35 39 sal TRH - 2.6TO- 2.5 F*0 11 H 1 40 mal TRH - 2.6TO- 2.5 F*0 11 H 4 40 SAI TRH - 2.5TO- 2.4 F*0 11 H 22 40 sal TRH - 2.5TO- 2.4 F*0 11 H 1 41 SAI TRH - 2.6TO- 2.5 F*0 11 H 4 41 SAI TRH - 2.8TO- 2.7 F*0 j 11 H 18 41 sal TRH - 2.7TO- 2.7 F*0 '
11 H 20 41 sal TRH - 2.9TO- 2.8 F*0 11 H 20 42 SAI TRH - 2.9TO- 2.8 F*0 11 H 21 42 sal TRH - 2.4TO- 2.3 F*0 11 H 1 43 sal TRH - 2.6TO- 2.5 F*0 11 H 17 43 MAI TRH - 2.5TO- 2.4 F*0 11 H 22 43 SAI TRH - 2.6TO- 2.5 F*0 11 H 1 44 SAI TRH - 2.7TO- 2.6 F*0 11 H 10 44 sal TRH - 2.6TO- 2.5 F*0 4
l I NdRTHERN STATES POWER
SUMMARY
REPORT INSERVICE INSPECTION PRAIRIE ISLAND UNIT #1,1997 TABLE Ill CONTINUED TUBES LEFT INSERVICE WITHOUT ANY ADDITIONAL REROLL (F*0)
S/G NO. LEG ROW COL PERCENT LOCATION STATUS 11 H 17 44 SAI TRH - 2.7TO- 2.6 F*0 11 H 19 44 sal TRH - 2.5TO- 2.4 F*0 11 H 21 44 sal TRH - 2.5TO- 2.4 F*0 11 H 22 44 SAI TRH - 2.6TO- 2.5 F*0 11 H 1 45 sal TRH - 2.5TO- 2.6 F*0 11 H 6 45 SAI TRH - 2.4 TO- 2.6 F*0 11 H 19 45 mal TRH - 2.6TO- 2.5 F*0 11 H 21 46 MAI TRH - 2.8TO- 2.7 F*0 11 H 1 48 sal TRH - 2.8TO- 2.9 F"O 11 H 2 49 SAI TRH - 2.7TO- 2.6 F*0 11 H 1 50 mal TRH - 2.7TO- 2.6 F*0 11 H 1 51 SAI TRH - 2.6TO- 2.5 F*0 l 11 H 1 54 MAI TRH - 2.6TO- 2.5 F*0 11 H 1 55 SAI TRH - 2.6TO- 2.4 F*0 11 H 5 55 MAI TRH - 2.5TO- 2.4 F*O 11 H 1 56 SAI TRH - 2.5TO- 2.5 F*0 11 H 1 58 sal TRH - 2.7TO- 2.8 F*O 11 H 1 59 sal TRH - 2.9TO 2.8 F*0 11 H 19 60 MAI TRH - 2.5TO- 2.3 F*0 11 H 12 63 sal TRH - 2.6TO- 2.5 F*0 11 H 1 68 SAI TRH - 2.8TO- 2.9 F*O 11 H 1 70 MAI TRH - 2.7TO- 2.6 F*0 11 H 1 72 SAI TRH - 2.8TO- 2.8 F*0 11 H 1 73 SAI TRH - 2.8TO- 2.7 F*0 11 H 1 76 sal TRH - 2.8TO- 2.7 F*0 11 H 1 78 SAI TRH - 2.8TO- 2.5 F*0 11 H 1 87 sal TRH - 2.7TO- 2.5 F*0 TABLE IV TUBES SUCCESSFULLY REROLLED AT LOVER ELEVATION (NEW F*1)
S/G NO. LEG ROW COL PERCENT LOCATION STATUS 11 H 8 27 sal TRH - 0.1TO+ 0.1 F'1 11 H 30 46 SAI TRH - 0.0TO+ 0.1 F*1 11 H 5 57 SAI TRH - 0.1TO+ 0.1 F*1 12 H 31 46 sal TRH + 0.1TO+ 0.3 F*1 sal 1BH - 1.2TO- 1.1 F*1 12 H 31 47 mal TRH + 0.1TO+ 0.1 F*1 12 H 32 47 MAI TRH + 0.1TO+ 0.2 F'1 f
l 5
' NdRTHERN STATES POWER -
SUMMARY
REPORT ,
INSERVICE INSPECTION PRAIRIE ISLAND UNIT #1,1997 I
l- TABLE V I TUBES LEFT INSERVICE WITH A PRIOR CYCLE REROLL (OLD F*1)
S/G NO. LEG ROW COL PERCENT LOCATION STATUS 11 H 23 17 sal 1BH - 2.1TO- 1.8 F*1 l MAI 1BH - 2.9TO- 2.4 F*1 l 11 H 5 56 sal 1BH - 1.4TO- 1.3 F*1 11 H 8 78 MAI 1BH - 2.9TO- 2.2 F*1 '
12 H 34 31 mal 1BH - 1.2TO- 1.1 F*1 l 12 H 37 38 MAI 1BH - 1.3TO- 1.1 F*1 12 H 4 71 MAI 1BH - 1.6TO- 1.2 F*1 TABLE VI TUBES SLEEVED S/G NO. LEG ROW COL PERCENT LOCATION STATUS 12 H 5 6 SAI TRH + 0.5TO+ 9.1 SLV 12 H 6 6 mal TRH + 3.6TO+ 7.5 SLV 12 H 4 7 MAI TRH + 0.3TO+ 8.8 SLV 12 H 6 7 sal TRH + 0.6TO+ 5.2 SLV 12 H 9 7 MAI TRH + 0.5TO+ 10.8 SLVQ 12 H 2 8 sal TRH + 6.1TO+ 8.5 SLV 12 H 4 8 mal TRH + 0.4TO+ 10.5 SLVQ 12 H 6 8 MAI TRH + 0.4TO+ 4.0 SLV 12 H 9 8 MAI TRH + 0.4TO+ 9.0 SLV 12 H 9 9 mal TRH + 0.4TO+ 10.9 SLVQ 12 H 5 11 SAI TRH + 0.4TO+ 8.8 SLV 12 H 14 11 - sal TRH + 0.1TO+ 0.1 SLV 12 H 16 12 MAI TRH + 0.6TO+ 9.8 SLVQ 12 H 8 13 SAI TRH + 6.9TO+ 7.5 SLV 12 H 21 13 mal TRH + 0.5TO+ 9.1 SLV 12 H 13 14 MAI TRH + 0.4TO+ 10.5 SLVQ 12 H 17 15 sal TRH + 0.1TO+ 0.2 SLV 12 H 6 16 MAI TRH + 0.1TO+ 0.2 SLV l- 12 H 20 16 SAI TRH + 0.0TO+ 0.1 SLV 12 H 5 19 SAI TRH + 1.9TO+ 3.1 SLV 12 H 23 19 SAI TRH + 0.1TO+ 0.1 SLV@
12 H 3 21 mal TRH + 0.1TO+ 0.2 SLV ;
l 12 H 14 21 MAI TRH - 0.2TO+ 0.2 SLVQ )
l MAI TRH + 1.6TO+ 2.5 SLV@
12 H 16 21 MAI TRH + 0.1TO+ 0.2 SLV l 12 H 23 21 SAI TRH + 0.2TO+ 0.3 SLV@
I 12 H 24 21 MAI TRH + 0.1TO+ 0.2 SLV@
12 H 6 23 SAI TRH + 0.2TO+ 0.2 SLV 12 H 13 23 SAI TRH + 0.1TO+ 0.2 SLV SAI TRH + 9.1TO+ 9.6 SLV 12 H 16 23 MAI TRH + 0.1TO+ 0.2 SLV .
1 2
6
NORTHERN STATES POWER
SUMMARY
REPORT INSERVICE INSPECTION PRAIRIE ISLAND UNIT #1,1997 I
l TABLE VI CONTINUED ,
TUBES SLEEVED S/G NO. LEG ROW COL PERCENT LOCATION STATUS {
12 H 19 23 SAI TRH + 0.1TO+ 0.2 SLV 12 H 23 23 SAI TRH + 0.1TO+ 0.2 SLV@
12 H 15 26 sal TRH + 0.2TO+ 0.3 SLV 12 H 21 26 MAI TRH + 0.2TO+ 0.3 SLV@
12 H 23 26 SAI TRH + 0.2TO+ 0.3 SLV@
12 H 27 26 sal TRH + 0.1TO+ 0.1 SLV 1 SLV@ !
MAI 1BH - 1.0TO+ 2.1 12 H 4 27 SAI TRH + 0.1TO+ 0.2 SLV 12 H 12 27 sal TRH - 0.1TO+ 0.2 SLV 12 H 6 28 sal TRH + 0.5TO+ 2.4 SLV 12 H 11 28 sal TRH + 0.1TO+ 0.1 SLV 12 H 2 29 sal TRH - 0.0TO+ 0.2 SLV 12 H 5 29 sal TRH - 0.0TO+ 0.2 SLV sal TRH + 1.3TO+ 2.3 SLV 12 H 11 29 MAI TRH + 0.1TO+ 0.2 SLV 12 H 12 29 sal TRH + 0.1TO+ 0.1 SLV 12 H 29 29 mal TRH - 0.0TO+ 0.1 SLV mal 1BH - 0.9TO+ 2.2 SLV@
12 H 6 30 sal TRH + 0.1TO+ 0.2 SLV 12 H 9 30 sal TRH + 0.1TO+ 0.2 SLV 12 H 22 30 sal TRH + 0.1TO+ 0.1 SLV@
12 H 34 30 sal TRH + 0.0TO+ 0.2 SLV@
12 H 21 31 sal TRH + 0.1TO+ 0.2 SLV@
12 H 4 32 MAI TRH + 0.2TO+ 0.2 SLV 12 H 8 32 mal TRH + 0.1TO+ 0.2 SLV 12 H 10 32 sal TRH + 0.2TO+ 0.2 SLV 12 H 11 32 VOL TRH + 0.2TO+ 3.0 SLV@ (
MAI TRH + 2.5TO+ 4.6 SLV@
12 H 12 32 sal TRH + 0.2TO+ 0.2 SLV 12 H 14 32 sal TRH + 0.1TO+ 0.2 SLV 12 H 24 32 VOL TRH + 3.5TO+ 3.7 SLVQ VOL TRH + 4.6TO+ 4.8 SLVQ MAI TRH + 3.1TO+ 5.9 SLV@
12 H 5 33 MAI TRH + 0.1TO+ 0.3 SLV 12 H 8 34 SAI TRH + 0.5TO+ 1.0 SLV 12 H 15 34 sal TRH + 0.1TO+ 0.2 SLV SAI TRH + 6.9TO+ 11.1 SLV
! SAI TSH + 0.8TO+ 1.1 SLV 12 H 21 34 MAI TRH + 2.5TO+ 4.9 SLV sal TRH + 8.4TO+ 9.8 SLV j 12 H 23 34 MAI TRH + 0.0TO+ 0.2 SLV@
12 H 4 35 mal TRH + 0.1TO+ 0.3 SLV 12 H 15 35 SAI TRH + 0.1TO+ 0.2 SLV 4 7
L_____________-_______________________
' ' NdRTHERN STATES POWER
SUMMARY
REPORT INSERVICE INSPECTION PRAIRIE ISLAND UNIT #1,1997 TABLE VI CONTINUED TUBES SLEEVED S/G NO. LEG ROW COL PERCENT LOCATION STATUS 12 H 26 35 mal TRH + 0.1TO+ 0.2 SLV@
12 H 28 35 MAI TRH + 0.1TO+ 0.2 SLV MAI 1BH - 0.7TO+ 2.1 SLV@
12 H 2 37 SAI TRH + 0.2TO+ 0.2 SLV ,
12 H 26 38 MAI TRH + 0.1TO+ 0.2 SLV@
12 H 29 39 MAI TRH + 0.1TO+ 0.2 SLV mal 1BH - 0.9TO+ 2.2 SLV@ l 12 H 33 39 sal TRH + 0.2TO+ 0.2 SLV MAI 1BH - 0.9TO+ 2.1 SLV@
12 H 21 40 mal TRH + 0.1TO+ 0.1 SLV@ ;
12 H 27 40 MAI TRH + 0.1TO+ 0.2 SLV MAI 1BH - 1.6TO+ 1.8 SLV@ ;
12 H 34 42 mal TRH + 0.1TO+ 0.2 SLV ___
MAI 1BH - 0.3TO+ 1.4 SLV@
12 H 15 43 SAI TSH + 0.3TO+ 0.4 SLV 12 H 33 44 mal TRH + 0.1TO+ 0.2 SLV MAI 1BH - 0.8TO+ 2.0 SLV@
12 H 9 45 MAI TRH + 0.0TO+ 0.1 SLV 12 H 16 45 SAI TRH + 0.1TO+ 0.2 SLV 12 H 12 46 SAI TRH + 0.2TO+ 0.3 SLV 12 H 17 46 sal TRH + 3.4TO+ '3.9 SLV 12 H 26 46 MAI TRH + 0.1TO+ 0.2 SLV@
12 H 34 46 sal TRH + 0.1TO+ 0.2 SLV MAI 1BH - 0.3TO+ 2.1 SLV@
12 H 36 46 mal TRH + 0.1TO+ 0.2 SLV mal 1BH + 1.2TO+ 1.9 SLV@
12 H 3 47 mal TRH + 3.2TO+ 5.0 SLV 12 H 11 47 mal TRH + 0.1TO+ 0.2 SLV j sal TRH + 4.0TO+ 4.2 SLV sal TRH + 6.0TO+ 6.2 SLV 12 H 15 47 SAI TSH + 0.4TO+ 0.8 SLV 12 H 21 47 SAI TSH + 0.6TO+ 0.7 SLV 12 H 22 47 SAI TSH + 0.2TO+ 0.5 SLV 12 H 24 47 SAI TRH + 4.3TO+ 9.2 SLV@
12 H 27 47 sal TRH + 0.0TO+ 0.1 SLV@
MAI TRH + 3.3TO+ 5.9 SLV@
12 H 9 48 SAI TRH + 0.1TO+ 0.2 SLV 12 H 16 48 mal TRH + 0.1TO+ 0.2 SLV 12 H 3 49 sal TRH + 0.1TO+ 0.2 SLV i 12 H 10 49 MAI TRH + 1.8TO+ 3.8 SLV 12 H 20 49 sal TRH + 0.1TO+ 0.2 SLV f mal TRH + 0.1TO+ 0.3 SLV I 12 H 34 49 MAI 1BH - 0.7TO+ 1.9 SLV@
8
I NdRTHERN STATES POWER
SUMMARY
REPORT INSERVICE INSPECTION PRAIRIE ISLAND UNIT #1,1997 TABLE VI CONTINUED TUBES SLEEVED S/G NO. LEG ROW COL PERCENT LOCATION STATUS 12 H 16 50 sal TRH + 0.1TO+ 0.2 SLV sal TSH + 0.4TO+ 0.6 SLV 12 H 24 50 SAI TRH + 0.1TO+ 0.2 SLV@
12 H 28 50 sal TRH + 2.1TO+ 7.0 SLV 12 H 14 51 SAI TRH + 0.1TO+ 0.1 SLV mal TSH + 0.1TO+ 0.4 SLV 12 H 16 51 MAI TRH + 0.1TO+ 0.2 SLV@
MAI TRH + 2.7TO+ 0.3 SLV@
SAI TRH + 9.0TO+ 9.9 SLV@
12 H 17 51 MAI TRH + 0.1TO+ 0.2 SLV 12 H 25 51 sal TRH + 3.1TO+ 3.5 SLV 12 H 33 51 SAI TRH + 0.1TO+ 0.1 SLV MAI 1BH - 0.8TO+ 2.2 SLV@
12 H 5 52 sal TRH + 3.4TO+ 3.5 SLV SAI TRH + 4.1TO+ 4.3 SLV sal TRH + 4.7TO+ 4.8 SLV 12 H 8 52 sal TRH + 0.1TO+ 0.2 SLV 12 H 15 52 SAI TRH + 0.0TO+ 0.1 SLV 12 H 22 52 mal TRH + 0.1TO+ 0.2 SLV@
12 H 14 53 sal TRH + 0.1TO+ 0.2 SLV 12 H 16 53 mal TRH + 0.1TO+ 0.2 SLV 12 H 20 53 mal TRH + 0.1TO+ 0.2 SLV 12 H 21 53 mal TRH + 0.1TO+ 0.2 SLV@
12 H 23 53 sal TRH + 0.1TO+ 0.2 SLV@ ;
12 H 27 53 MAI TRH + 0.1TO+ 0.2 SLV l MAI 1BH - 0.8TO+ 2.0 SLV@ '
12 H 29 53 mal TRH + 0.1TO+ 0.2 SLV MAI 1BH - 1.2TO+ 1.9 SLV@
12 H 4 54 MAI TRH + 0.1TO+ 0.2 SLV 12 H 14 54 sal TRH + 6.6TO+ 7.7 SLV i 12 H 32 54 MAI TRH + 0.1TO+ 0.2 SLV MAI 1BH - 0.7TO+ 1.9 SLV@
12 H 5 55 MAI TRH - 0.0TO+ 0.1 SLV 12 H 16 55 MAI TRH + 0.1TO+ 0.2 SLV 12 H 28 55 mal TRH + 0.1 TO+ 0.2 SLV mal 1BH - 0.6TO+ 2.0 SLV@
12 H 12 56 SAI TRH + 0.1TO+ 0.2 SLV ,
12 H 16 56 MAI TRH + 0.1TO+ 0.2 SLV 12 H 31 56 MAI TRH + 0.1TO+ 0.2 SLV MAI 1BH + 0.2TO+ 2.1 SLV@
12 H 3 57 SAI TRH + 0.1TO+ 0.2 SLV 12 H 6 57 SAI TRH + 0.1TO+ 0.1 SLV SAI TRH + 1.7TO+ 2.7 SLV 9
w_______.
NdRTHERN STATES POWER
SUMMARY
REPORT INSERVICE INSPECTION PRAIRIE ISLAND UNIT #1,1997 TABLE VI CONTINUED TUBES SLEEVED S/G NO. LEG ROW COL PERCENT LOCATION STATUS l 12 H 19 57 mal TRH + 0.1TO+ 0.2 SLV 12 H 20 57 sal TRH + 0.1TO+ 0.2 SLV 12 H 32 57 MAI TRH + 0.1TO+ 0.2 SLV MAI 1BH + 0.8TO+ 1.6 SLV@
12 H 37 57 sal TRH + 0.1TO+ 0.2 SLV MAI 1BH + 0.0TO+ 1.4 SLV@
12 H 14 58 MAI TRH + 0.1TO+ 0.2 SLV 12 H 2 59 SAI TRH + 4.3TO+ 5.1 SLV 12 H 13 59 sal TRH + 0.6TO+ 5.4 SLV 12 H 14 59 MAI TRH + 0.1TO+ 0.2 SLV 12 H 20 59 sal TRH + 0.1TO+ 0.2 SLV 12 H 24 59 MAI TRH + 0.1TO+ 0.3 SLV@
12 H 29 59 MAI TRH + 0.1TO+ 0.2 SLV MAI 1BH - 0.7TO+ 2.0 SLV@
12 H 9 60 mal TRH + 0.1TO+ 0.2 SLV 12 H 10 60 MAI TRH + 0.8TO+ 2.7 SLV 12 H 25 60 SAI TRH + 0.1 TO+ 0.2 SLV@
12 H 9 61 sal TRH + 0.1TO+ 0.2 SLV 12 H 11 61 mal TRH + 0.5TO+ 8.1 SLV 12 H 16 61 MAI TRH + 0.1TO+ 0.2 SLV 12 H 9 62 sal TRH + 0.0TO+ 0.1 SLV sal TRH + 0.8TO+ 5.8 SLV 12 H 10 62 MAI TRH + 0.6TO+ 5.1 SLV 12 H 12 62 MAI TRH + 1.1TO+ 6.9 SLV 12 H 14 62 SAI TRH + 4.2TO+ 8.7 SLV 12 H 33 62 MAI TRH + 0.2TO+ 0.3 SLV MAI 1BH - 0.8TO+ 2.1 SLV@
12 H 2 63 sal TRH + 0.2TO+ 0.3 SLV SAI TRH + 1.5TO+ 1.8 SLV 12 H 15 63 sal TRH - 0.1TO+ 0.1 SLV 12 H 23 63 mal TRH + 0.0TO+ 0.2 SLV@ l 12 H 32 63 sal TRH + 0.1TO+ 0.1 SLV MAI 1BH - 0.8TO+ 2.0 SLV@
12 H 36 63 VOL TSH + 0.0TO+ 0.2 SLV !
12 H 3 64 MAI TRH + 0.5TO+ 5.9 SLV ,
12 H 8 64 sal TRH + 0.1TO+ 0.1 SLV ;
12 H 13 64 mal TRH + 0.0TO+ 0.1 SLV l 12 H 19 64 mal TRH + 3.7TO+ 8.5 SLV
- 12 H 24 64 SAI TRH + 0.1TO+ 0.2 SLV@
l 12 H 25 64 MAI TRH - 0.0TO+ 0.1 SLV@
12 H 4 65 MAI TRH + 0.0TO+ 0.2 SLV I
12 H 6 65 MAI TRH + 0.0TO+ 0.2 SLV 12 H 8 65 MAI TRH + 1.7TO+ 2.2 SLV 10
I NbRTHERN STATES POWER
SUMMARY
REPORT INSERVICE INSPECTION PRAIRIE ISLAND UNIT #1,1997 l l
TABLE VI CONTINUED TUBES SLEEVED S/G NO. LEG ROW COL PERCENT LOCATION STATUS 12 H 15 65 mal TRH + 0.0TO+ 0.2 SLV j 12 H 19 65 SAI TRH + 5.5TO+ 6.0 SLV 12 H 7 66 sal TRH + 0.1TO+ 0.2 SLV _
12 H 8 66 mal TRH + 0.1TO+ 0.2 SLV 12 H 6 67 MAI TRH + 0.7TO+ 3.3 SLV 12 H 9 67 MAI TRH + 1.5TO+ 5.1 SLV 12 H 13 67 MAI TRH + 0.0TO+ 0.1 SLV VOL WCH + 0.2TO+ 0.3 SLV@
12 H 20 67 MAI TRH + 0.6TO+ 4.9 SLV 12 H 25 67 sal TRH + 0.1TO+ 0.2 SLV@
12 H 31 67 SAI TRH + 0.1TO+ 4.1 SLV 12 H 8 68 sal TRH + 0.1TO+ 0.2 SLV 12 H 12 68 SAI TRH + 0.0TO+ 0.2 SLVQ sal TRH + 1.1TO+ 12.4 SLVQ 12 H 23 68 MAI TRH + 0.1TO+ 0.2 SLV3 12 H 4 69 MAI TRH + 0.7TO+ 3.8 SLV 12 H 9 69 sal TRH + 0.1TO+ 0.1 SLV 12 H 14 70 MAI TRH + 0.1TO+ 0.2 SLV sal TRH + 4.6TO+ 4.7 SLV 12 H 15 70 MAI TRH + 0.1 TO+ 0.2 SLV 12 H 18 70 sal TRH + 0.1TO+ 0.2 SLV 12 H 23 70 mal TRH + 0.1TO+ 0.2 SLV@
12 H 10 71 SAI TRH + 0.1TO+ 0.2 SLV 12 H 4 72 MAI TRH - 0.2TO+ 0.3 SLVO 12 H 5 72 MAI TRH + 0.1TO+ 0.2 SLV i 12 H 8 72 sal TRH + 1.5TO+ 2.4 SLV !
12 H 10 72 SAI TRH + 0.1TO+ 0.3 SLV 12 H 15 72 mal TRH + 0.1TO+ 0.3 SLV 12 H 25 72 sal TRH + 0.6TO+ 5.7 SLV 12 H 5 73 MAI TRH + 0.1TO+ 0.2 SLV 12 H 12 73 SAI TRH + 0.7TO+ 7.4 SLV 12 H 16 73 SAI TRH + 4.9TO+ 5.0 SLV 12 H 17 73 SAI TRH + 1.4TO+ 2.0 SLV 12 H 26 73 SAI TRH + 1.8TO+ 2.0 SLV 12 H 2 74 sal TRH + 0.4TO+ 1.5 SLV 12 H 4 74 MAI TRH + 0.2TO+ 0.3 SLV 12 H 10 74 MAI TRH + 0.1TO+ 0.2 SLV
, 12 H 11 75 sal TRH - 0.0TO+ 0.0 SLV 12 H 13 75 SAI TRH + 1.6TO+ 3.4 SLV 12 H 15 75 MAI TRH + 0.1TO+ 0.2 SLV 12 H 6 76 MAI TRH + 0.1TO+ 0.2 SLV 12 H 8 76 SAI TRH + 0.5TO+ 3.7 SLV 12 H 9 76 mal TRH + 0.1TO+ 0.2 SLV 11 u_________________._.
' ' bRTHERN N STATES POWER
SUMMARY
REPORT INSERVICE INSPECTION PRAIRIE ISLAND UNIT #1,1997 t
l TABLE VI CONTINUED
! TUBES SLEEVED S/G NO. LEG ROW COL PERCENT LOCATION STATUS 12 H 19 76 SAI TRH + 7.2TO+ 12.2 SLVO 12 H 2 77 MAI TRH + 0.5TO+ 4.6 SLVQ 12 H 5 77 MAI TRH + 0.1TO+ 0.2 SLV 12 H 9 77 MAI TRH + 0.1TO+ 0.2 SLV 12 H 11 77 SAI TRH + 6.4TO+ 6.7 SLV 12 H 14 77 MAI TRH + 0.1TO+ 0.2 SLV 12 H 19 77 MAI TRH + 1.0TO+ 1.9 SLV 12 H 8 78 sal TRH + 3.4TO+ 3.9 SLV 12 H 5 79 SAI TRH + 0.0TO+ 0.1 SLV 12 H 7 79 sal TRH + 0.1TO+ 0.2 SLV 12 H 14 79 SAI TRH + 0.1TO+ 0.2 SLV 12 H 7 80 MAI TRH + 0.1TO+ 0.2 SLV 12 H 12 80 sal TRH + 0.1TO+ 0.2 SLV 12 H 17 80 sal TRH + 3.3TO+ 4.0 SLV 12 H 16 81 SAI TRH + 2.9TO+ 3.7 SLV 12 H 4 82 MAI TRH + 0.0TO+ 0.2 SLV 12 H 10 82 MAI TRH + 0.1TO+ 0.2 SLV 12 H 5 83 sal TRH + 0.1TO+ 0.1 SLV 12 H 9 83 SAI TRH + 0.0TO+ 0.1 SLV 12 H 10 84 MAI TRH + 0.1TO+ 0.2 SLV 12 H 17 84 SAI TRH + 2.0TO+ 2.5 SLV 12 H 11 85 MAI TRH + 0.1TO+ 0.2 SLV TABLE Vll TUBES PLUGGED S/G NO. LEG ROW COL PERCENT LOCATION STATUS 11 C 6 2 VOL TSC + 0.0TO+ 0.7 PLGQ 11 H 13 6 SVI 01H - 0.1TO+ 0.2 PLG 11 C 12 15 VOL TSC + 0.4TO+ 0.7 PLGQ 11 H 36 18 SVI 03H 0.0TO+ 0.3 PLG 11 H 27 20 VOL TSH - 0.0TO+ 0.2 PLGO l 11 H 27 21 VOL TSH - 0.1TO+ 0.1 PLG@ 1 11 H 37 21 SVI 03H - 0.1TO+ 0.2 PLG '
11 C 25 24 VOL TSC + 23.8TO+ 24.0 PLGO
, 11 C 42 32 36 01H + 2.4 PLG@
PLP 01H + 2.6 PLGO VOL 01H + 2.5TO+ 2.9 PLG@
11 H 43 34 SVI 03H + 0.2TO+ 0.4 PLG 11 H 44 36 SVI 03H + 0.0TO+ 0.3 PLG i
12 l
l l ' ' NdRTHERN STATES POWER
SUMMARY
REPORT
! INSERVICE INSPECTION PRAIRIE ISLAND UNIT #1,1997 TABLE Vil CONTINUED TUBES PLUGGED S/G NO. LEG ROW COL PERCENT LOCATION STATUS 11 C 45 37 59 03C + 0.0 PLG VOL 03C - 0.1TO+ 0.2 PLG SV1 01H + 0.2TO- 0.0 PLG SVI 03H + 0.3TO+ 0.1 PLG 11 H 35 38 SVI 01H + 0.2TO- 0.1 PLG 11 H 11 39 SVI 01H + 0.2TO+ 0.1 PLG 11 H 32 41 SVI 01H - 0.2TO+ 0.2 PLG@
11 H 9 42 sal TRH - 0.1TO- 0.0 PLG mal 1BH - 0.4TO+ 1.5 PLG@
11 H 4 43 sal TRH + 0.1TO+ 0.3 PLG mal 1BH - 0.6TO+ 2.0 PLG@
11 H 13 48 MAI TRH + 0.1TO+ 0.2 PLG MAI 1BH - 0.4TO+ 2.0 PLG@
11 H 12 50 SAI TRH + 0.2TO+ 0.2 PLG MAI 1BH - 0.5TO+ 1.0 PLG@
11 H 17 50 MAI TRH + 2.1TO+ 4.1 PLGO 11 C 44 50 VOL 01C - 0.1TO- 0.3 PLG 11 C 44 51 VOL 01C + 0.2TO- 0.3 PLG 11 C 30 53 DSI 06C - 0.2 PLG@
11 H 16 54 SVI 01H - 0.3TO 0.0 PLG 11 H 45 54 SVI 01H + 0.1TO+ 0.4 PLG 11 C 40 56 DSI 07C - 0.2 PLG@
11 H 8 58 SVI 02H - 0.3TO+ 0.2 PLG 11 H 12 62 SAI TRH + 0.1TO+ 0.3 PLG MAI 1BH - 0.2TO+ 1.4 PLG@
11 H 24 62 SVI 01H - 0.2TO+ 0.1 PLG 11 H 3 64 SAI TRH + 0.1TO+ 0.2 PLGQ SAI TRH + 1.0TO+ 2.8 PLGQ 11 H 24 64 SVI 01H - 0.1TO+ 0.2 PLG 11 H 43 64 SVI 01H + 0.1TO+ 0.3 PLG 11 H 25 65 VOL 06H + 44.1TO+ 44.6 PLGQ 11 H 4 66 SAI TRH - 0.0TO+ 0.1 PLG mal 1BH - 0.6TO+ 1.8 PLG@
11 H 5 69 SVI 02H - 0.3TO+ 0.3 PLG 11 C 37 72 VOL 02C + 0.3TO+ 0.0 PLG 11 H 11 74 SVI 01H - 0.1TO+ 0.1 PLG 11 C 34 74 VOL 01C - 0.1TO- 0.3 PLG 11 H 17 77 SAI TRH + 1.6TO+ 1.7 PLG 11 C 32 77 VOL 01C - 0.1TO- 0.3 PLG 11 C 32 78 VOL 01C + 0.2TO- 0.1 PLG 11 C 31 79 VOL 01C + 0.4TO+ 0.2 PLG 11 C 31 81 VOL 01C + 0.1TO- 0.2 PLG 11 C 23 84 VOL 01C + 0.1TO- 0.3 PLG 13
i
(
NbRTHERN STATES POWER
SUMMARY
REPORT y INSERVICE INSPECTION PRAIRIE ISLAND UNIT #1,1997 TABLE Vil CONTINUED TUBES PLUGGED S/G NO. LEG ROW COL PERCENT LOCATION STATUS 11 H 27 85 SVI 02H + 0.0TO+ 0.3 PLG 11 C 23 87 VOL 01C + 0.0TO- 0.4 PLG 11 C 18 89 VOL 01C + 0.3TO+ 0.2 PLG VOL 01C - 0.1TO- 0.3 PLG 11 C 20 89 VOL 01C - 0.3TO+ 0.1 PLG@
11 C 14 90 VOL 01C - 0.1TO- 0.3 PLG 11 H 16 90 SVI 01H + 0.1TO+ 0.3 PLG 11 H 14 91 SVI 01H + 0.2TO+ 0.4 PLG 11 C 7 92 VOL 02C - 0.1TO- 0.3 PLG 11 C 7 93 VOL 03C - 0.2TO- 0.4 PLG 11 H 9 93 SVI 01H + 0.0TO+ 0.4 PLC 12 H 3 3 MAI TRH + 9.9TO+ 12.7 PLG 12 H 8 4 sal TRH + 6.8TO+ 10.7 PLG 12 H 16 7 SAI TRH + 2.5TO+ 4.8 PLG 12 H 3 11 VOL WCH - 0.3TO+ 0.2 SLVPLG 12 H 19 11 sal 01H - 0.1TO+ 0.1 PLG@
sal 03H - 0.4TO- 0.2 PLG@
VOL 02H + 7.7TO+ 8.2 PLG@
sal TRH + 0.3TO+ 14.0 PLG@
12 H 8 16 VOL WCH - 0.2TO+ 0.1 SLVPLG 12 H 25 16 VOL WCH - 0.3TO+ 0.4 SLVPLG 12 H 13 17 MCI WCH - 0.2TO+ 0.3 SLVPLG 12 H 17 18 VOL WCH - 0.1TO+ 0.3 SLVPLG 12 H 17 22 VOL WCH - 0.2TO+ 0.4 SLVPLG 12 H 19 25 VOL WCH - 0.1TO+ 0.4 SLVPLG 12 H 37 27 VOL TSH - 0.1TO+ 0.1 PLG 12 H 4 28 VOL WCH + 0.0TO+ 0.3 SLVPLG !
12 H 13 28 MCI WCH - 0.1TO+ 0.4 SLVPLG l 12 H 27 29 SVI 03H - 0.1TO+ 0.2 PLG 12 H 17 31 VOL WCH - 0.2TO+ 0.3 SLVPLG 12 H 43 31 MAI 01H - 0.2TO+ 0.3 PLG ;
SVI 03H - 0.2TO+ 0.1 PLG 12 H 42 33 SV1 03H - 0.5TO- 0.2 PLG SVI 03H - 0.1TO+ 0.5 PLG 12 H 42 34 SVI 03H + 0.1TO+ 0.3 PLG sal 01H - 0.1TO+ 0.2 PLG 12 H 43 34 SVI 03H - 0.1TO+ 0.3 PLG 12 H 44 35 SVI 03H - 0.2TO+ 0.3 PLG 12 H 3 36 VOL WCH - 0.1TO+ 0.1 SLVPLG i 12 H 11 36 VOL WCH - 0.1TO+ 0.1 SLVPLG l
12 H 14 36 MCI WCH - 0.1TO+ 0.3 SLVPLG 12 H 15 36 MCI WCH - 0.2TO+ 0.3 SLVPLG I
14
l * ' NdRTHERN STATES POWER
SUMMARY
REPORT INSERVICE INSPECTION PRAIRIE ISLAND UNIT #1,1997 I
1 TABLE Vil CONTINUED TUBES PLUGGED 1
S/G NO. LEG ROW COL PERCENT LOCATION STATUS 12 H 3 37 OBS TEH + 13.0 SLVPLG DNT TEH + 13.0 SLVPLG 4 12 C 12 39 SVI 07C + 0.1TO+ 0.4 SLVPLG 12 H 13 40 VOL WCH - 0.3TO+ 0.2 SLVPLG 12 H 3 41 VOL WCH - 0.2TO+ 0.2 SLVPLG WCH - 0.2TO+ 0.3 12 H 8 41 VOL SLVPLG WCH - 0.1TO+ 0.2 SLVPLG 12 H 10 41 VOL 12 H 14 41 MAI TSH + 0.1TO+ 1.4 PLGQ sal TSH - 0.5TO- 0.3 PLG3 12 H 23 41 OBS TEH + 10.4 SLVPLG DNT TEH + 10.4 SLVPLG 12 H 4 43 VOL WCH - 0.2TO+ 0.2 SLVPLG 12 H 10 43 VOL WCH - 0.2TO+ 0.3 SLVPLG 12 H 16 43 VOL WCH - 0.1TO+ 0.4 SLVPLG 12 H 8 44 SVI 02H - 0.2TO+ 0.2 SLVPLG 12 H 13 44 SCI WCH - 0.1TO+ 0.1 SLVPLG 12 H 6 45 SCI WCH - 0.1TO+ 0.2 SLVPLG@
12 H 1 46 sal 07H + 3.7TO+ 4.0 PLGQ 12 H 3 46 VOL WCH - 0.1TO+ 0.2 SLVPLG 12 H 4 47 VOL WCH - 0.3TO+ 0.2 SLVPLG 12 H 42 47 sal TSH + 0.4TO+ 0.8 PLGQ 12 H 6 48 sal TRH + 0.1TO+ 0.2 SLVPLG@
12 H 8 48 VOL WCH - 0.2TO+ 0.3 SLVPLG3 12 H 17 48 MAI TSH + 0.0TO+ 1.0 PLGQ 12 H 42 48 VOL TSH + 0.5TO+ 0.8 PLGQ i
12 H 14 50 VOL WCH - 0.2TO+ 0.3 SLVPLG 12 C 45 50 VOL 01C + 0.1TO+ 0.4 PLG 12 H 21 51 VOL WCH - 0.2TO+ 0.3 SLVPLG 12 H 10 52 SCI WCH - 0.1TO+ 0.1 SLVPLG j 12 C 45 52 VOL 01C + 0.1TO+ 0.3 PLG 12 C 44 53 VOL 01C + 0.2TO+ 0.3 PLG 12 C 43 54 VOL 01C + 0.2TO+ 0.4 PLG 12 C 44 54 VOL 01C + 0.1TO+ 0.3 PLG 12 H 6 55 VOL WCH - 0.1TO+ 0.3 SLVPLG 12 H 12 55 VOL WCH - 0.2TO+ 0.3 SLVPLG 12 H 44 55 SVI 01H + 0.1TO+ 0.3 PLG 12 C 45 55 VOL 01C + 0.2TO+ 0.4 PLG 12 H 3 56 VOL WCH - 0.1TO+ 0.2 SLVPLG 12 C 44 56 VOL 01C + 0.1TO+ 0.3 PLG 12 H 45 56 SVI 02H - 0.1TO+ 0.4 PLG 12 H 4 57 OBS TEH + 9.2 SLVPLG I 12 H 8 57 VOL WCH - 0.3TO+ 0.2 SLVPLG 12 H 43 59 SVI 01H + 0.1TO+ 0.4 PLG 15
NORTHERN STATES POWER
SUMMARY
REPORT INSERVICE INSPECTION PRAIRIE ISLAND UNIT #1,1997 TABLE Vil CONTINUED TUBES PLUGGED S/G NO. LEG ROW COL PERCENT LOCATION STATUS 12 H 44 59 VOL TSH + 13.5TO+ 13.6 PLGQ SVI 01H + 0.2TO+ 0.3 PLG 12 H 44 60 SVI 01H + 0.2TO+ 0.3 PLG i 12 H 7 61 VOL WCH - 0.1TO+ 0.3 SLVPLG 12 H 41 61 VOL TSH + 0.1TO+ 0.2 PLG 12 C 42 61 47 01C + 0.3 PLG VOL 01C + 0.2TO+ 0.3 PLG 12 H 42 62 SVI 02H - 0.2TO+ 0.0 PLG 12 H 13 63 SCI WCH - 0.2TO+ 0.0 SLVPLG 12 H 16 64 VOL WCH - 0.3TO+ 0.2 SLVPLG 12 H 42 64 SVI 01H + 0.1TO+ 0.4 PLG 12 H 7 65 VOL WCH - 0.2TO+ 0.1 SLVPLG 12 H 17 65 VOL WCH - 0.2TO+ 0.1 SLVPLG l 12 H 1 66 mal TRH + 0.6TO+ 1.9 PLG 12 H 6 66 VOL WCH - 0.2TO+ 0.2 SLVPLG 12 H 23 67 VOL WCH - 0.3TO+ 0.1 SLVPLG@
12 C 38 67 VOL 01C + 0.2TO+ 0.5 PLG 12 C 40 67 VOL 01C + 0.1TO+ 0.5 PLG SVI 01H - 0.4TO- 0.1 PLG 12 H 7 68 VOL WCH - 0.2TO+ 0.3 SLVPLG@
12 C 37 70 VOL 01C + 0.1TO+ 0.5 PLG 12 H- 39 70 SVI 01H + 0.1TO+ 0.4 PLG 12 H 38 72 SVI '1 H + 0.1TO+ 0.3 PLG 12 H 33 74 sal TRH + 1.4TO+ 2.1 PLG 12 H 4 75 VOL WCH - 0.2TO+ 0.3 SLVPLG . j 12 C 35 75 VOL 01C + 0.2TO+ 0.5 PLG 12 H 36 75 SVI 03H + 0.0TO+ 0.3 PLG 12 H 23 76 SVI 03H - 0.1TO+ 0.2 PLG 12 H 32 76 SV1 03H - 0.1TO+ 0.2 PLG 12 H 33 76 SVI 03H - 0.1TO+ 0.3 PLG 12 H 34 76 SV1 03H - 0.0TO+ 0.3 PLG 12 H 35 76 SVI 02H - 0.0TO+ 0.3 PLG 12 C 26 77 VOL TSC - 0.1TO+ 0.3 PLG i 12 H 33 77 SVI 03H + 0.1TO+ 0.2 PLG 12 H 35 77 SVI 02H - 0.3TO+ 0.3 PLG 12 H 36 77 SVI 03H - 0.1TO+ 0.2 PLG 12 H 4 78 SCI WCH - 0.1TO+ 0.2 SLVPLG 12 C 26 78 VOL TSC - 0.1TO+ 0.2 PLGQ l 12 H 30 78 SVI 01H + 0.2TO+ 0.4 PLG SVI 03H + 0.1TO+ 0.4 PLG 12 H 32 79 SVI 02H - 0.1TO+ 0.3 PLG 12 H 33 79 SVI 03H - 0.0TO+ 0.3 PLG 12 H 3 80 VOL WCH - 0.2TO+ 0.3 SLVPLG l
16 1'
l
' NDRTHERN STATES POWER
SUMMARY
REPORT INSERVICE INSPECTION PRAIRIE ISLAND UNIT #1,1997 TABLE Vil CONTINUED TUBES PLUGGED l
S/G NO. LEG ROW COL PERCENT LOCATION STATUS 12 H 5 80 VOL WCH - 0.2TO+ 0.3 SLVPLG 12 C 26 81 SVI 06C - 0.0TO+ 0.1 PLG 12 H 18 89 SVI 01H - 0.2TO+ 0.2 PLG i
l 12 H 20 89 SVI 01H + 0.1TO+ 0.5 PLG 12 C 15 90 VOL 01C - 0.2TO+ 0.3 PLG SVI 01H - 0.2TO+ 0.2 PLG 12 H 16 90 SVi 01H + 0.1TO+ 0.4 PLG 12 C 18 90 VOL 01C - 0.2TO+ 0.1 PLG 12 C 12 91 VOL 01C - 0.0TO+ 0.2 PLG SV1 01H - 0.1TO+ 0.2 PLG l 12 H 15 91 SVI 01H + 0.1TO+ 0.3 PLG 12 H 16 91 SVI 02H - 0.1TO+ 0.3 PLG SVI 03H + 0.0TO+ 0.2 PLG 12 H 8 92 SVI 01H - 0.1TO+ 0.1 PLG l
12 H 10 92 SVI 01H - 0.2TO+ 0.2 PLG 12 H 13 92 SVI 01H - 0.3TO- 0.2 PLG I
12 H 8 93 SVI 01H - 0.2TO+ 0.1 PLG 12 H 9 93 SVI 01H - 0.2TO+ 0.2 PLG l
TABLE Vill l TOTAL TUBES PLUGGED TO DATE (1197) l S/G NO. TUBE COUNT PERCENT 11 149 4.40 12 271 8.00 l
L TABLEIX TOTAL TUBES SLEEVED TO DATE (1197)
S/G NO. TUBE COUNT PERCENT l 12 852 25.15 l
Notes: 1 1
@ In situ pressure tested @ Tube pull
@ Post in situ pressure test result @ Preventive plug
@ Additional reroll not attempted @ MRPC not performed
@ Failed additional reroll @ Sleeve welding error
@ New sleeve indication 9 Sleeve pull 1
17
SUMMARY
REPORT NORTHERN STATES POWER INSERVICE INSPECTION PRAIRIE ISLAND UNIT #1,1997 f
LEGEND OF FIELDS AND CODES ElgkQ EXPLANATION l ROW Row number of tube location l COL Column number of tube location LEG Cher.nel head tested from (H = inlet & C = outlet)
BEG Beginning extent of test- see below END Ending extent of test - see below REM Romerks - see below REEL Calibration group t PROBE. Probe size, manufacturer and type used - see belew i
LOCATION Physical Location of Indication - see below l VOLTS Voltage of signal DEG Degree of signal
% Measured percent or three digit code - see below CH Channel number used for measurement FIELD gggg EXPLANATION PROBE *** Probe nominal diameter ZU Standard ULC manufactured by Zetec ZS Spring flex ULC manufactured by Zetec l
MR Mag. Biased Plus Point Rotating coil manufactured by Zetec 1
PR Plus Point Rotating coil manufactured by Zetec CR F* Combo (Bobbin /Plus Point) manufactured by Zetec BEG,END, TEH Tube end hot (primary face)
LOCATION TRH Top of roll expansion hot lag 1BH Bottom of Additional roll expansion #1 hot leg TSH Tube sheet hot (secondary face)
WCH Sleeve Weld Center Line Hot Leg 0?H 7 = First through Seventh tube support plate on hot leg side NV7 7 = First through Forth new antMbration bar 0?C 7 = First through Seventh tube support plate on cold leg side TSC Tube sheet cold (secondary face)
TRC Top of roll expansion cold leg TEC Tube end cold (primary face)
REM F*0 Tube meets F* criteria with no additional roll expansion F*1 Tube meets F* criteria with one additional roll expansion SLV Tube Sleeved PLG Tube Plugged
% DNT Dent DSI Distorted Support Indication MAI Multiple AxialIndication l MCI Multiple Circumferential Indication OBS Obstructed Single AxialIndication !
sal '
SCl Single CircumferentialIndication SVI Single Volumetric indication associated with ARC VOL Volumetric Indication l
l l
i 18 9
AdRTHERN STATES POWER
SUMMARY
REPORT INSERVICE INSPECTION PRAIRIE ISLAND UNIT #1,1997 ATTACHMENTS STEAM GENERATOR 11 - LIST of 0% TO 19% - 2 PAGES STEAM GENERATOR 11 - LIST of 20% TO 29% - 4 P/.GES STEAM GENERATOR 11 - LIST of 30% TO 39% - 2 PAGES STEAM GENERATOR 11 - LIST of 40% TO 100% - 1 PAGE STEAM GENERATOR 11 - LIST of mal, MCI, sal, SCl, SVI, AND VOL - 8 PAGES STEAM GENERATOR 12 - LIST of O's. TO 19% - 1 PAGE STEAM GENERATOR 12 - LIST of 20% TO 29% - 1 PAGE STEAM GENERATOR 12 - LIST of 30% TO 39% - 1 PAGE STEAM GENERATOR 12 - LIST of 40% TO 100% - 1 PAGE STEAM GENERATOR 12 - LIST of mal, MCI, sal, SCl, SVI, AND VOL - 16 PAGES l
4 i
i l 19 l
CUNULATIVE INDICATION 3 REPORT PRAIRIE ISLAND, UNIT 1 Generator 11 Page: 1 of 2 I Leg......: Not and Cold togs Date: 12/05/97 l R21 ease..: 2.2 -
Time: 16:29 0% TO 19% for the entire tength l
I i EXTENT CURRENT 01/96 R0W COL LEG BEG END REM REEL PROSE LOCATION VOLTS DEG % CH REEL ' VOLTS DEG % CH l
1 4 .
. TSH+ 17.6 00085 0.78 124 VOL 2 N 07H TEN 00072 720ZU Tsu+ 17.7 0.21 144 11 P1 00076 0.34 166 13 1 l
i i 1 5 TSH+ 17.6 00085 0.99 126 VOL 2 H OTH TEM 00072 720ZU TSH+ 17.7 0.20 147 11 P1 00076 0.34 170 5 1 l
30 15 01c+ 0.0 00084 0.82 122 VOL 2 C TEN TEC 00035 720ZU 01C- 0.0 0.86 150 1 P1 00004 0.58 148 DS! P1 32 16 C TEN TEC 00036 720Zu 01C- 0.0 0.71 149 11 P1 00003 0.66 145 INR P1 33 16 C TEN TEC 00035 720ZU Dic- 0.0 1.21 128 3 P1 00004 1.13 126 34 P1 i
23 24 C TEH TEC 00041 7202U NV3+ 0.0 0.44 0 9 P2 40 30 C TEM TEC 00042 720Zu NV3+ 0.2 0.64 0 17 P2 00016 1.43 21 P2 42 31 C TEH TEC 00045 720Zu 03C- 0.2 1.07 121 14 P1 00087 0.92 127 15 P1 20 32 C TEM TEC 00047 7202U NV2- 0.2 0.81 0 17 P2 00017 0.57 0 11 P2 C TEH TEC 00047 7202U WV4+ 0.2 0.77 0 16 P2 00017 0.51 0 9 P2 42 32 C TEH TEC PLG 00045 720ZU WV1+ 0.0 0.54 0 15 P2 39 34 C TEH TEC 00045 7202U WV4+ 5.2 0.36 0 11 P2 44 37 C TEH TEC 00049 720ZU 03C+ 0.1 0.37 148 11 P1 44 45 C TEH TEC 00049 720ZU 03C- 0.1 0.77 150 1 P1 00009 0.75 145 INR P1 44 52 C TEH TEC 00055 7202U Dic- 0.0 0.35 128 14 P1 45 52 C TEM TEC 00054 7202U 01C+ 0.0 1.08 126 17 P1 00023 0.79 124 26 P1 45 53 C TEM TEC 00055 720Zu 01C- 0.2 1.19 127 16 P1 00023 0.62 119 32 P1 00054 720Zu Dic- 0.1 1.52 127 15 P1 00023 1.25 121 29 P1 43 54 C TEH TEC 45 54 C TEM TEC PLG 00054 720ZU Dic- 0.2 0.49 133 2 P1 00023 0.30 114 Ds! P1 01C- 0.2 00084 0.14 105 VOL 2 44 55 C TEM TEC 00054 T20ZU NV2+ 0.0 0.76 0 19 P2 00025 0.66 0 17 P2 i C TEN TEC 00054 7202U Hv3+ 0.0 0.65 0 17 P2 00025 0.74 0 18 P2 00055 T20ZU 01C- 0.1 1.06 126 19 P1 00026 1.32 126 31 P1 45 58 C TEM TEC 00054 7207U 03C- 0.2 0.63 138 1 P1 00026 0.65 126 31 P1 43 59 C TEM TEC 00055 7202U NV2+ 0.0 0.84 0 17 P2 00026 1.10 0 22 P2 31 60 C TEM TEC NV2+ 1.4 00026 1.55 0 27 P2 40 66 C TEM TEC 00056 720ZU NV2+ 0.0 0.69 0 17 P2 40 69 C TEH TEC 00056 7202U 03C- 0.3 0.52 137 13 P1 0.2 0.90 131 3 P1 00034 0.83 122 39 P1 37 71 C TEH TEC 00072 720Zu 01C+
00074 7202U 01C+ 0.1 0.90 138 19 P1 00035 0.82 134 11 P1 37 72 C TEM TEC PLG 0.0 0.83 146 8 P1 00037 0.83 136 INR P1 36 76 C TEM TEC 00074 720ZU 01C+
e .
CUNULATIVE INDICATIONS REPORT PRAIRIE ISLAND, UNIT 1 Generators 11 Page: 2 of 2 Leg......: Not and cold legs Date: 12/05/97 R:teese..: 2.2 Times 16:29 0% TO 19% for the entire tength 4
EXTENT CURRENT 01/96 REEL PROSE LOCATION VOLTS DEG % CH REEL VOLTS DEG 1' CH R0W COL LEG BEG END REM 35 77 C TEN TEC 00084 7202U 02C+ 0.2 1.19 131 1 P1 00037 1.15 134 5 P1 00072 7202U 01C- 0.2 1.20 127 12 P1 00040 1.31 120 30 P1 ,
29 80 C TEN TEC 26 81 C TEN TEC 00075 72020 Dic- 0.2 0.37 140 1 P1 00039 0.33 125 28 P1 l
29 81 C TEN TEC 00075 720Zu 01C- 0.1 1.11 145 i P1 0004* 1.02 138 13 P1 27 85 C TEN TEC PLG 00075 720Zu Dic- 0.1 1.02 132 16 P1 00042 0.94 130 25 P1 28 85 C TE7 TEC 00075 720Zu Dic- 0.2 0.47 133 14 P1 00042 0.29 89 DSI P1 01C- 0.2 00083 0.54 120 VOL 2 20 88 C TEH TEC 00075 720ZU 02C- 0.2 0.85 140 1 P1 00042 0.72 135 17 P1 23 88 C TEN TEC 00075 7202U 02C+ 0.1 0.43 133 14 P1 00042 0.38 120 INR P1 15 89 01C+ 0.3 00083 0.82 125 VOL 2 C TEM TEC 00075 7202U 01C- 0.3 0.70 132 16 P1 00043 0.58 110 OSI P1 89 00075 720ZU 01C- 0.1 1.89 133 14 P1 00043 1.75 127 36 P1 19 C TEH TEC 00075 720ZU Dic- 0.2 1.21 132 16 P1 00042 1.10 121 37 P1 19 90 C TEM TEC 00099 720Zu Dic- 0.0 1.45 145 4 P1 7 92 H TEC TEM PLG C 07H TEC PLG 00068 700ZS 01C- 0.1 2.08 136 14 P1 00050 1.05 143 19 P1 3 93 C 07H TEC 00068 700ZS 02C+ 0.1 0.54 143 4 P1 00052 0.67 141 15 P1 93 07H TEC 00068 700ZS 01C+ 0.1 0.90 142 5 P1 00052 0.65 141 15 P1 5 C 9 93 C 07H TEC PLG 00068 700ZS 01C- 0.0 1.38 146 1 P1 00050 0.94 142 20 P1 10 93 C 07H TEC 00068 700ZS 02C- 0.1 1.04 142 5 P1 00050 0.83 135 30 P1 I
! NUMBER OF TUBES IN REPORT = 43 NSP l
I t
i i
l CUMULATIVE INDICATIONS REPORT PRAIRIE ISLAND, UNIT 1 g
Leg......: Not and Cold legs Deter 12/05/97 Reteese..: 2.2 Time: 16:30 20% TO 291 for the entire tength EXTENT CURRENT 01/96 ROW COL LEG BEG END REM REEL PROSE LOCATION VOLTS DEG E CH REEL VOLTS DEG 1 CH 00033 720ZU 01C+ 0.2 1.00 129 26 P1 00006 1.75 127 34 P1 28 11 C TEM TEC 42 28 C TEH TEC 00041 720ZU 03C- 0.2 0.79 136 23 P1 00015 0.87 135 9 P1 40 30 C TEN TEC 00042 720ZU NV4+ 0.1 0.93 0 23 P2 00016 1.27 18 P2 42 32 C TEH TEC PLC 00045 7202U NV2+ 0.1 0.99 0 24 P2 C TEM TEC PLG 00045 720ZU NV3+ 0.2 0.87 0 22 P2 l
I 44 33 C TEN TEC 00047 720Zu 03C- 0.3 0.90 136 26 P1 00018 0.75 128 35 P1 39 35 C TEM TEC 00045 720Zu 07H+ 37.5 0.94 0 23 P2 00013 0.88 0 23 P2 35 37 C TEN TEC 00048 720ZU NV4+ 4.3 0.77 0 20 P2 00013 0.76 0 21 P2 35 38 C TEN TEC PLG 00049 720ZU NV2+ 32.8 1.02 0 20 P2 00013 0.97 24 P2 00048 720ZU NV2+ 33.1 0.79 0 20 P2 00013 1.42 0 22 P2 36 38 C TEN TEC 00049 720ZU NV4+ 6.0 1.11 0 21 P2 00013 0.72 0 20 P2 41 38 C TEH TEC 26 39 C TEM TEC 00049 T20ZU NV3- 0.3 1.29 0 23 P2 00011 0.78 0 20 P2 i 2.03 0 32 P2 00048 720ZU NV2+ 3.0 1.27 0 28 P2 00012 27 39 C TEH TEC 1,39 0.4 0.80 0 20 P2 00012 0 25 P2 C TEM TEC 00046 720ZU NV3-00048 720ZU NV2+ 38.6 0.80 0 20 P2 00012 1.27 0 24 P2 l 41 39 C TEN TEC 1.15 27 P2 00012 1.71 0 29 P2 43 39 C TEH TEC 00048 720ZU NV2+ 40.6 0 40 00049 720ZU 07H+ 33.9 1.30 0 24 P2 00011 1.09 0 25 P2 35 C TEH TEC 1.67 28 P2 00012 1.61 0 28 P2 40 41 C TEH TEC 00049 720Zu 07H+ 35.5 0 1.8 1.51 0 26 P2 00012 1,47 0 26 P2 C TEH TEC 00049 720ZU NV2+
00048 720ZU 07H+ 33.1 1.09 0 26 P2 00011 1.42 0 30 P2 35 42 C TEM TEC 2.8 1.32 0 24 P2 00009 1.27 0 23 P2 36 45 C TEH TEC 00049 720ZU NV4+
00052 720ZU NV2+ 33.8 0.93 0 23 P2 00019 1.04 0 24 P2 37 46 C TEM TEC 36 47 C TEH TEC 00053 720ZU Nv2+ 33.1 1.06 0 20 P2 3.9 1.71 0 28 P2 00019 1.33 0 29 P2 C TEH TEC 00053 720ZU NV4+
Nv2+ 31.6 1.73 0 29 P2 00020 1.68 0 27 P2 35 48 C TEN TEC 00053 720ZU 0.0 1.30 0 29 P2 00019 1.13 0 26 P2 41 48 C TEM TEC 00052 720ZU NV1+
00052 720ZU WV3+ 0.0 0.98 0 24 P2 00019 0.98 0 23 P2 C TEN TEC 00052 720Zu NV4+ 0.0 0.83 0 22 P2 00019 0.92 0 22 P2 C TEH TEC 28 49 C TEH TEC 00052 7202U uv4+ 3.5 0.86 0 22 P2 1.22 0 28 P2 00021 1.21 0 27 P2
! 41 49 C TEN TEC 00052 720ZU Nv2+ 38.3 29 50 C TEH TEC 00053 720ZU NV4+ 3.9 1.10 0 20 P2 2.7 1.27 0 23 P2 00022 1.39 0 24 P2 38 50 C TEM TEC 00053 720ZU Nv2+
1.04 0 20 P2 00022 1.17 0 21 P2 C TEM TEC 00053 720ZU NV2+ 34.8 I NSP l - - - - __ . _ _ _ _ _ _ _ _ _ _ _ - - -
l CUMULATIVE INDICATIONS REPORT l PRAIRIE ISLAND, UNIT 1 Generators 11 Page: 2 of 4 Leg......: Not and Cold legs Date: 12/05/97 R:teese..: 2.2 Time: 16:30 20% TO 29% for the entire length EXTENT CURRENT 01/96 R0W COL LEG BEG END REM REEL PROBE LOCATION VOLTS DEG % CH REEL VOLTS DEG % CH 41 50 C TEM TEC 00052 720ZU 07H+ 37.5 1.21 0 28 P2 00021 1.08 0 25 P2 C TEN TEC 00052 720ZU NV2+ 2.5 1.32 0 29 P2 00021 1.31 0 29 P2 35 51 C TEM TEC 00054 720ZU NV2+ 31.2 0.94 0 23 P2 00021 0.86 0 22 P2 C TEM TEC 00054 720ZU NV4+ 3.4 0.81 0 20 P2 00021 0.76 0 20 P2 l 36 51 C TEM TEC 00055 720ZU NV2+ 2.4 1.15 0 22 P2 00021 0.66 0 20 P2 39 51 C TEM TEC 00054 720ZU NV2+ 36.2 0.89 0 22 P2 00023 1.09 0 25 P2 C TEH TEC 00054 720ZU NV4+ 5.3 0.76 0 20 P2 00023 0.77 0 20 P2 43 51 C TEN TEC 00054 720ZU NV4+ 5.8 1.22 0 27 P2 00023 1.07 0 24 P2 38 52 C TEH TEC 00055 720ZU NV4+ 4.8 1.14 0 22 P2 00024 0.93 0 17 P2 40 52 C TEN TEC 00055 720ZU 07H+ 36.1 1.50 0 27 P2 00024 1.38 0 24 P2 C TEH TEC 00055 7202U NV4+ 5.3 1.56 0 27 P2 00024 1.54 0 26 P2 30 53 C TEM TEC PLG 00055 720Zu 07H+ 33.7 1.58 0 28 P2 00023 1.31 0 28 P2 C TEH TEC PLG 00055 7202U NV2+ 1.6 1.62 0 28 P2 00023 0.81 0 20 P2 38 53 C TEM TEC 00055 720ZU NV2+ 2.2 1.18 0 23 P2 00024 1.25 0 22 P2 C TEH TEC 00055 720ZU NV4+ 5.1 1.64 0 28 P2 00024 1.66 0 27 P2 40 53 C TEH TEC 00055 720Zu NV2+ 37.5 1.01 0 20 P2 43 53 C TEH TEC 00054 720ZU Nv2+ 40.3 1.11 0 26 P2 00023 1.07 0 24 P2 C TEN TEC 00054 720ZU NV4+ 5.6 0.92 0 22 P2 00023 0.97 0 23 P2 44 53 C TEM TEC 00055 7202U 01C- 0.2 3.40 125 22 P1 00024 2.59 129 36 P1 j 29 54 C TEM TEC 00054 720ZU 07H+ 33.1 1.23 0 27 P2 00023 1.37 0 29 P2 C TEH TEC 00054 720ZU NV2+ 1.8 1.19 0 27 P2 00023 0.95 0 22 P2 C TEM TEC 00054 7202U NV2+ 24.9 1.17 0 26 P2 00023 1.26 0 27 P2 C TEN TEC 00054 720ZU NV4+ 2.0 0.99 0 24 P2 00023 0.90 0 21 P2 36 54 C TEH TEC 00055 720ZU NV2+ 33.2 1.52 0 27 P2 00024 1.27 0 22 P2 C TEM TEC 00055 7202U NV4+ 4.9 1.52 0 27 P2 00024 1.62 0 27 P2 31 55 C TEM TEC 00055 720ZU NV4+ 2.2 1.02 0 20 P2 00024 1.09 0 20 P2 37 55 C TEH TEC 00055 7202U NV2+ 33.8 1.26 0 24 P2 00026 1.18 0 23 P2 39 55 C TEM TEC 00055 720ZU NV2+ 36.1 1.16 0 22 P2 00026 1.03 0 21 P2 00055 720ZU NV2+ 2.2 1.13 0 22 P2 00026 1.03 0 21 P2 43 55 C TEN TEC C TEN TEC 00055 720ZU NV2+ 40.6 1.30 0 24 P2 00026 1.18 0 23 P2 26 56 C TEN TEC 00055 7202U NV2+ 21.9 1.12 0 22 P2 00026 1.99 0 32 P2 32 56 C TEM TEC 00055 720ZU NV2+ 1.4 1.24 0 24 P2 00026 1.08 0 21 P2 35 56 C TEH TEC 00054 720Zu NV4+ 2.2 0.99 24 P2 00025 0.72 0 20 P2 40 56 C TEH TEC PLC 00054 720ZU NV4+ 3.9 1.23 0 27 P2 00025 1.14 0 25 P2 41 56 C TEM TEC 00055 720ZU NV4+ 4.2 1.34 0 25 P2 00026 1.17 0 23 P2 I 36 57 C TEM TEC 00054 720ZU NV4+ 2.7 1.04 0 24 P2 00025 0.96 0 22 P2 I
NSP 1
l J
CUNULATIVE INDICATIONS REPORT PRAIRIE ISLAND, UNIT 1
( Cenerator: 11 Page 3 of 4 Leg......: Not and Cold legs Dete: 12/05/97 Release..: 2.2 Time: 16:30 j 20% TO 29% for the entire length ,
l EXTENT I CURRENT 01/%
ROW COL LEG BEG END REW REEL PROBE LOCATION VOLTS DEG %' CH REEL VOLTS DEG % CH 37 57 C TEN TEC 00055 7202U NV2+ 1.8 1.24 0 23 P2 00026 1.15 0 22 P2 39 57 C TEN TECs 00055 720ZU Nv2+ 36.0 1.70 0 29 P2 00025 1.05 0 24 P2 C TEM TEC 00055 720ZU NV4+ 4.2 1.64 0 28 P2 00025 1.19 0 26 P2 38 58 C TEM TLC 00054 7202U NV2+ 34.9 1.18 27 P2 00026 1.43 0 26 P2 C TEN 7EC 00054 7202U NV4+ 5.8 1.11 26 P2 00026 1.24 0 24 P2 39 58 C TEHI TEC 00055 7202U uv2+ 2.3 1.75 0 29 P2 00025 1.26 0 27 P2 43 58 TSH+ 1.1 00026 4.74 161 PLP 8 C TEi TEC 00055 7202U TSH+ 1.2 0.92 125 22 P1 00026 0.87 127 29 P1 TSH+ 1.3 00036 4.58 54 VOL 2 31 59 C !EN TEC 00054 720Z0 07N+ 32.0 0.84 0 21 P2 00087 0.85 0 22 P2 07H+ 32.3 00091 0.89 0 22 P2 C TEH TEC 00054 720Zu 07H+ 33.0 0.77 0 20 P2 00087 0.80 0 21 P2 44 59 C' TEN TEC 00055 720ZU TSH+ 0.6 0.31 123 26 P1 00025 0.36 129 16 1 TSH+ 0.6 00025 0.43 156 25 1 TSH+ 0.7 00038 0.82 80 VOL 2 TSH+ 1.8 00038 0.65 112 VOL 2 31 60 C TEH TEC 00055 7202U 07H+ 33.2 1.42 0 26 P2 00026 1.34 0 25 P2 C TEH TEC 00055 720ZU NV2+ 1.4 1.64 0 28 P2 00026 1.10 0 22 P2 WV2+ 1.4 00026 1.55 0 27 P2 C TEH TEC 00055 720ZU NV4+ 1.7 1.19 0 23 P2 00026 1.23 0 23 P2 27 61 C TEN TEC 00055 7202U NY2+ 1.2 1.43 0 26 P2 00029 1.25 0 22 P2 l C TEH TEC 00055 720ZU NV2+ 22.8 1.27 0 24 P2 00029 1.25 0 22 P2 {
C TEM TEC 00055 720ZU NV4+ 3.2 0.99 0 20 P2 00029 0.98 0 INR P2 37 61 C TEN TEC 00055 720ZU NV2+ 33.6 1.41 0 26 P2 00029 1.24 0 22 P2 40 61 C TEN TEC 00054 720ZU NV2+ 36.5 1.00 24 P2 00029 1.26 0 22 P2 36 62 C TEH TEC 00057 720ZU NV2+ 33.1 1.07 0 21 P2 00029 1.07 0 20 P2 38 62 C TEM TEC 00057 720ZU Nv2+ 35.1 1.74 29 P2 00029 1.76 0 28 P2 C TEM TEC 00057 720ZU NV4+ 3.8 1.69 29 P2 00029 1.51 0 25 P2 36 63 C TEN TEC 00057 720ZU NV2+ 32.2 1.49 0 25 P2 00027 0.97 23 P2 33 64 C TEM TEC 00057 7202U NV2+ 29.3 1.23 0 22 P2 00027 0.72 0 INR P2 30 65 C TEH TEC 00056 720ZU NV2+ 1.7 0.88 22 P2 00027 0.20 0 INR P2 NV2+ 1.8 00027 0.91 0 24 P2 C TEM TEC 00056 720ZU NV4+ 4.1 0.72 20 P2 00027 0.73 0 21 P2 36 66 C TEM TEC 00056 7202U NV2+ 31.5 0.88 0 21 P2 00031 1.09 0 INR P2 j 38 74 C TEH TEC 00074 720Zu 02C+ 0.1 0.30 137 27 P1 31 82 C TEM TEC 00076 7202U 02C- 0.0 0.83 134 21 P1 00039 0.71 130 28 P1 24 86 C TEN TEC 00075 720ZU 01C- 0.3 2.22 126 25 P1 00042 1.43 123 35 P1 l
23 87 C TEH TEC PLG 00076 720Zu 02C- 0.3 0.87 132 25 P1 00042 0.75 120 25 P1
! 23 88 C TEH TEC 00075 720ZU 01C- 0.2 0.82 126 25 P1 00042 1.30 120 38 P1 ]
CUMULATIVE INDICATIONS REPORT PRAIRIE ISLAND, UNIT 1 Generator 11 Page: 4 of 4 Leg......: Hot and Cold legs Date: 12/05/97 R: lease..: 2.2 Time: 16:30 l 20% TO 29% for the entire length ,
EXTENT CURRENT 01/%
PROBE LOCATION VOLTS DEG % CH REEL VOLTS DEG % CH ROW COL LEG BEG END REM REEL 89 TEM TEC PLG 00076 720ZU 02C- 0.1 0.37 132 25 P1 00042 0.35 136 16 P1 20 C 01C+ 0.3 00083 VOL 2 9 91 C OTH TEC 00068 700ZS 01C- 0.3 0.63 127 25 P1 00050 0.99l118 0.37 102 OSI P1 NUMBER OF TUBES IN REPORT = 74 NSP l
l l
l
f CUNULATIVE INDICATIONS REPORT PRAIRIE ISLAND, UNIT 1 Generator: 11 Page 1 of 2 Leg......: Hot and Cold legs Date: 12/05/97 Release..: 2.2 Time: 16:31 30% TO 39% for the entire length EXTENT CURRENT 01/96 l ROW COL LEG BEG END REM REEL PROSE LOCATION VOLTS DEG % CH REEL VOLTS DEG %' CH J f 1 2 H 07H TEM 00072 720ZU TSH+ 17.6 1.14 123 38 P1 00076 1.63 149 37 1
! TSH+ 17.6 00085 3.78 108 VOL 2 l
1 3 TSH+ 17.5 00085 2.51 102 VOL 2 H 07H TEN 00072 720ZU TSH+ 17.7 0.79 127 38 P1 00076 0.78 126 35 P1 l 42 30 C TEH TEC 00042 720ZU 03C- 0.3 0.81 115 38 P1 00016 0.73 91 DSI P1 l 03C- 0.3 00084 0.27 75 VOL 2 42 32 01H+ 2.2 00081 1.09 70 VOL 2 C TEM TEC PLG 00045 720ZU 01H+ 2.4 0.24 107 36 P1 00017 0.51 154 20 1 l
l 01H+ 2.4 00080 0.24 120 APC P1 01H+ 2.5 00085 1.80 352 PLP 5 01H+ 2.7 00085 0.95 79 VOL 2 C TEH TEC PLG 00045 720ZU NV4- 0.0 1.63 0 33 P2 00017 1.31 0 29 P2 35 42 C TEM TEC 00048 720ZU NV2+ 1.8 1.90 0 36 P2 00011 2.31 0 40 P2 41 48 C TEH TEC 00052 720ZU Nv2+ 0.0 1.65 0 34 P2 00019 1.29 0 28 P2 l 41 49 C TEH TEC 00052 720Zu NV4+ 5.1 1.62 0 33 P2 00021 1.44 0 31 P2 43 49 C TEN TEC 00052 720ZU NV2+ 39.9 2.13 0 38 P2 00021 2.02 0 37 P2 C TEH TEC 00052 720ZU NV4+ 5.9 2.06 0 38 P2 00021 1.79 0 35 P2 l
l 36 51 C TEN TEC 00055 7202U NV2+ 33.3 1.99 0 32 P2 00021 1.34 0 29 P2 38 51 C TEM TEC 00055 720ZU NV2+ 35.3 2.36 0 35 P2 00024 2.03 0 31 P2 43 51 C TEM TEC 00054 720ZU NV2+ 40.6 1.53 0 32 P2 00023 1.46 0 30 P2 )
38 52 C TEN TEC 00055 7202U NV2+ 35.5 1.98 0 32 P2 00024 1.87 0 29 P2 j
40 52 C TEN TEC 00055 720ZU NV2+ 2.0 2.89 0 39 P2 00024 2.58 0 35 P2 C TEN TEC 00055 720Zu NV2+ 37.5 2.28 0 34 P2 00024 2.40 0 34 P2 30 53 C TEM TEC PLC 00055 720ZU NV2+ 26.6 2.48 0 36 P2 00023 1.74 0 34 P2 1
36 54 C TEH TEC 00055 720ZU NV2+ 2.1 2.85 0 38 P2 00024 2.96 0 38 P2 00055 720ZU NV2+ 39.6 2.72 0 38 P2 00024 3.06 0 39 P2 f 42 54 C TEM TEC 31 55 C TEH TEC 00055 720ZU NV2+ 27.4 1.91 0 31 P2 00024 1.86 0 29 P2 43 55 C TEH TEC 00055 720ZU NV4+ 4.9 1.95 0 31 P2 00026 1.67 0 29 P2 00055 720ZU Nv4+ 0.2 2.01 0 32 P2 00026 2.64 0 37 P2 26 56 C TEN TEC 36 56 C TEM TEC 00055 7202U NV2+ 1.7 1.97 0 32 P2 00026 1.99 0 32 P2 C TEH TEC 00055 7202U NV4+ 2.7 2.44 0 36 P2 00026 2.36 0 35 P2 00055 720ZU NV2+ 1.8 2.19 0 34 P2 00026 2.34 0 35 P2 35 57 C TEM TEC C TEN TEC 00055 720ZU NV2+ 31.6 2.61 0 37 P2 00026 2.51 0 36 P2 00055 720ZU NV4+ 3.5 2.76 0 38 P2 00025 1.76 0 33 P2 35 58 C TEM TEC 1.93 36 P2 00026 2.62 0 37 P2 38 58 C TEM TEC 00054 720ZU 07H+ 35.4 00055 720ZU NV2+ 35.6 2.19 0 34 P2 00025 1.59 0 31 P2 39 58 C TEH TEC 00025 1.53 0 30 P2 C TEH TEC 00055 720ZU NV4+ 5.5 2.37 0 35 P2 NSP
CUMULATIVE INDICATIONS REPORT PRAIRIE ISLAND, UNIT 1 Generators 11 Page: 2 of 2 Leg......: Not and cold togs Date: 12/05/97 Reteese..: 2.2 Time: 16:31 30% TO 391 for the entfre tength l
! EXTENT CURRENT 01/96 l R0W COL LEG BEC END REM REEL PROSE LOCATION VOLTS DEG 1 CH REEL VOLTS DEG % CH 31 59 C TEN TEC 00054 7202U NV2+ 1.4 2.22 0 39 P2 00087 2.28 0 40 P2 NV2+ 1.4 00091 2.29 0 40 P2 44 59 TSH+ 0.6 00025 0.43 156 25 1 i TSH+ 0.7 00038 0.82 80 VOL 2 l , C TEN TEC 00055 720ZU TSH+ 1.6 0.38 149 30 1 00025 0.36 129 16 1 i TSH+ 1.8 00038 0.65 112 VOL 2 31 60 C TEH TEC 00055 720ZU NV2+ 27.7 2.49 0 36 P2 00026 2.33 0 35 P2 27 61 C TEM TEC 00055 720ZU 07H+ 31.2 2.71 0 38 P2 00029 2.40 0 34 P2 40 67 C TEH TEC 00056 7202U 01C+ 0.0 0.99 122 34 P1 00030 0.95 120 33 P1 33 76 C TEN TEC 00074 720Z0 01C- 0.2 1.36 133 34 P1 00037 1.23 124 27 P1 35 77 C TEN TEC 00084 720ZU 01C- 0.2 1.75 114 37 P1 00037 1.49 116 39 P1 30 80 C TEN TEC 00074 7202U 01C- 0.2 1.25 131 37 P1 00039 0.97 129 30 P1 26 85 C TEM TEC 00076 720ZU 02C- 0.2 1.29 133 35 P1 00043 1.24 128 28 P1 18 90 C TEH 00076 720ZU 01C- 0.2 0.59 129 31 P1 00043 0.53 135 15 P1 TECl l
NUMBER OF TUBES IN REPORT = 34 NSP l
l
CUMULATIVE INDICATIONS REPORT PRAIRIE !$ LAND, UNIT 1 Generator: 11 Page: 1 of 1 Leg......: Not and Cold legs Date: 12/05/97 Release..: 2.2 Time: 16:32 40% TO 100% for the entire length i
! EXTENT CURRENT 01/%
l ROW COL LEG BEG ENO REM REEL PROSE LOCATION VOLTS DEG % CH REEL VOLTS DEG % CH j 45 37 C TEM TEC PLG 00049 720ZU 03C+ 0.0 3.11 110 59 P1 00013 3.0F#.13 36 P1 I 2.95 44 P2 35 40 C TEN TEC 00049 720ZU NV2+ 1.3 3.70 0 43 P2 00011 0 35 48 C TEN TEC 00053 720ZU NV4+ 3.5 3.55 42 P2 00020 3.65 0 42 P2 38 53 C TEN TEC 00055 720Zu NV2+ 35.5 3.25 0 41 P2 00024 3.14 0 39 P2 1 42 54 C TEN TEC 00055 7202U NV4+ 5.7 3.09 0 40 P2 00024 3.05 0 39 P2 38 58 C TEM TEC 00054 720Zu WV2+ 2.1 2.58 42 P2 00026 3.21 0 40 P2 41 58 NV2+ 2.4 00091 3.52 0 48 P2 C TEM TEC 00055 720Zu NV2+ 2.5 4.38 0 46 P2 00087 3.20 0 46 P2 31 59 C TEM TEC 00054 720ZU NV2+ 26.8 3.12 0 46 P2 00087 3.06 0 46 P2 NV2+ 27.1 00091 3.41 0 47 P2 C TEM TEC 00054 7202U NV4+ 5.6 2.64 0 42 P2 00087 2.68 0 43 P2 NV4+ 5.6 00091 2.76 0 43 P2 40 59 C TEH TEC 00055 720ZU NV2+ 2.1 4.06 0 45 P2 00026 3.34 0 41 P2 C TEH TEC 00055 720ZU NV2+ 37.1 4.50 0 46 P2 00026 4.45 0 46 P2 C TEH TEC 00055 720ZU NV4+ 3.8 3.32 0 41 P2 00026 3.00 0 39 P2 36 60 C TEH TEC 00054 7202U NV2+ 1.8 2.61 0 42 P2 00025 2.54 0 41 P2 36 61 C TEH TEC 00054 720ZU 07H+ 34.8 2.48 0 41 P2 00087 2.42 0 41 P2 07H+ 34.9 00091 2.65 0 42 P2 NV2+ 2.0 00091 2.83 0 44 P2 C TEH TEC 00054 720ZU NV2+ 2.1 2.48 41 P2 00087 2.72 0 44 P2 C TEN TEC 00054 7202U NV2+ 32.4 2.31 40 P2 00087 2.51 0 42 P2 NV2+ 32.6 00091 2.62 0 42 P2 1
l l
NUMBER OF TUBES IN REPORT = 11 l
NSP l l
CUMULATIVE INDICATION 2 REPORT PRAIRIE ISLANO, UNIT 1 Generator 11 Page: 1 of 8 Leg......: Not and Cold legs Date: 12/05/97 R: lease..: 2.2 Time: 16:33 MAI, MCI,SAI,$CI,SVI,VOL for the entire tength EXTENT CURRENT 01/%
ROW COL LEG BEG END REM REEL PROBE LOCATION VOLTS DEG % CH REEL VOLTS DEG X CH 1 2 H TSH TSH 00088 720PR TSH+ 17.5T0+ 19.7 2.58 117 VOL 2 00076 1.63 149 37 1 TSH+ 17.6 00085 3.78 108 VOL 2 6 2 C TSC TSC PLG 00085 720PR TSC+ 0.0T0+ 0.7 0.86 106 VOL 2 00059 0.56 148 36 1 C TEC TSC PLG 00203 720PR TSC+ 0.0T0+ 0.7 0.20 107 VOL 2 00084 0.32 113 VOL 2 1 3 H TSH TSH 00088 720PR TSH+ 16.9T0+ 17.5 1.76 119 VOL 2 00076 0.78 126 35 P1 TSH+ 17.5 00085 2.51 102 VOL 2 1 4 H TSH TSH 00088 720PR TSH+ 16.9T0+ 17.6 0.53 128 VOL 2 00076 0.34 166 13 1 TSH+ 17.6 00085 0.78 124 VOL 2 1 5 N TSH TSH 00088 720PR TSH+ 17.3T0+ 17.7 0.80 130 VOL 2 00076 0.34 170 5 1 TSH+ 17.6 00085 0.99 126 VOL 2 13 6 01H+ 0.1 00081 INF 01H+ 0.1 00080 0.72 147 APC P1 N 01H 01H PLG 00088 720PR Q1H- 0.1T0+ 0.2 0.13 94 SVI 2 00008 0.76 149 DSI P1 2 14 H TEH TSH F*0 00004 720PR TRM- 2.7T0- 2.5 5.16 16 SAI 2 3 14 H TEM TSH F*0 00003 720PR TRH- 2.7To- 2.6 2.90 34 SAI 2 1 15 H TEM TSH F*0 00004 720PR TRH- 2.8T0- 2.7 2.50 19 SAI 2 12 15 C TEC TSC PLG 00203 720PR TSC+ 0.4T0+ 0.6 0.20 103 VOL 2 00084 b1 0.$7 112 VOL 2 C TSC TSC PLG 00085 720PR TSC+ 0.4T0+ 0.7 0.82 111 VOL 2 00004 156 25 1 2 17 H TEH TSH F*0 00005 720PR TRH- 2.9To- 2.8 1.85 6 SAI 2 23 17 H TEH TSH F*1 00006 720PR 1BH- 2.1TO- 1.8 2.31 6 SAI 2 00062 6.99 22 MAI 2 H TEH TSH F*1 00006 720PR 1BH- 2.9T0- 2.4 8.10 3 MAI 2 00005 BDA TRH+ 0.1T0+ 0.4 00062 3.35 10 SA1 2 36 18 03H+ 0.1 00081 0.96 124 VOL 2 03H+ 0.1 00080 0.48 90 APC P1 H 03H 03H PLG 00088 720PR 03H- 0.0T0+ 0.3 0.38 117 Svl 2 00003 0.41 101 DS! P1 i i
27 20 H TEH TSH PLG 00009 720PR TSH- 0.0T0+ 0.1 0.44 92 VOL 2 00007 0.61 94 VOL 2 H TEN TSH PLG 00202 720PR TSH- 0.0T0+ 0.2 0.16 106 VOL 2 3 21 M TEH TSH F*0 00009 720PR TRH- 3.0TO- 2.9 4.78 21 MAI 2 27 21 M TEM TSH PLG 00009 720PR TSH- 0.1T0+ 0.1 0.50 89 VOL 2 00006 0.79 94 VOL 2 H 01H TSH PLG 00102 720PR TSH- 0.1T0+ 0.1 0.51 85 VOL 2 H TSH TEM PLG 00102 720PR TSH- 0.1T0+ 0.1 0.64 98 VOL 2 37 21 03H- 0.0 00081 0.43 112 VOL 2 03H- 0.0 00080 0.21 79 APC P1 H 03H 03H PLG 00088 720PR 03H- 0.1T0+ 0.2 0.19 128 SVI 2 00001 0.23 110 DSI P1 25 24 C TSC 01C PLG 00203 720PR TSC+ 23.8T0+ 24.0 0.16 til VOL 2 C 01C TSC PLG 00085 720PR TSC+ 24.0T0+ 23.8 0.61 108 VOL 2 1 25 H TEN TSH F*0 00012 720PR TRM- 2.8T0- 2.6 8.20 15 MAI 2 4 25 N TEN TSH F*0 00010 720PR TRM- 2.7TO- 2.5 6.73 16 MAI 2 5 25 H TEM T$H F*0 00012 720PR TRN- 2.6T0- 2.5 9.52 20 MAI 2 NBP
CUMULATIVE INDICATIONS REPORT PRA!RIE ISLAND, UNIT 1 Generators 11 Page: 2 of 8 Leg......: Not and cold legs Date: 12/05/97 Release..: 2.2 Time 16:33 MAI, MCI, sal,$CI,SVI,VOL for the entire length EXTENT CURRENT 01/%
ROW COL LEG BEG END REM REEL PROSE LOCATION VOLTS DEG % CH REEL VOLTS DEG % CH 10 25 H TEM TSH F*0 00010 720PR TRH- 2.6To- 2.5 3.06 14 SA! 2 20 25 N TEM TSH F*0 00032 720PR TRH- 2.6To- 2.5 2.52 15 SAI 2 l 1 27 H TEH TSH F*0 00014 720PR TRN- 2.8To- 2.5 4.77 18 MAI 2 00010 5.32 13 MAI 2
! 6 27 H TEM TSH F*0 00015 720PR TRN- 2.7To- 2.6 5.21 20 SA! 2 00010 13.19 11 SA! 7 8 27 N TEH TSH F*1 00015 720PR TRH- 0.1TM 0.1 1.94 22 SAI 2 I 1 28 H TEM TSH F*0 00014 720PR TRN- 2.8T0- 2.6 4.49 11 SAI 2 1 29 H TEM TSH F*0 00014 720PR TRN- 2.9T0- 2.8 7.70 11 MAI 2 00013 4.05 10 SAI 2 l
5 29 H TEH TSH F*0 00014 720PR TRH- 2.7To- 2.5 11.52 13 SAI 2 l 19 29 H TEH TSH F*0 00017 720PR TRM- 2.5T0- 2.4 4.65 17 MAI 2 20 29 H TEM TSH F*0 00016 720PR TRN- 2.6To- 2.5 2.47 27 SAI 2 1 30 H TEH TSH F*0 00017 720PR TRH- 2.7to- 2.6 4.89 19 SAI 2 00013 4.83 8 SAI 2 5 30 N TEH TSH F*0 00016 720PR TRH- 2.6TO- 2.5 2.95 26 SA! 2 7 30 H TEM TSH F*0 00016 720PR TRH- 2.7To- 2.5 8.49 28 SAI 2 9 30 H TEH TSH F*0 00016 720PR TRM- 2.8T0- 2.7 4.13 34 SAI 2 13 30 N TEH TSH F*0 00016 720PR TRH- 2.8T0- 2.7 2.88 24 SAI 2 14 30 N TEH TSH F*0 00017 720PR TRH- 2.6T0- 2.5 3.33 21 SAI 2 19 30 H TEH TSH F*0 00016 720PR TRW- 2.8To- 2.7 3.89 36 MAI 2 20 30 N TEN TSH F*0 00017 720PR TRN- 2.5To- 2.5 2.66 15 SA! 2 !
21 30 H TEH TSH F*0 00016 720PR TRM- 2.6To- 2.6 2.52 23 SA1 2 1 31 00073 BDA 00074 80A H TEH TSH F*0 00017 720PR TRM- 2.6To- 2.5 8.15 24 SAI 2 00017 10.05 13 SAI 2 ,
j 5 31 M TEM TSH F*0 00017 720PR TRM- 2.5To- 2.4 3.60 16 SAI 2 7 31 H TEN TSH F*0 00017 720PR TRH- 2.5T0- 2.5 2.27 15 MAI 2 9 31 H TEM TSH F*0 00017 720PR TRH- 2.6To- 2.6 3.49 18 MAI 2 I
10 31 M TEN TSH F*O 00016 720PR TRN- 2.7to- 2.6 4.93 28 SA! 2 2.5 13 31 M TEH TSH F*0 00017 720PR TRH- 2.6T0- 2.91 14 SAI 2 15 31 M TEN TSH F*0 00017 720PR TRW- 2.5To- 2.4 2.10 16 MAI 2 ]
19 31 M TEN TSH F80 00017 720PR TRH- 2.6To- 2.5 2.04 15 MAI 2 21 31 M TEH TSH F*0 00017 720PR TRM- 2.6T0- 2.5 2.83 13 SAI 2 1 32 H TEM TSH F*0 00019 720PR TRM- 3.0To- 2.8 6.53 22 MA1 2 NSP
I CUNULATIVE INDICATIONS REPORT PRAIRIE !$ LAND, UNIT 1 Generators 11 Page: 3 of 8 Leg......: Not and Cold legs Date 12/05/97 Release..: 2.2 Time: 16:33 4
MAI, MCI,SAI, SCI,$VI,VOL for the entire length l
l EXTENT CURRENT 01/96
! R0W COL LEC BEG END REM REEL PROBE LOCATION VOLTS DEG 1 CH REEL VOLTS DEG % CH 6 32 H TEN TSH F*0 00019 720PR TRH- 2.6TO- 2.6 3.09 18 SAI 2 13 32 H TEH TSH F*0 00016 720PR TRN- 2.6T0- 2.5 2.61 13 SAI 2
. 42 32 01H+ 2.4 00080 0.24 120 APC P1
! 01H+ 2.5 00085 1.80 352 PLP 5 N 02H 01H PLG 00097 720MR 01H+ 2.5T0+ 2.9 1.42 94 VOL 2 00017 0.51 154 20 1 01H+ 2.7 00085 0.95 79 VOL 2 H 01H 01H PLG 00090 720PR 01H+ 2.9T0+ 2.5 0.94 80 VOL 2 00081 1.09 70 VOL 2 2 33 H TEN TSH F*0 00018 720PR TRM- 2.5T0- 2.5 2.37 8 SAI 2 12 33 H TEM TSH F*0 00018 720PR TRN- 2.6T0- 2.6 3.30 14 SAI 2 14 33 H TEN TSH F*0 00018 720PR TRH- 2.7TO- 2.6 2.33 17 MAI 2 18 33 H TEM TSH F*0 00018 720PR TRM- 2.6To- 2.5 2.88 18 SA! 2 19 33 H TEH TSH F*0 00019 720PR TRH- 2.8T0- 2.7 2.76 17 SAI 2 1 34 H TEM TSH F*0 00023 720PR TRN- 2.8To- 2.7 6.37 18 SAI 2 H TEM TSH F*O 00020 720PR TRH- 2.8T0- 2.7 5.91 16 SAI 2
, 6 34 H TEM TSH F*0 00020 720PR TRM- 2.5To- 2.4 3.33 13 SAI 2 N TEM TSH F*0 00022 720PR TRM- 2.5T0- 2.4 4.41 13 SAI 2 9 34 H TEH TSH F*0 00020 720PR TRH- 2.7TO- 2.6 2.18 12 SAI 2 10 34 H TEH TSH F*0 00020 720PR TRM- 2.5fo- 2.4 1.45 21 SAI 2 13 34 H TEH TSH F*0 00023 720PR TRH- 2.6To- 2.5 6.31 18 SAI 2 H TEH TSH F*0 00020 720PR TRM- 2.6T0- 2.5 5.90 16 SAI 2 14 34 H TEM TSH F*0 00022 720PR TRH- 2.6TO- 2.5 4.01 13 SAI 2 39 34 C NV4 07C 00094 680PR NV4+ 5.270+ 5.8 0.87 108 VOL 2 43 34 03H+ 0.2 00080 0.54 117 APC P1 M 03H 03H PLG 00089 720PR 03H+ 0.270+ 0.4 0.19 110 SV! 2 00017 0.56 131 DSI P1 03H+ 0.3 00081 0.65 40 VOL 2 1 35 H TEM TSH F*0 00023 720PR TRM- 2.8T0- 2.7 5.95 22 SAI 2 00019 2.62 12 SAI 2 2 35 H TEH TSH F*0 00062 720PR TRM- 2.6TO- 2.5 4.56 10 SAI 2 15 35 N TEM TSH F*0 00063 720PR TRH- 2.4T0- 2.4 1.95 15 SAI 2 1 36 H TEN TSH F*0 00025 720PR TRM- 3.1T0- 2.9 3.65 22 MA! 2 13 36 H TEH TSH F*0 00025 720PR TRM- 2.7To- 2.6 4.93 15 MAI 2 00019 6.81 13 MAI 2 16 36 H TEM TSH F*0 00023 720PR TRM- 2.570- 2.4 4.24 14 MAI 2 21 36 H TEM TSH F*0 00022 720PR TRM- 2.6To- 2.5 5.92 14 SAI 2 00019 2.65 15 SAI 2 44 36 H 03H 03H PLG 00090 720PR 03H+ 0.0T0+ 0.3 0.20 122 SVI 2 00014 0.63 133 28 P1 l
03H+ 0.1 00086 0.66 119 APC P1 03H+ 0.2 00082 0.62 123 VOL 2 37 F*0 00025 720PR TRM- 3.0T0- 2.9 2.68 13 00021 2.62 20 MAI 2 l 2 N TEN TSH NA!l2
[
CUMULATIVE INDICATIONS REPORT PRAIRIE ISLAND, UNIT 1 Generators 11 Page 4 of 8 Leg......: Not and cold legs Date: 12/05/97 j A: lease..: 2.2 Time: 16:33 i MAI. MCI,SAI, SCI,SVI,VOL for the entire length EXTENT CURRENT 01/96 ROW COL LEG BEG END REM REEL PROSE LOCATIDH VOLTS DEG 1 CH REEL VOLTS DEG % CH 9 37 H TEH TSH F*0 00024 720PR TRH- 2.9TO- - 2.8 2.30 12 SAI 2 14 37 N TEN TSH F*0 00025 720PR TRM- 2.9TO- 2.8 4.51 16 MAI 2 16 37 N TEH TSH F*0 00024 720PR TRH- 2.6T0- 2.4 3.89 17 MAI 2 45 37 01R+ 0.2 00085 0.43 79 VOL 2 H 01H 01H PLG C0090 720PR 01 p+ - 0.2TO- 0.0 0.11 66 SVI 2 00013 0.52 125 24 P1 01H- 0.0 00086 0.33 137 APC P1 C 03C 03C PLG 00085 720PR 03C. 0.1T0+ 0.2 7.41 81 VOL 2 00013 3.03 115 36 P1 1 03H+ 0.1 00082 0.45 52 VOL 2 N 03H 03H PLG 00090 720PR 03H+ 0.3T0+ 0.1 0.17 113 SVI 2 00013 0.47 154 IHR P1 1 38 H TEM TSH F*0 00027 720PR TRH- 2.6To- 2.5 3.94 23 SAI 2 l 8 38 H TEH TSH F*0 00027 720PR TRN- 2.6T0- 2.5 4.47 21 MAI 2 1
13 38 TEH+ 0.1T0+ 0.2 00061 0.42 24 SAI 2 H TEH TSH F*0 00026 720PR TRM- 2.770- 2.7 2.31 18 SAI 2 00021 BOA 14 38 H TEM TSH F*0 00026 720PR TRW- 2.9T0- 2.8 3.16 15 SAI 2 16 38 H TEH TSH F*0 00026 720PR TRM- 2.7TO- 2.7 2.57 20 SAI 2 22 38 H TEH TSH F*0 ~ 00026 720PR TRN- 2.8T0- 2.7 1.60 11 SAI 2 35 38 H 01H 01H PLG 00090 720PR 01H+ 0.270- 0.1 0.17 til Sv! 2 1 39 H TEH TSH F*0 00027 T20PR TRH+ 2.6T0- 2.5 9.11 19 MAI 2 00022 4.85 23 MAI 2 l l
2 39 H TEH TSH F*0 00026 720PR TRM- 2.6To- 2.5 3.12 14 SAI 2 7 39 H TEH TSH F*0 00027 720PR TRH- 2.5fo- 2.4 3.36 18 SAI 2 00020 3.48 17 SAI 2 11 39 H 01H 01H PLG 00090 720PR 01H+ 0.2T0+ 0.1 0.09 92 Svl 2 20 39 H TEM TSH F*0 00026 720PR TRH- 2.870- 2.7 5.44 19 SAI 2 22 39 H TEH TSH F*0 00026 720PR TRM- 2.9TO- 2.8 4.95 18 SAI 2 35 39 H TEH TSH F*0 00027 720PR TRH- 2.6TO- 2.5 2.08 9 SAI 2 1 40 N TEM TSH F*0 00027 720PR TRM- 2.6To- 2.5 5.70 22 MA! 2 00022 4.10 19 MAI 2 4 40 H TEM TSH F*0 00027 720PR TRM- 2.5T0- 2.4 4.81 18 SAI 2 22 40 H TEH TSH F*0 00027 720PR TRH- 2.5fo- 2.4 4.65 17 SAI 2 1 41 M TEM TSH F*O 00027 720PR TRM- 2.6TO- 2.5 2.82 19 SAI 2 00022 2.63 14 SAI 2 4 41 M TEM TSH F*0 00026 720PR TRM- 2.870- 2.7 4.16 16 SAI 2 18 41 00082 BDA N TEN TSH F*0 00026 720PR TRM- 2.7TO- 2.7 4.27 17 SAI 2 00022 5.01 17 SAI 2 20 41 M TEH TSH F*0 00026 720PR TRH- 2.9T0- 2.8 4.51 21 SAI 2 00022 3.29 26 SAI 2 l
32 41 M 01H 01H PLG 00088 720PR 01H- 0.2T0+ 0.2 0.24 102 Sv! 2 00012 1.05 137 15 P1 N 01H TSH PLG 00102 720PR 01H- 0.270+ 0.2 0.17 115 SVI 2 00085 0.65 2 73 VOL 2 l 0.86 121 H 02H 01H PLG 00102 720PR 01H- 0.2T0+ 0.2 0.22 121 SVI 2 00086 APC P1 IISP 1
, s .
, CUMULATIVE INDICATIONS REPORT l PRAIRIE ISLAND, UNIT 1 Generator 11 Page: 5 of 8 Leg......: Not and Cold legs Date: 12/05/97 R2Leese..: 2.2 Time: 16:33 MAI, MCI,$Al, SCI,SVI,VOL for the entire length EXTENT CURRENT 01/96 l l ROW COL LEG BEG END REM REEL PROBE LOCATION VOLTS DEG X CH REEL VOLTS DEC % CH' f 9 42 H TEN TSH PLG 00204 720PR 1BN- 0.4T0+ 1.5 0.47 99 MAI 6
20 42 H TEN TSH F*0 00026 720PR TRM- 2.9T0- 2.8 3.78 14 SAI 2 21 42 H TEN TSH F*0 00027 720PR TRH- 2.4TO- 2.3 2.49 19 SAI 2 00022 1.11 98 SAI 2 35 42 H 07H 07H 00088 720PR 07H+ 32.7T0+ 33.2 1.91 96 VOL 2 00011 1.42 0 30 P2 1 43 H TEM TSH F*0 00029 720PR TRN- 2.6TO- 2.5 4.27 16 SAI 2 00026 3.C4 17 SA! 2 i
l 4 43 H TEN TSH PLG 00204 720PR 1BH- 0.6T0+ 2.0 1.38 93 MAI 6 L H TEM TSH PLC 00029 720PR TRH+ 0.1T0+ 0.3 3.25 19 SAI 2 17 43 H TEN TSH F*0 00029 720PR TRM- 2.5To- 2.4 3.84 19 MAI 2 22 43 H TEN TSH F*0 00030 720PR TRH- 2.6To- 2.5 2.73 22 SAI 2 l
1 44 H TEN TSH F*0 00030 720PR TRH- 2.7To- 2.6 2.89 24 SAI 2 00026 2.97 19 SAI 2 10 44 H TEH TSH F*0 00030 720PR TRN- 2.6T0- 2.5 2.12 19 SAI 2 l
l 17 44 TEH+ 0.0T0+ 0.1 00060 1.29 17 SAI 2 F*0 00030 720PR TRH- 2.7To- 2.6 5.48 16 SAI 2 00025 BDA
( H TEN TSH 19 44 H TEH TSH F*0 00030 T20PR TRN- 2.5T0- 2.4 5.07 13 SAI 2 21 44 X TEH TSH F*0 00030 720PR TRM- 2.5T0- 2.4 5.15 17 SAI 2 00025 BDA 22 44 H TEM TSH F*0 00030 720PR TRH- 2.6T0- 2.5 3.62 18 SAI 2 1 45 H TEN TSH F*0 00068 720PR TRM- 2.5TO- 2.6 2.02 13 SAI 2 00061 1.69 11 SAI 2 6 45 H TEN TSH F*0 00068 720PR TRN- 2.4TO- 2.6 1.90 33 SAI 2 19 45 H TEM TSH F*0 00033 720PR TRM- 2.6To- 2.5 4.64 18 MAI 2 I 21 46 H TEH TSH F*0 00034 720PR TRH- 2.8To- 2.7 7.32 21 MAI 2 30 46 H TEN TSH F*1 00033 720PR TRM- 0.0T0+ 0.1 3.15 14 SA! 2 1 48 H TEN TSH F*0 00068 720PR TRH- 2.8To- 2.9 5.20 20 SAI 2 00068 8.83 24 SAI 2 i
13 48 H TEH TSH PLG 00204 720PR 1BH- 0.4T0+ 2.0 0.64 126 MA! 6 '
H TEH TSH PLG 00034 720PR TRH+ 0.1T0+ 0.2 1.9 18 MAI 2 2 49 H TEN TSH F*0 00068 720PR TRH- 2.7TO- 2.6 6.77 18 SAI 2 1 50 M TEH TSH F*0 00067 720PR TRM- 2.7To- 2.6 2.43 12 MAI 2 12 50 N TEH TSH PLG 00204 720PR 1BM- 0.5T0+ 1.0 0.17 143 MAI 6 H TEN TSH PLG 00204 720PR 1BM* 1.2T0- 1.2 0.28 20 SA! 6 H TEM T$N PLC 00034 720PR TRH+ 0.2T0+ 0.2 3.09 16 SA! 2 17 50 X TEM TSH PLG 00202 720PR TRH+ 2.1T0+ 4.1 0.20 72 MAI 2 H TEH TSH PLG 00033 720PR TRH+ 2.3T0+ 4.2 0.41 118 MAI 2 44 50 C 01C 01C PLG 00086 720PR 01C- 0.1To- 0.3 0.37 106 VOL 2 00022 0.52 113 DSI P1 01C- 0.3 00084 0.20 65 VOL 2 NBP I
l l
l CUMULATIVE INDICATIONS REPORT l PRAIRIE ISLAND, UNIT 1 Generator: 11 Page: 6 of 8 Leg......: Not and Cold legs Date: 12/05/97
.A: lease..: 2.2 Times 16:33 MAI, MCI,$AI,5CI,$VI,v0L for the entire length EXTENT CURRENT 01/96 ROW COL LEG BEG END REM REEL PROSE LOCATION VOLTS DEG % CH REEL VOLTS DEG % CH 1 51 M TEM TSH F*0 00067 720Pt TRH- 2.6To- 2.5 6.11 17 SAI 2 44 51 C 01C 01C PLG 00086 720PR 01C+ 0.270- 0.3 0.77 106 VOL 2 00024 0.66 120 DSI P1 01C- 0.2 00084 0.28 119 VOL 2 1 54 H TEN TSH F*0 00066 720PR TRM- 2.6To- 2.5 6.66 17 MAI 2 16 54 01H+ 0.2 00083 1.00 122 VOL 2 01H . 0.1 00086 0.43 131 APC P1 H 01H 01H PLG 00085 720PR 01H- 0.3T0- 0.0 0.29 120 SVI 2 00025 0.32 127 DSI P1 45 54 01H+ 0.1 00086 0.63 72 APC P1 H 01H 01H PLG 00086 720PR 01H+ 0.1T0+ 0.4 0.11 73 SV! 2 00023 0.27 85 DSI P1 01H+ 0.2 00083 INF 1 55 N TEM TSH F*0 00066 720PR TRH- 2.6TO- 2.4 7.55 24 EA! 2 00043 2.02 25 SAI 2 l 5 55 H TEH TSH F*0 00066 720PR TRN- 2.5T0- 2.4 3.46 18 MAI 2 l H TEN TSH F*0 00067 720PR TRM- 2.5To- 2.4 3.30 15 MAI 2 1 56 H TEX TSH F*0 00036 720PR TRM- 2.5To-- 2.5 7.76 12 SAI 2 00043 1.76 19 SAI 2
! 5 56 H TEN TSH F*1 00036 720PR 1BH- 1.4To- 1.3 2.31 23 sAI 2 00043 2.89 32 SAI 2 5 57 .H TEM TSH F*1 00038 720PR TRN- 0.1T0+ 0.1 1.42 24 SAI 2 l
1 58 H TEH TSH F*0 00038 720PR TRH- 2.7To- 2.8 3.18 10 SA! 2 8 58 02H+ 0.0 00089 0.41 129 APC P1 02H+ 0.1 00085 0.42 119 VOL 2 H 02H 02H PLG 00085 720PR 02H- 0.3T0+ 0.2 0.13 121 Sv! 2 00077 0.49 138 32 P1 43 58 H TEH TSH 00039 720PR TSH+ 0.6T0+ 1.5 1.55 104 VOL 2 00026 0.87 127 29 P1 TSH+ 1.1 00026 4.74 161 PLP 8 TSH+ 1.3 00036 4.58 54 VOL 2 l
1 59 H TEH TSH F*O 00038 720PR TRM- 2.9TO- 2.8 3.42 8 SAI 2 40 59 C NV4 NV4 00091 680PR NV4+ 4.0T0+ 4.4 5.24 107 VOL 2 00026 3.00 0 39 P2 1
C NV4 NV4 00091 680PR WV4- 0.5T0+ 0.0 1.94 123 VOL 2 44 59 H TEM TSH 00038 720PR TSH+ 0.4T0+ 0.8 0.57 97 VOL 2 00025 0.36 129 16 1 l TSH+ 0.7 00038 0.82 80 VOL 2 H TEM TSH 00038 720PR TSH+ 1.4T0+ 2.2 0.60 101 VOL 2 00025 0.43 156 25 1 l 00038 0.65 112 VOL 2
' TSH+ 1.8 19 60 X TEM TSH F*0 00064 720PR TRH- 2.5T0- 2.3 6.57 19 MAI 2 00038 3.53 22 MAI 2 12 62 H TEH TSH PLG 00204 720PR 1BN- 0.2T0+ 1.4 0.19 33 MAI 6 H TEM TSH PLG 00042 720PR TRH+ 0.1T0+ 0.3 1.47 11 SA! 2 62 01H+ 0.0 00086 0.56 143 APC P1 24 01H- 0.1 00083 INF M 01H 01H PLG 00086 720PR 01H- 0.2T0+ 0.1 0.06 154 SVI 2 00029 0.49 132 DSI P1 12 63 H TEM TSH F*0 00042 720PR TRM- 2.6TO- 2.5 2.97 13 SA! 2 NBP
CUMULATIVE INDICATIONS REPORT PRAIRIE ISLAND, UNIT 1 l
Generators 11 Page 7 of 8 l
Leg......: Not and cold togs Date: 12/05/97 R21eese..: 2.2 Time: 16:33 MAI, MCI,$AI,$CI,SVI,VOL for the entire tength EXTENT CURRENT 01/96 RCEL PROBE LOCATION VOLTS DEG % CH REEL VOLTS DEG % CH l ROW COL LEG BEG'END REM l 3 64 H TEH TSH PLC 00047 720PR TRH+ 0.1T0+ 0.2 1.39 15 SAI 2
- H TEN TSH PLG 00202 720PR TRH+ 0.1T0+ 0.2 0.55 16 SAI 2 l H TEM TSH PLG 00202 720PR TRH+ 0.9T0+ 2.1 0.19 63 SAI 2 H TEN TSH PLG 00047 720PR TRH+ 1.0T0+ 2.8 0.32 53 SAI 2 24 64 01H- 0.0 00086 0.55 151 APC P1 H 01H 01H PLG 00086 720PR 01H- 0.1T0+ 0.2 0.11 108 SVI 2 00029 0.48 143 DSI P1 43 64 01H+ 0.1 00086 0.73 141 APC P1 H 01H 01H PLC 00086 720PR 01H+ 0.170+ 0.3 0.15 135 SVI 2 00027 0.86 129 DSI P1 65 07H 06H PLG 00086 720PR 06H+ 44.1T0+ 44.6 1.74 25 VOL 2 00029 1.18 7 UDI P1 25 H H 06H 07H PLC 00202 720PR 06H+ 44.7T0+ 44.9 1.03 8 VOL 2 00083 4.73 355 VOL 2 4 66 H TEH TSH PLC 00204 720PR 1BN- 0.6T0+ 1.8 0.57 124 MAI 6 H TEM TSH PLG 00049 720PR TAH- 0.0T0+ 0.1 1.33 17 SAI 2 1 68 H TEH TSH F*0 00050 720PR TRH- 2.8To- 2.9 4.34 13 SAI 2
! 5 69 02H+ 0.1 00089 0.44 138 APC P1 i 00085 0.55 113 VOL 2 l 02H+ 0.2 l 0.3T0+ 0.3 0.12 94 SVI 2 00078 0.34 125 DSI P1 l H 02H 02H PLG 00086 720PR 02H-1 70 N TEH TSH F*0 00052 720PR TRH- 2.7TO- 2.6 6.33 19 MAI 2 00047 0.99 24 SAI 2 1 72 H TEH TSH F*0 00052 720PR TRN- 2.8To- 2.5 1.96 13 SAI 2 i
37 72 C 02C 02C PLG 00086 720PR 02C+ 0.3T0+ 0.0 0.60 98 VOL 2 1 73 H TEH TSH F*0 00052 720PR TRH- 2.8T0- 2.7 2.70 13 SAI 2 1
11 74 H 01H 01H PLG 00086 720PR 01H- 0.1T0+ 0.1 0.15 148 SVI 2 34 01C 01C PLG 00086 720PR 01C- 0.1TO- 0.3 0.79 96 VOL 2 00037 0.39 119 DSI P1 74 C 01C- 0.3 00084 0.22 101 VOL 2 l
1 76 H TEN TSH F*0 00056 720PR TRM- 2.8TO- 2.7 4.94 16 sal 2 00052 4.59 9 SAI 2 17 77 H TEH TSH PLG 00056 720PR TRH+ 1.6T0+ 1.7 1.34 37 SA! 2 00056 720PR 01C- 0.1TO- 0.3 1.10 108 VOL 2 00037 1.36 119 36 P1 32 77 C 01C 01C PLG F*0 00056 720PR TRM- 2.8TO- 2.5 9.18 21 SAI 2 00052 7.47 to SAI 2
~
1 78 H TEM TSH F*1 00054 720PR 18H- 2.9T0- 2.2 12.69 25 MAI 2 00051 4.00 21 MAI 2 8 78 H TEM TSH l 00037 0.56 45 DSI P1 32 78 C 01C 01C PLG 00086 720PR 01C+ 0.210- 0.1 0.41 59 VOL 2 01C- 0.3 00084 0.60 92 VOL 2 f
0.75 121 DSI 00086 720PR 01C+ 0.4T0+ 0.2 0.67 98 VOL 2 00038 P1
! 31 79 C 01C 01C PLG 01C- 0.4 00084 0.25 133 VOL 2 01C+ 0.1 00083 0.76 159 VOL 2 31 81 00086 720PR 01C+ 0.1To- 0.2 0.54 110 VOL 2 00039 0.63 147 DS! P1 C 01C 01C PLG 23 84 C 01C 01C PLG 00086 720PR 01C+ 0.170- 0.3 0.48 109 VOL 2 0.0T0+ 0.3 0.17 109 SVI 2 00042 0.34 104 DSI P1 27 85 H 02H 02H PLG 00087 720PR 02H+
00086 0.41 89 APC P1 02H+ 0.2 02H+ 0.3 00083 0.51 72 VOL 2 NSP
)
CUNULATIVE INDICATIONS REPORT PRA!RIE ISLAND, UNIT 1 e Page: 8 of 8 Generator 11 Leg......: Not and Cold legs Date: 12/05/97 Reteese..: 2.2 Times 16:33 -
mal, MCI,SAI,5CI,SVI,VOL f or the entire length EXTENT CURRENT 01/96 REEL PROSE LOCATION VOLTS DEG % CH REEL VOLTS DEG % CH R0W COL LEG 8EG END REM 87 N TEH TSH F*0 00060 720PR TRM- 2.7TO- 2.5 4.46 42 SAI 2 00056 2.95 41 sat 2 1
23 87 C 01C 01C PLG 00086 720PR 01C+ 0.0TO- 0.4 1.10 118 VOL 2 00042 0.74 65 DSI P1 01C- 0.3 00083 0.79 294 VOL 2 18 89 C 01C 01C PLG 00086 720PR 01C+ 0.3T0+ 0.2 0.55 140 VOL 2 00042 0.63 100 DS! P1 C 01C 01C PLG 00086 720PR 01C- 0.1To- 0.3 0.64 129 VOL 2 00083 0.48 122 VOL 2 00086 720PR 01C+ 0.1T0- 0.3 1.82 107 Vol 2 00042 0.83 122 36 P1 i 20 89 C 01C 01C PLG C TSC 01C PLG 00203 720PR 01C- 0.3To+ 0.1 0.48 105 VOL 2 14 90 C 01C 01C PLG 00086 720PR 01C- 0.1TO- 0.3 0.56 139 VOL 2 16 90 01H+ 0.0 00086 0.61 101 APC P1 N 01H 01H PLG 00087 720PR 01H+ 0.1To* 0.3 0.14 136 SV1 2 00043 0.49 107 DSI P1 01H+ 0.3 00083 0.76 108 VOL 2 14 91 01H+ 0.1 00086 0.47 75 APC P1 H 01H 01H PLC 00087 720PR 01H+ 0.2T0+ 0.4 0.23 146 SVI 2 00042 0.36 94 DS! P1 01H+ 0.3 00083 0.92 142 VOL 2 7 92 02C+ 0.2 00083 0.49 130 VOL 2 C 02C 02C PLG 00086 720PR 02C- 0.1TO- 0.3 0.60 115 VOL 2 00050 0.33 78 DSI P1 7 93 C 03C 03C PLG 00086 720PR 03C- 0.2T0- 0.4 1.01 58 VOL 2 00050 0.26 84 DSI P1 03C- 0.4 00083 0.86 72 VOL 2 9 93 H 01H 01H PLG 00087 720PR 01H+ 0.0T0+ 0.4 0.18 100 SVI 2 NUMBER OF TUBES IN REPORT = 180 NSP i
l l
f
CUMULATIVE INDICATIONS REPORT PRA!RIE ISLAND, UNIT 1 Generator: 12 Page: 1 of 1 Leg......: Hot and Cold togs Date: 12/05/97 Reteese..: 2.2 Time: 16:34 0% TO 19% f6r the entire length l
f EXTENT CURRENT 01/%
! R0W COL LEG BEG END REM REEL PROSE LOCATION VOLTS DEG % CH REEL VOLTS DEG' % CH 42 60 C TEM TEC 00048 7202U 01C+ 0.1 1.24 135 1 P1 00023 1.19 131 10 P1 l
44 60 C TEM TEC PLG 00048 720ZU 01C+ 0.1 1.84 127 9 P1 00023 1.92 122 34 P1 39 66 C TEM TEC 00043 720ZU 01C+ 0.3 0.40 130 9 P1 40 66 C TEN TEC 00042 720Z0 01C+ 0.1 0.48 139 15 P1 00023 0.58 131 10 P1 37 71 C TEM TEC 00053 720ZU 01C+ 0.2 1.91 137 1 P1 00033 1.67 132 21 P1 38 72 C TEM TEC PLG 00053 720ZU 01C+ 0.2 1.88 138 1 P1 00033 1.52 134 16 P1 37 73 C TEN TEC 00057 720ZU 01C+ 0.1 1.24 145 1 P1 00033 1.50 130 26 P1 36 75 C TEM TEC PLG 00057 720ZU 01C+ 0.1 1.15 135 10 P1 00033 1.16 128 30 P1 35 77 C TEH TEC PLG 00056 720Zu 01C+ 0.0 1.41 142 1 P1 00033 1.13 134 16 P1 29 80 C TEN TEC 00056 720ZU 01C+ 0.0 0.82 137 1 P1 00030 0.71 134 11 P1 28 83 01C+ 0.1 00054 0.15 116 VOL 2 C TEH TEC 00057 720ZU 01C+ 0.2 0.55 156 1 P1 00033 0.46 145 DSI P1 22 84 C TEM TEC 00057 720Zu 01C+ 0.2 0.62 150 1 P1 00030 0.68 148 INR P1 25 84 C TEN TEC 00056 7202U 01C- 0.1 0.97 141 1 P1 00033 0.95 139 2 P1 22 86 C TEN TEC 00057 720ZU 01C+ 0.1 0.95 146 1 P1 00029 1.08 139 25 P1 23 86 C TEH TEC 00056 7202U 01C+ 0.0 0.83 144 1 P1 00030 0.87 134 11 P1 26 86 C TEN TEC 00057 720ZU 01C- 0.1 0.93 142 1 P1 00033 0.92 136 11 P1 24 87 C TEM TEC 00056 720ZU 01C- 0.1 0.60 147 1 P1 00029 0.78 144 20 P1 20 88 01C+ 0.0 00054 0.13 66 VOL 2 C TEH TEC 00057 720ZU 01C- 0.0 0.53 140 1 P1 00030 0.52 134 DSI P1 19 89 C TEM TEC 00057 720Zu 01C+ 0.0 0.32 136 7 P1 00030 0.43 134 11 P1 16 90 C TEM TEC PLG 00057 720ZU 01C+ 0.0 0.24 146 i P1 00030 0.20 78 DSI P1 Dic- 0.1 00054 0.06 118 VOL 2 NUMBER OF TUBES IN REPORT = 20 NSP i
CUMULATIVE INDICATIONS REPORT PRAIRIE ISLAND, UNIT 1 Generator 12 Page: 1 of 1
( Leg......: Not and Cold legs Date: 12/05/97 Release..: 2.2 Times 16:35 20% TO 29% for the ontIre !ength EXTENT CURRENT 01/96 ROW COL LEG BEG END REM REEL PROSE LOCATION VOLTS DEG % CH REEL VOLTS DEG % CH 31 17 C TEN TEC 00029 720ZU 05C- 0.3 0.53 125 22 P1 00003 0.50 94 DS! P1 05C- 0.3 00054 0.29 103 VOL 2 18 27 C STM TEC 00036 720Zu NV4+ 2.4 1.35 0 24 P2 00007 1.35 0 23 P2 18 30 C TEM TEC 00033 7202U NV2+ 1.0 1.05 0 20 P2 00008 1.27 0 21 P2 19 33 C STM TEC 00038 7202U 07N+ 24.3 1.44 0 22 P2 00010 0.93 0 INA P2 l C STM TEC 00038 7202U Nv2+ 0.3 1.50 0 22 P2 00010 0.97 0 INA P2 41 35 C TEH TEC 00052 7202U NV4+ 6.6 1.07 0 20 P2 00010 1.30 0 24 P2 44 39 C TEM TEC 00034 7202U Nv2+ 0.0 1.11 22 P2 41 41 C TEM TEC 00037 720ZU NV2+ 0.0 1.53 0 28 P2 00012 1.30 0 26 P2 C TEH TEC 00037 7202U NV3+ 0.0 1.62 0 29 P2 00012 0.97 0 22 P2 C TEM TEC 00037 720ZU NV4+ 0.0 1,49 0 27 P2 00012 0.90 0 20 P2 22 47 C TEH TEC SLV 00051 720ZU NV2+ 16.9 1.47 0 25 P2 00031 1.10 0 INR P2 38 48 C TEH TEC 00052 720ZU Nv4+ 7.4 1.55 0 26 P2 00031 1.49 0 23 P2 17 49 C TEH TEC 00050 720ZU 07H+ 24.5 1.06 0 21 P2 00015 1.22 0 23 P2 C TEM TEC 00050 720ZU NV2+ 1.6 1.42 0 25 P2 00015 2.03 0 32 P2 C TEM TEC 00050 7202U NV2+ 12.4 1.23 0 23 P2 00015 1.19 0 23 P2 18 49 C TEM TEC 00049 720ZU 07H+ 25.3 1.02 0 20 P2 00031 0.80 0 INR P2 C TEN TEC 00049 720ZU Nv2+ 1.7 1.71 0 28 P2 00031 1.28 0 20 P2 24 50 C TEM TEC SLV 00049 720ZU NV2+ 19.7 1.11 0 21 P2 00018 1.00 0 20 P2 41 50 C TEH TEC 00049 720ZU WV2+ 38.5 1.46 0 25 P2 00015 1.60 0 28 P2
! 41 51 C TEM TEC 00050 720ZU NV2+ 37.5 1.17 0 22 P2 00017 1.01 0 19 P2 l C TEM TEC 00050 720ZU NV4+ 7.6 1.33 0 24 P2 00017 1.23 0 22 P2 i
- 24 52 C TEM TEC 00050 720ZU NV2+ 0.7 1.30 0 24 P2 00018 1.43 0 25 P2 33 53 C TEM TEC 00050 720Zu Nv2+ 29.7 0.98 0 20 P2 00018 1.02 0 20 P2 36 53 C TEM TEC 00049 720ZU NV3+ 16.1 1.11 0 21 P2 00017 1.11 0 20 P2 22 57 C TEH TEC 00050 720ZU NV2+ 18.7 1.16 0 21 P2 00021 1.18 0 21 P2 22 61 C TEM TEC 00047 720ZU NV2+ 18.7 1.27 0 23 P2 00024 1.25 0 21 P2 18 62 C TEM TEC 00044 720ZU WV2+ 14.2 1.29 22 P2 00024 1.22 0 22 P2 25 68 C TEM TEC 00042 720ZU 07H+ 28.7 1.28 23 P2 00023 1.65 0 26 P2 30 81 C TEH TEC 00056 7202U 01C+ 0.3 0.70 125 28 P1 00029 1.33 159 3 P1 i
l 17 90 C TEM TEC 00056 720ZU 01C- 0.0 0.83 125 28 P1 00033 0.74 133 19 P1 NUMBER OF TUBES IN REPORT = 23 NSP
CUMULATIVE INDICATIONS REPORT PRAIRIE ISLAND, UNIT 1 Generators 12 Page: 1 of 1 Leg......: Not and Cold legs Date: 12/05/97 Release..: 2.2 Times 16:35 30% TO 395 for the entire length EXTENT CURRENT 01/96 ROW COL LEG BEG END REM REEL FROSE LOCATION VOLTS DEG % CH REEL VOLTS DEG % CH 41 29 C TEN TEC '00032 720ZU NV2+ 0.0 2.51 0 34 P2 00008 1.73 0 28 P2 i C TEM TEC 00032 720ZU NV3+ 0.0 2.33 0 33 P2 00008 1.77 0 28 P2 l
41 41 C TEN TEC 00037 720ZU NV1+ 0.0 2.51 0 36 P2 00012 1.97 0 32 P2 40 68 C TEN TEC 00043 720Z0 01C+ 0.2 1.26 125 31 P1 00024 2.01 141 INR P1 19 87 C TEN TEC 00057 720ZU 01C- 0.1 0.49 123 39 P1 00030 0.68 130 21 P1
! NUMBER OF TUBES IN REPORT = 4 MSP l
l l
1 l
l
(_.
l
. a e l
CUMULATIVE INDICATIONS REPORT PRAIRIE !$ LAND, UNIT 1 l
i Generator: 12 Page: 1 of 1 Leg...... Hot and Cold legs Date: 12/05/97 R2 lease..: 2.2 Time: 16:36 40% TO 100% for the entire length EXTENT CURRENT 01/96 PROBE LOCATION VOLTS DEG % CH REEL VOLTS DEG % CH ROW COL LEG BEG END REM REEL 42 61 01C+ 0.2 00054 0.11 138 VOL 2 C TEM TEC PLG 00048 720ZU 01C+ 0.3 0.44 112 47 P1 00024 0.43 106 DSI P1 f NUMBER OF TUBES IN REPORT = 1 NBP 1
i l
l l
l l
l I
I
l l
)
l CUMULATIVE INDICATIONS REPORT PRAIRIE ISLAND, UNIT 1 Generator: 12 Popes 1 of 16 Leg......s Hot end Cold legs Date: 12/05/97 l Times 16:37 Release..: 2.2
! MAI, MCI,SAI,5CI,SVI,VOL for the entire length l
EXTENT CURRENT 01/96 REEL PROBE LOCATION VOLTS DEG % CH REEL VOLTS DEG % CH R0W COL LEG BEG END REM 3 3 H TEN TSH PLG 00001 720PR TRH+ 9.970+ 12.7 0.60 131 MAI 2 8 4 H TEM TSH PLG 00001 720PR TR H+ 6.8T0+ 10.7 0.39 124 SAI 2 5 6 H TEN TSH SLV 00003 720PR TR N+ 0.5T0+ 9.1 0.39 142 SAI 2 6 6 H TEM TSH SLV 00004 720PR TR H+ 3.6T0+ 7.5 0.65 139 MAI 2 4 7 H TEM TSH SLV 00003 720PR TRN+ 0.3T0+ 8.8 0.55 1 08 MAI 2 6 7 N TEN TSH SLV 00003 720PR TRH+ 0.6T0+ 5.2 0.27 144 SAI 2 9 7 N TEM TSH SLV 00003 720PR TRH+ 0.5T0+ 10.8 0.48 107 MAI 2 H TSH TEM SLV 00230 720PR TRH+ 0.5T0+ 10.8 0.24 117 MAI 2 16 7 H TEM TSH PLG 00004 720PR TRH+ 2.5T0+ 4.8 0.43 102 SAI 2 2 8 H TEM TSH SLV 00003 720PR TRH+ 6.1T 0+ 8.5 0.33 142 SAI 2 4 8 H TSH TEM SLV 00230 720PR TRH+ 0.4T0+ 10.5 0.46 114 MAI 2 H TEH TSH SLV 00003 720PR TRH+ 0.5T0+ 9.5 1.19 124 MAI 2 6 8 H TEH TSH SLV 00003 720PR TRH+ 0.4T0+ 4.0 0.44 129 MAI 2 9 8 H TEM TSH SLV 00003 720PR TRH+ 0.4T0+ 9.0 0.49 131 MAI 2 9 9 H TSH TEM SLV 00230 720PR TRN+ 0.4T 0+ 10.9 0.37 122 MAI 2 H TEH TSH SLV 00004 720PR TRH+ 1.2T0+ 10.3 0.52 127 MAI 2 3 11 H BUH STM PLG 00244 610PR WCH- 0.2T0+ 0.2 0.93 33 VOL P3 00034 42.11 5 VOL P1 H TEM STH PLC 00085 610PR WCH- 0.3T0+ 0.2 0.65 26 VOL P3 00019 8.65 71 VOL 3 5 11 N TEN TSH SLV 00005 T20PR TRH+ 0.4T0+ 8.8 0.43 137 SAI 2
! 14 11 N TEM TSH SLV 00005 720PR TRH+ 0.1T0+ 0.1 1.51 11 SA! 2 19 11 H 01H 01H PLG 00110 720PR 01H+ 0.0T0+ 0.1 0.13 128 SAI 2 0.1T0+ 0.1 0.12 129 SA! 2 i H 01H TSH PLG 00129 720PR 01H-H 02H 01H PLG 00129 720PR 01H- 0.1T0+ 0.1 0.13 117 SAI 2 H 03H 02H PLG 00129 720PR 02H+ 7.7T 0+ 8.2 0.07 141 VOL 2 H 03H 02H PLG 00129 720PR 03H- 0.410- 0.2 0.07 94 SAI 2 00129 720PR TRH+ 0.3T0+ 14.0 0.32 121 SAI 2 00037 INF 1 H TSH TEN PLG l
! 16 12 H TSH TEH SLV 00230 720PR TRH+ 0.6T0+ 9.8 0.34 127 MAI 2 H TEM TSH SLV 00005 720PR TRH+ 4.1T 0+ 10.0 0.63 134 MAI 2 8 13 H TEM TSH SLV 00005 720PR TRH+ 6.9T0+ 7.5 0.36 125 SAI 2 l
21 13 H TEM TSH SLV 00005 720PR TRH+ 0.5T0+ 9.1 0.37 130 MAI 2 13 14 H TEH TSH SLV 00025 720PR TRH+ 0.4T0+ 9.7 0.20 138 SAI 2 H TSH TEM SLV 00230 720PR TRH+ 0.4T 0+ 10.5 0.14 97 MAI 2 17 15 H TEM TSH SLV 00007 720PR TRH+ 0.170+ 0.2 2.63 11 SA! 2 6 16 H TEN TSH SLV 00007 720PR TRH+ 0.1T0+ 0.2 3.30 12 MAI 2 0.2T0+ 0.1 0.65 136 VOL P3 00019 17.84 150 VOL 3 8 16 H TEM STM PLG 00085 610PR WCH-00244 610PR WCH- 0.2T0+ 0.1 0.69 119 VOL P3 00034 44.15 7 VOL P1 H BUH STH PLG lisp
CUNULATIVE INDICATIONS REPORT PRAIRIE ISLAND, UNIT 1 Generators 12 Page: 2 of 16 Leg......: Not and Cold legs Date: 12/05/97 Release..: 2.2 Time: 16:37 MAI, MCI,SAI,5Cl,$VI,VOL for the entire tength I
EXTENT CURRENT 01/96 )
R0W COL LEG BEG END REM REEL PROBE LOCATION VOLTS DEG 1 CH REEL VOLTS DEG % CH 20 16 H TEM TSH SLV 00007 720PR TRH+ 0.0To+ 0.1 2.14 14 SAI 2 25 16 BUN + 0.7 00126 5.84 5 VOL 7 H TEM STM PLG 00085 610PR WCH- 0.2T0+ 0.4 11.29 14 VOL P3 00122 13.25 7 SWI P3 H BUM STM PLG 00244 610PR WCH- 0.3To+ 0.4 10.70 22 VOL P3 00125 9.64 6 VOL P3 13 17 N TEM STM PLG 00108 610MR WCH- 0.2T0+ 0.2 1.90 18 MCI P3 H BUM STN PLG 00244 610PR WCH- 0.2T0+ 0.3 1.34 34 MCI P3 31 17 05C- 0.3 00054 0.29 103 VOL 2 C 05C 05C 00301 720CR 05C- 0.3T0- 0.1 0.42 105 VOL 6 00003 0.50 94 DSI P1 17 18 BUN + 0.8 00145 1.59 21 VOL 7 H TEM STN PLG 00083 610PR WCH- 0.1T0+ 0.3 4.73 16 VOL P3 00141 3.10 23 SWI P3 H BUN STM PLG 00244 610PR WCH- 0.1T0+ 0.3 3.64 26 VOL P3 00143 3.00 12 VOL P3 5 19 H TEM TSH SLV 00009 720PR TRH+ 1.9To+ 3.1 0.27 133 SAI 2 23 19 H TEM TSH SLV 00011 720PR TRH+ 0.1To+ 0.1 2.49 9 SAI 2 5 20 N TEM STN 00108 610MR WCH- 0.1To+ 0.3 0.81 20 VOL P3 H BUH STM 00244 610PR WCH- 0.1T0+ 0.4 0.86 152 VOL P3 3 21 M TEM TSH SLV 00012 720PR TRH+ 0.1T0+ 0.2 1.90 17 MAI 2 14 21 M TSH TEH SLV 00230 720PR TRH+ 1.6To+ 2.5 0.08 60 MAI 2 H TEH TSH SLV 00011 720PR TRH- 0.1To+ 0.0 7.32 13 MAI 2 H TSH TEM SLV 00230 720PR TRN- 0.2To+ 0.2 2.08 18 MAI 2 16 21 N TEH TSH SLV 00012 720PR TRH+ 0.170+ 0.2 2.17 11 MAI 2
[ 23 21 M TEM TSH SLV 00012 720PR TRH+ 0.2To+ 0.3 1.93 5 SAI 2 1
I l
l 24 21 H TEH TSH SLV 00012 720PR TRH+ 0.1To+ 0.2 2.17 14 MAI 2 17 22 BUH+ 0.3 00126 5.% 8 VOL 4 H TEM STM PLG 00080 610PR WCH- 0.2To+ 0.4 7.37 19 VOL P3 00124 4.52 13 SWI P3 H BUH STM PLG 00244 610PR WCH- 0.2T0+ 0.4 4.27 25 VOL P3 00125 3.40 2 VOL 6 6 23 H TEH TSH SLV 00012 720PR TRH+ 0.2T0+ 0.2 1.80 11 SAI 2 l l
! 13 23 H TEN TSH SLV 00024 720PR TRH+ 0.1T0+ 0.2 3.02 9 SAI 2 l H TEH TSH SLV 00024 720PR TRH+ 9.1To+ 9.6 0.19 121 SAI 2 16 23 H TEM TSH SLV 00012 720PR TRH+ 0.170+ 0.2 3.20 15 MAI 2 19 23 H TEN TSH SLV 00012 720PR TRH+ 0.1T0+ 0.2 2.31 16 SAI 2 23 23 H TEM TSH SLV 00012 720PR TRH+ 0.170+ 0.2 1.23 6 SAI 2 19 25 BUN + 0.6 00138 4.53 3 VOL 7 N TEM STN PLG 00080 610PR WCH- 0.1T0+ 0.3 9.46 14 VOL P3 00136 6.01 10 SWI P3 H BUM STH PLG 00244 610PR WCH- 0.1To+ 0.4 6.99 17 VOL P3 00137 5.20 1 73 VOL 6 15 26 H TEM TSH SLV 00039 720PR TRH+ 0.2To+ 0.3 0.89 11 SA! 2 21 26 H TEM TSH SLV 00039 720PR TRH+ 0.2T0+ 0.3 2.72 14 MAI 2 23 26 H TEM TSH SLV 00022 720PR TRH+ 0.2To+ 0.3 2.23 20 SAI 2 NSP
l
[ . .
CUNULATIVE INDICATIONS REPORT j PRAIRIE ISLAND, UNIT 1 Generator: 12 Pages 3 of 16 L eg. . . . . . : Not and Cold legs Date: 12/05/97 Release..: 2.2 Time: 16:37 MAI, MCI,$AI, SCI,$VI,VOL for the entire tength EXTENT CURRENT 01/96 ROW COL LEG BEG END REM REEL PROSE LOCATION VOLTS DEG % CH REEL VOLTS DEG % CH 27 26 H TEM TSH SLV 00226 720PR 1BH- 1.0T0+ 2.1 0.24 89 MAI 2 H TEH TSH SLV 00022 720PR TRH+ 0.1T0+ 0.1 1.75 8 SAI 2 l
4 27 H TEH TSH SLV 00022 720PR TRR+ 0.1T0+ 0.2 1.51 15 SA! 2 !
12 27 H TEM TSH SLV 00023 720PR TRH- 0.1T0+ 0.2 2.40 11 SAI 2 37 27 H TEN TSH PLG 00022 720PR TSH- 0.1T0+ 0.1 2.15 109 VOL 2 00049 2.45 108 VOL 2 4 28 H TEH STM PLG 00108 610MR WCH+ 0.0T0+ 0.3 3.19 23 VOL P3 H BUH STN PLG 00244 610PR WCH+ 0.0T0+ 0.3 3.25 22 VOL P3 6 28 H TEM TSH SLV 00023 720PR TRH+ 0.5T0+ 2.4 0.32 133 SAI 2 11 28 H TEN TSH SLV 00022 720PR TRH+ 0.1T0+ 0.1 1.27 11 SAI 2 i 13 28 H BUH STN PLG 00244 610PR WCH- 0.1T0+ 0.3 1.38 18 MCI P3 H TEH STN PLC 00108 610MR WCH- 0.1T0+ 0.4 1.67 12 MCI P3 2 29 H TEH TSH SLV 00023 720PR TRN- 0.0T0+ 0.2 2.54 14 SAI 2 .
5 29 H TEH TSH SLV 00023 720PR TRH+ 1.3T0+ 2.3 0.36 152 SA! 2 H TEM TSH SLV 00023 720PR TRH- 0.0T0+ 0.2 1.86 7 SAI 2 11 29 H TEM TSH SLV 00022 720PR TRH+ 0.1T0+ 0.2 1.72 21 MAI 2 I
12 29 H TEH TSH SLV 00023 720PR TRH+ 0.170+ 0.1 0.68 23 SAI 2 i 27 29 03H+ 0.1 00056 0.67 145 APC P1
! 03H+ 0.1 00092 0.09 110 INR 2 H 03H 03H PLG 00110 720PR 03H- 0.1T0+ 0.2 0.09 88 SVI 2 00008 0.58 123 5 P1 29 29 H TEM TSH SLV 00226 720PR 1BM- 0.970+ 2.2 0.61 162 MAI 2 H TEH TSH SLV 00226 720PR 1BH- 1.2T0- 1.1 0.20 20 SAI 2 H TEM TSH SLV 00022 720PR TRM- 0.0T0+ 0.1 2.44 10 MAI 2 6 30 N TEM TSH SLV 00023 720PR TRH+ 0.1T0+ 0.2 1.03 18 SAI 2 l 9 30 N TEM TSH SLV 00023 720PR TRH+ 0.170+ 0.2 2.38 17 SAI 2 00006 0.51 0 INR P1 l
22 30 H TEM TSH SLV 00022 720PR TRH+ 0.1T0+ 0.1 2.41 11 SAI 2 34 30 N TSH TEM SLV 00230 720PR TRH+ 0.0T0+ 0.2 0.74 16 SAI 2 H TEH TSH SLV 00022 720PR TRH+ 0.1T0+ 0.2 3.45 17 SAI 2 17 31 BUH+ 0.7 00135 0.46 33 VOL 7 H TEM STM PLG 00073 610PR WCH- 0.1T0+ 0.2 4.44 11 VOL P3 00132 5.17 8 SWI P3 H BUM STH PLG 00244 610PR WCH- 0.2T0+ 0.3 5.99 13 VOL P3 00134 3.98 7 VOL P3 l 21 31 M TEM TSH SLV 00023 720PR TRH+ 0.1T 0+ 0.2 1.74 16 SA! 2 -
34 31 M TEM TSH F*1 00039 720PR 1BM- 1.2TO- 1.1 3.58 12 MAI 2 00050 2.41 9 MAI 2 43 31 01h+ 0.1 00056 0.46 148 APC P1 H 01H 01H PLG 00110 T20PR 01H- 0.2T0+ 0.3 0.14 114 MAI 2 00009 1.01 115 DSI P1 03H+ 0.1 00092 0.33 103 VOL 2 03H- 0.0 00056 0.34 144 APC P1 H 03H 03H PLG 00110 T20PR 03H- 0.270+ 0.1 0.15 130 SVI 2 00009 0.25 117 DSI P1 4 32 H TEM TSH SLV 00019 720PR TRH+ 0.2T0+ 0.2 2.56 9 MAI 2
]
j . ,
CUMULATIVE INDICATIONS REPORT PRAIRIE ISLAND, UNIT 1 Generator: 12 Page: 4 of 16 i Leg......: Not and Cold togs Date: 12/05/97 i Release..: 2.2 Time: 16:37 mal, MCI,$AI, SCI,$VI,VOL for the entire length EXTENT CURRENT 01/96 ROW COL LEG BEG END REM REEL PROSE LOCATION VOLTS DEG % CH REEL VOLTS DEG % CH 8 32 H TEN TSH SLV 00019 720PR TRH+ 0.170+ 0.2 2.48 11 MAI 2 l l 10 32 H TEN TSH SLV 00020 720PR TRH+ 0.2T0+ 0.2 1.25 17 SA! 2 11 32 H TSH TEM SLV 00230 T20PR TRH+ 0.2T0+ 3.0 0.10 124 VOL 2 H TEN TSH SLV 00019 720PR TRH+ 0.3To+ 3.1 0.41 117 VOL 2 00053 0.51 112 MSN 2 {
H TSH TEM SLV 00230 720PR TRH+ 2.5T0+ 4.6 0.08 125 MAI 2 l 12 32 H TEH TSH SLV 00019 720PR TRH+ 0.2T0+ 0.2 1.86 9 SAI 2 i
1 14 32 H TEM TSH SLV 00020 720PR TRH+. 0.1T0+ 0.2 1.32 21 SAI 2 j TRH+ 2.0 00054 0.33 131 MSN 2 24 32 H TSH TEH SLV 00230 720PR TRH+ 3.1T0+ 5.9 0.24 117 MAI 2 00050 0.58 122 VOL 2 3
) H TEM TSH SLV 00039 720PR TRH+ 3.5To+ 3.7 0.68 112 VOL 2 00010 0.46 20 INR P1 H TEH TSH SLV 00039 720PR TRH+ 4.6To+ 4.8 0.56 109 VOL 2 00050 0.75 115 VOL 2 ,
l l 5 33 H TEM TSH SLV 00019 720PR TRH+ 0.1T0+ 0.3 3.27 19 MAI 2 j I
42 33 03H+ 0.3 00092 0.78 295 VOL 2 H 03H 03H PLG 00110 720PR 03H- 0.1T0+ 0.5 0.17 111 SVI 2 00056 0.59 108 APC P1 03H- 0.2 00092 0.60 129 VOL 2 H 03H 03H PLG 00110 720PR 03H- 0.5T0- 0.2 0.23 119 SVI 2 00009 0.93 132 DSI P1 8 34 H TEH TSH SLV 00017 720PR TRH+ 0.5T0+ 1.0 0.21 133 SAI 2 15 34 X TEM TSH SLV 00039 720PR TRH+ 0.1To+ 0.2 2.54 9 SAI 2 H TEN TSH SLV 00039 720PR TRH+ 6.9To+ 11.1 0.55 110 SAI 2 00053 0.32 298 MeM 2 H TEM TSH SLV 00039 720PR TSH+ 0.8T0+ 1.1 0.45 143 SAI 2 21 34 H TEH TSH SLV 00018 720PR TRH+ 2.5T0+ 4.9 0.33 133 MAI 2 H TEH TSH SLV 00018 720PR TRH+ 8.4TO+ 9.8 0.30 134 SAI 2 23 34 H TEN TSH SLV 00018 720PR TRH+ 0.0To+ 0.2 3.05 14 MAI 2 i
42 34 01H+ 0.0 00056 0.75 77 APC P1 i
' 01H+ 0.1 00092 0.08 129 VOL 2 H 01H 01H PLG 00119 720PR 01H- 0.1T0+ 0.2 0.13 131 SA! 2 00009 0.76 91 DSI P1 H 03N 03H PLG 00110 720PR 03H+ 0.1T0+ 0.3 0.16 60 SVI 2 00009 0.39 98 DSI P1
[
03H+ 0.2 00056 0.27 113 APC P1 03H* 0.2 00092 0.40 175 VOL 2 43 34 03H+ 0.1 00056 1.02 131 APC P1 03H+ 0.1 00092 0.41 78 VOL 2 H 03H 03H PLG 00110 T20PR 03H- 0.1To+ 0.3 0.28 99 SVI 2 00010 1.13 127 10 P1
! 4 35 H TEM TSH SLV 00018 720PR TRH+ 0.1T0+ 0.3 1.72 11 MAI 2 15 35 H TEH TSH SLV 00018 720PR TRH+ 0.1T0+ 0.2 1.23 15 SAI 2 l
l 0.1TO+ 0.2 2.23 11 MAI 2 ;
26 35 N TEN TSH SLV 00018 720PR TRH+
28 35 H TEM TSH SLV 00226 720PR 1BM- 0.7T0+ 2.1 0.25 149 MAI 2 H TEH TSH SLV 00226 720PR 1BM- 1.2TO- 1.1 0.29 19 SAI 2 H TEH TSH SLV 00018 720PR TRH+ 0.1To+ 0.2 3.42 15 MAI 2 44 35 03H- 0.2 00092 0.60 80 VOL 2 H 03H 03H PLG 00110 720PR 03H- 0.2T0+ 0.3 0.24 137 SV! 2 00009 0.68 120 19 P1 l 03H- 0.6 00056 0.85 131 APC P1 NSP
t '
l .
CUMULATIVE INDICATIONS REPERT PRAIRIE ISLAND, UNIT 1 Generators 12 Pages 5 of 16 Leg......: Not and Cold legs Date: 12/05/97 Reteese..: 2.2 Times 16:37 l MAI, MCI,SAI,5Cl,SVI,VOL for the entire tength
< EXTENT CURRENT 01/96 R0W COL LEG BEG END REM REEL PROBE LOCATION VOLTS DEG 1 CH REEL VOLTS DEG % CH 36 BUH STM PLG 00251 610PR WCH- 0.1T0+ 0.1 1.20 135 VOL P3 00023 0.37 129 SWI P3 3 H H TEM STM PLG 00075 610PR WCH- 0.1T0+ 0.1 0.60 81 VOL P3 00034 11.09 32 VOL P1 11 36 H TEM STN PLG 00108 610MR WCH- 0.1T0+ 0.1 0.35 144 VOL P3 H BUM STM PLC 00251 610PR WCH- 0.1T0+ 0.1 1.16 20 VOL P3 14 36 H TEM ETH PLG 00108 610MR WCH- 0.1T0+ 0.3 1.52 23 MCI P3 H BUM STH PLG 00244 610PR WCH- 0.1T0+ 0.3 1,82 19 MCI P3 15 36 H TEM STN PLG 00108 610MR WCH- 0.1T0+ 0.2 0.92 43 MCI P3 H BUH STM PLG 00244 610PR WCH- 0.2T0+ 0.3 1.05 41 MCI P3 2 37 N TEH TSH SLV 00041 720PR TRH+ 0.270+ 0.2 1.23 9 SAI 2 26 38 H TEM TSH SLV 00015 720PR TRH+ 0.1T0 0.2 2.44 9 MAI 2 TRH+ 1.3T0+ 5.1 00055 0.28 124 INR 2 37 38 H TEM TSH F*1 00018 720PR 1BM- 1.3To- 1.1 12.51 21 MAI 2 00056 2.42 11 MAI 2 39 c 07C OTC PLC 00084 720PR 07C+ 0.1T0+ 0.4 0.17 128 SV! 2 00009 0.68 140 OSI P1 12 07C+ 0.2 00054 0.15 88 VOL 2 29 39 H TEH TSH SLV 00226 720PR 1BH- 0,970+ 2.2 0.66 160 MAI 2 H TEH TSN SLV 00016 720PR TRH+ 0.1T0+ 0.2 1.97 18 MAI 2 33 39 H TEH TSH SLv 00226 720PR 1BM- 0.9T0+ 2.1 0.26 175 MA! 2 i H TEM TSH SLV 00016 720PR TRH+ 0.2T0+ 0.2 2.34 15 SA! 2 BUH+ 0.5 00034 37.02 6 VOL P1 13 40 00079 610PR WCH- 0.270+ 0.1 0.70 55 VOL P3 00025 0.82 43 SWI P3 M TEH STH PLG 00244 610PR WCH- 0.3T0+ 0.2 0.61 68 VOL P3 00032 0.57 19 VOL P3 H BUN STM PLG 40 TEH TSH SLV 00016 720PR TRH+ 0.1T0+ 0.1 2.71 9 MAI 2 21 H 27 40 M TEM TSH SLV 00226 720PR 1BH- 1.6T0+ 1.8 0.35 149 MAI 2 H TEM TSH SLV 00016 720PR TRH+ 0.1T0+ 0.2 2.74 12 MAI 2 41 BUM STN PLG 00251 610PR WCH- 0.1T0+ 0.2 0.80 13 VOL P3 00034 28.08 i VOL P1 3 M 00079 610PR WCH- 0.2T0+ 0.2 1.01 14 VOL P3 00025 1.29 16 SWI P3 H TEH STH PLG 00079 610PR WCH- 0.2T0+ 0.3 1.07 36 VOL P3 00024 0.92 28 VOL 3 8 41 H TEM STU PLG 00244 610PR WCH- 0.2T0+ 0.3 0.71 43 VOL P3 00034 35.66 10 VOL P1 H BUM STH PLG 00079 610PR WCH- 0.170+ 0.2 0.61 74 VOL P3 00024 0.44 45 SWI P3 10 41 H TEM STN PLG 00244 610PR WCH- 0.1T0+ 0.2 0.45 146 VOL P3 00034 16.35 5 VOL P1 H BUM STN PLG 14 41 H TEH TSH PLC 00015 720PR TSH+ 0.1T0+ 0.8 1.91 101 SAI 2 H 01H TSH PLG 00230 720PR TSH+ 0.1T0+ 1.4 0.92 95 MAI 2 H 01H TSH PLG 00230 720PR TSH- 0.5T0- 0.3 0.15 114 SAI 2 l
34 42 H TEM TSH SLV 00226 720PR 1BM- 0.3T0+ 1.4 0.13 32 MAI 2 l
M TEM TSH SLV 00015 720PR TRH+ 0.1T0+ 0.2 2.62 10 MAI 2 0.2T0+ 0.2 0.10 33 VOL P3 00025 0.83 26 VOL P3 4 43 H TEM STN PLG 00081 610PR WCH-0.2T0+ 0.2 1.90 28 VOL P3 00034 26.92 11 VOL P1 H BUM STN PLC 00244 610PR WCH-0.170+ 0.2 0.17 31 VOL P3 00025 0.56 29 VOL 3 to 43 H TEM STM PLG 00081 610PR WCH-0.2T0+ 0.3 1.14 34 VOL P3 00034 24.92 14 VOL P1 H BUh STM PLG 00244 610PR WCH-15 43 H TEM TSH SLV 00015 720PR TSH+ 0.370+ 0.4 0.75 155 SAI 2 1
NSP l
l
CUMULATIVE INDICATIONS REPORT PRAIRIE ISLAND, UNIT 1 Generator: 12 Pages 6 of 16 Leg......: Not and Cold legs Date: 12/05/97
. R tease..: 2.2 Times 16:37 I
MAI, MCI,$AI,SCl,SVI,VOL for the entire length l
EXTENT CURRENT 01/96 R0W COL LEG BEG END REM REEL PROBE LOCATION VOLTS DEG %' CH REEL VOLTS DEG % CH 43 H BUH STH PLG 00244 610PR WCH- 0.1To+ 0.3 0.48 76 VOL P3 00034 22.51 9 VOL P1 16 N TEM STN PLG 00081 610PR WCH- 0.1To+ 0.4 0.08 44 VOL P3 00025 0.54 28 VOL 3 8 44 02H+ 0.0 00058 0.73 119 APC P1 02H- 0.0 00096 0.37 93 VOL 2 H 02H 02H PLG 00113 620PR 02H- 0.2T0+ 0.2 0.14 105 SVI 2 00044 0.74 140 1 P1 13 44 H TEM STN PLG 00108 610MR WCH- 0.1T0+ 0.1 0.37 89 SCI P3 H BUH STM PLG 00244 610PR WCH- 0.1T0+ 0.1 0.37 111 SCI P3 33 44 H TEH TSH SLV 00226 720PR 1BH- 0.8To* 2.0 0.41 149 MAI 2 H TEM TSH SLV 00226 720PR 1BH- 1.3T0- 1.2 0.56 20 SAI 2 H TEM TSH SLV 00013 720PR TRH+ 0.1T0+ 0.2 4.76 10 MAI 2 6 45 H TEM STH PLC 00111 610MR WCH- 0.1T0+ 0.1 2.10 31 SCI P3 00132 1.02 34 SWI P3 00244 610PR WCH- 0.1T0+ 0.2 4.20 23 SCI P3 l H BUH STH PLG 9 45 N TEH TSH SLV 00095 720PR TRH+ 0.0T0+ 0.1 2.18 15 MAI 2 16 45 N TEH TSH SLV 00027 720PR TRH+ 0.170+ 0.2 2.56 18 SAI 2 1 46 C 07H 07C PLG 00023 680PR 07H+ 3.7T0+ 3.9 2.53 23 SA! 2 H 07C 07H PLC 00233 680PR 07H+ 3.7T0+ 4.0 0.57 29 SA! 2 3 46 H TEH STH PLG 00093 610PR WCh- 0.1T0+ 0.2 2.89 11 VOL P3 00136 2.33 33 SWI P3 H BUM STH PLG 00244 610PR WCH- 0.1T0+ 0.2 2.75 30 VOL P3 00137 2.48 11 VOL P3 12 46 H TEH TSH SLv 00027 720PR TRH+ 0.2T0+ 0.3 0.66 21 SA! 2 46 TRH+ 2.3 00060 0.47 118 MBM 2 17 H TEM TSH SLV 00026 720PR TRH+ 3.4T0+ 3.9 0.59 103 SAI 2 00015 0.33 158 UDI P1 TRH+ 3.5 00060 0.52 91 MBM 2 26 46 H TEM TSH SLV 00026 720PR TRH+ 0.170+ 0.2 2.19 10 MAI 2 31 46 H TEM TSH F*1 0022' 720PR 1BH- 1.2T0- 1.1 1.25 18 SAI 2 H TEH TSH F'1 00027 720PR TRH+ 0.1T0+ 0.3 2.89 16 SA! 2 34 46 H TEM TSH SLV 00226 720PR 1BM- 0.3T0+ 2.1 0.55 127 MAI 2 i H TEH TSH SLV 00026 720PR TRH+ 0.170+ 0.2 2.45 14 SA! 2 l 36 46 H TEM TSH SLV 00226 720PR 1BM+ 1.270+ 1.9 0.30 169 MA! 2 H TEM TSH SLV 00026 720PR TRH+ 0.170+ 0.2 1.82 2 MA! 2 I
3 47 H TEM TSH SLV 00095 720PR TRH+ 3.2To+ 5.0 0.37 120 MAI 2 00244 610PR WCH- 0.3T0+ 0.2 0.40 45 VOL P3 00034 38.86 8 VOL P1 4 47 H BUM STH PLG 00093 610PR WCH- 0.3T0- 0.0 0.82 70 VOL P3 00026 0.52 1 VOL P3 H TEM STH PLG 11 47 H TEM TSH SLV 00029 720PR TRH+ 0.170+ 0.2 4.84 21 MAI 2 H TEM TSH SLV 00029 720PR TRH+ 4.0T0+ 4.2 0.30 141 SA! 2 H TEM TSH SLV 00029 720PR TRH+ 6.0T0+ 6.2 0.15 140 SA! 2 15 47 H TEH TSH SLV 00026 720PR TSH+ 0.4T0+ 0.8 0.83 125 SAI 2 21 47 H TEH TSH SLV 00026 720PR TSH+ 0.6T0+ 0.7 0.45 115 SAI 2 l
00026 720PR TSH+ 0.270+ 0.5 0.34 117 SA! 2 l 22j47 H TEM TSH SLV l
. e l CUMULATIVE INDICATIONS REPORT l PRAIRIE ISLAND, UNIT 1 Generator 12 -Page 7 of 16 l Leg...... Not and Cold legs Date: 12/05/97 Release..: 2.2 Time: 16:37 MAI, MCI,$AI,5CI,SVI,VOL for the entire length l
l EXTENT CURRENT 01/96 R0W COL LEG BEG END REM REEL PROBE LOCATION VOLTS DEG 1 CH REEL VOLTS DEG % CH l
l l 24 47 H TSH TEH SLV 00230 720PR TRH+ 4.3T0+ 9.2 0.50 113 SAI 2 H TEM TSH SLV 00026 720PR TRH+ 4.8T0+ 8.3 1.20 118 SAI 2 l 27 47 N ISH TEH SLV 00230 720PR TRH+ 0.0T0+ 0.1 0.55 22 SAI 2 H TEM TSH SLV 00026 720PR TRH+ 0.1T0+ 0.1 5.10 17 SAI 2 H TSH TEM SLV 00230 720PR TRH+ 3.3T0+ 5.9 0.18 129 MAI 2 31 47 N TEM TSH F*1 00026 720PR TRH+ 0.1T0+ 0.1 3.26 13 MAI 2 32 47 N TEN TSH F*1 00026 720PR TRH+ 0.1T0+ 0.2 4.10 16 MAI 2 42 47 N TEN TSH PLG 00057 720PR TSH+ 0.3T0+ 0.7 0.76 39 SA! 2 H TSH TSH PLG 00109 720MR TSH+ 0.3T0+ 0.7 1.32 90 SAI 2 H 01H TSH PLG 00230 720PR TSH+ 0.4T0+ 0.8 0.18 38 SAI 2 6 48 H TEN TSH PLG 00095 720PR TRH+ 0.1T0+ 0.2 2.13 16 SAI 2 8 48 H TEM STH PLG 00093 610PR WCH- 0.2T0+ 0.2 1.02 36 VOL P3 00026 0.38 62 VOL P3 H STN TEN PLG 00212 610PR WCH- 0,2T0+ 0.3 0.64 58 VOL P3 00034 14.64 16 VOL P1 9 48 H TEM TSH SLV 00095 720PR TRH+ 0.1T0+ 0.2 1.29 11 SAI 2 16 48 H TEH TSH SLV 00029 720PR TRH+ 0.1T0+ 0.2 1.69 13 MAI 2 17 48 H TEM TSH PLG 00028 720PR TRH+ 0.1T0+ 0.1 3.42 9 MAI 2 H 01H TSH PLG 00230 720PR TSH+ 0.0T0+ 1.0 1.13 84 MAI 2 00059 0.80 126 VOL 2 H TEM TSH PLG 00028 720PR TSH+ 0.1T0+ 0.6 1.22 128 SAI 2 00015 1.95 43 lHR P1 42 48 H 01H TSH PLG 00230 720PR TSH+ 0.4T0+ 0.6 0.10 69 VOL 2 H TEH TSH PLC 00029 720PR TSH+ 0.5T0+ 0.7 0.32 74 VOL 2 H TSH TSH PLG 00109 720MR TSH+ 0.5T0+ 0.8 1.32 62 VOL 2 3 49 H TEH TSH SLV 00095 720PR TRH+ 0.1T0+ 0.2 3.29 22 SAI 2 10 49 H TEM TSH SLV 00095 720PR TRH+ 1.8T0+ 3.8 0.39 134 MAI 2 20 49 H TEH TSH SLV 00028 720PR TRH+ 0.1T0+ 0.2 2.31 15 SAI 2 34 49 H TEM TSH SLV 00226 720PR 18H- 0.7T0+ 1.9 0.16 165 MAI 2 H TEH TSH SLV 00226 720PR 1BH- 1.1TO- 1.1 0.40 18 SAI 2 H TEM TSH SLV 00028 720PR TRH+ 0.1T0+ 0.3 3.90 15 MAI 2 14 50 H BUH STM PLG 00244 610*R WCH- 0.2T0+ 0.2 1.43 28 VOL P3 00034 18.94 9 VOL P1 M TEM STH PLG 00067 610PR WCH- 0.2T0+ 0.3 1.39 30 VOL 4 00018 0.59 40 VOL 3 16 50 N TEM STH SLV 00029 720PR TRH+ 0.1T0+ 0.2 1.92 15 SAI 2 H TEH TSH SLY 00029 720PR TSH+ 0.4T0+ 0.6 0.65 86 SAI 2 00018 1.23 37 DTI P1 24 50 H TEM TSH SLV 00029 720PR TRH+ 0.1T0+ 0.2 2.48 10 SAI 2 28 50 M TEN TSH SLV 00029 720PR TRH+ 2.1T0+ 7.0 0.37 130 SAI 2 45 50 C 01C 01C PLG 00084 720PR 01C+ 0.1T0+ 0.4 0.51 142 VOL 2 00015 0.88 115 31 P1 14 51 M TEM TSH SLv 000.'? T20PR TRH+ 0.170+ 0.1 1.60 9 SAI 2 H TEM TSH SLV 00029 720PR TSH+ 0.1T0+ 0.4 0.27 104 MA! 2 16 51 M TEN TSH SLv 00028 720PR TRH+ 0.1T0+ 0.2 5.02 18 MAI 2 H TSH TEM SLV 00230 720PR TRH+ 2.7T0+ 0.3 1.38 21 MAI 2 H TSH TEH SLV 00230 720PR TRH+ 9.0T0+ 9.9 0.09 120 SA! 2 NSP l
CUNULATIVE INDICATIONS REPORT PRAIRIE ISLAND, UNIT 1 Generators 12 Page: 8 of 16 Leg......: Not and Cold less Date: 12/05/97 Release..: 2.2 Time: 16:37 MA!, MCI,$AI,5CI,$VI,VOL for the entfre length EXTENT CURRENT 01/96 ROW COL LEG BEG END REM REEL PROBE LOCATION VOLTS DEG % CN REEL VOLTS DEG % CN 17 51 N TEN TSN SLV 00029 720PR TRH+ 0.170+ 0.2 1.52 12 MAI 2 21 51 N TEN STN PLG 00067 610PR WCH- 0.2To+ 0.3 6.35 15 VOL P3 00018 0.97 28 VOL 3 N BUN STN PLG 00244 610PR WCH- 0.2T0+ 0.3 3.71 19 VOL P3 00034 35.31 15 VOL P1 25 51 N TEN TSN SLV 00029 720PR TRN+ 3.1T0+ 3.5 ').27 128 SAI 2 33 51 N TEN TSH SLV 00226 720PR 1BN- 0.8To+ 2.2 0.61 164 MAI 2 N TEN TSN SLV 00029 720PR TRN+ 0.1To+ 0.1 1.84 9 SA! 2 5 52 N TEN TSH SLV 00095 720PR TRH+ 3.4To+ 3.5 0.40 124 SAI 2 N TEN TSN SLV 00095 720PR TRN+ 4.1T0+ 4.3 0.41 131 SAI 2 N TEN TSH SLV 00095 720PR TRH+ 4.7T0+ 4.8 0.35 114 SAI 2 8 52 N TEN TSN SLV 00095 720PR TRN+ 0.1T0+ 0.2 2.89 14 SAI 2 10 52 N TEM STN PLG 00108 610MR WCH- 0.1T0+ 0.1 0.90 161 SCI P3 N BUN STN PLG 00244 610PR WCH- 0.1To+ 0.1 0.74 155 SCI P3 15 52 H TEN TSH SLV 00028 720PR TRH+ 0.0T0+ 0.1 4.27 8 SAI 2 22 52 N TEN TSH SLV 00029 720PR TRH+ 0.170+ 0.2 1.99 9 MAI 2 45 52 C 01C 01C PLG 00084 720PR 01C+ 0.1T0+ 0.3 0.17 131 VOL 2 14 53 N TEN TSN SLV 00031 720PR TRN+ 0.1To+ 0.2 1.80 8 SAI 2 16 53 H TEN TSH SLV 00031 720PR TRN+ 0.1T0+ 0.2 4.74 20 MAI 2 20 53 N TEN TSN SLV 00031 720PR TRH+ 0.1T0+ 0.2 2.27 12 MAI 2 21 53 N TEN TSN SLV 00030 720PR TRN+ 0.1T0+ 0.2 1.26 8 MAI 2 23 53 H TEN TSN SLV 00030 720PR (RH+ 0.170+ 0.2 1.88 10 SAI 2 27 53 N TEN TSN SLV 00226 720PR 1BN- 0.8T0+ 2.0 0.37 169 MAI 2 N TEN TSN SLV 00030 720PR TRN+ 0.1T0+ 0.2 2.92 3 MAI 2 29 53 H TEN TSN SLV 00226 720PR 1BN- 1.2T0+ 1.9 0.35 164 MAI 2 H TEN TSN SLV 00030 720PR TRH+ 0.1T0+ 0.2 2.68 10 MAI 2 44 53 01C+ 0.2 00055 0.33 276 VOL 2 C 01C 01C PLG 00084 720PR 01C+ 0.2T0+ 0.3 0.29 117 VOL 2 00018 0.39 97 DS! P1 4 54 N TEN TSN SLV 00095 720PR TRH+ 0.1To+ 0.2 1.24 24 MAI 2 14 54 N TEN TSN SLV 00030 720PR TRH+ 6.6To+ 7.7 0.40 137 SAI 2 32 54 N TEN TSN SLV 00226 720PR 1BN- 0.7To+ 1.9 0.59 166 MAI 2 H TEN TSH SLV 00031 T20PR TRH+ 0.1T0+ 0.2 1.79 7 MAI 2 43 54 C 01C 01C PLC 00084 720PR 01C+ 0.270+ 0.4 0.30 139 VOL 2 00017 0.14 90 DSI P1 01C+ 0.3 00054 0.10 134 VOL 2 44 54 C 01C 01C PLG 00084 720PR 01C+ 0.110+ 0.3 0.13 45 VOL 2 00018 0.41 66 DS! P1 01C+ 0.3 00054 0.05 82 VOL 2 5 55 N TEN TSN SLV 00095 720PR TRN- 0.0T0+ 0.1 2.49 14 MAI 2 I
l NSP
e e CUMULATIVE INDICATIONS REPORT PRAIRIE ISLAND, UNIT 1 t Generator 12 Page 9 of 16 Leg......: Not and cold lege Date 12/05/97 R: lease..: 2.2 Times 16:37
[ MAI, MCI,$AI,8CI,$VI,VOL for the entire length EXTENT CURRENT 01/%
R0W COL LEG BEG ENO REM REEL PROSE LOCATION VOLTS DEG % CH REEL VOLTS DEG' % CH 6 55 SUH+ 0.9 00145 0.78 18 VOL 7 H TEM STM PLG 00094 610PR WCH- 0.170+ 0.2 0.75 138 VOL P3 00141 1.41 27 SWI P3 H GUN STM PLG 00244 610PR WCH- 0.1T0+ 0.3 0.64 93 VOL P3 00143 0.82 19 VOL P3 l
12 55 H TEM STH PLL 00067 610PR WCH- 0.170+ 0.3 2.03 60 VOL P3 00141 1.17 39 SWI P3 H BUH STN PLG 00244 610PR WCH- 0.2T0+ 0.3 1.67 51 VOL P3 00143 0.70 41 VOL P3 16 55 H TEM TSH SLV 00030 720PR TRH+ 0.1T0+ 0.2 2.20 9 MAI 2 28 55 H TEM TSH SLV 00226 720PR 1BH- 0.6T0+ 2.0 0.23 145 MAI 2 H TEN TSH SLV 00030 720PR TRH+ 0.1T0+ 0.2 1.66 13 MAI 2 44 55 H 01H 01H PLG 00115 720PR 01H+ 0.1T0+ 0.3 0.15 75 SVI 2 00020 0.31 99 DSI P1 01P+ 0.2 00056 0.30 115 APC P1 01H- 0.1 00092 0.31 60 VOL 2 45 55 01C+ 0.2 00054 0.11 117 VOL 2 C 01C 01C PLG 00084 720PR 01C+ 0.270+ 0.4 0.28 91 VOL 2 00020 0.45 til DSI P1 3 56 H TEM STM PLG 00067 610PR WCH- 0.1T0+ 0.2 3.46 357 VOL P3 00018 1.08 171 INR 3 H SUN STH PLG 00244 610PR WCH- 0.1T0+ 0.2 1.25 19 VOL P3 00034 26.61 11 VOL P1 l
12 56 H TEM TSH SLV 00031 720PR TRH+ 0.1T0+ 0.2 1.80 14 SAI 2 16 56 H TEM TSH SLV 00031 720PR TRH+ 0.1T0+ 0.2 1.70 11 MAI 2 31 56 H TEN TSH SLV 00226 720PR 1BN+ 0.210+ 2.1 0.60 126 MAI 2 H TEM TSH SLV 00030 720PR TRH+ 0.1T0+ 0.2 1.78 8 MAI 2
&4 56 C 01C 01C PLG 00084 720PR 01C+ 0.1T0+ 0.3 0.11 101 VOL 2 00019 0.80 117 DSI P1 01C+ 0.3 00054 0.08 100 VOL 2 45 56 02H+ 0.2 00056 0.71 115 APC P1 H 02H 02H PLG 00115 720PR 02H- 0.170+ 0.4 0.23 70 SVI 2 00020 0.81 122 DSI P1 02H- 0.2 00092 0.71 82 VOL 2 3 57 H TEH TSH SLV 00033 720PR TRH+ 0.1T0+ 0.2 0.92 12 SA! 2 6 57 H TEH TSH SLV 00057 720PR TRH+ 0.1T0+ 0.1 1.90 15 SAI 2 H TEM TSH SLV 00057 720PR TRH+ 1.7T0+ 2.7 0.23 126 SAI 2 8 57 H TEM STM PLG 00067 610PR WCH- 0.2T0+ 0.2 1.04 44 VOL P3 00018 0.95 162 VOL 3 H BUH STH PLG 00244 610PR WCH- 0.3T0+ 0.2 1.21 29 VOL P3 00034 37.42 6 VOL P1 19 57 N TEM TSH SLV 00032 720PR TRH+ 0.1T0+ 0.2 2.05 10 MAI 2 20 57 H TEM TSH SLV 00033 720PR TRH+ 0.1T0+ 0.2 1.41 8 SA! 2 32 57 H TEM TSH SLV 00226 720PR 1BH+ 0.8T0+ 1.6 0.23 172 MAI 2 H TEH TSH SLV 00030 720PR TRH+ 0.1T0+ 0.2 2.82 11 MAI 2 37 57 H TEM TSH SLV 00226 720PR 1BM+ 0.0T0+ 1.4 0.12 13 MA! 2 H TEN TSH SLV 00031 T20PR TRH+ 0.1T0+ 0.2 3.83 13 SAI 2 ,
l 14 58 H TEH TSH SLV 00034 720PR TRH+ 0.1T0+ 0.2 2.89 14 MAI 2 l
2 59 H TEM TSH SLV 00033 720PR TRH+ 4.3T0+ 5.1 0.33 132 SA! 2 j 13 59 H TEM TSH SLV 00034 720PR TRH+ 0.6T0+ 5.4 0.42 127 SA! 2 1
NSP l
a e l
CUMULATIVE INDICATIONS REPORT PRAIRIE !$ LAND, UNIT 1 Generator 12 Page: 10 of 16 Leg......: Not and Cold legs Date: 12/05/97 Reteese..: 2.2 Time: 16:37 MA!, MCI,$AI, SCI,SVI,VOL for the entire length EXTENT CURRENT 01/%
R0W COL LEG BEG END REM REEL pro 8E LOCATION VOLTS DEG % CH REEL VOLTS DEG % CH 14 59 N TEN TSH SLV 00033 720PR TRH+ 0.170+ 0.2 1.99 8 MAI 2 20 59 N TEM TSH SLV OA34 720PR TRN+ 0.1T0+ 0.2 1.45 14 SAI 2 24 59 H TEN TSH SLV 00034 720PR TRN+ 0.1T0+ 0.3 1.92 12 MAI 2 29 59 N TEN TSH SLV 00226 720PR 1BN- 0.7T0+ 2.0 0.58 171 MAI 2 N TEN TSN SLV 00033 720PR TRH+ 0.1T0+ 0.2 2.45 12 MAI 2 00024 28.11 183 DRI P1 43 59 01H+ 0.1 00056 1.47 119 APC P1 N 01H 01H PLG 00115 720PR 01H+ 0.1T0+ 0.4 0.23 91 SV1 2 00024 1.45 12ft 19 P1 01H- 0.2 00092 0.57 97 VOL 2 44 59 N 01H TSN PLG 00230 720PR 01H+ 0.2T0+ 0.3 0.10 133 SV! 2 00056 0.74 66 APC P1 Oth+ 0.3 00092 0.17 147 VOL 2 N 01H TSH PLG 00115 720PR 01H+ 0.3T0+ 0.3 0.18 133 SVI 2 00023 0.63 82 OSI P1 N 01H TSH PLG 00115 720PR TSH+ 13.5T0+ 13.3 0.65 108 VOL 2 00023 0.49 156 25 1 N 01N TSH PLC 00230 720PR TSH+ 13.5T0+ 13.6 0.16 102 VOL 2 9 60 N TEN TSN SLV 00033 720PR TRH+ 0.1T0+ 0.2 2.27 5 MAI 2 10 60 H TEN TSH SLV 00034 720PR TRH+ 0.8T0+ 2.7 0.21 134 MAI 2 25 60 N TEN TSH SLv 00034 720PR TRH+ 0.1T0+ 0.2 3.38 9 SA1 2 44 60 01H+ 0.2 00056 1.10 112 APC P1 N 01H 01H PLC 00115 720PR 01H+ 0.270* 0.3 0.16 100 SV! 2 00023 1.04 110 OSI P1 01H- 0.3 00092 0.50 131 VOL 2 7 61 N TEM ST N PLG 00067 610PR WCH- 0.170+ 0.2 4.68 16 VOL P3 00142 2.27 27 SWI P3 H BUH STM PLG 00244 610PR WCH- 0.1T0+ 0.3 2.65 24 VOL P3 00144 1.56 20 VOL P3 9 61 M TEH TSH SLV 00034 720PR TRH+ 0.1T0+ 0.2 3.21 6 SAI 2 11 61 N TEM TSH SLV 00034 720PR TRH+ 0.5T0+ 8.1 0.45 122 MAI 2 16 61 H TEM TSH SLV 00033 720PR TRH+ 0.170+ 0.2 1.59 15 MAI 2 41 61 N TEH TSH PLG 00038 720PR TSH+ 0.1T0+ 0.2 0.41 95 VOL 2 ;
42 61 01C+ 0.2 00054 0.11 138 VOL 2 C 01C 01C PLG 00084 720PR 01C+ 0.2T0+ 0.3 0.22 226 VOL 2 00024 0.43 106 DSI P1 j
9 62 H TEN TSH SLV 00036 720PR TRH+ 0.0T0+ 0.1 1.64 9 SAI 2 1 M TEN TSH SLV 00036 720PR TRH+ 0.8T0+ 5.8 0.41 120 SA! 2 l
10 62 H TEM TSH SLV 00035 720PR TRH+ 0.6T0+ 5.1 0.46 127 MAI 2 12 62 H TEM TSH SLV 00035 720PR TRH+ 1.170+ 6.9 0.24 109 MAI 2 14 62 N TEM TSH SLV 00035 720PR TRH+ 4.2T0+ 8.7 0.35 131 SAI 2 33 62 H TEN TSH SLV 00226 720PR 1BN- 0.8T0+ 2.1 0.60 119 MAI 2 N TEN TSH SLV 00035 720PR TRH+ 0.2T0+ 0.3 1.34 8 MAI 2 42 62 02H+ 0.1 00092 0.98 111 VOL 2 02H- 0.1 00056 0.36 144 APC P1 H 02H 02H PLG 00115 720PR 02H- 0.270+ 0.0 0.28 95 SVI 2 00023 0.27 122 OSI P1 MSF
. e i
CUMULATIVE INDICATIONS REPORT i PRA!RIE ISLAND, UNIT 1 Generator: 12 Page 11 of 16 i Leg......: Not and cold legs Date: 12/05/97 Reteese..: 2.2 Time: 16:37 l mal,MCl,SAI, SCI,SVI,VOL for the entire length l EXTENT CURRENT 01/%
REEL PROBE LOCATION VOLTS DEG % CH REEL VOLTS DEG % CH ROW COL LEG BEG END REM 2 63 H TEH TSH SLV 00036 720PR TRH+ 0.270+ 0.3 2.16 9 SAI 2 H TEM TSH SLV 00036 720PR TRH+ 1.5T0+ 1.8 0.36 138 SAI 2 13 63 H TEM STN PLG 00108 610MR WCH- 0.2T0+ 0.0 1.09 58 SCI P3 H BUM STM PLG 00244 610PR WCH- 0.2T0+ 0.0 2.63 20 SCI P3 15 63 H TEN TSH SLV 00035 720PE TRM- 0.1T0+ 0.1 2.12 11 SAI 2 63 TEH TSH SLV 00035 720PR TRH+ 0.0T0+ 0.2 2.20 13 MAI 2 00069 INF 1 23 H 32 63 H TEM TSH SLV 00226 720PR 1BM- 0.8T0+ 2.0 0.26 146 MAI 2 l H TEH TSH SLV 00036 720PR TRH+ 0.1T0+ 0.1 2.91 12 SAI 2 36 63 H TEH TSH SLV 00036 720PR TSH+ 0.0T0+ 0.2 0.35 116 VOL 2 00070 0.39 117 VOL 2 3 64 H TEH TSH SLV 00036 720PR TRH+ 0.5T0+ 5.9 0.53 137 MAI 2 00070 1.45 286 PVN 1 l
8 64 H TEH TSH SLV 00035 720PR TRH+ 0.1T0+ 0.1 0.98 10 SAI 2 00070 3.01 19 PVN 1 /
13 64 H TEN TSH SLV 00035 720PR TRH+ 0.0T0+ 0.1 2.50 13 MAI 2 16 64 H TEM STH PLG 00069 610PR WCH- 0.2T0+ 0.1 1.49 34 VOL P3 00018 0.81 24 VOL 3 H BUM STN PLG 00244 610PR WCH- 0.3T0+ 0.2 1.39 47 VOL P3 00034 29.88 8 VOL P1 19 64 H TEH TSH SLV 00036 720PR TRH+ 3.7T0+ 8.5 0.20 130 MAI 2 24 64 H TEH TSH SLV 00035 720PR TRH+ 0.1T0+ 0.2 2.92 12 SAI 2 25 64 H TEM TSH SLV 00036 720PR TRN- 0.0f 0+ 0.1 3.20 14 MAI 2 !
)
42 64 H 01H 01H PLG 00117 720PR 01H+ 0.1T0+ 0.4 0.09 97 SV! 2 4 65 H TEH TSH SLV 00035 720PR TRH+ 0.0T0+ 0.2 2.62 9 MAI 2 6 65 H TEM TSH SLV 00035 720PR TRH+ 0.0T0+ 0.2 2.16 15 MA! 2 7 65 H TEM STH PLG 00069 610P!! WCH- 0.2T0+ 0.1 1.09 160 VOL P3 00018 0.50 172 VOL 3 H BUM STM PLG 00244 610PR WCH- 0.2T0+ 0.1 0.36 84 VOL P3 00034 51.45 4 VOL P1 i 8 65 H TEM TSH SLV 00035 720PR TRH+ 1.7T0+ 2.2 0.31 74 MAI 2 l
l 15 65 H TEM TSH SLV 00035 720PR TRH+ 0.0T0+ 0.2 2.30 14 MAI 2 BUH+ 0.4 00034 37.58 4 VOL P1 17 65 N TEH STM PLC 00069 610PP WCH- 0.2T0+ 0.1 0.79 163 VOL P3 00018 0.69 142 VOL 3 H BUM STM PLG 00244 610PR WCH- 0.2T0+ 0.1 0.43 150 VOL P3 00035 0.60 26 VOL 2 19 65 H TEM TSH SLV 00036 720PR TRH+ 5.5T0+ 6.0 0.53 138 SAI 2 1 66 H TEN TSH PLG 00038 720PR TRH+ 0.6T0+ 1.9 0.40 135 MAI 2 00069 610PR WCH- 0.210+ 0.1 0.62 152 VOL P3 00018 0.23 91 SWI P3 6 66 H TEM STH PLG 4 VOL P1 H BUM STM PLG 00244 610PR WCH- 0.2T0+ 0.2 1.66 20 VOL P3 00034 27.04 7 66 H TEH TSH SLV 00037 720PR TRH+ 0.170+ 0.2 2.48 12 SAI 2 8 66 H TEH TSH SLV 00038 720PR TRH+ 0.170+ 0.2 2.13 7 MAI 2 6 67 H TEH TSH SLV 00038 720PR TRH+ 0.770+ 3.3 0.39 128 MAI 2 NSP
\
I
,4 i CUMULATIVE INDICATIONS REPORT PRAIRIE ISLAND, UNIT 1 Generators 12 .
Page: 12 of 16 Leg......: Not and Cold less Date: 12/05/97 Reteese..: 2.2 Time: 16:37 mal, MCI,$AI,5CI,$VI,VOL for the entire length EXTENT CURRENT 01/96 R0W COL LEG BEG END REM REEL PROSE LOCATION VOLTS DEG 1 CH REEL VOLTS DEG % CH 9 67 N TEH TSH SLV 00038 720PR TRH+ 1.5T0+ 5.1 0.18 126 MAI 2 l
13 67 H TEM TSH SLV 00038 720PR TRH+ 0.0T0+ 0.1 3.25 11 MAI 2 H TEM STM SLV 00247 610PR WCH+ 0.2T0+ 0.3 0.21 94 VOL 4 H BUM STM SLV 00252 610PR WCH+ 0.2T0+ 0.3 0.63 63 VOL 4 20 67 N TEH TSH SLV 00038 720PR TRH+ 0.6T0+ 4.9 0.48 122 MAI 2 1
, 23 67 H TEM STN PLG 00069 610PR WCH- 0.3T0+ 0.1 1.50 29 VOL P3 00018 1.80 30 VOL 3 H BUM STN PLG 00244 610PR WCH- 0.3T0+ 0.1 1.25 31 VOL P3 00034 26.29 12 VOL P1 l
25 67 H TEM TSH SLV 00037 720PR TRH+ 0.1T0+ 0.2 2.03 17 SAI 2 l
31 67 H TEM TSH SLV 00037 720PR TRH+ 0.1T0+ 4.1 0.29 144 SAI 2 38 67 C 01C 01C PLG 00084 720PR 01C+ 0.270+ 0.5 0.60 258 VOL 2 00023 0.61 76 DSI P1 1 01C+ 0.3 00054 0.17 127 VOL 2
- 40 67 C 01C 01C PLG 00084 720PR 01C+ 0.1T0+ 0.5 1.01 113 VOL 2 00023 0.56 124 DSI P1 01c+ 0.2 00054 0.31 112 VOL 2 l
i H 01H 01H PLC 09117 720PR 01H- 0.4TO- 0.1 0.06 94 Sv! 2 l l 7 68 BUH+ 0.5 00125 6.42 8 VOL 6
! 00126 6.64 7 7
> BUH+ 0.7 VOL
! H TEH STH PLG 00069 610PR WCH- 0.2T0+ 0.3 16.21 15 VOL P3 00124 12.11 14 SWI P3 i i
8 68 H TEH TSH SLV 00057 720PR TRH+ 0.1T0+ 0.2 1.19 to SAI 2 12 68 H TEM TSH SLV 00037 720PR TRH+ 0.0T0+ 0.1 1.76 10 SAI 2
- H TSH TEM SLV 00230 720PR TRH+ 0.0T0+ 0.2 0.43 16 SAI 2
[' H TSH TEM SLV 00230 720PR TRH+ 1.1T0+ 12.4 0.14 119 SAI 2 H TEH TSH SLV 00037 720PR TRH+ 1.2T0+ 10.8 0.34 89 SAI 2 23 68 H TEH TSH SLV 00037 720PR TRH+ 0.1T0+ 0.2 3.02 to MAI 2 4 69 H TEM TSH SLV 00038 720PR TRH+ 0.7T0+ 3.8 0.33 130 MAI 2 9 69 H TEH TSH SLV 00037 720PR TRH+ 0.1T0+ 0.1 0.08 45 SAI 2
' 14 70 N TEN TSH SLV 00043 720PR TRH+ 0.1T0+ 0.2 2.85 14 MAI 2 H TEH TSH SLV 00043 720PR TRH+ 4.6T0+ 4.7 0.35 133 SAI 2 15 70 N TEM TSH SLV 00042 720PR TRH+ 0.1T0+ 0.2 2.71 11 MAI 2 18 70 N TEM TSH SLV 00043 720PR TRH+ 0.1T0+ 0.2 1.43 18 SAI 2 73 70 H TEH TSH SLV 00043 720PR TRH+ 0.1T0+ 0.2 2.11 16 MAI 2 37 70 C 01C 01C PLG 00084 720PR 01C+ 0.1T0+ 0.5 1.09 115 VOL 2 00033 0.51 89 DSI P1 01C+ 0.3 00054 0.19 74 VOL 2 39 70 N 01H 01H PLG 00117 720PR 01H+ 0.1T0+ 0.4 0.22 105 SVI 2 00033 0.64 131 24 P1 01H+ 0.2 00056 0.69 135 APC P1 01H- 0.2 00092 0.83 94 VOL 2 I
4 71 H TEH TSH F*1 00043 720PR 1BH- 1.6To- 1.2 10.07 24 MAI 2 00073 4.84 3 MAI 2 l
10 71 N TEN TSH SLV 00042 720PR TRH+ 0.1T0+ 0.2 2.33 9 SAI 2 l
l NSP
- 5 CUMULATIVE INDICATIONS REPORT PRAIRIE ISLAND, UNIT 1 Generator: 12 .
Page: 13 of 16 Leg......: Hot and Cold legs Date 12/05/97 Reteese..: 2.2 Times 16:37 MAI, MCI,SAI, SCI,SVI,VOL for the entire tength
, EXTENT CURRENT 01/%
ROW COL LEG BEG END REM REEL PROSE LOCATION VOLTS DEG 1 CH REEL VOLTS DEG %' CH
! 4 72 H TEM TSH SLV 00042 720PR TRH+ 0.1T0+ 0.3 7.93 16 MAI 2 H TSH TEM SLV 00230 720PR TRM- 0.2T0+ 0.3 1.44 22 MAI 2
- 5 72 H TEH TSH SLV 00043 720PR TRH+ 0.1T0+ 0.2 1.78 16 MAI 2 8 72 H TEH TSH SLV 00042 720PR TRH+ 1.5T0+ 2.4 0.43 122 SAI 2 l 10 72 H TEM TSH SLV 00042 720PR TRH+ 0.1T0+ 0.3 4.79 11 SAI 2 1
l 15 72 H TEH TSH SLV 00043 720PR TRH+ 0.170+ 0.3 3.32 8 MAI 2 25 72 H TEM TSH SLV 00043 720PR TRH+ 0.6T0+ 5.7 0.37 145 SAI 2 38 72 H 01H 01H PLG 00117 720PR 01H+ 0.1To+ 0.3 0.13 71 SVI 2 00033 0.36 107 DSI P1 01H+ 0.3 00056 0.41 107 APC P1 01H- 0.1 00092 0.36 143 VOL 2 5 73 H TEM TSH SLV 00043 720PR TRH+ 0.1T0+ 0.2 2.81 17 MAI 2 12 73 H TEN TSH SLV 00045 720PR TRH+ 0.7To+ 7.4 0.22 131 SAI 2 16 73 H TEM TSH SLV 00045 720PR TRH+ 4.9TO+ 5.0 0.22 129 SA! 2 17 73 H TEM TSH SLV 00044 720PR TRH+ 1.4T0+ 2.0 0.34 127 SAI 2 26 73 H TEN TSH SLV 00045 720PR TRH+ 1.8T0+ 2.0 0.30 129 SAI 2 2 74 H TEM TSH SLV 00046 720PR TRH+ 0.4T0+ 1.5 0.31 129 SAI 2 4 74 H TEM TSH SLV 00046 720PR TRH+ 0.2T0+ 0.3 3.27 15 MAI 2 10 74 H TEH TSH SLV 00046 720PR TRH+ 0.1T0+ 0.2 1.01 17 MAI 2 l 33 74 H TEH TSH PLG 00045 720PR TRH+ 1.4T0+ 2.1 0.33 120 SAI 2 TRH+ 4.5 00073 0.52 169 INR 2 l
4 75 BUH+ 0.6 00145 4.49 4 VOL 7 H TEN STM PLG 00069 610PR WCH- 0.2T0+ 0.3 8.92 6 VOL P3 00142 6.89 9 SWI P3 H BUH STH PLG 00244 610PR WCH- 0.270+ 0.3 3.73 16 VOL P3 00144 4.30 3 VOL P3 11 75 H TEM TSH SLV 00045 720PR TRM- 0.0T0+ 0.0 2.26 18 SAI 2 13 75 H TEM TSH SLV 00045 720PR TRH+ 1.6TO+ 3.4 0.53 134 SAI 2 15 75 N TEH TSH SLV 00045 720PR TRH+ 0.1To+ 0.2 2.44 10 MAI 2 35 75 C 01C 01C PLG 00084 720PR 01C+ 0.2T0+ 0.5 0.55 144 VOL 2 36 75 H 03H 03H PLC 00117 720PR 03H+ 0.0T0+ 0.3 0.33 99 SVI 2 00033 0.60 133 19 P1 03H+ 0.1 00056 0.63 132 APC P1 03H- 0.2 00092 1.47 114 VOL 2 6 76 H TEN TSH SLV 00060 720PR TRH+ 0.1T0+ 0.2 2.30 19 MAI 2 8 76 H TEN TSH SLV 00045 720PR TRH+ 0.5T0+ 3.7 0.24 119 SAI 2 9 76 H TEH TSH SLV 00046 T20PR TRH+ 0.1T0+ 0.2 3.26 15 MAI 2 19 76 H TSH TEM SLV 00230 720PR TRH+ 7.2T0+ 11.2 0.22 125 SAI 2 H TEM TSH SLv 00046 720PR TRH+ 7.2T0+ 12.2 0.66 136 SAI 2 l
I~ l l.
i i f CUMULATIVE INDICATIONS REPORT PRAIRIE ISLAND, UNIT 1 ,
Generator: 12 Page: 14 of 16 Leg......: Not and Cold togs Date: 12/05/97 Release..: 2.2 Time: 16:37 MAI, MCI, TAI,$C1,SVI,VOL for the entire length EXTENT CURRENT 01/%
l ROW COL LEG BEG END REM REEL PROBE LOCATION VOLTS DEG % CH REEL VOLTS DEG % CH 23 76 H 03H 03H PLG 00117 720PR 03H- 0.1T0+ 0.2 0.13 131 Svl 2 32 76 H 03H 03H PLC 00122 720PR 03H- 0.1T0+ 0.2 0.21 120 SVI 2 33 76 03H+ 0.2 00056 0.63 131 1.PC P1 03H- 0.1 00092 0.60 93 VOL 2 H 03H 03H PLG 00117 720PR 03H- 0.1T0+ 0.3 0.15 93 SVI 2 00027 0.68 138 DSI P1 34 76 03H+ 0.1 00056 0.82 129 APC P1 N 03H 03H PLG 00117 720PR 03H- 0.0To+ 0.3 0.19 117 Syl 2 00033 0.80 123 OSI P1 03H- 0.1 00092 0.54 48 VOL 2 35 76 02H+ 0.2 00056 0.75 130 APC P1 H 02H 02H PLG 00117 720PR 02H- 0.0To+ 0.3 0.16 112 Syl 2 00033 0.86 136 11 P1 02H- 0.2 00092 0.51 97 VOL 2 2 77 H TSH TEM SLV 00230 720PR TRH+ 0.5T0+ 4.6 0.31 133 MAI 2 H TEH TSH SLV 00047 720PR TRH+ 0.6T0+ 3.2 1.03 139 MAI 2 5 77 H TEH TSH SLV 00047 720PR TRH+ 0.1To* 0.2 1.45 15 MAI 2 l
l 9 77 H TEM TSH SLV 00047 720PR TRH+ 0.1T0+ 0.2 1.77 7 MAI 2 11 77 H TEM TSH SLV 00047 720PR TRH+ 6.4T0+ 6.7 0.28 139 SAI 2 l
14 77 H TEH TSH SLV 00049 720PR TRH+ 0.1T0+ 0.2 2.11 13 MAI 2 19 77 H TEM TSH SLV 00047 720PR TRH+ 1.0T0+ 1.9 0.49 152 MAI 2 26 77 C TEC TSC PLG 00015 720PR TSC- 0.1To+ 0.3 1.93 99 VOL 2 33 77 H 03H 03H PLG 00117 720PR 03H+ 0.1T0+ 0.2 0.11 55 SVI 2 00027 0.66 143 19 P1 03H+ 0.2 00056 0.44 142 APC P1 03H- 0.2 00092 0.42 78 VOL 2 35 77 02H+ 0.2 00056 0.42 140 APC P1 02H- 0.1 00092 0.56 111 VOL 2 H 02H 02H PLG 00117 720PR 02H- 0.3T0+ 0.3 0.14 99 SVI 2 00033 0.45 137 8 P1 36 77 H 03H 03H PLG 00117 720PR 03H- 0.1T0+ 0.2 0.12 133 Sv! 2 H 03H 03H PLG 00122 720PR 03H- 0.1T0+ 0.2 0.12 133 Sv! 2 4 78 H TEM STM PLG 00108 610MR WCH- 0.170+ 0.1 1.12 13 SCI P3 H BUM STH PLC 00244 610PR WCH- 0.1T0+ 0.2 0.76 17 SCI P3 8 78 M TEM TSH SLV 00049 720PR TRH+ 3.4T0+ 3.9 0.34 134 SAI 2 26 78 C TEC TSC PLG 00025 720PR TSC- 0.1T0+ 0.2 2.17 106 VOL 2
, C 01C TSC PLG 00231 720PR TSC- 0.170+ 0.2 0.60 108 VOL 2 30 78 H 01H 01H PLG 00117 720PR 01H+ 0.2T0+ 0.4 0.15 132 SVI 2 H 03H 03H PLG 00117 720PR 03H+ 0.1T0+ 0.4 0.17 95 Svl 2 00033 0.43 134 DS! P1 03H+ 0.2 00057 0.50 139 APC P1 03H- 0.1 00092 0.57 75 VOL 2 5 79 H TEM TSH SLv 00059 720PR TRH+ 0.0T0+ 0.1 3.05 17 SAI 2 7 79 H TEN TSH SLV 00047 720PR TRH+ 0.1T0+ 0.2 3.44 13 SA! 2 14 79 H TEH TSH SLV 00049 720PR TRH+ 0.1T0+ 0.2 2.31 10 SAI 2 NBP l U- _ _ _ _ _ _ _
e t
) CUMULATIVE INDICATIONS REPORT PRA!RIE ISLAND, UNIT 1
} Page: 15 of 16 Generator 12 L eg . . . . . . : Not and Cold legs Date: 12/05/97 i Ratesse..: 2.2 Time: 16:37 MAI, MCI,SAI,5CI,SVI,VOL for the entire length EXTENT CURRENT 01/96 ROW COL LEG BEG END REM REEL PROSE LOCATIDH VOLTS DEG 1 CH REEL VOLTS DEG 1 CH l 32 79 02H+ 0.2 00057 0.55 144 APC P1 02H- 0.0 00092 0.33 60 VOL 2 H 02H 02H PLG 00117 720PR 02H- 0.1T0+ 0.3 0.16 131 SVI 2 00029 0.60 137 27 P1 f 33 79 03H+ 0.2 00057 0.61 140 APC P1
! H 03H 03H PLG 00117 720PR 03H- 0.0T0+ 0.3 0.17 116 SV! 2 00033 0.58 139 2 P1 l 03H- 0.1 00092 0.56 114 VOL 2 3 80 N OUM STM PLG 00244 610PR WCH- 0.2T0+ 0.2 1.19 34 VOL P3 H TEH STN PLG 00108 610MR WCH- 0.2T0+ 0.3 1.88 27 VOL P3 1 5 80 BUN + 0.3 00124 2.55 27 3WI P3 Bun + 0.6 00121 1.80 39 VOL 1 BUH+ 0.6 00125 2.66 16 VOL P2 BUH+ 0.7 00126 1.12 23 VOL 7 N TEM STM PLC 00070 610PR WCH- 0.270+ 0.3 3.25 28 VOL P3 00118 2.24 12 VOL P3 H BUH STH PLG 00244 610PR WCH- 0.2T0+ 0.3 1.54 52 VOL P3 00119 1.66 8 VOL 6 7 80 N TEH TSH SLV 00049 720PR TRH+ 0.170+ 0.2 3.02 16 MAI 2 l
12 80 H TEH TSH SLV 00047 720PR TRH+ 0.1T0+ 0.2 2.12 12 SA! 4 l 17 80 TRH+ 0.0T0+ 10.5 00076 2.84 157 INR 1 H TEH TSH SLV 00049 720PR TRH+ 3.3T 0+ 4.0 0.61 138 SAI 2 16 81 H TEH TSH SLV 00050 720PR TRH+ 2.970+ 3.7 0.58 147 SAI 2 26 81 C 06C 06C PLG 00084 T20PR 06C- 0.0T0+ 0.1 0.11 116 SVI 2 00029 0.58 154 9 P1 4 82 H TEN TSH SLV 00051 720PR TRH+ 0.0T0+ 0.2 2.18 17 MAI 2 10 82 H TEM TSH SLv 00051 720PR TRH+ 0.1T 0+ 0.2 1.63 14 MAI 2 5 83 H TEH TSH SLV 00051 720PR TRH+ 0.1T0+ 0.1 1.99 12 SAI 2 l 9 83 H TEM TSH SLV 00051 720PR TRH+ 0.0T0+ 0.1 1.75 7 SA! 2 10 84 H TEH TSH SLV 00054 720PR TRH+ 0.1T0+ 0.2 4.19 12 MAI 2 17 84 H TEN TSH SLV 00053 720PR TRH+ 2.0TD+ 2.5 0.34 117 SA! 2 00078 INF 11 85 H TEH TSH SLV 00054 720PR TRH+ 0.1T0+ 0.2 2.37 11 MAI 2 18 89 01H+ 0.2 00092 0.70 112 VOL 2 01H- 0.0 00057 0.57 134 APC P1 M 01H 01H PLG 00117 720PR 01H- 0.2TD+ 0.2 0.20 124 SVI 2 00029 0.51 135 29 P1 20 89 4 01H 01H PLG 00117 720PR 01H+ 0.1T0+ 0.5 0.25 122 SVI 2 00033 0.75 123 DSI P1 01H+ 0.3 00057 0.86 130 APC P1 01H- 0.3 00092 1.12 113 VOL 2 15 90 01C- 0.0 00055 0.91 273 VOL 2 C 01C 01C PLG 00084 720PR 01C- 0.2T0+ 0.3 1.24 97 VOL 2 00033 0.49 96 DSI P1 01H+ 0.0 00092 0.52 100 VOL 2 01H+ 0.1 00057 0.39 133 APC P1 H 01H 01H PLG 00117 720PR 01H- 0.2T0+ 0.2 0.11 121 SV! 2 00033 0.38 140 DSI P1 16 90 H 01H 01H PLG 00117 720PR 01H+ 0.170+ 0.4 0.14 133 SVI 2 00030 0.70 118 D$1 P1 01H+ 0.3 00057 0.73 122 APC P1 01H- 0.2 00092 0.46 120 VOL 2 I
NBP i
- f CUMULATIVE INDICATIONS REPORT PRAIRIE ISLAND, UNIT 1 Generator: 12 Page: 16 of 16 -
f Date: 12/05/97 !
Leg......: Hot and Cold legs Rsteese..: 2.2 Time: 16:37 mal, MCI,SA!, SCI,SVI,VOL for the entire length EXTENT CURRENT 01/96 ROW COL LEG SEG END REM REEL PROSE LOCATION VOLTS DEG 1 CH REEL VOLTS DEG %' CH 18 90 01C- 0.1 00054 0.11 103 VOL 2 l C 01C 01C PLG 00084 720PR 01C- 0.2T0+ 0.1 0.64 107 VOL 2 00030 0.26 113 DSI P1 1
12 91 C 01C 01C PLG 00084 720PR 01C- 0.0T0+ 0.2 0.25 140 VOL 2 01H+ 0.1 00057 0.84 146 APC P1 01H- 0.1 00092 0.40 81 VOL 2 H 01H 01H PLG 00117 720PR 01H- 0.1T0+ 0.2 0.12 127 SVI 2 00029 1.38 151 12 P1 15 91 H 01H 01H PLC 00117 720PR 01H+ 0.1T0+ 0.3 0.17 103 SV! 2 00033 0.68 142 DSI P1 01H+ 0.2 00057 0.77 141 APC P1 01H- 0.2 00092 0.79 121 VOL 2 16 91 M 02H 02H PLC 00117 720PR 02H- 0.1T0+ 0.3 0.28 131 SVI 2 H 03H 03H PLG 00117 720PR 03H+ 0.0T0+ 0.2 0.27 113 SVI 2 00030 0.50 118 DSI P1 03H+ 0.3 07057 0.50 115 APC P1 l 03H- 0.2 00092 0.71 til VOL 2 8 92 01H+ 0.1 00092 0.22 131 VOL 2 01H- 0.1 00090 0.21 112 APC P1 N 01H 01H PLG 00117 720PR 01H- 0.1T0+ 0.1 0.09 104 SVI 2 00011 0.22 117 DS! P1 l 10 92 01H+ 0.0 00092 0.53 111 VOL 2 i 01H+ 0.1 00057 0.52 117 APC P1 M 01H 01H PLG 00117 720PR 01H- 0.2T0+ 0.2 0.26 124 SVI 2 00011 0.41 113 DSI P1 13 92 01H+ 0.1 00057 0.20 135 APC P1 l
01H- 0.2 00092 0.27 108 VOL 2 H 01H 01H PLG 00117 720PR 01H- 0.3TO- 0.2 0.24 117 Svl 2 00033 0.31 92 DS! P1 8 93 01H+ 0.0 00092 0,46 149 VOL 2 l
01H- 0.2 00090 0.38 128 APC P1 N 01M 01H PLG 00117 720PR 01H- 0.270+ 0.1 0.13 125 SV! 2 00011 0.29 127 DS! P1 9 93 01H+ 0.0 00090 0.69 46 APC P1 01H+ 0.2 00092 0.40 % VOL 2 H 01H 01H PLG 00117 720PR 01H- 0.2T0+ 0.2 0.18 106 SV! 2 00010 0.49 69 DSI P1 l
NUMBER OF TUBES IN REPORT = 346 l NSP i
i
NORTHERN STATES POWER
SUMMARY
REPORT INSERVICE INSPECTION PRAIRIE ISLAND UNIT 1,1997 APPENDIX F LIST OF SNUBBER INSERVICE TESTING 1 Pages l
l e f l
SNUBBER TESTS Summary description of snubber visual inspection and functional testing for Prairie Island Unit 1, per Surveillance Procedure SP 1225 Rev 6. The examinations were conducted by Prairie Island site personnel.
SNUBBER FUNCTIONAL Pl # PI # TEST
1-RSlH-476 9704770 140 174 SAT 1-CWRH-80 9704770 133 603 SAT 1-AFWH-72 9704770 364 207 SAT 1-CCH-304 9704770 286 68 SAT l 1-CCH-373 9704770 278 38 SAT 1-CCH-376A 9704770 347 441 SAT 1-CCH-3768 9704770 276 37 SAT )
1-CCH-380 9704770 284 409 SAT 1-CCH-381 A 9704770 200 176 SAT 1-CCH-381 B 9704770 238 178 SAT 1-CCH-397 9704770 128 220 SAT 1-CCH-398A 9704770 294 243 SAT 1-CCH-3988 9704770 259 410 SAT 1-CWH-429 9704770 69 17 SAT 1-CWH-433 9704770 246 348 SAT 1 1-CWH-434 9704770 142 96 SAT l 9704770 143 89 SAT l 1-CWH-436 1-RCRH-23B 9704770 288 300 SAT 1-CWH-394 9704770 7 353 SAT j 1-MSH-104A 9704770 1350 609 SAT l 1-MSH-105A 9704770 550 555 SAT 1-RCRH-47A 97047 564 7924 SAT 1-RCRH-47B 9704770 565 564 SAT 11 S/G 01 9708661 SG 04 SG 20 SAT 12 S/G 01 9708662 SG 09 SG 04 SAT I
l 8 i NORTHERN STATES POWER
SUMMARY
REPORT INSERVICE INSPECTION PRAIRIE ISLAND UNIT 1,1997 APPENDIX G l
LIST OF 40 MONTH REACTOR VESSEL EXAMINATIONS 5Pages I
l l
- f NORTHERN STATES POWER CO.
! PRAIRIE ISLAND UNIT #1 REACTOR VESSEL 1997 EXAMINATIONS PROGRAM PLAN l
l I-Scope i Items and areas listed on the attached table are to be examined in accordance with the Prairi Island Unit 1 Plant Technical Specifications, the Prairie Island Unit i Outage Plan, the 1989 Edition of the ASME Code,Section XI, and the WesDyne International Position on USNRC Regulatory Guide 1,150 Revision 1.
All examinations will be conducted to the maximum extent practical with the access provided and within the limitation of component geometry.
Procedures Procedure NSP-ISI-154 Rev. O shall be used for remote mechanized examinations of the r vessel outlet nozzles.
Procedure NSP-ISI-54 Rev. O shall be used for manual examination of the reactor vessel flange-to-shell weld from the flange seal surface.
Procedure NSP-ISI-55 Rev. 0 shall be used for manual examination of the reactor vesl in-flange region. l 1
Examination Detailed parameters for the examination of each individual weld or area, including the locatio each scan in reference to vessel axis and datums, the number of scan lines, and incremental distances are defined I the reactor vessel scan coverage computer output data.
1 i
i i
C O
L S B R N O )
1 O T C, F, F, r
3, ( D, F, I C B, E, E, o 1, e C, E, T E D D 1 t o B D A L A 1 N
R F B E I R L
A C Y l 4- 4- 1 A
- 4-T -
E E V I
V F F V T R A A R R-N P S- S P E -
S P D S V V S I N R R N N T
/ NU W W C T TT EE LLL L)
R L) I L OC C N U UU LD * *
- T WTRW R L L L I
- 0O* OO '
GO C TR R O N
0 0 0 1 3 5 '5 C'4 C(
(5 T T R
T 6' 2 6' A M 6
4 5 45
- '5 '
5 1 1 4 4 4 7
9 9
1
. l O S l
CT a C N RI I 2 3 67 4 5 6 7 I 2 3 4 5 g 1
A N NNN NN NNN N F FFFF iL R
E
- O I EU TT S WI O N A
g A ENA lz e l
l z r e r n TAX AE z o z o z o a
/
N ALE XL ES N oB N oB NoB lF TS L S I NIES E RRS EI E AV M 1 I
)
- t s
l E / / 0 n 52 iR T P R T . R R 8 e#
R O I
/O 7 0 1 l
0 M M D
i 1
m-a D D L N 1 -
7 O T 1 5 5
- i#
g1 N C E 1 1 0
( L A W E
R d *5
/ " /
- e e r d 5 l s
r l 5 5 o o n n8 e le E 8 B* E 28 E0 h m o MN 8
2 0 R 85 B ". 5 e e2 S a x l UI O 2 IR8 0 f
a@ f a r el d E) l d
LT @ @ I- 2 - 2 Sd Sel @d pe e la c u u
UpW.
t OP le e le@ le@ l e le z z e fa n S
VR
/
I z
z o
lzz z z n z z
o n zW o e lzW o o rc r uM a d e
DC N o o io Ni r o Np Ne teC i
S( d L ES N Nt r t i t ip g l a e
E t t o t e Po t e P n a r D e t e
teP l t leP a S e
h W l t
u lt u
l u
lt u
t u ri s t u s t
r l
F T O O O O OF Oi F N
- OE I
TG AA A
/
A
/
3 RK I 2 N N BC l
l PA A
C I
E . /
A -
DT D -
D- F- J l
- - G-OA B B BI B 1 1
i e EXAMINATION INDICATION SUIGIARY RESULTS ITEM EXAMINED NI NRI RI REMARKS 7 X 2 8. 5* Ref. Tab. F& I 7 IR X 2 8. 5" Re f. Tab. I 15 DM X 28.5 Ref. Tab. I 1 X 28.5o Ref. Tab. I 10 X 208. 5* Ref. Tab. F& I 10 IR X 208.5* Ref. Tab. I 15 DM X 208. 5* Ref. Tab. I 1 X 208.5* Ref. Tab. I Flange to Upper X Ref. Tab. E Shell Weld 1, O to 180 )
Ligaments 1 thru 25 X Ref. Tab. E l I
l 1
i
l l
l INTERVAL 3 PERIOD 1 REACTOR VESSEL EXAMINATION l
SITE
SUMMARY
The Prairie Island Unit I reactor vessel was examined on November 1 and 2,1997. The scope of the intermediate reactor vessel included both outlet nozzle to shell welds, outlet nozzle safe end '
and first pipe welds and the nozzle bore segment of the inner radius examination volume.
Examinations were conducted exclusively from within the nozzle bores as the core barrel was in place.
Governing ciiteria for the exam included the Prairie Island Unit 1 Plant Technical Specifications, j the Prairie Island Unit 1 Outage Plan, the 1989 Edition of the ASME Code,Section XI and the WesDyne position on USNRC Regulatory Guide 1.150 Rev.1. Calibrations, examinations and analysis of processed data was witnessed by the Prairie Island Technical Staff, the Authorized Nuclear Inservice Inspector, and a representative of the USNRC. All examinations were conducted to the maximum extent practical with the access provided and within the limitations of component geometry.
AUTOMATED EXAMINATIONS Automated examinations were controlled by operating procedure NSP-ISI-154, Revision 0, Field Change 1. The procedure specified as a minimum,100% digital capture of the UT data, static and dynamic calibrations, and indication analysis in accordance with the 20% DAC criteria of the 1989 Code. Transducers were single element Longitudinal wave RTD design for the nozzle to shell examinations and dual element longitudinal wave RTD design for the safe end/ first pipe and inner radius examination. Information relative to the calibration blocks, beam angles and component identifications can be found in the f xamination Program Plan, considered part of the examination documentation package.
MANUAL EXAMINATIONS Manual examinations of the threads in flange and the flange to shell weld were performed on October 29,1997. The examinations were conducted from the top of the flange and the flange seal surface respectively in accordance with procedures NSP-ISI-54 Revision 0 and NSP-ISI-55 Revision 0, Field Change 1. Threads in flange I through 25 were examined and the flange to shell weld was examined from vessel 0 degrees to vessel 180 degrees.
RESULTS Automated examinations revealed a total of three recorded indications in the outlet nozzle to shell welds. The indications were conservatively bounded in the through-wall dimension to the 20%
i e r a I
DAC points. All three indications were found to be within the allowable limits of Section XI, Par.
3512-1. It should be noted that all three indications were probably considered non-recordable indications in the two previous inservice examinations, where the recording criteria was 50%
DAC. The safe-end/first pipe and inner radius examinations yielded no recordable indications.
Analysis of processed data was performed by qualified WesDyne Level III personnel. Manual examinations of the threads in flange and flange to shell weld yielded no recordable indications.
LIMITATIONS For automated examinations only accessible examination surface was the outlet nonle bores therefore only one examination direction is satisfied in the nonle to shell welds. The
- complimentary coverage of the 10,30 and 50 degree beams combined to interrogate 100% of the i nonle to shell weld and 99% of the surrounding HAZ examination volume. The safe-end/first pipe examinations were conducted without limitation or obstruction. The inner radius examination volume was limited by the core barrel mating surface however the great majority of this volume extends into the nonle bore and 91.5% coverage is estimated. Manual examinations of the threads in flange were not limited in any respect because the stud hole plugs are completely within the hole. For the flange to shell weld, the only accessible examination surface is the j l
flange seal surface therefore only one examination direction is satisfied. Coverage is estimated at
1 D. Turek WesDyne International 11-3-97 )
I
! 1 l l I
1 i l
i.
l l
l-l I
L _ _ -. ____ _______ _