Text
a f
Northern States Power Company Prairie Island Nuclear Generating Plant 1717 Wakonade Dr. East 4
Welch. Minnesota 55089 August 5,1999 Technical Specifications 6.7.A.3 I
US Nuclear Regulatory Commission Attn: Document Control Desk Washington, DC 20555 l
PRAIRIE ISLAND NUCLEAR GENERATING PLANT Docket Nos. 50-282 License Nos. DPR-42 50-306 DPR-60 Monthly Operating Report July 1999 Attached is the Monthly Operating Report for July,1999 for the Prairie Island Nuclear i
Generating Plant.
Joel P. Sorensen Site General Manager Prairie Island Nuclear Generating Plant c:
Regional Administrator-Ill, NRC NRR Project Manager, NRC NRC Resident inspector State of Minnesota - Steve Minn Attachment l$Y
\\
9908160043 970?31 PDR ADOCK 05000282 R
pag i
i
,l NRC MONTHLY REPORT PRINTED 8/3/1999 Pag 31 DOCKET NO.60-282 UNIT PRAIRIE ISLAND NO.1 DATE 8/3/1999 j
COMPLETED BY DALE DUGSTAD PHONE 651-388-1121-4376 NARRATIVE
SUMMARY
OF OPERATING EXPE llENCE MONTH: JULY 1999 During the month of July, Unit 1 was base loaded. TNre were no shutdowns or power reductions.
There are no other items to report.
i I
CURRENT CONTINUOUS OPERATING RUN OF 65 DAYS l
s NRC MONTHLY REPORT PRINTED 8/3/1939 Pagi 2 DOCKET NO. 50-282 UNIT PRAIRIE ISLAND NO.1 DATE 8/3/1999 COMPLETED BY DALE DUGSTAD PHONE 651388-1121-4376 OPERATING DATA REPORT OPERATING STATUS
- 1. UNIT NAME:
PRAIRIE ISLAND NO.1
- 2. REPORTING PERIOD:
JULY 1999
- 3. LICENSED THERMAL POWER (MWT): 1650
- 4. NAMEPLATE RATING (GROSS MWE): 593
- 5. DESIGN ELECTRICAL PATING (NET MWE): 536
- 6. MAXIMUM DEPENDABLE CAPACITY (GROSS MWE):
554
- 7. MAXIMUM DEPENDABLE CAPACITY (NET MWE):
522
- 8. IF CHANGES OCCUR IN CAPACITY RATINGS (ITEMS 3 - 7) SINCE LAST REPORT, GIVE REASON:
NONE
- 9. POWER LEVEL TO WHICH RESTRICTED, IF ANY (NET MWE): NONE
- 10. REASONS FOR RESTRICTIONS,IF ANY:
NONE THIS MONTH YR-TO-DATE CUMULATIVE
- 11. HOURS IN REPORTING PERIOD 744 5087 224615
- 12. NUMBER OF HOURS REACTOR CRITICAL 744.0 4028.3 192815.8
- 13. REACTOR RESERVE SHUTDOWN HOURS 0.0 0.0 5571.1
- 14. HOURS GENERATOR ON-LINE 744.0 3971.5 190910.2
- 15. UNIT RESERVE SHUTDOWN HOURS 0.0 0.0 0.0
- 16. GROSS THERMAL ENERGY GENERATED (MWH) 1226068 6449929 303680284
- 17. GROSS ELECTRICAL ENERGY GENERATED (MWH) 413370 2212050 100482020
- 18. NET ELECTRICAL ENERGY GENERATED (MWH) 389285 2088860 94532342
- 19. UNIT SERVICE FACTOR 100.0 78.1 85.0
- 20. UNIT AVAILABILITY FACTOR 100.0 78.1 85.0
- 21. UNIT CAPACITY FACTOR ( MDC NET) 100.2 78.7 83.2
- 22. UNIT CAPACITY FACTOR ( DER NET) 97.6 76.6 79.3
- 23. UNIT FORCED OUTAGE RATE 0.0 3.8 4.7
- 24. FORCED OUTAGE HOURS 0.0 156.6 9483.8 l
l 1
i
NRC MONTHLY REPORT PRINTED 8/3/1999 Page 3 DOCKET NO. 50-282 UNIT PRAIRIE ISLAND NO.1 DATE 8/3/1999 COMPLETED BY DALE DUGSTAD PHONE 651-388-1121-4376 UNIT SHUTDOWNS AND POWER REDUCTIONS MONTH: JULY 1999 DATE UNil TYPE HOURS REASON METHOD LER NUMBER SYSTEM COMPONENT 7/31/1999 1
N/A 0
I NOTES:
- None, l
HER REASON MgTHOD SYSTEM CODE F-FORCED A-EQUIPMENT FAILURE 1-MANUAL DRAFT IEEE STD S-SCHEDULED B-MAINTENANCE OR TEST 2-MANUAL TRIP C-REFUELING 3-AUTO TRIP D-REGULATORY RESTRICTION 4-CONTINUED E-OPERATOR TRAINING AND 5-REDUCED LOAD COMPONENT CODE LICENSE EXAMINATION 9-OTHER IEEE STD 803A-1983 F ADMINISTRATIVE G-OPERATIONAL ERROR H-OTHER
NRC MONTHLY REPORT PRINTED 8/3/1999 Pag) 4 DOCKET NO.60-306 UNIT PRAIRIE ISLAND NO. 2 DATE 8/3/1999 COMPLETED BY DALE DUGSTAD PHONE 651-388-1121-4376 NARRATIVE
SUMMARY
OF OPERATING EXPERIENCE MONTH: JULY 1999 During the month of July, Unit 2 was base loaded. There were no shutdowns or power reductions.
There are no other items to report.
4 CURRENT CONTINUOUS OPERATING RUN OF 174 DAYS
NRC MONTHLY REPORT PRINTED 8/3/1999 l
Pago5 DOCKET NO. 50-306 UNIT PRAIRIE ISLAND NO. 2 DATE 8/3/1999 COMPLETED BY DALE DUGSTAD PHONE 651-388-1121-4376 OPERAMNG DATA REPORT OPERATING STATUS
- 1. UNIT NAME:
PRAIRIEISLAND NO.2
- 2. REPORTING PERIOD:
JULY-1999
- 3. LICENSED THERMAL POWER (MWT): 1650
- 4. NAMEPLATE RATING (GROSS MWE):
593-
- 5. DESIGN ELECTRICAL RATING (NET MWE): 536
- 6. MAXIMUM DEPENDABLE CAPACITY (GROSS MWE):
554
- 7. MAXIMUM DEPENDABLE CAPACITY (NET MWE):
522
- 8. IF CHANGES OCCUR IN CAPACITY RATINGS (ITEMS 3 - 7) SINCE LAST REPORT, GIVE REASON:
NONE
- 9. POWER LEVEL TO WHICH RESTRICTED, IF ANY (NET MWE): NONE
- 10. REASONS FOR RESTRICTIONS,IF ANY:
NONE THIS MONTH YR-TO-DATE CUMULATIVE
- 11. HOURS IN REPORTING PERIOD 744 5087 215733
- 12. NUMBER OF HOURS REACTOR CRITICAL 744.0 5052.8 190374.9
- 13. REACTOR RESERVE SHUTDOWN HOURS 0.0 00 1516.1
]
- 14. HOURS GENERATOR ON-LINE 744.0 5017.9 188802.1
- 15. UNIT RESERVE SHUTDOWN HOURS 0.0 0.0 0.0
- 16. GROSS THERMAL ENERGY GENERATED (MWH) 1225790 8125179 301276260
- 17. GROSS ELECTRICAL ENERGY GENERATED (MWH) 412370 2773070 98809000
- 18. NET ELECTRICAL ENERGY GENERATED (M'NH) 388273 2624193 93410522
- 19. UNIT SERVICE FACTOR 100.0 98.6 87.5
- 20. UNIT AVAILABILITY FACTOR 100.0 98.6 87.5
- 21. UNIT CAPACITY FACTOR ( MDC NET) 100.0 98.8 86.1
- 22. UNIT CAPACITY FACTOR ( DER NET) 97.4 96.2 81.7
- 23. UNIT FORCED OUTAGE RATE 0.0 0.0 2.9
- 24. FORCED OUTAGE HOURS 0.0 0.0 5662.8 l
l.
l NRC MONTHLY REPORT PRINTED C/3/1999 Pag.3 6 DOCKET NO.60-306 UNIT PRAIRIE ISLAND NO,2 DATE 8/3/1999 COMPLETED BY DALE DUGSTAD PHONE 651-388-11214376 i
UNIT SHUTDOWNS AND POWER REDUCTIONS i
MONTH: JULY 1999 DATE UNIT TYPE HOURS REASON METHOD LER NUMBER SYSTEM COMPONENT l
7/31/1999 2
N/A 0
NOTES: None.
l l
l l
HER REASON METHOD SYSTEM CODE F-FORCED A-EQUIPMENT FAILURE 1-MANUAL DRAFT IEEE STD l
S-SCHEDULED B-MAINTENANCE OR TEST 2-MANUAL TRIP 1
C-REFUELING 3-AUTO TRIP D-REGULATORY RESTRICTION 4-CONTINUED E-OPERATOR TRAINING AND 5-REDUCED LOAD COMPONENT CODE l
LICENSE EXAMINATION l
9-OTHER IEEE STD 803A-1983 l
F-ADMINISTRATIVE G-OPERATIONAL ERROR H-OTHER l