Monthly Operating Repts for Dec 1997 for Prairie Island Nuclear Generating Plant,Unit 1 & 2
ML20198P154
Person / Time
Site: Prairie Island  
Issue date: 12/31/1997
From: Dugstad D, Sorensen J
NORTHERN STATES POWER CO.
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
NUDOCS 9801220020
Download: ML20198P154 (9)


Text

.

.t Northern States Power Coir.pany Prairie Island Nuclear Gener:1lng Pisnt 1717 Wakonada Dr. East Welch, tAnnesota 550e9 January 13,1998 Prairie island Technical Specifications Section 6.7.A.3 US Nuclear Regulatory Commission Atto: Docunent Control Desk Washington, DC 20555 PRAIRIE ISLAND NUCLEAR GENERATING PLANT Docket Nos. 50 282 License Nos. DPR 42 50-306 DPR60 Monthly Operating Report December 1997 Attached is the Monthly Operating Report for Decen1ber 1997 for the Priarle Island Nuclear Generating Plant.

Joel P Sorenson Plant Manager Prairie Island Nuclear Generating Plant c:

Regional Administrator Ill, NRC NRR Project Manager, NRC g

  1. b ' (f NRC Resident inspector State of Minnesota - Kris Sanda j

Attachment j.[v b lll lllll!ll!!!l!!llO!l[Illl 9901220020 971231 PDR ADOCK 05000282 R

PDR,

PRINTE0 01.M98 NRC MONTHLV REPORT P:gei DOCKET NO. 50-282 UNIT PRAIRIE ISLAND NO.1 DATE 01/o898 COMPLETED BY DALE DuGSTAD TELEPHONE 612 3881121-4376 NARBAI1YfJiUMMARY OF OEERATING EXPERIENCE MONIHLDECEMBER.1921 At the beginning of December, Unit 1 was still in the refueling (cycle 18 to 19) and maintenance outage that started on October 10. Some of the major tasks completed were: low pressure turbine rotor upgrade, steam generator insp0ction and repairs, reactor coolant pump motor inspection, charging pump discharge check valves replacement, internallifting rig work,10 Bani: transformer modification of tap changer, and refueling.

The reactor was taken critical on the 13th at 0100 and the generator was placed on-line on the 14th at 1355. The generator was taken off line on the 15th at 0423 to conduct tests on the new LP rotors (reactor was at hot standby). After the rotor tests were completed the generator was placed on-line on the 16th at 0114. The Unit obtained full power operation on the 19th at 0526.

Because of the LP rotor upgraue the Unit is producing additional megawatts. The values for the Designed Electrical Rating and Maximum Dependable Capacity (both gross and net) will be changed aftor the Unit completes an URGE test.

CURRENT CONTINUOUS OPERATING RUN OF 15 DAYS

NRC MONTHLY REPORT PRINTED 01/07/98 PageO DOCKET NO. 50 282 UNIT PRAIRIE ISLAND NO.1 DATE 0147/98 COMPLETED BY DALE DUGSTAD TELEPHONE 612-386-11214376 AVERAGE _ DAILY POWER LEVEL UNIT.1 MOfifH:.DECEMBEIL1911 DATE:

AYERAGE. DAILY POWER LEVEi.

12/01/97 0

12/02/97 0

12/03/97 1

12/04/97 3

12/05/97 3

12/06/97 6

12/07/97 14 12/08/97 10 12/09/97 16 12/10/97

-17 12/11/97 17 12/12/97 17 12/13/97 17 12/14/97 4

12/15/97 20 12/10/97 114 12/17/97 250 12/18/97 404 12/19/97 545 12/20/97 546 12/21/97 546 12/22/97 547 12/23/97 548 12/24/97 544 12/25/97 549 12/26/97 545 12/27/97 550 12/28/97 547 12/29/97 548 12/30/97 548 12/31/97 546 AVERAGE LOADS ADOVE 513 MWE NET ARE DUE TO COOLER CONDENSER CIRCULATING WATER

i NRC MONTHLY REPORT PRINTE0 01/Of/98 Page3 DOCKET NO. 50-282 UNIT PRAIRIE ISLAND NO.1 DATE O107/95 COMPLETED BY DALE DUGSTAD QPERATING DATA REPORT DEERAIINCLAIAIMS

1. UNIT NAME:

PRAIRIE ISLAND NO.1

2. REPORTING PERIOD; DECEMBER 1997
3. LICENSED THERMAL POWER (MWT): 1650
4. NAMEPLATE RATING (GROSS MWE): 593
5. DESIGN ELECTRICAL RATING (NET MWE): 530
6. MAXIMUM DEPF.NDABLE CAPACITY (GROSS MWE):

545

7. MAXIMUM DEPENDABLE CAPACITY (NET MWE):

513

8. IF CHANGES OCCUR IN CAPACITY RA.lNGS (ITEMS 3 7) SINCE LAST REPORT, GIVE REASON:

NONE

9. POWER LEVEL TO WHICH RESTRICTED,IF ANY (NET MWE): NONE
10. REASONS FOR RESTRICTIONS,IF ANY:

NONE flilS MQHIlj YR.TO-DATE CUMQLAI1YE

11. HOURS IN REPORTING PERIOD 744 8760 210768
12. NUMBER OF HOURS REACTOR CRITICAL 455.0 7030.3 180777.0
13. REACTOR RESERVE SHUTDOWN HOURS 0.0 0.00 5571.1
14. HOURS GENERATOR ON LINE 397.2 6906.8 178988.5
15. UNIT RESERVE SHUTDOWN HOURS 0.0 0.00 0.00
16. GROSS THERMAL ENERGY GENERATED (MWH) 575022 11224330 284277843
17. GROSS ELECTRICAL ENERGY GENERATED (MWH) 199760 3738100 93818710
18. NET ELECTRICAL ENERGY GENERATED (MWH) 185518 3522041 88234321
10. UNIT SERVICE FACTOR 53.4 79.5 84.9
20. UNIT AVAILADILITY FACTOR 53.4 79.5 84.9
21. UNIT CAPACITY FACTOR ( MDC NET) 48.6 78.4 82.9
22. UNIT CAPACITY FACTOR ( DER NET) 47 75.9 79
23. UNIT FORCED OUTAGE RATE O

4.8 4.6

24. FORCED OUTAGE HOURS 0.0 353.6 8540.7
25. SHUTDOWNS SCHEDULED OVE3 NEXT SIX MONTHS (WPE. DATE. AND DURATION OF EACH):

N/A

26. IF CURRENTLY SHUTDOWN ESTIMATED STARTUP DATE:

N/A

NRC MONTHLY REPORT PRINTED 01/07/98 Page 4 DOCKET NO. 50-282 UNIT PRAIRIE ISLAND NO.1 DATE 01/07/98 COMPLETED BY DALE DUGSTAD TELEPHONE 612 3881121-4376 UNIT SHUTDOWHSAND POWER REDUCTIONS MONTH; DECEMBEB_1MI DAT2 UNIT TYPE HOURS REASON METHOD LER NUMBER SYSTEM COMPONENT 12/01/97 i

S 346.8 C

4 N/A N/A N/A NOTES:

Continued refueling / maintenance out990 that started on Oct.18th.

IYEE REASQN MEIHOD RYRIENLCDDE F-FORCED A EQUIPMENT FAILURE 1-MANUAL DRAFT IEEE STD S-SCHEDULED D-MAINTENANCE OR TEST 2 MANUAL TRIP C-REFtJELING 3-AUTO TRIP D-REGULATORY RESTRCTION 440NTINUED E OPERATOR TRAINING AND 5-REDUCED LOAD COMP _QNENT CC DE LICENSE EXAMINATION 94THER IEEE STD 803A-1983 F ADMINISTRATIVE

- GOPERATIONAL ERROR H-OTHER

l NMC MONTHLY REPORT PRINTED 01/07/98 Page5 n

DOCKET NO. 50-306 UNIT PRAIRIE ISLAND NO. 2 DATE 01/07/96 COMPLETED BY DALE DUGSTAD TELEPHONE 612 386-11214376 NAMSMMMt.RY OF OPERATING EXPERIENCE MONTH: DECEMBER 1997.

1 Unit 2 was base loaded for the mothh of December. There were no shutdowns or power I

reductions, s

h L

1 K

E E

7; CURRENT CONTINUOUS OPERATING R'IN OF 94 DAYS 3-r

PRINTED 01/07/98 NRC MONTHLY REPORI l

Page 6 l

DOCKET NO 50-306 UNIT PRAIRIE ISLAND NO. 2 DATE 01/07/98 COMPLETED DY DALE DUGSTAD TELEPHONE 612 388-1121-4376 AVERAGE DAILY POWER LEVEL UNIT 2

?

MONTH: DECF.MBER.1992 DAIE; AVERAGE DAILY POWER LEVEL 12/01/97 529

/

12/02/97 530 12/03/97 529 12/04/97 534 12/05/97

$28 12/06/97 532 12/07/97 530 12/08/97 532 12/09/97 531 12/10/97 530 12/11/97 529 12/12/97 531 12/13/97 533 12/14/97 529 12/15/97 527 12/16/C7 530 12l17/97 525 12/18/97 530 12/19/97 530 12/20/97 531

-12/21/97 ti29 12/22/97 532 12/23/97 534 12/24/97 529 12/20/97 532 12/26/97 529 12/27/97 533 12/2E/97 531 12/29/97 531 12/30/97 532 12/31/97 533 AVERAGE LOADS ABOVE 512 MWE-NET ARE DUE TO COOLER CONDENSER CIRCULATING WATER

\\.'

l NRC MONTHLY REPORT PRINTED 01/07?98 Page 7 DOCKET NO. 50-306 UNIT PRAlRIE ISLAND NO. 2 DATE 01/07/98 COMPLETED BY DALE DUGSTAD TELEPHONE 612-388-1171-4376 OPERATING DATA REPORT QPERATING STATUS

1. UNIT NAME:

PRAIRIE ISLAND NO. 2

2. RtiPORTING PERIOD:

DECEMBER 1997

3. LICENSED THERMAL POWER (MWT): 1650
4. NAMEPLATE RATING (GROSS MWE):

533

5. DESIGN ELECTRICAL RATING (NE T MWE): 530
6. MAXIMUM DEPENDABLE CAPACITY (GROSS MWE):

544

7. MAXIMUM DEPENPABLE CAPACITY (NET MWE):

512

8. IF CHANGES OCCUR IN CAPACITY RATINGS (ITEMS 3 - 7) SINCE LAST REPORT, GIVE REASON:

NONE

9. POWER LEVEL TO WHICH RESTRICTED,IF ANY (NET MWII): NONE
10. REASONS FOR RESTRICTIONS,IF ANY:

NONE THIS MONTH YR.TO-DATE CUMULAINE

11. HOURS IN REPORTING PERIOD 744 8760 201886
12. NUMBER OF HOURS REACTOR CRITICAL 744.0 7233.0 178726.2
13. REACTOR RESERVE SHUTDOWN HOURS 0.0 0.00 1516.1
14. HOURS GENERATOR ON-LINE 744.0

).82.8 177227.1

15. UNIT RESERVE SHUTDOWN HOURP 0.0 0.00 0.00
16. GROSS THERMAL ENERGY GENERATED (MWH) 1224S21 11542478 282464587
17. GROSS ELECTRICAL ENERGY GENERATED (MWH) 414610 3862120 92497410
18. NET ELECTRICAL ENERGY GENERATED (MWH) 39469's 3640396 87451170
10. UNIT SERVICE FACTOR 100 82 87.8

- 20. UNIT AVAILABILITY FACTOR 100 82 87.8

21. UNIT CAPACITY rACTOR ( MDC NET)

"t,3.6 81.2 8e.3

22. UNIT CAPACITY FACTOR ( DER fiET) 100.1 78.4 81.7
23. UNIT FORCED OUTAGE RATE O

7.9 2.6

24. FORCC.D OUTAGE HOURS 0.0 617.2 4731.1
25. SHUTDOWNS CCHEDULED OVER NETT SIX MONTHS (TYPE. DATE. AND DURATION OF EACH):

N/A

26. IF CURRENTLY SHUTDOWN, ESTIMATED STARTUP DATE:

N/A l

l

i NRC MONTHLY REPORT PRINT ED 01/n7/98 L

Page8 DOCKET NO. 50-306 UNIT PRAIRIE ISLAND NO. 2 DATE 01/07/98 COMPLETED BY DALE DUGSTAD TELEPHONE 012-388-1121-4376 UNIT SHUTDOWNS AND POWER REDUCTIONS MONTH: DECEMBER 1997 DATE UNIT TYPE HOURS REASON METHOD LER NUMBER SYSTEM COMPONENT 12/31/97 2

None.

O NOTES:

IYEE REASON blETHOD SYSTEM CODE F FORCED A-EQUIPMENT FAILURE 1 MANUAL

- DRAFT IEEE STD S-SCHEDULED B-MAINTENANCE OR TEST 2-MANUAL TRIP C-REFUELING 3 AUTOTPIP D-REGULATORY RESTRICTION 4-CONTl;4UED E4PERATOR TRAINING AND 5-RdDUCED LOAD COMPONENT CODE LICENSE EXAMINATION 0-OTHER IEEE STD 803A-1983 F AOMINISTRATIVE W'ERATIONAL ERROR H-OTHER

_