l Northern States Power Cornpany l

1717 Wakonade Drive East l Welch, MN 55089 l Telephone 612-388-1121 1

! December 6,1996 Prairie Island Technical Specifications l Section 6.7.A.3 l I

US Nuclear Regulatory Commission Attn: Document Control Desk Washington, DC 20555 i

l i

PRAIRIE ISLAND NUCLEAR GENERATING PLANT l Docket Nos. 50-282 License Nos. DPR-42 50-306 DPR-60 l

Monthly Operating Report November 1996 Attached is the Monthly Operating Report for November 10')6 for the Prairie Island Nuclear Generating Plant.

i e manfada?O .

Michael D Wadley l Plant Manager Prairie Island Nuclear Generating Plant c: Regional Administrator-Ill, NRC NRR Project Manager, NRC h

l NRC Resident inspector y ,

State of Minnesota - Kris Sanda /

Attachment I

9612120170 961130 PDR ADDCK 05000282 R PDR

NRC' MONTHLY REPORT PRINTED 12/3/96

- Page 1 l ,

DOCKET NO. 50-282 I UNIT PRAIRIE ISLAND NO.1 DATE 12/3/96 COMPLETED BY DALE DUGSTAD  !

TELEPHONE 612-388-11214376 i

NARRATIVE

SUMMARY

OF OPERATING EXPERIENCE e

MONTH: NOVEMBER 1996 Unit 1 was base loaded for the month. There were no shutdowns or power reductions l

l 1

! I e

t CURRENT CONTINUOUS OPERATING RUN OF 151 DAYS

NRC MONTHLY REPORT PRINTED 12/3/96

. . Page 2 DOCKET NO. 50-282 UNIT PRAIRIE ISLAND NO.1 DATE 12/3/96 COMPLETED BY DALE DUGSTAD l TELEPHONE 612-386-1121-4376 l

AVERAGE DAILY POWER LEVEL '

UNIT 1 v

MONTH: NOVEMBER 1996 DATE: AVERAGE DAILY POWER LEVEL 11/1/96 526 11/2/96 529 11/3/96 528 11/4/96 529 11/5/96 526 11/6/96 530 11/7/96 528 11/8/96 529 11/9/96 529 11/10/96 528 11/11/96 528 11/12/96 529 11/1 %V 529 11/H M 526 11/15/96 528 11/16/96 528 11/17/96 525 11/18/96 531 11/19/96 528 11/20/96 529 11/21/96 529 11/22/96 526 )

11/23/96 528 l 11/24/96 529 l 11/25/96 528 i 11/26/96 527 11/27/96 528 '

11/28/96 527 11/29/96 527 11/30/96 529 l

l AVERAGE LOADS ABOV 513 MWE-NET ARE DUE TO COOLER CONDENSER CIRCULATING WATER

l NRC MONTHLY REPORT PRINTED 92/3/96 j

'. . Page 3 l

DOCKET NO. 50-282 i UNIT PRAIRIE ISt.AND NO.1 1 DATE 12/3/96 COMPLETED BY DALE DUGSTAD OPERATING DATA REPORT v

OPERATING STATUS

1. UNIT NAME: PRAIRIE ISt.AND NO.1
2. REPORTING PERIOD: NOVEMBER 1996 ,
3. LICENSED THERMAL POWER (MWT): 1650
4. NAMEPLATE RATING (GROSS MWE); 593
5. DESIGN ELECTRICAL RATING (NET MWE): 530
6. MAXIMUM DEPENDABLE CAPACITY (GROSS MWE); 545
7. MAXIMUM DEPENDABLE CAPACITY (NET MWE): 513
8. IF CHANGES OCCUR IN CAPACITY RATINGS (ITEMS 3 - 7) SINCE LAST REPORT, GIVE REASON: I NONE
9. POWER LEVEL TO WHICH RESTRICTED, IF ANY (NET MWE): NONE
10. REASONS FOR RESTRICTIONS, IF ANY: NONE THIS MONTH YR-TO-DATE CUMULATIVE  !
11. HOURS IN REPORTING PERIOD 720 8040 201264
12. NUMBER OF HOURS REACTOR CRITICAL 720.0 6637.4 172996.7 [
13. REACTOR RESERVE SHUTDOWN HOURS 0.0 0.00 5571.1
14. HOURS GENERATOR ON-LINE 720.0 6584.7 171277.7 l
15. UNIT RESERVE SHUTDOWN HOURS 0.0 0.00 0.00 1
16. GROSS THERMAL ENERGY GENERATED (MWH) 1184777 10675454 271828937
17. GROSS ELECTRICAL ENERGY GENERATED (MWH) 399550 3544280 89667990
18. NET ELECTRICAL ENERGY GENERATED (MWH) 380185 3345443 84319748
19. UNIT SERVICE FACTOR 100 81.9 85.1
20. UNIT AVAILABILITY FACTOR 100 81.9 85.1
21. UNIT CAPACITY FACTOR ( MDC NET) 102.9 81.1 83.1
22. UNIT CAPACITY FACTOR ( DER NET) 99.6 78.5 79 1
23. UNIT FORCED OUTAGE RATE O 0.9 4.6
24. FORCED OUTAGE HOURS 0.0 61.2 8187.1
25. SHUTDOWNS SCHEDULED OVER NEXT SIX MONTHS (TYPE. DATE, AND DURATION OF EACH):

N/A

26. IF CURRENTLY SHUTDOWN, ESTIMATED STARTUP DATE:

N/A

_ ~_- . _ - .

NRC MONTHLY REPORT PRINTED 12/3/96

, , Page 4 DOCKET NO. 50-282 l UNIT PRAIRIE ISLAND NO.1 l

DATE 12/3/96 COMPLETED BY DALE DUGSTAD TELEPHONE 612-388-1121-4376 1

UNIT SHUTDOWNS AND POWER REDUCTIONS v

i

! MONTH: NOVEMBER 1996 l

DATE UNIT TYPE HOURS ret. SON METHOD LER NUMBER SYSTEM COMPONENT r

11/1/96 1 None O NOTES:

l l

i l

IXEE REASON METHOD SYSTEM CODE F-FORCED A-EQUIPMENT FAILURE 1-MANUAL DRAFT IEEE STD S-SCHEDULED B-MAINTENANCE OR TEST 2-MANUAL TRIP C-REFUELING 3-AUTO TRIP D-REGULATORY RESTRICTION 4-CONTINUED E-OPERATOR TRAINING AND 5-REDUCED LOAD COMPONENT CODE LICENSE EXAMINATION 9-OTHER IEEE STD 803A-1983 F-ADMINISTRATIVE G-OPERATIONAL ERROR H-OTHER

NRC MONTHLY REPORT PRINTED 92/3/96

. PageG ,

l l

l DOCKET NO. 50-306 UNIT PRAIRIE ISLAND NO. 2 DATE 12/3/96 l COMPLETED BY DALE DUGSTAD  !

TELEPHONE 612-388-1121-4376 i i NARRATIVE

SUMMARY

OF OPERATING EXPERIENCE v

MONTH: NOVEMBER 1996

. Unit 2 was base loaded for the month. There were no shutdowns or power reductions.

l l

l l

I I

l l l

l I

1 l

1 l

4 CURRENT CONTINUOUS OPERATING RUN OF 151 DAYS a

i

NRC MONTHLY REPORT PRINTED 12/3/96

. , Page 6 DOCKET NO. 50-306 l UNIT PRAIRIE ISLAND NO. 2 DATE 12/3/96 COMPLETED BY DALE DUGSTAD TELEPHONE 612-388-11214376 1 1 l AyfRAGE DAILY POWER LEVEL UNIT 2 v

l MONTH: NOVEMBER 1996 DATE: AVERAGE DAILY POWER LEVEL 11/1/96 532 11/2/96 532 11/3/96 532 11/4/96 534 l 11/5/96 530 l 11/6/96 534 11/7/96 532

, 11/8/96 534 I 11/9/96 532 l

11/10/96 533 11/11/96 533 11/12/96 533 11/13/96 535 11/14/96 531 l 11/15/96 533 l 11/16/96 531 11/17/96 529 I 11/18/96 535 11/19/96 532 11/20/96 532 11/21/96 532 i i

11/22/96 535 j 11/23/96 528 11/24/96 533 11/25/96 532 11/26/96 532 11/27/96 533 11/28/96 531 11/29/96 531 11/30/96 531 i

4 1

AVERAGE LOADS ABOV 512 MWE-NET ARE DUE TC COOLER CONDENSER CIRCULATING WATER

NRO MONTHLY REPORT PRINTED 12/3/96 Page 7 DOCKET NO. 50-306 UNIT PRAIRIE ISLAND NO. 2 DATE 12/3/96 COMPLETED BY DALE DUGSTAD TELEPHONE 612-388-1121-4376 OPERATING DATA REPORT l

OPERATING STATUS

1. UNIT NAME: PRAIRIE ISLAND NO. 2
2. REPORTING PERIOD: NOVEMBER 1996
3. LICENSED THERMAL POWER (MWT): 1650
4. NAMEPLATE RATING (GROSS MWE): 593 j 5. DESIGN ELECTRICAL RATING (NET MWE): 530 4
6. MAXIMUM DEPENDABLE CAPACITY (GROSS MWE): 544 1
7. MAXIMUM DEPENDABLE CAPACITY (NET MWE): 512  !
8. IF CHANGES OCCUR IN CAPACITY RATINGS (ITEMS 3 - 7) SINCE LAS f REPORT, GIVE REASON: l

, NONE I l

9 POWER LEVEL TO WHICH RESTRICTED, IF ANY (NET MWE): NONE '

j 10. REASONS FOR RESTRICTIONS, IF ANY: NONE )

THIS MONTH YR-TO-DATE CdBlULATIVE

11. HOURS IN REPORTING PERIOD 720 8040 192382
12. NUMBER OF HOURS REACTOR CRITICAL 720.0 7940.2 170749.2
13. REACTOR RESERVE SHUTDOWN HOURS 0.0 0.00 1516.1
14. HOURS GENERATOR ON-LINE 720.0 7910.8 169300.3
15. UNIT RESERVE SHUTDOWN HOURS 0.0 0.00 0.00
16. GROSS THERMAL ENERGY GENERATED (MWH) 1185240 12905040 269698109
17. GROSS ELECTRICAL ENERGY GENERATED (MWH) 402280 4318950 88220260 l
18. NET ELECTRICAL ENERGY GENERATED (MWH) 383189 4089964 83415628 i
19. UNIT SERVICE FACTOR 100 98.4 88
20. UNIT AVAILABILITY FACTOR 100 98.4 88
21. UNIT CAPACITY FACTOR ( MDC NET) 103.9 99.4 86.4
22. UNIT CAPACITY FACTOR ( DER NET) 100.4 96 81.8
23. UNIT FORCED OUTAGE RATE O 1.6 2.4
24. FORCED OUTAGE HOURS 0.0 129.2 4113.9
25. SHUTDOWNS SCHEDULED OVER NEXT SIX MONTHS (TYPE, DATE, AND DURATION OF EACH):

REFUELING AND MAINT OUTAGE 1/1997. APPOX. DURATION 39 DAYS.

26. IF CURRENTLY SHUTDOWN, ESTIMATED STARTUP DATE:

4 N/A i

- - . . . . =- . .- .

NRC MONTHLY REPORT PRINTED 12/3/96

. ,,, Page 8 DOCKET NO. 50-306 i UNIT PRAIRIE ISLANC NO. 2 DATE 12/3/96 COMPLETED BY DALE DUGSTAD TELEPHONE 612-388-1121-4376 l

UNIT SHUTDOWNS AND POWER REDUCTIONS v

MONTH: NOVEMBER 1996 DATE UNIT TYPE HOURS REASON METHOD LER NUMBER SYSTEM COMPONENT 11/1/96 2 None O NOTES:

l l

I i

1 l

HEE ftEASON MEIliQQ SYSTEM CODE F-FORCED A-EQUIPMENT FAILbitE 1-MANUAL DRAFT lEEE STD S-SCHEDULED B-MAINTENANCE OR TEST 2-MANUAL TRIP C-REFUELING 3-AUTO TRIP D-REGULATORY RESTRICTION 4-CONTINUED E-OPERATOR TRAINING AND 5-REDUCED LOAD GQMEQS{E!G_GQDE LICENSE EXAMINATION 94THER lEEE STD 803A-1983 F-ADMINISTRATIVE G-OPERATIONAL ERROR H-OTHER