Text
Northern States Power Company Prairie Island Nuclear Generating Plant
)
1717 Wakonade Dr. East Welch, Minnesota 55089 1
)
May 5,1999 Technical Specifications 6.7.A.3
'l US Nuclear Regulatory Commission Attn: Document Control Desk Washington, DC 20555 PRAIRIE ISLAND NUCLEAR GENERATING PLANT Docket Nos. 50-282 License Nos. DPR-42 50-306 DPR-60 Monthly Operating Report April 1999 Attached is the Monthly Operating Report for April 1999 for the Prairie Island Nuclear Generating Plant.
- cel P. Sorensen Site General Manager Prairie Island Nuclear Generating Plant
/
c:
Regional Administrator-Ill, NRC NRR Project Manager, NRC NRC Resident inspector f
/{ g F State of Minnesota - Steve Minn Attachment 5
e y \\_ f u
9905140069 990430 PDR ADOCK 05000282 R
-)
PRINTED 5/4/1999.
NRC MONTHLY REPORT
.Page1
. DOCKET NO. 60 282 UNIT PRAIRIE ISLAND NO.1 DATE 5/4/1999 COMPLETED BY DALE DUGSTAD i
PHONE 651-388-1121-4376 NARRATIVE
SUMMARY
OF OPERATING EXPERIENCE MONTH: APRIL 1999 During the month of April, Unit 1 was base loaded. There was one power reduction and one shutdown for this month.
On the 16th of April, at 2205, a power reduction was started to begin the upcoming refueling outage. On the 17th, at 0011, the generator was taken off-line which began the 20th refueling cycle. The reactor was made sub-critical at 0019. The unit remained in the outage for the rest of the month.
The outage ended a continuous operation run of 84 days.
There are no other items to report.
l I
3 l
' CURRENT CONTINUOUS OPERATING RUN OF_0 DAYS
~
3,.
PRINTED 5/4/1999 NRC MONTHLY REPORT
- o Pp2 DOCKET NO. 50-282 UNIT PRAIRIE ISLAND NO.1 DATE 5/4/1999 COMPLETED BY DALE DUGSTAD PHONE 651-388-1121-4376 OPERATING DATA REPORT OPERATING STATUS
- 1. UNIT NAME:
PRAIRIEISLAND NO.1
- 2. REPORTING PERIOD:
APRIL 1999
- 3. LICENSED THERMAL POWER (MWT): 1650
- 4. NAMEPl. ATE RATING (GROSS MWE): 593
- 5. DESIGN ELECTRICAL RATING (NET MWE): 536
' O. MAXIMUM DEPENDABLE CAPACITY (GROSS MWE):
554
- 7. MAXIMUM DEPENDABLE CAPACITY (NET MWE):
522
' 8. IF CHANGES OCCUR IN CAPACITY RATINGS (ITEMS 3 - 7) SINCE LAST REPORT. GIVE REASON:
NONE
- 9. POWER LEVEL TO WHICH RESTRICTED, IF ANY (NET MWE): NONE
- 10. REASONS FOR RESTRICTIONS, IF ANY:
NONE THIS MONTH YR-TO-DATE CUMULATIVE
- 11. HOURS IN REPORTING PERIOD 720 2880 222408
- 12. NUMBER OF HOURS REACTOR CRITICAL 384.3 2401.6 191189.1
- 13. REACTOR RESERVE SHUTDOWN HOURS 0.0 0.00 5571.1
- 14. HOURS GENERATOR ON-LINE 384.2 2387.6 189326.3
- 15. UNIT RESERVE SHUTDOWN HOURS 0.0 0.00 0.00
- 16. GROSS THERMAL ENERGY GENERATED (MWH) 630540 3904263 301134618
{
- 17. GROSS ELECTRICAL ENERGY GENERATED (MWH) 210820 1353960 99623930
- 18. NET ELECTRICAL ENERGY GENERATED (MWH) 198056 1286534 93730016
- 19. UNIT SERVICE FACTOR 53.4 82.9 85.1
- 20. UNIT AVAILABILITY FACTOR 53.4 82.9 85.1
- 21. UNIT CAPACITY FACTOR ( MDC NET) 52.7. '
85.6 83.3
- 22. UNIT CAPACITY FACTOR ( DER NET) 51.3 83.3 79.5
)
- 23. UNIT FORCED OUTAGE RATE 0.0 6.2 4.8
- 24. FORCED OUTAGE HOURS 0.0 156.6 9483.8 1
4
PRINTED 5/4/1999 NRC MONTHLY REPORT Page 3 DOCKET NO. 50-282 UNIT PRAIRIE ISLAND NO.1 DATE 5/4/1999 COMPLETED BY DALE DUGSTAD PHONE 651-388-1121-4376 '
UNIT SHUTDOWNS AND POWER REDUCTIONS MONTH: APRIL 1999 DATE UNIT TYPE HOURS REASON METHOD LER NUMBER SYSTEM COMPONENT 4/16/1999 1
S 0
C 5
N/A N/A LN/A NOTES:
Start to ramp down in power for refuling outage.
4/17/1999 1
S 335.8 C
1 N/A.
N/A N/A NOTES:
Refueling outage, cycle 20.
i IYf.E REASON METHOD SYSTEM CODE F-FORCED A-EOUIPMENT FAILURE 1-MANUAL CRAFT IEEE STD S-SCHEDULED B-MAINTENANCE OR TEST 2-MANUAL TRIP C-REFUELING 3-AUTO TRIP i
D-REGULATORY RESTRICTION 4-CONTINUED E-OPERATOR TRAINING AND 5-REDUCED LOAD ' SQMPONENT CODE LICENSE EXAMINATION
{
9-OTHER lEEE STD 803A-1983 J
F-ADMINISTRATIVE G-OPERATIONAL ERROR H-OTHER '
o
PRINTED 5/N1999 '
NRC MONTHLY REPORT Page 4 -
DOCKET NO. 50-306 UNIT PRAIRIE ISLAND NO. 2 DATE 5/N1999 COMPLETED BY DALE DUGSTAD PHONE 651388-1121-4376
- NARRATIVE
SUMMARY
OF OPERATING EXPERIENCE -
MONTH: APRIL 1999 Durir.g the month of April, Unit 2 was base loaded. There were no shutdowns or power reductions for this month.
There are no other items to report.
1 I
i CURRENT CONTINUOUS OPERATING RUN OF 82 DAYS l
l g
i 4
PRINTED 5/4/1999 NRC MONTHLY REPORT Pa0e5 DOCKET NO. 60 308
' UNIT PRAIRIE ISLAND NO 2 DATE 5/4/1999 COMPLETED BY DALE DUGSTAD PHONE 651-388-11214376 OPERATING DATA REPORT OPERATING STATUS
- 1. UNIT NAME:
PRAIRIEISLAND NO.2
- 2. REPORTING PERIOD:
APRIL -
1999
- 3. LICENSED THERMAL POWER (MWT): 1650
- 4. NAMEPLATE RATING (GROSS MWE):
593
- 5. DESIGN ELECTRICAL RATING (NET MWE): 536
- 6. MAXIMUM DEPENDABLE CAPACITY (GROSS MWE):
554
- 7. MAXIMUM DEPENDABLE CAPACITY (NET MWE):
522
- 8. IF CHANGES OCCUR IN CAPACITY RATINGS (ITEMS 3 - 7) SINCE LAST REPORT, GIVE REASON:
NONE
- 9. POWER LEVEL TO WHICH RESTRICTED, IF ANY (NET MWE): NONE
- 10. REASONS FOR RESTRICTIONS,IF ANY:
NONE i
THIS MONTH YR TO-DATE CUMULATIVE l
- 11. HOURS IN REPORTING PERIOD 720 2880 213526 12, NUMBER OF HOURS REACTOR CRITICAL 720.0 2845.8 188167.9
- 13. REACTOR RESERVE SHUTDOWN HOURS 0.0 0.0 1516.1
- 14. HOURS GENERATOR ON-LINE 720.0 2810.9 186595.1
- 15. UNIT RESERVE SHUTDOWN HOURS 0.0 0.0 0.0
- 16. GROSS THERMAL ENERGY GENERATED (MWH) 1187166 4505744 297656825
- 17. GROSS ELECTRICAL ENERGY GENERATED (MWH) 401270 1549130 97585060
- 18. NET ELECTRICAL ENERGY GENERATED (MWH) 379816 1470044 92256373 i
- 19. UNIT SERVICE FACTOR 100.0 97.6 87.4
)
- 20. UNIT AVAllABILITY FACTOR 100.0 97.6 87.4
- 21. UNIT CAPACITY FACTOR ( MDC NET) 101.1 97.8 85.9
- 22. UNIT CAPACITY FACTOR ( DER NET) 98.4 95.2 81.5
- 23. UNIT FORCED OUTAGE RATE 0.0 0.0 2.9
- 24. FORCED OUTAGE HOURS 0.0 0.0 5662.8 9
I l
4 PRINTED 5/4/1999 -
NRC MONTHLY REPORT Page 6 DOCKET NO. 50-306 UNIT PRAIRIE ISLAND NO. 2 DATE 5/4/1999 COMPLETED BY DALE DUGSTAD PHONE 651388-1121-4376 UNIT SHUTDOWNS AND POWER REDUCTIONS MONTH: APRIL 1999 DATE UNIT TYPE HOURS REASON METHOD LER NUMBER SYSTEM COMPONENT 4/30/1999 2
N/A 0
NOTES: None.
1 1
i 1
l HP1 REASON METHOD SYSTEM CODE F-FORCED A-EQUIPMENT FAILURE 1-MANUAL DRAFT IEEE STD S-SCHEDULED B-MAINTENANCE OR TEST '
2-MANUAL TRIP C-REFUELING 3-AUTO TRIP D-REGULATORY RESTRICTION 4-CONTINUED E-OPERATOR TRAINING AND 5-REDUCED LOAD COMPONENT CODE LICENSE EXAMINATION i
9-OTHER lEEE STD 803A-1983
]
F-ADMINISTRATIVE
]
G4PERATIONAL ERROR i
H-OTHER z
.,..,