ML20137T289

From kanterella
Jump to navigation Jump to search
Monthly Operating Repts for March 1997 for Prairie Island Nuclear Plant
ML20137T289
Person / Time
Site: Prairie Island  Xcel Energy icon.png
Issue date: 03/31/1997
From: Dugstad D, Sorensen J
NORTHERN STATES POWER CO.
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
NUDOCS 9704160059
Download: ML20137T289 (9)


Text

Northern States Power Company 1717 Wakonada Drive East Welch, MN 55089 Telephone 612-388-1121 April 8,1997 Prairie Island Technical Specifications Section 6.7.A.3 US Nuclear Regulatory Commission Attn: Docume.it Control Desk Washington '.)C 20555 l

PRAIRIE ISLAND NUCLEAR GENERATING PLANT l Docket Nos. 50-282 License Nos. DPR-42  !

50-306 DPR-60 Monthly Operating Report  !

March 1997  ;

1 l

Attached is the Monthly Operating Report for March 1997 for the Prairie island Nuclear Generating Plant.

Joel P Sorensen Plant Manager /

Prairie Island Nuclear Generating Plant ,l[

c: Regional Administrator-Ill, NRC l I NRR Project Manager, NRC NRC Resident inspector State of Minnesota - Kris Sanda Attachment 9704160059 970331

PDR ADOCK 05000292 R pga ;

lilJ.l$1ll@@)II!!IllN

PRINTED 04/03/97 NRC MONTHLY REPORT Page 1

+ DOCKET NO. 50-282 UNIT PRAIRIE ISLAND NO.1 -

DATE 04/03/97 COMPLETED BY DALE DUGSTAD TELEPHONE 612-388-1121-4376 NARRATIVE

SUMMARY

OF OPERATING EXPERIENCE MONTH: MARCH 1997 Unit 1 was base loaded for the month. There were no shutdowns or power reductions CURRENT CONTINUOUS OPERATING RUN OF 272 DAYS

9 PRINTED O4/03/97 ;

NR.C MONTHLY REPORT Page 2 DOCKET NO. 50-282 UNIT PRA!RIE ISLAND NO.1 DATE 04/03/97 COMPLETED BY DALE DUGSTAD TELEPHONE 612-388-1121-4376

. AVERAGE DAILY POWER LEVEL l UNIT 1 MONTH: MARCH 1997 DATE: AVERAGE DAILY POWER LEVEL 03/01/97 531 03/02/97 531 03/03/97 524 03/04/97 528 03/05/97 528 03/06/97 528 03/07/97 527 03/08/97 530 03/09/97 529 a

03/10/97 528 03/11/97 529 03/12/97 530 03/13/97 527 03/14/97 529 03/15/97 529 03/16/97 529 03/17/97 528 03/18/97 526 03/19/97 531 03/20/97 528 03/21/97 531 03/22/97 526 03/23/97 525 03/24/97 528 ,

1 03/25/97 525 03/26/97 525 l 03/27/97 528 03/28/97 524 03/29/97 527 03/30/97 523 ,

  • 03/31/97 523 l 1

AVERAGE LOADS ABOVE 513 MWE NET ARE DUE TO COOLER CONDENSER CIRCULATING WATER 1

l

PRINTED 04/03/97 NRC MONTHLY REPORT Page 3 DOCKET NO. 50-282 - 'J UNIT PRAIRIE ISLAND NO.1 DATE 04/03/97

, I COMPLETED BY DALE DUGSTAD OPERATING DATA REPORT

]

OPERATING STATUS

1. UNIT NAME: PRAIRIE ISLAND NO.1
2. REPORTING PERIOD: MARCH 1997
3. LICENSED THERMAL POWER (MWT): 1650

. 4. NAMEPLATE RATING (GROSS MWE): 593

, 5. DESIGN ELECTRICAL RATING (NET MWE): 530 ,

i 6. MAXIMUM DEPENDABLE CAPACITY (GROSS MWE): 545

> 7. MAXIMUM DEPENDABLE CAPACITY (NET MWE): 513 l

8. IF CHANGES OCCUR IN CAPACITY RATINGS (ITEMS 3 - 7) SINCE LAST REPORT, GIVE REASON:

NONE

9. POWER LEVEL TO WHICH RESTRICTED, IF ANY (NET MWE): NONE
10. REASONS FOR RESTRICTIONS, IF ANY: NONE i

THIS MONTH YR TO-DATE CUMULATIVE

11. HOURS IN REPORTING PERIOD 744 2160 204168
12. NUMBER OF HOURS REACTOR CRITICAL 744.0 2160.0 175900.7
13. REACTOR RESERVE SHUTDOWN HOURS 0.0 0.00 5571.1
14. HOURS GENERATOR ON-LINE 744.0 2160.0 174181.7
15. UNIT RESERVE SH9TDOWN HOURS 0.0 0.00 0.00
16. GROSS THERMAL ENcRGY GENERATED (MWH) 1224576 3549229 276602742
17. GROSS ELECTRICAL ENERGY GENERATED (MWH) 412760 1196720 91277330
18. NET ELECTRICAL ENERGY GENERATED (MWH) 392465 1137897 85850177
19. UNIT SERVICE FACTOR 100 100 85.3
20. UNIT AVAILABillTY FACTOR 100 100 85.3
21. UNIT CAPACITY FACTOR ( MDC NET) 102.8 102.7 83.3
22. UNIT CAPACITY FACTOR ( DER NET) 99.5 99.4 79.3
23. UNIT FORCED OUTAGE RATE O O 4.5
24. FORCED OUTAGE HOURS 0.0 0.0 8187.1
25. SHUTDOWNS SCHEDULED OVER NEXT SIX MONTHS (TYPE, DATE, AND DURATION OF EACH):

Refueling outage scheduled for October 15,1997, approx. 50 days.

26. IF CURRENTLY SHUTDOWN, ESTIMATED STARTUP DATE:

N/A o

\

PRINTED 04/03/97 NRC MONTHLY REPORT Page 4 l

, e i DOCKET NO. 50-282 l UNIT PRAIRIE ISLAND NO.1 DATE 04/03/97 COMPLETED BY DALE DUGSTAD ,

TELEPHONE 612-388-1121-4376 l i

i 1

UNIT SHUTDOWNS AND POWER REDUCTIONS MONTH: MARCH 1997 DATE UNIT TYPE HOURS REASON METHOD LER NUMBER SYSTEM COMPONENT 03/31/97 1 None 0 NOTES: No shutdowns or power reduction for March.

TYPE REASON METHOD SYSTEM CODE F-FORCED A EQUIPMENT FAILURE 141ANUAL DRAFT IEEE STD S SCHEDULED B-MAINTENANCE OR TEST 2-MANUAL TRIP C-REFUELING 3-AUTO TRIP j D-REGULATORY RESTRICTION 4-CONTINUED l E-OPERATOR TRAINING AND 5-REDUCED LOAD COMPONENT CODE UCENSE EXAMINATION 94THER IEEE STD 803A-1983 G-OPERATIONAL ERROR H-OTHER .

4 4

PRINTED 04/03/97

- NRC MONTHLY REPORT Page0

, . i DOCKET NO. 50-306 J UNIT PRAIRIE ISLAND NO. 2 DATE 04/03/97 COMPLETED BY DALE DUGSTAD TELEPHONE 612 38811214376 NARRATIVE

SUMMARY

OF OPERATING EXPERIENCE

- MONTH: MARCH 1997 For March, Unit 2 continued with the refueling outage that started on Jan. 25th. The outage was extended due to two items:

1. An unreviewed safety question conceming the cooling water emergency intake line.
2. Two issues conceming Aux Feedwater:

I LA. Aux Feedwater operability with regards to a loss of FW ATWS event.

B. Aux Feedwater Pump runout protection (LER 1-96-010).

The outage ended on Sunday March 30 @ 0005 when the generator went on-line. The unit is ,

limited to less than 40% of reactor power due to the AFW/FW ATWS issue.

Spent Fuel Pool Update:

Fuel assemblies in each core - 121 -

Fuel assemblies in the spent fuel pool consolidate - 18 unconsolidated 1157 Licensed spent fuel pool storage capacity - 1386 Fuel assemblies in Dry Cask Storage - 280 B

a i

3 4

d5 e

4 4 .

l ' CURRENT CONTINUOUS OPERATING RUN OF 1 DAYS

PRINTED 04/03/97

- 'NRC MONTHLY REPORT

  • Page 6 e.

DOCKET NO. 50-306 UNIT PRAlRIE ISLAND NO. 2 DATE 04/03/97 COMPLETED BY DALE DUGSTAD TELEPHONE 612 388-1121-4376 A_yERAGE DAILY POWEILLEVEL UNIT 2 MONTH: MARCH 1997 4

DATE: AVERAGE DAILY POWER LEVEL 03/01/97 2 03/02/97 -2 03/03/97 -2 03/04/97 -2 03/05/97 -2 I 03/06/97 2 03/07/97 -3 03/08/97 -3 03/09/97 -3 03/10/97 2 03/11/97 2 03/12/97 -2 03/13/97 -2 03/14/97 -8 03/15/97 -15 03/16/97 15 03!17/97 -16 03/18/97 -17 03/19/97 -17

! 03/20/97 -17 i 03/21/97 -17 03/22/97 -18 03/23/97 -18 03/24/97 -17 03/25/97 16 03/26/97 -16 03/27/97 -17 03/28/97 -18 03/29/97 -19 03/30/97 101 03/31/97 146 2

e AVERAGE LOADS ABOVE 512 MWE NET ARE DUE TO COOLER CONDENSER CIRCULATING WATER

4 PRINTED 04/03/97 o- NRC MONTHLY REPORT Page 7 o

DOCKET NO. 50-306 UNIT PRAIRIE ISLAND NO. 2 DATE 04/03/97 COMPLETED BY DALE DUGSTAD TELEPHONE 612-38811214375 ,

OPERATING DATA REPORI OPERATING STATUS

1. UNIT NAME: PRAIRIE ISLAND NO.2
2. REPORTING PERIOD: MARCH 1997
3. LICENSED THERMAL POWER (MWT): 1650
4. NAMEPLATE RATING (GROSS MWEt 593

,5. DESIGN ELECTRICAL RATING (NET MWti). 530

6. MAXIMUM DEPENDABLE CAPACITY (GROSS MWE): 544
7. MAXIMUM DEPENDABLE CAPACITY (NET MWE): 512
8. IF CHANGES OCCUR IN CAPACITY RATINGS (ITEMS 3 7) SINCE LAST REPORT, GIVE REASON:

NONE

9. POWER LEVEL TO WHICH RESTRICTED, IF ANY (NET MWE): Less than 40% reactor power.
10. REASONS FOR RESTRICTIONS,IF ANY: Due to AFW with loss of FW ATWS issue.

THIS MONTH YR TO-DATE CUMUt).7tVE

11. HOURS IN REPORTING PERIOD 744 2160 195280
12. NUMBER OF HOURS REACTOR CRITICAL 86.3 664.2 172157.4
13. REACTOR RESERVE SHUTDOWN HOURS 0.0 0.00 1516.1
14. HOURS GENERATOR ON-LINE 47.9 622.8 170667.1
15. UNIT RESERVE SHUTDOWN HOURS 0.0 0.00 0.00
16. GROSS THERMAL ENERGY GENERATED (MWH) 23355 925035 271847144
17. GROSS ELECTRICAL ENERGY GENERATED (MWH) 7000 308560 88943850
18. NET ELECTRICAL ENERGY GENERATED (MWH) -1047 282991 84093765
19. UNIT SERVICE FACTOR 6.4 28.8 87.4
20. UNIT AVAILABILITY FACTOR 6.4 28.8 87.4
21. UNIT CAPACITY FACTOR ( MDC NET) -0.3 25.6 85.8
22. UNIT CAPACITY FACTOR ( DER NET) 0.3 24.7 81.2
23. UNIT FORCED OUTAGE RATE 92.3 48.1 2.7
24. FORCED OUTAGE HOURS 577.2 577.2 469).1
25. SHUTDOWNS SCHEDULED OVER NEXT SIX MONTHS (TYPE, DATE, AND DURATION OF EACH):

N/A

26. IF CURRENTLY SHUTDOWN, ESTIMATED STARTUP DATE:

N/A

~ - , , - , ,

-W PRINTED 04/03/97 NRC MONTHLY REPORT Page 8

, , DOCKET NO. 50-306 UNIT PRAIRIE ISLAND NO.2 DATE 04/03/97 COMPLETED BY DALE DUGSTAD TELEPHONE 612-388-1121-4376 UNIT SHUTDOWNS AND POWER REDUCTIONS i

i MONTH: MARCH 1997 i

DATE UNIT TYPE HOURS REASON METHOD LER NUMBER SYSTEM COMPONENT

. 03/01/97 2 S 118.9 C 4 N/A NOTES: Continued cycle 18 refueling outage.

03/05/97 2 F 504 D 4 i NOTES: Ouiage extended due to cooling water emergency intake line issue.

03/26/97 2 F 73.2 D 4 1-97-00

NOTES
Outage extended due to AFW operability with regards to a loss of FW ATWS event.

03/30/97 2 F 0 D 5 1-97-00 NOTES: Umited to less than 40% reactor power due to AFW / FW ATWS issue.

HP1 REASON METHOD SYSTEM CODE F-FORCED A-EQUIPMENT FAILURE 1-MANUAL DRAFT lEEE STD S-SCHEDULED B-MAINTENANCE OR TEST 2-MANUAL TRIP C-REFUELING 3-AUTO TRIP D-REGULATORY RESTRICTION 4-CONTINUED E-OPERATOR TRAINING AND 5-REDUCED LOAD COMPONENT CODE UCENSE EXAMINATION 9-OTHER IEEE STD 803A-1983 F-ADMINISTRATIVE G-OPERATIONAL ERROR H-OTHER