ML20100C116

From kanterella
Jump to navigation Jump to search
Deficiency Rept Re Pressurizer PORVs Preoperational Test Discrepancies.Special Operations Procedure Will Be Performed to Resolve Existing Test Discrepancies
ML20100C116
Person / Time
Site: Wolf Creek 
Issue date: 11/19/1984
From: Koester G
KANSAS GAS & ELECTRIC CO.
To: Denise R
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
References
KMLNRC-84-199, NUDOCS 8412050302
Download: ML20100C116 (2)


Text

g KANSAS GAS AND ELECTRIC COMPANY TPE ELECTRC COMPANY CLENN L ICOESTER vect passegmr.sevctran um._%,- to inna Mr. R.P. Denise, Director Wolf Creek Task Force NOV 2 31984 U.S. Nuclear Regulatory Commission Region IV y

611 Ryan Plaza Drive, Suite 1000 Arlington, Texas 76011 KMLNRC 84-199 Re:

Docket No. STN 50-482 Reft Final 10CFR50.55(e) Report KMLNRC 84-196 dated 11/13/84 from GLKoester, KG&E, to RPDenise, NRC Subj: Resolution of Pressurizer PORV Test Discrepancies

Dear Mr. Denise:

The purpose of this letter is to provide, as was indicated in the Reference, Kansas Gas and Electric Company's plans for resolution of the pressurizer power operated relief valves (PORVs) preoperational test discrepancies.

The failure of the pressurizer PORVs to close as required during performance of a portion of their preoperational test is an outstanding test discrepancy. The pressurizer preoperational test (SU3-BB13) will be closed with outstanding test discrepancies which will be resolved after fuel load but prior to initial criticality through the use of an Operations Special Procedure written for testing of the PORVs.

After fuel load the valve surveillance required by the Wolf Creek Generating Station (WCGS) Technical Specifications will be performed.

Upon successful completion of this surveillance test, the plant will j

be brought to the appropriate temperature and pressure, at which time the Special Procedure for testing can be completed. This special Procedure will entall all steps of the preoperational test necessary to resolve the existihg test discrepancies. This will include a test i

of the automatic actuation function and the extended blowdown function

)

of these valves.

%2h 0

4 e

cc m 201 N. Market ~ WicNta, Kansas - Man Address: PO. Box 208 I Wichita, Kansas 67201 - Telephone: Area Code (316) 261-6451

~

...r, __

~..

F J

I I

r.

fMr. Denise i

KMLNRC 84-199

' 2-November 19, 1984-Technical-justification for this course of' action was provided in the Reference and copies of the Special Procedure for testing the.:

~

PORVs will be made available for.your review..

If you have any questions concerning this subject, please contact me or Mr. Otto Maynard of my staff.

Yours very truly,

<)

Glenn L. Koester Vice President. Nuclear GLKabb xc: RCDeYoung PO'Connor (2)

HBundy

-