ML20101N048

From kanterella
Jump to navigation Jump to search
Final Deficiency Rept Re RCS Resistance Temp Detector Calibr Data.Initially Reported on 840801.Manufacturer Calibr Procedures Revised to Allow Recalibr at Facility.All Resistance Temp Detectors Will Be Replaced or Refurbished
ML20101N048
Person / Time
Site: Wolf Creek Wolf Creek Nuclear Operating Corporation icon.png
Issue date: 12/07/1984
From: Koester G
KANSAS GAS & ELECTRIC CO.
To: Denise R
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
References
KLMNRC-84-216, NUDOCS 8501030332
Download: ML20101N048 (1)


Text

1 KANSAS GAS AND ELECTRIC COMPANY THE ELECTAC COMPANY OLENN L MOESTER wcs possance? . Muctram December 7, 1984 Mr. R.P. Denise, Director c g Wolf Creek Task Force U.S. Nuclear Regulatory Commission Region IV Cf[

611 Ryan Plaza Drive, Suite 1000 e.

Arlington, Texas 76011  ;{

KMLNRC 84-216 Re Docket No. STN 50-482 **4 Ref: Interim Report KMLNRC 84-158 dated 8/31/84 from GLKoester, KG&E, to EHJohnson, NRC Subj: Final 10CFR50.55(e) Report - Reactor Coolant System Resistance Temperature Detector Calibration Data (53564-K148)

Dear Mr. Denise:

This letter provides the final report submitted pursuant to 10CFR50.55(e) concerning Reactor Coolant System Resistance Temperature Detectors (RTD)

Calibration Data at Wolf Creek Generating Station (WCGS) . This matter was initially reported on August 1, 1984 with supplemental information provided in the Reference.

Investigation of the calibration discrepancies described in the Reference has resulted in a revision to the RTD manufacturer's (RdF) calibration procedures. This would allow for recalibration of the RTDs at RdF's facility. However, due to some unrelated physical damage to the WCGS RTDs, all RCS RTDs are being replaced or refurbished. These units will be calibrated per the revised RdF calibration procedure. The aforementioned corrective actions will be completed prior to fuel load.

If you have any questions concerning this matter, please contact me or Mr. Otto Maynard of my staff.

Yours very truly,

{dfh GLK bb xc:RCDeYoung PO'Connor (2)

HBundy 0501030332 041207 PDR ADOCK 05000402 S PDR M-201 N. Market -WicNta, Kansas - Man Address: PO. Box 208 I W1cNta, Kansas 67201 - Telephone: Area Code (316) 261-6451 k

\