 Issue dateTitleTopic
ML20112G3874 June 1996Potential Part 21 Rept Re Capscrews W/Trace Code of K7 Mfg by Cardinal Industries (Now Known as Accutech) & Distributed by Energy & Process Corp for Plant CP S/N 0194012.Pump/motor Would Remain Operational Throughout Worse Case Scenario
ML20126J59631 December 1992Part 21 Rept Re Potential Loss of RHR Cooling During Nozzle Dam Removal.Nozzle Dams May Create Trapped Air Column Behind Cold Leg Nozzle Dam.Mod to Nozzle Dams Currently Underway. Ltrs to Affected Utils EnclHydrostatic
ML20125C7167 December 1992Part 21 Rept Re Possibility for Malfunction of Declutching Mechanisms in SMB/SB-000 & SMB/SB/SBD-00 Actuators. Malfunction Only Occurs During Seismic Event.Balanced Levers May Be Purchased from Vendor.List of Affected Utils EnclStroke time
Anchor Darling
ML20086G29321 November 1991Part 21 Rept Re Failure of Model 763 & 763A Static Pressure Transmitters.Caused by Short Circuit in Connector Pin to Adjacent Mounting Screw.Engineering Drawings & Mfg Work Instructions Changed & Stock Purged of Subj Transmitters
ML20059N51916 October 1990Part 21 Rept Re Rod & Bearing Assembly Failures Noted by Wolf Creek Nuclear Operating Corp During Testing.Rept Will Be Issued Outlining Root Cause & Corrective Actions to Prevent Recurrence
ML17223A74526 January 1990Part 21 Rept Re Backup Rings Furnished in Spare Parts Seal Kits & in 25 Gpm 4 Way Valves as Part of Actuators Made of Incorrect Matl.Rings Should Be Viton & Have Been Identified as Buna N
ML20246J06329 August 1989Part 21 Rept Re Namco Refusal to Certify Design & Matls for Replacement Namco Limit Switches Supplied by Masoneilan. Initially Reported on 890825.Switches Put on QC Hold Until Final Disposition of Switches Determined
ML20244D2901 June 1989Part 21 Rept Re Buchanan 724 Terminal Blocks Supplied by Limitorque Corp,Rather than Correct Buchanan 524 Terminal Blocks.Caused by Error in Order Processing.Training Held to Ensure That Procedures Followed Correctly
ML20235Y4813 March 1989Part 21 Rept Re Cracked Welds Discovered on Striker Plates of GE Circuit Breakers.Initially Reported on 890130.GE Advised Util That Striker Plates Subj to Impact Loading Only When Breaker in Racked Out & Operated in Test Position
ML20195F61918 November 1988Part 21 Rept Re GE Magne-Blast Circuit Breakers.Initially Reported on 881116.Welds on All safety-related Breakers Will Be Repaired Prior to Entry Into Hot ShutdownOvertravel
ML20151W78416 August 1988Part 21 Rept Re Cracking of Slides Used in Four Way Valves Furnished on Actuators for MSIVs Due to Brazing/Heat Treating of Slide Matl.All Sites Using Actuators Will Be Formally Notified by 880826.List Encl
ML20151B4291 April 1988Part 21 Rept Re Inconsistencies in Gould,Inc Certificate of Compliance Received W/Class 1E Fuses Procured from Planned Maint Sys Due to Fuses Not Being Qualified for Certain Specs.Initially Reported on 880329.Fuses Remain on Hold
ML20234C73523 June 1987Supplemental Part 21 Rept Re Silicone Foam Seal Anomolies at Wolf Creek Generating StationFire Watch
ML20211P72123 February 1987Part 21 Rept Re Rockbestos Coaxial Cable Used in Sorrento Electronics Digital & Analog high-range Radiation Monitor. Insulation Resistance at High Temp Not High Enough for Ion Chamber & Associated Electronics to Operate Properly
ML20153D88617 February 1986Part 21 Rept Re Failure of Penetration & Conduit Seal Configurations During Fire Tests.Initially Reported on 860214.Evaluation of Number & Location of Defective Seals in Progress.Nrc Assistance RequestedFire Barrier
ML20137W26130 September 1985Update to Part 21 Rept Re Insp for Cracked Welds Discovered in Generator Brackets.Insp for Callaway Unit 1 Postponed Until Next Refueling Outage (Probably Apr 1986).No Cracks Discovered During Insp at Wolf Creek
ML20135E1165 September 1985Part 21 Rept Re Use of Connectron non-IEEE Qualified Matl in Spare Part Terminal Blocks Supplied to Facilities. Appropriate Customers Notified.Terminal Blocks Should Be Reviewed to Identify Defective Matl
ML20210G99213 August 1985Part 21 Rept Re Failure of Isolated Worm Shaft Gear When Certain Critical Speeds Combined W/Repetitive Transfer of Actuator Clutch Mechanism from Manual (Handwheel) to Motor Drive Mode.Two Possible Solutions Noted
ML20117B8141 May 1985Part 21 Rept Re Ruskin Fire Dampers Installed at Facility. Initially Reported on 850426.Fire Dampers Found in Discrepant Condition Will Be Reworked in Order to Assure Integrity & Proper Functioning
ML20116E84823 April 1985Part 21 Rept Forwarding Rev 1 to Insp Procedure for Investigating Emergency Diesel Generators for Fractured Welds on Air Deflectors.Rev Will Be Forwarded to Each Facility
ML20116D32022 April 1985Part 21 Rept Re Ruskin Mfg Co Welds Used to Join Damper to Damper & Damper Section to Mullion Plates.Welds Not in Accordance W/Approved Design Drawings.Drawing 5415 Revised to Indicate Weld Spacing.Drawing of Weld Spacing Encl
ML20115J13615 April 1985Forwards Insp Procedure for Investigating Emergency Diesel Generators for Fractured or Cracked Welds to Determine If Part 21 Problem Exists,Per Jg Borman
ML20100E06529 March 1985Part 21 Rept Re Series of Cracked Welds Discovered in Generators.Welds Occurred in Conical Baffle Section of Coil Guards.All Units Will Be Inspected.Affected Plants Listed
NRC-85-3024, Part 21 Rept Re Possible Undetectable Failures in ESF Actuation Sys.Initially Reported on 791107.Possibility of Undetectable Failures Remain Under Certain Circumstances Despite Change in Hardware22 March 1985Part 21 Rept Re Possible Undetectable Failures in ESF Actuation Sys.Initially Reported on 791107.Possibility of Undetectable Failures Remain Under Certain Circumstances Despite Change in Hardware
ML20102B95313 February 1985Supplemental Final Deficiency Rept (53564-K159) Re Concrete Coatings Inside Containment.Initially Reported on 841213. Coated Concrete Surfaces Inside Containment Will Perform Satisfactorily Under DBA ConditionsCoatings
ML20107B6937 February 1985Final Deficiency Rept (53564-K161) Re Uncertainties in Resistance Temp Detectors Calibr.Westinghouse Evaluation Demonstrated That Revised Resistance Temp Detectors Uncertainty Acceptable
ML20101T12125 January 1985Final Deficiency Rept (53564-K159) Re Concrete Coatings Inside Containment.Initially Reported on 841213.Destructive Adhesion Tests Performed on Locations Selected by Sampling Plan to Verify Acceptability of CoatingsCoatings
ML20104B14718 January 1985Final Deficiency Rept Re Insp of Structural Steel Welds. Initially Reported on 840918.Structural Concerns Identified & Corrective Action Repts Issued to Have Shims Less than 1/4 Inch Thick Placed Flush W/Mounting Frame
ML20104A86713 January 1985Final Deficiency Rept Re Standby Diesel Generator B Left Bank Turbocharger.Initially Reported on 840504.Caused by Loose Lock Nut on Left Bank Turbocharger Lubricating Oil Pump Centrifuge.Damaged Turbocharger Repaired & Inspected
ML20104A81713 January 1985Final Deficiency Rept Re Subcooling Core Monitor Alarm & Caution Relays.Initially Reported on 840821.Interposing Relays & Diodes Added to Sys to Minimize Potential for & Suppress Effects of Any Arcs Generated
ML20114C91413 January 1985Final Deficiency Rept (53546-K158) Re ASME Hangers & Component Supports.Initially Reported on 841212.Insulation Contractors Revised Procedures & Retrained Personnel to Preclude Further Tampering of Supports
ML20104B92413 January 1985Final Deficiency Rept Re Water Damaged Limitorque Motor Operators.Initially Reported on 840203.Caused by Leakage During Sys Flushing & Hydrostatic Testing Activities.Seals Added Inside Conduit & T-drains Installed in OperatorHydrostatic
ML20114D10813 January 1985Final Deficiency Rept (53564-K118) Re safety-related Field Procurement by Constructor.Initially Reported on 840103. Complete Review of Constructor safety-related Purchase Orders Completed.All Nonconformance Repts Resolved
ML20114C84413 January 1985Final Deficiency Rept Re Microbiologically Induced Corrosion in Hxs.Initially Reported on 840601.All HXs Utilizing Lake Water for Cooling Medium Eddy Current Inspected for Microbiologically Induced CorrosionHydrostatic
ML20114C79813 January 1985Final Deficiency Rept Re Removal & Replacement of ASME Components in Support of Cleaning & Flushing Activities. Initially Reported on 840711.Investigation Into Handling & Storage of ASME Components Removed from Sys Conducted
ML20112D8064 January 1985Final Deficiency Rept Re MSIV Lockwashers.Initially Reported on 841207.Lockwashers Installed Via Startup Field Rept I-SU-122 & Will Be Completed Prior to Fuel Load
ML20112F5423 January 1985Forwards Dec 1984 Status Rept Re 10CFR50.55(e)/Part 21 Open Items
RBG-19-803, Final Deficiency Rept DR-234 Re Short Cap Screws,Shallow Bolt Holes,Damaged Dowel Pins & Damaged or Missing Lock Devices for Hanger Block Bolts in Check Valves Supplied by Velan Engineering,Ltd.Initially Reported on 84112828 December 1984Final Deficiency Rept DR-234 Re Short Cap Screws,Shallow Bolt Holes,Damaged Dowel Pins & Damaged or Missing Lock Devices for Hanger Block Bolts in Check Valves Supplied by Velan Engineering,Ltd.Initially Reported on 841128
ML20101N0487 December 1984Final Deficiency Rept Re RCS Resistance Temp Detector Calibr Data.Initially Reported on 840801.Manufacturer Calibr Procedures Revised to Allow Recalibr at Facility.All Resistance Temp Detectors Will Be Replaced or Refurbished
ML20101K8537 December 1984Final Deficiency Rept Re Certification of Lead Auditor for Technical Metals,Inc.Initially Reported on 840524.Samples from Production Lots Remaining in Site Warehouse Chemically Analyzed & Found Acceptable
ML20101L5637 December 1984Supplemental Final Deficiency Rept Re Installation of 3-h Rated Hollow Metal Fire Door Frames.Initially Reported on 840525.Existing Caulking Replaced W/Approved Flame Retardant Adhesive SealantSafe Shutdown
ML20101N1877 December 1984Final Deficiency Rept Re Heat Numbers W/More than One Pipe Schedule.Initially Reported on 831213.Two Piping Spool Pieces Replaced W/Correct Schedule of Pipe.Exam of All Installations of Subj Heats Revised to Prevent Recurrences
ML20101L3597 December 1984Final Deficiency Rept Re Lubricating Oil Piping Sys for Safety Injection Pumps & Centrifugal Charging Pumps. Initially Reported on 840717.Replacement of safety-related Equipment W/O QA Program Will Be Repeated Per QA Program
ML20101M1037 December 1984Final Deficiency Rept Re ITE-Gould Containment Cooling for Mechanical Interlocks.Initially Reported on 840316. Instruction Manual Revised to Change Installation Instructions of Size 5 Mechanical Interlock Assembly
ML20101D3015 December 1984Forwards Status Rept for Oct & Nov 1984 Re 10CFR50.55(e) & Part 21 Items
ML20100R5131 December 1984Final Deficiency Rept Re Standby Diesel Generator Lube Oil keep-warm Pumps Supplied by Crane-Deming.Pumps Will Be Designed for Reliability.Interim Pumps Reliable for Use Until ASME Rated Pumps Available
ML20100C11619 November 1984Deficiency Rept Re Pressurizer PORVs Preoperational Test Discrepancies.Special Operations Procedure Will Be Performed to Resolve Existing Test Discrepancies
ML20099K78016 November 1984Final Part 21 & Deficiency Rept Re Turbine Driven Auxiliary Feedwater Pump Governor Valve Stem Guide Bushings.Initially Reported 841017.Investigation Revealed That Defictive Parts Described by Terry Corp Installed at Facility
ML20099K82913 November 1984Final Part 21/deficiency Rept Re Pressurizer PORV Failing to Close During Preoperational Test.Initially Reported 841011. Resolution Will Be Provided by 841119Loop seal
Stroke time
ML20099H1609 November 1984Final Deficiency Rept Re ex-core Neutron Detector Field Cabling.Initially Reported on 841009.All Damaged Triaxial Cables & Connectors Repaired &/Or Replaced.All Insulation Panels Verified to Be Properly Reinstalled