ML20081E089

From kanterella
Jump to navigation Jump to search
Advises That Since Guidance Contained in Reg Guide 1.97 Not Addressed in Submittals Re Generic Ltr 82-33,further Clarification of Position Re Compliance W/Generic Ltr Appropriate,Per .Ltr Will Be Submitted by 901215
ML20081E089
Person / Time
Site: Arkansas Nuclear  Entergy icon.png
Issue date: 07/31/1990
From: Ewing E
ENTERGY OPERATIONS, INC.
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
RTR-REGGD-01.097, RTR-REGGD-1.097 GL-82-33, NUDOCS 9008060146
Download: ML20081E089 (2)


Text

- _. _ _ _ - _ - _ - - _ . _ - .

=;ent.

FCJe 3 lb 137G 1

. 8 OnS  %% An moi h6(01 M 4 3100 i

July 31,1990 DCAN079027 U. S. Nuclear Regulatory Commission Document Control Desk Mail Station P1-137 Washington, D. C. 20555

$UBJECT: Arkansas Nuclear One - Units 1 and 2 Docket Nos. 50-313/50-368 License Nos. OPR-51 and NPF Clarification of Generic letter 82 33 Gentlemen:

In a letter dated June 13,1990(OCAN069011), ANO committed to perform an evaluation to determine if further clarification of its position regarding '

compliance with Generic Letter 82-33 was necessary.

The initial evaluation, which has been completed, compared AN0s commitment to the Generic Letter with the guidance contained in Regulatory Guide 1.97 to identify the portions of that guidance which had not been addressed by ANO.

ANO has concluded that, since all of the guidance contained in Regulatory Guide 1.97 was not addressed in its submittals regarding-Generic letter 82-33, further clarification of its position with respect to compliance with the Generic Letter is appropriate.

Therefore, ANO will submit a letter by December'15, 1990, describing which portions of the guidance contained in Regulatory Guide 1.97 were not addressed by its Generic Letter 82-33 submittals, and what actions, if any, will be completed to address these items.

9008060146 900731 PDR ADOCK 05000313 P PDC M83 o J

NRC Page 2 July 31, 1990 If you have any questions or comments, please contact Mr. James Fisicaro at 501-964-3228.

Very truly yours.

[

/

E. . Ewing General Manager, ,

Assessment ECE/RHS/sgw cc: Regional Administrator Region IV U. S. Nuclear Regulatory Commission 611 Ryan Plaza Drive, Suite 1000 Arlington, Texas 76011

. __ , _ _ . . - . . .