Monthly Operating Repts for May 1991 for Prairie Island Generating Plant
ML20079C218
Person / Time
Site: Prairie Island  Xcel Energy icon.png
Issue date: 05/31/1991
From: Dugstad D, Parker T
NORTHERN STATES POWER CO.
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
NUDOCS 9106190079
Download: ML20079C218 (9)


Text

m A ._. _ . - , , -

, . g

. Northem States Power Company 414 Nicollet Mall Minneapolis, Minnesota 55401 1927 Telephone (612) 330 5500 June 12, 1991 Prairie Island Technical Specifications Section 6.7.A.3 l US Nuclear. Regulatory Commission Attni Document Control Desk

% shington, DC 20555 PRAIRIE ISLAND NUCLEAR GENERATING PLANT Docket No. 50 282 License No. DPR-42 50-306 DPR-60 Monthly Operating Report i

May. 1991 Attached is the Monthly Operating Report for May, 1991 for the Prairie Island Generating Plant, v 3/ .j S(. Ldh IC6 jThomasMParker Manager Nuclear Support Service TMP/mk1 C: Director, Office of Resource Management Regional Administrator-III, NRC NRR Project Manager, NRC NRC Resident Inspector MPCA Attn: J W Ferm n Attachment l

I 910o1900'/9 910531 PDR ADOCK 05000282 0' R PDR gt-f I l

._. _ . __ _ . .. ._. .___ _ _ . _ . _ ._. _ _ _ _ _. _ ___ _ _.m__. _ _ -.m_ _ ._ . _ _ _ _

4 v .

l N o fi R o II V E _ S U d d o R L D E _ Q E E R o llN G _ E X EER I E N C E  !

l l

DOCKET NO. 50-282 UNIT PRAIRIE ISLAND N0,.1 l' DATE JUNE 4, 1991 g COMPLETED DY DALE DUGSTAD TEl.EPHONE 612-380--i121-4376 i L

I NONIU1 do L _ __._ _1221_._

l l i

l

- Unit One was operating in coastdown condliion. I t

On the first the NPDES perrait allowed cooling tower blowdown to in-crease to-300 cfr. 1

t. l On the ninth the norina l and redundant channels of heat iracing for the 1 boric acid storage tank to SI purnp suction failed. This put the Unit in a )

l six hour acilon staternent. Repa i rs were cornp le t ed before the Unit would i have had to s1 art an orderty shutdown.

On the fourteenth an NUE was declared at 0958 due to the failure of the ERCS cornputer in conjunction with a inajor portion of ihe BOP annuriclators 1 being out of service. The ERCS cornputer was returned to service at 0932 which ended the NUE.

l. During the second half of the anonth a stearn generator-tube leak was L detected.- Ii-increased to about 0.0059 pin and then becarne steady. It

! will be repaired-during the outage.

p'

,. Cyc le. fi f teen ref ueling_and snaintenance outage started at 2iOB of the-l' thirty-fi*st when the generator was taken off line. The reactor was non-l . critical at 2307. The outage is scheduled to last 26 to 29 days.

(

! This ended a continuous operating run of about 109 days.

y 1

l 1

l l-

_ CURRENT- ._ CONTINUOUS _0PERATING RUN OF 000 _ DAYS._ _ __

l l

L l

-. . - . . - - . ....- -.. . . . ~ . . - . . . - .~ __.. .--

a 6VEBoGE_ DOILY _UtlII_EDWEU_LEYEL DOCKET NO. 50-282 UNIT PRAIRIE ISLAND N0,1_

DATE JUNE 4, 1991 COMPLETED DY DALE DUGSTAD TELEPHONE 612-388-1121-4376 UDNIU1_ day ______ _1221 _ j D0Y AVEBoGE_ DOILY _ COWER LEVEL _.1dWExt4EIl i 472 2 A69 l 3 462 l 4 455 1 5 527 I 6 363 -l 7 437 '

8 434 I 9 429 ,

10 425 l ii 418 '

12- 409 i 13 400 14 394

15. 385 16 370 17 383 18 375 19 372 20 360

-21 351 22 339 23 330 24 330

'25 314 26 326 .

27 313 28 295 29 298 30 291 31 234 AVERAGE LOADS ABOVE 503 HWE-NET ARE DUE i

TO COOLER CONDENSER CIRCULATING WATER l, '

.....-..-.;....---..,. _ . - - - - . , ..----.-:..z.._-.-.

- . ~ _ . . - - . _ . . - , . _ . . . - . . . - - . . . , . ~ - . ,

  • . . a OEEBoIING_ Dolo GEEORI i

1 DOCKET NO. 50-202 UNIT PRAIRIE ISLAND N0.1 DATE JUNE 4, 1991 )

COMPLETED BY DALE DUGSTAD j TELEPHONE 612-308-ii21-4376 l DEERoIING_SleIUS  ;

l

1. UNIT NAME: EBoIBIE_ISLoND UU._1 l

-2.= REPORTING PERIOD:_doY__ __ 1221_ _ l

3. LICENSED THERMAL POWER (MWT) 1650 l
4. NAMEPLATE RATING (GROSS MWE) 593
5. DESIGN ELECTRICAL RATING (NET MWE) 530
6. NAXIMUM DEPENDABLE-CAPACITY (GROSS MWE) 534
7. MAXIMUM DEPENDADLE CAPACITY (NET MWE)- 503 l

,0. IF CHANGES OCCUR IN CAPACITY RATINGS (ITEi1S NUMDER 3 THROUGH 7)

SINCE LAST REPORT GIVE REASON. UDNE__ _______.___ _..___ ____- _ __

9. POWER LEVEL TO WHICH RESTRICTED, IF ANY-(NET MWE) _UQNE_ ___. _____ _

i

10. REASONS FOR RESTRICTIONS, IF ANY: _UQUE_._______ __ _ ___. __________

IHIS_dONIU YB:IO:DoIE CUbuloIIVE l I

i1. HOURS IN-REPORTING PERIOD 744 3623 153023 l 12..NUMDER OF HOURS REACTOR WAS CRITICAL 743.1 3622.1 130582.0 l

13. REACTOR. RESERVE-SHUTDOWN HOURS 0.0 0.0 5571.1 l
14. HOURS GENERATOR ON-LINE 741.1 3620.1 129032.8 l
15. UNIT RESERVE SHUTDOWN HOURS. 0.0 0.0 0.0
16. GROSS THERMAL ENERGY GENERATED (MWH) 934638 5619291 203201445- ^

l 171 GROSS ELECTRICAL ENERGY GENERATED (MWH) 305550 1870760 66733670 l- 18.-NET ELECTRICAL ENERGY GENERATED (MWH) 282434 1766790 62649801 l

.19.-UNIT.. SERVICE FACTOR .

99.6 99.9 84.3 l

20.--UNIT-AVAILABILITY FACTOR 99.6 99.9' B4.3 p 21. UNIT CAPACITY FACTOR (USING.MDC NET) 75.5 97.0' 81.4 l; 22. UNIT-CAPACITY FACTOR (USING DER NET) 71.6 92.0 77.2-

23. UNIT FORCED OUTAGE RATE 0.0 0.0 5.5 2 4 ~. FORCED OUTAGE HOURS -0.0 0.0 7540.3
25. SHUTDOWNS SCHEDULED OVER NEXT 6 MONTHS (TYPE, DATE & DURATION OF EACH) . ,

L ___8EEUELING_oND_doINIENoNCE_ QUI 6GE_SI68IING_0tLJUNE_5 _E08 26_D6YS____

l

26. IF CURRENTLY SHUTDOWN ESTIMATED STARTUP DATE: _ _ __ _NZo____ ________ ,

i l

l l

1 1

.-,r - . _ , . . , . - - , , . _ , . . . , . . . ~ , . _ . . _ . , , -

,__.-.._.,,,,.,,,.,.,,..m..~ -

.,_.,..,y,.,u. . . . _ , . .

. . . . _ ~ . - . . . . . .- ---. .. - --..-. -- . .~.. -. -.- . - .- -

UNII_SUUIDOWUS_6ND_E0WER_REDUCI1ON DOCKET NO 50-202 UNIT NAME EBoIBIE_1SLAND_dO._1 l DATE jut $_d1_1221 _ ...  !

I COMPLETED DY D6LE_DUGSIAD,_ ___

TELEPHUNE 612-388-1121-4376 l d001U1_doY_..___ _._1221_ __._ j l

l DAIE IYEE UGURS BEoS0tf UEIUDD LER_tlUdDER SYSIEd CodEONENI i YY/MM/DD 000,0 91/05/31 s 2.9 c 1 n/a n/a n/a P

IYEE BEoSON dEIUDD SYSIEd_ CODE-F-FORCED A-EQUIPMENT FAILURE i-MANUAL DRAFT IEEE STD S-SCHED -B-MAINTENANCE OR TEST 2-MANUAL TRIP 805-1984(P805-D5)

C-REFUELING 3-AUTO TRIP D-REGULATORY RESTRICTION 4-CONTINUED E-OPERATOR TRAINING & 5-REDUCED LOAD COMEONENI_ CODE LICENSE EXAMINATION 9-0THER i-F-ADMINISTRATIVE- IEEE STD 803A-1993 I

G-OPERATIONAL ERROR

( H-0THER

-...~..,u.._...2.__...~..._u. _ . . . _ . . . _ _ . . _ - _ _ _ _ . _ . _ . .-- - .. . . _ _ _

N o B B o I I V E _ E U t$ t16 B L D E _. D E' E B e l l t4 G _X X E E ll l E N C E DOCF:ET NO. 50-306 UNIT PRAIRIE ISLAND U0.2 DATE JUNE 4, 1991 COMPLETED DY DALE DUGSTAD T EL.EPii0NE 61? ' -308-1121 -4 376 N 0 tl T l h ._ ti o Y _ _ . _ _ ..- _12 21_

Unit Two was t,ase loaded this ru o n t h ; ther e were no shutdowns.

On the firri the NPDES pertnit allowed cooling tower blowdown to in-crease to 300 cfs.

CURRErlT CONTINU0US OPERATING RUN OF 152 DMS.

I 1

1

j A V E E o G E .D o l L Y._ U tl l I _ E 0 W E ls _ L E V E L DOCKET NO. 50--306 UNIT PRAIRIE ISLAND UO<2_

DATE JUNE 4, 1991 CuriPLETED BY DALE DUGSTAD TELEPHONE 6?' -309--i 121 -4376 t10tlIlk._MAY.______-__._1291_._.

DOY 6YEBOGE .D61LY-_ COWER. LEVEL._It1WErt4 Ell i 514

' 517 3 515 4 514 5 515 6 510 7 Si6 0 516 9 515 10 510 11 512 12 506 13 506 14 506 15 501 16 503 17 511 10 507 19 512 20 Sii 21 501 22 50i 23 502 24 503 25 504 26 505 27 504 20 500 29 502 30 499 31 503 AVERAGE LOADS ADOVE 500 tiWE-NET ARE DUE TO COOLER CONDENSER CIRCULATING WATER

l .

OECB6IItJG_. doi 6 BECOBI DOCKET NO. 50--306 UNIT PRAIRIE ISLAND t10.2_

DATE JUNE 4, 1991 C OM PLE T E~) BY DALE DUGSTAD TELEPHONE 612-388-1121-4376 DECR6Ili1G_SIAIUS

1. UNIT NAME: EBGIBIE ISLot3D t10 _2
2. REPORTING PERIOD:_d6Y_._._ _ 1221___
3. LICENSED THERMAL POWER (MWT)- 1650
4. NAMEPLATE RATING (GROSS MWE): 593
5. DESIGN ELECTRICAL RATING (NET MWE) 530
6. MAXIMUM DEPENDABLE CAPACITY (GROSS MWE) 531
7. MAXIMUM DEPENDADLE CAPACITY (NET MWE) 500
8. IF CHANGES OCCUR IN CAPACITY RATINGS (ITEMS NUMBER 3 THROUGH 7)

SINCE LAST REPORT GIVE REASON: . N Q ti E _ .. ._ _ _. _ _ _ _ _ _ _ ._ _ _ . ._ _ _ . _ _ _. _

9. POWER LEVEL TO WHICH RESTRICTED, IF ANY (NET M W E ) _ _ tJ 0 t4 E _. _ _ ._ _ _ ._ . . _
10. REASONS FOR RESTRICTIONS, IF ANY:.__N0NE_.__ _ ____.__.__.._ .__ __ .._

IUIS._d0tlIU XB:10:D6IE CUdVL6IIVE 1i. HOURS IN REPORTING PERIOD 744 3623 144141

12. NUMBER OF HOURS REACTOR WAS CRITICAL 744.0 3623.0 127310.4
13. REACTOR RESERVE SHUTDOWN HOURS 0.0 0.0 1516.1
14. HOURS GENERATOR ON-LINE '744.0 3623.0 125994.5
15. UNIT RESERVE SHUTDOWN HOURS 0.0 0.0 0.0
16. GROSS THERMAL ENERGY GENERATED (MWH) 1224602 5877673 199344671
17. GROSS ELECTRICAL ENERGY GENERATED (MWH) 401490 1952270 64731600
10. NET ELECTRICAL ENERGY GENERATED (MWH) 3'77994 10500/4 61211565
19. UNIT SERVICE FACTOR 100.0 100.0 07.4
20. UNIT AVAILABILITY FACTOR 100.0 100.0 87.4
21. UNIT CAPACITY FACTOR (USING MDC NET) 101.6 102.1 84.9
22. UNIT CAPACITY FACTOR (USING DER NET) 95.9 96.3 80.1
23. UNIT FORCED OUTAGE RATE 0.0 0.0 3.0
24. FORCED OUTAGE HOURS 0.0 0.0 3964.0
25. SHUTDOWNS SCHEDULED OVER NEXT 6 MONTHS (TYPE, DATE 6 DURATION OF EACH)

___.._._____.____._____.___._tlZA._._____._.___.____._____...__...______

26. IF CURRENTLY SHUTDOWN ESTIMATED STARTUP D A T E ; _ _ . _._ _._tJ Z e _ _ _ _ _ _ _ _.._ _ _ _ _

.,r.-- ,

e - :- U N II _ S t.'UI D O W N S _6 tf D..ED W E B _8 E D U C I I 0 tf

,_ DOCKET f0 S0-306_

UNIT NAME E861RIE_1SLGND NO. 2 DATE JUNE _L_.1221_____

COMPLETED BY. DOLE DUGS 16D_ _ .__

TELFPHONE. 612-300-1121-4326 l

NONIH1_.doY..___ __._1221__ _

D6IE IYCE' UQUBS BE6 SON MEIURD LE8_tiudBEB SYSIEd C0dEONESI YY/MM/DD 090.0 91/05/01 n o .ie

(..  :

I

.IYEE: BFoSON METHOD SYSIEd. LODE

.F-FORCED .A-EQUIPMENT FAILURE 1-MANUAL DRAFT IEEE STD S-SCHED 'B-MAINTENANCE OR 1ESr 2-MANUAL TRIP 005-1984(P905-D5)

C-REFUELING 3-AUTO TRIP D-REGULATORY RESTRICTION 4-CONTINUED l E-OPERATOR TRAINING a 5-REDUCED LOAD CildEONENI_ CODE l LICENSE EXAMINATION 9-0THER F-ADMINISTRATIVE IEEE STD 803A-1993 G-OPERATIONAL' ERROR H-0THER