~ < w :. - , _ ,

o.m .

ni mCHMEN_ G LAr. 15co.c~

LICENSEE EVENT REPORT ptev 2 m.EAsa esist on -vre ALL accusato iN7eMT-g 12, GM cowinct.stecc I I l  ! I I l@

,' 'j l 'l l L I L 15 IC I1 **

l@l0101010vCanstavuses 1 010l0l0loi010!@lLI1!010 a :s 1 0!@lsi c.Ar wct=st -n s .c l I sa @

s s ucausas c ct is cere?

io6iI gl L@lof 51 O! 01 01 31 71 3@l 64O! s9411 19 Ev tMT CATE

! 8 ! 2 l@[ o 7*-I 6 loM EFCMT 4

I 1 ILAT6IE c"L40l@

4 60 Si DOCKET Ni a.41A EVENT CE5CRimCN AND PRCSA8LE CONSECUENCE3 h

[o i:1 i On April 19, 1982 the Station Vent Stack Flow Recorder was readino downscale. (

C42; l Based on known operatina conditions the stack flow was esti nated to Se 300,000Cfm. i

,,,,, ; At the time of this event, fuel was being loaded for the first time. Safe operation;

,o,3, 9 of the Unit was maintained at all tirnss.  ;

I o . e_ }. [. ..

i I o i il 1 I

o>etI no sVTIYM CAust CAus$ Cone. VALyg CODE CCat su&COCE CDMPCMENT COCg e iam sWSCDOf oi,1 IM IB

. to l@ l El@ l Elh l ll NI Sl Tl Rll.flh l T{@ l 21@

i. 22 is i. i.  :=

secus=TiAt oc: in ntacE =mser avvision tve>eveAn meroprT wo. as twg =c.

@ lts,f.oyg,gl E

8l2l l-l 1 01 0! 2! ld l 01 3 l IL1 l-4 1 0l t =

W '

n =

2 2s 22 :s

s so si e IAKIT C T M 2 WQuRS sWTTO POR S. EV e4AT.m CQ gM

~#

l:s B QW@ x

[a Z l@ lZ

.m lh Lolofo@fofLvJ@22 .o ai lo N[@ lo A l@ l H l 1 l 2 l 4 l@ - , , .

CAUSE OE50RimON AND CORRECTIVE AC"nCNS h l i 4 a.i i it was determined that the flow transmitter had #ailad and canced the recorder to i The flow transmitter was reoaired and the Station V,nt hark f t i i i 1. ; read downscale.

,,.7i) Flow Recorder was declared operable at 2040 on Anril 20. 1982. l 1 iici L l

It iAi l_

's- E sacwem cratasTATus h NNav' cascoverre casemenow @

Work Request [

Iiis ) Wh bI .

gg O IO!hln Na l l.aA l@l

.s go 7

ag, 12 LaCATiose er artsAsa h AucuuTca i art.zAser ca arttAss NA menvity h l .l NA l l i I s:l el O l @ lio0 l@l 7 si

.e ,o pensomet execsuars muustm twt CEs0mP?iCN 16 7 l l O ! 01 O j@l Zl@l NA l so

'

  • er.sem, e'u'. uu'.'ies

~

muusen ecsemnem@ l.

NA li la 4I el O! 01 Olhl 7 il 12 go LOE3 CF C4 CAMACE TO **QUTV -

i Tv't OtscmeT om ,

.I fnTl. I, Z!@l,e NA

  • umC:Tv 8205200082 820507 Nac uSE ONLY
  • a:su r- :ts:" PDR ADOCA 0S000373 IIIIIIIIIIIIl5 l li: IoeiNfhl S PDR I

.~-.c,.e.we= ~

- ,-cr.s: V  %& W) X f

e

. ,y * ,"

l A. LER NUMBER 82-002/03L-0 B. LICENSEE NAME Commonwealth Edison Company C. FACILITY NAME LaSalle County Nuclear Station - Unit 1 D. DOCKET NUMBER 050-373 E. EVENT DESCRIPTION On April 19, 1982 the Control Room operator noticed the Station Vent Stack Flow Recorder, OFR-VRO19, was reading downscale. Based on known operating conditions the stack flow was estimated to be 300,000 cfm.

A work request was initiated to investigate and correct the problem.

F. PROBABLE CONSEQUENCES OF THE OCCURRENCE At the time of this event, LaSalle Unit One was undergoing initial fuel and there was no irradiated fuel on site. The probability of any radioactive releases to the environment at this time was negligible .

Therefore, the health and safety of the public was not affected. Safe operation of the Unit was maintained at all times and estimated stack flow readings were taken every four hours in accordance with Technical Specification 3.3.7.11.

G. CAUSE The cause of this occurrence was the flow transmitter core hung up at its zero point. This caused the recorder to read downscale. The flow transmitter was manufactured by Hays Republic, Model 252A.

H. CORRECTIVE ACTION A work request was initiated to correct the problem of the chart recorder reading downscale'. Under this work request.the flow transmitter was repaired and the Station Vent Stack Flow Recorder was declared operable at 2040 on April 20, 1982.

i i

--. - . . -