LER 83-033/03L-0:on 830402,during Hot Shutdown,Radwaste Effluent Monitor Declared Inoperable.Caused by High Fixed Level of Background Radiation.Liquid Radwaste PRM Inner Chamber Coated W/Acrylic Resin to Prevent Radiation Buildup
ML20023B805
Person / Time
Site: LaSalle Constellation icon.png
Issue date: 04/28/1983
From: Arand J
COMMONWEALTH EDISON CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
Shared Package
ML20023B801 List:
References
LER-83-033-03L, LER-83-33-3L, NUDOCS 8305060401
Download: ML20023B805 (2)


Text

. . . .- - - - .

s. m s .

s . LICENSEE EVENT REPORT

>. " CONTROL BLOCK: l 1 l l l l lh !PLEASE PRINT OR TYPE AL1. REQUIRED INFd."MATIONI' 1 6 31tl8 l9ll LI UCENsEE Ll SI Cl CCCE 1 l@l 14 015l 0 l - l 0 l 0VCENsF.l 0 lNWWE 0 l ER01 - l 0 l 0 26l@l264 l 1a.sCENSE l 0JOl@l$ 7 CAl T Se[g l 0 (0TYPE s l Eu","C l L l@l 01510101013171364j@l69 01410121813 EVENT CATE 74 GIO 75 1412 !818 I 3to]@

RE?QRT DATE 8 to S1 00CKET N6M8ER EVENT DESCRIPTION AND PRC8ABLE CCNSECUENCES O'o

,a4:, l On April 2,1983, wi th Uni t- One in hot shutdown, the radwaste effluent monitor was  ;

declared inoperable. Since the Rad / Chem department was double sampling each batch g

,,,3, ,

, , , , , ; discharge in accordance with T.S. 3.3.710, the health and safety of the public was  ;

l l

not affected.

g

,oi3, ;

l 13161I I

io 1: 1I I

i o is i I "

7 s9 E CDE su E COMPONENT CCDE suecodt sua E jotej 7 8 l MI toCl@in W@ l E l@ ll lN lS IT lR lU [h W@ 20W@

9 12 13 is as CCCuRRENCE ME* ORT REVfslo80 sEO,utNTIAL RE ORT NO. CCOE ' TYPE NO.

EVENTVEAR LE R

@ ,ajg/Ro 18131 21 22

[-]

23 101313i 24 25 M

27 10 1 31 28 29 W l_- ]

30 31 d

32 HOURS 22 50 t 50 sua. , Lt uA , cTuRgm T MET Wg [43A [g KN ,

~

lXl@[2_,j@ lZl@ lZl@ l010l0l0l [Y l@ l G l 0 [8 [0 [g JS

  • 36 33 40 44 41 44 47 33 34 CAUSE DESCRIPTION AND CORRECTIVE ACTIONS 27 li t o g l The cause of the PR,41 inoperable status was due to a high fixed level of background g

The liquid radwaste PRM's inner chamber surface was coated with an  ;

,,,,,l radiation.

g g ; acrylic resin, experimentally, to determine if the buildup in the level of background T'he liquid radwaste PRM was returned to service and is j

, , , ., , l radiation could be stopped.

,;,,,p presently functioning properly. . g 7 a e

%PCWER QTHER STATVs isCO v OtSCOVERY QESCRef'TICN sTA

'i 6 s I I Bl@ 101010ul@ln NA l [A,_j@lSourceCheck l a a

  • n 7

s g,,,,, g,,, tacAfion o, RnEm @ -

m euco or m ease AuouMTor NA Acnvify @ ll. NA l

l "

ii I s'*l I z, Rio~Nd

' l @ Lz._j@ses ex,os Nuo.cR Tv,c o sCRinioN@ l NA r i l 71 101 01 ol@L.zJ@l" .

' ,sRso~Nc N uh s

~u ..R cuminio~@ NA l.

t i t a l 101 01 Ol@l "

' h55,o' o" ?$',ch '^c" @ $o0'200$R2$$88$$3 S

0 NA PDR .]

iij,jlZlgl 7 8 9 10 e

, ess CE CRIPTION NA l. [;;;;;;;;;;;jy

~nTl' 'L381' (815)"357-6761 "'l J. Arand PHONE: $

NAME OF PREPARER

  • \

I. '

l. LER NUMBER: 83-033/03L-0
11. LASALLE COUNTY STATION: Unit i lli. DOCKET NUMBER: 050-373 IV. EVENT DESCRIPTION:

4 4 On April 2,1983, with Unit One in hot shutdown, the radwaste effluent monitor was declared inoperable.

'V.

PROBABLE CONSEQUENCES OF THE OCCURRENCE:

Since the Rad / Chem Department took two independent samples and performed two independent release rate calculations in accordance wi th T.S. 3.3.7.10 for each batch discharged, the concentration of radioactive material released f rom the site was limited to the concentrations specified in 10CFR20, Appendix B, Table 11, Column 2 Therefore, the health and safety of the public was not affected.

VI. CAUSE:

! The liquid radwaste effluent PRM was declared inoperable because an accept-able source check could not be perforned due to a relatively high level l of contamination on the chamber surface. LER 83-033/03L-0 was cau' sed by' the .same problem.

Vll. CORRECTIVE ACTION:

The liquid radwaste PRM Inner chamber surface was coated with an acrylic  !

resin, experimentally, to determine if the bulldup of contamination could be prevented. The liquid radwaste PRM was returned to service and is presently functioning properly.

Prepared by: John Arand 3