ML19318A647

From kanterella
Jump to navigation Jump to search
LER 80-038/03L-0:on 800517,gaseous Waste tank,GW-TK-1A, Pressure Decreased from 18 to 6 Psig.Caused by Leaks on Flanges of Flow Orifice & Pressure Transmitter.Tanks Manually Isolated Until Maint & Testing Can Be Completed
ML19318A647
Person / Time
Site: Beaver Valley
Issue date: 06/16/1980
From: Lacey W
DUQUESNE LIGHT CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
Shared Package
ML19318A646 List:
References
LER-80-038-03L, LER-80-38-3L, NUDOCS 8006230562
Download: ML19318A647 (1)


Text

  • U. S. NUCLEAR REGULATORY COMMISSitN festC P OM M 364 ~ ,

tr m

. LICENSEE EVENT REPORT coNTROLsLOCx:l l l l 1 l

.h l (PtEASE PRINT OR TYPE ALL REQUIRED !NPORMATION) l l

@ l 8P9 l A lLICENSEE l

B l VCoOE l S l 1 l@l 0 l 0 l- l 0 LiCEt4ENuwsEA le tt l0 l 0 l 0 l 0 l- l0 l 025l@l4 ;6 l1LICENSE l1 11TvrE l 140l@lsiGATSd@

CON'T -

%8  % l L80@l 0 l 5 l 0OOCKET 6' l 0 l Nuualta 0 l 3 l 3 led4 @l 69 0EVENT l 5 DATE l 1 l 7 l 8 l 's0 @lREPoAT 14 0 lQ6ATEl 1161 80 Sl Ol@

EVENT DESCRIPTION AND PRC5 ABLE CONSEQUENCES h o l At 0300 hours0.00347 days <br />0.0833 hours <br />4.960317e-4 weeks <br />1.1415e-4 months <br /> on May 17, 1980, it was determined that Gaseous Waste Tank [GW-TK-1A] ;

gg pressure had decreased from 18 to 6 psig. Leak detection was immediately commenced.g o , l When sampled, no activity was detected in the af fected tank. All possible routes ofg g

g i release were monitored by effluent path and building monitors so the health and g l safety of the public was not affected. t l

o 7 l I l L,o LJ, ,l sysTEu CAust CAUSE , CoVP. VALV E CODE CCOE susC00E COMPONENT Co0E su8coCE suBC00E

)

o 9 8

I MI Bl@ G@ IZ l@ l IJZI ZI ZI ZI Zl Zi@ lZ l@ W @

9 .0 11 12 18 't 9 20 stoOENTIAL OCCURRENCE REPoMT REvistoN EVENT VE AR REPCRT No. CODE TYPE No.

LEA O sg/Roa 18l01 L _1 1 01 31 81 1-1 1 01 31 LtJ L-J lol 32 24 22 23 24 26 27 28 29 30 31 S. Su *L E MANUFACTURER 7 N AC oN PLANT utT MoVRs h s 8 T FCA

[jtj@[J,j@

J3 34 W@ l Zl@

JS 36 l 0l 01 Ol 0l 37 40 l,.N_j @

48 lNl@ lAl@ lZl9l919l@

42 43 44 47 CAUSE DESCRIPTION ANO CCRRECTIVE ACTICNS h lijoil Leaks were found on the flanges of a flow orifice and pressure transmitter for the 1 i l Gaseous Waste Surge Tank. Gas tanks were manually isolated until maintenance and I

, l 1eak_ testing can be completed. Due to the large number of construction jobs, it is I g l felt that the pipe was stepped on or sat on. l I

i 4 I

's " LEY vcwEa oTuta status @ 5'sEo'SSN oiscovEnv cEscaiPTioN @

l'IIII [_XJ@ l O l O l 0l@l Design l l A l@l Operator observation l l

' ' ' ' '2. " " "

  • a ACTiviTv co'4 TENT " gefric toCAT,cNo,.Eu.sg@

i a

.Eu Asto o, .Eu AsE l

Aocu~T N/A ACT,,,n @ I I N/A I LZ_l@ l Zi@ats

,E asoNNEl E.,os Nu .E. TV.E , Esc... Tion @

4 lTTTI 1010101@lZ j@l N/A a

I i

, .seNNEi.'.m'its Nu .E. CEsc i, Tion @

7 8 3 l010l0l@li2 11 N/A

. 80 l

'in ' "

'",^.r'o'N ' " @

N/A l 7

i 2 4 9 lZl@l to 30 OE .iPTioN

,  : o issydtL 81 N/A l llll!l1!!!lIl}

F 4 3 'O 64 69 80. ;

W . S. Lacey ,,an g . 412-643-1258 l

.gy,g E N

, 8ss 6 230 %2_ . .

. - _ m . .. - . . ~ _ _ . - _ - . _ , _ ..e --.