l17H - -

  • LICENSEE EVENT REPORT CONTROL DLOCK: l l l l l l lh 6

(PLEASE PRINT On TYPE ALL REQUIRED INFORMATION) lo Ill8 lP 7 9 l ALICENSEE l B lVCODE lS l 114l@l 0 l 0 l- l 0 LICENSL lb l 0 l 0NUVOLH l 0 l 0 l- l0 l 023l@[26 4 l1LICLNSL l1 l1T YPE l 1JGl@l$ 7 C lA T b8l@

CON'T 7

o 1 8

S$n"CE 60 Ql 640 l 5 l 0OOCKET l 0 lNUMUEH 0 l 3 l 3 l ul4 Ql 0 l 4EVENT G'>

l 3DATEl 0 l 7 l 9 @l0 74 7b l REPORT 9 l2 l1 l 7 980 l@

DATE EVENT DESCniPTION AND PROD ABLE CONSEQUENCES h l o 12 l l During performance of 18-month surveillance testing of 221 hydraulic snubbers, l o 3 23 snubbers were determined to have lock-up or bleed rate values outside of the l l acceptance criteria. Sik of these snubbers were on the spent fuci pool cooling l o 4 10 Isl I system and had not been tested or rebuilt during the last surveillance period. l lo Ic i l l o 7 l l 0 8 l l 60 7 8 9 SYSTE M CAUSE CAUSE COMP. VA LV E-CODE CoOE SUSCODE COMPONE NT CODE SUSCODE SUSCODE o 9 l x l x l@ LE_jh j @ l 5 l U l P l 0 l R lT lh [Djh l 3 l h 20 7 8 3 to 11 12 IJ 18 19 SEQUE NTI AL OCCURRENCE REPORT REVISION EVENT YE AR REPOHT NO. CODE TYPE N o.

LER h ng/RO RT l 7l 9l [-j 23 24 0l 3l 5l y 27 l0 l 3l 28 29 lLl 30 l-l 31

[0]

32 21 22 2G A EN AT ON PLANT M i HOURS SB IT D FOn d 8. SUPPLIEF MAN TACTURER lDl@lZl@

JJ 34 lSbZ l@ lZl@

3G l0 l0l0l0l 31 40 lNl@

41 42 Yl@ l43 Al@ 44 I l 2 l 0 l 747 l@

CAUSE DESCRIPTION AND CORRECTIVE ACTIONS li l o l ghe snubbers failed for various reasons, including air in the cylinder, wear ring l 1 lij problems, and handling damage while removing the snubbers. All of the failed snubbers l 3 7 l were rebuilt, purged, and tested satisfactorily.

i a l I i 4 I l

7 8 9 80 STA S  % POWEn OTHER ST ATUS I VF DISCOVERY DESCniPTION l115l l Clh l 0 l 0 l 0 l@l N/A l l B l@l Surveillance test l ACTIVITY CO TENT nELE ASED OF nELE ASE AMOUNT OF ACTIVITY LOCATION OF RELEASE N/A N/A l 7

1 c 8 9 W @ l Zl@l to 11 44 l l 45 80 PERSONNEL E xFOSUHES ,

NUMUF H TYPE DESCntPTION li l 7 l l 0 l 0 l 0 lhl Z lhl N/A l

' ' ' ,E n SON ~ d' t~ J'iES NuveE n otSCniPTiONh 7

i 4 8 9 l0l0l0l@l 11 12 N/A ,

80 l

L OSS OF OH OAVAGE 10 FACillTY A

PE Of SCHIPif 0N O i o [lj@l N/A 7 9 09 28OS/S l 60 7 6 s 10

"* Ti sCniPiiON e N/A 103515f llllllll

""= "

l l l l :2

? o inU.EL 81 .

I G8 69 80. E 7 el J 'O NAME Or PHEPAH[ H _ _ PHONE: