RESRAD, Version 7.0 T1/2 Limit = 30 days 12/06/2014 16:11 Page 1 Summary : Zion Subsurface Soil 3,000 m^2 120614 File : C:\\RESRAD_FAMILY\\RESRAD\\7.0\\USERFILES\\ZION SUBSURFACE SOIL DCGL.RAD Table of Contents Part I: Mixture Sums and Single Radionuclide Guidelines Dose Conversion Factor (and Related) Parameter Summary... 2 Site-Specific Parameter Summary.......................... 4 Summary of Pathway Selections............................ 8 Contaminated Zone and Total Dose Summary................. 9 Total Dose Components Time = 0.000E+00.................................... 10 Time = 1.000E+00.................................... 11 Time = 3.000E+00.................................... 12 Time = 1.000E+01.................................... 13 Time = 3.000E+01.................................... 14 Time = 1.000E+02.................................... 15 Time = 3.000E+02.................................... 16 Time = 1.000E+03.................................... 17 Dose/Source Ratios Summed Over All Pathways.............. 18 Single Radionuclide Soil Guidelines...................... 18 Dose Per Nuclide Summed Over All Pathways................ 19 Soil Concentration Per Nuclide........................... 19

RESRAD, Version 7.0 T1/2 Limit = 30 days 12/06/2014 16:11 Page 2 Summary : Zion Subsurface Soil 3,000 m^2 120614 File : C:\\RESRAD_FAMILY\\RESRAD\\7.0\\USERFILES\\ZION SUBSURFACE SOIL DCGL.RAD Dose Conversion Factor (and Related) Parameter Summary Dose Library: Subsurface Soil DCGL 120614 Plus FGR 11 Current Base Parameter Menu Parameter Value# Case* Name HHHH A-1 DCF's for external ground radiation, (mrem/yr)/(pCi/g)

A-1 Ba-137m (Source: FGR 12) 3.606E+00 3.606E+00 DCF1( 1)

A-1 Co-60 (Source: FGR 12) 1.622E+01 1.622E+01 DCF1( 2)

A-1 Cs-134 (Source: FGR 12) 9.472E+00 9.472E+00 DCF1( 3)

A-1 Cs-137 (Source: FGR 12) 7.510E-04 7.510E-04 DCF1( 4)

A-1 Ni-63 (Source: FGR 12) 0.000E+00 0.000E+00 DCF1( 5)

A-1 Sr-90 (Source: FGR 12) 7.043E-04 7.043E-04 DCF1( 6)

A-1 Y-90 (Source: FGR 12) 2.391E-02 2.391E-02 DCF1( 7)

B-1 Dose conversion factors for inhalation, mrem/pCi:

B-1 Co-60 2.190E-04 2.190E-04 DCF2( 1)

B-1 Cs-134 4.620E-05 4.620E-05 DCF2( 2)

B-1 Cs-137+D 3.190E-05 3.190E-05 DCF2( 3)

B-1 Ni-63 6.290E-06 6.290E-06 DCF2( 4)

B-1 Sr-90+D 1.308E-03 1.300E-03 DCF2( 5)

D-1 Dose conversion factors for ingestion, mrem/pCi:

D-1 Co-60 2.690E-05 2.690E-05 DCF3( 1)

D-1 Cs-134 7.330E-05 7.330E-05 DCF3( 2)

D-1 Cs-137+D 5.000E-05 5.000E-05 DCF3( 3)

D-1 Ni-63 5.770E-07 5.770E-07 DCF3( 4)

D-1 Sr-90+D 1.528E-04 1.420E-04 DCF3( 5)

D-34 Food transfer factors:

D-34 Co-60, plant/soil concentration ratio, dimensionless 1.500E-01 8.000E-02 RTF( 1,1)

D-34 Co-60, beef/livestock-intake ratio, (pCi/kg)/(pCi/d) 5.800E-02 2.000E-02 RTF( 1,2)

D-34 Co-60, milk/livestock-intake ratio, (pCi/L)/(pCi/d) 2.000E-03 2.000E-03 RTF( 1,3)

D-34 D-34 Cs-134, plant/soil concentration ratio, dimensionless 7.800E-02 4.000E-02 RTF( 2,1)

D-34 Cs-134, beef/livestock-intake ratio, (pCi/kg)/(pCi/d) 6.500E-02 3.000E-02 RTF( 2,2)

D-34 Cs-134, milk/livestock-intake ratio, (pCi/L)/(pCi/d) 1.400E-02 8.000E-03 RTF( 2,3)

D-34 D-34 Cs-137+D, plant/soil concentration ratio, dimensionless 7.800E-02 4.000E-02 RTF( 3,1)

D-34 Cs-137+D, beef/livestock-intake ratio, (pCi/kg)/(pCi/d) 6.500E-02 3.000E-02 RTF( 3,2)

D-34 Cs-137+D, milk/livestock-intake ratio, (pCi/L)/(pCi/d) 1.400E-02 8.000E-03 RTF( 3,3)

D-34 D-34 Ni-63, plant/soil concentration ratio, dimensionless 9.200E-02 5.000E-02 RTF( 4,1)

D-34 Ni-63, beef/livestock-intake ratio, (pCi/kg)/(pCi/d) 5.000E-03 5.000E-03 RTF( 4,2)

D-34 Ni-63, milk/livestock-intake ratio, (pCi/L)/(pCi/d) 3.200E-02 2.000E-02 RTF( 4,3)

D-34 D-34 Sr-90+D, plant/soil concentration ratio, dimensionless 5.900E-01 3.000E-01 RTF( 5,1)

D-34 Sr-90+D, beef/livestock-intake ratio, (pCi/kg)/(pCi/d) 8.000E-03 8.000E-03 RTF( 5,2)

D-34 Sr-90+D, milk/livestock-intake ratio, (pCi/L)/(pCi/d) 2.700E-03 2.000E-03 RTF( 5,3)

D-5 Bioaccumulation factors, fresh water, L/kg:

D-5 Co-60, fish 3.000E+02 3.000E+02 BIOFAC( 1,1)

D-5 Co-60, crustacea and mollusks 2.000E+02 2.000E+02 BIOFAC( 1,2)

D-5 D-5 Cs-134, fish 2.000E+03 2.000E+03 BIOFAC( 2,1)

D-5 Cs-134, crustacea and mollusks 1.000E+02 1.000E+02 BIOFAC( 2,2)

RESRAD, Version 7.0 T1/2 Limit = 30 days 12/06/2014 16:11 Page 3 Summary : Zion Subsurface Soil 3,000 m^2 120614 File : C:\\RESRAD_FAMILY\\RESRAD\\7.0\\USERFILES\\ZION SUBSURFACE SOIL DCGL.RAD Dose Conversion Factor (and Related) Parameter Summary (continued)

Dose Library: Subsurface Soil DCGL 120614 Plus FGR 11 Current Base Parameter Menu Parameter Value# Case* Name HHHH D-5 Cs-137+D, fish 2.000E+03 2.000E+03 BIOFAC( 3,1)

D-5 Cs-137+D, crustacea and mollusks 1.000E+02 1.000E+02 BIOFAC( 3,2)

D-5 D-5 Ni-63, fish 1.000E+02 1.000E+02 BIOFAC( 4,1)

D-5 Ni-63, crustacea and mollusks 1.000E+02 1.000E+02 BIOFAC( 4,2)

D-5 D-5 Sr-90+D, fish 6.000E+01 6.000E+01 BIOFAC( 5,1)

D-5 Sr-90+D, crustacea and mollusks 1.000E+02 1.000E+02 BIOFAC( 5,2)

  1. For DCF1(xxx) only, factors are for infinite depth & area. See ETFG table in Ground Pathway of Detailed Report.
  • Base Case means Default.Lib w/o Associate Nuclide contributions.

RESRAD, Version 7.0 T1/2 Limit = 30 days 12/06/2014 16:11 Page 4 Summary : Zion Subsurface Soil 3,000 m^2 120614 File : C:\\RESRAD_FAMILY\\RESRAD\\7.0\\USERFILES\\ZION SUBSURFACE SOIL DCGL.RAD Site-Specific Parameter Summary User Used by RESRAD Parameter Menu Parameter Input Default (If different from user input) Name HHHHH R011 Area of contaminated zone (m**2) 3.000E+03 1.000E+04 --- AREA R011 Thickness of contaminated zone (m) 1.000E+00 2.000E+00 --- THICK0 R011 Fraction of contamination that is submerged 0.000E+00 0.000E+00 --- SUBMFRACT R011 Length parallel to aquifer flow (m) 6.180E+01 1.000E+02 --- LCZPAQ R011 Basic radiation dose limit (mrem/yr) 2.500E+01 3.000E+01 --- BRDL R011 Time since placement of material (yr) 0.000E+00 0.000E+00 --- TI R011 Times for calculations (yr) 1.000E+00 1.000E+00 --- T( 2)

R011 Times for calculations (yr) 3.000E+00 3.000E+00 --- T( 3)

R011 Times for calculations (yr) 1.000E+01 1.000E+01 --- T( 4)

R011 Times for calculations (yr) 3.000E+01 3.000E+01 --- T( 5)

R011 Times for calculations (yr) 1.000E+02 1.000E+02 --- T( 6)

R011 Times for calculations (yr) 3.000E+02 3.000E+02 --- T( 7)

R011 Times for calculations (yr) 1.000E+03 1.000E+03 --- T( 8)

R011 Times for calculations (yr) not used 0.000E+00 --- T( 9)

R011 Times for calculations (yr) not used 0.000E+00 --- T(10)

R012 Initial principal radionuclide (pCi/g): Co-60 1.000E+00 0.000E+00 --- S1(1)

R012 Initial principal radionuclide (pCi/g): Cs-134 1.000E+00 0.000E+00 --- S1(2)

R012 Initial principal radionuclide (pCi/g): Cs-137 1.000E+00 0.000E+00 --- S1(3)

R012 Initial principal radionuclide (pCi/g): Ni-63 1.000E+00 0.000E+00 --- S1(4)

R012 Initial principal radionuclide (pCi/g): Sr-90 1.000E+00 0.000E+00 --- S1(5)

R012 Concentration in groundwater (pCi/L): Co-60 not used 0.000E+00 --- W1( 1)

R012 Concentration in groundwater (pCi/L): Cs-134 not used 0.000E+00 --- W1( 2)

R012 Concentration in groundwater (pCi/L): Cs-137 not used 0.000E+00 --- W1( 3)

R012 Concentration in groundwater (pCi/L): Ni-63 not used 0.000E+00 --- W1( 4)

R012 Concentration in groundwater (pCi/L): Sr-90 not used 0.000E+00 --- W1( 5)

R013 Cover depth (m) 0.000E+00 0.000E+00 --- COVER0 R013 Density of cover material (g/cm**3) not used 1.500E+00 --- DENSCV R013 Cover depth erosion rate (m/yr) not used 1.000E-03 --- VCV R013 Density of contaminated zone (g/cm**3) 1.800E+00 1.500E+00 --- DENSCZ R013 Contaminated zone erosion rate (m/yr) 1.500E-03 1.000E-03 --- VCZ R013 Contaminated zone total porosity 3.500E-01 4.000E-01 --- TPCZ R013 Contaminated zone field capacity 6.600E-02 2.000E-01 --- FCCZ R013 Contaminated zone hydraulic conductivity (m/yr) 2.880E+03 1.000E+01 --- HCCZ R013 Contaminated zone b parameter 9.700E-01 5.300E+00 --- BCZ R013 Average annual wind speed (m/sec) 4.200E+00 2.000E+00 --- WIND R013 Humidity in air (g/m**3) not used 8.000E+00 --- HUMID R013 Evapotranspiration coefficient 6.250E-01 5.000E-01 --- EVAPTR R013 Precipitation (m/yr) 8.300E-01 1.000E+00 --- PRECIP R013 Irrigation (m/yr) 1.900E-01 2.000E-01 --- RI R013 Irrigation mode overhead overhead --- IDITCH R013 Runoff coefficient 2.000E-01 2.000E-01 --- RUNOFF R013 Watershed area for nearby stream or pond (m**2) 1.000E+06 1.000E+06 --- WAREA R013 Accuracy for water/soil computations 1.000E-03 1.000E-03 --- EPS R014 Density of saturated zone (g/cm**3) 1.800E+00 1.500E+00 --- DENSAQ R014 Saturated zone total porosity 3.500E-01 4.000E-01 --- TPSZ R014 Saturated zone effective porosity 2.900E-01 2.000E-01 --- EPSZ R014 Saturated zone field capacity 6.600E-02 2.000E-01 --- FCSZ

RESRAD, Version 7.0 T1/2 Limit = 30 days 12/06/2014 16:11 Page 5 Summary : Zion Subsurface Soil 3,000 m^2 120614 File : C:\\RESRAD_FAMILY\\RESRAD\\7.0\\USERFILES\\ZION SUBSURFACE SOIL DCGL.RAD Site-Specific Parameter Summary (continued)

User Used by RESRAD Parameter Menu Parameter Input Default (If different from user input) Name HHHHH R014 Saturated zone hydraulic conductivity (m/yr) 2.880E+03 1.000E+02 --- HCSZ R014 Saturated zone hydraulic gradient 3.900E-03 2.000E-02 --- HGWT R014 Saturated zone b parameter not used 5.300E+00 --- BSZ R014 Water table drop rate (m/yr) 0.000E+00 1.000E-03 --- VWT R014 Well pump intake depth (m below water table) 3.300E+00 1.000E+01 --- DWIBWT R014 Model: Nondispersion (ND) or Mass-Balance (MB) ND ND --- MODEL R014 Well pumping rate (m**3/yr) 2.250E+03 2.500E+02 --- UW R015 Number of unsaturated zone strata 1 1 --- NS R015 Unsat. zone 1, thickness (m) 2.600E+00 4.000E+00 --- H(1)

R015 Unsat. zone 1, soil density (g/cm**3) 1.800E+00 1.500E+00 --- DENSUZ(1)

R015 Unsat. zone 1, total porosity 3.500E-01 4.000E-01 --- TPUZ(1)

R015 Unsat. zone 1, effective porosity 2.900E-01 2.000E-01 --- EPUZ(1)

R015 Unsat. zone 1, field capacity 6.600E-02 2.000E-01 --- FCUZ(1)

R015 Unsat. zone 1, soil-specific b parameter 9.700E-01 5.300E+00 --- BUZ(1)

R015 Unsat. zone 1, hydraulic conductivity (m/yr) 2.880E+03 1.000E+01 --- HCUZ(1)

R016 Distribution coefficients for Co-60 R016 Contaminated zone (cm**3/g) 1.161E+03 1.000E+03 --- DCNUCC( 1)

R016 Unsaturated zone 1 (cm**3/g) 1.161E+03 1.000E+03 --- DCNUCU( 1,1)

R016 Saturated zone (cm**3/g) 1.161E+03 1.000E+03 --- DCNUCS( 1)

R016 Leach rate (/yr) 0.000E+00 0.000E+00 1.532E-04 ALEACH( 1)

R016 Solubility constant 0.000E+00 0.000E+00 not used SOLUBK( 1)

R016 Distribution coefficients for Cs-134 R016 Contaminated zone (cm**3/g) 6.150E+02 4.600E+03 --- DCNUCC( 2)

R016 Unsaturated zone 1 (cm**3/g) 6.150E+02 4.600E+03 --- DCNUCU( 2,1)

R016 Saturated zone (cm**3/g) 6.150E+02 4.600E+03 --- DCNUCS( 2)

R016 Leach rate (/yr) 0.000E+00 0.000E+00 2.893E-04 ALEACH( 2)

R016 Solubility constant 0.000E+00 0.000E+00 not used SOLUBK( 2)

R016 Distribution coefficients for Cs-137 R016 Contaminated zone (cm**3/g) 6.150E+02 4.600E+03 --- DCNUCC( 3)

R016 Unsaturated zone 1 (cm**3/g) 6.150E+02 4.600E+03 --- DCNUCU( 3,1)

R016 Saturated zone (cm**3/g) 6.150E+02 4.600E+03 --- DCNUCS( 3)

R016 Leach rate (/yr) 0.000E+00 0.000E+00 2.893E-04 ALEACH( 3)

R016 Solubility constant 0.000E+00 0.000E+00 not used SOLUBK( 3)

R016 Distribution coefficients for Ni-63 R016 Contaminated zone (cm**3/g) 6.200E+01 1.000E+03 --- DCNUCC( 4)

R016 Unsaturated zone 1 (cm**3/g) 6.200E+01 1.000E+03 --- DCNUCU( 4,1)

R016 Saturated zone (cm**3/g) 6.200E+01 1.000E+03 --- DCNUCS( 4)

R016 Leach rate (/yr) 0.000E+00 0.000E+00 2.868E-03 ALEACH( 4)

R016 Solubility constant 0.000E+00 0.000E+00 not used SOLUBK( 4)

R016 Distribution coefficients for Sr-90 R016 Contaminated zone (cm**3/g) 2.300E+00 3.000E+01 --- DCNUCC( 5)

R016 Unsaturated zone 1 (cm**3/g) 2.300E+00 3.000E+01 --- DCNUCU( 5,1)

R016 Saturated zone (cm**3/g) 2.300E+00 3.000E+01 --- DCNUCS( 5)

R016 Leach rate (/yr) 0.000E+00 0.000E+00 7.614E-02 ALEACH( 5)

R016 Solubility constant 0.000E+00 0.000E+00 not used SOLUBK( 5)

RESRAD, Version 7.0 T1/2 Limit = 30 days 12/06/2014 16:11 Page 6 Summary : Zion Subsurface Soil 3,000 m^2 120614 File : C:\\RESRAD_FAMILY\\RESRAD\\7.0\\USERFILES\\ZION SUBSURFACE SOIL DCGL.RAD Site-Specific Parameter Summary (continued)

User Used by RESRAD Parameter Menu Parameter Input Default (If different from user input) Name HHHHH R017 Inhalation rate (m**3/yr) 8.400E+03 8.400E+03 --- INHALR R017 Mass loading for inhalation (g/m**3) 2.350E-05 1.000E-04 --- MLINH R017 Exposure duration 3.000E+01 3.000E+01 --- ED R017 Shielding factor, inhalation 5.500E-01 4.000E-01 --- SHF3 R017 Shielding factor, external gamma 4.000E-01 7.000E-01 --- SHF1 R017 Fraction of time spent indoors 6.490E-01 5.000E-01 --- FIND R017 Fraction of time spent outdoors (on site) 1.240E-01 2.500E-01 --- FOTD R017 Shape factor flag, external gamma 1.000E+00 1.000E+00 >0 shows circular AREA. FS R017 Radii of shape factor array (used if FS = -1):

R017 Outer annular radius (m), ring 1: not used 5.000E+01 --- RAD_SHAPE( 1)

R017 Outer annular radius (m), ring 2: not used 7.071E+01 --- RAD_SHAPE( 2)

R017 Outer annular radius (m), ring 3: not used 0.000E+00 --- RAD_SHAPE( 3)

R017 Outer annular radius (m), ring 4: not used 0.000E+00 --- RAD_SHAPE( 4)

R017 Outer annular radius (m), ring 5: not used 0.000E+00 --- RAD_SHAPE( 5)

R017 Outer annular radius (m), ring 6: not used 0.000E+00 --- RAD_SHAPE( 6)

R017 Outer annular radius (m), ring 7: not used 0.000E+00 --- RAD_SHAPE( 7)

R017 Outer annular radius (m), ring 8: not used 0.000E+00 --- RAD_SHAPE( 8)

R017 Outer annular radius (m), ring 9: not used 0.000E+00 --- RAD_SHAPE( 9)

R017 Outer annular radius (m), ring 10: not used 0.000E+00 --- RAD_SHAPE(10)

R017 Outer annular radius (m), ring 11: not used 0.000E+00 --- RAD_SHAPE(11)

R017 Outer annular radius (m), ring 12: not used 0.000E+00 --- RAD_SHAPE(12)

R017 Fractions of annular areas within AREA:

R017 Ring 1 not used 1.000E+00 --- FRACA( 1)

R017 Ring 2 not used 2.732E-01 --- FRACA( 2)

R017 Ring 3 not used 0.000E+00 --- FRACA( 3)

R017 Ring 4 not used 0.000E+00 --- FRACA( 4)

R017 Ring 5 not used 0.000E+00 --- FRACA( 5)

R017 Ring 6 not used 0.000E+00 --- FRACA( 6)

R017 Ring 7 not used 0.000E+00 --- FRACA( 7)

R017 Ring 8 not used 0.000E+00 --- FRACA( 8)

R017 Ring 9 not used 0.000E+00 --- FRACA( 9)

R017 Ring 10 not used 0.000E+00 --- FRACA(10)

R017 Ring 11 not used 0.000E+00 --- FRACA(11)

R017 Ring 12 not used 0.000E+00 --- FRACA(12)

R018 Fruits, vegetables and grain consumption (kg/yr) 1.120E+02 1.600E+02 --- DIET(1)

R018 Leafy vegetable consumption (kg/yr) 2.140E+01 1.400E+01 --- DIET(2)

R018 Milk consumption (L/yr) 2.330E+02 9.200E+01 --- DIET(3)

R018 Meat and poultry consumption (kg/yr) 6.510E+01 6.300E+01 --- DIET(4)

R018 Fish consumption (kg/yr) not used 5.400E+00 --- DIET(5)

R018 Other seafood consumption (kg/yr) not used 9.000E-01 --- DIET(6)

R018 Soil ingestion rate (g/yr) 1.830E+01 3.650E+01 --- SOIL R018 Drinking water intake (L/yr) 4.780E+02 5.100E+02 --- DWI R018 Contamination fraction of drinking water 1.000E+00 1.000E+00 --- FDW R018 Contamination fraction of household water not used 1.000E+00 --- FHHW R018 Contamination fraction of livestock water 1.000E+00 1.000E+00 --- FLW R018 Contamination fraction of irrigation water 1.000E+00 1.000E+00 --- FIRW R018 Contamination fraction of aquatic food not used 5.000E-01 --- FR9 R018 Contamination fraction of plant food -1 -1 0.500E+00 FPLANT

RESRAD, Version 7.0 T1/2 Limit = 30 days 12/06/2014 16:11 Page 7 Summary : Zion Subsurface Soil 3,000 m^2 120614 File : C:\\RESRAD_FAMILY\\RESRAD\\7.0\\USERFILES\\ZION SUBSURFACE SOIL DCGL.RAD Site-Specific Parameter Summary (continued)

User Used by RESRAD Parameter Menu Parameter Input Default (If different from user input) Name HHHHH R018 Contamination fraction of meat -1 -1 0.150E+00 FMEAT R018 Contamination fraction of milk -1 -1 0.150E+00 FMILK R019 Livestock fodder intake for meat (kg/day) 2.830E+01 6.800E+01 --- LFI5 R019 Livestock fodder intake for milk (kg/day) 6.520E+01 5.500E+01 --- LFI6 R019 Livestock water intake for meat (L/day) 5.060E+01 5.000E+01 --- LWI5 R019 Livestock water intake for milk (L/day) 6.000E+01 1.600E+02 --- LWI6 R019 Livestock soil intake (kg/day) 5.000E-01 5.000E-01 --- LSI R019 Mass loading for foliar deposition (g/m**3) 4.000E-04 1.000E-04 --- MLFD R019 Depth of soil mixing layer (m) 2.300E-01 1.500E-01 --- DM R019 Depth of roots (m) 1.220E+00 9.000E-01 --- DROOT R019 Drinking water fraction from ground water 1.000E+00 1.000E+00 --- FGWDW R019 Household water fraction from ground water not used 1.000E+00 --- FGWHH R019 Livestock water fraction from ground water 1.000E+00 1.000E+00 --- FGWLW R019 Irrigation fraction from ground water 1.000E+00 1.000E+00 --- FGWIR R19B Wet weight crop yield for Non-Leafy (kg/m**2) 1.750E+00 7.000E-01 --- YV(1)

R19B Wet weight crop yield for Leafy (kg/m**2) 2.900E+00 1.500E+00 --- YV(2)

R19B Wet weight crop yield for Fodder (kg/m**2) 1.900E+00 1.100E+00 --- YV(3)

R19B Growing Season for Non-Leafy (years) 2.460E-01 1.700E-01 --- TE(1)

R19B Growing Season for Leafy (years) 1.230E-01 2.500E-01 --- TE(2)

R19B Growing Season for Fodder (years) 8.200E-02 8.000E-02 --- TE(3)

R19B Translocation Factor for Non-Leafy 1.000E-01 1.000E-01 --- TIV(1)

R19B Translocation Factor for Leafy 1.000E+00 1.000E+00 --- TIV(2)

R19B Translocation Factor for Fodder 1.000E+00 1.000E+00 --- TIV(3)

R19B Dry Foliar Interception Fraction for Non-Leafy 3.500E-01 2.500E-01 --- RDRY(1)

R19B Dry Foliar Interception Fraction for Leafy 3.500E-01 2.500E-01 --- RDRY(2)

R19B Dry Foliar Interception Fraction for Fodder 3.500E-01 2.500E-01 --- RDRY(3)

R19B Wet Foliar Interception Fraction for Non-Leafy 3.500E-01 2.500E-01 --- RWET(1)

R19B Wet Foliar Interception Fraction for Leafy 5.800E-01 2.500E-01 --- RWET(2)

R19B Wet Foliar Interception Fraction for Fodder 3.500E-01 2.500E-01 --- RWET(3)

R19B Weathering Removal Constant for Vegetation 3.300E+01 2.000E+01 --- WLAM C14 C-12 concentration in water (g/cm**3) not used 2.000E-05 --- C12WTR C14 C-12 concentration in contaminated soil (g/g) not used 3.000E-02 --- C12CZ C14 Fraction of vegetation carbon from soil not used 2.000E-02 --- CSOIL C14 Fraction of vegetation carbon from air not used 9.800E-01 --- CAIR C14 C-14 evasion layer thickness in soil (m) not used 3.000E-01 --- DMC C14 C-14 evasion flux rate from soil (1/sec) not used 7.000E-07 --- EVSN C14 C-12 evasion flux rate from soil (1/sec) not used 1.000E-10 --- REVSN C14 Fraction of grain in beef cattle feed not used 8.000E-01 --- AVFG4 C14 Fraction of grain in milk cow feed not used 2.000E-01 --- AVFG5 STOR Storage times of contaminated foodstuffs (days):

STOR Fruits, non-leafy vegetables, and grain 1.400E+01 1.400E+01 --- STOR_T(1)

STOR Leafy vegetables 1.000E+00 1.000E+00 --- STOR_T(2)

STOR Milk 1.000E+00 1.000E+00 --- STOR_T(3)

STOR Meat and poultry 1.000E+00 2.000E+01 --- STOR_T(4)

STOR Fish 7.000E+00 7.000E+00 --- STOR_T(5)

STOR Crustacea and mollusks 7.000E+00 7.000E+00 --- STOR_T(6)

RESRAD, Version 7.0 T1/2 Limit = 30 days 12/06/2014 16:11 Page 8 Summary : Zion Subsurface Soil 3,000 m^2 120614 File : C:\\RESRAD_FAMILY\\RESRAD\\7.0\\USERFILES\\ZION SUBSURFACE SOIL DCGL.RAD Site-Specific Parameter Summary (continued)

User Used by RESRAD Parameter Menu Parameter Input Default (If different from user input) Name HHHHH STOR Well water 1.000E+00 1.000E+00 --- STOR_T(7)

STOR Surface water 1.000E+00 1.000E+00 --- STOR_T(8)

STOR Livestock fodder 4.500E+01 4.500E+01 --- STOR_T(9)

R021 Thickness of building foundation (m) not used 1.500E-01 --- FLOOR1 R021 Bulk density of building foundation (g/cm**3) not used 2.400E+00 --- DENSFL R021 Total porosity of the cover material not used 4.000E-01 --- TPCV R021 Total porosity of the building foundation not used 1.000E-01 --- TPFL R021 Volumetric water content of the cover material not used 5.000E-02 --- PH2OCV R021 Volumetric water content of the foundation not used 3.000E-02 --- PH2OFL R021 Diffusion coefficient for radon gas (m/sec):

R021 in cover material not used 2.000E-06 --- DIFCV R021 in foundation material not used 3.000E-07 --- DIFFL R021 in contaminated zone soil not used 2.000E-06 --- DIFCZ R021 Radon vertical dimension of mixing (m) not used 2.000E+00 --- HMIX R021 Average building air exchange rate (1/hr) not used 5.000E-01 --- REXG R021 Height of the building (room) (m) not used 2.500E+00 --- HRM R021 Building interior area factor not used 0.000E+00 --- FAI R021 Building depth below ground surface (m) not used -1.000E+00 --- DMFL R021 Emanating power of Rn-222 gas not used 2.500E-01 --- EMANA(1)

R021 Emanating power of Rn-220 gas not used 1.500E-01 --- EMANA(2)

TITL Number of graphical time points 512 --- --- NPTS TITL Maximum number of integration points for dose 17 --- --- LYMAX TITL Maximum number of integration points for risk 17 --- --- KYMAX

Summary of Pathway Selections Pathway User Selection H

1 -- external gamma active 2 -- inhalation (w/o radon) active 3 -- plant ingestion active 4 -- meat ingestion active 5 -- milk ingestion active 6 -- aquatic foods suppressed 7 -- drinking water active 8 -- soil ingestion active 9 -- radon suppressed Find peak pathway doses active

RESRAD, Version 7.0 T1/2 Limit = 30 days 12/06/2014 16:11 Page 9 Summary : Zion Subsurface Soil 3,000 m^2 120614 File : C:\\RESRAD_FAMILY\\RESRAD\\7.0\\USERFILES\\ZION SUBSURFACE SOIL DCGL.RAD Contaminated Zone Dimensions Initial Soil Concentrations, pCi/g Area: 3000.00 square meters Co-60 1.000E+00 Thickness: 1.00 meters Cs-134 1.000E+00 Cover Depth: 0.00 meters Cs-137 1.000E+00 Ni-63 1.000E+00 Sr-90 1.000E+00 Total Dose TDOSE(t), mrem/yr Basic Radiation Dose Limit = 2.500E+01 mrem/yr Total Mixture Sum M(t) = Fraction of Basic Dose Limit Received at Time (t) t (years): 0.000E+00 1.000E+00 3.000E+00 1.000E+01 3.000E+01 1.000E+02 3.000E+02 1.000E+03 TDOSE(t): 1.579E+01 1.361E+01 1.036E+01 4.782E+00 1.822E+00 1.615E-01 1.500E-03 7.268E-07 M(t): 6.317E-01 5.444E-01 4.145E-01 1.913E-01 7.287E-02 6.462E-03 6.001E-05 2.907E-08 Maximum TDOSE(t): 1.579E+01 mrem/yr at t = 0.000E+00 years

RESRAD, Version 7.0 T1/2 Limit = 30 days 12/06/2014 16:11 Page 10 Summary : Zion Subsurface Soil 3,000 m^2 120614 File : C:\\RESRAD_FAMILY\\RESRAD\\7.0\\USERFILES\\ZION SUBSURFACE SOIL DCGL.RAD Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)

As mrem/yr and Fraction of Total Dose At t = 0.000E+00 years Water Independent Pathways (Inhalation excludes radon)

Ground Inhalation Radon Plant Meat Milk Soil Radio-Nuclide mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract.

Co-60 5.328E+00 0.3374 1.427E-06 0.0000 0.000E+00 0.0000 2.066E-01 0.0131 5.678E-02 0.0036 1.500E-02 0.0009 3.565E-04 0.0000 Cs-134 2.799E+00 0.1773 2.728E-07 0.0000 0.000E+00 0.0000 2.653E-01 0.0168 9.123E-02 0.0058 1.422E-01 0.0090 8.807E-04 0.0001 Cs-137 1.171E+00 0.0742 2.192E-07 0.0000 0.000E+00 0.0000 2.106E-01 0.0133 7.242E-02 0.0046 1.129E-01 0.0071 6.991E-04 0.0000 Ni-63 0.000E+00 0.0000 4.352E-08 0.0000 0.000E+00 0.0000 2.886E-03 0.0002 7.383E-05 0.0000 3.478E-03 0.0002 8.122E-06 0.0000 Sr-90 8.203E-03 0.0005 8.656E-06 0.0000 0.000E+00 0.0000 4.697E+00 0.2974 1.624E-01 0.0103 4.430E-01 0.0281 2.057E-03 0.0001 Total 9.307E+00 0.5893 1.062E-05 0.0000 0.000E+00 0.0000 5.383E+00 0.3408 3.829E-01 0.0242 7.165E-01 0.0454 4.001E-03 0.0003 Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)

As mrem/yr and Fraction of Total Dose At t = 0.000E+00 years Water Dependent Pathways Water Fish Radon Plant Meat Milk All Pathways*

Radio-Nuclide mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract.

Co-60 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 5.607E+00 0.3550 Cs-134 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 3.299E+00 0.2089 Cs-137 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.568E+00 0.0993 Ni-63 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 6.446E-03 0.0004 Sr-90 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 5.313E+00 0.3364 Total 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.579E+01 1.0000

  • Sum of all water independent and dependent pathways.

RESRAD, Version 7.0 T1/2 Limit = 30 days 12/06/2014 16:11 Page 11 Summary : Zion Subsurface Soil 3,000 m^2 120614 File : C:\\RESRAD_FAMILY\\RESRAD\\7.0\\USERFILES\\ZION SUBSURFACE SOIL DCGL.RAD Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)

As mrem/yr and Fraction of Total Dose At t = 1.000E+00 years Water Independent Pathways (Inhalation excludes radon)

Ground Inhalation Radon Plant Meat Milk Soil Radio-Nuclide mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract.

Co-60 4.671E+00 0.3432 1.251E-06 0.0000 0.000E+00 0.0000 1.808E-01 0.0133 4.971E-02 0.0037 1.313E-02 0.0010 3.126E-04 0.0000 Cs-134 2.001E+00 0.1470 1.950E-07 0.0000 0.000E+00 0.0000 1.893E-01 0.0139 6.512E-02 0.0048 1.015E-01 0.0075 6.294E-04 0.0000 Cs-137 1.144E+00 0.0841 2.142E-07 0.0000 0.000E+00 0.0000 2.055E-01 0.0151 7.067E-02 0.0052 1.101E-01 0.0081 6.831E-04 0.0001 Ni-63 0.000E+00 0.0000 4.310E-08 0.0000 0.000E+00 0.0000 2.854E-03 0.0002 7.303E-05 0.0000 3.439E-03 0.0003 8.043E-06 0.0000 Sr-90 7.421E-03 0.0005 7.831E-06 0.0000 0.000E+00 0.0000 4.244E+00 0.3118 1.468E-01 0.0108 4.005E-01 0.0294 1.861E-03 0.0001 Total 7.823E+00 0.5748 9.534E-06 0.0000 0.000E+00 0.0000 4.822E+00 0.3543 3.324E-01 0.0244 6.287E-01 0.0462 3.494E-03 0.0003 Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)

As mrem/yr and Fraction of Total Dose At t = 1.000E+00 years Water Dependent Pathways Water Fish Radon Plant Meat Milk All Pathways*

Radio-Nuclide mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract.

Co-60 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 4.915E+00 0.3611 Cs-134 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 2.357E+00 0.1732 Cs-137 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.531E+00 0.1125 Ni-63 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 6.374E-03 0.0005 Sr-90 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 4.801E+00 0.3527 Total 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.361E+01 1.0000

  • Sum of all water independent and dependent pathways.

RESRAD, Version 7.0 T1/2 Limit = 30 days 12/06/2014 16:11 Page 12 Summary : Zion Subsurface Soil 3,000 m^2 120614 File : C:\\RESRAD_FAMILY\\RESRAD\\7.0\\USERFILES\\ZION SUBSURFACE SOIL DCGL.RAD Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)

As mrem/yr and Fraction of Total Dose At t = 3.000E+00 years Water Independent Pathways (Inhalation excludes radon)

Ground Inhalation Radon Plant Meat Milk Soil Radio-Nuclide mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract.

Co-60 3.590E+00 0.3464 9.612E-07 0.0000 0.000E+00 0.0000 1.385E-01 0.0134 3.811E-02 0.0037 1.006E-02 0.0010 2.402E-04 0.0000 Cs-134 1.022E+00 0.0986 9.957E-08 0.0000 0.000E+00 0.0000 9.640E-02 0.0093 3.318E-02 0.0032 5.168E-02 0.0050 3.214E-04 0.0000 Cs-137 1.092E+00 0.1054 2.045E-07 0.0000 0.000E+00 0.0000 1.955E-01 0.0189 6.730E-02 0.0065 1.048E-01 0.0101 6.520E-04 0.0001 Ni-63 0.000E+00 0.0000 4.226E-08 0.0000 0.000E+00 0.0000 2.790E-03 0.0003 7.144E-05 0.0000 3.364E-03 0.0003 7.887E-06 0.0000 Sr-90 6.073E-03 0.0006 6.409E-06 0.0000 0.000E+00 0.0000 3.463E+00 0.3341 1.198E-01 0.0116 3.268E-01 0.0315 1.523E-03 0.0001 Total 5.710E+00 0.5509 7.716E-06 0.0000 0.000E+00 0.0000 3.896E+00 0.3759 2.585E-01 0.0249 4.967E-01 0.0479 2.744E-03 0.0003 Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)

As mrem/yr and Fraction of Total Dose At t = 3.000E+00 years Water Dependent Pathways Water Fish Radon Plant Meat Milk All Pathways*

Radio-Nuclide mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract.

Co-60 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 3.777E+00 0.3644 Cs-134 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.203E+00 0.1161 Cs-137 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.460E+00 0.1409 Ni-63 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 6.233E-03 0.0006 Sr-90 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 3.917E+00 0.3779 Total 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.036E+01 1.0000

  • Sum of all water independent and dependent pathways.

RESRAD, Version 7.0 T1/2 Limit = 30 days 12/06/2014 16:11 Page 13 Summary : Zion Subsurface Soil 3,000 m^2 120614 File : C:\\RESRAD_FAMILY\\RESRAD\\7.0\\USERFILES\\ZION SUBSURFACE SOIL DCGL.RAD Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)

As mrem/yr and Fraction of Total Dose At t = 1.000E+01 years Water Independent Pathways (Inhalation excludes radon)

Ground Inhalation Radon Plant Meat Milk Soil Radio-Nuclide mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract.

Co-60 1.428E+00 0.2987 3.825E-07 0.0000 0.000E+00 0.0000 5.454E-02 0.0114 1.502E-02 0.0031 3.964E-03 0.0008 9.558E-05 0.0000 Cs-134 9.725E-02 0.0203 9.478E-09 0.0000 0.000E+00 0.0000 9.079E-03 0.0019 3.132E-03 0.0007 4.873E-03 0.0010 3.059E-05 0.0000 Cs-137 9.280E-01 0.1941 1.737E-07 0.0000 0.000E+00 0.0000 1.644E-01 0.0344 5.671E-02 0.0119 8.823E-02 0.0185 5.540E-04 0.0001 Ni-63 0.000E+00 0.0000 3.946E-08 0.0000 0.000E+00 0.0000 2.578E-03 0.0005 6.614E-05 0.0000 3.111E-03 0.0007 7.365E-06 0.0000 Sr-90 3.011E-03 0.0006 3.178E-06 0.0000 0.000E+00 0.0000 1.699E+00 0.3553 5.880E-02 0.0123 1.604E-01 0.0335 7.550E-04 0.0002 Total 2.457E+00 0.5138 3.783E-06 0.0000 0.000E+00 0.0000 1.929E+00 0.4035 1.337E-01 0.0280 2.605E-01 0.0545 1.443E-03 0.0003 Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)

As mrem/yr and Fraction of Total Dose At t = 1.000E+01 years Water Dependent Pathways Water Fish Radon Plant Meat Milk All Pathways*

Radio-Nuclide mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract.

Co-60 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.502E+00 0.3141 Cs-134 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.144E-01 0.0239 Cs-137 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.238E+00 0.2589 Ni-63 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 5.762E-03 0.0012 Sr-90 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.922E+00 0.4019 Total 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 4.782E+00 1.0000

  • Sum of all water independent and dependent pathways.

RESRAD, Version 7.0 T1/2 Limit = 30 days 12/06/2014 16:11 Page 14 Summary : Zion Subsurface Soil 3,000 m^2 120614 File : C:\\RESRAD_FAMILY\\RESRAD\\7.0\\USERFILES\\ZION SUBSURFACE SOIL DCGL.RAD Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)

As mrem/yr and Fraction of Total Dose At t = 3.000E+01 years Water Independent Pathways (Inhalation excludes radon)

Ground Inhalation Radon Plant Meat Milk Soil Radio-Nuclide mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract.

Co-60 1.027E-01 0.0563 2.749E-08 0.0000 0.000E+00 0.0000 3.800E-03 0.0021 1.051E-03 0.0006 2.767E-04 0.0002 6.869E-06 0.0000 Cs-134 1.174E-04 0.0001 1.144E-11 0.0000 0.000E+00 0.0000 1.062E-05 0.0000 3.690E-06 0.0000 5.721E-06 0.0000 3.692E-08 0.0000 Cs-137 5.827E-01 0.3199 1.091E-07 0.0000 0.000E+00 0.0000 1.001E-01 0.0549 3.476E-02 0.0191 5.390E-02 0.0296 3.479E-04 0.0002 Ni-63 0.000E+00 0.0000 3.244E-08 0.0000 0.000E+00 0.0000 2.055E-03 0.0011 5.303E-05 0.0000 2.487E-03 0.0014 6.055E-06 0.0000 Sr-90 4.058E-04 0.0002 4.282E-07 0.0000 0.000E+00 0.0000 2.219E-01 0.1218 7.691E-03 0.0042 2.096E-02 0.0115 1.017E-04 0.0001 Total 6.859E-01 0.3765 5.972E-07 0.0000 0.000E+00 0.0000 3.279E-01 0.1800 4.356E-02 0.0239 7.763E-02 0.0426 4.626E-04 0.0003 Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)

As mrem/yr and Fraction of Total Dose At t = 3.000E+01 years Water Dependent Pathways Water Fish Radon Plant Meat Milk All Pathways*

Radio-Nuclide mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract.

Co-60 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.078E-01 0.0592 Cs-134 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.374E-04 0.0001 Cs-137 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 7.718E-01 0.4237 Ni-63 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 4.601E-03 0.0025 Sr-90 6.324E-01 0.3472 0.000E+00 0.0000 0.000E+00 0.0000 3.051E-02 0.0167 8.039E-03 0.0044 1.532E-02 0.0084 9.374E-01 0.5146 Total 6.324E-01 0.3472 0.000E+00 0.0000 0.000E+00 0.0000 3.051E-02 0.0167 8.039E-03 0.0044 1.532E-02 0.0084 1.822E+00 1.0000

  • Sum of all water independent and dependent pathways.

RESRAD, Version 7.0 T1/2 Limit = 30 days 12/06/2014 16:11 Page 15 Summary : Zion Subsurface Soil 3,000 m^2 120614 File : C:\\RESRAD_FAMILY\\RESRAD\\7.0\\USERFILES\\ZION SUBSURFACE SOIL DCGL.RAD Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)

As mrem/yr and Fraction of Total Dose At t = 1.000E+02 years Water Independent Pathways (Inhalation excludes radon)

Ground Inhalation Radon Plant Meat Milk Soil Radio-Nuclide mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract.

Co-60 1.021E-05 0.0001 2.735E-12 0.0000 0.000E+00 0.0000 3.365E-07 0.0000 9.457E-08 0.0000 2.469E-08 0.0000 6.835E-10 0.0000 Cs-134 7.168E-15 0.0000 6.985E-22 0.0000 0.000E+00 0.0000 5.774E-16 0.0000 2.061E-16 0.0000 3.152E-16 0.0000 2.255E-18 0.0000 Cs-137 1.143E-01 0.7078 2.140E-08 0.0000 0.000E+00 0.0000 1.748E-02 0.1082 6.239E-03 0.0386 9.541E-03 0.0591 6.825E-05 0.0004 Ni-63 0.000E+00 0.0000 1.635E-08 0.0000 0.000E+00 0.0000 9.214E-04 0.0057 2.436E-05 0.0002 1.128E-03 0.0070 3.051E-06 0.0000 Sr-90 3.644E-07 0.0000 3.846E-10 0.0000 0.000E+00 0.0000 1.774E-04 0.0011 6.175E-06 0.0000 1.679E-05 0.0001 9.137E-08 0.0000 Total 1.143E-01 0.7078 3.814E-08 0.0000 0.000E+00 0.0000 1.857E-02 0.1150 6.269E-03 0.0388 1.069E-02 0.0662 7.140E-05 0.0004 Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)

As mrem/yr and Fraction of Total Dose At t = 1.000E+02 years Water Dependent Pathways Water Fish Radon Plant Meat Milk All Pathways*

Radio-Nuclide mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract.

Co-60 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.067E-05 0.0001 Cs-134 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 8.269E-15 0.0000 Cs-137 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.477E-01 0.9141 Ni-63 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 2.077E-03 0.0129 Sr-90 1.067E-02 0.0660 0.000E+00 0.0000 0.000E+00 0.0000 5.197E-04 0.0032 1.389E-04 0.0009 2.673E-04 0.0017 1.180E-02 0.0730 Total 1.067E-02 0.0660 0.000E+00 0.0000 0.000E+00 0.0000 5.197E-04 0.0032 1.389E-04 0.0009 2.673E-04 0.0017 1.615E-01 1.0000

  • Sum of all water independent and dependent pathways.

RESRAD, Version 7.0 T1/2 Limit = 30 days 12/06/2014 16:11 Page 16 Summary : Zion Subsurface Soil 3,000 m^2 120614 File : C:\\RESRAD_FAMILY\\RESRAD\\7.0\\USERFILES\\ZION SUBSURFACE SOIL DCGL.RAD Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)

As mrem/yr and Fraction of Total Dose At t = 3.000E+02 years Water Independent Pathways (Inhalation excludes radon)

Ground Inhalation Radon Plant Meat Milk Soil Radio-Nuclide mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract.

Co-60 3.752E-17 0.0000 1.005E-23 0.0000 0.000E+00 0.0000 7.998E-19 0.0000 2.425E-19 0.0000 6.087E-20 0.0000 2.512E-21 0.0000 Cs-134 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Cs-137 1.090E-03 0.7262 2.040E-10 0.0000 0.000E+00 0.0000 1.077E-04 0.0718 4.362E-05 0.0291 6.279E-05 0.0419 6.505E-07 0.0004 Ni-63 0.000E+00 0.0000 2.306E-09 0.0000 0.000E+00 0.0000 8.407E-05 0.0560 2.485E-06 0.0017 1.090E-04 0.0726 4.304E-07 0.0003 Sr-90 7.192E-16 0.0000 7.589E-19 0.0000 0.000E+00 0.0000 2.264E-13 0.0000 8.059E-15 0.0000 2.164E-14 0.0000 1.803E-16 0.0000 Total 1.090E-03 0.7262 2.510E-09 0.0000 0.000E+00 0.0000 1.918E-04 0.1278 4.610E-05 0.0307 1.718E-04 0.1145 1.081E-06 0.0007 Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)

As mrem/yr and Fraction of Total Dose At t = 3.000E+02 years Water Dependent Pathways Water Fish Radon Plant Meat Milk All Pathways*

Radio-Nuclide mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract.

Co-60 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 3.862E-17 0.0000 Cs-134 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Cs-137 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.304E-03 0.8694 Ni-63 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.960E-04 0.1306 Sr-90 1.412E-11 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 6.879E-13 0.0000 1.838E-13 0.0000 3.538E-13 0.0000 1.560E-11 0.0000 Total 1.412E-11 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 6.879E-13 0.0000 1.838E-13 0.0000 3.538E-13 0.0000 1.500E-03 1.0000

  • Sum of all water independent and dependent pathways.

RESRAD, Version 7.0 T1/2 Limit = 30 days 12/06/2014 16:11 Page 17 Summary : Zion Subsurface Soil 3,000 m^2 120614 File : C:\\RESRAD_FAMILY\\RESRAD\\7.0\\USERFILES\\ZION SUBSURFACE SOIL DCGL.RAD Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)

As mrem/yr and Fraction of Total Dose At t = 1.000E+03 years Water Independent Pathways (Inhalation excludes radon)

Ground Inhalation Radon Plant Meat Milk Soil Radio-Nuclide mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract.

Co-60 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Cs-134 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Cs-137 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Ni-63 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Sr-90 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Total 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)

As mrem/yr and Fraction of Total Dose At t = 1.000E+03 years Water Dependent Pathways Water Fish Radon Plant Meat Milk All Pathways*

Radio-Nuclide mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract.

Co-60 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Cs-134 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Cs-137 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Ni-63 5.422E-07 0.7461 0.000E+00 0.0000 0.000E+00 0.0000 2.188E-08 0.0301 4.360E-09 0.0060 1.583E-07 0.2178 7.268E-07 1.0000 Sr-90 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Total 5.422E-07 0.7461 0.000E+00 0.0000 0.000E+00 0.0000 2.188E-08 0.0301 4.360E-09 0.0060 1.583E-07 0.2178 7.268E-07 1.0000

  • Sum of all water independent and dependent pathways.

RESRAD, Version 7.0 T1/2 Limit = 30 days 12/06/2014 16:11 Page 18 Summary : Zion Subsurface Soil 3,000 m^2 120614 File : C:\\RESRAD_FAMILY\\RESRAD\\7.0\\USERFILES\\ZION SUBSURFACE SOIL DCGL.RAD Dose/Source Ratios Summed Over All Pathways Parent and Progeny Principal Radionuclide Contributions Indicated Parent Product Thread DSR(j,t) At Time in Years (mrem/yr)/(pCi/g)

(i) (j) Fraction 0.000E+00 1.000E+00 3.000E+00 1.000E+01 3.000E+01 1.000E+02 3.000E+02 1.000E+03 Co-60 Co-60 1.000E+00 5.607E+00 4.915E+00 3.777E+00 1.502E+00 1.078E-01 1.067E-05 3.862E-17 0.000E+00 Cs-134 Cs-134 1.000E+00 3.299E+00 2.357E+00 1.203E+00 1.144E-01 1.374E-04 8.269E-15 4.764E-44 0.000E+00 Cs-137+D Cs-137+D 1.000E+00 1.568E+00 1.531E+00 1.460E+00 1.238E+00 7.718E-01 1.477E-01 1.304E-03 0.000E+00 Ni-63 Ni-63 1.000E+00 6.446E-03 6.374E-03 6.233E-03 5.762E-03 4.601E-03 2.077E-03 1.960E-04 7.268E-07 Sr-90+D Sr-90+D 1.000E+00 5.313E+00 4.801E+00 3.917E+00 1.922E+00 9.374E-01 1.180E-02 1.560E-11 0.000E+00 The DSR includes contributions from associated (half-life 30 days) daughters.

Single Radionuclide Soil Guidelines G(i,t) in pCi/g Basic Radiation Dose Limit = 2.500E+01 mrem/yr Nuclide (i) t= 0.000E+00 1.000E+00 3.000E+00 1.000E+01 3.000E+01 1.000E+02 3.000E+02 1.000E+03 Co-60 4.459E+00 5.087E+00 6.620E+00 1.664E+01 2.319E+02 2.343E+06 *1.113E+15 *1.113E+15 Cs-134 7.578E+00 1.061E+01 2.078E+01 2.186E+02 1.819E+05 *1.283E+15 *1.283E+15 *1.283E+15 Cs-137 1.595E+01 1.633E+01 1.712E+01 2.019E+01 3.239E+01 1.693E+02 1.917E+04 *8.593E+13 Ni-63 3.878E+03 3.922E+03 4.011E+03 4.339E+03 5.434E+03 1.204E+04 1.276E+05 3.440E+07 Sr-90 4.705E+00 5.208E+00 6.383E+00 1.301E+01 2.667E+01 2.119E+03 1.602E+12 *1.366E+14

  • At specific activity limit Summed Dose/Source Ratios DSR(i,t) in (mrem/yr)/(pCi/g) and Single Radionuclide Soil Guidelines G(i,t) in pCi/g at tmin = time of minimum single radionuclide soil guideline and at tmax = time of maximum total dose = 0.000E+00 years Nuclide Initial tmin DSR(i,tmin) G(i,tmin) DSR(i,tmax) G(i,tmax)

(i) (pCi/g) (years) (pCi/g) (pCi/g)

Co-60 1.000E+00 0.000E+00 5.607E+00 4.459E+00 5.607E+00 4.459E+00 Cs-134 1.000E+00 0.000E+00 3.299E+00 7.578E+00 3.299E+00 7.578E+00 Cs-137 1.000E+00 0.000E+00 1.568E+00 1.595E+01 1.568E+00 1.595E+01 Ni-63 1.000E+00 0.000E+00 6.446E-03 3.878E+03 6.446E-03 3.878E+03 Sr-90 1.000E+00 0.000E+00 5.313E+00 4.705E+00 5.313E+00 4.705E+00

RESRAD, Version 7.0 T1/2 Limit = 30 days 12/06/2014 16:11 Page 19 Summary : Zion Subsurface Soil 3,000 m^2 120614 File : C:\\RESRAD_FAMILY\\RESRAD\\7.0\\USERFILES\\ZION SUBSURFACE SOIL DCGL.RAD Individual Nuclide Dose Summed Over All Pathways Parent Nuclide and Branch Fraction Indicated Nuclide Parent THF(i) DOSE(j,t), mrem/yr (j) (i) t= 0.000E+00 1.000E+00 3.000E+00 1.000E+01 3.000E+01 1.000E+02 3.000E+02 1.000E+03 Co-60 Co-60 1.000E+00 5.607E+00 4.915E+00 3.777E+00 1.502E+00 1.078E-01 1.067E-05 3.862E-17 0.000E+00 Cs-134 Cs-134 1.000E+00 3.299E+00 2.357E+00 1.203E+00 1.144E-01 1.374E-04 8.269E-15 0.000E+00 0.000E+00 Cs-137 Cs-137 1.000E+00 1.568E+00 1.531E+00 1.460E+00 1.238E+00 7.718E-01 1.477E-01 1.304E-03 0.000E+00 Ni-63 Ni-63 1.000E+00 6.446E-03 6.374E-03 6.233E-03 5.762E-03 4.601E-03 2.077E-03 1.960E-04 7.268E-07 Sr-90 Sr-90 1.000E+00 5.313E+00 4.801E+00 3.917E+00 1.922E+00 9.374E-01 1.180E-02 1.560E-11 0.000E+00 THF(i) is the thread fraction of the parent nuclide.

Individual Nuclide Soil Concentration Parent Nuclide and Branch Fraction Indicated Nuclide Parent THF(i) S(j,t), pCi/g (j) (i) t= 0.000E+00 1.000E+00 3.000E+00 1.000E+01 3.000E+01 1.000E+02 3.000E+02 1.000E+03 Co-60 Co-60 1.000E+00 1.000E+00 8.766E-01 6.737E-01 2.681E-01 1.927E-02 1.917E-06 7.044E-18 0.000E+00 Cs-134 Cs-134 1.000E+00 1.000E+00 7.146E-01 3.650E-01 3.474E-02 4.193E-05 2.560E-15 1.682E-44 0.000E+00 Cs-137 Cs-137 1.000E+00 1.000E+00 9.770E-01 9.326E-01 7.924E-01 4.976E-01 9.763E-02 9.304E-04 7.864E-11 Ni-63 Ni-63 1.000E+00 1.000E+00 9.903E-01 9.710E-01 9.067E-01 7.454E-01 3.756E-01 5.299E-02 5.587E-05 Sr-90 Sr-90 1.000E+00 1.000E+00 9.046E-01 7.403E-01 3.671E-01 4.946E-02 4.442E-05 8.767E-14 2.943E-44 THF(i) is the thread fraction of the parent nuclide.

RESCALC.EXE execution time = 1.79 seconds