ML17129A386

From kanterella
Jump to navigation Jump to search
C1 to Aux
ML17129A386
Person / Time
Site: Zion  File:ZionSolutions icon.png
Issue date: 03/08/2016
From:
ZionSolutions
To:
Office of Nuclear Reactor Regulation
Shared Package
ML17129A311 List: ... further results
References
ZS-2016-0022
Download: ML17129A386 (1)


Text

C1 to Aux Unit 1 Sleeve Sleeve Area Sleeve Insul Azimuth Area Pipe Area Area Pipe Area open to Size Pipe Size Thickness Dwg B-210 Degrees - Below Below Below Below 2 2 2 2 Group Elevation flow (in2) Penetration No. Unit 1 DWG Unit 2 DWG Line Ident No. Pen Type From Building To Building End Sate inches inches in Length in minutes 588' in 588' in 579' in 579' in Remarks C 561.25 452.3893 B-278, M-7, B-223, M-170 Unit 1 Containment Auxiliary Building Open Sleeve 24 20 600 135 452.39 314.16 452.39 314.16 B-278 Sections A-A and B-B C 561.25 452.3893 B-278, M-7, B-223, M-170 Unit 1 Containment Auxiliary Building Open Sleeve 24 20 600 135 452.39 314.16 452.39 314.16 B-278 Sections A-A and B-B C 561.25 452.3893 B-278, M-7, B-223, M-170 Unit 1 Containment Auxiliary Building Open Sleeve 24 20 600 135 452.39 314.16 452.39 314.16 B-278 Sections A-A and B-B C 561.25 452.3893 B-278, M-7, B-223, M-170 Unit 1 Containment Auxiliary Building Open Sleeve 24 20 600 135 452.39 314.16 452.39 314.16 B-279 Sections A-A and B-B C 561.25 452.3893 B-278, M-7, B-223, M-170 Unit 1 Containment Auxiliary Building Open Sleeve 24 20 600 135 452.39 314.16 452.39 314.16 B-279 Sections A-A and B-B C 577.5 78.53982 P-1 M-281 M-661 1-FP-037-4" 5 Unit 1 Containment Auxiliary Building Open Sleeve 10 4 42 107 78.54 12.57 78.54 12.57 M-282 Detail Section B-B C 577.5 28.27433 P-3 M-281 M-661 Unit 1 Containment Auxiliary Building Open Sleeve 6 42 98-16 28.27 28.27 0.00 M-282 Detail Section B-B C 577.5 50.26548 P-4 M-281 M-661 1-S1-090-3" 4 Unit 1 Containment Auxiliary Building Open Sleeve 8 3 42 94 50.27 7.07 50.27 7.07 M-282 Detail Section B-B C 577.5 28.27433 P-42 M-281 M-661 1-WO-95-1 1/2" 5 Unit 1 Containment Auxiliary Building Open Sleeve 6 1.50 42 104-45 28.27 1.77 28.27 1.77 M-282 Detail Section B-B C 577.5 153.938 P-68 M-281 M-661 1-FW-018-3" 4 Unit 1 Containment Auxiliary Building Open Sleeve 14 3 42 100-45' 153.94 7.07 153.94 7.07 M-282 Detail Section B-B C 577.5 153.938 P-69 M-281 M-661 1-FW-015-3" 4 Unit 1 Containment Auxiliary Building Open Sleeve 14 3 42 109-15' 153.94 7.07 153.94 7.07 M-282 Detail Section B-B C 577.5 153.938 P-70 M-281 M-661 1-DT-032-3" 3 Unit 1 Containment Auxiliary Building Open Sleeve 14 3 42 102-45' 153.94 7.07 153.94 7.07 M-282 Detail Section B-B C 577.5 50.26548 P-103 M-282 M-662 Unit 1 Containment Auxiliary Building Open Sleeve 8 42 98-30' 50.27 0.00 50.27 0.00 M-282 Detail Section B-B C 578.54 452.3893 P-49 M-281 M-661 Unit 1 Containment Auxiliary Building Open Sleeve 24 78 90 452.39 452.39 0.00 C 580.083 615.7522 P-22 M-281 M-661 1-RH-006-12" 4B Unit 1 Containment Auxiliary Building Open Sleeve 28 12 3 42 98-30 615.75 113.10 M-282 Detail Section B-B C 580.083 50.26548 P-43 M-281 M-661 1-DT-036-3" 3 Unit 1 Containment Auxiliary Building Open Sleeve 8 3 42 107 50.27 7.07 M-282 Detail Section B-B C 580.083 78.53982 P-50 M-281 M-661 Unit 1 Containment Auxiliary Building Open Sleeve 10 42 96-15' 78.54 M-282 Detail Section B-B C 580.083 50.26548 P-56 M-281 M-661 1-VF-132-2" 5 Unit 1 Containment Auxiliary Building Open Sleeve 8 2 42 100-45' 50.27 3.14 M-282 Detail Section B-B C 580.083 153.938 P-66 M-281 M-661 1-VC-033,043, 052E, 085-2"6 Unit 1 Containment Auxiliary Building Open Sleeve 14 8 42 102-45' 153.94 50.27 M-282 Detail Section B-B C 580.083 50.26548 P-81 M-281 M-661 1-VN-008-2" 5 Unit 1 Containment Auxiliary Building Open Sleeve 8 2 42 109-15' 50.27 3.14 M-282 Detail Section B-B C 580.083 452.3893 P-104 M-282 M-662 1-MS-018-6" 2 Unit 1 Containment Auxiliary Building Open Sleeve 24 6 42 94 452.39 28.27 M-282 Detail Section B-B C 580.083 254.469 P-105 M-282 M-662 1-SI-011-10" 3 Unit 1 Containment Auxiliary Building Open Sleeve 18 10 42 104-45 254.47 78.54 M-282 Detail Section B-B C 584.25 615.7522 P-17 M-281 M-661 1-RH-015-14" 1A Unit 1 Containment Auxiliary Building Open Sleeve 28 14 3 42 107 615.75 153.94 M-282 Detail Section B-B C 584.25 254.469 P-18 M-281 M-661 1-CF-004-10" 4A Unit 1 Containment Auxiliary Building Open Sleeve 18 10 42 102-45 254.47 78.54 M-282 Detail Section B-B C 584.25 254.469 P-20 M-281 M-661 1-CF-003-10" 4A Unit 1 Containment Auxiliary Building Open Sleeve 18 10 42 100-45 254.47 78.54 M-282 Detail Section B-B C 584.25 615.7522 P-21 M-281 M-661 Unit 1 Containment Auxiliary Building Open Sleeve 28 42 98-30 615.75 M-282 Detail Section B-B C 584.25 254.469 P-67 M-281 M-661 Unit 1 Containment Auxiliary Building Open Sleeve 18 42 108-15' 254.47 M-282 Detail Section B-B C 584.25 254.469 P-73 M-281 M-661 Unit 1 Containment Auxiliary Building Open Sleeve 18 42 104-45' 254.47 M-282 Detail Section B-B C 584.25 78.53982 P-87 M-281 M-661 Unit 1 Containment Auxiliary Building Open Sleeve 10 42 96-15' 78.54 M-282 Detail Section B-B C 584.25 78.53982 P-90 M-282 M-661 Unit 1 Containment Auxiliary Building Open Sleeve 10 42 78.54 M-282 Table has at 599'9" Section B-B has at 584' 3" C 586.83 113.0973 P-19 M-281 M-661 1-CC-091-6" 4 Unit 1 Containment Auxiliary Building Open Sleeve 12 6 42 107 113.10 28.27 M-282 Detail Section B-B C 586.83 113.0973 P-23 M-281 M-661 1-CC-106-6" 4 Unit 1 Containment Auxiliary Building Open Sleeve 12 6 1 42 100-45 113.10 28.27 M-282 Detail Section B-B C 586.8 28.27433 P-54 M-281 M-661 1-CS-063-2" 5 Unit 1 Containment Auxiliary Building Open Sleeve 6 2 42 109-15' 28.27 3.14 M-282 Detail Section B-B C 586.83 78.53982 P-64 M-281 M-661 Unit 1 Containment Auxiliary Building Open Sleeve 10 42 94 78.54 M-282 Detail Section B-B C 586.83 153.938 P-74 M-281 M-661 1-FW-012-3" 4 Unit 1 Containment Auxiliary Building Open Sleeve 14 3 42 104-45' 153.94 7.07 M-282 Detail Section B-B C 586.83 78.53982 P-86 M-282 M-661 1-SS-001,2,3-xx" 7 Unit 1 Containment Auxiliary Building Open Sleeve 10 4 pipes 1 42 102-45' 78.54 4 pipes M-282 Detail Section B-B C 586.83 113.0973 P-88 M-281 M-661 1-HS-030-2" 2 Unit 1 Containment Auxiliary Building Open Sleeve 12 2 1.5 42 98-30' 113.10 3.14 M-282 Detail Section B-B C 586.83 113.0973 P-89 M-281 M-661 0-HS-053-2" 2 Unit 1 Containment Auxiliary Building Open Sleeve 12 2 1.5 42 96-15' 113.10 3.14 M-282 Detail Section B-B C 588.83 28.27433 P-2 M-281 M-661 Unit 1 Containment Auxiliary Building Open Sleeve 6 42 98-30 28.27 M-282 Detail Section B-B C 588.83 153.938 P-24 M-281 M-661 1-SI-104-4" 2 Unit 1 Containment Auxiliary Building Open Sleeve 14 4 3 42 107 153.94 12.57 M-282 Detail Section B-B C 588.83 113.0973 P-33 M-281 M-661 1-CC-104-3" 4 Unit 1 Containment Auxiliary Building Open Sleeve 12 3 42 102-45' 113.10 7.07 M-282 Detail Section B-B C 588.83 113.0973 P-34 M-281 M-661 1-DW-006-2" 5 Unit 1 Containment Auxiliary Building Open Sleeve 12 2 42 96-15' 113.10 3.14 M-282 Detail Section B-B C 588.83 153.938 P-71 M-281 M-661 1-BD-001-2 1/2" 2 Unit 1 Containment Auxiliary Building Open Sleeve 14 2.5 42 104-45' 153.94 4.91 M-282 Detail Section B-B C 588.83 153.938 P-76 M-282 M-662 2-SS-026-xx" Unit 1 Containment Auxiliary Building Open Sleeve 14 4 pipes 42 109-15' 153.94 4 pipes M-282 Detail Section B-B C 588.83 78.53982 P-84 M-281 M-661 Unit 1 Containment Auxiliary Building Open Sleeve 10 42 94 78.54 M-282 Detail Section B-B C 588.83 78.53982 P-85 M-281 M-661 Unit 1 Containment Auxiliary Building Open Sleeve 10 42 100-45' 78.54 M-282 Detail Section B-B