C1 to TB Group Elevation Area open to flow (in2)

Penetration No.

Unit 1 DWG Unit 2 DWG Line Ident No. Pen Type From Building To Building End Sate Sleeve Size inches Pipe Size inches Insul Thickness in Dwg B-210 Length in Unit 1 Azimuth Degrees -

minutes Sleeve Area Below 588' in2 Pipe Area Below 588' in2 Sleeve Area Below 579' in2 Pipe Area Below 579' in2 Remarks B

578.08 201.0619 P-127 M-282 M-662 1-MS-018-6" 1

Unit 1 Containment Unit 1 Steam Tunnel Open Sleeve 16 6

3 42 213 201.06 28.27 201.06 28.27 M-282 Detail Section A-A A

578.08 201.0619 P-128 M-282 M-662 1-MS-017-6" 1

Unit 1 Containment Unit 1 Steam Tunnel Open Sleeve 16 6

3 42 333 201.06 28.27 201.06 28.27 M-282 Detail Section A-A B

579.5 1963.495 P-5 M-281 M-661 1-MS-001-34" 1

Unit 1 Containment Unit 1 Steam Tunnel Open Sleeve 50 34 3

42 213 1963.50 907.92 See Location Plan DWG M-282, Detail Section A-A B

579.5 1963.495 P-6 M-281 M-661 1-MS-002-34" 1

Unit 1 Containment Unit 1 Steam Tunnel Open Sleeve 50 34 3

42 213 1963.50 907.92 M-282 Detail Section A-A B

579.5 1963.495 P-7 M-281 M-661 1-MS-003-34" 1

Unit 1 Containment Unit 1 Steam Tunnel Open Sleeve 50 35.5 3

42 333 1963.50 989.80 M-282 Detail Section A-A B

579.5 1963.495 P-8 M-281 M-661 1-MS-004-34" 1

Unit 1 Containment Unit 1 Steam Tunnel Open Sleeve 50 35.5 3

42 333 1963.50 989.80 M-282 Detail Section A-A B

580.083 201.0619 P-112 M-282 M-662 1-SS-041-3/8" 2A Unit 1 Containment Unit 1 Steam Tunnel Open Sleeve 16 0.03125 42 213 201.06 0.00 Line Capped M-282 Detail Section A-A A

580.083 176.7146 P-113 M-282 M-662 1-SS-041-3/8" 2A Unit 1 Containment Unit 1 Steam Tunnel Open Sleeve 15 0.03125 42 333 176.71 0.00 Line Capped M-282 Detail Section A-A B

580.33 153.938 P-95 M-281 M-661 1-BD-007-2" 1

Unit 1 Containment Unit 1 Steam Tunnel Open Sleeve 14 2

42 213 153.94 3.14 M-282 Detail Section A-A B

580.33 153.938 P-96 M-281 M-661 1-BD-005-2" 1

Unit 1 Containment Unit 1 Steam Tunnel Open Sleeve 14 2

42 213 153.94 3.14 M-282 Detail Section A-A A

580.33 153.938 P-97 M-281 M-661 1-BD-003-2" 1

Unit 1 Containment Unit 1 Steam Tunnel Open Sleeve 14 2

42 333 153.94 3.14 M-282 Detail Section A-A A

580.33 153.938 P-98 M-281 M-661 1-BD-001-2" 1

Unit 1 Containment Unit 1 Steam Tunnel Open Sleeve 14 2

42 333 153.94 3.14 M-282 Detail Section A-A B

584.6 804.2477 P-9 M-281 M-661 1-FW-014-16" 1

Unit 1 Containment Unit 1 Steam Tunnel Open Sleeve 32 16 3

42 213 804.25 201.06 M-282 Detail Section A-A B

584.6 804.2477 P-10 M-281 M-661 1-FW-017-16" 1

Unit 1 Containment Unit 1 Steam Tunnel Open Sleeve 32 16 3

42 213 804.25 201.06 M-282 Detail Section A-A A

584.6 804.2477 P-11 M-281 M-661 1-FW-011-16" 1

Unit 1 Containment Unit 1 Steam Tunnel Open Sleeve 32 16 3

42 333 804.25 201.06 M-282 Detail Section A-A B

584.58 201.0619 P-91 M-281 M-661 1-BD-007-2 1/2" 2A Unit 1 Containment Unit 1 Steam Tunnel Open Sleeve 16 2.5 42 213 201.06 4.91 M-282 Detail Section A-A B

584.58 201.0619 P-92 M-281 M-661 1-BD-008-2" 1

Unit 1 Containment Unit 1 Steam Tunnel Open Sleeve 16 2

42 213 201.06 3.14 M-282 Detail Section A-A B

584.58 201.0619 P-93 M-281 M-661 1-BD-006-2" 1

Unit 1 Containment Unit 1 Steam Tunnel Open Sleeve 16 2

42 213 201.06 3.14 M-282 Detail Section A-A B

584.58 201.0619 P-94 M-281 M-661 1-BD-005-2 1/2" 2A Unit 1 Containment Unit 1 Steam Tunnel Open Sleeve 16 2.5 42 213 201.06 4.91 M-282 Detail Section A-A A

584.58 201.0619 P-115 M-282 M-662 1-BD-003-2 1/2" 2A Unit 1 Containment Unit 1 Steam Tunnel Open Sleeve 16 2.5 3

42 333 201.06 4.91 M-282 Detail Section A-A A

584.58 201.0619 P-116 M-282 M-662 1-BD-004-2" 1A Unit 1 Containment Unit 1 Steam Tunnel Open Sleeve 16 2

3 42 333 201.06 3.14 M-282 Detail Section A-A A

584.58 201.0619 P-117 M-282 M-662 1-BD-002-2" 1A Unit 1 Containment Unit 1 Steam Tunnel Open Sleeve 16 2

3 42 333 201.06 3.14 M-282 Detail Section A-A A

584.58 201.0619 P-118 M-282 M-662 1-BD-001-2 1/2" 2A Unit 1 Containment Unit 1 Steam Tunnel Open Sleeve 16 2.5 3

42 333 201.06 4.91 M-282 Detail Section A-A A

586.8 804.2477 P-12 M-281 M-661 1-FW-022-16" 1

Unit 1 Containment Unit 1 Steam Tunnel Open Sleeve 32 16 3

42 333 804.25 201.06 M-282 Detail Section A-A