ML17129A367
Text
RESRAD, Version 7.0 T1/2 Limit = 30 days 12/06/2014 14:01 Page 1 Summary : Zion Surface Soil 0.01 m^2 120614 File : C:\\RESRAD_FAMILY\\RESRAD\\7.0\\USERFILES\\ZION SURFACE SOIL DCGL.RAD Table of Contents Part I: Mixture Sums and Single Radionuclide Guidelines Dose Conversion Factor (and Related) Parameter Summary... 2 Site-Specific Parameter Summary.......................... 4 Summary of Pathway Selections............................ 8 Contaminated Zone and Total Dose Summary................. 9 Total Dose Components Time = 0.000E+00.................................... 10 Time = 1.000E+00.................................... 11 Time = 3.000E+00.................................... 12 Time = 1.000E+01.................................... 13 Time = 3.000E+01.................................... 14 Time = 1.000E+02.................................... 15 Time = 3.000E+02.................................... 16 Time = 1.000E+03.................................... 17 Dose/Source Ratios Summed Over All Pathways.............. 18 Single Radionuclide Soil Guidelines...................... 18 Dose Per Nuclide Summed Over All Pathways................ 19 Soil Concentration Per Nuclide........................... 19
RESRAD, Version 7.0 T1/2 Limit = 30 days 12/06/2014 14:01 Page 2 Summary : Zion Surface Soil 0.01 m^2 120614 File : C:\\RESRAD_FAMILY\\RESRAD\\7.0\\USERFILES\\ZION SURFACE SOIL DCGL.RAD Dose Conversion Factor (and Related) Parameter Summary Dose Library: Surface Soil DCGL Plus FGR 11 Current Base Parameter Menu Parameter Value# Case* Name HHHH A-1 DCF's for external ground radiation, (mrem/yr)/(pCi/g)
A-1 Ba-137m (Source: FGR 12) 3.606E+00 3.606E+00 DCF1( 1)
A-1 Co-60 (Source: FGR 12) 1.622E+01 1.622E+01 DCF1( 2)
A-1 Cs-134 (Source: FGR 12) 9.472E+00 9.472E+00 DCF1( 3)
A-1 Cs-137 (Source: FGR 12) 7.510E-04 7.510E-04 DCF1( 4)
A-1 Ni-63 (Source: FGR 12) 0.000E+00 0.000E+00 DCF1( 5)
A-1 Sr-90 (Source: FGR 12) 7.043E-04 7.043E-04 DCF1( 6)
A-1 Y-90 (Source: FGR 12) 2.391E-02 2.391E-02 DCF1( 7)
B-1 Dose conversion factors for inhalation, mrem/pCi:
B-1 Co-60 2.190E-04 2.190E-04 DCF2( 1)
B-1 Cs-134 4.620E-05 4.620E-05 DCF2( 2)
B-1 Cs-137+D 3.190E-05 3.190E-05 DCF2( 3)
B-1 Ni-63 6.290E-06 6.290E-06 DCF2( 4)
B-1 Sr-90+D 1.308E-03 1.300E-03 DCF2( 5)
D-1 Dose conversion factors for ingestion, mrem/pCi:
D-1 Co-60 2.690E-05 2.690E-05 DCF3( 1)
D-1 Cs-134 7.330E-05 7.330E-05 DCF3( 2)
D-1 Cs-137+D 5.000E-05 5.000E-05 DCF3( 3)
D-1 Ni-63 5.770E-07 5.770E-07 DCF3( 4)
D-1 Sr-90+D 1.528E-04 1.420E-04 DCF3( 5)
D-34 Food transfer factors:
D-34 Co-60, plant/soil concentration ratio, dimensionless 1.500E-01 8.000E-02 RTF( 1,1)
D-34 Co-60, beef/livestock-intake ratio, (pCi/kg)/(pCi/d) 5.800E-02 2.000E-02 RTF( 1,2)
D-34 Co-60, milk/livestock-intake ratio, (pCi/L)/(pCi/d) 2.000E-03 2.000E-03 RTF( 1,3)
D-34 D-34 Cs-134, plant/soil concentration ratio, dimensionless 7.800E-02 4.000E-02 RTF( 2,1)
D-34 Cs-134, beef/livestock-intake ratio, (pCi/kg)/(pCi/d) 6.500E-02 3.000E-02 RTF( 2,2)
D-34 Cs-134, milk/livestock-intake ratio, (pCi/L)/(pCi/d) 1.400E-02 8.000E-03 RTF( 2,3)
D-34 D-34 Cs-137+D, plant/soil concentration ratio, dimensionless 7.800E-02 4.000E-02 RTF( 3,1)
D-34 Cs-137+D, beef/livestock-intake ratio, (pCi/kg)/(pCi/d) 6.500E-02 3.000E-02 RTF( 3,2)
D-34 Cs-137+D, milk/livestock-intake ratio, (pCi/L)/(pCi/d) 1.400E-02 8.000E-03 RTF( 3,3)
D-34 D-34 Ni-63, plant/soil concentration ratio, dimensionless 9.200E-02 5.000E-02 RTF( 4,1)
D-34 Ni-63, beef/livestock-intake ratio, (pCi/kg)/(pCi/d) 5.000E-03 5.000E-03 RTF( 4,2)
D-34 Ni-63, milk/livestock-intake ratio, (pCi/L)/(pCi/d) 3.200E-02 2.000E-02 RTF( 4,3)
D-34 D-34 Sr-90+D, plant/soil concentration ratio, dimensionless 5.900E-01 3.000E-01 RTF( 5,1)
D-34 Sr-90+D, beef/livestock-intake ratio, (pCi/kg)/(pCi/d) 8.000E-03 8.000E-03 RTF( 5,2)
D-34 Sr-90+D, milk/livestock-intake ratio, (pCi/L)/(pCi/d) 2.700E-03 2.000E-03 RTF( 5,3)
D-5 Bioaccumulation factors, fresh water, L/kg:
D-5 Co-60, fish 3.000E+02 3.000E+02 BIOFAC( 1,1)
D-5 Co-60, crustacea and mollusks 2.000E+02 2.000E+02 BIOFAC( 1,2)
D-5 D-5 Cs-134, fish 2.000E+03 2.000E+03 BIOFAC( 2,1)
D-5 Cs-134, crustacea and mollusks 1.000E+02 1.000E+02 BIOFAC( 2,2)
RESRAD, Version 7.0 T1/2 Limit = 30 days 12/06/2014 14:01 Page 3 Summary : Zion Surface Soil 0.01 m^2 120614 File : C:\\RESRAD_FAMILY\\RESRAD\\7.0\\USERFILES\\ZION SURFACE SOIL DCGL.RAD Dose Conversion Factor (and Related) Parameter Summary (continued)
Dose Library: Surface Soil DCGL Plus FGR 11 Current Base Parameter Menu Parameter Value# Case* Name HHHH D-5 Cs-137+D, fish 2.000E+03 2.000E+03 BIOFAC( 3,1)
D-5 Cs-137+D, crustacea and mollusks 1.000E+02 1.000E+02 BIOFAC( 3,2)
D-5 D-5 Ni-63, fish 1.000E+02 1.000E+02 BIOFAC( 4,1)
D-5 Ni-63, crustacea and mollusks 1.000E+02 1.000E+02 BIOFAC( 4,2)
D-5 D-5 Sr-90+D, fish 6.000E+01 6.000E+01 BIOFAC( 5,1)
D-5 Sr-90+D, crustacea and mollusks 1.000E+02 1.000E+02 BIOFAC( 5,2)
- For DCF1(xxx) only, factors are for infinite depth & area. See ETFG table in Ground Pathway of Detailed Report.
- Base Case means Default.Lib w/o Associate Nuclide contributions.
RESRAD, Version 7.0 T1/2 Limit = 30 days 12/06/2014 14:01 Page 4 Summary : Zion Surface Soil 0.01 m^2 120614 File : C:\\RESRAD_FAMILY\\RESRAD\\7.0\\USERFILES\\ZION SURFACE SOIL DCGL.RAD Site-Specific Parameter Summary User Used by RESRAD Parameter Menu Parameter Input Default (If different from user input) Name HHHHH R011 Area of contaminated zone (m**2) 1.000E-02 1.000E+04 --- AREA R011 Thickness of contaminated zone (m) 1.500E-01 2.000E+00 --- THICK0 R011 Fraction of contamination that is submerged 0.000E+00 0.000E+00 --- SUBMFRACT R011 Length parallel to aquifer flow (m) 1.100E-01 1.000E+02 --- LCZPAQ R011 Basic radiation dose limit (mrem/yr) 2.500E+01 3.000E+01 --- BRDL R011 Time since placement of material (yr) 0.000E+00 0.000E+00 --- TI R011 Times for calculations (yr) 1.000E+00 1.000E+00 --- T( 2)
R011 Times for calculations (yr) 3.000E+00 3.000E+00 --- T( 3)
R011 Times for calculations (yr) 1.000E+01 1.000E+01 --- T( 4)
R011 Times for calculations (yr) 3.000E+01 3.000E+01 --- T( 5)
R011 Times for calculations (yr) 1.000E+02 1.000E+02 --- T( 6)
R011 Times for calculations (yr) 3.000E+02 3.000E+02 --- T( 7)
R011 Times for calculations (yr) 1.000E+03 1.000E+03 --- T( 8)
R011 Times for calculations (yr) not used 0.000E+00 --- T( 9)
R011 Times for calculations (yr) not used 0.000E+00 --- T(10)
R012 Initial principal radionuclide (pCi/g): Co-60 1.000E+00 0.000E+00 --- S1(1)
R012 Initial principal radionuclide (pCi/g): Cs-134 1.000E+00 0.000E+00 --- S1(2)
R012 Initial principal radionuclide (pCi/g): Cs-137 1.000E+00 0.000E+00 --- S1(3)
R012 Initial principal radionuclide (pCi/g): Ni-63 1.000E+00 0.000E+00 --- S1(4)
R012 Initial principal radionuclide (pCi/g): Sr-90 1.000E+00 0.000E+00 --- S1(5)
R012 Concentration in groundwater (pCi/L): Co-60 not used 0.000E+00 --- W1( 1)
R012 Concentration in groundwater (pCi/L): Cs-134 not used 0.000E+00 --- W1( 2)
R012 Concentration in groundwater (pCi/L): Cs-137 not used 0.000E+00 --- W1( 3)
R012 Concentration in groundwater (pCi/L): Ni-63 not used 0.000E+00 --- W1( 4)
R012 Concentration in groundwater (pCi/L): Sr-90 not used 0.000E+00 --- W1( 5)
R013 Cover depth (m) 0.000E+00 0.000E+00 --- COVER0 R013 Density of cover material (g/cm**3) not used 1.500E+00 --- DENSCV R013 Cover depth erosion rate (m/yr) not used 1.000E-03 --- VCV R013 Density of contaminated zone (g/cm**3) 1.800E+00 1.500E+00 --- DENSCZ R013 Contaminated zone erosion rate (m/yr) 1.500E-03 1.000E-03 --- VCZ R013 Contaminated zone total porosity 3.500E-01 4.000E-01 --- TPCZ R013 Contaminated zone field capacity 6.600E-02 2.000E-01 --- FCCZ R013 Contaminated zone hydraulic conductivity (m/yr) 2.880E+03 1.000E+01 --- HCCZ R013 Contaminated zone b parameter 9.700E-01 5.300E+00 --- BCZ R013 Average annual wind speed (m/sec) 4.200E+00 2.000E+00 --- WIND R013 Humidity in air (g/m**3) not used 8.000E+00 --- HUMID R013 Evapotranspiration coefficient 6.250E-01 5.000E-01 --- EVAPTR R013 Precipitation (m/yr) 8.300E-01 1.000E+00 --- PRECIP R013 Irrigation (m/yr) 1.900E-01 2.000E-01 --- RI R013 Irrigation mode overhead overhead --- IDITCH R013 Runoff coefficient 2.000E-01 2.000E-01 --- RUNOFF R013 Watershed area for nearby stream or pond (m**2) 1.000E+06 1.000E+06 --- WAREA R013 Accuracy for water/soil computations 1.000E-03 1.000E-03 --- EPS R014 Density of saturated zone (g/cm**3) 1.800E+00 1.500E+00 --- DENSAQ R014 Saturated zone total porosity 3.500E-01 4.000E-01 --- TPSZ R014 Saturated zone effective porosity 2.900E-01 2.000E-01 --- EPSZ R014 Saturated zone field capacity 6.600E-02 2.000E-01 --- FCSZ
RESRAD, Version 7.0 T1/2 Limit = 30 days 12/06/2014 14:01 Page 5 Summary : Zion Surface Soil 0.01 m^2 120614 File : C:\\RESRAD_FAMILY\\RESRAD\\7.0\\USERFILES\\ZION SURFACE SOIL DCGL.RAD Site-Specific Parameter Summary (continued)
User Used by RESRAD Parameter Menu Parameter Input Default (If different from user input) Name HHHHH R014 Saturated zone hydraulic conductivity (m/yr) 2.880E+03 1.000E+02 --- HCSZ R014 Saturated zone hydraulic gradient 3.900E-03 2.000E-02 --- HGWT R014 Saturated zone b parameter not used 5.300E+00 --- BSZ R014 Water table drop rate (m/yr) 0.000E+00 1.000E-03 --- VWT R014 Well pump intake depth (m below water table) 3.300E+00 1.000E+01 --- DWIBWT R014 Model: Nondispersion (ND) or Mass-Balance (MB) ND ND --- MODEL R014 Well pumping rate (m**3/yr) 2.250E+03 2.500E+02 --- UW R015 Number of unsaturated zone strata 1 1 --- NS R015 Unsat. zone 1, thickness (m) 3.450E+00 4.000E+00 --- H(1)
R015 Unsat. zone 1, soil density (g/cm**3) 1.800E+00 1.500E+00 --- DENSUZ(1)
R015 Unsat. zone 1, total porosity 3.500E-01 4.000E-01 --- TPUZ(1)
R015 Unsat. zone 1, effective porosity 2.900E-01 2.000E-01 --- EPUZ(1)
R015 Unsat. zone 1, field capacity 6.600E-02 2.000E-01 --- FCUZ(1)
R015 Unsat. zone 1, soil-specific b parameter 9.700E-01 5.300E+00 --- BUZ(1)
R015 Unsat. zone 1, hydraulic conductivity (m/yr) 2.880E+03 1.000E+01 --- HCUZ(1)
R016 Distribution coefficients for Co-60 R016 Contaminated zone (cm**3/g) 1.161E+03 1.000E+03 --- DCNUCC( 1)
R016 Unsaturated zone 1 (cm**3/g) 1.161E+03 1.000E+03 --- DCNUCU( 1,1)
R016 Saturated zone (cm**3/g) 1.161E+03 1.000E+03 --- DCNUCS( 1)
R016 Leach rate (/yr) 0.000E+00 0.000E+00 1.022E-03 ALEACH( 1)
R016 Solubility constant 0.000E+00 0.000E+00 not used SOLUBK( 1)
R016 Distribution coefficients for Cs-134 R016 Contaminated zone (cm**3/g) 6.150E+02 4.600E+03 --- DCNUCC( 2)
R016 Unsaturated zone 1 (cm**3/g) 6.150E+02 4.600E+03 --- DCNUCU( 2,1)
R016 Saturated zone (cm**3/g) 6.150E+02 4.600E+03 --- DCNUCS( 2)
R016 Leach rate (/yr) 0.000E+00 0.000E+00 1.929E-03 ALEACH( 2)
R016 Solubility constant 0.000E+00 0.000E+00 not used SOLUBK( 2)
R016 Distribution coefficients for Cs-137 R016 Contaminated zone (cm**3/g) 6.150E+02 4.600E+03 --- DCNUCC( 3)
R016 Unsaturated zone 1 (cm**3/g) 6.150E+02 4.600E+03 --- DCNUCU( 3,1)
R016 Saturated zone (cm**3/g) 6.150E+02 4.600E+03 --- DCNUCS( 3)
R016 Leach rate (/yr) 0.000E+00 0.000E+00 1.929E-03 ALEACH( 3)
R016 Solubility constant 0.000E+00 0.000E+00 not used SOLUBK( 3)
R016 Distribution coefficients for Ni-63 R016 Contaminated zone (cm**3/g) 6.200E+01 1.000E+03 --- DCNUCC( 4)
R016 Unsaturated zone 1 (cm**3/g) 6.200E+01 1.000E+03 --- DCNUCU( 4,1)
R016 Saturated zone (cm**3/g) 6.200E+01 1.000E+03 --- DCNUCS( 4)
R016 Leach rate (/yr) 0.000E+00 0.000E+00 1.912E-02 ALEACH( 4)
R016 Solubility constant 0.000E+00 0.000E+00 not used SOLUBK( 4)
R016 Distribution coefficients for Sr-90 R016 Contaminated zone (cm**3/g) 2.300E+00 3.000E+01 --- DCNUCC( 5)
R016 Unsaturated zone 1 (cm**3/g) 2.300E+00 3.000E+01 --- DCNUCU( 5,1)
R016 Saturated zone (cm**3/g) 2.300E+00 3.000E+01 --- DCNUCS( 5)
R016 Leach rate (/yr) 0.000E+00 0.000E+00 5.076E-01 ALEACH( 5)
R016 Solubility constant 0.000E+00 0.000E+00 not used SOLUBK( 5)
RESRAD, Version 7.0 T1/2 Limit = 30 days 12/06/2014 14:01 Page 6 Summary : Zion Surface Soil 0.01 m^2 120614 File : C:\\RESRAD_FAMILY\\RESRAD\\7.0\\USERFILES\\ZION SURFACE SOIL DCGL.RAD Site-Specific Parameter Summary (continued)
User Used by RESRAD Parameter Menu Parameter Input Default (If different from user input) Name HHHHH R017 Inhalation rate (m**3/yr) 8.400E+03 8.400E+03 --- INHALR R017 Mass loading for inhalation (g/m**3) 2.350E-05 1.000E-04 --- MLINH R017 Exposure duration 3.000E+01 3.000E+01 --- ED R017 Shielding factor, inhalation 5.500E-01 4.000E-01 --- SHF3 R017 Shielding factor, external gamma 4.000E-01 7.000E-01 --- SHF1 R017 Fraction of time spent indoors 6.490E-01 5.000E-01 --- FIND R017 Fraction of time spent outdoors (on site) 1.240E-01 2.500E-01 --- FOTD R017 Shape factor flag, external gamma 1.000E+00 1.000E+00 >0 shows circular AREA. FS R017 Radii of shape factor array (used if FS = -1):
R017 Outer annular radius (m), ring 1: not used 5.000E+01 --- RAD_SHAPE( 1)
R017 Outer annular radius (m), ring 2: not used 7.071E+01 --- RAD_SHAPE( 2)
R017 Outer annular radius (m), ring 3: not used 0.000E+00 --- RAD_SHAPE( 3)
R017 Outer annular radius (m), ring 4: not used 0.000E+00 --- RAD_SHAPE( 4)
R017 Outer annular radius (m), ring 5: not used 0.000E+00 --- RAD_SHAPE( 5)
R017 Outer annular radius (m), ring 6: not used 0.000E+00 --- RAD_SHAPE( 6)
R017 Outer annular radius (m), ring 7: not used 0.000E+00 --- RAD_SHAPE( 7)
R017 Outer annular radius (m), ring 8: not used 0.000E+00 --- RAD_SHAPE( 8)
R017 Outer annular radius (m), ring 9: not used 0.000E+00 --- RAD_SHAPE( 9)
R017 Outer annular radius (m), ring 10: not used 0.000E+00 --- RAD_SHAPE(10)
R017 Outer annular radius (m), ring 11: not used 0.000E+00 --- RAD_SHAPE(11)
R017 Outer annular radius (m), ring 12: not used 0.000E+00 --- RAD_SHAPE(12)
R017 Fractions of annular areas within AREA:
R017 Ring 1 not used 1.000E+00 --- FRACA( 1)
R017 Ring 2 not used 2.732E-01 --- FRACA( 2)
R017 Ring 3 not used 0.000E+00 --- FRACA( 3)
R017 Ring 4 not used 0.000E+00 --- FRACA( 4)
R017 Ring 5 not used 0.000E+00 --- FRACA( 5)
R017 Ring 6 not used 0.000E+00 --- FRACA( 6)
R017 Ring 7 not used 0.000E+00 --- FRACA( 7)
R017 Ring 8 not used 0.000E+00 --- FRACA( 8)
R017 Ring 9 not used 0.000E+00 --- FRACA( 9)
R017 Ring 10 not used 0.000E+00 --- FRACA(10)
R017 Ring 11 not used 0.000E+00 --- FRACA(11)
R017 Ring 12 not used 0.000E+00 --- FRACA(12)
R018 Fruits, vegetables and grain consumption (kg/yr) 1.120E+02 1.600E+02 --- DIET(1)
R018 Leafy vegetable consumption (kg/yr) 2.140E+01 1.400E+01 --- DIET(2)
R018 Milk consumption (L/yr) 2.330E+02 9.200E+01 --- DIET(3)
R018 Meat and poultry consumption (kg/yr) 6.510E+01 6.300E+01 --- DIET(4)
R018 Fish consumption (kg/yr) not used 5.400E+00 --- DIET(5)
R018 Other seafood consumption (kg/yr) not used 9.000E-01 --- DIET(6)
R018 Soil ingestion rate (g/yr) 1.830E+01 3.650E+01 --- SOIL R018 Drinking water intake (L/yr) 4.780E+02 5.100E+02 --- DWI R018 Contamination fraction of drinking water 1.000E+00 1.000E+00 --- FDW R018 Contamination fraction of household water not used 1.000E+00 --- FHHW R018 Contamination fraction of livestock water 1.000E+00 1.000E+00 --- FLW R018 Contamination fraction of irrigation water 1.000E+00 1.000E+00 --- FIRW R018 Contamination fraction of aquatic food not used 5.000E-01 --- FR9 R018 Contamination fraction of plant food -1 -1 0.500E-05 FPLANT
RESRAD, Version 7.0 T1/2 Limit = 30 days 12/06/2014 14:01 Page 7 Summary : Zion Surface Soil 0.01 m^2 120614 File : C:\\RESRAD_FAMILY\\RESRAD\\7.0\\USERFILES\\ZION SURFACE SOIL DCGL.RAD Site-Specific Parameter Summary (continued)
User Used by RESRAD Parameter Menu Parameter Input Default (If different from user input) Name HHHHH R018 Contamination fraction of meat -1 -1 0.500E-06 FMEAT R018 Contamination fraction of milk -1 -1 0.500E-06 FMILK R019 Livestock fodder intake for meat (kg/day) 2.830E+01 6.800E+01 --- LFI5 R019 Livestock fodder intake for milk (kg/day) 6.520E+01 5.500E+01 --- LFI6 R019 Livestock water intake for meat (L/day) 5.060E+01 5.000E+01 --- LWI5 R019 Livestock water intake for milk (L/day) 6.000E+01 1.600E+02 --- LWI6 R019 Livestock soil intake (kg/day) 5.000E-01 5.000E-01 --- LSI R019 Mass loading for foliar deposition (g/m**3) 4.000E-04 1.000E-04 --- MLFD R019 Depth of soil mixing layer (m) 1.500E-01 1.500E-01 --- DM R019 Depth of roots (m) 1.220E+00 9.000E-01 --- DROOT R019 Drinking water fraction from ground water 1.000E+00 1.000E+00 --- FGWDW R019 Household water fraction from ground water not used 1.000E+00 --- FGWHH R019 Livestock water fraction from ground water 1.000E+00 1.000E+00 --- FGWLW R019 Irrigation fraction from ground water 1.000E+00 1.000E+00 --- FGWIR R19B Wet weight crop yield for Non-Leafy (kg/m**2) 1.750E+00 7.000E-01 --- YV(1)
R19B Wet weight crop yield for Leafy (kg/m**2) 2.900E+00 1.500E+00 --- YV(2)
R19B Wet weight crop yield for Fodder (kg/m**2) 1.900E+00 1.100E+00 --- YV(3)
R19B Growing Season for Non-Leafy (years) 2.460E-01 1.700E-01 --- TE(1)
R19B Growing Season for Leafy (years) 1.230E-01 2.500E-01 --- TE(2)
R19B Growing Season for Fodder (years) 8.200E-02 8.000E-02 --- TE(3)
R19B Translocation Factor for Non-Leafy 1.000E-01 1.000E-01 --- TIV(1)
R19B Translocation Factor for Leafy 1.000E+00 1.000E+00 --- TIV(2)
R19B Translocation Factor for Fodder 1.000E+00 1.000E+00 --- TIV(3)
R19B Dry Foliar Interception Fraction for Non-Leafy 3.500E-01 2.500E-01 --- RDRY(1)
R19B Dry Foliar Interception Fraction for Leafy 3.500E-01 2.500E-01 --- RDRY(2)
R19B Dry Foliar Interception Fraction for Fodder 3.500E-01 2.500E-01 --- RDRY(3)
R19B Wet Foliar Interception Fraction for Non-Leafy 3.500E-01 2.500E-01 --- RWET(1)
R19B Wet Foliar Interception Fraction for Leafy 5.800E-01 2.500E-01 --- RWET(2)
R19B Wet Foliar Interception Fraction for Fodder 3.500E-01 2.500E-01 --- RWET(3)
R19B Weathering Removal Constant for Vegetation 3.300E+01 2.000E+01 --- WLAM C14 C-12 concentration in water (g/cm**3) not used 2.000E-05 --- C12WTR C14 C-12 concentration in contaminated soil (g/g) not used 3.000E-02 --- C12CZ C14 Fraction of vegetation carbon from soil not used 2.000E-02 --- CSOIL C14 Fraction of vegetation carbon from air not used 9.800E-01 --- CAIR C14 C-14 evasion layer thickness in soil (m) not used 3.000E-01 --- DMC C14 C-14 evasion flux rate from soil (1/sec) not used 7.000E-07 --- EVSN C14 C-12 evasion flux rate from soil (1/sec) not used 1.000E-10 --- REVSN C14 Fraction of grain in beef cattle feed not used 8.000E-01 --- AVFG4 C14 Fraction of grain in milk cow feed not used 2.000E-01 --- AVFG5 STOR Storage times of contaminated foodstuffs (days):
STOR Fruits, non-leafy vegetables, and grain 1.400E+01 1.400E+01 --- STOR_T(1)
STOR Leafy vegetables 1.000E+00 1.000E+00 --- STOR_T(2)
STOR Milk 1.000E+00 1.000E+00 --- STOR_T(3)
STOR Meat and poultry 1.000E+00 2.000E+01 --- STOR_T(4)
STOR Fish 7.000E+00 7.000E+00 --- STOR_T(5)
STOR Crustacea and mollusks 7.000E+00 7.000E+00 --- STOR_T(6)
RESRAD, Version 7.0 T1/2 Limit = 30 days 12/06/2014 14:01 Page 8 Summary : Zion Surface Soil 0.01 m^2 120614 File : C:\\RESRAD_FAMILY\\RESRAD\\7.0\\USERFILES\\ZION SURFACE SOIL DCGL.RAD Site-Specific Parameter Summary (continued)
User Used by RESRAD Parameter Menu Parameter Input Default (If different from user input) Name HHHHH STOR Well water 1.000E+00 1.000E+00 --- STOR_T(7)
STOR Surface water 1.000E+00 1.000E+00 --- STOR_T(8)
STOR Livestock fodder 4.500E+01 4.500E+01 --- STOR_T(9)
R021 Thickness of building foundation (m) not used 1.500E-01 --- FLOOR1 R021 Bulk density of building foundation (g/cm**3) not used 2.400E+00 --- DENSFL R021 Total porosity of the cover material not used 4.000E-01 --- TPCV R021 Total porosity of the building foundation not used 1.000E-01 --- TPFL R021 Volumetric water content of the cover material not used 5.000E-02 --- PH2OCV R021 Volumetric water content of the foundation not used 3.000E-02 --- PH2OFL R021 Diffusion coefficient for radon gas (m/sec):
R021 in cover material not used 2.000E-06 --- DIFCV R021 in foundation material not used 3.000E-07 --- DIFFL R021 in contaminated zone soil not used 2.000E-06 --- DIFCZ R021 Radon vertical dimension of mixing (m) not used 2.000E+00 --- HMIX R021 Average building air exchange rate (1/hr) not used 5.000E-01 --- REXG R021 Height of the building (room) (m) not used 2.500E+00 --- HRM R021 Building interior area factor not used 0.000E+00 --- FAI R021 Building depth below ground surface (m) not used -1.000E+00 --- DMFL R021 Emanating power of Rn-222 gas not used 2.500E-01 --- EMANA(1)
R021 Emanating power of Rn-220 gas not used 1.500E-01 --- EMANA(2)
TITL Number of graphical time points 512 --- --- NPTS TITL Maximum number of integration points for dose 17 --- --- LYMAX TITL Maximum number of integration points for risk 17 --- --- KYMAX
Summary of Pathway Selections Pathway User Selection H
1 -- external gamma active 2 -- inhalation (w/o radon) active 3 -- plant ingestion active 4 -- meat ingestion active 5 -- milk ingestion active 6 -- aquatic foods suppressed 7 -- drinking water active 8 -- soil ingestion active 9 -- radon suppressed Find peak pathway doses active
RESRAD, Version 7.0 T1/2 Limit = 30 days 12/06/2014 14:01 Page 9 Summary : Zion Surface Soil 0.01 m^2 120614 File : C:\\RESRAD_FAMILY\\RESRAD\\7.0\\USERFILES\\ZION SURFACE SOIL DCGL.RAD Contaminated Zone Dimensions Initial Soil Concentrations, pCi/g Area: 0.01 square meters Co-60 1.000E+00 Thickness: 0.15 meters Cs-134 1.000E+00 Cover Depth: 0.00 meters Cs-137 1.000E+00 Ni-63 1.000E+00 Sr-90 1.000E+00 Total Dose TDOSE(t), mrem/yr Basic Radiation Dose Limit = 2.500E+01 mrem/yr Total Mixture Sum M(t) = Fraction of Basic Dose Limit Received at Time (t) t (years): 0.000E+00 1.000E+00 3.000E+00 1.000E+01 3.000E+01 1.000E+02 3.000E+02 1.000E+03 TDOSE(t): 7.811E-03 6.493E-03 4.643E-03 1.888E-03 4.472E-04 8.019E-13 0.000E+00 5.629E-12 M(t): 3.124E-04 2.597E-04 1.857E-04 7.551E-05 1.789E-05 3.207E-14 0.000E+00 2.252E-13 Maximum TDOSE(t): 7.811E-03 mrem/yr at t = 0.000E+00 years
RESRAD, Version 7.0 T1/2 Limit = 30 days 12/06/2014 14:01 Page 10 Summary : Zion Surface Soil 0.01 m^2 120614 File : C:\\RESRAD_FAMILY\\RESRAD\\7.0\\USERFILES\\ZION SURFACE SOIL DCGL.RAD Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)
As mrem/yr and Fraction of Total Dose At t = 0.000E+00 years Water Independent Pathways (Inhalation excludes radon)
Ground Inhalation Radon Plant Meat Milk Soil Radio-Nuclide mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract.
Co-60 4.281E-03 0.5480 3.482E-07 0.0000 0.000E+00 0.0000 3.085E-07 0.0000 4.840E-08 0.0000 9.954E-09 0.0000 3.546E-09 0.0000 Cs-134 2.475E-03 0.3168 6.658E-08 0.0000 0.000E+00 0.0000 3.962E-07 0.0001 1.011E-07 0.0000 1.137E-07 0.0000 8.758E-09 0.0000 Cs-137 1.040E-03 0.1331 5.348E-08 0.0000 0.000E+00 0.0000 3.144E-07 0.0000 8.024E-08 0.0000 9.026E-08 0.0000 6.951E-09 0.0000 Ni-63 0.000E+00 0.0000 1.054E-08 0.0000 0.000E+00 0.0000 4.280E-09 0.0000 7.575E-11 0.0000 2.620E-09 0.0000 8.017E-11 0.0000 Sr-90 6.014E-06 0.0008 1.724E-06 0.0002 0.000E+00 0.0000 5.795E-06 0.0007 8.224E-08 0.0000 2.046E-07 0.0000 1.669E-08 0.0000 Total 7.801E-03 0.9987 2.202E-06 0.0003 0.000E+00 0.0000 6.818E-06 0.0009 3.121E-07 0.0000 4.212E-07 0.0001 3.602E-08 0.0000 Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)
As mrem/yr and Fraction of Total Dose At t = 0.000E+00 years Water Dependent Pathways Water Fish Radon Plant Meat Milk All Pathways*
Radio-Nuclide mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract.
Co-60 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 4.281E-03 0.5481 Cs-134 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 2.476E-03 0.3169 Cs-137 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.040E-03 0.1332 Ni-63 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.760E-08 0.0000 Sr-90 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.384E-05 0.0018 Total 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 7.811E-03 1.0000
- Sum of all water independent and dependent pathways.
RESRAD, Version 7.0 T1/2 Limit = 30 days 12/06/2014 14:01 Page 11 Summary : Zion Surface Soil 0.01 m^2 120614 File : C:\\RESRAD_FAMILY\\RESRAD\\7.0\\USERFILES\\ZION SURFACE SOIL DCGL.RAD Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)
As mrem/yr and Fraction of Total Dose At t = 1.000E+00 years Water Independent Pathways (Inhalation excludes radon)
Ground Inhalation Radon Plant Meat Milk Soil Radio-Nuclide mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract.
Co-60 3.722E-03 0.5733 3.019E-07 0.0000 0.000E+00 0.0000 2.675E-07 0.0000 4.197E-08 0.0000 8.632E-09 0.0000 3.075E-09 0.0000 Cs-134 1.754E-03 0.2701 4.702E-08 0.0000 0.000E+00 0.0000 2.798E-07 0.0000 7.141E-08 0.0000 8.033E-08 0.0000 6.186E-09 0.0000 Cs-137 1.007E-03 0.1551 5.164E-08 0.0000 0.000E+00 0.0000 3.036E-07 0.0000 7.748E-08 0.0000 8.716E-08 0.0000 6.712E-09 0.0000 Ni-63 0.000E+00 0.0000 1.017E-08 0.0000 0.000E+00 0.0000 4.128E-09 0.0000 7.307E-11 0.0000 2.527E-09 0.0000 7.732E-11 0.0000 Sr-90 3.513E-06 0.0005 1.003E-06 0.0002 0.000E+00 0.0000 3.377E-06 0.0005 4.811E-08 0.0000 1.198E-07 0.0000 9.708E-09 0.0000 Total 6.487E-03 0.9990 1.413E-06 0.0002 0.000E+00 0.0000 4.232E-06 0.0007 2.391E-07 0.0000 2.984E-07 0.0000 2.576E-08 0.0000 Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)
As mrem/yr and Fraction of Total Dose At t = 1.000E+00 years Water Dependent Pathways Water Fish Radon Plant Meat Milk All Pathways*
Radio-Nuclide mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract.
Co-60 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 3.723E-03 0.5734 Cs-134 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.754E-03 0.2702 Cs-137 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.008E-03 0.1552 Ni-63 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.697E-08 0.0000 Sr-90 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 8.070E-06 0.0012 Total 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 6.493E-03 1.0000
- Sum of all water independent and dependent pathways.
RESRAD, Version 7.0 T1/2 Limit = 30 days 12/06/2014 14:01 Page 12 Summary : Zion Surface Soil 0.01 m^2 120614 File : C:\\RESRAD_FAMILY\\RESRAD\\7.0\\USERFILES\\ZION SURFACE SOIL DCGL.RAD Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)
As mrem/yr and Fraction of Total Dose At t = 3.000E+00 years Water Independent Pathways (Inhalation excludes radon)
Ground Inhalation Radon Plant Meat Milk Soil Radio-Nuclide mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract.
Co-60 2.814E-03 0.6059 2.269E-07 0.0000 0.000E+00 0.0000 2.011E-07 0.0000 3.155E-08 0.0000 6.488E-09 0.0000 2.311E-09 0.0000 Cs-134 8.805E-04 0.1896 2.345E-08 0.0000 0.000E+00 0.0000 1.396E-07 0.0000 3.561E-08 0.0000 4.006E-08 0.0000 3.085E-09 0.0000 Cs-137 9.453E-04 0.2036 4.814E-08 0.0000 0.000E+00 0.0000 2.830E-07 0.0001 7.222E-08 0.0000 8.124E-08 0.0000 6.256E-09 0.0000 Ni-63 0.000E+00 0.0000 9.454E-09 0.0000 0.000E+00 0.0000 3.839E-09 0.0000 6.795E-11 0.0000 2.351E-09 0.0000 7.191E-11 0.0000 Sr-90 1.199E-06 0.0003 3.392E-07 0.0001 0.000E+00 0.0000 1.142E-06 0.0002 1.627E-08 0.0000 4.052E-08 0.0000 3.284E-09 0.0000 Total 4.641E-03 0.9994 6.471E-07 0.0001 0.000E+00 0.0000 1.770E-06 0.0004 1.557E-07 0.0000 1.707E-07 0.0000 1.501E-08 0.0000 Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)
As mrem/yr and Fraction of Total Dose At t = 3.000E+00 years Water Dependent Pathways Water Fish Radon Plant Meat Milk All Pathways*
Radio-Nuclide mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract.
Co-60 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 2.814E-03 0.6060 Cs-134 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 8.807E-04 0.1897 Cs-137 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 9.458E-04 0.2037 Ni-63 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.578E-08 0.0000 Sr-90 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 2.740E-06 0.0006 Total 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 4.643E-03 1.0000
- Sum of all water independent and dependent pathways.
RESRAD, Version 7.0 T1/2 Limit = 30 days 12/06/2014 14:01 Page 13 Summary : Zion Surface Soil 0.01 m^2 120614 File : C:\\RESRAD_FAMILY\\RESRAD\\7.0\\USERFILES\\ZION SURFACE SOIL DCGL.RAD Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)
As mrem/yr and Fraction of Total Dose At t = 1.000E+01 years Water Independent Pathways (Inhalation excludes radon)
Ground Inhalation Radon Plant Meat Milk Soil Radio-Nuclide mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract.
Co-60 1.053E-03 0.5580 8.324E-08 0.0000 0.000E+00 0.0000 7.375E-08 0.0000 1.157E-08 0.0000 2.380E-09 0.0000 8.478E-10 0.0000 Cs-134 7.873E-05 0.0417 2.047E-09 0.0000 0.000E+00 0.0000 1.218E-08 0.0000 3.108E-09 0.0000 3.497E-09 0.0000 2.692E-10 0.0000 Cs-137 7.550E-04 0.3999 3.750E-08 0.0000 0.000E+00 0.0000 2.205E-07 0.0001 5.627E-08 0.0000 6.330E-08 0.0000 4.874E-09 0.0000 Ni-63 0.000E+00 0.0000 7.307E-09 0.0000 0.000E+00 0.0000 2.967E-09 0.0000 5.252E-11 0.0000 1.817E-09 0.0000 5.558E-11 0.0000 Sr-90 2.774E-08 0.0000 7.610E-09 0.0000 0.000E+00 0.0000 2.563E-08 0.0000 3.652E-10 0.0000 9.093E-10 0.0000 7.368E-11 0.0000 Total 1.887E-03 0.9997 1.377E-07 0.0001 0.000E+00 0.0000 3.350E-07 0.0002 7.137E-08 0.0000 7.190E-08 0.0000 6.120E-09 0.0000 Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)
As mrem/yr and Fraction of Total Dose At t = 1.000E+01 years Water Dependent Pathways Water Fish Radon Plant Meat Milk All Pathways*
Radio-Nuclide mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract.
Co-60 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.054E-03 0.5581 Cs-134 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 7.876E-05 0.0417 Cs-137 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 7.554E-04 0.4001 Ni-63 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.220E-08 0.0000 Sr-90 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 6.233E-08 0.0000 Total 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.888E-03 1.0000
- Sum of all water independent and dependent pathways.
RESRAD, Version 7.0 T1/2 Limit = 30 days 12/06/2014 14:01 Page 14 Summary : Zion Surface Soil 0.01 m^2 120614 File : C:\\RESRAD_FAMILY\\RESRAD\\7.0\\USERFILES\\ZION SURFACE SOIL DCGL.RAD Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)
As mrem/yr and Fraction of Total Dose At t = 3.000E+01 years Water Independent Pathways (Inhalation excludes radon)
Ground Inhalation Radon Plant Meat Milk Soil Radio-Nuclide mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract.
Co-60 6.159E-05 0.1377 4.566E-09 0.0000 0.000E+00 0.0000 4.046E-09 0.0000 6.348E-10 0.0000 1.306E-10 0.0000 4.650E-11 0.0000 Cs-134 7.708E-08 0.0002 1.856E-12 0.0000 0.000E+00 0.0000 1.105E-11 0.0000 2.820E-12 0.0000 3.172E-12 0.0000 2.442E-13 0.0000 Cs-137 3.853E-04 0.8617 1.770E-08 0.0000 0.000E+00 0.0000 1.041E-07 0.0002 2.656E-08 0.0001 2.988E-08 0.0001 2.300E-09 0.0000 Ni-63 0.000E+00 0.0000 3.370E-09 0.0000 0.000E+00 0.0000 1.369E-09 0.0000 2.423E-11 0.0000 8.382E-10 0.0000 2.564E-11 0.0000 Sr-90 5.742E-13 0.0000 1.424E-13 0.0000 0.000E+00 0.0000 4.797E-13 0.0000 6.835E-15 0.0000 1.702E-14 0.0000 1.379E-15 0.0000 Total 4.470E-04 0.9996 2.563E-08 0.0001 0.000E+00 0.0000 1.095E-07 0.0002 2.722E-08 0.0001 3.085E-08 0.0001 2.372E-09 0.0000 Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)
As mrem/yr and Fraction of Total Dose At t = 3.000E+01 years Water Dependent Pathways Water Fish Radon Plant Meat Milk All Pathways*
Radio-Nuclide mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract.
Co-60 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 6.160E-05 0.1378 Cs-134 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 7.710E-08 0.0002 Cs-137 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 3.855E-04 0.8621 Ni-63 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 5.627E-09 0.0000 Sr-90 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.221E-12 0.0000 Total 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 4.472E-04 1.0000
- Sum of all water independent and dependent pathways.
RESRAD, Version 7.0 T1/2 Limit = 30 days 12/06/2014 14:01 Page 15 Summary : Zion Surface Soil 0.01 m^2 120614 File : C:\\RESRAD_FAMILY\\RESRAD\\7.0\\USERFILES\\ZION SURFACE SOIL DCGL.RAD Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)
As mrem/yr and Fraction of Total Dose At t = 1.000E+02 years Water Independent Pathways (Inhalation excludes radon)
Ground Inhalation Radon Plant Meat Milk Soil Radio-Nuclide mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract.
Co-60 8.720E-18 0.0000 4.247E-22 0.0000 0.000E+00 0.0000 3.784E-18 0.0000 3.701E-18 0.0000 1.050E-18 0.0000 4.325E-24 0.0000 Cs-134 6.357E-27 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 6.633E-27 0.0000 7.240E-27 0.0000 1.279E-26 0.0000 0.000E+00 0.0000 Cs-137 9.000E-14 0.1122 2.917E-18 0.0000 0.000E+00 0.0000 1.724E-13 0.2150 1.908E-13 0.2379 3.370E-13 0.4203 3.791E-19 0.0000 Ni-63 0.000E+00 0.0000 5.132E-19 0.0000 0.000E+00 0.0000 2.096E-15 0.0026 1.784E-16 0.0002 9.371E-15 0.0117 3.904E-21 0.0000 Sr-90 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Total 9.001E-14 0.1122 3.430E-18 0.0000 0.000E+00 0.0000 1.745E-13 0.2177 1.909E-13 0.2381 3.464E-13 0.4320 3.830E-19 0.0000 Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)
As mrem/yr and Fraction of Total Dose At t = 1.000E+02 years Water Dependent Pathways Water Fish Radon Plant Meat Milk All Pathways*
Radio-Nuclide mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract.
Co-60 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.726E-17 0.0000 Cs-134 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 3.302E-26 0.0000 Cs-137 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 7.902E-13 0.9855 Ni-63 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.165E-14 0.0145 Sr-90 2.019E-20 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 9.821E-27 0.0000 8.955E-28 0.0000 1.739E-27 0.0000 2.019E-20 0.0000 Total 2.019E-20 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 9.821E-27 0.0000 8.955E-28 0.0000 1.739E-27 0.0000 8.019E-13 1.0000
- Sum of all water independent and dependent pathways.
RESRAD, Version 7.0 T1/2 Limit = 30 days 12/06/2014 14:01 Page 16 Summary : Zion Surface Soil 0.01 m^2 120614 File : C:\\RESRAD_FAMILY\\RESRAD\\7.0\\USERFILES\\ZION SURFACE SOIL DCGL.RAD Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)
As mrem/yr and Fraction of Total Dose At t = 3.000E+02 years Water Independent Pathways (Inhalation excludes radon)
Ground Inhalation Radon Plant Meat Milk Soil Radio-Nuclide mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract.
Co-60 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Cs-134 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Cs-137 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Ni-63 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Sr-90 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Total 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)
As mrem/yr and Fraction of Total Dose At t = 3.000E+02 years Water Dependent Pathways Water Fish Radon Plant Meat Milk All Pathways*
Radio-Nuclide mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract.
Co-60 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Cs-134 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Cs-137 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Ni-63 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Sr-90 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Total 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000
- Sum of all water independent and dependent pathways.
RESRAD, Version 7.0 T1/2 Limit = 30 days 12/06/2014 14:01 Page 17 Summary : Zion Surface Soil 0.01 m^2 120614 File : C:\\RESRAD_FAMILY\\RESRAD\\7.0\\USERFILES\\ZION SURFACE SOIL DCGL.RAD Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)
As mrem/yr and Fraction of Total Dose At t = 1.000E+03 years Water Independent Pathways (Inhalation excludes radon)
Ground Inhalation Radon Plant Meat Milk Soil Radio-Nuclide mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract.
Co-60 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Cs-134 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Cs-137 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Ni-63 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Sr-90 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Total 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)
As mrem/yr and Fraction of Total Dose At t = 1.000E+03 years Water Dependent Pathways Water Fish Radon Plant Meat Milk All Pathways*
Radio-Nuclide mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract.
Co-60 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Cs-134 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Cs-137 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Ni-63 5.629E-12 1.0000 0.000E+00 0.0000 0.000E+00 0.0000 2.273E-18 0.0000 1.511E-19 0.0000 5.490E-18 0.0000 5.629E-12 1.0000 Sr-90 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Total 5.629E-12 1.0000 0.000E+00 0.0000 0.000E+00 0.0000 2.273E-18 0.0000 1.511E-19 0.0000 5.490E-18 0.0000 5.629E-12 1.0000
- Sum of all water independent and dependent pathways.
RESRAD, Version 7.0 T1/2 Limit = 30 days 12/06/2014 14:01 Page 18 Summary : Zion Surface Soil 0.01 m^2 120614 File : C:\\RESRAD_FAMILY\\RESRAD\\7.0\\USERFILES\\ZION SURFACE SOIL DCGL.RAD Dose/Source Ratios Summed Over All Pathways Parent and Progeny Principal Radionuclide Contributions Indicated Parent Product Thread DSR(j,t) At Time in Years (mrem/yr)/(pCi/g)
(i) (j) Fraction 0.000E+00 1.000E+00 3.000E+00 1.000E+01 3.000E+01 1.000E+02 3.000E+02 1.000E+03 Co-60 Co-60 1.000E+00 4.281E-03 3.723E-03 2.814E-03 1.054E-03 6.160E-05 1.726E-17 0.000E+00 0.000E+00 Cs-134 Cs-134 1.000E+00 2.476E-03 1.754E-03 8.807E-04 7.876E-05 7.710E-08 3.302E-26 0.000E+00 0.000E+00 Cs-137+D Cs-137+D 1.000E+00 1.040E-03 1.008E-03 9.458E-04 7.554E-04 3.855E-04 7.902E-13 0.000E+00 0.000E+00 Ni-63 Ni-63 1.000E+00 1.760E-08 1.697E-08 1.578E-08 1.220E-08 5.627E-09 1.165E-14 0.000E+00 5.629E-12 Sr-90+D Sr-90+D 1.000E+00 1.384E-05 8.070E-06 2.740E-06 6.233E-08 1.221E-12 2.019E-20 0.000E+00 0.000E+00 The DSR includes contributions from associated (half-life 30 days) daughters.
Single Radionuclide Soil Guidelines G(i,t) in pCi/g Basic Radiation Dose Limit = 2.500E+01 mrem/yr Nuclide (i) t= 0.000E+00 1.000E+00 3.000E+00 1.000E+01 3.000E+01 1.000E+02 3.000E+02 1.000E+03 Co-60 5.839E+03 6.715E+03 8.884E+03 2.373E+04 4.058E+05 *1.113E+15 *1.113E+15 *1.113E+15 Cs-134 1.010E+04 1.425E+04 2.839E+04 3.174E+05 3.242E+08 *1.283E+15 *1.283E+15 *1.283E+15 Cs-137 2.403E+04 2.481E+04 2.643E+04 3.310E+04 6.485E+04 3.164E+13 *8.593E+13 *8.593E+13 Ni-63 1.421E+09 1.473E+09 1.584E+09 2.049E+09 4.443E+09 *5.586E+13 *5.586E+13 4.441E+12 Sr-90 1.807E+06 3.098E+06 9.123E+06 4.011E+08 2.047E+13 *1.366E+14 *1.366E+14 *1.366E+14
- At specific activity limit Summed Dose/Source Ratios DSR(i,t) in (mrem/yr)/(pCi/g) and Single Radionuclide Soil Guidelines G(i,t) in pCi/g at tmin = time of minimum single radionuclide soil guideline and at tmax = time of maximum total dose = 0.000E+00 years Nuclide Initial tmin DSR(i,tmin) G(i,tmin) DSR(i,tmax) G(i,tmax)
(i) (pCi/g) (years) (pCi/g) (pCi/g)
Co-60 1.000E+00 0.000E+00 4.281E-03 5.839E+03 4.281E-03 5.839E+03 Cs-134 1.000E+00 0.000E+00 2.476E-03 1.010E+04 2.476E-03 1.010E+04 Cs-137 1.000E+00 0.000E+00 1.040E-03 2.403E+04 1.040E-03 2.403E+04 Ni-63 1.000E+00 0.000E+00 1.760E-08 1.421E+09 1.760E-08 1.421E+09 Sr-90 1.000E+00 0.000E+00 1.384E-05 1.807E+06 1.384E-05 1.807E+06
RESRAD, Version 7.0 T1/2 Limit = 30 days 12/06/2014 14:01 Page 19 Summary : Zion Surface Soil 0.01 m^2 120614 File : C:\\RESRAD_FAMILY\\RESRAD\\7.0\\USERFILES\\ZION SURFACE SOIL DCGL.RAD Individual Nuclide Dose Summed Over All Pathways Parent Nuclide and Branch Fraction Indicated Nuclide Parent THF(i) DOSE(j,t), mrem/yr (j) (i) t= 0.000E+00 1.000E+00 3.000E+00 1.000E+01 3.000E+01 1.000E+02 3.000E+02 1.000E+03 Co-60 Co-60 1.000E+00 4.281E-03 3.723E-03 2.814E-03 1.054E-03 6.160E-05 1.726E-17 0.000E+00 0.000E+00 Cs-134 Cs-134 1.000E+00 2.476E-03 1.754E-03 8.807E-04 7.876E-05 7.710E-08 3.302E-26 0.000E+00 0.000E+00 Cs-137 Cs-137 1.000E+00 1.040E-03 1.008E-03 9.458E-04 7.554E-04 3.855E-04 7.902E-13 0.000E+00 0.000E+00 Ni-63 Ni-63 1.000E+00 1.760E-08 1.697E-08 1.578E-08 1.220E-08 5.627E-09 1.165E-14 0.000E+00 5.629E-12 Sr-90 Sr-90 1.000E+00 1.384E-05 8.070E-06 2.740E-06 6.233E-08 1.221E-12 2.019E-20 0.000E+00 0.000E+00 THF(i) is the thread fraction of the parent nuclide.
Individual Nuclide Soil Concentration Parent Nuclide and Branch Fraction Indicated Nuclide Parent THF(i) S(j,t), pCi/g (j) (i) t= 0.000E+00 1.000E+00 3.000E+00 1.000E+01 3.000E+01 1.000E+02 3.000E+02 1.000E+03 Co-60 Co-60 1.000E+00 1.000E+00 8.759E-01 6.720E-01 2.658E-01 1.877E-02 1.758E-06 5.429E-18 0.000E+00 Cs-134 Cs-134 1.000E+00 1.000E+00 7.135E-01 3.632E-01 3.418E-02 3.991E-05 2.173E-15 9.809E-45 0.000E+00 Cs-137 Cs-137 1.000E+00 1.000E+00 9.754E-01 9.280E-01 7.795E-01 4.737E-01 8.286E-02 5.690E-04 1.527E-11 Ni-63 Ni-63 1.000E+00 1.000E+00 9.743E-01 9.248E-01 7.707E-01 4.578E-01 7.395E-02 4.044E-04 4.889E-12 Sr-90 Sr-90 1.000E+00 1.000E+00 5.876E-01 2.029E-01 4.908E-03 1.182E-07 8.114E-24 0.000E+00 0.000E+00 THF(i) is the thread fraction of the parent nuclide.
RESCALC.EXE execution time = 1.47 seconds