ML21067A214
| ML21067A214 | |
| Person / Time | |
|---|---|
| Site: | Zion File:ZionSolutions icon.png |
| Issue date: | 02/10/2021 |
| From: | Yetter R ZionSolutions |
| To: | Office of Nuclear Material Safety and Safeguards |
| Shared Package | |
| ML21067A225 | List:
|
| References | |
| ZS-2021-0001 | |
| Download: ML21067A214 (141) | |
Text
ZION STATION RESTORATION PROJECT FINAL STATUS SURVEY RELEASE RECORD PENETRATIONS SURVEY UNITS 01112, 02112, 05120 Revision 1
- =-
= ZIONSOLUTIONSLLC-An EnergySolutions Company
FSS RELEASE RECORD, REV 1 PENETRATIONS SURVEY UNITS 01112, 02112 and 05120
[2]
PREPARED BY / DATE:
Robert Yetter III Final Status Survey Specialist REVIEWED BY / DATE:
Robert Yetter Director, Radiological Site Closure APPROVED BY / DATE:
Sarah Roberts Vice President, Radiological Programs
~
= ZIONSOLUTJONSLLc-
~ ~
Nov 11 2020 11 :02 AM v1 /~
1 Robert F. Yetter III cos13n Robert F. Yetter 9lo..D.eJd 5. C/Jelle!t Nov 11 2020 12:26 PM cosi3n Sarah Roberts Sarah Roberts Nov ll 2020 1:03 PM cosign
FSS RELEASE RECORD, REV 1 PENETRATIONS SURVEY UNITS 01112, 02112 and 05120
[3]
TABLE OF CONTENTS
- 1.
EXECUTIVE
SUMMARY
....................................................................................................6
- 2.
SURVEY UNIT DESCRIPTION..........................................................................................8
- 3.
CLASSIFICATION BASIS.................................................................................................14
- 4.
DATA QUALITY OBJECTIVES (DQO)..........................................................................17
- 5.
SURVEY DESIGN...............................................................................................................21
- 6.
SURVEY IMPLEMENTATION........................................................................................29
- 7.
SURVEY RESULTS............................................................................................................31
- 8.
QUALITY CONTROL........................................................................................................46
- 9.
INVESTIGATIONS AND RESULTS................................................................................47
- 10. REMEDIATION AND RESULTS......................................................................................47
- 11. CHANGES FROM THE FINAL STATUS SURVEY PLAN..........................................47
- 12. DATA QUALITY ASSESSMENT (DQA).........................................................................47
- 13. ANOMALIES.......................................................................................................................48
- 14. CONCLUSION.....................................................................................................................48
- 15. REFERENCES.....................................................................................................................49
- 16. ATTACHMENTS.................................................................................................................50 ATTACHMENT 1................................................................................................................51 ATTACHMENT 2................................................................................................................63 ATTACHMENT 3..............................................................................................................105 ATTACHMENT 4..............................................................................................................131 ATTACHMENT 5..............................................................................................................135
~
=ZIONSOLUTIONSuc-AnEr,e,gy~Compaoy
FSS RELEASE RECORD, REV 1 PENETRATIONS SURVEY UNITS 01112, 02112 and 05120
[4]
LIST OF TABLES Table 1 - Unit 1 Containment Building Penetrations.................................................................... 10 Table 2 - Unit 2 Containment Building Penetrations.................................................................... 12 Table 3 - Auxiliary Building Penetrations................................................................................... 14 Table 4 - Dose Significant Radionuclides and Mixture............................................................... 18 Table 5 - Base Case DCGLs for Penetrations.............................................................................. 19 Table 6 - Operational DCGLs for Penetrations............................................................................ 20 Table 7 - Most-Limiting Base Case DCGLs for Penetrations..................................................... 21 Table 8 - Most-Limiting Operational DCGLs for Penetrations................................................... 21 Table 9 - Containment and Auxiliary Building Surrogate Ratios................................................ 24 Table 10 - Penetrations FSS Instrumentation and Action Levels................................................. 25 Table 11 - Investigation Levels.................................................................................................... 26 Table 12 - Systematic Static Locations for Hand-Held Surveys in Unit 1 Containment Penetrations................................................................................................................................... 27 Table 13 - Systematic Static Locations for Hand-Held Surveys in Unit 2 Containment Penetrations................................................................................................................................... 28 Table 14 - Systematic Static Locations for Hand-Held Surveys in Auxiliary Building Penetrations................................................................................................................................... 29 Table 15 - Most Limiting OpDCGLs for Structures from LTP Chapter 5, Table 5-4................. 32 Table 16 - Unit 1 Containment Penetrations Summary............................................................... 34 Table 17 - Summary of Unit 1 Containment Penetrations FSS Statistics.................................... 36 Table 18 - Unit 2 Containment Penetrations Summary............................................................... 39 Table 19 - Summary of Unit 2 Containment Penetrations FSS Statistics.................................... 41 Table 20 - Auxiliary Building Penetrations Summary................................................................. 43 Table 21 - Summary of Auxiliary Building Penetrations FSS Statistics..................................... 44 Table 22 - Summary of Turbine Building Penetrations FSS Statistics........................................ 46 Table 23 - Summary of Mean OpSOFPN for Penetration FSS..................................................... 48 Table 24 - Summary of Mean BcSOFPN and Mean Dose for Penetration FSS............................ 49 LIST OF FIGURES Figure 1 - Spent Fuel Transfer Tube removed leaving 8 x 8 Access........................................... 9 Figure 2 - Recirculating Sump Suction Penetrations Grouted...................................................... 22 Figure 3 - Cavity Flood Sump Suction Penetrations Grouted...................................................... 23
~
=ZIONSOLUTIONSuc-AnEr,e,gy~Compaoy
FSS RELEASE RECORD, REV 1 PENETRATIONS SURVEY UNITS 01112, 02112 and 05120
[5]
LIST OF ACRONYMS AND ABBREVIATIONS ALARA As Low As Reasonably Achievable AMCG Average Member of the Critical Group BFM Basement Fill Model DQA Data Quality Assessment DQO Data Quality Objective DCGL Derived Concentration Guideline Level EMC Elevated Measurement Comparison FOV Field-of-View FSS Final Status Survey IC Insignificant Contributor ID Internal Diameter LTP License Termination Plan MARSSIM Multi-Agency Radiation Survey and Site Investigation Manual MDC Minimum Detectable Concentration NaI Sodium Iodide QAPP Quality Assurance Project Plan OpDCGL Operational Derived Concentration Guideline Level QC Quality Control RE Radiological Engineer ROC Radionuclides of Concern SOF Sum of Fractions TSD Technical Support Document ZNPS Zion Nuclear Power Station ZSRP Zion Station Restoration Project
~
=ZIONSOLUTIONSuc-AnEr,e,gy~Compaoy
FSS RELEASE RECORD, REV 1 PENETRATIONS SURVEY UNITS 01112, 02112 and 05120
[6]
- 1.
EXECUTIVE
SUMMARY
This Final Status Survey (FSS) Release Record for survey unit 01112, Unit 1 Containment Building Penetrations, survey unit 02112, Unit 2 Containment Building Penetrations and survey unit 05120, Auxiliary Building Penetrations, has been generated for the Zion Station Restoration Project (ZSRP) in accordance with ZionSolutions procedure ZS-LT-300-001-005, Final Status Survey Data Reporting (Reference 1) and satisfies the requirements of Section 5.11 of the Zion Station Restoration Project License Termination Plan (LTP) (Reference 2).
Three (3) FSS sample plans (S1-01112A-F #1, S1-01112A-F #2, S1-01112A-F #3) were developed to perform FSS in survey unit 01112, three (3) FSS sample plans (S1-02112A-F #1, S1-02112A-F #2, S1-02112A-F #3) were developed to perform FSS in survey unit 02112 and two (2) FSS sample plans (S1-05120A-F #1 and S1-05120A-F #2) were developed to perform FSS in survey unit 05120 in accordance with ZionSolutions procedure ZS-LT-300-001-001, Final Status Survey Package Development (Reference 3), the ZSRP LTP, and with guidance from NUREG-1575, Multi-Agency Radiation Survey and Site Investigation Manual (MARSSIM) (Reference 4).
FSS was performed to demonstrate that the concentrations of residual radioactivity on the interior surfaces of the penetrations were equal to or below site-specific Derived Concentration Guideline Levels (DCGL) corresponding to the dose criterion in 10 CFR 20.1402. Initially, the penetrations were segregated and classified in accordance with the type of system and system use. However, in a conservative measure to ensure that all accessible surfaces within each end-state penetration would be subjected to FSS, the classification of all penetrations was changed to Class 1.
Two (2) different survey approaches were used for FSS depending on the diameter, length and access to the penetrations. FSS measurements applicable to penetrations with an internal diameter (ID) less than 12 inches consisted of a static measurement taken at 1-foot intervals inside the penetration using a sodium iodide (NaI), conservatively assuming a Field-of-View (FOV) of 1-foot for each measurement. This FOV provided 100% areal coverage of the accessible internal surfaces of the penetration.
FSS measurements acquired in penetrations with an ID greater than 12 inches consisted of a 100% scan with a hand-held beta-gamma detector of the interior surface area of the penetration, at least one (1) 1-minute static gross beta-gamma measurement at a systematic location based on a triangular grid, and a 1-minute static measurement at the location of the highest observed scan result in each penetration.
~
=ZIONSOLUTIONSuc-AnEr,e,gy~Compaoy
FSS RELEASE RECORD, REV 1 PENETRATIONS SURVEY UNITS 01112, 02112 and 05120
[7]
LTP, Section 6.4.5 states, The dose from penetrations is summed with the dose from the wall and floor surfaces of both basements that the penetration interface. Consequently, the most limiting DCGL for each ROC from the Containment, Auxiliary Building and Turbine Building Operational DCGLs (OpDCGL) and Base Case DCGLs (BcDCGL) were used to compare against the measurements taken within the penetrations, regardless of location.
Seven hundred and seventy-nine (779) measurements were obtained. Evaluation of the data shows that none of the ROC concentration values exceed the OpDCGLPN or any investigational levels in 734 of the 779 measurements taken. Forty-five (45) measurements exceeded the most-limiting OpDCGLPN but were less than the most-limiting BcDCGLPN.
The Operational SOF (OpSOF), based on the OpDCGL, for an individual systematic or judgmental measurement may exceed one without remediation as long as the survey unit passes the Sign Test, and the mean OpSOF for the survey unit does not exceed one. The mean OpSOFPN for Unit 1 Containment was 0.661, for Unit 2 Containment was 0.142, for the Auxiliary Building was 0.405 and for the Turbine Building was 0.021.
LTP, Section 5.5.5 requires that the dose from elevated measurements be added to the mean dose for the survey unit affected. Forty-five (45) measurements exceeded the OpDCGLPN in penetrations that interfaced between the Containment and the Auxiliary Building.
Consequently, the mean BcSOF was adjusted to account for the identified elevated measurements. The mean BcSOF for Unit 1 Containment was adjusted by a value of 0.053, and the mean BcSOF for the Auxiliary Building was adjusted by a value of 0.007. These values were then added to the mean BcSOF of the Unit 1 Containment penetration (i.e.,
0.048) and the mean BcSOF of the Auxiliary Building (i.e., 0.030). Table 24 presents the adjusted mean BcSOFPN for each penetration survey unit which accounts for the elevated measurements and the derived dose for each.
LTP, Section 6.4.5 requires that the dose from a penetration be added to each basement that the penetration interfaces with. The values listed in Table 24 will be added to each basement as applicable. The mean BcSOFPN for the Unit 1 Containment was 0.101, for the Unit 2 Containment was 0.010, for the Auxiliary Building was 0.037 and for the Turbine Building was 0.002.
~
=ZIONSOLUTIONSuc-AnEr,e,gy~Compaoy
FSS RELEASE RECORD, REV 1 PENETRATIONS SURVEY UNITS 01112, 02112 and 05120
[8]
- 2.
SURVEY UNIT DESCRIPTION Penetrations are defined in LTP, Section 5.5.5: A penetration is defined as a pipe (or remaining pipe sleeve, if the pipe is removed, or concrete, if the pipe and pipe sleeve is removed) that runs through a concrete wall and/or floor, between two buildings, and is open at the wall or floor surface of each building. A penetration could also be a pipe that runs through a concrete wall and/or floor and opens to a building on one end and the outside ground on the other end.
A summary of the original End State lengths and surface areas for the Unit 1 and Unit 2 Containment Buildings, the Auxiliary Building and Turbine Building penetrations are presented in Attachment F of ZionSolutions Technical Support Document (TSD)14-016, Description of Embedded Piping, Penetrations, and Buried Pipe to Remain in Zion End State (Reference 5). Penetration locations are shown in Attachment 1 of this Release Record.
In accordance with LTP, Section 5.5.5, penetration survey units have total surface areas that are less than the area of the wall/floor surface survey unit that the penetrations interface. To eliminate the potential for activity levels in penetrations that could lead to releases greater than the adjacent basement walls and floors, the following remediation and grouting action levels were applied to measurements of surface activity in penetrations.
If maximum activity exceeded the BcDCGLPN from LTP, Table 5-13 (BcSOF >1), then remediation was performed.
If the maximum activity in a penetration exceeded the most limiting OpDCGLB from LTP, Table 5-4 of the two basements where a penetrations interface (OpSOF>1), but is below the BcDCGLPN from LTP, Table 5-13, then the penetration was remediated or grouted.
If a penetration was remediated and the maximum activity continued to exceed the most limiting OpDCGLB from LTP, Table 5-4 of the two basements where a penetrations interface (OpSOF>1), but was less than the OpDCGLPN (LTP, Table 5-14), then the penetration was grouted.
If the maximum activity was below the surface OpDCGLB from LTP, Table 5-4, then grouting of the penetration was not required.
Unit 1 Containment The Unit 1 Containment Building Penetrations survey unit consisted of sixty-one (61) penetrations ranging from six (6) inches to fifty (50) inches in diameter.
The End State condition depicted in TSD 14-016 was altered due to decommissioning activities and observations made during survey design and walkdown. Eight (8) penetrations listed for Unit 1 Containment in TSD 14-016 are above the basement End
~
=ZIONSOLUTIONSuc-AnEr,e,gy~Compaoy
FSS RELEASE RECORD, REV 1 PENETRATIONS SURVEY UNITS 01112, 02112 and 05120
[9]
State 588-foot elevation and were not included as part of the FSS. Five (5) penetrations residing in the Recirculating Water Sump and Cavity Flood Sump had an original End State of pipe in sleeve. The piping within the penetrations was removed during decommissioning, leaving only a larger diameter open sleeve for each of the five penetrations. Additionally, a section of wall housing one (1) penetration (the Fuel Transfer Tube) was demolished to allow access to the building (See Figure 1).
Figure 1 - Spent Fuel Transfer Tube removed leaving 8 x 8 Access The list and descriptions of the penetrations is provided in Table 1. Visual depictions of the Unit 1 Containment Building Penetrations are provided in Attachment 1.
~
=ZIONSOLUTIONSuc-AnEr,e,gy~Compaoy
FSS RELEASE RECORD, REV 1 PENETRATIONS SURVEY UNITS 01112, 02112 and 05120
[10]
Table 1 - Unit 1 Containment Building Penetrations Penetration No.
Description Initial Classification Diameter Surface Area Length Length (in)
(m2)
(ft)
(m)
P001 Fire Protection 3
10 1.22 5
1.52 P003 Spare 2
6 0.73 5
1.52 P004 Boron Injection Tank to Cold Legs 1
8 0.97 5
1.52 P005 Main Steam 2
50 4.86 4
1.22 P006 Main Steam 2
50 4.86 4
1.22 P007 Main Steam 2
50 4.86 4
1.22 P008 Main Steam 2
50 4.86 4
1.22 P009 Feedwater 2
32 3.11 4
1.22 P010 Feedwater 2
32 3.11 4
1.22 P011 Feedwater 2
32 3.11 4
1.22 P012 Feedwater 2
32 3.11 4
1.22 P017 Reactor Coolant 2 Loop to RHR Pumps 1
28 3.41 5
1.52 P018 Cavity Fill Pump 1A Discharge 1
18 2.19 5
1.52 P019 Reactor Coolant 1 to RHR Pumps 2
12 1.46 5
1.52 P020 Cavity Fill Pump 1B Discharge 1
18 2.19 5
1.52 P021 Spare 2
28 3.41 5
1.52 P022 RHR to RC Loop Cold Legs 1
28 3.41 5
1.52 P023 RHR to RC Loop Cold Legs 2
12 1.46 5
1.52 P035 Recirculating Sump Suction 1
23 28.53 51 15.55 P036 Cavity Flood Sump Suction 1
23 28.53 51 15.55 P037 Cavity Flood Sump Suction 1
23 28.53 51 15.55 P042 CTMT Sump Discharge to Drain Tank 1
6 0.73 5
1.52 P043 RC Drain Pump to Hold-Up Tank 1
8 0.97 5
1.52 P050 Spare 2
10 1.22 5
1.52 P054 Containment Pressure 2
6 0.73 5
1.52 P056 Filtered Vents 2
8 0.97 5
1.52 P064 Spare 2
10 1.22 5
1.52 P066 RC Pump Seal Water Supply Lines 2
14 1.7 5
1.52 P067 Spare 2
18 2.19 5
1.52 P068 Aux Feedwater to Steam Gen 1C 2
14 1.7 5
1.52 P069 Aux Feedwater to Steam Gen 1A 2
14 1.7 5
1.52 P070 Cavity Drain to Purification Pump 1
14 1.7 5
1.52 P073 Spare 2
18 2.19 5
1.52 P074 Aux Feedwater to Steam Gen 1D 2
14 1.7 5
1.52 P081 Non-Filtered Vents 2
8 0.97 5
1.52 P086 RC Hot Leg Samples 2
10 1.22 5
1.52 P087 Spare 2
10 1.22 5
1.52 P088 Heating System Hot Water Supply 2
12 1.46 5
1.52 P089 Heating System Hot Water Return 2
12 1.46 5
1.52 P090 Spare 2
28 3.41 5
1.52 P091 Blowdown Steam Generator 1A 2
16 1.56 4
1.22 P092 Blowdown Steam Generator 1A 2
16 1.56 4
1.22 P093 Blowdown Steam Generator 1C 2
16 1.56 4
1.22 P094 Blowdown Steam Generator 1C 2
16 1.56 4
1.22 P095 Blowdown Steam Generator 1A 2
14 1.36 4
1.22
~
=ZIONSOLUTIONSuc-AnEr,e,gy~Compaoy
FSS RELEASE RECORD, REV 1 PENETRATIONS SURVEY UNITS 01112, 02112 and 05120
[11]
Table 1 (continued) - Unit 1 Containment Building Penetrations Penetration No.
Description Initial Classification Diameter Surface Area Length Length (in)
(m2)
(ft)
(m)
P096 Blowdown Steam Generator 1C 2
14 1.36 4
1.22 P097 Blowdown Steam Generator 1D 2
14 1.36 4
1.22 P098 Blowdown Steam Generator 1B 2
14 1.36 4
1.22 P103 Spare 2
8 0.97 5
1.52 P104 SIM to Aux F.S. Pumps 1
24 2.92 5
1.52 P105 RHR to RC Loop Hot Legs 1
18 2.19 5
1.52 P112 Steam Generator Blowdown Sample 2
16 1.56 4
1.22 P113 Steam Generator Blowdown Sample 2
16 1.56 4
1.22 P115 Blowdown (Steam Generator 1D) 2 16 1.56 4
1.22 P116 Blowdown (Steam Generator 1D) 2 16 1.56 4
1.22 P117 Blowdown (Steam Generator 1B) 2 16 1.56 4
1.22 P118 Blowdown (Steam Generator 1B) 2 16 1.56 4
1.22 P123 Recirculating Sump Suction 1
23 29.09 52 15.85 P124 Recirculating Sump Suction 1
23 29.09 52 15.85 P127 Steam to Aux FW Pumps 2
16 1.56 4
1.22 P128 Steam to Aux FW Pumps 2
16 1.56 4
1.22 Penetrations P005, P006, P007, P008. P009, P010, P011, P012, P091, P092, P093, P094, P095, P096, P097, P098, P112, P113, P115, P116, P117, P118, P127 and P128 interfaced between the Unit 1 Containment and the Turbine Building, through the Unit 1 East and West Steam Tunnel Valve Houses. All other penetrations interfaced between Unit 1 Containment and the Auxiliary Building.
Unit 2 Containment The Unit 2 Containment Building Penetrations survey unit consisted of sixty-one (61) penetrations ranging from six (6) inches to fifty (50) inches in diameter.
As with Unit 1 Containment, the End State condition for Unit 2 Containment depicted in TSD 14-016 was altered due to D&D activities and observations made during survey design and walk-down. Eight (8) penetrations listed for Unit 2 Containment in TSD 14-016 are above the basement End State 588-foot elevation and were not included as part of the FSS. Five (5) penetrations residing in the Recirculating Water Sump and Cavity Flood Sump had an original End State of pipe in sleeve. The piping within the penetrations was removed during decommissioning, leaving only a larger diameter open sleeve for each of the five penetrations. Additionally, a section of wall housing one (1) penetration (the Fuel Transfer Tube) was demolished to allow access to the building (similar to depiction of Unit 1 in Figure 1).
The list and descriptions of the Unit 2 Containment penetrations is provided in Table 2.
Visual depictions of the Unit 2 Containment Building Penetrations are provided in.
~
=ZIONSOLUTIONSuc-AnEr,e,gy~Compaoy
FSS RELEASE RECORD, REV 1 PENETRATIONS SURVEY UNITS 01112, 02112 and 05120
[12]
Table 2 - Unit 2 Containment Building Penetrations Penetration No.
Description Initial Classification Diameter Surface Area Length Length (in)
(m2)
(ft)
(m)
P201 Fire Protection 3
10 1.22 5
1.47 P203 Spare 2
6 0.73 5
1.47 P204 Boron Injection Tank to Cold Legs 1
8 0.97 5
1.47 P205 Main Steam 2
50 4.86 4
1.22 P206 Main Steam 2
50 4.86 4
1.22 P207 Main Steam 2
50 4.86 4
1.22 P208 Main Steam 2
50 4.86 4
1.22 P209 Feedwater 2
32 3.11 4
1.22 P210 Feedwater 2
32 3.11 4
1.22 P211 Feedwater 2
32 3.11 4
1.22 P212 Feedwater 2
32 3.11 4
1.22 P217 Reactor Coolant to RHR Pumps 1
28 3.41 5
1.47 P218 Cavity Fill Pump 1A Discharge 1
18 2.19 5
1.47 P219 Component Cooling Water Supply 2
12 1.46 5
1.47 P220 Cavity Fill Pump 1B Discharge 1
18 2.19 5
1.47 P221 Spare 2
28 3.41 5
1.47 P222 RHR Exchanger to RC Loop Cold Legs 1
28 3.41 5
1.47 P223 RC Pumps to Cooling Pump Suction 2
12 1.46 5
1.47 P235 Recirculating Sump Suction 1
23 28.53 51 15.6 P236 Cavity Flood Sump Suction 1
23 28.53 51 15.47 P237 Cavity Flood Sump Suction 1
23 28.53 51 15.49 P242 Sump Discharge to Floor Drain Tank 1
6 0.73 5
1.47 P243 RC Drain Pump to Hold-Up Tank 1
8 0.97 5
1.47 P250 Spare 2
10 1.22 5
1.47 P254 Containment Pressure 2
6 0.73 5
1.47 P256 Filtered Vents 2
8 0.97 5
1.47 P264 Spare 2
8 0.97 5
1.47 P266 RC Pump Seal Water Supply Lines 2
14 1.7 5
1.47 P267 Spare 2
18 2.19 5
1.47 P268 Aux Feedwater to Steam Gen 1C 2
14 1.7 5
1.47 P269 Aux Feedwater to Steam Gen 1A 2
14 1.7 5
1.47 P270 Cavity Drain to Purification Pump 1
14 1.7 5
1.47 P273 Spare 2
18 2.19 5
1.47 P274 Aux Feedwater to Steam Gen 1D 2
14 1.7 5
1.47 P281 Non-Filtered Vents 2
8 0.97 5
1.47 P286 RC Hot Leg Samples 2
10 1.22 5
1.47 P287 Spare 2
10 1.22 5
1.47 P288 Heating System Hot Water Supply 2
12 1.46 5
1.47 P289 Heating System Hot Water Return 2
12 1.46 5
1.47 P290 Spare 2
28 3.41 5
1.47 P291 Blowdown Steam Generator 1A 2
16 1.56 4
1.22 P292 Blowdown Steam Generator 1A 2
16 1.56 4
1.22 P293 Blowdown Steam Generator 1C 2
16 1.56 4
1.22 P294 Blowdown Steam Generator 1C 2
16 1.56 4
1.22 P295 Blowdown Steam Generator 1A 2
14 1.36 4
1.22
~
=ZIONSOLUTIONSuc-AnEr,e,gy~Compaoy
FSS RELEASE RECORD, REV 1 PENETRATIONS SURVEY UNITS 01112, 02112 and 05120
[13]
Table 2 (continued) - Unit 2 Containment Building Penetrations Penetration No.
Description Initial Classification Diameter Surface Area Length Length (in)
(m2)
(ft)
(m)
P296 Blowdown Steam Generator 1C 2
14 1.36 4
1.22 P297 Blowdown Steam Generator 1D 2
14 1.36 4
1.22 P298 Blowdown Steam Generator 1B 2
14 1.36 4
1.22 P303 Spare 2
8 0.97 5
1.47 P304 SIM to Aux F.S. Pumps 1
24 2.92 5
1.47 P305 RHR to RC Loop Hot Legs 1
18 2.19 5
1.47 P312 Steam Generator Blowdown Sample 2
16 1.56 4
1.22 P313 Steam Generator Blowdown Sample 2
16 1.56 4
1.22 P315 Blowdown (Steam Generator 1D) 2 16 1.56 4
1.22 P316 Blowdown (Steam Generator 1D) 2 16 1.56 4
1.22 P317 Blowdown (Steam Generator 1B) 2 16 1.56 4
1.22 P318 Blowdown (Steam Generator 1B) 2 16 1.56 4
1.22 P323 Recirculating Sump Suction 1
23 29.09 52 15.85 P324 Recirculating Sump Suction 1
23 29.65 53 16.1 P327 Steam to Aux FW Pumps 2
16 1.56 4
1.22 P328 Steam to Aux FW Pumps 2
16 1.56 4
1.22 Penetration numbers P205, P206, P207, P208, P209, P210, P211, P212, P291, P292, P293, P294, P295, P296, P297, P298, P312, P313, P315, P316, P317, P318, P327 and P328 interfaced between the Unit 2 Containment and the Turbine Building, through the Unit 2 East and West Steam Tunnel Valve Houses. All other penetrations interfaced between Unit 2 Containment and the Auxiliary Building.
The Auxiliary Building The Auxiliary Building penetrations survey unit consists of one-hundred and forty-four (144) penetrations that access the Auxiliary Building between the 542-foot, 560-foot and the 579-foot elevations. One-hundred twenty-two (122) of the 144 penetrations are identified as being both an Auxiliary Building and Containment Building penetration.
The remaining twenty-two (22) penetrations that access the Auxiliary Building between the 542, 560 and the 579-foot elevations, but do not access the Containments, are A001-A025. These penetrations interface between the Auxiliary Building and the Turbine Building primarily through the G wall and through the north and south walls into the Unit 1 and Unit 2 Steam Tunnels.
~
=ZIONSOLUTIONSuc-AnEr,e,gy~Compaoy
FSS RELEASE RECORD, REV 1 PENETRATIONS SURVEY UNITS 01112, 02112 and 05120
[14]
Table 3 - Auxiliary Building Penetrations Penetration No.
Description Initial Classification Diameter Surface Area Length Length (in)
(m2)
(ft)
(m)
A001 Service Water 3
22 1.65 3
0.91 A002 Feedwater 2
4 0.29 3
0.91 A003 Secondary Sample 2
2 0.15 3
0.91 A004 Service Water 3
22 1.65 3
0.91 A005 Feedwater 2
4 0.29 3
0.91 A007 Vents and Drains 2
4 0.29 3
0.91 A008 Vents and Drains 2
4 0.29 3
0.91 A009 Waste Disposal 1
3 0.22 3
0.91 A010 Service Water 3
10 0.73 3
0.91 A011 Waste Disposal 1
2 0.15 3
0.91 A012 Chemical Addition 3
3 0.22 3
0.91 A013 Primary Water 3
4 0.29 3
0.91 A014 Service Water 3
18 1.37 3
0.91 A015 Waste Disposal 1
6 0.44 3
0.91 A017 Fire Protection 3
10 0.73 3
0.91 A019 Primary Water 3
4 0.22 3
0.91 A020 Vacuum Control 3
4 0.22 3
0.91 A021 Demin Water 3
4 0.22 3
0.91 A022 Primary Water 3
4 0.29 3
0.91 A023 Waste Disposal 1
6 0.44 3
0.91 A024 Condensate 3
16 1.23 3
0.91 A025 Service Water 3
34 2.52 3
0.91
- 3.
CLASSIFICATION BASIS Survey units 01112, 02112 and 05120 were classified in accordance with ZionSolutions procedure ZS-LT-300-001-002, Survey Unit Classification (Reference 6).
The Containment and Auxiliary Building Penetrations were initially classified as Class 1, Class 2, or Class 3, based on historical assessment, exposure to radioactive materials and system use. As a conservative measure, the classifications of all penetrations were changed to Class 1. Consequently, sufficient measurements were taken in all penetrations to ensure 100% areal coverage of all accessible internal surfaces within the penetrations.
Containment Buildings The Unit 1 and Unit 2 Containment Buildings housed the Unit 1 and Unit 2 Reactor Vessels, Steam Generators, and Pressurizers. In addition, the Containments also housed numerous systems containing primary coolant as well as radioactively contaminated support systems. System leakage and maintenance activities over the operating life of both reactors resulted in the radiological contamination of most of the interior surfaces of the structures. Some components, equipment, structural steel and concrete became radioactive due to neutron activation. Based on the design basis of the buildings and the operating
~
=ZIONSOLUTIONSuc-AnEr,e,gy~Compaoy
FSS RELEASE RECORD, REV 1 PENETRATIONS SURVEY UNITS 01112, 02112 and 05120
[15]
history, all internal survey units in the Unit 1 and Unit 2 Containment Buildings were given an initial classification of Class 1 in accordance with the Zion Station Historical Site Assessment (HSA) (Reference 7).
The Unit 1 and Unit 2 Containment Penetrations were building to building pipe pathways for various primary and secondary systems. The location of the penetrations, their function, and the operational history of the Containments supported the initial classifications.
From June of 2012 through January of 2013, site characterization was performed in Unit 1 and Unit 2 Containment. The results of the site characterization surveys performed from 2010 to 2013 are documented in ZionSolutions TSD 14-028, Radiological Characterization Report (Reference 8) and in Chapter 2 of the LTP. During the time that initial characterization was performed, all radioactive systems and components were still located inside Containment. Consequently, ambient radiation dose rates inside the Containment prohibited the direct assessment of penetrations or system interior surfaces by scanning or direct measurement.
On November 3, 2016, the last routine surveys were conducted in Unit 1 Containment, before heavy demolition started and access was no longer possible. Surveys 2016-2053 and 2016-1988, conducted in the Outer Missile Barrier (OMB) area of Unit 1, showed a maximum contamination level of 20,000 disintegrations per minute (dpm)/100cm2 and that the maximum dose rate was 5.0 mR/hr. Survey 2016-3470, conducted in the Inner Missile Barrier (IMB) area of Unit 1, showed a maximum loose contamination level of 8,000 dpm/100cm2 and a maximum dose rate of 7.0 mR/hr.
On July 20, 2016, the last routine surveys were conducted in Unit 2 Containment, before heavy demolition started and access was no longer possible. Survey 2016-2226, conducted in the OMB area of Unit 2, showed that all smears were less than 1,000 dpm/100 cm2 and that the maximum dose rate was 1.5 mR/hr. Survey 2016-2224, conducted in the IMB area of Unit 2, showed a maximum loose contamination level of 6,400 dpm/100 cm2 and a maximum dose rate of 5.1 mR/hr.
Auxiliary Building The Auxiliary Building housed numerous systems containing radioactively contaminated support systems. System leakage and maintenance activities over the operating life of the reactor resulted in the radiological contamination of most of the interior surfaces of the structures. Based on the building design basis and the operating history, all internal survey units in Auxiliary Building were assigned an initial classification of Class 1 in accordance with the HSA.
The Auxiliary Building penetrations housed numerous systems including the following:
Service and primary water,
~
=ZIONSOLUTIONSuc-AnEr,e,gy~Compaoy
FSS RELEASE RECORD, REV 1 PENETRATIONS SURVEY UNITS 01112, 02112 and 05120
[16]
Feed and demineralizer water, Fire protection, Vent and drain, Secondary sample, Waste disposal, Chemical addition, Vacuum control, and Condensate.
The location of the penetrations, their function, and the operational history of the Auxiliary Building to support the initial classifications are described in TSD 14-016.
ZionSolutions TSD 14-013 documents seventeen (17) concrete core samples taken from the floors and three (3) cores from the walls of the Auxiliary Building that were obtained for analysis. The on-site gamma spectroscopy results for the sectioned cores from the 542-foot elevation initial characterization may be found in TSD 14-013. All radioactive systems and components were still located inside the building; consequently, ambient radiation dose rates inside the Auxiliary Building prohibited the direct assessment of penetrations or system interior surfaces by scanning or direct measurement.
Summary An RE performed a visual inspection and walk-down of the Unit 2 Containment survey units on December 12, 2017, a visual inspection and walk-down of the Unit 1 Containment survey units on February 27, 2018, and, as part of the survey unit turnover process, a visual inspection and walk-down of the Auxiliary Building on March 27, 2018. The purpose of the walk-downs were to assess the physical condition of each of the survey units, evaluate access points and travel paths and identify potentially hazardous conditions. A final classification assessment was performed for each survey unit in accordance with procedure ZS-LT-300-001-002, Survey Unit Classification as part of the survey design for FSS.
The Unit 1 Containment Building Penetrations, the Unit 2 Containment Building Penetrations and the Auxiliary Building Penetrations were initially classified as Class 1, Class 2, or Class 3, based on historical assessment, exposure to radioactive materials and system use. Based upon completion of the Survey Unit Classification Basis for final classification for each survey unit, which included a review of the historical information, the results of the Characterization Survey data and completion of a final Survey Unit Classification Worksheet, the correct final classification of penetrations within each building were validated. As a conservative measure, the classifications of all Unit 1 Containment Building Penetrations, Unit 2 Containment Building Penetrations and the Auxiliary Building Penetrations were changed to Class 1. Consequently, sufficient
~
=ZIONSOLUTIONSuc-AnEr,e,gy~Compaoy
FSS RELEASE RECORD, REV 1 PENETRATIONS SURVEY UNITS 01112, 02112 and 05120
[17]
measurements were taken in all penetrations to ensure 100% areal coverage of all accessible internal surfaces within the penetrations.
- 4.
DATA QUALITY OBJECTIVES (DQO)
FSS planning and design hinges on coherence with the DQO process to ensure, through compliance with explicitly defined inputs and boundaries, that the primary objective of the survey is satisfied. The DQO process, utilized in accordance with MARSSIM, is described in the ZSRP LTP, Section 5.6.2. The appropriate design for a given survey was developed using the DQO process as outlined in Appendix D of MARSSIM.
The DQO process incorporated hypothesis testing and probabilistic sampling distributions to control decision errors during data analysis. Hypothesis testing is a process based on the scientific method that compares a baseline condition to an alternate condition. The baseline condition is technically known as the null hypothesis. Hypothesis testing rests on the premise that the null hypothesis is true and that sufficient evidence must be provided for rejection. In designing the survey plan, the underlying assumption, or null hypothesis, was that residual activity in the survey unit exceeded the release criteria. Rejection of the null hypothesis would indicate that residual activity within the survey unit does not exceed the release criteria. Therefore, the survey unit would satisfy the primary objective of the FSS sample plan.
The primary objective of the FSS sample plan is to demonstrate that the level of residual radioactivity in the penetrations that comprised survey units 01112, 02112 and 05120 did not exceed the release criteria specified in the LTP and that the potential dose from residual radioactivity is As Low As Reasonably Achievable (ALARA).
ZionSolutions TSD 11-001, Technical Support Document for Potential Radionuclides of Concern During the Decommissioning of the Zion Station (Reference 9) established the basis for an initial suite of potential ROC for the decommissioning of the Zion Nuclear Power Station (ZNPS). LTP, Section 6.5.2 discusses the process used to derive the ROC for the decommissioning of ZNPS, including the elimination of insignificant dose contributors (IC) from the initial suite. Table 4, reproduced from LTP, Table 5-2 presents the ROC and the normalized mixture fractions based on the radionuclide mixture presented for the Auxiliary Building and Containment in TSD 14-019, Table 19.
~
=ZIONSOLUTIONSuc-AnEr,e,gy~Compaoy
FSS RELEASE RECORD, REV 1 PENETRATIONS SURVEY UNITS 01112, 02112 and 05120
[18]
Table 4 - Dose Significant Radionuclides and Mixture Radionuclide Containment Auxiliary Building(2)
% of Total Activity (normalized)(1)
% of Total Activity (normalized)(1)
H-3 0.08%
NA Co-60 4.72%
0.92%
Ni-63 26.50%
23.71%
Sr-90 0.03%
0.05%
Cs-134 0.01%
0.01%
Cs-137 68.17%
75.32%
Eu-152 0.44%
NA Eu-154 0.06%
NA (1) Based on maximum percent of total activity from Table 20 of TSD 14-019, normalized to one for the dose significant radionuclides.
(2) Does not include dose significant radionuclides for activated concrete (H-3, Eu-152, Eu-154).
A fundamental precursor to survey design is to establish a relationship between the release criteria and some measurable quantity. This is done through the development of DCGLs.
The DCGLs represent average levels of radioactivity above background levels and are presented in terms of surface or mass activity concentrations. Chapter 6 of the LTP describes in detail the modeling used to develop the DCGLs for penetrations.
The End State Basements are comprised of steel and/or concrete structures which will be covered by at least three feet of clean soil and physically altered to a condition which would not realistically allow the remaining structures, if excavated, to be occupied. The exposure pathways in the Basement Fill Model (BFM) are associated with residual radioactivity in floors and walls that is released through leaching into water contained in the interstitial spaces of the fill material. The BFM assumes that the inventory of residual radioactivity in a given building is released either instantly or over time by diffusion, depending on whether the activity is surficial or volumetric, respectively. The activity released into the fill water will adsorb into the clean fill, as a function of the radionuclide-specific distribution coefficients, resulting in equilibrium concentrations between the fill and the water.
Consequently, the only potential exposure pathways after backfilling, assuming the as-left geometry, are associated with the residual radioactivity in the water contained in the fill.
The final outputs of the BFM are the Penetration DCGLs, in units of pCi/m2, which are calculated using the BFM Groundwater and BFM Drilling Spoils Dose Factors (LTP, Tables 6-24 and 6-25), LTP Equation 6-10 and the ratios in LTP Table 6-51. The
~
=ZIONSOLUTIONSuc-AnEr,e,gy~Compaoy
FSS RELEASE RECORD, REV 1 PENETRATIONS SURVEY UNITS 01112, 02112 and 05120
[19]
BcDCGLPN are radionuclide-specific concentrations that represent the 10 CFR 20.1402 dose criterion of 25 mrem/yr and are calculated for each ROC and each backfilled basement. The unity rule is applied when there is more than one ROC. The measurement results for each singular ROC present in the mixture are compared against their respective DCGL to derive a dose fraction.
The BcDCGLPN for the unrestricted release of U1 and U2 Containments, Auxiliary Building and Turbine Building penetrations are provided in Table 5 (reproduced from LTP Chapter 5, Table 5-13). The IC dose percentages of 10% for both Containments and 5%
for all other survey units were used to adjust the DCGLPN values in Table 5 to account for the dose from the eliminated IC radionuclides.
Table 5 - Base Case DCGLs for Penetrations Radionuclide Auxiliary Bldg.
Unit 1/Unit 2 Containment Turbine Bldg.
(pCi/m2)
(pCi/m2)
(pCi/m2)
H-3 3.99E+09 3.42E+09 3.23E+09 Co-60 8.82E+07 2.26E+09 1.76E+09 Ni-63 6.79E+10 5.78E+10 5.48E+10 Sr-90 2.41E+07 2.06E+07 1.94E+07 Cs-134 3.28E+08 4.32E+08 4.00E+08 Cs-137 6.17E+08 5.66E+08 5.29E+08 Eu-152 3.29E+08 5.26E+09 4.06E+09 Eu-154 2.33E+08 4.58E+09 3.58E+09 Each radionuclide-specific BcDCGLPN is equivalent to the level of residual radioactivity (above background levels) that could, when considered independently, result in a Total Effective Dose Equivalent (TEDE) of 25 mrem/yr to an Average Member of the Critical Group (AMCG). To ensure that the summation of dose from each source term is 25 mrem/yr or less after all FSS is completed, the BcDCGLPN are reduced based on an expected, or a priori, fraction of the 25 mrem/yr dose limit from each source term. The reduced DCGLPN, or OpDCGLPN, can be related to the BcDCGLPN as an expected fraction of dose based on an a priori assessment of what the expected dose should be based on the results of site characterization, process knowledge and the extent of planned remediation.
The OpDCGLPN is then used as the DCGL for the FSS design of the survey unit (calculation of surrogate DCGLs, investigations levels, etc.). Details of the OpDCGLPN derived for each dose component and the basis for the applied a priori dose fractions are provided in ZionSolutions TSD 17-004, Operational Derived Concentration Guideline Levels for Final Status Survey (Reference 10). The Operational DCGLs for the FSS of penetrations are presented in Table 6 (reproduced from LTP 5, Table 5-14).
~
=ZIONSOLUTIONSuc-AnEr,e,gy~Compaoy
FSS RELEASE RECORD, REV 1 PENETRATIONS SURVEY UNITS 01112, 02112 and 05120
[20]
Table 6 - Operational DCGLs for Penetrations Radionuclide Auxiliary Bldg.
Unit 1/Unit 2 Containment Turbine Bldg.
(pCi/m2)
(pCi/m2)
(pCi/m2)
H-3 3.14E+08 2.33E+08 2.58E+08 Co-60 6.95E+06 1.54E+08 1.41E+08 Ni-63 5.35E+09 3.93E+09 4.38E+09 Sr-90 1.90E+06 1.40E+06 1.55E+06 Cs-134 2.58E+07 2.94E+07 3.20E+07 Cs-137 4.86E+07 3.85E+07 4.23E+07 Eu-152 2.59E+07 3.58E+08 3.25E+08 Eu-154 1.84E+07 3.11E+08 2.86E+08 LTP, Section 6.14 states that a penetration survey unit is defined for each basement. The direction that the residual radioactivity will migrate into a given basement, cannot be predicted with certainty; therefore, each penetration that begins in one basement and ends in another will be included in the survey units for both basements. The residual radioactivity in the penetration is assumed to release to both basements simultaneously.
LTP, Section 5.2.10 states that because a given penetration interfaces two basements, the lesser OpDCGLPN of the two basements will be used for FSS design and implementation.
To ensure that the residual radioactivity reported for penetrations was limiting regardless of interface or location, a set of most-limiting Base Case DCGLs and Operational DCGLs were derived by selecting the lower of the DCGLs for each ROC from the impacted buildings (Unit 1 Containment, Unit 2 Containment, the Auxiliary Building and the Turbine Building). The set of DCGLPN for the SFP/Transfer Canal was not included as all penetrations interfacing with the SFP/Transfer Canal were physically removed and disposed of as waste prior to the commencement of FSS. The most-limiting BcDCGLPN are presented in Table 7.
~
=ZIONSOLUTIONSuc-AnEr,e,gy~Compaoy
FSS RELEASE RECORD, REV 1 PENETRATIONS SURVEY UNITS 01112, 02112 and 05120
[21]
Table 7 - Most-Limiting Base Case DCGLs for Penetrations Radionuclide Most-Limiting (pCi/m2)
H-3 3.23E+09 Co-60 8.82E+07 Ni-63 5.48E+10 Sr-90 1.94E+07 Cs-134 3.28E+08 Cs-137 5.29E+08 Eu-152 3.29E+08 Eu-154 2.33E+08 The most-limiting OpDCGLPN are presented in Table 8.
Table 8 - Most-Limiting Operational DCGLs for Penetrations Radionuclide Most-Limiting (pCi/m2)
H-3 2.33E+08 Co-60 6.95E+06 Ni-63 3.93E+09 Sr-90 1.40E+06 Cs-134 2.58E+07 Cs-137 3.85E+07 Eu-152 2.59E+07 Eu-154 1.84E+07 Instrument DQOs included a verification of the ability of the survey instrument to detect the radiation(s) of interest relative to the OpDCGLPN. Survey instrument response checks were required prior to issuance and after the instrument had been used. Control and accountability of survey instruments was required to assure the quality and prevent the loss of data. The minimum acceptable minimum detectable concentration (MDC) for measurements obtained using field instruments was 50% of the applicable OpDCGLPN.
- 5.
SURVEY DESIGN The level of effort associated with planning a survey is based on the complexity of the survey and nature of the hazards. Guidance for preparing FSS plans is provided in procedure ZS-LT-300-001-001. The FSS plans for the survey of penetrations employed sample designs that combined hand-held scanning with static measurements and pipe detector survey methodologies.
The survey method for large diameter penetrations (>12) differs from smaller penetrations due to measurement sensitivity (i.e., MDCs) differences in the two size regimes. The larger
~
=ZIONSOLUTIONSuc-AnEr,e,gy~Compaoy
FSS RELEASE RECORD, REV 1 PENETRATIONS SURVEY UNITS 01112, 02112 and 05120
[22]
penetrations were surveyed using a similar approach to traditional building surface surveys, whereas the smaller penetrations were surveyed with a centrally positioned single detector advanced through the length of penetration in 1-foot increments.
Unit 1 Containment In Unit 1 Containment, sample plans S1-01112A-F #1 and S1-01112A-F #2 addressed the survey of penetrations smaller than 12 inches in diameter (P001, P003-P004, P019, P023, P042-P043, P050, P054, P056, P064, P081, P086-P089 and P103), and sample plan S1-01112A-F #3 addressed the survey of penetrations with a diameter greater than 12 inches (P005-P012, P017-P018, P020-P022, P066-P070, P073-P074, P090-P098, P-104-P105, P112-P113, P115-P118 and P127-P128). As an exception, the five 24-inch diameter penetrations for the Cavity Flood Sump and the Recirculating Sump suctions (P035-P037, P123 and P124 for Unit 1 Containment and P235-P237, P323 and P324 for Unit 2 Containment) were surveyed using the gamma detector approach as the length of the pipes
(~50 feet) prevented access solely by hand-held detectors. Instrument efficiencies were recalculated for a 23-inch diameter pipe, permitting one-foot interval static measurements along the approximate 50-foot length of each pipe. All 10 penetrations were subsequently grouted. See Figures 2 and 3.
Figure 2 - Recirculating Sump Suction Penetrations Grouted
~
=ZIONSOLUTIONSuc-AnEr,e,gy~Compaoy
FSS RELEASE RECORD, REV 1 PENETRATIONS SURVEY UNITS 01112, 02112 and 05120
[23]
Figure 3 - Cavity Flood Sump Suction Penetrations Grouted Unit 2 Containment In Unit 2 Containment, sample plans S1-02112A-F #1 and S1-02112A-F #2 addressed the survey of penetrations smaller than 12 inches in diameter (P201, P203-P204, P219, P223, P242-P243, P250, P254, P256, P264, P281, P286-P289 and P303), and sample plan S1-01112A-F #3 addressed the survey of penetrations with a diameter greater than 12 inches (P205-P212, P217-P218, P220-P222, P266-P270, P273-P274, P290-P298, P-304-P305, P312-P313, P315-P318 and P327-P328). As an exception, the five (5) 23-inch diameter penetrations for the Cavity Flood Sump and the Recirculating Sump suctions (P235-P237, P323 and P324) were surveyed using the gamma detector approach as the length of the pipes (~50 feet) prevented access solely by hand-held detectors.
The two (2) FSS sample plans for survey unit 05120, Auxiliary Building Penetrations includes FSS design and FSS results for the Auxiliary Building penetrations on the 542-foot, 560-foot and the 572-foot elevations. Sample plan S1-05120A-F #1 addressed the survey of penetrations smaller than 12 inches in diameter (A002, A003, A005, A007-A013, A015, A017 and A019-A023), and sample plan S1-05120A-F #2 addressed that survey of penetrations with a diameter greater than or equal to 12 inches in diameter (A001, A004, A014, A024 and A025).
~
=ZIONSOLUTIONSuc-AnEr,e,gy~Compaoy
FSS RELEASE RECORD, REV 1 PENETRATIONS SURVEY UNITS 01112, 02112 and 05120
[24]
Auxiliary Building Penetrations and buried pipe associated with the west wall of the Auxiliary Building (Unit 1 and Unit 2 Hot Pipe Chases at the 570-foot elevation and buried pipe associated with the SFP) were physically removed and disposed of as radioactive waste. The penetrations that were removed in their entirety were A006, A016, A018, A029, A034, A037, A038, A039, A040, A041, A042, A043, A044, A046, A047, A048, A049, A050, A052, A053, A054, A055, A056, A057, A058, A059, A060, A061, A063, A064, A065, and A066.
There are twenty-two (22) penetrations that remain in Auxiliary Building that were not attributed to the Containments. The remaining penetrations are located primarily on the G Wall between the Auxiliary Building and the Turbine Building.
Section 5.1 of LTP Chapter 5 states that H-3, Co-60, Ni-63, Sr-90, Cs-134, Cs-137, Eu-152, and Eu-154 are the ROC in the Containments, and Co-60, Ni-63, Sr-90, Cs-134, and Cs-137 are the ROC in the Auxiliary Building and Turbine Building. During FSS, concentrations for Hard-to-Detect (HTD) ROC H-3, Ni-63, and Sr-90 are inferred using a surrogate approach. Cs-137 is the principle surrogate radionuclide for H-3 and Sr-90, and Co-60 is the principle surrogate radionuclide for Ni-63. The mean, maximum and 95%
Upper Confidence Level (UCL) of the surrogate ratios for concrete core samples taken in the Containments and Auxiliary Building basements were calculated in ZionSolutions TSD 14-019, Radionuclides of Concern for Soil and Basement Fill Model Source Terms (Reference 11) and are presented in Table 9 (reproduced from LTP, Table 5-12). The maximum ratios were used in the surrogate calculations during FSS.
Table 9 - Containment and Auxiliary Building Surrogate Ratios Ratios Containment Auxiliary Building Max Max H-3/Cs-137 1.760 N/A Ni-63/Co-60 442 180.450 Sr-90/Cs-137 0.021 0.002 For the FSS of all Containment penetrations, the surrogate OpDCGLPN for H-3, Co-60 and Cs-137 were computed based on the maximum ratios for Containment from Table 9. For the FSS of the Auxiliary Building and the Turbine Building, the surrogate OpDCGLPN for Co-60 and Cs-137 were computed based on the maximum ratios for the Auxiliary Building from Table 9. The applicable maximum ratios were used to infer concentrations for HTD ROC depending on location.
~
=ZIONSOLUTIONSuc-AnEr,e,gy~Compaoy
FSS RELEASE RECORD, REV 1 PENETRATIONS SURVEY UNITS 01112, 02112 and 05120
[25]
The equation for calculating a surrogate DCGL is as follows:
Equation 1
=
1
[(
1
) + (
2
- 2) + (
3
- 3) + (
)]
Where:
DCGLSur
= Surrogate radionuclide DCGL DCGL2,3n = DCGL for radionuclides to be represented by the surrogate Rn
= Ratio of concentration (or nuclide mixture fraction) of radionuclide n to surrogate radionuclide Using the OpDCGLPN presented in Table 8 and the maximum ratios from Table 9, a surrogate OpDCGL for Co-60 of 3.90E+06 pCi/m2 and a surrogate OpDCGL for Cs-137 of 2.06E+07 pCi/m2 was derived.
Using the normalized mixture for gamma-emitting ROC in the Containment from Table 4 and the surrogate adjusted OpDCGLs for gamma-emitting ROC, a gross gamma measurement of 3.59E+05 dpm/100 cm2 was determined as an Action Level. This value was used as the action level for hand-held scan and static measurements and pipe detector static measurements in this survey unit. Action levels in counts per minute (cpm) for pipe detector surveys were calculated using the action level, the effective area of detection for the various diameter penetrations, and the associated efficiency for each size penetration and the instrument/detector combination. Table 10 provides a summary of the instrumentation and action levels used for the FSS of the penetrations.
Table 10 - Penetrations FSS Instrumentation and Action Levels Survey Type Instrument Detector Penetration Diameter (in)
Efficiency Action Level (cpm)
Hand-held Ludlum 2350-1 Ludlum 43-68 14-50 0.297 to 0.298(1) 51,806 to 53,620 Ludlum 2360 Ludlum 43-93 14-50 0.114 to 0.129(1) 14,600 to 24,160 Pipe Detector Ludlum 2350-1 Ludlum 44-157 6
0.012(2) 32,695 8
0.009(2) 32,751 Ludlum 44-162 10 0.018(2) 81,625 12 0.016(2) 87,186 23 0.0142(2) 148,131 (1) Efficiency determined using Tc-99 source. Derived instrument efficiency of x source efficiency of 0.81 (NUREG-1507, Table 5.4)
(2) Efficiency empirically derived using conformable Cs-137 source in various ID pipe jigs
~
=ZIONSOLUTIONSuc-AnEr,e,gy~Compaoy
FSS RELEASE RECORD, REV 1 PENETRATIONS SURVEY UNITS 01112, 02112 and 05120
[26]
For a Class 1 penetration survey unit, the Investigation Levels for area scanning and static measurement results are those levels specified in LTP, Table 5-25, and are reproduced below in Table 11.
Table 11 - Investigation Levels Classification Scan Investigation Levels Direct Investigation Levels Class 1
>Operational DCGL or
>MDCscan if MDCscan is greater than Operational DCGL
>Operational DCGL Two (2) survey methodologies were utilized for the FSS of the penetrations, pipe detector survey or hand-held survey. This was due to the varying diameters and lengths of the penetrations. The survey designs for the FSS of penetrations using the different methodologies are detailed below.
The first methodology is the use of a pipe detector to acquire measurements inside of the penetrations. This methodology is applicable to sixty-one (61) of the 149 penetrations impacting the Containments, Auxiliary Building and Turbine Building. Penetrations subjected to this method for FSS were mostly twelve (12) inches in diameter or smaller.
The exceptions are the five (5) 23-inch diameter sump penetrations in each Containment which were designated to be surveyed with a pipe detector because of their length (approximately 50 feet each). The total length of the penetrations surveyed using the pipe detector methodology is 730.38 feet (222.62 m) with a total interior surface area of 331.42 m2. Refer to Table 10 for the FSS instrumentation summary.
As a Class 1 survey unit, the survey design required a 100% areal coverage. For the survey of pipe or penetration internal surfaces that cannot be practically surveyed using a hand-held detector methodology, areal coverage is achieved by the area of detection for each static measurement taken. Scanning, in the traditional context, is not applicable to this type of survey. With a 1-foot area of detection, a 1-minute static measurement at 1-foot increments throughout the penetration length was sufficient to provide 100% areal coverage. For the approximate 730 feet of penetrations to be surveyed during FSS using pipe detectors, at least 730 measurements were required to satisfy the 100% coverage requirement.
The second methodology that was used for the FSS of penetrations is the use of a hand-held detector to acquire measurements inside of the penetrations. This methodology is applicable to 88 of the 149 penetrations impacting the Containments, Auxiliary Building and Turbine Building. Penetrations subjected to this method for FSS were larger than twelve (12) inches in diameter.
~
=ZIONSOLUTIONSuc-AnEr,e,gy~Compaoy
FSS RELEASE RECORD, REV 1 PENETRATIONS SURVEY UNITS 01112, 02112 and 05120
[27]
The total length of the penetrations under the hand-held methodology is 351.90 feet (107.26 m) with a total interior surface area of 190.64 m2. For the survey of these larger diameter pipes, the survey design required 100% scan of the accessible interior surfaces of the penetration. In addition, a minimum of one 1-minute static measurement was acquired in each penetration at systematic locations based on a triangular grid, and at least one 1-minute static measurement was acquired in each penetration at the location of the highest scan result. Maps of the penetrations and measurement locations are provided in.
For the Unit 1 Containment, the sixteen (16) systematic static measurement locations are denoted in Table 12 below. The locations were developed using Visual Sample Plan (VSP) using a pre-determined number of measurements (16) with a random start point on a triangular grid superimposed on the laid out interior surface area of the relevant penetrations.
Table 12 - Systematic Static Locations for Hand-Held Surveys in Unit 1 Containment Penetrations Measurement No.
Penetration No.
Inches into Penetration Inches Clockwise from 12 oclock 1
P005 24 96 2
P007 16 45 3
P007 16 148 4
P009 9
96 5
P011 1
45 6
P012 42 96 7
P018 25 45 8
P022 28 45 9
P074 56 45 10 P090 24 9
11 P094 9
9 12 P097 43 9
13 P104 35 60 14 P112 8
9 15 P116 41 9
16 P128 27 9
~
=ZIONSOLUTIONSuc-AnEr,e,gy~Compaoy
FSS RELEASE RECORD, REV 1 PENETRATIONS SURVEY UNITS 01112, 02112 and 05120
[28]
For the Unit 2 Containment, the sixteen (16) systematic static measurement locations are denoted in Table 13 below. The locations were developed using VSP using a pre-determined number of measurements (16) with a random start point on a triangular grid superimposed on the laid out interior surface area of the relevant penetrations.
Table 13 - Systematic Static Locations for Hand-Held Surveys in Unit 2 Containment Penetrations Measurement No.
Penetration No.
Inches into Penetration Inches Clockwise from 12 oclock 1
P205 13 26 2
P205 13 136 3
P207 13 81 4
P209 12 26 5
P211 12 81 6
P217 11 26 7
P221 28 26 8
P266 5
26 9
P269 22 26 10 P274 39 26 11 P290 14 80 12 P292 13 25 13 P296 12 25 14 P305 1
25 15 P315 38 25 16 P327 37 25 For the Auxiliary Building, seventeen (17) static measurements (15 systematic and 2 QC) were acquired in the large diameter penetrations with the locations selected as denoted in Table 14 below. The locations were developed using VSP using a pre-determined number of measurements (16) with a random start point on a triangular grid superimposed on the laid out interior surface area of the relevant penetrations.
~
=ZIONSOLUTIONSuc-AnEr,e,gy~Compaoy
FSS RELEASE RECORD, REV 1 PENETRATIONS SURVEY UNITS 01112, 02112 and 05120
[29]
Table 14 - Systematic Static Locations for Hand-Held Surveys in Auxiliary Building Penetrations Measurement No.
Penetration No.
Inches into Penetration (1) 1 A001 12 2
A001 24 3
A001 36 4
A014 12 5
A014 24 6
A014 36 7
A014 36 8
A004 12 9
A004 24 10 A004 36 11 A024 12 12 A024 24 13 A024 36 14 A025 12 15 A025 24 16 A025 36 17 A025 36 (1) Static measurements were acquired on the bottom of the penetration circumference.
The implementation of quality control measures as referenced by LTP, Section 5.9 and ZionSolutions ZS-LT-01, Quality Assurance Project Plan (for Characterization and FSS) (QAPP) (Reference 12) includes the collection of a replicate measurement on 5% of the measurements taken with the locations selected at random. One (1) measurement out of every twenty (20) was required for QC compliance.
- 6.
SURVEY IMPLEMENTATION Survey instructions for this FSS were incorporated into and performed in accordance with FSS sample plans S1-01112A-F #1, #2, and #3 for Unit 1 Containment; sample plans S1-02112A-F #1, #2, and #3 for Unit 2 Containment; and sample plans S1-05120A-F #1 and
- 2 for the Auxiliary Building. FSS sample plans were developed in accordance with ZionSolutions procedure ZS-LT-300-001-001. The FSS unit was inspected and controlled in accordance with ZionSolutions procedure ZS-LT-300-001-003, Isolation and Control for Final Status Survey (Reference 13).
~
=ZIONSOLUTIONSuc-AnEr,e,gy~Compaoy
FSS RELEASE RECORD, REV 1 PENETRATIONS SURVEY UNITS 01112, 02112 and 05120
[30]
Surveys of both the Unit 1 and Unit 2 Containment Building penetrations began on March 9, 2018, and concluded on April 19, 2018. The survey design estimated six (6) working days to implement the FSS in parallel with any required decontamination and inspection activities. In reality, ten (10) working days were necessary to complete this work.
Surveys of the Auxiliary Building Penetrations began on March 27, 2018, and concluded on March 28, 2018. The survey design estimated seven (7) working days to implement the FSS in parallel with any required decontamination and inspection activities. In reality, only two (2) working days were necessary to complete this work. Throughout these activities, briefings were conducted on a daily basis to discuss the expectations for job performance and to review the safety aspects of the job.
Visual inspections of the penetrations were performed prior to the start of the survey.
Inspections were performed to ensure that the penetrations were relatively dry and free of debris.
For pipe detector surveys using a NaI detector, a background value was determined for the detector/instrument combination to be used prior to deployment. The background value was obtained at the location where the pre-use response check of the instrument was performed. The background value was primarily used to ensure that the detector had not become cross-contaminated by any previous use. Background was not subtracted from any measurement.
Daily, prior to and following use, each detector was subjected to an Operational Response Check in accordance with procedure ZS-LT-300-001-006, Radiation Surveys of Pipe Interiors Using Sodium/Cesium Iodide Detectors (Reference 14). The daily Operational Response Check compared the background response to check source ranges established for normal background and detector source response. This check ensured that the detector was working properly.
Once the detector was determined to be fully functional, it was then deployed to the field for insertion into the targeted penetrations. A one-minute static measurement was acquired at each foot traversed into the penetrations. The detector output represented the gamma activity for each one-minute timed measurement in units of gross cpm. The gamma measurement value in units of cpm was then converted to units of dpm using the efficiency factor for the detector applicable to the diameter of the penetration surveyed.
Each measurement assumed a conservative area of detection for the NaI detector of one foot. This assumption is conservative because there is additional instrument response from contamination located in the pipe at distances outside of the area of detection.
Consequently, the total activity from the measurement, in units of dpm, is adjusted for the total effective surface area commensurate with the penetration diameter and the assumed area of detection, resulting in measurement results in units of dpm/100 cm2. Using the
~
=ZIONSOLUTIONSuc-AnEr,e,gy~Compaoy
FSS RELEASE RECORD, REV 1 PENETRATIONS SURVEY UNITS 01112, 02112 and 05120
[31]
appropriate conversion factors, the result is then converted to units of pCi/m2. This measurement result represents a commensurate and conservative gamma surface activity for the one foot of pipe surface where the measurement was taken.
For the penetration surveys performed with hand-held detectors, a background value was determined for the detector/instrument combination as the average of five (5) ambient 1-minute static measurements. An Alarm Set Point was developed using the background value plus the gross-gamma Action Level of 3.59E+05 dpm/100 cm2.
The entire surface area (100%) of the interior surface area of the designated penetrations were scanned using either the Ludlum 2350-1 paired with a pipe detector or a Ludlum 2360 paired with a Ludlum 43-93 detector operated in the rate-meter mode and using audio response. The probe was positioned as close to the surface as possible and was moved at a scan speed of 2.0 inches per second.
Systematic 1-minute static measurements were acquired at the locations denoted in Table 6. Additionally, 1-minute static measurements were taken at the locations of highest scan result in each penetration. Using the established efficiencies, the static measurement activities in cpm were converted to activities in dpm/100 cm2 and then to pCi/m2 using the appropriate conversion factor.
- 7.
SURVEY RESULTS After completion of the FSS measurements in the penetrations, the sample plans were reviewed to confirm the completeness of the survey and the survey data was validated in accordance with procedure ZS-LT-300-001-004, Final Status Survey Data Assessment (Reference 15). Data processing included converting measurement data into reporting units, validating instrument applicability and sensitivity, calculating relevant statistical quantities, and verification that all DQO have been met.
For measurements acquired with a NaI detector, the gross output of the measurement is converted to units of dpm by dividing by the efficiency. The effective FOV of the measurement is calculated based upon diameter of the pipe at a length of 1 foot. The result, following unit conversion, is a gross gamma measurement result in units of pCi/m2.
For measurements acquired as a direct static measurement with a hand-held detector, the gross gamma output of the measurement is again converted to units of dpm by dividing by the efficiency. As the detector has an area of 100 cm2, the units for the measurement are actually in units of dpm/100cm2. Again, through unit conversion, units of dpm/100cm2 are converted to units of pCi/m2.
Using the mixture from Table 5-2 of LTP Chapter 5 (reproduced as Table 8 of this Release Record), the gross gamma result from each measurement is multiplied by the normalized
~
=ZIONSOLUTIONSuc-AnEr,e,gy~Compaoy
FSS RELEASE RECORD, REV 1 PENETRATIONS SURVEY UNITS 01112, 02112 and 05120
[32]
gamma mixture fractions for Co-60, Cs-134, Cs-137, Eu-152 and Eu-154 to derive a radionuclide specific concentration for each gamma ROC. The HTD ROC concentrations for H-3, Ni-63 and Sr-90 were then inferred using the maximum surrogate ratios from LTP, Table 5-15 (reproduced as Table 13 of this Release Record). Each concentration for each measurement is then compared against the most-limiting OpDCGLPN to produce an OpSOF for each ROC, which were when summed to derive an OpSOF for the measurement.
In accordance with LTP, Section 5.5.5, penetration survey units also have total surface areas that are less than the area of the wall/floor surface survey unit that the penetrations interface. To eliminate the potential for activity levels in penetrations that could lead to releases greater than the adjacent basement walls and floors, the results are also compared against the OpDCGL for surfaces from LTP, Table 5-4 of the two building that the penetration interfaces.
To ensure that the grouting requirements of LTP, Section 5.5.5 were met, a set of most-limiting Operational DCGLs for Building Structures (OpDCGLB) were derived by selecting the lower of the DCGLs for each ROC from the impacted buildings (Unit 1 Containment, Unit 2 Containment, the Auxiliary Building and the Turbine Building) from LTP, Table 5-4. The set of DCGLB for the SFP/Transfer Canal was not included as all penetrations interfacing with the SFP/Transfer Canal were physically removed and disposed of as waste prior to the commencement of FSS. The most-limiting OpDCGLB are presented in Table 15. The residual radioactivity reported for penetrations was then compared against the set of most-limiting OpDCGLB to determine the necessity to grout, regardless of interface or location.
Table 15 - Most Limiting OpDCGLs for Structures from LTP Chapter 5, Table 5-4 Radionuclide Most-Limiting (pCi/m2)
H-3 1.10E+07 Co-60 5.98E+06 Ni-63 1.85E+08 Sr-90 6.58E+04 Cs-134 1.35E+06 Cs-137 1.79E+06 Eu-152 1.38E+07 Eu-154 1.22E+07
~
=ZIONSOLUTIONSuc-AnEr,e,gy~Compaoy
FSS RELEASE RECORD, REV 1 PENETRATIONS SURVEY UNITS 01112, 02112 and 05120
[33]
The penetrations were segregated into four groups: penetrations that interfaced with Unit 1 Containment, penetrations that interfaced with Unit 2 Containment, penetrations that interfaced with the Auxiliary Building and penetrations that interfaced with the Turbine Building. In all cases, a penetration was captured in two of the four groups. This is due to the requirement that the dose from a penetration is assumed to provide the same dose to each of the structures that it interfaces with. For example, if a penetration interfaced with the Unit 1 Containment and the Turbine Building, that penetration will be denoted as a member of both the Unit 1 Containment population and the Turbine Building population simultaneously.
Table 16 provides the summary of the Unit 1 Containment penetrations, a summary of the FSS results, and whether the penetration required grouting. Included are the penetrations that interface with the Auxiliary Building and the Turbine Building. Those penetrations are included in Table 16 and they are not included in the summary for the Auxiliary Building in Table 20. All penetrations that interface with the Unit 1 Containment (Auxiliary Building and the Turbine Building) are included in 369 measurements taken for the Unit 1 Containment. The complete tables containing the measurement results of all Unit 1 Containment measurements that were taken are presented in Attachment 2. The measurement data passed the Sign Test. The results of the Sign Test are provided in. The statistical summary of the measurement data taken, when compared against the most-limiting BcDCGLPN from Table 7 of this Release Record are presented in Table 17.
~
=ZIONSOLUTIONSuc-AnEr,e,gy~Compaoy
FSS RELEASE RECORD, REV 1 PENETRATIONS SURVEY UNITS 01112, 02112 and 05120
[34]
Table 16 - Unit 1 Containment Penetrations Summary Pen.
No.
Description Diameter Surface Area Length Interface With
- of Measurements By Direct Scan Most Limiting DCGLs (1)
Require Grouting End-State Condition (in)
(m2)
(m)
OpSOFPN OpSOFB P001 Fire Protection 10 1.22 1.52 AUX 5
0.402 7.339 YES Removed P003 Spare 6
0.73 1.52 AUX 3
0.282 5.146 YES Removed P004 Boron Injection Tank to Cold Legs 8
0.97 1.52 AUX 5
0.325 5.931 YES Removed P005 Main Steam 50 4.86 1.22 TB 1
X 0.003 0.056 Open/Buried P006 Main Steam 50 4.86 1.22 TB 1
X 0.004 0.081 Open/Buried P007 Main Steam 50 4.86 1.22 TB 2
X 0.003 0.055 Open/Buried P008 Main Steam 50 4.86 1.22 TB 1
X 0.005 0.082 Open/Buried P009 Feedwater 32 3.11 1.22 TB 1
X 0.003 0.060 Open/Buried P010 Feedwater 32 3.11 1.22 TB 1
X 0.004 0.073 Open/Buried P011 Feedwater 32 3.11 1.22 TB 1
X 0.002 0.028 Open/Buried P012 Feedwater 32 3.11 1.22 AUX 2
X 0.008 0.145 Removed P017 Reactor Coolant 2 Loop to RHR Pumps 28 3.41 1.52 AUX 1
X 0.008 0.145 Removed P018 Cavity Fill Pump 1A Discharge 18 2.19 1.52 AUX 1
X 0.005 0.088 YES Removed P019 Reactor Coolant 1 to RHR Pumps 12 1.46 1.52 AUX 5
0.401 7.319 YES Removed P020 Cavity Fill Pump 1B Discharge 18 2.19 1.52 AUX 1
X 0.265 4.831 YES Removed P021 Spare 28 3.41 1.52 AUX 1
X 1.034 18.870 YES Removed P022 RHR to RC Loop Cold Legs 28 3.41 1.52 AUX 1
X 1.729 31.568 Removed P023 RHR to RC Loop Cold Legs 12 1.46 1.52 AUX 5
0.039 0.714 YES Removed P035 Recirculating Sump Suction 23 28.53 15.55 AUX 51 0.376 6.862 YES Grouted P036 Cavity Flood Sump Suction 23 28.53 15.55 AUX 51 0.677 12.364 YES Grouted P037 Cavity Flood Sump Suction 23 28.53 15.55 AUX 51 0.897 16.381 YES Grouted P042 CTMT Sump Discharge to Drain Tank 6
0.73 1.52 AUX 5
0.591 10.793 YES Removed P043 RC Drain Pump to Hold-Up Tank 8
0.97 1.52 AUX 5
0.302 5.522 YES Removed P050 Spare 10 1.22 1.52 AUX 3
0.306 5.591 YES Removed P054 Containment Pressure 6
0.73 1.52 AUX 5
0.233 4.259 YES Removed P056 Filtered Vents 8
0.97 1.52 AUX 5
0.276 5.042 YES Removed P064 Spare 10 1.22 1.52 AUX 3
0.443 8.088 YES Removed P066 RC Pump Seal Water Supply Lines 14 1.7 1.52 AUX 1
X 0.300 5.481 Removed P067 Spare 18 2.19 1.52 AUX 1
X 0.004 0.081 YES Removed P068 Aux Feedwater to Steam Gen 1C 14 1.7 1.52 AUX 1
X 0.127 2.317 Removed P069 Aux Feedwater to Steam Gen 1A 14 1.7 1.52 AUX 1
X 0.004 0.075 Removed
~
=ZIONSOLUTIONSuc-
""E""IW~eomi,.,,y
FSS RELEASE RECORD, REV 1 PENETRATIONS SURVEY UNITS 01112, 02112 and 05120
[35]
Table 16 (continued) - Unit 1 Containment Penetrations Summary Pen.
No.
Description Diameter Surface Area Length Interface With
- of Measurements By Direct Scan Most Limiting DCGLs (1)
Require Grouting End-State Condition (in)
(m2)
(m)
OpSOFPN OpSOFB P070 Cavity Drain to Purification Pump 14 1.7 1.52 AUX 1
X 0.011 0.193 Removed P073 Spare 18 2.19 1.52 AUX 1
X 0.218 3.989 YES Removed P074 Aux Feedwater to Steam Gen 1D 14 1.7 1.52 AUX 1
X 0.004 0.065 Removed P081 Non-Filtered Vents 8
0.97 1.52 AUX 5
0.235 4.285 YES Removed P086 RC Hot Leg Samples 10 1.22 1.52 AUX 5
0.298 5.437 YES Removed P087 Spare 10 1.22 1.52 AUX 3
0.552 10.071 YES Removed P088 Heating System Hot Water Supply 12 1.46 1.52 AUX 5
0.233 4.251 YES Removed P089 Heating System Hot Water Return 12 1.46 1.52 AUX 5
0.306 5.590 YES Removed P090 Spare 28 3.41 1.52 AUX 1
X 0.349 6.376 YES Removed P091 Blowdown Steam Generator 1A 16 1.56 1.22 TB 1
X 0.003 0.051 Open/Buried P092 Blowdown Steam Generator 1A 16 1.56 1.22 TB 1
X 0.002 0.042 Open/Buried P093 Blowdown Steam Generator 1C 16 1.56 1.22 TB 1
X 0.006 0.118 Open/Buried P094 Blowdown Steam Generator 1C 16 1.56 1.22 TB 1
X 0.003 0.062 Open/Buried P095 Blowdown Steam Generator 1A 14 1.36 1.22 TB 1
X 0.002 0.042 Open/Buried P096 Blowdown Steam Generator 1C 14 1.36 1.22 TB 1
X 0.003 0.048 Open/Buried P097 Blowdown Steam Generator 1D 14 1.36 1.22 TB 1
X 0.002 0.041 Open/Buried P098 Blowdown Steam Generator 1B 14 1.36 1.22 TB 1
X 0.002 0.044 Open/Buried P103 Spare 8
0.97 1.52 AUX 5
0.354 6.459 YES Removed P104 SIM to Aux F.S. Pumps 24 2.92 1.52 AUX 1
X 0.004 0.075 Removed P105 RHR to RC Loop Hot Legs 18 2.19 1.52 AUX 1
X 0.067 1.217 YES Removed P112 Steam Generator Blowdown Sample 16 1.56 1.22 TB 1
X 0.003 0.060 Open/Buried P113 Steam Generator Blowdown Sample 16 1.56 1.22 TB 1
X 0.002 0.035 Open/Buried P115 Blowdown (Steam Generator 1D) 16 1.56 1.22 TB 1
X 0.005 0.085 Open/Buried P116 Blowdown (Steam Generator 1D) 16 1.56 1.22 TB 1
X 0.002 0.042 Open/Buried P117 Blowdown (Steam Generator 1B) 16 1.56 1.22 TB 1
X 0.003 0.049 Open/Buried P118 Blowdown (Steam Generator 1B) 16 1.56 1.22 TB 1
X 0.002 0.044 Open/Buried P123 Recirculating Sump Suction 23 29.09 15.85 AUX 50 10.082 184.052 YES Grouted P124 Recirculating Sump Suction 23 29.09 15.85 AUX 50 3.103 56.645 YES Grouted P127 Steam to Aux FW Pumps 16 1.56 1.22 TB 1
X 0.004 0.075 Open/Buried P128 Steam to Aux FW Pumps 16 1.56 1.22 TB 1
X 0.003 0.050 Open/Buried (1) Compared against the most limiting OpDCGLPN (Table 8) and OpDCGLB (Table 15)
~
=ZIONSOLUTIONSuc-
""E""IW~eomi,.,,y
FSS RELEASE RECORD, REV 1 PENETRATIONS SURVEY UNITS 01112, 02112 and 05120
[36]
Table 17 - Summary of Unit 1 Containment Penetrations FSS Statistics Individual Measurement Metrics Total Number of Systematic Measurements = 369 Number of Quality Control Measurements = 19 Number of Judgmental/Investigational Measurements = 0 Total Number of Measurements = 388 Mean Systematic Measurement OpSOFPN = 0.661 Max Individual Systematic Measurement OpSOFPN = 10.082 Number of Systematic Measurements with OpSOF >1 = 45 ROC MEAN MEDIAN MAX MIN ST DEV BcDCGLPN BcSOFPN DOSE (pCi/m2)
(pCi/m2)
(pCi/m2)
(pCi/m2)
(pCi/m2)
(pCi/m2)
(mrem/yr)
H-3 1.75E+07 3.90E+06 2.67E+08 3.68E+04 4.32E+07 3.23E+09 0.005 0.135 Co-60 6.87E+05 1.53E+05 1.05E+07 1.45E+03 1.70E+06 8.82E+07 0.008 0.195 Ni-63 3.04E+08 6.78E+07 4.63E+09 6.40E+05 7.51E+08 5.48E+10 0.006 0.139 Sr-90 2.08E+05 4.65E+04 3.18E+06 4.39E+02 5.16E+05 1.94E+07 0.011 0.269 Cs-134 1.46E+03 3.25E+02 2.22E+04 3.07E+00 3.60E+03 3.28E+08 0.000 0.000 Cs-137 9.92E+06 2.22E+06 1.51E+08 2.09E+04 2.46E+07 5.29E+08 0.019 0.469 Eu-152 6.40E+04 1.43E+04 9.77E+05 1.35E+02 1.58E+05 3.29E+08 0.000 0.005 Eu-154 8.73E+03 1.95E+03 1.33E+05 1.84E+01 2.16E+04 2.33E+08 0.000 0.001 The mean BcSOF for Unit 1 Containment penetrations (survey unit 01112), when compared against the most-limiting BcDCGLPN is 0.048, which equates to a dose of 1.212 mrem/yr.
Forty-five (45) measurements exceeded the most-limiting OpDCGLPN but were less than the BcDCGLPN. The OpSOF (based on the OpDCGLPN) for a systematic or a judgmental measurement(s) may exceed one without remediation as long as the survey unit passes the Sign Test and, the mean OpSOF (based on the OpDCGLPN) for the survey unit does not exceed one. Once the survey data set passed the Sign Test (using OpDCGLPN), the mean radionuclide activity (pCi/m2) for each ROC from systematic measurements along with any identified elevated areas from systematic and judgmental measurements were used with the BcDCGLPN to perform a mean BcSOF calculation. The mean BcSOF for the Unit 1 Containment Penetrations was adjusted to include the dose from elevated measurements using Equation 5-6 from LTP, Section 5.5.5, reproduced as Equation 2. The mean BcSOF for the survey unit was then adjusted by adding the SOF from the elevated areas to the mean to account for the additional dose attributed to the elevated areas.
None of the 45 identified elevated penetrations interfaced with the Turbine Building. In accordance with LTP, Table 6-50, the adjusted surface area of the Unit 1 Containment Penetrations FSS unit (SASU) was 242.36 m2. The surface area of each of the elevated
~
=ZIONSOLlJTJONSLLc-
,..,ErawSCIMionlCompany
FSS RELEASE RECORD, REV 1 PENETRATIONS SURVEY UNITS 01112, 02112 and 05120
[37]
measurements was 1.096 m2, which equates to the FOV of each individual static measurement in the large 23-inch pipe. The individual elevated SOF for each elevated ROC were then summed to provide a total SOF adjustment due to each of the 45 elevated measurements.
Equation 2
/=
/
/
=1
+
( / /)
[/x (
)]
where:
BcSOFEP/PN
= BcSOF for embedded pipe or penetration survey unit within a basement using BcDCGLs Mean ConcEP/PN ROCi
= Mean concentration for the systematic measurements taken during the FSS of embedded pipe or penetrations in survey unit for each ROCi BcDCGLEP/PN ROCi
= BcDCGLEP/PN for embedded pipe or penetration for each ROCi Elev ConcEP/PN ROCi
= Concentration for ROCi in any identified elevated area (systematic or judgmental)
SAElev
= surface area of the elevated area SASU
= surface area of FSS unit The calculation to derive the adjustment to the mean BcSOF is presented in Attachment 2.
The mean BcSOF for Containment penetrations was adjusted by a value of 0.053 to account for the identified elevated measurements. The adjusted mean BcSOF for Unit 1 Containment was 0.101, which equated to the dose assigned to the survey unit of 2.537 mrem/yr. This value is the dose assigned to the survey unit based on the average of the systematic measurements adjusted for the dose contribution of the identified elevated measurements. In accordance with LTP, Section 6.4.5, the SOF of 0.101 or a dose value of 2.537 mrem/yr will be added to the Unit 1 Containment basement.
The OpSOF for 332 measurements in 29 penetrations that interfaced with Unit 1 Containment exceeded an OpSOF of one when compared against the most-limiting OpDCGLB for basement surfaces (Table 15). Consequently, in accordance with LTP, Section 5.5.5, the 29 penetrations cited would have required grouting. However, 24 of the 29 penetrations that exceeded the criteria were physically removed and disposed of as waste during building demolition. Only the remaining five (5) Unit 1 Containment Building Penetrations were actually grouted. No dose reduction was attributed to the survey unit because of grouting.
~
=ZIONSOLlJTJONSLLc-
,..,ErawSCIMionlCompany
FSS RELEASE RECORD, REV 1 PENETRATIONS SURVEY UNITS 01112, 02112 and 05120
[38]
Table 18 provides the summary of the Unit 2 Containment penetrations, a summary of the FSS results, and whether the penetration required grouting. Included are the penetrations that interface with the Auxiliary Building and the Turbine Building. Those penetrations are included in Table 18 and they are not included in the summary for the Auxiliary Building in Table 20. All penetrations that interface with the Unit 2 Containment (Auxiliary Building and the Turbine Building) are included in 369 measurements taken for the Unit 2 Containment. The complete tables containing the measurement results of all Unit 2 Containment measurements that were taken are presented in Attachment 2. The measurement data passed the Sign Test. The results of the Sign Test are provided in. The statistical summary of the measurement data taken, when compared against the most-limiting BcDCGLPN (Table 7) are presented in Table 19.
The OpSOF for 332 measurements in 29 penetrations that interfaced with Unit 1 Containment exceeded an OpSOF of one when compared against the most-limiting OpDCGLB for basement surfaces (Table 15). Consequently, in accordance with LTP, Section 5.5.5, the 29 penetrations cited would have required grouting. However, 24 of the 29 penetrations that exceeded the criteria were physically removed and disposed of as waste during building demolition. Only the remaining five (5) Unit 1 Containment Building Penetrations were actually grouted. No dose reduction was attributed to the survey unit because of grouting.
~
=ZIONSOLlJTJONSLLc-
,..,ErawSCIMionlCompany
FSS RELEASE RECORD, REV 1 PENETRATIONS SURVEY UNITS 01112, 02112 and 05120
[39]
Table 18 - Unit 2 Containment Penetrations Summary Pen.
No.
Description Diameter Surface Area Length Interface With
- of Measurements By Direct Scan Most Limiting DCGLs (1)
Require Grouting End-State Condition (in)
(m2)
(m)
OpSOFPN OpSOFB P201 Fire Protection 10 1.22 1.47 AUX 4
0.803 14.658 YES Removed P203 Spare 6
0.73 1.47 AUX 5
0.120 2.185 YES Removed P204 Boron Injection Tank to Cold Legs 8
0.97 1.47 AUX 5
0.460 8.400 YES Removed P205 Main Steam 50 4.86 1.22 TB 1
X 0.015 0.271 Open/Buried P206 Main Steam 50 4.86 1.22 TB 1
X 0.002 0.034 Open/Buried P207 Main Steam 50 4.86 1.22 TB 1
X 0.002 0.032 Open/Buried P208 Main Steam 50 4.86 1.22 TB 1
X 0.005 0.092 Open/Buried P209 Feedwater 32 3.11 1.22 TB 1
X 0.005 0.090 Open/Buried P210 Feedwater 32 3.11 1.22 TB 1
X 0.005 0.088 Open/Buried P211 Feedwater 32 3.11 1.22 TB 1
X 0.002 0.042 Open/Buried P212 Feedwater 32 3.11 1.22 TB 1
X 0.004 0.076 Open/Buried P217 Reactor Coolant to RHR Pumps 28 3.41 1.47 AUX 1
X 0.013 0.234 Removed P218 Cavity Fill Pump 1A Discharge 18 2.19 1.47 AUX 1
X 0.269 4.915 Removed P219 Component Cooling Water Supply 12 1.46 1.47 AUX 4
0.003 0.049 YES Removed P220 Cavity Fill Pump 1B Discharge 18 2.19 1.47 AUX 1
X 0.003 0.059 Removed P221 Spare 28 3.41 1.47 AUX 1
X 0.002 0.044 Removed P222 RHR Exchanger to RC Loop Cold Legs 28 3.41 1.47 AUX 1
X 0.363 6.631 Removed P223 RC Pumps to Cooling Pump Suction 12 1.46 1.47 AUX 4
0.350 6.387 YES Removed P235 Recirculating Sump Suction 23 28.53 15.6 AUX 50 0.395 7.203 YES Grouted P236 Cavity Flood Sump Suction 23 28.53 15.47 AUX 50 0.455 8.301 YES Grouted P237 Cavity Flood Sump Suction 23 28.53 15.49 AUX 50 0.375 6.842 YES Grouted P242 Sump Discharge to Floor Drain Tank 6
0.73 1.47 AUX 5
0.672 12.259 YES Removed P243 RC Drain Pump to Hold-Up Tank 8
0.97 1.47 AUX 5
0.154 2.803 YES Removed P250 Spare 10 1.22 1.47 AUX 5
0.140 2.563 YES Removed P254 Containment Pressure 6
0.73 1.47 AUX 4
0.469 8.570 YES Removed P256 Filtered Vents 8
0.97 1.47 AUX 5
0.194 3.545 YES Removed P264 Spare 8
0.97 1.47 AUX 5
0.013 0.234 YES Removed P266 RC Pump Seal Water Supply Lines 14 1.7 1.47 AUX 1
X 0.003 0.056 Removed P267 Spare 18 2.19 1.47 AUX 1
X 0.008 0.143 Removed P268 Aux Feedwater to Steam Gen 1C 14 1.7 1.47 AUX 1
X 0.003 0.050 Removed P269 Aux Feedwater to Steam Gen 1A 14 1.7 1.47 AUX 1
X 0.011 0.192 Removed P270 Cavity Drain to Purification Pump 14 1.7 1.47 AUX 1
X 0.803 14.658 Removed
~
= ZIONSOLUTIONSLLC-ME-v,,~~
FSS RELEASE RECORD, REV 1 PENETRATIONS SURVEY UNITS 01112, 02112 and 05120
[40]
Table 18 (continued) - Unit 2 Containment Penetrations Summary Pen.
No.
Description Diameter Surface Area Length Interface With
- of Measurements By Direct Scan Most Limiting DCGLs (1)
Require Grouting End-State Condition (in)
(m2)
(m)
OpSOFPN OpSOFB P273 Spare 18 2.19 1.47 AUX 1
X 0.019 0.347 Removed P274 Aux Feedwater to Steam Gen 1D 14 1.7 1.47 AUX 1
X 0.003 0.050 Removed P281 Non-Filtered Vents 8
0.97 1.47 AUX 5
0.505 9.223 YES Removed P286 RC Hot Leg Samples 10 1.22 1.47 AUX 4
0.574 10.474 YES Removed P287 Spare 10 1.22 1.47 AUX 5
0.217 3.953 YES Removed P288 Heating System Hot Water Supply 12 1.46 1.47 AUX 4
0.383 6.985 YES Removed P289 Heating System Hot Water Return 12 1.46 1.47 AUX 4
0.229 4.175 YES Removed P290 Spare 28 3.41 1.47 AUX 1
X 0.004 0.075 Removed P291 Blowdown Steam Generator 1A 16 1.56 1.22 TB 1
X 0.003 0.063 Open/Buried P292 Blowdown Steam Generator 1A 16 1.56 1.22 TB 1
X 0.004 0.066 Open/Buried P293 Blowdown Steam Generator 1C 16 1.56 1.22 TB 1
X 0.002 0.037 Open/Buried P294 Blowdown Steam Generator 1C 16 1.56 1.22 TB 1
X 0.001 0.027 Open/Buried P295 Blowdown Steam Generator 1A 14 1.36 1.22 TB 1
X 0.002 0.039 Open/Buried P296 Blowdown Steam Generator 1C 14 1.36 1.22 TB 1
X 0.003 0.047 Open/Buried P297 Blowdown Steam Generator 1D 14 1.36 1.22 TB 1
X 0.002 0.029 Open/Buried P298 Blowdown Steam Generator 1B 14 1.36 1.22 TB 1
X 0.002 0.031 Open/Buried P303 Spare 8
0.97 1.47 AUX 6
0.783 14.303 YES Removed P304 SIM to Aux F.S. Pumps 24 2.92 1.47 AUX 1
X 0.008 0.153 Removed P305 RHR to RC Loop Hot Legs 18 2.19 1.47 AUX 1
X 0.004 0.081 Removed P312 Steam Generator Blowdown Sample 16 1.56 1.22 TB 1
X 0.002 0.039 Open/Buried P313 Steam Generator Blowdown Sample 16 1.56 1.22 TB 1
X 0.002 0.029 Open/Buried P315 Blowdown (Steam Generator 1D) 16 1.56 1.22 TB 1
X 0.003 0.047 Open/Buried P316 Blowdown (Steam Generator 1D) 16 1.56 1.22 TB 1
X 0.003 0.049 Open/Buried P317 Blowdown (Steam Generator 1B) 16 1.56 1.22 TB 1
X 0.002 0.036 Open/Buried P318 Blowdown (Steam Generator 1B) 16 1.56 1.22 TB 1
X 0.002 0.040 Open/Buried P323 Recirculating Sump Suction 23 29.09 15.85 AUX 51 0.685 12.506 YES Grouted P324 Recirculating Sump Suction 23 29.65 16.1 AUX 50 0.444 8.106 YES Grouted P327 Steam to Aux FW Pumps 16 1.56 1.22 TB 1
X 0.004 0.075 Open/Buried P328 Steam to Aux FW Pumps 16 1.56 1.22 TB 1
X 0.002 0.032 Open/Buried (1) Compared against the most limiting OpDCGLPN (Table 8) and OpDCGLB (Table 15)
~
= ZIONSOLUTIONSLLC-ME-v,,~~
FSS RELEASE RECORD, REV 1 PENETRATIONS SURVEY UNITS 01112, 02112 and 05120
[41]
Table 19 - Summary of Unit 2 Containment Penetrations FSS Statistics Individual Measurement Metrics Total Number of Systematic Measurements = 369 Number of Quality Control Measurements = 20 Number of Judgmental/Investigational Measurements = 0 Total Number of Measurements = 389 Mean Systematic Measurement OpSOFPN = 0.142 Max Individual Systematic Measurement OpSOFPN = 0.803 Number of Systematic Measurements with OpSOF >1 = 0 ROC MEAN MEDIAN MAX MIN ST DEV BcDCGLPN BcSOFPN DOSE (pCi/m2)
(pCi/m2)
(pCi/m2)
(pCi/m2)
(pCi/m2)
(pCi/m2)
(mrem/yr)
H-3 3.75E+06 3.48E+06 2.12E+07 3.94E+04 2.80E+06 3.23E+09 0.001 0.029 Co-60 1.48E+05 1.37E+05 8.35E+05 1.55E+03 1.10E+05 8.82E+07 0.002 0.042 Ni-63 6.52E+07 6.05E+07 3.69E+08 6.85E+05 4.87E+07 5.48E+10 0.001 0.030 Sr-90 4.48E+04 4.15E+04 2.53E+05 4.70E+02 3.34E+04 1.94E+07 0.002 0.058 Cs-134 3.13E+02 2.90E+02 1.77E+03 3.28E+00 2.34E+02 3.28E+08 0.000 0.000 Cs-137 2.13E+06 1.98E+06 1.21E+07 2.24E+04 1.59E+06 5.29E+08 0.004 0.101 Eu-152 1.38E+04 1.28E+04 7.78E+04 1.44E+02 1.03E+04 3.29E+08 0.000 0.001 Eu-154 1.88E+03 1.74E+03 1.06E+04 1.97E+01 1.40E+03 2.33E+08 0.000 0.000 The mean BcSOF for Unit 2 Containment penetrations (survey unit 02112), when compared against the most-limiting BcDCGLPN is 0.010, which equates to a dose of 0.260 mrem/yr. In accordance with LTP, Section 6.4.5, the SOF of 0.010 or a dose value of 0.260 mrem/yr will be added to the Unit 2 Containment basement.
The OpSOF for 315 measurements in 22 penetrations that interfaced with Unit 2 Containment exceeded an OpSOF of one when compared against the most-limiting OpDCGLB for basement surfaces (Table 15). Consequently, in accordance with LTP, Section 5.5.5, the 22 penetrations cited would have required grouting. However, 17 of the 22 penetrations that exceeded the criteria were physically removed and disposed of as waste during building demolition. Only the remaining five (5) Unit 2 Containment Building Penetrations were actually grouted. No dose reduction was attributed to the survey unit because of grouting.
Table 20 provides the summary of the Auxiliary Building penetrations, a summary of the FSS results, and whether the penetration required grouting. Included are the penetrations that interface with the Turbine Building. The penetrations that are included in Unit 1 Containment (Table 16) and Unit 2 Containment (Table 18) are not included in the summary for the Auxiliary Building in Table 20. However, all penetrations that interface with the Auxiliary Building (Unit 1 Containment, Unit 2 Containment and the Turbine Building) are included in 730 measurements taken for the Auxiliary Building. The
~
=ZIONSOLlJTJONSLLc-
,..,ErawSCIMionlCompany
FSS RELEASE RECORD, REV 1 PENETRATIONS SURVEY UNITS 01112, 02112 and 05120
[42]
complete tables containing the measurement results of all Auxiliary Building measurements that were taken are presented in Attachment 2. The measurement data passed the Sign Test. The results of the Sign Test are provided in Attachment 3. The statistical summary of the measurement data taken, when compared against the most-limiting BcDCGLPN (Table 7) are presented in Table 21.
~
=ZIONSOLlJTJONSLLc-
,..,ErawSCIMionlCompany
FSS RELEASE RECORD, REV 1 PENETRATIONS SURVEY UNITS 01112, 02112 and 05120
[43]
Table 20 - Auxiliary Building Penetrations Summary Pen.
No.
Description Diameter Surface Area Length Interface With
- of Measurements By Direct Scan Most Limiting DCGLs (1)
Require Grouting End-State Condition (in)
(m2)
(m)
OpSOFPN OpSOFB A001 Service Water 22 1.65 0.91 TB 3
X 0.001 0.023 Open/Buried A002 Feedwater 4
0.29 0.91 TB 3
0.015 0.305 Open/Buried A003 Secondary Sample 2
0.15 0.91 TB 3
X 0.042 0.848 Open/Buried A004 Service Water 22 1.65 0.91 TB 3
0.001 0.021 Open/Buried A005 Feedwater 4
0.29 0.91 TB 3
0.012 0.250 Open/Buried A007 Vents and Drains 4
0.29 0.91 TB 3
0.013 0.254 Open/Buried A008 Vents and Drains 4
0.29 0.91 TB 3
0.015 0.311 Open/Buried A009 Waste Disposal 3
0.22 0.91 TB 3
0.013 0.262 Open/Buried A010 Service Water 10 0.73 0.91 TB 3
0.025 0.497 Open/Buried A011 Waste Disposal 2
0.15 0.91 TB 3
0.349 7.078 Yes Grouted A012 Chemical Addition 3
0.22 0.91 TB 3
0.017 0.346 Open/Buried A013 Primary Water 4
0.29 0.91 TB 3
0.021 0.421 Open/Buried A014 Service Water 18 1.37 0.91 TB 3
X 0.001 0.020 Open/Buried A015 Waste Disposal 6
0.44 0.91 TB 3
0.018 0.373 Open/Buried A017 Fire Protection 10 0.73 0.91 TB 3
0.031 0.636 Open/Buried A019 Primary Water 4
0.22 0.91 TB 3
0.013 0.256 Open/Buried A020 Vacuum Control 4
0.22 0.91 TB 3
0.015 0.296 Open/Buried A021 Demin Water 4
0.22 0.91 TB 3
0.016 0.330 Open/Buried A022 Primary Water 4
0.29 0.91 TB 3
0.015 0.298 Open/Buried A023 Waste Disposal 6
0.44 0.91 TB 3
0.206 4.181 Yes Grouted A024 Condensate 16 1.23 0.91 TB 3
X 0.003 0.066 Open/Buried A025 Service Water 34 2.52 0.91 TB 3
X 0.001 0.018 Open/Buried (1) Compared against the most limiting OpDCGLPN (Table 8) and OpDCGLB (Table 15)
~
= ZIONSOLlJTJONSLLc-
....,E-oySolifion,Cotnpwiy
FSS RELEASE RECORD, REV 1 PENETRATIONS SURVEY UNITS 01112, 02112 and 05120
[44]
Table 21 - Summary of Auxiliary Building Penetrations FSS Statistics Individual Measurement Metrics Total Number of Systematic Measurements = 730 Number of Quality Control Measurements = 5 Number of Judgmental/Investigational Measurements = 0 Total Number of Measurements = 735 Mean Systematic Measurement OpSOFPN = 0.405 Max Individual Systematic Measurement OpSOFPN = 10.082 Number of Systematic Measurements with OpSOF >1 = 45 ROC MEAN MEDIAN MAX MIN ST DEV BcDCGLPN BcSOFPN DOSE (pCi/m2)
(pCi/m2)
(pCi/m2)
(pCi/m2)
(pCi/m2)
(pCi/m2)
(mrem/yr)
H-3 1.06E+07 3.73E+06 2.67E+08 0.00E+00 3.15E+07 3.23E+09 0.003 0.082 Co-60 4.19E+05 1.47E+05 1.05E+07 2.71E+02 1.24E+06 8.82E+07 0.005 0.119 Ni-63 1.85E+08 6.48E+07 4.63E+09 4.88E+04 5.48E+08 5.48E+10 0.003 0.084 Sr-90 1.27E+05 4.45E+04 3.18E+06 4.43E+01 3.76E+05 1.94E+07 0.007 0.163 Cs-134 8.98E+02 3.12E+06 2.22E+04 2.94E+00 2.63E+03 3.28E+08 0.000 0.000 Cs-137 6.13E+06 2.13E+06 1.51E+08 2.22E+04 1.79E+07 5.29E+08 0.012 0.290 Eu-152 3.89E+04 1.37E+04 9.77E+05 0.00E+00 1.16E+05 3.29E+08 0.000 0.003 Eu-154 5.31E+03 1.87E+03 1.33E+05 0.00E+00 1.58E+04 2.33E+08 0.000 0.001 The mean BcSOF for Auxiliary Building penetrations (survey unit 05120), when compared against the most-limiting BcDCGLPN is 0.030, which equates to a dose of 0.742 mrem/yr.
The same 45 measurements that exceeded the most-limiting OpDCGLPN but were less than the BcDCGLPN in Unit 1 Containment also impacts the Auxiliary Building. The mean BcSOF for the Auxiliary Building was also adjusted to include the dose from the same elevated measurements using Equation 5-6 from LTP, Section 5.5.5, reproduced as Equation 2. The mean BcSOF for the survey unit was then adjusted by adding the SOF from the elevated areas to the mean to account for the additional dose attributed to the elevated areas.
The calculation to derive the adjustment to the mean BcSOF is presented in Attachment 2.
In accordance with LTP, Table 6-50, the adjusted surface area of the Unit 1 Containment Penetrations FSS unit (SASU) was 948.75 m2. The surface area of each of the elevated measurements was 0.559 m2, which equates to the FOV of each individual static measurement. The individual elevated SOF for each elevated ROC were than summed to provide a total SOF adjustment due to each of the 45 elevated measurements.
The mean BcSOF for the Auxiliary Building penetrations was adjusted by a value of 0.007 to account for the identified elevated measurements. The adjusted mean BcSOF for the Auxiliary Building penetrations was 0.037, which equated to the dose assigned to the
~
=ZIONSOLlJTJONSLLc-
,..,ErawSCIMionlCompany
FSS RELEASE RECORD, REV 1 PENETRATIONS SURVEY UNITS 01112, 02112 and 05120
[45]
survey unit of 0.927 mrem/yr. This value is the dose assigned to the survey unit based on the average of the systematic measurements adjusted for the dose contribution of the identified elevated measurements. In accordance with LTP, Section 6.4.5, the SOF of 0.037 or a dose value of 0.927 mrem/yr will be added to the Auxiliary Building basement.
The OpSOF for 632 measurements in 53 penetrations that interfaced with the Auxiliary Building exceeded an OpSOF of one when compared against the most-limiting OpDCGLB for basement surfaces (Table 15). Consequently, in accordance with LTP, Section 5.5.5, the 53 penetrations cited would have required grouting. However, 51 of the 53 penetrations that exceeded the criteria were accounted for in the assessment of Unit 1 and Unit 2 Containment penetrations. The remaining 2 Auxiliary Building penetrations were actually grouted. No dose reduction was attributed to the survey unit because of grouting.
All penetrations that interface with the Turbine Building are captured in the summary lists for the Containment (Tables 16 and 18) and the Auxiliary Building (Table 20). All penetrations that interface with the Turbine Building (Unit 1 Containment, Unit 2 Containment and the Auxiliary Building) are included in 115 measurements taken for the Turbine Building. The complete tables containing the measurement results of all Turbine Building measurements that were taken are presented in Attachment 2. The measurement data passed the Sign Test. The results of the Sign Test are provided in Attachment 3. The statistical summary of the measurement data taken, when compared against the most-limiting BcDCGLPN (Table 7) are presented in Table 22.
~
=ZIONSOLlJTJONSLLc-
,..,ErawSCIMionlCompany
FSS RELEASE RECORD, REV 1 PENETRATIONS SURVEY UNITS 01112, 02112 and 05120
[46]
Table 22 - Summary of Turbine Building Penetrations FSS Statistics Individual Measurement Metrics Total Number of Systematic Measurements = 115 Number of Quality Control Measurements = 5 Number of Judgmental/Investigational Measurements = 0 Total Number of Measurements = 120 Mean Systematic Measurement OpSOFPN = 0.021 Max Individual Systematic Measurement OpSOFPN = 0.349 Number of Systematic Measurements with OpSOF >1 = 0 ROC MEAN MEDIAN MAX MIN ST DEV BcDCGLPN BcSOFPN DOSE (pCi/m2)
(pCi/m2)
(pCi/m2)
(pCi/m2)
(pCi/m2)
(pCi/m2)
(mrem/yr)
H-3 3.57E+04 0.00E+00 2.09E+05 0.00E+00 4.98E+04 3.23E+09 0.000 0.000 Co-60 9.29E+03 4.51E+03 1.43E+05 2.71E+02 2.27E+04 8.82E+07 0.000 0.003 Ni-63 2.04E+06 1.06E+06 2.59E+07 4.88E+04 4.05E+06 5.48E+10 0.000 0.001 Sr-90 1.72E+03 8.65E+02 2.35E+04 4.43E+01 3.69E+03 1.94E+07 0.000 0.002 Cs-134 8.87E+01 1.09E+01 1.56E+03 2.94E+00 2.51E+02 3.28E+08 0.000 0.000 Cs-137 6.66E+05 7.43E+04 1.17E+07 2.09E+04 1.89E+06 5.29E+08 0.001 0.031 Eu-152 1.31E+02 0.00E+00 7.68E+02 0.00E+00 1.83E+02 3.29E+08 0.000 0.000 Eu-154 1.78E+01 0.00E+00 1.05E+02 0.00E+00 2.49E+01 2.33E+08 0.000 0.000 The mean BcSOF for Turbine Building penetrations, when compared against the most-limiting BcDCGLPN is 0.002, which equates to a dose of 0.038 mrem/yr. In accordance with LTP, Section 6.4.5, the SOF of 0.002 or a dose value of 0.038 mrem/yr will be added to the Turbine Building basement.
- 8.
QUALITY CONTROL In compliance with ZS-LT-01, replicate measurements were performed on 5% of the survey locations chosen at random. Nineteen (19) replicate measurements were taken in penetrations that interfaced with Unit 1 Containment, 20 replicate measurements were taken in penetrations that interfaced with Unit 2 Containment and 5 replicate measurements were taken in penetrations that interfaced with the Auxiliary Building. A total of 44 replicate measurements were taken, which equates to 5% of the total number of measurements and satisfies the requirement. Using the acceptance criteria specified in section 4.1.2 of ZS-LT-01, there was acceptable agreement between the replicate readings and the original readings. Refer to Attachment 5 for QC analysis results.
~
=ZIONSOLlJTJONSLLc-
,..,ErawSCIMionlCompany
FSS RELEASE RECORD, REV 1 PENETRATIONS SURVEY UNITS 01112, 02112 and 05120
[47]
- 9.
INVESTIGATIONS AND RESULTS No investigations were performed during the performance or analyses of the FSS.
- 10.
REMEDIATION AND RESULTS No radiological remedial action as described by MARSSIM Section 5.4 was performed in this survey unit prior to or as a result of the FSS.
The FSS of the Unit 1 Containment and Unit 2 Containment penetrations was performed prior to the demolition of the Unit 1 and Unit 2 Containment domes to the 588-foot elevation. During the course of the demolition, the walls of both Containment Buildings that interfaced with the Auxiliary Building was completely removed and disposed of, including the wall surfaces where they were located. No dose was subtracted from the survey unit due to this action.
- 11.
CHANGES FROM THE FINAL STATUS SURVEY PLAN There were no addendums to the FSS plan.
- 12.
DATA QUALITY ASSESSMENT (DQA)
The DQO sample design and data were reviewed in accordance with ZionSolutions procedure ZS-LT-300-001-004, Final Status Survey Data Assessment for completeness and consistency. Documentation was complete and legible. Surveys and measurement collection were consistent with the DQOs and were sufficient to ensure that the survey unit was properly classified.
The Sign Test was performed on the data and compared to the original assumptions of the DQOs. The evaluation of the Sign Test results clearly demonstrates that the survey unit passes the unrestricted release criteria, thus, the null hypothesis is rejected.
The preliminary data review consisted of calculating basic statistical quantities (e.g., mean, median, standard deviation). All data was considered valid including negative values, zeros, values reported below the MDC, and values with uncertainties greater than two standard deviations. The mean and median values for each ROC were well below the respective OpDCGLPN. Therefore, the survey unit meets the unrestricted release criteria with adequate power as required by the DQOs.
The data for Co-60 and Cs-137 is represented graphically through a frequency plot and a quantile plot. All graphical representations are provided in Attachment 5.
~
=ZIONSOLlJTJONSLLc-
,..,ErawSCIMionlCompany
FSS RELEASE RECORD, REV 1 PENETRATIONS SURVEY UNITS 01112, 02112 and 05120
[48]
- 13.
ANOMALIES No anomalies were observed during the performance or analyses of the survey.
- 14.
CONCLUSION The FSS of penetration survey unit 01112 (Unit 1 Containment), 02112 (Unit 2 Containment) and survey unit 05120 (Auxiliary Building) has met the DQOs of the FSS plan. The ALARA criteria as specified in Chapter 4 of the LTP were achieved. The Elevated Measurement Comparison (EMC) is not applicable to structural surfaces.
All penetration survey units were properly classified as Class 1. All identified ROC was used for statistical testing to determine the adequacy of the survey unit for FSS. Fourteen-hundred and sixty-eight (1468) measurements were obtained. Evaluation of the data shows that none of the ROC concentration values exceed the OpDCGLPN or any investigational levels in 1423 of the 1468 measurements taken. Forty-five (45) measurements exceeded the most-limiting OpDCGLPN but were less than the most-limiting BcDCGLPN. The OpSOF (based on the OpDCGL) for a systematic or a judgmental measurement(s) may exceed one without remediation as long as the survey unit passes the Sign Test and, the mean OpSOF (based on the OpDCGL) for the survey unit does not exceed one. For each of the penetration survey units, the Sign Test was passed. Table 23 presents the mean OpSOFPN for each penetration survey unit.
Table 23 - Summary of Mean OpSOFPN for Penetration FSS Penetration Survey Unit Mean OpSOFPN Unit 1 Containment 0.661 Unit 2 Containment 0.142 Auxiliary Building 0.405 Turbine Building (1) 0.021 (1) The Turbine Building is a survey unit through interface only. The penetrations that interface the Turbine Building are accounted for in the lists for the Containments and Auxiliary Building LTP, Section 5.5.5 requires that the dose from elevated measurements be added to the mean dose for the survey unit affected. Forty-five (45) measurements exceeded the OpDCGLPN in penetrations that interfaced between the Containment and the Auxiliary Building.
Consequently, the mean BcSOF for Unit 1 Containment was adjusted by a value of 0.053, and the mean BcSOF for the Auxiliary Building was adjusted by a value of 0.007 to account for the identified elevated measurements. These values were then added to the mean BcSOF of 0.048 for the Unit 1 Containment penetration and the mean BcSOF of 0.030 for the Auxiliary Building. Table 24 presents the mean BcSOFPN for each penetration survey
~
=ZIONSOLlJTJONSLLc-
,..,ErawSCIMionlCompany
FSS RELEASE RECORD, REV 1 PENETRATIONS SURVEY UNITS 01112, 02112 and 05120
[49]
unit, adjusted as required to account for the elevated measurements, and the derived dose for each.
Table 24 - Summary of Mean BcSOFPN and Mean Dose for Penetration FSS Penetration Survey Unit Mean BcSOFPN Dose (mrem/yr)
Unit 1 Containment 0.101 2.537 Unit 2 Containment 0.010 0.260 Auxiliary Building 0.037 0.927 Turbine Building (1) 0.002 0.038 LTP, Section 6.4.5 requires that the dose from a penetration be added to each basement that the penetration interfaces with. The values listed in Table 24 will be added to each basement as applicable.
The null hypothesis was rejected. Therefore, in accordance with the LTP Section 5.10, survey units 01112 (Unit 1 Containment), 02112 (Unit 2 Containment) and 05120 (Auxiliary Building) meet the release criterion and are acceptable for unrestricted release.
- 15.
REFERENCES
- 1. ZionSolutions procedure ZS-LT-300-001-005, Final Status Survey Data Reporting
- 2. Zion Station Restoration Project License Termination Plan
- 3. ZionSolutions procedure ZS-LT-300-001-001, Final Status Survey Package Development
- 4. NUREG-1575, Multi-Agency Radiation Survey and Site Investigation Manual
- 5. ZionSolutions TSD 14-016, Description of Embedded Piping, Penetrations, and Buried Pipe to Remain in Zion End State
- 6. ZionSolutions procedure ZS-LT-300-001-002, Survey Unit Classification
- 7. Zion Station Historical Site Assessment
- 8. ZionSolutions TSD 14-028, Radiological Characterization Report
- 9. ZionSolutions TSD 11-001, Technical Support Document for Potential Radionuclides of Concern During the Decommissioning of the Zion Station
- 10. ZionSolutions TSD 17-004, Operational Derived Concentration Guideline Levels for Final Status Survey
- 11. ZionSolutions TSD 14-019, Radionuclides of Concern for Soil and Basement Fill Model Source Terms
~
=ZIONSOLlJTJONSLLc-
,..,ErawSCIMionlCompany
FSS RELEASE RECORD, REV 1 PENETRATIONS SURVEY UNITS 01112, 02112 and 05120
[50]
- 12. ZionSolutions ZS-LT-01, Quality Assurance Project Plan (for Characterization and FSS)
- 13. ZionSolutions procedure ZS-LT-300-001-003, Isolation and Control for Final Status Survey
- 14. ZionSolutions procedure ZS-LT-300-001-006, Radiation Surveys of Pipe Interiors Using Sodium/Cesium Iodide Detectors
- 15. ZionSolutions procedure ZS-LT-300-001-004, Final Status Survey Data Assessment
- 16.
ATTACHMENTS
- Figures and Maps
- Measurement Data
- Sign Test
- QC Measurement Assessments
- Graphical Presentations
~
=ZIONSOLlJTJONSLLc-
,..,ErawSCIMionlCompany
[51]
ATTACHMENT 1 FIGURES AND MAPS
FSS RELEASE RECORD, REV 1 PENETRATIONS SURVEY UNITS 01112, 02112 and 05120
[52]
Figure 1 - Unit 1 Containment Penetrations o Penetrations
-+
I I
I I
I I
--G-
~
= ZlONSOLlJTJONSLLc-
...,,~~eomp.ny Unit 1 Containment Building Penetrations Final Status Survey Date: 1210512011
FSS RELEASE RECORD, REV 1 PENETRATIONS SURVEY UNITS 01112, 02112 and 05120
[53]
Figure 2 - Unit 1 Containment Penetrations - Interface with West Main Steam Valve House 116 0 115 0 11 0 P0970 P118 P117Q 0 120 O P008 P098 Q O P113 0
O P128 P007 0 Penetrations
~
= ZlONSOLlJTJONSLLc-Unit 1 Containment I
I I
I I
~
Li o~
I ~
...,,~~eomp.ny
FSS RELEASE RECORD, REV 1 PENETRATIONS SURVEY UNITS 01112, 02112 and 05120
[54]
Figure 3 - Unit 1 Containment Penetrations - Interface with East Main Steam Valve House o Penetrations P0060 Q P112 0940 Q P096Q Q P127 P095Q 0 093 0 10 0
P005 009 0
092 0
P091 Unit 1 Containment I
I
FSS RELEASE RECORD, REV 1 PENETRATIONS SURVEY UNITS 01112, 02112 and 05120
[55]
Figure 4 - Unit 1 Containment Penetrations - Interface with Auxiliary Building Note - This entire wall where these penetrations were located was removed and disposed of as waste after FSS was completed.
0 P049 P004Q 0 P104 P0030 Q
P050 0
P090 0
P087 P1030 0 0 P022 P068O 0
P021 P056 0
PO?oO O
Po20 P066 0
P0420 0
P018 P105 0
Poo1 0 P073 Q o 4 P04p 0 0
P017 P069 P081Q P0670 q,o 4 P 64 0
0, 89
~
= ZlONSOLlJTJONSLLc-
...,,~~eomp.ny 0 Penetrations Unit 1 Containment
FSS RELEASE RECORD, REV 1 PENETRATIONS SURVEY UNITS 01112, 02112 and 05120
[56]
Figure 5 - Unit 1 Containment Penetrations - Cavity Flood Sump and Recirculating Sump Suction
~
ZIONSOLUTIONS---
...,,~~eomp.ny lLC P035 P036 Unit 1 Containment P037 1
FSS RELEASE RECORD, REV 1 PENETRATIONS SURVEY UNITS 01112, 02112 and 05120
[57]
Figure 6 - Unit 2 Containment Penetrations
--~--------------
~
= ZlONSOLlJTJONSLLc-
...,,~~eomp.ny Unit 2 Containment Building Penetrations Final Status Survey Date: 1210S12011
FSS RELEASE RECORD, REV 1 PENETRATIONS SURVEY UNITS 01112, 02112 and 05120
[58]
Figure 7 - Unit 2 Containment Penetrations - Interface with West Main Steam Valve House P3180 Q 317 P2 0
P208 O 0 P298 P313 o Penetrations 0
cf297 0
P328 207
~
=ZlONSOLJ!Il!2MllC-Unit 2 Containment U---
0
FSS RELEASE RECORD, REV 1 PENETRATIONS SURVEY UNITS 01112, 02112 and 05120
[59]
Figure 8 - Unit 2 Containment Penetrations - Interface with East Main Steam Valve House o Penetrations OP206 P312 Q Q P296 Q P29 0
P327Q O
P29 Q P295 p2 P205O 0P209 0 Op29
~
= ZlONSOLlJTJONSLLc-
...,,~~eomp.ny Unit 2 Containment 10
FSS RELEASE RECORD, REV 1 PENETRATIONS SURVEY UNITS 01112, 02112 and 05120
[60]
Figure 9 - Unit 2 Containment Penetrations - Interface with Auxiliary Building Note - This entire wall where these penetrations were located was removed and disposed of as waste after FSS was completed.
- ------------() --------------------
P249 p 40 0 P2g()
P290 0
P287 0 0 Op303 P222 P221 0
0 P268 0
P256 P220 0
0 P266 P218 0
Op242 0
P305 P Q p273 0 P201 0
q,243 P217 0
O P269 P281
~
= ZlONSOLlJTJONSLLc-
...,,~~eomp.ny 0 Penetrations Unit 2 Containment
FSS RELEASE RECORD, REV 1 PENETRATIONS SURVEY UNITS 01112, 02112 and 05120
[61]
Figure 10 - Unit 2 Containment Penetrations - Cavity Flood Sump and Recirculating Sump Suction
~
= ZlONSOLlJTJONSLLc-
...,,~~eomp.ny P235 Unit 2 Containment P237
\\
_J
FSS RELEASE RECORD, REV 1 PENETRATIONS SURVEY UNITS 01112, 02112 and 05120
[62]
Figure 11 - Auxiliary Building Penetrations 30 column I
I I
!;-:"'-.-o,o I,.,,
I I
I i
542' I I
I C
10 11 12 13 14 15 0
Relative Penetration Location I
I
.I,,
I I
)-~.. :Iii i I
M114-h,O,.11 !
i I
I I
I I
16 17 18 GWall 20 I
22 I
23 I
I I
I I
I I
24 26 27 I
29
~
= ZlONSOLlJTJONSLLc-
...,,~~eomp.ny 571' 54z~,---,---~----',
L C
Jz ~ ~-
Z1o~S0Lur1oss
- Auxiliary Building Penetrations Final Status Survey Date: 12/06/2017
[63]
ATTACHMENT 2 MEASUREMENT DATA
FSS RELEASE RECORD, REV 1 PENETRATIONS SURVEY UNITS 01112, 02112 and 05120
[64]
Unit 1 Containment Penetration Measurements H-3 (1)
Co-60 (2)
Ni-63 (1)
Sr-90 (1)
Cs-134 (2)
Cs-137 (2)
Eu-152 (2)
Eu-154 (2)
OpSOFPN OpSOFPN OpSOFB OpSOFB (pCi/m2)
(pCi/m2)
(pCi/m2)
(pCi/m2)
(pCi/m2)
(pCi/m2)
(pCi/m2)
(pCi/m2)
CTMTPN Limiting DCGL CTMT DCGL Limiting DCGL P001 Position #1 CTMT AUX Removed 1.06E+07 4.18E+05 1.85E+08 1.27E+05 8.86E+02 6.04E+06 3.90E+04 5.31E+03 0.343 0.402 2.451 7.339 P001 Position #2 CTMT AUX Removed 2.96E+06 1.16E+05 5.14E+07 3.53E+04 2.46E+02 1.68E+06 1.08E+04 1.48E+03 0.095 0.112 0.682 2.042 P001 Position #3 CTMT AUX Removed 1.77E+06 6.98E+04 3.08E+07 2.12E+04 1.48E+02 1.01E+06 6.51E+03 8.87E+02 0.057 0.067 0.409 1.225 P001 Position #4 CTMT AUX Removed 1.62E+06 6.37E+04 2.82E+07 1.93E+04 1.35E+02 9.21E+05 5.94E+03 8.10E+02 0.052 0.061 0.374 1.119 P001 Position #5 CTMT AUX Removed 3.08E+06 1.21E+05 5.35E+07 3.67E+04 2.56E+02 1.75E+06 1.13E+04 1.54E+03 0.099 0.116 0.709 2.124 P086 Position #1 CTMT AUX Removed 2.48E+06 9.77E+04 4.32E+07 2.96E+04 2.07E+02 1.41E+06 9.11E+03 1.24E+03 0.080 0.094 0.573 1.715 P086 Position #2 CTMT AUX Removed 7.87E+06 3.10E+05 1.37E+08 9.39E+04 6.56E+02 4.47E+06 2.89E+04 3.94E+03 0.254 0.298 1.816 5.437 P086 Position #3 CTMT AUX Removed 2.06E+06 8.11E+04 3.58E+07 2.46E+04 1.72E+02 1.17E+06 7.56E+03 1.03E+03 0.067 0.078 0.475 1.424 P086 Position #4 CTMT AUX Removed 1.51E+06 5.93E+04 2.62E+07 1.80E+04 1.26E+02 8.56E+05 5.53E+03 7.54E+02 0.049 0.057 0.348 1.041 P086 Position #5 CTMT AUX Removed 1.62E+06 6.38E+04 2.82E+07 1.94E+04 1.35E+02 9.22E+05 5.95E+03 8.11E+02 0.052 0.061 0.374 1.120 P019 Position #1 CTMT AUX Removed 7.00E+06 2.75E+05 1.22E+08 8.35E+04 5.83E+02 3.97E+06 2.57E+04 3.50E+03 0.226 0.265 1.613 4.831 P019 Position #2 CTMT AUX Removed 2.13E+06 8.39E+04 3.71E+07 2.54E+04 1.78E+02 1.21E+06 7.82E+03 1.07E+03 0.069 0.081 0.492 1.473 P019 Position #3 CTMT AUX Removed 1.48E+06 5.83E+04 2.58E+07 1.77E+04 1.23E+02 8.42E+05 5.43E+03 7.41E+02 0.048 0.056 0.342 1.023 P019 Position #4 CTMT AUX Removed 1.38E+06 5.42E+04 2.39E+07 1.64E+04 1.15E+02 7.82E+05 5.05E+03 6.88E+02 0.044 0.052 0.317 0.951 P019 Position #5 CTMT AUX Removed 1.53E+06 6.03E+04 2.66E+07 1.83E+04 1.28E+02 8.70E+05 5.62E+03 7.66E+02 0.049 0.058 0.353 1.058 P023 Position #1 CTMT AUX Removed 9.94E+06 3.91E+05 1.73E+08 1.19E+05 8.28E+02 5.65E+06 3.64E+04 4.97E+03 0.321 0.376 2.291 6.862 P023 Position #2 CTMT AUX Removed 2.39E+06 9.41E+04 4.16E+07 2.85E+04 1.99E+02 1.36E+06 8.77E+03 1.20E+03 0.077 0.090 0.551 1.651 P023 Position #3 CTMT AUX Removed 1.57E+06 6.18E+04 2.73E+07 1.87E+04 1.31E+02 8.92E+05 5.76E+03 7.85E+02 0.051 0.059 0.362 1.084 P023 Position #4 CTMT AUX Removed 1.51E+06 5.94E+04 2.63E+07 1.80E+04 1.26E+02 8.58E+05 5.54E+03 7.55E+02 0.049 0.057 0.348 1.043 P023 Position #5 CTMT AUX Removed 1.94E+06 7.63E+04 3.37E+07 2.31E+04 1.62E+02 1.10E+06 7.11E+03 9.70E+02 0.063 0.073 0.447 1.339 P088 Position #1 CTMT AUX Removed 6.16E+06 2.42E+05 1.07E+08 7.34E+04 5.13E+02 3.50E+06 2.26E+04 3.08E+03 0.199 0.233 1.419 4.251 P088 Position #2 CTMT AUX Removed 2.02E+06 7.94E+04 3.51E+07 2.41E+04 1.68E+02 1.15E+06 7.41E+03 1.01E+03 0.065 0.076 0.466 1.395 P088 Position #3 CTMT AUX Removed 1.58E+06 6.21E+04 2.74E+07 1.88E+04 1.32E+02 8.97E+05 5.79E+03 7.89E+02 0.051 0.060 0.364 1.090 P088 Position #4 CTMT AUX Removed 1.47E+06 5.77E+04 2.55E+07 1.75E+04 1.22E+02 8.33E+05 5.38E+03 7.34E+02 0.047 0.055 0.338 1.013 P088 Position #5 CTMT AUX Removed 1.74E+06 6.86E+04 3.03E+07 2.08E+04 1.45E+02 9.91E+05 6.40E+03 8.73E+02 0.056 0.066 0.402 1.205 P089 Position #1 CTMT AUX Removed 8.09E+06 3.18E+05 1.41E+08 9.66E+04 6.75E+02 4.60E+06 2.97E+04 4.05E+03 0.261 0.306 1.867 5.590 P089 Position #2 CTMT AUX Removed 2.83E+06 1.11E+05 4.92E+07 3.37E+04 2.36E+02 1.61E+06 1.04E+04 1.41E+03 0.091 0.107 0.652 1.953 P089 Position #3 CTMT AUX Removed 1.87E+06 7.37E+04 3.26E+07 2.24E+04 1.56E+02 1.06E+06 6.87E+03 9.37E+02 0.060 0.071 0.432 1.294 P089 Position #4 CTMT AUX Removed 1.62E+06 6.36E+04 2.81E+07 1.93E+04 1.35E+02 9.18E+05 5.92E+03 8.08E+02 0.052 0.061 0.373 1.116 P089 Position #5 CTMT AUX Removed 2.16E+06 8.52E+04 3.76E+07 2.58E+04 1.80E+02 1.23E+06 7.94E+03 1.08E+03 0.070 0.082 0.499 1.495 P004 Position #1 CTMT AUX Removed 8.59E+06 3.38E+05 1.49E+08 1.02E+05 7.16E+02 4.88E+06 3.15E+04 4.29E+03 0.277 0.325 1.981 5.931 P004 Position #2 CTMT AUX Removed 1.75E+06 6.89E+04 3.04E+07 2.09E+04 1.46E+02 9.95E+05 6.42E+03 8.75E+02 0.056 0.066 0.404 1.209 P004 Position #3 CTMT AUX Removed 1.54E+06 6.06E+04 2.68E+07 1.84E+04 1.28E+02 8.76E+05 5.65E+03 7.71E+02 0.050 0.058 0.355 1.064 P004 Position #4 CTMT AUX Removed 1.60E+06 6.29E+04 2.78E+07 1.91E+04 1.33E+02 9.08E+05 5.86E+03 7.99E+02 0.052 0.060 0.369 1.104 P004 Position #5 CTMT AUX Removed 1.79E+06 7.05E+04 3.12E+07 2.14E+04 1.49E+02 1.02E+06 6.57E+03 8.96E+02 0.058 0.068 0.413 1.237 P042 Position #1 CTMT AUX Removed 8.00E+06 3.15E+05 1.39E+08 9.54E+04 6.66E+02 4.54E+06 2.93E+04 4.00E+03 0.258 0.302 1.844 5.522 P042 Position #2 CTMT AUX Removed 2.95E+06 1.16E+05 5.14E+07 3.53E+04 2.46E+02 1.68E+06 1.08E+04 1.48E+03 0.095 0.112 0.681 2.041 P042 Position #3 CTMT AUX Removed 2.69E+06 1.06E+05 4.68E+07 3.21E+04 2.24E+02 1.53E+06 9.86E+03 1.35E+03 0.087 0.102 0.620 1.858 P042 Position #4 CTMT AUX Removed 1.55E+06 6.09E+04 2.69E+07 1.85E+04 1.29E+02 8.79E+05 5.67E+03 7.74E+02 0.050 0.059 0.357 1.068 P042 Position #5 CTMT AUX Removed 3.18E+06 1.25E+05 5.52E+07 3.79E+04 2.65E+02 1.80E+06 1.16E+04 1.59E+03 0.102 0.120 0.733 2.194 P043 Position #1 CTMT AUX Removed 8.10E+06 3.18E+05 1.41E+08 9.66E+04 6.75E+02 4.60E+06 2.97E+04 4.05E+03 0.261 0.306 1.867 5.591 P043 Position #2 CTMT AUX Removed 1.96E+06 7.69E+04 3.40E+07 2.33E+04 1.63E+02 1.11E+06 7.17E+03 9.78E+02 0.063 0.074 0.451 1.351 P043 Position #3 CTMT AUX Removed 2.04E+06 8.03E+04 3.55E+07 2.44E+04 1.70E+02 1.16E+06 7.49E+03 1.02E+03 0.066 0.077 0.471 1.410 P043 Position #4 CTMT AUX Removed 2.29E+06 9.00E+04 3.98E+07 2.73E+04 1.91E+02 1.30E+06 8.39E+03 1.14E+03 0.074 0.087 0.528 1.581 P043 Position #5 CTMT AUX Removed 3.83E+06 1.51E+05 6.67E+07 4.57E+04 3.20E+02 2.18E+06 1.41E+04 1.92E+03 0.124 0.145 0.884 2.648 P054 Position #1 CTMT AUX Removed 7.30E+06 2.87E+05 1.27E+08 8.71E+04 6.08E+02 4.15E+06 2.68E+04 3.65E+03 0.236 0.276 1.684 5.042 P054 Position #2 CTMT AUX Removed 1.66E+06 6.55E+04 2.89E+07 1.99E+04 1.39E+02 9.46E+05 6.10E+03 8.32E+02 0.054 0.063 0.384 1.149 P054 Position #3 CTMT AUX Removed 1.73E+06 6.82E+04 3.01E+07 2.07E+04 1.45E+02 9.85E+05 6.36E+03 8.67E+02 0.056 0.066 0.400 1.197 P054 Position #4 CTMT AUX Removed 2.06E+06 8.09E+04 3.57E+07 2.45E+04 1.71E+02 1.17E+06 7.54E+03 1.03E+03 0.066 0.078 0.474 1.419 P054 Position #5 CTMT AUX Removed 2.19E+06 8.60E+04 3.80E+07 2.61E+04 1.82E+02 1.24E+06 8.02E+03 1.09E+03 0.071 0.083 0.504 1.509 P081 Position #1 CTMT AUX Removed 6.20E+06 2.44E+05 1.08E+08 7.40E+04 5.17E+02 3.53E+06 2.28E+04 3.10E+03 0.200 0.235 1.431 4.285 P081 Position #2 CTMT AUX Removed 1.87E+06 7.36E+04 3.25E+07 2.23E+04 1.56E+02 1.06E+06 6.86E+03 9.35E+02 0.060 0.071 0.431 1.291 P081 Position #3 CTMT AUX Removed 1.79E+06 7.03E+04 3.11E+07 2.13E+04 1.49E+02 1.02E+06 6.56E+03 8.94E+02 0.058 0.068 0.412 1.234 MEASUREMENT ID BETWEEN END STATE
~
=ZIONSOLUTIONSuc-An Er,e,,gyS~ Company I
I I
I I
I I
I I
I I
I I
I I
I I
I I
I I
I I
I I
I I
I I
FSS RELEASE RECORD, REV 1 PENETRATIONS SURVEY UNITS 01112, 02112 and 05120
[65]
Unit 1 Containment Penetration Measurements (continued)
H-3 (1)
Co-60 (2)
Ni-63 (1)
Sr-90 (1)
Cs-134 (2)
Cs-137 (2)
Eu-152 (2)
Eu-154 (2)
OpSOFPN OpSOFPN OpSOFB OpSOFB (pCi/m2)
(pCi/m2)
(pCi/m2)
(pCi/m2)
(pCi/m2)
(pCi/m2)
(pCi/m2)
(pCi/m2)
CTMTPN Limiting DCGL CTMT DCGL Limiting DCGL P081 Position #4 CTMT AUX Removed 1.85E+06 7.26E+04 3.21E+07 2.20E+04 1.54E+02 1.05E+06 6.77E+03 9.23E+02 0.060 0.070 0.425 1.274 P081 Position #5 CTMT AUX Removed 2.62E+06 1.03E+05 4.56E+07 3.13E+04 2.19E+02 1.49E+06 9.61E+03 1.31E+03 0.085 0.099 0.605 1.811 P104 By Direct Scan CTMT AUX Removed 1.08E+05 4.26E+03 1.88E+06 1.29E+03 9.03E+00 6.16E+04 3.97E+02 5.42E+01 0.003 0.004 0.025 0.075 P022 By Direct Scan CTMT AUX Removed 1.03E+06 4.07E+04 1.80E+07 1.23E+04 8.62E+01 5.87E+05 3.79E+03 5.17E+02 0.033 0.039 0.238 0.714 P074 By Direct Scan CTMT AUX Removed 9.40E+04 3.70E+03 1.63E+06 1.12E+03 7.83E+00 5.34E+04 3.45E+02 4.70E+01 0.003 0.004 0.022 0.065 P123 Position #1 CTMT AUX Grouted 2.13E+08 8.37E+06 3.70E+09 2.54E+06 1.77E+04 1.21E+08 7.80E+05 1.06E+05 6.864 8.048 49.060 146.918 P123 Position #2 CTMT AUX Grouted 2.42E+08 9.53E+06 4.21E+09 2.89E+06 2.02E+04 1.38E+08 8.89E+05 1.21E+05 7.819 9.166 55.878 167.337 P123 Position #3 CTMT AUX Grouted 2.67E+08 1.05E+07 4.63E+09 3.18E+06 2.22E+04 1.51E+08 9.77E+05 1.33E+05 8.600 10.082 61.460 184.052 P123 Position #4 CTMT AUX Grouted 2.58E+08 1.01E+07 4.48E+09 3.07E+06 2.15E+04 1.46E+08 9.44E+05 1.29E+05 8.310 9.743 59.392 177.860 P123 Position #5 CTMT AUX Grouted 2.37E+08 9.31E+06 4.11E+09 2.82E+06 1.97E+04 1.34E+08 8.68E+05 1.18E+05 7.635 8.951 54.568 163.414 P123 Position #6 CTMT AUX Grouted 2.10E+08 8.25E+06 3.65E+09 2.50E+06 1.75E+04 1.19E+08 7.69E+05 1.05E+05 6.764 7.930 48.342 144.768 P123 Position #7 CTMT AUX Grouted 1.96E+08 7.71E+06 3.41E+09 2.34E+06 1.63E+04 1.11E+08 7.18E+05 9.80E+04 6.321 7.411 45.178 135.294 P123 Position #8 CTMT AUX Grouted 1.83E+08 7.21E+06 3.19E+09 2.19E+06 1.53E+04 1.04E+08 6.72E+05 9.17E+04 5.915 6.935 42.274 126.597 P123 Position #9 CTMT AUX Grouted 1.73E+08 6.80E+06 3.01E+09 2.06E+06 1.44E+04 9.83E+07 6.34E+05 8.65E+04 5.581 6.543 39.886 119.446 P123 Position #10 CTMT AUX Grouted 1.84E+08 7.26E+06 3.21E+09 2.20E+06 1.54E+04 1.05E+08 6.76E+05 9.22E+04 5.951 6.977 42.533 127.374 P123 Position #11 CTMT AUX Grouted 1.93E+08 7.61E+06 3.36E+09 2.31E+06 1.61E+04 1.10E+08 7.10E+05 9.68E+04 6.243 7.319 44.617 133.613 P123 Position #12 CTMT AUX Grouted 1.93E+08 7.60E+06 3.36E+09 2.30E+06 1.61E+04 1.10E+08 7.08E+05 9.66E+04 6.231 7.305 44.532 133.359 P123 Position #13 CTMT AUX Grouted 2.03E+08 7.99E+06 3.53E+09 2.42E+06 1.69E+04 1.15E+08 7.45E+05 1.02E+05 6.555 7.685 46.850 140.300 P123 Position #14 CTMT AUX Grouted 1.81E+08 7.13E+06 3.15E+09 2.16E+06 1.51E+04 1.03E+08 6.64E+05 9.06E+04 5.845 6.853 41.776 125.105 P123 Position #15 CTMT AUX Grouted 1.41E+08 5.54E+06 2.45E+09 1.68E+06 1.17E+04 8.00E+07 5.16E+05 7.04E+04 4.544 5.327 32.475 97.251 P123 Position #16 CTMT AUX Grouted 1.19E+08 4.68E+06 2.07E+09 1.42E+06 9.92E+03 6.76E+07 4.37E+05 5.95E+04 3.841 4.503 27.452 82.211 P123 Position #17 CTMT AUX Grouted 1.11E+08 4.37E+06 1.93E+09 1.32E+06 9.25E+03 6.31E+07 4.07E+05 5.55E+04 3.582 4.200 25.603 76.673 P123 Position #18 CTMT AUX Grouted 1.07E+08 4.21E+06 1.86E+09 1.28E+06 8.93E+03 6.09E+07 3.93E+05 5.36E+04 3.456 4.052 24.700 73.968 P123 Position #19 CTMT AUX Grouted 1.11E+08 4.35E+06 1.92E+09 1.32E+06 9.22E+03 6.29E+07 4.06E+05 5.53E+04 3.570 4.185 25.512 76.399 P123 Position #20 CTMT AUX Grouted 8.98E+07 3.53E+06 1.56E+09 1.07E+06 7.48E+03 5.10E+07 3.29E+05 4.49E+04 2.897 3.396 20.701 61.994 P123 Position #21 CTMT AUX Grouted 6.62E+07 2.61E+06 1.15E+09 7.90E+05 5.52E+03 3.76E+07 2.43E+05 3.31E+04 2.137 2.505 15.271 45.733 P123 Position #22 CTMT AUX Grouted 5.80E+07 2.28E+06 1.01E+09 6.92E+05 4.83E+03 3.29E+07 2.13E+05 2.90E+04 1.870 2.193 13.366 40.028 P123 Position #23 CTMT AUX Grouted 4.22E+07 1.66E+06 7.34E+08 5.04E+05 3.52E+03 2.40E+07 1.55E+05 2.11E+04 1.362 1.597 9.734 29.150 P123 Position #24 CTMT AUX Grouted 2.32E+07 9.14E+05 4.04E+08 2.77E+05 1.94E+03 1.32E+07 8.52E+04 1.16E+04 0.749 0.879 5.356 16.041 P123 Position #25 CTMT AUX Grouted 1.82E+07 7.14E+05 3.16E+08 2.17E+05 1.51E+03 1.03E+07 6.66E+04 9.08E+03 0.586 0.687 4.186 12.536 P123 Position #26 CTMT AUX Grouted 1.51E+07 5.93E+05 2.62E+08 1.80E+05 1.26E+03 8.57E+06 5.53E+04 7.54E+03 0.487 0.571 3.478 10.417 P123 Position #27 CTMT AUX Grouted 1.50E+07 5.89E+05 2.60E+08 1.79E+05 1.25E+03 8.51E+06 5.49E+04 7.49E+03 0.483 0.567 3.455 10.346 P123 Position #28 CTMT AUX Grouted 1.17E+07 4.60E+05 2.03E+08 1.39E+05 9.74E+02 6.64E+06 4.28E+04 5.84E+03 0.377 0.442 2.694 8.068 P123 Position #29 CTMT AUX Grouted 8.87E+06 3.49E+05 1.54E+08 1.06E+05 7.40E+02 5.04E+06 3.25E+04 4.44E+03 0.286 0.336 2.046 6.128 P123 Position #30 CTMT AUX Grouted 7.70E+06 3.03E+05 1.34E+08 9.19E+04 6.42E+02 4.37E+06 2.82E+04 3.85E+03 0.248 0.291 1.776 5.317 P123 Position #31 CTMT AUX Grouted 7.24E+06 2.85E+05 1.26E+08 8.64E+04 6.04E+02 4.12E+06 2.66E+04 3.62E+03 0.234 0.274 1.670 5.002 P123 Position #32 CTMT AUX Grouted 6.98E+06 2.75E+05 1.21E+08 8.33E+04 5.82E+02 3.97E+06 2.56E+04 3.49E+03 0.225 0.264 1.610 4.823 P123 Position #33 CTMT AUX Grouted 7.33E+06 2.89E+05 1.28E+08 8.75E+04 6.11E+02 4.17E+06 2.69E+04 3.67E+03 0.237 0.277 1.691 5.065 P123 Position #34 CTMT AUX Grouted 8.01E+06 3.15E+05 1.39E+08 9.55E+04 6.67E+02 4.55E+06 2.94E+04 4.00E+03 0.258 0.303 1.846 5.529 P123 Position #35 CTMT AUX Grouted 9.98E+06 3.93E+05 1.74E+08 1.19E+05 8.32E+02 5.67E+06 3.66E+04 4.99E+03 0.322 0.378 2.302 6.894 P123 Position #36 CTMT AUX Grouted 8.07E+06 3.18E+05 1.40E+08 9.63E+04 6.73E+02 4.59E+06 2.96E+04 4.04E+03 0.261 0.305 1.862 5.576 P123 Position #37 CTMT AUX Grouted 7.91E+06 3.11E+05 1.38E+08 9.44E+04 6.60E+02 4.50E+06 2.90E+04 3.96E+03 0.255 0.299 1.825 5.465 P123 Position #38 CTMT AUX Grouted 6.59E+06 2.59E+05 1.15E+08 7.86E+04 5.49E+02 3.74E+06 2.42E+04 3.29E+03 0.213 0.249 1.519 4.550 P123 Position #39 CTMT AUX Grouted 6.09E+06 2.40E+05 1.06E+08 7.27E+04 5.08E+02 3.46E+06 2.23E+04 3.05E+03 0.197 0.230 1.404 4.206 P123 Position #40 CTMT AUX Grouted 6.10E+06 2.40E+05 1.06E+08 7.28E+04 5.08E+02 3.46E+06 2.24E+04 3.05E+03 0.197 0.231 1.406 4.211 P123 Position #41 CTMT AUX Grouted 6.30E+06 2.48E+05 1.10E+08 7.52E+04 5.25E+02 3.58E+06 2.31E+04 3.15E+03 0.203 0.238 1.453 4.352 P123 Position #42 CTMT AUX Grouted 6.92E+06 2.72E+05 1.20E+08 8.25E+04 5.77E+02 3.93E+06 2.54E+04 3.46E+03 0.223 0.262 1.595 4.777 P123 Position #43 CTMT AUX Grouted 6.83E+06 2.69E+05 1.19E+08 8.15E+04 5.69E+02 3.88E+06 2.50E+04 3.41E+03 0.220 0.258 1.574 4.714 P123 Position #44 CTMT AUX Grouted 9.49E+06 3.73E+05 1.65E+08 1.13E+05 7.91E+02 5.39E+06 3.48E+04 4.74E+03 0.306 0.359 2.188 6.551 P123 Position #45 CTMT AUX Grouted 6.67E+06 2.62E+05 1.16E+08 7.96E+04 5.56E+02 3.79E+06 2.45E+04 3.34E+03 0.215 0.252 1.538 4.607 P123 Position #46 CTMT AUX Grouted 5.93E+06 2.33E+05 1.03E+08 7.08E+04 4.95E+02 3.37E+06 2.18E+04 2.97E+03 0.191 0.224 1.368 4.098 MEASUREMENT ID BETWEEN END STATE
~
=ZIONSOLUTIONSuc-An Er,e,,gyS~ Company
FSS RELEASE RECORD, REV 1 PENETRATIONS SURVEY UNITS 01112, 02112 and 05120
[66]
Unit 1 Containment Penetration Measurements (continued)
H-3 (1)
Co-60 (2)
Ni-63 (1)
Sr-90 (1)
Cs-134 (2)
Cs-137 (2)
Eu-152 (2)
Eu-154 (2)
OpSOFPN OpSOFPN OpSOFB OpSOFB (pCi/m2)
(pCi/m2)
(pCi/m2)
(pCi/m2)
(pCi/m2)
(pCi/m2)
(pCi/m2)
(pCi/m2)
CTMTPN Limiting DCGL CTMT DCGL Limiting DCGL P123 Position #47 CTMT AUX Grouted 6.15E+06 2.42E+05 1.07E+08 7.34E+04 5.12E+02 3.49E+06 2.25E+04 3.07E+03 0.198 0.233 1.418 4.246 P123 Position #48 CTMT AUX Grouted 7.26E+06 2.85E+05 1.26E+08 8.66E+04 6.05E+02 4.12E+06 2.66E+04 3.63E+03 0.234 0.274 1.673 5.011 P123 Position #49 CTMT AUX Grouted 6.83E+06 2.69E+05 1.19E+08 8.15E+04 5.69E+02 3.88E+06 2.51E+04 3.42E+03 0.220 0.258 1.576 4.719 P123 Position #50 CTMT AUX Grouted 6.54E+06 2.57E+05 1.14E+08 7.81E+04 5.45E+02 3.72E+06 2.40E+04 3.27E+03 0.211 0.247 1.509 4.517 P124 Position #1 CTMT AUX Grouted 8.20E+07 3.23E+06 1.43E+09 9.79E+05 6.84E+03 4.66E+07 3.01E+05 4.10E+04 2.647 3.103 18.915 56.645 P124 Position #2 CTMT AUX Grouted 6.80E+07 2.68E+06 1.18E+09 8.11E+05 5.67E+03 3.86E+07 2.49E+05 3.40E+04 2.194 2.573 15.683 46.966 P124 Position #3 CTMT AUX Grouted 7.10E+07 2.80E+06 1.24E+09 8.48E+05 5.92E+03 4.04E+07 2.61E+05 3.55E+04 2.293 2.688 16.385 49.067 P124 Position #4 CTMT AUX Grouted 7.18E+07 2.83E+06 1.25E+09 8.57E+05 5.99E+03 4.08E+07 2.63E+05 3.59E+04 2.318 2.717 16.564 49.603 P124 Position #5 CTMT AUX Grouted 7.08E+07 2.79E+06 1.23E+09 8.45E+05 5.90E+03 4.02E+07 2.60E+05 3.54E+04 2.286 2.680 16.335 48.917 P124 Position #6 CTMT AUX Grouted 6.72E+07 2.64E+06 1.17E+09 8.02E+05 5.60E+03 3.82E+07 2.46E+05 3.36E+04 2.169 2.543 15.500 46.417 P124 Position #7 CTMT AUX Grouted 5.96E+07 2.35E+06 1.04E+09 7.12E+05 4.97E+03 3.39E+07 2.19E+05 2.98E+04 1.924 2.256 13.752 41.184 P124 Position #8 CTMT AUX Grouted 5.76E+07 2.27E+06 1.00E+09 6.87E+05 4.80E+03 3.27E+07 2.11E+05 2.88E+04 1.859 2.180 13.287 39.789 P124 Position #9 CTMT AUX Grouted 5.79E+07 2.28E+06 1.01E+09 6.91E+05 4.83E+03 3.29E+07 2.12E+05 2.90E+04 1.868 2.190 13.351 39.981 P124 Position #10 CTMT AUX Grouted 5.90E+07 2.32E+06 1.03E+09 7.04E+05 4.92E+03 3.35E+07 2.16E+05 2.95E+04 1.904 2.232 13.606 40.744 P124 Position #11 CTMT AUX Grouted 6.11E+07 2.40E+06 1.06E+09 7.29E+05 5.09E+03 3.47E+07 2.24E+05 3.05E+04 1.971 2.311 14.086 42.182 P124 Position #12 CTMT AUX Grouted 6.22E+07 2.45E+06 1.08E+09 7.42E+05 5.18E+03 3.53E+07 2.28E+05 3.11E+04 2.007 2.352 14.340 42.945 P124 Position #13 CTMT AUX Grouted 6.30E+07 2.48E+06 1.09E+09 7.51E+05 5.25E+03 3.58E+07 2.31E+05 3.15E+04 2.031 2.381 14.517 43.474 P124 Position #14 CTMT AUX Grouted 6.56E+07 2.58E+06 1.14E+09 7.82E+05 5.47E+03 3.73E+07 2.40E+05 3.28E+04 2.116 2.480 15.121 45.282 P124 Position #15 CTMT AUX Grouted 6.30E+07 2.48E+06 1.10E+09 7.52E+05 5.25E+03 3.58E+07 2.31E+05 3.15E+04 2.034 2.384 14.535 43.528 P124 Position #16 CTMT AUX Grouted 5.04E+07 1.98E+06 8.76E+08 6.01E+05 4.20E+03 2.86E+07 1.85E+05 2.52E+04 1.626 1.907 11.624 34.811 P124 Position #17 CTMT AUX Grouted 4.42E+07 1.74E+06 7.69E+08 5.28E+05 3.69E+03 2.51E+07 1.62E+05 2.21E+04 1.427 1.673 10.200 30.546 P124 Position #18 CTMT AUX Grouted 4.10E+07 1.61E+06 7.13E+08 4.89E+05 3.42E+03 2.33E+07 1.50E+05 2.05E+04 1.323 1.551 9.454 28.312 P124 Position #19 CTMT AUX Grouted 3.55E+07 1.40E+06 6.17E+08 4.24E+05 2.96E+03 2.02E+07 1.30E+05 1.78E+04 1.146 1.343 8.189 24.523 P124 Position #20 CTMT AUX Grouted 2.94E+07 1.16E+06 5.11E+08 3.50E+05 2.45E+03 1.67E+07 1.08E+05 1.47E+04 0.947 1.111 6.771 20.276 P124 Position #21 CTMT AUX Grouted 2.45E+07 9.65E+05 4.27E+08 2.93E+05 2.05E+03 1.39E+07 9.00E+04 1.23E+04 0.792 0.928 5.658 16.945 P124 Position #22 CTMT AUX Grouted 1.98E+07 7.77E+05 3.43E+08 2.36E+05 1.65E+03 1.12E+07 7.24E+04 9.88E+03 0.637 0.747 4.555 13.639 P124 Position #23 CTMT AUX Grouted 1.41E+07 5.53E+05 2.45E+08 1.68E+05 1.17E+03 7.99E+06 5.16E+04 7.03E+03 0.454 0.532 3.243 9.712 P124 Position #24 CTMT AUX Grouted 1.03E+07 4.06E+05 1.79E+08 1.23E+05 8.60E+02 5.86E+06 3.78E+04 5.16E+03 0.333 0.390 2.380 7.128 P124 Position #25 CTMT AUX Grouted 8.12E+06 3.19E+05 1.41E+08 9.68E+04 6.76E+02 4.61E+06 2.98E+04 4.06E+03 0.262 0.307 1.871 5.604 P124 Position #26 CTMT AUX Grouted 7.94E+06 3.12E+05 1.38E+08 9.47E+04 6.61E+02 4.51E+06 2.91E+04 3.97E+03 0.256 0.300 1.830 5.480 P124 Position #27 CTMT AUX Grouted 6.81E+06 2.68E+05 1.18E+08 8.13E+04 5.68E+02 3.87E+06 2.50E+04 3.41E+03 0.220 0.258 1.571 4.705 P124 Position #28 CTMT AUX Grouted 6.35E+06 2.50E+05 1.10E+08 7.58E+04 5.29E+02 3.61E+06 2.33E+04 3.18E+03 0.205 0.240 1.465 4.387 P124 Position #29 CTMT AUX Grouted 5.84E+06 2.30E+05 1.02E+08 6.97E+04 4.87E+02 3.32E+06 2.14E+04 2.92E+03 0.189 0.221 1.347 4.034 P124 Position #30 CTMT AUX Grouted 5.60E+06 2.20E+05 9.73E+07 6.68E+04 4.67E+02 3.18E+06 2.05E+04 2.80E+03 0.181 0.212 1.291 3.866 P124 Position #31 CTMT AUX Grouted 5.62E+06 2.21E+05 9.77E+07 6.70E+04 4.68E+02 3.19E+06 2.06E+04 2.81E+03 0.181 0.212 1.295 3.879 P124 Position #32 CTMT AUX Grouted 5.32E+06 2.09E+05 9.25E+07 6.35E+04 4.43E+02 3.02E+06 1.95E+04 2.66E+03 0.172 0.201 1.227 3.674 P124 Position #33 CTMT AUX Grouted 5.28E+06 2.08E+05 9.17E+07 6.30E+04 4.40E+02 3.00E+06 1.93E+04 2.64E+03 0.170 0.200 1.217 3.644 P124 Position #34 CTMT AUX Grouted 5.27E+06 2.07E+05 9.16E+07 6.28E+04 4.39E+02 2.99E+06 1.93E+04 2.63E+03 0.170 0.199 1.214 3.637 P124 Position #35 CTMT AUX Grouted 5.86E+06 2.31E+05 1.02E+08 6.99E+04 4.88E+02 3.33E+06 2.15E+04 2.93E+03 0.189 0.222 1.352 4.047 P124 Position #36 CTMT AUX Grouted 5.28E+06 2.08E+05 9.18E+07 6.30E+04 4.40E+02 3.00E+06 1.94E+04 2.64E+03 0.170 0.200 1.218 3.647 P124 Position #37 CTMT AUX Grouted 4.97E+06 1.96E+05 8.64E+07 5.93E+04 4.14E+02 2.82E+06 1.82E+04 2.49E+03 0.160 0.188 1.146 3.432 P124 Position #38 CTMT AUX Grouted 4.83E+06 1.90E+05 8.39E+07 5.76E+04 4.02E+02 2.74E+06 1.77E+04 2.41E+03 0.156 0.183 1.113 3.334 P124 Position #39 CTMT AUX Grouted 4.85E+06 1.91E+05 8.43E+07 5.78E+04 4.04E+02 2.75E+06 1.78E+04 2.42E+03 0.156 0.183 1.118 3.347 P124 Position #40 CTMT AUX Grouted 4.96E+06 1.95E+05 8.63E+07 5.92E+04 4.14E+02 2.82E+06 1.82E+04 2.48E+03 0.160 0.188 1.145 3.429 P124 Position #41 CTMT AUX Grouted 4.76E+06 1.87E+05 8.28E+07 5.68E+04 3.97E+02 2.71E+06 1.75E+04 2.38E+03 0.154 0.180 1.099 3.290 P124 Position #42 CTMT AUX Grouted 4.80E+06 1.89E+05 8.34E+07 5.73E+04 4.00E+02 2.73E+06 1.76E+04 2.40E+03 0.155 0.182 1.107 3.314 P124 Position #43 CTMT AUX Grouted 5.06E+06 1.99E+05 8.80E+07 6.04E+04 4.22E+02 2.87E+06 1.86E+04 2.53E+03 0.163 0.191 1.167 3.494 P124 Position #44 CTMT AUX Grouted 5.09E+06 2.00E+05 8.85E+07 6.07E+04 4.24E+02 2.89E+06 1.87E+04 2.54E+03 0.164 0.192 1.173 3.514 P124 Position #45 CTMT AUX Grouted 4.80E+06 1.89E+05 8.35E+07 5.73E+04 4.00E+02 2.73E+06 1.76E+04 2.40E+03 0.155 0.182 1.107 3.316 P124 Position #46 CTMT AUX Grouted 4.77E+06 1.87E+05 8.29E+07 5.69E+04 3.97E+02 2.71E+06 1.75E+04 2.38E+03 0.154 0.180 1.099 3.291 P124 Position #47 CTMT AUX Grouted 4.59E+06 1.81E+05 7.98E+07 5.48E+04 3.83E+02 2.61E+06 1.68E+04 2.30E+03 0.148 0.174 1.059 3.171 MEASUREMENT ID BETWEEN END STATE
~
=ZIONSOLUTIONSuc-An Er,e,,gyS~ Company
FSS RELEASE RECORD, REV 1 PENETRATIONS SURVEY UNITS 01112, 02112 and 05120
[67]
Unit 1 Containment Penetration Measurements (continued)
H-3 (1)
Co-60 (2)
Ni-63 (1)
Sr-90 (1)
Cs-134 (2)
Cs-137 (2)
Eu-152 (2)
Eu-154 (2)
OpSOFPN OpSOFPN OpSOFB OpSOFB (pCi/m2)
(pCi/m2)
(pCi/m2)
(pCi/m2)
(pCi/m2)
(pCi/m2)
(pCi/m2)
(pCi/m2)
CTMTPN Limiting DCGL CTMT DCGL Limiting DCGL P124 Position #48 CTMT AUX Grouted 4.46E+06 1.75E+05 7.75E+07 5.32E+04 3.71E+02 2.53E+06 1.63E+04 2.23E+03 0.144 0.169 1.028 3.077 P124 Position #49 CTMT AUX Grouted 4.59E+06 1.80E+05 7.98E+07 5.47E+04 3.82E+02 2.61E+06 1.68E+04 2.29E+03 0.148 0.174 1.058 3.169 P124 Position #50 CTMT AUX Grouted 4.52E+06 1.78E+05 7.85E+07 5.39E+04 3.76E+02 2.57E+06 1.66E+04 2.26E+03 0.146 0.171 1.041 3.118 P037 Position #1 CTMT AUX Grouted 1.56E+07 6.15E+05 2.72E+08 1.86E+05 1.30E+03 8.88E+06 5.73E+04 7.82E+03 0.504 0.591 3.604 10.793 P037 Position #2 CTMT AUX Grouted 7.23E+06 2.85E+05 1.26E+08 8.63E+04 6.03E+02 4.11E+06 2.65E+04 3.62E+03 0.233 0.274 1.668 4.995 P037 Position #3 CTMT AUX Grouted 7.69E+06 3.02E+05 1.34E+08 9.17E+04 6.41E+02 4.37E+06 2.82E+04 3.84E+03 0.248 0.291 1.773 5.309 P037 Position #4 CTMT AUX Grouted 4.50E+06 1.77E+05 7.82E+07 5.36E+04 3.75E+02 2.55E+06 1.65E+04 2.25E+03 0.145 0.170 1.037 3.105 P037 Position #5 CTMT AUX Grouted 4.17E+06 1.64E+05 7.25E+07 4.97E+04 3.47E+02 2.37E+06 1.53E+04 2.08E+03 0.134 0.158 0.961 2.878 P037 Position #6 CTMT AUX Grouted 4.29E+06 1.69E+05 7.47E+07 5.12E+04 3.58E+02 2.44E+06 1.57E+04 2.15E+03 0.139 0.162 0.990 2.965 P037 Position #7 CTMT AUX Grouted 4.05E+06 1.59E+05 7.04E+07 4.83E+04 3.38E+02 2.30E+06 1.49E+04 2.03E+03 0.131 0.153 0.934 2.798 P037 Position #8 CTMT AUX Grouted 4.04E+06 1.59E+05 7.03E+07 4.82E+04 3.37E+02 2.30E+06 1.48E+04 2.02E+03 0.130 0.153 0.932 2.791 P037 Position #9 CTMT AUX Grouted 3.90E+06 1.54E+05 6.79E+07 4.66E+04 3.25E+02 2.22E+06 1.43E+04 1.95E+03 0.126 0.148 0.900 2.696 P037 Position #10 CTMT AUX Grouted 3.96E+06 1.56E+05 6.89E+07 4.73E+04 3.30E+02 2.25E+06 1.45E+04 1.98E+03 0.128 0.150 0.913 2.735 P037 Position #11 CTMT AUX Grouted 3.94E+06 1.55E+05 6.86E+07 4.71E+04 3.29E+02 2.24E+06 1.45E+04 1.97E+03 0.127 0.149 0.910 2.724 P037 Position #12 CTMT AUX Grouted 3.95E+06 1.56E+05 6.88E+07 4.72E+04 3.30E+02 2.25E+06 1.45E+04 1.98E+03 0.128 0.150 0.912 2.731 P037 Position #13 CTMT AUX Grouted 4.04E+06 1.59E+05 7.02E+07 4.82E+04 3.36E+02 2.29E+06 1.48E+04 2.02E+03 0.130 0.153 0.931 2.787 P037 Position #14 CTMT AUX Grouted 3.96E+06 1.56E+05 6.89E+07 4.73E+04 3.30E+02 2.25E+06 1.45E+04 1.98E+03 0.128 0.150 0.913 2.735 P037 Position #15 CTMT AUX Grouted 3.82E+06 1.50E+05 6.65E+07 4.56E+04 3.19E+02 2.17E+06 1.40E+04 1.91E+03 0.123 0.145 0.882 2.641 P037 Position #16 CTMT AUX Grouted 3.87E+06 1.52E+05 6.74E+07 4.62E+04 3.23E+02 2.20E+06 1.42E+04 1.94E+03 0.125 0.147 0.893 2.675 P037 Position #17 CTMT AUX Grouted 3.86E+06 1.52E+05 6.72E+07 4.61E+04 3.22E+02 2.20E+06 1.42E+04 1.93E+03 0.125 0.146 0.891 2.668 P037 Position #18 CTMT AUX Grouted 3.72E+06 1.46E+05 6.46E+07 4.44E+04 3.10E+02 2.11E+06 1.36E+04 1.86E+03 0.120 0.141 0.857 2.567 P037 Position #19 CTMT AUX Grouted 3.90E+06 1.53E+05 6.78E+07 4.65E+04 3.25E+02 2.22E+06 1.43E+04 1.95E+03 0.126 0.148 0.899 2.693 P037 Position #20 CTMT AUX Grouted 3.88E+06 1.53E+05 6.75E+07 4.63E+04 3.23E+02 2.20E+06 1.42E+04 1.94E+03 0.125 0.147 0.895 2.679 P037 Position #21 CTMT AUX Grouted 3.79E+06 1.49E+05 6.59E+07 4.52E+04 3.16E+02 2.15E+06 1.39E+04 1.89E+03 0.122 0.143 0.874 2.616 P037 Position #22 CTMT AUX Grouted 3.79E+06 1.49E+05 6.59E+07 4.52E+04 3.16E+02 2.15E+06 1.39E+04 1.89E+03 0.122 0.143 0.874 2.616 P037 Position #23 CTMT AUX Grouted 3.69E+06 1.45E+05 6.41E+07 4.40E+04 3.07E+02 2.09E+06 1.35E+04 1.84E+03 0.119 0.139 0.850 2.546 P037 Position #24 CTMT AUX Grouted 3.49E+06 1.37E+05 6.07E+07 4.16E+04 2.91E+02 1.98E+06 1.28E+04 1.75E+03 0.113 0.132 0.805 2.410 P037 Position #25 CTMT AUX Grouted 3.40E+06 1.34E+05 5.91E+07 4.06E+04 2.83E+02 1.93E+06 1.25E+04 1.70E+03 0.110 0.129 0.784 2.347 P037 Position #26 CTMT AUX Grouted 3.49E+06 1.37E+05 6.08E+07 4.17E+04 2.91E+02 1.99E+06 1.28E+04 1.75E+03 0.113 0.132 0.806 2.413 P037 Position #27 CTMT AUX Grouted 3.40E+06 1.34E+05 5.91E+07 4.06E+04 2.83E+02 1.93E+06 1.25E+04 1.70E+03 0.110 0.129 0.784 2.347 P037 Position #28 CTMT AUX Grouted 3.46E+06 1.36E+05 6.02E+07 4.13E+04 2.89E+02 1.97E+06 1.27E+04 1.73E+03 0.112 0.131 0.799 2.393 P037 Position #29 CTMT AUX Grouted 3.48E+06 1.37E+05 6.05E+07 4.15E+04 2.90E+02 1.98E+06 1.28E+04 1.74E+03 0.112 0.132 0.802 2.403 P037 Position #30 CTMT AUX Grouted 3.46E+06 1.36E+05 6.02E+07 4.13E+04 2.89E+02 1.97E+06 1.27E+04 1.73E+03 0.112 0.131 0.799 2.393 P037 Position #31 CTMT AUX Grouted 3.46E+06 1.36E+05 6.02E+07 4.13E+04 2.89E+02 1.97E+06 1.27E+04 1.73E+03 0.112 0.131 0.799 2.393 P037 Position #32 CTMT AUX Grouted 3.61E+06 1.42E+05 6.27E+07 4.30E+04 3.01E+02 2.05E+06 1.32E+04 1.80E+03 0.116 0.136 0.832 2.490 P037 Position #33 CTMT AUX Grouted 3.58E+06 1.41E+05 6.23E+07 4.27E+04 2.98E+02 2.03E+06 1.31E+04 1.79E+03 0.116 0.135 0.826 2.473 P037 Position #34 CTMT AUX Grouted 3.57E+06 1.40E+05 6.20E+07 4.25E+04 2.97E+02 2.03E+06 1.31E+04 1.78E+03 0.115 0.135 0.822 2.462 P037 Position #35 CTMT AUX Grouted 3.51E+06 1.38E+05 6.11E+07 4.19E+04 2.93E+02 2.00E+06 1.29E+04 1.76E+03 0.113 0.133 0.811 2.427 P037 Position #36 CTMT AUX Grouted 3.58E+06 1.41E+05 6.22E+07 4.27E+04 2.98E+02 2.03E+06 1.31E+04 1.79E+03 0.115 0.135 0.825 2.469 P037 Position #37 CTMT AUX Grouted 3.63E+06 1.43E+05 6.31E+07 4.33E+04 3.02E+02 2.06E+06 1.33E+04 1.81E+03 0.117 0.137 0.836 2.504 P037 Position #38 CTMT AUX Grouted 3.50E+06 1.38E+05 6.09E+07 4.18E+04 2.92E+02 1.99E+06 1.29E+04 1.75E+03 0.113 0.133 0.808 2.420 P037 Position #39 CTMT AUX Grouted 3.51E+06 1.38E+05 6.10E+07 4.19E+04 2.93E+02 1.99E+06 1.29E+04 1.76E+03 0.113 0.133 0.809 2.424 P037 Position #40 CTMT AUX Grouted 3.52E+06 1.38E+05 6.12E+07 4.20E+04 2.93E+02 2.00E+06 1.29E+04 1.76E+03 0.114 0.133 0.812 2.431 P037 Position #41 CTMT AUX Grouted 3.59E+06 1.41E+05 6.24E+07 4.28E+04 2.99E+02 2.04E+06 1.32E+04 1.79E+03 0.116 0.136 0.827 2.476 P037 Position #42 CTMT AUX Grouted 3.66E+06 1.44E+05 6.36E+07 4.36E+04 3.05E+02 2.08E+06 1.34E+04 1.83E+03 0.118 0.138 0.843 2.525 P037 Position #43 CTMT AUX Grouted 3.69E+06 1.45E+05 6.41E+07 4.40E+04 3.07E+02 2.09E+06 1.35E+04 1.84E+03 0.119 0.139 0.850 2.546 P037 Position #44 CTMT AUX Grouted 3.75E+06 1.48E+05 6.53E+07 4.48E+04 3.13E+02 2.13E+06 1.38E+04 1.88E+03 0.121 0.142 0.865 2.592 P037 Position #45 CTMT AUX Grouted 3.73E+06 1.47E+05 6.49E+07 4.45E+04 3.11E+02 2.12E+06 1.37E+04 1.87E+03 0.120 0.141 0.861 2.578 P037 Position #46 CTMT AUX Grouted 3.84E+06 1.51E+05 6.68E+07 4.59E+04 3.20E+02 2.18E+06 1.41E+04 1.92E+03 0.124 0.145 0.886 2.654 P037 Position #47 CTMT AUX Grouted 3.82E+06 1.50E+05 6.65E+07 4.56E+04 3.19E+02 2.17E+06 1.40E+04 1.91E+03 0.123 0.145 0.882 2.641 P037 Position #48 CTMT AUX Grouted 3.97E+06 1.56E+05 6.89E+07 4.73E+04 3.30E+02 2.25E+06 1.45E+04 1.98E+03 0.128 0.150 0.914 2.738 MEASUREMENT ID BETWEEN END STATE
~
=ZIONSOLUTIONSuc-An Er,e,,gyS~ Company
FSS RELEASE RECORD, REV 1 PENETRATIONS SURVEY UNITS 01112, 02112 and 05120
[68]
Unit 1 Containment Penetration Measurements (continued)
H-3 (1)
Co-60 (2)
Ni-63 (1)
Sr-90 (1)
Cs-134 (2)
Cs-137 (2)
Eu-152 (2)
Eu-154 (2)
OpSOFPN OpSOFPN OpSOFB OpSOFB (pCi/m2)
(pCi/m2)
(pCi/m2)
(pCi/m2)
(pCi/m2)
(pCi/m2)
(pCi/m2)
(pCi/m2)
CTMTPN Limiting DCGL CTMT DCGL Limiting DCGL P037 Position #49 CTMT AUX Grouted 4.04E+06 1.59E+05 7.03E+07 4.82E+04 3.37E+02 2.30E+06 1.48E+04 2.02E+03 0.130 0.153 0.932 2.791 P037 Position #50 CTMT AUX Grouted 4.07E+06 1.60E+05 7.08E+07 4.86E+04 3.39E+02 2.31E+06 1.49E+04 2.04E+03 0.131 0.154 0.939 2.812 P036 Position #1 CTMT AUX Grouted 2.37E+07 9.33E+05 4.12E+08 2.83E+05 1.98E+03 1.35E+07 8.70E+04 1.19E+04 0.765 0.897 5.470 16.381 P036 Position #2 CTMT AUX Grouted 8.09E+06 3.18E+05 1.41E+08 9.66E+04 6.74E+02 4.60E+06 2.97E+04 4.05E+03 0.261 0.306 1.866 5.588 P036 Position #3 CTMT AUX Grouted 4.74E+06 1.87E+05 8.25E+07 5.66E+04 3.95E+02 2.70E+06 1.74E+04 2.37E+03 0.153 0.179 1.094 3.276 P036 Position #4 CTMT AUX Grouted 4.36E+06 1.72E+05 7.58E+07 5.20E+04 3.63E+02 2.48E+06 1.60E+04 2.18E+03 0.141 0.165 1.005 3.011 P036 Position #5 CTMT AUX Grouted 4.30E+06 1.69E+05 7.48E+07 5.14E+04 3.59E+02 2.45E+06 1.58E+04 2.15E+03 0.139 0.163 0.993 2.972 P036 Position #6 CTMT AUX Grouted 4.17E+06 1.64E+05 7.26E+07 4.98E+04 3.48E+02 2.37E+06 1.53E+04 2.09E+03 0.135 0.158 0.962 2.881 P036 Position #7 CTMT AUX Grouted 3.93E+06 1.55E+05 6.83E+07 4.69E+04 3.28E+02 2.23E+06 1.44E+04 1.97E+03 0.127 0.149 0.906 2.714 P036 Position #8 CTMT AUX Grouted 3.94E+06 1.55E+05 6.86E+07 4.71E+04 3.29E+02 2.24E+06 1.45E+04 1.97E+03 0.127 0.149 0.910 2.724 P036 Position #9 CTMT AUX Grouted 3.83E+06 1.51E+05 6.67E+07 4.57E+04 3.20E+02 2.18E+06 1.41E+04 1.92E+03 0.124 0.145 0.884 2.647 P036 Position #10 CTMT AUX Grouted 3.86E+06 1.52E+05 6.72E+07 4.61E+04 3.22E+02 2.20E+06 1.42E+04 1.93E+03 0.125 0.146 0.891 2.668 P036 Position #11 CTMT AUX Grouted 3.84E+06 1.51E+05 6.68E+07 4.59E+04 3.20E+02 2.18E+06 1.41E+04 1.92E+03 0.124 0.145 0.886 2.654 P036 Position #12 CTMT AUX Grouted 3.79E+06 1.49E+05 6.60E+07 4.53E+04 3.16E+02 2.16E+06 1.39E+04 1.90E+03 0.122 0.143 0.875 2.620 P036 Position #13 CTMT AUX Grouted 3.72E+06 1.46E+05 6.46E+07 4.44E+04 3.10E+02 2.11E+06 1.36E+04 1.86E+03 0.120 0.141 0.857 2.567 P036 Position #14 CTMT AUX Grouted 3.74E+06 1.47E+05 6.51E+07 4.47E+04 3.12E+02 2.13E+06 1.37E+04 1.87E+03 0.121 0.142 0.863 2.585 P036 Position #15 CTMT AUX Grouted 3.82E+06 1.50E+05 6.65E+07 4.56E+04 3.19E+02 2.17E+06 1.40E+04 1.91E+03 0.123 0.145 0.882 2.641 P036 Position #16 CTMT AUX Grouted 3.70E+06 1.45E+05 6.43E+07 4.41E+04 3.08E+02 2.10E+06 1.36E+04 1.85E+03 0.119 0.140 0.853 2.553 P036 Position #17 CTMT AUX Grouted 3.77E+06 1.48E+05 6.55E+07 4.50E+04 3.14E+02 2.14E+06 1.38E+04 1.88E+03 0.122 0.143 0.869 2.602 P036 Position #18 CTMT AUX Grouted 3.71E+06 1.46E+05 6.45E+07 4.43E+04 3.09E+02 2.11E+06 1.36E+04 1.86E+03 0.120 0.140 0.856 2.564 P036 Position #19 CTMT AUX Grouted 3.66E+06 1.44E+05 6.37E+07 4.37E+04 3.05E+02 2.08E+06 1.34E+04 1.83E+03 0.118 0.139 0.844 2.529 P036 Position #20 CTMT AUX Grouted 3.61E+06 1.42E+05 6.27E+07 4.30E+04 3.01E+02 2.05E+06 1.32E+04 1.80E+03 0.116 0.136 0.832 2.490 P036 Position #21 CTMT AUX Grouted 3.35E+06 1.32E+05 5.83E+07 4.00E+04 2.79E+02 1.91E+06 1.23E+04 1.68E+03 0.108 0.127 0.773 2.316 P036 Position #22 CTMT AUX Grouted 3.38E+06 1.33E+05 5.87E+07 4.03E+04 2.82E+02 1.92E+06 1.24E+04 1.69E+03 0.109 0.128 0.779 2.333 P036 Position #23 CTMT AUX Grouted 3.35E+06 1.32E+05 5.83E+07 4.00E+04 2.79E+02 1.91E+06 1.23E+04 1.68E+03 0.108 0.127 0.773 2.316 P036 Position #24 CTMT AUX Grouted 3.19E+06 1.26E+05 5.55E+07 3.81E+04 2.66E+02 1.81E+06 1.17E+04 1.60E+03 0.103 0.121 0.736 2.204 P036 Position #25 CTMT AUX Grouted 3.26E+06 1.28E+05 5.66E+07 3.89E+04 2.71E+02 1.85E+06 1.19E+04 1.63E+03 0.105 0.123 0.751 2.249 P036 Position #26 CTMT AUX Grouted 3.24E+06 1.27E+05 5.63E+07 3.86E+04 2.70E+02 1.84E+06 1.19E+04 1.62E+03 0.104 0.122 0.746 2.235 P036 Position #27 CTMT AUX Grouted 3.33E+06 1.31E+05 5.80E+07 3.98E+04 2.78E+02 1.89E+06 1.22E+04 1.67E+03 0.108 0.126 0.769 2.302 P036 Position #28 CTMT AUX Grouted 3.40E+06 1.34E+05 5.92E+07 4.06E+04 2.84E+02 1.93E+06 1.25E+04 1.70E+03 0.110 0.129 0.785 2.351 P036 Position #29 CTMT AUX Grouted 3.34E+06 1.31E+05 5.80E+07 3.98E+04 2.78E+02 1.90E+06 1.22E+04 1.67E+03 0.108 0.126 0.770 2.305 P036 Position #30 CTMT AUX Grouted 3.40E+06 1.34E+05 5.92E+07 4.06E+04 2.84E+02 1.93E+06 1.25E+04 1.70E+03 0.110 0.129 0.785 2.351 P036 Position #31 CTMT AUX Grouted 3.38E+06 1.33E+05 5.88E+07 4.04E+04 2.82E+02 1.92E+06 1.24E+04 1.69E+03 0.109 0.128 0.780 2.337 P036 Position #32 CTMT AUX Grouted 3.46E+06 1.36E+05 6.02E+07 4.13E+04 2.89E+02 1.97E+06 1.27E+04 1.73E+03 0.112 0.131 0.799 2.393 P036 Position #33 CTMT AUX Grouted 3.48E+06 1.37E+05 6.06E+07 4.16E+04 2.90E+02 1.98E+06 1.28E+04 1.74E+03 0.112 0.132 0.804 2.406 P036 Position #34 CTMT AUX Grouted 3.44E+06 1.35E+05 5.98E+07 4.10E+04 2.87E+02 1.95E+06 1.26E+04 1.72E+03 0.111 0.130 0.793 2.375 P036 Position #35 CTMT AUX Grouted 3.49E+06 1.37E+05 6.08E+07 4.17E+04 2.91E+02 1.99E+06 1.28E+04 1.75E+03 0.113 0.132 0.806 2.413 P036 Position #36 CTMT AUX Grouted 3.51E+06 1.38E+05 6.10E+07 4.19E+04 2.93E+02 1.99E+06 1.29E+04 1.76E+03 0.113 0.133 0.809 2.424 P036 Position #37 CTMT AUX Grouted 3.47E+06 1.37E+05 6.04E+07 4.15E+04 2.90E+02 1.97E+06 1.27E+04 1.74E+03 0.112 0.131 0.801 2.400 P036 Position #38 CTMT AUX Grouted 3.45E+06 1.36E+05 6.01E+07 4.12E+04 2.88E+02 1.96E+06 1.27E+04 1.73E+03 0.111 0.131 0.797 2.386 P036 Position #39 CTMT AUX Grouted 3.39E+06 1.34E+05 5.90E+07 4.05E+04 2.83E+02 1.93E+06 1.24E+04 1.70E+03 0.110 0.128 0.783 2.344 P036 Position #40 CTMT AUX Grouted 3.45E+06 1.36E+05 6.00E+07 4.12E+04 2.87E+02 1.96E+06 1.26E+04 1.72E+03 0.111 0.130 0.795 2.382 P036 Position #41 CTMT AUX Grouted 3.58E+06 1.41E+05 6.22E+07 4.27E+04 2.98E+02 2.03E+06 1.31E+04 1.79E+03 0.115 0.135 0.825 2.469 P036 Position #42 CTMT AUX Grouted 3.50E+06 1.38E+05 6.09E+07 4.18E+04 2.92E+02 1.99E+06 1.29E+04 1.75E+03 0.113 0.133 0.808 2.420 P036 Position #43 CTMT AUX Grouted 3.52E+06 1.38E+05 6.12E+07 4.20E+04 2.93E+02 2.00E+06 1.29E+04 1.76E+03 0.114 0.133 0.812 2.431 P036 Position #44 CTMT AUX Grouted 3.68E+06 1.45E+05 6.40E+07 4.39E+04 3.07E+02 2.09E+06 1.35E+04 1.84E+03 0.119 0.139 0.849 2.543 P036 Position #45 CTMT AUX Grouted 3.65E+06 1.44E+05 6.35E+07 4.36E+04 3.04E+02 2.07E+06 1.34E+04 1.83E+03 0.118 0.138 0.842 2.522 P036 Position #46 CTMT AUX Grouted 3.92E+06 1.54E+05 6.82E+07 4.68E+04 3.27E+02 2.23E+06 1.44E+04 1.96E+03 0.126 0.148 0.904 2.707 P036 Position #47 CTMT AUX Grouted 4.17E+06 1.64E+05 7.25E+07 4.97E+04 3.47E+02 2.37E+06 1.53E+04 2.08E+03 0.134 0.158 0.961 2.878 P036 Position #48 CTMT AUX Grouted 4.70E+06 1.85E+05 8.17E+07 5.61E+04 3.92E+02 2.67E+06 1.72E+04 2.35E+03 0.152 0.178 1.084 3.245 P036 Position #49 CTMT AUX Grouted 4.20E+06 1.65E+05 7.31E+07 5.01E+04 3.50E+02 2.39E+06 1.54E+04 2.10E+03 0.136 0.159 0.969 2.902 MEASUREMENT ID BETWEEN END STATE
~
=ZIONSOLUTIONSuc-An Er,e,,gyS~ Company
FSS RELEASE RECORD, REV 1 PENETRATIONS SURVEY UNITS 01112, 02112 and 05120
[69]
Unit 1 Containment Penetration Measurements (continued)
H-3 (1)
Co-60 (2)
Ni-63 (1)
Sr-90 (1)
Cs-134 (2)
Cs-137 (2)
Eu-152 (2)
Eu-154 (2)
OpSOFPN OpSOFPN OpSOFB OpSOFB (pCi/m2)
(pCi/m2)
(pCi/m2)
(pCi/m2)
(pCi/m2)
(pCi/m2)
(pCi/m2)
(pCi/m2)
CTMTPN Limiting DCGL CTMT DCGL Limiting DCGL P036 Position #50 CTMT AUX Grouted 3.76E+06 1.48E+05 6.54E+07 4.49E+04 3.14E+02 2.14E+06 1.38E+04 1.88E+03 0.121 0.142 0.868 2.599 P035 Position #1 CTMT AUX Grouted 1.79E+07 7.04E+05 3.11E+08 2.14E+05 1.49E+03 1.02E+07 6.57E+04 8.95E+03 0.578 0.677 4.129 12.364 P035 Position #2 CTMT AUX Grouted 6.47E+06 2.55E+05 1.13E+08 7.72E+04 5.40E+02 3.68E+06 2.37E+04 3.24E+03 0.209 0.245 1.493 4.471 P035 Position #3 CTMT AUX Grouted 4.72E+06 1.86E+05 8.21E+07 5.64E+04 3.94E+02 2.68E+06 1.73E+04 2.36E+03 0.152 0.179 1.089 3.262 P035 Position #4 CTMT AUX Grouted 4.39E+06 1.73E+05 7.64E+07 5.24E+04 3.66E+02 2.50E+06 1.61E+04 2.20E+03 0.142 0.166 1.014 3.035 P035 Position #5 CTMT AUX Grouted 4.27E+06 1.68E+05 7.43E+07 5.10E+04 3.56E+02 2.43E+06 1.57E+04 2.14E+03 0.138 0.162 0.986 2.951 P035 Position #6 CTMT AUX Grouted 4.13E+06 1.62E+05 7.18E+07 4.92E+04 3.44E+02 2.34E+06 1.51E+04 2.06E+03 0.133 0.156 0.952 2.850 P035 Position #7 CTMT AUX Grouted 4.01E+06 1.58E+05 6.96E+07 4.78E+04 3.34E+02 2.28E+06 1.47E+04 2.00E+03 0.129 0.152 0.924 2.766 P035 Position #8 CTMT AUX Grouted 4.14E+06 1.63E+05 7.19E+07 4.94E+04 3.45E+02 2.35E+06 1.52E+04 2.07E+03 0.133 0.157 0.954 2.857 P035 Position #9 CTMT AUX Grouted 4.08E+06 1.60E+05 7.09E+07 4.86E+04 3.40E+02 2.32E+06 1.49E+04 2.04E+03 0.132 0.154 0.940 2.815 P035 Position #10 CTMT AUX Grouted 3.90E+06 1.53E+05 6.78E+07 4.65E+04 3.25E+02 2.22E+06 1.43E+04 1.95E+03 0.126 0.148 0.899 2.693 P035 Position #11 CTMT AUX Grouted 3.93E+06 1.55E+05 6.84E+07 4.69E+04 3.28E+02 2.24E+06 1.44E+04 1.97E+03 0.127 0.149 0.907 2.717 P035 Position #12 CTMT AUX Grouted 4.04E+06 1.59E+05 7.02E+07 4.82E+04 3.36E+02 2.29E+06 1.48E+04 2.02E+03 0.130 0.153 0.931 2.787 P035 Position #13 CTMT AUX Grouted 3.98E+06 1.56E+05 6.91E+07 4.74E+04 3.31E+02 2.26E+06 1.46E+04 1.99E+03 0.128 0.150 0.917 2.745 P035 Position #14 CTMT AUX Grouted 4.02E+06 1.58E+05 6.98E+07 4.79E+04 3.35E+02 2.28E+06 1.47E+04 2.01E+03 0.130 0.152 0.926 2.773 P035 Position #15 CTMT AUX Grouted 4.07E+06 1.60E+05 7.08E+07 4.86E+04 3.39E+02 2.31E+06 1.49E+04 2.04E+03 0.131 0.154 0.939 2.812 P035 Position #16 CTMT AUX Grouted 3.99E+06 1.57E+05 6.94E+07 4.76E+04 3.33E+02 2.27E+06 1.46E+04 2.00E+03 0.129 0.151 0.920 2.756 P035 Position #17 CTMT AUX Grouted 3.93E+06 1.55E+05 6.84E+07 4.69E+04 3.28E+02 2.24E+06 1.44E+04 1.97E+03 0.127 0.149 0.907 2.717 P035 Position #18 CTMT AUX Grouted 3.88E+06 1.53E+05 6.75E+07 4.63E+04 3.23E+02 2.20E+06 1.42E+04 1.94E+03 0.125 0.147 0.895 2.679 P035 Position #19 CTMT AUX Grouted 3.82E+06 1.50E+05 6.64E+07 4.56E+04 3.18E+02 2.17E+06 1.40E+04 1.91E+03 0.123 0.144 0.881 2.637 P035 Position #20 CTMT AUX Grouted 3.65E+06 1.44E+05 6.35E+07 4.36E+04 3.04E+02 2.07E+06 1.34E+04 1.83E+03 0.118 0.138 0.842 2.522 P035 Position #21 CTMT AUX Grouted 3.54E+06 1.39E+05 6.16E+07 4.22E+04 2.95E+02 2.01E+06 1.30E+04 1.77E+03 0.114 0.134 0.816 2.445 P035 Position #22 CTMT AUX Grouted 3.57E+06 1.40E+05 6.21E+07 4.26E+04 2.98E+02 2.03E+06 1.31E+04 1.79E+03 0.115 0.135 0.823 2.466 P035 Position #23 CTMT AUX Grouted 3.53E+06 1.39E+05 6.13E+07 4.21E+04 2.94E+02 2.00E+06 1.29E+04 1.76E+03 0.114 0.133 0.813 2.434 P035 Position #24 CTMT AUX Grouted 3.32E+06 1.31E+05 5.78E+07 3.96E+04 2.77E+02 1.89E+06 1.22E+04 1.66E+03 0.107 0.126 0.766 2.295 P035 Position #25 CTMT AUX Grouted 3.45E+06 1.36E+05 6.00E+07 4.12E+04 2.87E+02 1.96E+06 1.26E+04 1.72E+03 0.111 0.130 0.795 2.382 P035 Position #26 CTMT AUX Grouted 3.42E+06 1.34E+05 5.94E+07 4.08E+04 2.85E+02 1.94E+06 1.25E+04 1.71E+03 0.110 0.129 0.788 2.361 P035 Position #27 CTMT AUX Grouted 3.33E+06 1.31E+05 5.80E+07 3.98E+04 2.78E+02 1.89E+06 1.22E+04 1.67E+03 0.108 0.126 0.769 2.302 P035 Position #28 CTMT AUX Grouted 3.45E+06 1.36E+05 6.01E+07 4.12E+04 2.88E+02 1.96E+06 1.27E+04 1.73E+03 0.111 0.131 0.797 2.386 P035 Position #29 CTMT AUX Grouted 3.44E+06 1.35E+05 5.98E+07 4.10E+04 2.87E+02 1.95E+06 1.26E+04 1.72E+03 0.111 0.130 0.793 2.375 P035 Position #30 CTMT AUX Grouted 3.43E+06 1.35E+05 5.97E+07 4.10E+04 2.86E+02 1.95E+06 1.26E+04 1.72E+03 0.111 0.130 0.792 2.372 P035 Position #31 CTMT AUX Grouted 3.52E+06 1.38E+05 6.12E+07 4.20E+04 2.93E+02 2.00E+06 1.29E+04 1.76E+03 0.114 0.133 0.812 2.431 P035 Position #32 CTMT AUX Grouted 3.56E+06 1.40E+05 6.18E+07 4.24E+04 2.96E+02 2.02E+06 1.30E+04 1.78E+03 0.115 0.135 0.820 2.455 P035 Position #33 CTMT AUX Grouted 3.56E+06 1.40E+05 6.18E+07 4.24E+04 2.96E+02 2.02E+06 1.30E+04 1.78E+03 0.115 0.135 0.820 2.455 P035 Position #34 CTMT AUX Grouted 3.73E+06 1.47E+05 6.49E+07 4.45E+04 3.11E+02 2.12E+06 1.37E+04 1.87E+03 0.120 0.141 0.861 2.578 P035 Position #35 CTMT AUX Grouted 3.74E+06 1.47E+05 6.51E+07 4.47E+04 3.12E+02 2.13E+06 1.37E+04 1.87E+03 0.121 0.142 0.863 2.585 P035 Position #36 CTMT AUX Grouted 3.87E+06 1.52E+05 6.74E+07 4.62E+04 3.23E+02 2.20E+06 1.42E+04 1.94E+03 0.125 0.147 0.893 2.675 P035 Position #37 CTMT AUX Grouted 3.84E+06 1.51E+05 6.67E+07 4.58E+04 3.20E+02 2.18E+06 1.41E+04 1.92E+03 0.124 0.145 0.885 2.651 P035 Position #38 CTMT AUX Grouted 3.87E+06 1.52E+05 6.73E+07 4.62E+04 3.22E+02 2.20E+06 1.42E+04 1.93E+03 0.125 0.146 0.892 2.672 P035 Position #39 CTMT AUX Grouted 3.81E+06 1.50E+05 6.63E+07 4.55E+04 3.18E+02 2.17E+06 1.40E+04 1.91E+03 0.123 0.144 0.879 2.634 P035 Position #40 CTMT AUX Grouted 3.79E+06 1.49E+05 6.59E+07 4.52E+04 3.16E+02 2.15E+06 1.39E+04 1.89E+03 0.122 0.143 0.874 2.616 P035 Position #41 CTMT AUX Grouted 3.86E+06 1.52E+05 6.71E+07 4.60E+04 3.22E+02 2.19E+06 1.42E+04 1.93E+03 0.125 0.146 0.890 2.665 P035 Position #42 CTMT AUX Grouted 3.99E+06 1.57E+05 6.93E+07 4.76E+04 3.32E+02 2.26E+06 1.46E+04 1.99E+03 0.129 0.151 0.919 2.752 P035 Position #43 CTMT AUX Grouted 3.90E+06 1.54E+05 6.79E+07 4.66E+04 3.25E+02 2.22E+06 1.43E+04 1.95E+03 0.126 0.148 0.900 2.696 P035 Position #44 CTMT AUX Grouted 4.08E+06 1.60E+05 7.09E+07 4.86E+04 3.40E+02 2.32E+06 1.49E+04 2.04E+03 0.132 0.154 0.940 2.815 P035 Position #45 CTMT AUX Grouted 4.22E+06 1.66E+05 7.34E+07 5.04E+04 3.52E+02 2.40E+06 1.55E+04 2.11E+03 0.136 0.160 0.974 2.916 P035 Position #46 CTMT AUX Grouted 4.23E+06 1.66E+05 7.35E+07 5.04E+04 3.52E+02 2.40E+06 1.55E+04 2.11E+03 0.136 0.160 0.975 2.920 P035 Position #47 CTMT AUX Grouted 4.32E+06 1.70E+05 7.52E+07 5.16E+04 3.60E+02 2.46E+06 1.59E+04 2.16E+03 0.140 0.164 0.997 2.986 P035 Position #48 CTMT AUX Grouted 4.40E+06 1.73E+05 7.65E+07 5.25E+04 3.67E+02 2.50E+06 1.61E+04 2.20E+03 0.142 0.166 1.015 3.039 P035 Position #49 CTMT AUX Grouted 4.55E+06 1.79E+05 7.91E+07 5.43E+04 3.79E+02 2.58E+06 1.67E+04 2.27E+03 0.147 0.172 1.049 3.140 P035 Position #50 CTMT AUX Grouted 4.91E+06 1.93E+05 8.54E+07 5.86E+04 4.09E+02 2.79E+06 1.80E+04 2.46E+03 0.158 0.186 1.132 3.391 MEASUREMENT ID BETWEEN END STATE
~
=ZIONSOLUTIONSuc-An Er,e,,gyS~ Company
FSS RELEASE RECORD, REV 1 PENETRATIONS SURVEY UNITS 01112, 02112 and 05120
[70]
Unit 1 Containment Penetration Measurements (continued)
H-3 (1)
Co-60 (2)
Ni-63 (1)
Sr-90 (1)
Cs-134 (2)
Cs-137 (2)
Eu-152 (2)
Eu-154 (2)
OpSOFPN OpSOFPN OpSOFB OpSOFB (pCi/m2)
(pCi/m2)
(pCi/m2)
(pCi/m2)
(pCi/m2)
(pCi/m2)
(pCi/m2)
(pCi/m2)
CTMTPN Limiting DCGL CTMT DCGL Limiting DCGL P035 Position #51 CTMT AUX Grouted 4.40E+06 1.73E+05 7.65E+07 5.25E+04 3.67E+02 2.50E+06 1.61E+04 2.20E+03 0.142 0.166 1.015 3.039 P003 Position #1 CTMT AUX Removed 1.61E+06 6.33E+04 2.80E+07 1.92E+04 1.34E+02 9.15E+05 5.90E+03 8.05E+02 0.052 0.061 0.371 1.112 P003 Position #2 CTMT AUX Removed 1.91E+06 7.53E+04 3.33E+07 2.28E+04 1.59E+02 1.09E+06 7.02E+03 9.57E+02 0.062 0.072 0.441 1.321 P003 Position #3 CTMT AUX Removed 7.45E+06 2.93E+05 1.30E+08 8.89E+04 6.21E+02 4.23E+06 2.73E+04 3.73E+03 0.240 0.282 1.718 5.146 P050 Position #1 CTMT AUX Removed 4.04E+06 1.59E+05 7.02E+07 4.82E+04 3.37E+02 2.30E+06 1.48E+04 2.02E+03 0.130 0.153 0.931 2.789 P050 Position #2 CTMT AUX Removed 5.25E+06 2.07E+05 9.13E+07 6.26E+04 4.38E+02 2.98E+06 1.93E+04 2.63E+03 0.169 0.199 1.211 3.626 P050 Position #3 CTMT AUX Removed 6.17E+06 2.43E+05 1.07E+08 7.36E+04 5.14E+02 3.50E+06 2.26E+04 3.08E+03 0.199 0.233 1.422 4.259 P087 Position #1 CTMT AUX Removed 7.20E+06 2.83E+05 1.25E+08 8.59E+04 6.00E+02 4.09E+06 2.64E+04 3.60E+03 0.232 0.272 1.660 4.970 P087 Position #2 CTMT AUX Removed 9.19E+06 3.62E+05 1.60E+08 1.10E+05 7.66E+02 5.22E+06 3.37E+04 4.60E+03 0.297 0.348 2.120 6.350 P087 Position #3 CTMT AUX Removed 1.46E+07 5.74E+05 2.54E+08 1.74E+05 1.22E+03 8.29E+06 5.35E+04 7.29E+03 0.471 0.552 3.363 10.071 P064 Position #1 CTMT AUX Removed 5.56E+06 2.19E+05 9.67E+07 6.64E+04 4.64E+02 3.16E+06 2.04E+04 2.78E+03 0.180 0.210 1.283 3.842 P064 Position #2 CTMT AUX Removed 6.07E+06 2.39E+05 1.06E+08 7.25E+04 5.06E+02 3.45E+06 2.23E+04 3.04E+03 0.196 0.230 1.401 4.194 P064 Position #3 CTMT AUX Removed 7.94E+06 3.12E+05 1.38E+08 9.47E+04 6.62E+02 4.51E+06 2.91E+04 3.97E+03 0.256 0.300 1.830 5.481 P018 By Direct Scan CTMT AUX Removed 1.06E+07 4.17E+05 1.84E+08 1.26E+05 8.83E+02 6.02E+06 3.89E+04 5.30E+03 0.342 0.401 2.444 7.319 P090 By Direct Scan CTMT AUX Removed 9.23E+06 3.63E+05 1.61E+08 1.10E+05 7.70E+02 5.25E+06 3.39E+04 4.62E+03 0.298 0.349 2.129 6.376 P020 By Direct Scan CTMT AUX Removed 2.73E+07 1.07E+06 4.75E+08 3.26E+05 2.28E+03 1.55E+07 1.00E+05 1.37E+04 0.882 1.034 6.301 18.870 P021 By Direct Scan CTMT AUX Removed 4.57E+07 1.80E+06 7.95E+08 5.45E+05 3.81E+03 2.60E+07 1.68E+05 2.29E+04 1.475 1.729 10.541 31.568 P067 By Direct Scan CTMT AUX Removed 3.36E+06 1.32E+05 5.84E+07 4.00E+04 2.80E+02 1.91E+06 1.23E+04 1.68E+03 0.108 0.127 0.774 2.317 P073 By Direct Scan CTMT AUX Removed 5.78E+06 2.27E+05 1.00E+08 6.89E+04 4.81E+02 3.28E+06 2.12E+04 2.89E+03 0.186 0.218 1.332 3.989 P105 By Direct Scan CTMT AUX Removed 1.76E+06 6.93E+04 3.06E+07 2.10E+04 1.47E+02 1.00E+06 6.46E+03 8.81E+02 0.057 0.067 0.406 1.217 P068 By Direct Scan CTMT AUX Removed 1.09E+05 4.29E+03 1.89E+06 1.30E+03 9.08E+00 6.19E+04 4.00E+02 5.45E+01 0.004 0.004 0.025 0.075 P070 By Direct Scan CTMT AUX Removed 2.79E+05 1.10E+04 4.85E+06 3.33E+03 2.33E+01 1.59E+05 1.02E+03 1.40E+02 0.009 0.011 0.064 0.193 P069 By Direct Scan CTMT AUX Removed 1.31E+05 5.17E+03 2.28E+06 1.57E+03 1.09E+01 7.46E+04 4.82E+02 6.57E+01 0.004 0.005 0.030 0.091 P066 By Direct Scan CTMT AUX Removed 1.17E+05 4.61E+03 2.04E+06 1.40E+03 9.77E+00 6.66E+04 4.30E+02 5.86E+01 0.004 0.004 0.027 0.081 P017 By Direct Scan CTMT AUX Removed 1.27E+05 5.01E+03 2.21E+06 1.52E+03 1.06E+01 7.23E+04 4.67E+02 6.36E+01 0.004 0.005 0.029 0.088 P103 Position #1 CTMT AUX Removed 9.35E+06 3.68E+05 1.63E+08 1.12E+05 7.80E+02 5.31E+06 3.43E+04 4.68E+03 0.302 0.354 2.157 6.459 P103 Position #2 CTMT AUX Removed 3.80E+06 1.49E+05 6.60E+07 4.53E+04 3.16E+02 2.16E+06 1.39E+04 1.90E+03 0.123 0.144 0.876 2.622 P103 Position #3 CTMT AUX Removed 2.58E+06 1.01E+05 4.49E+07 3.08E+04 2.15E+02 1.47E+06 9.46E+03 1.29E+03 0.083 0.098 0.595 1.782 P103 Position #4 CTMT AUX Removed 2.19E+06 8.63E+04 3.81E+07 2.62E+04 1.83E+02 1.25E+06 8.04E+03 1.10E+03 0.071 0.083 0.506 1.514 P103 Position #5 CTMT AUX Removed 2.54E+06 1.00E+05 4.42E+07 3.03E+04 2.12E+02 1.44E+06 9.32E+03 1.27E+03 0.082 0.096 0.586 1.755 P056 Position #1 CTMT AUX Removed 1.17E+07 4.61E+05 2.04E+08 1.40E+05 9.76E+02 6.65E+06 4.29E+04 5.86E+03 0.378 0.443 2.701 8.088 P056 Position #2 CTMT AUX Removed 2.88E+06 1.13E+05 5.00E+07 3.43E+04 2.40E+02 1.63E+06 1.06E+04 1.44E+03 0.093 0.109 0.663 1.987 P056 Position #3 CTMT AUX Removed 1.74E+06 6.85E+04 3.03E+07 2.08E+04 1.45E+02 9.89E+05 6.39E+03 8.71E+02 0.056 0.066 0.402 1.202 P056 Position #4 CTMT AUX Removed 1.42E+06 5.58E+04 2.47E+07 1.69E+04 1.18E+02 8.06E+05 5.20E+03 7.09E+02 0.046 0.054 0.327 0.979 P056 Position #5 CTMT AUX Removed 1.40E+06 5.52E+04 2.44E+07 1.67E+04 1.17E+02 7.98E+05 5.15E+03 7.02E+02 0.045 0.053 0.324 0.969 P012 By Direct Scan CTMT AUX Removed 2.09E+05 8.24E+03 3.64E+06 2.50E+03 1.75E+01 1.19E+05 7.68E+02 1.05E+02 0.007 0.008 0.048 0.145 P005 By Direct Scan CTMT TB Open/Buried 8.16E+04 3.21E+03 1.42E+06 9.73E+02 6.80E+00 4.64E+04 2.99E+02 4.08E+01 0.003 0.003 0.019 0.056 P009 By Direct Scan CTMT TB Open/Buried 8.75E+04 3.44E+03 1.52E+06 1.04E+03 7.29E+00 4.97E+04 3.21E+02 4.37E+01 0.003 0.003 0.020 0.060 P112 By Direct Scan CTMT TB Open/Buried 8.75E+04 3.44E+03 1.52E+06 1.04E+03 7.29E+00 4.97E+04 3.21E+02 4.37E+01 0.003 0.003 0.020 0.060 P094 By Direct Scan CTMT TB Open/Buried 9.01E+04 3.55E+03 1.57E+06 1.08E+03 7.51E+00 5.12E+04 3.31E+02 4.51E+01 0.003 0.003 0.021 0.062 P007 By Direct Scan CTMT TB Open/Buried 7.98E+04 3.14E+03 1.39E+06 9.52E+02 6.65E+00 4.53E+04 2.93E+02 3.99E+01 0.003 0.003 0.018 0.055 P007 By Direct Scan CTMT TB Open/Buried 3.68E+04 1.45E+03 6.40E+05 4.39E+02 3.07E+00 2.09E+04 1.35E+02 1.84E+01 0.001 0.001 0.008 0.025 P116 By Direct Scan CTMT TB Open/Buried 6.07E+04 2.39E+03 1.05E+06 7.24E+02 5.06E+00 3.45E+04 2.23E+02 3.03E+01 0.002 0.002 0.014 0.042 P011 By Direct Scan CTMT TB Open/Buried 4.09E+04 1.61E+03 7.12E+05 4.88E+02 3.41E+00 2.33E+04 1.50E+02 2.05E+01 0.001 0.002 0.009 0.028 P097 By Direct Scan CTMT TB Open/Buried 6.01E+04 2.36E+03 1.04E+06 7.17E+02 5.01E+00 3.41E+04 2.20E+02 3.00E+01 0.002 0.002 0.014 0.041 P128 By Direct Scan CTMT TB Open/Buried 7.30E+04 2.87E+03 1.27E+06 8.72E+02 6.09E+00 4.15E+04 2.68E+02 3.65E+01 0.002 0.003 0.017 0.050 P012 By Direct Scan CTMT TB Open/Buried 2.09E+05 8.24E+03 3.64E+06 2.50E+03 1.75E+01 1.19E+05 7.68E+02 1.05E+02 0.007 0.008 0.048 0.145 P008 By Direct Scan CTMT TB Open/Buried 1.19E+05 4.68E+03 2.07E+06 1.42E+03 9.92E+00 6.76E+04 4.36E+02 5.95E+01 0.004 0.005 0.027 0.082 P117 By Direct Scan CTMT TB Open/Buried 7.04E+04 2.77E+03 1.22E+06 8.40E+02 5.87E+00 4.00E+04 2.58E+02 3.52E+01 0.002 0.003 0.016 0.049 P113 By Direct Scan CTMT TB Open/Buried 5.04E+04 1.98E+03 8.76E+05 6.01E+02 4.20E+00 2.86E+04 1.85E+02 2.52E+01 0.002 0.002 0.012 0.035 P115 By Direct Scan CTMT TB Open/Buried 1.24E+05 4.87E+03 2.15E+06 1.48E+03 1.03E+01 7.03E+04 4.54E+02 6.19E+01 0.004 0.005 0.029 0.085 MEASUREMENT ID BETWEEN END STATE
~
=ZIONSOLUTIONSuc-An Er,e,,gyS~ Company
FSS RELEASE RECORD, REV 1 PENETRATIONS SURVEY UNITS 01112, 02112 and 05120
[71]
Unit 1 Containment Penetration Measurements (continued)
H-3 (1)
Co-60 (2)
Ni-63 (1)
Sr-90 (1)
Cs-134 (2)
Cs-137 (2)
Eu-152 (2)
Eu-154 (2)
OpSOFPN OpSOFPN OpSOFB OpSOFB (pCi/m2)
(pCi/m2)
(pCi/m2)
(pCi/m2)
(pCi/m2)
(pCi/m2)
(pCi/m2)
(pCi/m2)
CTMTPN Limiting DCGL CTMT DCGL Limiting DCGL P093 By Direct Scan CTMT TB Open/Buried 1.70E+05 6.70E+03 2.96E+06 2.03E+03 1.42E+01 9.67E+04 6.24E+02 8.51E+01 0.005 0.006 0.039 0.118 P006 By Direct Scan CTMT TB Open/Buried 1.17E+05 4.59E+03 2.03E+06 1.39E+03 9.72E+00 6.63E+04 4.28E+02 5.83E+01 0.004 0.004 0.027 0.081 P096 By Direct Scan CTMT TB Open/Buried 6.98E+04 2.75E+03 1.21E+06 8.33E+02 5.82E+00 3.97E+04 2.56E+02 3.49E+01 0.002 0.003 0.016 0.048 P010 By Direct Scan CTMT TB Open/Buried 1.05E+05 4.14E+03 1.83E+06 1.25E+03 8.76E+00 5.97E+04 3.86E+02 5.26E+01 0.003 0.004 0.024 0.073 P095 By Direct Scan CTMT TB Open/Buried 6.10E+04 2.40E+03 1.06E+06 7.27E+02 5.08E+00 3.46E+04 2.24E+02 3.05E+01 0.002 0.002 0.014 0.042 P127 By Direct Scan CTMT TB Open/Buried 1.08E+05 4.25E+03 1.88E+06 1.29E+03 9.01E+00 6.14E+04 3.96E+02 5.41E+01 0.003 0.004 0.025 0.075 P092 By Direct Scan CTMT TB Open/Buried 6.07E+04 2.39E+03 1.05E+06 7.24E+02 5.06E+00 3.45E+04 2.23E+02 3.03E+01 0.002 0.002 0.014 0.042 P091 By Direct Scan CTMT TB Open/Buried 7.36E+04 2.90E+03 1.28E+06 8.79E+02 6.14E+00 4.18E+04 2.70E+02 3.68E+01 0.002 0.003 0.017 0.051 P098 By Direct Scan CTMT TB Open/Buried 6.33E+04 2.49E+03 1.10E+06 7.56E+02 5.28E+00 3.60E+04 2.32E+02 3.17E+01 0.002 0.002 0.015 0.044 P118 By Direct Scan CTMT TB Open/Buried 6.39E+04 2.51E+03 1.11E+06 7.63E+02 5.33E+00 3.63E+04 2.34E+02 3.20E+01 0.002 0.002 0.015 0.044 MEASUREMENT ID BETWEEN END STATE
~
=ZIONSOLUTIONSuc-An Er,e,,gyS~ Company
FSS RELEASE RECORD, REV 1 PENETRATIONS SURVEY UNITS 01112, 02112 and 05120
[72]
Unit 1 Containment - Elevated Measurement Calculation 242.360 m2 1.096 m2 H-3 Co-60 Ni-63 Sr-90 Cs-134 Cs-137 Eu-152 Eu-154 (pCi/m2)
(pCi/m2)
(pCi/m2)
(pCi/m2)
(pCi/m2)
(pCi/m2)
(pCi/m2)
(pCi/m2)
P123 Position #1 CTMT AUX Grouted 2.13E+08 8.37E+06 3.70E+09 2.54E+06 1.77E+04 1.21E+08 7.80E+05 1.06E+05 LimitingPN DCGLs 0.000 0.000 0.000 0.001 0.000 0.001 0.000 0.000 0.002 P123 Position #2 CTMT AUX Grouted 2.42E+08 9.53E+06 4.21E+09 2.89E+06 2.02E+04 1.38E+08 8.89E+05 1.21E+05 LimitingPN DCGLs 0.000 0.000 0.000 0.001 0.000 0.001 0.000 0.000 0.003 P123 Position #3 CTMT AUX Grouted 2.67E+08 1.05E+07 4.63E+09 3.18E+06 2.22E+04 1.51E+08 9.77E+05 1.33E+05 LimitingPN DCGLs 0.000 0.001 0.000 0.001 0.000 0.001 0.000 0.000 0.003 P123 Position #4 CTMT AUX Grouted 2.58E+08 1.01E+07 4.48E+09 3.07E+06 2.15E+04 1.46E+08 9.44E+05 1.29E+05 LimitingPN DCGLs 0.000 0.000 0.000 0.001 0.000 0.001 0.000 0.000 0.003 P123 Position #5 CTMT AUX Grouted 2.37E+08 9.31E+06 4.11E+09 2.82E+06 1.97E+04 1.34E+08 8.68E+05 1.18E+05 LimitingPN DCGLs 0.000 0.000 0.000 0.001 0.000 0.001 0.000 0.000 0.003 P123 Position #6 CTMT AUX Grouted 2.10E+08 8.25E+06 3.65E+09 2.50E+06 1.75E+04 1.19E+08 7.69E+05 1.05E+05 LimitingPN DCGLs 0.000 0.000 0.000 0.001 0.000 0.001 0.000 0.000 0.002 P123 Position #7 CTMT AUX Grouted 1.96E+08 7.71E+06 3.41E+09 2.34E+06 1.63E+04 1.11E+08 7.18E+05 9.80E+04 LimitingPN DCGLs 0.000 0.000 0.000 0.000 0.000 0.001 0.000 0.000 0.002 P123 Position #8 CTMT AUX Grouted 1.83E+08 7.21E+06 3.19E+09 2.19E+06 1.53E+04 1.04E+08 6.72E+05 9.17E+04 LimitingPN DCGLs 0.000 0.000 0.000 0.000 0.000 0.001 0.000 0.000 0.002 P123 Position #9 CTMT AUX Grouted 1.73E+08 6.80E+06 3.01E+09 2.06E+06 1.44E+04 9.83E+07 6.34E+05 8.65E+04 LimitingPN DCGLs 0.000 0.000 0.000 0.000 0.000 0.001 0.000 0.000 0.002 P123 Position #10 CTMT AUX Grouted 1.84E+08 7.26E+06 3.21E+09 2.20E+06 1.54E+04 1.05E+08 6.76E+05 9.22E+04 LimitingPN DCGLs 0.000 0.000 0.000 0.000 0.000 0.001 0.000 0.000 0.002 MEASUREMENT ID BETWEEN END STATE BcSOFADJ Survey Unit Area Elevated Area (LTP Ch 6 Table 6-50, Release Record Table 1)
(FOV of Detector in Pipe at 1 ft increments)
~
= ZIONSOLUTIONSuc-An Er,e,,gyS~ Company 7
7 7
7
FSS RELEASE RECORD, REV 1 PENETRATIONS SURVEY UNITS 01112, 02112 and 05120
[73]
Unit 1 Containment - Elevated Measurement Calculation (continued)
P123 Position #11 CTMT AUX Grouted 1.93E+08 7.61E+06 3.36E+09 2.31E+06 1.61E+04 1.10E+08 7.10E+05 9.68E+04 LimitingPN DCGLs 0.000 0.000 0.000 0.000 0.000 0.001 0.000 0.000 0.002 P123 Position #12 CTMT AUX Grouted 1.93E+08 7.60E+06 3.36E+09 2.30E+06 1.61E+04 1.10E+08 7.08E+05 9.66E+04 LimitingPN DCGLs 0.000 0.000 0.000 0.000 0.000 0.001 0.000 0.000 0.002 P123 Position #13 CTMT AUX Grouted 2.03E+08 7.99E+06 3.53E+09 2.42E+06 1.69E+04 1.15E+08 7.45E+05 1.02E+05 LimitingPN DCGLs 0.000 0.000 0.000 0.001 0.000 0.001 0.000 0.000 0.002 P123 Position #14 CTMT AUX Grouted 1.81E+08 7.13E+06 3.15E+09 2.16E+06 1.51E+04 1.03E+08 6.64E+05 9.06E+04 LimitingPN DCGLs 0.000 0.000 0.000 0.000 0.000 0.001 0.000 0.000 0.002 P123 Position #15 CTMT AUX Grouted 1.41E+08 5.54E+06 2.45E+09 1.68E+06 1.17E+04 8.00E+07 5.16E+05 7.04E+04 LimitingPN DCGLs 0.000 0.000 0.000 0.000 0.000 0.001 0.000 0.000 0.002 P123 Position #16 CTMT AUX Grouted 1.19E+08 4.68E+06 2.07E+09 1.42E+06 9.92E+03 6.76E+07 4.37E+05 5.95E+04 LimitingPN DCGLs 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.001 P123 Position #17 CTMT AUX Grouted 1.11E+08 4.37E+06 1.93E+09 1.32E+06 9.25E+03 6.31E+07 4.07E+05 5.55E+04 LimitingPN DCGLs 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.001 P123 Position #18 CTMT AUX Grouted 1.07E+08 4.21E+06 1.86E+09 1.28E+06 8.93E+03 6.09E+07 3.93E+05 5.36E+04 LimitingPN DCGLs 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.001 P123 Position #19 CTMT AUX Grouted 1.11E+08 4.35E+06 1.92E+09 1.32E+06 9.22E+03 6.29E+07 4.06E+05 5.53E+04 LimitingPN DCGLs 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.001 P123 Position #20 CTMT AUX Grouted 8.98E+07 3.53E+06 1.56E+09 1.07E+06 7.48E+03 5.10E+07 3.29E+05 4.49E+04 LimitingPN DCGLs 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.001 P123 Position #21 CTMT AUX Grouted 6.62E+07 2.61E+06 1.15E+09 7.90E+05 5.52E+03 3.76E+07 2.43E+05 3.31E+04 LimitingPN DCGLs 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.001 P123 Position #22 CTMT AUX Grouted 5.80E+07 2.28E+06 1.01E+09 6.92E+05 4.83E+03 3.29E+07 2.13E+05 2.90E+04 LimitingPN DCGLs 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.001
~
= ZIONSOLUTIONSuc-An Er,e,,gyS~ Company l
I J
J I
7 I
I J
I I
I I
7 I
I I
I I
I I
7 I
I
FSS RELEASE RECORD, REV 1 PENETRATIONS SURVEY UNITS 01112, 02112 and 05120
[74]
Unit 1 Containment - Elevated Measurement Calculation (continued)
P123 Position #23 CTMT AUX Grouted 4.22E+07 1.66E+06 7.34E+08 5.04E+05 3.52E+03 2.40E+07 1.55E+05 2.11E+04 LimitingPN DCGLs 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 P124 Position #1 CTMT AUX Grouted 8.20E+07 3.23E+06 1.43E+09 9.79E+05 6.84E+03 4.66E+07 3.01E+05 4.10E+04 LimitingPN DCGLs 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.001 P124 Position #2 CTMT AUX Grouted 6.80E+07 2.68E+06 1.18E+09 8.11E+05 5.67E+03 3.86E+07 2.49E+05 3.40E+04 LimitingPN DCGLs 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.001 P124 Position #3 CTMT AUX Grouted 7.10E+07 2.80E+06 1.24E+09 8.48E+05 5.92E+03 4.04E+07 2.61E+05 3.55E+04 LimitingPN DCGLs 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.001 P124 Position #4 CTMT AUX Grouted 7.18E+07 2.83E+06 1.25E+09 8.57E+05 5.99E+03 4.08E+07 2.63E+05 3.59E+04 LimitingPN DCGLs 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.001 P124 Position #5 CTMT AUX Grouted 7.08E+07 2.79E+06 1.23E+09 8.45E+05 5.90E+03 4.02E+07 2.60E+05 3.54E+04 LimitingPN DCGLs 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.001 P124 Position #6 CTMT AUX Grouted 6.72E+07 2.64E+06 1.17E+09 8.02E+05 5.60E+03 3.82E+07 2.46E+05 3.36E+04 LimitingPN DCGLs 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.001 P124 Position #7 CTMT AUX Grouted 5.96E+07 2.35E+06 1.04E+09 7.12E+05 4.97E+03 3.39E+07 2.19E+05 2.98E+04 LimitingPN DCGLs 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.001 P124 Position #8 CTMT AUX Grouted 5.76E+07 2.27E+06 1.00E+09 6.87E+05 4.80E+03 3.27E+07 2.11E+05 2.88E+04 LimitingPN DCGLs 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.001 P124 Position #9 CTMT AUX Grouted 5.79E+07 2.28E+06 1.01E+09 6.91E+05 4.83E+03 3.29E+07 2.12E+05 2.90E+04 LimitingPN DCGLs 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.001 P124 Position #10 CTMT AUX Grouted 5.90E+07 2.32E+06 1.03E+09 7.04E+05 4.92E+03 3.35E+07 2.16E+05 2.95E+04 LimitingPN DCGLs 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.001 P124 Position #11 CTMT AUX Grouted 6.11E+07 2.40E+06 1.06E+09 7.29E+05 5.09E+03 3.47E+07 2.24E+05 3.05E+04 LimitingPN DCGLs 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.001 P124 Position #12 CTMT AUX Grouted 6.22E+07 2.45E+06 1.08E+09 7.42E+05 5.18E+03 3.53E+07 2.28E+05 3.11E+04 LimitingPN DCGLs 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.001
~
= ZIONSOLUTIONSuc-An Er,e,,gyS~ Company l
I J
J I
7 I
I J
I I
I I
7 I
I I
I I
I I
7 I
I I
I
FSS RELEASE RECORD, REV 1 PENETRATIONS SURVEY UNITS 01112, 02112 and 05120
[75]
Unit 1 Containment - Elevated Measurement Calculation (continued)
Unit 1 Containment - Elevated Measurement Calculation LTP Chapter 5, Equation 5-6 P124 Position #13 CTMT AUX Grouted 6.30E+07 2.48E+06 1.09E+09 7.51E+05 5.25E+03 3.58E+07 2.31E+05 3.15E+04 LimitingPN DCGLs 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.001 P124 Position #14 CTMT AUX Grouted 6.56E+07 2.58E+06 1.14E+09 7.82E+05 5.47E+03 3.73E+07 2.40E+05 3.28E+04 LimitingPN DCGLs 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.001 P124 Position #15 CTMT AUX Grouted 6.30E+07 2.48E+06 1.10E+09 7.52E+05 5.25E+03 3.58E+07 2.31E+05 3.15E+04 LimitingPN DCGLs 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.001 P124 Position #16 CTMT AUX Grouted 5.04E+07 1.98E+06 8.76E+08 6.01E+05 4.20E+03 2.86E+07 1.85E+05 2.52E+04 LimitingPN DCGLs 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 P124 Position #17 CTMT AUX Grouted 4.42E+07 1.74E+06 7.69E+08 5.28E+05 3.69E+03 2.51E+07 1.62E+05 2.21E+04 LimitingPN DCGLs 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 P124 Position #18 CTMT AUX Grouted 4.10E+07 1.61E+06 7.13E+08 4.89E+05 3.42E+03 2.33E+07 1.50E+05 2.05E+04 LimitingPN DCGLs 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 P124 Position #19 CTMT AUX Grouted 3.55E+07 1.40E+06 6.17E+08 4.24E+05 2.96E+03 2.02E+07 1.30E+05 1.78E+04 LimitingPN DCGLs 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 P021 By Direct Scan CTMT AUX Removed 4.57E+07 1.80E+06 7.95E+08 5.45E+05 3.81E+03 2.60E+07 1.68E+05 2.29E+04 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 LimitingPN DCGLs
~
= ZIONSOLUTIONSuc-An Er,e,,gyS~ Company l
I J
J I
7 I
I J
I I
I l
11 Mean ConcsP/PN (Elev Concspf PN
- Mea11 Concspf PN )
R0q R0q R0q SOFEP/PN = -----+
=* BcDCGLsp/ PN Roe*
[BcDCGL
. x ( ~ su )]
1 1 t
EP/PN ROG \\sA t
Elev
FSS RELEASE RECORD, REV 1 PENETRATIONS SURVEY UNITS 01112, 02112 and 05120
[76]
Unit 2 Containment Penetration Measurements H-3 (1)
Co-60 (2)
Ni-63 (1)
Sr-90 (1)
Cs-134 (2)
Cs-137 (2)
Eu-152 (2)
Eu-154 (2)
OpSOFPN OpSOFPN OpSOFB OpSOFB (pCi/m2)
(pCi/m2)
(pCi/m2)
(pCi/m2)
(pCi/m2)
(pCi/m2)
(pCi/m2)
(pCi/m2)
CTMTPN Limiting DCGL CTMT DCGL Limiting DCGL P201 Position #1 CTMT AUX Removed 2.12E+07 8.35E+05 3.69E+08 2.53E+05 1.77E+03 1.21E+07 7.78E+04 1.06E+04 0.685 0.803 4.895 14.658 P201 Position #2 CTMT AUX Removed 2.93E+06 1.15E+05 5.10E+07 3.50E+04 2.45E+02 1.67E+06 1.08E+04 1.47E+03 0.095 0.111 0.677 2.026 P201 Position #3 CTMT AUX Removed 1.87E+06 7.36E+04 3.25E+07 2.23E+04 1.56E+02 1.06E+06 6.86E+03 9.35E+02 0.060 0.071 0.431 1.291 P201 Position #4 CTMT AUX Removed 1.87E+06 7.34E+04 3.24E+07 2.23E+04 1.55E+02 1.06E+06 6.84E+03 9.33E+02 0.060 0.071 0.430 1.288 P250 Position #1 CTMT AUX Removed 1.64E+06 6.45E+04 2.85E+07 1.96E+04 1.37E+02 9.32E+05 6.01E+03 8.20E+02 0.053 0.062 0.378 1.133 P250 Position #2 CTMT AUX Removed 1.72E+06 6.79E+04 3.00E+07 2.06E+04 1.44E+02 9.80E+05 6.33E+03 8.63E+02 0.056 0.065 0.398 1.191 P250 Position #3 CTMT AUX Removed 1.85E+06 7.28E+04 3.22E+07 2.21E+04 1.54E+02 1.05E+06 6.78E+03 9.25E+02 0.060 0.070 0.427 1.277 P250 Position #4 CTMT AUX Removed 2.13E+06 8.36E+04 3.70E+07 2.54E+04 1.77E+02 1.21E+06 7.79E+03 1.06E+03 0.069 0.080 0.490 1.468 P250 Position #5 CTMT AUX Removed 4.06E+06 1.60E+05 7.06E+07 4.84E+04 3.38E+02 2.31E+06 1.49E+04 2.03E+03 0.131 0.154 0.936 2.803 P287 Position #1 CTMT AUX Removed 1.24E+06 4.89E+04 2.16E+07 1.48E+04 1.04E+02 7.07E+05 4.56E+03 6.22E+02 0.040 0.047 0.287 0.859 P287 Position #2 CTMT AUX Removed 1.55E+06 6.10E+04 2.69E+07 1.85E+04 1.29E+02 8.80E+05 5.68E+03 7.75E+02 0.050 0.059 0.357 1.070 P287 Position #3 CTMT AUX Removed 1.77E+06 6.96E+04 3.08E+07 2.11E+04 1.47E+02 1.00E+06 6.49E+03 8.85E+02 0.057 0.067 0.408 1.222 P287 Position #4 CTMT AUX Removed 2.16E+06 8.48E+04 3.75E+07 2.57E+04 1.80E+02 1.22E+06 7.91E+03 1.08E+03 0.070 0.082 0.497 1.489 P287 Position #5 CTMT AUX Removed 5.72E+06 2.25E+05 9.95E+07 6.83E+04 4.77E+02 3.25E+06 2.10E+04 2.86E+03 0.185 0.217 1.320 3.953 P203 Position #1 CTMT AUX Removed 2.79E+06 1.10E+05 4.86E+07 3.33E+04 2.33E+02 1.59E+06 1.02E+04 1.40E+03 0.090 0.106 0.644 1.930 P203 Position #2 CTMT AUX Removed 1.63E+06 6.40E+04 2.83E+07 1.94E+04 1.36E+02 9.24E+05 5.96E+03 8.13E+02 0.052 0.062 0.375 1.123 P203 Position #3 CTMT AUX Removed 1.45E+06 5.69E+04 2.52E+07 1.73E+04 1.21E+02 8.22E+05 5.31E+03 7.24E+02 0.047 0.055 0.334 0.999 P203 Position #4 CTMT AUX Removed 1.28E+06 5.03E+04 2.22E+07 1.53E+04 1.07E+02 7.27E+05 4.69E+03 6.40E+02 0.041 0.048 0.295 0.884 P203 Position #5 CTMT AUX Removed 3.16E+06 1.24E+05 5.50E+07 3.78E+04 2.64E+02 1.80E+06 1.16E+04 1.58E+03 0.102 0.120 0.730 2.185 P264 Position #1 CTMT AUX Removed 1.82E+06 7.16E+04 3.17E+07 2.17E+04 1.52E+02 1.03E+06 6.68E+03 9.11E+02 0.059 0.069 0.420 1.258 P264 Position #2 CTMT AUX Removed 1.78E+06 7.02E+04 3.10E+07 2.13E+04 1.49E+02 1.01E+06 6.54E+03 8.92E+02 0.058 0.067 0.411 1.232 P264 Position #3 CTMT AUX Removed 1.65E+06 6.49E+04 2.87E+07 1.97E+04 1.38E+02 9.38E+05 6.05E+03 8.25E+02 0.053 0.062 0.381 1.140 P264 Position #4 CTMT AUX Removed 1.70E+06 6.67E+04 2.95E+07 2.02E+04 1.41E+02 9.64E+05 6.22E+03 8.48E+02 0.055 0.064 0.391 1.172 P264 Position #5 CTMT AUX Removed 5.13E+06 2.02E+05 8.93E+07 6.12E+04 4.28E+02 2.92E+06 1.88E+04 2.57E+03 0.166 0.194 1.184 3.545 P267 By Direct Scan CTMT AUX Removed 8.06E+04 3.17E+03 1.40E+06 9.62E+02 6.72E+00 4.58E+04 2.96E+02 4.03E+01 0.003 0.003 0.019 0.056 P273 By Direct Scan CTMT AUX Removed 5.02E+05 1.98E+04 8.73E+06 5.99E+03 4.19E+01 2.85E+05 1.84E+03 2.51E+02 0.016 0.019 0.116 0.347 P218 By Direct Scan CTMT AUX Removed 3.39E+05 1.34E+04 5.90E+06 4.05E+03 2.83E+01 1.93E+05 1.24E+03 1.70E+02 0.011 0.013 0.078 0.234 P254 Position #1 CTMT AUX Removed 3.71E+06 1.46E+05 6.45E+07 4.43E+04 3.09E+02 2.11E+06 1.36E+04 1.86E+03 0.120 0.140 0.856 2.563 P254 Position #2 CTMT AUX Removed 1.40E+06 5.50E+04 2.43E+07 1.67E+04 1.17E+02 7.95E+05 5.13E+03 7.00E+02 0.045 0.053 0.323 0.966 P254 Position #3 CTMT AUX Removed 1.29E+06 5.08E+04 2.24E+07 1.54E+04 1.08E+02 7.33E+05 4.73E+03 6.45E+02 0.042 0.049 0.298 0.891 P254 Position #4 CTMT AUX Removed 1.34E+06 5.27E+04 2.33E+07 1.60E+04 1.12E+02 7.60E+05 4.91E+03 6.69E+02 0.043 0.051 0.309 0.924 P217 By Direct Scan CTMT AUX Removed 1.11E+05 4.36E+03 1.93E+06 1.32E+03 9.23E+00 6.29E+04 4.06E+02 5.54E+01 0.004 0.004 0.026 0.076 P221 By Direct Scan CTMT AUX Removed 8.57E+04 3.37E+03 1.49E+06 1.02E+03 7.14E+00 4.87E+04 3.14E+02 4.29E+01 0.003 0.003 0.020 0.059 P290 By Direct Scan CTMT AUX Removed 1.09E+05 4.30E+03 1.90E+06 1.30E+03 9.11E+00 6.21E+04 4.01E+02 5.46E+01 0.004 0.004 0.025 0.075 P305 By Direct Scan CTMT AUX Removed 1.17E+05 4.59E+03 2.03E+06 1.39E+03 9.72E+00 6.63E+04 4.28E+02 5.83E+01 0.004 0.004 0.027 0.081 P286 Position #1 CTMT AUX Removed 1.52E+07 5.97E+05 2.64E+08 1.81E+05 1.26E+03 8.62E+06 5.56E+04 7.58E+03 0.489 0.574 3.498 10.474 P286 Position #2 CTMT AUX Removed 3.00E+06 1.18E+05 5.22E+07 3.58E+04 2.50E+02 1.71E+06 1.10E+04 1.50E+03 0.097 0.114 0.692 2.073 P286 Position #3 CTMT AUX Removed 2.26E+06 8.89E+04 3.93E+07 2.69E+04 1.88E+02 1.28E+06 8.28E+03 1.13E+03 0.073 0.085 0.521 1.560 P286 Position #4 CTMT AUX Removed 2.07E+06 8.14E+04 3.60E+07 2.47E+04 1.72E+02 1.17E+06 7.58E+03 1.03E+03 0.067 0.078 0.477 1.428 P289 Position #1 CTMT AUX Removed 6.05E+06 2.38E+05 1.05E+08 7.21E+04 5.04E+02 3.43E+06 2.22E+04 3.02E+03 0.195 0.229 1.394 4.175 P289 Position #2 CTMT AUX Removed 2.06E+06 8.10E+04 3.58E+07 2.46E+04 1.72E+02 1.17E+06 7.55E+03 1.03E+03 0.066 0.078 0.475 1.421 P289 Position #3 CTMT AUX Removed 1.76E+06 6.93E+04 3.06E+07 2.10E+04 1.47E+02 1.00E+06 6.46E+03 8.81E+02 0.057 0.067 0.406 1.217 P289 Position #4 CTMT AUX Removed 2.17E+06 8.53E+04 3.77E+07 2.59E+04 1.81E+02 1.23E+06 7.95E+03 1.08E+03 0.070 0.082 0.500 1.497 P288 Position #1 CTMT AUX Removed 1.01E+07 3.98E+05 1.76E+08 1.21E+05 8.43E+02 5.75E+06 3.71E+04 5.06E+03 0.326 0.383 2.332 6.985 P288 Position #2 CTMT AUX Removed 2.14E+06 8.43E+04 3.72E+07 2.56E+04 1.79E+02 1.22E+06 7.86E+03 1.07E+03 0.069 0.081 0.494 1.479 P288 Position #3 CTMT AUX Removed 1.61E+06 6.32E+04 2.79E+07 1.92E+04 1.34E+02 9.13E+05 5.89E+03 8.04E+02 0.052 0.061 0.371 1.110 P288 Position #4 CTMT AUX Removed 1.86E+06 7.32E+04 3.24E+07 2.22E+04 1.55E+02 1.06E+06 6.83E+03 9.31E+02 0.060 0.070 0.429 1.285 P219 Position #1 CTMT AUX Removed 7.12E+06 2.80E+05 1.24E+08 8.49E+04 5.93E+02 4.04E+06 2.61E+04 3.56E+03 0.230 0.269 1.641 4.915 P219 Position #2 CTMT AUX Removed 2.33E+06 9.15E+04 4.04E+07 2.78E+04 1.94E+02 1.32E+06 8.53E+03 1.16E+03 0.075 0.088 0.536 1.606 P219 Position #3 CTMT AUX Removed 2.21E+06 8.68E+04 3.84E+07 2.63E+04 1.84E+02 1.25E+06 8.09E+03 1.10E+03 0.071 0.083 0.509 1.524 P219 Position #4 CTMT AUX Removed 2.65E+06 1.04E+05 4.61E+07 3.17E+04 2.21E+02 1.51E+06 9.73E+03 1.33E+03 0.086 0.100 0.612 1.832 MEASUREMENT ID BETWEEN END STATE
~
= ZIONSOLUTIONSuc-An Er,e,,gyS~ Company t
t t
FSS RELEASE RECORD, REV 1 PENETRATIONS SURVEY UNITS 01112, 02112 and 05120
[77]
Unit 2 Containment Penetration Measurements (continued)
H-3 (1)
Co-60 (2)
Ni-63 (1)
Sr-90 (1)
Cs-134 (2)
Cs-137 (2)
Eu-152 (2)
Eu-154 (2)
OpSOFPN OpSOFPN OpSOFB OpSOFB (pCi/m2)
(pCi/m2)
(pCi/m2)
(pCi/m2)
(pCi/m2)
(pCi/m2)
(pCi/m2)
(pCi/m2)
CTMTPN Limiting DCGL CTMT DCGL Limiting DCGL P223 Position #1 CTMT AUX Removed 9.60E+06 3.78E+05 1.67E+08 1.15E+05 8.00E+02 5.46E+06 3.52E+04 4.80E+03 0.310 0.363 2.214 6.631 P223 Position #2 CTMT AUX Removed 2.28E+06 8.97E+04 3.96E+07 2.72E+04 1.90E+02 1.30E+06 8.36E+03 1.14E+03 0.074 0.086 0.526 1.575 P223 Position #3 CTMT AUX Removed 1.96E+06 7.70E+04 3.41E+07 2.34E+04 1.63E+02 1.11E+06 7.18E+03 9.79E+02 0.063 0.074 0.452 1.353 P223 Position #4 CTMT AUX Removed 2.24E+06 8.82E+04 3.90E+07 2.67E+04 1.87E+02 1.27E+06 8.22E+03 1.12E+03 0.072 0.085 0.517 1.548 P281 Position #1 CTMT AUX Removed 1.34E+07 5.25E+05 2.32E+08 1.59E+05 1.11E+03 7.59E+06 4.90E+04 6.68E+03 0.431 0.505 3.080 9.223 P281 Position #2 CTMT AUX Removed 1.86E+06 7.31E+04 3.23E+07 2.22E+04 1.55E+02 1.06E+06 6.81E+03 9.29E+02 0.060 0.070 0.428 1.283 P281 Position #3 CTMT AUX Removed 1.27E+06 5.01E+04 2.22E+07 1.52E+04 1.06E+02 7.24E+05 4.67E+03 6.37E+02 0.041 0.048 0.294 0.880 P281 Position #4 CTMT AUX Removed 1.30E+06 5.12E+04 2.27E+07 1.55E+04 1.09E+02 7.40E+05 4.78E+03 6.51E+02 0.042 0.049 0.300 0.900 P281 Position #5 CTMT AUX Removed 1.25E+06 4.93E+04 2.18E+07 1.50E+04 1.04E+02 7.12E+05 4.60E+03 6.27E+02 0.040 0.047 0.289 0.866 P243 Position #1 CTMT AUX Removed 1.78E+07 6.98E+05 3.09E+08 2.12E+05 1.48E+03 1.01E+07 6.51E+04 8.88E+03 0.573 0.672 4.094 12.259 P243 Position #2 CTMT AUX Removed 2.07E+06 8.15E+04 3.60E+07 2.47E+04 1.73E+02 1.18E+06 7.60E+03 1.04E+03 0.067 0.078 0.478 1.430 P243 Position #3 CTMT AUX Removed 1.48E+06 5.80E+04 2.57E+07 1.76E+04 1.23E+02 8.38E+05 5.41E+03 7.38E+02 0.048 0.056 0.340 1.019 P243 Position #4 CTMT AUX Removed 1.41E+06 5.54E+04 2.45E+07 1.68E+04 1.17E+02 8.01E+05 5.17E+03 7.05E+02 0.045 0.053 0.325 0.973 P243 Position #5 CTMT AUX Removed 1.40E+06 5.51E+04 2.44E+07 1.67E+04 1.17E+02 7.96E+05 5.14E+03 7.01E+02 0.045 0.053 0.323 0.968 P303 Position #1 CTMT AUX Removed 2.07E+07 8.15E+05 3.60E+08 2.47E+05 1.73E+03 1.18E+07 7.60E+04 1.04E+04 0.668 0.783 4.776 14.303 P303 Position #2 CTMT AUX Removed 6.82E+06 2.68E+05 1.19E+08 8.14E+04 5.69E+02 3.88E+06 2.50E+04 3.41E+03 0.220 0.258 1.573 4.711 P303 Position #3 CTMT AUX Removed 9.00E+06 3.54E+05 1.56E+08 1.07E+05 7.50E+02 5.11E+06 3.30E+04 4.50E+03 0.290 0.340 2.075 6.215 P303 Position #4 CTMT AUX Removed 8.10E+06 3.18E+05 1.41E+08 9.66E+04 6.75E+02 4.60E+06 2.97E+04 4.05E+03 0.261 0.306 1.867 5.591 P303 Position #5 CTMT AUX Removed 6.82E+06 2.68E+05 1.19E+08 8.14E+04 5.69E+02 3.88E+06 2.50E+04 3.41E+03 0.220 0.258 1.573 4.711 P303 Position #6 CTMT AUX Removed 9.37E+06 3.69E+05 1.63E+08 1.12E+05 7.81E+02 5.32E+06 3.44E+04 4.69E+03 0.302 0.354 2.161 6.470 P256 Position #1 CTMT AUX Removed 1.24E+07 4.88E+05 2.16E+08 1.48E+05 1.03E+03 7.05E+06 4.55E+04 6.21E+03 0.400 0.469 2.862 8.570 P256 Position #2 CTMT AUX Removed 1.47E+06 5.79E+04 2.56E+07 1.76E+04 1.23E+02 8.36E+05 5.39E+03 7.36E+02 0.047 0.056 0.339 1.016 P256 Position #3 CTMT AUX Removed 1.18E+06 4.64E+04 2.05E+07 1.41E+04 9.83E+01 6.70E+05 4.33E+03 5.90E+02 0.038 0.045 0.272 0.814 P256 Position #4 CTMT AUX Removed 1.10E+06 4.33E+04 1.91E+07 1.31E+04 9.18E+01 6.26E+05 4.04E+03 5.51E+02 0.036 0.042 0.254 0.761 P256 Position #5 CTMT AUX Removed 1.21E+06 4.75E+04 2.10E+07 1.44E+04 1.01E+02 6.86E+05 4.43E+03 6.04E+02 0.039 0.046 0.279 0.834 P204 Position #1 CTMT AUX Removed 1.22E+07 4.79E+05 2.11E+08 1.45E+05 1.01E+03 6.91E+06 4.46E+04 6.08E+03 0.392 0.460 2.805 8.400 P204 Position #2 CTMT AUX Removed 1.84E+06 7.23E+04 3.19E+07 2.19E+04 1.53E+02 1.04E+06 6.74E+03 9.19E+02 0.059 0.069 0.424 1.269 P204 Position #3 CTMT AUX Removed 1.56E+06 6.14E+04 2.72E+07 1.86E+04 1.30E+02 8.87E+05 5.73E+03 7.81E+02 0.050 0.059 0.360 1.078 P204 Position #4 CTMT AUX Removed 1.68E+06 6.63E+04 2.93E+07 2.01E+04 1.40E+02 9.57E+05 6.18E+03 8.43E+02 0.054 0.064 0.389 1.164 P204 Position #5 CTMT AUX Removed 1.44E+06 5.67E+04 2.51E+07 1.72E+04 1.20E+02 8.20E+05 5.29E+03 7.21E+02 0.047 0.055 0.333 0.996 P242 Position #1 CTMT AUX Removed 9.91E+06 3.90E+05 1.72E+08 1.18E+05 8.26E+02 5.63E+06 3.63E+04 4.95E+03 0.320 0.375 2.285 6.842 P242 Position #2 CTMT AUX Removed 1.81E+06 7.13E+04 3.15E+07 2.16E+04 1.51E+02 1.03E+06 6.65E+03 9.06E+02 0.058 0.069 0.418 1.251 P242 Position #3 CTMT AUX Removed 1.52E+06 5.98E+04 2.64E+07 1.81E+04 1.27E+02 8.64E+05 5.58E+03 7.61E+02 0.049 0.058 0.351 1.050 P242 Position #4 CTMT AUX Removed 1.59E+06 6.27E+04 2.77E+07 1.90E+04 1.33E+02 9.06E+05 5.85E+03 7.98E+02 0.051 0.060 0.368 1.101 P242 Position #5 CTMT AUX Removed 1.55E+06 6.10E+04 2.70E+07 1.85E+04 1.29E+02 8.81E+05 5.69E+03 7.76E+02 0.050 0.059 0.358 1.071 P266 By Direct Scan CTMT AUX Removed 3.39E+05 1.33E+04 5.89E+06 4.04E+03 2.82E+01 1.92E+05 1.24E+03 1.69E+02 0.011 0.013 0.078 0.234 P269 By Direct Scan CTMT AUX Removed 7.22E+04 2.84E+03 1.25E+06 8.61E+02 6.01E+00 4.10E+04 2.65E+02 3.61E+01 0.002 0.003 0.017 0.050 P274 By Direct Scan CTMT AUX Removed 7.22E+04 2.84E+03 1.25E+06 8.61E+02 6.01E+00 4.10E+04 2.65E+02 3.61E+01 0.002 0.003 0.017 0.050 P270 By Direct Scan CTMT AUX Removed 2.78E+05 1.09E+04 4.83E+06 3.32E+03 2.32E+01 1.58E+05 1.02E+03 1.39E+02 0.009 0.011 0.064 0.192 P268 By Direct Scan CTMT AUX Removed 2.07E+05 8.13E+03 3.59E+06 2.46E+03 1.72E+01 1.17E+05 7.57E+02 1.03E+02 0.007 0.008 0.048 0.143 P222 By Direct Scan CTMT AUX Removed 6.41E+04 2.52E+03 1.11E+06 7.64E+02 5.34E+00 3.64E+04 2.35E+02 3.20E+01 0.002 0.002 0.015 0.044 P304 By Direct Scan CTMT AUX Removed 2.22E+05 8.72E+03 3.85E+06 2.64E+03 1.85E+01 1.26E+05 8.13E+02 1.11E+02 0.007 0.008 0.051 0.153 P237 Position #1 CTMT AUX Grouted 1.20E+07 4.73E+05 2.09E+08 1.43E+05 1.00E+03 6.83E+06 4.41E+04 6.01E+03 0.388 0.455 2.772 8.301 P237 Position #2 CTMT AUX Grouted 5.56E+06 2.19E+05 9.67E+07 6.63E+04 4.63E+02 3.16E+06 2.04E+04 2.78E+03 0.179 0.210 1.282 3.840 P237 Position #3 CTMT AUX Grouted 4.12E+06 1.62E+05 7.17E+07 4.92E+04 3.43E+02 2.34E+06 1.51E+04 2.06E+03 0.133 0.156 0.950 2.846 P237 Position #4 CTMT AUX Grouted 4.01E+06 1.58E+05 6.97E+07 4.78E+04 3.34E+02 2.28E+06 1.47E+04 2.00E+03 0.129 0.152 0.925 2.769 P237 Position #5 CTMT AUX Grouted 4.03E+06 1.59E+05 7.01E+07 4.81E+04 3.36E+02 2.29E+06 1.48E+04 2.02E+03 0.130 0.152 0.929 2.783 P237 Position #6 CTMT AUX Grouted 3.90E+06 1.53E+05 6.78E+07 4.65E+04 3.25E+02 2.22E+06 1.43E+04 1.95E+03 0.126 0.147 0.899 2.693 P237 Position #7 CTMT AUX Grouted 3.81E+06 1.50E+05 6.62E+07 4.54E+04 3.17E+02 2.16E+06 1.40E+04 1.90E+03 0.123 0.144 0.878 2.629 P237 Position #8 CTMT AUX Grouted 3.73E+06 1.47E+05 6.49E+07 4.45E+04 3.11E+02 2.12E+06 1.37E+04 1.87E+03 0.120 0.141 0.861 2.578 P237 Position #9 CTMT AUX Grouted 3.90E+06 1.53E+05 6.78E+07 4.66E+04 3.25E+02 2.22E+06 1.43E+04 1.95E+03 0.126 0.148 0.900 2.694 MEASUREMENT ID BETWEEN END STATE t
t t
t t
~
t t
t t
t I
I I
I I
I
+
+
t t
t t
t t
t t
+
+
~
= ZIONSOLUTIONSuc-t t
t t
t t
t t
An Er,e,,gyS~ Company
+
+
FSS RELEASE RECORD, REV 1 PENETRATIONS SURVEY UNITS 01112, 02112 and 05120
[78]
Unit 2 Containment Penetration Measurements (continued)
H-3 (1)
Co-60 (2)
Ni-63 (1)
Sr-90 (1)
Cs-134 (2)
Cs-137 (2)
Eu-152 (2)
Eu-154 (2)
OpSOFPN OpSOFPN OpSOFB OpSOFB (pCi/m2)
(pCi/m2)
(pCi/m2)
(pCi/m2)
(pCi/m2)
(pCi/m2)
(pCi/m2)
(pCi/m2)
CTMTPN Limiting DCGL CTMT DCGL Limiting DCGL P237 Position #10 CTMT AUX Grouted 3.76E+06 1.48E+05 6.54E+07 4.49E+04 3.14E+02 2.14E+06 1.38E+04 1.88E+03 0.121 0.142 0.868 2.599 P237 Position #11 CTMT AUX Grouted 3.72E+06 1.47E+05 6.48E+07 4.44E+04 3.10E+02 2.12E+06 1.37E+04 1.86E+03 0.120 0.141 0.859 2.572 P237 Position #12 CTMT AUX Grouted 3.85E+06 1.52E+05 6.70E+07 4.60E+04 3.21E+02 2.19E+06 1.41E+04 1.93E+03 0.124 0.146 0.888 2.660 P237 Position #13 CTMT AUX Grouted 3.86E+06 1.52E+05 6.71E+07 4.61E+04 3.22E+02 2.19E+06 1.42E+04 1.93E+03 0.125 0.146 0.890 2.667 P237 Position #14 CTMT AUX Grouted 3.77E+06 1.48E+05 6.56E+07 4.50E+04 3.14E+02 2.14E+06 1.38E+04 1.89E+03 0.122 0.143 0.870 2.605 P237 Position #15 CTMT AUX Grouted 3.92E+06 1.54E+05 6.81E+07 4.67E+04 3.26E+02 2.23E+06 1.44E+04 1.96E+03 0.126 0.148 0.903 2.705 P237 Position #16 CTMT AUX Grouted 3.75E+06 1.47E+05 6.52E+07 4.47E+04 3.12E+02 2.13E+06 1.37E+04 1.87E+03 0.121 0.142 0.864 2.588 P237 Position #17 CTMT AUX Grouted 3.84E+06 1.51E+05 6.68E+07 4.58E+04 3.20E+02 2.18E+06 1.41E+04 1.92E+03 0.124 0.145 0.886 2.652 P237 Position #18 CTMT AUX Grouted 4.05E+06 1.59E+05 7.04E+07 4.83E+04 3.38E+02 2.30E+06 1.49E+04 2.03E+03 0.131 0.153 0.934 2.797 P237 Position #19 CTMT AUX Grouted 3.93E+06 1.55E+05 6.84E+07 4.69E+04 3.28E+02 2.23E+06 1.44E+04 1.97E+03 0.127 0.149 0.907 2.715 P237 Position #20 CTMT AUX Grouted 3.65E+06 1.43E+05 6.34E+07 4.35E+04 3.04E+02 2.07E+06 1.34E+04 1.82E+03 0.118 0.138 0.841 2.519 P237 Position #21 CTMT AUX Grouted 3.33E+06 1.31E+05 5.78E+07 3.97E+04 2.77E+02 1.89E+06 1.22E+04 1.66E+03 0.107 0.126 0.767 2.297 P237 Position #22 CTMT AUX Grouted 3.35E+06 1.32E+05 5.82E+07 4.00E+04 2.79E+02 1.90E+06 1.23E+04 1.67E+03 0.108 0.127 0.772 2.313 P237 Position #23 CTMT AUX Grouted 3.30E+06 1.30E+05 5.73E+07 3.93E+04 2.75E+02 1.87E+06 1.21E+04 1.65E+03 0.106 0.125 0.760 2.277 P237 Position #24 CTMT AUX Grouted 3.19E+06 1.25E+05 5.54E+07 3.80E+04 2.66E+02 1.81E+06 1.17E+04 1.59E+03 0.103 0.121 0.735 2.202 P237 Position #25 CTMT AUX Grouted 3.30E+06 1.30E+05 5.75E+07 3.94E+04 2.75E+02 1.88E+06 1.21E+04 1.65E+03 0.107 0.125 0.762 2.282 P237 Position #26 CTMT AUX Grouted 3.21E+06 1.26E+05 5.58E+07 3.83E+04 2.68E+02 1.82E+06 1.18E+04 1.61E+03 0.104 0.121 0.740 2.217 P237 Position #27 CTMT AUX Grouted 3.30E+06 1.30E+05 5.73E+07 3.93E+04 2.75E+02 1.87E+06 1.21E+04 1.65E+03 0.106 0.125 0.760 2.276 P237 Position #28 CTMT AUX Grouted 3.31E+06 1.30E+05 5.75E+07 3.95E+04 2.76E+02 1.88E+06 1.21E+04 1.66E+03 0.107 0.125 0.763 2.286 P237 Position #29 CTMT AUX Grouted 3.32E+06 1.31E+05 5.78E+07 3.97E+04 2.77E+02 1.89E+06 1.22E+04 1.66E+03 0.107 0.126 0.766 2.295 P237 Position #30 CTMT AUX Grouted 3.24E+06 1.28E+05 5.64E+07 3.87E+04 2.70E+02 1.84E+06 1.19E+04 1.62E+03 0.105 0.123 0.748 2.239 P237 Position #31 CTMT AUX Grouted 3.24E+06 1.28E+05 5.64E+07 3.87E+04 2.70E+02 1.84E+06 1.19E+04 1.62E+03 0.105 0.123 0.748 2.239 P237 Position #32 CTMT AUX Grouted 3.26E+06 1.28E+05 5.67E+07 3.89E+04 2.72E+02 1.85E+06 1.20E+04 1.63E+03 0.105 0.123 0.752 2.252 P237 Position #33 CTMT AUX Grouted 3.23E+06 1.27E+05 5.61E+07 3.85E+04 2.69E+02 1.83E+06 1.18E+04 1.61E+03 0.104 0.122 0.744 2.228 P237 Position #34 CTMT AUX Grouted 3.22E+06 1.27E+05 5.60E+07 3.84E+04 2.68E+02 1.83E+06 1.18E+04 1.61E+03 0.104 0.122 0.743 2.224 P237 Position #35 CTMT AUX Grouted 3.24E+06 1.27E+05 5.63E+07 3.86E+04 2.70E+02 1.84E+06 1.19E+04 1.62E+03 0.104 0.122 0.746 2.234 P237 Position #36 CTMT AUX Grouted 3.27E+06 1.29E+05 5.69E+07 3.91E+04 2.73E+02 1.86E+06 1.20E+04 1.64E+03 0.106 0.124 0.755 2.262 P237 Position #37 CTMT AUX Grouted 3.26E+06 1.28E+05 5.67E+07 3.89E+04 2.72E+02 1.85E+06 1.20E+04 1.63E+03 0.105 0.123 0.751 2.250 P237 Position #38 CTMT AUX Grouted 3.24E+06 1.27E+05 5.63E+07 3.86E+04 2.70E+02 1.84E+06 1.19E+04 1.62E+03 0.104 0.122 0.747 2.236 P237 Position #39 CTMT AUX Grouted 3.33E+06 1.31E+05 5.79E+07 3.97E+04 2.77E+02 1.89E+06 1.22E+04 1.66E+03 0.107 0.126 0.768 2.299 P237 Position #40 CTMT AUX Grouted 3.22E+06 1.27E+05 5.60E+07 3.84E+04 2.68E+02 1.83E+06 1.18E+04 1.61E+03 0.104 0.122 0.743 2.224 P237 Position #41 CTMT AUX Grouted 3.28E+06 1.29E+05 5.71E+07 3.92E+04 2.74E+02 1.86E+06 1.20E+04 1.64E+03 0.106 0.124 0.757 2.266 P237 Position #42 CTMT AUX Grouted 3.26E+06 1.28E+05 5.67E+07 3.89E+04 2.72E+02 1.85E+06 1.20E+04 1.63E+03 0.105 0.123 0.752 2.253 P237 Position #43 CTMT AUX Grouted 3.28E+06 1.29E+05 5.70E+07 3.91E+04 2.73E+02 1.86E+06 1.20E+04 1.64E+03 0.106 0.124 0.756 2.265 P237 Position #44 CTMT AUX Grouted 3.25E+06 1.28E+05 5.64E+07 3.87E+04 2.70E+02 1.84E+06 1.19E+04 1.62E+03 0.105 0.123 0.748 2.241 P237 Position #45 CTMT AUX Grouted 3.38E+06 1.33E+05 5.87E+07 4.03E+04 2.81E+02 1.92E+06 1.24E+04 1.69E+03 0.109 0.128 0.779 2.332 P237 Position #46 CTMT AUX Grouted 3.26E+06 1.28E+05 5.67E+07 3.89E+04 2.72E+02 1.85E+06 1.20E+04 1.63E+03 0.105 0.123 0.752 2.252 P237 Position #47 CTMT AUX Grouted 3.33E+06 1.31E+05 5.79E+07 3.97E+04 2.77E+02 1.89E+06 1.22E+04 1.66E+03 0.107 0.126 0.768 2.299 P237 Position #48 CTMT AUX Grouted 3.34E+06 1.31E+05 5.81E+07 3.99E+04 2.78E+02 1.90E+06 1.22E+04 1.67E+03 0.108 0.126 0.770 2.307 P237 Position #49 CTMT AUX Grouted 3.23E+06 1.27E+05 5.62E+07 3.85E+04 2.69E+02 1.84E+06 1.18E+04 1.62E+03 0.104 0.122 0.745 2.230 P237 Position #50 CTMT AUX Grouted 3.27E+06 1.29E+05 5.69E+07 3.90E+04 2.73E+02 1.86E+06 1.20E+04 1.64E+03 0.106 0.124 0.754 2.258 P236 Position #1 CTMT AUX Grouted 1.04E+07 4.10E+05 1.81E+08 1.24E+05 8.69E+02 5.93E+06 3.83E+04 5.22E+03 0.337 0.395 2.405 7.203 P236 Position #2 CTMT AUX Grouted 5.58E+06 2.20E+05 9.71E+07 6.66E+04 4.65E+02 3.17E+06 2.05E+04 2.79E+03 0.180 0.211 1.287 3.855 P236 Position #3 CTMT AUX Grouted 4.00E+06 1.57E+05 6.96E+07 4.78E+04 3.34E+02 2.27E+06 1.47E+04 2.00E+03 0.129 0.151 0.923 2.765 P236 Position #4 CTMT AUX Grouted 3.96E+06 1.56E+05 6.89E+07 4.73E+04 3.30E+02 2.25E+06 1.45E+04 1.98E+03 0.128 0.150 0.914 2.738 P236 Position #5 CTMT AUX Grouted 3.93E+06 1.55E+05 6.84E+07 4.69E+04 3.28E+02 2.24E+06 1.44E+04 1.97E+03 0.127 0.149 0.907 2.717 P236 Position #6 CTMT AUX Grouted 3.82E+06 1.50E+05 6.65E+07 4.56E+04 3.19E+02 2.17E+06 1.40E+04 1.91E+03 0.123 0.145 0.882 2.641 P236 Position #7 CTMT AUX Grouted 3.65E+06 1.44E+05 6.35E+07 4.36E+04 3.04E+02 2.08E+06 1.34E+04 1.83E+03 0.118 0.138 0.842 2.522 P236 Position #8 CTMT AUX Grouted 3.63E+06 1.43E+05 6.32E+07 4.34E+04 3.03E+02 2.06E+06 1.33E+04 1.82E+03 0.117 0.137 0.838 2.510 P236 Position #9 CTMT AUX Grouted 3.58E+06 1.41E+05 6.22E+07 4.27E+04 2.98E+02 2.03E+06 1.31E+04 1.79E+03 0.116 0.135 0.826 2.472 P236 Position #10 CTMT AUX Grouted 3.62E+06 1.43E+05 6.30E+07 4.32E+04 3.02E+02 2.06E+06 1.33E+04 1.81E+03 0.117 0.137 0.836 2.503 MEASUREMENT ID BETWEEN END STATE
~
=ZIONSOLUTIONSuc-An Er,e,,gyS~ Company
FSS RELEASE RECORD, REV 1 PENETRATIONS SURVEY UNITS 01112, 02112 and 05120
[79]
Unit 2 Containment Penetration Measurements (continued)
H-3 (1)
Co-60 (2)
Ni-63 (1)
Sr-90 (1)
Cs-134 (2)
Cs-137 (2)
Eu-152 (2)
Eu-154 (2)
OpSOFPN OpSOFPN OpSOFB OpSOFB (pCi/m2)
(pCi/m2)
(pCi/m2)
(pCi/m2)
(pCi/m2)
(pCi/m2)
(pCi/m2)
(pCi/m2)
CTMTPN Limiting DCGL CTMT DCGL Limiting DCGL P236 Position #11 CTMT AUX Grouted 3.51E+06 1.38E+05 6.10E+07 4.19E+04 2.92E+02 1.99E+06 1.29E+04 1.75E+03 0.113 0.133 0.809 2.423 P236 Position #12 CTMT AUX Grouted 3.59E+06 1.41E+05 6.24E+07 4.28E+04 2.99E+02 2.04E+06 1.32E+04 1.80E+03 0.116 0.136 0.828 2.479 P236 Position #13 CTMT AUX Grouted 3.62E+06 1.43E+05 6.30E+07 4.32E+04 3.02E+02 2.06E+06 1.33E+04 1.81E+03 0.117 0.137 0.836 2.502 P236 Position #14 CTMT AUX Grouted 3.56E+06 1.40E+05 6.19E+07 4.25E+04 2.97E+02 2.02E+06 1.30E+04 1.78E+03 0.115 0.135 0.821 2.457 P236 Position #15 CTMT AUX Grouted 3.58E+06 1.41E+05 6.22E+07 4.27E+04 2.98E+02 2.03E+06 1.31E+04 1.79E+03 0.115 0.135 0.825 2.472 P236 Position #16 CTMT AUX Grouted 3.61E+06 1.42E+05 6.28E+07 4.31E+04 3.01E+02 2.05E+06 1.32E+04 1.81E+03 0.117 0.137 0.833 2.495 P236 Position #17 CTMT AUX Grouted 3.63E+06 1.43E+05 6.32E+07 4.33E+04 3.03E+02 2.06E+06 1.33E+04 1.82E+03 0.117 0.137 0.838 2.508 P236 Position #18 CTMT AUX Grouted 3.66E+06 1.44E+05 6.37E+07 4.37E+04 3.05E+02 2.08E+06 1.34E+04 1.83E+03 0.118 0.139 0.845 2.530 P236 Position #19 CTMT AUX Grouted 3.65E+06 1.44E+05 6.35E+07 4.36E+04 3.05E+02 2.08E+06 1.34E+04 1.83E+03 0.118 0.138 0.843 2.523 P236 Position #20 CTMT AUX Grouted 3.47E+06 1.36E+05 6.03E+07 4.14E+04 2.89E+02 1.97E+06 1.27E+04 1.73E+03 0.112 0.131 0.799 2.394 P236 Position #21 CTMT AUX Grouted 3.38E+06 1.33E+05 5.89E+07 4.04E+04 2.82E+02 1.92E+06 1.24E+04 1.69E+03 0.109 0.128 0.781 2.338 P236 Position #22 CTMT AUX Grouted 3.33E+06 1.31E+05 5.79E+07 3.97E+04 2.77E+02 1.89E+06 1.22E+04 1.66E+03 0.107 0.126 0.768 2.299 P236 Position #23 CTMT AUX Grouted 3.20E+06 1.26E+05 5.57E+07 3.82E+04 2.67E+02 1.82E+06 1.17E+04 1.60E+03 0.103 0.121 0.738 2.211 P236 Position #24 CTMT AUX Grouted 3.12E+06 1.23E+05 5.42E+07 3.72E+04 2.60E+02 1.77E+06 1.14E+04 1.56E+03 0.101 0.118 0.719 2.154 P236 Position #25 CTMT AUX Grouted 3.18E+06 1.25E+05 5.52E+07 3.79E+04 2.65E+02 1.80E+06 1.16E+04 1.59E+03 0.103 0.120 0.733 2.194 P236 Position #26 CTMT AUX Grouted 3.19E+06 1.25E+05 5.54E+07 3.80E+04 2.66E+02 1.81E+06 1.17E+04 1.59E+03 0.103 0.121 0.735 2.201 P236 Position #27 CTMT AUX Grouted 3.28E+06 1.29E+05 5.70E+07 3.91E+04 2.73E+02 1.86E+06 1.20E+04 1.64E+03 0.106 0.124 0.756 2.264 P236 Position #28 CTMT AUX Grouted 3.33E+06 1.31E+05 5.78E+07 3.97E+04 2.77E+02 1.89E+06 1.22E+04 1.66E+03 0.107 0.126 0.767 2.298 P236 Position #29 CTMT AUX Grouted 3.24E+06 1.28E+05 5.64E+07 3.87E+04 2.70E+02 1.84E+06 1.19E+04 1.62E+03 0.105 0.123 0.748 2.239 P236 Position #30 CTMT AUX Grouted 3.25E+06 1.28E+05 5.65E+07 3.88E+04 2.71E+02 1.85E+06 1.19E+04 1.63E+03 0.105 0.123 0.750 2.245 P236 Position #31 CTMT AUX Grouted 3.31E+06 1.30E+05 5.75E+07 3.94E+04 2.75E+02 1.88E+06 1.21E+04 1.65E+03 0.107 0.125 0.762 2.282 P236 Position #32 CTMT AUX Grouted 3.30E+06 1.30E+05 5.73E+07 3.93E+04 2.75E+02 1.87E+06 1.21E+04 1.65E+03 0.106 0.125 0.760 2.277 P236 Position #33 CTMT AUX Grouted 3.15E+06 1.24E+05 5.48E+07 3.76E+04 2.63E+02 1.79E+06 1.16E+04 1.58E+03 0.102 0.119 0.727 2.176 P236 Position #34 CTMT AUX Grouted 3.28E+06 1.29E+05 5.71E+07 3.92E+04 2.74E+02 1.87E+06 1.20E+04 1.64E+03 0.106 0.124 0.757 2.267 P236 Position #35 CTMT AUX Grouted 3.29E+06 1.29E+05 5.72E+07 3.92E+04 2.74E+02 1.87E+06 1.21E+04 1.64E+03 0.106 0.124 0.758 2.270 P236 Position #36 CTMT AUX Grouted 3.20E+06 1.26E+05 5.56E+07 3.81E+04 2.66E+02 1.82E+06 1.17E+04 1.60E+03 0.103 0.121 0.737 2.207 P236 Position #37 CTMT AUX Grouted 3.35E+06 1.32E+05 5.83E+07 4.00E+04 2.79E+02 1.90E+06 1.23E+04 1.68E+03 0.108 0.127 0.773 2.315 P236 Position #38 CTMT AUX Grouted 3.24E+06 1.28E+05 5.64E+07 3.87E+04 2.70E+02 1.84E+06 1.19E+04 1.62E+03 0.105 0.123 0.748 2.241 P236 Position #39 CTMT AUX Grouted 3.35E+06 1.32E+05 5.82E+07 3.99E+04 2.79E+02 1.90E+06 1.23E+04 1.67E+03 0.108 0.127 0.772 2.311 P236 Position #40 CTMT AUX Grouted 3.40E+06 1.34E+05 5.92E+07 4.06E+04 2.84E+02 1.93E+06 1.25E+04 1.70E+03 0.110 0.129 0.785 2.350 P236 Position #41 CTMT AUX Grouted 3.36E+06 1.32E+05 5.84E+07 4.01E+04 2.80E+02 1.91E+06 1.23E+04 1.68E+03 0.108 0.127 0.775 2.321 P236 Position #42 CTMT AUX Grouted 3.29E+06 1.30E+05 5.73E+07 3.93E+04 2.74E+02 1.87E+06 1.21E+04 1.65E+03 0.106 0.125 0.759 2.274 P236 Position #43 CTMT AUX Grouted 3.34E+06 1.32E+05 5.81E+07 3.99E+04 2.79E+02 1.90E+06 1.23E+04 1.67E+03 0.108 0.127 0.771 2.309 P236 Position #44 CTMT AUX Grouted 3.33E+06 1.31E+05 5.80E+07 3.98E+04 2.78E+02 1.89E+06 1.22E+04 1.67E+03 0.108 0.126 0.769 2.303 P236 Position #45 CTMT AUX Grouted 3.30E+06 1.30E+05 5.74E+07 3.94E+04 2.75E+02 1.88E+06 1.21E+04 1.65E+03 0.106 0.125 0.761 2.279 P236 Position #46 CTMT AUX Grouted 3.39E+06 1.34E+05 5.90E+07 4.05E+04 2.83E+02 1.93E+06 1.24E+04 1.70E+03 0.110 0.128 0.783 2.344 P236 Position #47 CTMT AUX Grouted 3.41E+06 1.34E+05 5.94E+07 4.07E+04 2.85E+02 1.94E+06 1.25E+04 1.71E+03 0.110 0.129 0.787 2.358 P236 Position #48 CTMT AUX Grouted 3.42E+06 1.35E+05 5.96E+07 4.09E+04 2.85E+02 1.95E+06 1.26E+04 1.71E+03 0.111 0.130 0.790 2.365 P236 Position #49 CTMT AUX Grouted 3.33E+06 1.31E+05 5.80E+07 3.98E+04 2.78E+02 1.89E+06 1.22E+04 1.67E+03 0.108 0.126 0.769 2.302 P236 Position #50 CTMT AUX Grouted 3.48E+06 1.37E+05 6.05E+07 4.15E+04 2.90E+02 1.98E+06 1.28E+04 1.74E+03 0.112 0.132 0.803 2.404 P235 Position #1 CTMT AUX Grouted 9.25E+06 3.64E+05 1.61E+08 1.10E+05 7.71E+02 5.25E+06 3.39E+04 4.62E+03 0.298 0.350 2.133 6.387 P235 Position #2 CTMT AUX Grouted 4.94E+06 1.94E+05 8.59E+07 5.90E+04 4.12E+02 2.81E+06 1.81E+04 2.47E+03 0.159 0.187 1.140 3.413 P235 Position #3 CTMT AUX Grouted 3.96E+06 1.56E+05 6.89E+07 4.73E+04 3.30E+02 2.25E+06 1.45E+04 1.98E+03 0.128 0.150 0.914 2.736 P235 Position #4 CTMT AUX Grouted 4.01E+06 1.58E+05 6.97E+07 4.78E+04 3.34E+02 2.28E+06 1.47E+04 2.00E+03 0.129 0.152 0.924 2.767 P235 Position #5 CTMT AUX Grouted 3.96E+06 1.56E+05 6.89E+07 4.73E+04 3.30E+02 2.25E+06 1.45E+04 1.98E+03 0.128 0.150 0.914 2.737 P235 Position #6 CTMT AUX Grouted 3.99E+06 1.57E+05 6.94E+07 4.76E+04 3.32E+02 2.27E+06 1.46E+04 1.99E+03 0.129 0.151 0.920 2.754 P235 Position #7 CTMT AUX Grouted 3.91E+06 1.54E+05 6.80E+07 4.67E+04 3.26E+02 2.22E+06 1.43E+04 1.96E+03 0.126 0.148 0.902 2.701 P235 Position #8 CTMT AUX Grouted 3.95E+06 1.55E+05 6.87E+07 4.71E+04 3.29E+02 2.24E+06 1.45E+04 1.97E+03 0.127 0.149 0.911 2.727 P235 Position #9 CTMT AUX Grouted 4.01E+06 1.58E+05 6.97E+07 4.78E+04 3.34E+02 2.28E+06 1.47E+04 2.00E+03 0.129 0.152 0.925 2.769 P235 Position #10 CTMT AUX Grouted 4.00E+06 1.57E+05 6.95E+07 4.77E+04 3.33E+02 2.27E+06 1.47E+04 2.00E+03 0.129 0.151 0.922 2.760 P235 Position #11 CTMT AUX Grouted 3.88E+06 1.53E+05 6.75E+07 4.63E+04 3.24E+02 2.21E+06 1.42E+04 1.94E+03 0.125 0.147 0.896 2.682 MEASUREMENT ID BETWEEN END STATE
~
=ZIONSOLUTIONSuc-An Er,e,,gyS~ Company
FSS RELEASE RECORD, REV 1 PENETRATIONS SURVEY UNITS 01112, 02112 and 05120
[80]
Unit 2 Containment Penetration Measurements (continued)
H-3 (1)
Co-60 (2)
Ni-63 (1)
Sr-90 (1)
Cs-134 (2)
Cs-137 (2)
Eu-152 (2)
Eu-154 (2)
OpSOFPN OpSOFPN OpSOFB OpSOFB (pCi/m2)
(pCi/m2)
(pCi/m2)
(pCi/m2)
(pCi/m2)
(pCi/m2)
(pCi/m2)
(pCi/m2)
CTMTPN Limiting DCGL CTMT DCGL Limiting DCGL P235 Position #12 CTMT AUX Grouted 3.89E+06 1.53E+05 6.77E+07 4.65E+04 3.24E+02 2.21E+06 1.43E+04 1.95E+03 0.126 0.147 0.898 2.689 P235 Position #13 CTMT AUX Grouted 3.87E+06 1.52E+05 6.73E+07 4.62E+04 3.23E+02 2.20E+06 1.42E+04 1.94E+03 0.125 0.146 0.892 2.672 P235 Position #14 CTMT AUX Grouted 3.87E+06 1.52E+05 6.73E+07 4.62E+04 3.22E+02 2.20E+06 1.42E+04 1.93E+03 0.125 0.146 0.892 2.671 P235 Position #15 CTMT AUX Grouted 3.85E+06 1.51E+05 6.69E+07 4.59E+04 3.20E+02 2.18E+06 1.41E+04 1.92E+03 0.124 0.145 0.887 2.656 P235 Position #16 CTMT AUX Grouted 3.78E+06 1.49E+05 6.57E+07 4.51E+04 3.15E+02 2.15E+06 1.39E+04 1.89E+03 0.122 0.143 0.872 2.610 P235 Position #17 CTMT AUX Grouted 3.82E+06 1.50E+05 6.64E+07 4.56E+04 3.18E+02 2.17E+06 1.40E+04 1.91E+03 0.123 0.144 0.880 2.637 P235 Position #18 CTMT AUX Grouted 3.77E+06 1.48E+05 6.56E+07 4.50E+04 3.15E+02 2.14E+06 1.38E+04 1.89E+03 0.122 0.143 0.870 2.607 P235 Position #19 CTMT AUX Grouted 3.70E+06 1.45E+05 6.43E+07 4.41E+04 3.08E+02 2.10E+06 1.36E+04 1.85E+03 0.119 0.140 0.853 2.553 P235 Position #20 CTMT AUX Grouted 3.53E+06 1.39E+05 6.13E+07 4.21E+04 2.94E+02 2.00E+06 1.29E+04 1.76E+03 0.114 0.133 0.814 2.437 P235 Position #21 CTMT AUX Grouted 3.45E+06 1.36E+05 5.99E+07 4.11E+04 2.87E+02 1.96E+06 1.26E+04 1.72E+03 0.111 0.130 0.795 2.380 P235 Position #22 CTMT AUX Grouted 3.37E+06 1.33E+05 5.86E+07 4.02E+04 2.81E+02 1.92E+06 1.24E+04 1.69E+03 0.109 0.128 0.778 2.329 P235 Position #23 CTMT AUX Grouted 3.32E+06 1.31E+05 5.77E+07 3.96E+04 2.77E+02 1.89E+06 1.22E+04 1.66E+03 0.107 0.126 0.765 2.292 P235 Position #24 CTMT AUX Grouted 3.23E+06 1.27E+05 5.62E+07 3.85E+04 2.69E+02 1.83E+06 1.18E+04 1.61E+03 0.104 0.122 0.745 2.230 P235 Position #25 CTMT AUX Grouted 3.26E+06 1.28E+05 5.67E+07 3.89E+04 2.72E+02 1.85E+06 1.20E+04 1.63E+03 0.105 0.123 0.752 2.253 P235 Position #26 CTMT AUX Grouted 3.26E+06 1.28E+05 5.67E+07 3.89E+04 2.72E+02 1.85E+06 1.20E+04 1.63E+03 0.105 0.123 0.753 2.254 P235 Position #27 CTMT AUX Grouted 3.39E+06 1.33E+05 5.89E+07 4.04E+04 2.82E+02 1.92E+06 1.24E+04 1.69E+03 0.109 0.128 0.781 2.339 P235 Position #28 CTMT AUX Grouted 3.30E+06 1.30E+05 5.74E+07 3.94E+04 2.75E+02 1.87E+06 1.21E+04 1.65E+03 0.106 0.125 0.761 2.279 P235 Position #29 CTMT AUX Grouted 3.38E+06 1.33E+05 5.88E+07 4.04E+04 2.82E+02 1.92E+06 1.24E+04 1.69E+03 0.109 0.128 0.780 2.337 P235 Position #30 CTMT AUX Grouted 3.33E+06 1.31E+05 5.78E+07 3.97E+04 2.77E+02 1.89E+06 1.22E+04 1.66E+03 0.107 0.126 0.767 2.297 P235 Position #31 CTMT AUX Grouted 3.31E+06 1.30E+05 5.75E+07 3.94E+04 2.75E+02 1.88E+06 1.21E+04 1.65E+03 0.107 0.125 0.762 2.282 P235 Position #32 CTMT AUX Grouted 3.31E+06 1.30E+05 5.76E+07 3.95E+04 2.76E+02 1.88E+06 1.22E+04 1.66E+03 0.107 0.125 0.764 2.289 P235 Position #33 CTMT AUX Grouted 3.25E+06 1.28E+05 5.66E+07 3.88E+04 2.71E+02 1.85E+06 1.19E+04 1.63E+03 0.105 0.123 0.750 2.246 P235 Position #34 CTMT AUX Grouted 3.27E+06 1.29E+05 5.68E+07 3.90E+04 2.72E+02 1.86E+06 1.20E+04 1.63E+03 0.105 0.124 0.754 2.258 P235 Position #35 CTMT AUX Grouted 3.27E+06 1.29E+05 5.69E+07 3.91E+04 2.73E+02 1.86E+06 1.20E+04 1.64E+03 0.106 0.124 0.755 2.261 P235 Position #36 CTMT AUX Grouted 3.31E+06 1.30E+05 5.76E+07 3.95E+04 2.76E+02 1.88E+06 1.21E+04 1.66E+03 0.107 0.125 0.764 2.287 P235 Position #37 CTMT AUX Grouted 3.28E+06 1.29E+05 5.70E+07 3.91E+04 2.73E+02 1.86E+06 1.20E+04 1.64E+03 0.106 0.124 0.756 2.264 P235 Position #38 CTMT AUX Grouted 3.38E+06 1.33E+05 5.87E+07 4.03E+04 2.82E+02 1.92E+06 1.24E+04 1.69E+03 0.109 0.128 0.779 2.333 P235 Position #39 CTMT AUX Grouted 3.33E+06 1.31E+05 5.79E+07 3.98E+04 2.78E+02 1.89E+06 1.22E+04 1.67E+03 0.108 0.126 0.768 2.301 P235 Position #40 CTMT AUX Grouted 3.28E+06 1.29E+05 5.70E+07 3.91E+04 2.73E+02 1.86E+06 1.20E+04 1.64E+03 0.106 0.124 0.756 2.264 P235 Position #41 CTMT AUX Grouted 3.28E+06 1.29E+05 5.71E+07 3.92E+04 2.74E+02 1.87E+06 1.20E+04 1.64E+03 0.106 0.124 0.757 2.267 P235 Position #42 CTMT AUX Grouted 3.36E+06 1.32E+05 5.84E+07 4.01E+04 2.80E+02 1.91E+06 1.23E+04 1.68E+03 0.108 0.127 0.775 2.321 P235 Position #43 CTMT AUX Grouted 3.38E+06 1.33E+05 5.87E+07 4.03E+04 2.82E+02 1.92E+06 1.24E+04 1.69E+03 0.109 0.128 0.779 2.333 P235 Position #44 CTMT AUX Grouted 3.36E+06 1.32E+05 5.84E+07 4.01E+04 2.80E+02 1.91E+06 1.23E+04 1.68E+03 0.108 0.127 0.775 2.321 P235 Position #45 CTMT AUX Grouted 3.38E+06 1.33E+05 5.88E+07 4.03E+04 2.82E+02 1.92E+06 1.24E+04 1.69E+03 0.109 0.128 0.779 2.334 P235 Position #46 CTMT AUX Grouted 3.52E+06 1.38E+05 6.12E+07 4.20E+04 2.93E+02 2.00E+06 1.29E+04 1.76E+03 0.114 0.133 0.812 2.431 P235 Position #47 CTMT AUX Grouted 3.50E+06 1.38E+05 6.08E+07 4.17E+04 2.91E+02 1.99E+06 1.28E+04 1.75E+03 0.113 0.132 0.807 2.415 P235 Position #48 CTMT AUX Grouted 3.43E+06 1.35E+05 5.97E+07 4.10E+04 2.86E+02 1.95E+06 1.26E+04 1.72E+03 0.111 0.130 0.792 2.371 P235 Position #49 CTMT AUX Grouted 3.43E+06 1.35E+05 5.96E+07 4.09E+04 2.86E+02 1.95E+06 1.26E+04 1.71E+03 0.111 0.130 0.790 2.367 P235 Position #50 CTMT AUX Grouted 3.62E+06 1.42E+05 6.30E+07 4.32E+04 3.02E+02 2.06E+06 1.33E+04 1.81E+03 0.117 0.137 0.835 2.501 P323 Position #1 CTMT AUX Grouted 1.40E+07 5.50E+05 2.43E+08 1.67E+05 1.16E+03 7.94E+06 5.12E+04 6.99E+03 0.451 0.529 3.222 9.649 P323 Position #2 CTMT AUX Grouted 1.81E+07 7.12E+05 3.15E+08 2.16E+05 1.51E+03 1.03E+07 6.64E+04 9.06E+03 0.584 0.685 4.176 12.506 P323 Position #3 CTMT AUX Grouted 6.56E+06 2.58E+05 1.14E+08 7.82E+04 5.47E+02 3.73E+06 2.40E+04 3.28E+03 0.212 0.248 1.512 4.528 P323 Position #4 CTMT AUX Grouted 5.02E+06 1.98E+05 8.73E+07 5.99E+04 4.19E+02 2.85E+06 1.84E+04 2.51E+03 0.162 0.190 1.158 3.468 P323 Position #5 CTMT AUX Grouted 5.22E+06 2.05E+05 9.07E+07 6.22E+04 4.35E+02 2.96E+06 1.91E+04 2.61E+03 0.168 0.197 1.203 3.602 P323 Position #6 CTMT AUX Grouted 6.08E+06 2.39E+05 1.06E+08 7.26E+04 5.07E+02 3.46E+06 2.23E+04 3.04E+03 0.196 0.230 1.403 4.201 P323 Position #7 CTMT AUX Grouted 6.12E+06 2.41E+05 1.06E+08 7.30E+04 5.10E+02 3.47E+06 2.24E+04 3.06E+03 0.197 0.231 1.410 4.223 P323 Position #8 CTMT AUX Grouted 6.28E+06 2.47E+05 1.09E+08 7.49E+04 5.23E+02 3.57E+06 2.30E+04 3.14E+03 0.203 0.237 1.447 4.334 P323 Position #9 CTMT AUX Grouted 7.77E+06 3.06E+05 1.35E+08 9.27E+04 6.48E+02 4.42E+06 2.85E+04 3.89E+03 0.251 0.294 1.792 5.367 P323 Position #10 CTMT AUX Grouted 7.51E+06 2.95E+05 1.31E+08 8.96E+04 6.26E+02 4.27E+06 2.75E+04 3.75E+03 0.242 0.284 1.731 5.184 P323 Position #11 CTMT AUX Grouted 5.41E+06 2.13E+05 9.41E+07 6.46E+04 4.51E+02 3.08E+06 1.98E+04 2.71E+03 0.175 0.205 1.248 3.738 P323 Position #12 CTMT AUX Grouted 4.81E+06 1.89E+05 8.37E+07 5.74E+04 4.01E+02 2.73E+06 1.76E+04 2.41E+03 0.155 0.182 1.110 3.323 MEASUREMENT ID BETWEEN END STATE
~
=ZIONSOLUTIONSuc-An Er,e,,gyS~ Company
FSS RELEASE RECORD, REV 1 PENETRATIONS SURVEY UNITS 01112, 02112 and 05120
[81]
Unit 2 Containment Penetration Measurements (continued)
H-3 (1)
Co-60 (2)
Ni-63 (1)
Sr-90 (1)
Cs-134 (2)
Cs-137 (2)
Eu-152 (2)
Eu-154 (2)
OpSOFPN OpSOFPN OpSOFB OpSOFB (pCi/m2)
(pCi/m2)
(pCi/m2)
(pCi/m2)
(pCi/m2)
(pCi/m2)
(pCi/m2)
(pCi/m2)
CTMTPN Limiting DCGL CTMT DCGL Limiting DCGL P323 Position #13 CTMT AUX Grouted 4.64E+06 1.83E+05 8.07E+07 5.54E+04 3.87E+02 2.64E+06 1.70E+04 2.32E+03 0.150 0.176 1.071 3.206 P323 Position #14 CTMT AUX Grouted 4.49E+06 1.77E+05 7.80E+07 5.36E+04 3.74E+02 2.55E+06 1.65E+04 2.24E+03 0.145 0.170 1.035 3.100 P323 Position #15 CTMT AUX Grouted 4.53E+06 1.78E+05 7.87E+07 5.40E+04 3.77E+02 2.57E+06 1.66E+04 2.26E+03 0.146 0.171 1.044 3.127 P323 Position #16 CTMT AUX Grouted 4.59E+06 1.80E+05 7.98E+07 5.47E+04 3.82E+02 2.61E+06 1.68E+04 2.29E+03 0.148 0.174 1.058 3.168 P323 Position #17 CTMT AUX Grouted 5.38E+06 2.11E+05 9.35E+07 6.41E+04 4.48E+02 3.05E+06 1.97E+04 2.69E+03 0.173 0.203 1.240 3.713 P323 Position #18 CTMT AUX Grouted 7.88E+06 3.10E+05 1.37E+08 9.40E+04 6.57E+02 4.48E+06 2.89E+04 3.94E+03 0.254 0.298 1.818 5.443 P323 Position #19 CTMT AUX Grouted 6.04E+06 2.38E+05 1.05E+08 7.20E+04 5.03E+02 3.43E+06 2.21E+04 3.02E+03 0.195 0.228 1.392 4.170 P323 Position #20 CTMT AUX Grouted 4.95E+06 1.95E+05 8.60E+07 5.90E+04 4.12E+02 2.81E+06 1.81E+04 2.47E+03 0.160 0.187 1.141 3.417 P323 Position #21 CTMT AUX Grouted 4.58E+06 1.80E+05 7.96E+07 5.46E+04 3.82E+02 2.60E+06 1.68E+04 2.29E+03 0.148 0.173 1.056 3.163 P323 Position #22 CTMT AUX Grouted 4.07E+06 1.60E+05 7.07E+07 4.85E+04 3.39E+02 2.31E+06 1.49E+04 2.03E+03 0.131 0.154 0.938 2.810 P323 Position #23 CTMT AUX Grouted 4.02E+06 1.58E+05 6.99E+07 4.80E+04 3.35E+02 2.28E+06 1.47E+04 2.01E+03 0.130 0.152 0.927 2.776 P323 Position #24 CTMT AUX Grouted 3.87E+06 1.52E+05 6.73E+07 4.62E+04 3.23E+02 2.20E+06 1.42E+04 1.94E+03 0.125 0.146 0.893 2.674 P323 Position #25 CTMT AUX Grouted 3.76E+06 1.48E+05 6.54E+07 4.49E+04 3.13E+02 2.14E+06 1.38E+04 1.88E+03 0.121 0.142 0.867 2.598 P323 Position #26 CTMT AUX Grouted 4.11E+06 1.62E+05 7.15E+07 4.90E+04 3.43E+02 2.34E+06 1.51E+04 2.06E+03 0.133 0.155 0.948 2.839 P323 Position #27 CTMT AUX Grouted 5.31E+06 2.09E+05 9.24E+07 6.34E+04 4.43E+02 3.02E+06 1.95E+04 2.66E+03 0.171 0.201 1.225 3.668 P323 Position #28 CTMT AUX Grouted 4.62E+06 1.82E+05 8.03E+07 5.51E+04 3.85E+02 2.62E+06 1.69E+04 2.31E+03 0.149 0.175 1.065 3.189 P323 Position #29 CTMT AUX Grouted 4.59E+06 1.81E+05 7.98E+07 5.48E+04 3.83E+02 2.61E+06 1.68E+04 2.30E+03 0.148 0.174 1.058 3.170 P323 Position #30 CTMT AUX Grouted 4.00E+06 1.57E+05 6.96E+07 4.77E+04 3.34E+02 2.27E+06 1.47E+04 2.00E+03 0.129 0.151 0.923 2.763 P323 Position #31 CTMT AUX Grouted 3.78E+06 1.49E+05 6.57E+07 4.51E+04 3.15E+02 2.15E+06 1.39E+04 1.89E+03 0.122 0.143 0.872 2.611 P323 Position #32 CTMT AUX Grouted 3.79E+06 1.49E+05 6.58E+07 4.52E+04 3.16E+02 2.15E+06 1.39E+04 1.89E+03 0.122 0.143 0.873 2.615 P323 Position #33 CTMT AUX Grouted 3.79E+06 1.49E+05 6.59E+07 4.52E+04 3.16E+02 2.15E+06 1.39E+04 1.90E+03 0.122 0.143 0.874 2.617 P323 Position #34 CTMT AUX Grouted 3.80E+06 1.50E+05 6.61E+07 4.54E+04 3.17E+02 2.16E+06 1.39E+04 1.90E+03 0.123 0.144 0.877 2.625 P323 Position #35 CTMT AUX Grouted 4.15E+06 1.63E+05 7.21E+07 4.95E+04 3.46E+02 2.36E+06 1.52E+04 2.07E+03 0.134 0.157 0.956 2.864 P323 Position #36 CTMT AUX Grouted 5.16E+06 2.03E+05 8.98E+07 6.16E+04 4.30E+02 2.93E+06 1.89E+04 2.58E+03 0.167 0.195 1.191 3.566 P323 Position #37 CTMT AUX Grouted 4.33E+06 1.70E+05 7.52E+07 5.16E+04 3.61E+02 2.46E+06 1.59E+04 2.16E+03 0.140 0.164 0.998 2.988 P323 Position #38 CTMT AUX Grouted 4.18E+06 1.65E+05 7.27E+07 4.99E+04 3.49E+02 2.38E+06 1.53E+04 2.09E+03 0.135 0.158 0.965 2.889 P323 Position #39 CTMT AUX Grouted 3.98E+06 1.57E+05 6.92E+07 4.75E+04 3.32E+02 2.26E+06 1.46E+04 1.99E+03 0.128 0.150 0.917 2.747 P323 Position #40 CTMT AUX Grouted 3.99E+06 1.57E+05 6.94E+07 4.76E+04 3.33E+02 2.27E+06 1.46E+04 2.00E+03 0.129 0.151 0.921 2.757 P323 Position #41 CTMT AUX Grouted 4.09E+06 1.61E+05 7.10E+07 4.87E+04 3.41E+02 2.32E+06 1.50E+04 2.04E+03 0.132 0.155 0.942 2.821 P323 Position #42 CTMT AUX Grouted 4.09E+06 1.61E+05 7.10E+07 4.87E+04 3.41E+02 2.32E+06 1.50E+04 2.04E+03 0.132 0.155 0.942 2.821 P323 Position #43 CTMT AUX Grouted 4.14E+06 1.63E+05 7.19E+07 4.93E+04 3.45E+02 2.35E+06 1.52E+04 2.07E+03 0.133 0.156 0.954 2.856 P323 Position #44 CTMT AUX Grouted 4.27E+06 1.68E+05 7.43E+07 5.10E+04 3.56E+02 2.43E+06 1.57E+04 2.14E+03 0.138 0.162 0.985 2.951 P323 Position #45 CTMT AUX Grouted 4.53E+06 1.78E+05 7.88E+07 5.41E+04 3.78E+02 2.57E+06 1.66E+04 2.27E+03 0.146 0.171 1.045 3.128 P323 Position #46 CTMT AUX Grouted 6.59E+06 2.59E+05 1.15E+08 7.87E+04 5.50E+02 3.75E+06 2.42E+04 3.30E+03 0.213 0.249 1.521 4.554 P323 Position #47 CTMT AUX Grouted 6.41E+06 2.52E+05 1.11E+08 7.64E+04 5.34E+02 3.64E+06 2.35E+04 3.20E+03 0.207 0.242 1.477 4.425 P323 Position #48 CTMT AUX Grouted 5.33E+06 2.10E+05 9.27E+07 6.36E+04 4.44E+02 3.03E+06 1.95E+04 2.67E+03 0.172 0.202 1.229 3.680 P323 Position #49 CTMT AUX Grouted 5.09E+06 2.00E+05 8.84E+07 6.07E+04 4.24E+02 2.89E+06 1.87E+04 2.54E+03 0.164 0.192 1.173 3.513 P323 Position #50 CTMT AUX Grouted 5.58E+06 2.20E+05 9.71E+07 6.66E+04 4.65E+02 3.17E+06 2.05E+04 2.79E+03 0.180 0.211 1.287 3.855 P323 Position #1 CTMT AUX Grouted 4.43E+06 1.74E+05 7.70E+07 5.28E+04 3.69E+02 2.52E+06 1.62E+04 2.21E+03 0.143 0.167 1.021 3.058 P324 Position #1 CTMT AUX Grouted 1.17E+07 4.62E+05 2.04E+08 1.40E+05 9.78E+02 6.67E+06 4.30E+04 5.87E+03 0.379 0.444 2.707 8.106 P324 Position #2 CTMT AUX Grouted 5.31E+06 2.09E+05 9.24E+07 6.34E+04 4.43E+02 3.02E+06 1.95E+04 2.66E+03 0.171 0.201 1.225 3.668 P324 Position #3 CTMT AUX Grouted 4.22E+06 1.66E+05 7.33E+07 5.03E+04 3.51E+02 2.40E+06 1.55E+04 2.11E+03 0.136 0.159 0.972 2.911 P324 Position #4 CTMT AUX Grouted 4.34E+06 1.71E+05 7.54E+07 5.18E+04 3.62E+02 2.47E+06 1.59E+04 2.17E+03 0.140 0.164 1.001 2.996 P324 Position #5 CTMT AUX Grouted 4.30E+06 1.69E+05 7.47E+07 5.13E+04 3.58E+02 2.44E+06 1.58E+04 2.15E+03 0.139 0.163 0.991 2.967 P324 Position #6 CTMT AUX Grouted 4.13E+06 1.62E+05 7.18E+07 4.92E+04 3.44E+02 2.35E+06 1.51E+04 2.06E+03 0.133 0.156 0.952 2.850 P324 Position #7 CTMT AUX Grouted 4.04E+06 1.59E+05 7.03E+07 4.82E+04 3.37E+02 2.30E+06 1.48E+04 2.02E+03 0.130 0.153 0.932 2.792 P324 Position #8 CTMT AUX Grouted 4.29E+06 1.69E+05 7.45E+07 5.12E+04 3.57E+02 2.44E+06 1.57E+04 2.14E+03 0.138 0.162 0.989 2.961 P324 Position #9 CTMT AUX Grouted 4.59E+06 1.80E+05 7.97E+07 5.47E+04 3.82E+02 2.61E+06 1.68E+04 2.29E+03 0.148 0.173 1.058 3.167 P324 Position #10 CTMT AUX Grouted 4.17E+06 1.64E+05 7.24E+07 4.97E+04 3.47E+02 2.37E+06 1.53E+04 2.08E+03 0.134 0.158 0.961 2.877 P324 Position #11 CTMT AUX Grouted 3.98E+06 1.57E+05 6.92E+07 4.75E+04 3.32E+02 2.26E+06 1.46E+04 1.99E+03 0.128 0.151 0.918 2.748 P324 Position #12 CTMT AUX Grouted 4.09E+06 1.61E+05 7.10E+07 4.87E+04 3.41E+02 2.32E+06 1.50E+04 2.04E+03 0.132 0.155 0.942 2.821 MEASUREMENT ID BETWEEN END STATE
~
=ZIONSOLUTIONSuc-An Er,e,,gyS~ Company
FSS RELEASE RECORD, REV 1 PENETRATIONS SURVEY UNITS 01112, 02112 and 05120
[82]
Unit 2 Containment Penetration Measurements (continued)
H-3 (1)
Co-60 (2)
Ni-63 (1)
Sr-90 (1)
Cs-134 (2)
Cs-137 (2)
Eu-152 (2)
Eu-154 (2)
OpSOFPN OpSOFPN OpSOFB OpSOFB (pCi/m2)
(pCi/m2)
(pCi/m2)
(pCi/m2)
(pCi/m2)
(pCi/m2)
(pCi/m2)
(pCi/m2)
CTMTPN Limiting DCGL CTMT DCGL Limiting DCGL P324 Position #13 CTMT AUX Grouted 4.03E+06 1.59E+05 7.01E+07 4.81E+04 3.36E+02 2.29E+06 1.48E+04 2.02E+03 0.130 0.153 0.930 2.786 P324 Position #14 CTMT AUX Grouted 4.09E+06 1.61E+05 7.11E+07 4.88E+04 3.41E+02 2.32E+06 1.50E+04 2.05E+03 0.132 0.155 0.943 2.825 P324 Position #15 CTMT AUX Grouted 4.13E+06 1.63E+05 7.19E+07 4.93E+04 3.45E+02 2.35E+06 1.52E+04 2.07E+03 0.133 0.156 0.953 2.855 P324 Position #16 CTMT AUX Grouted 4.22E+06 1.66E+05 7.34E+07 5.04E+04 3.52E+02 2.40E+06 1.55E+04 2.11E+03 0.136 0.160 0.974 2.916 P324 Position #17 CTMT AUX Grouted 4.85E+06 1.91E+05 8.43E+07 5.79E+04 4.04E+02 2.76E+06 1.78E+04 2.43E+03 0.157 0.183 1.118 3.350 P324 Position #18 CTMT AUX Grouted 5.13E+06 2.02E+05 8.93E+07 6.13E+04 4.28E+02 2.92E+06 1.88E+04 2.57E+03 0.166 0.194 1.184 3.546 P324 Position #19 CTMT AUX Grouted 4.41E+06 1.74E+05 7.68E+07 5.27E+04 3.68E+02 2.51E+06 1.62E+04 2.21E+03 0.142 0.167 1.018 3.049 P324 Position #20 CTMT AUX Grouted 4.23E+06 1.66E+05 7.35E+07 5.04E+04 3.52E+02 2.40E+06 1.55E+04 2.11E+03 0.136 0.160 0.975 2.920 P324 Position #21 CTMT AUX Grouted 4.49E+06 1.77E+05 7.80E+07 5.36E+04 3.74E+02 2.55E+06 1.65E+04 2.24E+03 0.145 0.170 1.035 3.100 P324 Position #22 CTMT AUX Grouted 4.16E+06 1.64E+05 7.24E+07 4.97E+04 3.47E+02 2.36E+06 1.53E+04 2.08E+03 0.134 0.157 0.960 2.874 P324 Position #23 CTMT AUX Grouted 3.73E+06 1.47E+05 6.49E+07 4.45E+04 3.11E+02 2.12E+06 1.37E+04 1.87E+03 0.120 0.141 0.860 2.576 P324 Position #24 CTMT AUX Grouted 3.69E+06 1.45E+05 6.41E+07 4.40E+04 3.07E+02 2.10E+06 1.35E+04 1.84E+03 0.119 0.140 0.851 2.547 P324 Position #25 CTMT AUX Grouted 3.67E+06 1.44E+05 6.38E+07 4.38E+04 3.06E+02 2.08E+06 1.35E+04 1.83E+03 0.118 0.139 0.846 2.533 P324 Position #26 CTMT AUX Grouted 5.00E+06 1.97E+05 8.70E+07 5.97E+04 4.17E+02 2.84E+06 1.84E+04 2.50E+03 0.161 0.189 1.154 3.456 P324 Position #27 CTMT AUX Grouted 6.30E+06 2.48E+05 1.10E+08 7.52E+04 5.25E+02 3.58E+06 2.31E+04 3.15E+03 0.203 0.238 1.453 4.351 P324 Position #28 CTMT AUX Grouted 4.13E+06 1.63E+05 7.18E+07 4.93E+04 3.44E+02 2.35E+06 1.52E+04 2.07E+03 0.133 0.156 0.953 2.854 P324 Position #29 CTMT AUX Grouted 3.71E+06 1.46E+05 6.45E+07 4.42E+04 3.09E+02 2.11E+06 1.36E+04 1.85E+03 0.120 0.140 0.855 2.561 P324 Position #30 CTMT AUX Grouted 3.63E+06 1.43E+05 6.31E+07 4.33E+04 3.02E+02 2.06E+06 1.33E+04 1.81E+03 0.117 0.137 0.837 2.506 P324 Position #31 CTMT AUX Grouted 3.53E+06 1.39E+05 6.14E+07 4.21E+04 2.94E+02 2.01E+06 1.30E+04 1.77E+03 0.114 0.134 0.815 2.439 P324 Position #32 CTMT AUX Grouted 3.59E+06 1.41E+05 6.24E+07 4.28E+04 2.99E+02 2.04E+06 1.32E+04 1.79E+03 0.116 0.136 0.827 2.478 P324 Position #33 CTMT AUX Grouted 3.73E+06 1.47E+05 6.48E+07 4.45E+04 3.11E+02 2.12E+06 1.37E+04 1.86E+03 0.120 0.141 0.860 2.575 P324 Position #34 CTMT AUX Grouted 4.21E+06 1.65E+05 7.31E+07 5.02E+04 3.51E+02 2.39E+06 1.54E+04 2.10E+03 0.136 0.159 0.970 2.905 P324 Position #35 CTMT AUX Grouted 6.98E+06 2.74E+05 1.21E+08 8.32E+04 5.81E+02 3.96E+06 2.56E+04 3.49E+03 0.225 0.264 1.609 4.817 P324 Position #36 CTMT AUX Grouted 8.05E+06 3.17E+05 1.40E+08 9.61E+04 6.71E+02 4.57E+06 2.95E+04 4.03E+03 0.260 0.305 1.856 5.559 P324 Position #37 CTMT AUX Grouted 6.37E+06 2.51E+05 1.11E+08 7.61E+04 5.31E+02 3.62E+06 2.34E+04 3.19E+03 0.206 0.241 1.470 4.402 P324 Position #38 CTMT AUX Grouted 4.67E+06 1.84E+05 8.12E+07 5.57E+04 3.89E+02 2.65E+06 1.71E+04 2.33E+03 0.151 0.177 1.077 3.224 P324 Position #39 CTMT AUX Grouted 4.13E+06 1.62E+05 7.18E+07 4.92E+04 3.44E+02 2.35E+06 1.51E+04 2.06E+03 0.133 0.156 0.952 2.850 P324 Position #40 CTMT AUX Grouted 3.76E+06 1.48E+05 6.55E+07 4.49E+04 3.14E+02 2.14E+06 1.38E+04 1.88E+03 0.121 0.142 0.868 2.600 P324 Position #41 CTMT AUX Grouted 3.69E+06 1.45E+05 6.42E+07 4.41E+04 3.08E+02 2.10E+06 1.35E+04 1.85E+03 0.119 0.140 0.852 2.551 P324 Position #42 CTMT AUX Grouted 3.72E+06 1.46E+05 6.47E+07 4.44E+04 3.10E+02 2.12E+06 1.37E+04 1.86E+03 0.120 0.141 0.859 2.571 P324 Position #43 CTMT AUX Grouted 4.20E+06 1.65E+05 7.30E+07 5.01E+04 3.50E+02 2.39E+06 1.54E+04 2.10E+03 0.136 0.159 0.969 2.901 P324 Position #44 CTMT AUX Grouted 7.17E+06 2.82E+05 1.25E+08 8.55E+04 5.97E+02 4.07E+06 2.63E+04 3.58E+03 0.231 0.271 1.653 4.950 P324 Position #45 CTMT AUX Grouted 6.00E+06 2.36E+05 1.04E+08 7.16E+04 5.00E+02 3.41E+06 2.20E+04 3.00E+03 0.193 0.227 1.383 4.141 P324 Position #46 CTMT AUX Grouted 4.43E+06 1.74E+05 7.70E+07 5.28E+04 3.69E+02 2.51E+06 1.62E+04 2.21E+03 0.143 0.167 1.021 3.056 P324 Position #47 CTMT AUX Grouted 4.34E+06 1.71E+05 7.54E+07 5.17E+04 3.61E+02 2.46E+06 1.59E+04 2.17E+03 0.140 0.164 1.000 2.994 P324 Position #48 CTMT AUX Grouted 4.74E+06 1.86E+05 8.24E+07 5.65E+04 3.95E+02 2.69E+06 1.74E+04 2.37E+03 0.153 0.179 1.092 3.271 P324 Position #49 CTMT AUX Grouted 5.99E+06 2.36E+05 1.04E+08 7.15E+04 4.99E+02 3.40E+06 2.20E+04 2.99E+03 0.193 0.227 1.381 4.136 P324 Position #50 CTMT AUX Grouted 5.70E+06 2.24E+05 9.91E+07 6.80E+04 4.75E+02 3.24E+06 2.09E+04 2.85E+03 0.184 0.216 1.314 3.936 P220 By Direct Scan CTMT AUX Removed 7.07E+04 2.78E+03 1.23E+06 8.43E+02 5.89E+00 4.02E+04 2.59E+02 3.53E+01 0.002 0.003 0.016 0.049 P292 By Direct Scan CTMT TB Open/Buried 9.54E+04 3.75E+03 1.66E+06 1.14E+03 7.95E+00 5.42E+04 3.50E+02 4.77E+01 0.003 0.004 0.022 0.066 P209 By Direct Scan CTMT TB Open/Buried 1.34E+05 5.26E+03 2.33E+06 1.60E+03 1.11E+01 7.60E+04 4.90E+02 6.69E+01 0.004 0.005 0.031 0.092 P205 By Direct Scan CTMT TB Open/Buried 2.00E+05 7.87E+03 3.48E+06 2.39E+03 1.67E+01 1.14E+05 7.33E+02 1.00E+02 0.006 0.008 0.046 0.138 P205 By Direct Scan CTMT TB Open/Buried 1.93E+05 7.58E+03 3.35E+06 2.30E+03 1.61E+01 1.09E+05 7.06E+02 9.63E+01 0.006 0.007 0.044 0.133 P327 By Direct Scan CTMT TB Open/Buried 1.09E+05 4.30E+03 1.90E+06 1.30E+03 9.11E+00 6.21E+04 4.01E+02 5.46E+01 0.004 0.004 0.025 0.075 P211 By Direct Scan CTMT TB Open/Buried 1.27E+05 5.01E+03 2.21E+06 1.52E+03 1.06E+01 7.23E+04 4.67E+02 6.36E+01 0.004 0.005 0.029 0.088 P315 By Direct Scan CTMT TB Open/Buried 6.86E+04 2.70E+03 1.19E+06 8.19E+02 5.72E+00 3.90E+04 2.52E+02 3.43E+01 0.002 0.003 0.016 0.047 P207 By Direct Scan CTMT TB Open/Buried 4.98E+04 1.96E+03 8.65E+05 5.94E+02 4.15E+00 2.83E+04 1.83E+02 2.49E+01 0.002 0.002 0.011 0.034 P296 By Direct Scan CTMT TB Open/Buried 6.74E+04 2.65E+03 1.17E+06 8.05E+02 5.62E+00 3.83E+04 2.47E+02 3.37E+01 0.002 0.003 0.016 0.047 P208 By Direct Scan CTMT TB Open/Buried 4.68E+04 1.84E+03 8.13E+05 5.58E+02 3.90E+00 2.66E+04 1.71E+02 2.34E+01 0.002 0.002 0.011 0.032 P318 By Direct Scan CTMT TB Open/Buried 5.78E+04 2.27E+03 1.01E+06 6.90E+02 4.82E+00 3.28E+04 2.12E+02 2.89E+01 0.002 0.002 0.013 0.040 P317 By Direct Scan CTMT TB Open/Buried 5.23E+04 2.06E+03 9.09E+05 6.24E+02 4.36E+00 2.97E+04 1.92E+02 2.61E+01 0.002 0.002 0.012 0.036 MEASUREMENT ID BETWEEN END STATE
~
=ZIONSOLUTIONSuc-An Er,e,,gyS~ Company
FSS RELEASE RECORD, REV 1 PENETRATIONS SURVEY UNITS 01112, 02112 and 05120
[83]
Unit 2 Containment Penetration Measurements (continued)
H-3 (1)
Co-60 (2)
Ni-63 (1)
Sr-90 (1)
Cs-134 (2)
Cs-137 (2)
Eu-152 (2)
Eu-154 (2)
OpSOFPN OpSOFPN OpSOFB OpSOFB (pCi/m2)
(pCi/m2)
(pCi/m2)
(pCi/m2)
(pCi/m2)
(pCi/m2)
(pCi/m2)
(pCi/m2)
CTMTPN Limiting DCGL CTMT DCGL Limiting DCGL P212 By Direct Scan CTMT TB Open/Buried 6.04E+04 2.38E+03 1.05E+06 7.20E+02 5.03E+00 3.43E+04 2.21E+02 3.02E+01 0.002 0.002 0.014 0.042 P298 By Direct Scan CTMT TB Open/Buried 4.49E+04 1.77E+03 7.81E+05 5.36E+02 3.74E+00 2.55E+04 1.65E+02 2.25E+01 0.001 0.002 0.010 0.031 P313 By Direct Scan CTMT TB Open/Buried 4.23E+04 1.67E+03 7.36E+05 5.05E+02 3.53E+00 2.41E+04 1.55E+02 2.12E+01 0.001 0.002 0.010 0.029 P297 By Direct Scan CTMT TB Open/Buried 4.23E+04 1.67E+03 7.36E+05 5.05E+02 3.53E+00 2.41E+04 1.55E+02 2.12E+01 0.001 0.002 0.010 0.029 P328 By Direct Scan CTMT TB Open/Buried 4.68E+04 1.84E+03 8.13E+05 5.58E+02 3.90E+00 2.66E+04 1.71E+02 2.34E+01 0.002 0.002 0.011 0.032 P316 By Direct Scan CTMT TB Open/Buried 7.14E+04 2.81E+03 1.24E+06 8.52E+02 5.95E+00 4.06E+04 2.62E+02 3.57E+01 0.002 0.003 0.016 0.049 P294 By Direct Scan CTMT TB Open/Buried 3.94E+04 1.55E+03 6.85E+05 4.70E+02 3.28E+00 2.24E+04 1.44E+02 1.97E+01 0.001 0.001 0.009 0.027 P293 By Direct Scan CTMT TB Open/Buried 5.41E+04 2.13E+03 9.41E+05 6.46E+02 4.51E+00 3.07E+04 1.98E+02 2.71E+01 0.002 0.002 0.012 0.037 P210 By Direct Scan CTMT TB Open/Buried 1.31E+05 5.14E+03 2.27E+06 1.56E+03 1.09E+01 7.43E+04 4.79E+02 6.54E+01 0.004 0.005 0.030 0.090 P312 By Direct Scan CTMT TB Open/Buried 5.71E+04 2.24E+03 9.92E+05 6.81E+02 4.76E+00 3.24E+04 2.09E+02 2.85E+01 0.002 0.002 0.013 0.039 P295 By Direct Scan CTMT TB Open/Buried 5.60E+04 2.20E+03 9.73E+05 6.68E+02 4.66E+00 3.18E+04 2.05E+02 2.80E+01 0.002 0.002 0.013 0.039 P291 By Direct Scan CTMT TB Open/Buried 9.06E+04 3.56E+03 1.57E+06 1.08E+03 7.55E+00 5.15E+04 3.32E+02 4.53E+01 0.003 0.003 0.021 0.063 MEASUREMENT ID BETWEEN END STATE
~
=ZIONSOLUTIONSuc-An Er,e,,gyS~ Company
FSS RELEASE RECORD, REV 1 PENETRATIONS SURVEY UNITS 01112, 02112 and 05120
[84]
Auxiliary Building Penetration Measurements H-3 (1)
Co-60 (2)
Ni-63 (1)
Sr-90 (1)
Cs-134 (2)
Cs-137 (2)
Eu-152 (2)
Eu-154 (2)
OpSOFPN OpSOFPN OpSOFB OpSOFB (pCi/m2)
(pCi/m2)
(pCi/m2)
(pCi/m2)
(pCi/m2)
(pCi/m2)
(pCi/m2)
(pCi/m2)
CTMTPN Limiting DCGL CTMT/AB DCGL Limiting DCGL P001 Position #1 CTMT AUX Removed 1.06E+07 4.18E+05 1.85E+08 1.27E+05 8.86E+02 6.04E+06 3.90E+04 5.31E+03 0.343 0.402 2.451 7.339 P001 Position #2 CTMT AUX Removed 2.96E+06 1.16E+05 5.14E+07 3.53E+04 2.46E+02 1.68E+06 1.08E+04 1.48E+03 0.095 0.112 0.682 2.042 P001 Position #3 CTMT AUX Removed 1.77E+06 6.98E+04 3.08E+07 2.12E+04 1.48E+02 1.01E+06 6.51E+03 8.87E+02 0.057 0.067 0.409 1.225 P001 Position #4 CTMT AUX Removed 1.62E+06 6.37E+04 2.82E+07 1.93E+04 1.35E+02 9.21E+05 5.94E+03 8.10E+02 0.052 0.061 0.374 1.119 P001 Position #5 CTMT AUX Removed 3.08E+06 1.21E+05 5.35E+07 3.67E+04 2.56E+02 1.75E+06 1.13E+04 1.54E+03 0.099 0.116 0.709 2.124 P086 Position #1 CTMT AUX Removed 2.48E+06 9.77E+04 4.32E+07 2.96E+04 2.07E+02 1.41E+06 9.11E+03 1.24E+03 0.080 0.094 0.573 1.715 P086 Position #2 CTMT AUX Removed 7.87E+06 3.10E+05 1.37E+08 9.39E+04 6.56E+02 4.47E+06 2.89E+04 3.94E+03 0.254 0.298 1.816 5.437 P086 Position #3 CTMT AUX Removed 2.06E+06 8.11E+04 3.58E+07 2.46E+04 1.72E+02 1.17E+06 7.56E+03 1.03E+03 0.067 0.078 0.475 1.424 P086 Position #4 CTMT AUX Removed 1.51E+06 5.93E+04 2.62E+07 1.80E+04 1.26E+02 8.56E+05 5.53E+03 7.54E+02 0.049 0.057 0.348 1.041 P086 Position #5 CTMT AUX Removed 1.62E+06 6.38E+04 2.82E+07 1.94E+04 1.35E+02 9.22E+05 5.95E+03 8.11E+02 0.052 0.061 0.374 1.120 P019 Position #1 CTMT AUX Removed 7.00E+06 2.75E+05 1.22E+08 8.35E+04 5.83E+02 3.97E+06 2.57E+04 3.50E+03 0.226 0.265 1.613 4.831 P019 Position #2 CTMT AUX Removed 2.13E+06 8.39E+04 3.71E+07 2.54E+04 1.78E+02 1.21E+06 7.82E+03 1.07E+03 0.069 0.081 0.492 1.473 P019 Position #3 CTMT AUX Removed 1.48E+06 5.83E+04 2.58E+07 1.77E+04 1.23E+02 8.42E+05 5.43E+03 7.41E+02 0.048 0.056 0.342 1.023 P019 Position #4 CTMT AUX Removed 1.38E+06 5.42E+04 2.39E+07 1.64E+04 1.15E+02 7.82E+05 5.05E+03 6.88E+02 0.044 0.052 0.317 0.951 P019 Position #5 CTMT AUX Removed 1.53E+06 6.03E+04 2.66E+07 1.83E+04 1.28E+02 8.70E+05 5.62E+03 7.66E+02 0.049 0.058 0.353 1.058 P023 Position #1 CTMT AUX Removed 9.94E+06 3.91E+05 1.73E+08 1.19E+05 8.28E+02 5.65E+06 3.64E+04 4.97E+03 0.321 0.376 2.291 6.862 P023 Position #2 CTMT AUX Removed 2.39E+06 9.41E+04 4.16E+07 2.85E+04 1.99E+02 1.36E+06 8.77E+03 1.20E+03 0.077 0.090 0.551 1.651 P023 Position #3 CTMT AUX Removed 1.57E+06 6.18E+04 2.73E+07 1.87E+04 1.31E+02 8.92E+05 5.76E+03 7.85E+02 0.051 0.059 0.362 1.084 P023 Position #4 CTMT AUX Removed 1.51E+06 5.94E+04 2.63E+07 1.80E+04 1.26E+02 8.58E+05 5.54E+03 7.55E+02 0.049 0.057 0.348 1.043 P023 Position #5 CTMT AUX Removed 1.94E+06 7.63E+04 3.37E+07 2.31E+04 1.62E+02 1.10E+06 7.11E+03 9.70E+02 0.063 0.073 0.447 1.339 P088 Position #1 CTMT AUX Removed 6.16E+06 2.42E+05 1.07E+08 7.34E+04 5.13E+02 3.50E+06 2.26E+04 3.08E+03 0.199 0.233 1.419 4.251 P088 Position #2 CTMT AUX Removed 2.02E+06 7.94E+04 3.51E+07 2.41E+04 1.68E+02 1.15E+06 7.41E+03 1.01E+03 0.065 0.076 0.466 1.395 P088 Position #3 CTMT AUX Removed 1.58E+06 6.21E+04 2.74E+07 1.88E+04 1.32E+02 8.97E+05 5.79E+03 7.89E+02 0.051 0.060 0.364 1.090 P088 Position #4 CTMT AUX Removed 1.47E+06 5.77E+04 2.55E+07 1.75E+04 1.22E+02 8.33E+05 5.38E+03 7.34E+02 0.047 0.055 0.338 1.013 P088 Position #5 CTMT AUX Removed 1.74E+06 6.86E+04 3.03E+07 2.08E+04 1.45E+02 9.91E+05 6.40E+03 8.73E+02 0.056 0.066 0.402 1.205 P089 Position #1 CTMT AUX Removed 8.09E+06 3.18E+05 1.41E+08 9.66E+04 6.75E+02 4.60E+06 2.97E+04 4.05E+03 0.261 0.306 1.867 5.590 P089 Position #2 CTMT AUX Removed 2.83E+06 1.11E+05 4.92E+07 3.37E+04 2.36E+02 1.61E+06 1.04E+04 1.41E+03 0.091 0.107 0.652 1.953 P089 Position #3 CTMT AUX Removed 1.87E+06 7.37E+04 3.26E+07 2.24E+04 1.56E+02 1.06E+06 6.87E+03 9.37E+02 0.060 0.071 0.432 1.294 P089 Position #4 CTMT AUX Removed 1.62E+06 6.36E+04 2.81E+07 1.93E+04 1.35E+02 9.18E+05 5.92E+03 8.08E+02 0.052 0.061 0.373 1.116 P089 Position #5 CTMT AUX Removed 2.16E+06 8.52E+04 3.76E+07 2.58E+04 1.80E+02 1.23E+06 7.94E+03 1.08E+03 0.070 0.082 0.499 1.495 P004 Position #1 CTMT AUX Removed 8.59E+06 3.38E+05 1.49E+08 1.02E+05 7.16E+02 4.88E+06 3.15E+04 4.29E+03 0.277 0.325 1.981 5.931 P004 Position #2 CTMT AUX Removed 1.75E+06 6.89E+04 3.04E+07 2.09E+04 1.46E+02 9.95E+05 6.42E+03 8.75E+02 0.056 0.066 0.404 1.209 P004 Position #3 CTMT AUX Removed 1.54E+06 6.06E+04 2.68E+07 1.84E+04 1.28E+02 8.76E+05 5.65E+03 7.71E+02 0.050 0.058 0.355 1.064 P004 Position #4 CTMT AUX Removed 1.60E+06 6.29E+04 2.78E+07 1.91E+04 1.33E+02 9.08E+05 5.86E+03 7.99E+02 0.052 0.060 0.369 1.104 P004 Position #5 CTMT AUX Removed 1.79E+06 7.05E+04 3.12E+07 2.14E+04 1.49E+02 1.02E+06 6.57E+03 8.96E+02 0.058 0.068 0.413 1.237 P042 Position #1 CTMT AUX Removed 8.00E+06 3.15E+05 1.39E+08 9.54E+04 6.66E+02 4.54E+06 2.93E+04 4.00E+03 0.258 0.302 1.844 5.522 P042 Position #2 CTMT AUX Removed 2.95E+06 1.16E+05 5.14E+07 3.53E+04 2.46E+02 1.68E+06 1.08E+04 1.48E+03 0.095 0.112 0.681 2.041 P042 Position #3 CTMT AUX Removed 2.69E+06 1.06E+05 4.68E+07 3.21E+04 2.24E+02 1.53E+06 9.86E+03 1.35E+03 0.087 0.102 0.620 1.858 P042 Position #4 CTMT AUX Removed 1.55E+06 6.09E+04 2.69E+07 1.85E+04 1.29E+02 8.79E+05 5.67E+03 7.74E+02 0.050 0.059 0.357 1.068 P042 Position #5 CTMT AUX Removed 3.18E+06 1.25E+05 5.52E+07 3.79E+04 2.65E+02 1.80E+06 1.16E+04 1.59E+03 0.102 0.120 0.733 2.194 P043 Position #1 CTMT AUX Removed 8.10E+06 3.18E+05 1.41E+08 9.66E+04 6.75E+02 4.60E+06 2.97E+04 4.05E+03 0.261 0.306 1.867 5.591 P043 Position #2 CTMT AUX Removed 1.96E+06 7.69E+04 3.40E+07 2.33E+04 1.63E+02 1.11E+06 7.17E+03 9.78E+02 0.063 0.074 0.451 1.351 P043 Position #3 CTMT AUX Removed 2.04E+06 8.03E+04 3.55E+07 2.44E+04 1.70E+02 1.16E+06 7.49E+03 1.02E+03 0.066 0.077 0.471 1.410 P043 Position #4 CTMT AUX Removed 2.29E+06 9.00E+04 3.98E+07 2.73E+04 1.91E+02 1.30E+06 8.39E+03 1.14E+03 0.074 0.087 0.528 1.581 P043 Position #5 CTMT AUX Removed 3.83E+06 1.51E+05 6.67E+07 4.57E+04 3.20E+02 2.18E+06 1.41E+04 1.92E+03 0.124 0.145 0.884 2.648 P054 Position #1 CTMT AUX Removed 7.30E+06 2.87E+05 1.27E+08 8.71E+04 6.08E+02 4.15E+06 2.68E+04 3.65E+03 0.236 0.276 1.684 5.042 P054 Position #2 CTMT AUX Removed 1.66E+06 6.55E+04 2.89E+07 1.99E+04 1.39E+02 9.46E+05 6.10E+03 8.32E+02 0.054 0.063 0.384 1.149 P054 Position #3 CTMT AUX Removed 1.73E+06 6.82E+04 3.01E+07 2.07E+04 1.45E+02 9.85E+05 6.36E+03 8.67E+02 0.056 0.066 0.400 1.197 P054 Position #4 CTMT AUX Removed 2.06E+06 8.09E+04 3.57E+07 2.45E+04 1.71E+02 1.17E+06 7.54E+03 1.03E+03 0.066 0.078 0.474 1.419 P054 Position #5 CTMT AUX Removed 2.19E+06 8.60E+04 3.80E+07 2.61E+04 1.82E+02 1.24E+06 8.02E+03 1.09E+03 0.071 0.083 0.504 1.509 P081 Position #1 CTMT AUX Removed 6.20E+06 2.44E+05 1.08E+08 7.40E+04 5.17E+02 3.53E+06 2.28E+04 3.10E+03 0.200 0.235 1.431 4.285 P081 Position #2 CTMT AUX Removed 1.87E+06 7.36E+04 3.25E+07 2.23E+04 1.56E+02 1.06E+06 6.86E+03 9.35E+02 0.060 0.071 0.431 1.291 P081 Position #3 CTMT AUX Removed 1.79E+06 7.03E+04 3.11E+07 2.13E+04 1.49E+02 1.02E+06 6.56E+03 8.94E+02 0.058 0.068 0.412 1.234 MEASUREMENT ID BETWEEN END STATE
~
=ZIONSOLUTIONSuc-An Er,e,,gyS~ Company
FSS RELEASE RECORD, REV 1 PENETRATIONS SURVEY UNITS 01112, 02112 and 05120
[85]
Auxiliary Building Penetration Measurements (continued)
H-3 (1)
Co-60 (2)
Ni-63 (1)
Sr-90 (1)
Cs-134 (2)
Cs-137 (2)
Eu-152 (2)
Eu-154 (2)
OpSOFPN OpSOFPN OpSOFB OpSOFB (pCi/m2)
(pCi/m2)
(pCi/m2)
(pCi/m2)
(pCi/m2)
(pCi/m2)
(pCi/m2)
(pCi/m2)
CTMTPN Limiting DCGL CTMT/AB DCGL Limiting DCGL P081 Position #4 CTMT AUX Removed 1.85E+06 7.26E+04 3.21E+07 2.20E+04 1.54E+02 1.05E+06 6.77E+03 9.23E+02 0.060 0.070 0.425 1.274 P081 Position #5 CTMT AUX Removed 2.62E+06 1.03E+05 4.56E+07 3.13E+04 2.19E+02 1.49E+06 9.61E+03 1.31E+03 0.085 0.099 0.605 1.811 P104 By Direct Scan CTMT AUX Removed 1.08E+05 4.26E+03 1.88E+06 1.29E+03 9.03E+00 6.16E+04 3.97E+02 5.42E+01 0.003 0.004 0.025 0.075 P022 By Direct Scan CTMT AUX Removed 1.03E+06 4.07E+04 1.80E+07 1.23E+04 8.62E+01 5.87E+05 3.79E+03 5.17E+02 0.033 0.039 0.238 0.714 P074 By Direct Scan CTMT AUX Removed 9.40E+04 3.70E+03 1.63E+06 1.12E+03 7.83E+00 5.34E+04 3.45E+02 4.70E+01 0.003 0.004 0.022 0.065 P123 Position #1 CTMT AUX Grouted 2.13E+08 8.37E+06 3.70E+09 2.54E+06 1.77E+04 1.21E+08 7.80E+05 1.06E+05 6.864 8.048 49.060 146.918 P123 Position #2 CTMT AUX Grouted 2.42E+08 9.53E+06 4.21E+09 2.89E+06 2.02E+04 1.38E+08 8.89E+05 1.21E+05 7.819 9.166 55.878 167.337 P123 Position #3 CTMT AUX Grouted 2.67E+08 1.05E+07 4.63E+09 3.18E+06 2.22E+04 1.51E+08 9.77E+05 1.33E+05 8.600 10.082 61.460 184.052 P123 Position #4 CTMT AUX Grouted 2.58E+08 1.01E+07 4.48E+09 3.07E+06 2.15E+04 1.46E+08 9.44E+05 1.29E+05 8.310 9.743 59.392 177.860 P123 Position #5 CTMT AUX Grouted 2.37E+08 9.31E+06 4.11E+09 2.82E+06 1.97E+04 1.34E+08 8.68E+05 1.18E+05 7.635 8.951 54.568 163.414 P123 Position #6 CTMT AUX Grouted 2.10E+08 8.25E+06 3.65E+09 2.50E+06 1.75E+04 1.19E+08 7.69E+05 1.05E+05 6.764 7.930 48.342 144.768 P123 Position #7 CTMT AUX Grouted 1.96E+08 7.71E+06 3.41E+09 2.34E+06 1.63E+04 1.11E+08 7.18E+05 9.80E+04 6.321 7.411 45.178 135.294 P123 Position #8 CTMT AUX Grouted 1.83E+08 7.21E+06 3.19E+09 2.19E+06 1.53E+04 1.04E+08 6.72E+05 9.17E+04 5.915 6.935 42.274 126.597 P123 Position #9 CTMT AUX Grouted 1.73E+08 6.80E+06 3.01E+09 2.06E+06 1.44E+04 9.83E+07 6.34E+05 8.65E+04 5.581 6.543 39.886 119.446 P123 Position #10 CTMT AUX Grouted 1.84E+08 7.26E+06 3.21E+09 2.20E+06 1.54E+04 1.05E+08 6.76E+05 9.22E+04 5.951 6.977 42.533 127.374 P123 Position #11 CTMT AUX Grouted 1.93E+08 7.61E+06 3.36E+09 2.31E+06 1.61E+04 1.10E+08 7.10E+05 9.68E+04 6.243 7.319 44.617 133.613 P123 Position #12 CTMT AUX Grouted 1.93E+08 7.60E+06 3.36E+09 2.30E+06 1.61E+04 1.10E+08 7.08E+05 9.66E+04 6.231 7.305 44.532 133.359 P123 Position #13 CTMT AUX Grouted 2.03E+08 7.99E+06 3.53E+09 2.42E+06 1.69E+04 1.15E+08 7.45E+05 1.02E+05 6.555 7.685 46.850 140.300 P123 Position #14 CTMT AUX Grouted 1.81E+08 7.13E+06 3.15E+09 2.16E+06 1.51E+04 1.03E+08 6.64E+05 9.06E+04 5.845 6.853 41.776 125.105 P123 Position #15 CTMT AUX Grouted 1.41E+08 5.54E+06 2.45E+09 1.68E+06 1.17E+04 8.00E+07 5.16E+05 7.04E+04 4.544 5.327 32.475 97.251 P123 Position #16 CTMT AUX Grouted 1.19E+08 4.68E+06 2.07E+09 1.42E+06 9.92E+03 6.76E+07 4.37E+05 5.95E+04 3.841 4.503 27.452 82.211 P123 Position #17 CTMT AUX Grouted 1.11E+08 4.37E+06 1.93E+09 1.32E+06 9.25E+03 6.31E+07 4.07E+05 5.55E+04 3.582 4.200 25.603 76.673 P123 Position #18 CTMT AUX Grouted 1.07E+08 4.21E+06 1.86E+09 1.28E+06 8.93E+03 6.09E+07 3.93E+05 5.36E+04 3.456 4.052 24.700 73.968 P123 Position #19 CTMT AUX Grouted 1.11E+08 4.35E+06 1.92E+09 1.32E+06 9.22E+03 6.29E+07 4.06E+05 5.53E+04 3.570 4.185 25.512 76.399 P123 Position #20 CTMT AUX Grouted 8.98E+07 3.53E+06 1.56E+09 1.07E+06 7.48E+03 5.10E+07 3.29E+05 4.49E+04 2.897 3.396 20.701 61.994 P123 Position #21 CTMT AUX Grouted 6.62E+07 2.61E+06 1.15E+09 7.90E+05 5.52E+03 3.76E+07 2.43E+05 3.31E+04 2.137 2.505 15.271 45.733 P123 Position #22 CTMT AUX Grouted 5.80E+07 2.28E+06 1.01E+09 6.92E+05 4.83E+03 3.29E+07 2.13E+05 2.90E+04 1.870 2.193 13.366 40.028 P123 Position #23 CTMT AUX Grouted 4.22E+07 1.66E+06 7.34E+08 5.04E+05 3.52E+03 2.40E+07 1.55E+05 2.11E+04 1.362 1.597 9.734 29.150 P123 Position #24 CTMT AUX Grouted 2.32E+07 9.14E+05 4.04E+08 2.77E+05 1.94E+03 1.32E+07 8.52E+04 1.16E+04 0.749 0.879 5.356 16.041 P123 Position #25 CTMT AUX Grouted 1.82E+07 7.14E+05 3.16E+08 2.17E+05 1.51E+03 1.03E+07 6.66E+04 9.08E+03 0.586 0.687 4.186 12.536 P123 Position #26 CTMT AUX Grouted 1.51E+07 5.93E+05 2.62E+08 1.80E+05 1.26E+03 8.57E+06 5.53E+04 7.54E+03 0.487 0.571 3.478 10.417 P123 Position #27 CTMT AUX Grouted 1.50E+07 5.89E+05 2.60E+08 1.79E+05 1.25E+03 8.51E+06 5.49E+04 7.49E+03 0.483 0.567 3.455 10.346 P123 Position #28 CTMT AUX Grouted 1.17E+07 4.60E+05 2.03E+08 1.39E+05 9.74E+02 6.64E+06 4.28E+04 5.84E+03 0.377 0.442 2.694 8.068 P123 Position #29 CTMT AUX Grouted 8.87E+06 3.49E+05 1.54E+08 1.06E+05 7.40E+02 5.04E+06 3.25E+04 4.44E+03 0.286 0.336 2.046 6.128 P123 Position #30 CTMT AUX Grouted 7.70E+06 3.03E+05 1.34E+08 9.19E+04 6.42E+02 4.37E+06 2.82E+04 3.85E+03 0.248 0.291 1.776 5.317 P123 Position #31 CTMT AUX Grouted 7.24E+06 2.85E+05 1.26E+08 8.64E+04 6.04E+02 4.12E+06 2.66E+04 3.62E+03 0.234 0.274 1.670 5.002 P123 Position #32 CTMT AUX Grouted 6.98E+06 2.75E+05 1.21E+08 8.33E+04 5.82E+02 3.97E+06 2.56E+04 3.49E+03 0.225 0.264 1.610 4.823 P123 Position #33 CTMT AUX Grouted 7.33E+06 2.89E+05 1.28E+08 8.75E+04 6.11E+02 4.17E+06 2.69E+04 3.67E+03 0.237 0.277 1.691 5.065 P123 Position #34 CTMT AUX Grouted 8.01E+06 3.15E+05 1.39E+08 9.55E+04 6.67E+02 4.55E+06 2.94E+04 4.00E+03 0.258 0.303 1.846 5.529 P123 Position #35 CTMT AUX Grouted 9.98E+06 3.93E+05 1.74E+08 1.19E+05 8.32E+02 5.67E+06 3.66E+04 4.99E+03 0.322 0.378 2.302 6.894 P123 Position #36 CTMT AUX Grouted 8.07E+06 3.18E+05 1.40E+08 9.63E+04 6.73E+02 4.59E+06 2.96E+04 4.04E+03 0.261 0.305 1.862 5.576 P123 Position #37 CTMT AUX Grouted 7.91E+06 3.11E+05 1.38E+08 9.44E+04 6.60E+02 4.50E+06 2.90E+04 3.96E+03 0.255 0.299 1.825 5.465 P123 Position #38 CTMT AUX Grouted 6.59E+06 2.59E+05 1.15E+08 7.86E+04 5.49E+02 3.74E+06 2.42E+04 3.29E+03 0.213 0.249 1.519 4.550 P123 Position #39 CTMT AUX Grouted 6.09E+06 2.40E+05 1.06E+08 7.27E+04 5.08E+02 3.46E+06 2.23E+04 3.05E+03 0.197 0.230 1.404 4.206 P123 Position #40 CTMT AUX Grouted 6.10E+06 2.40E+05 1.06E+08 7.28E+04 5.08E+02 3.46E+06 2.24E+04 3.05E+03 0.197 0.231 1.406 4.211 P123 Position #41 CTMT AUX Grouted 6.30E+06 2.48E+05 1.10E+08 7.52E+04 5.25E+02 3.58E+06 2.31E+04 3.15E+03 0.203 0.238 1.453 4.352 P123 Position #42 CTMT AUX Grouted 6.92E+06 2.72E+05 1.20E+08 8.25E+04 5.77E+02 3.93E+06 2.54E+04 3.46E+03 0.223 0.262 1.595 4.777 P123 Position #43 CTMT AUX Grouted 6.83E+06 2.69E+05 1.19E+08 8.15E+04 5.69E+02 3.88E+06 2.50E+04 3.41E+03 0.220 0.258 1.574 4.714 P123 Position #44 CTMT AUX Grouted 9.49E+06 3.73E+05 1.65E+08 1.13E+05 7.91E+02 5.39E+06 3.48E+04 4.74E+03 0.306 0.359 2.188 6.551 P123 Position #45 CTMT AUX Grouted 6.67E+06 2.62E+05 1.16E+08 7.96E+04 5.56E+02 3.79E+06 2.45E+04 3.34E+03 0.215 0.252 1.538 4.607 P123 Position #46 CTMT AUX Grouted 5.93E+06 2.33E+05 1.03E+08 7.08E+04 4.95E+02 3.37E+06 2.18E+04 2.97E+03 0.191 0.224 1.368 4.098 P123 Position #47 CTMT AUX Grouted 6.15E+06 2.42E+05 1.07E+08 7.34E+04 5.12E+02 3.49E+06 2.25E+04 3.07E+03 0.198 0.233 1.418 4.246 P123 Position #48 CTMT AUX Grouted 7.26E+06 2.85E+05 1.26E+08 8.66E+04 6.05E+02 4.12E+06 2.66E+04 3.63E+03 0.234 0.274 1.673 5.011 MEASUREMENT ID BETWEEN END STATE
~
=ZIONSOLUTIONSuc-An Er,e,,gyS~ Company
FSS RELEASE RECORD, REV 1 PENETRATIONS SURVEY UNITS 01112, 02112 and 05120
[86]
Auxiliary Building Penetration Measurements (continued)
H-3 (1)
Co-60 (2)
Ni-63 (1)
Sr-90 (1)
Cs-134 (2)
Cs-137 (2)
Eu-152 (2)
Eu-154 (2)
OpSOFPN OpSOFPN OpSOFB OpSOFB (pCi/m2)
(pCi/m2)
(pCi/m2)
(pCi/m2)
(pCi/m2)
(pCi/m2)
(pCi/m2)
(pCi/m2)
CTMTPN Limiting DCGL CTMT/AB DCGL Limiting DCGL P123 Position #49 CTMT AUX Grouted 6.83E+06 2.69E+05 1.19E+08 8.15E+04 5.69E+02 3.88E+06 2.51E+04 3.42E+03 0.220 0.258 1.576 4.719 P123 Position #50 CTMT AUX Grouted 6.54E+06 2.57E+05 1.14E+08 7.81E+04 5.45E+02 3.72E+06 2.40E+04 3.27E+03 0.211 0.247 1.509 4.517 P124 Position #1 CTMT AUX Grouted 8.20E+07 3.23E+06 1.43E+09 9.79E+05 6.84E+03 4.66E+07 3.01E+05 4.10E+04 2.647 3.103 18.915 56.645 P124 Position #2 CTMT AUX Grouted 6.80E+07 2.68E+06 1.18E+09 8.11E+05 5.67E+03 3.86E+07 2.49E+05 3.40E+04 2.194 2.573 15.683 46.966 P124 Position #3 CTMT AUX Grouted 7.10E+07 2.80E+06 1.24E+09 8.48E+05 5.92E+03 4.04E+07 2.61E+05 3.55E+04 2.293 2.688 16.385 49.067 P124 Position #4 CTMT AUX Grouted 7.18E+07 2.83E+06 1.25E+09 8.57E+05 5.99E+03 4.08E+07 2.63E+05 3.59E+04 2.318 2.717 16.564 49.603 P124 Position #5 CTMT AUX Grouted 7.08E+07 2.79E+06 1.23E+09 8.45E+05 5.90E+03 4.02E+07 2.60E+05 3.54E+04 2.286 2.680 16.335 48.917 P124 Position #6 CTMT AUX Grouted 6.72E+07 2.64E+06 1.17E+09 8.02E+05 5.60E+03 3.82E+07 2.46E+05 3.36E+04 2.169 2.543 15.500 46.417 P124 Position #7 CTMT AUX Grouted 5.96E+07 2.35E+06 1.04E+09 7.12E+05 4.97E+03 3.39E+07 2.19E+05 2.98E+04 1.924 2.256 13.752 41.184 P124 Position #8 CTMT AUX Grouted 5.76E+07 2.27E+06 1.00E+09 6.87E+05 4.80E+03 3.27E+07 2.11E+05 2.88E+04 1.859 2.180 13.287 39.789 P124 Position #9 CTMT AUX Grouted 5.79E+07 2.28E+06 1.01E+09 6.91E+05 4.83E+03 3.29E+07 2.12E+05 2.90E+04 1.868 2.190 13.351 39.981 P124 Position #10 CTMT AUX Grouted 5.90E+07 2.32E+06 1.03E+09 7.04E+05 4.92E+03 3.35E+07 2.16E+05 2.95E+04 1.904 2.232 13.606 40.744 P124 Position #11 CTMT AUX Grouted 6.11E+07 2.40E+06 1.06E+09 7.29E+05 5.09E+03 3.47E+07 2.24E+05 3.05E+04 1.971 2.311 14.086 42.182 P124 Position #12 CTMT AUX Grouted 6.22E+07 2.45E+06 1.08E+09 7.42E+05 5.18E+03 3.53E+07 2.28E+05 3.11E+04 2.007 2.352 14.340 42.945 P124 Position #13 CTMT AUX Grouted 6.30E+07 2.48E+06 1.09E+09 7.51E+05 5.25E+03 3.58E+07 2.31E+05 3.15E+04 2.031 2.381 14.517 43.474 P124 Position #14 CTMT AUX Grouted 6.56E+07 2.58E+06 1.14E+09 7.82E+05 5.47E+03 3.73E+07 2.40E+05 3.28E+04 2.116 2.480 15.121 45.282 P124 Position #15 CTMT AUX Grouted 6.30E+07 2.48E+06 1.10E+09 7.52E+05 5.25E+03 3.58E+07 2.31E+05 3.15E+04 2.034 2.384 14.535 43.528 P124 Position #16 CTMT AUX Grouted 5.04E+07 1.98E+06 8.76E+08 6.01E+05 4.20E+03 2.86E+07 1.85E+05 2.52E+04 1.626 1.907 11.624 34.811 P124 Position #17 CTMT AUX Grouted 4.42E+07 1.74E+06 7.69E+08 5.28E+05 3.69E+03 2.51E+07 1.62E+05 2.21E+04 1.427 1.673 10.200 30.546 P124 Position #18 CTMT AUX Grouted 4.10E+07 1.61E+06 7.13E+08 4.89E+05 3.42E+03 2.33E+07 1.50E+05 2.05E+04 1.323 1.551 9.454 28.312 P124 Position #19 CTMT AUX Grouted 3.55E+07 1.40E+06 6.17E+08 4.24E+05 2.96E+03 2.02E+07 1.30E+05 1.78E+04 1.146 1.343 8.189 24.523 P124 Position #20 CTMT AUX Grouted 2.94E+07 1.16E+06 5.11E+08 3.50E+05 2.45E+03 1.67E+07 1.08E+05 1.47E+04 0.947 1.111 6.771 20.276 P124 Position #21 CTMT AUX Grouted 2.45E+07 9.65E+05 4.27E+08 2.93E+05 2.05E+03 1.39E+07 9.00E+04 1.23E+04 0.792 0.928 5.658 16.945 P124 Position #22 CTMT AUX Grouted 1.98E+07 7.77E+05 3.43E+08 2.36E+05 1.65E+03 1.12E+07 7.24E+04 9.88E+03 0.637 0.747 4.555 13.639 P124 Position #23 CTMT AUX Grouted 1.41E+07 5.53E+05 2.45E+08 1.68E+05 1.17E+03 7.99E+06 5.16E+04 7.03E+03 0.454 0.532 3.243 9.712 P124 Position #24 CTMT AUX Grouted 1.03E+07 4.06E+05 1.79E+08 1.23E+05 8.60E+02 5.86E+06 3.78E+04 5.16E+03 0.333 0.390 2.380 7.128 P124 Position #25 CTMT AUX Grouted 8.12E+06 3.19E+05 1.41E+08 9.68E+04 6.76E+02 4.61E+06 2.98E+04 4.06E+03 0.262 0.307 1.871 5.604 P124 Position #26 CTMT AUX Grouted 7.94E+06 3.12E+05 1.38E+08 9.47E+04 6.61E+02 4.51E+06 2.91E+04 3.97E+03 0.256 0.300 1.830 5.480 P124 Position #27 CTMT AUX Grouted 6.81E+06 2.68E+05 1.18E+08 8.13E+04 5.68E+02 3.87E+06 2.50E+04 3.41E+03 0.220 0.258 1.571 4.705 P124 Position #28 CTMT AUX Grouted 6.35E+06 2.50E+05 1.10E+08 7.58E+04 5.29E+02 3.61E+06 2.33E+04 3.18E+03 0.205 0.240 1.465 4.387 P124 Position #29 CTMT AUX Grouted 5.84E+06 2.30E+05 1.02E+08 6.97E+04 4.87E+02 3.32E+06 2.14E+04 2.92E+03 0.189 0.221 1.347 4.034 P124 Position #30 CTMT AUX Grouted 5.60E+06 2.20E+05 9.73E+07 6.68E+04 4.67E+02 3.18E+06 2.05E+04 2.80E+03 0.181 0.212 1.291 3.866 P124 Position #31 CTMT AUX Grouted 5.62E+06 2.21E+05 9.77E+07 6.70E+04 4.68E+02 3.19E+06 2.06E+04 2.81E+03 0.181 0.212 1.295 3.879 P124 Position #32 CTMT AUX Grouted 5.32E+06 2.09E+05 9.25E+07 6.35E+04 4.43E+02 3.02E+06 1.95E+04 2.66E+03 0.172 0.201 1.227 3.674 P124 Position #33 CTMT AUX Grouted 5.28E+06 2.08E+05 9.17E+07 6.30E+04 4.40E+02 3.00E+06 1.93E+04 2.64E+03 0.170 0.200 1.217 3.644 P124 Position #34 CTMT AUX Grouted 5.27E+06 2.07E+05 9.16E+07 6.28E+04 4.39E+02 2.99E+06 1.93E+04 2.63E+03 0.170 0.199 1.214 3.637 P124 Position #35 CTMT AUX Grouted 5.86E+06 2.31E+05 1.02E+08 6.99E+04 4.88E+02 3.33E+06 2.15E+04 2.93E+03 0.189 0.222 1.352 4.047 P124 Position #36 CTMT AUX Grouted 5.28E+06 2.08E+05 9.18E+07 6.30E+04 4.40E+02 3.00E+06 1.94E+04 2.64E+03 0.170 0.200 1.218 3.647 P124 Position #37 CTMT AUX Grouted 4.97E+06 1.96E+05 8.64E+07 5.93E+04 4.14E+02 2.82E+06 1.82E+04 2.49E+03 0.160 0.188 1.146 3.432 P124 Position #38 CTMT AUX Grouted 4.83E+06 1.90E+05 8.39E+07 5.76E+04 4.02E+02 2.74E+06 1.77E+04 2.41E+03 0.156 0.183 1.113 3.334 P124 Position #39 CTMT AUX Grouted 4.85E+06 1.91E+05 8.43E+07 5.78E+04 4.04E+02 2.75E+06 1.78E+04 2.42E+03 0.156 0.183 1.118 3.347 P124 Position #40 CTMT AUX Grouted 4.96E+06 1.95E+05 8.63E+07 5.92E+04 4.14E+02 2.82E+06 1.82E+04 2.48E+03 0.160 0.188 1.145 3.429 P124 Position #41 CTMT AUX Grouted 4.76E+06 1.87E+05 8.28E+07 5.68E+04 3.97E+02 2.71E+06 1.75E+04 2.38E+03 0.154 0.180 1.099 3.290 P124 Position #42 CTMT AUX Grouted 4.80E+06 1.89E+05 8.34E+07 5.73E+04 4.00E+02 2.73E+06 1.76E+04 2.40E+03 0.155 0.182 1.107 3.314 P124 Position #43 CTMT AUX Grouted 5.06E+06 1.99E+05 8.80E+07 6.04E+04 4.22E+02 2.87E+06 1.86E+04 2.53E+03 0.163 0.191 1.167 3.494 P124 Position #44 CTMT AUX Grouted 5.09E+06 2.00E+05 8.85E+07 6.07E+04 4.24E+02 2.89E+06 1.87E+04 2.54E+03 0.164 0.192 1.173 3.514 P124 Position #45 CTMT AUX Grouted 4.80E+06 1.89E+05 8.35E+07 5.73E+04 4.00E+02 2.73E+06 1.76E+04 2.40E+03 0.155 0.182 1.107 3.316 P124 Position #46 CTMT AUX Grouted 4.77E+06 1.87E+05 8.29E+07 5.69E+04 3.97E+02 2.71E+06 1.75E+04 2.38E+03 0.154 0.180 1.099 3.291 P124 Position #47 CTMT AUX Grouted 4.59E+06 1.81E+05 7.98E+07 5.48E+04 3.83E+02 2.61E+06 1.68E+04 2.30E+03 0.148 0.174 1.059 3.171 P124 Position #48 CTMT AUX Grouted 4.46E+06 1.75E+05 7.75E+07 5.32E+04 3.71E+02 2.53E+06 1.63E+04 2.23E+03 0.144 0.169 1.028 3.077 P124 Position #49 CTMT AUX Grouted 4.59E+06 1.80E+05 7.98E+07 5.47E+04 3.82E+02 2.61E+06 1.68E+04 2.29E+03 0.148 0.174 1.058 3.169 P124 Position #50 CTMT AUX Grouted 4.52E+06 1.78E+05 7.85E+07 5.39E+04 3.76E+02 2.57E+06 1.66E+04 2.26E+03 0.146 0.171 1.041 3.118 P037 Position #1 CTMT AUX Grouted 1.56E+07 6.15E+05 2.72E+08 1.86E+05 1.30E+03 8.88E+06 5.73E+04 7.82E+03 0.504 0.591 3.604 10.793 MEASUREMENT ID BETWEEN END STATE
~
=ZIONSOLUTIONSuc-An Er,e,,gyS~ Company
FSS RELEASE RECORD, REV 1 PENETRATIONS SURVEY UNITS 01112, 02112 and 05120
[87]
Auxiliary Building Penetration Measurements (continued)
H-3 (1)
Co-60 (2)
Ni-63 (1)
Sr-90 (1)
Cs-134 (2)
Cs-137 (2)
Eu-152 (2)
Eu-154 (2)
OpSOFPN OpSOFPN OpSOFB OpSOFB (pCi/m2)
(pCi/m2)
(pCi/m2)
(pCi/m2)
(pCi/m2)
(pCi/m2)
(pCi/m2)
(pCi/m2)
CTMTPN Limiting DCGL CTMT/AB DCGL Limiting DCGL P037 Position #2 CTMT AUX Grouted 7.23E+06 2.85E+05 1.26E+08 8.63E+04 6.03E+02 4.11E+06 2.65E+04 3.62E+03 0.233 0.274 1.668 4.995 P037 Position #3 CTMT AUX Grouted 7.69E+06 3.02E+05 1.34E+08 9.17E+04 6.41E+02 4.37E+06 2.82E+04 3.84E+03 0.248 0.291 1.773 5.309 P037 Position #4 CTMT AUX Grouted 4.50E+06 1.77E+05 7.82E+07 5.36E+04 3.75E+02 2.55E+06 1.65E+04 2.25E+03 0.145 0.170 1.037 3.105 P037 Position #5 CTMT AUX Grouted 4.17E+06 1.64E+05 7.25E+07 4.97E+04 3.47E+02 2.37E+06 1.53E+04 2.08E+03 0.134 0.158 0.961 2.878 P037 Position #6 CTMT AUX Grouted 4.29E+06 1.69E+05 7.47E+07 5.12E+04 3.58E+02 2.44E+06 1.57E+04 2.15E+03 0.139 0.162 0.990 2.965 P037 Position #7 CTMT AUX Grouted 4.05E+06 1.59E+05 7.04E+07 4.83E+04 3.38E+02 2.30E+06 1.49E+04 2.03E+03 0.131 0.153 0.934 2.798 P037 Position #8 CTMT AUX Grouted 4.04E+06 1.59E+05 7.03E+07 4.82E+04 3.37E+02 2.30E+06 1.48E+04 2.02E+03 0.130 0.153 0.932 2.791 P037 Position #9 CTMT AUX Grouted 3.90E+06 1.54E+05 6.79E+07 4.66E+04 3.25E+02 2.22E+06 1.43E+04 1.95E+03 0.126 0.148 0.900 2.696 P037 Position #10 CTMT AUX Grouted 3.96E+06 1.56E+05 6.89E+07 4.73E+04 3.30E+02 2.25E+06 1.45E+04 1.98E+03 0.128 0.150 0.913 2.735 P037 Position #11 CTMT AUX Grouted 3.94E+06 1.55E+05 6.86E+07 4.71E+04 3.29E+02 2.24E+06 1.45E+04 1.97E+03 0.127 0.149 0.910 2.724 P037 Position #12 CTMT AUX Grouted 3.95E+06 1.56E+05 6.88E+07 4.72E+04 3.30E+02 2.25E+06 1.45E+04 1.98E+03 0.128 0.150 0.912 2.731 P037 Position #13 CTMT AUX Grouted 4.04E+06 1.59E+05 7.02E+07 4.82E+04 3.36E+02 2.29E+06 1.48E+04 2.02E+03 0.130 0.153 0.931 2.787 P037 Position #14 CTMT AUX Grouted 3.96E+06 1.56E+05 6.89E+07 4.73E+04 3.30E+02 2.25E+06 1.45E+04 1.98E+03 0.128 0.150 0.913 2.735 P037 Position #15 CTMT AUX Grouted 3.82E+06 1.50E+05 6.65E+07 4.56E+04 3.19E+02 2.17E+06 1.40E+04 1.91E+03 0.123 0.145 0.882 2.641 P037 Position #16 CTMT AUX Grouted 3.87E+06 1.52E+05 6.74E+07 4.62E+04 3.23E+02 2.20E+06 1.42E+04 1.94E+03 0.125 0.147 0.893 2.675 P037 Position #17 CTMT AUX Grouted 3.86E+06 1.52E+05 6.72E+07 4.61E+04 3.22E+02 2.20E+06 1.42E+04 1.93E+03 0.125 0.146 0.891 2.668 P037 Position #18 CTMT AUX Grouted 3.72E+06 1.46E+05 6.46E+07 4.44E+04 3.10E+02 2.11E+06 1.36E+04 1.86E+03 0.120 0.141 0.857 2.567 P037 Position #19 CTMT AUX Grouted 3.90E+06 1.53E+05 6.78E+07 4.65E+04 3.25E+02 2.22E+06 1.43E+04 1.95E+03 0.126 0.148 0.899 2.693 P037 Position #20 CTMT AUX Grouted 3.88E+06 1.53E+05 6.75E+07 4.63E+04 3.23E+02 2.20E+06 1.42E+04 1.94E+03 0.125 0.147 0.895 2.679 P037 Position #21 CTMT AUX Grouted 3.79E+06 1.49E+05 6.59E+07 4.52E+04 3.16E+02 2.15E+06 1.39E+04 1.89E+03 0.122 0.143 0.874 2.616 P037 Position #22 CTMT AUX Grouted 3.79E+06 1.49E+05 6.59E+07 4.52E+04 3.16E+02 2.15E+06 1.39E+04 1.89E+03 0.122 0.143 0.874 2.616 P037 Position #23 CTMT AUX Grouted 3.69E+06 1.45E+05 6.41E+07 4.40E+04 3.07E+02 2.09E+06 1.35E+04 1.84E+03 0.119 0.139 0.850 2.546 P037 Position #24 CTMT AUX Grouted 3.49E+06 1.37E+05 6.07E+07 4.16E+04 2.91E+02 1.98E+06 1.28E+04 1.75E+03 0.113 0.132 0.805 2.410 P037 Position #25 CTMT AUX Grouted 3.40E+06 1.34E+05 5.91E+07 4.06E+04 2.83E+02 1.93E+06 1.25E+04 1.70E+03 0.110 0.129 0.784 2.347 P037 Position #26 CTMT AUX Grouted 3.49E+06 1.37E+05 6.08E+07 4.17E+04 2.91E+02 1.99E+06 1.28E+04 1.75E+03 0.113 0.132 0.806 2.413 P037 Position #27 CTMT AUX Grouted 3.40E+06 1.34E+05 5.91E+07 4.06E+04 2.83E+02 1.93E+06 1.25E+04 1.70E+03 0.110 0.129 0.784 2.347 P037 Position #28 CTMT AUX Grouted 3.46E+06 1.36E+05 6.02E+07 4.13E+04 2.89E+02 1.97E+06 1.27E+04 1.73E+03 0.112 0.131 0.799 2.393 P037 Position #29 CTMT AUX Grouted 3.48E+06 1.37E+05 6.05E+07 4.15E+04 2.90E+02 1.98E+06 1.28E+04 1.74E+03 0.112 0.132 0.802 2.403 P037 Position #30 CTMT AUX Grouted 3.46E+06 1.36E+05 6.02E+07 4.13E+04 2.89E+02 1.97E+06 1.27E+04 1.73E+03 0.112 0.131 0.799 2.393 P037 Position #31 CTMT AUX Grouted 3.46E+06 1.36E+05 6.02E+07 4.13E+04 2.89E+02 1.97E+06 1.27E+04 1.73E+03 0.112 0.131 0.799 2.393 P037 Position #32 CTMT AUX Grouted 3.61E+06 1.42E+05 6.27E+07 4.30E+04 3.01E+02 2.05E+06 1.32E+04 1.80E+03 0.116 0.136 0.832 2.490 P037 Position #33 CTMT AUX Grouted 3.58E+06 1.41E+05 6.23E+07 4.27E+04 2.98E+02 2.03E+06 1.31E+04 1.79E+03 0.116 0.135 0.826 2.473 P037 Position #34 CTMT AUX Grouted 3.57E+06 1.40E+05 6.20E+07 4.25E+04 2.97E+02 2.03E+06 1.31E+04 1.78E+03 0.115 0.135 0.822 2.462 P037 Position #35 CTMT AUX Grouted 3.51E+06 1.38E+05 6.11E+07 4.19E+04 2.93E+02 2.00E+06 1.29E+04 1.76E+03 0.113 0.133 0.811 2.427 P037 Position #36 CTMT AUX Grouted 3.58E+06 1.41E+05 6.22E+07 4.27E+04 2.98E+02 2.03E+06 1.31E+04 1.79E+03 0.115 0.135 0.825 2.469 P037 Position #37 CTMT AUX Grouted 3.63E+06 1.43E+05 6.31E+07 4.33E+04 3.02E+02 2.06E+06 1.33E+04 1.81E+03 0.117 0.137 0.836 2.504 P037 Position #38 CTMT AUX Grouted 3.50E+06 1.38E+05 6.09E+07 4.18E+04 2.92E+02 1.99E+06 1.29E+04 1.75E+03 0.113 0.133 0.808 2.420 P037 Position #39 CTMT AUX Grouted 3.51E+06 1.38E+05 6.10E+07 4.19E+04 2.93E+02 1.99E+06 1.29E+04 1.76E+03 0.113 0.133 0.809 2.424 P037 Position #40 CTMT AUX Grouted 3.52E+06 1.38E+05 6.12E+07 4.20E+04 2.93E+02 2.00E+06 1.29E+04 1.76E+03 0.114 0.133 0.812 2.431 P037 Position #41 CTMT AUX Grouted 3.59E+06 1.41E+05 6.24E+07 4.28E+04 2.99E+02 2.04E+06 1.32E+04 1.79E+03 0.116 0.136 0.827 2.476 P037 Position #42 CTMT AUX Grouted 3.66E+06 1.44E+05 6.36E+07 4.36E+04 3.05E+02 2.08E+06 1.34E+04 1.83E+03 0.118 0.138 0.843 2.525 P037 Position #43 CTMT AUX Grouted 3.69E+06 1.45E+05 6.41E+07 4.40E+04 3.07E+02 2.09E+06 1.35E+04 1.84E+03 0.119 0.139 0.850 2.546 P037 Position #44 CTMT AUX Grouted 3.75E+06 1.48E+05 6.53E+07 4.48E+04 3.13E+02 2.13E+06 1.38E+04 1.88E+03 0.121 0.142 0.865 2.592 P037 Position #45 CTMT AUX Grouted 3.73E+06 1.47E+05 6.49E+07 4.45E+04 3.11E+02 2.12E+06 1.37E+04 1.87E+03 0.120 0.141 0.861 2.578 P037 Position #46 CTMT AUX Grouted 3.84E+06 1.51E+05 6.68E+07 4.59E+04 3.20E+02 2.18E+06 1.41E+04 1.92E+03 0.124 0.145 0.886 2.654 P037 Position #47 CTMT AUX Grouted 3.82E+06 1.50E+05 6.65E+07 4.56E+04 3.19E+02 2.17E+06 1.40E+04 1.91E+03 0.123 0.145 0.882 2.641 P037 Position #48 CTMT AUX Grouted 3.97E+06 1.56E+05 6.89E+07 4.73E+04 3.30E+02 2.25E+06 1.45E+04 1.98E+03 0.128 0.150 0.914 2.738 P037 Position #49 CTMT AUX Grouted 4.04E+06 1.59E+05 7.03E+07 4.82E+04 3.37E+02 2.30E+06 1.48E+04 2.02E+03 0.130 0.153 0.932 2.791 P037 Position #50 CTMT AUX Grouted 4.07E+06 1.60E+05 7.08E+07 4.86E+04 3.39E+02 2.31E+06 1.49E+04 2.04E+03 0.131 0.154 0.939 2.812 P036 Position #1 CTMT AUX Grouted 2.37E+07 9.33E+05 4.12E+08 2.83E+05 1.98E+03 1.35E+07 8.70E+04 1.19E+04 0.765 0.897 5.470 16.381 P036 Position #2 CTMT AUX Grouted 8.09E+06 3.18E+05 1.41E+08 9.66E+04 6.74E+02 4.60E+06 2.97E+04 4.05E+03 0.261 0.306 1.866 5.588 P036 Position #3 CTMT AUX Grouted 4.74E+06 1.87E+05 8.25E+07 5.66E+04 3.95E+02 2.70E+06 1.74E+04 2.37E+03 0.153 0.179 1.094 3.276 P036 Position #4 CTMT AUX Grouted 4.36E+06 1.72E+05 7.58E+07 5.20E+04 3.63E+02 2.48E+06 1.60E+04 2.18E+03 0.141 0.165 1.005 3.011 MEASUREMENT ID BETWEEN END STATE
~
=ZIONSOLUTIONSuc-An Er,e,,gyS~ Company
FSS RELEASE RECORD, REV 1 PENETRATIONS SURVEY UNITS 01112, 02112 and 05120
[88]
Auxiliary Building Penetration Measurements (continued)
H-3 (1)
Co-60 (2)
Ni-63 (1)
Sr-90 (1)
Cs-134 (2)
Cs-137 (2)
Eu-152 (2)
Eu-154 (2)
OpSOFPN OpSOFPN OpSOFB OpSOFB (pCi/m2)
(pCi/m2)
(pCi/m2)
(pCi/m2)
(pCi/m2)
(pCi/m2)
(pCi/m2)
(pCi/m2)
CTMTPN Limiting DCGL CTMT/AB DCGL Limiting DCGL P036 Position #5 CTMT AUX Grouted 4.30E+06 1.69E+05 7.48E+07 5.14E+04 3.59E+02 2.45E+06 1.58E+04 2.15E+03 0.139 0.163 0.993 2.972 P036 Position #6 CTMT AUX Grouted 4.17E+06 1.64E+05 7.26E+07 4.98E+04 3.48E+02 2.37E+06 1.53E+04 2.09E+03 0.135 0.158 0.962 2.881 P036 Position #7 CTMT AUX Grouted 3.93E+06 1.55E+05 6.83E+07 4.69E+04 3.28E+02 2.23E+06 1.44E+04 1.97E+03 0.127 0.149 0.906 2.714 P036 Position #8 CTMT AUX Grouted 3.94E+06 1.55E+05 6.86E+07 4.71E+04 3.29E+02 2.24E+06 1.45E+04 1.97E+03 0.127 0.149 0.910 2.724 P036 Position #9 CTMT AUX Grouted 3.83E+06 1.51E+05 6.67E+07 4.57E+04 3.20E+02 2.18E+06 1.41E+04 1.92E+03 0.124 0.145 0.884 2.647 P036 Position #10 CTMT AUX Grouted 3.86E+06 1.52E+05 6.72E+07 4.61E+04 3.22E+02 2.20E+06 1.42E+04 1.93E+03 0.125 0.146 0.891 2.668 P036 Position #11 CTMT AUX Grouted 3.84E+06 1.51E+05 6.68E+07 4.59E+04 3.20E+02 2.18E+06 1.41E+04 1.92E+03 0.124 0.145 0.886 2.654 P036 Position #12 CTMT AUX Grouted 3.79E+06 1.49E+05 6.60E+07 4.53E+04 3.16E+02 2.16E+06 1.39E+04 1.90E+03 0.122 0.143 0.875 2.620 P036 Position #13 CTMT AUX Grouted 3.72E+06 1.46E+05 6.46E+07 4.44E+04 3.10E+02 2.11E+06 1.36E+04 1.86E+03 0.120 0.141 0.857 2.567 P036 Position #14 CTMT AUX Grouted 3.74E+06 1.47E+05 6.51E+07 4.47E+04 3.12E+02 2.13E+06 1.37E+04 1.87E+03 0.121 0.142 0.863 2.585 P036 Position #15 CTMT AUX Grouted 3.82E+06 1.50E+05 6.65E+07 4.56E+04 3.19E+02 2.17E+06 1.40E+04 1.91E+03 0.123 0.145 0.882 2.641 P036 Position #16 CTMT AUX Grouted 3.70E+06 1.45E+05 6.43E+07 4.41E+04 3.08E+02 2.10E+06 1.36E+04 1.85E+03 0.119 0.140 0.853 2.553 P036 Position #17 CTMT AUX Grouted 3.77E+06 1.48E+05 6.55E+07 4.50E+04 3.14E+02 2.14E+06 1.38E+04 1.88E+03 0.122 0.143 0.869 2.602 P036 Position #18 CTMT AUX Grouted 3.71E+06 1.46E+05 6.45E+07 4.43E+04 3.09E+02 2.11E+06 1.36E+04 1.86E+03 0.120 0.140 0.856 2.564 P036 Position #19 CTMT AUX Grouted 3.66E+06 1.44E+05 6.37E+07 4.37E+04 3.05E+02 2.08E+06 1.34E+04 1.83E+03 0.118 0.139 0.844 2.529 P036 Position #20 CTMT AUX Grouted 3.61E+06 1.42E+05 6.27E+07 4.30E+04 3.01E+02 2.05E+06 1.32E+04 1.80E+03 0.116 0.136 0.832 2.490 P036 Position #21 CTMT AUX Grouted 3.35E+06 1.32E+05 5.83E+07 4.00E+04 2.79E+02 1.91E+06 1.23E+04 1.68E+03 0.108 0.127 0.773 2.316 P036 Position #22 CTMT AUX Grouted 3.38E+06 1.33E+05 5.87E+07 4.03E+04 2.82E+02 1.92E+06 1.24E+04 1.69E+03 0.109 0.128 0.779 2.333 P036 Position #23 CTMT AUX Grouted 3.35E+06 1.32E+05 5.83E+07 4.00E+04 2.79E+02 1.91E+06 1.23E+04 1.68E+03 0.108 0.127 0.773 2.316 P036 Position #24 CTMT AUX Grouted 3.19E+06 1.26E+05 5.55E+07 3.81E+04 2.66E+02 1.81E+06 1.17E+04 1.60E+03 0.103 0.121 0.736 2.204 P036 Position #25 CTMT AUX Grouted 3.26E+06 1.28E+05 5.66E+07 3.89E+04 2.71E+02 1.85E+06 1.19E+04 1.63E+03 0.105 0.123 0.751 2.249 P036 Position #26 CTMT AUX Grouted 3.24E+06 1.27E+05 5.63E+07 3.86E+04 2.70E+02 1.84E+06 1.19E+04 1.62E+03 0.104 0.122 0.746 2.235 P036 Position #27 CTMT AUX Grouted 3.33E+06 1.31E+05 5.80E+07 3.98E+04 2.78E+02 1.89E+06 1.22E+04 1.67E+03 0.108 0.126 0.769 2.302 P036 Position #28 CTMT AUX Grouted 3.40E+06 1.34E+05 5.92E+07 4.06E+04 2.84E+02 1.93E+06 1.25E+04 1.70E+03 0.110 0.129 0.785 2.351 P036 Position #29 CTMT AUX Grouted 3.34E+06 1.31E+05 5.80E+07 3.98E+04 2.78E+02 1.90E+06 1.22E+04 1.67E+03 0.108 0.126 0.770 2.305 P036 Position #30 CTMT AUX Grouted 3.40E+06 1.34E+05 5.92E+07 4.06E+04 2.84E+02 1.93E+06 1.25E+04 1.70E+03 0.110 0.129 0.785 2.351 P036 Position #31 CTMT AUX Grouted 3.38E+06 1.33E+05 5.88E+07 4.04E+04 2.82E+02 1.92E+06 1.24E+04 1.69E+03 0.109 0.128 0.780 2.337 P036 Position #32 CTMT AUX Grouted 3.46E+06 1.36E+05 6.02E+07 4.13E+04 2.89E+02 1.97E+06 1.27E+04 1.73E+03 0.112 0.131 0.799 2.393 P036 Position #33 CTMT AUX Grouted 3.48E+06 1.37E+05 6.06E+07 4.16E+04 2.90E+02 1.98E+06 1.28E+04 1.74E+03 0.112 0.132 0.804 2.406 P036 Position #34 CTMT AUX Grouted 3.44E+06 1.35E+05 5.98E+07 4.10E+04 2.87E+02 1.95E+06 1.26E+04 1.72E+03 0.111 0.130 0.793 2.375 P036 Position #35 CTMT AUX Grouted 3.49E+06 1.37E+05 6.08E+07 4.17E+04 2.91E+02 1.99E+06 1.28E+04 1.75E+03 0.113 0.132 0.806 2.413 P036 Position #36 CTMT AUX Grouted 3.51E+06 1.38E+05 6.10E+07 4.19E+04 2.93E+02 1.99E+06 1.29E+04 1.76E+03 0.113 0.133 0.809 2.424 P036 Position #37 CTMT AUX Grouted 3.47E+06 1.37E+05 6.04E+07 4.15E+04 2.90E+02 1.97E+06 1.27E+04 1.74E+03 0.112 0.131 0.801 2.400 P036 Position #38 CTMT AUX Grouted 3.45E+06 1.36E+05 6.01E+07 4.12E+04 2.88E+02 1.96E+06 1.27E+04 1.73E+03 0.111 0.131 0.797 2.386 P036 Position #39 CTMT AUX Grouted 3.39E+06 1.34E+05 5.90E+07 4.05E+04 2.83E+02 1.93E+06 1.24E+04 1.70E+03 0.110 0.128 0.783 2.344 P036 Position #40 CTMT AUX Grouted 3.45E+06 1.36E+05 6.00E+07 4.12E+04 2.87E+02 1.96E+06 1.26E+04 1.72E+03 0.111 0.130 0.795 2.382 P036 Position #41 CTMT AUX Grouted 3.58E+06 1.41E+05 6.22E+07 4.27E+04 2.98E+02 2.03E+06 1.31E+04 1.79E+03 0.115 0.135 0.825 2.469 P036 Position #42 CTMT AUX Grouted 3.50E+06 1.38E+05 6.09E+07 4.18E+04 2.92E+02 1.99E+06 1.29E+04 1.75E+03 0.113 0.133 0.808 2.420 P036 Position #43 CTMT AUX Grouted 3.52E+06 1.38E+05 6.12E+07 4.20E+04 2.93E+02 2.00E+06 1.29E+04 1.76E+03 0.114 0.133 0.812 2.431 P036 Position #44 CTMT AUX Grouted 3.68E+06 1.45E+05 6.40E+07 4.39E+04 3.07E+02 2.09E+06 1.35E+04 1.84E+03 0.119 0.139 0.849 2.543 P036 Position #45 CTMT AUX Grouted 3.65E+06 1.44E+05 6.35E+07 4.36E+04 3.04E+02 2.07E+06 1.34E+04 1.83E+03 0.118 0.138 0.842 2.522 P036 Position #46 CTMT AUX Grouted 3.92E+06 1.54E+05 6.82E+07 4.68E+04 3.27E+02 2.23E+06 1.44E+04 1.96E+03 0.126 0.148 0.904 2.707 P036 Position #47 CTMT AUX Grouted 4.17E+06 1.64E+05 7.25E+07 4.97E+04 3.47E+02 2.37E+06 1.53E+04 2.08E+03 0.134 0.158 0.961 2.878 P036 Position #48 CTMT AUX Grouted 4.70E+06 1.85E+05 8.17E+07 5.61E+04 3.92E+02 2.67E+06 1.72E+04 2.35E+03 0.152 0.178 1.084 3.245 P036 Position #49 CTMT AUX Grouted 4.20E+06 1.65E+05 7.31E+07 5.01E+04 3.50E+02 2.39E+06 1.54E+04 2.10E+03 0.136 0.159 0.969 2.902 P036 Position #50 CTMT AUX Grouted 3.76E+06 1.48E+05 6.54E+07 4.49E+04 3.14E+02 2.14E+06 1.38E+04 1.88E+03 0.121 0.142 0.868 2.599 P035 Position #1 CTMT AUX Grouted 1.79E+07 7.04E+05 3.11E+08 2.14E+05 1.49E+03 1.02E+07 6.57E+04 8.95E+03 0.578 0.677 4.129 12.364 P035 Position #2 CTMT AUX Grouted 6.47E+06 2.55E+05 1.13E+08 7.72E+04 5.40E+02 3.68E+06 2.37E+04 3.24E+03 0.209 0.245 1.493 4.471 P035 Position #3 CTMT AUX Grouted 4.72E+06 1.86E+05 8.21E+07 5.64E+04 3.94E+02 2.68E+06 1.73E+04 2.36E+03 0.152 0.179 1.089 3.262 P035 Position #4 CTMT AUX Grouted 4.39E+06 1.73E+05 7.64E+07 5.24E+04 3.66E+02 2.50E+06 1.61E+04 2.20E+03 0.142 0.166 1.014 3.035 P035 Position #5 CTMT AUX Grouted 4.27E+06 1.68E+05 7.43E+07 5.10E+04 3.56E+02 2.43E+06 1.57E+04 2.14E+03 0.138 0.162 0.986 2.951 P035 Position #6 CTMT AUX Grouted 4.13E+06 1.62E+05 7.18E+07 4.92E+04 3.44E+02 2.34E+06 1.51E+04 2.06E+03 0.133 0.156 0.952 2.850 P035 Position #7 CTMT AUX Grouted 4.01E+06 1.58E+05 6.96E+07 4.78E+04 3.34E+02 2.28E+06 1.47E+04 2.00E+03 0.129 0.152 0.924 2.766 MEASUREMENT ID BETWEEN END STATE
~
=ZIONSOLUTIONSuc-An Er,e,,gyS~ Company
FSS RELEASE RECORD, REV 1 PENETRATIONS SURVEY UNITS 01112, 02112 and 05120
[89]
Auxiliary Building Penetration Measurements (continued)
H-3 (1)
Co-60 (2)
Ni-63 (1)
Sr-90 (1)
Cs-134 (2)
Cs-137 (2)
Eu-152 (2)
Eu-154 (2)
OpSOFPN OpSOFPN OpSOFB OpSOFB (pCi/m2)
(pCi/m2)
(pCi/m2)
(pCi/m2)
(pCi/m2)
(pCi/m2)
(pCi/m2)
(pCi/m2)
CTMTPN Limiting DCGL CTMT/AB DCGL Limiting DCGL P035 Position #8 CTMT AUX Grouted 4.14E+06 1.63E+05 7.19E+07 4.94E+04 3.45E+02 2.35E+06 1.52E+04 2.07E+03 0.133 0.157 0.954 2.857 P035 Position #9 CTMT AUX Grouted 4.08E+06 1.60E+05 7.09E+07 4.86E+04 3.40E+02 2.32E+06 1.49E+04 2.04E+03 0.132 0.154 0.940 2.815 P035 Position #10 CTMT AUX Grouted 3.90E+06 1.53E+05 6.78E+07 4.65E+04 3.25E+02 2.22E+06 1.43E+04 1.95E+03 0.126 0.148 0.899 2.693 P035 Position #11 CTMT AUX Grouted 3.93E+06 1.55E+05 6.84E+07 4.69E+04 3.28E+02 2.24E+06 1.44E+04 1.97E+03 0.127 0.149 0.907 2.717 P035 Position #12 CTMT AUX Grouted 4.04E+06 1.59E+05 7.02E+07 4.82E+04 3.36E+02 2.29E+06 1.48E+04 2.02E+03 0.130 0.153 0.931 2.787 P035 Position #13 CTMT AUX Grouted 3.98E+06 1.56E+05 6.91E+07 4.74E+04 3.31E+02 2.26E+06 1.46E+04 1.99E+03 0.128 0.150 0.917 2.745 P035 Position #14 CTMT AUX Grouted 4.02E+06 1.58E+05 6.98E+07 4.79E+04 3.35E+02 2.28E+06 1.47E+04 2.01E+03 0.130 0.152 0.926 2.773 P035 Position #15 CTMT AUX Grouted 4.07E+06 1.60E+05 7.08E+07 4.86E+04 3.39E+02 2.31E+06 1.49E+04 2.04E+03 0.131 0.154 0.939 2.812 P035 Position #16 CTMT AUX Grouted 3.99E+06 1.57E+05 6.94E+07 4.76E+04 3.33E+02 2.27E+06 1.46E+04 2.00E+03 0.129 0.151 0.920 2.756 P035 Position #17 CTMT AUX Grouted 3.93E+06 1.55E+05 6.84E+07 4.69E+04 3.28E+02 2.24E+06 1.44E+04 1.97E+03 0.127 0.149 0.907 2.717 P035 Position #18 CTMT AUX Grouted 3.88E+06 1.53E+05 6.75E+07 4.63E+04 3.23E+02 2.20E+06 1.42E+04 1.94E+03 0.125 0.147 0.895 2.679 P035 Position #19 CTMT AUX Grouted 3.82E+06 1.50E+05 6.64E+07 4.56E+04 3.18E+02 2.17E+06 1.40E+04 1.91E+03 0.123 0.144 0.881 2.637 P035 Position #20 CTMT AUX Grouted 3.65E+06 1.44E+05 6.35E+07 4.36E+04 3.04E+02 2.07E+06 1.34E+04 1.83E+03 0.118 0.138 0.842 2.522 P035 Position #21 CTMT AUX Grouted 3.54E+06 1.39E+05 6.16E+07 4.22E+04 2.95E+02 2.01E+06 1.30E+04 1.77E+03 0.114 0.134 0.816 2.445 P035 Position #22 CTMT AUX Grouted 3.57E+06 1.40E+05 6.21E+07 4.26E+04 2.98E+02 2.03E+06 1.31E+04 1.79E+03 0.115 0.135 0.823 2.466 P035 Position #23 CTMT AUX Grouted 3.53E+06 1.39E+05 6.13E+07 4.21E+04 2.94E+02 2.00E+06 1.29E+04 1.76E+03 0.114 0.133 0.813 2.434 P035 Position #24 CTMT AUX Grouted 3.32E+06 1.31E+05 5.78E+07 3.96E+04 2.77E+02 1.89E+06 1.22E+04 1.66E+03 0.107 0.126 0.766 2.295 P035 Position #25 CTMT AUX Grouted 3.45E+06 1.36E+05 6.00E+07 4.12E+04 2.87E+02 1.96E+06 1.26E+04 1.72E+03 0.111 0.130 0.795 2.382 P035 Position #26 CTMT AUX Grouted 3.42E+06 1.34E+05 5.94E+07 4.08E+04 2.85E+02 1.94E+06 1.25E+04 1.71E+03 0.110 0.129 0.788 2.361 P035 Position #27 CTMT AUX Grouted 3.33E+06 1.31E+05 5.80E+07 3.98E+04 2.78E+02 1.89E+06 1.22E+04 1.67E+03 0.108 0.126 0.769 2.302 P035 Position #28 CTMT AUX Grouted 3.45E+06 1.36E+05 6.01E+07 4.12E+04 2.88E+02 1.96E+06 1.27E+04 1.73E+03 0.111 0.131 0.797 2.386 P035 Position #29 CTMT AUX Grouted 3.44E+06 1.35E+05 5.98E+07 4.10E+04 2.87E+02 1.95E+06 1.26E+04 1.72E+03 0.111 0.130 0.793 2.375 P035 Position #30 CTMT AUX Grouted 3.43E+06 1.35E+05 5.97E+07 4.10E+04 2.86E+02 1.95E+06 1.26E+04 1.72E+03 0.111 0.130 0.792 2.372 P035 Position #31 CTMT AUX Grouted 3.52E+06 1.38E+05 6.12E+07 4.20E+04 2.93E+02 2.00E+06 1.29E+04 1.76E+03 0.114 0.133 0.812 2.431 P035 Position #32 CTMT AUX Grouted 3.56E+06 1.40E+05 6.18E+07 4.24E+04 2.96E+02 2.02E+06 1.30E+04 1.78E+03 0.115 0.135 0.820 2.455 P035 Position #33 CTMT AUX Grouted 3.56E+06 1.40E+05 6.18E+07 4.24E+04 2.96E+02 2.02E+06 1.30E+04 1.78E+03 0.115 0.135 0.820 2.455 P035 Position #34 CTMT AUX Grouted 3.73E+06 1.47E+05 6.49E+07 4.45E+04 3.11E+02 2.12E+06 1.37E+04 1.87E+03 0.120 0.141 0.861 2.578 P035 Position #35 CTMT AUX Grouted 3.74E+06 1.47E+05 6.51E+07 4.47E+04 3.12E+02 2.13E+06 1.37E+04 1.87E+03 0.121 0.142 0.863 2.585 P035 Position #36 CTMT AUX Grouted 3.87E+06 1.52E+05 6.74E+07 4.62E+04 3.23E+02 2.20E+06 1.42E+04 1.94E+03 0.125 0.147 0.893 2.675 P035 Position #37 CTMT AUX Grouted 3.84E+06 1.51E+05 6.67E+07 4.58E+04 3.20E+02 2.18E+06 1.41E+04 1.92E+03 0.124 0.145 0.885 2.651 P035 Position #38 CTMT AUX Grouted 3.87E+06 1.52E+05 6.73E+07 4.62E+04 3.22E+02 2.20E+06 1.42E+04 1.93E+03 0.125 0.146 0.892 2.672 P035 Position #39 CTMT AUX Grouted 3.81E+06 1.50E+05 6.63E+07 4.55E+04 3.18E+02 2.17E+06 1.40E+04 1.91E+03 0.123 0.144 0.879 2.634 P035 Position #40 CTMT AUX Grouted 3.79E+06 1.49E+05 6.59E+07 4.52E+04 3.16E+02 2.15E+06 1.39E+04 1.89E+03 0.122 0.143 0.874 2.616 P035 Position #41 CTMT AUX Grouted 3.86E+06 1.52E+05 6.71E+07 4.60E+04 3.22E+02 2.19E+06 1.42E+04 1.93E+03 0.125 0.146 0.890 2.665 P035 Position #42 CTMT AUX Grouted 3.99E+06 1.57E+05 6.93E+07 4.76E+04 3.32E+02 2.26E+06 1.46E+04 1.99E+03 0.129 0.151 0.919 2.752 P035 Position #43 CTMT AUX Grouted 3.90E+06 1.54E+05 6.79E+07 4.66E+04 3.25E+02 2.22E+06 1.43E+04 1.95E+03 0.126 0.148 0.900 2.696 P035 Position #44 CTMT AUX Grouted 4.08E+06 1.60E+05 7.09E+07 4.86E+04 3.40E+02 2.32E+06 1.49E+04 2.04E+03 0.132 0.154 0.940 2.815 P035 Position #45 CTMT AUX Grouted 4.22E+06 1.66E+05 7.34E+07 5.04E+04 3.52E+02 2.40E+06 1.55E+04 2.11E+03 0.136 0.160 0.974 2.916 P035 Position #46 CTMT AUX Grouted 4.23E+06 1.66E+05 7.35E+07 5.04E+04 3.52E+02 2.40E+06 1.55E+04 2.11E+03 0.136 0.160 0.975 2.920 P035 Position #47 CTMT AUX Grouted 4.32E+06 1.70E+05 7.52E+07 5.16E+04 3.60E+02 2.46E+06 1.59E+04 2.16E+03 0.140 0.164 0.997 2.986 P035 Position #48 CTMT AUX Grouted 4.40E+06 1.73E+05 7.65E+07 5.25E+04 3.67E+02 2.50E+06 1.61E+04 2.20E+03 0.142 0.166 1.015 3.039 P035 Position #49 CTMT AUX Grouted 4.55E+06 1.79E+05 7.91E+07 5.43E+04 3.79E+02 2.58E+06 1.67E+04 2.27E+03 0.147 0.172 1.049 3.140 P035 Position #50 CTMT AUX Grouted 4.91E+06 1.93E+05 8.54E+07 5.86E+04 4.09E+02 2.79E+06 1.80E+04 2.46E+03 0.158 0.186 1.132 3.391 P035 Position #51 CTMT AUX Grouted 4.40E+06 1.73E+05 7.65E+07 5.25E+04 3.67E+02 2.50E+06 1.61E+04 2.20E+03 0.142 0.166 1.015 3.039 P003 Position #1 CTMT AUX Removed 1.61E+06 6.33E+04 2.80E+07 1.92E+04 1.34E+02 9.15E+05 5.90E+03 8.05E+02 0.052 0.061 0.371 1.112 P003 Position #2 CTMT AUX Removed 1.91E+06 7.53E+04 3.33E+07 2.28E+04 1.59E+02 1.09E+06 7.02E+03 9.57E+02 0.062 0.072 0.441 1.321 P003 Position #3 CTMT AUX Removed 7.45E+06 2.93E+05 1.30E+08 8.89E+04 6.21E+02 4.23E+06 2.73E+04 3.73E+03 0.240 0.282 1.718 5.146 P050 Position #1 CTMT AUX Removed 4.04E+06 1.59E+05 7.02E+07 4.82E+04 3.37E+02 2.30E+06 1.48E+04 2.02E+03 0.130 0.153 0.931 2.789 P050 Position #2 CTMT AUX Removed 5.25E+06 2.07E+05 9.13E+07 6.26E+04 4.38E+02 2.98E+06 1.93E+04 2.63E+03 0.169 0.199 1.211 3.626 P050 Position #3 CTMT AUX Removed 6.17E+06 2.43E+05 1.07E+08 7.36E+04 5.14E+02 3.50E+06 2.26E+04 3.08E+03 0.199 0.233 1.422 4.259 P087 Position #1 CTMT AUX Removed 7.20E+06 2.83E+05 1.25E+08 8.59E+04 6.00E+02 4.09E+06 2.64E+04 3.60E+03 0.232 0.272 1.660 4.970 P087 Position #2 CTMT AUX Removed 9.19E+06 3.62E+05 1.60E+08 1.10E+05 7.66E+02 5.22E+06 3.37E+04 4.60E+03 0.297 0.348 2.120 6.350 P087 Position #3 CTMT AUX Removed 1.46E+07 5.74E+05 2.54E+08 1.74E+05 1.22E+03 8.29E+06 5.35E+04 7.29E+03 0.471 0.552 3.363 10.071 MEASUREMENT ID BETWEEN END STATE
~
=ZIONSOLUTIONSuc-An Er,e,,gyS~ Company
FSS RELEASE RECORD, REV 1 PENETRATIONS SURVEY UNITS 01112, 02112 and 05120
[90]
Auxiliary Building Penetration Measurements (continued)
H-3 (1)
Co-60 (2)
Ni-63 (1)
Sr-90 (1)
Cs-134 (2)
Cs-137 (2)
Eu-152 (2)
Eu-154 (2)
OpSOFPN OpSOFPN OpSOFB OpSOFB (pCi/m2)
(pCi/m2)
(pCi/m2)
(pCi/m2)
(pCi/m2)
(pCi/m2)
(pCi/m2)
(pCi/m2)
CTMTPN Limiting DCGL CTMT/AB DCGL Limiting DCGL P064 Position #1 CTMT AUX Removed 5.56E+06 2.19E+05 9.67E+07 6.64E+04 4.64E+02 3.16E+06 2.04E+04 2.78E+03 0.180 0.210 1.283 3.842 P064 Position #2 CTMT AUX Removed 6.07E+06 2.39E+05 1.06E+08 7.25E+04 5.06E+02 3.45E+06 2.23E+04 3.04E+03 0.196 0.230 1.401 4.194 P064 Position #3 CTMT AUX Removed 7.94E+06 3.12E+05 1.38E+08 9.47E+04 6.62E+02 4.51E+06 2.91E+04 3.97E+03 0.256 0.300 1.830 5.481 P018 By Direct Scan CTMT AUX Removed 1.06E+07 4.17E+05 1.84E+08 1.26E+05 8.83E+02 6.02E+06 3.89E+04 5.30E+03 0.342 0.401 2.444 7.319 P090 By Direct Scan CTMT AUX Removed 9.23E+06 3.63E+05 1.61E+08 1.10E+05 7.70E+02 5.25E+06 3.39E+04 4.62E+03 0.298 0.349 2.129 6.376 P020 By Direct Scan CTMT AUX Removed 2.73E+07 1.07E+06 4.75E+08 3.26E+05 2.28E+03 1.55E+07 1.00E+05 1.37E+04 0.882 1.034 6.301 18.870 P021 By Direct Scan CTMT AUX Removed 4.57E+07 1.80E+06 7.95E+08 5.45E+05 3.81E+03 2.60E+07 1.68E+05 2.29E+04 1.475 1.729 10.541 31.568 P067 By Direct Scan CTMT AUX Removed 3.36E+06 1.32E+05 5.84E+07 4.00E+04 2.80E+02 1.91E+06 1.23E+04 1.68E+03 0.108 0.127 0.774 2.317 P073 By Direct Scan CTMT AUX Removed 5.78E+06 2.27E+05 1.00E+08 6.89E+04 4.81E+02 3.28E+06 2.12E+04 2.89E+03 0.186 0.218 1.332 3.989 P105 By Direct Scan CTMT AUX Removed 1.76E+06 6.93E+04 3.06E+07 2.10E+04 1.47E+02 1.00E+06 6.46E+03 8.81E+02 0.057 0.067 0.406 1.217 P068 By Direct Scan CTMT AUX Removed 1.09E+05 4.29E+03 1.89E+06 1.30E+03 9.08E+00 6.19E+04 4.00E+02 5.45E+01 0.004 0.004 0.025 0.075 P070 By Direct Scan CTMT AUX Removed 2.79E+05 1.10E+04 4.85E+06 3.33E+03 2.33E+01 1.59E+05 1.02E+03 1.40E+02 0.009 0.011 0.064 0.193 P069 By Direct Scan CTMT AUX Removed 1.31E+05 5.17E+03 2.28E+06 1.57E+03 1.09E+01 7.46E+04 4.82E+02 6.57E+01 0.004 0.005 0.030 0.091 P066 By Direct Scan CTMT AUX Removed 1.17E+05 4.61E+03 2.04E+06 1.40E+03 9.77E+00 6.66E+04 4.30E+02 5.86E+01 0.004 0.004 0.027 0.081 P017 By Direct Scan CTMT AUX Removed 1.27E+05 5.01E+03 2.21E+06 1.52E+03 1.06E+01 7.23E+04 4.67E+02 6.36E+01 0.004 0.005 0.029 0.088 P103 Position #1 CTMT AUX Removed 9.35E+06 3.68E+05 1.63E+08 1.12E+05 7.80E+02 5.31E+06 3.43E+04 4.68E+03 0.302 0.354 2.157 6.459 P103 Position #2 CTMT AUX Removed 3.80E+06 1.49E+05 6.60E+07 4.53E+04 3.16E+02 2.16E+06 1.39E+04 1.90E+03 0.123 0.144 0.876 2.622 P103 Position #3 CTMT AUX Removed 2.58E+06 1.01E+05 4.49E+07 3.08E+04 2.15E+02 1.47E+06 9.46E+03 1.29E+03 0.083 0.098 0.595 1.782 P103 Position #4 CTMT AUX Removed 2.19E+06 8.63E+04 3.81E+07 2.62E+04 1.83E+02 1.25E+06 8.04E+03 1.10E+03 0.071 0.083 0.506 1.514 P103 Position #5 CTMT AUX Removed 2.54E+06 1.00E+05 4.42E+07 3.03E+04 2.12E+02 1.44E+06 9.32E+03 1.27E+03 0.082 0.096 0.586 1.755 P056 Position #1 CTMT AUX Removed 1.17E+07 4.61E+05 2.04E+08 1.40E+05 9.76E+02 6.65E+06 4.29E+04 5.86E+03 0.378 0.443 2.701 8.088 P056 Position #2 CTMT AUX Removed 2.88E+06 1.13E+05 5.00E+07 3.43E+04 2.40E+02 1.63E+06 1.06E+04 1.44E+03 0.093 0.109 0.663 1.987 P056 Position #3 CTMT AUX Removed 1.74E+06 6.85E+04 3.03E+07 2.08E+04 1.45E+02 9.89E+05 6.39E+03 8.71E+02 0.056 0.066 0.402 1.202 P056 Position #4 CTMT AUX Removed 1.42E+06 5.58E+04 2.47E+07 1.69E+04 1.18E+02 8.06E+05 5.20E+03 7.09E+02 0.046 0.054 0.327 0.979 P056 Position #5 CTMT AUX Removed 1.40E+06 5.52E+04 2.44E+07 1.67E+04 1.17E+02 7.98E+05 5.15E+03 7.02E+02 0.045 0.053 0.324 0.969 P012 By Direct Scan CTMT AUX Removed 2.09E+05 8.24E+03 3.64E+06 2.50E+03 1.75E+01 1.19E+05 7.68E+02 1.05E+02 0.007 0.008 0.048 0.145 P273 By Direct Scan CTMT AUX Removed 5.02E+05 1.98E+04 8.73E+06 5.99E+03 4.19E+01 2.85E+05 1.84E+03 2.51E+02 0.016 0.019 0.116 0.347 P218 By Direct Scan CTMT AUX Removed 3.39E+05 1.34E+04 5.90E+06 4.05E+03 2.83E+01 1.93E+05 1.24E+03 1.70E+02 0.011 0.013 0.078 0.234 P254 Position #1 CTMT AUX Removed 3.71E+06 1.46E+05 6.45E+07 4.43E+04 3.09E+02 2.11E+06 1.36E+04 1.86E+03 0.120 0.140 0.856 2.563 P254 Position #2 CTMT AUX Removed 1.40E+06 5.50E+04 2.43E+07 1.67E+04 1.17E+02 7.95E+05 5.13E+03 7.00E+02 0.045 0.053 0.323 0.966 P254 Position #3 CTMT AUX Removed 1.29E+06 5.08E+04 2.24E+07 1.54E+04 1.08E+02 7.33E+05 4.73E+03 6.45E+02 0.042 0.049 0.298 0.891 P254 Position #4 CTMT AUX Removed 1.34E+06 5.27E+04 2.33E+07 1.60E+04 1.12E+02 7.60E+05 4.91E+03 6.69E+02 0.043 0.051 0.309 0.924 P217 By Direct Scan CTMT AUX Removed 1.11E+05 4.36E+03 1.93E+06 1.32E+03 9.23E+00 6.29E+04 4.06E+02 5.54E+01 0.004 0.004 0.026 0.076 P221 By Direct Scan CTMT AUX Removed 8.57E+04 3.37E+03 1.49E+06 1.02E+03 7.14E+00 4.87E+04 3.14E+02 4.29E+01 0.003 0.003 0.020 0.059 P290 By Direct Scan CTMT AUX Removed 1.09E+05 4.30E+03 1.90E+06 1.30E+03 9.11E+00 6.21E+04 4.01E+02 5.46E+01 0.004 0.004 0.025 0.075 P305 By Direct Scan CTMT AUX Removed 1.17E+05 4.59E+03 2.03E+06 1.39E+03 9.72E+00 6.63E+04 4.28E+02 5.83E+01 0.004 0.004 0.027 0.081 P286 Position #1 CTMT AUX Removed 1.52E+07 5.97E+05 2.64E+08 1.81E+05 1.26E+03 8.62E+06 5.56E+04 7.58E+03 0.489 0.574 3.498 10.474 P286 Position #2 CTMT AUX Removed 3.00E+06 1.18E+05 5.22E+07 3.58E+04 2.50E+02 1.71E+06 1.10E+04 1.50E+03 0.097 0.114 0.692 2.073 P286 Position #3 CTMT AUX Removed 2.26E+06 8.89E+04 3.93E+07 2.69E+04 1.88E+02 1.28E+06 8.28E+03 1.13E+03 0.073 0.085 0.521 1.560 P286 Position #4 CTMT AUX Removed 2.07E+06 8.14E+04 3.60E+07 2.47E+04 1.72E+02 1.17E+06 7.58E+03 1.03E+03 0.067 0.078 0.477 1.428 P289 Position #1 CTMT AUX Removed 6.05E+06 2.38E+05 1.05E+08 7.21E+04 5.04E+02 3.43E+06 2.22E+04 3.02E+03 0.195 0.229 1.394 4.175 P289 Position #2 CTMT AUX Removed 2.06E+06 8.10E+04 3.58E+07 2.46E+04 1.72E+02 1.17E+06 7.55E+03 1.03E+03 0.066 0.078 0.475 1.421 P289 Position #3 CTMT AUX Removed 1.76E+06 6.93E+04 3.06E+07 2.10E+04 1.47E+02 1.00E+06 6.46E+03 8.81E+02 0.057 0.067 0.406 1.217 P289 Position #4 CTMT AUX Removed 2.17E+06 8.53E+04 3.77E+07 2.59E+04 1.81E+02 1.23E+06 7.95E+03 1.08E+03 0.070 0.082 0.500 1.497 P288 Position #1 CTMT AUX Removed 1.01E+07 3.98E+05 1.76E+08 1.21E+05 8.43E+02 5.75E+06 3.71E+04 5.06E+03 0.326 0.383 2.332 6.985 P288 Position #2 CTMT AUX Removed 2.14E+06 8.43E+04 3.72E+07 2.56E+04 1.79E+02 1.22E+06 7.86E+03 1.07E+03 0.069 0.081 0.494 1.479 P288 Position #3 CTMT AUX Removed 1.61E+06 6.32E+04 2.79E+07 1.92E+04 1.34E+02 9.13E+05 5.89E+03 8.04E+02 0.052 0.061 0.371 1.110 P288 Position #4 CTMT AUX Removed 1.86E+06 7.32E+04 3.24E+07 2.22E+04 1.55E+02 1.06E+06 6.83E+03 9.31E+02 0.060 0.070 0.429 1.285 P219 Position #1 CTMT AUX Removed 7.12E+06 2.80E+05 1.24E+08 8.49E+04 5.93E+02 4.04E+06 2.61E+04 3.56E+03 0.230 0.269 1.641 4.915 P219 Position #2 CTMT AUX Removed 2.33E+06 9.15E+04 4.04E+07 2.78E+04 1.94E+02 1.32E+06 8.53E+03 1.16E+03 0.075 0.088 0.536 1.606 P219 Position #3 CTMT AUX Removed 2.21E+06 8.68E+04 3.84E+07 2.63E+04 1.84E+02 1.25E+06 8.09E+03 1.10E+03 0.071 0.083 0.509 1.524 P219 Position #4 CTMT AUX Removed 2.65E+06 1.04E+05 4.61E+07 3.17E+04 2.21E+02 1.51E+06 9.73E+03 1.33E+03 0.086 0.100 0.612 1.832 P223 Position #1 CTMT AUX Removed 9.60E+06 3.78E+05 1.67E+08 1.15E+05 8.00E+02 5.46E+06 3.52E+04 4.80E+03 0.310 0.363 2.214 6.631 MEASUREMENT ID BETWEEN END STATE
~
=ZIONSOLUTIONSuc-An Er,e,,gyS~ Company I I I I I I
- I
- I I I I
- I I I I I I I I
- I
- I I I I
- I I I.
FSS RELEASE RECORD, REV 1 PENETRATIONS SURVEY UNITS 01112, 02112 and 05120
[91]
Auxiliary Building Penetration Measurements (continued)
H-3 (1)
Co-60 (2)
Ni-63 (1)
Sr-90 (1)
Cs-134 (2)
Cs-137 (2)
Eu-152 (2)
Eu-154 (2)
OpSOFPN OpSOFPN OpSOFB OpSOFB (pCi/m2)
(pCi/m2)
(pCi/m2)
(pCi/m2)
(pCi/m2)
(pCi/m2)
(pCi/m2)
(pCi/m2)
CTMTPN Limiting DCGL CTMT/AB DCGL Limiting DCGL P223 Position #2 CTMT AUX Removed 2.28E+06 8.97E+04 3.96E+07 2.72E+04 1.90E+02 1.30E+06 8.36E+03 1.14E+03 0.074 0.086 0.526 1.575 P223 Position #3 CTMT AUX Removed 1.96E+06 7.70E+04 3.41E+07 2.34E+04 1.63E+02 1.11E+06 7.18E+03 9.79E+02 0.063 0.074 0.452 1.353 P223 Position #4 CTMT AUX Removed 2.24E+06 8.82E+04 3.90E+07 2.67E+04 1.87E+02 1.27E+06 8.22E+03 1.12E+03 0.072 0.085 0.517 1.548 P281 Position #1 CTMT AUX Removed 1.34E+07 5.25E+05 2.32E+08 1.59E+05 1.11E+03 7.59E+06 4.90E+04 6.68E+03 0.431 0.505 3.080 9.223 P281 Position #2 CTMT AUX Removed 1.86E+06 7.31E+04 3.23E+07 2.22E+04 1.55E+02 1.06E+06 6.81E+03 9.29E+02 0.060 0.070 0.428 1.283 P281 Position #3 CTMT AUX Removed 1.27E+06 5.01E+04 2.22E+07 1.52E+04 1.06E+02 7.24E+05 4.67E+03 6.37E+02 0.041 0.048 0.294 0.880 P281 Position #4 CTMT AUX Removed 1.30E+06 5.12E+04 2.27E+07 1.55E+04 1.09E+02 7.40E+05 4.78E+03 6.51E+02 0.042 0.049 0.300 0.900 P281 Position #5 CTMT AUX Removed 1.25E+06 4.93E+04 2.18E+07 1.50E+04 1.04E+02 7.12E+05 4.60E+03 6.27E+02 0.040 0.047 0.289 0.866 P243 Position #1 CTMT AUX Removed 1.78E+07 6.98E+05 3.09E+08 2.12E+05 1.48E+03 1.01E+07 6.51E+04 8.88E+03 0.573 0.672 4.094 12.259 P243 Position #2 CTMT AUX Removed 2.07E+06 8.15E+04 3.60E+07 2.47E+04 1.73E+02 1.18E+06 7.60E+03 1.04E+03 0.067 0.078 0.478 1.430 P243 Position #3 CTMT AUX Removed 1.48E+06 5.80E+04 2.57E+07 1.76E+04 1.23E+02 8.38E+05 5.41E+03 7.38E+02 0.048 0.056 0.340 1.019 P243 Position #4 CTMT AUX Removed 1.41E+06 5.54E+04 2.45E+07 1.68E+04 1.17E+02 8.01E+05 5.17E+03 7.05E+02 0.045 0.053 0.325 0.973 P243 Position #5 CTMT AUX Removed 1.40E+06 5.51E+04 2.44E+07 1.67E+04 1.17E+02 7.96E+05 5.14E+03 7.01E+02 0.045 0.053 0.323 0.968 P303 Position #1 CTMT AUX Removed 2.07E+07 8.15E+05 3.60E+08 2.47E+05 1.73E+03 1.18E+07 7.60E+04 1.04E+04 0.668 0.783 4.776 14.303 P303 Position #2 CTMT AUX Removed 6.82E+06 2.68E+05 1.19E+08 8.14E+04 5.69E+02 3.88E+06 2.50E+04 3.41E+03 0.220 0.258 1.573 4.711 P303 Position #3 CTMT AUX Removed 9.00E+06 3.54E+05 1.56E+08 1.07E+05 7.50E+02 5.11E+06 3.30E+04 4.50E+03 0.290 0.340 2.075 6.215 P303 Position #4 CTMT AUX Removed 8.10E+06 3.18E+05 1.41E+08 9.66E+04 6.75E+02 4.60E+06 2.97E+04 4.05E+03 0.261 0.306 1.867 5.591 P303 Position #5 CTMT AUX Removed 6.82E+06 2.68E+05 1.19E+08 8.14E+04 5.69E+02 3.88E+06 2.50E+04 3.41E+03 0.220 0.258 1.573 4.711 P303 Position #6 CTMT AUX Removed 9.37E+06 3.69E+05 1.63E+08 1.12E+05 7.81E+02 5.32E+06 3.44E+04 4.69E+03 0.302 0.354 2.161 6.470 P256 Position #1 CTMT AUX Removed 1.24E+07 4.88E+05 2.16E+08 1.48E+05 1.03E+03 7.05E+06 4.55E+04 6.21E+03 0.400 0.469 2.862 8.570 P256 Position #2 CTMT AUX Removed 1.47E+06 5.79E+04 2.56E+07 1.76E+04 1.23E+02 8.36E+05 5.39E+03 7.36E+02 0.047 0.056 0.339 1.016 P256 Position #3 CTMT AUX Removed 1.18E+06 4.64E+04 2.05E+07 1.41E+04 9.83E+01 6.70E+05 4.33E+03 5.90E+02 0.038 0.045 0.272 0.814 P256 Position #4 CTMT AUX Removed 1.10E+06 4.33E+04 1.91E+07 1.31E+04 9.18E+01 6.26E+05 4.04E+03 5.51E+02 0.036 0.042 0.254 0.761 P256 Position #5 CTMT AUX Removed 1.21E+06 4.75E+04 2.10E+07 1.44E+04 1.01E+02 6.86E+05 4.43E+03 6.04E+02 0.039 0.046 0.279 0.834 P204 Position #1 CTMT AUX Removed 1.22E+07 4.79E+05 2.11E+08 1.45E+05 1.01E+03 6.91E+06 4.46E+04 6.08E+03 0.392 0.460 2.805 8.400 P204 Position #2 CTMT AUX Removed 1.84E+06 7.23E+04 3.19E+07 2.19E+04 1.53E+02 1.04E+06 6.74E+03 9.19E+02 0.059 0.069 0.424 1.269 P204 Position #3 CTMT AUX Removed 1.56E+06 6.14E+04 2.72E+07 1.86E+04 1.30E+02 8.87E+05 5.73E+03 7.81E+02 0.050 0.059 0.360 1.078 P204 Position #4 CTMT AUX Removed 1.68E+06 6.63E+04 2.93E+07 2.01E+04 1.40E+02 9.57E+05 6.18E+03 8.43E+02 0.054 0.064 0.389 1.164 P204 Position #5 CTMT AUX Removed 1.44E+06 5.67E+04 2.51E+07 1.72E+04 1.20E+02 8.20E+05 5.29E+03 7.21E+02 0.047 0.055 0.333 0.996 P242 Position #1 CTMT AUX Removed 9.91E+06 3.90E+05 1.72E+08 1.18E+05 8.26E+02 5.63E+06 3.63E+04 4.95E+03 0.320 0.375 2.285 6.842 P242 Position #2 CTMT AUX Removed 1.81E+06 7.13E+04 3.15E+07 2.16E+04 1.51E+02 1.03E+06 6.65E+03 9.06E+02 0.058 0.069 0.418 1.251 P242 Position #3 CTMT AUX Removed 1.52E+06 5.98E+04 2.64E+07 1.81E+04 1.27E+02 8.64E+05 5.58E+03 7.61E+02 0.049 0.058 0.351 1.050 P242 Position #4 CTMT AUX Removed 1.59E+06 6.27E+04 2.77E+07 1.90E+04 1.33E+02 9.06E+05 5.85E+03 7.98E+02 0.051 0.060 0.368 1.101 P242 Position #5 CTMT AUX Removed 1.55E+06 6.10E+04 2.70E+07 1.85E+04 1.29E+02 8.81E+05 5.69E+03 7.76E+02 0.050 0.059 0.358 1.071 P266 By Direct Scan CTMT AUX Removed 3.39E+05 1.33E+04 5.89E+06 4.04E+03 2.82E+01 1.92E+05 1.24E+03 1.69E+02 0.011 0.013 0.078 0.234 P269 By Direct Scan CTMT AUX Removed 7.22E+04 2.84E+03 1.25E+06 8.61E+02 6.01E+00 4.10E+04 2.65E+02 3.61E+01 0.002 0.003 0.017 0.050 P274 By Direct Scan CTMT AUX Removed 7.22E+04 2.84E+03 1.25E+06 8.61E+02 6.01E+00 4.10E+04 2.65E+02 3.61E+01 0.002 0.003 0.017 0.050 P270 By Direct Scan CTMT AUX Removed 2.78E+05 1.09E+04 4.83E+06 3.32E+03 2.32E+01 1.58E+05 1.02E+03 1.39E+02 0.009 0.011 0.064 0.192 P268 By Direct Scan CTMT AUX Removed 2.07E+05 8.13E+03 3.59E+06 2.46E+03 1.72E+01 1.17E+05 7.57E+02 1.03E+02 0.007 0.008 0.048 0.143 P222 By Direct Scan CTMT AUX Removed 6.41E+04 2.52E+03 1.11E+06 7.64E+02 5.34E+00 3.64E+04 2.35E+02 3.20E+01 0.002 0.002 0.015 0.044 P304 By Direct Scan CTMT AUX Removed 2.22E+05 8.72E+03 3.85E+06 2.64E+03 1.85E+01 1.26E+05 8.13E+02 1.11E+02 0.007 0.008 0.051 0.153 P237 Position #1 CTMT AUX Grouted 1.20E+07 4.73E+05 2.09E+08 1.43E+05 1.00E+03 6.83E+06 4.41E+04 6.01E+03 0.388 0.455 2.772 8.301 P237 Position #2 CTMT AUX Grouted 5.56E+06 2.19E+05 9.67E+07 6.63E+04 4.63E+02 3.16E+06 2.04E+04 2.78E+03 0.179 0.210 1.282 3.840 P237 Position #3 CTMT AUX Grouted 4.12E+06 1.62E+05 7.17E+07 4.92E+04 3.43E+02 2.34E+06 1.51E+04 2.06E+03 0.133 0.156 0.950 2.846 P237 Position #4 CTMT AUX Grouted 4.01E+06 1.58E+05 6.97E+07 4.78E+04 3.34E+02 2.28E+06 1.47E+04 2.00E+03 0.129 0.152 0.925 2.769 P237 Position #5 CTMT AUX Grouted 4.03E+06 1.59E+05 7.01E+07 4.81E+04 3.36E+02 2.29E+06 1.48E+04 2.02E+03 0.130 0.152 0.929 2.783 P237 Position #6 CTMT AUX Grouted 3.90E+06 1.53E+05 6.78E+07 4.65E+04 3.25E+02 2.22E+06 1.43E+04 1.95E+03 0.126 0.147 0.899 2.693 P237 Position #7 CTMT AUX Grouted 3.81E+06 1.50E+05 6.62E+07 4.54E+04 3.17E+02 2.16E+06 1.40E+04 1.90E+03 0.123 0.144 0.878 2.629 P237 Position #8 CTMT AUX Grouted 3.73E+06 1.47E+05 6.49E+07 4.45E+04 3.11E+02 2.12E+06 1.37E+04 1.87E+03 0.120 0.141 0.861 2.578 P237 Position #9 CTMT AUX Grouted 3.90E+06 1.53E+05 6.78E+07 4.66E+04 3.25E+02 2.22E+06 1.43E+04 1.95E+03 0.126 0.148 0.900 2.694 P237 Position #10 CTMT AUX Grouted 3.76E+06 1.48E+05 6.54E+07 4.49E+04 3.14E+02 2.14E+06 1.38E+04 1.88E+03 0.121 0.142 0.868 2.599 P237 Position #11 CTMT AUX Grouted 3.72E+06 1.47E+05 6.48E+07 4.44E+04 3.10E+02 2.12E+06 1.37E+04 1.86E+03 0.120 0.141 0.859 2.572 P237 Position #12 CTMT AUX Grouted 3.85E+06 1.52E+05 6.70E+07 4.60E+04 3.21E+02 2.19E+06 1.41E+04 1.93E+03 0.124 0.146 0.888 2.660 MEASUREMENT ID BETWEEN END STATE
~
= ZIONSOLUTIONSuc-An Er,e,,gyS~ Company t t t t
~
t t
t t
t t
+
t
+
t t
+
t
+
t t
I I
I I
I
FSS RELEASE RECORD, REV 1 PENETRATIONS SURVEY UNITS 01112, 02112 and 05120
[92]
Auxiliary Building Penetration Measurements (continued)
H-3 (1)
Co-60 (2)
Ni-63 (1)
Sr-90 (1)
Cs-134 (2)
Cs-137 (2)
Eu-152 (2)
Eu-154 (2)
OpSOFPN OpSOFPN OpSOFB OpSOFB (pCi/m2)
(pCi/m2)
(pCi/m2)
(pCi/m2)
(pCi/m2)
(pCi/m2)
(pCi/m2)
(pCi/m2)
CTMTPN Limiting DCGL CTMT/AB DCGL Limiting DCGL P237 Position #13 CTMT AUX Grouted 3.86E+06 1.52E+05 6.71E+07 4.61E+04 3.22E+02 2.19E+06 1.42E+04 1.93E+03 0.125 0.146 0.890 2.667 P237 Position #14 CTMT AUX Grouted 3.77E+06 1.48E+05 6.56E+07 4.50E+04 3.14E+02 2.14E+06 1.38E+04 1.89E+03 0.122 0.143 0.870 2.605 P237 Position #15 CTMT AUX Grouted 3.92E+06 1.54E+05 6.81E+07 4.67E+04 3.26E+02 2.23E+06 1.44E+04 1.96E+03 0.126 0.148 0.903 2.705 P237 Position #16 CTMT AUX Grouted 3.75E+06 1.47E+05 6.52E+07 4.47E+04 3.12E+02 2.13E+06 1.37E+04 1.87E+03 0.121 0.142 0.864 2.588 P237 Position #17 CTMT AUX Grouted 3.84E+06 1.51E+05 6.68E+07 4.58E+04 3.20E+02 2.18E+06 1.41E+04 1.92E+03 0.124 0.145 0.886 2.652 P237 Position #18 CTMT AUX Grouted 4.05E+06 1.59E+05 7.04E+07 4.83E+04 3.38E+02 2.30E+06 1.49E+04 2.03E+03 0.131 0.153 0.934 2.797 P237 Position #19 CTMT AUX Grouted 3.93E+06 1.55E+05 6.84E+07 4.69E+04 3.28E+02 2.23E+06 1.44E+04 1.97E+03 0.127 0.149 0.907 2.715 P237 Position #20 CTMT AUX Grouted 3.65E+06 1.43E+05 6.34E+07 4.35E+04 3.04E+02 2.07E+06 1.34E+04 1.82E+03 0.118 0.138 0.841 2.519 P237 Position #21 CTMT AUX Grouted 3.33E+06 1.31E+05 5.78E+07 3.97E+04 2.77E+02 1.89E+06 1.22E+04 1.66E+03 0.107 0.126 0.767 2.297 P237 Position #22 CTMT AUX Grouted 3.35E+06 1.32E+05 5.82E+07 4.00E+04 2.79E+02 1.90E+06 1.23E+04 1.67E+03 0.108 0.127 0.772 2.313 P237 Position #23 CTMT AUX Grouted 3.30E+06 1.30E+05 5.73E+07 3.93E+04 2.75E+02 1.87E+06 1.21E+04 1.65E+03 0.106 0.125 0.760 2.277 P237 Position #24 CTMT AUX Grouted 3.19E+06 1.25E+05 5.54E+07 3.80E+04 2.66E+02 1.81E+06 1.17E+04 1.59E+03 0.103 0.121 0.735 2.202 P237 Position #25 CTMT AUX Grouted 3.30E+06 1.30E+05 5.75E+07 3.94E+04 2.75E+02 1.88E+06 1.21E+04 1.65E+03 0.107 0.125 0.762 2.282 P237 Position #26 CTMT AUX Grouted 3.21E+06 1.26E+05 5.58E+07 3.83E+04 2.68E+02 1.82E+06 1.18E+04 1.61E+03 0.104 0.121 0.740 2.217 P237 Position #27 CTMT AUX Grouted 3.30E+06 1.30E+05 5.73E+07 3.93E+04 2.75E+02 1.87E+06 1.21E+04 1.65E+03 0.106 0.125 0.760 2.276 P237 Position #28 CTMT AUX Grouted 3.31E+06 1.30E+05 5.75E+07 3.95E+04 2.76E+02 1.88E+06 1.21E+04 1.66E+03 0.107 0.125 0.763 2.286 P237 Position #29 CTMT AUX Grouted 3.32E+06 1.31E+05 5.78E+07 3.97E+04 2.77E+02 1.89E+06 1.22E+04 1.66E+03 0.107 0.126 0.766 2.295 P237 Position #30 CTMT AUX Grouted 3.24E+06 1.28E+05 5.64E+07 3.87E+04 2.70E+02 1.84E+06 1.19E+04 1.62E+03 0.105 0.123 0.748 2.239 P237 Position #31 CTMT AUX Grouted 3.24E+06 1.28E+05 5.64E+07 3.87E+04 2.70E+02 1.84E+06 1.19E+04 1.62E+03 0.105 0.123 0.748 2.239 P237 Position #32 CTMT AUX Grouted 3.26E+06 1.28E+05 5.67E+07 3.89E+04 2.72E+02 1.85E+06 1.20E+04 1.63E+03 0.105 0.123 0.752 2.252 P237 Position #33 CTMT AUX Grouted 3.23E+06 1.27E+05 5.61E+07 3.85E+04 2.69E+02 1.83E+06 1.18E+04 1.61E+03 0.104 0.122 0.744 2.228 P237 Position #34 CTMT AUX Grouted 3.22E+06 1.27E+05 5.60E+07 3.84E+04 2.68E+02 1.83E+06 1.18E+04 1.61E+03 0.104 0.122 0.743 2.224 P237 Position #35 CTMT AUX Grouted 3.24E+06 1.27E+05 5.63E+07 3.86E+04 2.70E+02 1.84E+06 1.19E+04 1.62E+03 0.104 0.122 0.746 2.234 P237 Position #36 CTMT AUX Grouted 3.27E+06 1.29E+05 5.69E+07 3.91E+04 2.73E+02 1.86E+06 1.20E+04 1.64E+03 0.106 0.124 0.755 2.262 P237 Position #37 CTMT AUX Grouted 3.26E+06 1.28E+05 5.67E+07 3.89E+04 2.72E+02 1.85E+06 1.20E+04 1.63E+03 0.105 0.123 0.751 2.250 P237 Position #38 CTMT AUX Grouted 3.24E+06 1.27E+05 5.63E+07 3.86E+04 2.70E+02 1.84E+06 1.19E+04 1.62E+03 0.104 0.122 0.747 2.236 P237 Position #39 CTMT AUX Grouted 3.33E+06 1.31E+05 5.79E+07 3.97E+04 2.77E+02 1.89E+06 1.22E+04 1.66E+03 0.107 0.126 0.768 2.299 P237 Position #40 CTMT AUX Grouted 3.22E+06 1.27E+05 5.60E+07 3.84E+04 2.68E+02 1.83E+06 1.18E+04 1.61E+03 0.104 0.122 0.743 2.224 P237 Position #41 CTMT AUX Grouted 3.28E+06 1.29E+05 5.71E+07 3.92E+04 2.74E+02 1.86E+06 1.20E+04 1.64E+03 0.106 0.124 0.757 2.266 P237 Position #42 CTMT AUX Grouted 3.26E+06 1.28E+05 5.67E+07 3.89E+04 2.72E+02 1.85E+06 1.20E+04 1.63E+03 0.105 0.123 0.752 2.253 P237 Position #43 CTMT AUX Grouted 3.28E+06 1.29E+05 5.70E+07 3.91E+04 2.73E+02 1.86E+06 1.20E+04 1.64E+03 0.106 0.124 0.756 2.265 P237 Position #44 CTMT AUX Grouted 3.25E+06 1.28E+05 5.64E+07 3.87E+04 2.70E+02 1.84E+06 1.19E+04 1.62E+03 0.105 0.123 0.748 2.241 P237 Position #45 CTMT AUX Grouted 3.38E+06 1.33E+05 5.87E+07 4.03E+04 2.81E+02 1.92E+06 1.24E+04 1.69E+03 0.109 0.128 0.779 2.332 P237 Position #46 CTMT AUX Grouted 3.26E+06 1.28E+05 5.67E+07 3.89E+04 2.72E+02 1.85E+06 1.20E+04 1.63E+03 0.105 0.123 0.752 2.252 P237 Position #47 CTMT AUX Grouted 3.33E+06 1.31E+05 5.79E+07 3.97E+04 2.77E+02 1.89E+06 1.22E+04 1.66E+03 0.107 0.126 0.768 2.299 P237 Position #48 CTMT AUX Grouted 3.34E+06 1.31E+05 5.81E+07 3.99E+04 2.78E+02 1.90E+06 1.22E+04 1.67E+03 0.108 0.126 0.770 2.307 P237 Position #49 CTMT AUX Grouted 3.23E+06 1.27E+05 5.62E+07 3.85E+04 2.69E+02 1.84E+06 1.18E+04 1.62E+03 0.104 0.122 0.745 2.230 P237 Position #50 CTMT AUX Grouted 3.27E+06 1.29E+05 5.69E+07 3.90E+04 2.73E+02 1.86E+06 1.20E+04 1.64E+03 0.106 0.124 0.754 2.258 P236 Position #1 CTMT AUX Grouted 1.04E+07 4.10E+05 1.81E+08 1.24E+05 8.69E+02 5.93E+06 3.83E+04 5.22E+03 0.337 0.395 2.405 7.203 P236 Position #2 CTMT AUX Grouted 5.58E+06 2.20E+05 9.71E+07 6.66E+04 4.65E+02 3.17E+06 2.05E+04 2.79E+03 0.180 0.211 1.287 3.855 P236 Position #3 CTMT AUX Grouted 4.00E+06 1.57E+05 6.96E+07 4.78E+04 3.34E+02 2.27E+06 1.47E+04 2.00E+03 0.129 0.151 0.923 2.765 P236 Position #4 CTMT AUX Grouted 3.96E+06 1.56E+05 6.89E+07 4.73E+04 3.30E+02 2.25E+06 1.45E+04 1.98E+03 0.128 0.150 0.914 2.738 P236 Position #5 CTMT AUX Grouted 3.93E+06 1.55E+05 6.84E+07 4.69E+04 3.28E+02 2.24E+06 1.44E+04 1.97E+03 0.127 0.149 0.907 2.717 P236 Position #6 CTMT AUX Grouted 3.82E+06 1.50E+05 6.65E+07 4.56E+04 3.19E+02 2.17E+06 1.40E+04 1.91E+03 0.123 0.145 0.882 2.641 P236 Position #7 CTMT AUX Grouted 3.65E+06 1.44E+05 6.35E+07 4.36E+04 3.04E+02 2.08E+06 1.34E+04 1.83E+03 0.118 0.138 0.842 2.522 P236 Position #8 CTMT AUX Grouted 3.63E+06 1.43E+05 6.32E+07 4.34E+04 3.03E+02 2.06E+06 1.33E+04 1.82E+03 0.117 0.137 0.838 2.510 P236 Position #9 CTMT AUX Grouted 3.58E+06 1.41E+05 6.22E+07 4.27E+04 2.98E+02 2.03E+06 1.31E+04 1.79E+03 0.116 0.135 0.826 2.472 P236 Position #10 CTMT AUX Grouted 3.62E+06 1.43E+05 6.30E+07 4.32E+04 3.02E+02 2.06E+06 1.33E+04 1.81E+03 0.117 0.137 0.836 2.503 P236 Position #11 CTMT AUX Grouted 3.51E+06 1.38E+05 6.10E+07 4.19E+04 2.92E+02 1.99E+06 1.29E+04 1.75E+03 0.113 0.133 0.809 2.423 P236 Position #12 CTMT AUX Grouted 3.59E+06 1.41E+05 6.24E+07 4.28E+04 2.99E+02 2.04E+06 1.32E+04 1.80E+03 0.116 0.136 0.828 2.479 P236 Position #13 CTMT AUX Grouted 3.62E+06 1.43E+05 6.30E+07 4.32E+04 3.02E+02 2.06E+06 1.33E+04 1.81E+03 0.117 0.137 0.836 2.502 P236 Position #14 CTMT AUX Grouted 3.56E+06 1.40E+05 6.19E+07 4.25E+04 2.97E+02 2.02E+06 1.30E+04 1.78E+03 0.115 0.135 0.821 2.457 P236 Position #15 CTMT AUX Grouted 3.58E+06 1.41E+05 6.22E+07 4.27E+04 2.98E+02 2.03E+06 1.31E+04 1.79E+03 0.115 0.135 0.825 2.472 MEASUREMENT ID BETWEEN END STATE
~
=ZIONSOLUTIONSuc-An Er,e,,gyS~ Company
FSS RELEASE RECORD, REV 1 PENETRATIONS SURVEY UNITS 01112, 02112 and 05120
[93]
Auxiliary Building Penetration Measurements (continued)
H-3 (1)
Co-60 (2)
Ni-63 (1)
Sr-90 (1)
Cs-134 (2)
Cs-137 (2)
Eu-152 (2)
Eu-154 (2)
OpSOFPN OpSOFPN OpSOFB OpSOFB (pCi/m2)
(pCi/m2)
(pCi/m2)
(pCi/m2)
(pCi/m2)
(pCi/m2)
(pCi/m2)
(pCi/m2)
CTMTPN Limiting DCGL CTMT/AB DCGL Limiting DCGL P236 Position #16 CTMT AUX Grouted 3.61E+06 1.42E+05 6.28E+07 4.31E+04 3.01E+02 2.05E+06 1.32E+04 1.81E+03 0.117 0.137 0.833 2.495 P236 Position #17 CTMT AUX Grouted 3.63E+06 1.43E+05 6.32E+07 4.33E+04 3.03E+02 2.06E+06 1.33E+04 1.82E+03 0.117 0.137 0.838 2.508 P236 Position #18 CTMT AUX Grouted 3.66E+06 1.44E+05 6.37E+07 4.37E+04 3.05E+02 2.08E+06 1.34E+04 1.83E+03 0.118 0.139 0.845 2.530 P236 Position #19 CTMT AUX Grouted 3.65E+06 1.44E+05 6.35E+07 4.36E+04 3.05E+02 2.08E+06 1.34E+04 1.83E+03 0.118 0.138 0.843 2.523 P236 Position #20 CTMT AUX Grouted 3.47E+06 1.36E+05 6.03E+07 4.14E+04 2.89E+02 1.97E+06 1.27E+04 1.73E+03 0.112 0.131 0.799 2.394 P236 Position #21 CTMT AUX Grouted 3.38E+06 1.33E+05 5.89E+07 4.04E+04 2.82E+02 1.92E+06 1.24E+04 1.69E+03 0.109 0.128 0.781 2.338 P236 Position #22 CTMT AUX Grouted 3.33E+06 1.31E+05 5.79E+07 3.97E+04 2.77E+02 1.89E+06 1.22E+04 1.66E+03 0.107 0.126 0.768 2.299 P236 Position #23 CTMT AUX Grouted 3.20E+06 1.26E+05 5.57E+07 3.82E+04 2.67E+02 1.82E+06 1.17E+04 1.60E+03 0.103 0.121 0.738 2.211 P236 Position #24 CTMT AUX Grouted 3.12E+06 1.23E+05 5.42E+07 3.72E+04 2.60E+02 1.77E+06 1.14E+04 1.56E+03 0.101 0.118 0.719 2.154 P236 Position #25 CTMT AUX Grouted 3.18E+06 1.25E+05 5.52E+07 3.79E+04 2.65E+02 1.80E+06 1.16E+04 1.59E+03 0.103 0.120 0.733 2.194 P236 Position #26 CTMT AUX Grouted 3.19E+06 1.25E+05 5.54E+07 3.80E+04 2.66E+02 1.81E+06 1.17E+04 1.59E+03 0.103 0.121 0.735 2.201 P236 Position #27 CTMT AUX Grouted 3.28E+06 1.29E+05 5.70E+07 3.91E+04 2.73E+02 1.86E+06 1.20E+04 1.64E+03 0.106 0.124 0.756 2.264 P236 Position #28 CTMT AUX Grouted 3.33E+06 1.31E+05 5.78E+07 3.97E+04 2.77E+02 1.89E+06 1.22E+04 1.66E+03 0.107 0.126 0.767 2.298 P236 Position #29 CTMT AUX Grouted 3.24E+06 1.28E+05 5.64E+07 3.87E+04 2.70E+02 1.84E+06 1.19E+04 1.62E+03 0.105 0.123 0.748 2.239 P236 Position #30 CTMT AUX Grouted 3.25E+06 1.28E+05 5.65E+07 3.88E+04 2.71E+02 1.85E+06 1.19E+04 1.63E+03 0.105 0.123 0.750 2.245 P236 Position #31 CTMT AUX Grouted 3.31E+06 1.30E+05 5.75E+07 3.94E+04 2.75E+02 1.88E+06 1.21E+04 1.65E+03 0.107 0.125 0.762 2.282 P236 Position #32 CTMT AUX Grouted 3.30E+06 1.30E+05 5.73E+07 3.93E+04 2.75E+02 1.87E+06 1.21E+04 1.65E+03 0.106 0.125 0.760 2.277 P236 Position #33 CTMT AUX Grouted 3.15E+06 1.24E+05 5.48E+07 3.76E+04 2.63E+02 1.79E+06 1.16E+04 1.58E+03 0.102 0.119 0.727 2.176 P236 Position #34 CTMT AUX Grouted 3.28E+06 1.29E+05 5.71E+07 3.92E+04 2.74E+02 1.87E+06 1.20E+04 1.64E+03 0.106 0.124 0.757 2.267 P236 Position #35 CTMT AUX Grouted 3.29E+06 1.29E+05 5.72E+07 3.92E+04 2.74E+02 1.87E+06 1.21E+04 1.64E+03 0.106 0.124 0.758 2.270 P236 Position #36 CTMT AUX Grouted 3.20E+06 1.26E+05 5.56E+07 3.81E+04 2.66E+02 1.82E+06 1.17E+04 1.60E+03 0.103 0.121 0.737 2.207 P236 Position #37 CTMT AUX Grouted 3.35E+06 1.32E+05 5.83E+07 4.00E+04 2.79E+02 1.90E+06 1.23E+04 1.68E+03 0.108 0.127 0.773 2.315 P236 Position #38 CTMT AUX Grouted 3.24E+06 1.28E+05 5.64E+07 3.87E+04 2.70E+02 1.84E+06 1.19E+04 1.62E+03 0.105 0.123 0.748 2.241 P236 Position #39 CTMT AUX Grouted 3.35E+06 1.32E+05 5.82E+07 3.99E+04 2.79E+02 1.90E+06 1.23E+04 1.67E+03 0.108 0.127 0.772 2.311 P236 Position #40 CTMT AUX Grouted 3.40E+06 1.34E+05 5.92E+07 4.06E+04 2.84E+02 1.93E+06 1.25E+04 1.70E+03 0.110 0.129 0.785 2.350 P236 Position #41 CTMT AUX Grouted 3.36E+06 1.32E+05 5.84E+07 4.01E+04 2.80E+02 1.91E+06 1.23E+04 1.68E+03 0.108 0.127 0.775 2.321 P236 Position #42 CTMT AUX Grouted 3.29E+06 1.30E+05 5.73E+07 3.93E+04 2.74E+02 1.87E+06 1.21E+04 1.65E+03 0.106 0.125 0.759 2.274 P236 Position #43 CTMT AUX Grouted 3.34E+06 1.32E+05 5.81E+07 3.99E+04 2.79E+02 1.90E+06 1.23E+04 1.67E+03 0.108 0.127 0.771 2.309 P236 Position #44 CTMT AUX Grouted 3.33E+06 1.31E+05 5.80E+07 3.98E+04 2.78E+02 1.89E+06 1.22E+04 1.67E+03 0.108 0.126 0.769 2.303 P236 Position #45 CTMT AUX Grouted 3.30E+06 1.30E+05 5.74E+07 3.94E+04 2.75E+02 1.88E+06 1.21E+04 1.65E+03 0.106 0.125 0.761 2.279 P236 Position #46 CTMT AUX Grouted 3.39E+06 1.34E+05 5.90E+07 4.05E+04 2.83E+02 1.93E+06 1.24E+04 1.70E+03 0.110 0.128 0.783 2.344 P236 Position #47 CTMT AUX Grouted 3.41E+06 1.34E+05 5.94E+07 4.07E+04 2.85E+02 1.94E+06 1.25E+04 1.71E+03 0.110 0.129 0.787 2.358 P236 Position #48 CTMT AUX Grouted 3.42E+06 1.35E+05 5.96E+07 4.09E+04 2.85E+02 1.95E+06 1.26E+04 1.71E+03 0.111 0.130 0.790 2.365 P236 Position #49 CTMT AUX Grouted 3.33E+06 1.31E+05 5.80E+07 3.98E+04 2.78E+02 1.89E+06 1.22E+04 1.67E+03 0.108 0.126 0.769 2.302 P236 Position #50 CTMT AUX Grouted 3.48E+06 1.37E+05 6.05E+07 4.15E+04 2.90E+02 1.98E+06 1.28E+04 1.74E+03 0.112 0.132 0.803 2.404 P235 Position #1 CTMT AUX Grouted 9.25E+06 3.64E+05 1.61E+08 1.10E+05 7.71E+02 5.25E+06 3.39E+04 4.62E+03 0.298 0.350 2.133 6.387 P235 Position #2 CTMT AUX Grouted 4.94E+06 1.94E+05 8.59E+07 5.90E+04 4.12E+02 2.81E+06 1.81E+04 2.47E+03 0.159 0.187 1.140 3.413 P235 Position #3 CTMT AUX Grouted 3.96E+06 1.56E+05 6.89E+07 4.73E+04 3.30E+02 2.25E+06 1.45E+04 1.98E+03 0.128 0.150 0.914 2.736 P235 Position #4 CTMT AUX Grouted 4.01E+06 1.58E+05 6.97E+07 4.78E+04 3.34E+02 2.28E+06 1.47E+04 2.00E+03 0.129 0.152 0.924 2.767 P235 Position #5 CTMT AUX Grouted 3.96E+06 1.56E+05 6.89E+07 4.73E+04 3.30E+02 2.25E+06 1.45E+04 1.98E+03 0.128 0.150 0.914 2.737 P235 Position #6 CTMT AUX Grouted 3.99E+06 1.57E+05 6.94E+07 4.76E+04 3.32E+02 2.27E+06 1.46E+04 1.99E+03 0.129 0.151 0.920 2.754 P235 Position #7 CTMT AUX Grouted 3.91E+06 1.54E+05 6.80E+07 4.67E+04 3.26E+02 2.22E+06 1.43E+04 1.96E+03 0.126 0.148 0.902 2.701 P235 Position #8 CTMT AUX Grouted 3.95E+06 1.55E+05 6.87E+07 4.71E+04 3.29E+02 2.24E+06 1.45E+04 1.97E+03 0.127 0.149 0.911 2.727 P235 Position #9 CTMT AUX Grouted 4.01E+06 1.58E+05 6.97E+07 4.78E+04 3.34E+02 2.28E+06 1.47E+04 2.00E+03 0.129 0.152 0.925 2.769 P235 Position #10 CTMT AUX Grouted 4.00E+06 1.57E+05 6.95E+07 4.77E+04 3.33E+02 2.27E+06 1.47E+04 2.00E+03 0.129 0.151 0.922 2.760 P235 Position #11 CTMT AUX Grouted 3.88E+06 1.53E+05 6.75E+07 4.63E+04 3.24E+02 2.21E+06 1.42E+04 1.94E+03 0.125 0.147 0.896 2.682 P235 Position #12 CTMT AUX Grouted 3.89E+06 1.53E+05 6.77E+07 4.65E+04 3.24E+02 2.21E+06 1.43E+04 1.95E+03 0.126 0.147 0.898 2.689 P235 Position #13 CTMT AUX Grouted 3.87E+06 1.52E+05 6.73E+07 4.62E+04 3.23E+02 2.20E+06 1.42E+04 1.94E+03 0.125 0.146 0.892 2.672 P235 Position #14 CTMT AUX Grouted 3.87E+06 1.52E+05 6.73E+07 4.62E+04 3.22E+02 2.20E+06 1.42E+04 1.93E+03 0.125 0.146 0.892 2.671 P235 Position #15 CTMT AUX Grouted 3.85E+06 1.51E+05 6.69E+07 4.59E+04 3.20E+02 2.18E+06 1.41E+04 1.92E+03 0.124 0.145 0.887 2.656 P235 Position #16 CTMT AUX Grouted 3.78E+06 1.49E+05 6.57E+07 4.51E+04 3.15E+02 2.15E+06 1.39E+04 1.89E+03 0.122 0.143 0.872 2.610 P235 Position #17 CTMT AUX Grouted 3.82E+06 1.50E+05 6.64E+07 4.56E+04 3.18E+02 2.17E+06 1.40E+04 1.91E+03 0.123 0.144 0.880 2.637 P235 Position #18 CTMT AUX Grouted 3.77E+06 1.48E+05 6.56E+07 4.50E+04 3.15E+02 2.14E+06 1.38E+04 1.89E+03 0.122 0.143 0.870 2.607 MEASUREMENT ID BETWEEN END STATE
~
=ZIONSOLUTIONSuc-An Er,e,,gyS~ Company
FSS RELEASE RECORD, REV 1 PENETRATIONS SURVEY UNITS 01112, 02112 and 05120
[94]
Auxiliary Building Penetration Measurements (continued)
H-3 (1)
Co-60 (2)
Ni-63 (1)
Sr-90 (1)
Cs-134 (2)
Cs-137 (2)
Eu-152 (2)
Eu-154 (2)
OpSOFPN OpSOFPN OpSOFB OpSOFB (pCi/m2)
(pCi/m2)
(pCi/m2)
(pCi/m2)
(pCi/m2)
(pCi/m2)
(pCi/m2)
(pCi/m2)
CTMTPN Limiting DCGL CTMT/AB DCGL Limiting DCGL P235 Position #19 CTMT AUX Grouted 3.70E+06 1.45E+05 6.43E+07 4.41E+04 3.08E+02 2.10E+06 1.36E+04 1.85E+03 0.119 0.140 0.853 2.553 P235 Position #20 CTMT AUX Grouted 3.53E+06 1.39E+05 6.13E+07 4.21E+04 2.94E+02 2.00E+06 1.29E+04 1.76E+03 0.114 0.133 0.814 2.437 P235 Position #21 CTMT AUX Grouted 3.45E+06 1.36E+05 5.99E+07 4.11E+04 2.87E+02 1.96E+06 1.26E+04 1.72E+03 0.111 0.130 0.795 2.380 P235 Position #22 CTMT AUX Grouted 3.37E+06 1.33E+05 5.86E+07 4.02E+04 2.81E+02 1.92E+06 1.24E+04 1.69E+03 0.109 0.128 0.778 2.329 P235 Position #23 CTMT AUX Grouted 3.32E+06 1.31E+05 5.77E+07 3.96E+04 2.77E+02 1.89E+06 1.22E+04 1.66E+03 0.107 0.126 0.765 2.292 P235 Position #24 CTMT AUX Grouted 3.23E+06 1.27E+05 5.62E+07 3.85E+04 2.69E+02 1.83E+06 1.18E+04 1.61E+03 0.104 0.122 0.745 2.230 P235 Position #25 CTMT AUX Grouted 3.26E+06 1.28E+05 5.67E+07 3.89E+04 2.72E+02 1.85E+06 1.20E+04 1.63E+03 0.105 0.123 0.752 2.253 P235 Position #26 CTMT AUX Grouted 3.26E+06 1.28E+05 5.67E+07 3.89E+04 2.72E+02 1.85E+06 1.20E+04 1.63E+03 0.105 0.123 0.753 2.254 P235 Position #27 CTMT AUX Grouted 3.39E+06 1.33E+05 5.89E+07 4.04E+04 2.82E+02 1.92E+06 1.24E+04 1.69E+03 0.109 0.128 0.781 2.339 P235 Position #28 CTMT AUX Grouted 3.30E+06 1.30E+05 5.74E+07 3.94E+04 2.75E+02 1.87E+06 1.21E+04 1.65E+03 0.106 0.125 0.761 2.279 P235 Position #29 CTMT AUX Grouted 3.38E+06 1.33E+05 5.88E+07 4.04E+04 2.82E+02 1.92E+06 1.24E+04 1.69E+03 0.109 0.128 0.780 2.337 P235 Position #30 CTMT AUX Grouted 3.33E+06 1.31E+05 5.78E+07 3.97E+04 2.77E+02 1.89E+06 1.22E+04 1.66E+03 0.107 0.126 0.767 2.297 P235 Position #31 CTMT AUX Grouted 3.31E+06 1.30E+05 5.75E+07 3.94E+04 2.75E+02 1.88E+06 1.21E+04 1.65E+03 0.107 0.125 0.762 2.282 P235 Position #32 CTMT AUX Grouted 3.31E+06 1.30E+05 5.76E+07 3.95E+04 2.76E+02 1.88E+06 1.22E+04 1.66E+03 0.107 0.125 0.764 2.289 P235 Position #33 CTMT AUX Grouted 3.25E+06 1.28E+05 5.66E+07 3.88E+04 2.71E+02 1.85E+06 1.19E+04 1.63E+03 0.105 0.123 0.750 2.246 P235 Position #34 CTMT AUX Grouted 3.27E+06 1.29E+05 5.68E+07 3.90E+04 2.72E+02 1.86E+06 1.20E+04 1.63E+03 0.105 0.124 0.754 2.258 P235 Position #35 CTMT AUX Grouted 3.27E+06 1.29E+05 5.69E+07 3.91E+04 2.73E+02 1.86E+06 1.20E+04 1.64E+03 0.106 0.124 0.755 2.261 P235 Position #36 CTMT AUX Grouted 3.31E+06 1.30E+05 5.76E+07 3.95E+04 2.76E+02 1.88E+06 1.21E+04 1.66E+03 0.107 0.125 0.764 2.287 P235 Position #37 CTMT AUX Grouted 3.28E+06 1.29E+05 5.70E+07 3.91E+04 2.73E+02 1.86E+06 1.20E+04 1.64E+03 0.106 0.124 0.756 2.264 P235 Position #38 CTMT AUX Grouted 3.38E+06 1.33E+05 5.87E+07 4.03E+04 2.82E+02 1.92E+06 1.24E+04 1.69E+03 0.109 0.128 0.779 2.333 P235 Position #39 CTMT AUX Grouted 3.33E+06 1.31E+05 5.79E+07 3.98E+04 2.78E+02 1.89E+06 1.22E+04 1.67E+03 0.108 0.126 0.768 2.301 P235 Position #40 CTMT AUX Grouted 3.28E+06 1.29E+05 5.70E+07 3.91E+04 2.73E+02 1.86E+06 1.20E+04 1.64E+03 0.106 0.124 0.756 2.264 P235 Position #41 CTMT AUX Grouted 3.28E+06 1.29E+05 5.71E+07 3.92E+04 2.74E+02 1.87E+06 1.20E+04 1.64E+03 0.106 0.124 0.757 2.267 P235 Position #42 CTMT AUX Grouted 3.36E+06 1.32E+05 5.84E+07 4.01E+04 2.80E+02 1.91E+06 1.23E+04 1.68E+03 0.108 0.127 0.775 2.321 P235 Position #43 CTMT AUX Grouted 3.38E+06 1.33E+05 5.87E+07 4.03E+04 2.82E+02 1.92E+06 1.24E+04 1.69E+03 0.109 0.128 0.779 2.333 P235 Position #44 CTMT AUX Grouted 3.36E+06 1.32E+05 5.84E+07 4.01E+04 2.80E+02 1.91E+06 1.23E+04 1.68E+03 0.108 0.127 0.775 2.321 P235 Position #45 CTMT AUX Grouted 3.38E+06 1.33E+05 5.88E+07 4.03E+04 2.82E+02 1.92E+06 1.24E+04 1.69E+03 0.109 0.128 0.779 2.334 P235 Position #46 CTMT AUX Grouted 3.52E+06 1.38E+05 6.12E+07 4.20E+04 2.93E+02 2.00E+06 1.29E+04 1.76E+03 0.114 0.133 0.812 2.431 P235 Position #47 CTMT AUX Grouted 3.50E+06 1.38E+05 6.08E+07 4.17E+04 2.91E+02 1.99E+06 1.28E+04 1.75E+03 0.113 0.132 0.807 2.415 P235 Position #48 CTMT AUX Grouted 3.43E+06 1.35E+05 5.97E+07 4.10E+04 2.86E+02 1.95E+06 1.26E+04 1.72E+03 0.111 0.130 0.792 2.371 P235 Position #49 CTMT AUX Grouted 3.43E+06 1.35E+05 5.96E+07 4.09E+04 2.86E+02 1.95E+06 1.26E+04 1.71E+03 0.111 0.130 0.790 2.367 P235 Position #50 CTMT AUX Grouted 3.62E+06 1.42E+05 6.30E+07 4.32E+04 3.02E+02 2.06E+06 1.33E+04 1.81E+03 0.117 0.137 0.835 2.501 P323 Position #1 CTMT AUX Grouted 1.40E+07 5.50E+05 2.43E+08 1.67E+05 1.16E+03 7.94E+06 5.12E+04 6.99E+03 0.451 0.529 3.222 9.649 P323 Position #2 CTMT AUX Grouted 1.81E+07 7.12E+05 3.15E+08 2.16E+05 1.51E+03 1.03E+07 6.64E+04 9.06E+03 0.584 0.685 4.176 12.506 P323 Position #3 CTMT AUX Grouted 6.56E+06 2.58E+05 1.14E+08 7.82E+04 5.47E+02 3.73E+06 2.40E+04 3.28E+03 0.212 0.248 1.512 4.528 P323 Position #4 CTMT AUX Grouted 5.02E+06 1.98E+05 8.73E+07 5.99E+04 4.19E+02 2.85E+06 1.84E+04 2.51E+03 0.162 0.190 1.158 3.468 P323 Position #5 CTMT AUX Grouted 5.22E+06 2.05E+05 9.07E+07 6.22E+04 4.35E+02 2.96E+06 1.91E+04 2.61E+03 0.168 0.197 1.203 3.602 P323 Position #6 CTMT AUX Grouted 6.08E+06 2.39E+05 1.06E+08 7.26E+04 5.07E+02 3.46E+06 2.23E+04 3.04E+03 0.196 0.230 1.403 4.201 P323 Position #7 CTMT AUX Grouted 6.12E+06 2.41E+05 1.06E+08 7.30E+04 5.10E+02 3.47E+06 2.24E+04 3.06E+03 0.197 0.231 1.410 4.223 P323 Position #8 CTMT AUX Grouted 6.28E+06 2.47E+05 1.09E+08 7.49E+04 5.23E+02 3.57E+06 2.30E+04 3.14E+03 0.203 0.237 1.447 4.334 P323 Position #9 CTMT AUX Grouted 7.77E+06 3.06E+05 1.35E+08 9.27E+04 6.48E+02 4.42E+06 2.85E+04 3.89E+03 0.251 0.294 1.792 5.367 P323 Position #10 CTMT AUX Grouted 7.51E+06 2.95E+05 1.31E+08 8.96E+04 6.26E+02 4.27E+06 2.75E+04 3.75E+03 0.242 0.284 1.731 5.184 P323 Position #11 CTMT AUX Grouted 5.41E+06 2.13E+05 9.41E+07 6.46E+04 4.51E+02 3.08E+06 1.98E+04 2.71E+03 0.175 0.205 1.248 3.738 P323 Position #12 CTMT AUX Grouted 4.81E+06 1.89E+05 8.37E+07 5.74E+04 4.01E+02 2.73E+06 1.76E+04 2.41E+03 0.155 0.182 1.110 3.323 P323 Position #13 CTMT AUX Grouted 4.64E+06 1.83E+05 8.07E+07 5.54E+04 3.87E+02 2.64E+06 1.70E+04 2.32E+03 0.150 0.176 1.071 3.206 P323 Position #14 CTMT AUX Grouted 4.49E+06 1.77E+05 7.80E+07 5.36E+04 3.74E+02 2.55E+06 1.65E+04 2.24E+03 0.145 0.170 1.035 3.100 P323 Position #15 CTMT AUX Grouted 4.53E+06 1.78E+05 7.87E+07 5.40E+04 3.77E+02 2.57E+06 1.66E+04 2.26E+03 0.146 0.171 1.044 3.127 P323 Position #16 CTMT AUX Grouted 4.59E+06 1.80E+05 7.98E+07 5.47E+04 3.82E+02 2.61E+06 1.68E+04 2.29E+03 0.148 0.174 1.058 3.168 P323 Position #17 CTMT AUX Grouted 5.38E+06 2.11E+05 9.35E+07 6.41E+04 4.48E+02 3.05E+06 1.97E+04 2.69E+03 0.173 0.203 1.240 3.713 P323 Position #18 CTMT AUX Grouted 7.88E+06 3.10E+05 1.37E+08 9.40E+04 6.57E+02 4.48E+06 2.89E+04 3.94E+03 0.254 0.298 1.818 5.443 P323 Position #19 CTMT AUX Grouted 6.04E+06 2.38E+05 1.05E+08 7.20E+04 5.03E+02 3.43E+06 2.21E+04 3.02E+03 0.195 0.228 1.392 4.170 P323 Position #20 CTMT AUX Grouted 4.95E+06 1.95E+05 8.60E+07 5.90E+04 4.12E+02 2.81E+06 1.81E+04 2.47E+03 0.160 0.187 1.141 3.417 P323 Position #21 CTMT AUX Grouted 4.58E+06 1.80E+05 7.96E+07 5.46E+04 3.82E+02 2.60E+06 1.68E+04 2.29E+03 0.148 0.173 1.056 3.163 MEASUREMENT ID BETWEEN END STATE
~
=ZIONSOLUTIONSuc-An Er,e,,gyS~ Company
FSS RELEASE RECORD, REV 1 PENETRATIONS SURVEY UNITS 01112, 02112 and 05120
[95]
Auxiliary Building Penetration Measurements (continued)
H-3 (1)
Co-60 (2)
Ni-63 (1)
Sr-90 (1)
Cs-134 (2)
Cs-137 (2)
Eu-152 (2)
Eu-154 (2)
OpSOFPN OpSOFPN OpSOFB OpSOFB (pCi/m2)
(pCi/m2)
(pCi/m2)
(pCi/m2)
(pCi/m2)
(pCi/m2)
(pCi/m2)
(pCi/m2)
CTMTPN Limiting DCGL CTMT/AB DCGL Limiting DCGL P323 Position #22 CTMT AUX Grouted 4.07E+06 1.60E+05 7.07E+07 4.85E+04 3.39E+02 2.31E+06 1.49E+04 2.03E+03 0.131 0.154 0.938 2.810 P323 Position #23 CTMT AUX Grouted 4.02E+06 1.58E+05 6.99E+07 4.80E+04 3.35E+02 2.28E+06 1.47E+04 2.01E+03 0.130 0.152 0.927 2.776 P323 Position #24 CTMT AUX Grouted 3.87E+06 1.52E+05 6.73E+07 4.62E+04 3.23E+02 2.20E+06 1.42E+04 1.94E+03 0.125 0.146 0.893 2.674 P323 Position #25 CTMT AUX Grouted 3.76E+06 1.48E+05 6.54E+07 4.49E+04 3.13E+02 2.14E+06 1.38E+04 1.88E+03 0.121 0.142 0.867 2.598 P323 Position #26 CTMT AUX Grouted 4.11E+06 1.62E+05 7.15E+07 4.90E+04 3.43E+02 2.34E+06 1.51E+04 2.06E+03 0.133 0.155 0.948 2.839 P323 Position #27 CTMT AUX Grouted 5.31E+06 2.09E+05 9.24E+07 6.34E+04 4.43E+02 3.02E+06 1.95E+04 2.66E+03 0.171 0.201 1.225 3.668 P323 Position #28 CTMT AUX Grouted 4.62E+06 1.82E+05 8.03E+07 5.51E+04 3.85E+02 2.62E+06 1.69E+04 2.31E+03 0.149 0.175 1.065 3.189 P323 Position #29 CTMT AUX Grouted 4.59E+06 1.81E+05 7.98E+07 5.48E+04 3.83E+02 2.61E+06 1.68E+04 2.30E+03 0.148 0.174 1.058 3.170 P323 Position #30 CTMT AUX Grouted 4.00E+06 1.57E+05 6.96E+07 4.77E+04 3.34E+02 2.27E+06 1.47E+04 2.00E+03 0.129 0.151 0.923 2.763 P323 Position #31 CTMT AUX Grouted 3.78E+06 1.49E+05 6.57E+07 4.51E+04 3.15E+02 2.15E+06 1.39E+04 1.89E+03 0.122 0.143 0.872 2.611 P323 Position #32 CTMT AUX Grouted 3.79E+06 1.49E+05 6.58E+07 4.52E+04 3.16E+02 2.15E+06 1.39E+04 1.89E+03 0.122 0.143 0.873 2.615 P323 Position #33 CTMT AUX Grouted 3.79E+06 1.49E+05 6.59E+07 4.52E+04 3.16E+02 2.15E+06 1.39E+04 1.90E+03 0.122 0.143 0.874 2.617 P323 Position #34 CTMT AUX Grouted 3.80E+06 1.50E+05 6.61E+07 4.54E+04 3.17E+02 2.16E+06 1.39E+04 1.90E+03 0.123 0.144 0.877 2.625 P323 Position #35 CTMT AUX Grouted 4.15E+06 1.63E+05 7.21E+07 4.95E+04 3.46E+02 2.36E+06 1.52E+04 2.07E+03 0.134 0.157 0.956 2.864 P323 Position #36 CTMT AUX Grouted 5.16E+06 2.03E+05 8.98E+07 6.16E+04 4.30E+02 2.93E+06 1.89E+04 2.58E+03 0.167 0.195 1.191 3.566 P323 Position #37 CTMT AUX Grouted 4.33E+06 1.70E+05 7.52E+07 5.16E+04 3.61E+02 2.46E+06 1.59E+04 2.16E+03 0.140 0.164 0.998 2.988 P323 Position #38 CTMT AUX Grouted 4.18E+06 1.65E+05 7.27E+07 4.99E+04 3.49E+02 2.38E+06 1.53E+04 2.09E+03 0.135 0.158 0.965 2.889 P323 Position #39 CTMT AUX Grouted 3.98E+06 1.57E+05 6.92E+07 4.75E+04 3.32E+02 2.26E+06 1.46E+04 1.99E+03 0.128 0.150 0.917 2.747 P323 Position #40 CTMT AUX Grouted 3.99E+06 1.57E+05 6.94E+07 4.76E+04 3.33E+02 2.27E+06 1.46E+04 2.00E+03 0.129 0.151 0.921 2.757 P323 Position #41 CTMT AUX Grouted 4.09E+06 1.61E+05 7.10E+07 4.87E+04 3.41E+02 2.32E+06 1.50E+04 2.04E+03 0.132 0.155 0.942 2.821 P323 Position #42 CTMT AUX Grouted 4.09E+06 1.61E+05 7.10E+07 4.87E+04 3.41E+02 2.32E+06 1.50E+04 2.04E+03 0.132 0.155 0.942 2.821 P323 Position #43 CTMT AUX Grouted 4.14E+06 1.63E+05 7.19E+07 4.93E+04 3.45E+02 2.35E+06 1.52E+04 2.07E+03 0.133 0.156 0.954 2.856 P323 Position #44 CTMT AUX Grouted 4.27E+06 1.68E+05 7.43E+07 5.10E+04 3.56E+02 2.43E+06 1.57E+04 2.14E+03 0.138 0.162 0.985 2.951 P323 Position #45 CTMT AUX Grouted 4.53E+06 1.78E+05 7.88E+07 5.41E+04 3.78E+02 2.57E+06 1.66E+04 2.27E+03 0.146 0.171 1.045 3.128 P323 Position #46 CTMT AUX Grouted 6.59E+06 2.59E+05 1.15E+08 7.87E+04 5.50E+02 3.75E+06 2.42E+04 3.30E+03 0.213 0.249 1.521 4.554 P323 Position #47 CTMT AUX Grouted 6.41E+06 2.52E+05 1.11E+08 7.64E+04 5.34E+02 3.64E+06 2.35E+04 3.20E+03 0.207 0.242 1.477 4.425 P323 Position #48 CTMT AUX Grouted 5.33E+06 2.10E+05 9.27E+07 6.36E+04 4.44E+02 3.03E+06 1.95E+04 2.67E+03 0.172 0.202 1.229 3.680 P323 Position #49 CTMT AUX Grouted 5.09E+06 2.00E+05 8.84E+07 6.07E+04 4.24E+02 2.89E+06 1.87E+04 2.54E+03 0.164 0.192 1.173 3.513 P323 Position #50 CTMT AUX Grouted 5.58E+06 2.20E+05 9.71E+07 6.66E+04 4.65E+02 3.17E+06 2.05E+04 2.79E+03 0.180 0.211 1.287 3.855 P323 Position #1 CTMT AUX Grouted 4.43E+06 1.74E+05 7.70E+07 5.28E+04 3.69E+02 2.52E+06 1.62E+04 2.21E+03 0.143 0.167 1.021 3.058 P324 Position #1 CTMT AUX Grouted 1.17E+07 4.62E+05 2.04E+08 1.40E+05 9.78E+02 6.67E+06 4.30E+04 5.87E+03 0.379 0.444 2.707 8.106 P324 Position #2 CTMT AUX Grouted 5.31E+06 2.09E+05 9.24E+07 6.34E+04 4.43E+02 3.02E+06 1.95E+04 2.66E+03 0.171 0.201 1.225 3.668 P324 Position #3 CTMT AUX Grouted 4.22E+06 1.66E+05 7.33E+07 5.03E+04 3.51E+02 2.40E+06 1.55E+04 2.11E+03 0.136 0.159 0.972 2.911 P324 Position #4 CTMT AUX Grouted 4.34E+06 1.71E+05 7.54E+07 5.18E+04 3.62E+02 2.47E+06 1.59E+04 2.17E+03 0.140 0.164 1.001 2.996 P324 Position #5 CTMT AUX Grouted 4.30E+06 1.69E+05 7.47E+07 5.13E+04 3.58E+02 2.44E+06 1.58E+04 2.15E+03 0.139 0.163 0.991 2.967 P324 Position #6 CTMT AUX Grouted 4.13E+06 1.62E+05 7.18E+07 4.92E+04 3.44E+02 2.35E+06 1.51E+04 2.06E+03 0.133 0.156 0.952 2.850 P324 Position #7 CTMT AUX Grouted 4.04E+06 1.59E+05 7.03E+07 4.82E+04 3.37E+02 2.30E+06 1.48E+04 2.02E+03 0.130 0.153 0.932 2.792 P324 Position #8 CTMT AUX Grouted 4.29E+06 1.69E+05 7.45E+07 5.12E+04 3.57E+02 2.44E+06 1.57E+04 2.14E+03 0.138 0.162 0.989 2.961 P324 Position #9 CTMT AUX Grouted 4.59E+06 1.80E+05 7.97E+07 5.47E+04 3.82E+02 2.61E+06 1.68E+04 2.29E+03 0.148 0.173 1.058 3.167 P324 Position #10 CTMT AUX Grouted 4.17E+06 1.64E+05 7.24E+07 4.97E+04 3.47E+02 2.37E+06 1.53E+04 2.08E+03 0.134 0.158 0.961 2.877 P324 Position #11 CTMT AUX Grouted 3.98E+06 1.57E+05 6.92E+07 4.75E+04 3.32E+02 2.26E+06 1.46E+04 1.99E+03 0.128 0.151 0.918 2.748 P324 Position #12 CTMT AUX Grouted 4.09E+06 1.61E+05 7.10E+07 4.87E+04 3.41E+02 2.32E+06 1.50E+04 2.04E+03 0.132 0.155 0.942 2.821 P324 Position #13 CTMT AUX Grouted 4.03E+06 1.59E+05 7.01E+07 4.81E+04 3.36E+02 2.29E+06 1.48E+04 2.02E+03 0.130 0.153 0.930 2.786 P324 Position #14 CTMT AUX Grouted 4.09E+06 1.61E+05 7.11E+07 4.88E+04 3.41E+02 2.32E+06 1.50E+04 2.05E+03 0.132 0.155 0.943 2.825 P324 Position #15 CTMT AUX Grouted 4.13E+06 1.63E+05 7.19E+07 4.93E+04 3.45E+02 2.35E+06 1.52E+04 2.07E+03 0.133 0.156 0.953 2.855 P324 Position #16 CTMT AUX Grouted 4.22E+06 1.66E+05 7.34E+07 5.04E+04 3.52E+02 2.40E+06 1.55E+04 2.11E+03 0.136 0.160 0.974 2.916 P324 Position #17 CTMT AUX Grouted 4.85E+06 1.91E+05 8.43E+07 5.79E+04 4.04E+02 2.76E+06 1.78E+04 2.43E+03 0.157 0.183 1.118 3.350 P324 Position #18 CTMT AUX Grouted 5.13E+06 2.02E+05 8.93E+07 6.13E+04 4.28E+02 2.92E+06 1.88E+04 2.57E+03 0.166 0.194 1.184 3.546 P324 Position #19 CTMT AUX Grouted 4.41E+06 1.74E+05 7.68E+07 5.27E+04 3.68E+02 2.51E+06 1.62E+04 2.21E+03 0.142 0.167 1.018 3.049 P324 Position #20 CTMT AUX Grouted 4.23E+06 1.66E+05 7.35E+07 5.04E+04 3.52E+02 2.40E+06 1.55E+04 2.11E+03 0.136 0.160 0.975 2.920 P324 Position #21 CTMT AUX Grouted 4.49E+06 1.77E+05 7.80E+07 5.36E+04 3.74E+02 2.55E+06 1.65E+04 2.24E+03 0.145 0.170 1.035 3.100 P324 Position #22 CTMT AUX Grouted 4.16E+06 1.64E+05 7.24E+07 4.97E+04 3.47E+02 2.36E+06 1.53E+04 2.08E+03 0.134 0.157 0.960 2.874 P324 Position #23 CTMT AUX Grouted 3.73E+06 1.47E+05 6.49E+07 4.45E+04 3.11E+02 2.12E+06 1.37E+04 1.87E+03 0.120 0.141 0.860 2.576 MEASUREMENT ID BETWEEN END STATE
~
=ZIONSOLUTIONSuc-An Er,e,,gyS~ Company
FSS RELEASE RECORD, REV 1 PENETRATIONS SURVEY UNITS 01112, 02112 and 05120
[96]
Auxiliary Building Penetration Measurements (continued)
H-3 (1)
Co-60 (2)
Ni-63 (1)
Sr-90 (1)
Cs-134 (2)
Cs-137 (2)
Eu-152 (2)
Eu-154 (2)
OpSOFPN OpSOFPN OpSOFB OpSOFB (pCi/m2)
(pCi/m2)
(pCi/m2)
(pCi/m2)
(pCi/m2)
(pCi/m2)
(pCi/m2)
(pCi/m2)
CTMTPN Limiting DCGL CTMT/AB DCGL Limiting DCGL P324 Position #24 CTMT AUX Grouted 3.69E+06 1.45E+05 6.41E+07 4.40E+04 3.07E+02 2.10E+06 1.35E+04 1.84E+03 0.119 0.140 0.851 2.547 P324 Position #25 CTMT AUX Grouted 3.67E+06 1.44E+05 6.38E+07 4.38E+04 3.06E+02 2.08E+06 1.35E+04 1.83E+03 0.118 0.139 0.846 2.533 P324 Position #26 CTMT AUX Grouted 5.00E+06 1.97E+05 8.70E+07 5.97E+04 4.17E+02 2.84E+06 1.84E+04 2.50E+03 0.161 0.189 1.154 3.456 P324 Position #27 CTMT AUX Grouted 6.30E+06 2.48E+05 1.10E+08 7.52E+04 5.25E+02 3.58E+06 2.31E+04 3.15E+03 0.203 0.238 1.453 4.351 P324 Position #28 CTMT AUX Grouted 4.13E+06 1.63E+05 7.18E+07 4.93E+04 3.44E+02 2.35E+06 1.52E+04 2.07E+03 0.133 0.156 0.953 2.854 P324 Position #29 CTMT AUX Grouted 3.71E+06 1.46E+05 6.45E+07 4.42E+04 3.09E+02 2.11E+06 1.36E+04 1.85E+03 0.120 0.140 0.855 2.561 P324 Position #30 CTMT AUX Grouted 3.63E+06 1.43E+05 6.31E+07 4.33E+04 3.02E+02 2.06E+06 1.33E+04 1.81E+03 0.117 0.137 0.837 2.506 P324 Position #31 CTMT AUX Grouted 3.53E+06 1.39E+05 6.14E+07 4.21E+04 2.94E+02 2.01E+06 1.30E+04 1.77E+03 0.114 0.134 0.815 2.439 P324 Position #32 CTMT AUX Grouted 3.59E+06 1.41E+05 6.24E+07 4.28E+04 2.99E+02 2.04E+06 1.32E+04 1.79E+03 0.116 0.136 0.827 2.478 P324 Position #33 CTMT AUX Grouted 3.73E+06 1.47E+05 6.48E+07 4.45E+04 3.11E+02 2.12E+06 1.37E+04 1.86E+03 0.120 0.141 0.860 2.575 P324 Position #34 CTMT AUX Grouted 4.21E+06 1.65E+05 7.31E+07 5.02E+04 3.51E+02 2.39E+06 1.54E+04 2.10E+03 0.136 0.159 0.970 2.905 P324 Position #35 CTMT AUX Grouted 6.98E+06 2.74E+05 1.21E+08 8.32E+04 5.81E+02 3.96E+06 2.56E+04 3.49E+03 0.225 0.264 1.609 4.817 P324 Position #36 CTMT AUX Grouted 8.05E+06 3.17E+05 1.40E+08 9.61E+04 6.71E+02 4.57E+06 2.95E+04 4.03E+03 0.260 0.305 1.856 5.559 P324 Position #37 CTMT AUX Grouted 6.37E+06 2.51E+05 1.11E+08 7.61E+04 5.31E+02 3.62E+06 2.34E+04 3.19E+03 0.206 0.241 1.470 4.402 P324 Position #38 CTMT AUX Grouted 4.67E+06 1.84E+05 8.12E+07 5.57E+04 3.89E+02 2.65E+06 1.71E+04 2.33E+03 0.151 0.177 1.077 3.224 P324 Position #39 CTMT AUX Grouted 4.13E+06 1.62E+05 7.18E+07 4.92E+04 3.44E+02 2.35E+06 1.51E+04 2.06E+03 0.133 0.156 0.952 2.850 P324 Position #40 CTMT AUX Grouted 3.76E+06 1.48E+05 6.55E+07 4.49E+04 3.14E+02 2.14E+06 1.38E+04 1.88E+03 0.121 0.142 0.868 2.600 P324 Position #41 CTMT AUX Grouted 3.69E+06 1.45E+05 6.42E+07 4.41E+04 3.08E+02 2.10E+06 1.35E+04 1.85E+03 0.119 0.140 0.852 2.551 P324 Position #42 CTMT AUX Grouted 3.72E+06 1.46E+05 6.47E+07 4.44E+04 3.10E+02 2.12E+06 1.37E+04 1.86E+03 0.120 0.141 0.859 2.571 P324 Position #43 CTMT AUX Grouted 4.20E+06 1.65E+05 7.30E+07 5.01E+04 3.50E+02 2.39E+06 1.54E+04 2.10E+03 0.136 0.159 0.969 2.901 P324 Position #44 CTMT AUX Grouted 7.17E+06 2.82E+05 1.25E+08 8.55E+04 5.97E+02 4.07E+06 2.63E+04 3.58E+03 0.231 0.271 1.653 4.950 P324 Position #45 CTMT AUX Grouted 6.00E+06 2.36E+05 1.04E+08 7.16E+04 5.00E+02 3.41E+06 2.20E+04 3.00E+03 0.193 0.227 1.383 4.141 P324 Position #46 CTMT AUX Grouted 4.43E+06 1.74E+05 7.70E+07 5.28E+04 3.69E+02 2.51E+06 1.62E+04 2.21E+03 0.143 0.167 1.021 3.056 P324 Position #47 CTMT AUX Grouted 4.34E+06 1.71E+05 7.54E+07 5.17E+04 3.61E+02 2.46E+06 1.59E+04 2.17E+03 0.140 0.164 1.000 2.994 P324 Position #48 CTMT AUX Grouted 4.74E+06 1.86E+05 8.24E+07 5.65E+04 3.95E+02 2.69E+06 1.74E+04 2.37E+03 0.153 0.179 1.092 3.271 P324 Position #49 CTMT AUX Grouted 5.99E+06 2.36E+05 1.04E+08 7.15E+04 4.99E+02 3.40E+06 2.20E+04 2.99E+03 0.193 0.227 1.381 4.136 P324 Position #50 CTMT AUX Grouted 5.70E+06 2.24E+05 9.91E+07 6.80E+04 4.75E+02 3.24E+06 2.09E+04 2.85E+03 0.184 0.216 1.314 3.936 P220 By Direct Scan CTMT AUX Removed 7.07E+04 2.78E+03 1.23E+06 8.43E+02 5.89E+00 4.02E+04 2.59E+02 3.53E+01 0.002 0.003 0.016 0.049 A007 Position#1 AUX TB Open/Buried 0.00E+00 4.84E+03 8.74E+05 7.93E+02 5.27E+01 3.97E+05 0.00E+00 0.00E+00 0.009 0.012 0.012 0.239 A007 Position#2 AUX TB Open/Buried 0.00E+00 4.96E+03 8.96E+05 8.13E+02 5.40E+01 4.06E+05 0.00E+00 0.00E+00 0.010 0.012 0.012 0.245 A007 Position#3 AUX TB Open/Buried 0.00E+00 5.15E+03 9.30E+05 8.44E+02 5.60E+01 4.22E+05 0.00E+00 0.00E+00 0.010 0.013 0.012 0.254 A008 Position#1 AUX TB Open/Buried 0.00E+00 6.29E+03 1.14E+06 1.03E+03 6.84E+01 5.15E+05 0.00E+00 0.00E+00 0.012 0.015 0.015 0.311 A008 Position#2 AUX TB Open/Buried 0.00E+00 5.76E+03 1.04E+06 9.43E+02 6.26E+01 4.72E+05 0.00E+00 0.00E+00 0.011 0.014 0.014 0.284 A008 Position#3 AUX TB Open/Buried 0.00E+00 5.70E+03 1.03E+06 9.33E+02 6.20E+01 4.67E+05 0.00E+00 0.00E+00 0.011 0.014 0.014 0.281 A009 Position#1 AUX TB Open/Buried 0.00E+00 5.30E+03 9.56E+05 8.67E+02 5.76E+01 4.34E+05 0.00E+00 0.00E+00 0.010 0.013 0.013 0.262 A009 Position#2 AUX TB Open/Buried 0.00E+00 5.17E+03 9.32E+05 8.46E+02 5.61E+01 4.23E+05 0.00E+00 0.00E+00 0.010 0.013 0.012 0.255 A009 Position#3 AUX TB Open/Buried 0.00E+00 5.28E+03 9.54E+05 8.65E+02 5.74E+01 4.33E+05 0.00E+00 0.00E+00 0.010 0.013 0.013 0.261 A002 Position#1 AUX TB Open/Buried 0.00E+00 5.21E+03 9.41E+05 8.54E+02 5.67E+01 4.27E+05 0.00E+00 0.00E+00 0.010 0.013 0.012 0.257 A002 Position#2 AUX TB Open/Buried 0.00E+00 4.92E+03 8.87E+05 8.05E+02 5.34E+01 4.02E+05 0.00E+00 0.00E+00 0.010 0.012 0.012 0.243 A002 Position#3 AUX TB Open/Buried 0.00E+00 6.19E+03 1.12E+06 1.01E+03 6.72E+01 5.06E+05 0.00E+00 0.00E+00 0.012 0.015 0.015 0.305 A003 Position#1 AUX TB Open/Buried 0.00E+00 6.82E+03 1.23E+06 1.12E+03 7.41E+01 5.58E+05 0.00E+00 0.00E+00 0.013 0.017 0.016 0.337 A003 Position#2 AUX TB Open/Buried 0.00E+00 7.39E+03 1.33E+06 1.21E+03 8.03E+01 6.05E+05 0.00E+00 0.00E+00 0.014 0.018 0.018 0.365 A003 Position#3 AUX TB Open/Buried 0.00E+00 1.72E+04 3.10E+06 2.81E+03 1.87E+02 1.41E+06 0.00E+00 0.00E+00 0.033 0.042 0.041 0.848 A013 Position#1 AUX TB Open/Buried 0.00E+00 7.93E+03 1.43E+06 1.30E+03 8.62E+01 6.49E+05 0.00E+00 0.00E+00 0.015 0.019 0.019 0.392 A013 Position#2 AUX TB Open/Buried 0.00E+00 8.30E+03 1.50E+06 1.36E+03 9.02E+01 6.80E+05 0.00E+00 0.00E+00 0.016 0.020 0.020 0.410 A013 Position#3 AUX TB Open/Buried 0.00E+00 8.53E+03 1.54E+06 1.40E+03 9.27E+01 6.98E+05 0.00E+00 0.00E+00 0.017 0.021 0.020 0.421 A011 Position#1 AUX TB Grouted 0.00E+00 1.25E+05 2.25E+07 2.04E+04 1.35E+03 1.02E+07 0.00E+00 0.00E+00 0.243 0.303 0.298 6.149 A011 Position#2 AUX TB Grouted 0.00E+00 1.43E+05 2.59E+07 2.35E+04 1.56E+03 1.17E+07 0.00E+00 0.00E+00 0.279 0.349 0.344 7.078 A011 Position#3 AUX TB Grouted 0.00E+00 1.21E+05 2.18E+07 1.98E+04 1.31E+03 9.88E+06 0.00E+00 0.00E+00 0.235 0.294 0.289 5.958 A012 Position#1 AUX TB Open/Buried 0.00E+00 5.44E+03 9.81E+05 8.91E+02 5.91E+01 4.45E+05 0.00E+00 0.00E+00 0.011 0.013 0.013 0.269 A012 Position#2 AUX TB Open/Buried 0.00E+00 5.50E+03 9.92E+05 9.00E+02 5.98E+01 4.50E+05 0.00E+00 0.00E+00 0.011 0.013 0.013 0.271 A012 Position#3 AUX TB Open/Buried 0.00E+00 7.01E+03 1.26E+06 1.15E+03 7.62E+01 5.74E+05 0.00E+00 0.00E+00 0.014 0.017 0.017 0.346 A019 Position#1 AUX TB Open/Buried 0.00E+00 4.75E+03 8.57E+05 7.78E+02 5.16E+01 3.89E+05 0.00E+00 0.00E+00 0.009 0.012 0.011 0.235 MEASUREMENT ID BETWEEN END STATE
~
=ZIONSOLUTIONSuc-An Er,e,,gyS~ Company I I I I I I I I I I I I I I
FSS RELEASE RECORD, REV 1 PENETRATIONS SURVEY UNITS 01112, 02112 and 05120
[97]
Auxiliary Building Penetration Measurements (continued)
H-3 (1)
Co-60 (2)
Ni-63 (1)
Sr-90 (1)
Cs-134 (2)
Cs-137 (2)
Eu-152 (2)
Eu-154 (2)
OpSOFPN OpSOFPN OpSOFB OpSOFB (pCi/m2)
(pCi/m2)
(pCi/m2)
(pCi/m2)
(pCi/m2)
(pCi/m2)
(pCi/m2)
(pCi/m2)
CTMTPN Limiting DCGL CTMT/AB DCGL Limiting DCGL A019 Position#2 AUX TB Open/Buried 0.00E+00 4.73E+03 8.53E+05 7.74E+02 5.14E+01 3.87E+05 0.00E+00 0.00E+00 0.009 0.012 0.011 0.233 A019 Position#3 AUX TB Open/Buried 0.00E+00 5.18E+03 9.34E+05 8.48E+02 5.63E+01 4.24E+05 0.00E+00 0.00E+00 0.010 0.013 0.012 0.256 A015 Position#1 AUX TB Open/Buried 0.00E+00 6.64E+03 1.20E+06 1.09E+03 7.22E+01 5.44E+05 0.00E+00 0.00E+00 0.013 0.016 0.016 0.328 A015 Position#2 AUX TB Open/Buried 0.00E+00 6.59E+03 1.19E+06 1.08E+03 7.16E+01 5.40E+05 0.00E+00 0.00E+00 0.013 0.016 0.016 0.325 A015 Position#3 AUX TB Open/Buried 0.00E+00 7.55E+03 1.36E+06 1.24E+03 8.21E+01 6.18E+05 0.00E+00 0.00E+00 0.015 0.018 0.018 0.373 A005 Position#1 AUX TB Open/Buried 0.00E+00 4.51E+03 8.14E+05 7.39E+02 4.90E+01 3.69E+05 0.00E+00 0.00E+00 0.009 0.011 0.011 0.223 A005 Position#2 AUX TB Open/Buried 0.00E+00 4.50E+03 8.12E+05 7.37E+02 4.89E+01 3.68E+05 0.00E+00 0.00E+00 0.009 0.011 0.011 0.222 A005 Position#3 AUX TB Open/Buried 0.00E+00 5.07E+03 9.15E+05 8.30E+02 5.51E+01 4.15E+05 0.00E+00 0.00E+00 0.010 0.012 0.012 0.250 A020 Position#1 AUX TB Open/Buried 0.00E+00 5.13E+03 9.26E+05 8.40E+02 5.58E+01 4.20E+05 0.00E+00 0.00E+00 0.010 0.012 0.012 0.253 A020 Position#2 AUX TB Open/Buried 0.00E+00 5.98E+03 1.08E+06 9.80E+02 6.51E+01 4.90E+05 0.00E+00 0.00E+00 0.012 0.015 0.014 0.296 A020 Position#3 AUX TB Open/Buried 0.00E+00 5.95E+03 1.07E+06 9.74E+02 6.47E+01 4.87E+05 0.00E+00 0.00E+00 0.012 0.014 0.014 0.294 A021 Position#1 AUX TB Open/Buried 0.00E+00 6.67E+03 1.20E+06 1.09E+03 7.25E+01 5.46E+05 0.00E+00 0.00E+00 0.013 0.016 0.016 0.330 A021 Position#2 AUX TB Open/Buried 0.00E+00 5.59E+03 1.01E+06 9.16E+02 6.08E+01 4.58E+05 0.00E+00 0.00E+00 0.011 0.014 0.013 0.276 A021 Position#3 AUX TB Open/Buried 0.00E+00 5.63E+03 1.02E+06 9.22E+02 6.12E+01 4.61E+05 0.00E+00 0.00E+00 0.011 0.014 0.013 0.278 A022 Position#1 AUX TB Open/Buried 0.00E+00 4.44E+03 8.01E+05 7.27E+02 4.83E+01 3.64E+05 0.00E+00 0.00E+00 0.009 0.011 0.011 0.219 A022 Position#2 AUX TB Open/Buried 0.00E+00 4.46E+03 8.06E+05 7.31E+02 4.85E+01 3.66E+05 0.00E+00 0.00E+00 0.009 0.011 0.011 0.220 A022 Position#3 AUX TB Open/Buried 0.00E+00 6.03E+03 1.09E+06 9.88E+02 6.56E+01 4.94E+05 0.00E+00 0.00E+00 0.012 0.015 0.014 0.298 A023 Position#1 AUX TB Grouted 0.00E+00 6.23E+04 1.12E+07 1.02E+04 6.77E+02 5.10E+06 0.00E+00 0.00E+00 0.121 0.152 0.149 3.076 A023 Position#2 AUX TB Grouted 0.00E+00 8.47E+04 1.53E+07 1.39E+04 9.20E+02 6.93E+06 0.00E+00 0.00E+00 0.165 0.206 0.203 4.181 A023 Position#3 AUX TB Grouted 0.00E+00 6.52E+04 1.18E+07 1.07E+04 7.09E+02 5.34E+06 0.00E+00 0.00E+00 0.127 0.159 0.156 3.219 A017 Position#1 AUX TB Open/Buried 0.00E+00 9.91E+03 1.79E+06 1.62E+03 1.08E+02 8.11E+05 0.00E+00 0.00E+00 0.019 0.024 0.024 0.489 A017 Position#2 AUX TB Open/Buried 0.00E+00 1.07E+04 1.93E+06 1.75E+03 1.16E+02 8.74E+05 0.00E+00 0.00E+00 0.021 0.026 0.026 0.527 A017 Position#3 AUX TB Open/Buried 0.00E+00 1.29E+04 2.32E+06 2.11E+03 1.40E+02 1.05E+06 0.00E+00 0.00E+00 0.025 0.031 0.031 0.636 A010 Position#1 AUX TB Open/Buried 0.00E+00 8.41E+03 1.52E+06 1.38E+03 9.14E+01 6.89E+05 0.00E+00 0.00E+00 0.016 0.020 0.020 0.415 A010 Position#2 AUX TB Open/Buried 0.00E+00 8.59E+03 1.55E+06 1.41E+03 9.33E+01 7.03E+05 0.00E+00 0.00E+00 0.017 0.021 0.021 0.424 A010 Position#3 AUX TB Open/Buried 0.00E+00 1.01E+04 1.82E+06 1.65E+03 1.10E+02 8.25E+05 0.00E+00 0.00E+00 0.020 0.025 0.024 0.497 A001 Position #1 AUX TB Open/Buried 0.00E+00 4.20E+02 7.59E+04 6.88E+01 4.57E+00 3.44E+04 0.00E+00 0.00E+00 0.001 0.001 0.001 0.021 A001 Position #2 AUX TB Open/Buried 0.00E+00 4.61E+02 8.33E+04 7.56E+01 5.02E+00 3.78E+04 0.00E+00 0.00E+00 0.001 0.001 0.001 0.023 A001 Position #3 AUX TB Open/Buried 0.00E+00 4.37E+02 7.89E+04 7.16E+01 4.75E+00 3.58E+04 0.00E+00 0.00E+00 0.001 0.001 0.001 0.022 A014 Position #1 AUX TB Open/Buried 0.00E+00 2.71E+02 4.88E+04 4.43E+01 2.94E+00 2.22E+04 0.00E+00 0.00E+00 0.001 0.001 0.001 0.013 A014 Position #2 AUX TB Open/Buried 0.00E+00 3.53E+02 6.36E+04 5.78E+01 3.83E+00 2.89E+04 0.00E+00 0.00E+00 0.001 0.001 0.001 0.017 A014 Position #3 AUX TB Open/Buried 0.00E+00 4.06E+02 7.32E+04 6.65E+01 4.41E+00 3.32E+04 0.00E+00 0.00E+00 0.001 0.001 0.001 0.020 A004 Position #1 AUX TB Open/Buried 0.00E+00 3.79E+02 6.84E+04 6.21E+01 4.12E+00 3.11E+04 0.00E+00 0.00E+00 0.001 0.001 0.001 0.019 A004 Position #2 AUX TB Open/Buried 0.00E+00 3.38E+02 6.10E+04 5.54E+01 3.68E+00 2.77E+04 0.00E+00 0.00E+00 0.001 0.001 0.001 0.017 A004 Position #3 AUX TB Open/Buried 0.00E+00 4.32E+02 7.80E+04 7.08E+01 4.70E+00 3.54E+04 0.00E+00 0.00E+00 0.001 0.001 0.001 0.021 A024 Position #1 AUX TB Open/Buried 0.00E+00 4.49E+02 8.11E+04 7.36E+01 4.88E+00 3.68E+04 0.00E+00 0.00E+00 0.001 0.001 0.001 0.022 A024 Position #2 AUX TB Open/Buried 0.00E+00 7.61E+02 1.37E+05 1.25E+02 8.27E+00 6.23E+04 0.00E+00 0.00E+00 0.001 0.002 0.002 0.038 A024 Position #3 AUX TB Open/Buried 0.00E+00 1.34E+03 2.42E+05 2.20E+02 1.46E+01 1.10E+05 0.00E+00 0.00E+00 0.003 0.003 0.003 0.066 A025 Position #1 AUX TB Open/Buried 0.00E+00 3.31E+02 5.97E+04 5.42E+01 3.60E+00 2.71E+04 0.00E+00 0.00E+00 0.001 0.001 0.001 0.016 A025 Position #2 AUX TB Open/Buried 0.00E+00 3.14E+02 5.67E+04 5.14E+01 3.41E+00 2.57E+04 0.00E+00 0.00E+00 0.001 0.001 0.001 0.016 A025 Position #3 AUX TB Open/Buried 0.00E+00 3.55E+02 6.41E+04 5.81E+01 3.86E+00 2.91E+04 0.00E+00 0.00E+00 0.001 0.001 0.001 0.018 MEASUREMENT ID BETWEEN END STATE
~
=ZIONSOLUTIONSuc-An Er,e,,gyS~ Company
FSS RELEASE RECORD, REV 1 PENETRATIONS SURVEY UNITS 01112, 02112 and 05120
[98]
Auxiliary Building - Elevated Measurement Calculation Survey Unit Area 948.750 m2 (LTP Ch 6 Table 6-50, Release Record Table 1)
Elevated Area 0.559 m2 (FOV of Detector in Pipe at 1 ft increments)
H-3 Co-60 Ni-63 Sr-90 Cs-134 Cs-137 Eu-152 Eu-154 (pCi/m2)
(pCi/m2)
(pCi/m2)
(pCi/m2)
(pCi/m2)
(pCi/m2)
(pCi/m2)
(pCi/m2)
P123 Position #1 CTMT AUX Grouted 2.13E+08 8.37E+06 3.70E+09 2.54E+06 1.77E+04 1.21E+08 7.80E+05 1.06E+05 ABPN DCGLs 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 LimitingPN DCGLs 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 P123 Position #2 CTMT AUX Grouted 2.42E+08 9.53E+06 4.21E+09 2.89E+06 2.02E+04 1.38E+08 8.89E+05 1.21E+05 ABPN DCGLs 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 LimitingPN DCGLs 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 P123 Position #3 CTMT AUX Grouted 2.67E+08 1.05E+07 4.63E+09 3.18E+06 2.22E+04 1.51E+08 9.77E+05 1.33E+05 ABPN DCGLs 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 LimitingPN DCGLs 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 P123 Position #4 CTMT AUX Grouted 2.58E+08 1.01E+07 4.48E+09 3.07E+06 2.15E+04 1.46E+08 9.44E+05 1.29E+05 ABPN DCGLs 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 LimitingPN DCGLs 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 P123 Position #5 CTMT AUX Grouted 2.37E+08 9.31E+06 4.11E+09 2.82E+06 1.97E+04 1.34E+08 8.68E+05 1.18E+05 ABPN DCGLs 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 LimitingPN DCGLs 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 P123 Position #6 CTMT AUX Grouted 2.10E+08 8.25E+06 3.65E+09 2.50E+06 1.75E+04 1.19E+08 7.69E+05 1.05E+05 ABPN DCGLs 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 LimitingPN DCGLs 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 P123 Position #7 CTMT AUX Grouted 1.96E+08 7.71E+06 3.41E+09 2.34E+06 1.63E+04 1.11E+08 7.18E+05 9.80E+04 ABPN DCGLs 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 LimitingPN DCGLs 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 P123 Position #8 CTMT AUX Grouted 1.83E+08 7.21E+06 3.19E+09 2.19E+06 1.53E+04 1.04E+08 6.72E+05 9.17E+04 ABPN DCGLs 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 LimitingPN DCGLs 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 P123 Position #9 CTMT AUX Grouted 1.73E+08 6.80E+06 3.01E+09 2.06E+06 1.44E+04 9.83E+07 6.34E+05 8.65E+04 ABPN DCGLs 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 LimitingPN DCGLs 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 P123 Position #10 CTMT AUX Grouted 1.84E+08 7.26E+06 3.21E+09 2.20E+06 1.54E+04 1.05E+08 6.76E+05 9.22E+04 ABPN DCGLs 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 LimitingPN DCGLs 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 P123 Position #11 CTMT AUX Grouted 1.93E+08 7.61E+06 3.36E+09 2.31E+06 1.61E+04 1.10E+08 7.10E+05 9.68E+04 ABPN DCGLs 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 LimitingPN DCGLs 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 ELEVATED MEASUREMENTS MEASUREMENT ID BETWEEN END STATE BcSOFADJ
~
=ZIONSOLUTIONSuc-An Er,e,,gyS~ Company
FSS RELEASE RECORD, REV 1 PENETRATIONS SURVEY UNITS 01112, 02112 and 05120
[99]
Auxiliary Building - Elevated Measurement Calculation (continued)
P123 Position #12 CTMT AUX Grouted 1.93E+08 7.60E+06 3.36E+09 2.30E+06 1.61E+04 1.10E+08 7.08E+05 9.66E+04 ABPN DCGLs 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 LimitingPN DCGLs 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 P123 Position #13 CTMT AUX Grouted 2.03E+08 7.99E+06 3.53E+09 2.42E+06 1.69E+04 1.15E+08 7.45E+05 1.02E+05 ABPN DCGLs 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 LimitingPN DCGLs 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 P123 Position #14 CTMT AUX Grouted 1.81E+08 7.13E+06 3.15E+09 2.16E+06 1.51E+04 1.03E+08 6.64E+05 9.06E+04 ABPN DCGLs 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 LimitingPN DCGLs 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 P123 Position #15 CTMT AUX Grouted 1.41E+08 5.54E+06 2.45E+09 1.68E+06 1.17E+04 8.00E+07 5.16E+05 7.04E+04 ABPN DCGLs 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 LimitingPN DCGLs 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 P123 Position #16 CTMT AUX Grouted 1.19E+08 4.68E+06 2.07E+09 1.42E+06 9.92E+03 6.76E+07 4.37E+05 5.95E+04 ABPN DCGLs 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 LimitingPN DCGLs 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 P123 Position #17 CTMT AUX Grouted 1.11E+08 4.37E+06 1.93E+09 1.32E+06 9.25E+03 6.31E+07 4.07E+05 5.55E+04 ABPN DCGLs 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 LimitingPN DCGLs 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 P123 Position #18 CTMT AUX Grouted 1.07E+08 4.21E+06 1.86E+09 1.28E+06 8.93E+03 6.09E+07 3.93E+05 5.36E+04 ABPN DCGLs 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 LimitingPN DCGLs 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 P123 Position #19 CTMT AUX Grouted 1.11E+08 4.35E+06 1.92E+09 1.32E+06 9.22E+03 6.29E+07 4.06E+05 5.53E+04 ABPN DCGLs 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 LimitingPN DCGLs 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 P123 Position #20 CTMT AUX Grouted 8.98E+07 3.53E+06 1.56E+09 1.07E+06 7.48E+03 5.10E+07 3.29E+05 4.49E+04 ABPN DCGLs 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 LimitingPN DCGLs 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 P123 Position #21 CTMT AUX Grouted 6.62E+07 2.61E+06 1.15E+09 7.90E+05 5.52E+03 3.76E+07 2.43E+05 3.31E+04 ABPN DCGLs 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 LimitingPN DCGLs 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 P123 Position #22 CTMT AUX Grouted 5.80E+07 2.28E+06 1.01E+09 6.92E+05 4.83E+03 3.29E+07 2.13E+05 2.90E+04 ABPN DCGLs 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 LimitingPN DCGLs 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 P123 Position #23 CTMT AUX Grouted 4.22E+07 1.66E+06 7.34E+08 5.04E+05 3.52E+03 2.40E+07 1.55E+05 2.11E+04 ABPN DCGLs 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 LimitingPN DCGLs 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 P124 Position #1 CTMT AUX Grouted 8.20E+07 3.23E+06 1.43E+09 9.79E+05 6.84E+03 4.66E+07 3.01E+05 4.10E+04 ABPN DCGLs 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 LimitingPN DCGLs 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
+
+
+
+
+
+
+
+
+
+
~
=ZIONSOLUTIONSuc-An Er,e,,gyS~ Company
FSS RELEASE RECORD, REV 1 PENETRATIONS SURVEY UNITS 01112, 02112 and 05120
[100]
Auxiliary Building - Elevated Measurement Calculation (continued)
P124 Position #2 CTMT AUX Grouted 6.80E+07 2.68E+06 1.18E+09 8.11E+05 5.67E+03 3.86E+07 2.49E+05 3.40E+04 ABPN DCGLs 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 LimitingPN DCGLs 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 P124 Position #3 CTMT AUX Grouted 7.10E+07 2.80E+06 1.24E+09 8.48E+05 5.92E+03 4.04E+07 2.61E+05 3.55E+04 ABPN DCGLs 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 LimitingPN DCGLs 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 P124 Position #4 CTMT AUX Grouted 7.18E+07 2.83E+06 1.25E+09 8.57E+05 5.99E+03 4.08E+07 2.63E+05 3.59E+04 ABPN DCGLs 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 LimitingPN DCGLs 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 P124 Position #5 CTMT AUX Grouted 7.08E+07 2.79E+06 1.23E+09 8.45E+05 5.90E+03 4.02E+07 2.60E+05 3.54E+04 ABPN DCGLs 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 LimitingPN DCGLs 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 P124 Position #6 CTMT AUX Grouted 6.72E+07 2.64E+06 1.17E+09 8.02E+05 5.60E+03 3.82E+07 2.46E+05 3.36E+04 ABPN DCGLs 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 LimitingPN DCGLs 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 P124 Position #7 CTMT AUX Grouted 5.96E+07 2.35E+06 1.04E+09 7.12E+05 4.97E+03 3.39E+07 2.19E+05 2.98E+04 ABPN DCGLs 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 LimitingPN DCGLs 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 P124 Position #8 CTMT AUX Grouted 5.76E+07 2.27E+06 1.00E+09 6.87E+05 4.80E+03 3.27E+07 2.11E+05 2.88E+04 ABPN DCGLs 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 LimitingPN DCGLs 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 P124 Position #9 CTMT AUX Grouted 5.79E+07 2.28E+06 1.01E+09 6.91E+05 4.83E+03 3.29E+07 2.12E+05 2.90E+04 ABPN DCGLs 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 LimitingPN DCGLs 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 P124 Position #10 CTMT AUX Grouted 5.90E+07 2.32E+06 1.03E+09 7.04E+05 4.92E+03 3.35E+07 2.16E+05 2.95E+04 ABPN DCGLs 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 LimitingPN DCGLs 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 P124 Position #11 CTMT AUX Grouted 6.11E+07 2.40E+06 1.06E+09 7.29E+05 5.09E+03 3.47E+07 2.24E+05 3.05E+04 ABPN DCGLs 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 LimitingPN DCGLs 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 P124 Position #12 CTMT AUX Grouted 6.22E+07 2.45E+06 1.08E+09 7.42E+05 5.18E+03 3.53E+07 2.28E+05 3.11E+04 ABPN DCGLs 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 LimitingPN DCGLs 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 P124 Position #13 CTMT AUX Grouted 6.30E+07 2.48E+06 1.09E+09 7.51E+05 5.25E+03 3.58E+07 2.31E+05 3.15E+04 ABPN DCGLs 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 LimitingPN DCGLs 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 P124 Position #14 CTMT AUX Grouted 6.56E+07 2.58E+06 1.14E+09 7.82E+05 5.47E+03 3.73E+07 2.40E+05 3.28E+04 ABPN DCGLs 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 LimitingPN DCGLs 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
~
= ZIONSOLUTIONSuc-An Er,e,,gyS~ Company I
+
I
+
+
I
+
f
+
I I
I I
I I
I
+
I
+
+
I
+
I
+
I
+
+
I
+
+
+
FSS RELEASE RECORD, REV 1 PENETRATIONS SURVEY UNITS 01112, 02112 and 05120
[101]
Auxiliary Building - Elevated Measurement Calculation (continued)
Auxiliary Building - Elevated Measurement Calculation LTP Chapter 5, Equation 5-6 P124 Position #15 CTMT AUX Grouted 6.30E+07 2.48E+06 1.10E+09 7.52E+05 5.25E+03 3.58E+07 2.31E+05 3.15E+04 ABPN DCGLs 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 LimitingPN DCGLs 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 P124 Position #16 CTMT AUX Grouted 5.04E+07 1.98E+06 8.76E+08 6.01E+05 4.20E+03 2.86E+07 1.85E+05 2.52E+04 ABPN DCGLs 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 LimitingPN DCGLs 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 P124 Position #17 CTMT AUX Grouted 4.42E+07 1.74E+06 7.69E+08 5.28E+05 3.69E+03 2.51E+07 1.62E+05 2.21E+04 ABPN DCGLs 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 LimitingPN DCGLs 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 P124 Position #18 CTMT AUX Grouted 4.10E+07 1.61E+06 7.13E+08 4.89E+05 3.42E+03 2.33E+07 1.50E+05 2.05E+04 ABPN DCGLs 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 LimitingPN DCGLs 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 P124 Position #19 CTMT AUX Grouted 3.55E+07 1.40E+06 6.17E+08 4.24E+05 2.96E+03 2.02E+07 1.30E+05 1.78E+04 ABPN DCGLs 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 LimitingPN DCGLs 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 P021 By Direct Scan CTMT AUX Removed 4.57E+07 1.80E+06 7.95E+08 5.45E+05 3.81E+03 2.60E+07 1.68E+05 2.29E+04 ABPN DCGLs 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 LimitingPN DCGLs 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
~
= ZIONSOLUTIONSuc-An Er,e,,gyS~
Company I
+
I I
I I
I I
I I
I I
l 11 Mean ConcEP/PN. (Elev ConcEP/PN. - Mean ConcEP/PN.)
MQ M Q M Q SOFEP/PN =
_B_D_C-GL ___ +
[
~SA
)]
i=l c
EP/PN ROCj BcDCGLEP/PN x A su ROq Elev
FSS RELEASE RECORD, REV 1 PENETRATIONS SURVEY UNITS 01112, 02112 and 05120
[102]
Turbine Building Penetration Measurements H-3 (1)
Co-60 (2)
Ni-63 (1)
Sr-90 (1)
Cs-134 (2)
Cs-137 (2)
Eu-152 (2)
Eu-154 (2)
OpSOFPN OpSOFPN OpSOFB OpSOFB (pCi/m2)
(pCi/m2)
(pCi/m2)
(pCi/m2)
(pCi/m2)
(pCi/m2)
(pCi/m2)
(pCi/m2)
ABPN Limiting DCGL AB DCGL Limiting DCGL P005 By Direct Scan CTMT TB Open/Buried 8.16E+04 3.21E+03 1.42E+06 9.73E+02 6.80E+00 4.64E+04 2.99E+02 4.08E+01 0.003 0.003 0.019 0.056 P009 By Direct Scan CTMT TB Open/Buried 8.75E+04 3.44E+03 1.52E+06 1.04E+03 7.29E+00 4.97E+04 3.21E+02 4.37E+01 0.003 0.003 0.020 0.060 P112 By Direct Scan CTMT TB Open/Buried 8.75E+04 3.44E+03 1.52E+06 1.04E+03 7.29E+00 4.97E+04 3.21E+02 4.37E+01 0.003 0.003 0.020 0.060 P094 By Direct Scan CTMT TB Open/Buried 9.01E+04 3.55E+03 1.57E+06 1.08E+03 7.51E+00 5.12E+04 3.31E+02 4.51E+01 0.003 0.003 0.021 0.062 P007 By Direct Scan CTMT TB Open/Buried 7.98E+04 3.14E+03 1.39E+06 9.52E+02 6.65E+00 4.53E+04 2.93E+02 3.99E+01 0.003 0.003 0.018 0.055 P007 By Direct Scan CTMT TB Open/Buried 3.68E+04 1.45E+03 6.40E+05 4.39E+02 3.07E+00 2.09E+04 1.35E+02 1.84E+01 0.001 0.001 0.008 0.025 P116 By Direct Scan CTMT TB Open/Buried 6.07E+04 2.39E+03 1.05E+06 7.24E+02 5.06E+00 3.45E+04 2.23E+02 3.03E+01 0.002 0.002 0.014 0.042 P011 By Direct Scan CTMT TB Open/Buried 4.09E+04 1.61E+03 7.12E+05 4.88E+02 3.41E+00 2.33E+04 1.50E+02 2.05E+01 0.001 0.002 0.009 0.028 P097 By Direct Scan CTMT TB Open/Buried 6.01E+04 2.36E+03 1.04E+06 7.17E+02 5.01E+00 3.41E+04 2.20E+02 3.00E+01 0.002 0.002 0.014 0.041 P128 By Direct Scan CTMT TB Open/Buried 7.30E+04 2.87E+03 1.27E+06 8.72E+02 6.09E+00 4.15E+04 2.68E+02 3.65E+01 0.002 0.003 0.017 0.050 P012 By Direct Scan CTMT TB Open/Buried 2.09E+05 8.24E+03 3.64E+06 2.50E+03 1.75E+01 1.19E+05 7.68E+02 1.05E+02 0.007 0.008 0.048 0.145 P008 By Direct Scan CTMT TB Open/Buried 1.19E+05 4.68E+03 2.07E+06 1.42E+03 9.92E+00 6.76E+04 4.36E+02 5.95E+01 0.004 0.005 0.027 0.082 P117 By Direct Scan CTMT TB Open/Buried 7.04E+04 2.77E+03 1.22E+06 8.40E+02 5.87E+00 4.00E+04 2.58E+02 3.52E+01 0.002 0.003 0.016 0.049 P113 By Direct Scan CTMT TB Open/Buried 5.04E+04 1.98E+03 8.76E+05 6.01E+02 4.20E+00 2.86E+04 1.85E+02 2.52E+01 0.002 0.002 0.012 0.035 P115 By Direct Scan CTMT TB Open/Buried 1.24E+05 4.87E+03 2.15E+06 1.48E+03 1.03E+01 7.03E+04 4.54E+02 6.19E+01 0.004 0.005 0.029 0.085 P093 By Direct Scan CTMT TB Open/Buried 1.70E+05 6.70E+03 2.96E+06 2.03E+03 1.42E+01 9.67E+04 6.24E+02 8.51E+01 0.005 0.006 0.039 0.118 P006 By Direct Scan CTMT TB Open/Buried 1.17E+05 4.59E+03 2.03E+06 1.39E+03 9.72E+00 6.63E+04 4.28E+02 5.83E+01 0.004 0.004 0.027 0.081 P096 By Direct Scan CTMT TB Open/Buried 6.98E+04 2.75E+03 1.21E+06 8.33E+02 5.82E+00 3.97E+04 2.56E+02 3.49E+01 0.002 0.003 0.016 0.048 P010 By Direct Scan CTMT TB Open/Buried 1.05E+05 4.14E+03 1.83E+06 1.25E+03 8.76E+00 5.97E+04 3.86E+02 5.26E+01 0.003 0.004 0.024 0.073 P095 By Direct Scan CTMT TB Open/Buried 6.10E+04 2.40E+03 1.06E+06 7.27E+02 5.08E+00 3.46E+04 2.24E+02 3.05E+01 0.002 0.002 0.014 0.042 P127 By Direct Scan CTMT TB Open/Buried 1.08E+05 4.25E+03 1.88E+06 1.29E+03 9.01E+00 6.14E+04 3.96E+02 5.41E+01 0.003 0.004 0.025 0.075 P092 By Direct Scan CTMT TB Open/Buried 6.07E+04 2.39E+03 1.05E+06 7.24E+02 5.06E+00 3.45E+04 2.23E+02 3.03E+01 0.002 0.002 0.014 0.042 P091 By Direct Scan CTMT TB Open/Buried 7.36E+04 2.90E+03 1.28E+06 8.79E+02 6.14E+00 4.18E+04 2.70E+02 3.68E+01 0.002 0.003 0.017 0.051 P098 By Direct Scan CTMT TB Open/Buried 6.33E+04 2.49E+03 1.10E+06 7.56E+02 5.28E+00 3.60E+04 2.32E+02 3.17E+01 0.002 0.002 0.015 0.044 P118 By Direct Scan CTMT TB Open/Buried 6.39E+04 2.51E+03 1.11E+06 7.63E+02 5.33E+00 3.63E+04 2.34E+02 3.20E+01 0.002 0.002 0.015 0.044 P292 By Direct Scan CTMT TB Open/Buried 9.54E+04 3.75E+03 1.66E+06 1.14E+03 7.95E+00 5.42E+04 3.50E+02 4.77E+01 0.003 0.004 0.022 0.066 P209 By Direct Scan CTMT TB Open/Buried 1.34E+05 5.26E+03 2.33E+06 1.60E+03 1.11E+01 7.60E+04 4.90E+02 6.69E+01 0.004 0.005 0.031 0.092 P205 By Direct Scan CTMT TB Open/Buried 2.00E+05 7.87E+03 3.48E+06 2.39E+03 1.67E+01 1.14E+05 7.33E+02 1.00E+02 0.006 0.008 0.046 0.138 P205 By Direct Scan CTMT TB Open/Buried 1.93E+05 7.58E+03 3.35E+06 2.30E+03 1.61E+01 1.09E+05 7.06E+02 9.63E+01 0.006 0.007 0.044 0.133 P327 By Direct Scan CTMT TB Open/Buried 1.09E+05 4.30E+03 1.90E+06 1.30E+03 9.11E+00 6.21E+04 4.01E+02 5.46E+01 0.004 0.004 0.025 0.075 P211 By Direct Scan CTMT TB Open/Buried 1.27E+05 5.01E+03 2.21E+06 1.52E+03 1.06E+01 7.23E+04 4.67E+02 6.36E+01 0.004 0.005 0.029 0.088 P315 By Direct Scan CTMT TB Open/Buried 6.86E+04 2.70E+03 1.19E+06 8.19E+02 5.72E+00 3.90E+04 2.52E+02 3.43E+01 0.002 0.003 0.016 0.047 P207 By Direct Scan CTMT TB Open/Buried 4.98E+04 1.96E+03 8.65E+05 5.94E+02 4.15E+00 2.83E+04 1.83E+02 2.49E+01 0.002 0.002 0.011 0.034 P296 By Direct Scan CTMT TB Open/Buried 6.74E+04 2.65E+03 1.17E+06 8.05E+02 5.62E+00 3.83E+04 2.47E+02 3.37E+01 0.002 0.003 0.016 0.047 P208 By Direct Scan CTMT TB Open/Buried 4.68E+04 1.84E+03 8.13E+05 5.58E+02 3.90E+00 2.66E+04 1.71E+02 2.34E+01 0.002 0.002 0.011 0.032 P318 By Direct Scan CTMT TB Open/Buried 5.78E+04 2.27E+03 1.01E+06 6.90E+02 4.82E+00 3.28E+04 2.12E+02 2.89E+01 0.002 0.002 0.013 0.040 P317 By Direct Scan CTMT TB Open/Buried 5.23E+04 2.06E+03 9.09E+05 6.24E+02 4.36E+00 2.97E+04 1.92E+02 2.61E+01 0.002 0.002 0.012 0.036 P212 By Direct Scan CTMT TB Open/Buried 6.04E+04 2.38E+03 1.05E+06 7.20E+02 5.03E+00 3.43E+04 2.21E+02 3.02E+01 0.002 0.002 0.014 0.042 P298 By Direct Scan CTMT TB Open/Buried 4.49E+04 1.77E+03 7.81E+05 5.36E+02 3.74E+00 2.55E+04 1.65E+02 2.25E+01 0.001 0.002 0.010 0.031 P313 By Direct Scan CTMT TB Open/Buried 4.23E+04 1.67E+03 7.36E+05 5.05E+02 3.53E+00 2.41E+04 1.55E+02 2.12E+01 0.001 0.002 0.010 0.029 P297 By Direct Scan CTMT TB Open/Buried 4.23E+04 1.67E+03 7.36E+05 5.05E+02 3.53E+00 2.41E+04 1.55E+02 2.12E+01 0.001 0.002 0.010 0.029 P328 By Direct Scan CTMT TB Open/Buried 4.68E+04 1.84E+03 8.13E+05 5.58E+02 3.90E+00 2.66E+04 1.71E+02 2.34E+01 0.002 0.002 0.011 0.032 P316 By Direct Scan CTMT TB Open/Buried 7.14E+04 2.81E+03 1.24E+06 8.52E+02 5.95E+00 4.06E+04 2.62E+02 3.57E+01 0.002 0.003 0.016 0.049 P294 By Direct Scan CTMT TB Open/Buried 3.94E+04 1.55E+03 6.85E+05 4.70E+02 3.28E+00 2.24E+04 1.44E+02 1.97E+01 0.001 0.001 0.009 0.027 P293 By Direct Scan CTMT TB Open/Buried 5.41E+04 2.13E+03 9.41E+05 6.46E+02 4.51E+00 3.07E+04 1.98E+02 2.71E+01 0.002 0.002 0.012 0.037 P210 By Direct Scan CTMT TB Open/Buried 1.31E+05 5.14E+03 2.27E+06 1.56E+03 1.09E+01 7.43E+04 4.79E+02 6.54E+01 0.004 0.005 0.030 0.090 P312 By Direct Scan CTMT TB Open/Buried 5.71E+04 2.24E+03 9.92E+05 6.81E+02 4.76E+00 3.24E+04 2.09E+02 2.85E+01 0.002 0.002 0.013 0.039 P295 By Direct Scan CTMT TB Open/Buried 5.60E+04 2.20E+03 9.73E+05 6.68E+02 4.66E+00 3.18E+04 2.05E+02 2.80E+01 0.002 0.002 0.013 0.039 P291 By Direct Scan CTMT TB Open/Buried 9.06E+04 3.56E+03 1.57E+06 1.08E+03 7.55E+00 5.15E+04 3.32E+02 4.53E+01 0.003 0.003 0.021 0.063 A007 Position#1 AUX TB Open/Buried 0.00E+00 4.84E+03 8.74E+05 7.93E+02 5.27E+01 3.97E+05 0.00E+00 0.00E+00 0.009 0.012 0.012 0.239 A007 Position#2 AUX TB Open/Buried 0.00E+00 4.96E+03 8.96E+05 8.13E+02 5.40E+01 4.06E+05 0.00E+00 0.00E+00 0.010 0.012 0.012 0.245 A007 Position#3 AUX TB Open/Buried 0.00E+00 5.15E+03 9.30E+05 8.44E+02 5.60E+01 4.22E+05 0.00E+00 0.00E+00 0.010 0.013 0.012 0.254 A008 Position#1 AUX TB Open/Buried 0.00E+00 6.29E+03 1.14E+06 1.03E+03 6.84E+01 5.15E+05 0.00E+00 0.00E+00 0.012 0.015 0.015 0.311 A008 Position#2 AUX TB Open/Buried 0.00E+00 5.76E+03 1.04E+06 9.43E+02 6.26E+01 4.72E+05 0.00E+00 0.00E+00 0.011 0.014 0.014 0.284 BETWEEN MEASUREMENT ID END STATE
~
=ZIONSOLUTIONSuc-An Er,e,,gyS~ Company
FSS RELEASE RECORD, REV 1 PENETRATIONS SURVEY UNITS 01112, 02112 and 05120
[103]
Turbine Building Penetration Measurements (continued)
H-3 (1)
Co-60 (2)
Ni-63 (1)
Sr-90 (1)
Cs-134 (2)
Cs-137 (2)
Eu-152 (2)
Eu-154 (2)
OpSOFPN OpSOFPN OpSOFB OpSOFB (pCi/m2)
(pCi/m2)
(pCi/m2)
(pCi/m2)
(pCi/m2)
(pCi/m2)
(pCi/m2)
(pCi/m2)
ABPN Limiting DCGL AB DCGL Limiting DCGL A008 Position#3 AUX TB Open/Buried 0.00E+00 5.70E+03 1.03E+06 9.33E+02 6.20E+01 4.67E+05 0.00E+00 0.00E+00 0.011 0.014 0.014 0.281 A009 Position#1 AUX TB Open/Buried 0.00E+00 5.30E+03 9.56E+05 8.67E+02 5.76E+01 4.34E+05 0.00E+00 0.00E+00 0.010 0.013 0.013 0.262 A009 Position#2 AUX TB Open/Buried 0.00E+00 5.17E+03 9.32E+05 8.46E+02 5.61E+01 4.23E+05 0.00E+00 0.00E+00 0.010 0.013 0.012 0.255 A009 Position#3 AUX TB Open/Buried 0.00E+00 5.28E+03 9.54E+05 8.65E+02 5.74E+01 4.33E+05 0.00E+00 0.00E+00 0.010 0.013 0.013 0.261 A002 Position#1 AUX TB Open/Buried 0.00E+00 5.21E+03 9.41E+05 8.54E+02 5.67E+01 4.27E+05 0.00E+00 0.00E+00 0.010 0.013 0.012 0.257 A002 Position#2 AUX TB Open/Buried 0.00E+00 4.92E+03 8.87E+05 8.05E+02 5.34E+01 4.02E+05 0.00E+00 0.00E+00 0.010 0.012 0.012 0.243 A002 Position#3 AUX TB Open/Buried 0.00E+00 6.19E+03 1.12E+06 1.01E+03 6.72E+01 5.06E+05 0.00E+00 0.00E+00 0.012 0.015 0.015 0.305 A003 Position#1 AUX TB Open/Buried 0.00E+00 6.82E+03 1.23E+06 1.12E+03 7.41E+01 5.58E+05 0.00E+00 0.00E+00 0.013 0.017 0.016 0.337 A003 Position#2 AUX TB Open/Buried 0.00E+00 7.39E+03 1.33E+06 1.21E+03 8.03E+01 6.05E+05 0.00E+00 0.00E+00 0.014 0.018 0.018 0.365 A003 Position#3 AUX TB Open/Buried 0.00E+00 1.72E+04 3.10E+06 2.81E+03 1.87E+02 1.41E+06 0.00E+00 0.00E+00 0.033 0.042 0.041 0.848 A013 Position#1 AUX TB Open/Buried 0.00E+00 7.93E+03 1.43E+06 1.30E+03 8.62E+01 6.49E+05 0.00E+00 0.00E+00 0.015 0.019 0.019 0.392 A013 Position#2 AUX TB Open/Buried 0.00E+00 8.30E+03 1.50E+06 1.36E+03 9.02E+01 6.80E+05 0.00E+00 0.00E+00 0.016 0.020 0.020 0.410 A013 Position#3 AUX TB Open/Buried 0.00E+00 8.53E+03 1.54E+06 1.40E+03 9.27E+01 6.98E+05 0.00E+00 0.00E+00 0.017 0.021 0.020 0.421 A011 Position#1 AUX TB Grouted 0.00E+00 1.25E+05 2.25E+07 2.04E+04 1.35E+03 1.02E+07 0.00E+00 0.00E+00 0.243 0.303 0.298 6.149 A011 Position#2 AUX TB Grouted 0.00E+00 1.43E+05 2.59E+07 2.35E+04 1.56E+03 1.17E+07 0.00E+00 0.00E+00 0.279 0.349 0.344 7.078 A011 Position#3 AUX TB Grouted 0.00E+00 1.21E+05 2.18E+07 1.98E+04 1.31E+03 9.88E+06 0.00E+00 0.00E+00 0.235 0.294 0.289 5.958 A012 Position#1 AUX TB Open/Buried 0.00E+00 5.44E+03 9.81E+05 8.91E+02 5.91E+01 4.45E+05 0.00E+00 0.00E+00 0.011 0.013 0.013 0.269 A012 Position#2 AUX TB Open/Buried 0.00E+00 5.50E+03 9.92E+05 9.00E+02 5.98E+01 4.50E+05 0.00E+00 0.00E+00 0.011 0.013 0.013 0.271 A012 Position#3 AUX TB Open/Buried 0.00E+00 7.01E+03 1.26E+06 1.15E+03 7.62E+01 5.74E+05 0.00E+00 0.00E+00 0.014 0.017 0.017 0.346 A019 Position#1 AUX TB Open/Buried 0.00E+00 4.75E+03 8.57E+05 7.78E+02 5.16E+01 3.89E+05 0.00E+00 0.00E+00 0.009 0.012 0.011 0.235 A019 Position#2 AUX TB Open/Buried 0.00E+00 4.73E+03 8.53E+05 7.74E+02 5.14E+01 3.87E+05 0.00E+00 0.00E+00 0.009 0.012 0.011 0.233 A019 Position#3 AUX TB Open/Buried 0.00E+00 5.18E+03 9.34E+05 8.48E+02 5.63E+01 4.24E+05 0.00E+00 0.00E+00 0.010 0.013 0.012 0.256 A015 Position#1 AUX TB Open/Buried 0.00E+00 6.64E+03 1.20E+06 1.09E+03 7.22E+01 5.44E+05 0.00E+00 0.00E+00 0.013 0.016 0.016 0.328 A015 Position#2 AUX TB Open/Buried 0.00E+00 6.59E+03 1.19E+06 1.08E+03 7.16E+01 5.40E+05 0.00E+00 0.00E+00 0.013 0.016 0.016 0.325 A015 Position#3 AUX TB Open/Buried 0.00E+00 7.55E+03 1.36E+06 1.24E+03 8.21E+01 6.18E+05 0.00E+00 0.00E+00 0.015 0.018 0.018 0.373 A005 Position#1 AUX TB Open/Buried 0.00E+00 4.51E+03 8.14E+05 7.39E+02 4.90E+01 3.69E+05 0.00E+00 0.00E+00 0.009 0.011 0.011 0.223 A005 Position#2 AUX TB Open/Buried 0.00E+00 4.50E+03 8.12E+05 7.37E+02 4.89E+01 3.68E+05 0.00E+00 0.00E+00 0.009 0.011 0.011 0.222 A005 Position#3 AUX TB Open/Buried 0.00E+00 5.07E+03 9.15E+05 8.30E+02 5.51E+01 4.15E+05 0.00E+00 0.00E+00 0.010 0.012 0.012 0.250 A020 Position#1 AUX TB Open/Buried 0.00E+00 5.13E+03 9.26E+05 8.40E+02 5.58E+01 4.20E+05 0.00E+00 0.00E+00 0.010 0.012 0.012 0.253 A020 Position#2 AUX TB Open/Buried 0.00E+00 5.98E+03 1.08E+06 9.80E+02 6.51E+01 4.90E+05 0.00E+00 0.00E+00 0.012 0.015 0.014 0.296 A020 Position#3 AUX TB Open/Buried 0.00E+00 5.95E+03 1.07E+06 9.74E+02 6.47E+01 4.87E+05 0.00E+00 0.00E+00 0.012 0.014 0.014 0.294 A021 Position#1 AUX TB Open/Buried 0.00E+00 6.67E+03 1.20E+06 1.09E+03 7.25E+01 5.46E+05 0.00E+00 0.00E+00 0.013 0.016 0.016 0.330 A021 Position#2 AUX TB Open/Buried 0.00E+00 5.59E+03 1.01E+06 9.16E+02 6.08E+01 4.58E+05 0.00E+00 0.00E+00 0.011 0.014 0.013 0.276 A021 Position#3 AUX TB Open/Buried 0.00E+00 5.63E+03 1.02E+06 9.22E+02 6.12E+01 4.61E+05 0.00E+00 0.00E+00 0.011 0.014 0.013 0.278 A022 Position#1 AUX TB Open/Buried 0.00E+00 4.44E+03 8.01E+05 7.27E+02 4.83E+01 3.64E+05 0.00E+00 0.00E+00 0.009 0.011 0.011 0.219 A022 Position#2 AUX TB Open/Buried 0.00E+00 4.46E+03 8.06E+05 7.31E+02 4.85E+01 3.66E+05 0.00E+00 0.00E+00 0.009 0.011 0.011 0.220 A022 Position#3 AUX TB Open/Buried 0.00E+00 6.03E+03 1.09E+06 9.88E+02 6.56E+01 4.94E+05 0.00E+00 0.00E+00 0.012 0.015 0.014 0.298 A023 Position#1 AUX TB Grouted 0.00E+00 6.23E+04 1.12E+07 1.02E+04 6.77E+02 5.10E+06 0.00E+00 0.00E+00 0.121 0.152 0.149 3.076 A023 Position#2 AUX TB Grouted 0.00E+00 8.47E+04 1.53E+07 1.39E+04 9.20E+02 6.93E+06 0.00E+00 0.00E+00 0.165 0.206 0.203 4.181 A023 Position#3 AUX TB Grouted 0.00E+00 6.52E+04 1.18E+07 1.07E+04 7.09E+02 5.34E+06 0.00E+00 0.00E+00 0.127 0.159 0.156 3.219 A017 Position#1 AUX TB Open/Buried 0.00E+00 9.91E+03 1.79E+06 1.62E+03 1.08E+02 8.11E+05 0.00E+00 0.00E+00 0.019 0.024 0.024 0.489 A017 Position#2 AUX TB Open/Buried 0.00E+00 1.07E+04 1.93E+06 1.75E+03 1.16E+02 8.74E+05 0.00E+00 0.00E+00 0.021 0.026 0.026 0.527 A017 Position#3 AUX TB Open/Buried 0.00E+00 1.29E+04 2.32E+06 2.11E+03 1.40E+02 1.05E+06 0.00E+00 0.00E+00 0.025 0.031 0.031 0.636 A010 Position#1 AUX TB Open/Buried 0.00E+00 8.41E+03 1.52E+06 1.38E+03 9.14E+01 6.89E+05 0.00E+00 0.00E+00 0.016 0.020 0.020 0.415 A010 Position#2 AUX TB Open/Buried 0.00E+00 8.59E+03 1.55E+06 1.41E+03 9.33E+01 7.03E+05 0.00E+00 0.00E+00 0.017 0.021 0.021 0.424 A010 Position#3 AUX TB Open/Buried 0.00E+00 1.01E+04 1.82E+06 1.65E+03 1.10E+02 8.25E+05 0.00E+00 0.00E+00 0.020 0.025 0.024 0.497 A001 Position #1 AUX TB Open/Buried 0.00E+00 4.20E+02 7.59E+04 6.88E+01 4.57E+00 3.44E+04 0.00E+00 0.00E+00 0.001 0.001 0.001 0.021 A001 Position #2 AUX TB Open/Buried 0.00E+00 4.61E+02 8.33E+04 7.56E+01 5.02E+00 3.78E+04 0.00E+00 0.00E+00 0.001 0.001 0.001 0.023 A001 Position #3 AUX TB Open/Buried 0.00E+00 4.37E+02 7.89E+04 7.16E+01 4.75E+00 3.58E+04 0.00E+00 0.00E+00 0.001 0.001 0.001 0.022 A014 Position #1 AUX TB Open/Buried 0.00E+00 2.71E+02 4.88E+04 4.43E+01 2.94E+00 2.22E+04 0.00E+00 0.00E+00 0.001 0.001 0.001 0.013 A014 Position #2 AUX TB Open/Buried 0.00E+00 3.53E+02 6.36E+04 5.78E+01 3.83E+00 2.89E+04 0.00E+00 0.00E+00 0.001 0.001 0.001 0.017 A014 Position #3 AUX TB Open/Buried 0.00E+00 4.06E+02 7.32E+04 6.65E+01 4.41E+00 3.32E+04 0.00E+00 0.00E+00 0.001 0.001 0.001 0.020 A004 Position #1 AUX TB Open/Buried 0.00E+00 3.79E+02 6.84E+04 6.21E+01 4.12E+00 3.11E+04 0.00E+00 0.00E+00 0.001 0.001 0.001 0.019 A004 Position #2 AUX TB Open/Buried 0.00E+00 3.38E+02 6.10E+04 5.54E+01 3.68E+00 2.77E+04 0.00E+00 0.00E+00 0.001 0.001 0.001 0.017 MEASUREMENT ID BETWEEN END STATE
~
=ZIONSOLUTIONSuc-An Er,e,,gyS~ Company
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
FSS RELEASE RECORD, REV 1 PENETRATIONS SURVEY UNITS 01112, 02112 and 05120
[104]
Turbine Building Penetration Measurements (continued)
H-3 (1)
Co-60 (2)
Ni-63 (1)
Sr-90 (1)
Cs-134 (2)
Cs-137 (2)
Eu-152 (2)
Eu-154 (2)
OpSOFPN OpSOFPN OpSOFB OpSOFB (pCi/m2)
(pCi/m2)
(pCi/m2)
(pCi/m2)
(pCi/m2)
(pCi/m2)
(pCi/m2)
(pCi/m2)
ABPN Limiting DCGL AB DCGL Limiting DCGL A004 Position #3 AUX TB Open/Buried 0.00E+00 4.32E+02 7.80E+04 7.08E+01 4.70E+00 3.54E+04 0.00E+00 0.00E+00 0.001 0.001 0.001 0.021 A024 Position #1 AUX TB Open/Buried 0.00E+00 4.49E+02 8.11E+04 7.36E+01 4.88E+00 3.68E+04 0.00E+00 0.00E+00 0.001 0.001 0.001 0.022 A024 Position #2 AUX TB Open/Buried 0.00E+00 7.61E+02 1.37E+05 1.25E+02 8.27E+00 6.23E+04 0.00E+00 0.00E+00 0.001 0.002 0.002 0.038 A024 Position #3 AUX TB Open/Buried 0.00E+00 1.34E+03 2.42E+05 2.20E+02 1.46E+01 1.10E+05 0.00E+00 0.00E+00 0.003 0.003 0.003 0.066 A025 Position #1 AUX TB Open/Buried 0.00E+00 3.31E+02 5.97E+04 5.42E+01 3.60E+00 2.71E+04 0.00E+00 0.00E+00 0.001 0.001 0.001 0.016 A025 Position #2 AUX TB Open/Buried 0.00E+00 3.14E+02 5.67E+04 5.14E+01 3.41E+00 2.57E+04 0.00E+00 0.00E+00 0.001 0.001 0.001 0.016 A025 Position #3 AUX TB Open/Buried 0.00E+00 3.55E+02 6.41E+04 5.81E+01 3.86E+00 2.91E+04 0.00E+00 0.00E+00 0.001 0.001 0.001 0.018 MEASUREMENT ID BETWEEN END STATE
~
=ZIONSOLUTIONSuc-An Er,e,,gyS~ Company
[105]
ATTACHMENT 3 SIGN TEST
FSS RELEASE RECORD, REV 1 PENETRATIONS SURVEY UNITS 01112, 02112 and 05120
[106]
Sign Test Unit 1 Containment Basement Penetrations Survey Area 01112 Description Unit 1 Containment Survey Unit S1-01112F Description Penetrations Classification 1
Type I Error 0.05
- of Measurements 369 SOF 1-Ws Sign SOF 1-Ws Sign (Ws)
(Ws) 0 0.402 0.598
+1 184 0.145 0.855
+1 1
0.112 0.888
+1 185 0.150 0.850
+1 2
0.067 0.933
+1 186 0.153 0.847
+1 3
0.061 0.939
+1 187 0.154 0.846
+1 4
0.116 0.884
+1 188 0.302 0.698
+1 5
0.061 0.939
+1 189 0.112 0.888
+1 6
0.072 0.928
+1 190 0.102 0.898
+1 7
0.282 0.718
+1 191 0.059 0.941
+1 8
0.325 0.675
+1 192 0.120 0.880
+1 9
0.066 0.934
+1 193 0.306 0.694
+1 10 0.058 0.942
+1 194 0.074 0.926
+1 11 0.060 0.940
+1 195 0.077 0.923
+1 12 0.068 0.932
+1 196 0.087 0.913
+1 13 0.003 0.997
+1 197 0.145 0.855
+1 14 0.004 0.996
+1 198 0.153 0.847
+1 15 0.003 0.997
+1 199 0.199 0.801
+1 16 0.001 0.999
+1 200 0.233 0.767
+1 17 0.005 0.995
+1 201 0.276 0.724
+1 18 0.003 0.997
+1 202 0.063 0.937
+1 19 0.004 0.996
+1 203 0.066 0.934
+1 20 0.002 0.998
+1 204 0.078 0.922
+1 21 0.008 0.992
+1 205 0.083 0.917
+1 22 0.005 0.995
+1 206 0.443 0.557
+1 23 0.401 0.599
+1 207 0.109 0.891
+1 24 0.265 0.735
+1 208 0.066 0.934
+1 25 0.081 0.919
+1 209 0.054 0.946
+1 26 0.056 0.944
+1 210 0.053 0.947
+1 27 0.052 0.948
+1 211 0.210 0.790
+1 28 0.058 0.942
+1 212 0.230 0.770
+1 29 1.034
-0.034
-1 213 0.300 0.700
+1
~
=ZIONSOLlJTJONSLLc-
,..,ErawSCIMionlCompany
FSS RELEASE RECORD, REV 1 PENETRATIONS SURVEY UNITS 01112, 02112 and 05120
[107]
SOF 1-Ws Sign SOF 1-Ws Sign (Ws)
(Ws) 30 1.729
-0.729
-1 214 0.004 0.996
+1 31 0.039 0.961
+1 215 0.127 0.873
+1 32 0.376 0.624
+1 216 0.004 0.996
+1 33 0.090 0.910
+1 217 0.005 0.995
+1 34 0.059 0.941
+1 218 0.011 0.989
+1 35 0.057 0.943
+1 219 0.218 0.782
+1 36 0.073 0.927
+1 220 0.004 0.996
+1 37 0.677 0.323
+1 221 0.235 0.765
+1 38 0.245 0.755
+1 222 0.071 0.929
+1 39 0.179 0.821
+1 223 0.068 0.932
+1 40 0.166 0.834
+1 224 0.070 0.930
+1 41 0.162 0.838
+1 225 0.099 0.901
+1 42 0.156 0.844
+1 226 0.094 0.906
+1 43 0.152 0.848
+1 227 0.298 0.702
+1 44 0.157 0.843
+1 228 0.078 0.922
+1 45 0.154 0.846
+1 229 0.057 0.943
+1 46 0.148 0.852
+1 230 0.061 0.939
+1 47 0.149 0.851
+1 231 0.272 0.728
+1 48 0.153 0.847
+1 232 0.348 0.652
+1 49 0.150 0.850
+1 233 0.552 0.448
+1 50 0.152 0.848
+1 234 0.233 0.767
+1 51 0.154 0.846
+1 235 0.076 0.924
+1 52 0.151 0.849
+1 236 0.060 0.940
+1 53 0.149 0.851
+1 237 0.055 0.945
+1 54 0.147 0.853
+1 238 0.066 0.934
+1 55 0.144 0.856
+1 239 0.306 0.694
+1 56 0.138 0.862
+1 240 0.107 0.893
+1 57 0.134 0.866
+1 241 0.071 0.929
+1 58 0.135 0.865
+1 242 0.061 0.939
+1 59 0.133 0.867
+1 243 0.082 0.918
+1 60 0.126 0.874
+1 244 0.349 0.651
+1 61 0.130 0.870
+1 245 0.003 0.997
+1 62 0.129 0.871
+1 246 0.002 0.998
+1 63 0.126 0.874
+1 247 0.006 0.994
+1 64 0.131 0.869
+1 248 0.003 0.997
+1 65 0.130 0.870
+1 249 0.002 0.998
+1
~
=ZIONSOLlJTJONSLLc-
,..,ErawSCIMionlCompany
FSS RELEASE RECORD, REV 1 PENETRATIONS SURVEY UNITS 01112, 02112 and 05120
[108]
SOF 1-Ws Sign SOF 1-Ws Sign (Ws)
(Ws) 66 0.130 0.870
+1 250 0.003 0.997
+1 67 0.133 0.867
+1 251 0.002 0.998
+1 68 0.135 0.865
+1 252 0.002 0.998
+1 69 0.135 0.865
+1 253 0.354 0.646
+1 70 0.141 0.859
+1 254 0.144 0.856
+1 71 0.142 0.858
+1 255 0.098 0.902
+1 72 0.147 0.853
+1 256 0.083 0.917
+1 73 0.145 0.855
+1 257 0.096 0.904
+1 74 0.146 0.854
+1 258 0.004 0.996
+1 75 0.144 0.856
+1 259 0.067 0.933
+1 76 0.143 0.857
+1 260 0.003 0.997
+1 77 0.146 0.854
+1 261 0.002 0.998
+1 78 0.151 0.849
+1 262 0.005 0.995
+1 79 0.148 0.852
+1 263 0.002 0.998
+1 80 0.154 0.846
+1 264 0.003 0.997
+1 81 0.160 0.840
+1 265 0.002 0.998
+1 82 0.160 0.840
+1 266 8.048
-7.048
-1 83 0.164 0.836
+1 267 9.166
-8.166
-1 84 0.166 0.834
+1 268 10.082
-9.082
-1 85 0.172 0.828
+1 269 9.743
-8.743
-1 86 0.186 0.814
+1 270 8.951
-7.951
-1 87 0.166 0.834
+1 271 7.930
-6.930
-1 88 0.897 0.103
+1 272 7.411
-6.411
-1 89 0.306 0.694
+1 273 6.935
-5.935
-1 90 0.179 0.821
+1 274 6.543
-5.543
-1 91 0.165 0.835
+1 275 6.977
-5.977
-1 92 0.163 0.837
+1 276 7.319
-6.319
-1 93 0.158 0.842
+1 277 7.305
-6.305
-1 94 0.149 0.851
+1 278 7.685
-6.685
-1 95 0.149 0.851
+1 279 6.853
-5.853
-1 96 0.145 0.855
+1 280 5.327
-4.327
-1 97 0.146 0.854
+1 281 4.503
-3.503
-1 98 0.145 0.855
+1 282 4.200
-3.200
-1 99 0.143 0.857
+1 283 4.052
-3.052
-1 100 0.141 0.859
+1 284 4.185
-3.185
-1 101 0.142 0.858
+1 285 3.396
-2.396
-1
~
=ZIONSOLlJTJONSLLc-
,..,ErawSCIMionlCompany
FSS RELEASE RECORD, REV 1 PENETRATIONS SURVEY UNITS 01112, 02112 and 05120
[109]
SOF 1-Ws Sign SOF 1-Ws Sign (Ws)
(Ws) 102 0.145 0.855
+1 286 2.505
-1.505
-1 103 0.140 0.860
+1 287 2.193
-1.193
-1 104 0.143 0.857
+1 288 1.597
-0.597
-1 105 0.140 0.860
+1 289 0.879 0.121
+1 106 0.139 0.861
+1 290 0.687 0.313
+1 107 0.136 0.864
+1 291 0.571 0.429
+1 108 0.127 0.873
+1 292 0.567 0.433
+1 109 0.128 0.872
+1 293 0.442 0.558
+1 110 0.127 0.873
+1 294 0.336 0.664
+1 111 0.121 0.879
+1 295 0.291 0.709
+1 112 0.123 0.877
+1 296 0.274 0.726
+1 113 0.122 0.878
+1 297 0.264 0.736
+1 114 0.126 0.874
+1 298 0.277 0.723
+1 115 0.129 0.871
+1 299 0.303 0.697
+1 116 0.126 0.874
+1 300 0.378 0.622
+1 117 0.129 0.871
+1 301 0.305 0.695
+1 118 0.128 0.872
+1 302 0.299 0.701
+1 119 0.131 0.869
+1 303 0.249 0.751
+1 120 0.132 0.868
+1 304 0.230 0.770
+1 121 0.130 0.870
+1 305 0.231 0.769
+1 122 0.132 0.868
+1 306 0.238 0.762
+1 123 0.133 0.867
+1 307 0.262 0.738
+1 124 0.131 0.869
+1 308 0.258 0.742
+1 125 0.131 0.869
+1 309 0.359 0.641
+1 126 0.128 0.872
+1 310 0.252 0.748
+1 127 0.130 0.870
+1 311 0.224 0.776
+1 128 0.135 0.865
+1 312 0.233 0.767
+1 129 0.133 0.867
+1 313 0.274 0.726
+1 130 0.133 0.867
+1 314 0.258 0.742
+1 131 0.139 0.861
+1 315 0.247 0.753
+1 132 0.138 0.862
+1 316 3.103
-2.103
-1 133 0.148 0.852
+1 317 2.573
-1.573
-1 134 0.158 0.842
+1 318 2.688
-1.688
-1 135 0.178 0.822
+1 319 2.717
-1.717
-1 136 0.159 0.841
+1 320 2.680
-1.680
-1 137 0.142 0.858
+1 321 2.543
-1.543
-1
~
=ZIONSOLlJTJONSLLc-
,..,ErawSCIMionlCompany
FSS RELEASE RECORD, REV 1 PENETRATIONS SURVEY UNITS 01112, 02112 and 05120
[110]
SOF 1-Ws Sign SOF 1-Ws Sign (Ws)
(Ws) 138 0.591 0.409
+1 322 2.256
-1.256
-1 139 0.274 0.726
+1 323 2.180
-1.180
-1 140 0.291 0.709
+1 324 2.190
-1.190
-1 141 0.170 0.830
+1 325 2.232
-1.232
-1 142 0.158 0.842
+1 326 2.311
-1.311
-1 143 0.162 0.838
+1 327 2.352
-1.352
-1 144 0.153 0.847
+1 328 2.381
-1.381
-1 145 0.153 0.847
+1 329 2.480
-1.480
-1 146 0.148 0.852
+1 330 2.384
-1.384
-1 147 0.150 0.850
+1 331 1.907
-0.907
-1 148 0.149 0.851
+1 332 1.673
-0.673
-1 149 0.150 0.850
+1 333 1.551
-0.551
-1 150 0.153 0.847
+1 334 1.343
-0.343
-1 151 0.150 0.850
+1 335 1.111
-0.111
-1 152 0.145 0.855
+1 336 0.928 0.072
+1 153 0.147 0.853
+1 337 0.747 0.253
+1 154 0.146 0.854
+1 338 0.532 0.468
+1 155 0.141 0.859
+1 339 0.390 0.610
+1 156 0.148 0.852
+1 340 0.307 0.693
+1 157 0.147 0.853
+1 341 0.300 0.700
+1 158 0.143 0.857
+1 342 0.258 0.742
+1 159 0.143 0.857
+1 343 0.240 0.760
+1 160 0.139 0.861
+1 344 0.221 0.779
+1 161 0.132 0.868
+1 345 0.212 0.788
+1 162 0.129 0.871
+1 346 0.212 0.788
+1 163 0.132 0.868
+1 347 0.201 0.799
+1 164 0.129 0.871
+1 348 0.200 0.800
+1 165 0.131 0.869
+1 349 0.199 0.801
+1 166 0.132 0.868
+1 350 0.222 0.778
+1 167 0.131 0.869
+1 351 0.200 0.800
+1 168 0.131 0.869
+1 352 0.188 0.812
+1 169 0.136 0.864
+1 353 0.183 0.817
+1 170 0.135 0.865
+1 354 0.183 0.817
+1 171 0.135 0.865
+1 355 0.188 0.812
+1 172 0.133 0.867
+1 356 0.180 0.820
+1 173 0.135 0.865
+1 357 0.182 0.818
+1
~
=ZIONSOLlJTJONSLLc-
,..,ErawSCIMionlCompany
FSS RELEASE RECORD, REV 1 PENETRATIONS SURVEY UNITS 01112, 02112 and 05120
[111]
SOF 1-Ws Sign SOF 1-Ws Sign (Ws)
(Ws) 174 0.137 0.863
+1 358 0.191 0.809
+1 175 0.133 0.867
+1 359 0.192 0.808
+1 176 0.133 0.867
+1 360 0.182 0.818
+1 177 0.133 0.867
+1 361 0.180 0.820
+1 178 0.136 0.864
+1 362 0.174 0.826
+1 179 0.138 0.862
+1 363 0.169 0.831
+1 180 0.139 0.861
+1 364 0.174 0.826
+1 181 0.142 0.858
+1 365 0.171 0.829
+1 182 0.141 0.859
+1 366 0.004 0.996
+1 183 0.145 0.855
+1 367 0.003 0.997
+1 Number of Positive Differences (S+) =
323 Critical Value =
200 Survey Unit Meets the Acceptance Criteria
~
=ZIONSOLlJTJONSLLc-
,..,ErawSCIMionlCompany
FSS RELEASE RECORD, REV 1 PENETRATIONS SURVEY UNITS 01112, 02112 and 05120
[112]
Sign Test Unit 2 Containment Basement Penetrations Survey Area 02112 Description Unit 2 Containment Basement Survey Unit S1-02112F Description Penetrations Classification 1
Type I Error 0.05
- of Measurements 369 SOF 1-Ws Sign SOF 1-Ws Sign (Ws)
(Ws) 0 0.803 0.197
+1 185 0.375 0.625
+1 1
0.111 0.889
+1 186 0.069 0.931
+1 2
0.071 0.929
+1 187 0.058 0.942
+1 3
0.071 0.929
+1 188 0.060 0.940
+1 4
0.106 0.894
+1 189 0.059 0.941
+1 5
0.062 0.938
+1 190 0.672 0.328
+1 6
0.055 0.945
+1 191 0.078 0.922
+1 7
0.048 0.952
+1 192 0.056 0.944
+1 8
0.120 0.880
+1 193 0.053 0.947
+1 9
0.460 0.540
+1 194 0.053 0.947
+1 10 0.069 0.931
+1 195 0.062 0.938
+1 11 0.059 0.941
+1 196 0.065 0.935
+1 12 0.064 0.936
+1 197 0.070 0.930
+1 13 0.055 0.945
+1 198 0.080 0.920
+1 14 0.008 0.992
+1 199 0.154 0.846
+1 15 0.007 0.993
+1 200 0.140 0.860
+1 16 0.002 0.998
+1 201 0.053 0.947
+1 17 0.002 0.998
+1 202 0.049 0.951
+1 18 0.005 0.995
+1 203 0.051 0.949
+1 19 0.005 0.995
+1 204 0.469 0.531
+1 20 0.005 0.995
+1 205 0.056 0.944
+1 21 0.002 0.998
+1 206 0.045 0.955
+1 22 0.004 0.996
+1 207 0.042 0.958
+1 23 0.013 0.987
+1 208 0.046 0.954
+1 24 0.269 0.731
+1 209 0.069 0.931
+1 25 0.088 0.912
+1 210 0.067 0.933
+1 26 0.083 0.917
+1 211 0.062 0.938
+1 27 0.100 0.900
+1 212 0.064 0.936
+1 28 0.003 0.997
+1 213 0.194 0.806
+1 29 0.003 0.997
+1 214 0.013 0.987
+1
~
=ZIONSOLlJTJONSLLc-
,..,ErawSCIMionlCompany
FSS RELEASE RECORD, REV 1 PENETRATIONS SURVEY UNITS 01112, 02112 and 05120
[113]
SOF 1-Ws Sign SOF 1-Ws Sign (Ws)
(Ws) 30 0.002 0.998
+1 215 0.003 0.997
+1 31 0.363 0.637
+1 216 0.008 0.992
+1 32 0.086 0.914
+1 217 0.003 0.997
+1 33 0.074 0.926
+1 218 0.011 0.989
+1 34 0.085 0.915
+1 219 0.019 0.981
+1 35 0.350 0.650
+1 220 0.003 0.997
+1 36 0.187 0.813
+1 221 0.505 0.495
+1 37 0.150 0.850
+1 222 0.070 0.930
+1 38 0.152 0.848
+1 223 0.048 0.952
+1 39 0.150 0.850
+1 224 0.049 0.951
+1 40 0.151 0.849
+1 225 0.047 0.953
+1 41 0.148 0.852
+1 226 0.574 0.426
+1 42 0.149 0.851
+1 227 0.114 0.886
+1 43 0.152 0.848
+1 228 0.085 0.915
+1 44 0.151 0.849
+1 229 0.078 0.922
+1 45 0.147 0.853
+1 230 0.047 0.953
+1 46 0.147 0.853
+1 231 0.059 0.941
+1 47 0.146 0.854
+1 232 0.067 0.933
+1 48 0.146 0.854
+1 233 0.082 0.918
+1 49 0.145 0.855
+1 234 0.217 0.783
+1 50 0.143 0.857
+1 235 0.383 0.617
+1 51 0.144 0.856
+1 236 0.081 0.919
+1 52 0.143 0.857
+1 237 0.061 0.939
+1 53 0.140 0.860
+1 238 0.070 0.930
+1 54 0.133 0.867
+1 239 0.229 0.771
+1 55 0.130 0.870
+1 240 0.078 0.922
+1 56 0.128 0.872
+1 241 0.067 0.933
+1 57 0.126 0.874
+1 242 0.082 0.918
+1 58 0.122 0.878
+1 243 0.004 0.996
+1 59 0.123 0.877
+1 244 0.003 0.997
+1 60 0.123 0.877
+1 245 0.004 0.996
+1 61 0.128 0.872
+1 246 0.002 0.998
+1 62 0.125 0.875
+1 247 0.001 0.999
+1 63 0.128 0.872
+1 248 0.002 0.998
+1 64 0.126 0.874
+1 249 0.003 0.997
+1 65 0.125 0.875
+1 250 0.002 0.998
+1
~
=ZIONSOLlJTJONSLLc-
,..,ErawSCIMionlCompany
FSS RELEASE RECORD, REV 1 PENETRATIONS SURVEY UNITS 01112, 02112 and 05120
[114]
SOF 1-Ws Sign SOF 1-Ws Sign (Ws)
(Ws) 66 0.125 0.875
+1 251 0.002 0.998
+1 67 0.123 0.877
+1 252 0.783 0.217
+1 68 0.124 0.876
+1 253 0.258 0.742
+1 69 0.124 0.876
+1 254 0.340 0.660
+1 70 0.125 0.875
+1 255 0.306 0.694
+1 71 0.124 0.876
+1 256 0.258 0.742
+1 72 0.128 0.872
+1 257 0.354 0.646
+1 73 0.126 0.874
+1 258 0.008 0.992
+1 74 0.124 0.876
+1 259 0.004 0.996
+1 75 0.124 0.876
+1 260 0.002 0.998
+1 76 0.127 0.873
+1 261 0.002 0.998
+1 77 0.128 0.872
+1 262 0.003 0.997
+1 78 0.127 0.873
+1 263 0.003 0.997
+1 79 0.128 0.872
+1 264 0.002 0.998
+1 80 0.133 0.867
+1 265 0.002 0.998
+1 81 0.132 0.868
+1 266 0.529 0.471
+1 82 0.130 0.870
+1 267 0.685 0.315
+1 83 0.130 0.870
+1 268 0.248 0.752
+1 84 0.137 0.863
+1 269 0.190 0.810
+1 85 0.395 0.605
+1 270 0.197 0.803
+1 86 0.211 0.789
+1 271 0.230 0.770
+1 87 0.151 0.849
+1 272 0.231 0.769
+1 88 0.150 0.850
+1 273 0.237 0.763
+1 89 0.149 0.851
+1 274 0.294 0.706
+1 90 0.145 0.855
+1 275 0.284 0.716
+1 91 0.138 0.862
+1 276 0.205 0.795
+1 92 0.137 0.863
+1 277 0.182 0.818
+1 93 0.135 0.865
+1 278 0.176 0.824
+1 94 0.137 0.863
+1 279 0.170 0.830
+1 95 0.133 0.867
+1 280 0.171 0.829
+1 96 0.136 0.864
+1 281 0.174 0.826
+1 97 0.137 0.863
+1 282 0.203 0.797
+1 98 0.135 0.865
+1 283 0.298 0.702
+1 99 0.135 0.865
+1 284 0.228 0.772
+1 100 0.137 0.863
+1 285 0.187 0.813
+1 101 0.137 0.863
+1 286 0.173 0.827
+1
~
=ZIONSOLlJTJONSLLc-
,..,ErawSCIMionlCompany
FSS RELEASE RECORD, REV 1 PENETRATIONS SURVEY UNITS 01112, 02112 and 05120
[115]
SOF 1-Ws Sign SOF 1-Ws Sign (Ws)
(Ws) 102 0.139 0.861
+1 287 0.154 0.846
+1 103 0.138 0.862
+1 288 0.152 0.848
+1 104 0.131 0.869
+1 289 0.146 0.854
+1 105 0.128 0.872
+1 290 0.142 0.858
+1 106 0.126 0.874
+1 291 0.155 0.845
+1 107 0.121 0.879
+1 292 0.201 0.799
+1 108 0.118 0.882
+1 293 0.175 0.825
+1 109 0.120 0.880
+1 294 0.174 0.826
+1 110 0.121 0.879
+1 295 0.151 0.849
+1 111 0.124 0.876
+1 296 0.143 0.857
+1 112 0.126 0.874
+1 297 0.143 0.857
+1 113 0.123 0.877
+1 298 0.143 0.857
+1 114 0.123 0.877
+1 299 0.144 0.856
+1 115 0.125 0.875
+1 300 0.157 0.843
+1 116 0.125 0.875
+1 301 0.195 0.805
+1 117 0.119 0.881
+1 302 0.164 0.836
+1 118 0.124 0.876
+1 303 0.158 0.842
+1 119 0.124 0.876
+1 304 0.150 0.850
+1 120 0.121 0.879
+1 305 0.151 0.849
+1 121 0.127 0.873
+1 306 0.155 0.845
+1 122 0.123 0.877
+1 307 0.155 0.845
+1 123 0.127 0.873
+1 308 0.156 0.844
+1 124 0.129 0.871
+1 309 0.162 0.838
+1 125 0.127 0.873
+1 310 0.171 0.829
+1 126 0.125 0.875
+1 311 0.249 0.751
+1 127 0.127 0.873
+1 312 0.242 0.758
+1 128 0.126 0.874
+1 313 0.202 0.798
+1 129 0.125 0.875
+1 314 0.192 0.808
+1 130 0.128 0.872
+1 315 0.211 0.789
+1 131 0.129 0.871
+1 316 0.167 0.833
+1 132 0.130 0.870
+1 317 0.444 0.556
+1 133 0.126 0.874
+1 318 0.201 0.799
+1 134 0.132 0.868
+1 319 0.159 0.841
+1 135 0.455 0.545
+1 320 0.164 0.836
+1 136 0.210 0.790
+1 321 0.163 0.837
+1 137 0.156 0.844
+1 322 0.156 0.844
+1
~
=ZIONSOLlJTJONSLLc-
,..,ErawSCIMionlCompany
FSS RELEASE RECORD, REV 1 PENETRATIONS SURVEY UNITS 01112, 02112 and 05120
[116]
SOF 1-Ws Sign SOF 1-Ws Sign (Ws)
(Ws) 138 0.152 0.848
+1 323 0.153 0.847
+1 139 0.152 0.848
+1 324 0.162 0.838
+1 140 0.147 0.853
+1 325 0.173 0.827
+1 141 0.144 0.856
+1 326 0.158 0.842
+1 142 0.141 0.859
+1 327 0.151 0.849
+1 143 0.148 0.852
+1 328 0.155 0.845
+1 144 0.142 0.858
+1 329 0.153 0.847
+1 145 0.141 0.859
+1 330 0.155 0.845
+1 146 0.146 0.854
+1 331 0.156 0.844
+1 147 0.146 0.854
+1 332 0.160 0.840
+1 148 0.143 0.857
+1 333 0.183 0.817
+1 149 0.148 0.852
+1 334 0.194 0.806
+1 150 0.142 0.858
+1 335 0.167 0.833
+1 151 0.145 0.855
+1 336 0.160 0.840
+1 152 0.153 0.847
+1 337 0.170 0.830
+1 153 0.149 0.851
+1 338 0.157 0.843
+1 154 0.138 0.862
+1 339 0.141 0.859
+1 155 0.126 0.874
+1 340 0.140 0.860
+1 156 0.127 0.873
+1 341 0.139 0.861
+1 157 0.125 0.875
+1 342 0.189 0.811
+1 158 0.121 0.879
+1 343 0.238 0.762
+1 159 0.125 0.875
+1 344 0.156 0.844
+1 160 0.121 0.879
+1 345 0.140 0.860
+1 161 0.125 0.875
+1 346 0.137 0.863
+1 162 0.125 0.875
+1 347 0.134 0.866
+1 163 0.126 0.874
+1 348 0.136 0.864
+1 164 0.123 0.877
+1 349 0.141 0.859
+1 165 0.123 0.877
+1 350 0.159 0.841
+1 166 0.123 0.877
+1 351 0.264 0.736
+1 167 0.122 0.878
+1 352 0.305 0.695
+1 168 0.122 0.878
+1 353 0.241 0.759
+1 169 0.122 0.878
+1 354 0.177 0.823
+1 170 0.124 0.876
+1 355 0.156 0.844
+1 171 0.123 0.877
+1 356 0.142 0.858
+1 172 0.122 0.878
+1 357 0.140 0.860
+1 173 0.126 0.874
+1 358 0.141 0.859
+1
~
=ZIONSOLlJTJONSLLc-
,..,ErawSCIMionlCompany
FSS RELEASE RECORD, REV 1 PENETRATIONS SURVEY UNITS 01112, 02112 and 05120
[117]
SOF 1-Ws Sign SOF 1-Ws Sign (Ws)
(Ws) 174 0.122 0.878
+1 359 0.159 0.841
+1 175 0.124 0.876
+1 360 0.271 0.729
+1 176 0.123 0.877
+1 361 0.227 0.773
+1 177 0.124 0.876
+1 362 0.167 0.833
+1 178 0.123 0.877
+1 363 0.164 0.836
+1 179 0.128 0.872
+1 364 0.179 0.821
+1 180 0.123 0.877
+1 365 0.227 0.773
+1 181 0.126 0.874
+1 366 0.216 0.784
+1 182 0.126 0.874
+1 367 0.004 0.996
+1 183 0.122 0.878
+1 368 0.002 0.998
+1 184 0.124 0.876
+1 Number of Positive Differences (S+) =
369 Critical Value =
200 Survey Unit Meets the Acceptance Criteria
~
=ZIONSOLlJTJONSLLc-
,..,ErawSCIMionlCompany
FSS RELEASE RECORD, REV 1 PENETRATIONS SURVEY UNITS 01112, 02112 and 05120
[118]
Sign Test Auxiliary Building Basement Penetrations Survey Area 05120 Description Auxiliary Building Basement Survey Unit S1-05120AF Description Penetrations Classification 1
Type I Error 0.05
- of Measurements 66 SOF 1-Ws Sign SOF 1-Ws Sign (Ws)
(Ws) 1 0.001 0.999
+1 378 1.343
-0.343
-1 2
0.001 0.999
+1 379 1.111
-0.111
-1 3
0.001 0.999
+1 380 0.928 0.072
+1 4
0.013 0.987
+1 381 0.747 0.253
+1 5
0.012 0.988
+1 382 0.532 0.468
+1 6
0.015 0.985
+1 383 0.390 0.610
+1 7
0.017 0.983
+1 384 0.307 0.693
+1 8
0.018 0.982
+1 385 0.300 0.700
+1 9
0.042 0.958
+1 386 0.258 0.742
+1 10 0.001 0.999
+1 387 0.240 0.760
+1 11 0.001 0.999
+1 388 0.221 0.779
+1 12 0.001 0.999
+1 389 0.212 0.788
+1 13 0.011 0.989
+1 390 0.212 0.788
+1 14 0.011 0.989
+1 391 0.201 0.799
+1 15 0.012 0.988
+1 392 0.200 0.800
+1 16 0.012 0.988
+1 393 0.199 0.801
+1 17 0.012 0.988
+1 394 0.222 0.778
+1 18 0.013 0.987
+1 395 0.200 0.800
+1 19 0.015 0.985
+1 396 0.188 0.812
+1 20 0.014 0.986
+1 397 0.183 0.817
+1 21 0.014 0.986
+1 398 0.183 0.817
+1 22 0.013 0.987
+1 399 0.188 0.812
+1 23 0.013 0.987
+1 400 0.180 0.820
+1 24 0.013 0.987
+1 401 0.182 0.818
+1 25 0.020 0.980
+1 402 0.191 0.809
+1 26 0.021 0.979
+1 403 0.192 0.808
+1 27 0.025 0.975
+1 404 0.182 0.818
+1 28 0.303 0.697
+1 405 0.180 0.820
+1 29 0.349 0.651
+1 406 0.174 0.826
+1 30 0.294 0.706
+1 407 0.169 0.831
+1 31 0.013 0.987
+1 408 0.174 0.826
+1
~
=ZIONSOLlJTJONSLLc-
,..,ErawSCIMionlCompany
FSS RELEASE RECORD, REV 1 PENETRATIONS SURVEY UNITS 01112, 02112 and 05120
[119]
SOF 1-Ws Sign SOF 1-Ws Sign (Ws)
(Ws) 31 0.013 0.987
+1 409 0.171 0.829
+1 32 0.017 0.983
+1 410 0.803 0.197
+1 33 0.019 0.981
+1 411 0.111 0.889
+1 34 0.020 0.980
+1 412 0.071 0.929
+1 35 0.021 0.979
+1 413 0.071 0.929
+1 36 0.001 0.999
+1 414 0.106 0.894
+1 37 0.001 0.999
+1 415 0.062 0.938
+1 38 0.001 0.999
+1 416 0.055 0.945
+1 39 0.016 0.984
+1 417 0.048 0.952
+1 40 0.016 0.984
+1 418 0.120 0.880
+1 41 0.018 0.982
+1 419 0.460 0.540
+1 42 0.024 0.976
+1 420 0.069 0.931
+1 43 0.026 0.974
+1 421 0.059 0.941
+1 44 0.031 0.969
+1 422 0.064 0.936
+1 45 0.012 0.988
+1 423 0.055 0.945
+1 46 0.012 0.988
+1 424 0.004 0.996
+1 47 0.013 0.987
+1 425 0.013 0.987
+1 48 0.012 0.988
+1 426 0.269 0.731
+1 49 0.015 0.985
+1 427 0.088 0.912
+1 50 0.014 0.986
+1 428 0.083 0.917
+1 51 0.016 0.984
+1 429 0.100 0.900
+1 52 0.014 0.986
+1 430 0.003 0.997
+1 53 0.014 0.986
+1 431 0.003 0.997
+1 54 0.011 0.989
+1 432 0.002 0.998
+1 55 0.011 0.989
+1 433 0.363 0.637
+1 56 0.015 0.985
+1 434 0.086 0.914
+1 57 0.152 0.848
+1 435 0.074 0.926
+1 58 0.206 0.794
+1 436 0.085 0.915
+1 59 0.159 0.841
+1 437 0.350 0.650
+1 60 0.001 0.999
+1 438 0.187 0.813
+1 61 0.002 0.998
+1 439 0.150 0.850
+1 62 0.003 0.997
+1 440 0.152 0.848
+1 63 0.001 0.999
+1 441 0.150 0.850
+1 64 0.001 0.999
+1 442 0.151 0.849
+1 65 0.001 0.999
+1 443 0.148 0.852
+1 66 0.402 0.598
+1 444 0.149 0.851
+1
~
=ZIONSOLlJTJONSLLc-
,..,ErawSCIMionlCompany
FSS RELEASE RECORD, REV 1 PENETRATIONS SURVEY UNITS 01112, 02112 and 05120
[120]
SOF 1-Ws Sign SOF 1-Ws Sign (Ws)
(Ws) 67 0.112 0.888
+1 445 0.152 0.848
+1 68 0.067 0.933
+1 446 0.151 0.849
+1 69 0.061 0.939
+1 447 0.147 0.853
+1 70 0.116 0.884
+1 448 0.147 0.853
+1 71 0.061 0.939
+1 449 0.146 0.854
+1 72 0.072 0.928
+1 450 0.146 0.854
+1 73 0.282 0.718
+1 451 0.145 0.855
+1 74 0.325 0.675
+1 452 0.143 0.857
+1 75 0.066 0.934
+1 453 0.144 0.856
+1 76 0.058 0.942
+1 454 0.143 0.857
+1 77 0.060 0.940
+1 455 0.140 0.860
+1 78 0.068 0.932
+1 456 0.133 0.867
+1 79 0.008 0.992
+1 457 0.130 0.870
+1 80 0.005 0.995
+1 458 0.128 0.872
+1 81 0.401 0.599
+1 459 0.126 0.874
+1 82 0.265 0.735
+1 460 0.122 0.878
+1 83 0.081 0.919
+1 461 0.123 0.877
+1 84 0.056 0.944
+1 462 0.123 0.877
+1 85 0.052 0.948
+1 463 0.128 0.872
+1 86 0.058 0.942
+1 464 0.125 0.875
+1 87 1.034
-0.034
-1 465 0.128 0.872
+1 88 1.729
-0.729
-1 466 0.126 0.874
+1 89 0.039 0.961
+1 467 0.125 0.875
+1 90 0.376 0.624
+1 468 0.125 0.875
+1 91 0.090 0.910
+1 469 0.123 0.877
+1 92 0.059 0.941
+1 470 0.124 0.876
+1 93 0.057 0.943
+1 471 0.124 0.876
+1 94 0.073 0.927
+1 472 0.125 0.875
+1 95 0.677 0.323
+1 473 0.124 0.876
+1 96 0.245 0.755
+1 474 0.128 0.872
+1 97 0.179 0.821
+1 475 0.126 0.874
+1 98 0.166 0.834
+1 476 0.124 0.876
+1 99 0.162 0.838
+1 477 0.124 0.876
+1 100 0.156 0.844
+1 478 0.127 0.873
+1 101 0.152 0.848
+1 479 0.128 0.872
+1 102 0.157 0.843
+1 480 0.127 0.873
+1
~
=ZIONSOLlJTJONSLLc-
,..,ErawSCIMionlCompany
FSS RELEASE RECORD, REV 1 PENETRATIONS SURVEY UNITS 01112, 02112 and 05120
[121]
SOF 1-Ws Sign SOF 1-Ws Sign (Ws)
(Ws) 103 0.154 0.846
+1 481 0.128 0.872
+1 104 0.148 0.852
+1 482 0.133 0.867
+1 105 0.149 0.851
+1 483 0.132 0.868
+1 106 0.153 0.847
+1 484 0.130 0.870
+1 107 0.150 0.850
+1 485 0.130 0.870
+1 108 0.152 0.848
+1 486 0.137 0.863
+1 109 0.154 0.846
+1 487 0.395 0.605
+1 110 0.151 0.849
+1 488 0.211 0.789
+1 111 0.149 0.851
+1 489 0.151 0.849
+1 112 0.147 0.853
+1 490 0.150 0.850
+1 113 0.144 0.856
+1 491 0.149 0.851
+1 114 0.138 0.862
+1 492 0.145 0.855
+1 115 0.134 0.866
+1 493 0.138 0.862
+1 116 0.135 0.865
+1 494 0.137 0.863
+1 117 0.133 0.867
+1 495 0.135 0.865
+1 118 0.126 0.874
+1 496 0.137 0.863
+1 119 0.130 0.870
+1 497 0.133 0.867
+1 120 0.129 0.871
+1 498 0.136 0.864
+1 121 0.126 0.874
+1 499 0.137 0.863
+1 122 0.131 0.869
+1 500 0.135 0.865
+1 123 0.130 0.870
+1 501 0.135 0.865
+1 124 0.130 0.870
+1 502 0.137 0.863
+1 125 0.133 0.867
+1 503 0.137 0.863
+1 126 0.135 0.865
+1 504 0.139 0.861
+1 127 0.135 0.865
+1 505 0.138 0.862
+1 128 0.141 0.859
+1 506 0.131 0.869
+1 129 0.142 0.858
+1 507 0.128 0.872
+1 130 0.147 0.853
+1 508 0.126 0.874
+1 131 0.145 0.855
+1 509 0.121 0.879
+1 132 0.146 0.854
+1 510 0.118 0.882
+1 133 0.144 0.856
+1 511 0.120 0.880
+1 134 0.143 0.857
+1 512 0.121 0.879
+1 135 0.146 0.854
+1 513 0.124 0.876
+1 136 0.151 0.849
+1 514 0.126 0.874
+1 137 0.148 0.852
+1 515 0.123 0.877
+1 138 0.154 0.846
+1 516 0.123 0.877
+1
~
=ZIONSOLlJTJONSLLc-
,..,ErawSCIMionlCompany
FSS RELEASE RECORD, REV 1 PENETRATIONS SURVEY UNITS 01112, 02112 and 05120
[122]
SOF 1-Ws Sign SOF 1-Ws Sign (Ws)
(Ws) 139 0.160 0.840
+1 517 0.125 0.875
+1 140 0.160 0.840
+1 518 0.125 0.875
+1 141 0.164 0.836
+1 519 0.119 0.881
+1 142 0.166 0.834
+1 520 0.124 0.876
+1 143 0.172 0.828
+1 521 0.124 0.876
+1 144 0.186 0.814
+1 522 0.121 0.879
+1 145 0.166 0.834
+1 523 0.127 0.873
+1 146 0.897 0.103
+1 524 0.123 0.877
+1 147 0.306 0.694
+1 525 0.127 0.873
+1 148 0.179 0.821
+1 526 0.129 0.871
+1 149 0.165 0.835
+1 527 0.127 0.873
+1 150 0.163 0.837
+1 528 0.125 0.875
+1 151 0.158 0.842
+1 529 0.127 0.873
+1 152 0.149 0.851
+1 530 0.126 0.874
+1 153 0.149 0.851
+1 531 0.125 0.875
+1 154 0.145 0.855
+1 532 0.128 0.872
+1 155 0.146 0.854
+1 533 0.129 0.871
+1 156 0.145 0.855
+1 534 0.130 0.870
+1 157 0.143 0.857
+1 535 0.126 0.874
+1 158 0.141 0.859
+1 536 0.132 0.868
+1 159 0.142 0.858
+1 537 0.455 0.545
+1 160 0.145 0.855
+1 538 0.210 0.790
+1 161 0.140 0.860
+1 539 0.156 0.844
+1 162 0.143 0.857
+1 540 0.152 0.848
+1 163 0.140 0.860
+1 541 0.152 0.848
+1 164 0.139 0.861
+1 542 0.147 0.853
+1 165 0.136 0.864
+1 543 0.144 0.856
+1 166 0.127 0.873
+1 544 0.141 0.859
+1 167 0.128 0.872
+1 545 0.148 0.852
+1 168 0.127 0.873
+1 546 0.142 0.858
+1 169 0.121 0.879
+1 547 0.141 0.859
+1 170 0.123 0.877
+1 548 0.146 0.854
+1 171 0.122 0.878
+1 549 0.146 0.854
+1 172 0.126 0.874
+1 550 0.143 0.857
+1 173 0.129 0.871
+1 551 0.148 0.852
+1 174 0.126 0.874
+1 552 0.142 0.858
+1
~
=ZIONSOLlJTJONSLLc-
,..,ErawSCIMionlCompany
FSS RELEASE RECORD, REV 1 PENETRATIONS SURVEY UNITS 01112, 02112 and 05120
[123]
SOF 1-Ws Sign SOF 1-Ws Sign (Ws)
(Ws) 175 0.129 0.871
+1 553 0.145 0.855
+1 176 0.128 0.872
+1 554 0.153 0.847
+1 177 0.131 0.869
+1 555 0.149 0.851
+1 178 0.132 0.868
+1 556 0.138 0.862
+1 179 0.130 0.870
+1 557 0.126 0.874
+1 180 0.132 0.868
+1 558 0.127 0.873
+1 181 0.133 0.867
+1 559 0.125 0.875
+1 182 0.131 0.869
+1 560 0.121 0.879
+1 183 0.131 0.869
+1 561 0.125 0.875
+1 184 0.128 0.872
+1 562 0.121 0.879
+1 185 0.130 0.870
+1 563 0.125 0.875
+1 186 0.135 0.865
+1 564 0.125 0.875
+1 187 0.133 0.867
+1 565 0.126 0.874
+1 188 0.133 0.867
+1 566 0.123 0.877
+1 189 0.139 0.861
+1 567 0.123 0.877
+1 190 0.138 0.862
+1 568 0.123 0.877
+1 191 0.148 0.852
+1 569 0.122 0.878
+1 192 0.158 0.842
+1 570 0.122 0.878
+1 193 0.178 0.822
+1 571 0.122 0.878
+1 194 0.159 0.841
+1 572 0.124 0.876
+1 195 0.142 0.858
+1 573 0.123 0.877
+1 196 0.591 0.409
+1 574 0.122 0.878
+1 197 0.274 0.726
+1 575 0.126 0.874
+1 198 0.291 0.709
+1 576 0.122 0.878
+1 199 0.170 0.830
+1 577 0.124 0.876
+1 200 0.158 0.842
+1 578 0.123 0.877
+1 201 0.162 0.838
+1 579 0.124 0.876
+1 202 0.153 0.847
+1 580 0.123 0.877
+1 203 0.153 0.847
+1 581 0.128 0.872
+1 204 0.148 0.852
+1 582 0.123 0.877
+1 205 0.150 0.850
+1 583 0.126 0.874
+1 206 0.149 0.851
+1 584 0.126 0.874
+1 207 0.150 0.850
+1 585 0.122 0.878
+1 208 0.153 0.847
+1 586 0.124 0.876
+1 209 0.150 0.850
+1 587 0.375 0.625
+1 210 0.145 0.855
+1 588 0.069 0.931
+1
~
=ZIONSOLlJTJONSLLc-
,..,ErawSCIMionlCompany
FSS RELEASE RECORD, REV 1 PENETRATIONS SURVEY UNITS 01112, 02112 and 05120
[124]
SOF 1-Ws Sign SOF 1-Ws Sign (Ws)
(Ws) 211 0.147 0.853
+1 589 0.058 0.942
+1 212 0.146 0.854
+1 590 0.060 0.940
+1 213 0.141 0.859
+1 591 0.059 0.941
+1 214 0.148 0.852
+1 592 0.672 0.328
+1 215 0.147 0.853
+1 593 0.078 0.922
+1 216 0.143 0.857
+1 594 0.056 0.944
+1 217 0.143 0.857
+1 595 0.053 0.947
+1 218 0.139 0.861
+1 596 0.053 0.947
+1 219 0.132 0.868
+1 597 0.062 0.938
+1 220 0.129 0.871
+1 598 0.065 0.935
+1 221 0.132 0.868
+1 599 0.070 0.930
+1 222 0.129 0.871
+1 600 0.080 0.920
+1 223 0.131 0.869
+1 601 0.154 0.846
+1 224 0.132 0.868
+1 602 0.140 0.860
+1 225 0.131 0.869
+1 603 0.053 0.947
+1 226 0.131 0.869
+1 604 0.049 0.951
+1 227 0.136 0.864
+1 605 0.051 0.949
+1 228 0.135 0.865
+1 606 0.469 0.531
+1 229 0.135 0.865
+1 607 0.056 0.944
+1 230 0.133 0.867
+1 608 0.045 0.955
+1 231 0.135 0.865
+1 609 0.042 0.958
+1 232 0.137 0.863
+1 610 0.046 0.954
+1 233 0.133 0.867
+1 611 0.069 0.931
+1 234 0.133 0.867
+1 612 0.067 0.933
+1 235 0.133 0.867
+1 613 0.062 0.938
+1 236 0.136 0.864
+1 614 0.064 0.936
+1 237 0.138 0.862
+1 615 0.194 0.806
+1 238 0.139 0.861
+1 616 0.013 0.987
+1 239 0.142 0.858
+1 617 0.003 0.997
+1 240 0.141 0.859
+1 618 0.008 0.992
+1 241 0.145 0.855
+1 619 0.003 0.997
+1 242 0.145 0.855
+1 620 0.011 0.989
+1 243 0.150 0.850
+1 621 0.019 0.981
+1 244 0.153 0.847
+1 622 0.003 0.997
+1 245 0.154 0.846
+1 623 0.505 0.495
+1 246 0.302 0.698
+1 624 0.070 0.930
+1
~
=ZIONSOLlJTJONSLLc-
,..,ErawSCIMionlCompany
FSS RELEASE RECORD, REV 1 PENETRATIONS SURVEY UNITS 01112, 02112 and 05120
[125]
SOF 1-Ws Sign SOF 1-Ws Sign (Ws)
(Ws) 247 0.112 0.888
+1 625 0.048 0.952
+1 248 0.102 0.898
+1 626 0.049 0.951
+1 249 0.059 0.941
+1 627 0.047 0.953
+1 250 0.120 0.880
+1 628 0.574 0.426
+1 251 0.306 0.694
+1 629 0.114 0.886
+1 252 0.074 0.926
+1 630 0.085 0.915
+1 253 0.077 0.923
+1 631 0.078 0.922
+1 254 0.087 0.913
+1 632 0.047 0.953
+1 255 0.145 0.855
+1 633 0.059 0.941
+1 256 0.153 0.847
+1 634 0.067 0.933
+1 257 0.199 0.801
+1 635 0.082 0.918
+1 258 0.233 0.767
+1 636 0.217 0.783
+1 259 0.276 0.724
+1 637 0.383 0.617
+1 260 0.063 0.937
+1 638 0.081 0.919
+1 261 0.066 0.934
+1 639 0.061 0.939
+1 262 0.078 0.922
+1 640 0.070 0.930
+1 263 0.083 0.917
+1 641 0.229 0.771
+1 264 0.443 0.557
+1 642 0.078 0.922
+1 265 0.109 0.891
+1 643 0.067 0.933
+1 266 0.066 0.934
+1 644 0.082 0.918
+1 267 0.054 0.946
+1 645 0.004 0.996
+1 268 0.053 0.947
+1 646 0.783 0.217
+1 269 0.210 0.790
+1 647 0.258 0.742
+1 270 0.230 0.770
+1 648 0.340 0.660
+1 271 0.300 0.700
+1 649 0.306 0.694
+1 272 0.004 0.996
+1 650 0.258 0.742
+1 273 0.127 0.873
+1 651 0.354 0.646
+1 274 0.004 0.996
+1 652 0.008 0.992
+1 275 0.005 0.995
+1 653 0.004 0.996
+1 276 0.011 0.989
+1 654 0.529 0.471
+1 277 0.218 0.782
+1 655 0.685 0.315
+1 278 0.004 0.996
+1 656 0.248 0.752
+1 279 0.235 0.765
+1 657 0.190 0.810
+1 280 0.071 0.929
+1 658 0.197 0.803
+1 281 0.068 0.932
+1 659 0.230 0.770
+1 282 0.070 0.930
+1 660 0.231 0.769
+1
~
=ZIONSOLlJTJONSLLc-
,..,ErawSCIMionlCompany
FSS RELEASE RECORD, REV 1 PENETRATIONS SURVEY UNITS 01112, 02112 and 05120
[126]
SOF 1-Ws Sign SOF 1-Ws Sign (Ws)
(Ws) 283 0.099 0.901
+1 661 0.237 0.763
+1 284 0.094 0.906
+1 662 0.294 0.706
+1 285 0.298 0.702
+1 663 0.284 0.716
+1 286 0.078 0.922
+1 664 0.205 0.795
+1 287 0.057 0.943
+1 665 0.182 0.818
+1 288 0.061 0.939
+1 666 0.176 0.824
+1 289 0.272 0.728
+1 667 0.170 0.830
+1 290 0.348 0.652
+1 668 0.171 0.829
+1 291 0.552 0.448
+1 669 0.174 0.826
+1 292 0.233 0.767
+1 670 0.203 0.797
+1 293 0.076 0.924
+1 671 0.298 0.702
+1 294 0.060 0.940
+1 672 0.228 0.772
+1 295 0.055 0.945
+1 673 0.187 0.813
+1 296 0.066 0.934
+1 674 0.173 0.827
+1 297 0.306 0.694
+1 675 0.154 0.846
+1 298 0.107 0.893
+1 676 0.152 0.848
+1 299 0.071 0.929
+1 677 0.146 0.854
+1 300 0.061 0.939
+1 678 0.142 0.858
+1 301 0.082 0.918
+1 679 0.155 0.845
+1 302 0.349 0.651
+1 680 0.201 0.799
+1 303 0.354 0.646
+1 681 0.175 0.825
+1 304 0.144 0.856
+1 682 0.174 0.826
+1 305 0.098 0.902
+1 683 0.151 0.849
+1 306 0.083 0.917
+1 684 0.143 0.857
+1 307 0.096 0.904
+1 685 0.143 0.857
+1 308 0.004 0.996
+1 686 0.143 0.857
+1 309 0.067 0.933
+1 687 0.144 0.856
+1 310 8.048
-7.048
-1 688 0.157 0.843
+1 311 9.166
-8.166
-1 689 0.195 0.805
+1 312 10.082
-9.082
-1 690 0.164 0.836
+1 313 9.743
-8.743
-1 691 0.158 0.842
+1 314 8.951
-7.951
-1 692 0.150 0.850
+1 315 7.930
-6.930
-1 693 0.151 0.849
+1 316 7.411
-6.411
-1 694 0.155 0.845
+1 317 6.935
-5.935
-1 695 0.155 0.845
+1 318 6.543
-5.543
-1 696 0.156 0.844
+1
~
=ZIONSOLlJTJONSLLc-
,..,ErawSCIMionlCompany
FSS RELEASE RECORD, REV 1 PENETRATIONS SURVEY UNITS 01112, 02112 and 05120
[127]
SOF 1-Ws Sign SOF 1-Ws Sign (Ws)
(Ws) 319 6.977
-5.977
-1 697 0.162 0.838
+1 320 7.319
-6.319
-1 698 0.171 0.829
+1 321 7.305
-6.305
-1 699 0.249 0.751
+1 322 7.685
-6.685
-1 700 0.242 0.758
+1 323 6.853
-5.853
-1 701 0.202 0.798
+1 324 5.327
-4.327
-1 702 0.192 0.808
+1 325 4.503
-3.503
-1 703 0.211 0.789
+1 326 4.200
-3.200
-1 704 0.167 0.833
+1 327 4.052
-3.052
-1 705 0.444 0.556
+1 328 4.185
-3.185
-1 706 0.201 0.799
+1 329 3.396
-2.396
-1 707 0.159 0.841
+1 330 2.505
-1.505
-1 708 0.164 0.836
+1 331 2.193
-1.193
-1 709 0.163 0.837
+1 332 1.597
-0.597
-1 710 0.156 0.844
+1 333 0.879 0.121
+1 711 0.153 0.847
+1 334 0.687 0.313
+1 712 0.162 0.838
+1 335 0.571 0.429
+1 713 0.173 0.827
+1 336 0.567 0.433
+1 714 0.158 0.842
+1 337 0.442 0.558
+1 715 0.151 0.849
+1 338 0.336 0.664
+1 716 0.155 0.845
+1 339 0.291 0.709
+1 717 0.153 0.847
+1 340 0.274 0.726
+1 718 0.155 0.845
+1 341 0.264 0.736
+1 719 0.156 0.844
+1 342 0.277 0.723
+1 720 0.160 0.840
+1 343 0.303 0.697
+1 721 0.183 0.817
+1 344 0.378 0.622
+1 722 0.194 0.806
+1 345 0.305 0.695
+1 723 0.167 0.833
+1 346 0.299 0.701
+1 724 0.160 0.840
+1 347 0.249 0.751
+1 725 0.170 0.830
+1 348 0.230 0.770
+1 726 0.157 0.843
+1 349 0.231 0.769
+1 727 0.141 0.859
+1 350 0.238 0.762
+1 728 0.140 0.860
+1 351 0.262 0.738
+1 729 0.139 0.861
+1 352 0.258 0.742
+1 730 0.189 0.811
+1 353 0.359 0.641
+1 731 0.238 0.762
+1 354 0.252 0.748
+1 732 0.156 0.844
+1
~
=ZIONSOLlJTJONSLLc-
,..,ErawSCIMionlCompany
FSS RELEASE RECORD, REV 1 PENETRATIONS SURVEY UNITS 01112, 02112 and 05120
[128]
SOF 1-Ws Sign SOF 1-Ws Sign (Ws)
(Ws) 355 0.224 0.776
+1 733 0.140 0.860
+1 356 0.233 0.767
+1 734 0.137 0.863
+1 357 0.274 0.726
+1 735 0.134 0.866
+1 358 0.258 0.742
+1 736 0.136 0.864
+1 359 0.247 0.753
+1 737 0.141 0.859
+1 360 3.103
-2.103
-1 738 0.159 0.841
+1 361 2.573
-1.573
-1 739 0.264 0.736
+1 362 2.688
-1.688
-1 740 0.305 0.695
+1 363 2.717
-1.717
-1 741 0.241 0.759
+1 364 2.680
-1.680
-1 742 0.177 0.823
+1 365 2.543
-1.543
-1 743 0.156 0.844
+1 366 2.256
-1.256
-1 744 0.142 0.858
+1 367 2.180
-1.180
-1 745 0.140 0.860
+1 368 2.190
-1.190
-1 746 0.141 0.859
+1 369 2.232
-1.232
-1 747 0.159 0.841
+1 370 2.311
-1.311
-1 748 0.271 0.729
+1 371 2.352
-1.352
-1 749 0.227 0.773
+1 372 2.381
-1.381
-1 750 0.167 0.833
+1 373 2.480
-1.480
-1 751 0.164 0.836
+1 374 2.384
-1.384
-1 752 0.179 0.821
+1 375 1.907
-0.907
-1 753 0.227 0.773
+1 376 1.673
-0.673
-1 754 0.216 0.784
+1 377 1.551
-0.551
-1 Number of Positive Differences (S+) =
710 Critical Value =
400 Survey Unit Meets the Acceptance Criteria
~
=ZIONSOLlJTJONSLLc-
,..,ErawSCIMionlCompany
FSS RELEASE RECORD, REV 1 PENETRATIONS SURVEY UNITS 01112, 02112 and 05120
[129]
Sign Test Turbine Building Basement Penetrations Survey Area 06100 Description Turbine Building Basement Survey Unit S1-006106AF Description Penetrations Classification 1
Type I Error 0.05
- of Measurements 114 SOF 1-Ws Sign SOF 1-Ws Sign (Ws)
(Ws) 1 0.001 0.999
+1 57 0.152 0.848
+1 2
0.001 0.999
+1 58 0.206 0.794
+1 3
0.001 0.999
+1 59 0.159 0.841
+1 4
0.013 0.987
+1 60 0.001 0.999
+1 5
0.012 0.988
+1 61 0.002 0.998
+1 6
0.015 0.985
+1 62 0.003 0.997
+1 7
0.017 0.983
+1 63 0.001 0.999
+1 8
0.018 0.982
+1 64 0.001 0.999
+1 9
0.042 0.958
+1 65 0.001 0.999
+1 10 0.001 0.999
+1 66 0.003 0.997
+1 11 0.001 0.999
+1 67 0.004 0.996
+1 12 0.001 0.999
+1 68 0.003 0.997
+1 13 0.011 0.989
+1 69 0.001 0.999
+1 14 0.011 0.989
+1 70 0.005 0.995
+1 15 0.012 0.988
+1 71 0.003 0.997
+1 16 0.012 0.988
+1 72 0.004 0.996
+1 17 0.012 0.988
+1 73 0.002 0.998
+1 18 0.013 0.987
+1 74 0.003 0.997
+1 19 0.015 0.985
+1 75 0.002 0.998
+1 20 0.014 0.986
+1 76 0.006 0.994
+1 21 0.014 0.986
+1 77 0.003 0.997
+1 22 0.013 0.987
+1 78 0.002 0.998
+1 23 0.013 0.987
+1 79 0.003 0.997
+1 24 0.013 0.987
+1 80 0.002 0.998
+1 25 0.020 0.980
+1 81 0.002 0.998
+1 26 0.021 0.979
+1 82 0.003 0.997
+1 27 0.025 0.975
+1 83 0.002 0.998
+1 28 0.303 0.697
+1 84 0.005 0.995
+1 29 0.349 0.651
+1 85 0.002 0.998
+1 30 0.294 0.706
+1 86 0.003 0.997
+1 31 0.013 0.987
+1 87 0.002 0.998
+1
~
=ZIONSOLlJTJONSLLc-
,..,ErawSCIMionlCompany
FSS RELEASE RECORD, REV 1 PENETRATIONS SURVEY UNITS 01112, 02112 and 05120
[130]
SOF 1-Ws Sign SOF 1-Ws Sign (Ws)
(Ws) 31 0.013 0.987
+1 88 0.004 0.996
+1 32 0.017 0.983
+1 89 0.003 0.997
+1 33 0.019 0.981
+1 90 0.008 0.992
+1 34 0.020 0.980
+1 91 0.007 0.993
+1 35 0.021 0.979
+1 92 0.002 0.998
+1 36 0.001 0.999
+1 93 0.002 0.998
+1 37 0.001 0.999
+1 94 0.005 0.995
+1 38 0.001 0.999
+1 95 0.005 0.995
+1 39 0.016 0.984
+1 96 0.005 0.995
+1 40 0.016 0.984
+1 97 0.002 0.998
+1 41 0.018 0.982
+1 98 0.003 0.997
+1 42 0.024 0.976
+1 99 0.004 0.996
+1 43 0.026 0.974
+1 100 0.002 0.998
+1 44 0.031 0.969
+1 101 0.001 0.999
+1 45 0.012 0.988
+1 102 0.002 0.998
+1 46 0.012 0.988
+1 103 0.003 0.997
+1 47 0.013 0.987
+1 104 0.002 0.998
+1 48 0.012 0.988
+1 105 0.002 0.998
+1 49 0.015 0.985
+1 106 0.002 0.998
+1 50 0.014 0.986
+1 107 0.002 0.998
+1 51 0.016 0.984
+1 108 0.003 0.997
+1 52 0.014 0.986
+1 109 0.003 0.997
+1 53 0.014 0.986
+1 110 0.002 0.998
+1 54 0.011 0.989
+1 111 0.002 0.998
+1 55 0.011 0.989
+1 112 0.004 0.996
+1 56 0.015 0.985
+1 113 0.002 0.998
+1 Number of Positive Differences (S+) =
114 Critical Value =
66 Survey Unit Meets the Acceptance Criteria
~
=ZIONSOLlJTJONSLLc-
,..,ErawSCIMionlCompany
[131]
ATTACHMENT 4 QC DATA
FSS RELEASE RECORD, REV 1 AUXILIARY BUILDING PENETRATIONS SURVEY UNIT 05120
[132]
Replicate Measurement Assessment Form Survey Unit #
01112 Survey Unit Name Unit 1 Containment Penetrations Sample Plan #
S1-01112A-F Sample
Description:
Comparison of replicate measurements collected from measurement locations P017, P022, P035 (8 ft, 22 ft, 36 ft), P036 (16 ft, 28 ft, 40 ft), P037 (13 ft, 22 ft, 41 ft), P056 (4.5 ft),
P103 (4.5 ft), P123 (7 ft, 23 ft, 38 ft) and P124 (8 ft, 24 ft, 42 ft)
STANDARD COMPARISON ID Activity Value
+20%
-20%
ID Activity Value Acceptable (Y/N)
(pCi/m2)
(pCi/m2)
(pCi/m2)
(pCi/m2)
P017 7.78E+04 9.34E+04 6.23E+04 P017 1.01E+05 N
P022 6.32E+05 7.58E+05 5.06E+05 P022 QC 5.33E+05 Y
P035 8' 2.39E+06 2.87E+06 1.91E+06 P035 8' QC 2.40E+06 Y
P035 22' 2.10E+06 2.52E+06 1.68E+06 P035 22' QC 2.12E+06 Y
P035 36' 2.49E+06 2.99E+06 1.99E+06 P035 36' QC 2.43E+06 Y
P036 16' 2.14E+06 2.57E+06 1.71E+06 P036 16' QC 2.13E+06 Y
P036 28' 2.05E+06 2.46E+06 1.64E+06 P036 28' QC 2.02E+06 Y
P036 40' 2.35E+06 2.82E+06 1.88E+06 P036 40' QC 2.46E+06 Y
P037 13' 2.14E+06 2.57E+06 1.72E+06 P037 13' QC 2.15E+06 Y
P037 22' 2.13E+06 2.55E+06 1.70E+06 P037 22' QC 2.10E+06 Y
P037 41' 2.42E+06 2.91E+06 1.94E+06 P037 41' QC 2.35E+06 Y
P056 4.5' 7.16E+06 8.60E+06 5.73E+06 P056 4.5' QC 4.68E+06 N
P103 4.5' 5.71E+06 6.85E+06 4.57E+06 P103 4.5' QC 5.46E+06 Y
P123 7' 4.18E+06 5.01E+06 3.34E+06 P123 7' QC 4.95E+06 Y
P123 23' 9.16E+06 1.10E+07 7.33E+06 P123 23' QC 9.24E+06 Y
P123 38' 1.18E+08 1.42E+08 9.45E+07 P123 38' QC 1.20E+08 Y
P124 8' 2.94E+06 3.52E+06 2.35E+06 P124 8' QC 2.92E+06 Y
P124 24' 4.85E+06 5.83E+06 3.88E+06 P124 24' QC 4.81E+06 Y
Comments/Corrective Actions: There was acceptable agreement between the standard measurement and the replicate measurement with the exception of pipes P017 and P056-4.5 ft. In these comparisons, the standard result was ~35% greater than the comparison. In accordance with section 4.1.2 of the QAPP, based on the professional judgment of the Radiological Engineer, the same conclusion was reached for each measurement. No further action is necessary.
The acceptance criteria for replicate static measurements and scan surveys are that the same conclusion is reached for each measurement. This is defined as + 20% of the standard.
~
= ZIONSOLlJTJONSLLc-
""E-oySolifion,Compat,y
FSS RELEASE RECORD, REV 1 AUXILIARY BUILDING PENETRATIONS SURVEY UNIT 05120
[133]
Replicate Measurement Assessment Form Survey Unit #
02112 Survey Unit Name Unit 2 Containment Penetrations Sample Plan #
S1-02112A-F Sample
Description:
Comparison of replicate measurements collected from measurement locations P254, P242, P237 (15 ft, 35 ft, 45 ft), P236 (15 ft, 27 ft, 41 ft), P235 (17 ft, 32 ft, 44 ft), P323 (13 ft, 27 ft, 41 ft), P324 (13 ft, 26 ft, 40 ft), P287, P203 and P267 STANDARD COMPARISON ID Activity Value
+20%
-20%
ID Activity Value Acceptable (Y/N)
(pCi/m2)
(pCi/m2)
(pCi/m2)
(pCi/m2)
P254, 4' 8.19E+05 9.83E+05 6.55E+05 P254, 4' QC 8.21E+05 Y
P242, 4' 9.49E+05 1.14E+06 7.59E+05 P242, 4' QC 9.49E+05 Y
P237, 15' 2.29E+06 2.75E+06 1.83E+06 P237, 15' QC 2.31E+06 Y
P237, 35' 2.00E+06 2.40E+06 1.60E+06 P237, 35' QC 2.03E+06 Y
P237, 45' 2.00E+06 2.39E+06 1.60E+06 P237, 45' QC 2.02E+06 Y
P236 15' 2.21E+06 2.65E+06 1.77E+06 P236 15' QC 2.23E+06 Y
P236, 27' 2.04E+06 2.44E+06 1.63E+06 P236, 27' QC 1.97E+06 Y
P236, 41' 2.01E+06 2.42E+06 1.61E+06 P236, 41' QC 2.02E+06 Y
P235, 17' 2.31E+06 2.77E+06 1.85E+06 P235, 17' QC 2.38E+06 Y
P235, 32' 1.99E+06 2.39E+06 1.59E+06 P235, 32' QC 2.09E+06 Y
P235, 44' 2.07E+06 2.48E+06 1.65E+06 P235, 44' QC 2.07E+06 Y
P323, 13' 2.75E+06 3.30E+06 2.20E+06 P323, 13' QC 2.77E+06 Y
P323, 27' 2.82E+06 3.39E+06 2.26E+06 P323, 27' QC 2.81E+06 Y
P323, 41' 2.53E+06 3.04E+06 2.02E+06 P323, 41' QC 2.51E+06 Y
P324, 13' 2.50E+06 3.00E+06 2.00E+06 P324, 13' QC 2.47E+06 Y
P324, 26' 3.85E+06 4.63E+06 3.08E+06 P324, 26' QC 2.55E+06 N
P324 40' 2.26E+06 2.71E+06 1.81E+06 P324 40' QC 2.27E+06 Y
P287, 4' 3.50E+06 4.20E+06 2.80E+06 P287, 4' QC 3.53E+06 Y
P203, 4' 1.94E+06 2.32E+06 1.55E+06 P203, 4' QC 1.89E+06 Y
P267 7.24E+04 8.69E+04 5.79E+04 P267 QC 7.44E+04 Y
Comments/Corrective Actions: There was acceptable agreement between the standard measurement and the replicate measurement with the exception of pipe P324-26 ft. While the replicate measurement did fall out of the +20% range, the detector successfully passed the post use response check. The discrepancy was attributed to differing geometry. In accordance with section 4.1.2 of the QAPP, based on the professional judgment of the Radiological Engineer, the same conclusion was reached for each measurement. No further action is necessary.
The acceptance criteria for replicate static measurements and scan surveys are that the same conclusion is reached for each measurement. This is defined as + 20% of the standard.
~
= ZIONSOLlJTJONSLLc-
""E-oySolifion,Compat,y
FSS RELEASE RECORD, REV 1 AUXILIARY BUILDING PENETRATIONS SURVEY UNIT 05120
[134]
Replicate Measurement Assessment Form Survey Unit #
05120 Survey Unit Name Auxiliary Building Penetrations Sample Plan #
S1-05120A-F Sample
Description:
Comparison of replicate gross-gamma measurements for QC from A002, position 1, A010, position 2, A014, position 3, A021, position 2 and A025 position 3.
STANDARD DUPLICATE ID ACTIVITY
+20%
-20%
ID ACTIVITY ACCEPTABLE (pCi/m2)
(pCi/m2)
(pCi/m2)
(pCi/m2)
(Y/N)
A014 Position 3 3.36E+04 4.04E+04 2.69E+04 A014 Position 3 QC 2.90E+04 Y
A025 Position 3 2.94E+04 3.53E+04 2.35E+04 A025 Position 3 QC 2.40E+04 Y
A021 Position 2 4.64E+05 5.56E+05 3.71E+05 A021 Position 2 QC 4.66E+05 Y
A002 Position 1 4.32E+05 5.18E+05 3.46E+05 A002 Position 1 QC 4.81E+05 Y
A010 Position 2 7.12E+05 8.54E+05 5.69E+05 A010 Position 2 QC 7.21E+05 Y
Comments/Corrective Actions: There was acceptable agreement between the standard measurement and the duplicate measurement. No further action is necessary.
The acceptance criteria for replicate static measurements and scan surveys is that the same conclusion is reached for each measurement. That is defined as + 20% of the standard
~
= ZIONSOLlJTJONSLLc-
""E-oySolifion,Compat,y
[135]
ATTACHMENT 5 GRAPHICAL PRESENTATIONS
FSS RELEASE RECORD, REV 1 PENETRATIONS SURVEY UNITS 01112, 02112 and 05120
[136]
Unit 1 Containment Penetrations (interface with Auxiliary Building and Turbine Building)
Quantile Plot for Co-60 Mean: 6.89E+05 pCi/m2 Median: 1.53E+05 pCi/m2 Standard Deviation: 1.70E+06 pCi/m2 Skew: 3.817 Histogram for Co-60 Upper Value Observation Frequency Observation %
1.05E+06 324 88%
2.10E+06 7
2%
3.15E+06 16 4%
4.20E+06 3
1%
5.24E+06 4
1%
6.29E+06 1
0%
7.34E+06 4
1%
8.39E+06 6
2%
9.44E+06 1
0%
1.05E+07 3
1%
TOTAL 369 100%
0.00E+00 2.00E+06 4.00E+06 6.00E+06 8.00E+06 1.00E+07 1.20E+07 0%
20%
40%
60%
80%
100%
Concentration (pCi/m2)
Percentage Quantile Plot For Co-60 0%
20%
40%
60%
80%
100%
1.05E+06 3.15E+06 5.24E+06 7.34E+06 9.44E+06 Frequency Upper End Value (pCi/m2)
Frequency Plot For Co-60
~
=ZIONSOLUTIONSuc-AnEr,e,gy~Compaoy j
~ ii
FSS RELEASE RECORD, REV 1 PENETRATIONS SURVEY UNITS 01112, 02112 and 05120
[137]
Unit 1 Containment Penetrations (interface with Auxiliary Building and Turbine Building)
Quantile Plot for Cs-137 Mean: 9.95E+06 pCi/m2 Median: 2.22E+06 pCi/m2 Standard Deviation: 2.46E+07 pCi/m2 Skew: 3.817 Histogram for Cs-137 Upper Value Observation Frequency Observation %
1.52E+07 324 88%
3.03E+07 7
2%
4.54E+07 16 4%
6.06E+07 3
1%
7.57E+07 4
1%
9.09E+07 1
0%
1.06E+08 4
1%
1.21E+08 6
2%
1.36E+08 1
0%
1.51E+08 3
1%
TOTAL 369 100%
0.00E+00 2.00E+06 4.00E+06 6.00E+06 8.00E+06 1.00E+07 1.20E+07 0%
20%
40%
60%
80%
100%
Concentration (pCi/m2)
Percentage Quantile Plot For Cs-137 0%
20%
40%
60%
80%
100%
1.52E+07 4.54E+07 7.57E+07 1.06E+08 1.36E+08 Frequency Upper End Value (pCi/m2)
Frequency Plot For Cs-137
~
=ZIONSOLUTIONSuc-AnEr,e,gy~Compaoy
~
~
I~
IJ
FSS RELEASE RECORD, REV 1 PENETRATIONS SURVEY UNITS 01112, 02112 and 05120
[138]
Unit 2 Containment Penetrations (interface with Auxiliary Building and Turbine Building)
Quantile Plot for Co-60 Mean: 1.48E+05 pCi/m2 Median: 1.37E+05 pCi/m2 Standard Deviation: 1.10E+05 pCi/m2 Skew: 2.679 Histogram for Co-60 Upper Value Observation Frequency Observation %
8.51E+04 86 23%
1.69E+05 202 55%
2.52E+05 50 14%
3.36E+05 13 4%
4.19E+05 7
2%
5.03E+05 4
1%
5.86E+05 2
1%
6.70E+05 1
0%
7.53E+05 2
1%
8.37E+05 2
1%
TOTAL 369 100%
0.00E+00 2.00E+06 4.00E+06 6.00E+06 8.00E+06 1.00E+07 1.20E+07 0%
20%
40%
60%
80%
100%
Concentration (pCi/m2)
Percentage Quantile Plot For Co-60 0%
20%
40%
60%
80%
100%
1.05E+06 3.15E+06 5.24E+06 7.34E+06 9.44E+06 Frequency Upper End Value (pCi/m2)
Frequency Plot For Co-60
~
=ZIONSOLUTIONSuc-AnEr,e,gy~Compaoy j *
.1111,
~.
~
FSS RELEASE RECORD, REV 1 PENETRATIONS SURVEY UNITS 01112, 02112 and 05120
[139]
Unit 2 Containment Penetrations (interface with Auxiliary Building and Turbine Building)
Quantile Plot for Cs-137 Mean: 2.13E+06 pCi/m2 Median: 1.98E+06 pCi/m2 Standard Deviation: 1.59E+06 pCi/m2 Skew: 2.679 Histogram for Cs-137 Upper Value Observation Frequency Observation %
1.23E+06 86 23%
2.44E+06 202 55%
3.64E+06 50 14%
4.85E+06 13 4%
6.05E+06 7
2%
7.26E+06 4
1%
8.47E+06 2
1%
9.67E+06 1
0%
1.09E+07 2
1%
1.21E+07 2
1%
TOTAL 369 100%
0.00E+00 2.00E+06 4.00E+06 6.00E+06 8.00E+06 1.00E+07 1.20E+07 0%
20%
40%
60%
80%
100%
Concentration (pCi/m2)
Percentage Quantile Plot For Cs-137 0%
20%
40%
60%
80%
100%
1.52E+07 4.54E+07 7.57E+07 1.06E+08 1.36E+08 Frequency Upper End Value (pCi/m2)
Frequency Plot For Cs-137
~
=ZIONSOLUTIONSuc-AnEr,e,gy~Compaoy
.ti 0
,P I~
II_
FSS RELEASE RECORD, REV 1 PENETRATIONS SURVEY UNITS 01112, 02112 and 05120
[140]
Auxiliary Building Penetrations (interface with Turbine Building)
Quantile Plot for Co-60 Mean: 1.37E+04 pCi/m2 Median: 5.47E+03 pCi/m2 Standard Deviation: 2.93E+04 pCi/m2 Skew: 3.600 Histogram for Co-60 Upper Value Observation Frequency Observation %
1.49E+04 59 89%
2.92E+04 1
2%
4.35E+04 0
0%
5.79E+04 0
0%
7.22E+04 3
5%
8.65E+04 0
0%
1.01E+05 0
0%
1.15E+05 0
0%
1.30E+05 2
3%
1.44E+05 1
2%
TOTAL 66 100%
0.00E+00 2.00E+06 4.00E+06 6.00E+06 8.00E+06 1.00E+07 1.20E+07 0%
20%
40%
60%
80%
100%
Concentration (pCi/m2)
Percentage Quantile Plot For Co-60 0%
10%
20%
30%
40%
50%
60%
70%
80%
90%
100%
1.05E+06 3.15E+06 5.24E+06 7.34E+06 9.44E+06 Frequency Upper End Value (pCi/m2)
Frequency Plot For Co-60
~
=ZIONSOLUTIONSuc-AnEr,e,gy~Compaoy
.P 411.,
~
IJJ
.I
FSS RELEASE RECORD, REV 1 PENETRATIONS SURVEY UNITS 01112, 02112 and 05120
[141]
Auxiliary Building Penetrations (interface with Turbine Building)
Quantile Plot for Cs-137 Mean: 2.13E+06 pCi/m2 Median: 1.98E+06 pCi/m2 Standard Deviation: 1.59E+06 pCi/m2 Skew: 2.679 Histogram for Cs-137 Upper Value Observation Frequency Observation %
1.22E+06 59 89%
2.39E+06 1
2%
3.56E+06 0
0%
4.74E+06 0
0%
5.91E+06 2
3%
7.08E+06 1
2%
8.26E+06 0
0%
9.43E+06 0
0%
1.06E+07 2
3%
1.18E+07 1
2%
TOTAL 66 100%
0.00E+00 2.00E+06 4.00E+06 6.00E+06 8.00E+06 1.00E+07 1.20E+07 0%
20%
40%
60%
80%
100%
Concentration (pCi/m2)
Percentage Quantile Plot For Cs-137 0%
20%
40%
60%
80%
100%
1.52E+07 4.54E+07 7.57E+07 1.06E+08 1.36E+08 Frequency Upper End Value (pCi/m2)
Frequency Plot For Cs-137
~
=ZIONSOLUTIONSuc-AnEr,e,gy~Compaoy j
4111.,
.I IJJ IJ