{{#Wiki_filter:Attachment 2 FSS AREA ACCESS REQUEST, AUTHORIZATION AND SIGN-IN SHEET ZS-LT-300-001-003 Revision 6 Infonnation Use REQUEST FOR ACCESS: Survey Area No.: 12000 Survey Unit No.: 12112A Survey Unit Type: OpenLand[gj Structure D System D Work Group

Contact:

Final Status Survey (FSS), supervisor Radio RP-3. Description of Planned Activities: This is the 1st Bi-annual surveillance survey for this survey unit. Duration: Start 7/30/19 Stop 7/30/19 Access Controls Required:

1. All personnel will brief and sign in/out on this FSS Attachment 2.
2. All personnel and equipment will be surveyed into the area by the FSS technician.
3. There will be one scheduled biased surface soil sample taken in this survey unit.
4. When job is completed, the survey unit postings will be verified s * ~facto 0

Survey Name Reason for Entry Date Time Time Unit# (Pnnt/Sign) In Out 12112A Karen Nicholson/ l<v..-tL ~'V,ch./k_,". FSS technician 7-30-19 /'-/'.OS I s:cl Jn

r
:

15.oo 1s*.J5" / i.,hv1-e, S--pro~ T 7.3,./C, Page I of 3 FSS l&C Surveillance Summary AREA SURVEILLANCE: Survey Area No.: Survey Unit No.:

== Description:== Performing 1st Bi-Annual surveillance survey. Survey Unit Type: Structure 0 ZS-LT-300-001-003 Revision 6 Information Use 12112A SystemO Classification: Open Land 18] Class3 0 Class2 0 Class 1 ~ Reason for Surveillance: Semi-Annual 18] Special D Surveillance Due Date: 7-17-19 Reason: Bi-annual Surveillance survey. (Survey Date surveillance performed: 7-30-19 performed after due date because the storage and removal of the CCDD pile in survey area 12205). SURVEILLANCE ACTIVITIES: I) Review ZS-LT-300-001-003 Attachment 2, PSS Area Access Request, Authorization and Sign-In Sheet for authorized entries into the FSS Survey Unit-------*------------------------------------------------*----------------------------****----- IZ!

2) Perform a walk down of the FSS Survey Unit and identify decommissioning activities adjacent survey units that could have a reasonable potential to spread radioactive material to the FSS Survey Unit.---------------- ~

SURVEILLANCE COMMENTS AND OBSERVATIONS: This survey unit was accessible after the removal of the CCDD pile. The FSS technician contacted the MBI foreman (N. Friant) for support, entered the survey unit to perform the walk down and select the sample locations. The MBI laborer support will join the FSS technician when they become available_ 14:55 The FSS technician received MBI laborer support (Tim C) and setup at the first biased surface soil sample location. 15:00 Collected biased surface soil sample #Ll 12112AVJGS001SS.

== Description:== light/medium brown sand, and gravel. Location was taken on the footprint of a small piece of metal that was removed from survey unit. The metal was surveyed, result, indistinguishable from background. 15:10 Collected biased surface soil sample #Lll2112AVJGS002SS.

== Description:== light/medium brown sand, and gravel. Location selected at tire marks and water mark area. 15:25 Completed surveillance survey. The group signed out of the survey unit. The collected samples were brought to the sample prep trailer for processing. Notes: The sample locations were GPS'd, and the corrected coordinate with the location will be shown on the attached map. There were some small pieces of plastic and metal, water bottles, and some old flags surveyed and removed from the survey unit. The postings were satisfactory. The postings are represented on the adjacent FSS survey units. A Model 3 #283273 with a 44-9/PR355602, cal due 1-24-20 was used for all the surveying. All survey results were indistin 'shable from back ound. Back ound 30-50 c m. - Surveillance Satisfactory 0 -Surveillance Un-Satisfactory Karen N1cholson/ ~ /\\, { t 9-26-19 15:30 fil1-4> ~ \\ te _ LC* \\.._.. (Print Name/Signature) C/LT Technician (Date) (Time)

0.... .... ;z 0 In co

ti 343740 343800

.. '..-~;*.: i:. ,~;,1(' --*--*. ----...... ~.. *- ----------- ------ -~~~

  • ,'*:/*

-~,,. -- "*--.~~- N r" ,~ 30 Feet A ZI~ 0 10Me1ers . :_'?\\\\~?;1 ;::--:'.. Legend

  • :07; :.:*,.

Final Status Survey Surveillance 12112 D

.--\\ **; *.-"

NAD83 IL State Plane East 1201 (Meters) Survey Unit (SU) 12112

  • * ~- *

.,,*.i-2017 Aerials - ~ake CountyG/S DepL __ _

?\\/~-

.. ~~ 0 Biased Surface samples Date performed: 07/30/2019 -~_~-.-_{~_-._' _ D_r_aw_in_g_: ___ F_s_s_1_2_1_1_2_s_U_R_V_0_7_30_1_9 _ ___,

1:29:50PM 8/6/2019 Page 1 of 7 L1-12112A-VJGS-001SS 06-Aug-19-10047 Analysis Report for GAMMA SPECTRUM ANALYSIS Sample Description Sample Identification 06-Aug-19-10047 L1-12112A-VJGS-001SS Sample Type Soil Unit Sample Point Sample Size Peak Locate Threshold Peak Locate Range (in channels) Peak Area Range (in channels) Identification Energy Tolerance Sample Taken On Acquisition Started Live Time Real Time Energy Calibration Used Done On Efficiency Calibration Used Done On 1.514E+03 grams 1.000 keV 120 - 8192 120 - 8192 Detector Name 900.3 seconds 900.0 seconds 1/24/2019 8/6/2019 P11314 7/30/2019 3:00:00PM 8/6/2019 1:14:32PM Dead Time Efficiency Calibration Description 0.03 % Sample Number

78556 Facility Procedure Default 130G_SOIL_1 Administrator Operator 3.00 Geometry 130G_SOIL_1 Fill Height 1513.62 gram Certificate Name Certificate Date Eu155-Na22 12/22/2008 12:00:00PM 120 8192 Peak Analysis To Channel Peak Analysis From Channel Peak Analysis Performed on PEAK ANALYSIS REPORT 8/6/2019 1:29:41PM

~~~pex-Gamma

Page 2 of 7 8/6/2019 1:29:50PM Analysis Report for L1-12112A-VJGS-001SS 06-Aug-19-10047 Peak No. ROI start ROI end (keV) Energy FWHM (keV) Counts Continuum Uncertainty Net Area Area Net Peak Peak Centroid 1 14.03 1.79E+02 975 4.76E+01 M 949 954.75 238.79 1.07 2 7.69 3.84E+01 975 4.46E+01 m 949 968.25 242.17 1.08 3 12.50 5.93E+01 1186 3.87E+01 1175 1180.81 295.38 1.23 4 13.91 1.19E+02 1414 2.59E+01 1400 1406.78 351.94 1.02 5 10.06 7.26E+01 2336 1.04E+01 2323 2330.21 583.02 1.27 6 11.97 8.32E+01 2440 2.28E+01 2428 2434.22 609.05 0.91 7 9.35 3.80E+01 3646 1.70E+01 3632 3640.01 910.64 0.65 8 19.41 3.63E+02 5850 3.28E+00 5826 5837.78 1459.96 1.76 9 5.48 3.00E+01 7060 0.00E+00 7045 7053.07 1763.50 0.52 Errors quoted at 1.000sigma M = First peak in a multiplet region m = Other peak in a multiplet region F = Fitted singlet No background subtract performed on this spectrum. NUCLIDE IDENTIFICATION REPORT Nuclide Library Used C:\\Canberra\\Apex\\Root\\Default\\Library\\ZION LIB-BNL.NLB IDENTIFIED NUCLIDES Id Yield(%) Activity (pCi/grams) Activity Nuclide Name Confidence (keV) Energy Uncertainty 8.16E+00 5.62E-01 K-40 0.88 10.66 1460.82 1.10E-01 1.65E-02 Tl-208 0.99 85.00 583.19 Pb-212 0.99 0.60 115.18 2.85E-01 3.21E-02 43.60 238.63 3.30 300.09 2.42E-01 3.77E-02 Bi-214 0.97 45.49 609.32 4.89 768.36 1.26 806.18

Page 3 of 7 8/6/2019 1:29:50PM Analysis Report for L1-12112A-VJGS-001SS 06-Aug-19-10047 Id Yield(%) Activity (pCi/grams) Activity Nuclide Name Confidence (keV) Energy Uncertainty 3.11 934.06 Bi-214 0.97 14.92 1120.29 1.63 1155.21 5.83 1238.12 1.43 1280.98 3.99 1377.67 0.79 1385.31 1.33 1401.52 2.39 1407.99 2.13 1509.21 1.05 1661.27 2.88 1729.59 5.44E-01 1.02E-01 15.30 1764.49 2.03 1847.43 1.16 2118.51 3.70E-01 7.98E-02 Pb-214 0.99 7.25 241.99 2.54E-01 5.73E-02 18.42 295.22 3.00E-01 4.25E-02 35.60 351.93 1.06 785.96 Ac-228 0.98 2.42 129.07 3.89 209.25 3.46 270.24 2.95 328.00 11.27 338.32 1.92 409.46 4.40 463.00 4.25 794.95 2.56E-01 6.40E-02 25.80 911.20 4.99 964.77 15.80 968.97 3.22 1588.20 = Energy line found in the spectrum. Nuclide confidence index threshold = 0.30 Errors quoted at 1.000sigma Energy Tolerance : 1.000 keV = Energy line not used for Weighted Mean Activity = Manually added nuclide. = Manually edited nuclide. ? INTERFERENCE CORRECTED REPORT

Page 4 of 7 8/6/2019 1:29:50PM Analysis Report for L1-12112A-VJGS-001SS 06-Aug-19-10047 Nuclide Name Nuclide (pCi/grams) Wt mean Activity Comments Confidence Wt mean Activity Uncertainty Id 8.16E+00 5.62E-01 K-40 0.888 1.10E-01 1.65E-02 Tl-208 0.996 X Bi-211 0.886 2.85E-01 3.21E-02 Pb-212 0.996 2.78E-01 3.53E-02 Bi-214 0.974 2.97E-01 3.14E-02 Pb-214 0.998 2.56E-01 6.40E-02 Ac-228 0.985 Errors quoted at 1.000sigma nuclide contains energy lines not used in Weighted Mean Activity = X = nuclide rejected by the interference analysis nuclide is part of an undetermined solution =

? 

Page 5 of 7 8/6/2019 1:29:50PM Analysis Report for L1-12112A-VJGS-001SS 06-Aug-19-10047 UNIDENTIFIED PEAKS Peak Locate Performed on Peak Locate From Channel Peak Locate To Channel 8/6/2019 1:29:41PM 8192 120 Peak No. Energy (keV) Peak Size (CPS) Peak CPS (%) Uncertainty Peak Type Tolerance Nuclide All peaks were identified. Errors quoted at 1.000sigma F = Fitted singlet m = Other peak in a multiplet region M = First peak in a multiplet region

C:\\Canberra\\Apex\\Root\\Default\\Library\\ZION LIB-BNL.NLB Nuclide Library Used NUCLIDE MDA REPORT Line MDA (pCi/grams)

Yield(%) Nuclide Name Nuclide MDA (pCi/grams) Activity (pCi/grams) (keV) Energy An Pk 7.50E-02 6.29E-02 6.29E-02 511.00 100.00 BE-7 6.37E-02 4.30E-01 4.30E-01 477.60 10.44 + K-40 8.16E+00 3.51E-01 3.51E-01 1460.82 10.66 Mn-54 -3.82E-02 4.13E-02 4.13E-02 834.85 99.98 Co-60 -1.19E-02 5.69E-02 6.93E-02 1173.23 99.85 -3.35E-02 5.69E-02 1332.49 99.98 Nb-94 1.36E-02 4.10E-02 4.90E-02 702.65 99.81 -1.69E-02 4.10E-02 871.09 99.89 Ag-108m 8.03E-01 4.16E-02 1.32E+00 79.13 6.60 -5.19E-03 4.16E-02 433.94 90.50 -4.85E-02 6.36E-02 614.28 89.80 -1.88E-02 4.47E-02 722.94 90.80 Sb-125 1.03E-01 1.22E-01 4.48E-01 176.31 6.84 3.36E-01 2.50E+00 380.45 1.52 -2.99E-02 1.22E-01 427.87 29.60 1.17E-01 3.85E-01 463.36 10.49 -5.37E-02 2.42E-01 600.60 17.65 1.90E+00 1.54E+00 606.71 4.98 1.91E-01 3.61E-01 635.95 11.22

Page 6 of 7 8/6/2019 1:29:50PM Analysis Report for L1-12112A-VJGS-001SS 06-Aug-19-10047 Line MDA (pCi/grams) Yield(%) Nuclide Name Nuclide MDA (pCi/grams) Activity (pCi/grams) (keV) Energy 1.03E+00 2.57E+00 671.44 1.79 Sb-125 1.22E-01 Ba-133 2.11E+00 6.69E-02 3.19E+00 79.61 2.65 -4.20E-01 2.00E-01 81.00 32.90 -2.04E-01 4.43E-01 276.40 7.16 3.07E-02 1.82E-01 302.85 18.34 -1.45E-02 6.69E-02 356.01 62.05 -2.43E-01 4.22E-01 383.85 8.94 Cs-134 2.08E+00 6.47E-02 2.89E+00 475.36 1.48 -2.39E-01 5.13E-01 563.25 8.34 -1.44E-02 2.26E-01 569.33 15.37 -4.01E-02 6.99E-02 604.72 97.62 1.23E-02 6.47E-02 795.86 85.46 1.60E-01 6.19E-01 801.95 8.69 2.86E+00 5.79E+00 1038.61 0.99 -1.30E+00 3.65E+00 1167.97 1.79 -3.97E-01 1.77E+00 1365.19 3.02 Cs-137 7.44E-02 6.32E-02 6.32E-02 661.66 85.10 Eu-152 -2.77E-02 1.12E-01 1.12E-01 121.78 28.67 7.05E-02 5.44E-01 244.70 7.61 1.16E+01 1.07E+01 295.94 0.45 -2.94E-02 1.34E-01 344.28 26.60 -1.96E+00 3.89E+00 367.79 0.86 7.61E-01 1.79E+00 411.12 2.24 3.37E-01 1.30E+00 443.96 2.83 -3.48E+00 8.22E+00 488.68 0.42 -6.03E+00 7.67E+00 563.99 0.49 -6.23E+00 1.40E+01 586.26 0.46 -1.78E+00 8.53E+00 678.62 0.47 1.91E+00 4.73E+00 688.67 0.86 -1.41E+01 1.32E+01 719.35 0.28 -1.42E-01 2.87E-01 778.90 12.96 -1.20E+01 1.13E+01 810.45 0.32 2.74E-01 1.00E+00 867.37 4.26 -2.99E+00 1.23E+01 919.33 0.43 3.17E-01 4.62E-01 964.08 14.65 3.13E-01 6.27E-01 1085.87 10.24 -5.88E-01 3.63E+00 1089.74 1.73 -1.74E-01 3.76E-01 1112.07 13.69 4.43E+00 5.58E+00 1212.95 1.43 -1.67E+01 2.88E+01 1249.94 0.19 -1.63E+00 3.30E+00 1299.14 1.63 -4.94E-02 2.24E-01 1408.01 21.07 1.75E+02 4.54E+01 1457.64 0.50 1.76E+00 8.52E+00 1528.10 0.28 Eu-154 3.34E-02 8.03E-02 8.03E-02 123.07 40.40 2.58E-01 5.09E-01 247.93 6.89 -1.64E-01 8.71E-01 591.76 4.95 -1.01E+00 2.33E+00 692.42 1.78 -1.13E-01 2.03E-01 723.30 20.06 -1.65E-02 1.05E+00 756.80 4.52 -4.04E-01 3.32E-01 873.18 12.08

Page 7 of 7 8/6/2019 1:29:50PM Analysis Report for L1-12112A-VJGS-001SS 06-Aug-19-10047 Line MDA (pCi/grams) Yield(%) Nuclide Name Nuclide MDA (pCi/grams) Activity (pCi/grams) (keV) Energy 1.82E-01 4.91E-01 996.29 10.48 Eu-154 8.03E-02 1.11E-01 2.87E-01 1004.76 18.01 -8.63E-02 1.71E-01 1274.43 34.80 -6.54E-01 1.79E+00 1596.48 1.80 Eu-155 -5.48E+00 1.98E-01 1.16E+01 45.30 1.31 2.00E+00 1.30E+01 60.01 1.22 6.74E-02 1.99E-01 86.55 30.70 6.98E-02 1.98E-01 105.31 21.10 Ra-226 9.30E-01 1.01E+00 1.01E+00 186.21 3.64 Pa-231 9.66E-01 1.38E+00 1.38E+00 27.36 10.30 1.41E+00 2.27E+00 283.69 1.70 -7.36E-01 1.42E+00 300.07 2.47 2.70E-01 1.51E+00 302.65 2.20 -6.81E-02 2.52E+00 330.06 1.40 U-235 -8.87E-02 6.42E-02 3.24E-01 143.76 10.96 4.27E-01 6.94E-01 163.33 5.08 4.62E-02 6.42E-02 185.71 57.20 -3.32E-01 2.93E+00 202.11 1.08 -5.72E-01 6.38E-01 205.31 5.01 Am-241 2.49E-02 4.45E-01 4.45E-01 59.54 35.90

+ 
= Nuclide identified during the nuclide identification Energy line found in the spectrum
= 
= MDA value not calculated Half-life too short to be able to perform the decay correction
= 
? 
= CAUTION: MDA value is inconsistent with Currie MDA at 95% confidence level

1:29:54PM 8/6/2019 Page 1 of 7 L1-12112A-VJGS-002SS 06-Aug-19-10048 Analysis Report for GAMMA SPECTRUM ANALYSIS Sample Description Sample Identification 06-Aug-19-10048 L1-12112A-VJGS-002SS Sample Type Soil Unit Sample Point Sample Size Peak Locate Threshold Peak Locate Range (in channels) Peak Area Range (in channels) Identification Energy Tolerance Sample Taken On Acquisition Started Live Time Real Time Energy Calibration Used Done On Efficiency Calibration Used Done On 1.202E+03 grams 1.000 keV 120 - 8192 120 - 8192 Detector Name 900.3 seconds 900.0 seconds 9/29/2018 8/6/2019 352 7/30/2019 3:10:00PM 8/6/2019 1:14:40PM Dead Time Efficiency Calibration Description 0.03 % Sample Number

78557 Facility Procedure Default 130G_SOIL_1 Administrator Operator 3.00 Geometry 130G_SOIL_1 Fill Height 1201.93 gram Certificate Name Certificate Date Eu155-Na22 1/7/2013 12:00:00PM 120 8192 Peak Analysis To Channel Peak Analysis From Channel Peak Analysis Performed on PEAK ANALYSIS REPORT 8/6/2019 1:29:46PM

~~~pex-Gamma

Page 2 of 7 8/6/2019 1:29:54PM Analysis Report for L1-12112A-VJGS-002SS 06-Aug-19-10048 Peak No. ROI start ROI end (keV) Energy FWHM (keV) Counts Continuum Uncertainty Net Area Area Net Peak Peak Centroid 1 12.59 2.14E+01 304 6.36E+01 296 301.15 74.96 0.61 2 11.94 3.00E+01 748 4.90E+01 739 744.92 186.05 0.92 3 20.16 1.97E+02 961 7.02E+01 946 955.43 238.74 1.15 4 13.21 8.37E+01 1187 3.43E+01 1175 1180.69 295.12 1.29 5 10.27 2.51E+01 1360 3.09E+01 1349 1353.19 338.29 0.91 6 16.03 1.33E+02 1416 3.82E+01 1399 1407.76 351.94 1.15 7 10.27 6.37E+01 1916 1.53E+01 1903 1909.93 477.59 1.18 8 11.27 8.27E+01 2339 1.63E+01 2326 2331.53 583.05 0.42 9 12.27 9.96E+01 2445 1.64E+01 2429 2436.57 609.32 1.08 10 7.88 3.05E+01 2653 1.25E+01 2642 2646.53 661.84 0.41 11 5.26 2.01E+01 3079 2.89E+00 3068 3073.98 768.73 1.49 12 8.87 5.16E+01 3650 9.40E+00 3636 3643.96 911.23 1.10 13 6.30 2.86E+01 3880 4.43E+00 3869 3874.83 968.94 0.33 14 21.15 4.06E+02 5855 9.70E+00 5830 5843.00 1460.66 1.83 Errors quoted at 1.000sigma M = First peak in a multiplet region m = Other peak in a multiplet region F = Fitted singlet No background subtract performed on this spectrum. NUCLIDE IDENTIFICATION REPORT Nuclide Library Used C:\\Canberra\\Apex\\Root\\Default\\Library\\ZION LIB-BNL.NLB IDENTIFIED NUCLIDES Id Yield(%) Activity (pCi/grams) Activity Nuclide Name Confidence (keV) Energy Uncertainty 7.62E-01 1.34E-01 BE-7 1.00 10.44 477.60 9.22E+00 6.25E-01 K-40 0.99 10.66 1460.82 5.09E-02 1.35E-02 Cs-137 0.99 85.10 661.66

Page 3 of 7 8/6/2019 1:29:54PM Analysis Report for L1-12112A-VJGS-002SS 06-Aug-19-10048 Id Yield(%) Activity (pCi/grams) Activity Nuclide Name Confidence (keV) Energy Uncertainty 1.27E-01 1.89E-02 Tl-208 0.99 85.00 583.19 Pb-212 0.99 0.60 115.18 3.26E-01 4.25E-02 43.60 238.63 3.30 300.09 3.82E-01 2.28E-01 Pb212-XR 0.99 10.28 74.82 17.10 77.11 3.97 87.35 1.46 89.78 2.93E-01 4.02E-02 Bi-214 0.99 45.49 609.32 6.44E-01 1.72E-01 4.89 768.36 1.26 806.18 3.11 934.06 14.92 1120.29 1.63 1155.21 5.83 1238.12 1.43 1280.98 3.99 1377.67 0.79 1385.31 1.33 1401.52 2.39 1407.99 2.13 1509.21 1.05 1661.27 2.88 1729.59 15.30 1764.49 2.03 1847.43 1.16 2118.51 Pb-214 0.99 7.25 241.99 3.69E-01 6.53E-02 18.42 295.22 3.44E-01 4.98E-02 35.60 351.93 1.06 785.96 6.78E-01 4.06E-01 Pb214-XR 0.99 5.80 74.82 9.70 77.11 2.24 87.35 0.82 89.78 5.30E-01 2.15E-01 Ra-226 0.99 3.64 186.21 Ac-228 1.00 2.42 129.07 3.89 209.25 3.46 270.24 2.95 328.00 2.00E-01 8.32E-02 11.27 338.32 1.92 409.46 4.40 463.00 4.25 794.95 3.51E-01 6.23E-02 25.80 911.20 4.99 964.77 3.31E-01 7.44E-02 15.80 968.97 3.22 1588.20 U-235 0.98 10.96 143.76 5.08 163.33 3.37E-02 1.37E-02 57.20 185.71 1.08 202.11 5.01 205.31

Page 4 of 7 8/6/2019 1:29:54PM Analysis Report for L1-12112A-VJGS-002SS 06-Aug-19-10048 = Energy line found in the spectrum. Nuclide confidence index threshold = 0.30 Errors quoted at 1.000sigma Energy Tolerance : 1.000 keV = Energy line not used for Weighted Mean Activity = Manually added nuclide. = Manually edited nuclide. ? INTERFERENCE CORRECTED REPORT Nuclide Name Nuclide (pCi/grams) Wt mean Activity Comments Confidence Wt mean Activity Uncertainty Id 7.62E-01 1.34E-01 BE-7 1.000 9.22E+00 6.25E-01 K-40 0.996 5.09E-02 1.35E-02 Cs-137 0.995 1.27E-01 1.89E-02 Tl-208 0.997 X Bi-211 0.886 3.26E-01 4.25E-02 Pb-212 0.998 3.82E-01 2.28E-01 ? Pb212-XR 0.999 3.12E-01 3.92E-02 Bi-214 0.999 3.53E-01 3.96E-02 Pb-214 0.999 6.78E-01 4.06E-01 ? Pb214-XR 0.999 5.30E-01 2.15E-01 ? Ra-226 0.996 3.07E-01 4.14E-02 Ac-228 1.000 3.37E-02 1.37E-02 ? U-235 0.987 Errors quoted at 1.000sigma nuclide contains energy lines not used in Weighted Mean Activity = X = nuclide rejected by the interference analysis nuclide is part of an undetermined solution =

? 

Page 5 of 7 8/6/2019 1:29:54PM Analysis Report for L1-12112A-VJGS-002SS 06-Aug-19-10048 UNIDENTIFIED PEAKS Peak Locate Performed on Peak Locate From Channel Peak Locate To Channel 8/6/2019 1:29:46PM 8192 120 Peak No. Energy (keV) Peak Size (CPS) Peak CPS (%) Uncertainty Peak Type Tolerance Nuclide All peaks were identified. Errors quoted at 1.000sigma F = Fitted singlet m = Other peak in a multiplet region M = First peak in a multiplet region

C:\\Canberra\\Apex\\Root\\Default\\Library\\ZION LIB-BNL.NLB Nuclide Library Used NUCLIDE MDA REPORT Line MDA (pCi/grams)

Yield(%) Nuclide Name Nuclide MDA (pCi/grams) Activity (pCi/grams) (keV) Energy An Pk 5.55E-02 6.44E-02 6.44E-02 511.00 100.00 + BE-7 7.62E-01 2.97E-01 2.97E-01 477.60 10.44 + K-40 9.22E+00 5.59E-01 5.59E-01 1460.82 10.66 Mn-54 9.19E-03 5.95E-02 5.95E-02 834.85 99.98 Co-60 4.32E-02 4.86E-02 6.99E-02 1173.23 99.85 -9.81E-04 4.86E-02 1332.49 99.98 Nb-94 -5.61E-03 5.23E-02 5.23E-02 702.65 99.81 9.93E-03 5.52E-02 871.09 99.89 Ag-108m -1.06E+00 5.07E-02 1.56E+00 79.13 6.60 8.43E-03 5.07E-02 433.94 90.50 -4.26E-02 8.86E-02 614.28 89.80 -2.69E-02 5.92E-02 722.94 90.80 Sb-125 -5.20E-02 1.60E-01 5.90E-01 176.31 6.84 1.48E+00 2.58E+00 380.45 1.52 -5.91E-02 1.60E-01 427.87 29.60 2.04E-01 4.54E-01 463.36 10.49 5.48E-02 2.45E-01 600.60 17.65 2.71E+00 1.60E+00 606.71 4.98 -6.49E-02 4.59E-01 635.95 11.22

Page 6 of 7 8/6/2019 1:29:54PM Analysis Report for L1-12112A-VJGS-002SS 06-Aug-19-10048 Line MDA (pCi/grams) Yield(%) Nuclide Name Nuclide MDA (pCi/grams) Activity (pCi/grams) (keV) Energy -1.08E+00 2.90E+00 671.44 1.79 Sb-125 1.60E-01 Ba-133 8.95E-01 9.80E-02 3.87E+00 79.61 2.65 -4.98E-01 2.75E-01 81.00 32.90 9.29E-02 5.78E-01 276.40 7.16 2.07E-02 2.20E-01 302.85 18.34 -8.37E-03 9.80E-02 356.01 62.05 -4.23E-01 4.49E-01 383.85 8.94 Cs-134 3.51E+00 5.98E-02 4.05E+00 475.36 1.48 4.71E-02 5.04E-01 563.25 8.34 1.97E-01 3.09E-01 569.33 15.37 -3.28E-02 7.25E-02 604.72 97.62 1.09E-02 5.98E-02 795.86 85.46 -3.34E-01 5.36E-01 801.95 8.69 3.23E+00 6.61E+00 1038.61 0.99 -5.95E-02 3.95E+00 1167.97 1.79 -9.59E-02 1.55E+00 1365.19 3.02 + Cs-137 5.09E-02 3.65E-02 3.65E-02 661.66 85.10 Eu-152 -1.47E-02 1.48E-01 1.48E-01 121.78 28.67 2.25E-01 6.05E-01 244.70 7.61 1.50E+01 1.22E+01 295.94 0.45 -5.06E-02 1.48E-01 344.28 26.60 -7.72E-01 4.49E+00 367.79 0.86 -8.34E-01 2.02E+00 411.12 2.24 1.14E-01 1.50E+00 443.96 2.83 1.44E+00 9.57E+00 488.68 0.42 1.34E+00 8.72E+00 563.99 0.49 2.06E+01 1.66E+01 586.26 0.46 4.21E+00 1.11E+01 678.62 0.47 -2.83E+00 4.94E+00 688.67 0.86 -2.69E+00 1.79E+01 719.35 0.28 1.16E-01 3.71E-01 778.90 12.96 9.27E-01 1.47E+01 810.45 0.32 -2.70E-01 1.26E+00 867.37 4.26 -7.48E+00 1.36E+01 919.33 0.43 1.11E-01 5.47E-01 964.08 14.65 2.92E-01 6.10E-01 1085.87 10.24 -2.05E+00 3.88E+00 1089.74 1.73 -3.03E-01 4.46E-01 1112.07 13.69 -9.91E-01 5.06E+00 1212.95 1.43 -4.86E+01 3.81E+01 1249.94 0.19 1.35E+00 3.54E+00 1299.14 1.63 5.31E-02 2.66E-01 1408.01 21.07 1.97E+02 4.89E+01 1457.64 0.50 -9.11E+00 1.21E+01 1528.10 0.28 Eu-154 -5.57E-03 1.03E-01 1.03E-01 123.07 40.40 5.52E-02 5.75E-01 247.93 6.89 -2.82E-02 9.79E-01 591.76 4.95 2.25E-01 2.43E+00 692.42 1.78 1.95E-01 2.81E-01 723.30 20.06 4.17E-01 9.86E-01 756.80 4.52 -5.95E-02 4.64E-01 873.18 12.08

Page 7 of 7 8/6/2019 1:29:54PM Analysis Report for L1-12112A-VJGS-002SS 06-Aug-19-10048 Line MDA (pCi/grams) Yield(%) Nuclide Name Nuclide MDA (pCi/grams) Activity (pCi/grams) (keV) Energy 4.32E-01 5.71E-01 996.29 10.48 Eu-154 1.03E-01 -5.13E-02 3.62E-01 1004.76 18.01 -6.47E-02 1.87E-01 1274.43 34.80 -2.27E+00 2.81E+00 1596.48 1.80 Eu-155 1.08E+01 2.52E-01 2.41E+01 45.30 1.31 -8.28E+00 2.41E+01 60.01 1.22 -1.06E-01 2.74E-01 86.55 30.70 -8.49E-02 2.52E-01 105.31 21.10 + Ra-226 5.30E-01 6.86E-01 6.86E-01 186.21 3.64 Pa-231 2.09E+00 1.82E+00 2.78E+00 27.36 10.30 4.95E-01 2.26E+00 283.69 1.70 -1.49E-01 1.82E+00 300.07 2.47 -5.24E-01 1.82E+00 302.65 2.20 -1.31E+00 2.72E+00 330.06 1.40 + U-235 -2.73E-01 4.37E-02 3.81E-01 143.76 10.96 6.20E-02 7.89E-01 163.33 5.08 3.37E-02 4.37E-02 185.71 57.20 3.68E-01 3.65E+00 202.11 1.08 -1.29E+00 7.73E-01 205.31 5.01 Am-241 -4.98E-01 8.39E-01 8.39E-01 59.54 35.90

+ 
= Nuclide identified during the nuclide identification Energy line found in the spectrum
= 
= MDA value not calculated Half-life too short to be able to perform the decay correction
= 
? 
= CAUTION: MDA value is inconsistent with Currie MDA at 95% confidence level FSS AREA ACCESS REQUEST, AUTHORIZATION AND SIGN-IN SHEET ZS-LT-300-001-003 Revision 6 Information Use REQUEST FOR ACCESS:

Survey Area No.: 12000 Survey Unit No.: 12113A Survey Unit Type: Open Land IZ! Structure D System D Work Group

Contact:

The Final Status Survey (FSS) supervisor, Radio RP-3. Description of Planned Activities: The FSS technician and MBI laborer support are performing the 1st Bi-annual surveillance in this survey unit 12113A. Duration: Start 9-6-19 Stop 9-6-19 Access Controls Required:

1. All personnel will brief and sign in/out on this FSS Attachment 2.
2. All personnel and equipment will be surveyed into the area by the FSS technician.
3. There will be a minimum of one scheduled biased surface soil sample taken in this survey unit.
4. When job is completed, the survey unit postings will be verified satisfactory.

Approved: Ji BfJtu4,;__. Survey Name Reason for Entry Date Time Time Unit# (Print/Sign) In Out 12113A Karen Nicholson!f °"'-...,_JV l *~ FSS technician 9-6-19 /3'..30 J<t. 1/5 l L. 1\\.9 12113A Rudy Diaz/ -~ ~ MBI laborer support 9-6-19 ,~- 3 0 / Y. l/5 12113A Tony Ortega/ ~,(/~- MBI laborer support 9-6-19 13 :3o }l-J. 'if" /'


*- ---. --~--- ----

-.............. ~----........ A /V *-------------......__*-..,, '***~ -............ ~........... FSS l&C Surveillance Summary AREA SURVEILLANCE: Survey Area No.: 12000 Survey Unit No.:

== Description:== Performing 1st Bi-Annual surveillance survey. Survey Unit Type: Structure 0 ZS-LT-300-001-003 Revision 6 Information Use 12113A System 0 Classification: Open Land~ Class 3 0 Class 2 0 Class 1 ~ Reason for Surveillance: Semi-Annual~ Special 0 Surveillance Due Date: 7-16-19 Reason: Bi-annual Surveillance survey. (Survey Date surveillance performed: 9-6-19 performed after due date because the storage and removal of the CCDD pile in the adjacent survey area 12205). SURVEILLANCE ACTIVITIES: l) Review ZS-LT-300-001-003 Attachment 2, FSS Area Access Request, Authorization and Sign-In Sheet for authorized entries into the FSS Survey Unit--**********--**-**********-**-********-*-**********--*************--*-********--************* ~

2) Perform a walk down of the FSS Survey Unit and identify decommissioning activities adjacent survey units that could have a reasonable potential to spread radioactive material to the FSS Survey Unit.**************** [gj SURVEILLANCE COMMENTS AND OBSERVATIONS:

This survey unit was part of the traverse path to remove the CCDD pile. The CCDD is now removed, and the surveillance survey is being performed. The FSS technician will perform the planned surveillance survey (walk down and sample), but will also include a gamma walk over survey on the traverse path. 13:30 The FSS technician and the MBI laborer support (RD, TO) contacted the MBI foreman (N. Friant), and signed into the survey unit. All personnel and sampling equipment was_~~eyed in. .._-,--::-::-=-~::-:----,::-:--,-,--,----,.....,...-,---.,,..,...-- 13 :40 Scan Area backgrounds: 2936, 2833, 2905, 2122, and 2094 cpm, AVG 2578 cpm, MDCR 543 cpm, and ASP 3121 cpm. 14:14 Collected biased surface soil sample #Ll 12113AVJGS001SS.

== Description:== medium brown sand, and gravel. Location selected at a dried flooded area. 14:22 Collected biased surface soil sample #Ll 12113AVJGS002SS.

== Description:== medium brown sand, and gravel. Location selected at tire marks flooded area. 14:45 Completed surveillance survey. The group signed out of the survey unit. The collected samples were brought to the sample prep trailer for processing. Notes: The sample locations and the scan area was GPS 'd, and the corrected coordinate with the location will be shown on the attached map. The meter used for the scan area was a Model 2350-1/ #304708 with a 44-10 probe #PR321892 (with 3" collimator), cal due 9-4-20. The scan results were no detectable above background/no alarms. The 2350-1 meter passed pre and post source check. There were some small pieces of plastic and metal that was surveyed and removed from the survey unit. The postings were satisfactory. The postings are represented on the adjacent FSS survey units. A Model 3 #284300 with a 44-9/PR308400, cal due 1-24-20 was used for all the surve

  • ng. All survey results were indistin ishable from background. Back ound 30-50 c m.

~- Surveillance Satisfactory 0- Surveillance Un-Satisfactory (Print Name/S' a re) C/LT (Date) (Time) /1) - Pt,-/ (Date) (Time)

0.....

g 0

tO CD v CD 343710 I f ' ' I 1 i ! *~ I I i._:, / /

  • L 112113AVJ0s0<>1ss*
~641693.13....

343 723.61 '~.. l I j Legend I I / I I ~ D Survey Unit (SU) 12113 0 Biased Surface Samples '. *** --1 Scan Area 343740 N A 125 2li Fee!

  • .5 0Me1em Final Status Survey Surveillance 12113 NAD83 IL State Plane East 1201 (Meters) 2017 Aerials - Lake County GIS Dept Date performed:

09/06/2019 Drawing: FSS12113 SURV

10:15:06AM 9/9/2019 Page 1 of 7 L1-12113A-VJGS-001SS 09-Sep-19-10015 Analysis Report for GAMMA SPECTRUM ANALYSIS Sample Description Sample Identification 09-Sep-19-10015 L1-12113A-VJGS-001SS Sample Type Soil Unit Sample Point Sample Size Peak Locate Threshold Peak Locate Range (in channels) Peak Area Range (in channels) Identification Energy Tolerance Sample Taken On Acquisition Started Live Time Real Time Energy Calibration Used Done On Efficiency Calibration Used Done On 1.558E+03 grams 1.000 keV 120 - 4096 120 - 4096 Detector Name 900.4 seconds 900.0 seconds 9/29/2018 9/9/2019 324 9/6/2019 2:14:00PM 9/9/2019 9:59:56AM Dead Time Efficiency Calibration Description 0.04 % Sample Number

79343 Facility Procedure Default 130G_SOIL_1 Administrator Operator 3.00 Geometry 130G_SOIL_1 Fill Height 1558.48 gram Certificate Name Certificate Date Eu155-Na22 1/30/2013 12:00:00PM 120 4096 Peak Analysis To Channel Peak Analysis From Channel Peak Analysis Performed on PEAK ANALYSIS REPORT 9/9/2019 10:14:59AM

~~~pex-Gamma

Page 2 of 7 9/9/2019 10:15:06AM Analysis Report for L1-12113A-VJGS-001SS 09-Sep-19-10015 Peak No. ROI start ROI end (keV) Energy FWHM (keV) Counts Continuum Uncertainty Net Area Area Net Peak Peak Centroid 1 22.68 1.54E+02 481 1.52E+02 472 477.28 238.55 0.96 2 15.68 7.40E+01 595 7.10E+01 585 590.43 295.19 1.33 3 15.88 1.11E+02 708 6.25E+01 699 703.58 351.82 0.93 4 10.27 5.75E+01 1025 2.25E+01 1017 1020.25 510.28 1.18 5 11.86 8.01E+01 1171 2.39E+01 1160 1166.23 583.31 1.54 6 13.39 1.17E+02 1223 2.63E+01 1213 1218.09 609.25 1.68 7 4.68 8.44E+00 2478 7.56E+00 2473 2475.84 1238.08 1.07 8 21.95 4.71E+02 2928 3.71E+00 2914 2921.40 1460.67 1.53 Errors quoted at 1.000sigma M = First peak in a multiplet region m = Other peak in a multiplet region F = Fitted singlet No background subtract performed on this spectrum. NUCLIDE IDENTIFICATION REPORT Nuclide Library Used C:\\Canberra\\Apex\\Root\\Default\\Library\\ZION LIB-BNL.NLB IDENTIFIED NUCLIDES Id Yield(%) Activity (pCi/grams) Activity Nuclide Name Confidence (keV) Energy Uncertainty 5.97E-02 1.14E-02 An Pk 0.92 100.00 511.00 8.81E+00 5.61E-01 K-40 0.99 10.66 1460.82 1.03E-01 1.64E-02 Tl-208 0.99 85.00 583.19 Pb-212 0.99 0.60 115.18 2.15E-01 3.61E-02 43.60 238.63 3.30 300.09 2.88E-01 3.73E-02 Bi-214 1.00 45.49 609.32 4.89 768.36 1.26 806.18

Page 3 of 7 9/9/2019 10:15:06AM Analysis Report for L1-12113A-VJGS-001SS 09-Sep-19-10015 Id Yield(%) Activity (pCi/grams) Activity Nuclide Name Confidence (keV) Energy Uncertainty 3.11 934.06 Bi-214 1.00 14.92 1120.29 1.63 1155.21 2.57E-01 1.43E-01 5.83 1238.12 1.43 1280.98 3.99 1377.67 0.79 1385.31 1.33 1401.52 2.39 1407.99 2.13 1509.21 1.05 1661.27 2.88 1729.59 15.30 1764.49 2.03 1847.43 1.16 2118.51 Pb-214 0.99 7.25 241.99 2.76E-01 6.25E-02 18.42 295.22 2.41E-01 3.97E-02 35.60 351.93 1.06 785.96 = Energy line found in the spectrum. Nuclide confidence index threshold = 0.30 Errors quoted at 1.000sigma Energy Tolerance : 1.000 keV = Energy line not used for Weighted Mean Activity = Manually added nuclide. = Manually edited nuclide. ? INTERFERENCE CORRECTED REPORT Nuclide Name Nuclide (pCi/grams) Wt mean Activity Comments Confidence Wt mean Activity Uncertainty Id 5.97E-02 1.14E-02 An Pk 0.920 8.81E+00 5.61E-01 K-40 0.996 1.03E-01 1.64E-02 Tl-208 0.997 X Bi-211 0.915 2.15E-01 3.61E-02 Pb-212 0.999 2.86E-01 3.61E-02 Bi-214 1.000 2.51E-01 3.35E-02 Pb-214 0.999

Page 4 of 7 9/9/2019 10:15:06AM Analysis Report for L1-12113A-VJGS-001SS 09-Sep-19-10015 Errors quoted at 1.000sigma nuclide contains energy lines not used in Weighted Mean Activity = X = nuclide rejected by the interference analysis nuclide is part of an undetermined solution =

? 

Page 5 of 7 9/9/2019 10:15:06AM Analysis Report for L1-12113A-VJGS-001SS 09-Sep-19-10015 UNIDENTIFIED PEAKS Peak Locate Performed on Peak Locate From Channel Peak Locate To Channel 9/9/2019 10:14:59AM 4096 120 Peak No. Energy (keV) Peak Size (CPS) Peak CPS (%) Uncertainty Peak Type Tolerance Nuclide All peaks were identified. Errors quoted at 1.000sigma F = Fitted singlet m = Other peak in a multiplet region M = First peak in a multiplet region

C:\\Canberra\\Apex\\Root\\Default\\Library\\ZION LIB-BNL.NLB Nuclide Library Used NUCLIDE MDA REPORT Line MDA (pCi/grams)

Yield(%) Nuclide Name Nuclide MDA (pCi/grams) Activity (pCi/grams) (keV) Energy + An Pk 5.97E-02 2.74E-02 2.74E-02 511.00 100.00 BE-7 3.64E-01 4.56E-01 4.56E-01 477.60 10.44 + K-40 8.81E+00 2.61E-01 2.61E-01 1460.82 10.66 Mn-54 2.85E-02 4.50E-02 4.50E-02 834.85 99.98 Co-60 7.35E-03 5.10E-02 6.03E-02 1173.23 99.85 2.00E-02 5.10E-02 1332.49 99.98 Nb-94 6.74E-03 3.30E-02 4.37E-02 702.65 99.81 -3.89E-02 3.30E-02 871.09 99.89 Ag-108m 4.20E-01 3.55E-02 1.25E+00 79.13 6.60 -2.06E-02 3.55E-02 433.94 90.50 -4.73E-02 5.65E-02 614.28 89.80 2.27E-02 5.36E-02 722.94 90.80 Sb-125 -1.19E-01 1.19E-01 5.00E-01 176.31 6.84 6.50E-01 2.27E+00 380.45 1.52 7.10E-02 1.19E-01 427.87 29.60 4.60E-02 3.33E-01 463.36 10.49 -2.46E-02 2.39E-01 600.60 17.65 -2.89E-01 1.48E+00 606.71 4.98 -9.64E-02 3.35E-01 635.95 11.22

Page 6 of 7 9/9/2019 10:15:06AM Analysis Report for L1-12113A-VJGS-001SS 09-Sep-19-10015 Line MDA (pCi/grams) Yield(%) Nuclide Name Nuclide MDA (pCi/grams) Activity (pCi/grams) (keV) Energy -1.09E+00 2.12E+00 671.44 1.79 Sb-125 1.19E-01 Ba-133 1.29E-01 7.69E-02 2.91E+00 79.61 2.65 -2.45E-01 1.99E-01 81.00 32.90 1.42E-01 4.59E-01 276.40 7.16 -4.71E-03 1.87E-01 302.85 18.34 -2.16E-02 7.69E-02 356.01 62.05 -6.46E-02 3.92E-01 383.85 8.94 Cs-134 3.16E+00 4.90E-02 3.22E+00 475.36 1.48 2.63E-01 4.50E-01 563.25 8.34 -1.24E-01 2.16E-01 569.33 15.37 -8.70E-03 6.66E-02 604.72 97.62 8.20E-03 4.90E-02 795.86 85.46 -2.54E-01 4.52E-01 801.95 8.69 -2.60E+00 4.90E+00 1038.61 0.99 6.33E-01 3.22E+00 1167.97 1.79 6.30E-01 1.14E+00 1365.19 3.02 Cs-137 4.46E-02 5.54E-02 5.54E-02 661.66 85.10 Eu-152 1.26E-02 1.20E-01 1.20E-01 121.78 28.67 -6.13E-02 5.19E-01 244.70 7.61 -1.20E+00 9.68E+00 295.94 0.45 -9.18E-02 1.29E-01 344.28 26.60 -1.20E+00 3.72E+00 367.79 0.86 6.93E-01 1.77E+00 411.12 2.24 -2.24E-01 1.16E+00 443.96 2.83 2.35E+00 7.52E+00 488.68 0.42 2.49E+00 7.47E+00 563.99 0.49 -5.57E+00 1.27E+01 586.26 0.46 1.43E+00 8.68E+00 678.62 0.47 -7.18E-02 4.54E+00 688.67 0.86 8.47E-01 1.49E+01 719.35 0.28 8.90E-02 3.46E-01 778.90 12.96 -3.60E-01 1.21E+01 810.45 0.32 -1.44E-01 8.07E-01 867.37 4.26 -3.27E+00 1.13E+01 919.33 0.43 -3.86E-01 4.11E-01 964.08 14.65 1.02E-01 4.99E-01 1085.87 10.24 2.60E-01 3.15E+00 1089.74 1.73 -1.30E-01 3.93E-01 1112.07 13.69 -3.79E+00 3.69E+00 1212.95 1.43 -5.72E+00 2.88E+01 1249.94 0.19 -4.51E-01 2.80E+00 1299.14 1.63 2.16E-02 1.98E-01 1408.01 21.07 -1.85E+00 4.28E+01 1457.64 0.50 -6.22E+00 9.12E+00 1528.10 0.28 Eu-154 -2.09E-02 8.15E-02 8.15E-02 123.07 40.40 9.93E-02 4.97E-01 247.93 6.89 1.35E-02 8.04E-01 591.76 4.95 -7.70E-01 2.12E+00 692.42 1.78 7.87E-02 2.43E-01 723.30 20.06 3.28E-01 9.51E-01 756.80 4.52 4.41E-03 3.21E-01 873.18 12.08

Page 7 of 7 9/9/2019 10:15:06AM Analysis Report for L1-12113A-VJGS-001SS 09-Sep-19-10015 Line MDA (pCi/grams) Yield(%) Nuclide Name Nuclide MDA (pCi/grams) Activity (pCi/grams) (keV) Energy -1.32E-01 4.56E-01 996.29 10.48 Eu-154 8.15E-02 -5.81E-02 2.60E-01 1004.76 18.01 3.65E-02 1.49E-01 1274.43 34.80 3.16E-01 2.05E+00 1596.48 1.80 Eu-155 4.99E+00 1.78E-01 1.24E+01 45.30 1.31 -6.77E+00 1.25E+01 60.01 1.22 2.82E-02 1.92E-01 86.55 30.70 -6.41E-03 1.78E-01 105.31 21.10 Ra-226 4.54E-01 1.07E+00 1.07E+00 186.21 3.64 Pa-231 2.12E-01 1.10E+00 1.10E+00 27.36 10.30 -5.88E-02 1.89E+00 283.69 1.70 3.55E-01 1.38E+00 300.07 2.47 -3.92E-02 1.55E+00 302.65 2.20 1.12E+00 2.67E+00 330.06 1.40 U-235 -6.59E-02 6.77E-02 3.01E-01 143.76 10.96 -1.09E-01 6.98E-01 163.33 5.08 2.73E-02 6.77E-02 185.71 57.20 -2.17E+00 3.13E+00 202.11 1.08 -6.90E-01 6.63E-01 205.31 5.01 Am-241 -8.34E-02 4.46E-01 4.46E-01 59.54 35.90

+ 
= Nuclide identified during the nuclide identification Energy line found in the spectrum
= 
= MDA value not calculated Half-life too short to be able to perform the decay correction
= 
? 
= CAUTION: MDA value is inconsistent with Currie MDA at 95% confidence level

10:15:24AM 9/9/2019 Page 1 of 7 L1-12113A-VJGS-002SS 09-Sep-19-10016 Analysis Report for GAMMA SPECTRUM ANALYSIS Sample Description Sample Identification 09-Sep-19-10016 L1-12113A-VJGS-002SS Sample Type Soil Unit Sample Point Sample Size Peak Locate Threshold Peak Locate Range (in channels) Peak Area Range (in channels) Identification Energy Tolerance Sample Taken On Acquisition Started Live Time Real Time Energy Calibration Used Done On Efficiency Calibration Used Done On 1.635E+03 grams 1.000 keV 120 - 8192 120 - 8192 Detector Name 901.4 seconds 900.0 seconds 1/29/2019 9/9/2019 P40818B 9/6/2019 2:22:00PM 9/9/2019 10:00:07AM Dead Time Efficiency Calibration Description 0.15 % Sample Number

79344 Facility Procedure Default 130G_SOIL_1 Administrator Operator 3.00 Geometry 130G_SOIL_1 Fill Height 1634.92 gram Certificate Name Certificate Date Eu155-Na22 1/30/2012 12:00:00PM 120 8192 Peak Analysis To Channel Peak Analysis From Channel Peak Analysis Performed on PEAK ANALYSIS REPORT 9/9/2019 10:15:10AM

~~~pex-Gamma

Page 2 of 7 9/9/2019 10:15:24AM Analysis Report for L1-12113A-VJGS-002SS 09-Sep-19-10016 Peak No. ROI start ROI end (keV) Energy FWHM (keV) Counts Continuum Uncertainty Net Area Area Net Peak Peak Centroid 1 11.40 3.85E+01 313 4.55E+01 306 308.87 77.04 0.57 2 10.60 2.17E+01 840 3.73E+01 830 836.82 209.16 0.87 3 17.91 1.41E+02 960 6.72E+01 948 954.46 238.59 0.73 4 11.66 7.80E+01 1186 2.30E+01 1175 1179.98 295.02 1.17 5 13.52 1.07E+02 1415 2.64E+01 1401 1407.21 351.87 0.87 6 7.57 2.97E+01 1914 1.13E+01 1904 1908.79 477.34 0.82 7 9.16 6.04E+01 2338 8.61E+00 2325 2332.10 583.22 1.16 8 9.75 6.28E+01 2442 1.13E+01 2428 2435.50 609.08 1.14 9 7.11 3.23E+01 3648 6.69E+00 3636 3642.24 910.82 0.72 10 18.10 2.93E+02 5849 9.93E+00 5830 5840.56 1460.18 1.99 Errors quoted at 1.000sigma M = First peak in a multiplet region m = Other peak in a multiplet region F = Fitted singlet No background subtract performed on this spectrum. NUCLIDE IDENTIFICATION REPORT Nuclide Library Used C:\\Canberra\\Apex\\Root\\Default\\Library\\ZION LIB-BNL.NLB IDENTIFIED NUCLIDES Id Yield(%) Activity (pCi/grams) Activity Nuclide Name Confidence (keV) Energy Uncertainty 3.60E-01 9.53E-02 BE-7 0.98 10.44 477.60 7.17E+00 5.41E-01 K-40 0.93 10.66 1460.82 9.93E-02 1.62E-02 Tl-208 1.00 85.00 583.19 Pb-212 1.00 0.60 115.18 2.49E-01 3.75E-02 43.60 238.63 3.30 300.09 Pb212-XR 1.00 10.28 74.82

Page 3 of 7 9/9/2019 10:15:24AM Analysis Report for L1-12113A-VJGS-002SS 09-Sep-19-10016 Id Yield(%) Activity (pCi/grams) Activity Nuclide Name Confidence (keV) Energy Uncertainty 4.71E-01 1.47E-01 17.10 77.11 Pb212-XR 1.00 3.97 87.35 1.46 89.78 1.98E-01 3.31E-02 Bi-214 0.99 45.49 609.32 4.89 768.36 1.26 806.18 3.11 934.06 14.92 1120.29 1.63 1155.21 5.83 1238.12 1.43 1280.98 3.99 1377.67 0.79 1385.31 1.33 1401.52 2.39 1407.99 2.13 1509.21 1.05 1661.27 2.88 1729.59 15.30 1764.49 2.03 1847.43 1.16 2118.51 Pb-214 0.99 7.25 241.99 3.67E-01 6.22E-02 18.42 295.22 2.94E-01 4.42E-02 35.60 351.93 1.06 785.96 Pb214-XR 1.00 5.80 74.82 8.30E-01 2.63E-01 9.70 77.11 2.24 87.35 0.82 89.78 Ac-228 0.73 2.42 129.07 4.04E-01 2.00E-01 3.89 209.25 3.46 270.24 2.95 328.00 11.27 338.32 1.92 409.46 4.40 463.00 4.25 794.95 2.37E-01 5.31E-02 25.80 911.20 4.99 964.77 15.80 968.97 3.22 1588.20 = Energy line found in the spectrum. Nuclide confidence index threshold = 0.30 Errors quoted at 1.000sigma Energy Tolerance : 1.000 keV = Energy line not used for Weighted Mean Activity = Manually added nuclide. = Manually edited nuclide. ?

Page 4 of 7 9/9/2019 10:15:24AM Analysis Report for L1-12113A-VJGS-002SS 09-Sep-19-10016 INTERFERENCE CORRECTED REPORT Nuclide Name Nuclide (pCi/grams) Wt mean Activity Comments Confidence Wt mean Activity Uncertainty Id 3.60E-01 9.53E-02 BE-7 0.989 7.17E+00 5.41E-01 K-40 0.936 9.93E-02 1.62E-02 Tl-208 1.000 X Bi-211 0.903 2.49E-01 3.75E-02 Pb-212 1.000 4.71E-01 1.47E-01 ? Pb212-XR 1.000 1.98E-01 3.31E-02 Bi-214 0.996 3.19E-01 3.60E-02 Pb-214 0.998 8.30E-01 2.63E-01 ? Pb214-XR 1.000 2.48E-01 5.13E-02 Ac-228 0.731 Errors quoted at 1.000sigma nuclide contains energy lines not used in Weighted Mean Activity = X = nuclide rejected by the interference analysis nuclide is part of an undetermined solution =

? 

Page 5 of 7 9/9/2019 10:15:24AM Analysis Report for L1-12113A-VJGS-002SS 09-Sep-19-10016 UNIDENTIFIED PEAKS Peak Locate Performed on Peak Locate From Channel Peak Locate To Channel 9/9/2019 10:15:10AM 8192 120 Peak No. Energy (keV) Peak Size (CPS) Peak CPS (%) Uncertainty Peak Type Tolerance Nuclide All peaks were identified. Errors quoted at 1.000sigma F = Fitted singlet m = Other peak in a multiplet region M = First peak in a multiplet region

C:\\Canberra\\Apex\\Root\\Default\\Library\\ZION LIB-BNL.NLB Nuclide Library Used NUCLIDE MDA REPORT Line MDA (pCi/grams)

Yield(%) Nuclide Name Nuclide MDA (pCi/grams) Activity (pCi/grams) (keV) Energy An Pk 8.60E-02 6.21E-02 6.21E-02 511.00 100.00 + BE-7 3.60E-01 2.51E-01 2.51E-01 477.60 10.44 + K-40 7.17E+00 5.59E-01 5.59E-01 1460.82 10.66 Mn-54 2.06E-02 5.37E-02 5.37E-02 834.85 99.98 Co-60 5.34E-02 6.18E-02 7.18E-02 1173.23 99.85 2.25E-02 6.18E-02 1332.49 99.98 Nb-94 2.19E-02 4.90E-02 4.90E-02 702.65 99.81 -1.15E-02 5.26E-02 871.09 99.89 Ag-108m -8.15E-01 4.93E-02 1.80E+00 79.13 6.60 3.99E-03 4.93E-02 433.94 90.50 -3.46E-02 5.53E-02 614.28 89.80 7.09E-03 5.70E-02 722.94 90.80 Sb-125 -4.31E-01 1.52E-01 5.87E-01 176.31 6.84 1.03E+00 2.48E+00 380.45 1.52 -1.38E-03 1.52E-01 427.87 29.60 9.07E-02 4.50E-01 463.36 10.49 -2.73E-02 2.36E-01 600.60 17.65 8.81E-01 1.39E+00 606.71 4.98 -1.75E-01 3.74E-01 635.95 11.22

Page 6 of 7 9/9/2019 10:15:24AM Analysis Report for L1-12113A-VJGS-002SS 09-Sep-19-10016 Line MDA (pCi/grams) Yield(%) Nuclide Name Nuclide MDA (pCi/grams) Activity (pCi/grams) (keV) Energy -9.12E-01 2.27E+00 671.44 1.79 Sb-125 1.52E-01 Ba-133 -2.98E+00 7.90E-02 4.17E+00 79.61 2.65 -3.68E-01 2.87E-01 81.00 32.90 5.60E-02 5.59E-01 276.40 7.16 -3.95E-02 2.23E-01 302.85 18.34 1.56E-02 7.90E-02 356.01 62.05 -2.04E-01 4.11E-01 383.85 8.94 Cs-134 1.06E+00 5.33E-02 3.31E+00 475.36 1.48 1.68E-01 5.00E-01 563.25 8.34 -1.49E-01 2.41E-01 569.33 15.37 -1.78E-02 6.81E-02 604.72 97.62 1.76E-02 5.33E-02 795.86 85.46 -7.15E-02 5.07E-01 801.95 8.69 -2.05E-01 6.00E+00 1038.61 0.99 -3.86E-01 4.10E+00 1167.97 1.79 -2.35E+00 1.82E+00 1365.19 3.02 Cs-137 1.05E-02 5.22E-02 5.22E-02 661.66 85.10 Eu-152 -3.55E-02 1.62E-01 1.66E-01 121.78 28.67 5.21E-01 6.70E-01 244.70 7.61 5.16E+00 1.14E+01 295.94 0.45 9.16E-02 1.62E-01 344.28 26.60 7.08E-01 3.91E+00 367.79 0.86 2.88E-01 1.84E+00 411.12 2.24 5.84E-01 1.44E+00 443.96 2.83 1.77E+00 9.92E+00 488.68 0.42 4.96E-01 8.47E+00 563.99 0.49 1.91E-01 1.49E+01 586.26 0.46 7.52E-01 9.71E+00 678.62 0.47 2.83E+00 5.23E+00 688.67 0.86 -1.15E+01 1.61E+01 719.35 0.28 -5.24E-01 3.33E-01 778.90 12.96 1.90E+00 1.43E+01 810.45 0.32 -1.66E+00 1.25E+00 867.37 4.26 2.36E+00 1.13E+01 919.33 0.43 2.46E-01 5.07E-01 964.08 14.65 -1.78E-01 5.16E-01 1085.87 10.24 4.31E-01 3.42E+00 1089.74 1.73 -1.13E-01 4.80E-01 1112.07 13.69 1.15E+00 5.08E+00 1212.95 1.43 2.24E+01 4.24E+01 1249.94 0.19 1.14E-01 3.50E+00 1299.14 1.63 -1.55E-01 2.08E-01 1408.01 21.07 1.57E+02 4.54E+01 1457.64 0.50 -1.33E+01 1.65E+01 1528.10 0.28 Eu-154 2.08E-02 1.20E-01 1.20E-01 123.07 40.40 -1.22E-01 6.18E-01 247.93 6.89 -3.92E-01 8.92E-01 591.76 4.95 -2.56E+00 2.24E+00 692.42 1.78 6.06E-02 2.58E-01 723.30 20.06 -3.92E-01 1.08E+00 756.80 4.52 -2.31E-01 4.01E-01 873.18 12.08

Page 7 of 7 9/9/2019 10:15:24AM Analysis Report for L1-12113A-VJGS-002SS 09-Sep-19-10016 Line MDA (pCi/grams) Yield(%) Nuclide Name Nuclide MDA (pCi/grams) Activity (pCi/grams) (keV) Energy -1.27E-01 4.87E-01 996.29 10.48 Eu-154 1.20E-01 1.17E-01 3.12E-01 1004.76 18.01 -1.13E-01 1.89E-01 1274.43 34.80 3.11E-01 1.50E+00 1596.48 1.80 Eu-155 -3.46E+00 2.76E-01 3.21E+01 45.30 1.31 1.93E-01 3.19E+01 60.01 1.22 6.14E-02 3.04E-01 86.55 30.70 1.60E-02 2.76E-01 105.31 21.10 Ra-226 9.31E-01 1.23E+00 1.23E+00 186.21 3.64 Pa-231 3.59E+00 1.54E+00 3.86E+00 27.36 10.30 -8.58E-01 2.20E+00 283.69 1.70 -2.41E-01 1.54E+00 300.07 2.47 5.47E-01 1.87E+00 302.65 2.20 1.59E+00 3.02E+00 330.06 1.40 U-235 1.76E-01 7.98E-02 4.21E-01 143.76 10.96 1.06E-01 8.09E-01 163.33 5.08 5.94E-02 7.98E-02 185.71 57.20 3.14E+00 3.87E+00 202.11 1.08 1.92E-02 7.62E-01 205.31 5.01 Am-241 -3.45E-01 1.13E+00 1.13E+00 59.54 35.90

+ 
= Nuclide identified during the nuclide identification Energy line found in the spectrum
= 
= MDA value not calculated Half-life too short to be able to perform the decay correction
= 
? 
= CAUTION: MDA value is inconsistent with Currie MDA at 95% confidence level FSS AREA ACCESS REQUEST, AUTHORIZATION AND SIGN-IN SHEET REQUEST FOR ACCESS:

ZS-LT-300-001-003 Revision 6 Information Use Survey Area No.: 12000 Survey Unit No.: 12203A Survey Unit Type: Open Land ~ Structure D System D Work Group

Contact:

Final Status Survey (FSS) contact Radio RP-3. Description of Planned Activities: FSS technician and MBI laborer support are performing the I st Bi-annual Surveillance survey for this survey unit. This survey is also a response to CR#ES-ZION-CR-2019-0066. Duration: Start ------- 6-18-19 Stop 6-18-19 Access.Controls Required:

1.

FSS technician will brief/sign on the Attachment 2 from this procedure ZS-LT-300-001-003.

2.

The personnel that enter the survey unit will perform a hand and foot frisk, and survey any equipment going for surveying.

3.

There will be one biased surface soil sample collected, and a scan survey performed on the snow/dirt pile placed at the west boundary.

4.

Posting will be verified when job is complete. Survey Name Reason for Entry Date Time Time Unit# (Pnnt/Sign) In Out 12203A Karen Nicholson/ Cv1'\\1, \\\\j I J\\,--. FSS technician 6-18-19 i :J " M' f/S 12203A Rudy Diaz/ MBI laborer support 6-18-19 5( : ] i) 1r>:v~ I ~~t-'~f'\\ kITT\\tv l I t.,h ~ ls-... 1,, +SS ~ hl)l(l,V... it ~ */ 9 J '3: ) ~) 1Lj' ~ r I / y-.,1?,iI.. I a...~,., r-'1r S'-'<"r--.iR-+- "-J g-J ~ rr *,r /l ~~s


*-* 1"1 IJ..t /.._J>.Jrf-<

l~~C3ft ':,.-.....,-(0.'L-;- 6*1? iCJ' ,3~.3£" ,1~:cl...\\ n1 ~,,:: l " /b b,r4,'.,-

  • i/o 5-,,,:JF'" (- -J--

fu-/8' I? /S-.' (JU If-: 3 !i / )l iJ_,;J.: / r,_,b,Y -{- 1;).l~ *3 y S'-f'I""',-r ~,(&-17 1{:uo /5* 3 5" f *c lb-/~-,9 kl} re,-, )./1 e,'1~L\\*,,." "'-~' "I fd-cH 1/1

  • kl'"' IC I fl-ll0 15- 00 ts;~

~~¥-- Ii+ -s-

AREA SURVEILLANCE: Survey Area No.: 12000 FSS I&C Surveillance Summary Survey Unit No.: ZS-LT-300-001-003 Revision 6 Information Use 12203A

== Description:== Final Status Survey (FSS) 1st Bi-Annual Surveillance Survey. Survey Unit Type: Classification: OpenLand[gl Class 3 D Reason for Surveillance: Semi-Annual [8'.I Structure D System D Class 2 D Class 1 [8'.I Special~ Surveillance Due Date: 7/10/2019 Reason: 1st Bi-annual Surveillance survey, Date surveillance was performed: 6/18/2019 and response to CR#ES-ZION-CR-2019-0066 SURVEILLANCE ACTIVITIES:, *.

1) Review ZS-LT-300-001-003 Attachment 2, FSS Area Access Request, Authorization and Sign-ln Sheet for authorized entries into the FSS Survey Unit------*---*-----*--*-*----*--------------*----*******-------** [gJ
2) Perform a walk down of the FSS Survey Unit and identify decolillllissioning activities adjacent survey units that could have a reasonable potential to spread radioactive material to the FSS Survey Unit.*--*-------- [gJ SUR\\'EILLANCE COJ\\-IMEN'f~ AND OBSER\\*ATIONS:

8:25 The FSS technician (KN) and MBI laborer support (Rudy D, and Alex V) contacted MBI (N. Friant), signed into and surveyed into the survey unit This survey is the 1st Bi-annual surveillance and a special survey on a pile of dirt staged at the FSS boundary (See attach sheet for special survey instructions for the dirt ile. 08:30 Performed the scan survey on the pile and IO meters square on the perimeter at the track marks. Backgrounds; 3392, 3827, 3559, 3306, and 3481 cpm, average 3513 cpm, MDCR 634 cpm, and ASP 4147 cpm. There were no alarms for all scan results (3" collimator used). There are eight biased surface soil samples collected for the dirt pile area. 09:48 Collected biased surface soil sample #Ll 12203AVJGS001 SS.

== Description:== dark/medium brown sand, and gravel. 10: 10 Collected biased surface soil sample #Ll 12203AVJGS002SS.

== Description:== medium brown sand, gray clay, and gravel. 10:35 Collected biased surface soil sample #Ll 12203AVJGS003S S.

== Description:== medium brown sand, gray clay, and gravel. 13:00 Collected biased surface soil sample #Ll 12203AVJGS004SS.

== Description:== medium brown sand, gray clay, and gravel. 13: 11 Collected biased surface soil sample #LI 12203AVJGS005SS.

== Description:== medium brown sand, gray clay, and gravel. 13: 1 7 Collected biased surface soil sample #L 112203A VJGS006S S.

== Description:== medium brown sand, gray clay, and gravel. 13:26 Collected biased surface soil sample #LI 12203AVJGS007SS.

== Description:== medium brown sand, and gravel. 13:42 Collected biased surface soil sample #LI 12203AVJGS008SS.

== Description:== medium brown sand, and gravel. Completed the special survey for the CR, brought all the samples to sample prep trailer for processing, and then came back to finish the walk down for the surveillance. FSS I&C Surveillance Summary Continuation from page 1. ZS-L T-300-001-003 Re\\ision 6 Information Use 15:00 The FSS technician and the MBI laborer support sign and surveyed back into the survey unit for the walk down. 15:30 Completed survey, there were no anomalies. The flags from FSS survey were removed, an FSS posting was added to the south west entry rope. There was a portion of the survey unit on the west side was not accessible because it was flooded. The west side of this survey unit does abut up to the Power Block survey units 1211 lA, and 12202F that bas had remediation performed recently. The group signed out of the survey unit. Note: The meters used for the survey was a Model 2350-1, 304712 using a 44-10/PR372143, cal due 12-18-19 passed pre and post source check. The Model 3 #284230 with 44-9/361458, cal due 10-18-19. Background 30-50 cpm. The sample locations were GPS'd and the corrected coordinates are shown on attached map. I IZJ-Surveillance Satisfactory I D-Surveillance Un-Satisfactory Karen Nicholson/ J<

-0 ~ -s: + V') Details for the SU 12203A surveillance: Scans and samples along the perimeter of the dirt pile and on the dirt pile (6 samples) 2 random scan and sample areas within areas of obvious heavy machinery landscaping east of dirt pile location (~10 square meters of scan and :; samples along the treadways) Examples below: Perimeter scans & samples and on the dirt pile Heavy Machinery Treadways East of Dirt Pile ~ \\'\\~\\ \\ '\\ )_ \\~

co 0 C") co co 0 co

i 343640 L 112203AVJGS007SS 641626.96 343641.55 L 112203AVJGS005SS 641625.63 343642.53 L112203AVJGS004SS 641623.04 343641.98 t

L 1122D3AV JGS006SS 641622.40 343640.57 Legend D Survey Unit (SU) 12203A 0 Biased Surface Samples L 112203AVJGS003SS 641628.53 343643.44 343650 L112203AVJGS001SS 641626.90 343645.03 L112203AVJG008SS ,~641624.30 343643.70 ~ L112203AVJGS002SS 641621.76 343643.44 ~ ZlONSoLl!llONS 0 10 Feet 1.25 2.5Metere Final Status Survey Surveillance SU12203A ES-ZION-CR-2019-0066 NAD83 JL State Plane East 1201 (Meters) 2017 Aerials - Lake County GJS Dept. Date performed: 06/18/2019 Drawing: FSS SURV12203A 061819

9:46:12AM 6/20/2019 Page 1 of 7 L1-12203A-VJGS-001SS 20-Jun-19-10011 Analysis Report for GAMMA SPECTRUM ANALYSIS Sample Description Sample Identification 20-Jun-19-10011 L1-12203A-VJGS-001SS Sample Type Soil Unit Sample Point Sample Size Peak Locate Threshold Peak Locate Range (in channels) Peak Area Range (in channels) Identification Energy Tolerance Sample Taken On Acquisition Started Live Time Real Time Energy Calibration Used Done On Efficiency Calibration Used Done On 1.284E+03 grams 1.000 keV 120 - 4096 120 - 4096 Detector Name 900.4 seconds 900.0 seconds 9/29/2018 6/20/2019 324 6/18/2019 9:48:00AM 6/20/2019 9:31:02AM Dead Time Efficiency Calibration Description 0.04 % Sample Number

77542 Facility Procedure Default 130G_SOIL_1 Administrator Operator 3.00 Geometry 130G_SOIL_1 Fill Height 1283.78 gram Certificate Name Certificate Date Eu155-Na22 1/30/2013 12:00:00PM 120 4096 Peak Analysis To Channel Peak Analysis From Channel Peak Analysis Performed on PEAK ANALYSIS REPORT 6/20/2019 9:46:04AM

~~~pex-Gamma

Page 2 of 7 6/20/2019 9:46:12AM Analysis Report for L1-12203A-VJGS-001SS 20-Jun-19-10011 Peak No. ROI start ROI end (keV) Energy FWHM (keV) Counts Continuum Uncertainty Net Area Area Net Peak Peak Centroid 1 18.63 2.99E+01 158 1.65E+02 152 155.00 77.20 0.66 2 22.62 1.59E+02 481 1.58E+02 473 477.52 238.67 1.11 3 16.27 1.41E+02 594 5.49E+01 585 590.27 295.11 1.03 4 12.13 6.94E+01 681 3.86E+01 674 676.76 338.39 1.04 5 15.78 1.76E+02 708 3.61E+01 701 703.85 351.95 1.38 6 9.55 1.60E+01 959 3.60E+01 952 955.08 477.67 0.92 7 12.27 7.19E+01 1026 3.31E+01 1016 1021.54 510.93 1.24 8 11.64 7.15E+01 1171 2.55E+01 1160 1166.37 583.38 1.16 9 14.51 1.14E+02 1224 3.62E+01 1212 1218.63 609.53 2.01 10 10.75 7.75E+01 1828 1.45E+01 1816 1822.10 911.32 1.84 11 9.43 3.50E+01 1944 2.10E+01 1933 1937.84 969.19 1.64 12 23.03 5.16E+02 2928 5.28E+00 2915 2921.88 1460.91 2.00 Errors quoted at 1.000sigma M = First peak in a multiplet region m = Other peak in a multiplet region F = Fitted singlet No background subtract performed on this spectrum. NUCLIDE IDENTIFICATION REPORT Nuclide Library Used C:\\Canberra\\Apex\\Root\\Default\\Library\\ZION LIB-BNL.NLB IDENTIFIED NUCLIDES Id Yield(%) Activity (pCi/grams) Activity Nuclide Name Confidence (keV) Energy Uncertainty 7.77E-02 1.43E-02 An Pk 0.99 100.00 511.00 1.59E-01 9.51E-02 BE-7 0.99 10.44 477.60 1.03E+01 6.39E-01 K-40 0.99 10.66 1460.82 9.66E-02 1.68E-02 Tl-208 0.99 85.00 583.19 Pb-212 1.00 0.60 115.18

Page 3 of 7 6/20/2019 9:46:12AM Analysis Report for L1-12203A-VJGS-001SS 20-Jun-19-10011 Id Yield(%) Activity (pCi/grams) Activity Nuclide Name Confidence (keV) Energy Uncertainty 2.31E-01 3.79E-02 43.60 238.63 Pb-212 1.00 3.30 300.09 Pb212-XR 0.99 10.28 74.82 1.99E-01 1.26E-01 17.10 77.11 3.97 87.35 1.46 89.78 2.96E-01 4.17E-02 Bi-214 0.99 45.49 609.32 4.89 768.36 1.26 806.18 3.11 934.06 14.92 1120.29 1.63 1155.21 5.83 1238.12 1.43 1280.98 3.99 1377.67 0.79 1385.31 1.33 1401.52 2.39 1407.99 2.13 1509.21 1.05 1661.27 2.88 1729.59 15.30 1764.49 2.03 1847.43 1.16 2118.51 Pb-214 0.99 7.25 241.99 5.50E-01 7.71E-02 18.42 295.22 4.02E-01 4.83E-02 35.60 351.93 1.06 785.96 Pb214-XR 0.99 5.80 74.82 3.51E-01 2.22E-01 9.70 77.11 2.24 87.35 0.82 89.78 Ac-228 0.99 2.42 129.07 3.89 209.25 3.46 270.24 2.95 328.00 4.87E-01 9.40E-02 11.27 338.32 1.92 409.46 4.40 463.00 4.25 794.95 4.64E-01 6.74E-02 25.80 911.20 4.99 964.77 3.56E-01 9.74E-02 15.80 968.97 3.22 1588.20 = Energy line found in the spectrum. Nuclide confidence index threshold = 0.30 Errors quoted at 1.000sigma Energy Tolerance : 1.000 keV = Energy line not used for Weighted Mean Activity = Manually added nuclide. = Manually edited nuclide. ?

Page 4 of 7 6/20/2019 9:46:12AM Analysis Report for L1-12203A-VJGS-001SS 20-Jun-19-10011 INTERFERENCE CORRECTED REPORT Nuclide Name Nuclide (pCi/grams) Wt mean Activity Comments Confidence Wt mean Activity Uncertainty Id 7.77E-02 1.43E-02 An Pk 0.999 1.59E-01 9.51E-02 BE-7 0.999 1.03E+01 6.39E-01 K-40 0.999 9.66E-02 1.68E-02 Tl-208 0.994 X Bi-211 0.883 2.31E-01 3.79E-02 Pb-212 1.000 1.99E-01 1.26E-01 ? Pb212-XR 0.999 2.96E-01 4.17E-02 Bi-214 0.997 4.44E-01 4.10E-02 Pb-214 0.999 3.51E-01 2.22E-01 ? Pb214-XR 0.999 4.44E-01 4.77E-02 Ac-228 0.998 Errors quoted at 1.000sigma nuclide contains energy lines not used in Weighted Mean Activity = X = nuclide rejected by the interference analysis nuclide is part of an undetermined solution =

? 

Page 5 of 7 6/20/2019 9:46:12AM Analysis Report for L1-12203A-VJGS-001SS 20-Jun-19-10011 UNIDENTIFIED PEAKS Peak Locate Performed on Peak Locate From Channel Peak Locate To Channel 6/20/2019 9:46:04AM 4096 120 Peak No. Energy (keV) Peak Size (CPS) Peak CPS (%) Uncertainty Peak Type Tolerance Nuclide All peaks were identified. Errors quoted at 1.000sigma F = Fitted singlet m = Other peak in a multiplet region M = First peak in a multiplet region

C:\\Canberra\\Apex\\Root\\Default\\Library\\ZION LIB-BNL.NLB Nuclide Library Used NUCLIDE MDA REPORT Line MDA (pCi/grams)

Yield(%) Nuclide Name Nuclide MDA (pCi/grams) Activity (pCi/grams) (keV) Energy + An Pk 7.77E-02 3.56E-02 3.56E-02 511.00 100.00 + BE-7 1.59E-01 3.19E-01 3.19E-01 477.60 10.44 + K-40 1.03E+01 3.15E-01 3.15E-01 1460.82 10.66 Mn-54 -1.69E-02 4.91E-02 4.91E-02 834.85 99.98 Co-60 1.82E-02 6.58E-02 6.77E-02 1173.23 99.85 3.67E-02 6.58E-02 1332.49 99.98 Nb-94 -8.32E-04 4.12E-02 4.12E-02 702.65 99.81 -1.81E-02 4.56E-02 871.09 99.89 Ag-108m -1.94E-01 3.93E-02 1.25E+00 79.13 6.60 -1.40E-02 3.93E-02 433.94 90.50 -8.95E-03 6.73E-02 614.28 89.80 6.29E-03 4.95E-02 722.94 90.80 Sb-125 -1.28E-02 1.22E-01 5.72E-01 176.31 6.84 -7.07E-01 2.49E+00 380.45 1.52 -1.34E-02 1.22E-01 427.87 29.60 2.24E-01 3.99E-01 463.36 10.49 -4.94E-02 2.21E-01 600.60 17.65 -5.66E-02 1.53E+00 606.71 4.98 1.93E-02 3.96E-01 635.95 11.22

Page 6 of 7 6/20/2019 9:46:12AM Analysis Report for L1-12203A-VJGS-001SS 20-Jun-19-10011 Line MDA (pCi/grams) Yield(%) Nuclide Name Nuclide MDA (pCi/grams) Activity (pCi/grams) (keV) Energy -6.51E-01 2.45E+00 671.44 1.79 Sb-125 1.22E-01 Ba-133 -9.56E-01 8.94E-02 2.96E+00 79.61 2.65 -1.44E-01 2.01E-01 81.00 32.90 1.09E-01 5.46E-01 276.40 7.16 4.88E-02 1.95E-01 302.85 18.34 -8.05E-02 8.94E-02 356.01 62.05 4.82E-02 4.16E-01 383.85 8.94 Cs-134 -1.26E+00 5.62E-02 3.00E+00 475.36 1.48 1.01E-01 4.53E-01 563.25 8.34 9.08E-02 2.39E-01 569.33 15.37 -8.61E-03 6.28E-02 604.72 97.62 3.07E-02 5.62E-02 795.86 85.46 -1.03E-01 4.84E-01 801.95 8.69 4.92E-01 5.66E+00 1038.61 0.99 -7.05E-02 3.56E+00 1167.97 1.79 -3.34E-02 1.30E+00 1365.19 3.02 Cs-137 6.09E-02 6.60E-02 6.60E-02 661.66 85.10 Eu-152 -3.74E-02 1.27E-01 1.27E-01 121.78 28.67 -5.61E-02 5.63E-01 244.70 7.61 -3.63E+00 1.17E+01 295.94 0.45 -9.69E-02 1.47E-01 344.28 26.60 8.13E-01 4.30E+00 367.79 0.86 -1.40E-01 1.76E+00 411.12 2.24 -2.27E-01 1.31E+00 443.96 2.83 -3.94E+00 8.45E+00 488.68 0.42 -1.99E+00 7.52E+00 563.99 0.49 -5.17E+00 1.33E+01 586.26 0.46 3.85E-01 9.24E+00 678.62 0.47 2.24E+00 5.02E+00 688.67 0.86 1.07E+00 1.29E+01 719.35 0.28 1.04E-01 3.40E-01 778.90 12.96 4.50E+00 1.32E+01 810.45 0.32 3.46E-02 1.12E+00 867.37 4.26 1.60E-01 1.01E+01 919.33 0.43 -1.54E-01 4.10E-01 964.08 14.65 3.97E-02 5.55E-01 1085.87 10.24 2.21E+00 3.52E+00 1089.74 1.73 -2.27E-02 4.41E-01 1112.07 13.69 -2.71E-01 4.84E+00 1212.95 1.43 4.49E+00 3.30E+01 1249.94 0.19 1.69E-01 3.64E+00 1299.14 1.63 1.52E-01 2.63E-01 1408.01 21.07 -6.23E+00 4.75E+01 1457.64 0.50 -1.87E+00 1.28E+01 1528.10 0.28 Eu-154 2.93E-02 9.38E-02 9.38E-02 123.07 40.40 -7.04E-02 5.20E-01 247.93 6.89 -8.20E-02 8.13E-01 591.76 4.95 1.39E-01 2.35E+00 692.42 1.78 7.65E-02 2.36E-01 723.30 20.06 4.38E-01 1.06E+00 756.80 4.52 2.36E-01 4.03E-01 873.18 12.08

Page 7 of 7 6/20/2019 9:46:12AM Analysis Report for L1-12203A-VJGS-001SS 20-Jun-19-10011 Line MDA (pCi/grams) Yield(%) Nuclide Name Nuclide MDA (pCi/grams) Activity (pCi/grams) (keV) Energy -1.10E-02 4.42E-01 996.29 10.48 Eu-154 9.38E-02 -1.10E-01 2.46E-01 1004.76 18.01 7.41E-02 1.73E-01 1274.43 34.80 -1.68E+00 2.18E+00 1596.48 1.80 Eu-155 1.11E-02 1.96E-01 1.20E+01 45.30 1.31 -6.96E+00 1.39E+01 60.01 1.22 3.72E-02 2.03E-01 86.55 30.70 -7.68E-02 1.96E-01 105.31 21.10 Ra-226 7.64E-01 1.19E+00 1.19E+00 186.21 3.64 Pa-231 1.08E+00 1.36E+00 1.36E+00 27.36 10.30 1.50E-01 2.08E+00 283.69 1.70 -2.37E+00 1.42E+00 300.07 2.47 4.07E-01 1.62E+00 302.65 2.20 1.18E+00 2.81E+00 330.06 1.40 U-235 -2.10E-02 7.51E-02 3.18E-01 143.76 10.96 4.96E-02 7.57E-01 163.33 5.08 2.90E-02 7.51E-02 185.71 57.20 5.79E-01 3.72E+00 202.11 1.08 -3.74E-01 7.89E-01 205.31 5.01 Am-241 -4.27E-01 4.58E-01 4.58E-01 59.54 35.90

+ 
= Nuclide identified during the nuclide identification Energy line found in the spectrum
= 
= MDA value not calculated Half-life too short to be able to perform the decay correction
= 
? 
= CAUTION: MDA value is inconsistent with Currie MDA at 95% confidence level

9:46:20AM 6/20/2019 Page 1 of 7 L1-12203A-VJGS-002SS 20-Jun-19-10012 Analysis Report for GAMMA SPECTRUM ANALYSIS Sample Description Sample Identification 20-Jun-19-10012 L1-12203A-VJGS-002SS Sample Type Soil Unit Sample Point Sample Size Peak Locate Threshold Peak Locate Range (in channels) Peak Area Range (in channels) Identification Energy Tolerance Sample Taken On Acquisition Started Live Time Real Time Energy Calibration Used Done On Efficiency Calibration Used Done On 1.311E+03 grams 1.000 keV 120 - 8192 120 - 8192 Detector Name 900.4 seconds 900.0 seconds 9/29/2018 6/20/2019 352 6/18/2019 10:10:00AM 6/20/2019 9:31:09AM Dead Time Efficiency Calibration Description 0.04 % Sample Number

77543 Facility Procedure Default 130G_SOIL_1 Administrator Operator 3.00 Geometry 130G_SOIL_1 Fill Height 1311.28 gram Certificate Name Certificate Date Eu155-Na22 1/7/2013 12:00:00PM 120 8192 Peak Analysis To Channel Peak Analysis From Channel Peak Analysis Performed on PEAK ANALYSIS REPORT 6/20/2019 9:46:12AM

~~~pex-Gamma

Page 2 of 7 6/20/2019 9:46:20AM Analysis Report for L1-12203A-VJGS-002SS 20-Jun-19-10012 Peak No. ROI start ROI end (keV) Energy FWHM (keV) Counts Continuum Uncertainty Net Area Area Net Peak Peak Centroid 1 19.62 7.59E+01 316 1.22E+02 305 309.54 77.06 0.44 2 18.88 8.36E+01 752 9.04E+01 737 743.87 185.79 1.07 3 44.55 2.99E+02 974 7.81E+01 M 947 954.93 238.61 1.05 4 15.20 8.90E+01 974 7.45E+01 m 947 967.99 241.88 1.05 5 16.08 1.06E+02 1187 5.48E+01 1174 1180.98 295.19 0.90 6 17.85 7.60E+01 1360 7.40E+01 1343 1353.22 338.29 0.79 7 20.94 2.60E+02 1415 5.72E+01 1399 1407.33 351.83 1.11 8 12.98 9.18E+01 2339 2.63E+01 2325 2331.47 583.04 1.02 9 17.49 1.88E+02 2445 3.51E+01 2427 2436.09 609.21 1.78 10 7.24 2.60E+01 2915 9.02E+00 2901 2907.76 727.16 1.21 11 12.39 5.42E+01 3651 3.18E+01 3635 3642.52 910.87 0.95 12 8.84 4.36E+01 4488 1.14E+01 4473 4480.45 1120.29 0.32 13 25.65 6.13E+02 5854 1.03E+01 5828 5842.71 1460.59 2.14 14 6.58 2.55E+01 7064 6.52E+00 7051 7057.16 1763.77 0.73 Errors quoted at 1.000sigma M = First peak in a multiplet region m = Other peak in a multiplet region F = Fitted singlet No background subtract performed on this spectrum. NUCLIDE IDENTIFICATION REPORT Nuclide Library Used C:\\Canberra\\Apex\\Root\\Default\\Library\\ZION LIB-BNL.NLB IDENTIFIED NUCLIDES Id Yield(%) Activity (pCi/grams) Activity Nuclide Name Confidence (keV) Energy Uncertainty 1.35E+01 8.12E-01 K-40 0.99 10.66 1460.82 1.37E-01 2.10E-02 Tl-208 0.99 85.00 583.19 Bi-212 0.99 1.06 39.86

Page 3 of 7 6/20/2019 9:46:20AM Analysis Report for L1-12203A-VJGS-002SS 20-Jun-19-10012 Id Yield(%) Activity (pCi/grams) Activity Nuclide Name Confidence (keV) Energy Uncertainty 5.71E-01 1.63E-01 6.67 727.33 Bi-212 0.99 1.10 785.37 1.47 1620.50 Pb-212 1.00 0.60 115.18 4.84E-01 8.20E-02 43.60 238.63 3.30 300.09 Pb212-XR 1.00 10.28 74.82 7.25E-01 2.02E-01 17.10 77.11 3.97 87.35 1.46 89.78 5.38E-01 5.96E-02 Bi-214 0.98 45.49 609.32 4.89 768.36 1.26 806.18 3.11 934.06 5.71E-01 1.18E-01 14.92 1120.29 1.63 1155.21 5.83 1238.12 1.43 1280.98 3.99 1377.67 0.79 1385.31 1.33 1401.52 2.39 1407.99 2.13 1509.21 1.05 1661.27 2.88 1729.59 4.50E-01 1.18E-01 15.30 1764.49 2.03 1847.43 1.16 2118.51 8.71E-01 1.64E-01 Pb-214 0.99 7.25 241.99 4.57E-01 7.83E-02 18.42 295.22 6.55E-01 7.44E-02 35.60 351.93 1.06 785.96 Pb214-XR 1.00 5.80 74.82 1.28E+00 3.60E-01 9.70 77.11 2.24 87.35 0.82 89.78 1.45E+00 3.47E-01 Ra-226 0.97 3.64 186.21 Ac-228 0.73 2.42 129.07 3.89 209.25 3.46 270.24 2.95 328.00 5.89E-01 1.46E-01 11.27 338.32 1.92 409.46 4.40 463.00 4.25 794.95 3.58E-01 8.33E-02 25.80 911.20 4.99 964.77 15.80 968.97 3.22 1588.20 U-235 0.99 10.96 143.76 5.08 163.33 9.21E-02 2.21E-02 57.20 185.71 1.08 202.11

Page 4 of 7 6/20/2019 9:46:20AM Analysis Report for L1-12203A-VJGS-002SS 20-Jun-19-10012 Id Yield(%) Activity (pCi/grams) Activity Nuclide Name Confidence (keV) Energy Uncertainty 5.01 205.31 U-235 0.99 = Energy line found in the spectrum. Nuclide confidence index threshold = 0.30 Errors quoted at 1.000sigma Energy Tolerance : 1.000 keV = Energy line not used for Weighted Mean Activity = Manually added nuclide. = Manually edited nuclide. ? INTERFERENCE CORRECTED REPORT Nuclide Name Nuclide (pCi/grams) Wt mean Activity Comments Confidence Wt mean Activity Uncertainty Id 1.35E+01 8.12E-01 K-40 0.991 1.37E-01 2.10E-02 Tl-208 0.996 X Bi-211 0.911 5.71E-01 1.63E-01 Bi-212 0.997 4.84E-01 8.20E-02 Pb-212 1.000 7.25E-01 2.02E-01 ? Pb212-XR 1.000 5.29E-01 4.85E-02 Bi-214 0.988 5.91E-01 5.12E-02 Pb-214 0.999 1.28E+00 3.60E-01 ? Pb214-XR 1.000 1.45E+00 3.47E-01 ? Ra-226 0.972 4.14E-01 7.24E-02 Ac-228 0.738 9.21E-02 2.21E-02 ? U-235 0.999 Errors quoted at 1.000sigma nuclide contains energy lines not used in Weighted Mean Activity = X = nuclide rejected by the interference analysis nuclide is part of an undetermined solution =

? 

Page 5 of 7 6/20/2019 9:46:20AM Analysis Report for L1-12203A-VJGS-002SS 20-Jun-19-10012 UNIDENTIFIED PEAKS Peak Locate Performed on Peak Locate From Channel Peak Locate To Channel 6/20/2019 9:46:12AM 8192 120 Peak No. Energy (keV) Peak Size (CPS) Peak CPS (%) Uncertainty Peak Type Tolerance Nuclide All peaks were identified. Errors quoted at 1.000sigma F = Fitted singlet m = Other peak in a multiplet region M = First peak in a multiplet region

C:\\Canberra\\Apex\\Root\\Default\\Library\\ZION LIB-BNL.NLB Nuclide Library Used NUCLIDE MDA REPORT Line MDA (pCi/grams)

Yield(%) Nuclide Name Nuclide MDA (pCi/grams) Activity (pCi/grams) (keV) Energy An Pk 1.30E-01 7.66E-02 7.66E-02 511.00 100.00 BE-7 -2.17E-02 4.98E-01 4.98E-01 477.60 10.44 + K-40 1.35E+01 5.65E-01 5.65E-01 1460.82 10.66 Mn-54 1.18E-02 6.79E-02 6.79E-02 834.85 99.98 Co-60 9.55E-03 5.77E-02 9.22E-02 1173.23 99.85 -4.36E-02 5.77E-02 1332.49 99.98 Nb-94 3.43E-02 5.10E-02 6.42E-02 702.65 99.81 1.11E-02 5.10E-02 871.09 99.89 Ag-108m 1.03E-01 5.22E-02 2.02E+00 79.13 6.60 7.30E-03 5.22E-02 433.94 90.50 -2.42E-02 1.07E-01 614.28 89.80 -2.84E-03 7.05E-02 722.94 90.80 Sb-125 -9.41E-02 1.57E-01 6.89E-01 176.31 6.84 1.09E+00 3.18E+00 380.45 1.52 -6.51E-02 1.57E-01 427.87 29.60 -9.31E-03 5.19E-01 463.36 10.49 -3.81E-01 2.84E-01 600.60 17.65 5.75E+00 2.11E+00 606.71 4.98 3.14E-01 4.79E-01 635.95 11.22

Page 6 of 7 6/20/2019 9:46:20AM Analysis Report for L1-12203A-VJGS-002SS 20-Jun-19-10012 Line MDA (pCi/grams) Yield(%) Nuclide Name Nuclide MDA (pCi/grams) Activity (pCi/grams) (keV) Energy 7.43E-01 3.14E+00 671.44 1.79 Sb-125 1.57E-01 Ba-133 -6.72E-01 1.20E-01 4.90E+00 79.61 2.65 -5.26E-02 3.29E-01 81.00 32.90 -2.65E-01 6.62E-01 276.40 7.16 1.00E-01 2.61E-01 302.85 18.34 -4.49E-02 1.20E-01 356.01 62.05 -3.38E-02 5.40E-01 383.85 8.94 Cs-134 -2.73E-01 7.30E-02 3.48E+00 475.36 1.48 2.56E-01 6.56E-01 563.25 8.34 1.18E-01 3.63E-01 569.33 15.37 -2.15E-02 9.85E-02 604.72 97.62 2.37E-02 7.30E-02 795.86 85.46 -9.74E-01 5.85E-01 801.95 8.69 3.64E+00 6.98E+00 1038.61 0.99 2.79E+00 4.92E+00 1167.97 1.79 7.95E-01 1.99E+00 1365.19 3.02 Cs-137 -5.81E-03 6.17E-02 6.17E-02 661.66 85.10 Eu-152 5.42E-02 1.90E-01 1.90E-01 121.78 28.67 5.81E-02 7.36E-01 244.70 7.61 2.07E+01 1.40E+01 295.94 0.45 -3.81E-02 1.92E-01 344.28 26.60 -5.67E+00 5.09E+00 367.79 0.86 -5.69E-01 2.19E+00 411.12 2.24 6.75E-01 1.81E+00 443.96 2.83 -6.50E+00 1.10E+01 488.68 0.42 6.20E+00 1.13E+01 563.99 0.49 2.07E+01 1.74E+01 586.26 0.46 -3.34E+00 1.04E+01 678.62 0.47 2.92E+00 5.59E+00 688.67 0.86 1.27E+01 2.06E+01 719.35 0.28 -3.41E-01 4.02E-01 778.90 12.96 -4.80E+00 1.77E+01 810.45 0.32 -9.82E-01 1.18E+00 867.37 4.26 -4.92E+00 1.45E+01 919.33 0.43 8.64E-01 6.14E-01 964.08 14.65 -2.06E-01 6.68E-01 1085.87 10.24 -2.09E+00 4.12E+00 1089.74 1.73 -4.79E-01 5.55E-01 1112.07 13.69 -7.78E-01 5.30E+00 1212.95 1.43 4.38E+00 4.80E+01 1249.94 0.19 -4.44E+00 4.59E+00 1299.14 1.63 3.68E-02 2.91E-01 1408.01 21.07 2.84E+02 5.73E+01 1457.64 0.50 4.10E+00 1.90E+01 1528.10 0.28 Eu-154 -3.07E-02 1.33E-01 1.33E-01 123.07 40.40 -1.23E-01 6.50E-01 247.93 6.89 3.87E-02 1.06E+00 591.76 4.95 -1.06E+00 2.74E+00 692.42 1.78 -1.44E-01 3.11E-01 723.30 20.06 8.30E-01 1.35E+00 756.80 4.52 1.13E-01 4.55E-01 873.18 12.08

Page 7 of 7 6/20/2019 9:46:20AM Analysis Report for L1-12203A-VJGS-002SS 20-Jun-19-10012 Line MDA (pCi/grams) Yield(%) Nuclide Name Nuclide MDA (pCi/grams) Activity (pCi/grams) (keV) Energy -3.09E-01 5.73E-01 996.29 10.48 Eu-154 1.33E-01 1.26E-01 3.28E-01 1004.76 18.01 9.39E-02 2.27E-01 1274.43 34.80 -3.95E+00 3.47E+00 1596.48 1.80 Eu-155 -7.79E+00 2.93E-01 2.61E+01 45.30 1.31 -1.56E+01 2.71E+01 60.01 1.22 -2.34E-01 2.93E-01 86.55 30.70 9.97E-02 2.96E-01 105.31 21.10 + Ra-226 1.45E+00 1.02E+00 1.02E+00 186.21 3.64 Pa-231 4.60E+00 2.08E+00 3.10E+00 27.36 10.30 4.45E-01 2.73E+00 283.69 1.70 2.76E-01 2.08E+00 300.07 2.47 5.07E-01 2.16E+00 302.65 2.20 2.12E+00 3.71E+00 330.06 1.40 + U-235 1.42E-01 6.49E-02 4.76E-01 143.76 10.96 3.93E-01 9.35E-01 163.33 5.08 9.21E-02 6.49E-02 185.71 57.20 -2.57E-01 4.34E+00 202.11 1.08 -3.66E-01 9.63E-01 205.31 5.01 Am-241 -4.86E-02 9.75E-01 9.75E-01 59.54 35.90

+ 
= Nuclide identified during the nuclide identification Energy line found in the spectrum
= 
= MDA value not calculated Half-life too short to be able to perform the decay correction
= 
? 
= CAUTION: MDA value is inconsistent with Currie MDA at 95% confidence level

10:04:42AM 6/20/2019 Page 1 of 7 L1-12203A-VJGS-003SS 20-Jun-19-10013 Analysis Report for GAMMA SPECTRUM ANALYSIS Sample Description Sample Identification 20-Jun-19-10013 L1-12203A-VJGS-003SS Sample Type Soil Unit Sample Point Sample Size Peak Locate Threshold Peak Locate Range (in channels) Peak Area Range (in channels) Identification Energy Tolerance Sample Taken On Acquisition Started Live Time Real Time Energy Calibration Used Done On Efficiency Calibration Used Done On 1.306E+03 grams 1.000 keV 120 - 4096 120 - 4096 Detector Name 900.4 seconds 900.0 seconds 9/29/2018 6/20/2019 324 6/18/2019 10:35:00AM 6/20/2019 9:49:31AM Dead Time Efficiency Calibration Description 0.04 % Sample Number

77544 Facility Procedure Default 130G_SOIL_1 Administrator Operator 3.00 Geometry 130G_SOIL_1 Fill Height 1306.42 gram Certificate Name Certificate Date Eu155-Na22 1/30/2013 12:00:00PM 120 4096 Peak Analysis To Channel Peak Analysis From Channel Peak Analysis Performed on PEAK ANALYSIS REPORT 6/20/2019 10:04:34AM

~~~pex-Gamma

Page 2 of 7 6/20/2019 10:04:42AM Analysis Report for L1-12203A-VJGS-003SS 20-Jun-19-10013 Peak No. ROI start ROI end (keV) Energy FWHM (keV) Counts Continuum Uncertainty Net Area Area Net Peak Peak Centroid 1 22.35 7.95E+01 158 2.07E+02 151 155.00 77.20 0.78 2 18.59 8.65E+01 376 1.22E+02 368 372.59 186.14 1.11 3 24.81 2.33E+02 481 1.74E+02 473 477.57 238.69 1.09 4 17.45 1.29E+02 595 7.76E+01 586 590.54 295.24 1.17 5 13.44 5.91E+01 681 5.59E+01 673 676.66 338.35 1.37 6 18.05 1.77E+02 708 6.60E+01 699 703.97 352.01 1.05 7 14.10 6.64E+01 1027 5.26E+01 1016 1021.88 511.09 1.43 8 13.81 1.07E+02 1171 3.30E+01 1160 1166.03 583.22 1.12 9 14.51 1.44E+02 1223 2.91E+01 1214 1218.27 609.34 1.62 10 11.45 7.45E+01 1827 2.25E+01 1816 1822.02 911.29 1.57 11 8.02 2.45E+01 1941 1.95E+01 1934 1936.92 968.73 1.09 12 9.16 3.10E+01 2247 2.20E+01 2237 2240.62 1120.53 1.75 13 23.64 5.47E+02 2929 3.92E+00 2914 2921.93 1460.94 2.24 Errors quoted at 1.000sigma M = First peak in a multiplet region m = Other peak in a multiplet region F = Fitted singlet No background subtract performed on this spectrum. NUCLIDE IDENTIFICATION REPORT Nuclide Library Used C:\\Canberra\\Apex\\Root\\Default\\Library\\ZION LIB-BNL.NLB IDENTIFIED NUCLIDES Id Yield(%) Activity (pCi/grams) Activity Nuclide Name Confidence (keV) Energy Uncertainty 7.13E-02 1.59E-02 An Pk 0.99 100.00 511.00 1.08E+01 6.62E-01 K-40 0.99 10.66 1460.82 1.44E-01 2.05E-02 Tl-208 1.00 85.00 583.19 Pb-212 0.99 0.60 115.18

Page 3 of 7 6/20/2019 10:04:42AM Analysis Report for L1-12203A-VJGS-003SS 20-Jun-19-10013 Id Yield(%) Activity (pCi/grams) Activity Nuclide Name Confidence (keV) Energy Uncertainty 3.37E-01 4.51E-02 43.60 238.63 Pb-212 0.99 3.30 300.09 Pb212-XR 0.99 10.28 74.82 5.28E-01 1.58E-01 17.10 77.11 3.97 87.35 1.46 89.78 3.72E-01 4.37E-02 Bi-214 0.99 45.49 609.32 4.89 768.36 1.26 806.18 3.11 934.06 3.65E-01 1.09E-01 14.92 1120.29 1.63 1155.21 5.83 1238.12 1.43 1280.98 3.99 1377.67 0.79 1385.31 1.33 1401.52 2.39 1407.99 2.13 1509.21 1.05 1661.27 2.88 1729.59 15.30 1764.49 2.03 1847.43 1.16 2118.51 Pb-214 0.99 7.25 241.99 5.02E-01 7.87E-02 18.42 295.22 4.02E-01 5.22E-02 35.60 351.93 1.06 785.96 Pb214-XR 0.99 5.80 74.82 9.31E-01 2.82E-01 9.70 77.11 2.24 87.35 0.82 89.78 1.33E+00 3.05E-01 Ra-226 0.99 3.64 186.21 Ac-228 0.99 2.42 129.07 3.89 209.25 3.46 270.24 2.95 328.00 4.12E-01 9.97E-02 11.27 338.32 1.92 409.46 4.40 463.00 4.25 794.95 4.44E-01 7.08E-02 25.80 911.20 4.99 964.77 2.48E-01 8.19E-02 15.80 968.97 3.22 1588.20 U-235 0.97 10.96 143.76 5.08 163.33 8.46E-02 1.94E-02 57.20 185.71 1.08 202.11 5.01 205.31

Page 4 of 7 6/20/2019 10:04:42AM Analysis Report for L1-12203A-VJGS-003SS 20-Jun-19-10013 = Energy line found in the spectrum. Nuclide confidence index threshold = 0.30 Errors quoted at 1.000sigma Energy Tolerance : 1.000 keV = Energy line not used for Weighted Mean Activity = Manually added nuclide. = Manually edited nuclide. ? INTERFERENCE CORRECTED REPORT Nuclide Name Nuclide (pCi/grams) Wt mean Activity Comments Confidence Wt mean Activity Uncertainty Id 7.13E-02 1.59E-02 An Pk 0.999 1.08E+01 6.62E-01 K-40 0.998 1.44E-01 2.05E-02 Tl-208 1.000 X Bi-211 0.868 3.37E-01 4.51E-02 Pb-212 0.999 5.28E-01 1.58E-01 ? Pb212-XR 0.999 3.71E-01 4.05E-02 Bi-214 0.999 4.33E-01 4.35E-02 Pb-214 0.999 9.31E-01 2.82E-01 ? Pb214-XR 0.999 1.33E+00 3.05E-01 ? Ra-226 0.999 3.72E-01 4.72E-02 Ac-228 0.998 8.46E-02 1.94E-02 ? U-235 0.979 Errors quoted at 1.000sigma nuclide contains energy lines not used in Weighted Mean Activity = X = nuclide rejected by the interference analysis nuclide is part of an undetermined solution =

? 

Page 5 of 7 6/20/2019 10:04:42AM Analysis Report for L1-12203A-VJGS-003SS 20-Jun-19-10013 UNIDENTIFIED PEAKS Peak Locate Performed on Peak Locate From Channel Peak Locate To Channel 6/20/2019 10:04:34AM 4096 120 Peak No. Energy (keV) Peak Size (CPS) Peak CPS (%) Uncertainty Peak Type Tolerance Nuclide All peaks were identified. Errors quoted at 1.000sigma F = Fitted singlet m = Other peak in a multiplet region M = First peak in a multiplet region

C:\\Canberra\\Apex\\Root\\Default\\Library\\ZION LIB-BNL.NLB Nuclide Library Used NUCLIDE MDA REPORT Line MDA (pCi/grams)

Yield(%) Nuclide Name Nuclide MDA (pCi/grams) Activity (pCi/grams) (keV) Energy + An Pk 7.13E-02 4.50E-02 4.50E-02 511.00 100.00 BE-7 -1.09E-01 3.94E-01 3.94E-01 477.60 10.44 + K-40 1.08E+01 2.86E-01 2.86E-01 1460.82 10.66 Mn-54 -9.43E-04 4.66E-02 4.66E-02 834.85 99.98 Co-60 9.15E-02 5.65E-02 8.40E-02 1173.23 99.85 -2.90E-02 5.65E-02 1332.49 99.98 Nb-94 -2.97E-02 4.35E-02 4.35E-02 702.65 99.81 -7.24E-03 4.41E-02 871.09 99.89 Ag-108m -1.41E-01 4.48E-02 1.37E+00 79.13 6.60 -1.49E-04 4.48E-02 433.94 90.50 -5.50E-02 7.30E-02 614.28 89.80 2.17E-02 5.85E-02 722.94 90.80 Sb-125 2.22E-01 1.45E-01 5.99E-01 176.31 6.84 -1.30E+00 2.15E+00 380.45 1.52 4.34E-02 1.45E-01 427.87 29.60 3.35E-01 4.60E-01 463.36 10.49 -4.20E-02 2.17E-01 600.60 17.65 -1.15E+00 1.64E+00 606.71 4.98 6.63E-02 3.67E-01 635.95 11.22

Page 6 of 7 6/20/2019 10:04:42AM Analysis Report for L1-12203A-VJGS-003SS 20-Jun-19-10013 Line MDA (pCi/grams) Yield(%) Nuclide Name Nuclide MDA (pCi/grams) Activity (pCi/grams) (keV) Energy -2.40E+00 2.46E+00 671.44 1.79 Sb-125 1.45E-01 Ba-133 -9.07E-01 9.30E-02 3.19E+00 79.61 2.65 -1.72E-01 2.07E-01 81.00 32.90 -2.27E-01 5.28E-01 276.40 7.16 1.40E-01 2.05E-01 302.85 18.34 -5.89E-02 9.30E-02 356.01 62.05 -1.54E-01 3.83E-01 383.85 8.94 Cs-134 3.79E-01 6.43E-02 2.79E+00 475.36 1.48 2.52E-01 4.84E-01 563.25 8.34 1.12E-01 2.62E-01 569.33 15.37 -7.94E-02 6.66E-02 604.72 97.62 5.47E-02 6.43E-02 795.86 85.46 -5.87E-01 5.02E-01 801.95 8.69 -1.89E+00 5.29E+00 1038.61 0.99 -1.02E+00 4.34E+00 1167.97 1.79 -2.99E-02 1.20E+00 1365.19 3.02 Cs-137 4.84E-02 6.20E-02 6.20E-02 661.66 85.10 Eu-152 -3.87E-02 1.26E-01 1.26E-01 121.78 28.67 -2.69E-01 5.51E-01 244.70 7.61 1.47E+01 1.20E+01 295.94 0.45 -1.17E-01 1.41E-01 344.28 26.60 1.06E+00 4.49E+00 367.79 0.86 1.44E-01 1.78E+00 411.12 2.24 5.49E-01 1.34E+00 443.96 2.83 2.77E+00 1.08E+01 488.68 0.42 2.00E+00 7.98E+00 563.99 0.49 -4.07E+00 1.56E+01 586.26 0.46 1.79E+00 1.12E+01 678.62 0.47 -1.80E+00 5.31E+00 688.67 0.86 -1.93E+00 1.67E+01 719.35 0.28 -2.46E-01 2.65E-01 778.90 12.96 -4.75E+00 1.40E+01 810.45 0.32 -3.34E-01 1.00E+00 867.37 4.26 -2.89E+00 1.32E+01 919.33 0.43 -2.90E-01 4.84E-01 964.08 14.65 -3.94E-01 5.53E-01 1085.87 10.24 1.14E+00 3.54E+00 1089.74 1.73 1.19E-02 4.44E-01 1112.07 13.69 -6.75E-01 4.99E+00 1212.95 1.43 -9.85E+00 2.95E+01 1249.94 0.19 6.30E-01 3.77E+00 1299.14 1.63 9.86E-02 2.52E-01 1408.01 21.07 -4.98E+00 4.85E+01 1457.64 0.50 -3.38E+00 1.27E+01 1528.10 0.28 Eu-154 -6.16E-02 8.83E-02 8.83E-02 123.07 40.40 -1.31E-01 5.22E-01 247.93 6.89 8.95E-03 8.00E-01 591.76 4.95 2.14E-01 2.60E+00 692.42 1.78 1.65E-01 2.73E-01 723.30 20.06 5.59E-02 1.01E+00 756.80 4.52 -6.74E-02 3.65E-01 873.18 12.08

Page 7 of 7 6/20/2019 10:04:42AM Analysis Report for L1-12203A-VJGS-003SS 20-Jun-19-10013 Line MDA (pCi/grams) Yield(%) Nuclide Name Nuclide MDA (pCi/grams) Activity (pCi/grams) (keV) Energy -1.44E-01 5.05E-01 996.29 10.48 Eu-154 8.83E-02 2.19E-01 3.12E-01 1004.76 18.01 1.30E-01 1.98E-01 1274.43 34.80 -1.35E+00 2.06E+00 1596.48 1.80 Eu-155 -1.99E+00 2.08E-01 1.28E+01 45.30 1.31 6.01E-01 1.52E+01 60.01 1.22 2.56E-02 2.10E-01 86.55 30.70 1.56E-02 2.08E-01 105.31 21.10 + Ra-226 1.33E+00 8.84E-01 8.84E-01 186.21 3.64 Pa-231 2.75E-01 1.26E+00 1.26E+00 27.36 10.30 -1.03E+00 2.29E+00 283.69 1.70 3.43E-02 1.54E+00 300.07 2.47 1.17E+00 1.70E+00 302.65 2.20 1.30E+00 2.83E+00 330.06 1.40 + U-235 5.44E-02 5.62E-02 3.26E-01 143.76 10.96 -3.64E-01 7.82E-01 163.33 5.08 8.46E-02 5.62E-02 185.71 57.20 -1.42E+00 3.41E+00 202.11 1.08 -4.96E-01 7.80E-01 205.31 5.01 Am-241 -1.81E-02 5.24E-01 5.24E-01 59.54 35.90

+ 
= Nuclide identified during the nuclide identification Energy line found in the spectrum
= 
= MDA value not calculated Half-life too short to be able to perform the decay correction
= 
? 
= CAUTION: MDA value is inconsistent with Currie MDA at 95% confidence level

10:04:49AM 6/20/2019 Page 1 of 7 L1-12203A-VJGS-004SS 20-Jun-19-10014 Analysis Report for GAMMA SPECTRUM ANALYSIS Sample Description Sample Identification 20-Jun-19-10014 L1-12203A-VJGS-004SS Sample Type Soil Unit Sample Point Sample Size Peak Locate Threshold Peak Locate Range (in channels) Peak Area Range (in channels) Identification Energy Tolerance Sample Taken On Acquisition Started Live Time Real Time Energy Calibration Used Done On Efficiency Calibration Used Done On 1.290E+03 grams 1.000 keV 120 - 8192 120 - 8192 Detector Name 900.4 seconds 900.0 seconds 9/29/2018 6/20/2019 352 6/18/2019 1:00:00PM 6/20/2019 9:49:39AM Dead Time Efficiency Calibration Description 0.04 % Sample Number

77545 Facility Procedure Default 130G_SOIL_1 Administrator Operator 3.00 Geometry 130G_SOIL_1 Fill Height 1290.49 gram Certificate Name Certificate Date Eu155-Na22 1/7/2013 12:00:00PM 120 8192 Peak Analysis To Channel Peak Analysis From Channel Peak Analysis Performed on PEAK ANALYSIS REPORT 6/20/2019 10:04:42AM

~~~pex-Gamma

Page 2 of 7 6/20/2019 10:04:49AM Analysis Report for L1-12203A-VJGS-004SS 20-Jun-19-10014 Peak No. ROI start ROI end (keV) Energy FWHM (keV) Counts Continuum Uncertainty Net Area Area Net Peak Peak Centroid 1 18.73 5.54E+01 317 1.05E+02 306 309.62 77.08 0.70 2 22.24 1.08E+02 753 1.14E+02 735 744.67 185.99 1.23 3 18.73 3.24E+02 973 8.38E+01 M 948 955.00 238.63 1.10 4 10.54 8.53E+01 973 6.10E+01 m 948 967.43 241.74 1.11 5 16.69 1.55E+02 1187 4.30E+01 1173 1180.89 295.17 1.05 6 14.61 6.93E+01 1362 4.97E+01 1348 1353.68 338.41 0.36 7 19.78 2.35E+02 1417 4.70E+01 1399 1407.40 351.85 0.91 8 13.64 9.49E+01 2339 3.01E+01 2324 2331.38 583.01 1.18 9 15.03 1.80E+02 2445 1.46E+01 2429 2436.38 609.28 1.66 10 11.10 1.03E+02 3654 5.50E+00 3633 3643.44 911.10 2.00 11 10.34 4.13E+01 3882 2.17E+01 3867 3873.57 968.62 0.78 12 7.64 1.90E+01 4958 1.40E+01 4945 4951.72 1238.04 0.25 13 25.59 6.37E+02 5854 3.71E+00 5827 5842.35 1460.49 1.73 Errors quoted at 1.000sigma M = First peak in a multiplet region m = Other peak in a multiplet region F = Fitted singlet No background subtract performed on this spectrum. NUCLIDE IDENTIFICATION REPORT Nuclide Library Used C:\\Canberra\\Apex\\Root\\Default\\Library\\ZION LIB-BNL.NLB IDENTIFIED NUCLIDES Id Yield(%) Activity (pCi/grams) Activity Nuclide Name Confidence (keV) Energy Uncertainty 1.41E+01 8.33E-01 K-40 0.98 10.66 1460.82 1.42E-01 2.21E-02 Tl-208 0.99 85.00 583.19 Pb-212 1.00 0.60 115.18 5.26E-01 5.23E-02 43.60 238.63

Page 3 of 7 6/20/2019 10:04:49AM Analysis Report for L1-12203A-VJGS-004SS 20-Jun-19-10014 Id Yield(%) Activity (pCi/grams) Activity Nuclide Name Confidence (keV) Energy Uncertainty 3.30 300.09 Pb-212 1.00 Pb212-XR 1.00 10.28 74.82 5.30E-01 1.87E-01 17.10 77.11 3.97 87.35 1.46 89.78 5.19E-01 5.33E-02 Bi-214 1.00 45.49 609.32 4.89 768.36 1.26 806.18 3.11 934.06 14.92 1120.29 1.63 1155.21 6.82E-01 2.76E-01 5.83 1238.12 1.43 1280.98 3.99 1377.67 0.79 1385.31 1.33 1401.52 2.39 1407.99 2.13 1509.21 1.05 1661.27 2.88 1729.59 15.30 1764.49 2.03 1847.43 1.16 2118.51 8.38E-01 1.23E-01 Pb-214 0.99 7.25 241.99 6.70E-01 8.99E-02 18.42 295.22 5.95E-01 6.91E-02 35.60 351.93 1.06 785.96 Pb214-XR 1.00 5.80 74.82 9.34E-01 3.33E-01 9.70 77.11 2.24 87.35 0.82 89.78 1.87E+00 4.14E-01 Ra-226 0.99 3.64 186.21 Ac-228 0.99 2.42 129.07 3.89 209.25 3.46 270.24 2.95 328.00 5.39E-01 1.22E-01 11.27 338.32 1.92 409.46 4.40 463.00 4.25 794.95 6.80E-01 7.93E-02 25.80 911.20 4.99 964.77 4.67E-01 1.19E-01 15.80 968.97 3.22 1588.20 U-235 0.99 10.96 143.76 5.08 163.33 1.19E-01 2.63E-02 57.20 185.71 1.08 202.11 5.01 205.31

Page 4 of 7 6/20/2019 10:04:49AM Analysis Report for L1-12203A-VJGS-004SS 20-Jun-19-10014 = Energy line found in the spectrum. Nuclide confidence index threshold = 0.30 Errors quoted at 1.000sigma Energy Tolerance : 1.000 keV = Energy line not used for Weighted Mean Activity = Manually added nuclide. = Manually edited nuclide. ? INTERFERENCE CORRECTED REPORT Nuclide Name Nuclide (pCi/grams) Wt mean Activity Comments Confidence Wt mean Activity Uncertainty Id 1.41E+01 8.33E-01 K-40 0.983 1.42E-01 2.21E-02 Tl-208 0.995 X Bi-211 0.907 5.26E-01 5.23E-02 Pb-212 1.000 5.30E-01 1.87E-01 ? Pb212-XR 1.000 5.25E-01 5.24E-02 Bi-214 1.000 6.58E-01 5.01E-02 Pb-214 0.998 9.34E-01 3.33E-01 ? Pb214-XR 1.000 1.87E+00 4.14E-01 ? Ra-226 0.992 5.97E-01 5.80E-02 Ac-228 0.996 1.19E-01 2.63E-02 ? U-235 0.992 Errors quoted at 1.000sigma nuclide contains energy lines not used in Weighted Mean Activity = X = nuclide rejected by the interference analysis nuclide is part of an undetermined solution =

? 

Page 5 of 7 6/20/2019 10:04:49AM Analysis Report for L1-12203A-VJGS-004SS 20-Jun-19-10014 UNIDENTIFIED PEAKS Peak Locate Performed on Peak Locate From Channel Peak Locate To Channel 6/20/2019 10:04:42AM 8192 120 Peak No. Energy (keV) Peak Size (CPS) Peak CPS (%) Uncertainty Peak Type Tolerance Nuclide All peaks were identified. Errors quoted at 1.000sigma F = Fitted singlet m = Other peak in a multiplet region M = First peak in a multiplet region

C:\\Canberra\\Apex\\Root\\Default\\Library\\ZION LIB-BNL.NLB Nuclide Library Used NUCLIDE MDA REPORT Line MDA (pCi/grams)

Yield(%) Nuclide Name Nuclide MDA (pCi/grams) Activity (pCi/grams) (keV) Energy An Pk 5.63E-02 6.12E-02 6.12E-02 511.00 100.00 BE-7 3.65E-01 4.50E-01 4.50E-01 477.60 10.44 + K-40 1.41E+01 3.77E-01 3.77E-01 1460.82 10.66 Mn-54 1.67E-02 6.02E-02 6.02E-02 834.85 99.98 Co-60 -1.18E-01 6.79E-02 7.65E-02 1173.23 99.85 -1.93E-02 6.79E-02 1332.49 99.98 Nb-94 7.33E-03 5.73E-02 5.73E-02 702.65 99.81 -1.66E-03 6.00E-02 871.09 99.89 Ag-108m -4.58E-01 5.05E-02 1.86E+00 79.13 6.60 -2.84E-02 5.05E-02 433.94 90.50 3.19E-02 1.07E-01 614.28 89.80 3.23E-02 6.71E-02 722.94 90.80 Sb-125 -7.54E-02 1.59E-01 6.54E-01 176.31 6.84 -1.00E+00 2.74E+00 380.45 1.52 6.02E-02 1.59E-01 427.87 29.60 3.07E-01 4.90E-01 463.36 10.49 1.60E-01 3.23E-01 600.60 17.65 3.40E+00 2.00E+00 606.71 4.98 1.59E-01 4.66E-01 635.95 11.22

Page 6 of 7 6/20/2019 10:04:49AM Analysis Report for L1-12203A-VJGS-004SS 20-Jun-19-10014 Line MDA (pCi/grams) Yield(%) Nuclide Name Nuclide MDA (pCi/grams) Activity (pCi/grams) (keV) Energy -2.37E+00 2.98E+00 671.44 1.79 Sb-125 1.59E-01 Ba-133 -7.27E-01 1.16E-01 4.47E+00 79.61 2.65 -2.96E-02 3.12E-01 81.00 32.90 3.26E-01 6.96E-01 276.40 7.16 8.96E-02 2.70E-01 302.85 18.34 -7.73E-03 1.16E-01 356.01 62.05 6.75E-02 4.91E-01 383.85 8.94 Cs-134 -1.20E+00 7.77E-02 2.84E+00 475.36 1.48 -9.96E-02 5.59E-01 563.25 8.34 2.56E-01 3.48E-01 569.33 15.37 -4.97E-02 9.61E-02 604.72 97.62 5.15E-02 7.77E-02 795.86 85.46 5.11E-02 7.69E-01 801.95 8.69 7.56E-01 7.26E+00 1038.61 0.99 2.39E+00 4.51E+00 1167.97 1.79 1.21E+00 1.92E+00 1365.19 3.02 Cs-137 -1.26E-02 6.81E-02 6.81E-02 661.66 85.10 Eu-152 3.75E-03 1.81E-01 1.89E-01 121.78 28.67 -4.98E-02 7.29E-01 244.70 7.61 2.33E+01 1.46E+01 295.94 0.45 -2.77E-02 1.81E-01 344.28 26.60 -2.99E-01 4.97E+00 367.79 0.86 1.66E-01 2.18E+00 411.12 2.24 -4.73E-01 1.70E+00 443.96 2.83 6.07E+00 1.25E+01 488.68 0.42 1.55E-01 9.74E+00 563.99 0.49 3.52E+00 1.78E+01 586.26 0.46 -3.43E+00 1.10E+01 678.62 0.47 -2.49E+00 5.86E+00 688.67 0.86 -1.30E+00 1.80E+01 719.35 0.28 -2.12E-01 4.50E-01 778.90 12.96 -1.85E+00 1.90E+01 810.45 0.32 -2.09E+00 1.44E+00 867.37 4.26 1.08E+00 1.35E+01 919.33 0.43 7.04E-02 6.57E-01 964.08 14.65 3.84E-01 7.10E-01 1085.87 10.24 -1.47E+00 4.06E+00 1089.74 1.73 -4.18E-01 5.75E-01 1112.07 13.69 -5.09E+00 5.53E+00 1212.95 1.43 1.12E+00 4.33E+01 1249.94 0.19 2.18E+00 4.32E+00 1299.14 1.63 6.22E-02 2.97E-01 1408.01 21.07 2.96E+02 5.86E+01 1457.64 0.50 3.24E+00 2.06E+01 1528.10 0.28 Eu-154 2.04E-02 1.32E-01 1.32E-01 123.07 40.40 1.55E-01 6.73E-01 247.93 6.89 -3.52E-01 1.05E+00 591.76 4.95 6.02E-01 3.01E+00 692.42 1.78 2.25E-01 3.08E-01 723.30 20.06 -1.19E+00 1.20E+00 756.80 4.52 -1.42E-01 4.77E-01 873.18 12.08

Page 7 of 7 6/20/2019 10:04:49AM Analysis Report for L1-12203A-VJGS-004SS 20-Jun-19-10014 Line MDA (pCi/grams) Yield(%) Nuclide Name Nuclide MDA (pCi/grams) Activity (pCi/grams) (keV) Energy 1.98E-02 6.08E-01 996.29 10.48 Eu-154 1.32E-01 1.79E-01 3.67E-01 1004.76 18.01 1.58E-02 2.30E-01 1274.43 34.80 8.95E-01 3.01E+00 1596.48 1.80 Eu-155 -6.19E+00 2.92E-01 2.61E+01 45.30 1.31 -1.03E+01 2.86E+01 60.01 1.22 6.45E-02 3.12E-01 86.55 30.70 -6.23E-02 2.92E-01 105.31 21.10 + Ra-226 1.87E+00 1.21E+00 1.21E+00 186.21 3.64 Pa-231 5.24E+00 2.08E+00 3.21E+00 27.36 10.30 1.94E+00 2.81E+00 283.69 1.70 -3.10E+00 2.08E+00 300.07 2.47 1.06E+00 2.25E+00 302.65 2.20 -2.33E+00 3.58E+00 330.06 1.40 + U-235 -1.09E-01 7.67E-02 4.30E-01 143.76 10.96 -4.31E-01 9.25E-01 163.33 5.08 1.19E-01 7.67E-02 185.71 57.20 2.38E+00 4.42E+00 202.11 1.08 -9.27E-01 9.14E-01 205.31 5.01 Am-241 -1.09E+00 9.77E-01 9.77E-01 59.54 35.90

+ 
= Nuclide identified during the nuclide identification Energy line found in the spectrum
= 
= MDA value not calculated Half-life too short to be able to perform the decay correction
= 
? 
= CAUTION: MDA value is inconsistent with Currie MDA at 95% confidence level

10:21:52AM 6/20/2019 Page 1 of 7 L1-12203A-VJGS-005SS 20-Jun-19-10015 Analysis Report for GAMMA SPECTRUM ANALYSIS Sample Description Sample Identification 20-Jun-19-10015 L1-12203A-VJGS-005SS Sample Type Soil Unit Sample Point Sample Size Peak Locate Threshold Peak Locate Range (in channels) Peak Area Range (in channels) Identification Energy Tolerance Sample Taken On Acquisition Started Live Time Real Time Energy Calibration Used Done On Efficiency Calibration Used Done On 1.324E+03 grams 1.000 keV 120 - 4096 120 - 4096 Detector Name 900.4 seconds 900.0 seconds 9/29/2018 6/20/2019 324 6/18/2019 1:11:00PM 6/20/2019 10:06:40AM Dead Time Efficiency Calibration Description 0.04 % Sample Number

77546 Facility Procedure Default 130G_SOIL_1 Administrator Operator 3.00 Geometry 130G_SOIL_1 Fill Height 1324.06 gram Certificate Name Certificate Date Eu155-Na22 1/30/2013 12:00:00PM 120 4096 Peak Analysis To Channel Peak Analysis From Channel Peak Analysis Performed on PEAK ANALYSIS REPORT 6/20/2019 10:21:42AM

~~~pex-Gamma

Page 2 of 7 6/20/2019 10:21:52AM Analysis Report for L1-12203A-VJGS-005SS 20-Jun-19-10015 Peak No. ROI start ROI end (keV) Energy FWHM (keV) Counts Continuum Uncertainty Net Area Area Net Peak Peak Centroid 1 19.50 7.73E+01 376 1.41E+02 368 372.77 186.23 1.05 2 24.10 1.83E+02 481 1.80E+02 473 477.58 238.70 1.07 3 16.70 9.41E+01 595 8.19E+01 586 590.68 295.31 1.35 4 14.11 4.61E+01 681 6.69E+01 672 676.57 338.30 1.23 5 18.18 2.17E+02 708 5.02E+01 699 703.97 352.01 1.15 6 12.45 9.09E+01 1170 3.01E+01 1162 1166.08 583.24 1.58 7 14.45 1.37E+02 1223 3.00E+01 1213 1218.20 609.31 1.21 8 8.06 1.31E+01 1458 2.39E+01 1450 1455.13 727.82 0.85 9 12.01 6.66E+01 1827 2.94E+01 1815 1822.37 911.46 1.83 10 8.71 3.10E+01 2243 1.90E+01 2234 2240.02 1120.23 1.53 11 24.12 5.73E+02 2929 3.71E+00 2917 2921.88 1460.91 1.75 Errors quoted at 1.000sigma M = First peak in a multiplet region m = Other peak in a multiplet region F = Fitted singlet No background subtract performed on this spectrum. NUCLIDE IDENTIFICATION REPORT Nuclide Library Used C:\\Canberra\\Apex\\Root\\Default\\Library\\ZION LIB-BNL.NLB IDENTIFIED NUCLIDES Id Yield(%) Activity (pCi/grams) Activity Nuclide Name Confidence (keV) Energy Uncertainty 1.13E+01 6.82E-01 K-40 0.99 10.66 1460.82 1.22E-01 1.82E-02 Tl-208 1.00 85.00 583.19 Bi-212 0.97 1.06 39.86 2.58E-01 1.60E-01 6.67 727.33 1.10 785.37 1.47 1620.50

Page 3 of 7 6/20/2019 10:21:52AM Analysis Report for L1-12203A-VJGS-005SS 20-Jun-19-10015 Id Yield(%) Activity (pCi/grams) Activity Nuclide Name Confidence (keV) Energy Uncertainty Pb-212 0.99 0.60 115.18 2.64E-01 4.09E-02 43.60 238.63 3.30 300.09 3.53E-01 4.28E-02 Bi-214 1.00 45.49 609.32 4.89 768.36 1.26 806.18 3.11 934.06 3.64E-01 1.03E-01 14.92 1120.29 1.63 1155.21 5.83 1238.12 1.43 1280.98 3.99 1377.67 0.79 1385.31 1.33 1401.52 2.39 1407.99 2.13 1509.21 1.05 1661.27 2.88 1729.59 15.30 1764.49 2.03 1847.43 1.16 2118.51 Pb-214 0.99 7.25 241.99 3.64E-01 7.08E-02 18.42 295.22 4.91E-01 5.69E-02 35.60 351.93 1.06 785.96 1.18E+00 3.14E-01 Ra-226 1.00 3.64 186.21 Ac-228 0.99 2.42 129.07 3.89 209.25 3.46 270.24 2.95 328.00 3.20E-01 1.02E-01 11.27 338.32 1.92 409.46 4.40 463.00 4.25 794.95 3.95E-01 7.32E-02 25.80 911.20 4.99 964.77 15.80 968.97 3.22 1588.20 U-235 0.97 10.96 143.76 5.08 163.33 7.53E-02 2.00E-02 57.20 185.71 1.08 202.11 5.01 205.31 = Energy line found in the spectrum. Nuclide confidence index threshold = 0.30 Errors quoted at 1.000sigma Energy Tolerance : 1.000 keV = Energy line not used for Weighted Mean Activity = Manually added nuclide. = Manually edited nuclide. ?

Page 4 of 7 6/20/2019 10:21:52AM Analysis Report for L1-12203A-VJGS-005SS 20-Jun-19-10015 INTERFERENCE CORRECTED REPORT Nuclide Name Nuclide (pCi/grams) Wt mean Activity Comments Confidence Wt mean Activity Uncertainty Id 1.13E+01 6.82E-01 K-40 0.999 1.22E-01 1.82E-02 Tl-208 1.000 X Bi-211 0.868 2.58E-01 1.60E-01 Bi-212 0.975 2.64E-01 4.09E-02 Pb-212 0.999 3.54E-01 3.95E-02 Bi-214 1.000 4.41E-01 4.44E-02 Pb-214 0.999 1.18E+00 3.14E-01 ? Ra-226 1.000 3.70E-01 5.94E-02 Ac-228 0.997 7.53E-02 2.00E-02 ? U-235 0.970 Errors quoted at 1.000sigma nuclide contains energy lines not used in Weighted Mean Activity = X = nuclide rejected by the interference analysis nuclide is part of an undetermined solution =

? 

Page 5 of 7 6/20/2019 10:21:52AM Analysis Report for L1-12203A-VJGS-005SS 20-Jun-19-10015 UNIDENTIFIED PEAKS Peak Locate Performed on Peak Locate From Channel Peak Locate To Channel 6/20/2019 10:21:42AM 4096 120 Peak No. Energy (keV) Peak Size (CPS) Peak CPS (%) Uncertainty Peak Type Tolerance Nuclide All peaks were identified. Errors quoted at 1.000sigma F = Fitted singlet m = Other peak in a multiplet region M = First peak in a multiplet region

C:\\Canberra\\Apex\\Root\\Default\\Library\\ZION LIB-BNL.NLB Nuclide Library Used NUCLIDE MDA REPORT Line MDA (pCi/grams)

Yield(%) Nuclide Name Nuclide MDA (pCi/grams) Activity (pCi/grams) (keV) Energy An Pk 9.72E-02 6.16E-02 6.16E-02 511.00 100.00 BE-7 2.46E-01 4.14E-01 4.14E-01 477.60 10.44 + K-40 1.13E+01 2.50E-01 2.50E-01 1460.82 10.66 Mn-54 3.68E-03 5.18E-02 5.18E-02 834.85 99.98 Co-60 6.96E-03 5.17E-02 7.05E-02 1173.23 99.85 2.29E-02 5.17E-02 1332.49 99.98 Nb-94 1.81E-02 4.83E-02 4.83E-02 702.65 99.81 5.61E-04 5.09E-02 871.09 99.89 Ag-108m 9.57E-01 4.12E-02 1.42E+00 79.13 6.60 3.36E-03 4.12E-02 433.94 90.50 -6.78E-02 6.76E-02 614.28 89.80 -2.38E-03 5.02E-02 722.94 90.80 Sb-125 2.24E-01 1.27E-01 6.23E-01 176.31 6.84 8.19E-01 2.63E+00 380.45 1.52 -4.48E-02 1.27E-01 427.87 29.60 2.14E-01 4.36E-01 463.36 10.49 4.99E-02 2.67E-01 600.60 17.65 2.35E-02 1.64E+00 606.71 4.98 -2.25E-01 3.61E-01 635.95 11.22

Page 6 of 7 6/20/2019 10:21:52AM Analysis Report for L1-12203A-VJGS-005SS 20-Jun-19-10015 Line MDA (pCi/grams) Yield(%) Nuclide Name Nuclide MDA (pCi/grams) Activity (pCi/grams) (keV) Energy -1.05E-01 2.47E+00 671.44 1.79 Sb-125 1.27E-01 Ba-133 5.76E-01 9.83E-02 3.26E+00 79.61 2.65 -3.84E-01 2.08E-01 81.00 32.90 1.30E-01 5.83E-01 276.40 7.16 1.40E-01 2.18E-01 302.85 18.34 -8.71E-02 9.83E-02 356.01 62.05 1.12E-01 4.52E-01 383.85 8.94 Cs-134 -2.29E+00 5.97E-02 2.52E+00 475.36 1.48 -5.54E-02 4.91E-01 563.25 8.34 9.92E-02 2.78E-01 569.33 15.37 -1.95E-02 6.98E-02 604.72 97.62 2.94E-02 5.97E-02 795.86 85.46 -2.29E-01 5.50E-01 801.95 8.69 1.79E-01 5.54E+00 1038.61 0.99 1.24E+00 4.08E+00 1167.97 1.79 4.49E-01 1.46E+00 1365.19 3.02 Cs-137 2.38E-02 6.00E-02 6.00E-02 661.66 85.10 Eu-152 5.21E-02 1.39E-01 1.39E-01 121.78 28.67 -1.64E-02 6.05E-01 244.70 7.61 9.16E+00 1.13E+01 295.94 0.45 1.68E-02 1.46E-01 344.28 26.60 2.15E+00 4.47E+00 367.79 0.86 5.28E-01 1.83E+00 411.12 2.24 -2.83E-01 1.33E+00 443.96 2.83 1.55E+00 9.63E+00 488.68 0.42 -5.76E-01 8.49E+00 563.99 0.49 -1.09E+01 1.56E+01 586.26 0.46 7.81E-01 9.16E+00 678.62 0.47 -1.33E+00 5.34E+00 688.67 0.86 -7.64E+00 1.39E+01 719.35 0.28 -1.19E-01 3.65E-01 778.90 12.96 6.20E+00 1.41E+01 810.45 0.32 -6.31E-01 1.14E+00 867.37 4.26 -1.45E+01 1.12E+01 919.33 0.43 -2.73E-01 4.72E-01 964.08 14.65 -1.76E-02 5.69E-01 1085.87 10.24 -1.48E+00 3.26E+00 1089.74 1.73 3.82E-02 4.64E-01 1112.07 13.69 -5.78E-01 4.88E+00 1212.95 1.43 6.92E+00 3.48E+01 1249.94 0.19 1.47E-01 3.29E+00 1299.14 1.63 1.40E-01 2.69E-01 1408.01 21.07 -6.74E+01 4.94E+01 1457.64 0.50 4.21E+00 1.33E+01 1528.10 0.28 Eu-154 1.24E-02 9.40E-02 9.40E-02 123.07 40.40 1.47E-01 5.63E-01 247.93 6.89 1.75E-01 9.37E-01 591.76 4.95 -6.54E-01 2.64E+00 692.42 1.78 5.54E-03 2.50E-01 723.30 20.06 1.59E-01 1.03E+00 756.80 4.52 1.34E-01 4.13E-01 873.18 12.08

Page 7 of 7 6/20/2019 10:21:52AM Analysis Report for L1-12203A-VJGS-005SS 20-Jun-19-10015 Line MDA (pCi/grams) Yield(%) Nuclide Name Nuclide MDA (pCi/grams) Activity (pCi/grams) (keV) Energy 1.46E-01 5.64E-01 996.29 10.48 Eu-154 9.40E-02 -1.53E-01 3.11E-01 1004.76 18.01 7.96E-03 1.81E-01 1274.43 34.80 -2.39E+00 2.43E+00 1596.48 1.80 Eu-155 -6.09E-01 2.14E-01 1.30E+01 45.30 1.31 -2.10E+00 1.47E+01 60.01 1.22 1.42E-01 2.16E-01 86.55 30.70 -4.07E-02 2.14E-01 105.31 21.10 + Ra-226 1.18E+00 9.48E-01 9.48E-01 186.21 3.64 Pa-231 1.05E+00 1.43E+00 1.43E+00 27.36 10.30 -1.13E+00 2.08E+00 283.69 1.70 -2.87E-01 1.58E+00 300.07 2.47 1.17E+00 1.82E+00 302.65 2.20 1.00E+00 2.93E+00 330.06 1.40 + U-235 -1.09E-01 6.04E-02 3.34E-01 143.76 10.96 1.18E-01 8.02E-01 163.33 5.08 7.53E-02 6.04E-02 185.71 57.20 -2.29E-01 3.45E+00 202.11 1.08 -7.62E-01 7.22E-01 205.31 5.01 Am-241 -6.90E-04 5.18E-01 5.18E-01 59.54 35.90

+ 
= Nuclide identified during the nuclide identification Energy line found in the spectrum
= 
= MDA value not calculated Half-life too short to be able to perform the decay correction
= 
? 
= CAUTION: MDA value is inconsistent with Currie MDA at 95% confidence level

10:22:00AM 6/20/2019 Page 1 of 7 L1-12203A-VJGS-006SS 20-Jun-19-10016 Analysis Report for GAMMA SPECTRUM ANALYSIS Sample Description Sample Identification 20-Jun-19-10016 L1-12203A-VJGS-006SS Sample Type Soil Unit Sample Point Sample Size Peak Locate Threshold Peak Locate Range (in channels) Peak Area Range (in channels) Identification Energy Tolerance Sample Taken On Acquisition Started Live Time Real Time Energy Calibration Used Done On Efficiency Calibration Used Done On 1.274E+03 grams 1.000 keV 120 - 8192 120 - 8192 Detector Name 900.4 seconds 900.0 seconds 9/29/2018 6/20/2019 352 6/18/2019 1:17:00PM 6/20/2019 10:06:48AM Dead Time Efficiency Calibration Description 0.04 % Sample Number

77547 Facility Procedure Default 130G_SOIL_1 Administrator Operator 3.00 Geometry 130G_SOIL_1 Fill Height 1273.52 gram Certificate Name Certificate Date Eu155-Na22 1/7/2013 12:00:00PM 120 8192 Peak Analysis To Channel Peak Analysis From Channel Peak Analysis Performed on PEAK ANALYSIS REPORT 6/20/2019 10:21:52AM

~~~pex-Gamma

Page 2 of 7 6/20/2019 10:22:00AM Analysis Report for L1-12203A-VJGS-006SS 20-Jun-19-10016 Peak No. ROI start ROI end (keV) Energy FWHM (keV) Counts Continuum Uncertainty Net Area Area Net Peak Peak Centroid 1 17.77 5.70E+01 751 9.00E+01 737 744.22 185.88 1.23 2 43.07 2.54E+02 972 6.08E+01 M 948 955.35 238.72 0.95 3 12.88 6.62E+01 972 7.57E+01 m 948 967.35 241.72 0.95 4 15.48 8.14E+01 1189 5.06E+01 1173 1180.73 295.13 0.85 5 12.84 6.24E+01 1359 3.56E+01 1345 1352.50 338.11 0.46 6 18.21 1.64E+02 1416 5.36E+01 1400 1407.47 351.87 1.28 7 11.58 4.20E+01 2048 3.50E+01 2036 2042.91 510.86 0.48 8 11.71 9.40E+01 2341 1.40E+01 2325 2331.78 583.12 1.34 9 13.72 1.34E+02 2443 1.88E+01 2429 2435.97 609.18 1.30 10 6.91 3.07E+01 2916 6.28E+00 2903 2908.46 727.34 0.60 11 11.54 6.80E+01 3652 2.00E+01 3635 3642.87 910.96 0.54 12 7.07 2.57E+01 3882 9.29E+00 3871 3876.05 969.24 0.32 13 22.19 4.79E+02 5854 3.21E+00 5829 5842.19 1460.46 1.91 Errors quoted at 1.000sigma M = First peak in a multiplet region m = Other peak in a multiplet region F = Fitted singlet No background subtract performed on this spectrum. NUCLIDE IDENTIFICATION REPORT Nuclide Library Used C:\\Canberra\\Apex\\Root\\Default\\Library\\ZION LIB-BNL.NLB IDENTIFIED NUCLIDES Id Yield(%) Activity (pCi/grams) Activity Nuclide Name Confidence (keV) Energy Uncertainty 5.04E-02 1.43E-02 An Pk 0.99 100.00 511.00 1.06E+01 6.75E-01 K-40 0.97 10.66 1460.82 1.41E-01 1.95E-02 Tl-208 0.99 85.00 583.19 Bi-212 1.00 1.06 39.86

Page 3 of 7 6/20/2019 10:22:00AM Analysis Report for L1-12203A-VJGS-006SS 20-Jun-19-10016 Id Yield(%) Activity (pCi/grams) Activity Nuclide Name Confidence (keV) Energy Uncertainty 6.82E-01 1.59E-01 6.67 727.33 Bi-212 1.00 1.10 785.37 1.47 1620.50 Pb-212 0.99 0.60 115.18 4.14E-01 7.78E-02 43.60 238.63 3.30 300.09 3.88E-01 4.60E-02 Bi-214 0.99 45.49 609.32 4.89 768.36 1.26 806.18 3.11 934.06 14.92 1120.29 1.63 1155.21 5.83 1238.12 1.43 1280.98 3.99 1377.67 0.79 1385.31 1.33 1401.52 2.39 1407.99 2.13 1509.21 1.05 1661.27 2.88 1729.59 15.30 1764.49 2.03 1847.43 1.16 2118.51 6.53E-01 1.37E-01 Pb-214 0.99 7.25 241.99 3.53E-01 7.29E-02 18.42 295.22 4.18E-01 5.71E-02 35.60 351.93 1.06 785.96 9.93E-01 3.20E-01 Ra-226 0.98 3.64 186.21 Ac-228 0.99 2.42 129.07 3.89 209.25 3.46 270.24 2.95 328.00 4.87E-01 1.08E-01 11.27 338.32 1.92 409.46 4.40 463.00 4.25 794.95 4.53E-01 7.93E-02 25.80 911.20 4.99 964.77 2.92E-01 8.13E-02 15.80 968.97 3.22 1588.20 U-235 0.99 10.96 143.76 5.08 163.33 6.32E-02 2.04E-02 57.20 185.71 1.08 202.11 5.01 205.31

Page 4 of 7 6/20/2019 10:22:00AM Analysis Report for L1-12203A-VJGS-006SS 20-Jun-19-10016 = Energy line found in the spectrum. Nuclide confidence index threshold = 0.30 Errors quoted at 1.000sigma Energy Tolerance : 1.000 keV = Energy line not used for Weighted Mean Activity = Manually added nuclide. = Manually edited nuclide. ? INTERFERENCE CORRECTED REPORT Nuclide Name Nuclide (pCi/grams) Wt mean Activity Comments Confidence Wt mean Activity Uncertainty Id 5.04E-02 1.43E-02 An Pk 0.997 1.06E+01 6.75E-01 K-40 0.979 1.41E-01 1.95E-02 Tl-208 0.999 X Bi-211 0.903 6.82E-01 1.59E-01 Bi-212 1.000 4.14E-01 7.78E-02 Pb-212 0.999 3.88E-01 4.60E-02 Bi-214 0.999 4.18E-01 4.27E-02 Pb-214 0.998 9.93E-01 3.20E-01 ? Ra-226 0.982 3.99E-01 5.02E-02 Ac-228 0.994 6.32E-02 2.04E-02 ? U-235 0.997 Errors quoted at 1.000sigma nuclide contains energy lines not used in Weighted Mean Activity = X = nuclide rejected by the interference analysis nuclide is part of an undetermined solution =

? 

Page 5 of 7 6/20/2019 10:22:00AM Analysis Report for L1-12203A-VJGS-006SS 20-Jun-19-10016 UNIDENTIFIED PEAKS Peak Locate Performed on Peak Locate From Channel Peak Locate To Channel 6/20/2019 10:21:52AM 8192 120 Peak No. Energy (keV) Peak Size (CPS) Peak CPS (%) Uncertainty Peak Type Tolerance Nuclide All peaks were identified. Errors quoted at 1.000sigma F = Fitted singlet m = Other peak in a multiplet region M = First peak in a multiplet region

C:\\Canberra\\Apex\\Root\\Default\\Library\\ZION LIB-BNL.NLB Nuclide Library Used NUCLIDE MDA REPORT Line MDA (pCi/grams)

Yield(%) Nuclide Name Nuclide MDA (pCi/grams) Activity (pCi/grams) (keV) Energy + An Pk 5.04E-02 4.25E-02 4.25E-02 511.00 100.00 BE-7 2.27E-01 4.93E-01 4.93E-01 477.60 10.44 + K-40 1.06E+01 3.41E-01 3.41E-01 1460.82 10.66 Mn-54 2.29E-02 5.93E-02 5.93E-02 834.85 99.98 Co-60 -4.23E-02 6.73E-02 7.82E-02 1173.23 99.85 -2.26E-02 6.73E-02 1332.49 99.98 Nb-94 2.28E-03 5.23E-02 5.23E-02 702.65 99.81 -3.81E-02 5.79E-02 871.09 99.89 Ag-108m 5.13E-01 4.91E-02 1.97E+00 79.13 6.60 -3.41E-02 4.91E-02 433.94 90.50 -5.33E-02 9.79E-02 614.28 89.80 -2.17E-02 7.52E-02 722.94 90.80 Sb-125 -2.04E-01 1.44E-01 5.94E-01 176.31 6.84 -1.18E-01 2.84E+00 380.45 1.52 -2.28E-02 1.44E-01 427.87 29.60 -6.56E-02 4.95E-01 463.36 10.49 8.31E-02 2.59E-01 600.60 17.65 4.36E+00 1.81E+00 606.71 4.98 2.33E-01 4.56E-01 635.95 11.22

Page 6 of 7 6/20/2019 10:22:00AM Analysis Report for L1-12203A-VJGS-006SS 20-Jun-19-10016 Line MDA (pCi/grams) Yield(%) Nuclide Name Nuclide MDA (pCi/grams) Activity (pCi/grams) (keV) Energy -1.81E+00 3.09E+00 671.44 1.79 Sb-125 1.44E-01 Ba-133 9.43E-01 1.06E-01 4.67E+00 79.61 2.65 -3.77E-01 3.27E-01 81.00 32.90 1.57E-02 6.26E-01 276.40 7.16 1.44E-01 2.46E-01 302.85 18.34 2.01E-02 1.06E-01 356.01 62.05 -2.78E-01 4.66E-01 383.85 8.94 Cs-134 2.39E+00 7.59E-02 3.38E+00 475.36 1.48 3.15E-01 5.77E-01 563.25 8.34 -2.80E-02 3.35E-01 569.33 15.37 -2.62E-02 8.53E-02 604.72 97.62 -1.18E-02 7.59E-02 795.86 85.46 -1.13E-01 7.11E-01 801.95 8.69 2.35E+00 6.65E+00 1038.61 0.99 -4.53E-01 4.21E+00 1167.97 1.79 -2.50E-01 1.78E+00 1365.19 3.02 Cs-137 -6.26E-03 6.79E-02 6.79E-02 661.66 85.10 Eu-152 -5.34E-02 1.60E-01 1.79E-01 121.78 28.67 -5.55E-01 6.79E-01 244.70 7.61 1.09E+01 1.28E+01 295.94 0.45 -2.07E-01 1.60E-01 344.28 26.60 1.58E+00 5.10E+00 367.79 0.86 1.17E-02 2.09E+00 411.12 2.24 1.36E+00 1.68E+00 443.96 2.83 -4.81E+00 1.06E+01 488.68 0.42 1.56E+00 9.87E+00 563.99 0.49 2.03E+01 1.59E+01 586.26 0.46 -3.83E+00 1.07E+01 678.62 0.47 4.88E+00 6.55E+00 688.67 0.86 -8.05E-01 2.14E+01 719.35 0.28 -8.83E-01 3.88E-01 778.90 12.96 -1.80E+00 1.57E+01 810.45 0.32 -3.05E+00 1.46E+00 867.37 4.26 -1.46E+01 1.31E+01 919.33 0.43 -1.89E-01 5.28E-01 964.08 14.65 1.65E-01 6.26E-01 1085.87 10.24 -2.14E+00 3.76E+00 1089.74 1.73 -6.16E-01 4.70E-01 1112.07 13.69 2.52E+00 5.41E+00 1212.95 1.43 -4.06E+00 4.08E+01 1249.94 0.19 -7.69E-01 4.29E+00 1299.14 1.63 1.74E-01 3.19E-01 1408.01 21.07 2.14E+02 5.13E+01 1457.64 0.50 -2.82E+00 1.69E+01 1528.10 0.28 Eu-154 5.31E-02 1.29E-01 1.29E-01 123.07 40.40 -2.33E-01 6.17E-01 247.93 6.89 4.84E-01 9.41E-01 591.76 4.95 -8.18E-01 2.97E+00 692.42 1.78 -3.42E-02 3.37E-01 723.30 20.06 2.69E-01 1.29E+00 756.80 4.52 -1.95E-01 4.64E-01 873.18 12.08

Page 7 of 7 6/20/2019 10:22:00AM Analysis Report for L1-12203A-VJGS-006SS 20-Jun-19-10016 Line MDA (pCi/grams) Yield(%) Nuclide Name Nuclide MDA (pCi/grams) Activity (pCi/grams) (keV) Energy -1.85E-01 5.30E-01 996.29 10.48 Eu-154 1.29E-01 -2.90E-02 3.46E-01 1004.76 18.01 -7.69E-02 2.07E-01 1274.43 34.80 -2.05E-01 2.65E+00 1596.48 1.80 Eu-155 -3.91E+00 2.70E-01 2.41E+01 45.30 1.31 -1.66E+01 2.56E+01 60.01 1.22 1.26E-01 3.01E-01 86.55 30.70 5.86E-03 2.70E-01 105.31 21.10 + Ra-226 9.93E-01 1.00E+00 1.00E+00 186.21 3.64 Pa-231 3.50E+00 1.93E+00 2.86E+00 27.36 10.30 1.97E+00 2.46E+00 283.69 1.70 -3.46E-01 1.93E+00 300.07 2.47 1.64E+00 2.07E+00 302.65 2.20 1.47E+00 3.33E+00 330.06 1.40 + U-235 -1.73E-01 6.37E-02 4.05E-01 143.76 10.96 -1.65E-01 8.22E-01 163.33 5.08 6.32E-02 6.37E-02 185.71 57.20 1.26E-01 4.10E+00 202.11 1.08 -4.04E-01 8.69E-01 205.31 5.01 Am-241 3.57E-02 9.20E-01 9.20E-01 59.54 35.90

+ 
= Nuclide identified during the nuclide identification Energy line found in the spectrum
= 
= MDA value not calculated Half-life too short to be able to perform the decay correction
= 
? 
= CAUTION: MDA value is inconsistent with Currie MDA at 95% confidence level

10:25:13AM 6/20/2019 Page 1 of 7 L1-12203A-VJGS-007SS 20-Jun-19-10017 Analysis Report for GAMMA SPECTRUM ANALYSIS Sample Description Sample Identification 20-Jun-19-10017 L1-12203A-VJGS-007SS Sample Type Soil Unit Sample Point Sample Size Peak Locate Threshold Peak Locate Range (in channels) Peak Area Range (in channels) Identification Energy Tolerance Sample Taken On Acquisition Started Live Time Real Time Energy Calibration Used Done On Efficiency Calibration Used Done On 1.386E+03 grams 1.000 keV 120 - 8192 120 - 8192 Detector Name 901.7 seconds 900.0 seconds 1/29/2019 6/20/2019 P40818B 6/18/2019 1:26:00PM 6/20/2019 10:10:02AM Dead Time Efficiency Calibration Description 0.19 % Sample Number

77548 Facility Procedure Default 130G_SOIL_1 Administrator Operator 3.00 Geometry 130G_SOIL_1 Fill Height 1385.97 gram Certificate Name Certificate Date Eu155-Na22 1/30/2012 12:00:00PM 120 8192 Peak Analysis To Channel Peak Analysis From Channel Peak Analysis Performed on PEAK ANALYSIS REPORT 6/20/2019 10:25:06AM

~~~pex-Gamma

Page 2 of 7 6/20/2019 10:25:13AM Analysis Report for L1-12203A-VJGS-007SS 20-Jun-19-10017 Peak No. ROI start ROI end (keV) Energy FWHM (keV) Counts Continuum Uncertainty Net Area Area Net Peak Peak Centroid 1 16.23 4.63E+01 314 9.57E+01 305 309.09 77.09 0.41 2 14.43 3.73E+01 748 7.57E+01 739 743.55 185.82 0.38 3 21.84 2.29E+02 960 8.93E+01 947 954.09 238.50 0.93 4 13.34 7.48E+01 1185 4.32E+01 1175 1179.69 294.95 0.67 5 11.17 3.40E+01 1357 4.00E+01 1348 1352.11 338.08 0.56 6 15.68 1.40E+02 1414 3.99E+01 1402 1406.60 351.72 0.84 7 10.58 7.43E+01 2337 1.37E+01 2324 2330.31 582.78 1.03 8 14.11 1.28E+02 2441 2.37E+01 2426 2434.70 608.88 1.37 9 7.20 3.45E+01 3647 6.48E+00 3635 3641.79 910.71 0.66 10 21.15 4.22E+02 5850 6.23E+00 5827 5838.65 1459.70 2.02 Errors quoted at 1.000sigma M = First peak in a multiplet region m = Other peak in a multiplet region F = Fitted singlet No background subtract performed on this spectrum. NUCLIDE IDENTIFICATION REPORT Nuclide Library Used C:\\Canberra\\Apex\\Root\\Default\\Library\\ZION LIB-BNL.NLB IDENTIFIED NUCLIDES Id Yield(%) Activity (pCi/grams) Activity Nuclide Name Confidence (keV) Energy Uncertainty 1.27E-01 1.97E-02 Tl-208 0.97 85.00 583.19 Pb-212 0.99 0.60 115.18 4.17E-01 5.22E-02 43.60 238.63 3.30 300.09 Pb212-XR 1.00 10.28 74.82 5.74E-01 2.10E-01 17.10 77.11 3.97 87.35

Page 3 of 7 6/20/2019 10:25:13AM Analysis Report for L1-12203A-VJGS-007SS 20-Jun-19-10017 Id Yield(%) Activity (pCi/grams) Activity Nuclide Name Confidence (keV) Energy Uncertainty 1.46 89.78 Pb212-XR 1.00 4.23E-01 5.31E-02 Bi-214 0.98 45.49 609.32 4.89 768.36 1.26 806.18 3.11 934.06 14.92 1120.29 1.63 1155.21 5.83 1238.12 1.43 1280.98 3.99 1377.67 0.79 1385.31 1.33 1401.52 2.39 1407.99 2.13 1509.21 1.05 1661.27 2.88 1729.59 15.30 1764.49 2.03 1847.43 1.16 2118.51 Pb-214 0.99 7.25 241.99 3.64E-01 7.12E-02 18.42 295.22 4.02E-01 5.52E-02 35.60 351.93 1.06 785.96 Pb214-XR 1.00 5.80 74.82 1.01E+00 3.73E-01 9.70 77.11 2.24 87.35 0.82 89.78 7.27E-01 2.88E-01 Ra-226 0.97 3.64 186.21 Ac-228 0.98 2.42 129.07 3.89 209.25 3.46 270.24 2.95 328.00 2.99E-01 1.01E-01 11.27 338.32 1.92 409.46 4.40 463.00 4.25 794.95 2.65E-01 5.64E-02 25.80 911.20 4.99 964.77 15.80 968.97 3.22 1588.20 U-235 0.99 10.96 143.76 5.08 163.33 4.63E-02 1.83E-02 57.20 185.71 1.08 202.11 5.01 205.31

Page 4 of 7 6/20/2019 10:25:13AM Analysis Report for L1-12203A-VJGS-007SS 20-Jun-19-10017 = Energy line found in the spectrum. Nuclide confidence index threshold = 0.30 Errors quoted at 1.000sigma Energy Tolerance : 1.000 keV = Energy line not used for Weighted Mean Activity = Manually added nuclide. = Manually edited nuclide. ? INTERFERENCE CORRECTED REPORT Nuclide Name Nuclide (pCi/grams) Wt mean Activity Comments Confidence Wt mean Activity Uncertainty Id 1.27E-01 1.97E-02 Tl-208 0.973 X Bi-211 0.935 4.17E-01 5.22E-02 Pb-212 0.997 5.74E-01 2.10E-01 ? Pb212-XR 1.000 4.23E-01 5.31E-02 Bi-214 0.988 3.88E-01 4.37E-02 Pb-214 0.992 1.01E+00 3.73E-01 ? Pb214-XR 1.000 7.27E-01 2.88E-01 ? Ra-226 0.975 2.73E-01 4.93E-02 Ac-228 0.987 4.63E-02 1.83E-02 ? U-235 0.999 Errors quoted at 1.000sigma nuclide contains energy lines not used in Weighted Mean Activity = X = nuclide rejected by the interference analysis nuclide is part of an undetermined solution =

? 

Page 5 of 7 6/20/2019 10:25:13AM Analysis Report for L1-12203A-VJGS-007SS 20-Jun-19-10017 UNIDENTIFIED PEAKS Peak Locate Performed on Peak Locate From Channel Peak Locate To Channel 6/20/2019 10:25:06AM 8192 120 Peak No. Energy (keV) Peak Size (CPS) Peak CPS (%) Uncertainty Peak Type Tolerance Nuclide 10 1459.70 4.68632E-01 5.02 Errors quoted at 1.000sigma F = Fitted singlet m = Other peak in a multiplet region M = First peak in a multiplet region

C:\\Canberra\\Apex\\Root\\Default\\Library\\ZION LIB-BNL.NLB Nuclide Library Used NUCLIDE MDA REPORT Line MDA (pCi/grams)

Yield(%) Nuclide Name Nuclide MDA (pCi/grams) Activity (pCi/grams) (keV) Energy An Pk 8.76E-02 6.89E-02 6.89E-02 511.00 100.00 BE-7 9.64E-02 5.31E-01 5.31E-01 477.60 10.44 K-40 1.12E+01 2.65E+00 2.65E+00 1460.82 10.66 Mn-54 2.05E-02 5.92E-02 5.92E-02 834.85 99.98 Co-60 -1.76E-03 6.62E-02 8.81E-02 1173.23 99.85 2.62E-02 6.62E-02 1332.49 99.98 Nb-94 -6.58E-03 5.32E-02 5.32E-02 702.65 99.81 3.30E-03 6.07E-02 871.09 99.89 Ag-108m 6.40E-02 5.08E-02 2.24E+00 79.13 6.60 2.07E-02 5.08E-02 433.94 90.50 -4.78E-02 7.74E-02 614.28 89.80 9.74E-04 6.31E-02 722.94 90.80 Sb-125 3.87E-01 1.53E-01 7.16E-01 176.31 6.84 -8.45E-01 2.76E+00 380.45 1.52 -4.04E-02 1.53E-01 427.87 29.60 2.65E-01 5.09E-01 463.36 10.49 9.25E-02 3.07E-01 600.60 17.65 2.52E+00 2.00E+00 606.71 4.98

Page 6 of 7 6/20/2019 10:25:13AM Analysis Report for L1-12203A-VJGS-007SS 20-Jun-19-10017 Line MDA (pCi/grams) Yield(%) Nuclide Name Nuclide MDA (pCi/grams) Activity (pCi/grams) (keV) Energy -3.94E-02 3.90E-01 635.95 11.22 Sb-125 1.53E-01 -1.63E+00 2.77E+00 671.44 1.79 Ba-133 5.96E-01 8.94E-02 5.19E+00 79.61 2.65 -3.41E-01 3.37E-01 81.00 32.90 1.90E-01 6.12E-01 276.40 7.16 1.36E-01 2.58E-01 302.85 18.34 -1.57E-02 8.94E-02 356.01 62.05 -2.51E-01 4.68E-01 383.85 8.94 Cs-134 -1.37E-01 7.84E-02 3.66E+00 475.36 1.48 -2.07E-01 6.17E-01 563.25 8.34 -2.51E-02 3.65E-01 569.33 15.37 -2.29E-02 1.01E-01 604.72 97.62 6.44E-02 7.84E-02 795.86 85.46 1.52E-01 6.35E-01 801.95 8.69 -2.57E-01 6.08E+00 1038.61 0.99 2.54E+00 4.63E+00 1167.97 1.79 5.40E-01 2.06E+00 1365.19 3.02 Cs-137 5.33E-02 7.30E-02 7.30E-02 661.66 85.10 Eu-152 2.78E-02 1.59E-01 1.81E-01 121.78 28.67 9.07E-02 6.77E-01 244.70 7.61 8.24E+00 1.33E+01 295.94 0.45 -1.71E-01 1.59E-01 344.28 26.60 -4.17E+00 4.54E+00 367.79 0.86 -1.38E+00 2.04E+00 411.12 2.24 -6.61E-01 1.69E+00 443.96 2.83 6.57E+00 1.24E+01 488.68 0.42 -2.13E-02 1.08E+01 563.99 0.49 -2.55E+00 1.77E+01 586.26 0.46 8.91E-01 1.18E+01 678.62 0.47 1.94E+00 6.60E+00 688.67 0.86 1.95E+00 2.05E+01 719.35 0.28 -8.57E-02 4.55E-01 778.90 12.96 -5.97E+00 1.71E+01 810.45 0.32 4.87E-01 1.47E+00 867.37 4.26 3.72E+00 1.47E+01 919.33 0.43 7.66E-03 5.88E-01 964.08 14.65 2.31E-01 7.78E-01 1085.87 10.24 1.24E+00 4.48E+00 1089.74 1.73 -3.62E-01 4.96E-01 1112.07 13.69 -8.41E-01 5.84E+00 1212.95 1.43 -1.30E+01 3.89E+01 1249.94 0.19 7.04E-01 4.00E+00 1299.14 1.63 -2.44E-01 3.01E-01 1408.01 21.07 2.15E+02 5.60E+01 1457.64 0.50 -1.65E+01 1.37E+01 1528.10 0.28 Eu-154 6.32E-02 1.30E-01 1.30E-01 123.07 40.40 -2.49E-01 6.28E-01 247.93 6.89 2.82E-01 1.14E+00 591.76 4.95 3.69E-01 3.40E+00 692.42 1.78 1.98E-01 2.92E-01 723.30 20.06 5.35E-01 1.27E+00 756.80 4.52

Page 7 of 7 6/20/2019 10:25:13AM Analysis Report for L1-12203A-VJGS-007SS 20-Jun-19-10017 Line MDA (pCi/grams) Yield(%) Nuclide Name Nuclide MDA (pCi/grams) Activity (pCi/grams) (keV) Energy 1.13E-01 5.03E-01 873.18 12.08 Eu-154 1.30E-01 1.71E-01 5.94E-01 996.29 10.48 1.11E-02 3.21E-01 1004.76 18.01 -5.06E-03 2.11E-01 1274.43 34.80 5.26E-02 2.55E+00 1596.48 1.80 Eu-155 1.04E+01 3.13E-01 3.67E+01 45.30 1.31 9.18E+00 3.51E+01 60.01 1.22 1.38E-01 3.23E-01 86.55 30.70 -2.30E-02 3.13E-01 105.31 21.10 + Ra-226 7.27E-01 9.22E-01 9.22E-01 186.21 3.64 Pa-231 3.84E+00 1.78E+00 4.16E+00 27.36 10.30 1.75E+00 2.71E+00 283.69 1.70 -1.07E+00 1.78E+00 300.07 2.47 3.71E-01 2.11E+00 302.65 2.20 -1.38E+00 3.13E+00 330.06 1.40 + U-235 9.06E-02 5.86E-02 4.77E-01 143.76 10.96 -2.75E-01 9.19E-01 163.33 5.08 4.63E-02 5.86E-02 185.71 57.20 -3.27E+00 4.01E+00 202.11 1.08 -6.22E-01 8.94E-01 205.31 5.01 Am-241 -3.68E-01 1.24E+00 1.24E+00 59.54 35.90

+ 
= Nuclide identified during the nuclide identification Energy line found in the spectrum
= 
= MDA value not calculated Half-life too short to be able to perform the decay correction
= 
? 
= CAUTION: MDA value is inconsistent with Currie MDA at 95% confidence level

10:34:46AM 6/20/2019 Page 1 of 7 L1-12203A-VJGS-008SS 20-Jun-19-10018 Analysis Report for GAMMA SPECTRUM ANALYSIS Sample Description Sample Identification 20-Jun-19-10018 L1-12203A-VJGS-008SS Sample Type Soil Unit Sample Point Sample Size Peak Locate Threshold Peak Locate Range (in channels) Peak Area Range (in channels) Identification Energy Tolerance Sample Taken On Acquisition Started Live Time Real Time Energy Calibration Used Done On Efficiency Calibration Used Done On 1.365E+03 grams 1.000 keV 120 - 8192 120 - 8192 Detector Name 900.3 seconds 900.0 seconds 1/24/2019 6/20/2019 P11314 6/18/2019 1:42:00PM 6/20/2019 10:19:36AM Dead Time Efficiency Calibration Description 0.04 % Sample Number

77549 Facility Procedure Default 130G_SOIL_1 Administrator Operator 3.00 Geometry 130G_SOIL_1 Fill Height 1364.74 gram Certificate Name Certificate Date Eu155-Na22 12/22/2008 12:00:00PM 120 8192 Peak Analysis To Channel Peak Analysis From Channel Peak Analysis Performed on PEAK ANALYSIS REPORT 6/20/2019 10:34:39AM

~~~pex-Gamma

Page 2 of 7 6/20/2019 10:34:46AM Analysis Report for L1-12203A-VJGS-008SS 20-Jun-19-10018 Peak No. ROI start ROI end (keV) Energy FWHM (keV) Counts Continuum Uncertainty Net Area Area Net Peak Peak Centroid 1 19.86 1.00E+02 316 1.20E+02 306 310.14 77.40 1.12 2 22.81 2.82E+02 960 9.00E+01 948 955.14 238.89 1.09 3 15.75 1.33E+02 1187 4.54E+01 1176 1180.86 295.39 1.10 4 12.87 6.62E+01 1360 3.18E+01 1344 1352.60 338.38 0.81 5 19.79 2.12E+02 1414 5.98E+01 1399 1406.98 351.99 1.34 6 12.64 9.87E+01 2338 2.14E+01 2324 2330.88 583.19 1.40 7 14.38 1.65E+02 2444 1.31E+01 2427 2435.06 609.25 1.19 8 7.33 2.36E+01 2910 1.24E+01 2900 2905.29 726.89 0.58 9 10.81 7.27E+01 3650 1.43E+01 3634 3641.98 911.13 1.03 10 9.22 4.32E+01 3879 1.38E+01 3864 3872.47 968.76 0.60 11 23.19 5.23E+02 5852 3.41E+00 5827 5839.28 1460.34 1.64 Errors quoted at 1.000sigma M = First peak in a multiplet region m = Other peak in a multiplet region F = Fitted singlet No background subtract performed on this spectrum. NUCLIDE IDENTIFICATION REPORT Nuclide Library Used C:\\Canberra\\Apex\\Root\\Default\\Library\\ZION LIB-BNL.NLB IDENTIFIED NUCLIDES Id Yield(%) Activity (pCi/grams) Activity Nuclide Name Confidence (keV) Energy Uncertainty 1.22E+01 7.55E-01 K-40 0.96 10.66 1460.82 1.53E-01 2.17E-02 Tl-208 1.00 85.00 583.19 Bi-212 0.98 1.06 39.86 5.43E-01 1.72E-01 6.67 727.33 1.10 785.37 1.47 1620.50

Page 3 of 7 6/20/2019 10:34:46AM Analysis Report for L1-12203A-VJGS-008SS 20-Jun-19-10018 Id Yield(%) Activity (pCi/grams) Activity Nuclide Name Confidence (keV) Energy Uncertainty Pb-212 0.99 0.60 115.18 4.59E-01 5.25E-02 43.60 238.63 3.30 300.09 Pb212-XR 0.99 10.28 74.82 7.09E-01 1.58E-01 17.10 77.11 3.97 87.35 1.46 89.78 4.93E-01 5.22E-02 Bi-214 1.00 45.49 609.32 4.89 768.36 1.26 806.18 3.11 934.06 14.92 1120.29 1.63 1155.21 5.83 1238.12 1.43 1280.98 3.99 1377.67 0.79 1385.31 1.33 1401.52 2.39 1407.99 2.13 1509.21 1.05 1661.27 2.88 1729.59 15.30 1764.49 2.03 1847.43 1.16 2118.51 Pb-214 0.99 7.25 241.99 5.82E-01 8.33E-02 18.42 295.22 5.49E-01 6.75E-02 35.60 351.93 1.06 785.96 Pb214-XR 0.99 5.80 74.82 1.25E+00 2.85E-01 9.70 77.11 2.24 87.35 0.82 89.78 Ac-228 0.99 2.42 129.07 3.89 209.25 3.46 270.24 2.95 328.00 5.26E-01 1.11E-01 11.27 338.32 1.92 409.46 4.40 463.00 4.25 794.95 5.06E-01 7.82E-02 25.80 911.20 4.99 964.77 5.11E-01 1.11E-01 15.80 968.97 3.22 1588.20

Page 4 of 7 6/20/2019 10:34:46AM Analysis Report for L1-12203A-VJGS-008SS 20-Jun-19-10018 = Energy line found in the spectrum. Nuclide confidence index threshold = 0.30 Errors quoted at 1.000sigma Energy Tolerance : 1.000 keV = Energy line not used for Weighted Mean Activity = Manually added nuclide. = Manually edited nuclide. ? INTERFERENCE CORRECTED REPORT Nuclide Name Nuclide (pCi/grams) Wt mean Activity Comments Confidence Wt mean Activity Uncertainty Id 1.22E+01 7.55E-01 K-40 0.963 1.53E-01 2.17E-02 Tl-208 1.000 X Bi-211 0.873 5.43E-01 1.72E-01 Bi-212 0.980 4.59E-01 5.25E-02 Pb-212 0.990 7.09E-01 1.58E-01 ? Pb212-XR 0.993 4.93E-01 5.22E-02 Bi-214 1.000 5.62E-01 5.24E-02 Pb-214 0.998 1.25E+00 2.85E-01 ? Pb214-XR 0.993 5.12E-01 5.54E-02 Ac-228 0.998 Errors quoted at 1.000sigma nuclide contains energy lines not used in Weighted Mean Activity = X = nuclide rejected by the interference analysis nuclide is part of an undetermined solution =

? 

Page 5 of 7 6/20/2019 10:34:46AM Analysis Report for L1-12203A-VJGS-008SS 20-Jun-19-10018 UNIDENTIFIED PEAKS Peak Locate Performed on Peak Locate From Channel Peak Locate To Channel 6/20/2019 10:34:39AM 8192 120 Peak No. Energy (keV) Peak Size (CPS) Peak CPS (%) Uncertainty Peak Type Tolerance Nuclide All peaks were identified. Errors quoted at 1.000sigma F = Fitted singlet m = Other peak in a multiplet region M = First peak in a multiplet region

C:\\Canberra\\Apex\\Root\\Default\\Library\\ZION LIB-BNL.NLB Nuclide Library Used NUCLIDE MDA REPORT Line MDA (pCi/grams)

Yield(%) Nuclide Name Nuclide MDA (pCi/grams) Activity (pCi/grams) (keV) Energy An Pk 9.07E-02 6.99E-02 6.99E-02 511.00 100.00 BE-7 2.79E-01 5.03E-01 5.03E-01 477.60 10.44 + K-40 1.22E+01 3.73E-01 3.73E-01 1460.82 10.66 Mn-54 5.52E-03 6.18E-02 6.18E-02 834.85 99.98 Co-60 9.37E-03 5.75E-02 7.53E-02 1173.23 99.85 3.23E-02 5.75E-02 1332.49 99.98 Nb-94 -2.00E-03 4.82E-02 4.82E-02 702.65 99.81 6.57E-03 5.36E-02 871.09 99.89 Ag-108m -6.49E-01 4.95E-02 1.55E+00 79.13 6.60 -5.79E-02 4.95E-02 433.94 90.50 -2.00E-02 8.10E-02 614.28 89.80 -4.49E-02 6.48E-02 722.94 90.80 Sb-125 2.08E-01 1.65E-01 5.88E-01 176.31 6.84 3.02E-01 2.90E+00 380.45 1.52 -7.09E-02 1.65E-01 427.87 29.60 2.42E-01 4.99E-01 463.36 10.49 1.23E-01 3.01E-01 600.60 17.65 -3.51E-02 1.97E+00 606.71 4.98 2.64E-01 4.64E-01 635.95 11.22

Page 6 of 7 6/20/2019 10:34:46AM Analysis Report for L1-12203A-VJGS-008SS 20-Jun-19-10018 Line MDA (pCi/grams) Yield(%) Nuclide Name Nuclide MDA (pCi/grams) Activity (pCi/grams) (keV) Energy -4.88E-01 2.47E+00 671.44 1.79 Sb-125 1.65E-01 Ba-133 -9.73E-01 9.66E-02 3.82E+00 79.61 2.65 -1.81E-02 2.56E-01 81.00 32.90 4.28E-01 6.08E-01 276.40 7.16 2.61E-02 2.39E-01 302.85 18.34 -5.41E-02 9.66E-02 356.01 62.05 2.12E-01 4.94E-01 383.85 8.94 Cs-134 3.27E+00 7.66E-02 3.65E+00 475.36 1.48 -6.50E-01 5.85E-01 563.25 8.34 -2.32E-03 2.84E-01 569.33 15.37 -9.13E-04 8.36E-02 604.72 97.62 3.65E-02 7.66E-02 795.86 85.46 -7.93E-01 6.77E-01 801.95 8.69 2.25E+00 6.58E+00 1038.61 0.99 1.60E+00 3.93E+00 1167.97 1.79 1.54E-01 1.68E+00 1365.19 3.02 Cs-137 4.42E-02 6.51E-02 6.51E-02 661.66 85.10 Eu-152 7.22E-03 1.53E-01 1.54E-01 121.78 28.67 1.57E-01 6.61E-01 244.70 7.61 1.96E+01 1.39E+01 295.94 0.45 -2.56E-03 1.53E-01 344.28 26.60 2.40E+00 4.81E+00 367.79 0.86 -5.52E-01 2.12E+00 411.12 2.24 2.04E-01 1.61E+00 443.96 2.83 -4.93E-01 1.08E+01 488.68 0.42 -1.13E+01 9.20E+00 563.99 0.49 -2.47E+00 1.77E+01 586.26 0.46 -2.33E+00 1.10E+01 678.62 0.47 4.84E+00 6.51E+00 688.67 0.86 3.42E+00 1.75E+01 719.35 0.28 -4.08E-02 4.31E-01 778.90 12.96 -4.29E+00 1.69E+01 810.45 0.32 7.93E-01 1.44E+00 867.37 4.26 3.97E-01 1.38E+01 919.33 0.43 1.08E-01 6.03E-01 964.08 14.65 -1.00E+00 6.91E-01 1085.87 10.24 -2.70E+00 4.38E+00 1089.74 1.73 -2.68E-01 5.09E-01 1112.07 13.69 3.82E-01 5.90E+00 1212.95 1.43 -7.28E+00 4.23E+01 1249.94 0.19 -4.96E+00 4.14E+00 1299.14 1.63 -2.94E-02 2.72E-01 1408.01 21.07 2.60E+02 5.59E+01 1457.64 0.50 -3.11E+00 1.71E+01 1528.10 0.28 Eu-154 1.34E-02 1.10E-01 1.10E-01 123.07 40.40 8.61E-02 6.16E-01 247.93 6.89 -2.10E-01 1.01E+00 591.76 4.95 6.69E-01 2.99E+00 692.42 1.78 -1.45E-01 2.98E-01 723.30 20.06 7.07E-01 1.30E+00 756.80 4.52 -5.41E-01 4.56E-01 873.18 12.08

Page 7 of 7 6/20/2019 10:34:46AM Analysis Report for L1-12203A-VJGS-008SS 20-Jun-19-10018 Line MDA (pCi/grams) Yield(%) Nuclide Name Nuclide MDA (pCi/grams) Activity (pCi/grams) (keV) Energy 3.18E-01 5.61E-01 996.29 10.48 Eu-154 1.10E-01 -1.00E-01 3.41E-01 1004.76 18.01 1.16E-01 2.17E-01 1274.43 34.80 2.22E+00 3.18E+00 1596.48 1.80 Eu-155 -1.01E+01 2.34E-01 1.30E+01 45.30 1.31 -7.88E+00 1.56E+01 60.01 1.22 -1.41E-01 2.34E-01 86.55 30.70 2.00E-02 2.39E-01 105.31 21.10 Ra-226 1.27E+00 1.32E+00 1.32E+00 186.21 3.64 Pa-231 2.17E+00 1.74E+00 1.74E+00 27.36 10.30 -2.03E+00 2.21E+00 283.69 1.70 -3.89E-01 1.88E+00 300.07 2.47 4.68E-02 1.99E+00 302.65 2.20 1.14E+00 3.10E+00 330.06 1.40 U-235 8.46E-02 8.29E-02 3.99E-01 143.76 10.96 -1.85E-01 8.13E-01 163.33 5.08 4.48E-02 8.29E-02 185.71 57.20 -1.19E+00 3.49E+00 202.11 1.08 -3.29E-01 7.39E-01 205.31 5.01 Am-241 -3.23E-01 5.49E-01 5.49E-01 59.54 35.90

+ 
= Nuclide identified during the nuclide identification Energy line found in the spectrum
= 
= MDA value not calculated Half-life too short to be able to perform the decay correction
= 
? 
= CAUTION: MDA value is inconsistent with Currie MDA at 95% confidence level FSS AREA ACCESS REQUEST, AUTHORIZATION AND SIGN-IN SHEET REQUEST FOR ACCESS:

ZS-LT-300-001-003 Revision 6 Information Use Survey Area No.: _12_0_0_0 _______ _ Survey Unit No.: 12203B Survey Unit Type: Open Land IZI Structure D System D Work Group

Contact:

Final Status Survey (FSS), supervisor Radio RP-3. Description of Planned Activities: This is the 1st Bi-annual surveillance survey for this survey unit. Duration: Start 8/1/19 Stop 8/1/19 Access Controls Required:

1. All personnel will brief and sign in/out on this FSS Attachment 2.
2. All personnel and equipment will be surveyed into the area by the FSS technician.
3. There will be a minimum of one scheduled biased surface soil sample taken in this survey unit.
4. When job is completed, the survey unit postings will be verified sat* act~

.. t\\Jw~ Survey Unit# Name (Pnnt/S1gn) Reason for Entry Date Time Time In Out 12203B FSS technician 8-1-19 v;*. / 5 JO: 'J-5 \\-<l\\'l,"l.'. ta*. "-I a. litb-...~S..., (t:t- <l - ~ I 'f /3 : ~ '""'-~~ ~- )- 19' )J:YJ. ~-O~*C 'S,~, 1 /?.. ~ .,) -, PS I )(-/-1'1 \\J:_lf ~ /'1 -~7 /RAw-c,.~5'; -:r-Page/ of Y FSS I&C Surveillance Summary AREA SURVEILLANCE: Survey Area No.: 12000 Survey Unit No.:

== Description:== Performing 1st Bi-Annual surveillance survey. Survey Unit Type: Structure D ZS-L T-300-001-003 Revision6 Information Use 12203B System Classification: Open Land !ZI Class3 D Class2 D Class 1 !ZI Reason for Surveillance: Semi-Annual !ZI Special D Surveillance Due Date: 7-10-19 Reason: Bi-annual Surveillance survey. (Survey Date surveillance performed: 8-1-19 performed after due date because the storage and removal of the CCDD pile in the adjacent survey area 12205). SURVEILLANCE ACTIVITIES: I) Review ZS-LT-300-001-003 Attachment 2, FSS Area Access Request, Authorization and Sign-In Sheet for authorized entries into the FSS Survey Unit--------*********************************************************--------*----*---*----*----*- ~

2) Perform a walk down of the FSS Survey Unit and identify decommissioning activities adjacent survey units that could have a reasonable potential to spread radioactive material to the FSS Survey Unit.--************** ~

SURVEILLANCE COMMENTS AND OBSERVATIONS: This survey unit was part of the traverse path to remove the CCDD pile. The CCDD is now removed, and the surveillance survey is being performed. The FSS technician will perform the planned surveillance survey (walk down and sample), but will also include a gamma walk over survey on the traverse path. The laborer support will be available after lunch, so the FSS technician will be going in and perform the walk down and complete the gamma walk over survey. Informed the MBI foreman (N.Friant). 08: 15 The FSS technician signed in and surveyed all the sampling equipment into the survey unit. The FSS technician established the scan area and started with verifying the backgrounds. The west side has a higher background due the media having more clay surface, so there will be two set of backgrounds making two scan areas, #1 and #2. Scan Area #I backgrounds: 2103, 2117, 2208, 2284, and 2116 cpm, AVG 2166 cpm, MDCR 497 cpm, and ASP 2663 cpm. Scan Area #2backgrounds: 3003, 3526, 3590, 3572, and 3413 cpm, AVG 3421 cpm, MDCR 625 cpm, and ASP 4046 cpm. Completed the gamma walk over scan, lunch. 12:30 MBI laborer support (RD, AV) joined the FSS technician to complete this survey. The group signed/surveyed into the surve unit. 13:00 Collected biased surface soil sample #LI l2203BVJGS001SS.

== Description:== medium brown sand, and gravel. Location selected in scan area # 1. 13: 11 Collected biased surface soil sample #Ll 12203BVJGS002SS.

== Description:== medium brown sand, clay, and gravel. Location selected in scan area #2. 13:28 Collected biased surface soil sample #Ll 12203BVJGS003SS.

== Description:== light brown sand, and gravel. Location selected in the road that is the main entry for the survey unit. 13:38 Completed surveillance in this survey unit. The group signed out of the survey unit. The collected samples were brought to the sample prep trailer for processing. FSS l&C Surveillance Summary ZS-LT-300-001-003 Revision 6 Information Use Continuation for survey unit 12203B 1st surveillance survey. Notes: The sample locations and the scan area was OPS' d, and the corrected coordinate with the location will be shown on the attached map. The meter used for the scan area was a Model 2350-1/ #266656 with a 44-10 probe #PR311750 (with 3" collimator), cal due 7-24-20. All scan results were; no detectable above background/no alarms. The 2350-1 meter passed pre and post source check. There were some small pieces of plastic/metal, and old flags/rope that was surveyed and removed from the survey unit. The postings were satisfactory. The postings are represented on the adjacent connecting FSS survey units. A Model 3 #283228 with a 44-9/PR355606, cal due 1-12-20 was used for all the surveying. All survey results were indistinguishable from background. Background 30-50 cpm. I !8J-Surveillance Satisfactory I 0- Surveillance Un-Satisfactory Karen Nicholso 9-4-19 16:00 (Time)

0 I,() c.o .... i 0 N (0 ~ 343680 L 112203BVJGS002SS 641649.87

J.-~'--~

343685.82 Legend D Survey Unit (SU) 12203B (1,989 m2) ~ Biased Surface Samples Refusal 343710 _j;_...... _

I, -\\*'.

20

  • o Feet 10Meters Final Status Survey Surveillance 122038 NAD83 IL State Plane East 1201 (Meters) 2017 Aerials - Lake County GIS Dept.

Date performed: 08/01/2019 Drawing; FSS SURV122038 080119

8:01:34AM 8/15/2019 Page 1 of 7 L1-12203B-VJGS-001SS 15-Aug-19-10016 Analysis Report for GAMMA SPECTRUM ANALYSIS Sample Description Sample Identification 15-Aug-19-10016 L1-12203B-VJGS-001SS Sample Type Soil Unit Sample Point Sample Size Peak Locate Threshold Peak Locate Range (in channels) Peak Area Range (in channels) Identification Energy Tolerance Sample Taken On Acquisition Started Live Time Real Time Energy Calibration Used Done On Efficiency Calibration Used Done On 1.623E+03 grams 1.000 keV 120 - 8192 120 - 8192 Detector Name 900.3 seconds 900.0 seconds 9/29/2018 8/15/2019 352 8/1/2019 1:00:00PM 8/15/2019 7:46:22AM Dead Time Efficiency Calibration Description 0.03 % Sample Number

78806 Facility Procedure Default 130G_SOIL_1 Administrator Operator 3.00 Geometry 130G_SOIL_1 Fill Height 1623.14 gram Certificate Name Certificate Date Eu155-Na22 1/7/2013 12:00:00PM 120 8192 Peak Analysis To Channel Peak Analysis From Channel Peak Analysis Performed on PEAK ANALYSIS REPORT 8/15/2019 8:01:25AM

~~~pex-Gamma

Page 2 of 7 8/15/2019 8:01:34AM Analysis Report for L1-12203B-VJGS-001SS 15-Aug-19-10016 Peak No. ROI start ROI end (keV) Energy FWHM (keV) Counts Continuum Uncertainty Net Area Area Net Peak Peak Centroid 1 18.41 1.19E+02 960 8.00E+01 947 955.19 238.68 0.76 2 12.11 6.51E+01 1187 3.09E+01 1175 1181.52 295.32 0.82 3 14.65 7.55E+01 1415 4.45E+01 1399 1407.82 351.96 0.60 4 9.76 2.44E+01 2049 2.66E+01 2037 2042.49 510.75 0.29 5 9.99 4.95E+01 2340 1.75E+01 2326 2331.76 583.11 0.99 6 11.73 8.89E+01 2443 1.61E+01 2428 2436.52 609.31 1.30 7 8.96 4.62E+01 3652 1.08E+01 3636 3644.14 911.27 0.51 8 20.59 3.86E+02 5854 9.30E+00 5830 5843.17 1460.70 1.94 Errors quoted at 1.000sigma M = First peak in a multiplet region m = Other peak in a multiplet region F = Fitted singlet No background subtract performed on this spectrum. NUCLIDE IDENTIFICATION REPORT Nuclide Library Used C:\\Canberra\\Apex\\Root\\Default\\Library\\ZION LIB-BNL.NLB IDENTIFIED NUCLIDES Id Yield(%) Activity (pCi/grams) Activity Nuclide Name Confidence (keV) Energy Uncertainty 3.21E-02 1.31E-02 An Pk 0.99 100.00 511.00 7.95E+00 5.47E-01 K-40 0.99 10.66 1460.82 6.99E-02 1.47E-02 Tl-208 0.99 85.00 583.19 Pb-212 1.00 0.60 115.18 1.85E-01 3.22E-02 43.60 238.63 3.30 300.09 2.41E-01 3.50E-02 Bi-214 1.00 45.49 609.32 4.89 768.36 1.26 806.18

Page 3 of 7 8/15/2019 8:01:34AM Analysis Report for L1-12203B-VJGS-001SS 15-Aug-19-10016 Id Yield(%) Activity (pCi/grams) Activity Nuclide Name Confidence (keV) Energy Uncertainty 3.11 934.06 Bi-214 1.00 14.92 1120.29 1.63 1155.21 5.83 1238.12 1.43 1280.98 3.99 1377.67 0.79 1385.31 1.33 1401.52 2.39 1407.99 2.13 1509.21 1.05 1661.27 2.88 1729.59 15.30 1764.49 2.03 1847.43 1.16 2118.51 Pb-214 0.99 7.25 241.99 2.68E-01 5.43E-02 18.42 295.22 1.82E-01 3.82E-02 35.60 351.93 1.06 785.96 Ac-228 1.00 2.42 129.07 3.89 209.25 3.46 270.24 2.95 328.00 11.27 338.32 1.92 409.46 4.40 463.00 4.25 794.95 2.88E-01 5.72E-02 25.80 911.20 4.99 964.77 15.80 968.97 3.22 1588.20 = Energy line found in the spectrum. Nuclide confidence index threshold = 0.30 Errors quoted at 1.000sigma Energy Tolerance : 1.000 keV = Energy line not used for Weighted Mean Activity = Manually added nuclide. = Manually edited nuclide. ? INTERFERENCE CORRECTED REPORT

Page 4 of 7 8/15/2019 8:01:34AM Analysis Report for L1-12203B-VJGS-001SS 15-Aug-19-10016 Nuclide Name Nuclide (pCi/grams) Wt mean Activity Comments Confidence Wt mean Activity Uncertainty Id 3.21E-02 1.31E-02 An Pk 0.990 7.95E+00 5.47E-01 K-40 0.998 6.99E-02 1.47E-02 Tl-208 0.999 X Bi-211 0.882 1.85E-01 3.22E-02 Pb-212 1.000 2.41E-01 3.50E-02 Bi-214 1.000 2.10E-01 3.12E-02 Pb-214 0.999 2.88E-01 5.72E-02 Ac-228 1.000 Errors quoted at 1.000sigma nuclide contains energy lines not used in Weighted Mean Activity = X = nuclide rejected by the interference analysis nuclide is part of an undetermined solution =

? 

Page 5 of 7 8/15/2019 8:01:34AM Analysis Report for L1-12203B-VJGS-001SS 15-Aug-19-10016 UNIDENTIFIED PEAKS Peak Locate Performed on Peak Locate From Channel Peak Locate To Channel 8/15/2019 8:01:25AM 8192 120 Peak No. Energy (keV) Peak Size (CPS) Peak CPS (%) Uncertainty Peak Type Tolerance Nuclide All peaks were identified. Errors quoted at 1.000sigma F = Fitted singlet m = Other peak in a multiplet region M = First peak in a multiplet region

C:\\Canberra\\Apex\\Root\\Default\\Library\\ZION LIB-BNL.NLB Nuclide Library Used NUCLIDE MDA REPORT Line MDA (pCi/grams)

Yield(%) Nuclide Name Nuclide MDA (pCi/grams) Activity (pCi/grams) (keV) Energy + An Pk 3.21E-02 4.15E-02 4.15E-02 511.00 100.00 BE-7 -3.18E-02 4.61E-01 4.61E-01 477.60 10.44 + K-40 7.95E+00 4.91E-01 4.91E-01 1460.82 10.66 Mn-54 -1.83E-02 4.49E-02 4.49E-02 834.85 99.98 Co-60 3.35E-02 4.16E-02 7.13E-02 1173.23 99.85 -1.51E-03 4.16E-02 1332.49 99.98 Nb-94 -1.47E-02 4.48E-02 4.51E-02 702.65 99.81 2.37E-02 4.48E-02 871.09 99.89 Ag-108m -1.10E-01 4.20E-02 1.57E+00 79.13 6.60 -1.74E-02 4.20E-02 433.94 90.50 -5.67E-02 7.64E-02 614.28 89.80 9.02E-04 5.80E-02 722.94 90.80 Sb-125 -1.14E-01 1.38E-01 5.39E-01 176.31 6.84 9.14E-01 2.37E+00 380.45 1.52 1.20E-03 1.38E-01 427.87 29.60 -5.92E-02 3.72E-01 463.36 10.49 -1.77E-01 2.38E-01 600.60 17.65 1.81E+00 1.45E+00 606.71 4.98 -2.60E-01 3.53E-01 635.95 11.22

Page 6 of 7 8/15/2019 8:01:34AM Analysis Report for L1-12203B-VJGS-001SS 15-Aug-19-10016 Line MDA (pCi/grams) Yield(%) Nuclide Name Nuclide MDA (pCi/grams) Activity (pCi/grams) (keV) Energy -4.92E+00 2.32E+00 671.44 1.79 Sb-125 1.38E-01 Ba-133 9.48E-01 8.15E-02 3.85E+00 79.61 2.65 -4.75E-01 2.72E-01 81.00 32.90 -4.89E-01 5.33E-01 276.40 7.16 1.16E-01 2.07E-01 302.85 18.34 4.93E-03 8.15E-02 356.01 62.05 8.69E-02 4.05E-01 383.85 8.94 Cs-134 1.90E+00 5.65E-02 2.79E+00 475.36 1.48 -7.13E-02 4.51E-01 563.25 8.34 -2.00E-01 2.50E-01 569.33 15.37 -5.76E-03 7.07E-02 604.72 97.62 -1.21E-03 5.65E-02 795.86 85.46 -6.03E-01 5.02E-01 801.95 8.69 3.31E+00 5.74E+00 1038.61 0.99 -2.40E-01 3.50E+00 1167.97 1.79 5.26E-02 1.50E+00 1365.19 3.02 Cs-137 1.05E-02 4.79E-02 4.79E-02 661.66 85.10 Eu-152 2.98E-02 1.40E-01 1.40E-01 121.78 28.67 3.50E-01 5.52E-01 244.70 7.61 9.63E+00 1.09E+01 295.94 0.45 -9.41E-02 1.41E-01 344.28 26.60 -2.49E+00 3.88E+00 367.79 0.86 5.95E-01 1.81E+00 411.12 2.24 1.91E-01 1.30E+00 443.96 2.83 -4.50E+00 7.10E+00 488.68 0.42 -8.52E+00 7.09E+00 563.99 0.49 1.50E+01 1.30E+01 586.26 0.46 5.11E+00 9.76E+00 678.62 0.47 9.76E-01 5.19E+00 688.67 0.86 1.45E+01 1.75E+01 719.35 0.28 -2.89E-01 3.41E-01 778.90 12.96 2.50E-01 1.41E+01 810.45 0.32 -9.25E-02 1.10E+00 867.37 4.26 -2.75E+00 1.31E+01 919.33 0.43 1.35E-01 4.94E-01 964.08 14.65 -4.22E-02 5.06E-01 1085.87 10.24 2.31E-01 3.27E+00 1089.74 1.73 -2.31E-01 3.90E-01 1112.07 13.69 1.96E+00 5.13E+00 1212.95 1.43 9.92E+00 3.35E+01 1249.94 0.19 -1.78E+00 3.68E+00 1299.14 1.63 -3.30E-02 1.91E-01 1408.01 21.07 1.68E+02 4.34E+01 1457.64 0.50 2.44E+00 1.52E+01 1528.10 0.28 Eu-154 -7.35E-02 9.55E-02 9.55E-02 123.07 40.40 3.83E-02 5.30E-01 247.93 6.89 1.54E-01 7.87E-01 591.76 4.95 -9.19E-01 2.49E+00 692.42 1.78 1.02E-01 2.66E-01 723.30 20.06 -1.27E-01 1.02E+00 756.80 4.52 1.24E-01 3.72E-01 873.18 12.08

Page 7 of 7 8/15/2019 8:01:34AM Analysis Report for L1-12203B-VJGS-001SS 15-Aug-19-10016 Line MDA (pCi/grams) Yield(%) Nuclide Name Nuclide MDA (pCi/grams) Activity (pCi/grams) (keV) Energy 7.34E-02 4.75E-01 996.29 10.48 Eu-154 9.55E-02 -1.82E-01 2.42E-01 1004.76 18.01 2.07E-01 1.82E-01 1274.43 34.80 2.40E-01 2.55E+00 1596.48 1.80 Eu-155 9.32E+00 2.21E-01 2.03E+01 45.30 1.31 -8.94E+00 2.23E+01 60.01 1.22 1.90E-01 2.45E-01 86.55 30.70 -3.53E-02 2.21E-01 105.31 21.10 Ra-226 1.20E+00 1.14E+00 1.14E+00 186.21 3.64 Pa-231 2.56E+00 1.68E+00 2.39E+00 27.36 10.30 -1.60E+00 2.18E+00 283.69 1.70 -1.27E+00 1.68E+00 300.07 2.47 8.90E-01 1.75E+00 302.65 2.20 7.31E-01 2.73E+00 330.06 1.40 U-235 -6.73E-02 7.32E-02 3.65E-01 143.76 10.96 -1.06E-02 6.73E-01 163.33 5.08 6.63E-02 7.32E-02 185.71 57.20 3.75E+00 3.48E+00 202.11 1.08 -5.82E-01 7.08E-01 205.31 5.01 Am-241 1.06E-02 7.78E-01 7.78E-01 59.54 35.90

+ 
= Nuclide identified during the nuclide identification Energy line found in the spectrum
= 
= MDA value not calculated Half-life too short to be able to perform the decay correction
= 
? 
= CAUTION: MDA value is inconsistent with Currie MDA at 95% confidence level

8:17:42AM 8/15/2019 Page 1 of 7 L1-12203B-VJGS-002SS 15-Aug-19-10017 Analysis Report for GAMMA SPECTRUM ANALYSIS Sample Description Sample Identification 15-Aug-19-10017 L1-12203B-VJGS-002SS Sample Type Soil Unit Sample Point Sample Size Peak Locate Threshold Peak Locate Range (in channels) Peak Area Range (in channels) Identification Energy Tolerance Sample Taken On Acquisition Started Live Time Real Time Energy Calibration Used Done On Efficiency Calibration Used Done On 1.578E+03 grams 1.000 keV 120 - 8192 120 - 8192 Detector Name 900.3 seconds 900.0 seconds 9/29/2018 8/15/2019 352 8/1/2019 1:11:00PM 8/15/2019 8:02:30AM Dead Time Efficiency Calibration Description 0.03 % Sample Number

78809 Facility Procedure Default 130G_SOIL_1 Administrator Operator 3.00 Geometry 130G_SOIL_1 Fill Height 1578.02 gram Certificate Name Certificate Date Eu155-Na22 1/7/2013 12:00:00PM 120 8192 Peak Analysis To Channel Peak Analysis From Channel Peak Analysis Performed on PEAK ANALYSIS REPORT 8/15/2019 8:17:32AM

~~~pex-Gamma

Page 2 of 7 8/15/2019 8:17:42AM Analysis Report for L1-12203B-VJGS-002SS 15-Aug-19-10017 Peak No. ROI start ROI end (keV) Energy FWHM (keV) Counts Continuum Uncertainty Net Area Area Net Peak Peak Centroid 1 12.63 4.29E+01 750 4.31E+01 738 744.74 186.00 0.79 2 18.90 1.21E+02 961 8.51E+01 948 955.17 238.68 0.94 3 12.00 6.33E+01 1186 3.07E+01 1174 1181.21 295.25 0.96 4 14.36 1.00E+02 1415 3.40E+01 1399 1407.54 351.89 1.14 5 9.43 5.73E+01 2339 1.17E+01 2327 2332.27 583.24 1.12 6 11.47 9.95E+01 2446 9.50E+00 2428 2436.87 609.40 1.16 7 10.05 4.70E+01 3651 1.80E+01 3636 3643.78 911.18 1.54 8 20.80 4.18E+02 5855 3.42E+00 5829 5843.19 1460.70 2.17 Errors quoted at 1.000sigma M = First peak in a multiplet region m = Other peak in a multiplet region F = Fitted singlet No background subtract performed on this spectrum. NUCLIDE IDENTIFICATION REPORT Nuclide Library Used C:\\Canberra\\Apex\\Root\\Default\\Library\\ZION LIB-BNL.NLB IDENTIFIED NUCLIDES Id Yield(%) Activity (pCi/grams) Activity Nuclide Name Confidence (keV) Energy Uncertainty 8.67E+00 5.73E-01 K-40 0.99 10.66 1460.82 8.15E-02 1.43E-02 Tl-208 1.00 85.00 583.19 Pb-212 1.00 0.60 115.18 1.88E-01 3.31E-02 43.60 238.63 3.30 300.09 2.72E-01 3.53E-02 Bi-214 1.00 45.49 609.32 4.89 768.36 1.26 806.18 3.11 934.06

Page 3 of 7 8/15/2019 8:17:42AM Analysis Report for L1-12203B-VJGS-002SS 15-Aug-19-10017 Id Yield(%) Activity (pCi/grams) Activity Nuclide Name Confidence (keV) Energy Uncertainty 14.92 1120.29 Bi-214 1.00 1.63 1155.21 5.83 1238.12 1.43 1280.98 3.99 1377.67 0.79 1385.31 1.33 1401.52 2.39 1407.99 2.13 1509.21 1.05 1661.27 2.88 1729.59 15.30 1764.49 2.03 1847.43 1.16 2118.51 Pb-214 1.00 7.25 241.99 2.62E-01 5.39E-02 18.42 295.22 2.42E-01 3.98E-02 35.60 351.93 1.06 785.96 7.14E-01 2.18E-01 Ra-226 0.99 3.64 186.21 Ac-228 1.00 2.42 129.07 3.89 209.25 3.46 270.24 2.95 328.00 11.27 338.32 1.92 409.46 4.40 463.00 4.25 794.95 2.95E-01 6.43E-02 25.80 911.20 4.99 964.77 15.80 968.97 3.22 1588.20 U-235 0.99 10.96 143.76 5.08 163.33 4.54E-02 1.39E-02 57.20 185.71 1.08 202.11 5.01 205.31 = Energy line found in the spectrum. Nuclide confidence index threshold = 0.30 Errors quoted at 1.000sigma Energy Tolerance : 1.000 keV = Energy line not used for Weighted Mean Activity = Manually added nuclide. = Manually edited nuclide. ?

Page 4 of 7 8/15/2019 8:17:42AM Analysis Report for L1-12203B-VJGS-002SS 15-Aug-19-10017 INTERFERENCE CORRECTED REPORT Nuclide Name Nuclide (pCi/grams) Wt mean Activity Comments Confidence Wt mean Activity Uncertainty Id 8.67E+00 5.73E-01 K-40 0.998 8.15E-02 1.43E-02 Tl-208 1.000 X Bi-211 0.899 1.88E-01 3.31E-02 Pb-212 1.000 2.72E-01 3.53E-02 Bi-214 1.000 2.49E-01 3.20E-02 Pb-214 1.000 7.14E-01 2.18E-01 ? Ra-226 0.993 2.95E-01 6.43E-02 Ac-228 1.000 4.54E-02 1.39E-02 ? U-235 0.990 Errors quoted at 1.000sigma nuclide contains energy lines not used in Weighted Mean Activity = X = nuclide rejected by the interference analysis nuclide is part of an undetermined solution =

? 

Page 5 of 7 8/15/2019 8:17:42AM Analysis Report for L1-12203B-VJGS-002SS 15-Aug-19-10017 UNIDENTIFIED PEAKS Peak Locate Performed on Peak Locate From Channel Peak Locate To Channel 8/15/2019 8:17:32AM 8192 120 Peak No. Energy (keV) Peak Size (CPS) Peak CPS (%) Uncertainty Peak Type Tolerance Nuclide All peaks were identified. Errors quoted at 1.000sigma F = Fitted singlet m = Other peak in a multiplet region M = First peak in a multiplet region

C:\\Canberra\\Apex\\Root\\Default\\Library\\ZION LIB-BNL.NLB Nuclide Library Used NUCLIDE MDA REPORT Line MDA (pCi/grams)

Yield(%) Nuclide Name Nuclide MDA (pCi/grams) Activity (pCi/grams) (keV) Energy An Pk 8.18E-02 6.82E-02 6.82E-02 511.00 100.00 BE-7 2.15E-01 5.00E-01 5.00E-01 477.60 10.44 + K-40 8.67E+00 3.34E-01 3.34E-01 1460.82 10.66 Mn-54 1.23E-03 5.04E-02 5.04E-02 834.85 99.98 Co-60 -8.14E-03 5.50E-02 5.50E-02 1173.23 99.85 1.45E-02 5.87E-02 1332.49 99.98 Nb-94 -1.25E-02 4.22E-02 4.64E-02 702.65 99.81 2.92E-02 4.22E-02 871.09 99.89 Ag-108m 1.08E-01 4.18E-02 1.56E+00 79.13 6.60 3.70E-02 4.18E-02 433.94 90.50 -3.35E-03 7.56E-02 614.28 89.80 1.03E-02 5.84E-02 722.94 90.80 Sb-125 2.54E-01 1.19E-01 5.27E-01 176.31 6.84 -1.21E+00 2.31E+00 380.45 1.52 -1.07E-01 1.19E-01 427.87 29.60 -2.86E-02 4.09E-01 463.36 10.49 1.19E-02 2.17E-01 600.60 17.65 2.61E+00 1.41E+00 606.71 4.98 9.90E-02 4.07E-01 635.95 11.22

Page 6 of 7 8/15/2019 8:17:42AM Analysis Report for L1-12203B-VJGS-002SS 15-Aug-19-10017 Line MDA (pCi/grams) Yield(%) Nuclide Name Nuclide MDA (pCi/grams) Activity (pCi/grams) (keV) Energy 4.07E-01 2.51E+00 671.44 1.79 Sb-125 1.19E-01 Ba-133 5.28E-02 7.95E-02 3.74E+00 79.61 2.65 -6.81E-01 2.47E-01 81.00 32.90 -2.47E-02 4.98E-01 276.40 7.16 -1.26E-01 1.89E-01 302.85 18.34 -6.09E-02 7.95E-02 356.01 62.05 1.72E-01 4.32E-01 383.85 8.94 Cs-134 1.31E+00 5.62E-02 2.92E+00 475.36 1.48 1.95E-01 4.59E-01 563.25 8.34 7.24E-02 2.60E-01 569.33 15.37 -9.94E-03 6.33E-02 604.72 97.62 4.43E-02 5.62E-02 795.86 85.46 -3.90E-02 5.69E-01 801.95 8.69 1.35E+00 5.48E+00 1038.61 0.99 -1.74E+00 3.48E+00 1167.97 1.79 1.27E+00 1.64E+00 1365.19 3.02 Cs-137 9.19E-03 5.46E-02 5.46E-02 661.66 85.10 Eu-152 8.05E-02 1.43E-01 1.46E-01 121.78 28.67 -2.47E-01 5.48E-01 244.70 7.61 8.46E+00 1.02E+01 295.94 0.45 -8.97E-02 1.43E-01 344.28 26.60 -1.59E-01 3.97E+00 367.79 0.86 -2.25E-01 1.76E+00 411.12 2.24 5.41E-02 1.25E+00 443.96 2.83 2.18E+00 8.98E+00 488.68 0.42 1.18E+00 7.44E+00 563.99 0.49 1.61E+01 1.27E+01 586.26 0.46 -2.59E+00 8.13E+00 678.62 0.47 -2.88E-01 4.29E+00 688.67 0.86 5.53E+00 1.65E+01 719.35 0.28 -3.69E-01 3.24E-01 778.90 12.96 -9.74E+00 1.40E+01 810.45 0.32 -2.70E-01 1.12E+00 867.37 4.26 -6.84E+00 1.27E+01 919.33 0.43 -8.09E-02 4.42E-01 964.08 14.65 -5.76E-02 5.54E-01 1085.87 10.24 -4.23E+00 3.20E+00 1089.74 1.73 -2.85E-01 4.62E-01 1112.07 13.69 3.08E+00 5.34E+00 1212.95 1.43 -3.11E+01 3.11E+01 1249.94 0.19 -8.15E-01 3.18E+00 1299.14 1.63 -6.26E-03 2.38E-01 1408.01 21.07 1.90E+02 4.52E+01 1457.64 0.50 1.16E-01 1.27E+01 1528.10 0.28 Eu-154 -1.84E-02 1.04E-01 1.04E-01 123.07 40.40 3.27E-02 5.55E-01 247.93 6.89 -5.58E-01 7.62E-01 591.76 4.95 1.10E+00 2.29E+00 692.42 1.78 1.29E-01 2.72E-01 723.30 20.06 4.81E-01 9.67E-01 756.80 4.52 -5.80E-02 3.63E-01 873.18 12.08

Page 7 of 7 8/15/2019 8:17:42AM Analysis Report for L1-12203B-VJGS-002SS 15-Aug-19-10017 Line MDA (pCi/grams) Yield(%) Nuclide Name Nuclide MDA (pCi/grams) Activity (pCi/grams) (keV) Energy -3.00E-01 3.99E-01 996.29 10.48 Eu-154 1.04E-01 1.02E-01 2.76E-01 1004.76 18.01 -1.01E-01 1.71E-01 1274.43 34.80 -7.59E-01 2.05E+00 1596.48 1.80 Eu-155 -4.77E+00 2.32E-01 2.14E+01 45.30 1.31 2.27E+00 2.24E+01 60.01 1.22 -9.79E-03 2.32E-01 86.55 30.70 7.70E-02 2.39E-01 105.31 21.10 + Ra-226 7.14E-01 6.59E-01 6.59E-01 186.21 3.64 Pa-231 2.72E+00 1.57E+00 2.40E+00 27.36 10.30 2.37E-01 2.13E+00 283.69 1.70 -1.35E+00 1.58E+00 300.07 2.47 -1.02E+00 1.57E+00 302.65 2.20 2.32E+00 2.89E+00 330.06 1.40 + U-235 1.12E-01 4.19E-02 3.70E-01 143.76 10.96 -2.57E-01 6.96E-01 163.33 5.08 4.54E-02 4.19E-02 185.71 57.20 -1.88E+00 3.31E+00 202.11 1.08 -1.45E+00 6.85E-01 205.31 5.01 Am-241 8.58E-02 7.61E-01 7.61E-01 59.54 35.90

+ 
= Nuclide identified during the nuclide identification Energy line found in the spectrum
= 
= MDA value not calculated Half-life too short to be able to perform the decay correction
= 
? 
= CAUTION: MDA value is inconsistent with Currie MDA at 95% confidence level

8:37:22AM 8/15/2019 Page 1 of 7 L1-12203B-VJGS-003SS 15-Aug-19-10018 Analysis Report for GAMMA SPECTRUM ANALYSIS Sample Description Sample Identification 15-Aug-19-10018 L1-12203B-VJGS-003SS Sample Type Soil Unit Sample Point Sample Size Peak Locate Threshold Peak Locate Range (in channels) Peak Area Range (in channels) Identification Energy Tolerance Sample Taken On Acquisition Started Live Time Real Time Energy Calibration Used Done On Efficiency Calibration Used Done On 1.467E+03 grams 1.000 keV 120 - 4096 120 - 4096 Detector Name 900.4 seconds 900.0 seconds 9/29/2018 8/15/2019 324 8/1/2019 1:28:00PM 8/15/2019 8:22:08AM Dead Time Efficiency Calibration Description 0.04 % Sample Number

78810 Facility Procedure Default 130G_SOIL_1 Administrator Operator 3.00 Geometry 130G_SOIL_1 Fill Height 1467.17 gram Certificate Name Certificate Date Eu155-Na22 1/30/2013 12:00:00PM 120 4096 Peak Analysis To Channel Peak Analysis From Channel Peak Analysis Performed on PEAK ANALYSIS REPORT 8/15/2019 8:37:11AM

~~~pex-Gamma

Page 2 of 7 8/15/2019 8:37:22AM Analysis Report for L1-12203B-VJGS-003SS 15-Aug-19-10018 Peak No. ROI start ROI end (keV) Energy FWHM (keV) Counts Continuum Uncertainty Net Area Area Net Peak Peak Centroid 1 20.79 6.98E+01 158 1.75E+02 151 155.00 77.20 0.61 2 38.96 2.29E+02 487 9.60E+01 M 473 477.51 238.66 1.17 3 12.85 6.06E+01 487 7.16E+01 m 473 483.41 241.62 1.17 4 16.10 9.24E+01 594 7.36E+01 585 590.10 295.02 1.18 5 14.51 5.09E+01 681 6.71E+01 671 676.35 338.19 1.29 6 14.84 1.12E+02 708 5.04E+01 700 703.62 351.84 1.23 7 8.90 2.40E+01 959 2.50E+01 951 955.20 477.73 0.96 8 13.17 8.64E+01 1171 3.46E+01 1160 1165.72 583.06 1.18 9 12.42 1.20E+02 1223 1.35E+01 1212 1217.77 609.10 1.22 10 10.07 6.36E+01 1827 1.54E+01 1817 1821.27 910.91 1.76 11 9.80 2.55E+01 1943 2.75E+01 1932 1937.22 968.88 0.81 12 21.67 4.41E+02 2928 1.05E+01 2915 2920.82 1460.39 2.02 Errors quoted at 1.000sigma M = First peak in a multiplet region m = Other peak in a multiplet region F = Fitted singlet No background subtract performed on this spectrum. NUCLIDE IDENTIFICATION REPORT Nuclide Library Used C:\\Canberra\\Apex\\Root\\Default\\Library\\ZION LIB-BNL.NLB IDENTIFIED NUCLIDES Id Yield(%) Activity (pCi/grams) Activity Nuclide Name Confidence (keV) Energy Uncertainty 2.67E-01 1.01E-01 BE-7 0.99 10.44 477.60 8.38E+00 5.50E-01 K-40 0.97 10.66 1460.82 1.12E-01 1.84E-02 Tl-208 0.99 85.00 583.19 Pb-212 1.00 0.60 115.18 3.24E-01 6.09E-02 43.60 238.63

Page 3 of 7 8/15/2019 8:37:22AM Analysis Report for L1-12203B-VJGS-003SS 15-Aug-19-10018 Id Yield(%) Activity (pCi/grams) Activity Nuclide Name Confidence (keV) Energy Uncertainty 3.30 300.09 Pb-212 1.00 Pb212-XR 0.99 10.28 74.82 4.58E-01 1.44E-01 17.10 77.11 3.97 87.35 1.46 89.78 3.02E-01 3.60E-02 Bi-214 0.99 45.49 609.32 4.89 768.36 1.26 806.18 3.11 934.06 14.92 1120.29 1.63 1155.21 5.83 1238.12 1.43 1280.98 3.99 1377.67 0.79 1385.31 1.33 1401.52 2.39 1407.99 2.13 1509.21 1.05 1661.27 2.88 1729.59 15.30 1764.49 2.03 1847.43 1.16 2118.51 5.18E-01 1.17E-01 Pb-214 0.99 7.25 241.99 3.49E-01 6.68E-02 18.42 295.22 2.47E-01 3.83E-02 35.60 351.93 1.06 785.96 Pb214-XR 0.99 5.80 74.82 8.07E-01 2.57E-01 9.70 77.11 2.24 87.35 0.82 89.78 Ac-228 0.99 2.42 129.07 3.89 209.25 3.46 270.24 2.95 328.00 3.45E-01 1.02E-01 11.27 338.32 1.92 409.46 4.40 463.00 4.25 794.95 3.66E-01 6.01E-02 25.80 911.20 4.99 964.77 2.50E-01 9.64E-02 15.80 968.97 3.22 1588.20 = Energy line found in the spectrum. Nuclide confidence index threshold = 0.30 Errors quoted at 1.000sigma Energy Tolerance : 1.000 keV = Energy line not used for Weighted Mean Activity = Manually added nuclide. = Manually edited nuclide. ?

Page 4 of 7 8/15/2019 8:37:22AM Analysis Report for L1-12203B-VJGS-003SS 15-Aug-19-10018 INTERFERENCE CORRECTED REPORT Nuclide Name Nuclide (pCi/grams) Wt mean Activity Comments Confidence Wt mean Activity Uncertainty Id 2.67E-01 1.01E-01 BE-7 0.997 8.38E+00 5.50E-01 K-40 0.970 1.12E-01 1.84E-02 Tl-208 0.997 X Bi-211 0.910 3.24E-01 6.09E-02 Pb-212 1.000 4.58E-01 1.44E-01 ? Pb212-XR 0.999 3.02E-01 3.60E-02 Bi-214 0.997 2.90E-01 3.20E-02 Pb-214 0.995 8.07E-01 2.57E-01 ? Pb214-XR 0.999 3.36E-01 4.57E-02 Ac-228 0.995 Errors quoted at 1.000sigma nuclide contains energy lines not used in Weighted Mean Activity = X = nuclide rejected by the interference analysis nuclide is part of an undetermined solution =

? 

Page 5 of 7 8/15/2019 8:37:22AM Analysis Report for L1-12203B-VJGS-003SS 15-Aug-19-10018 UNIDENTIFIED PEAKS Peak Locate Performed on Peak Locate From Channel Peak Locate To Channel 8/15/2019 8:37:11AM 4096 120 Peak No. Energy (keV) Peak Size (CPS) Peak CPS (%) Uncertainty Peak Type Tolerance Nuclide All peaks were identified. Errors quoted at 1.000sigma F = Fitted singlet m = Other peak in a multiplet region M = First peak in a multiplet region

C:\\Canberra\\Apex\\Root\\Default\\Library\\ZION LIB-BNL.NLB Nuclide Library Used NUCLIDE MDA REPORT Line MDA (pCi/grams)

Yield(%) Nuclide Name Nuclide MDA (pCi/grams) Activity (pCi/grams) (keV) Energy An Pk 8.99E-02 6.51E-02 6.51E-02 511.00 100.00 + BE-7 2.67E-01 3.13E-01 3.13E-01 477.60 10.44 + K-40 8.38E+00 4.04E-01 4.04E-01 1460.82 10.66 Mn-54 -1.13E-02 4.27E-02 4.27E-02 834.85 99.98 Co-60 1.94E-02 5.55E-02 6.40E-02 1173.23 99.85 3.17E-03 5.55E-02 1332.49 99.98 Nb-94 -3.16E-02 3.65E-02 3.65E-02 702.65 99.81 5.76E-03 3.73E-02 871.09 99.89 Ag-108m -2.48E-01 3.52E-02 1.22E+00 79.13 6.60 -2.62E-02 3.52E-02 433.94 90.50 -4.06E-02 5.34E-02 614.28 89.80 -9.90E-03 4.92E-02 722.94 90.80 Sb-125 2.53E-01 1.32E-01 5.74E-01 176.31 6.84 4.59E-01 2.39E+00 380.45 1.52 9.19E-02 1.32E-01 427.87 29.60 1.73E-01 3.99E-01 463.36 10.49 7.58E-02 2.29E-01 600.60 17.65 -1.76E-01 1.39E+00 606.71 4.98 1.20E-01 3.58E-01 635.95 11.22

Page 6 of 7 8/15/2019 8:37:22AM Analysis Report for L1-12203B-VJGS-003SS 15-Aug-19-10018 Line MDA (pCi/grams) Yield(%) Nuclide Name Nuclide MDA (pCi/grams) Activity (pCi/grams) (keV) Energy 4.85E-01 2.35E+00 671.44 1.79 Sb-125 1.32E-01 Ba-133 -1.10E+00 7.62E-02 2.87E+00 79.61 2.65 -2.20E-01 1.88E-01 81.00 32.90 3.53E-02 4.83E-01 276.40 7.16 4.82E-02 2.05E-01 302.85 18.34 -3.00E-02 7.62E-02 356.01 62.05 -1.10E-02 3.90E-01 383.85 8.94 Cs-134 -3.12E-01 5.40E-02 2.91E+00 475.36 1.48 -8.09E-02 4.79E-01 563.25 8.34 -9.59E-02 2.41E-01 569.33 15.37 -7.05E-03 6.41E-02 604.72 97.62 1.00E-02 5.40E-02 795.86 85.46 -1.23E-01 4.97E-01 801.95 8.69 1.53E+00 5.36E+00 1038.61 0.99 2.46E-03 3.62E+00 1167.97 1.79 2.04E-01 1.54E+00 1365.19 3.02 Cs-137 3.29E-02 6.74E-02 6.74E-02 661.66 85.10 Eu-152 -2.43E-02 1.26E-01 1.26E-01 121.78 28.67 -2.70E-01 5.04E-01 244.70 7.61 -2.73E+00 1.07E+01 295.94 0.45 -8.13E-02 1.26E-01 344.28 26.60 -1.63E+00 3.95E+00 367.79 0.86 5.58E-02 1.58E+00 411.12 2.24 -6.23E-01 1.15E+00 443.96 2.83 -2.24E+00 8.49E+00 488.68 0.42 -1.04E+00 7.98E+00 563.99 0.49 9.93E-02 1.43E+01 586.26 0.46 -1.44E-02 8.22E+00 678.62 0.47 -1.20E+00 4.56E+00 688.67 0.86 -3.99E+00 1.41E+01 719.35 0.28 -1.99E-01 2.97E-01 778.90 12.96 9.55E-01 1.34E+01 810.45 0.32 -5.36E-01 8.90E-01 867.37 4.26 4.55E-01 1.00E+01 919.33 0.43 1.51E-02 4.15E-01 964.08 14.65 -7.49E-02 4.52E-01 1085.87 10.24 3.50E-01 2.97E+00 1089.74 1.73 -3.72E-01 4.37E-01 1112.07 13.69 -2.38E+00 4.01E+00 1212.95 1.43 -2.33E+01 2.97E+01 1249.94 0.19 6.03E-01 3.03E+00 1299.14 1.63 1.09E-01 2.18E-01 1408.01 21.07 -2.00E+01 4.25E+01 1457.64 0.50 -1.84E+00 1.16E+01 1528.10 0.28 Eu-154 -2.98E-02 8.59E-02 8.59E-02 123.07 40.40 1.62E-01 4.77E-01 247.93 6.89 -1.30E-01 8.02E-01 591.76 4.95 3.06E-01 2.32E+00 692.42 1.78 7.46E-02 2.32E-01 723.30 20.06 3.92E-01 9.11E-01 756.80 4.52 4.79E-02 3.10E-01 873.18 12.08

Page 7 of 7 8/15/2019 8:37:22AM Analysis Report for L1-12203B-VJGS-003SS 15-Aug-19-10018 Line MDA (pCi/grams) Yield(%) Nuclide Name Nuclide MDA (pCi/grams) Activity (pCi/grams) (keV) Energy 1.51E-01 4.45E-01 996.29 10.48 Eu-154 8.59E-02 -5.14E-02 2.45E-01 1004.76 18.01 6.89E-02 1.72E-01 1274.43 34.80 2.90E-01 1.65E+00 1596.48 1.80 Eu-155 -1.14E-02 1.91E-01 1.23E+01 45.30 1.31 -4.47E+00 1.26E+01 60.01 1.22 -3.34E-02 1.91E-01 86.55 30.70 5.25E-02 2.07E-01 105.31 21.10 Ra-226 9.34E-01 1.14E+00 1.14E+00 186.21 3.64 Pa-231 1.32E+00 1.40E+00 1.40E+00 27.36 10.30 2.44E-01 1.97E+00 283.69 1.70 -8.37E-01 1.55E+00 300.07 2.47 4.01E-01 1.70E+00 302.65 2.20 1.88E+00 2.84E+00 330.06 1.40 U-235 1.65E-01 7.35E-02 3.21E-01 143.76 10.96 1.32E-02 7.35E-01 163.33 5.08 6.97E-02 7.35E-02 185.71 57.20 -2.84E-01 3.40E+00 202.11 1.08 -3.35E-01 7.09E-01 205.31 5.01 Am-241 -1.19E-01 4.41E-01 4.41E-01 59.54 35.90

+ 
= Nuclide identified during the nuclide identification Energy line found in the spectrum
= 
= MDA value not calculated Half-life too short to be able to perform the decay correction
= 
? 
= CAUTION: MDA value is inconsistent with Currie MDA at 95% confidence level FSS AREA ACCESS REQUEST, AUTHORIZATION AND SIGN-IN SHEET REQUEST FOR ACCESS:

ZS-LT-300-001-003 Revision 6 Information Use Survey Area No.: 12000 Survey Unit No.: 12203C Survey Unit Type: Open Land [8J Structure D System D Work Group

Contact:

Final Status Survey (FSS), supervisor Radio RP-3. Description of Planned Activities: This is the I st Bi-annual surveillance survey for this survey unit. Duration: Start 8/1/19 Stop 8/1/19 Access Controls Required:

1. All personnel will brief and sign in/out on this FSS Attachment 2.
2. All personnel and equipment will be surveyed into the area by the FSS technician.
3. There will be a minimum of one scheduled biased surface soil sample taken in this survey unit.
4. When job is completed, the survey unit postings will be verified saf ctory.

/ ~ Approt:' "I. \\ )vJ ~ Survey Name Time Time Unit# (Print/Sign) In Out 12203C Karen Nicholson/ KU\\t FSS technician 8-1-19

n. 3Ss ) 1./: I 5

}d, d O 3 C. \\'Y\\~-r: ~-!-J ~ J'3.35r J'1:J5 / (k;i,.,~,:.e,- S.. \\,f'f' iH2J-11-1P, r ~.~r-er Svpqc.-t ~-)-j ~

13. 3~ J LJ: IS ZS-L T-300-001-003 Revision 6 Information Use FSS I&C Surveillance Summary AREA SURVEILLANCE:

Survey Area No.: 12000 Survey Unit No.: 12203C

== Description:== Performing 1st Bi-Annual surveillance survey. Survey Unit Type: Structure D Classification: OpenLand!ZI Class 3 D Class2 D Class 1 ~ Reason for Surveillance: Semi-Annual IZI Special D System Surveillance Due Date: 7-10-19 Reason: Bi-annual Surveillance survey. (Survey Date surveillance performed: 8-1-19 performed after due date because the storage and removal of the CCDD pile in the adjacent survey area 12205). SURVEILLANCE ACTIVITIES:

1) Review ZS-LT-300-001-003 Attachment 2, FSS Area Access Request, Authorization and Sign-In Sheet for authorized entries into the FSS Survey Unit*--*-----------------------------------------------------------------------------------------* IZ!
2) Perform a walk down of the FSS Survey Unit and identify decommissioning activities adjacent survey units that could have a reasonable potential to spread radioactive material to the FSS Survey Unit--------*------- IZ!

SURVEILLANCE COMMENTS AND OBSERVATIONS: The CCDD is now removed, and the surveillance survey is being performed. The FSS technician and the MBI laborer (RD, AV) support walked down the survey unit and selected sample location. Informed the MBI foreman (N.Friant). 13:38 The FSS technician signed the group in, and surveyed all the sampling equipment into the survey unit. 13:52 Collected biased surface soil sample #Ll 12203CVJGS001SS.

== Description:== medium brown sand, and gravel. Location selected at a dried, low water area. 14:15 Completed surveillance in this survey unit. The group signed out of the survey unit. The collected sample was brought to the sample prep trailer for processing. Notes: The sample location was GPS'd, and the corrected coordinate with the location will be shown on the attached map. There were some small pieces of metal, and old flags that were surveyed and removed from the survey unit. The postings were satisfactory. The postings are represented on the adjacent FSS survey units. A Model 3 #283228 with a 44-9/PR355606, cal due 1-12-20 was used for all the surveying. All survey results were indistinguishable from background. Back ound 30-50 cpm. IZ!- Surveillance Satisfactory D-Surveillance Un-Satisfactory 15:30 (Time) /( 'Z-V (Time) (Time)

343680 343710 343740 0 N co,.. ;z '*7 ~---~-:~~:* ~ .. :~~- ~---, ;-----..c~*

r~ ~-*

~ . ---~-__

-~---~~---

-==--~----; .\\

  • --------~------.,__.,;::.. __

Legend N A 40 Ftet Final Status Survey Surveillance 12203C NAD83 IL State Plane East 1201 {Meters) 2017 Aerials - Lake County G/S Dept D Survey Unit (SU) 12203C [,. 0 Biased Surface Sample Date performed: 08/01/2019 Drawing: FSS SURV 080119 ~~--'- - ~i-..:.- ~ i ----~'-- ------- ---- j

8:37:29AM 8/15/2019 Page 1 of 7 L1-12203C-VJGS-001SS 15-Aug-19-10019 Analysis Report for GAMMA SPECTRUM ANALYSIS Sample Description Sample Identification 15-Aug-19-10019 L1-12203C-VJGS-001SS Sample Type Soil Unit Sample Point Sample Size Peak Locate Threshold Peak Locate Range (in channels) Peak Area Range (in channels) Identification Energy Tolerance Sample Taken On Acquisition Started Live Time Real Time Energy Calibration Used Done On Efficiency Calibration Used Done On 1.581E+03 grams 1.000 keV 120 - 8192 120 - 8192 Detector Name 900.3 seconds 900.0 seconds 9/29/2018 8/15/2019 352 8/1/2019 1:52:00PM 8/15/2019 8:22:16AM Dead Time Efficiency Calibration Description 0.04 % Sample Number

78811 Facility Procedure Default 130G_SOIL_1 Administrator Operator 3.00 Geometry 130G_SOIL_1 Fill Height 1581.07 gram Certificate Name Certificate Date Eu155-Na22 1/7/2013 12:00:00PM 120 8192 Peak Analysis To Channel Peak Analysis From Channel Peak Analysis Performed on PEAK ANALYSIS REPORT 8/15/2019 8:37:19AM

~~~pex-Gamma

Page 2 of 7 8/15/2019 8:37:29AM Analysis Report for L1-12203C-VJGS-001SS 15-Aug-19-10019 Peak No. ROI start ROI end (keV) Energy FWHM (keV) Counts Continuum Uncertainty Net Area Area Net Peak Peak Centroid 1 7.28 2.25E+01 314 4.41E+01 M 298 300.53 74.80 0.53 2 8.30 3.09E+01 314 5.31E+01 m 298 309.59 77.07 0.53 3 13.11 2.82E+01 748 6.38E+01 739 744.56 185.96 0.35 4 22.46 1.50E+02 961 1.13E+02 945 955.34 238.72 1.19 5 11.51 5.97E+01 1188 2.73E+01 1176 1181.08 295.22 0.76 6 9.38 1.99E+01 1316 2.61E+01 1306 1311.00 327.73 0.82 7 15.04 9.87E+01 1414 4.43E+01 1400 1407.55 351.89 0.88 8 9.84 3.02E+01 1915 2.48E+01 1903 1909.10 477.38 0.70 9 11.50 8.40E+01 2339 1.60E+01 2324 2331.84 583.13 1.07 10 11.66 8.56E+01 2444 1.64E+01 2429 2436.24 609.24 1.08 11 8.38 3.71E+01 2653 1.19E+01 2641 2646.63 661.86 0.97 12 5.56 2.04E+01 3446 3.56E+00 3435 3440.14 860.28 0.45 13 9.24 4.20E+01 3651 1.50E+01 3637 3643.75 911.18 1.33 14 6.45 1.90E+01 3882 9.00E+00 3871 3876.35 969.32 0.48 15 20.75 3.75E+02 5855 1.30E+01 5830 5843.28 1460.73 1.81 Errors quoted at 1.000sigma M = First peak in a multiplet region m = Other peak in a multiplet region F = Fitted singlet No background subtract performed on this spectrum. NUCLIDE IDENTIFICATION REPORT Nuclide Library Used C:\\Canberra\\Apex\\Root\\Default\\Library\\ZION LIB-BNL.NLB IDENTIFIED NUCLIDES Id Yield(%) Activity (pCi/grams) Activity Nuclide Name Confidence (keV) Energy Uncertainty 3.67E-01 1.22E-01 BE-7 0.99 10.44 477.60 7.78E+00 5.47E-01 K-40 0.99 10.66 1460.82

Page 3 of 7 8/15/2019 8:37:29AM Analysis Report for L1-12203C-VJGS-001SS 15-Aug-19-10019 Id Yield(%) Activity (pCi/grams) Activity Nuclide Name Confidence (keV) Energy Uncertainty 5.72E-02 1.34E-02 Cs-137 0.99 85.10 661.66 1.19E-01 1.78E-02 Tl-208 1.00 85.00 583.19 Pb-212 0.99 0.60 115.18 2.33E-01 3.97E-02 43.60 238.63 3.30 300.09 3.89E-01 1.32E-01 Pb212-XR 1.00 10.28 74.82 2.87E-01 8.27E-02 17.10 77.11 3.97 87.35 1.46 89.78 2.34E-01 3.48E-02 Bi-214 1.00 45.49 609.32 4.89 768.36 1.26 806.18 3.11 934.06 14.92 1120.29 1.63 1155.21 5.83 1238.12 1.43 1280.98 3.99 1377.67 0.79 1385.31 1.33 1401.52 2.39 1407.99 2.13 1509.21 1.05 1661.27 2.88 1729.59 15.30 1764.49 2.03 1847.43 1.16 2118.51 Pb-214 1.00 7.25 241.99 2.47E-01 5.15E-02 18.42 295.22 2.39E-01 4.11E-02 35.60 351.93 1.06 785.96 4.70E-01 2.22E-01 Ra-226 0.99 3.64 186.21 Ac-228 0.73 2.42 129.07 3.89 209.25 3.46 270.24 5.54E-01 2.65E-01 2.95 328.00 11.27 338.32 1.92 409.46 4.40 463.00 4.25 794.95 2.63E-01 5.90E-02 25.80 911.20 4.99 964.77 2.03E-01 6.93E-02 15.80 968.97 3.22 1588.20 U-235 0.99 10.96 143.76 5.08 163.33 2.99E-02 1.41E-02 57.20 185.71 1.08 202.11 5.01 205.31

Page 4 of 7 8/15/2019 8:37:29AM Analysis Report for L1-12203C-VJGS-001SS 15-Aug-19-10019 = Energy line found in the spectrum. Nuclide confidence index threshold = 0.30 Errors quoted at 1.000sigma Energy Tolerance : 1.000 keV = Energy line not used for Weighted Mean Activity = Manually added nuclide. = Manually edited nuclide. ? INTERFERENCE CORRECTED REPORT Nuclide Name Nuclide (pCi/grams) Wt mean Activity Comments Confidence Wt mean Activity Uncertainty Id 3.67E-01 1.22E-01 BE-7 0.992 7.78E+00 5.47E-01 K-40 0.999 5.72E-02 1.34E-02 Cs-137 0.993 1.19E-01 1.78E-02 Tl-208 1.000 X Bi-211 0.898 2.33E-01 3.97E-02 Pb-212 0.999 3.16E-01 7.01E-02 Pb212-XR 1.000 2.34E-01 3.48E-02 Bi-214 1.000 2.42E-01 3.21E-02 Pb-214 1.000 X Pb214-XR 1.000 4.70E-01 2.22E-01 ? Ra-226 0.990 2.47E-01 4.43E-02 Ac-228 0.736 2.99E-02 1.41E-02 ? U-235 0.993 Errors quoted at 1.000sigma nuclide contains energy lines not used in Weighted Mean Activity = X = nuclide rejected by the interference analysis nuclide is part of an undetermined solution =

? 

Page 5 of 7 8/15/2019 8:37:29AM Analysis Report for L1-12203C-VJGS-001SS 15-Aug-19-10019 UNIDENTIFIED PEAKS Peak Locate Performed on Peak Locate From Channel Peak Locate To Channel 8/15/2019 8:37:19AM 8192 120 Peak No. Energy (keV) Peak Size (CPS) Peak CPS (%) Uncertainty Peak Type Tolerance Nuclide 12 860.28 2.27083E-02 27.22 Errors quoted at 1.000sigma F = Fitted singlet m = Other peak in a multiplet region M = First peak in a multiplet region

C:\\Canberra\\Apex\\Root\\Default\\Library\\ZION LIB-BNL.NLB Nuclide Library Used NUCLIDE MDA REPORT Line MDA (pCi/grams)

Yield(%) Nuclide Name Nuclide MDA (pCi/grams) Activity (pCi/grams) (keV) Energy An Pk 9.97E-02 6.92E-02 6.92E-02 511.00 100.00 + BE-7 3.67E-01 3.71E-01 3.71E-01 477.60 10.44 + K-40 7.78E+00 5.85E-01 5.85E-01 1460.82 10.66 Mn-54 1.64E-02 5.23E-02 5.23E-02 834.85 99.98 Co-60 4.29E-02 5.96E-02 7.42E-02 1173.23 99.85 6.02E-02 5.96E-02 1332.49 99.98 Nb-94 -8.36E-03 4.58E-02 4.79E-02 702.65 99.81 -4.18E-02 4.58E-02 871.09 99.89 Ag-108m -3.48E-01 4.63E-02 1.64E+00 79.13 6.60 3.77E-02 4.63E-02 433.94 90.50 3.39E-03 7.74E-02 614.28 89.80 -4.47E-03 5.63E-02 722.94 90.80 Sb-125 -1.63E-01 1.27E-01 5.45E-01 176.31 6.84 1.59E+00 2.69E+00 380.45 1.52 4.23E-02 1.27E-01 427.87 29.60 3.35E-01 4.36E-01 463.36 10.49 -2.18E-01 2.49E-01 600.60 17.65 2.72E+00 1.49E+00 606.71 4.98

Page 6 of 7 8/15/2019 8:37:29AM Analysis Report for L1-12203C-VJGS-001SS 15-Aug-19-10019 Line MDA (pCi/grams) Yield(%) Nuclide Name Nuclide MDA (pCi/grams) Activity (pCi/grams) (keV) Energy -1.85E-01 4.27E-01 635.95 11.22 Sb-125 1.27E-01 2.64E-02 2.14E+00 671.44 1.79 Ba-133 -2.53E+00 8.67E-02 3.97E+00 79.61 2.65 -1.11E-01 2.82E-01 81.00 32.90 -2.88E-02 5.21E-01 276.40 7.16 8.45E-02 2.23E-01 302.85 18.34 -1.73E-02 8.67E-02 356.01 62.05 -2.51E-01 4.01E-01 383.85 8.94 Cs-134 1.08E+00 6.09E-02 3.63E+00 475.36 1.48 -2.99E-02 4.92E-01 563.25 8.34 -6.89E-02 2.69E-01 569.33 15.37 -1.47E-02 7.16E-02 604.72 97.62 3.60E-02 6.09E-02 795.86 85.46 -6.24E-01 4.98E-01 801.95 8.69 -3.24E+00 5.01E+00 1038.61 0.99 3.06E-01 3.84E+00 1167.97 1.79 1.27E+00 1.64E+00 1365.19 3.02 + Cs-137 5.72E-02 3.45E-02 3.45E-02 661.66 85.10 Eu-152 -4.37E-03 1.41E-01 1.56E-01 121.78 28.67 2.61E-01 5.99E-01 244.70 7.61 7.68E+00 1.04E+01 295.94 0.45 -1.98E-01 1.41E-01 344.28 26.60 -2.69E+00 4.50E+00 367.79 0.86 1.00E+00 1.81E+00 411.12 2.24 -2.64E-01 1.31E+00 443.96 2.83 3.97E+00 1.04E+01 488.68 0.42 7.68E+00 8.62E+00 563.99 0.49 -2.78E+00 1.51E+01 586.26 0.46 -1.55E+00 8.12E+00 678.62 0.47 2.90E+00 5.27E+00 688.67 0.86 1.06E+01 1.61E+01 719.35 0.28 -1.54E-01 3.57E-01 778.90 12.96 7.13E+00 1.30E+01 810.45 0.32 -1.29E-01 1.12E+00 867.37 4.26 -4.10E+00 1.18E+01 919.33 0.43 -2.33E-01 4.63E-01 964.08 14.65 2.57E-01 5.39E-01 1085.87 10.24 2.02E-01 3.45E+00 1089.74 1.73 -7.51E-01 4.42E-01 1112.07 13.69 -1.10E+00 4.79E+00 1212.95 1.43 1.68E+01 3.41E+01 1249.94 0.19 -3.21E+00 3.54E+00 1299.14 1.63 -4.17E-02 2.32E-01 1408.01 21.07 1.69E+02 4.32E+01 1457.64 0.50 4.88E+00 1.19E+01 1528.10 0.28 Eu-154 1.66E-02 1.10E-01 1.10E-01 123.07 40.40 6.58E-02 5.50E-01 247.93 6.89 -3.18E-01 8.92E-01 591.76 4.95 1.41E+00 2.59E+00 692.42 1.78 -2.83E-02 2.58E-01 723.30 20.06 6.28E-02 9.80E-01 756.80 4.52

Page 7 of 7 8/15/2019 8:37:29AM Analysis Report for L1-12203C-VJGS-001SS 15-Aug-19-10019 Line MDA (pCi/grams) Yield(%) Nuclide Name Nuclide MDA (pCi/grams) Activity (pCi/grams) (keV) Energy -5.81E-02 3.97E-01 873.18 12.08 Eu-154 1.10E-01 -1.06E-01 4.41E-01 996.29 10.48 -9.19E-02 2.44E-01 1004.76 18.01 2.41E-02 1.66E-01 1274.43 34.80 1.60E+00 2.99E+00 1596.48 1.80 Eu-155 3.71E+00 2.42E-01 2.30E+01 45.30 1.31 1.50E+01 2.69E+01 60.01 1.22 -1.59E-01 2.42E-01 86.55 30.70 1.32E-01 2.51E-01 105.31 21.10 + Ra-226 4.70E-01 7.25E-01 7.25E-01 186.21 3.64 Pa-231 2.70E+00 1.66E+00 2.53E+00 27.36 10.30 -1.48E+00 2.20E+00 283.69 1.70 2.95E-01 1.66E+00 300.07 2.47 1.05E+00 1.87E+00 302.65 2.20 1.07E+00 3.03E+00 330.06 1.40 + U-235 5.25E-02 4.62E-02 3.91E-01 143.76 10.96 4.33E-01 7.91E-01 163.33 5.08 2.99E-02 4.62E-02 185.71 57.20 -5.79E-02 3.45E+00 202.11 1.08 -4.90E-01 7.62E-01 205.31 5.01 Am-241 4.63E-01 9.47E-01 9.47E-01 59.54 35.90

+ 
= Nuclide identified during the nuclide identification Energy line found in the spectrum
= 
= MDA value not calculated Half-life too short to be able to perform the decay correction
= 
? 
= CAUTION: MDA value is inconsistent with Currie MDA at 95% confidence level FSS AREA ACCESS REQUEST, AUTHORIZATION AND SIGN-IN SHEET REQUEST FOR ACCESS:

ZS-LT-300-001-003 Revision 6 Information Use Survey Area No.: 12000 Survey Unit No.: 12203D Survey Unit Type: Open Land IZI Structure D System D Work Group

Contact:

Final Status Survey (FSS), supervisor Radio RP-3. Description of Planned Activities: This is the 1st Bi-annual surveillance survey for this survey unit. Duration: Start 8/1/19 Stop 8/1/19 Access Controls Required:

1. All personnel will brief and sign in/out on this FSS Attachment 2.
2. All personnel and equipment will be surveyed into the area by the FSS technician.
3. There will be a minimum of one scheduled biased surface soil sample taken in this survey unit.
4. When job is completed, the survey unit postings will be verified a isfa~

Survey Unit# 12203D

  • -~---

Name (Print/Sign) / ~"JJvvtA----- Approvf!ci by: __ at _ ___,, __________ _ Time Time In Out FSS technician 8-1-19 i V'.15- /y;y5 h18.r J.. ~o,--~r-S-0pflv,t- ~ !**19 /v. I c; ;\\,:-y5 mB ~ L,v-6 o,-"'1-5 VfFO, f ~ -J-l (.1 /lf./ 5 ilf: ys Page / of 3 FSS l&C Surveillance Summary AREA SURVEILLANCE: Survey Area No.: 12000 Survey Unit No.:

== Description:== Performing 1st Bi-Annual surveillance survey. Survey Unit Type: Structure D ZS-LT-300-001-003 Revision 6 Information Use 12203D System O Classification: Open Land IZI Class 3 D Class 2 D Class 1 IZI Reason for Surveillance: Semi-Annual IZI Special D Surveillance Due Date: 7-10-19 Reason: Bi-annual Surveillance survey. (Survey Date surveillance performed: 8-1-19 performed after due date because the storage and removal of the CCDD pile in the adjacent survey area 12205). SURVEILLANCE ACTIVITIES:

1) Review ZS-LT-300-001-003 Attachment 2, FSS Area Access Request, Authorization and Sign-In Sheet for authorized entries into the FSS Survey Unit**************-**-**-***-**---****-****--*--*--*****----*-**-*---* --*--*---------*---------** 1::8'.1
2) Perform a walk down of the FSS Survey Unit and identify decommissioning activities adjacent survey units that could have a reasonable potential to spread radioactive material to the FSS Survey Unit.-*---*-**------*

1::8'.1 SURVEILLANCE COMMENTS AND OBSERVATIONS: The CCDD is now removed, and the surveillance survey is being performed. The FSS technician and the MBI laborer (RD, AV) support walked down the survey unit and selected sample location. Informed the MBI foreman (N.Friant). 14: 15 The FSS technician signed the group in, and surveyed all the sampling equipment into the survey unit. 14:33 Collected biased surface soil sample #Ll 12203DVJGS001SS.

== Description:== medium brown sand, and gravel. Location selected at dried, low point in soil. 14:45 Completed surveillance in this survey unit. The group signed out of the survey unit. The collected sample was brought to the sample prep trailer for processing. Notes: The sample location was GPS'd, and the corrected coordinate with the location will be shown on the attached map. There were some small pieces of metal, water bottle, plastic at fence line, and old flags that were surveyed and removed from the survey unit. The postings were satisfactory. The postings are represented on the adjacent FSS survey units. A Model 3 #283228 with a 44-9/PR355606, cal due 1-12-20 was used for all the surveying. All survey results were indistinguishable from background. Back ound 30-50 cpm. aren 1c o so :

  • Ch.C,11\\ /Lil cl~:).(.

9-4-19 15:45 (Print Name/Signature) C/L (1rj_ tu~ (Date) (Time) -i-,q P43 (Print Name/Signature) Radio J).'v,Jcu ~Dv-J I (Print Name/Signature) C/LT Manag /Date) (Time) II '26 JC/ 0'?38' (Date) (Time)

343710 343740 0 ~ ~ 0 I() <.D ~ 0 fR ~ Legend D Survey Unit (SU} 12203D 0 Biased Surface Sample 343770 Final Status Survey Surveillance 12203D NADB3 IL State Plane East 1201 (Meters) 2017 Aerials

  • Lake COi.iniy GIS Dept.

Date performed: 08/05/2019 Drawing: FSS SURV12203D 081519

9:03:52AM 8/15/2019 Page 1 of 7 L1-12203D-VJGS-001SS 15-Aug-19-10020 Analysis Report for GAMMA SPECTRUM ANALYSIS Sample Description Sample Identification 15-Aug-19-10020 L1-12203D-VJGS-001SS Sample Type Soil Unit Sample Point Sample Size Peak Locate Threshold Peak Locate Range (in channels) Peak Area Range (in channels) Identification Energy Tolerance Sample Taken On Acquisition Started Live Time Real Time Energy Calibration Used Done On Efficiency Calibration Used Done On 1.352E+03 grams 1.000 keV 120 - 4096 120 - 4096 Detector Name 900.3 seconds 900.0 seconds 9/29/2018 8/15/2019 324 8/1/2019 2:33:00PM 8/15/2019 8:48:42AM Dead Time Efficiency Calibration Description 0.04 % Sample Number

78812 Facility Procedure Default 130G_SOIL_1 Administrator Operator 3.00 Geometry 130G_SOIL_1 Fill Height 1351.93 gram Certificate Name Certificate Date Eu155-Na22 1/30/2013 12:00:00PM 120 4096 Peak Analysis To Channel Peak Analysis From Channel Peak Analysis Performed on PEAK ANALYSIS REPORT 8/15/2019 9:03:44AM

~~~pex-Gamma

Page 2 of 7 8/15/2019 9:03:52AM Analysis Report for L1-12203D-VJGS-001SS 15-Aug-19-10020 Peak No. ROI start ROI end (keV) Energy FWHM (keV) Counts Continuum Uncertainty Net Area Area Net Peak Peak Centroid 1 20.47 1.48E+02 481 1.24E+02 473 477.47 238.64 1.10 2 12.15 2.66E+01 681 5.34E+01 672 676.37 338.20 0.71 3 14.27 1.43E+02 708 2.69E+01 699 703.45 351.75 1.28 4 11.19 4.80E+01 1170 3.40E+01 1161 1166.24 583.32 1.18 5 12.53 1.05E+02 1223 2.18E+01 1213 1218.00 609.21 1.05 6 9.03 3.38E+01 1825 2.12E+01 1816 1821.85 911.20 1.49 7 22.39 4.95E+02 2928 2.03E+00 2913 2921.19 1460.57 1.96 8 5.84 2.85E+01 3533 2.50E+00 3524 3528.43 1763.79 1.26 Errors quoted at 1.000sigma M = First peak in a multiplet region m = Other peak in a multiplet region F = Fitted singlet No background subtract performed on this spectrum. NUCLIDE IDENTIFICATION REPORT Nuclide Library Used C:\\Canberra\\Apex\\Root\\Default\\Library\\ZION LIB-BNL.NLB IDENTIFIED NUCLIDES Id Yield(%) Activity (pCi/grams) Activity Nuclide Name Confidence (keV) Energy Uncertainty 9.66E+00 6.06E-01 K-40 0.99 10.66 1460.82 6.39E-02 1.54E-02 Tl-208 0.99 85.00 583.19 8.81E-01 1.13E-01 Bi-211 0.92 13.02 351.07 Pb-212 1.00 0.60 115.18 2.13E-01 3.41E-02 43.60 238.63 3.30 300.09 2.69E-01 3.59E-02 Bi-214 0.98 45.49 609.32 4.89 768.36 1.26 806.18

Page 3 of 7 8/15/2019 9:03:52AM Analysis Report for L1-12203D-VJGS-001SS 15-Aug-19-10020 Id Yield(%) Activity (pCi/grams) Activity Nuclide Name Confidence (keV) Energy Uncertainty 3.11 934.06 Bi-214 0.98 14.92 1120.29 1.63 1155.21 5.83 1238.12 1.43 1280.98 3.99 1377.67 0.79 1385.31 1.33 1401.52 2.39 1407.99 2.13 1509.21 1.05 1661.27 2.88 1729.59 4.47E-01 9.34E-02 15.30 1764.49 2.03 1847.43 1.16 2118.51 Pb-214 0.51 7.25 241.99 18.42 295.22 3.22E-01 4.12E-02 35.60 351.93 1.06 785.96 Ac-228 1.00 2.42 129.07 3.89 209.25 3.46 270.24 2.95 328.00 1.84E-01 8.54E-02 11.27 338.32 1.92 409.46 4.40 463.00 4.25 794.95 1.99E-01 5.39E-02 25.80 911.20 4.99 964.77 15.80 968.97 3.22 1588.20 = Energy line found in the spectrum. Nuclide confidence index threshold = 0.30 Errors quoted at 1.000sigma Energy Tolerance : 1.000 keV = Energy line not used for Weighted Mean Activity = Manually added nuclide. = Manually edited nuclide. ? INTERFERENCE CORRECTED REPORT

Page 4 of 7 8/15/2019 9:03:52AM Analysis Report for L1-12203D-VJGS-001SS 15-Aug-19-10020 Nuclide Name Nuclide (pCi/grams) Wt mean Activity Comments Confidence Wt mean Activity Uncertainty Id 9.66E+00 6.06E-01 K-40 0.990 6.39E-02 1.54E-02 Tl-208 0.997 8.81E-01 1.13E-01 ? Bi-211 0.928 2.13E-01 3.41E-02 Pb-212 1.000 2.92E-01 3.35E-02 Bi-214 0.988 3.22E-01 4.12E-02 ? Pb-214 0.510 1.95E-01 4.56E-02 Ac-228 1.000 Errors quoted at 1.000sigma nuclide contains energy lines not used in Weighted Mean Activity = X = nuclide rejected by the interference analysis nuclide is part of an undetermined solution =

? 

Page 5 of 7 8/15/2019 9:03:52AM Analysis Report for L1-12203D-VJGS-001SS 15-Aug-19-10020 UNIDENTIFIED PEAKS Peak Locate Performed on Peak Locate From Channel Peak Locate To Channel 8/15/2019 9:03:44AM 4096 120 Peak No. Energy (keV) Peak Size (CPS) Peak CPS (%) Uncertainty Peak Type Tolerance Nuclide All peaks were identified. Errors quoted at 1.000sigma F = Fitted singlet m = Other peak in a multiplet region M = First peak in a multiplet region

C:\\Canberra\\Apex\\Root\\Default\\Library\\ZION LIB-BNL.NLB Nuclide Library Used NUCLIDE MDA REPORT Line MDA (pCi/grams)

Yield(%) Nuclide Name Nuclide MDA (pCi/grams) Activity (pCi/grams) (keV) Energy An Pk 1.11E-01 6.52E-02 6.52E-02 511.00 100.00 BE-7 4.30E-01 5.31E-01 5.31E-01 477.60 10.44 + K-40 9.66E+00 2.21E-01 2.21E-01 1460.82 10.66 Mn-54 -1.13E-02 3.97E-02 3.97E-02 834.85 99.98 Co-60 4.14E-03 5.43E-02 6.05E-02 1173.23 99.85 2.31E-02 5.43E-02 1332.49 99.98 Nb-94 3.52E-03 4.06E-02 4.06E-02 702.65 99.81 -1.64E-03 4.23E-02 871.09 99.89 Ag-108m 1.05E+00 3.87E-02 1.23E+00 79.13 6.60 2.13E-04 3.87E-02 433.94 90.50 -1.94E-02 6.00E-02 614.28 89.80 -5.14E-03 4.66E-02 722.94 90.80 Sb-125 2.09E-01 1.06E-01 5.71E-01 176.31 6.84 -4.36E-01 2.47E+00 380.45 1.52 -1.49E-02 1.06E-01 427.87 29.60 1.91E-01 3.40E-01 463.36 10.49 7.54E-02 2.29E-01 600.60 17.65 -3.40E-01 1.41E+00 606.71 4.98 -1.75E-01 3.41E-01 635.95 11.22

Page 6 of 7 8/15/2019 9:03:52AM Analysis Report for L1-12203D-VJGS-001SS 15-Aug-19-10020 Line MDA (pCi/grams) Yield(%) Nuclide Name Nuclide MDA (pCi/grams) Activity (pCi/grams) (keV) Energy -4.01E-01 2.22E+00 671.44 1.79 Sb-125 1.06E-01 Ba-133 6.53E-01 7.35E-02 2.82E+00 79.61 2.65 -3.16E-01 1.77E-01 81.00 32.90 -1.29E-01 4.66E-01 276.40 7.16 1.49E-02 1.85E-01 302.85 18.34 -4.64E-02 7.35E-02 356.01 62.05 9.41E-02 4.45E-01 383.85 8.94 Cs-134 3.19E+00 5.40E-02 3.30E+00 475.36 1.48 -2.89E-03 4.25E-01 563.25 8.34 -3.86E-02 2.26E-01 569.33 15.37 -2.05E-02 6.36E-02 604.72 97.62 3.44E-02 5.40E-02 795.86 85.46 -1.75E-01 4.74E-01 801.95 8.69 -3.98E+00 4.93E+00 1038.61 0.99 1.54E+00 3.50E+00 1167.97 1.79 5.21E-01 1.34E+00 1365.19 3.02 Cs-137 4.30E-02 5.92E-02 5.92E-02 661.66 85.10 Eu-152 2.64E-02 1.22E-01 1.22E-01 121.78 28.67 1.85E-03 4.93E-01 244.70 7.61 4.42E+00 8.82E+00 295.94 0.45 1.17E-02 1.30E-01 344.28 26.60 -2.55E-01 3.88E+00 367.79 0.86 4.70E-01 1.73E+00 411.12 2.24 -3.11E-01 1.19E+00 443.96 2.83 4.13E+00 9.21E+00 488.68 0.42 1.39E+00 7.14E+00 563.99 0.49 -5.40E+00 1.29E+01 586.26 0.46 2.40E-01 9.68E+00 678.62 0.47 1.44E+00 5.06E+00 688.67 0.86 -1.21E+00 1.34E+01 719.35 0.28 -6.70E-02 3.04E-01 778.90 12.96 2.39E+00 1.37E+01 810.45 0.32 -2.10E-02 1.01E+00 867.37 4.26 1.06E-01 1.07E+01 919.33 0.43 -1.32E-01 3.42E-01 964.08 14.65 -2.52E-01 4.71E-01 1085.87 10.24 1.57E+00 3.01E+00 1089.74 1.73 2.68E-02 4.20E-01 1112.07 13.69 3.53E-01 4.41E+00 1212.95 1.43 2.67E+00 3.05E+01 1249.94 0.19 1.59E-01 3.38E+00 1299.14 1.63 3.88E-02 2.12E-01 1408.01 21.07 -1.24E+00 4.56E+01 1457.64 0.50 -1.21E+01 1.12E+01 1528.10 0.28 Eu-154 7.55E-03 8.62E-02 8.62E-02 123.07 40.40 -1.16E-01 4.80E-01 247.93 6.89 -2.94E-01 7.86E-01 591.76 4.95 8.52E-01 2.48E+00 692.42 1.78 8.78E-02 2.29E-01 723.30 20.06 -2.47E-01 9.44E-01 756.80 4.52 -1.45E-01 3.23E-01 873.18 12.08

Page 7 of 7 8/15/2019 9:03:52AM Analysis Report for L1-12203D-VJGS-001SS 15-Aug-19-10020 Line MDA (pCi/grams) Yield(%) Nuclide Name Nuclide MDA (pCi/grams) Activity (pCi/grams) (keV) Energy -1.68E-02 4.69E-01 996.29 10.48 Eu-154 8.62E-02 1.31E-02 2.67E-01 1004.76 18.01 -4.13E-02 1.51E-01 1274.43 34.80 -1.96E+00 2.04E+00 1596.48 1.80 Eu-155 7.32E-01 1.75E-01 1.24E+01 45.30 1.31 -3.24E+00 1.32E+01 60.01 1.22 -2.09E-02 1.75E-01 86.55 30.70 1.22E-02 1.97E-01 105.31 21.10 Ra-226 5.43E-01 1.12E+00 1.12E+00 186.21 3.64 Pa-231 1.82E-01 1.10E+00 1.10E+00 27.36 10.30 -1.87E-01 1.91E+00 283.69 1.70 -1.76E+00 1.30E+00 300.07 2.47 1.24E-01 1.54E+00 302.65 2.20 1.18E+00 2.85E+00 330.06 1.40 U-235 5.34E-02 7.02E-02 3.09E-01 143.76 10.96 9.82E-02 7.33E-01 163.33 5.08 2.08E-02 7.02E-02 185.71 57.20 6.82E-01 3.62E+00 202.11 1.08 -1.76E-01 7.63E-01 205.31 5.01 Am-241 -1.78E-01 4.43E-01 4.43E-01 59.54 35.90

+ 
= Nuclide identified during the nuclide identification Energy line found in the spectrum
= 
= MDA value not calculated Half-life too short to be able to perform the decay correction
= 
? 
= CAUTION: MDA value is inconsistent with Currie MDA at 95% confidence level}}