RESRAD, Version 7.0 T1/2 Limit = 30 days 12/06/2014 16:15 Page 1 Summary : Zion Subsurface Soil 100 m^2 120614 File : C:\\RESRAD_FAMILY\\RESRAD\\7.0\\USERFILES\\ZION SUBSURFACE SOIL DCGL.RAD Table of Contents Part I: Mixture Sums and Single Radionuclide Guidelines Dose Conversion Factor (and Related) Parameter Summary... 2 Site-Specific Parameter Summary.......................... 4 Summary of Pathway Selections............................ 8 Contaminated Zone and Total Dose Summary................. 9 Total Dose Components Time = 0.000E+00.................................... 10 Time = 1.000E+00.................................... 11 Time = 3.000E+00.................................... 12 Time = 1.000E+01.................................... 13 Time = 3.000E+01.................................... 14 Time = 1.000E+02.................................... 15 Time = 3.000E+02.................................... 16 Time = 1.000E+03.................................... 17 Dose/Source Ratios Summed Over All Pathways.............. 18 Single Radionuclide Soil Guidelines...................... 18 Dose Per Nuclide Summed Over All Pathways................ 19 Soil Concentration Per Nuclide........................... 19
RESRAD, Version 7.0 T1/2 Limit = 30 days 12/06/2014 16:15 Page 2 Summary : Zion Subsurface Soil 100 m^2 120614 File : C:\\RESRAD_FAMILY\\RESRAD\\7.0\\USERFILES\\ZION SUBSURFACE SOIL DCGL.RAD Dose Conversion Factor (and Related) Parameter Summary Dose Library: Subsurface Soil DCGL 120614 Plus FGR 11 Current Base Parameter Menu Parameter Value# Case* Name HHHH A-1 DCF's for external ground radiation, (mrem/yr)/(pCi/g)
A-1 Ba-137m (Source: FGR 12) 3.606E+00 3.606E+00 DCF1( 1)
A-1 Co-60 (Source: FGR 12) 1.622E+01 1.622E+01 DCF1( 2)
A-1 Cs-134 (Source: FGR 12) 9.472E+00 9.472E+00 DCF1( 3)
A-1 Cs-137 (Source: FGR 12) 7.510E-04 7.510E-04 DCF1( 4)
A-1 Ni-63 (Source: FGR 12) 0.000E+00 0.000E+00 DCF1( 5)
A-1 Sr-90 (Source: FGR 12) 7.043E-04 7.043E-04 DCF1( 6)
A-1 Y-90 (Source: FGR 12) 2.391E-02 2.391E-02 DCF1( 7)
B-1 Dose conversion factors for inhalation, mrem/pCi:
B-1 Co-60 2.190E-04 2.190E-04 DCF2( 1)
B-1 Cs-134 4.620E-05 4.620E-05 DCF2( 2)
B-1 Cs-137+D 3.190E-05 3.190E-05 DCF2( 3)
B-1 Ni-63 6.290E-06 6.290E-06 DCF2( 4)
B-1 Sr-90+D 1.308E-03 1.300E-03 DCF2( 5)
D-1 Dose conversion factors for ingestion, mrem/pCi:
D-1 Co-60 2.690E-05 2.690E-05 DCF3( 1)
D-1 Cs-134 7.330E-05 7.330E-05 DCF3( 2)
D-1 Cs-137+D 5.000E-05 5.000E-05 DCF3( 3)
D-1 Ni-63 5.770E-07 5.770E-07 DCF3( 4)
D-1 Sr-90+D 1.528E-04 1.420E-04 DCF3( 5)
D-34 Food transfer factors:
D-34 Co-60, plant/soil concentration ratio, dimensionless 1.500E-01 8.000E-02 RTF( 1,1)
D-34 Co-60, beef/livestock-intake ratio, (pCi/kg)/(pCi/d) 5.800E-02 2.000E-02 RTF( 1,2)
D-34 Co-60, milk/livestock-intake ratio, (pCi/L)/(pCi/d) 2.000E-03 2.000E-03 RTF( 1,3)
D-34 D-34 Cs-134, plant/soil concentration ratio, dimensionless 7.800E-02 4.000E-02 RTF( 2,1)
D-34 Cs-134, beef/livestock-intake ratio, (pCi/kg)/(pCi/d) 6.500E-02 3.000E-02 RTF( 2,2)
D-34 Cs-134, milk/livestock-intake ratio, (pCi/L)/(pCi/d) 1.400E-02 8.000E-03 RTF( 2,3)
D-34 D-34 Cs-137+D, plant/soil concentration ratio, dimensionless 7.800E-02 4.000E-02 RTF( 3,1)
D-34 Cs-137+D, beef/livestock-intake ratio, (pCi/kg)/(pCi/d) 6.500E-02 3.000E-02 RTF( 3,2)
D-34 Cs-137+D, milk/livestock-intake ratio, (pCi/L)/(pCi/d) 1.400E-02 8.000E-03 RTF( 3,3)
D-34 D-34 Ni-63, plant/soil concentration ratio, dimensionless 9.200E-02 5.000E-02 RTF( 4,1)
D-34 Ni-63, beef/livestock-intake ratio, (pCi/kg)/(pCi/d) 5.000E-03 5.000E-03 RTF( 4,2)
D-34 Ni-63, milk/livestock-intake ratio, (pCi/L)/(pCi/d) 3.200E-02 2.000E-02 RTF( 4,3)
D-34 D-34 Sr-90+D, plant/soil concentration ratio, dimensionless 5.900E-01 3.000E-01 RTF( 5,1)
D-34 Sr-90+D, beef/livestock-intake ratio, (pCi/kg)/(pCi/d) 8.000E-03 8.000E-03 RTF( 5,2)
D-34 Sr-90+D, milk/livestock-intake ratio, (pCi/L)/(pCi/d) 2.700E-03 2.000E-03 RTF( 5,3)
D-5 Bioaccumulation factors, fresh water, L/kg:
D-5 Co-60, fish 3.000E+02 3.000E+02 BIOFAC( 1,1)
D-5 Co-60, crustacea and mollusks 2.000E+02 2.000E+02 BIOFAC( 1,2)
D-5 D-5 Cs-134, fish 2.000E+03 2.000E+03 BIOFAC( 2,1)
D-5 Cs-134, crustacea and mollusks 1.000E+02 1.000E+02 BIOFAC( 2,2)
RESRAD, Version 7.0 T1/2 Limit = 30 days 12/06/2014 16:15 Page 3 Summary : Zion Subsurface Soil 100 m^2 120614 File : C:\\RESRAD_FAMILY\\RESRAD\\7.0\\USERFILES\\ZION SUBSURFACE SOIL DCGL.RAD Dose Conversion Factor (and Related) Parameter Summary (continued)
Dose Library: Subsurface Soil DCGL 120614 Plus FGR 11 Current Base Parameter Menu Parameter Value# Case* Name HHHH D-5 Cs-137+D, fish 2.000E+03 2.000E+03 BIOFAC( 3,1)
D-5 Cs-137+D, crustacea and mollusks 1.000E+02 1.000E+02 BIOFAC( 3,2)
D-5 D-5 Ni-63, fish 1.000E+02 1.000E+02 BIOFAC( 4,1)
D-5 Ni-63, crustacea and mollusks 1.000E+02 1.000E+02 BIOFAC( 4,2)
D-5 D-5 Sr-90+D, fish 6.000E+01 6.000E+01 BIOFAC( 5,1)
D-5 Sr-90+D, crustacea and mollusks 1.000E+02 1.000E+02 BIOFAC( 5,2)
- For DCF1(xxx) only, factors are for infinite depth & area. See ETFG table in Ground Pathway of Detailed Report.
- Base Case means Default.Lib w/o Associate Nuclide contributions.
RESRAD, Version 7.0 T1/2 Limit = 30 days 12/06/2014 16:15 Page 4 Summary : Zion Subsurface Soil 100 m^2 120614 File : C:\\RESRAD_FAMILY\\RESRAD\\7.0\\USERFILES\\ZION SUBSURFACE SOIL DCGL.RAD Site-Specific Parameter Summary User Used by RESRAD Parameter Menu Parameter Input Default (If different from user input) Name HHHHH R011 Area of contaminated zone (m**2) 1.000E+02 1.000E+04 --- AREA R011 Thickness of contaminated zone (m) 1.000E+00 2.000E+00 --- THICK0 R011 Fraction of contamination that is submerged 0.000E+00 0.000E+00 --- SUBMFRACT R011 Length parallel to aquifer flow (m) 1.130E+01 1.000E+02 --- LCZPAQ R011 Basic radiation dose limit (mrem/yr) 2.500E+01 3.000E+01 --- BRDL R011 Time since placement of material (yr) 0.000E+00 0.000E+00 --- TI R011 Times for calculations (yr) 1.000E+00 1.000E+00 --- T( 2)
R011 Times for calculations (yr) 3.000E+00 3.000E+00 --- T( 3)
R011 Times for calculations (yr) 1.000E+01 1.000E+01 --- T( 4)
R011 Times for calculations (yr) 3.000E+01 3.000E+01 --- T( 5)
R011 Times for calculations (yr) 1.000E+02 1.000E+02 --- T( 6)
R011 Times for calculations (yr) 3.000E+02 3.000E+02 --- T( 7)
R011 Times for calculations (yr) 1.000E+03 1.000E+03 --- T( 8)
R011 Times for calculations (yr) not used 0.000E+00 --- T( 9)
R011 Times for calculations (yr) not used 0.000E+00 --- T(10)
R012 Initial principal radionuclide (pCi/g): Co-60 1.000E+00 0.000E+00 --- S1(1)
R012 Initial principal radionuclide (pCi/g): Cs-134 1.000E+00 0.000E+00 --- S1(2)
R012 Initial principal radionuclide (pCi/g): Cs-137 1.000E+00 0.000E+00 --- S1(3)
R012 Initial principal radionuclide (pCi/g): Ni-63 1.000E+00 0.000E+00 --- S1(4)
R012 Initial principal radionuclide (pCi/g): Sr-90 1.000E+00 0.000E+00 --- S1(5)
R012 Concentration in groundwater (pCi/L): Co-60 not used 0.000E+00 --- W1( 1)
R012 Concentration in groundwater (pCi/L): Cs-134 not used 0.000E+00 --- W1( 2)
R012 Concentration in groundwater (pCi/L): Cs-137 not used 0.000E+00 --- W1( 3)
R012 Concentration in groundwater (pCi/L): Ni-63 not used 0.000E+00 --- W1( 4)
R012 Concentration in groundwater (pCi/L): Sr-90 not used 0.000E+00 --- W1( 5)
R013 Cover depth (m) 0.000E+00 0.000E+00 --- COVER0 R013 Density of cover material (g/cm**3) not used 1.500E+00 --- DENSCV R013 Cover depth erosion rate (m/yr) not used 1.000E-03 --- VCV R013 Density of contaminated zone (g/cm**3) 1.800E+00 1.500E+00 --- DENSCZ R013 Contaminated zone erosion rate (m/yr) 1.500E-03 1.000E-03 --- VCZ R013 Contaminated zone total porosity 3.500E-01 4.000E-01 --- TPCZ R013 Contaminated zone field capacity 6.600E-02 2.000E-01 --- FCCZ R013 Contaminated zone hydraulic conductivity (m/yr) 2.880E+03 1.000E+01 --- HCCZ R013 Contaminated zone b parameter 9.700E-01 5.300E+00 --- BCZ R013 Average annual wind speed (m/sec) 4.200E+00 2.000E+00 --- WIND R013 Humidity in air (g/m**3) not used 8.000E+00 --- HUMID R013 Evapotranspiration coefficient 6.250E-01 5.000E-01 --- EVAPTR R013 Precipitation (m/yr) 8.300E-01 1.000E+00 --- PRECIP R013 Irrigation (m/yr) 1.900E-01 2.000E-01 --- RI R013 Irrigation mode overhead overhead --- IDITCH R013 Runoff coefficient 2.000E-01 2.000E-01 --- RUNOFF R013 Watershed area for nearby stream or pond (m**2) 1.000E+06 1.000E+06 --- WAREA R013 Accuracy for water/soil computations 1.000E-03 1.000E-03 --- EPS R014 Density of saturated zone (g/cm**3) 1.800E+00 1.500E+00 --- DENSAQ R014 Saturated zone total porosity 3.500E-01 4.000E-01 --- TPSZ R014 Saturated zone effective porosity 2.900E-01 2.000E-01 --- EPSZ R014 Saturated zone field capacity 6.600E-02 2.000E-01 --- FCSZ
RESRAD, Version 7.0 T1/2 Limit = 30 days 12/06/2014 16:15 Page 5 Summary : Zion Subsurface Soil 100 m^2 120614 File : C:\\RESRAD_FAMILY\\RESRAD\\7.0\\USERFILES\\ZION SUBSURFACE SOIL DCGL.RAD Site-Specific Parameter Summary (continued)
User Used by RESRAD Parameter Menu Parameter Input Default (If different from user input) Name HHHHH R014 Saturated zone hydraulic conductivity (m/yr) 2.880E+03 1.000E+02 --- HCSZ R014 Saturated zone hydraulic gradient 3.900E-03 2.000E-02 --- HGWT R014 Saturated zone b parameter not used 5.300E+00 --- BSZ R014 Water table drop rate (m/yr) 0.000E+00 1.000E-03 --- VWT R014 Well pump intake depth (m below water table) 3.300E+00 1.000E+01 --- DWIBWT R014 Model: Nondispersion (ND) or Mass-Balance (MB) ND ND --- MODEL R014 Well pumping rate (m**3/yr) 2.250E+03 2.500E+02 --- UW R015 Number of unsaturated zone strata 1 1 --- NS R015 Unsat. zone 1, thickness (m) 2.600E+00 4.000E+00 --- H(1)
R015 Unsat. zone 1, soil density (g/cm**3) 1.800E+00 1.500E+00 --- DENSUZ(1)
R015 Unsat. zone 1, total porosity 3.500E-01 4.000E-01 --- TPUZ(1)
R015 Unsat. zone 1, effective porosity 2.900E-01 2.000E-01 --- EPUZ(1)
R015 Unsat. zone 1, field capacity 6.600E-02 2.000E-01 --- FCUZ(1)
R015 Unsat. zone 1, soil-specific b parameter 9.700E-01 5.300E+00 --- BUZ(1)
R015 Unsat. zone 1, hydraulic conductivity (m/yr) 2.880E+03 1.000E+01 --- HCUZ(1)
R016 Distribution coefficients for Co-60 R016 Contaminated zone (cm**3/g) 1.161E+03 1.000E+03 --- DCNUCC( 1)
R016 Unsaturated zone 1 (cm**3/g) 1.161E+03 1.000E+03 --- DCNUCU( 1,1)
R016 Saturated zone (cm**3/g) 1.161E+03 1.000E+03 --- DCNUCS( 1)
R016 Leach rate (/yr) 0.000E+00 0.000E+00 1.532E-04 ALEACH( 1)
R016 Solubility constant 0.000E+00 0.000E+00 not used SOLUBK( 1)
R016 Distribution coefficients for Cs-134 R016 Contaminated zone (cm**3/g) 6.150E+02 4.600E+03 --- DCNUCC( 2)
R016 Unsaturated zone 1 (cm**3/g) 6.150E+02 4.600E+03 --- DCNUCU( 2,1)
R016 Saturated zone (cm**3/g) 6.150E+02 4.600E+03 --- DCNUCS( 2)
R016 Leach rate (/yr) 0.000E+00 0.000E+00 2.893E-04 ALEACH( 2)
R016 Solubility constant 0.000E+00 0.000E+00 not used SOLUBK( 2)
R016 Distribution coefficients for Cs-137 R016 Contaminated zone (cm**3/g) 6.150E+02 4.600E+03 --- DCNUCC( 3)
R016 Unsaturated zone 1 (cm**3/g) 6.150E+02 4.600E+03 --- DCNUCU( 3,1)
R016 Saturated zone (cm**3/g) 6.150E+02 4.600E+03 --- DCNUCS( 3)
R016 Leach rate (/yr) 0.000E+00 0.000E+00 2.893E-04 ALEACH( 3)
R016 Solubility constant 0.000E+00 0.000E+00 not used SOLUBK( 3)
R016 Distribution coefficients for Ni-63 R016 Contaminated zone (cm**3/g) 6.200E+01 1.000E+03 --- DCNUCC( 4)
R016 Unsaturated zone 1 (cm**3/g) 6.200E+01 1.000E+03 --- DCNUCU( 4,1)
R016 Saturated zone (cm**3/g) 6.200E+01 1.000E+03 --- DCNUCS( 4)
R016 Leach rate (/yr) 0.000E+00 0.000E+00 2.868E-03 ALEACH( 4)
R016 Solubility constant 0.000E+00 0.000E+00 not used SOLUBK( 4)
R016 Distribution coefficients for Sr-90 R016 Contaminated zone (cm**3/g) 2.300E+00 3.000E+01 --- DCNUCC( 5)
R016 Unsaturated zone 1 (cm**3/g) 2.300E+00 3.000E+01 --- DCNUCU( 5,1)
R016 Saturated zone (cm**3/g) 2.300E+00 3.000E+01 --- DCNUCS( 5)
R016 Leach rate (/yr) 0.000E+00 0.000E+00 7.614E-02 ALEACH( 5)
R016 Solubility constant 0.000E+00 0.000E+00 not used SOLUBK( 5)
RESRAD, Version 7.0 T1/2 Limit = 30 days 12/06/2014 16:15 Page 6 Summary : Zion Subsurface Soil 100 m^2 120614 File : C:\\RESRAD_FAMILY\\RESRAD\\7.0\\USERFILES\\ZION SUBSURFACE SOIL DCGL.RAD Site-Specific Parameter Summary (continued)
User Used by RESRAD Parameter Menu Parameter Input Default (If different from user input) Name HHHHH R017 Inhalation rate (m**3/yr) 8.400E+03 8.400E+03 --- INHALR R017 Mass loading for inhalation (g/m**3) 2.350E-05 1.000E-04 --- MLINH R017 Exposure duration 3.000E+01 3.000E+01 --- ED R017 Shielding factor, inhalation 5.500E-01 4.000E-01 --- SHF3 R017 Shielding factor, external gamma 4.000E-01 7.000E-01 --- SHF1 R017 Fraction of time spent indoors 6.490E-01 5.000E-01 --- FIND R017 Fraction of time spent outdoors (on site) 1.240E-01 2.500E-01 --- FOTD R017 Shape factor flag, external gamma 1.000E+00 1.000E+00 >0 shows circular AREA. FS R017 Radii of shape factor array (used if FS = -1):
R017 Outer annular radius (m), ring 1: not used 5.000E+01 --- RAD_SHAPE( 1)
R017 Outer annular radius (m), ring 2: not used 7.071E+01 --- RAD_SHAPE( 2)
R017 Outer annular radius (m), ring 3: not used 0.000E+00 --- RAD_SHAPE( 3)
R017 Outer annular radius (m), ring 4: not used 0.000E+00 --- RAD_SHAPE( 4)
R017 Outer annular radius (m), ring 5: not used 0.000E+00 --- RAD_SHAPE( 5)
R017 Outer annular radius (m), ring 6: not used 0.000E+00 --- RAD_SHAPE( 6)
R017 Outer annular radius (m), ring 7: not used 0.000E+00 --- RAD_SHAPE( 7)
R017 Outer annular radius (m), ring 8: not used 0.000E+00 --- RAD_SHAPE( 8)
R017 Outer annular radius (m), ring 9: not used 0.000E+00 --- RAD_SHAPE( 9)
R017 Outer annular radius (m), ring 10: not used 0.000E+00 --- RAD_SHAPE(10)
R017 Outer annular radius (m), ring 11: not used 0.000E+00 --- RAD_SHAPE(11)
R017 Outer annular radius (m), ring 12: not used 0.000E+00 --- RAD_SHAPE(12)
R017 Fractions of annular areas within AREA:
R017 Ring 1 not used 1.000E+00 --- FRACA( 1)
R017 Ring 2 not used 2.732E-01 --- FRACA( 2)
R017 Ring 3 not used 0.000E+00 --- FRACA( 3)
R017 Ring 4 not used 0.000E+00 --- FRACA( 4)
R017 Ring 5 not used 0.000E+00 --- FRACA( 5)
R017 Ring 6 not used 0.000E+00 --- FRACA( 6)
R017 Ring 7 not used 0.000E+00 --- FRACA( 7)
R017 Ring 8 not used 0.000E+00 --- FRACA( 8)
R017 Ring 9 not used 0.000E+00 --- FRACA( 9)
R017 Ring 10 not used 0.000E+00 --- FRACA(10)
R017 Ring 11 not used 0.000E+00 --- FRACA(11)
R017 Ring 12 not used 0.000E+00 --- FRACA(12)
R018 Fruits, vegetables and grain consumption (kg/yr) 1.120E+02 1.600E+02 --- DIET(1)
R018 Leafy vegetable consumption (kg/yr) 2.140E+01 1.400E+01 --- DIET(2)
R018 Milk consumption (L/yr) 2.330E+02 9.200E+01 --- DIET(3)
R018 Meat and poultry consumption (kg/yr) 6.510E+01 6.300E+01 --- DIET(4)
R018 Fish consumption (kg/yr) not used 5.400E+00 --- DIET(5)
R018 Other seafood consumption (kg/yr) not used 9.000E-01 --- DIET(6)
R018 Soil ingestion rate (g/yr) 1.830E+01 3.650E+01 --- SOIL R018 Drinking water intake (L/yr) 4.780E+02 5.100E+02 --- DWI R018 Contamination fraction of drinking water 1.000E+00 1.000E+00 --- FDW R018 Contamination fraction of household water not used 1.000E+00 --- FHHW R018 Contamination fraction of livestock water 1.000E+00 1.000E+00 --- FLW R018 Contamination fraction of irrigation water 1.000E+00 1.000E+00 --- FIRW R018 Contamination fraction of aquatic food not used 5.000E-01 --- FR9 R018 Contamination fraction of plant food -1 -1 0.500E-01 FPLANT
RESRAD, Version 7.0 T1/2 Limit = 30 days 12/06/2014 16:15 Page 7 Summary : Zion Subsurface Soil 100 m^2 120614 File : C:\\RESRAD_FAMILY\\RESRAD\\7.0\\USERFILES\\ZION SUBSURFACE SOIL DCGL.RAD Site-Specific Parameter Summary (continued)
User Used by RESRAD Parameter Menu Parameter Input Default (If different from user input) Name HHHHH R018 Contamination fraction of meat -1 -1 0.500E-02 FMEAT R018 Contamination fraction of milk -1 -1 0.500E-02 FMILK R019 Livestock fodder intake for meat (kg/day) 2.830E+01 6.800E+01 --- LFI5 R019 Livestock fodder intake for milk (kg/day) 6.520E+01 5.500E+01 --- LFI6 R019 Livestock water intake for meat (L/day) 5.060E+01 5.000E+01 --- LWI5 R019 Livestock water intake for milk (L/day) 6.000E+01 1.600E+02 --- LWI6 R019 Livestock soil intake (kg/day) 5.000E-01 5.000E-01 --- LSI R019 Mass loading for foliar deposition (g/m**3) 4.000E-04 1.000E-04 --- MLFD R019 Depth of soil mixing layer (m) 2.300E-01 1.500E-01 --- DM R019 Depth of roots (m) 1.220E+00 9.000E-01 --- DROOT R019 Drinking water fraction from ground water 1.000E+00 1.000E+00 --- FGWDW R019 Household water fraction from ground water not used 1.000E+00 --- FGWHH R019 Livestock water fraction from ground water 1.000E+00 1.000E+00 --- FGWLW R019 Irrigation fraction from ground water 1.000E+00 1.000E+00 --- FGWIR R19B Wet weight crop yield for Non-Leafy (kg/m**2) 1.750E+00 7.000E-01 --- YV(1)
R19B Wet weight crop yield for Leafy (kg/m**2) 2.900E+00 1.500E+00 --- YV(2)
R19B Wet weight crop yield for Fodder (kg/m**2) 1.900E+00 1.100E+00 --- YV(3)
R19B Growing Season for Non-Leafy (years) 2.460E-01 1.700E-01 --- TE(1)
R19B Growing Season for Leafy (years) 1.230E-01 2.500E-01 --- TE(2)
R19B Growing Season for Fodder (years) 8.200E-02 8.000E-02 --- TE(3)
R19B Translocation Factor for Non-Leafy 1.000E-01 1.000E-01 --- TIV(1)
R19B Translocation Factor for Leafy 1.000E+00 1.000E+00 --- TIV(2)
R19B Translocation Factor for Fodder 1.000E+00 1.000E+00 --- TIV(3)
R19B Dry Foliar Interception Fraction for Non-Leafy 3.500E-01 2.500E-01 --- RDRY(1)
R19B Dry Foliar Interception Fraction for Leafy 3.500E-01 2.500E-01 --- RDRY(2)
R19B Dry Foliar Interception Fraction for Fodder 3.500E-01 2.500E-01 --- RDRY(3)
R19B Wet Foliar Interception Fraction for Non-Leafy 3.500E-01 2.500E-01 --- RWET(1)
R19B Wet Foliar Interception Fraction for Leafy 5.800E-01 2.500E-01 --- RWET(2)
R19B Wet Foliar Interception Fraction for Fodder 3.500E-01 2.500E-01 --- RWET(3)
R19B Weathering Removal Constant for Vegetation 3.300E+01 2.000E+01 --- WLAM C14 C-12 concentration in water (g/cm**3) not used 2.000E-05 --- C12WTR C14 C-12 concentration in contaminated soil (g/g) not used 3.000E-02 --- C12CZ C14 Fraction of vegetation carbon from soil not used 2.000E-02 --- CSOIL C14 Fraction of vegetation carbon from air not used 9.800E-01 --- CAIR C14 C-14 evasion layer thickness in soil (m) not used 3.000E-01 --- DMC C14 C-14 evasion flux rate from soil (1/sec) not used 7.000E-07 --- EVSN C14 C-12 evasion flux rate from soil (1/sec) not used 1.000E-10 --- REVSN C14 Fraction of grain in beef cattle feed not used 8.000E-01 --- AVFG4 C14 Fraction of grain in milk cow feed not used 2.000E-01 --- AVFG5 STOR Storage times of contaminated foodstuffs (days):
STOR Fruits, non-leafy vegetables, and grain 1.400E+01 1.400E+01 --- STOR_T(1)
STOR Leafy vegetables 1.000E+00 1.000E+00 --- STOR_T(2)
STOR Milk 1.000E+00 1.000E+00 --- STOR_T(3)
STOR Meat and poultry 1.000E+00 2.000E+01 --- STOR_T(4)
STOR Fish 7.000E+00 7.000E+00 --- STOR_T(5)
STOR Crustacea and mollusks 7.000E+00 7.000E+00 --- STOR_T(6)
RESRAD, Version 7.0 T1/2 Limit = 30 days 12/06/2014 16:15 Page 8 Summary : Zion Subsurface Soil 100 m^2 120614 File : C:\\RESRAD_FAMILY\\RESRAD\\7.0\\USERFILES\\ZION SUBSURFACE SOIL DCGL.RAD Site-Specific Parameter Summary (continued)
User Used by RESRAD Parameter Menu Parameter Input Default (If different from user input) Name HHHHH STOR Well water 1.000E+00 1.000E+00 --- STOR_T(7)
STOR Surface water 1.000E+00 1.000E+00 --- STOR_T(8)
STOR Livestock fodder 4.500E+01 4.500E+01 --- STOR_T(9)
R021 Thickness of building foundation (m) not used 1.500E-01 --- FLOOR1 R021 Bulk density of building foundation (g/cm**3) not used 2.400E+00 --- DENSFL R021 Total porosity of the cover material not used 4.000E-01 --- TPCV R021 Total porosity of the building foundation not used 1.000E-01 --- TPFL R021 Volumetric water content of the cover material not used 5.000E-02 --- PH2OCV R021 Volumetric water content of the foundation not used 3.000E-02 --- PH2OFL R021 Diffusion coefficient for radon gas (m/sec):
R021 in cover material not used 2.000E-06 --- DIFCV R021 in foundation material not used 3.000E-07 --- DIFFL R021 in contaminated zone soil not used 2.000E-06 --- DIFCZ R021 Radon vertical dimension of mixing (m) not used 2.000E+00 --- HMIX R021 Average building air exchange rate (1/hr) not used 5.000E-01 --- REXG R021 Height of the building (room) (m) not used 2.500E+00 --- HRM R021 Building interior area factor not used 0.000E+00 --- FAI R021 Building depth below ground surface (m) not used -1.000E+00 --- DMFL R021 Emanating power of Rn-222 gas not used 2.500E-01 --- EMANA(1)
R021 Emanating power of Rn-220 gas not used 1.500E-01 --- EMANA(2)
TITL Number of graphical time points 512 --- --- NPTS TITL Maximum number of integration points for dose 17 --- --- LYMAX TITL Maximum number of integration points for risk 17 --- --- KYMAX
Summary of Pathway Selections Pathway User Selection H
1 -- external gamma active 2 -- inhalation (w/o radon) active 3 -- plant ingestion active 4 -- meat ingestion active 5 -- milk ingestion active 6 -- aquatic foods suppressed 7 -- drinking water active 8 -- soil ingestion active 9 -- radon suppressed Find peak pathway doses active
RESRAD, Version 7.0 T1/2 Limit = 30 days 12/06/2014 16:15 Page 9 Summary : Zion Subsurface Soil 100 m^2 120614 File : C:\\RESRAD_FAMILY\\RESRAD\\7.0\\USERFILES\\ZION SUBSURFACE SOIL DCGL.RAD Contaminated Zone Dimensions Initial Soil Concentrations, pCi/g Area: 100.00 square meters Co-60 1.000E+00 Thickness: 1.00 meters Cs-134 1.000E+00 Cover Depth: 0.00 meters Cs-137 1.000E+00 Ni-63 1.000E+00 Sr-90 1.000E+00 Total Dose TDOSE(t), mrem/yr Basic Radiation Dose Limit = 2.500E+01 mrem/yr Total Mixture Sum M(t) = Fraction of Basic Dose Limit Received at Time (t) t (years): 0.000E+00 1.000E+00 3.000E+00 1.000E+01 3.000E+01 1.000E+02 3.000E+02 1.000E+03 TDOSE(t): 8.617E+00 7.273E+00 5.347E+00 2.329E+00 7.467E-01 1.017E-01 9.706E-04 2.466E-08 M(t): 3.447E-01 2.909E-01 2.139E-01 9.315E-02 2.987E-02 4.067E-03 3.883E-05 9.863E-10 Maximum TDOSE(t): 8.617E+00 mrem/yr at t = 0.000E+00 years
RESRAD, Version 7.0 T1/2 Limit = 30 days 12/06/2014 16:15 Page 10 Summary : Zion Subsurface Soil 100 m^2 120614 File : C:\\RESRAD_FAMILY\\RESRAD\\7.0\\USERFILES\\ZION SUBSURFACE SOIL DCGL.RAD Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)
As mrem/yr and Fraction of Total Dose At t = 0.000E+00 years Water Independent Pathways (Inhalation excludes radon)
Ground Inhalation Radon Plant Meat Milk Soil Radio-Nuclide mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract.
Co-60 4.594E+00 0.5331 9.858E-07 0.0000 0.000E+00 0.0000 2.066E-02 0.0024 1.893E-03 0.0002 4.999E-04 0.0001 3.565E-05 0.0000 Cs-134 2.426E+00 0.2815 1.885E-07 0.0000 0.000E+00 0.0000 2.653E-02 0.0031 3.041E-03 0.0004 4.739E-03 0.0005 8.807E-05 0.0000 Cs-137 1.015E+00 0.1178 1.515E-07 0.0000 0.000E+00 0.0000 2.106E-02 0.0024 2.414E-03 0.0003 3.762E-03 0.0004 6.991E-05 0.0000 Ni-63 0.000E+00 0.0000 3.007E-08 0.0000 0.000E+00 0.0000 2.886E-04 0.0000 2.461E-06 0.0000 1.159E-04 0.0000 8.122E-07 0.0000 Sr-90 7.080E-03 0.0008 5.981E-06 0.0000 0.000E+00 0.0000 4.697E-01 0.0545 5.414E-03 0.0006 1.477E-02 0.0017 2.057E-04 0.0000 Total 8.041E+00 0.9332 7.337E-06 0.0000 0.000E+00 0.0000 5.383E-01 0.0625 1.276E-02 0.0015 2.388E-02 0.0028 4.001E-04 0.0000 Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)
As mrem/yr and Fraction of Total Dose At t = 0.000E+00 years Water Dependent Pathways Water Fish Radon Plant Meat Milk All Pathways*
Radio-Nuclide mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract.
Co-60 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 4.617E+00 0.5358 Cs-134 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 2.460E+00 0.2855 Cs-137 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.042E+00 0.1209 Ni-63 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 4.079E-04 0.0000 Sr-90 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 4.972E-01 0.0577 Total 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 8.617E+00 1.0000
- Sum of all water independent and dependent pathways.
RESRAD, Version 7.0 T1/2 Limit = 30 days 12/06/2014 16:15 Page 11 Summary : Zion Subsurface Soil 100 m^2 120614 File : C:\\RESRAD_FAMILY\\RESRAD\\7.0\\USERFILES\\ZION SUBSURFACE SOIL DCGL.RAD Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)
As mrem/yr and Fraction of Total Dose At t = 1.000E+00 years Water Independent Pathways (Inhalation excludes radon)
Ground Inhalation Radon Plant Meat Milk Soil Radio-Nuclide mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract.
Co-60 4.027E+00 0.5537 8.642E-07 0.0000 0.000E+00 0.0000 1.808E-02 0.0025 1.657E-03 0.0002 4.376E-04 0.0001 3.126E-05 0.0000 Cs-134 1.733E+00 0.2383 1.347E-07 0.0000 0.000E+00 0.0000 1.893E-02 0.0026 2.171E-03 0.0003 3.382E-03 0.0005 6.294E-05 0.0000 Cs-137 9.914E-01 0.1363 1.480E-07 0.0000 0.000E+00 0.0000 2.055E-02 0.0028 2.356E-03 0.0003 3.670E-03 0.0005 6.831E-05 0.0000 Ni-63 0.000E+00 0.0000 2.978E-08 0.0000 0.000E+00 0.0000 2.854E-04 0.0000 2.434E-06 0.0000 1.146E-04 0.0000 8.043E-07 0.0000 Sr-90 6.405E-03 0.0009 5.411E-06 0.0000 0.000E+00 0.0000 4.244E-01 0.0584 4.894E-03 0.0007 1.335E-02 0.0018 1.861E-04 0.0000 Total 6.759E+00 0.9292 6.588E-06 0.0000 0.000E+00 0.0000 4.822E-01 0.0663 1.108E-02 0.0015 2.096E-02 0.0029 3.494E-04 0.0000 Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)
As mrem/yr and Fraction of Total Dose At t = 1.000E+00 years Water Dependent Pathways Water Fish Radon Plant Meat Milk All Pathways*
Radio-Nuclide mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract.
Co-60 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 4.047E+00 0.5565 Cs-134 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.758E+00 0.2417 Cs-137 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.018E+00 0.1400 Ni-63 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 4.033E-04 0.0001 Sr-90 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 4.492E-01 0.0618 Total 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 7.273E+00 1.0000
- Sum of all water independent and dependent pathways.
RESRAD, Version 7.0 T1/2 Limit = 30 days 12/06/2014 16:15 Page 12 Summary : Zion Subsurface Soil 100 m^2 120614 File : C:\\RESRAD_FAMILY\\RESRAD\\7.0\\USERFILES\\ZION SUBSURFACE SOIL DCGL.RAD Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)
As mrem/yr and Fraction of Total Dose At t = 3.000E+00 years Water Independent Pathways (Inhalation excludes radon)
Ground Inhalation Radon Plant Meat Milk Soil Radio-Nuclide mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract.
Co-60 3.095E+00 0.5788 6.641E-07 0.0000 0.000E+00 0.0000 1.385E-02 0.0026 1.270E-03 0.0002 3.354E-04 0.0001 2.402E-05 0.0000 Cs-134 8.853E-01 0.1656 6.880E-08 0.0000 0.000E+00 0.0000 9.640E-03 0.0018 1.106E-03 0.0002 1.722E-03 0.0003 3.214E-05 0.0000 Cs-137 9.463E-01 0.1770 1.413E-07 0.0000 0.000E+00 0.0000 1.955E-02 0.0037 2.243E-03 0.0004 3.494E-03 0.0007 6.520E-05 0.0000 Ni-63 0.000E+00 0.0000 2.920E-08 0.0000 0.000E+00 0.0000 2.790E-04 0.0001 2.381E-06 0.0000 1.121E-04 0.0000 7.887E-07 0.0000 Sr-90 5.242E-03 0.0010 4.428E-06 0.0000 0.000E+00 0.0000 3.463E-01 0.0648 3.994E-03 0.0007 1.089E-02 0.0020 1.523E-04 0.0000 Total 4.932E+00 0.9224 5.332E-06 0.0000 0.000E+00 0.0000 3.896E-01 0.0729 8.615E-03 0.0016 1.656E-02 0.0031 2.744E-04 0.0001 Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)
As mrem/yr and Fraction of Total Dose At t = 3.000E+00 years Water Dependent Pathways Water Fish Radon Plant Meat Milk All Pathways*
Radio-Nuclide mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract.
Co-60 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 3.110E+00 0.5817 Cs-134 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 8.978E-01 0.1679 Cs-137 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 9.717E-01 0.1817 Ni-63 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 3.943E-04 0.0001 Sr-90 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 3.666E-01 0.0686 Total 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 5.347E+00 1.0000
- Sum of all water independent and dependent pathways.
RESRAD, Version 7.0 T1/2 Limit = 30 days 12/06/2014 16:15 Page 13 Summary : Zion Subsurface Soil 100 m^2 120614 File : C:\\RESRAD_FAMILY\\RESRAD\\7.0\\USERFILES\\ZION SUBSURFACE SOIL DCGL.RAD Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)
As mrem/yr and Fraction of Total Dose At t = 1.000E+01 years Water Independent Pathways (Inhalation excludes radon)
Ground Inhalation Radon Plant Meat Milk Soil Radio-Nuclide mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract.
Co-60 1.232E+00 0.5288 2.643E-07 0.0000 0.000E+00 0.0000 5.454E-03 0.0023 5.008E-04 0.0002 1.321E-04 0.0001 9.558E-06 0.0000 Cs-134 8.427E-02 0.0362 6.549E-09 0.0000 0.000E+00 0.0000 9.079E-04 0.0004 1.044E-04 0.0000 1.624E-04 0.0001 3.059E-06 0.0000 Cs-137 8.041E-01 0.3453 1.200E-07 0.0000 0.000E+00 0.0000 1.644E-02 0.0071 1.890E-03 0.0008 2.941E-03 0.0013 5.540E-05 0.0000 Ni-63 0.000E+00 0.0000 2.727E-08 0.0000 0.000E+00 0.0000 2.578E-04 0.0001 2.204E-06 0.0000 1.037E-04 0.0000 7.365E-07 0.0000 Sr-90 2.599E-03 0.0011 2.196E-06 0.0000 0.000E+00 0.0000 1.699E-01 0.0729 1.960E-03 0.0008 5.345E-03 0.0023 7.550E-05 0.0000 Total 2.123E+00 0.9114 2.614E-06 0.0000 0.000E+00 0.0000 1.929E-01 0.0829 4.458E-03 0.0019 8.684E-03 0.0037 1.443E-04 0.0001 Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)
As mrem/yr and Fraction of Total Dose At t = 1.000E+01 years Water Dependent Pathways Water Fish Radon Plant Meat Milk All Pathways*
Radio-Nuclide mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract.
Co-60 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.238E+00 0.5315 Cs-134 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 8.545E-02 0.0367 Cs-137 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 8.254E-01 0.3545 Ni-63 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 3.644E-04 0.0002 Sr-90 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.799E-01 0.0772 Total 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 2.329E+00 1.0000
- Sum of all water independent and dependent pathways.
RESRAD, Version 7.0 T1/2 Limit = 30 days 12/06/2014 16:15 Page 14 Summary : Zion Subsurface Soil 100 m^2 120614 File : C:\\RESRAD_FAMILY\\RESRAD\\7.0\\USERFILES\\ZION SUBSURFACE SOIL DCGL.RAD Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)
As mrem/yr and Fraction of Total Dose At t = 3.000E+01 years Water Independent Pathways (Inhalation excludes radon)
Ground Inhalation Radon Plant Meat Milk Soil Radio-Nuclide mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract.
Co-60 8.850E-02 0.1185 1.899E-08 0.0000 0.000E+00 0.0000 3.800E-04 0.0005 3.503E-05 0.0000 9.223E-06 0.0000 6.869E-07 0.0000 Cs-134 1.017E-04 0.0001 7.904E-12 0.0000 0.000E+00 0.0000 1.062E-06 0.0000 1.230E-07 0.0000 1.907E-07 0.0000 3.692E-09 0.0000 Cs-137 5.049E-01 0.6762 7.538E-08 0.0000 0.000E+00 0.0000 1.001E-02 0.0134 1.159E-03 0.0016 1.797E-03 0.0024 3.479E-05 0.0000 Ni-63 0.000E+00 0.0000 2.242E-08 0.0000 0.000E+00 0.0000 2.055E-04 0.0003 1.768E-06 0.0000 8.289E-05 0.0001 6.055E-07 0.0000 Sr-90 3.502E-04 0.0005 2.959E-07 0.0000 0.000E+00 0.0000 2.219E-02 0.0297 2.564E-04 0.0003 6.987E-04 0.0009 1.017E-05 0.0000 Total 5.939E-01 0.7953 4.126E-07 0.0000 0.000E+00 0.0000 3.279E-02 0.0439 1.452E-03 0.0019 2.587E-03 0.0035 4.626E-05 0.0001 Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)
As mrem/yr and Fraction of Total Dose At t = 3.000E+01 years Water Dependent Pathways Water Fish Radon Plant Meat Milk All Pathways*
Radio-Nuclide mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract.
Co-60 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 8.893E-02 0.1191 Cs-134 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.031E-04 0.0001 Cs-137 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 5.179E-01 0.6936 Ni-63 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 2.908E-04 0.0004 Sr-90 1.153E-01 0.1544 0.000E+00 0.0000 0.000E+00 0.0000 5.562E-04 0.0007 4.885E-05 0.0001 9.308E-05 0.0001 1.395E-01 0.1868 Total 1.153E-01 0.1544 0.000E+00 0.0000 0.000E+00 0.0000 5.562E-04 0.0007 4.885E-05 0.0001 9.308E-05 0.0001 7.467E-01 1.0000
- Sum of all water independent and dependent pathways.
RESRAD, Version 7.0 T1/2 Limit = 30 days 12/06/2014 16:15 Page 15 Summary : Zion Subsurface Soil 100 m^2 120614 File : C:\\RESRAD_FAMILY\\RESRAD\\7.0\\USERFILES\\ZION SUBSURFACE SOIL DCGL.RAD Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)
As mrem/yr and Fraction of Total Dose At t = 1.000E+02 years Water Independent Pathways (Inhalation excludes radon)
Ground Inhalation Radon Plant Meat Milk Soil Radio-Nuclide mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract.
Co-60 8.806E-06 0.0001 1.890E-12 0.0000 0.000E+00 0.0000 3.365E-08 0.0000 3.152E-09 0.0000 8.229E-10 0.0000 6.835E-11 0.0000 Cs-134 6.211E-15 0.0000 4.827E-22 0.0000 0.000E+00 0.0000 5.774E-17 0.0000 6.870E-18 0.0000 1.051E-17 0.0000 2.255E-19 0.0000 Cs-137 9.907E-02 0.9744 1.479E-08 0.0000 0.000E+00 0.0000 1.748E-03 0.0172 2.080E-04 0.0020 3.180E-04 0.0031 6.825E-06 0.0001 Ni-63 0.000E+00 0.0000 1.129E-08 0.0000 0.000E+00 0.0000 9.214E-05 0.0009 8.120E-07 0.0000 3.761E-05 0.0004 3.051E-07 0.0000 Sr-90 3.145E-07 0.0000 2.657E-10 0.0000 0.000E+00 0.0000 1.774E-05 0.0002 2.058E-07 0.0000 5.596E-07 0.0000 9.137E-09 0.0000 Total 9.908E-02 0.9744 2.635E-08 0.0000 0.000E+00 0.0000 1.857E-03 0.0183 2.090E-04 0.0021 3.562E-04 0.0035 7.140E-06 0.0001 Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)
As mrem/yr and Fraction of Total Dose At t = 1.000E+02 years Water Dependent Pathways Water Fish Radon Plant Meat Milk All Pathways*
Radio-Nuclide mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract.
Co-60 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 8.844E-06 0.0001 Cs-134 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 6.286E-15 0.0000 Cs-137 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.013E-01 0.9968 Ni-63 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.309E-04 0.0013 Sr-90 1.679E-04 0.0017 0.000E+00 0.0000 0.000E+00 0.0000 8.178E-07 0.0000 7.285E-08 0.0000 1.402E-07 0.0000 1.877E-04 0.0018 Total 1.679E-04 0.0017 0.000E+00 0.0000 0.000E+00 0.0000 8.178E-07 0.0000 7.285E-08 0.0000 1.402E-07 0.0000 1.017E-01 1.0000
- Sum of all water independent and dependent pathways.
RESRAD, Version 7.0 T1/2 Limit = 30 days 12/06/2014 16:15 Page 16 Summary : Zion Subsurface Soil 100 m^2 120614 File : C:\\RESRAD_FAMILY\\RESRAD\\7.0\\USERFILES\\ZION SUBSURFACE SOIL DCGL.RAD Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)
As mrem/yr and Fraction of Total Dose At t = 3.000E+02 years Water Independent Pathways (Inhalation excludes radon)
Ground Inhalation Radon Plant Meat Milk Soil Radio-Nuclide mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract.
Co-60 3.235E-17 0.0000 6.944E-24 0.0000 0.000E+00 0.0000 7.998E-20 0.0000 8.085E-21 0.0000 2.029E-21 0.0000 2.512E-22 0.0000 Cs-134 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Cs-137 9.441E-04 0.9726 1.409E-10 0.0000 0.000E+00 0.0000 1.077E-05 0.0111 1.454E-06 0.0015 2.093E-06 0.0022 6.505E-08 0.0001 Ni-63 0.000E+00 0.0000 1.593E-09 0.0000 0.000E+00 0.0000 8.407E-06 0.0087 8.284E-08 0.0001 3.632E-06 0.0037 4.304E-08 0.0000 Sr-90 6.208E-16 0.0000 5.244E-19 0.0000 0.000E+00 0.0000 2.264E-14 0.0000 2.686E-16 0.0000 7.214E-16 0.0000 1.803E-17 0.0000 Total 9.441E-04 0.9726 1.734E-09 0.0000 0.000E+00 0.0000 1.918E-05 0.0198 1.537E-06 0.0016 5.725E-06 0.0059 1.081E-07 0.0001 Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)
As mrem/yr and Fraction of Total Dose At t = 3.000E+02 years Water Dependent Pathways Water Fish Radon Plant Meat Milk All Pathways*
Radio-Nuclide mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract.
Co-60 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 3.244E-17 0.0000 Cs-134 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Cs-137 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 9.585E-04 0.9875 Ni-63 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.217E-05 0.0125 Sr-90 2.202E-13 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.073E-15 0.0000 9.556E-17 0.0000 1.839E-16 0.0000 2.458E-13 0.0000 Total 2.202E-13 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.073E-15 0.0000 9.556E-17 0.0000 1.839E-16 0.0000 9.706E-04 1.0000
- Sum of all water independent and dependent pathways.
RESRAD, Version 7.0 T1/2 Limit = 30 days 12/06/2014 16:15 Page 17 Summary : Zion Subsurface Soil 100 m^2 120614 File : C:\\RESRAD_FAMILY\\RESRAD\\7.0\\USERFILES\\ZION SUBSURFACE SOIL DCGL.RAD Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)
As mrem/yr and Fraction of Total Dose At t = 1.000E+03 years Water Independent Pathways (Inhalation excludes radon)
Ground Inhalation Radon Plant Meat Milk Soil Radio-Nuclide mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract.
Co-60 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Cs-134 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Cs-137 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Ni-63 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Sr-90 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Total 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)
As mrem/yr and Fraction of Total Dose At t = 1.000E+03 years Water Dependent Pathways Water Fish Radon Plant Meat Milk All Pathways*
Radio-Nuclide mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract.
Co-60 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Cs-134 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Cs-137 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Ni-63 2.432E-08 0.9862 0.000E+00 0.0000 0.000E+00 0.0000 9.815E-11 0.0040 6.519E-12 0.0003 2.367E-10 0.0096 2.466E-08 1.0000 Sr-90 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Total 2.432E-08 0.9862 0.000E+00 0.0000 0.000E+00 0.0000 9.815E-11 0.0040 6.519E-12 0.0003 2.367E-10 0.0096 2.466E-08 1.0000
- Sum of all water independent and dependent pathways.
RESRAD, Version 7.0 T1/2 Limit = 30 days 12/06/2014 16:15 Page 18 Summary : Zion Subsurface Soil 100 m^2 120614 File : C:\\RESRAD_FAMILY\\RESRAD\\7.0\\USERFILES\\ZION SUBSURFACE SOIL DCGL.RAD Dose/Source Ratios Summed Over All Pathways Parent and Progeny Principal Radionuclide Contributions Indicated Parent Product Thread DSR(j,t) At Time in Years (mrem/yr)/(pCi/g)
(i) (j) Fraction 0.000E+00 1.000E+00 3.000E+00 1.000E+01 3.000E+01 1.000E+02 3.000E+02 1.000E+03 Co-60 Co-60 1.000E+00 4.617E+00 4.047E+00 3.110E+00 1.238E+00 8.893E-02 8.844E-06 3.244E-17 0.000E+00 Cs-134 Cs-134 1.000E+00 2.460E+00 1.758E+00 8.978E-01 8.545E-02 1.031E-04 6.286E-15 4.064E-44 0.000E+00 Cs-137+D Cs-137+D 1.000E+00 1.042E+00 1.018E+00 9.717E-01 8.254E-01 5.179E-01 1.013E-01 9.585E-04 0.000E+00 Ni-63 Ni-63 1.000E+00 4.079E-04 4.033E-04 3.943E-04 3.644E-04 2.908E-04 1.309E-04 1.217E-05 2.466E-08 Sr-90+D Sr-90+D 1.000E+00 4.972E-01 4.492E-01 3.666E-01 1.799E-01 1.395E-01 1.877E-04 2.458E-13 0.000E+00 The DSR includes contributions from associated (half-life 30 days) daughters.
Single Radionuclide Soil Guidelines G(i,t) in pCi/g Basic Radiation Dose Limit = 2.500E+01 mrem/yr Nuclide (i) t= 0.000E+00 1.000E+00 3.000E+00 1.000E+01 3.000E+01 1.000E+02 3.000E+02 1.000E+03 Co-60 5.415E+00 6.177E+00 8.037E+00 2.020E+01 2.811E+02 2.827E+06 *1.113E+15 *1.113E+15 Cs-134 1.016E+01 1.422E+01 2.785E+01 2.926E+02 2.425E+05 *1.283E+15 *1.283E+15 *1.283E+15 Cs-137 2.399E+01 2.456E+01 2.573E+01 3.029E+01 4.827E+01 2.467E+02 2.608E+04 *8.593E+13 Ni-63 6.130E+04 6.199E+04 6.340E+04 6.860E+04 8.598E+04 1.910E+05 2.055E+06 1.014E+09 Sr-90 5.028E+01 5.565E+01 6.820E+01 1.390E+02 1.792E+02 1.332E+05 1.017E+14 *1.366E+14
- At specific activity limit Summed Dose/Source Ratios DSR(i,t) in (mrem/yr)/(pCi/g) and Single Radionuclide Soil Guidelines G(i,t) in pCi/g at tmin = time of minimum single radionuclide soil guideline and at tmax = time of maximum total dose = 0.000E+00 years Nuclide Initial tmin DSR(i,tmin) G(i,tmin) DSR(i,tmax) G(i,tmax)
(i) (pCi/g) (years) (pCi/g) (pCi/g)
Co-60 1.000E+00 0.000E+00 4.617E+00 5.415E+00 4.617E+00 5.415E+00 Cs-134 1.000E+00 0.000E+00 2.460E+00 1.016E+01 2.460E+00 1.016E+01 Cs-137 1.000E+00 0.000E+00 1.042E+00 2.399E+01 1.042E+00 2.399E+01 Ni-63 1.000E+00 0.000E+00 4.079E-04 6.130E+04 4.079E-04 6.130E+04 Sr-90 1.000E+00 0.000E+00 4.972E-01 5.028E+01 4.972E-01 5.028E+01
RESRAD, Version 7.0 T1/2 Limit = 30 days 12/06/2014 16:15 Page 19 Summary : Zion Subsurface Soil 100 m^2 120614 File : C:\\RESRAD_FAMILY\\RESRAD\\7.0\\USERFILES\\ZION SUBSURFACE SOIL DCGL.RAD Individual Nuclide Dose Summed Over All Pathways Parent Nuclide and Branch Fraction Indicated Nuclide Parent THF(i) DOSE(j,t), mrem/yr (j) (i) t= 0.000E+00 1.000E+00 3.000E+00 1.000E+01 3.000E+01 1.000E+02 3.000E+02 1.000E+03 Co-60 Co-60 1.000E+00 4.617E+00 4.047E+00 3.110E+00 1.238E+00 8.893E-02 8.844E-06 3.244E-17 0.000E+00 Cs-134 Cs-134 1.000E+00 2.460E+00 1.758E+00 8.978E-01 8.545E-02 1.031E-04 6.286E-15 0.000E+00 0.000E+00 Cs-137 Cs-137 1.000E+00 1.042E+00 1.018E+00 9.717E-01 8.254E-01 5.179E-01 1.013E-01 9.585E-04 0.000E+00 Ni-63 Ni-63 1.000E+00 4.079E-04 4.033E-04 3.943E-04 3.644E-04 2.908E-04 1.309E-04 1.217E-05 2.466E-08 Sr-90 Sr-90 1.000E+00 4.972E-01 4.492E-01 3.666E-01 1.799E-01 1.395E-01 1.877E-04 2.458E-13 0.000E+00 THF(i) is the thread fraction of the parent nuclide.
Individual Nuclide Soil Concentration Parent Nuclide and Branch Fraction Indicated Nuclide Parent THF(i) S(j,t), pCi/g (j) (i) t= 0.000E+00 1.000E+00 3.000E+00 1.000E+01 3.000E+01 1.000E+02 3.000E+02 1.000E+03 Co-60 Co-60 1.000E+00 1.000E+00 8.766E-01 6.737E-01 2.681E-01 1.927E-02 1.917E-06 7.044E-18 0.000E+00 Cs-134 Cs-134 1.000E+00 1.000E+00 7.146E-01 3.650E-01 3.474E-02 4.193E-05 2.560E-15 1.682E-44 0.000E+00 Cs-137 Cs-137 1.000E+00 1.000E+00 9.770E-01 9.326E-01 7.924E-01 4.976E-01 9.763E-02 9.304E-04 7.864E-11 Ni-63 Ni-63 1.000E+00 1.000E+00 9.903E-01 9.710E-01 9.067E-01 7.454E-01 3.756E-01 5.299E-02 5.587E-05 Sr-90 Sr-90 1.000E+00 1.000E+00 9.046E-01 7.403E-01 3.671E-01 4.946E-02 4.442E-05 8.767E-14 2.943E-44 THF(i) is the thread fraction of the parent nuclide.
RESCALC.EXE execution time = 1.88 seconds