Survey Unit Date Scan % Alarms

  1. Samples Sample Results Date Scan %

12112 5/30/2019 100 2

17 systematic, 2 investigation, 4 subsurface 0.179 max OpSOF, 0.018 mean BcSOF 7/30/2019 0

12113 1/18/2019 100 0

17 systematic, 2 subsurface 0.093 max OpSOF, 0.012 mean BcSOF 9/6/2019 10 12203A 2/19/2019 100 0

17 systematic, 14 investigation, 7 subsurface 1.278 max OpSOF, 0.04 mean BcSOF 6/18/2019 1

12203B 2/5/2019 100 0

17 systematic, 2 subsurface 0.159 max OpSOF, 0.014 mean BcSOF 8/1/2019 30 12203C 1/18/2019 100 0

17 systematic, 2 subsurface 0.074 max OpSOF, 0.012 mean BcSOF 8/1/2019 0

12203D 1/18/2019 100 0

17 systematic, 2 subsurface 0.101 max OpSOF, 0.014 mean BcSOF 8/1/2019 0

FSS

Alarms # Samples Sample Results Comments Date Scan % Alarms # Samples N/A 2

below OpDCGL; max Cs-137 5.09E-02 pCi/g Performed after CCDD removal 2/11/2020 0

N/A 0

0 2

no ROC ID Performed after CCDD removal; Focused scan of areas where CCDD was stored or transported 5/26/2020 0

N/A 0

0 8

no ROC ID Performed after CCDD removal; Focused scan of areas where CCDD was stored or transported 5/26/2020 0

N/A 0

0 3

no ROC ID Performed after CCDD removal; Focused scan of areas where CCDD was stored or transported 5/26/2020 0

N/A 0

N/A 1

below OpDCGL; max Cs-137 5.72E-02 pCi/g Performed after CCDD removal 5/26/2020 0

N/A 0

N/A 1

no ROC ID Performed after CCDD removal 1/7/2020 0

4 1st Surveillance

Sample Results Comments Date Scan % Alarms # Samples N/A Visual walkdown for anomalies affecting radiological condition; none identified 6/1/2020 10 0

0 N/A Visual walkdown for anomalies affecting radiological condition; none identified 8/24/2020 5

0 0

N/A Visual walkdown for anomalies affecting radiological condition; none identified 8/24/2020 5

0 0

N/A Visual walkdown for anomalies affecting radiological condition; none identified 8/24/2020 5

0 0

N/A Visual walkdown for anomalies affecting radiological condition; none identified 8/24/2020 5

0 0

no ROC ID

  • Biased scans were performed at erosion areas (small percentage of survey unit);

no anomalies identified.

5/26/2020 0

N/A 0

2nd Surveillance

Sample Results Comments Date Scan % Alarms # Samples N/A Monitoring well removal; no anomalies 8/24/2020 5

0 0

N/A Visual walkdown for anomalies affecting radiological condition; none identified. 5%

of areas during seeding activities N/A Visual walkdown for anomalies affecting radiological condition; none identified. 5%

of areas during seeding activities N/A Visual walkdown for anomalies affecting radiological condition; none identified. 5%

of areas during seeding activities N/A Visual walkdown for anomalies affecting radiological condition; none identified. 5%

of areas during seeding activities N/A Visual walkdown for anomalies affecting radiological condition; none identified 8/24/2020 5

0 0

3rd Surveillance

Sample Results Comments N/A Visual walkdown for anomalies affecting radiological condition; none identified. 5% of areas during seeding activities N/A Visual walkdown for anomalies affecting radiological condition; none identified. 5% of areas during seeding activities 4th Surveillance