ML22279A987
| ML22279A987 | |
| Person / Time | |
|---|---|
| Site: | Zion File:ZionSolutions icon.png (DPR-039, DPR-048) |
| Issue date: | 09/23/2022 |
| From: | Graham J ZionSolutions |
| To: | Office of Nuclear Material Safety and Safeguards |
| Shared Package | |
| ML22279A984 | List: |
| References | |
| ZS-2022-043 | |
| Download: ML22279A987 (158) | |
Text
ZION STATION RESTORATION PROJECT FINAL STATUS SURVEY RELEASE RECORD WASTE WATER TREATMENT FACILITY (WWTF)
SURVEY UNIT 12102 REVISION 1
FSS RELEASE RECORD - REV. 2 NORTH PROTECTED AREA YARD SURVEY UNIT 12201E
~
ZlO"f'tilSOLUTIONS;;;
ME-a:rS..-°""-r PREPAREDBY/ DATE: JeffGraham/~ ~¥-
R iol ical Enginee REVIEWED BY/ DATE:
Robert Yetter ill DigitallysignedbyRobertFYetterlll DN: C=US, O=Energ~uttom;;, CN=Robert F Yetter 111, Robert F Yetter III E-ri;;,ooe..,,~ l,tio~.=
Reason: lhaverevlewedttusdocument Looation:yoursigningloc:ationhere Data:2022-{)9-2608:22:22 Foxit PhantomPOF Version: 9.7 D LT/FSS QA/Documentation Specialist R b rt F Digitally signed by Robert F _ Yetter 0 e DN: C=US, OU=EnergySolutions, CN=Robert F Yetter, E=rfyetter@energysolutions.com Reason: I am the author of this document Yett Location: your signing location here APPROVED BY/ DATE:
Robert Yetter er
~~!~:i~.:'~i~~ib~~;~~1~~:v.o C/L T Manager
[2]
FSS RELEASE RECORD - REV. 1 WASTE WATER TREATMENT FACILITY (WWTF)
SURVEY UNIT 12102
[3]
TABLE OF CONTENTS
- 1.
EXECUTIVE
SUMMARY
................................................................................................... 7
- 2.
SURVEY UNIT DESCRIPTION......................................................................................... 7
- 3.
CLASSIFICATION BASIS.................................................................................................. 8
- 4.
DATA QUALITY OBJECTIVES (DQO)........................................................................... 9
- 5.
SURVEY DESIGN.............................................................................................................. 13
- 6.
SURVEY IMPLEMENTATION........................................................................................ 20
- 7.
SURVEY RESULTS............................................................................................................ 21
- 8.
QUALITY CONTROL....................................................................................................... 28
- 9.
INVESTIGATIONS AND RESULTS............................................................................... 28
- 10. REMEDIATION AND RESULTS..................................................................................... 30
- 11. CHANGES FROM THE SURVEY PLAN....................................................................... 30
- 12. DATA QUALITY ASSESSMENT (DQA)........................................................................ 30
- 13. ANOMALIES....................................................................................................................... 31
- 14. CONCLUSION.................................................................................................................... 31
- 15. REFERENCES.................................................................................................................... 31
- 16. ATTACHMENTS................................................................................................................ 32 ATTACHMENT 1 - FIGURE AND MAPS....................................................................... 33 ATTACHMENT 2 - SCAN DATA..................................................................................... 37 ATTACHMENT 3 - CONSULTATION TRIGGERS FOR RESIDENTIAL AND COMMERCIAL/INDUSTRIAL SOIL CONTAMINATION....... 41 ATTACHMENT 4 - SIGN TEST........................................................................................ 43 ATTACHMENT 5 - QC SAMPLE ASSESSMENT.......................................................... 45 ATTACHMENT 6 - GRAPHICAL PRESENTATIONS................................................. 47 ATTACHMENT 7 - GEL LABS CERTIFICATE OF ANALYSIS REPORTS............. 54
FSS RELEASE RECORD - REV. 1 WASTE WATER TREATMENT FACILITY (WWTF)
SURVEY UNIT 12102
[4]
LIST OF TABLES Table 1 - Dose Significant Radionuclides and Mixture.......................................................................... 10 Table 2 - Base Case DCGLs for Surface Soils (BcDCGLSS)................................................................ 11 Table 3 - Base Case DCGLs for Subsurface Soils (BcDCGLSB).......................................................... 11 Table 4 - Operational DCGLs for Surface Soils (OpDCGLSS)............................................................. 12 Table 5 - Operational DCGLs for Subsurface Soils (OpDCGLSB)....................................................... 12 Table 6 - Surrogate Ratios...................................................................................................................... 13 Table 7 - Investigation Levels................................................................................................................ 15 Table 8 - Systematic Sample Measurement Locations........................................................................... 17 Table 9 - Synopsis of Survey Design..................................................................................................... 19 Table 10 - Instruments and Detectors..................................................................................................... 21 Table 11 - Synopsis of Scan Results....................................................................................................... 21 Table 12 - Summary of Gamma Spectroscopy Results for Surface Soil Samples Comprising the Statistical Sample Population................................................................................................................. 24 Table 13 - Summary of Gamma Spectroscopy Results for Subsurface Soil Samples............................ 25 Table 14 - Surrogate Ratio Analysis Results......................................................................................... 25 Table 15 - Summary of Gamma Spectroscopy Results for QC Soil Samples........................................ 26 Table 16 - Sum-of-Fractions for Individual Surface Soil Samples, when compared to the OpDCGLs (Systematic)............................................................................................................................................ 27 Table 17 - Sum-of-Fractions for Individual Subsurface Soil Samples, when compared to the OpDCGLs
................................................................................................................................................................ 28 Table 18 - Sum-of-Fractions for Individual QC Soil Samples, when compared to the OpDCGLs....... 28 Table 19 - Basic Statistical Properties of Systematic Sample Population.............................................. 28 Table 20 - Summary of Gamma Spectroscopy Results for Investigation Surface and Subsurface Soil Samples................................................................................................................................................... 29 Table 21 - Sum-of-Fractions for Investigation Surface and Subsurface Soil Samples, when compared to the OpDCGLs..................................................................................................................................... 30 LIST OF FIGURES Figure 1 - Class 1 and Class 2 Open Land Survey Units from Figure 2-7 of the LTP............................ 8
FSS RELEASE RECORD - REV. 1 WASTE WATER TREATMENT FACILITY (WWTF)
SURVEY UNIT 12102
[5]
LIST OF ACRONYMS AND ABBREVIATIONS ALARA As Low As Reasonably Achievable AMCG Average Member of the Critical Group BcDCGL Base Case Soil DCGLs C/LT Characterization/License Termination CoC Chain-of-Custody cpm Counts per minute DCGL Derived Concentration Guideline Level DQA Data Quality Assessment DQO Data Quality Objective DRP Discrete Radioactive Particle EMC Elevated Measurement Comparison FOV Field of View FSS Final Status Survey GPS Global Positioning System HTD Hard to Detect HSA Historical Site Assessment IC Insignificant Dose Contributor ISOCS In Situ Object Counting System LBGR Lower Bound of the Gray Region LTP License Termination Plan MARSSIM Multi-Agency Radiation Survey and Site Investigation Manual MDC Minimum Detectable Concentration MDCR Minimum Detectable Count Rate NAD North American Datum NaI Sodium Iodide OpDCGL Operational Derived Concentration Guideline Level OpSOF Operational Sum-of-Fraction QAPP Quality Assurance Project Plan (for Characterization and FSS)
FSS RELEASE RECORD - REV. 1 WASTE WATER TREATMENT FACILITY (WWTF)
SURVEY UNIT 12102
[6]
QC Quality Control RE Radiological Engineer ROC Radionuclides of Concern SOF Sum-of-Fraction TEDE Total Effective Dose Equivalent TSD Technical Support Documents UBGR Upper Bound of the Gray Region VSP Visual Sample Plan ZNPS Zion Nuclear Power Station ZSRP Zion Station Restoration Project
FSS RELEASE RECORD - REV. 1 WASTE WATER TREATMENT FACILITY (WWTF)
SURVEY UNIT 12102
[7]
- 1.
EXECUTIVE
SUMMARY
Final Status Survey (FSS) was performed on this survey unit in August of 2021. Following the completion of this FSS, a concrete foundation structure was found in the survey unit that did not meet the requirement that all remaining structures were to be below 588 grade. Excavations were performed to remove this concrete. Because the geologic features of the survey unit significantly changed during the excavation, the FSS was reperformed following the completion of this work. This release record addresses the results of the reperformance of FSS.
This FSS Release Record for Survey Unit 12102, Waste Water Treatment Facility (WWTF),
has been generated for the Zion Station Restoration Project (ZSRP) in accordance with ZionSolutions procedure ZS-LT-300-001-005, Final Status Survey Data Reporting (Reference 1) and satisfies the requirements of Section 5.11 of the Zion Station Restoration Project License Termination Plan (LTP) (Reference 2).
An FSS package (L1-12102A-F Plan #2) was developed in accordance with ZionSolutions procedure ZS-LT-300-001-001, Final Status Survey Package Development (Reference 3), the ZSRP LTP, and guidance from NUREG-1575, Revision 1, Multi-Agency Radiation Survey and Site Investigation Manual (MARSSIM) (Reference 4).
This open land survey unit has a MARSSIM classification of 1. The survey plan was designed based upon use of the Sign Test as the nonparametric statistical test for compliance. Both the Type I () and Type II () decision error rates were set at 0.05. Eighteen (18) systematic surface soil samples were acquired from the survey unit. In addition, surface scanning was performed on 100% of the total surface area in the survey unit. Numerous latch value readings were recorded in areas with elevated activity identified during the scans. Investigations were performed into the elevated readings. A detailed description of the investigations is included in Section 9. The analytical results for the systematic soil samples taken in Survey Unit 12102 indicate that the Sum-of-Fraction (SOF) for each sample, when compared to the Operational Derived Concentration Guideline Levels (OpDCGL), was less than 1.0, with a maximum Operational SOF (OpSOF) of 0.058. The mean OpSOF for the systematic samples was 0.020.
The mean SOF (BcSOF), when the analytical results were compared to the Base Case DCGLs (BcDCGL), was 0.005, which results in a dose assigned to the survey unit of 0.125 mrem/yr.
Therefore, the null hypothesis is rejected and survey unit 12102 is acceptable for unrestricted release.
- 2.
SURVEY UNIT DESCRIPTION Survey Unit 12102, the Waste Water Treatment Facility (WWTF), is a Class 1 open land survey unit. It is bounded on the west by survey unit 12201E, the south by 12103, the east by 10223, and the north by 12101.
FSS RELEASE RECORD - REV. 1 WASTE WATER TREATMENT FACILITY (WWTF)
SURVEY UNIT 12102
[8]
The boundary of the survey unit was defined using a Global Positioning System (GPS) based on the Illinois State Plane System North American Datum (NAD) 1983 East. The reference coordinates associated with the sample locations in this survey unit are presented in Table 8.
- 3.
CLASSIFICATION BASIS Survey unit 12102 was classified in accordance with ZionSolutions procedure ZS-LT-300-001-002, Survey Unit Classification (Reference 5).
The area encompassing this survey unit was included in two survey units listed in the Historical Site Assessment (HSA): 10101, described as the WWTF Area and 10112, described as the U2 PWST/SST Area. These survey units are identified in Figure 3 of the HSA. Subsequently, in the Zion Station Restoration Project License Termination Plan (LTP), the area of 10112 and 10101 that was inside the Security Area fence line was split into 3 survey units, 12101, 12102, and 12103. The 12102 unit included the area of 10112 north of the PWST and SST, and the south section of 10101, which included the WWTF. The 12102 survey unit was described as the WWTF Facility in Table 2-4 of the LTP. The location of these survey units are represented in Figure 2-7 of the LTP.
Figure 1 - Class 1 and Class 2 Open Land Survey Units from Figure 2-7 of the LTP The initial Final Status Survey of 12102 was completed in March 2019 as a Class 1 survey unit.
This classification remains applicable to this survey design.
FSS RELEASE RECORD - REV. 1 WASTE WATER TREATMENT FACILITY (WWTF)
SURVEY UNIT 12102
[9]
A Radiological Engineer (RE)/Characterization/Licenses Termination (C/LT) Supervisor performed a visual inspection and walk-down of the survey unit on 06/16/2022 prior to performing this FSS. The purpose of the walk-down was to assess the physical condition of the survey unit, evaluate access points and travel paths and identify potentially hazardous conditions.
A final classification assessment was performed in accordance with procedure ZS-LT-300-001-002, Survey Unit Classification as part of the survey design for FSS. The assessment confirmed that Survey Unit 12102 was correctly classified as Class 1.
- 4.
DATA QUALITY OBJECTIVES (DQO)
FSS planning and design hinges on coherence with the Data Quality Objective (DQO) process to ensure, through compliance with explicitly defined inputs and boundaries, that the primary objective of the survey is satisfied. The DQO process is described in the LTP in accordance with MARSSIM. The appropriate design for a given survey is developed using the DQO process as outlined in Appendix D of MARSSIM.
The DQO process incorporated hypothesis testing and probabilistic sampling distributions to control decision errors during data analysis. Hypothesis testing is a process based on the scientific method that compares a baseline condition to an alternate condition. The baseline condition is technically known as the null hypothesis. Hypothesis testing rests on the premise that the null hypothesis is true, and that sufficient evidence must be provided for rejection. In designing the survey plan, the underlying assumption, or null hypothesis was that residual activity in the survey unit exceeded the release criteria. Rejection of the null hypothesis would indicate that residual activity within the survey unit does not exceed the release criteria.
Therefore, the survey unit would satisfy the primary objective of the FSS sample plan.
The primary objective of the FSS sample plan is to demonstrate that the level of residual radioactivity in Survey Unit 12102 does not exceed the release criteria specified in the LTP and that the potential dose from residual radioactivity is As Low As Reasonably Achievable (ALARA).
ZionSolutions Technical Support Document (TSD)11-001, Potential Radionuclides of Concern during the Decommissioning of Zion Station (Reference 7), written in 2012, established the basis for an initial suite of potential ROC for the decommissioning of the Zion Nuclear Power Station (ZNPS).
ZionSolutions TSD 14-019, Radionuclides of Concern for Soil and Basement Fill Model Source Terms (Reference 8), completed in February 2017, was written to refine the initial selection of ROC for decommissioning at ZSRP. The list of ROC was evaluated using Containment Building(s) and Auxiliary Building concrete core analysis data to evaluate the dose significance of each radionuclide in the end state model. Section 4.4 of the TSD evaluated the results of the characterization data of surveys taken of soils. The following conclusion was reached: The results of surface and subsurface soil characterization in the impacted area surrounding Zion
FSS RELEASE RECORD - REV. 1 WASTE WATER TREATMENT FACILITY (WWTF)
SURVEY UNIT 12102
[10]
indicate that there is minimal residual radioactivity in soil. Essentially all of the soil results were reported as non-detectable. Other than Cs-137 at very low levels, and Co-60 at a concentration of 0.24 pCi/g in one sample, the results for all radionuclides were less than MDC. Therefore, the direct determination of radionuclide mixture fractions for initial suite radionuclides in soil is not technically feasible due to the MDC biasing issues discussed above. Based on a generalized assumption that the contaminated water that caused concrete contamination would be similar to the source of soil contamination, the ROC and radionuclide mixture derived for the Auxiliary Building concrete was considered to be reasonably representative of soils for FSS planning and implementation.
The ROC for surface soils are listed in Table 1 below (From Table 5-2 of the LTP):
Table 1 - Dose Significant Radionuclides and Mixture Radionuclide Auxiliary Building
% of Total Activity (normalized)(1)(2)
Co-60 0.92%
Ni-63 23.71%
Sr-90 0.05%
Cs-134 0.01%
Cs-137 75.32%
(1) Based on maximum percent of total activity from Table 20 of TSD 14-019, normalized to one for the dose significant radionuclides (2) Does not include dose significant radionuclides for activated concrete (H-3, Eu-152, Eu-154).
A fundamental precursor to survey design is to establish a relationship between the release criteria and some measurable quantity. This is done through the development of DCGLs. The DCGLs represent average levels of radioactivity above background levels and are presented in terms of surface or mass activity concentrations. Chapter 6 of the LTP describes in detail the modeling used to develop the DCGLs for soils.
Surface soil is defined as soil residing in the first 0.15 m (6 inches) layer of soil. A subsurface soil category, which is defined as a layer of soil beginning at the surface but extending to a depth of 1 m is also assessed to allow for flexibility in compliance demonstration if contamination deeper than 0.15 m is encountered. Site-specific DCGLs for soil were calculated for both the 0.15 m and 1 m thicknesses. Based on characterization data and historical information, there are no expectations of encountering a source term geometry that is comprised of a clean surface layer of soil over a contaminated subsurface soil layer. ZionSolutions TSD 14-011, Soil Area Factors (Reference 9) and LTP Chapter 6, Section 6.8 provides the exposure scenarios and modeling parameters that were used to calculate the site-specific DCGLs for soils (referred to as BcDCGL in this Release Record).
FSS RELEASE RECORD - REV. 1 WASTE WATER TREATMENT FACILITY (WWTF)
SURVEY UNIT 12102
[11]
At ZNPS, compliance is demonstrated through the summation of dose from four distinct source terms for the end-state (basements, soils, buried pipe and groundwater). Basements are comprised of the summation of four structural source terms (surfaces, embedded pipe, penetrations, and fill). When applied to soil, the DCGLs are expressed in units of activity per unit of mass (pCi/g).
The unity rule is applied when there is more than one ROC. The measurement results for each singular ROC present in the mixture are compared against their respective DCGL to derive a dose fraction.
The surface and subsurface soil BcDCGLs for the unrestricted release of open land survey units are listed in Tables 5-5 and 5-6 of the LTP and are provided in Table 2 and Table 3, respectively.
The Insignificant Contributor (IC) dose percentage of 10% was used to adjust the DCGLs in soils to account for the dose from the eliminated IC radionuclides.
Table 2 - Base Case DCGLs for Surface Soils (BcDCGLSS)
Radionuclide Surface Soil DCGL (pCi/g)
Co-60 4.26 Cs-134 6.77 Cs-137 14.18 Ni-63 3,572.10 Sr-90 12.09 Table 3 - Base Case DCGLs for Subsurface Soils (BcDCGLSB)
Radionuclide Subsurface Soil DCGL (pCi/g)
Co-60 3.44 Cs-134 4.44 Cs-137 7.75 Ni-63 763.02 Sr-90 1.66 Each radionuclide-specific Base Case DCGL is equivalent to the level of residual radioactivity (above background levels) that could, when considered independently, result in a Total Effective Dose Equivalent (TEDE) of 25 mrem per year to an Average Member of the Critical Group (AMCG). To ensure that the summation of dose from each source term is 25 mrem/yr or less after all FSS is completed, the BcDCGLs are reduced based on an expected, or a priori, fraction of the 25 mrem/yr dose limit from each source term. The reduced DCGLs, or Operational DCGLs can be related to the BcDCGLs as an expected fraction of dose based on an a priori
FSS RELEASE RECORD - REV. 1 WASTE WATER TREATMENT FACILITY (WWTF)
SURVEY UNIT 12102
[12]
assessment of what the expected dose should be based on the results of site characterization, process knowledge and the extent of planned remediation. The OpDCGL is then used as the DCGL for the FSS design of the survey unit (calculation of surrogate DCGLs, investigations levels, etc.). Details of the OpDCGLs derived for each dose component and the basis for the applied a priori dose fractions are provided in ZionSolutions TSD 17-004, Operational Derived Concentration Guideline Levels for Final Status Survey (Reference 10)
The OpDCGLs for the FSS of surface and subsurface soils are listed in Tables 5-7 and 5-8 of the LTP and are presented in Table 4 and Table 5, respectively.
Table 4 - Operational DCGLs for Surface Soils (OpDCGLSS)
Radionuclide Surface Soil DCGL (pCi/g)
Co-60 1.091 Cs-134 1.733 Cs-137 3.630 Ni-63 914.458 Sr-90 3.095 Table 5 - Operational DCGLs for Subsurface Soils (OpDCGLSB)
Radionuclide Subsurface Soil DCGL (pCi/g)
Co-60 0.881 Cs-134 1.137 Cs-137 1.984 Ni-63 195.333 Sr-90 0.425 In accordance with NUREG-1757, Appendix G, if the HSA indicates that there is no likelihood of substantial subsurface residual radioactivity, subsurface surveys are not necessary. The HSA as well as the results of the extensive characterization of subsurface soils in the impacted area surrounding the Zion facility have shown that there is minimal residual radioactivity in subsurface soil. Consequently, Zion proposes to perform minimal subsurface sampling during FSS.
Instrument DQOs included a verification of the ability of the survey instrument to detect the radiation(s) of interest at the required scan MDC, which for Class 1 Open Land survey units, is the a priori elevated measurement comparison DCGL (DCGLEMC). Survey instrument response checks were required prior to issuance and after the instrument had been used. Control and
FSS RELEASE RECORD - REV. 1 WASTE WATER TREATMENT FACILITY (WWTF)
SURVEY UNIT 12102
[13]
accountability of survey instruments was required to ensure the quality and prevent the loss of data.
As part of the DQOs applied to laboratory processes, analysis results were reported as actual calculated results. The actual recorded value was used as the recorded FSS result for measurement and/or sample values that are less than MDC. Negative values were recorded as zero. Results were not reported as less than MDC. Sample report summaries included unique sample identification, analytical method, radionuclide, result, uncertainty, laboratory data qualifiers, units, and the observed MDC.
In accordance with the LTP, for laboratory analysis, MDCs less than 10% of the Operational DCGL were preferable while MDCs up to 50% of the Operational DCGL were acceptable. The maximum acceptable MDC for measurements obtained using field instruments was the a priori DCGLEMC, which was calculated using the methodology described in the LTP, Section 5.6.4.3.
- 5.
SURVEY DESIGN The level of effort associated with planning a survey is based on the complexity of the survey and nature of the hazards. Guidance for preparing FSS plans is provided in procedure ZS-LT-300-001-001 Final Status Survey Package Development.
The DQO process determined that Co-60, Ni-63, Sr-90, Cs-134 and Cs-137 would be the ROC in survey unit 12102. During FSS, concentrations for HTD ROC Ni-63 and Sr-90 are inferred using a surrogate approach. Cs-137 is the principal surrogate radionuclide for Sr-90 and Co-60 is the principal surrogate radionuclide for Ni-63. The mean, maximum and 95% Upper Confidence Level (UCL) of the surrogate ratios for concrete core samples taken in the Auxiliary Building basement were calculated in ZionSolutions TSD 14-019, Radionuclides of Concern for Soil and Basement Fill Model Source Terms and are presented in Table 6. The maximum ratios will be used in the surrogate calculations during FSS unless area specific ratios are determined by continuing characterization.
Table 6 - Surrogate Ratios Ratios Auxiliary Building Mean Max 95%UCL Ni-63/Co-60 44.143 180.450 154.632 Sr-90/Cs-137 0.001 0.002 0.002 For the FSS of survey unit 12102, the surrogate OpDCGLs for Co-60 and Cs-137 were computed based on the maximum ratios from Table 6. The equation for calculating a surrogate DCGL is as follows:
FSS RELEASE RECORD - REV. 1 WASTE WATER TREATMENT FACILITY (WWTF)
SURVEY UNIT 12102
[14]
Equation 1
=
1
[(
1
) + (
2
- 2) + (
3
- 3) + (
)]
Where:
DCGLSur
=
Surrogate radionuclide DCGL DCGL2,3n
=
DCGL for radionuclides to be represented by the surrogate Rn
=
Ratio of concentration (or nuclide mixture fraction) of radionuclide n to surrogate radionuclide Using the OpDCGLs for surface soils presented in Table 4 and the maximum ratios from Table 6, the following surrogate calculations for surface soils were performed:
Equation 2 (137) =
1
[(
1 3.630(137)) + (
0.002 3.095(90))]
= 3.622 /
The surrogate Op DCGL for surface soils that was used for Cs-137 in this survey unit for direct comparison of surface soil sample results to demonstrate compliance is 3.622 pCi/g.
Equation 3 (60) =
1
[(
1 1.091(60)) + (
180.45 914.458(63))]
= 0.898 /
The surrogate OpDCGL for surface soils that was used for Co-60 in this survey unit for direct comparison of surface soil sample results to demonstrate compliance is 0.898 pCi/g.
Using the BcDCGLs presented in Table 2 and the maximum ratios from Table 6, the following surrogate calculations were performed:
Equation 4 (137) =
1
[(
1 14.18(137)) + (
0.002 12.09(90))]
= 14.15 /
FSS RELEASE RECORD - REV. 1 WASTE WATER TREATMENT FACILITY (WWTF)
SURVEY UNIT 12102
[15]
The surrogate BcDCGL for surface soils that was used for Cs-137 in this survey unit for calculating the DCGLEMC is 14.15 pCi/g.
Equation 5 (60) =
1
[(
1 4.26(60)) + (
180.45 3572.10(63))]
= 3.51 /
The surrogate BcDCGL for surface soils that was used for Co-60 in this survey unit for calculating the DCGLEMC is 3.51 pCi/g.
For this Class 1 open land survey unit, the Investigation Levels for area scanning and soil sample measurement results are those levels specified in LTP Chapter 5, Table 5-25 and are reproduced below in Table 7.
Table 7 - Investigation Levels Classification Scan Investigation Levels Direct Investigation Levels Class 1
>Operational DCGL or >MDCscan if MDCscan is greater than Operational DCGL
> Operational DCGL The MDCscan for the 2350-1/44-10 was calculated using the methodology of TSD-11-004, Ludlum Model 44-10 Detector Sensitivity (Reference 11) with the following parameters:
- background count rate of 5500 counts per minute (cpm)
- scan speed of 0.25 m/sec
- distance from detector to surface of 2
- isotopic mix of 95% Cs-137 and 5% Co-60 The calculated MDCscan value was 2.78 pCi/g, which was greater than the calculated Surrogate DCGLs, therefore the scan investigation level was set at the MDCscan of the 2350-1/44-10. The collimator was not used during the scan surveys.
The Sign Test was selected as the non-parametric statistical test. The use of the Sign Test did not require the selection or use of a background reference area, which simplified survey design and implementation. This approach was conservative since it included background Cs-137 as part of the sample set.
The number of soil samples for FSS was determined in accordance with procedure ZS-LT-300-001-001 Final Status Survey Package Development. The relative shift (/) for the survey unit data set is defined as shift (), which is the Upper Bound of the Gray Region (UBGR), or the DCGL (SOF of 1) minus the Lower Bound of the Gray Region (LBGR) (SOF of 0.5), divided by sigma (), which is the standard deviation of the data set used for survey design. The optimal value for / should range between 1 and 3. The largest value the / can have is 3. If the /
FSS RELEASE RECORD - REV. 1 WASTE WATER TREATMENT FACILITY (WWTF)
SURVEY UNIT 12102
[16]
exceeds 3, then the value of 3 will be used for /. For this survey design, a conservative estimate of the sample variability of 0.30 was used as the coefficient of variation to calculate /.
The calculated relative shift was 1.67. Both the Type I error, or value and the Type II error, or value was set at 0.05. The sample size from Table 5.5 of MARSSIM that equates to the Type I and Type II error of 0.05 for use with the Sign Test is an N value of 17.
The computer program Visual Sample Plan (VSP) was used to generate the sample map, in accordance with ZS-LT-300-001-001. The map used was provided by the Survey Mapping/CAD Specialist, with coordinates based on the NAD standard topographical grid coordinate system.
VSP generated a map with 18 sample points. Systematic sample numbers 1 to 17 were used in the previous FSS, therefore the systematic samples for this FSS were 201 to 218. The Prospective Power Curve generated by VSP showed adequate power for the survey design.
In accordance with Section 5.6.4.3 of the LTP, the a priori DCGLEMC values were calculated for the gamma emitting ROC to ensure that the MDCSCAN of the selected instrument was sufficient to detect small areas of elevated activity in the survey unit. The calculations were:
- To calculate the area bounded by the systematic samples: =
=
2024 18 = 112.4 2
- From the LTP, Table 5-16, the Area Factors for the next larger area, 100 m2 area were used:
o Cs-137 - 1.46 o Cs-134 - 1.16 o Co 1.30
- The DCGLEMC is the Surrogate Base Case DCGL times the Area Factor:
o The DCGLEMC for Cs-137 = 1.46 14.15 = 20.66 /
o The DCGLEMC for Cs-134 - 1.30 6.77 = 8.71 /
o The DCGLEMC for Co 1.16 3.51 = 4.07 /
The calculated MDCSCAN, 2.78 pCi/g, is less than the DCGLEMC values calculated above, therefore, the spacing of the statistical systematic sampling and measurement locations was adequate to detect small areas of elevated radioactivity. No adjustment to the sample number was required.
The implementation of quality control measures as referenced by LTP Chapter 5, Section 5.9 and ZionSolutions ZS-LT-01, Quality Assurance Project Plan (for Characterization and FSS) (QAPP) (Reference 12) includes the collection of a soil sample for split sample analysis on 5% of the soil samples taken in a survey unit with the locations selected at random.
One (1) surface soil sample, L1-12102A-FQGS-205-SS was selected randomly for split sample analysis for the FSS of this survey unit.
In accordance with Section 5.7.1.6.2 of the LTP, a subsurface soil sample was taken at 10%
of the systematic surface soil sample locations in the survey unit with the location(s) selected at random. Locations L1-12102A-FSGS-210-SB and L1-12102A-FSGS-211-SB were
FSS RELEASE RECORD - REV. 1 WASTE WATER TREATMENT FACILITY (WWTF)
SURVEY UNIT 12102
[17]
selected for this survey unit.
The locations of the eighteen (18) systematic samples are listed in Table 8. Note, samples were numbered starting with 201. This is because systematic samples were collected in a previous FSS of this survey unit. A map of the systematic sample locations is included in.
Table 8 - Systematic Sample Measurement Locations MEASUREMENT ID NORTHING (meters)
EASTING (meters)
L1-12102A-FSGS-201-SS 641825.42 343797.69 L1-12102A-FSGS-202-SS 641825.42 343809.42 L1-12102A-FSGS-203-SS 641835.58 343756.65 L1-12102A-FSGS-204-SS 641835.58 343768.37 L1-12102A-FSGS-205-SS 641835.58 343780.10 L1-12102A-FSGS-206-SS 641835.58 343791.83 L1-12102A-FSGS-207-SS 641835.58 343803.55 L1-12102A-FSGS-208-SS 641835.58 343815.28 L1-12102A-FSGS-209-SS 641845.73 343750.78 L1-12102A-FSGS-210-SS 641845.73 343762.51 L1-12102A-FSGS-211-SS 641845.73 343774.24 L1-12102A-FSGS-212-SS 641845.73 343785.96 L1-12102A-FSGS-213-SS 641845.73 343797.69 L1-12102A-FSGS-214-SS 641845.73 343809.42 L1-12102A-FSGS-215-SS 641855.89 343756.65 L1-12102A-FSGS-216-SS 641855.89 343768.37 L1-12102A-FSGS-217-SS 641855.89 343780.10 L1-12102A-FSGS-218-SS 641855.89 343791.83 ZSRP LTP Chapter 5, Section 5.1 states that soil samples will be collected during FSS to confirm the HTD to surrogate radionuclide ratios (Table 6). Ten percent (10%) of the FSS samples collected from open land survey units will be analyzed for HTD ROC. Only HTD radionuclides included as ROC (Ni-63 and Sr-90 for soils) will be analyzed in the FSS confirmatory samples. For soil samples with positive results for both a HTD ROC and the corresponding surrogate radionuclide (Cs-137 or Co-60), the HTD surrogate ratio will be derived and compared against the maximum ratio (see Table 6). The maximum ratios (Table
- 6) will be used unless specific survey information supports the use of a surrogate ratio that is specific to the area. In these cases, the survey unit-specific radiological data and the derived surrogate ratios will be submitted to the NRC for approval. If approved, then the survey unit-specific ratios used and the survey data serving as the basis for the surrogate ratios will be documented in the release record for the survey unit.
In addition, LTP Chapter 5, Section 5.1 states that if levels of residual gamma radioactivity in
FSS RELEASE RECORD - REV. 1 WASTE WATER TREATMENT FACILITY (WWTF)
SURVEY UNIT 12102
[18]
an individual soil sample exceed an OpSOF of 0.1, then the sample(s) will be analyzed for HTD ROC.
Two (2) investigation soil samples exceeded an OpSOF of 0.1. An additional investigation soil sample was also chosen to be analyzed for HTD. Each sample was sent off-site (GEL Laboratories) for HTD analysis as specified in the FSS Sample Plan. The following samples were selected:
- 1. L1-12102A-FIGS-201-SB
- 2. L1-12102A-FIGS-202-SS
- 3. L1-12002A-FIGS-206-SS Table 9 provides a synopsis of the survey design for survey unit 12102.
FSS RELEASE RECORD - REV. 1 WASTE WATER TREATMENT FACILITY (WWTF)
SURVEY UNIT 12102
[19]
Table 9 - Synopsis of Survey Design FEATURE DESIGN CRITERIA BASIS Survey Unit Area 2,024 m2 GPS measurements of area Number of Surface Soil Samples 18 (Systematic)
- = 0.30
- UBGR = SOF of 1
- LBGR = SOF of 0.5
- Type I error = 0.05
- Type II error = 0.05
- / = 1.67 (MARSSIM Table 5.5)
Grid Spacing 11.4 m (LTP Chapter 5, Section 5.6.4.5.2)
DCGLs
- Co 1.091 pCi/g
- Cs-134 - 1.733 pCi/g
- Cs-137 - 3.630 pCi/g
- Ni 914.458 pCi/g
- Sr 3.095 pCi/g Operational DCGLs for Surface Soils, (LTP Chapter 5, Table 5-7)
HTD Analysis A minimum of two (2) soil samples selected for HTD ROC analysis (LTP Chapter 5, section 5.1)
Measurement Investigation Level Operational DCGL (LTP Chapter 5, Table 5-25)
Scan Survey Area Coverage 100%
(LTP Chapter 5, Table 5-24)
QC One (1) surface soil sample selected randomly for split sample analysis (LTP Chapter 5, Section 5.9)
Number of Subsurface Soil Samples Two (2) systematic surface soil sample locations selected randomly (LTP Chapter 5, Section 5.7.1.6.2)
FSS RELEASE RECORD - REV. 1 WASTE WATER TREATMENT FACILITY (WWTF)
SURVEY UNIT 12102
[20]
- 6.
SURVEY IMPLEMENTATION Survey instructions for this FSS were incorporated into and performed in accordance with FSS Sample Plan L1-12102-F Plan #2, which was developed in accordance with ZionSolutions procedure ZS-LT-300-001-001, Final Status Survey Package Development. The FSS unit was inspected and controlled in accordance with ZionSolutions procedure ZS-LT-300-001-003, Isolation and Control for Final Status Survey (Reference 13).
For survey unit 12102, compliance with the unrestricted release criteria was demonstrated through a combination of surface scanning with a Ludlum Model 44-10 gamma detector and the sampling of surface soil for isotopic analysis. In accordance with the LTP Chapter 5, two (2) subsurface samples were obtained. Also, if during the performance of FSS, the analysis of a surface soil sample, or the results of a surface gamma scan indicated the potential presence of residual radioactivity at a concentration of 75% of the subsurface Operational DCGL, then a biased subsurface soil sample(s) would be taken to the appropriate depth within the area of concern as part of the investigation. This threshold was encountered during the FSS of survey unit 12102 during the surface scans. Numerous scan alarms were recorded during the gamma walkover survey. The areas showing activity above the Action Level were marked. Investigation soil samples were taken. A detailed discussion of these surveys/samples are included in Section 9 (Investigations and Results).
FSS field activities were conducted under FSS Sample Plan L1-12102-F Plan #2. A Field Log (ZS-LT-300-001-001 Attachment 14) was used to document field activities and other information pertaining to the performance of the FSS.
FSS field activities were projected to take four (4) working days to complete. Daily briefings were conducted to discuss the expectations for job performance and to review safety aspects of the job. The survey required field activities were performed during normal working hours starting on June 20, 2022, and concluding on July 11, 2022.
The eighteen (18) systematic surface soil sample locations were measured, using XY coordinates provided by VSP, from the southwest corner of the survey unit and marked with flags.
Gamma scans were performed on 100% of the surface area of the survey unit using a Ludlum 2350-1 paired with a Model 44-10 (2x 2) NaI detector operated in the rate-meter mode and using audio response. The probe was positioned within 2 to the ground and was moved at a scan speed of approximately 0.25 meters per second. Numerous areas of elevated activity were detected on the scans (see Section 9 for further discussion). Daily prior to use and daily following use, each detector was subjected to an Operational Response Check in accordance with procedure ZS-RP-108-004-011, Operation of the Ludlum Model 2350-1 Data Logger (Reference 14).
The Daily Operational Response Check compared the background response and the response to check sources ranges established for normal background and detector source response to ensure that the detector was working properly.
FSS RELEASE RECORD - REV. 1 WASTE WATER TREATMENT FACILITY (WWTF)
SURVEY UNIT 12102
[21]
The instruments and detectors used for this survey are presented in Table 10. The instruments and detectors were verified to be properly calibrated prior to use.
Table 10 - Instruments and Detectors Instrument/Detector Type Serial #
Calibration Due Date Ludlum 2350-1/Ludlum 44-10 117578/PR157372 11/04/2022 Ludlum 2350-1/Ludlum 44-10 126209/PR192598 11/04/2022 Ludlum 2350-1/Ludlum 44-10 304718/PR363311 6/07/2023 Ludlum 2350-1/Ludlum 44-10 216188/RN25063 11/04/2022 In accordance with the survey design, eighteen (18) surface soil samples were collected at the designated systematic sample points. In addition, two (2) subsurface samples and one (1) QC sample were collected at the randomly selected systematic sample locations. Eight (8)
Investigation soil samples were collected at locations identified as elevated activity on the surface scans: six (6) surface samples, one (1) QC surface sample and one (1) subsurface sample.
Three (3) samples were selected for HTD radionuclide analysis.
- 7.
SURVEY RESULTS One hundred percent (100%) of the surface of the survey unit was scanned for elevated radiation levels. Sixty-nine (69) 1-m wide scan rows, as shown on the map in Attachment 1, were marked in the field and scanned with the 2350-1/44-10 using latching mode. Readings were recorded at approximately 10-meter intervals during the scans. Numerous elevated measurement locations were identified by surface scan. Table 11 provides an overview of the scan results. Complete scan results are provided in Attachment 2.
Table 11 - Synopsis of Scan Results Scan Row Highest Logged Reading Action Level(1)
- of Scan Alarms Investigation Samples (cpm)
(cpm) 1 6138 6218 0
2 5996 6218 0
3 6148 6218 0
4 6135 6218 0
5 7941 6218 1
6 6166 6218 0
7 7898 6218 1
8 8533 6218 2
L1-12102A-FIGS-206-SS
FSS RELEASE RECORD - REV. 1 WASTE WATER TREATMENT FACILITY (WWTF)
SURVEY UNIT 12102
[22]
Table 11 (continued) - Synopsis of Scan Results Scan Row Highest Logged Reading Action Level(1)
- of Scan Alarms Investigation Samples (cpm)
(cpm) 9 8244 6218 1
10 8146 6218 2
11 8133 6218 3
12 x
Note 2 13 8556 6240 14 8952 6240 15 9713 6240 16 9281 6240 17 9944 6281 18 x
6281 19 x
6281 20 9323 6281 21 x
6281 22 x
6281 23 9731 6281 24 x
6250 25 9826 6250 26 x
6250 27 10363 6250 28 x
6250 29 x
6250 30 x
6250 31 8505 6281 32 x
6281 33 x
6281 34 9784 6281 35 x
6281 36 x
6281 37 x
6281 38 9319 6080 39 10213 6080 L1-12102A-FIGS-204-SS 40 x
6080 41 x
6080 42 x
6080 43 x
6080
FSS RELEASE RECORD - REV. 1 WASTE WATER TREATMENT FACILITY (WWTF)
SURVEY UNIT 12102
[23]
Table 11 (continued) - Synopsis of Scan Results Scan Row Highest Logged Reading Action Level(1)
- of Scan Alarms Investigation Samples (cpm)
(cpm) 44 x
6080 Note 2 45 x
6080 46 9483 6080 47 x
6080 48 x
6080 49 8770 6080 50 9545 6282 51 6282 52 9859 6282 53 9757 6282 54 9961 6282 L1-12102A-FIGS-203-SS 55 x
6282 56 x
6282 57 x
6282 58 6026 6282 0
59 5257 5406 0
60 6132 6138 0
61 6100 6138 0
62 6103 6138 0
63 10436 6138 1
L1-12102A-FIGS-201-SS, L1-12102A-FIGS-202-SS particle found/captured 64 6074 6138 0
65 5737 6138 0
66 5542 6138 0
67 5843 5891 0
68 5654 5891 0
69 5877 5891 0
Note 1: The action level is based on the measurement Minimum Detectable Count Rate (MDCR) plus background in accordance with the FSS plan Note 2: The entire area of rows 12 through 57 was above the ASP. Only the high readings throughout this area were recorded.
Eighteen (18) systematic surface soil samples taken for non-parametric statistical testing, six (6) investigation soil samples, two (2) QC soil samples, and three (3) subsurface soil samples were sent off-site to be analyzed by GEL Laboratories. Summaries of the sample analysis results for the systematic sample population are provided in Tables 12 and 13, respectively. The basic statistics for the systematic sample population are summarized in Table 19. The gamma spectroscopy results revealed two (2) samples with activity levels above MDA for Cs-137, two (2) samples with an activity level above MDA for Co-60 and no samples with activity levels
FSS RELEASE RECORD - REV. 1 WASTE WATER TREATMENT FACILITY (WWTF)
SURVEY UNIT 12102
[24]
above MDA for Cs-134. The concentration for Ni-63 and Sr-90 are inferred based on the maximum ratios as specified in Table 6. The mean of the gamma spectroscopic analysis results for the sample population indicated that Cs-137 was present at levels lower than the concentrations of Cs-137 expected to be found in off-site soil in the vicinity of the ZNPS as presented in ZionSolutions TSD 13-004, Examination of Cs-137 Global Fallout in Soils at Zion Station (Reference 15). The complete gamma spectroscopy reports are presented in Attachment
- 8.
Table 12 - Summary of Gamma Spectroscopy Results for Surface Soil Samples Comprising the Statistical Sample Population MEASUREMENT ID Co-60(1)
Cs-134(1)
Cs-137(1)
Ni-63(2)
Sr-90(2)
(pCi/g)
(pCi/g)
(pCi/g)
(pCi/g)
(pCi/g)
L1-12102A-FSGS-201-SS 2.04E-02 6.04E-02 0.00E+00 3.68E+00 0.00E+00 L1-12102A-FSGS-202-SS 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 L1-12102A-FSGS-203-SS 1.11E-02 0.00E+00 0.00E+00 2.00E+00 0.00E+00 L1-12102A-FSGS-204-SS 1.76E-02 3.75E-02 3.67E-03 3.18E+00 7.34E-06 L1-12102A-FSGS-205-SS 1.85E-02 3.71E-02 3.48E-03 3.34E+00 6.96E-06 L1-12102A-FSGS-206-SS 1.11E-02 1.09E-04 1.97E-02 2.00E+00 3.94E-05 L1-12102A-FSGS-207-SS 0.00E+00 2.21E-02 5.06E-03 0.00E+00 1.01E-05 L1-12102A-FSGS-208-SS 2.04E-03 0.00E+00 1.13E-01 3.68E-01 2.26E-04 L1-12102A-FSGS-209-SS 1.58E-03 3.68E-03 9.34E-03 2.85E-01 1.87E-05 L1-12102A-FSGS-210-SS 2.37E-02 2.74E-03 0.00E+00 4.28E+00 0.00E+00 L1-12102A-FSGS-211-SS 2.18E-02 5.63E-03 0.00E+00 3.93E+00 0.00E+00 L1-12102A-FSGS-212-SS 7.06E-03 2.44E-03 0.00E+00 1.27E+00 0.00E+00 L1-12102A-FSGS-213-SS 0.00E+00 1.53E-02 0.00E+00 0.00E+00 0.00E+00 L1-12102A-FSGS-214-SS 5.41E-03 0.00E+00 1.01E-03 9.76E-01 2.02E-06 L1-12102A-FSGS-215-SS 5.26E-03 1.47E-02 8.09E-04 9.49E-01 1.62E-06 L1-12102A-FSGS-216-SS 0.00E+00 1.05E-02 1.88E-02 0.00E+00 3.76E-05 L1-12102A-FSGS-217-SS 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 L1-12102A-FSGS-218-SS 4.28E-03 2.15E-03 0.00E+00 7.72E-01 0.00E+00 Note:
(1) Bold font indicates ROC positively detected at concentration greater than MDC.
(2) Ni-63 and Sr-90 are inferred concentrations using the maximum HTD ratio.
FSS RELEASE RECORD - REV. 1 WASTE WATER TREATMENT FACILITY (WWTF)
SURVEY UNIT 12102
[25]
Table 13 - Summary of Gamma Spectroscopy Results for Subsurface Soil Samples MEASUREMENT ID Co-60(1)
Cs-134(1)
Cs-137(1)
Ni-63(2)
Sr-90(2)
(pCi/g)
(pCi/g)
(pCi/g)
(pCi/g)
(pCi/g)
L1-12102A-FSGS-210-SB 0.00E+00 1.70E-02 0.00E+00 0.00E+00 0.00E+00 L1-12102A-FSGS-211-SB 0.00E+00 6.34E-02 1.13E-02 0.00E+00 2.26E-05 Note:
(1) Bold font indicates ROC positively detected at concentration greater than MDC.
(2) Ni-63 and Sr-90 are inferred concentrations using the maximum HTD ratio.
The off-site laboratory, GEL Laboratories, processed a total of three (3) investigation samples selected for HTD ROC analysis. Two (2) samples were selected for having an OpSOF > 0.1. The following samples were selected:
- 1. L1-12102A-FIGS-201-SB
- 2. L1-12102A-FIGS-202-SS
- 3. L1-12102A-FIGS-206-SS Calculations of the surrogate ratios listed in Table 6 for HTD radionuclides included as ROC (Ni-63 and Sr-90 for soils) are included in the following table. All analyses met the required MDC. Only Cs-137 and Co-60 were positively detected in two of the samples at a concentration greater than MDC. Consequently, comparison of existing ratios verses the maximum ratios from Table 6 was not required. The results are provided in Table 14.
Table 14 - Surrogate Ratio Analysis Results Sample # L1-12102A-FIGS-201-SB ROC Result Uncertainty MDC
>MDC (pCi/g)
(pCi/g)
(pCi/g)
Co-60 8.69E-01 1.12E-01 4.78E-02 Yes Cs-134 9.42E-03 4.19E-02 7.91E-02 No Cs-137 6.73E-02 4.71E-02 5.81E-02 Yes Ni-63 2.99E+00 4.71E+00 7.98E+00 No Sr-90
-3.74E-03 2.07E-02 3.97E-02 No Sample # L1-12102A-FIGS-202-SS ROC Result Uncertainty MDC
>MDC (pCi/g)
(pCi/g)
(pCi/g)
Co-60 1.10E-01 4.15E-02 3.55E-02 Yes Cs-134
-1.56E-03 1.91E-02 3.63E-02 No Cs-137 4.62E-02 3.36E-02 3.51E-02 Yes Ni-63 1.42E+00 5.23E+00 8.98E+00 No Sr-90 1.56E-02 2.10E-02 3.57E-02 No
FSS RELEASE RECORD - REV. 1 WASTE WATER TREATMENT FACILITY (WWTF)
SURVEY UNIT 12102
[26]
Table 14 (continued) Surrogate Ratio Analysis Results Sample # L1-12102A-FIGS-206-SS ROC Result Uncertainty MDC
>MDC (pCi/g)
(pCi/g)
(pCi/g)
-1.02E-02 1.97E-02 3.64E-02 No Cs-134 3.15E-02 3.97E-02 3.15E-02 No Cs-137 2.31E-02 2.48E-02 2.31E-02 No Ni-63
-4.36E-02 5.00E+00 8.68E+00 No Sr-90
-9.85E-03 1.74E-02 3.44E-02 No The implementation of survey specific QC measures included the collection of one (1) systematic sample (L1-12102A-FQGS-205-SS) and one (1) biased sample (L1-12102A-QIGS-205-SS) for split sample analysis. GEL Laboratories analyzed the designated QC samples. Gamma spectroscopy results (summarized in Table 15) indicate that the concentration for the ROC were less than MDC in both samples. The concentration for Ni-63 and Sr-90 are inferred based on the maximum ratios as specified in Table 6.
Table 15 - Summary of Gamma Spectroscopy Results for QC Soil Samples MEASUREMENT ID Co-60(1)
Cs-134(1)
Cs-137(1)
Ni-63(2)
Sr-90(2)
(pCi/g)
(pCi/g)
(pCi/g)
(pCi/g)
(pCi/g)
L1-12102A-FQGS-205-SS 2.32E-02 5.86E-03 0.00E+00 4.19E+00 0.00E+00 L1-12102A-QIGS-205-SS 0.00E+00 3.71E-02 1.78E-02 0.00E+00 3.56E-05 Note:
(1) Bold font indicates ROC positively detected at concentration greater than MDC.
(2) Ni-63 and Sr-90 are inferred concentrations using the maximum HTD ratio.
The sample plan also directed that 5% of the survey unit area be surveyed for QC by gamma walkover scans, with the area to be selected by the RE.
Areas selected for the QC scan consisted of rows that identified scan readings above the Action Level for the survey. QC scan surveys were documented on survey 22-0142. The area covered was 120 m2, 5.9% of the survey unit.
The results of the QC scan were in agreement with the initial scans.
The SOF or unity rule is the mathematical test used to evaluate compliance with radiological criteria for license termination when more than one radionuclide has been determined to be potentially present. The equation for the unity rule is:
Equation 6
FSS RELEASE RECORD - REV. 1 WASTE WATER TREATMENT FACILITY (WWTF)
SURVEY UNIT 12102
[27]
Where:
Cn
= concentration of radionuclide n DCGLn
= DCGL of radionuclide n.
The results of the unity rule calculation for the ROC in the systematic sample population when compared against the OpDCGLs for surface soils for survey unit 12102 are provided in Table
- 16. The results of the unity rule calculation for the ROC for the subsurface samples are provided in Table 17 and the results for the QC sample are presented in Table 18.
Table 16 - Sum-of-Fractions for Individual Surface Soil Samples, when compared to the OpDCGLs (Systematic)
MEASUREMENT ID Fraction of the OpDCGLs for Surface Soils OpSOF Co-60 Cs-134 Cs-137 Ni-63 Sr-90 L1-12102A-FSGS-201-SS 1.87E-02 3.49E-02 0.00E+00 4.03E-03 0.00E+00 0.058 L1-12102A-FSGS-202-SS 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.000 L1-12102A-FSGS-203-SS 1.02E-02 0.00E+00 0.00E+00 2.19E-03 0.00E+00 0.012 L1-12102A-FSGS-204-SS 1.61E-02 2.16E-02 1.01E-03 3.47E-03 2.37E-06 0.042 L1-12102A-FSGS-205-SS 1.70E-02 2.14E-02 9.59E-04 3.65E-03 2.25E-06 0.043 L1-12102A-FSGS-206-SS 1.02E-02 6.29E-05 5.43E-03 2.19E-03 1.27E-05 0.018 L1-12102A-FSGS-207-SS 0.00E+00 1.28E-02 1.39E-03 0.00E+00 3.27E-06 0.014 L1-12102A-FSGS-208-SS 1.87E-03 0.00E+00 3.11E-02 4.03E-04 7.30E-05 0.033 L1-12102A-FSGS-209-SS 1.45E-03 2.12E-03 2.57E-03 3.12E-04 6.04E-06 0.006 L1-12102A-FSGS-210-SS 2.17E-02 1.58E-03 0.00E+00 4.68E-03 0.00E+00 0.028 L1-12102A-FSGS-211-SS 2.00E-02 3.25E-03 0.00E+00 4.30E-03 0.00E+00 0.028 L1-12102A-FSGS-212-SS 6.47E-03 1.41E-03 0.00E+00 1.39E-03 0.00E+00 0.009 L1-12102A-FSGS-213-SS 0.00E+00 8.83E-03 0.00E+00 0.00E+00 0.00E+00 0.009 L1-12102A-FSGS-214-SS 4.96E-03 0.00E+00 2.78E-04 1.07E-03 6.53E-07 0.006 L1-12102A-FSGS-215-SS 4.82E-03 8.48E-03 2.23E-04 1.04E-03 5.23E-07 0.015 L1-12102A-FSGS-216-SS 0.00E+00 6.06E-03 5.18E-03 0.00E+00 1.21E-05 0.011 L1-12102A-FSGS-217-SS 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.000 L1-12102A-FSGS-218-SS 3.92E-03 1.24E-03 0.00E+00 8.45E-04 0.00E+00 0.006 Systematic Measurements Number of Systematic Measurements =
18
- of Systematic Measurements with OpSOF > 1 =
0
- of Systematic Measurements with OpSOF > 0.1 (HTD Assessment) =
0 Max Individual Systematic Measurement OpSOF =
0.0576 Mean Systematic Measurement OpSOF =
0.0196 1
2 2
1 1
+
+
DCGL C
DCGL C
DCGL C
n n
FSS RELEASE RECORD - REV. 1 WASTE WATER TREATMENT FACILITY (WWTF)
SURVEY UNIT 12102
[28]
Table 17 - Sum-of-Fractions for Individual Subsurface Soil Samples, when compared to the OpDCGLs MEASUREMENT ID Fraction of the OpDCGLs for Subsurface Soils OpSOF Co-60 Cs-134 Cs-137 Ni-63 Sr-90 L1-12102A-FSGS-210-SB 0.00E+00 1.50E-02 0.00E+00 0.00E+00 0.00E+00 0.015 L1-12102A-FSGS-211-SB 0.00E+00 3.66E-02 3.11E-03 0.00E+00 7.30E-06 0.040 Table 18 - Sum-of-Fractions for Individual QC Soil Samples, when compared to the OpDCGLs MEASUREMENT ID Fraction of the OpDCGLs for Surface soils OpSOF Co-60 Cs-134 Cs-137 Ni-63 Sr-90 L1-12102A-FQGS-205-SS 2.63E-02 5.15E-03 0.00E+00 2.14E-02 0.00E+00 0.053 L1-12102A-QIGS-205-SS 0.00E+00 2.14E-02 4.90E-03 0.00E+00 1.15E-05 0.026 Table 19 - Basic Statistical Properties of Systematic Sample Population ROC Mean Median Max Min Std. Dev.
BcDCGL Avg. SOF Avg. Dose (pCi/g)
(pCi/g)
(pCi/g)
(pCi/g)
(pCi/g) per ROC Per ROC Co-60 8.56E-03 5.41E-03 2.37E-02 0.00E+00 0.009 4.26 2.01E-03 5.02E-02 Cs-134 1.25E-02 3.68E-03 6.04E-02 0.00E+00 0.017 6.77 1.84E-03 4.61E-02 Cs-137 1.03E-02 8.09E-04 1.13E-01 0.00E+00 0.027 14.18 7.25E-04 1.81E-02 Ni-63 1.54E+00 9.76E-01 4.28E+00 0.00E+00 1.575 3572.1 4.33E-04 1.08E-02 Sr-90 2.06E-05 1.62E-06 2.26E-04 0.00E+00 0.000 12.09 1.70E-06 4.25E-05 The mean BcSOF for survey unit 12102 is 0.005 which equates to a dose of 0.125 mrem/yr TEDE.
The mean of all identified isotopes is less than the Consultation Triggers for Residential and Commercial/Industrial Soil Contamination depicted in Table H.1 of NUREG 1757, Vol.1, Rev.
2 (MOU Table 1). The full table is included in Attachment 3 of this Release Record.
- 8.
QUALITY CONTROL GEL laboratories processed two (2) split samples, L1-12102A-FQGS-205-SS and L1-12102A-QIGS-205-SS using gamma spectroscopy analysis. The data was evaluated using acceptance criteria specified in ZionSolutions procedure ZS-LT-01. There was acceptable agreement between field split results. Refer to Attachment 5 for data and quality control analysis results.
- 9.
INVESTIGATIONS AND RESULTS An investigation was performed at the location of a scan alarm in row #63. A DRP was suspected due to the reading appearing to be a point source of activity. A field gamma spec reading taken with the Inspector 1000 identified Co-60. A DRP was identified and captured. The DRP read 304k cpm. Two (2) soil samples, L1-12102A-FIGS-201-SB and L1-12102A-FIGS-202-SS also showed positive activity for Co-60, with Cs-134 and Cs-137 < MDA. It was suspected that this
FSS RELEASE RECORD - REV. 1 WASTE WATER TREATMENT FACILITY (WWTF)
SURVEY UNIT 12102
[29]
activity was also a small DRP in the sample. Additional soil was collected at the sample point, and at four (4) locations located 0.5m to the north, south, east, and west of the initial sample.
Surface and subsurface samples were collected at each point, with the soil from each sample being scanned in a 1 layer with the 2350-1/44-10. No additional DRPs were identified. In accordance with the protocols for DRP survey, the samples were not submitted for isotopic analysis.
The center of the survey unit, from rows 12 to 57, was uniformly above the ASP. The north and south section of rows 5 to 11 also had areas above the ASP. The FSS Technicians were directed to perform a 100% scan of these rows, collecting latch values at the points of highest activity.
Thirty-one (31) latch readings were recorded, with readings from 7898 cpm to 10363 cpm. Field gamma spec readings were taken at each latched location using the Inspector 1000. No plant related nuclides were identified. Eleven (11) of the systematic samples were located within this area. An additional four (4) investigation samples were taken in this area (L1-12102A-FIGS-203-SS through L1-12102A-FIGS-206-SS). The results of the fifteen (15) samples taken in this area showed one (1) sample with positive activity for Cs-137, with an OpSOF of 0.04. The results of the other samples were < MDA for the ROC.
Table 20 - Summary of Gamma Spectroscopy Results for Investigation Surface and Subsurface Soil Samples MEASUREMENT ID Co-60(1)
Cs-134(1)
Cs-137(1)
Ni-63(2)
Sr-90(2)
(pCi/g)
(pCi/g)
(pCi/g)
(pCi/g)
(pCi/g)
L1-12102A-FIGS-201-SS 1.67E-02 0.00E+00 1.54E-02 3.01E+00 3.08E-05 L1-12102A-FIGS-201-SB 8.54E-01 1.61E-03 1.43E-02 1.54E+02 2.86E-05 L1-12102A-FIGS-202-SS 1.32E-01 4.23E-02 2.68E-02 2.38E+01 5.36E-05 L1-12102A-FIGS-203-SS 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 L1-12102A-FIGS-204-SS 1.70E-02 1.47E-02 9.79E-03 3.07E+00 1.96E-05 L1-12102A-FIGS-205-SS 2.27E-02 4.88E-02 2.98E-02 4.10E+00 5.96E-05 L1-12102A-FIGS-206-SS 5.92E-03 3.81E-02 4.04E-02 1.07E+00 8.08E-05 Note:
(1) Bold font indicates ROC positively detected at concentration greater than MDC.
(2) Ni-63 and Sr-90 are inferred concentrations using the maximum HTD ratio.
FSS RELEASE RECORD - REV. 1 WASTE WATER TREATMENT FACILITY (WWTF)
SURVEY UNIT 12102
[30]
Table 21 - Sum-of-Fractions for Investigation Surface and Subsurface Soil Samples, when compared to the OpDCGLs MEASUREMENT ID Fraction of the OpDCGLs for Surface and Subsurface Soils OpSOF Co-60 Cs-134 Cs-137 Ni-63 Sr-90 L1-12102A-FIGS-201-SS 1.53E-02 0.00E+00 4.24E-03 3.30E-03 9.95E-06 0.023 L1-12102A-FIGS-201-SB 9.69E-01 1.42E-03 7.21E-03 7.89E-01 6.73E-05 1.767 L1-12102A-FIGS-202-SS 1.21E-01 2.44E-02 7.38E-03 2.60E-02 1.73E-05 0.179 L1-12102A-FIGS-203-SS 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.000 L1-12102A-FIGS-204-SS 1.56E-02 8.48E-03 2.70E-03 3.35E-03 6.33E-06 0.030 L1-12102A-FIGS-205-SS 2.08E-02 2.82E-02 8.21E-03 4.48E-03 1.93E-05 0.062 L1-12102A-FIGS-206-SS 5.43E-03 2.20E-02 1.11E-02 1.17E-03 2.61E-05 0.040
- 10.
REMEDIATION AND RESULTS A DRP was identified and removed in row #63. The results of investigation samples taken at this location also showed positive Co-60 activity, suspected to also be from a DRP. Additional investigations showed no additional DRP activity in the soil.
- 11.
CHANGES FROM THE SURVEY PLAN None.
- 12.
DATA QUALITY ASSESSMENT (DQA)
The DQO sample design and data were reviewed in accordance with ZionSolutions procedure ZS-LT-300-001-004, Final Status Survey Data Assessment (Reference 16) for completeness and consistency. Documentation was complete and legible. Surveys and sample collection were consistent with the DQOs. The sampling design had adequate power as indicated by the Retrospective Power Curve.
The analytical results of all samples, with the exception of L1-12102A-FIGS-201-SB, were less than a SOF of one when compared to the Operational DCGLs. It was suspected that this activity was a DRP contained in the sample. Additional investigation surveys determined that there was no additional DRP activity at that location.
Although MARSSIM states that the Sign Test need not be performed in the instance that no measurements surpass the DCGL, the test was conducted to demonstrate coherence to the statistical principles of the DQO process. The Sign Test was performed on the data and compared to the original assumptions of the DQOs. The evaluation of the Sign Test results demonstrates that the survey unit passes the unrestricted release criteria, thus, the null hypothesis is rejected.
The Sign Test is included in Attachment 4.
FSS RELEASE RECORD - REV. 1 WASTE WATER TREATMENT FACILITY (WWTF)
SURVEY UNIT 12102
[31]
The preliminary data review consisted of calculating basic statistical quantities (e.g., mean, median, standard deviation). All data was considered valid including negative values, zeros, values reported below the MDC, and values with uncertainties greater than two standard deviations. The mean and median values for each ROC were well below the respective Operational DCGLs. Also, the retrospective power curve shows that a sufficient number of samples were collected to achieve the desired power. Therefore, the survey unit meets the unrestricted release criteria with adequate power as required by the DQOs.
The data for Co-60 and Cs-137 is represented graphically through a frequency plot and a quantile plot. All graphical representations are provided in Attachment 6.
- 13.
ANOMALIES None.
- 14.
CONCLUSION Survey unit 12102 has met the DQOs of the FSS plan. The ALARA criteria for soils as specified in Chapter 4 of the LTP were achieved. The EMC for soils was not needed for this survey unit.
All identified ROC were used for statistical testing to determine the adequacy of the survey unit for FSS. Evaluation of the data shows that none of the ROC concentration values exceeds the Operational DCGL, therefore, in accordance with the LTP Section 5.10, the survey unit meets the release criterion.
The sample data passed the Sign Test. The null hypothesis was rejected. The Retrospective Power Curve showed that adequate power was achieved.
The mean BcSOF, when the analytical results were compared to the BcDCGLs, was 0.005, which results in a dose contribution from soil in survey unit 12102 of 0.125 mrem/yr. based on the average concentration of the ROC in samples used for non-parametric statistical sampling.
The conclusion of this Release Record is that survey unit 12102 is acceptable for unrestricted release.
- 15.
REFERENCES
- 1. ZionSolutions procedure ZS-LT-300-001-005, Final Status Survey Data Reporting
- 2. Zion Station Restoration Project License Termination Plan (LTP)
- 3. ZionSolutions procedure ZS-LT-300-001-001, Final Status Survey Package Development
- 4. NUREG-1575, Revision 1, Multi-Agency Radiation Survey and Site Investigation Manual (MARSSIM)
FSS RELEASE RECORD - REV. 1 WASTE WATER TREATMENT FACILITY (WWTF)
SURVEY UNIT 12102
[32]
- 5. ZionSolutions procedure ZS-LT-300-001-002, Survey Unit Classification
- 6. Zion Station Historical Site Assessment (HSA)
- 7. ZionSolutions TSD 11-001, Potential Radionuclides of Concern during the Decommissioning of Zion Station
- 8. ZionSolutions TSD 14-019, Radionuclides of Concern for Soil and Basement Fill Model Source Terms
- 9. ZionSolutions TSD 14-011, Soil Area Factors
- 10. ZionSolutions TSD 17-004, Operational Derived Concentration Guideline Levels for Final Status Survey
- 11. ZionSolutions TSD 11-004, Ludlum Model 44-10 Detector Sensitivity
- 12. ZionSolutions procedure ZS-LT-01, Quality Assurance Project Plan (QAPP) for Characterization and Final Status Survey
- 13. ZionSolutions procedure ZS-LT-300-001-003, Isolation and Control for Final Status Survey
- 14. ZionSolutions procedure ZS-RP-108-004-011, Operation of the Ludlum Model 2350-1 Data Logger
- 15. ZionSolutions TSD 13-004, Examination of Cs-137 Global Fallout in Soils at Zion Station
- 16. ZionSolutions procedure ZS-LT-300-001-004, Final Status Survey Data Assessment
- 16.
ATTACHMENTS
- 1. Attachment 1 - Figure and Maps
- 2. Attachment 2 - Scan Data
- 3. Attachment 3 - Consultation Triggers for Residential and Commercial/Industrial Soil Contamination
- 4. Attachment 4 - Sign Test
- 5. Attachment 5 - QC Sample Assessment
- 6. Attachment 6 - Graphical Presentations
- 7. Attachment 7 - GEL Labs Certificate of Analysis Reports
FSS RELEASE RECORD - REV. 1 WASTE WATER TREATMENT FACILITY (WWTF)
SURVEY UNIT 12102
[33]
ATTACHMENT 1 - FIGURE AND MAPS
FSS RELEASE RECORD - REV. 1 WASTE WATER TREATMENT FACILITY (WWTF)
SURVEY UNIT 12102
[34]
Survey Unit 12102 Final Status Survey Boundaries and Systematic Sample Points
FSS RELEASE RECORD - REV. 1 WASTE WATER TREATMENT FACILITY (WWTF)
SURVEY UNIT 12102
[35]
Survey Unit 12102 Final Status Survey Scan Rows
FSS RELEASE RECORD - REV. 1 WASTE WATER TREATMENT FACILITY (WWTF)
SURVEY UNIT 12102
[36]
Survey Unit 12102 Composite Scan Map (with elevated reading latch locations and investigation sample locations)
FSS RELEASE RECORD - REV. 1 WASTE WATER TREATMENT FACILITY (WWTF)
SURVEY UNIT 12102
[37]
ATTACHMENT 2 - SCAN DATA
FSS RELEASE RECORD - REV. 1 WASTE WATER TREATMENT FACILITY (WWTF)
SURVEY UNIT 12102
[38]
Detector Type Detector ID M2350-1 ID Survey Unit Location Date/Time Scan Logged Result Avg
Background
Action Level Scan Alarms (cpm)
(cpm)
(cpm) 44-10 PR157372 117578 12102 GS001 6/20/2022 8:31 6138 5430 6218 No 44-10 PR157372 117578 12102 GS001 6/20/2022 8:36 6044 5430 6218 No 44-10 PR157372 117578 12102 GS001 6/20/2022 8:39 5674 5430 6218 No 44-10 PR157372 117578 12102 GS002 6/20/2022 8:43 5502 5430 6218 No 44-10 PR157372 117578 12102 GS002 6/20/2022 8:47 5996 5430 6218 No 44-10 PR157372 117578 12102 GS002 6/20/2022 8:52 5882 5430 6218 No 44-10 PR157372 117578 12102 GS003 6/20/2022 8:57 6115 5430 6218 No 44-10 PR157372 117578 12102 GS003 6/20/2022 9:02 6076 5430 6218 No 44-10 PR157372 117578 12102 GS003 6/20/2022 9:06 6148 5430 6218 No 44-10 PR157372 117578 12102 GS004 6/20/2022 9:11 6018 5430 6218 No 44-10 PR157372 117578 12102 GS004 6/20/2022 9:18 5979 5430 6218 No 44-10 PR157372 117578 12102 GS004 6/20/2022 9:25 6135 5430 6218 No 44-10 PR157372 117578 12102 GS005 6/20/2022 9:27 7941 5430 6218 Yes 44-10 PR157372 117578 12102 GS005 6/20/2022 9:42 5753 5430 6218 No 44-10 PR157372 117578 12102 GS005 6/20/2022 9:47 5779 5430 6218 No 44-10 PR157372 117578 12102 GS005 6/20/2022 9:52 5965 5430 6218 No 44-10 PR157372 117578 12102 GS006 6/20/2022 9:56 5837 5430 6218 No 44-10 PR157372 117578 12102 GS006 6/20/2022 10:00 6166 5430 6218 No 44-10 PR157372 117578 12102 GS006 6/20/2022 10:04 6036 5430 6218 No 44-10 PR157372 117578 12102 GS007 6/20/2022 10:08 5706 5430 6218 No 44-10 PR157372 117578 12102 GS007 6/20/2022 10:12 5996 5430 6218 No 44-10 PR157372 117578 12102 GS007 6/20/2022 10:19 7898 5430 6218 Yes 44-10 PR157372 117578 12102 GS008 6/20/2022 10:24 8318 5430 6218 Yes 44-10 PR157372 117578 12102 GS008 6/20/2022 10:29 6174 5430 6218 No 44-10 PR157372 117578 12102 GS008 6/20/2022 10:35 8533 5430 6218 Yes 44-10 PR157372 117578 12102 GS009 6/20/2022 13:26 5642 5430 6218 No 44-10 PR157372 117578 12102 GS009 6/20/2022 13:31 6191 5430 6218 No 44-10 PR157372 117578 12102 GS009 6/20/2022 13:39 8244 5430 6218 Yes 44-10 PR157372 117578 12102 GS010 6/20/2022 13:43 8146 5430 6218 Yes 44-10 PR157372 117578 12102 GS010 6/20/2022 13:50 6198 5430 6218 No 44-10 PR157372 117578 12102 GS010 6/20/2022 13:56 7501 5430 6218 Yes 44-10 PR157372 117578 12102 GS011 6/20/2022 14:00 7257 5430 6218 Yes 44-10 PR157372 117578 12102 GS011 6/20/2022 14:08 8133 5430 6218 Yes 44-10 PR157372 117578 12102 GS011 6/20/2022 14:16 7577 5430 6218 Yes 44-10 PR192598 126209 12102 GS013 6/23/2022 10:33 8556 5450 6240 Yes 44-10 PR192598 126209 12102 GS014 6/23/2022 13:21 8952 5450 6240 Yes
FSS RELEASE RECORD - REV. 1 WASTE WATER TREATMENT FACILITY (WWTF)
SURVEY UNIT 12102
[39]
Detector Type Detector ID M2350-1 ID Survey Unit Location Date/Time Scan Logged Result Avg
Background
Action Level Scan Alarms (cpm)
(cpm)
(cpm) 44-10 PR192598 126209 12102 GS015 6/23/2022 13:43 9713 5450 6240 Yes 44-10 PR192598 126209 12102 GS016 6/23/2022 14:16 9281 5450 6240 Yes Scan of rows 13 to 16.
All of the area of these rows is above the ASP.
The high readings in the area were latched.
44-10 PR192598 126209 12102 GS017 6/24/2022 9:16 9632 5489 6281 Yes 44-10 PR192598 126209 12102 GS017 6/24/2022 9:30 9944 5489 6281 Yes 44-10 PR192598 126209 12102 GS020 6/24/2022 10:28 9323 5489 6281 Yes 44-10 PR192598 126209 12102 GS023 6/24/2022 13:25 9731 5489 6281 Yes Scan of rows 17 to 23.
All of the area of these rows is above the ASP.
The high readings in the area were latched.
44-10 PR192598 126209 12102 GS025 6/25/2022 8:08 9826 5460 6250 Yes 44-10 PR192598 126209 12102 GS027 6/25/2022 8:40 10363 5460 6250 Yes Scan of rows 24 to 30.
All of the area of these rows is above the ASP.
The high readings in the area were latched.
44-10 PR192598 126209 12102 GS031 6/27/2022 13:41 8505 5489 6281 Yes 44-10 PR192598 126209 12102 GS034 6/27/2022 14:16 8835 5489 6281 Yes 44-10 PR192598 126209 12102 GS034 6/27/2022 14:21 9784 5489 6281 Yes Scan of rows 31 to 37.
All of the area of these rows is above the ASP.
The high readings in the area were latched.
44-10 PR192598 126209 12102 GS038 6/29/2022 8:50 9319 5302 6080 Yes 44-10 PR192598 126209 12102 GS039 6/29/2022 9:06 10213 5302 6080 Yes 44-10 PR192598 126209 12102 GS046 6/29/2022 13:50 9483 5302 6080 Yes 44-10 PR192598 126209 12102 GS049 6/29/2022 14:28 8770 5302 6080 Yes Scan of rows 38 to 49.
All of the area of these rows is above the ASP.
The high readings in the area were latched.
44-10 PR363311 304718 12102 GS050 6/29/2022 8:55 9545 5490 6282 Yes 44-10 PR363311 304718 12102 GS052 6/29/2022 9:37 9859 5490 6282 Yes 44-10 PR363311 304718 12102 GS053 6/29/2022 10:33 9757 5490 6282 Yes 44-10 PR363311 304718 12102 GS054 6/29/2022 13:11 9961 5490 6282 Yes All of the area of rows 50 to 57 is above the ASP.
The high readings in the area were latched.
44-10 PR363311 304718 12102 GS058 6/29/2022 14:26 5746 5490 6282 No 44-10 PR363311 304718 12102 GS058 6/29/2022 14:30 6026 5490 6282 No 44-10 PR363311 304718 12102 GS058 6/29/2022 14:35 5277 5490 6282 No
FSS RELEASE RECORD - REV. 1 WASTE WATER TREATMENT FACILITY (WWTF)
SURVEY UNIT 12102
[40]
Detector Type Detector ID M2350-1 ID Survey Unit Location Date/Time Scan Logged Result Avg
Background
Action Level Scan Alarms (cpm)
(cpm)
(cpm) 44-10 PR363311 304718 12102 GS059 6/29/2022 15:56 5081 4675 5406 No 44-10 PR363311 304718 12102 GS059 6/29/2022 16:00 5257 4675 5406 No 44-10 PR363311 304718 12102 GS059 6/29/2022 16:05 5116 4675 5406 No 44-10 RN25063 216188 12102 GS060 6/30/2022 8:50 5975 5356 6138 No 44-10 RN25063 216188 12102 GS060 6/30/2022 8:57 6132 5356 6138 No 44-10 RN25063 216188 12102 GS060 6/30/2022 9:06 5858 5356 6138 No 44-10 RN25063 216188 12102 GS061 6/30/2022 9:17 6100 5356 6138 No 44-10 RN25063 216188 12102 GS061 6/30/2022 9:27 5843 5356 6138 No 44-10 RN25063 216188 12102 GS061 6/30/2022 9:33 6074 5356 6138 No 44-10 RN25063 216188 12102 GS062 6/30/2022 9:40 6034 5356 6138 No 44-10 RN25063 216188 12102 GS062 6/30/2022 9:46 5939 5356 6138 No 44-10 RN25063 216188 12102 GS062 6/30/2022 9:52 6103 5356 6138 No 44-10 RN25063 216188 12102 GS063 6/30/2022 9:58 5897 5356 6138 No 44-10 RN25063 216188 12102 GS063 6/30/2022 10:03 5556 5356 6138 No 44-10 RN25063 216188 12102 GS063 6/30/2022 10:20 10436 5356 6138 Yes 44-10 RN25063 216188 12102 GS064 6/30/2022 14:51 6074 5356 6138 No 44-10 RN25063 216188 12102 GS064 6/30/2022 14:59 5844 5356 6138 No 44-10 RN25063 216188 12102 GS064 6/30/2022 15:06 5819 5356 6138 No 44-10 RN25063 216188 12102 GS065 6/30/2022 15:13 5376 5356 6138 No 44-10 RN25063 216188 12102 GS065 6/30/2022 15:18 5464 5356 6138 No 44-10 RN25063 216188 12102 GS065 6/30/2022 15:23 5737 5356 6138 No 44-10 RN25063 216188 12102 GS066 6/30/2022 15:53 5542 5356 6138 No 44-10 RN25063 216188 12102 GS066 6/30/2022 15:59 5484 5356 6138 No 44-10 RN25063 216188 12102 GS066 6/30/2022 16:04 5410 5356 6138 No 44-10 RN25063 216188 12102 GS067 7/1/2022 8:21 5381 5125 5891 No 44-10 RN25063 216188 12102 GS067 7/1/2022 8:30 5833 5125 5891 No 44-10 RN25063 216188 12102 GS067 7/1/2022 8:43 5843 5125 5891 No 44-10 RN25063 216188 12102 GS068 7/1/2022 8:53 5392 5125 5891 No 44-10 RN25063 216188 12102 GS068 7/1/2022 9:02 5654 5125 5891 No 44-10 RN25063 216188 12102 GS068 7/1/2022 9:09 5559 5125 5891 No 44-10 RN25063 216188 12102 GS069 7/1/2022 9:16 5877 5125 5891 No 44-10 RN25063 216188 12102 GS069 7/1/2022 9:23 5714 5125 5891 No 44-10 RN25063 216188 12102 GS069 7/1/2022 9:28 5686 5125 5891 No
FSS RELEASE RECORD - REV. 1 WASTE WATER TREATMENT FACILITY (WWTF)
SURVEY UNIT 12102
[41]
ATTACHMENT 3 - CONSULTATION TRIGGERS FOR RESIDENTIAL AND COMMERCIAL/INDUSTRIAL SOIL CONTAMINATION
FSS RELEASE RECORD - REV. 1 WASTE WATER TREATMENT FACILITY (WWTF)
SURVEY UNIT 12102
[42]
Table H.1
~
ZIONSOLUTIONSuc
Consultation Triggers for Residential and Commercial/Industrial Soil Contamination (MOU Table 1)
M~SIIMioM~
Except for radium-226, thorium-232, or total uranium, concentrations should be aggregated using a sum of the fraction approach to determine site-specific consultation trigger concentrations. This table is based on single contaminant concentrations for residential and commercial/industrial land use when using generally accepted exposure parameters. Table users should select the appropriate column based on the site's reasonably anticipated land use.
Radionuclide Residential Soil Concentration Industrial/Commercial Soil Concentration H-3 228 nCj/g 423 oCi/g C-14 46 oCi/g 123 000 oCi/J!;
Na-22 9oCL'g 14 pCi/g S-35 19,600 pCi/g 32,200 000 oCi/2 Cl-36 6oCi/J!;
10,700 pCi/g Ca-45 13.500 pCi/J!;
3 740 000 oCi/e:
Sc-46 105 Dl i/g 169 oCiig Mn-54 69 oCi/g 112 oCi/1!:
Fe-55 269 000 oCi/g 2 210,000 oCi/g Co-57 873 oCi/g 1,420 pCi/J!;
Co-60 4 pCi/g 6 pCi/2 Ni-59 20 800 oCi/g 1,230 000 oCi/2 Ni-63 9480 oCi/g 555 000 oCi/g Sr-90+D 23 oCi/g 1.070 oCi/g Nb-94 2 pCi/g 3 pCi/g Tc-99 25 pCi/g 89,400 pCi/g 1-129 60 oCi/g 1,080 oCi/g Cs-134 16 oCi/g 26 oCi/g Cs-137+D 6 oCi/g 11 oCi/g Eu-152 4 oCi/g 7 oCi/2 Eu-154 S pCi/g 8 pCi/g lr-192 336 pCi/g 544 pCi/g Pb-210+D IS oCi/g 123 oCi/g Ra-226 S oCi/2 S oCi/g Ac-227+D 10 oCi/g 21 oCi/2 Th-228+D 15 oCi/g 25 oCi/g Th-232 5 pCi/g 5 pCi/g U-234 401 oCi/g 3 310 oCi/2 U-235+D 20 oCi/g 39 oCi/2 U-238+D 74 oCi/g 179 oCili!:
total uranium 47 m2/k2 1230 m2/kg Pu-231!
297 pCi/g 1 640 pCi/2 Pu-239 259 pCi/g 1,430 oCi/g Pu-241 40 600 oCi/g 172.000 ne i/2 Am-241 187 oCi/g 568 pCi/2 Cm-242 32 200 oCi/g 344 000 pCi/g Cm-243 35 pCi/g 67 pCi/g
FSS RELEASE RECORD - REV. 1 WASTE WATER TREATMENT FACILITY (WWTF)
SURVEY UNIT 12102
[43]
ATTACHMENT 4 - SIGN TEST
~
ZIONSOLUTIONS;;z
An E.-gySolutions Company
PSS RELEASE RECORD - REV. 1
~
WASTE WATER TREATMENT FACILITY (WWTF)
SURVEY UNIT 12102
ZIO SOLUTIONS,--;-
Mt.
s.-,,,,.~
Survey Al'ea:
'O.
1 000 De. cl'iption: Secmity Restricted Area Ground Sm*vey l.7nit:
No.
1 1210 A De *cl'iption: Wa te Water Treatment Facility (WWTF)
Clas ification:
T. 1>e I (a) Error:
0.0_
umber of Sample :
18 Fraction of the Release Criterion Radionuclides of Concem ActiYity or Weighted 1-W 5 Sign OF Sum 01'1s)
Co-60 Cs-134 Cs-137 Ni-63 Sr-90 (as applicable")
1 1.87E-02 3.49E-02 0.00E+00 4.03E-03 0.00E+00 SOF 0.058 0.942
+
2 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 SOF 0.000 1.000
+
3 1.02£-02 0.00E+00 0.0OE+00 2.19E-03 0.00E+00 SOF 0.012 0.988
+
4 1.61E-02 2.16E-02 1.0lE-03 3.47£-03 2.37E-06 SOF 0.042 0.958
+
5 1.70E-02 2.14E-02 9.59E-04 3.65E-03 2.25E-06 SOF 0.043 0.957
+
6 1.02E-02 6.29E-05 5.43E-03 2.19E-03 1.27E-05 SOF 0.018 0.982
+
7 0.00E+00 1.28E-02 1.39E-03 0.00E+00 3.27E-06 SOF 0.014 0.986
+
8 1.87£-03 0.00E+00 3.llE-02 4.03E-04 7.30E-05 SOF 0.033 0.967
+
9 1.45E-03 2.12E-03 2.57E-03 3.12E-04 6.04E-06 SOF 0.006 0.994
+
10 2.17E-02 1.58E-03 0.00E+00 4.68E-03 0.00E+00 SOF 0.028 0.972
+
11 2.00E-02 3.25E-03 0.00E+00 4.30E-03 0.00E+00 SOF 0.028 0.972
+
12 6.47E-03 1.41E-03 0.00E+00 1.39E-03 0.00E+00 SOF 0.009 0.991
+
13 0.00E+00 8.83E-03 0.00E+00 0.00E+00 0.00E+00 SOF 0.009 0.991
+
14 4.96E-03 0.00E+00 2.78E-04 l.07E-03 6.53E-07 SOF 0.006 0.994
+
15 4.82E-03 8.48E-03 2.23E-04 1.04E-03 5.23E-07 SOF 0.015 0.985
+
16 0.00E+00 6.06E-03 5.18E-03 0.00E+00 1.21E-05 SOF 0.011 0.989
+
17 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 SOF 0.000 1.000
+
18 3.92E-03 l.24E-03 0.00E+00 8.45E-04 0.00E+00 SOF 0.006 0.994
+
C1itical Value (Table I.3 of 1ARSSIM) =
12 umber of Posith-e Difference ( +) =
18 The mYey unit 0 (meets D (doe
- not meet the acceptance criteria. ----
Prepared By (RE):
I ame)
(Sign ure)
Digitally slgned byRo FYetterlll Robert F Yetter J 11
~::';;;:.'.I;.;'~'::!.., tloo,.C Mf"""'y"""'*'*,fyottoril@oo*sl""'l,tloM.rom p
R d B {RE)
Location:your aigning locationhere eer ev,ewe y
~::=i~a
2~~=mt6~~=:i~=
9 : 9=.7
.o ________
(Print Name)
(Signa ure)
(Dat e)
[44]
FSS RELEASE RECORD - REV. 1 WASTE WATER TREATMENT FACILITY (WWTF)
SURVEY UNIT 12102
[45]
ATTACHMENT 5 - QC SAMPLE ASSESSMENT
~
ZIONSOLUTIONS;;z
An E.-gySolutions Company
PSS RELEASE RECORD - REV. 1 WASTE WATER TREATMENT FACILITY (WWTF)
SURVEY UNIT 12102 Duplicate Sample Assessment Form Ll-1210- A*F
~
=ZIO SOLUTIQ S,-;-=-
.-. (.
~
oUected from ru.uple location tig-ation 1
1a pe tro cop 1ple C01 uuent
- A
. and Ll-1-10 Re *olnti 1.llE 00 16.-t9 greemeut Ra1ge
- 0. _-1.33 0.6-1.66 For both *ru.nple pair *. the tru.1dard *ample and QC *ru.uple did not both h~n-e a po iti\*e re ult for a gru.nma emitti.n° ROC. therefore the K-
-tO
- as 1 *ed
- ep able a~ *ee 1e1 t
[46]
1.95£+01 Re *oh i01
<-t 4-
-t:
16-_ 0 51--00
> 00 0.94 Date:
ceptable I
O,_ -1.0 0.6-1.66
- 0.
-1.33
- 0. 0-1.__
0,8_ -1.1 y
FSS RELEASE RECORD - REV. 1 WASTE WATER TREATMENT FACILITY (WWTF)
SURVEY UNIT 12102
[47]
ATTACHMENT 6 - GRAPHICAL PRESENTATIONS
FSS RELEASE RECORD - REV. 1 WASTE WATER TREATMENT FACILITY (WWTF)
SURVEY UNIT 12102
[48]
Posting Plot
FSS RELEASE RECORD - REV. 1 WASTE WATER TREATMENT FACILITY (WWTF)
SURVEY UNIT 12102
[49]
QUANTILE PLOT FOR Co-60 Survey Unit: 12102 Survey Unit Name: Waste Water Treatment Facility (WWTF)
Mean:
8.23E-03 pCi/g 0.00E+00 5.00E-03 1.00E-02 1.50E-02 2.00E-02 2.50E-02 0%
20%
40%
60%
80%
100%
Concentration (pCi/g)
Percentage Quantile Plot For Co-60
FSS RELEASE RECORD - REV. 1 WASTE WATER TREATMENT FACILITY (WWTF)
SURVEY UNIT 12102
[50]
QUANTILE PLOT FOR Cs-137 Survey Unit: 12102 Survey Unit Name: Waste Water Treatment Facility (WWTF)
Mean:
9.71E-03 pCi/g 0.00E+00 2.00E-02 4.00E-02 6.00E-02 8.00E-02 1.00E-01 1.20E-01 0%
20%
40%
60%
80%
100%
Concentration (pCi/g)
Percentage Quantile Plot For Cs-137
FSS RELEASE RECORD - REV. 1 WASTE WATER TREATMENT FACILITY (WWTF)
SURVEY UNIT 12102
[51]
HISTOGRAM FOR Co-60 Survey Unit: 12102 Survey Unit Name: Waste Water Treatment Facility (WWTF)
Mean:
8.32E-03 pCi/g Median:
5.34E-03 pCi/g ST DEV:
0.009 Skew:
0.659 Upper Value Observation Frequency Observation 3.95E-03 7
39%
7.90E-03 4
22%
1.19E-02 2
11%
1.58E-02 0
0%
1.98E-02 2
11%
2.37E-02 3
17%
TOTAL 18 100%
7 4
2 0
2 3
0 1
2 3
4 5
6 7
8 9
10 3.95E-03 7.90E-03 1.19E-02 1.58E-02 1.98E-02 2.37E-02 Frequency Upper End Value (pCi/g)
Frequency Plot For Co-60
FSS RELEASE RECORD - REV. 1 WASTE WATER TREATMENT FACILITY (WWTF)
SURVEY UNIT 12102
[52]
HISTOGRAM FOR Cs-137 Survey Unit: 12102 Survey Unit Name: Waste Water Treatment Facility (WWTF)
Mean:
9.71E-03 pCi/g Median:
4.05E-04 pCi/g ST DEV:
0.027 Skew:
3.882 Upper Value Observation Frequency Observation 1.88E-02 16 89%
3.77E-02 1
6%
5.65E-02 0
0%
7.53E-02 0
0%
9.42E-02 0
0%
1.13E-01 1
6%
TOTAL 18 100%
16 1
0 0
0 1
0 2
4 6
8 10 12 14 16 18 20 1.88E-02 3.77E-02 5.65E-02 7.53E-02 9.42E-02 1.13E-01 Frequency Upper End Value (pCi/g)
Frequency Plot For Cs-137
FSS RELEASE RECORD - REV. 1 WASTE WATER TREATMENT FACILITY (WWTF)
SURVEY UNIT 12102
[53]
Prospective and Retrospective Power Curves for Survey Unit 12112 0
0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1
1.1 1.2 1.3 1.4 1.5 1.6 1.7 1.8 1.9 2
0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1
True OpSOF Mean or Median Probability of deciding true mean or median < A.L.
MARSSIM Sign Test (Pro\Retrospective) Power alpha=5% n=(17\18) std.dev.=(0.3\0.016)
Prospective Power Retrospective Power
FSS RELEASE RECORD - REV. 1 WASTE WATER TREATMENT FACILITY (WWTF)
SURVEY UNIT 12102
[54]
ATTACHMENT 7 - GEL LABS CERTIFICATE OF ANALYSIS REPORTS
August 30, 2022 Mr. Gerry Wood Zion Solutions 100 Shiloh Blvd.
Zion, Illinois 60099 Re: Zion Solutions Work Order: 590180
Dear Mr. Wood:
GEL Laboratories, LLC (GEL) appreciates the opportunity to provide the enclosed analytical results for the sample(s) we received on July 22, 2022. This original data report has been prepared and reviewed in accordance with GELs standard operating procedures.
Test results for NELAP or ISO 17025 accredited tests are verified to meet the requirements of those standards, with any exceptions noted. The results reported relate only to the items tested and to the sample as received by the laboratory. These results may not be reproduced except as full reports without approval by the laboratory.
Copies of GELs accreditations and certifications can be found on our website at www.gel.com.
Our policy is to provide high quality, personalized analytical services to enable you to meet your analytical needs on time every time. We trust that you will find everything in order and to your satisfaction. If you have any questions, please do not hesitate to call me at (843) 556-8171, ext. 1605.
Sincerely, PM_SIGN_HERE Zachary Worsham Project Manager Purchase Order: 702793 Enclosures Page 1 of 44 SDG: 590180
July 20, 2022 Mr. Gerry Wood Zion Solutions 100 Shiloh Blvd.
Zion, Illinois 60099 Re: Zion Solutions Work Order: 586069
Dear Mr. Wood:
GEL Laboratories, LLC (GEL) appreciates the opportunity to provide the enclosed analytical results for the sample(s) we received on July 14, 2022. This original data report has been prepared and reviewed in accordance with GELs standard operating procedures.
Test results for NELAP or ISO 17025 accredited tests are verified to meet the requirements of those standards, with any exceptions noted. The results reported relate only to the items tested and to the sample as received by the laboratory. These results may not be reproduced except as full reports without approval by the laboratory.
Copies of GELs accreditations and certifications can be found on our website at www.gel.com.
Our policy is to provide high quality, personalized analytical services to enable you to meet your analytical needs on time every time. We trust that you will find everything in order and to your satisfaction. If you have any questions, please do not hesitate to call me at (843) 556-8171, ext. 1605.
Sincerely, PM_SIGN_HERE Zachary Worsham Project Manager Purchase Order: 702793 Enclosures Page 1 of 60 SDG: 586069 Marcellas Knight for
Reviewed by USER_SIGN_HERE GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 (843) 5568171 www.gel.com Certificate of Analysis Report ENRG080 Zion Solutions (702793)
Client SDG: 586069 GEL Work Order: 586069 Where the analytical method has been performed under NELAP certification, the analysis has met all of the requirements of the NELAC standard unless qualified on the Certificate of Analysis.
The designation ND, if present, appears in the result column when the analyte concentration is not detected above the limit as defined in the U qualifier above.
This data report has been prepared and reviewed in accordance with GEL Laboratories LLC standard operating procedures. Please direct any questions to your Project Manager, Zachary Worsham.
The Qualifiers in this report are defined as follows:
- A quality control analyte recovery is outside of specified acceptance criteria
- Analyte is a Tracer compound
UI Gamma SpectroscopyUncertain identification for Page 2 of 60 SDG: 586069
Certificate of Analysis GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Rad Gamma Spec Analysis Parameter Result Units Qualifier Analyst Date Time Gammaspec, Gamma, Solid (Requested List) "Dry Weight Corrected" 2290065 1019 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g Actinium-228 Bismuth-211 Bismuth-212 Bismuth-214 Cesium-134 Cesium-137 Cobalt-60 Europium-152 Europium-154 Lead-212 Lead-214 Potassium-40 Thallium-208 07/18/22 MXR1 UI U
U U
U U
0.179 0.585 0.599 0.0840 0.0621 0.0479 0.0584 0.125 0.173 0.0755 0.0894 0.368 0.0421 RL 0.173 0.363 0.109 0.869 0.799 DF Mr. Gerry Wood
Contact:
Zion Solutions Company :
100 Shiloh Blvd.
Zion, Illinois 60099 July 20, 2022 Report Date:
Address :
Zion Solutions Project:
586069001 Soil 05-JUL-22 14-JUL-22 L1-12102A-FSGS-201-SS ENRG08001 Project:
ENRG080 Client ID:
Client 0.665 0.000 1.31 0.803 0.0604
-0.00946 0.0204 0.0256 0.0357 0.828 1.05 20.6 0.240
+/-0.198
+/-0.348
+/-0.452
+/-0.126
+/-0.0388
+/-0.0263
+/-0.0289
+/-0.0747
+/-0.102
+/-0.0862
+/-0.126
+/-1.26
+/-0.0512 Sample ID:
Receive Date:
Client Sample ID:
Matrix:
Collect Date:
Collector:
Moisture:
Batch 8.87%
The following Prep Methods were performed Dry Soil Prep Dry Soil Prep GL-RAD-A-021 07/14/22 2289905 1900 SF1 Method Description Analyst Date Time Prep Batch Mtd.
The following Analytical Methods were performed Method Description
+/-0.209
+/-1.37
+/-0.468
+/-0.144
+/-0.0478
+/-0.0266
+/-0.0303
+/-0.0756
+/-0.103
+/-0.109
+/-0.153
+/-2.28
+/-0.0554 1
DOE HASL 300, 4.5.2.3/Ga-01-R 1
Acceptable Limits Test Recovery%
Batch ID Surrogate/Tracer Recovery MDC TPU Uncertainty PF Page 3 of 60 SDG: 586069
Certificate of Analysis GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Parameter Result Units Qualifier Analyst Date Time RL DF Mr. Gerry Wood
Contact:
Zion Solutions Company :
100 Shiloh Blvd.
Zion, Illinois 60099 July 20, 2022 Report Date:
Address :
Zion Solutions Project:
586069001 L1-12102A-FSGS-201-SS ENRG08001 Project:
ENRG080 Client ID:
Sample ID:
Client Sample ID:
Batch Mtd.
Notes:
The MDC is a sample specific MDC.
Acceptable Limits Test Recovery%
Batch ID Surrogate/Tracer Recovery MDC TPU Uncertainty TPU is calculated at the 95% confidence level (1.96-sigma).
PF Column headers are defined as follows:
DF: Dilution Factor DL: Detection Limit Lc/LC: Critical Level MDA: Minimum Detectable Activity MDC: Minimum Detectable Concentration Mtd.: Method PF: Prep Factor RL: Reporting Limit TPU: Total Propagated Uncertainty Page 4 of 60 SDG: 586069
Certificate of Analysis GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Rad Gamma Spec Analysis Parameter Result Units Qualifier Analyst Date Time Gammaspec, Gamma, Solid (Requested List) "Dry Weight Corrected" 2290065 1019 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g Actinium-228 Bismuth-211 Bismuth-212 Bismuth-214 Cesium-134 Cesium-137 Cobalt-60 Europium-152 Europium-154 Lead-212 Lead-214 Potassium-40 Thallium-208 07/18/22 MXR1 UI U
UI U
U U
U 0.304 0.182 0.580 0.0670 0.0525 0.0364 0.0410 0.0935 0.131 0.0547 0.179 0.321 0.0355 RL 0.173 0.363 0.109 0.869 0.799 DF Mr. Gerry Wood
Contact:
Zion Solutions Company :
100 Shiloh Blvd.
Zion, Illinois 60099 July 20, 2022 Report Date:
Address :
Zion Solutions Project:
586069002 Soil 05-JUL-22 14-JUL-22 L1-12102A-FSGS-202-SS ENRG08001 Project:
ENRG080 Client ID:
Client 0.606 0.000 0.280 0.625 0.000
-0.0148
-0.0107 0.00443
-0.00543 0.568 0.689 15.9 0.182
+/-0.169
+/-0.590
+/-0.281
+/-0.0902
+/-0.0554
+/-0.0212
+/-0.0227
+/-0.0476
+/-0.0688
+/-0.0738
+/-0.134
+/-1.14
+/-0.0527 Sample ID:
Receive Date:
Client Sample ID:
Matrix:
Collect Date:
Collector:
Moisture:
Batch 6.83%
The following Prep Methods were performed Dry Soil Prep Dry Soil Prep GL-RAD-A-021 07/14/22 2289905 1900 SF1 Method Description Analyst Date Time Prep Batch Mtd.
The following Analytical Methods were performed Method Description
+/-0.327
+/-0.613
+/-0.310
+/-0.105
+/-0.0628
+/-0.0223
+/-0.0232
+/-0.0477
+/-0.0688
+/-0.0881
+/-0.145
+/-1.91
+/-0.0549 1
DOE HASL 300, 4.5.2.3/Ga-01-R 1
Acceptable Limits Test Recovery%
Batch ID Surrogate/Tracer Recovery MDC TPU Uncertainty PF Page 5 of 60 SDG: 586069
Certificate of Analysis GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Parameter Result Units Qualifier Analyst Date Time RL DF Mr. Gerry Wood
Contact:
Zion Solutions Company :
100 Shiloh Blvd.
Zion, Illinois 60099 July 20, 2022 Report Date:
Address :
Zion Solutions Project:
586069002 L1-12102A-FSGS-202-SS ENRG08001 Project:
ENRG080 Client ID:
Sample ID:
Client Sample ID:
Batch Mtd.
Notes:
The MDC is a sample specific MDC.
Acceptable Limits Test Recovery%
Batch ID Surrogate/Tracer Recovery MDC TPU Uncertainty TPU is calculated at the 95% confidence level (1.96-sigma).
PF Column headers are defined as follows:
DF: Dilution Factor DL: Detection Limit Lc/LC: Critical Level MDA: Minimum Detectable Activity MDC: Minimum Detectable Concentration Mtd.: Method PF: Prep Factor RL: Reporting Limit TPU: Total Propagated Uncertainty Page 6 of 60 SDG: 586069
Certificate of Analysis GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Rad Gamma Spec Analysis Parameter Result Units Qualifier Analyst Date Time Gammaspec, Gamma, Solid (Requested List) "Dry Weight Corrected" 2290065 1020 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g Actinium-228 Bismuth-211 Bismuth-212 Bismuth-214 Cesium-134 Cesium-137 Cobalt-60 Europium-152 Europium-154 Lead-212 Lead-214 Potassium-40 Thallium-208 07/18/22 MXR1 U
UI U
U U
U U
0.166 0.319 0.391 0.0827 0.0436 0.0392 0.0468 0.0893 0.155 0.0616 0.0719 0.428 0.0377 RL 0.173 0.363 0.109 0.869 0.799 DF Mr. Gerry Wood
Contact:
Zion Solutions Company :
100 Shiloh Blvd.
Zion, Illinois 60099 July 20, 2022 Report Date:
Address :
Zion Solutions Project:
586069003 Soil 05-JUL-22 14-JUL-22 L1-12102A-FSGS-203-SS ENRG08001 Project:
ENRG080 Client ID:
Client 0.165 0.000 1.33 0.170
-0.00275
-0.0245 0.0111
-0.0591 0.0351 0.188 0.197 10.3 0.0763
+/-0.153
+/-0.297
+/-0.493
+/-0.0948
+/-0.0224
+/-0.0257
+/-0.0189
+/-0.0562
+/-0.0747
+/-0.0900
+/-0.108
+/-1.17
+/-0.0471 Sample ID:
Receive Date:
Client Sample ID:
Matrix:
Collect Date:
Collector:
Moisture:
Batch 1.81%
The following Prep Methods were performed Dry Soil Prep Dry Soil Prep GL-RAD-A-021 07/14/22 2289905 1900 SF1 Method Description Analyst Date Time Prep Batch Mtd.
The following Analytical Methods were performed Method Description
+/-0.154
+/-0.387
+/-0.506
+/-0.0959
+/-0.0224
+/-0.0280
+/-0.0195
+/-0.0624
+/-0.0764
+/-0.0914
+/-0.109
+/-1.49
+/-0.0475 1
DOE HASL 300, 4.5.2.3/Ga-01-R 1
Acceptable Limits Test Recovery%
Batch ID Surrogate/Tracer Recovery MDC TPU Uncertainty PF Page 7 of 60 SDG: 586069
Certificate of Analysis GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Parameter Result Units Qualifier Analyst Date Time RL DF Mr. Gerry Wood
Contact:
Zion Solutions Company :
100 Shiloh Blvd.
Zion, Illinois 60099 July 20, 2022 Report Date:
Address :
Zion Solutions Project:
586069003 L1-12102A-FSGS-203-SS ENRG08001 Project:
ENRG080 Client ID:
Sample ID:
Client Sample ID:
Batch Mtd.
Notes:
The MDC is a sample specific MDC.
Acceptable Limits Test Recovery%
Batch ID Surrogate/Tracer Recovery MDC TPU Uncertainty TPU is calculated at the 95% confidence level (1.96-sigma).
PF Column headers are defined as follows:
DF: Dilution Factor DL: Detection Limit Lc/LC: Critical Level MDA: Minimum Detectable Activity MDC: Minimum Detectable Concentration Mtd.: Method PF: Prep Factor RL: Reporting Limit TPU: Total Propagated Uncertainty Page 8 of 60 SDG: 586069
Certificate of Analysis GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Rad Gamma Spec Analysis Parameter Result Units Qualifier Analyst Date Time Gammaspec, Gamma, Solid (Requested List) "Dry Weight Corrected" 2290065 1020 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g Actinium-228 Bismuth-211 Bismuth-212 Bismuth-214 Cesium-134 Cesium-137 Cobalt-60 Europium-152 Europium-154 Lead-212 Lead-214 Potassium-40 Thallium-208 07/18/22 MXR1 U
UI U
U U
U U
U 0.237 0.318 0.710 0.0735 0.0569 0.0493 0.0507 0.0963 0.156 0.0399 0.0713 0.451 0.0362 RL 0.173 0.363 0.109 0.869 0.799 DF Mr. Gerry Wood
Contact:
Zion Solutions Company :
100 Shiloh Blvd.
Zion, Illinois 60099 July 20, 2022 Report Date:
Address :
Zion Solutions Project:
586069004 Soil 05-JUL-22 14-JUL-22 L1-12102A-FSGS-204-SS ENRG08001 Project:
ENRG080 Client ID:
Client 0.121 0.000 0.368 0.205 0.0375 0.00367 0.0176
-0.0211 0.0255 0.296 0.207 11.2 0.0807
+/-0.142
+/-0.238
+/-0.329
+/-0.0952
+/-0.0448
+/-0.0254
+/-0.0214
+/-0.0502
+/-0.0751
+/-0.0615
+/-0.0864
+/-1.20
+/-0.0448 Sample ID:
Receive Date:
Client Sample ID:
Matrix:
Collect Date:
Collector:
Moisture:
Batch 1.8%
The following Prep Methods were performed Dry Soil Prep Dry Soil Prep GL-RAD-A-021 07/14/22 2289905 1900 SF1 Method Description Analyst Date Time Prep Batch Mtd.
The following Analytical Methods were performed Method Description
+/-0.152
+/-0.354
+/-0.370
+/-0.0973
+/-0.0480
+/-0.0255
+/-0.0229
+/-0.0511
+/-0.0760
+/-0.0664
+/-0.0880
+/-1.53
+/-0.0455 1
DOE HASL 300, 4.5.2.3/Ga-01-R 1
Acceptable Limits Test Recovery%
Batch ID Surrogate/Tracer Recovery MDC TPU Uncertainty PF Page 9 of 60 SDG: 586069
Certificate of Analysis GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Parameter Result Units Qualifier Analyst Date Time RL DF Mr. Gerry Wood
Contact:
Zion Solutions Company :
100 Shiloh Blvd.
Zion, Illinois 60099 July 20, 2022 Report Date:
Address :
Zion Solutions Project:
586069004 L1-12102A-FSGS-204-SS ENRG08001 Project:
ENRG080 Client ID:
Sample ID:
Client Sample ID:
Batch Mtd.
Notes:
The MDC is a sample specific MDC.
Acceptable Limits Test Recovery%
Batch ID Surrogate/Tracer Recovery MDC TPU Uncertainty TPU is calculated at the 95% confidence level (1.96-sigma).
PF Column headers are defined as follows:
DF: Dilution Factor DL: Detection Limit Lc/LC: Critical Level MDA: Minimum Detectable Activity MDC: Minimum Detectable Concentration Mtd.: Method PF: Prep Factor RL: Reporting Limit TPU: Total Propagated Uncertainty Page 10 of 60 SDG: 586069
Certificate of Analysis GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Rad Gamma Spec Analysis Parameter Result Units Qualifier Analyst Date Time Gammaspec, Gamma, Solid (Requested List) "Dry Weight Corrected" 2290065 1021 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g Actinium-228 Bismuth-211 Bismuth-212 Bismuth-214 Cesium-134 Cesium-137 Cobalt-60 Europium-152 Europium-154 Lead-212 Lead-214 Potassium-40 Thallium-208 07/18/22 MXR1 U
U U
U U
U 0.185 0.218 0.717 0.106 0.0734 0.0562 0.0570 0.102 0.152 0.0637 0.228 0.477 0.0438 RL 0.173 0.363 0.109 0.869 0.799 DF Mr. Gerry Wood
Contact:
Zion Solutions Company :
100 Shiloh Blvd.
Zion, Illinois 60099 July 20, 2022 Report Date:
Address :
Zion Solutions Project:
586069005 Soil 05-JUL-22 14-JUL-22 L1-12102A-FSGS-205-SS ENRG08001 Project:
ENRG080 Client ID:
Client 0.860 0.148 0.815 0.847 0.0371 0.00348 0.0185
-0.0281
-0.0223 0.820 0.957 18.3 0.245
+/-0.233
+/-0.732
+/-0.483
+/-0.146
+/-0.0370
+/-0.0303
+/-0.0262
+/-0.0549
+/-0.0822
+/-0.0886
+/-0.129
+/-1.50
+/-0.0759 Sample ID:
Receive Date:
Client Sample ID:
Matrix:
Collect Date:
Collector:
Moisture:
Batch 6.8%
The following Prep Methods were performed Dry Soil Prep Dry Soil Prep GL-RAD-A-021 07/14/22 2289905 1900 SF1 Method Description Analyst Date Time Prep Batch Mtd.
The following Analytical Methods were performed Method Description
+/-0.244
+/-0.788
+/-0.489
+/-0.168
+/-0.0407
+/-0.0303
+/-0.0275
+/-0.0564
+/-0.0828
+/-0.112
+/-0.153
+/-2.17
+/-0.0796 1
DOE HASL 300, 4.5.2.3/Ga-01-R 1
Acceptable Limits Test Recovery%
Batch ID Surrogate/Tracer Recovery MDC TPU Uncertainty PF Page 11 of 60 SDG: 586069
Certificate of Analysis GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Parameter Result Units Qualifier Analyst Date Time RL DF Mr. Gerry Wood
Contact:
Zion Solutions Company :
100 Shiloh Blvd.
Zion, Illinois 60099 July 20, 2022 Report Date:
Address :
Zion Solutions Project:
586069005 L1-12102A-FSGS-205-SS ENRG08001 Project:
ENRG080 Client ID:
Sample ID:
Client Sample ID:
Batch Mtd.
Notes:
The MDC is a sample specific MDC.
Acceptable Limits Test Recovery%
Batch ID Surrogate/Tracer Recovery MDC TPU Uncertainty TPU is calculated at the 95% confidence level (1.96-sigma).
PF Column headers are defined as follows:
DF: Dilution Factor DL: Detection Limit Lc/LC: Critical Level MDA: Minimum Detectable Activity MDC: Minimum Detectable Concentration Mtd.: Method PF: Prep Factor RL: Reporting Limit TPU: Total Propagated Uncertainty Page 12 of 60 SDG: 586069
Certificate of Analysis GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Rad Gamma Spec Analysis Parameter Result Units Qualifier Analyst Date Time Gammaspec, Gamma, Solid (Requested List) "Dry Weight Corrected" 2290065 1043 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g Actinium-228 Bismuth-211 Bismuth-212 Bismuth-214 Cesium-134 Cesium-137 Cobalt-60 Europium-152 Europium-154 Lead-212 Lead-214 Potassium-40 Thallium-208 07/18/22 MXR1 UI U
U U
U U
0.180 0.599 0.628 0.0897 0.0559 0.0433 0.0591 0.111 0.168 0.0657 0.0836 0.312 0.0402 RL 0.173 0.363 0.109 0.869 0.799 DF Mr. Gerry Wood
Contact:
Zion Solutions Company :
100 Shiloh Blvd.
Zion, Illinois 60099 July 20, 2022 Report Date:
Address :
Zion Solutions Project:
586069006 Soil 05-JUL-22 14-JUL-22 L1-12102A-FQGS-205-SS ENRG08001 Project:
ENRG080 Client ID:
Client 0.823 0.000 0.814 0.744 0.00586
-0.00685 0.0232 0.0166 0.0358 0.732 0.868 19.5 0.229
+/-0.228
+/-0.337
+/-0.686
+/-0.137
+/-0.0283
+/-0.0243
+/-0.0443
+/-0.0565
+/-0.0935
+/-0.0820
+/-0.122
+/-1.37
+/-0.0732 Sample ID:
Receive Date:
Client Sample ID:
Matrix:
Collect Date:
Collector:
Moisture:
Batch 6.09%
The following Prep Methods were performed Dry Soil Prep Dry Soil Prep GL-RAD-A-021 07/14/22 2289905 1900 SF1 Method Description Analyst Date Time Prep Batch Mtd.
The following Analytical Methods were performed Method Description
+/-0.243
+/-1.15
+/-0.690
+/-0.152
+/-0.0284
+/-0.0245
+/-0.0456
+/-0.0570
+/-0.0950
+/-0.102
+/-0.142
+/-2.34
+/-0.0760 1
DOE HASL 300, 4.5.2.3/Ga-01-R 1
Acceptable Limits Test Recovery%
Batch ID Surrogate/Tracer Recovery MDC TPU Uncertainty PF Page 13 of 60 SDG: 586069
Certificate of Analysis GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Parameter Result Units Qualifier Analyst Date Time RL DF Mr. Gerry Wood
Contact:
Zion Solutions Company :
100 Shiloh Blvd.
Zion, Illinois 60099 July 20, 2022 Report Date:
Address :
Zion Solutions Project:
586069006 L1-12102A-FQGS-205-SS ENRG08001 Project:
ENRG080 Client ID:
Sample ID:
Client Sample ID:
Batch Mtd.
Notes:
The MDC is a sample specific MDC.
Acceptable Limits Test Recovery%
Batch ID Surrogate/Tracer Recovery MDC TPU Uncertainty TPU is calculated at the 95% confidence level (1.96-sigma).
PF Column headers are defined as follows:
DF: Dilution Factor DL: Detection Limit Lc/LC: Critical Level MDA: Minimum Detectable Activity MDC: Minimum Detectable Concentration Mtd.: Method PF: Prep Factor RL: Reporting Limit TPU: Total Propagated Uncertainty Page 14 of 60 SDG: 586069
Certificate of Analysis GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Rad Gamma Spec Analysis Parameter Result Units Qualifier Analyst Date Time Gammaspec, Gamma, Solid (Requested List) "Dry Weight Corrected" 2290065 1044 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g Actinium-228 Bismuth-211 Bismuth-212 Bismuth-214 Cesium-134 Cesium-137 Cobalt-60 Europium-152 Europium-154 Lead-212 Lead-214 Potassium-40 Thallium-208 07/18/22 MXR1 UI U
U U
U U
U 0.123 0.359 0.505 0.0558 0.0348 0.0358 0.0381 0.0813 0.116 0.0479 0.0658 0.325 0.0307 RL 0.173 0.363 0.109 0.869 0.799 DF Mr. Gerry Wood
Contact:
Zion Solutions Company :
100 Shiloh Blvd.
Zion, Illinois 60099 July 20, 2022 Report Date:
Address :
Zion Solutions Project:
586069007 Soil 05-JUL-22 14-JUL-22 L1-12102A-FSGS-206-SS ENRG08001 Project:
ENRG080 Client ID:
Client 0.352 0.000 0.148 0.254 0.000109 0.0197 0.0111
-0.0150 0.00165 0.292 0.325 13.7 0.0861
+/-0.141
+/-0.232
+/-0.256
+/-0.0748
+/-0.0175
+/-0.0179
+/-0.0176
+/-0.0426
+/-0.0604
+/-0.0580
+/-0.0843
+/-1.04
+/-0.0485 Sample ID:
Receive Date:
Client Sample ID:
Matrix:
Collect Date:
Collector:
Moisture:
Batch 5.29%
The following Prep Methods were performed Dry Soil Prep Dry Soil Prep GL-RAD-A-021 07/14/22 2289905 1900 SF1 Method Description Analyst Date Time Prep Batch Mtd.
The following Analytical Methods were performed Method Description
+/-0.145
+/-0.472
+/-0.265
+/-0.0781
+/-0.0175
+/-0.0201
+/-0.0183
+/-0.0432
+/-0.0604
+/-0.0628
+/-0.0885
+/-1.65
+/-0.0491 1
DOE HASL 300, 4.5.2.3/Ga-01-R 1
Acceptable Limits Test Recovery%
Batch ID Surrogate/Tracer Recovery MDC TPU Uncertainty PF Page 15 of 60 SDG: 586069
Certificate of Analysis GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Parameter Result Units Qualifier Analyst Date Time RL DF Mr. Gerry Wood
Contact:
Zion Solutions Company :
100 Shiloh Blvd.
Zion, Illinois 60099 July 20, 2022 Report Date:
Address :
Zion Solutions Project:
586069007 L1-12102A-FSGS-206-SS ENRG08001 Project:
ENRG080 Client ID:
Sample ID:
Client Sample ID:
Batch Mtd.
Notes:
The MDC is a sample specific MDC.
Acceptable Limits Test Recovery%
Batch ID Surrogate/Tracer Recovery MDC TPU Uncertainty TPU is calculated at the 95% confidence level (1.96-sigma).
PF Column headers are defined as follows:
DF: Dilution Factor DL: Detection Limit Lc/LC: Critical Level MDA: Minimum Detectable Activity MDC: Minimum Detectable Concentration Mtd.: Method PF: Prep Factor RL: Reporting Limit TPU: Total Propagated Uncertainty Page 16 of 60 SDG: 586069
Certificate of Analysis GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Rad Gamma Spec Analysis Parameter Result Units Qualifier Analyst Date Time Gammaspec, Gamma, Solid (Requested List) "Dry Weight Corrected" 2290065 1045 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g Actinium-228 Bismuth-211 Bismuth-212 Bismuth-214 Cesium-134 Cesium-137 Cobalt-60 Europium-152 Europium-154 Lead-212 Lead-214 Potassium-40 Thallium-208 07/18/22 MXR1 U
U U
U U
U U
0.177 0.224 0.853 0.0739 0.0616 0.0455 0.0376 0.121 0.175 0.0711 0.230 0.437 0.0435 RL 0.173 0.363 0.109 0.869 0.799 DF Mr. Gerry Wood
Contact:
Zion Solutions Company :
100 Shiloh Blvd.
Zion, Illinois 60099 July 20, 2022 Report Date:
Address :
Zion Solutions Project:
586069008 Soil 05-JUL-22 14-JUL-22 L1-12102A-FSGS-207-SS ENRG08001 Project:
ENRG080 Client ID:
Client 0.770 0.0647 0.619 0.927 0.0221 0.00506
-0.0183 0.0141 0.0288 0.796 1.02 21.2 0.238
+/-0.229
+/-0.661
+/-0.419
+/-0.124
+/-0.0314
+/-0.0237
+/-0.0221
+/-0.0615
+/-0.0876
+/-0.0942
+/-0.147
+/-1.42
+/-0.0636 Sample ID:
Receive Date:
Client Sample ID:
Matrix:
Collect Date:
Collector:
Moisture:
Batch 6.98%
The following Prep Methods were performed Dry Soil Prep Dry Soil Prep GL-RAD-A-021 07/14/22 2289905 1900 SF1 Method Description Analyst Date Time Prep Batch Mtd.
The following Analytical Methods were performed Method Description
+/-0.240
+/-0.741
+/-0.506
+/-0.147
+/-0.0330
+/-0.0238
+/-0.0237
+/-0.0619
+/-0.0886
+/-0.118
+/-0.171
+/-2.52
+/-0.0667 1
DOE HASL 300, 4.5.2.3/Ga-01-R 1
Acceptable Limits Test Recovery%
Batch ID Surrogate/Tracer Recovery MDC TPU Uncertainty PF Page 17 of 60 SDG: 586069
Certificate of Analysis GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Parameter Result Units Qualifier Analyst Date Time RL DF Mr. Gerry Wood
Contact:
Zion Solutions Company :
100 Shiloh Blvd.
Zion, Illinois 60099 July 20, 2022 Report Date:
Address :
Zion Solutions Project:
586069008 L1-12102A-FSGS-207-SS ENRG08001 Project:
ENRG080 Client ID:
Sample ID:
Client Sample ID:
Batch Mtd.
Notes:
The MDC is a sample specific MDC.
Acceptable Limits Test Recovery%
Batch ID Surrogate/Tracer Recovery MDC TPU Uncertainty TPU is calculated at the 95% confidence level (1.96-sigma).
PF Column headers are defined as follows:
DF: Dilution Factor DL: Detection Limit Lc/LC: Critical Level MDA: Minimum Detectable Activity MDC: Minimum Detectable Concentration Mtd.: Method PF: Prep Factor RL: Reporting Limit TPU: Total Propagated Uncertainty Page 18 of 60 SDG: 586069
Certificate of Analysis GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Rad Gamma Spec Analysis Parameter Result Units Qualifier Analyst Date Time Gammaspec, Gamma, Solid (Requested List) "Dry Weight Corrected" 2290065 1046 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g Actinium-228 Bismuth-211 Bismuth-212 Bismuth-214 Cesium-134 Cesium-137 Cobalt-60 Europium-152 Europium-154 Lead-212 Lead-214 Potassium-40 Thallium-208 07/18/22 MXR1 UI U
U U
U U
0.131 0.305 0.535 0.0608 0.0402 0.0302 0.0382 0.0803 0.146 0.0538 0.0570 0.391 0.0288 RL 0.173 0.363 0.109 0.869 0.799 DF Mr. Gerry Wood
Contact:
Zion Solutions Company :
100 Shiloh Blvd.
Zion, Illinois 60099 July 20, 2022 Report Date:
Address :
Zion Solutions Project:
586069009 Soil 05-JUL-22 14-JUL-22 L1-12102A-FSGS-208-SS ENRG08001 Project:
ENRG080 Client ID:
Client 0.376 0.000 0.150 0.256
-0.00375 0.113 0.00204
-0.000344 0.0287 0.269 0.308 10.6 0.105
+/-0.180
+/-0.238
+/-0.263
+/-0.0755
+/-0.0229
+/-0.0379
+/-0.0217
+/-0.0434
+/-0.0730
+/-0.0682
+/-0.0865
+/-0.924
+/-0.0379 Sample ID:
Receive Date:
Client Sample ID:
Matrix:
Collect Date:
Collector:
Moisture:
Batch 1.69%
The following Prep Methods were performed Dry Soil Prep Dry Soil Prep GL-RAD-A-021 07/14/22 2289905 1900 SF1 Method Description Analyst Date Time Prep Batch Mtd.
The following Analytical Methods were performed Method Description
+/-0.184
+/-0.457
+/-0.272
+/-0.0785
+/-0.0230
+/-0.0390
+/-0.0217
+/-0.0434
+/-0.0742
+/-0.0720
+/-0.0902
+/-1.42
+/-0.0389 1
DOE HASL 300, 4.5.2.3/Ga-01-R 1
Acceptable Limits Test Recovery%
Batch ID Surrogate/Tracer Recovery MDC TPU Uncertainty PF Page 19 of 60 SDG: 586069
Certificate of Analysis GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Parameter Result Units Qualifier Analyst Date Time RL DF Mr. Gerry Wood
Contact:
Zion Solutions Company :
100 Shiloh Blvd.
Zion, Illinois 60099 July 20, 2022 Report Date:
Address :
Zion Solutions Project:
586069009 L1-12102A-FSGS-208-SS ENRG08001 Project:
ENRG080 Client ID:
Sample ID:
Client Sample ID:
Batch Mtd.
Notes:
The MDC is a sample specific MDC.
Acceptable Limits Test Recovery%
Batch ID Surrogate/Tracer Recovery MDC TPU Uncertainty TPU is calculated at the 95% confidence level (1.96-sigma).
PF Column headers are defined as follows:
DF: Dilution Factor DL: Detection Limit Lc/LC: Critical Level MDA: Minimum Detectable Activity MDC: Minimum Detectable Concentration Mtd.: Method PF: Prep Factor RL: Reporting Limit TPU: Total Propagated Uncertainty Page 20 of 60 SDG: 586069
Certificate of Analysis GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Rad Gamma Spec Analysis Parameter Result Units Qualifier Analyst Date Time Gammaspec, Gamma, Solid (Requested List) "Dry Weight Corrected" 2290065 1046 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g Actinium-228 Bismuth-211 Bismuth-212 Bismuth-214 Cesium-134 Cesium-137 Cobalt-60 Europium-152 Europium-154 Lead-212 Lead-214 Potassium-40 Thallium-208 07/18/22 MXR1 UI U
U U
U U
U 0.126 0.273 0.425 0.0595 0.0340 0.0351 0.0309 0.0832 0.107 0.0491 0.0579 0.363 0.0273 RL 0.173 0.363 0.109 0.869 0.799 DF Mr. Gerry Wood
Contact:
Zion Solutions Company :
100 Shiloh Blvd.
Zion, Illinois 60099 July 20, 2022 Report Date:
Address :
Zion Solutions Project:
586069010 Soil 05-JUL-22 14-JUL-22 L1-12102A-FSGS-209-SS ENRG08001 Project:
ENRG080 Client ID:
Client 0.231 0.000 0.210 0.176 0.00368 0.00934 0.00158 0.00358
-0.0333 0.200 0.177 9.71 0.0593
+/-0.134
+/-0.277
+/-0.187
+/-0.0738
+/-0.0172
+/-0.0172
+/-0.0146
+/-0.0411
+/-0.0596
+/-0.0686
+/-0.101
+/-0.906
+/-0.0367 Sample ID:
Receive Date:
Client Sample ID:
Matrix:
Collect Date:
Collector:
Moisture:
Batch 1.6%
The following Prep Methods were performed Dry Soil Prep Dry Soil Prep GL-RAD-A-021 07/14/22 2289905 1900 SF1 Method Description Analyst Date Time Prep Batch Mtd.
The following Analytical Methods were performed Method Description
+/-0.136
+/-0.356
+/-0.210
+/-0.0752
+/-0.0173
+/-0.0177
+/-0.0146
+/-0.0412
+/-0.0615
+/-0.0708
+/-0.102
+/-1.31
+/-0.0371 1
DOE HASL 300, 4.5.2.3/Ga-01-R 1
Acceptable Limits Test Recovery%
Batch ID Surrogate/Tracer Recovery MDC TPU Uncertainty PF Page 21 of 60 SDG: 586069
Certificate of Analysis GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Parameter Result Units Qualifier Analyst Date Time RL DF Mr. Gerry Wood
Contact:
Zion Solutions Company :
100 Shiloh Blvd.
Zion, Illinois 60099 July 20, 2022 Report Date:
Address :
Zion Solutions Project:
586069010 L1-12102A-FSGS-209-SS ENRG08001 Project:
ENRG080 Client ID:
Sample ID:
Client Sample ID:
Batch Mtd.
Notes:
The MDC is a sample specific MDC.
Acceptable Limits Test Recovery%
Batch ID Surrogate/Tracer Recovery MDC TPU Uncertainty TPU is calculated at the 95% confidence level (1.96-sigma).
PF Column headers are defined as follows:
DF: Dilution Factor DL: Detection Limit Lc/LC: Critical Level MDA: Minimum Detectable Activity MDC: Minimum Detectable Concentration Mtd.: Method PF: Prep Factor RL: Reporting Limit TPU: Total Propagated Uncertainty Page 22 of 60 SDG: 586069
Certificate of Analysis GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Rad Gamma Spec Analysis Parameter Result Units Qualifier Analyst Date Time Gammaspec, Gamma, Solid (Requested List) "Dry Weight Corrected" 2290065 1050 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g Actinium-228 Bismuth-211 Bismuth-212 Bismuth-214 Cesium-134 Cesium-137 Cobalt-60 Europium-152 Europium-154 Lead-212 Lead-214 Potassium-40 Thallium-208 07/18/22 MXR1 U
U U
U U
U U
UI 0.108 0.137 0.490 0.0647 0.0347 0.0276 0.0416 0.0770 0.142 0.0459 0.108 0.313 0.0302 RL 0.173 0.363 0.109 0.869 0.799 DF Mr. Gerry Wood
Contact:
Zion Solutions Company :
100 Shiloh Blvd.
Zion, Illinois 60099 July 20, 2022 Report Date:
Address :
Zion Solutions Project:
586069011 Soil 05-JUL-22 14-JUL-22 L1-12102A-FSGS-210-SS ENRG08001 Project:
ENRG080 Client ID:
Client 0.299 0.00543 0.0362 0.205 0.00274
-0.00376 0.0237
-0.00372 0.0499 0.191 0.246 9.68 0.000
+/-0.114
+/-0.380
+/-0.266
+/-0.0757
+/-0.0167
+/-0.0149
+/-0.0164
+/-0.0385
+/-0.0687
+/-0.0747
+/-0.0924
+/-0.945
+/-0.0431 Sample ID:
Receive Date:
Client Sample ID:
Matrix:
Collect Date:
Collector:
Moisture:
Batch 3.31%
The following Prep Methods were performed Dry Soil Prep Dry Soil Prep GL-RAD-A-021 07/14/22 2289905 1900 SF1 Method Description Analyst Date Time Prep Batch Mtd.
The following Analytical Methods were performed Method Description
+/-0.117
+/-0.387
+/-0.267
+/-0.0777
+/-0.0167
+/-0.0150
+/-0.0197
+/-0.0385
+/-0.0724
+/-0.0765
+/-0.0947
+/-1.33
+/-0.0432 1
DOE HASL 300, 4.5.2.3/Ga-01-R 1
Acceptable Limits Test Recovery%
Batch ID Surrogate/Tracer Recovery MDC TPU Uncertainty PF Page 23 of 60 SDG: 586069
Certificate of Analysis GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Parameter Result Units Qualifier Analyst Date Time RL DF Mr. Gerry Wood
Contact:
Zion Solutions Company :
100 Shiloh Blvd.
Zion, Illinois 60099 July 20, 2022 Report Date:
Address :
Zion Solutions Project:
586069011 L1-12102A-FSGS-210-SS ENRG08001 Project:
ENRG080 Client ID:
Sample ID:
Client Sample ID:
Batch Mtd.
Notes:
The MDC is a sample specific MDC.
Acceptable Limits Test Recovery%
Batch ID Surrogate/Tracer Recovery MDC TPU Uncertainty TPU is calculated at the 95% confidence level (1.96-sigma).
PF Column headers are defined as follows:
DF: Dilution Factor DL: Detection Limit Lc/LC: Critical Level MDA: Minimum Detectable Activity MDC: Minimum Detectable Concentration Mtd.: Method PF: Prep Factor RL: Reporting Limit TPU: Total Propagated Uncertainty Page 24 of 60 SDG: 586069
Certificate of Analysis GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Rad Gamma Spec Analysis Parameter Result Units Qualifier Analyst Date Time Gammaspec, Gamma, Solid (Requested List) "Dry Weight Corrected" 2290065 1319 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g Actinium-228 Bismuth-211 Bismuth-212 Bismuth-214 Cesium-134 Cesium-137 Cobalt-60 Europium-152 Europium-154 Lead-212 Lead-214 Potassium-40 Thallium-208 07/18/22 MXR1 UI U
U U
U U
0.265 0.379 0.453 0.0729 0.0515 0.0369 0.0285 0.0943 0.121 0.0569 0.0715 0.389 0.0335 RL 0.173 0.363 0.109 0.869 0.799 DF Mr. Gerry Wood
Contact:
Zion Solutions Company :
100 Shiloh Blvd.
Zion, Illinois 60099 July 20, 2022 Report Date:
Address :
Zion Solutions Project:
586069012 Soil 05-JUL-22 14-JUL-22 L1-12102A-FSGS-210-SB ENRG08001 Project:
ENRG080 Client ID:
Client 0.422 0.000 0.891 0.196 0.0170
-0.00596
-0.0120
-0.0410
-0.0285 0.317 0.337 11.3 0.0712
+/-0.176
+/-0.280
+/-0.523
+/-0.127
+/-0.0251
+/-0.0199
+/-0.0164
+/-0.0573
+/-0.0753
+/-0.0680
+/-0.102
+/-1.08
+/-0.0460 Sample ID:
Receive Date:
Client Sample ID:
Matrix:
Collect Date:
Collector:
Moisture:
Batch 2.93%
The following Prep Methods were performed Dry Soil Prep Dry Soil Prep GL-RAD-A-021 07/14/22 2289905 1900 SF1 Method Description Analyst Date Time Prep Batch Mtd.
The following Analytical Methods were performed Method Description
+/-0.263
+/-0.510
+/-0.529
+/-0.128
+/-0.0263
+/-0.0201
+/-0.0173
+/-0.0604
+/-0.0765
+/-0.0744
+/-0.106
+/-1.57
+/-0.0464 1
DOE HASL 300, 4.5.2.3/Ga-01-R 1
Acceptable Limits Test Recovery%
Batch ID Surrogate/Tracer Recovery MDC TPU Uncertainty PF Page 25 of 60 SDG: 586069
Certificate of Analysis GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Parameter Result Units Qualifier Analyst Date Time RL DF Mr. Gerry Wood
Contact:
Zion Solutions Company :
100 Shiloh Blvd.
Zion, Illinois 60099 July 20, 2022 Report Date:
Address :
Zion Solutions Project:
586069012 L1-12102A-FSGS-210-SB ENRG08001 Project:
ENRG080 Client ID:
Sample ID:
Client Sample ID:
Batch Mtd.
Notes:
The MDC is a sample specific MDC.
Acceptable Limits Test Recovery%
Batch ID Surrogate/Tracer Recovery MDC TPU Uncertainty TPU is calculated at the 95% confidence level (1.96-sigma).
PF Column headers are defined as follows:
DF: Dilution Factor DL: Detection Limit Lc/LC: Critical Level MDA: Minimum Detectable Activity MDC: Minimum Detectable Concentration Mtd.: Method PF: Prep Factor RL: Reporting Limit TPU: Total Propagated Uncertainty Page 26 of 60 SDG: 586069
Certificate of Analysis GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Rad Gamma Spec Analysis Parameter Result Units Qualifier Analyst Date Time Gammaspec, Gamma, Solid (Requested List) "Dry Weight Corrected" 2290065 1319 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g Actinium-228 Bismuth-211 Bismuth-212 Bismuth-214 Cesium-134 Cesium-137 Cobalt-60 Europium-152 Europium-154 Lead-212 Lead-214 Potassium-40 Thallium-208 07/18/22 MXR1 U
U U
U U
U 0.217 0.171 0.510 0.0690 0.0439 0.0338 0.0425 0.0772 0.111 0.0864 0.108 0.315 0.0349 RL 0.173 0.363 0.109 0.869 0.799 DF Mr. Gerry Wood
Contact:
Zion Solutions Company :
100 Shiloh Blvd.
Zion, Illinois 60099 July 20, 2022 Report Date:
Address :
Zion Solutions Project:
586069013 Soil 05-JUL-22 14-JUL-22 L1-12102A-FSGS-211-SS ENRG08001 Project:
ENRG080 Client ID:
Client 0.276 0.504 0.147 0.150 0.00563
-0.00207 0.0218 0.00180
-0.0512 0.302 0.183 9.98 0.0837
+/-0.149
+/-0.184
+/-0.268
+/-0.0641
+/-0.0215
+/-0.0180
+/-0.0312
+/-0.0427
+/-0.0656
+/-0.0783
+/-0.0667
+/-0.894
+/-0.0309 Sample ID:
Receive Date:
Client Sample ID:
Matrix:
Collect Date:
Collector:
Moisture:
Batch 2.79%
The following Prep Methods were performed Dry Soil Prep Dry Soil Prep GL-RAD-A-021 07/14/22 2289905 1900 SF1 Method Description Analyst Date Time Prep Batch Mtd.
The following Analytical Methods were performed Method Description
+/-0.196
+/-0.189
+/-0.276
+/-0.0655
+/-0.0216
+/-0.0181
+/-0.0328
+/-0.0427
+/-0.0696
+/-0.159
+/-0.107
+/-1.32
+/-0.0318 1
DOE HASL 300, 4.5.2.3/Ga-01-R 1
Acceptable Limits Test Recovery%
Batch ID Surrogate/Tracer Recovery MDC TPU Uncertainty PF Page 27 of 60 SDG: 586069
Certificate of Analysis GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Parameter Result Units Qualifier Analyst Date Time RL DF Mr. Gerry Wood
Contact:
Zion Solutions Company :
100 Shiloh Blvd.
Zion, Illinois 60099 July 20, 2022 Report Date:
Address :
Zion Solutions Project:
586069013 L1-12102A-FSGS-211-SS ENRG08001 Project:
ENRG080 Client ID:
Sample ID:
Client Sample ID:
Batch Mtd.
Notes:
The MDC is a sample specific MDC.
Acceptable Limits Test Recovery%
Batch ID Surrogate/Tracer Recovery MDC TPU Uncertainty TPU is calculated at the 95% confidence level (1.96-sigma).
PF Column headers are defined as follows:
DF: Dilution Factor DL: Detection Limit Lc/LC: Critical Level MDA: Minimum Detectable Activity MDC: Minimum Detectable Concentration Mtd.: Method PF: Prep Factor RL: Reporting Limit TPU: Total Propagated Uncertainty Page 28 of 60 SDG: 586069
Certificate of Analysis GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Rad Gamma Spec Analysis Parameter Result Units Qualifier Analyst Date Time Gammaspec, Gamma, Solid (Requested List) "Dry Weight Corrected" 2290065 1320 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g Actinium-228 Bismuth-211 Bismuth-212 Bismuth-214 Cesium-134 Cesium-137 Cobalt-60 Europium-152 Europium-154 Lead-212 Lead-214 Potassium-40 Thallium-208 07/18/22 MXR1 UI U
U U
U U
0.190 0.670 0.697 0.0971 0.0644 0.0531 0.0544 0.138 0.203 0.0779 0.110 0.494 0.0483 RL 0.173 0.363 0.109 0.869 0.799 DF Mr. Gerry Wood
Contact:
Zion Solutions Company :
100 Shiloh Blvd.
Zion, Illinois 60099 July 20, 2022 Report Date:
Address :
Zion Solutions Project:
586069014 Soil 05-JUL-22 14-JUL-22 L1-12102A-FSGS-211-SB ENRG08001 Project:
ENRG080 Client ID:
Client 1.04 0.000 0.922 0.856 0.0634 0.0113
-0.00493
-0.00384 0.0586 0.878 1.00 20.7 0.266
+/-0.281
+/-0.443
+/-0.758
+/-0.135
+/-0.0711
+/-0.0267
+/-0.0283
+/-0.0755
+/-0.0992
+/-0.102
+/-0.161
+/-1.56
+/-0.0582 Sample ID:
Receive Date:
Client Sample ID:
Matrix:
Collect Date:
Collector:
Moisture:
Batch 10.8%
The following Prep Methods were performed Dry Soil Prep Dry Soil Prep GL-RAD-A-021 07/14/22 2289905 1900 SF1 Method Description Analyst Date Time Prep Batch Mtd.
The following Analytical Methods were performed Method Description
+/-0.297
+/-1.34
+/-0.763
+/-0.153
+/-0.0769
+/-0.0272
+/-0.0284
+/-0.0755
+/-0.103
+/-0.130
+/-0.181
+/-2.49
+/-0.0624 1
DOE HASL 300, 4.5.2.3/Ga-01-R 1
Acceptable Limits Test Recovery%
Batch ID Surrogate/Tracer Recovery MDC TPU Uncertainty PF Page 29 of 60 SDG: 586069
Certificate of Analysis GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Parameter Result Units Qualifier Analyst Date Time RL DF Mr. Gerry Wood
Contact:
Zion Solutions Company :
100 Shiloh Blvd.
Zion, Illinois 60099 July 20, 2022 Report Date:
Address :
Zion Solutions Project:
586069014 L1-12102A-FSGS-211-SB ENRG08001 Project:
ENRG080 Client ID:
Sample ID:
Client Sample ID:
Batch Mtd.
Notes:
The MDC is a sample specific MDC.
Acceptable Limits Test Recovery%
Batch ID Surrogate/Tracer Recovery MDC TPU Uncertainty TPU is calculated at the 95% confidence level (1.96-sigma).
PF Column headers are defined as follows:
DF: Dilution Factor DL: Detection Limit Lc/LC: Critical Level MDA: Minimum Detectable Activity MDC: Minimum Detectable Concentration Mtd.: Method PF: Prep Factor RL: Reporting Limit TPU: Total Propagated Uncertainty Page 30 of 60 SDG: 586069
Certificate of Analysis GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Rad Gamma Spec Analysis Parameter Result Units Qualifier Analyst Date Time Gammaspec, Gamma, Solid (Requested List) "Dry Weight Corrected" 2290065 1320 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g Actinium-228 Bismuth-211 Bismuth-212 Bismuth-214 Cesium-134 Cesium-137 Cobalt-60 Europium-152 Europium-154 Lead-212 Lead-214 Potassium-40 Thallium-208 07/18/22 MXR1 UI U
U U
U U
U 0.119 0.159 0.456 0.0579 0.0306 0.0457 0.0378 0.0839 0.104 0.0470 0.0946 0.271 0.0279 RL 0.173 0.363 0.109 0.869 0.799 DF Mr. Gerry Wood
Contact:
Zion Solutions Company :
100 Shiloh Blvd.
Zion, Illinois 60099 July 20, 2022 Report Date:
Address :
Zion Solutions Project:
586069015 Soil 05-JUL-22 14-JUL-22 L1-12102A-FSGS-212-SS ENRG08001 Project:
ENRG080 Client ID:
Client 0.202 0.000 0.123 0.190 0.00244
-0.0110 0.00706 0.000471 0.0124 0.156 0.200 10.8 0.0673
+/-0.129
+/-0.422
+/-0.245
+/-0.0850
+/-0.0149
+/-0.0235
+/-0.0185
+/-0.0431
+/-0.0538
+/-0.0627
+/-0.0717
+/-0.876
+/-0.0344 Sample ID:
Receive Date:
Client Sample ID:
Matrix:
Collect Date:
Collector:
Moisture:
Batch 1.29%
The following Prep Methods were performed Dry Soil Prep Dry Soil Prep GL-RAD-A-021 07/14/22 2289905 1900 SF1 Method Description Analyst Date Time Prep Batch Mtd.
The following Analytical Methods were performed Method Description
+/-0.130
+/-0.425
+/-0.252
+/-0.0867
+/-0.0149
+/-0.0241
+/-0.0188
+/-0.0431
+/-0.0541
+/-0.0640
+/-0.0738
+/-1.31
+/-0.0350 1
DOE HASL 300, 4.5.2.3/Ga-01-R 1
Acceptable Limits Test Recovery%
Batch ID Surrogate/Tracer Recovery MDC TPU Uncertainty PF Page 31 of 60 SDG: 586069
Certificate of Analysis GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Parameter Result Units Qualifier Analyst Date Time RL DF Mr. Gerry Wood
Contact:
Zion Solutions Company :
100 Shiloh Blvd.
Zion, Illinois 60099 July 20, 2022 Report Date:
Address :
Zion Solutions Project:
586069015 L1-12102A-FSGS-212-SS ENRG08001 Project:
ENRG080 Client ID:
Sample ID:
Client Sample ID:
Batch Mtd.
Notes:
The MDC is a sample specific MDC.
Acceptable Limits Test Recovery%
Batch ID Surrogate/Tracer Recovery MDC TPU Uncertainty TPU is calculated at the 95% confidence level (1.96-sigma).
PF Column headers are defined as follows:
DF: Dilution Factor DL: Detection Limit Lc/LC: Critical Level MDA: Minimum Detectable Activity MDC: Minimum Detectable Concentration Mtd.: Method PF: Prep Factor RL: Reporting Limit TPU: Total Propagated Uncertainty Page 32 of 60 SDG: 586069
Certificate of Analysis GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Rad Gamma Spec Analysis Parameter Result Units Qualifier Analyst Date Time Gammaspec, Gamma, Solid (Requested List) "Dry Weight Corrected" 2290065 1320 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g Actinium-228 Bismuth-211 Bismuth-212 Bismuth-214 Cesium-134 Cesium-137 Cobalt-60 Europium-152 Europium-154 Lead-212 Lead-214 Potassium-40 Thallium-208 07/18/22 MXR1 UI U
U U
U U
0.192 0.241 0.572 0.0771 0.0559 0.0517 0.0478 0.115 0.170 0.0674 0.237 0.298 0.0461 RL 0.173 0.363 0.109 0.869 0.799 DF Mr. Gerry Wood
Contact:
Zion Solutions Company :
100 Shiloh Blvd.
Zion, Illinois 60099 July 20, 2022 Report Date:
Address :
Zion Solutions Project:
586069016 Soil 05-JUL-22 14-JUL-22 L1-12102A-FSGS-213-SS ENRG08001 Project:
ENRG080 Client ID:
Client 0.748 0.000 0.979 0.903 0.0153
-0.00412
-0.0134 0.00825
-0.0128 0.795 1.20 21.6 0.204
+/-0.271
+/-0.721
+/-0.605
+/-0.158
+/-0.0284
+/-0.0291
+/-0.0270
+/-0.0642
+/-0.0924
+/-0.0910
+/-0.137
+/-1.38
+/-0.0570 Sample ID:
Receive Date:
Client Sample ID:
Matrix:
Collect Date:
Collector:
Moisture:
Batch 7.08%
The following Prep Methods were performed Dry Soil Prep Dry Soil Prep GL-RAD-A-021 07/14/22 2289905 1900 SF1 Method Description Analyst Date Time Prep Batch Mtd.
The following Analytical Methods were performed Method Description
+/-0.280
+/-0.797
+/-0.612
+/-0.179
+/-0.0293
+/-0.0292
+/-0.0277
+/-0.0643
+/-0.0926
+/-0.111
+/-0.168
+/-2.29
+/-0.0601 1
DOE HASL 300, 4.5.2.3/Ga-01-R 1
Acceptable Limits Test Recovery%
Batch ID Surrogate/Tracer Recovery MDC TPU Uncertainty PF Page 33 of 60 SDG: 586069
Certificate of Analysis GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Parameter Result Units Qualifier Analyst Date Time RL DF Mr. Gerry Wood
Contact:
Zion Solutions Company :
100 Shiloh Blvd.
Zion, Illinois 60099 July 20, 2022 Report Date:
Address :
Zion Solutions Project:
586069016 L1-12102A-FSGS-213-SS ENRG08001 Project:
ENRG080 Client ID:
Sample ID:
Client Sample ID:
Batch Mtd.
Notes:
The MDC is a sample specific MDC.
Acceptable Limits Test Recovery%
Batch ID Surrogate/Tracer Recovery MDC TPU Uncertainty TPU is calculated at the 95% confidence level (1.96-sigma).
PF Column headers are defined as follows:
DF: Dilution Factor DL: Detection Limit Lc/LC: Critical Level MDA: Minimum Detectable Activity MDC: Minimum Detectable Concentration Mtd.: Method PF: Prep Factor RL: Reporting Limit TPU: Total Propagated Uncertainty Page 34 of 60 SDG: 586069
Certificate of Analysis GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Rad Gamma Spec Analysis Parameter Result Units Qualifier Analyst Date Time Gammaspec, Gamma, Solid (Requested List) "Dry Weight Corrected" 2290065 1321 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g Actinium-228 Bismuth-211 Bismuth-212 Bismuth-214 Cesium-134 Cesium-137 Cobalt-60 Europium-152 Europium-154 Lead-212 Lead-214 Potassium-40 Thallium-208 07/18/22 MXR1 UI U
UI U
U U
U 0.111 0.162 0.499 0.0525 0.0336 0.0328 0.0363 0.0716 0.0903 0.0421 0.114 0.237 0.0305 RL 0.173 0.363 0.109 0.869 0.799 DF Mr. Gerry Wood
Contact:
Zion Solutions Company :
100 Shiloh Blvd.
Zion, Illinois 60099 July 20, 2022 Report Date:
Address :
Zion Solutions Project:
586069017 Soil 05-JUL-22 14-JUL-22 L1-12102A-FSGS-214-SS ENRG08001 Project:
ENRG080 Client ID:
Client 0.268 0.000 0.207 0.261 0.000 0.00101 0.00541
-0.0157
-0.0195 0.244 0.250 9.21 0.0442
+/-0.138
+/-0.353
+/-0.264
+/-0.0873
+/-0.0236
+/-0.0188
+/-0.0180
+/-0.0375
+/-0.0503
+/-0.0536
+/-0.0744
+/-0.783
+/-0.0329 Sample ID:
Receive Date:
Client Sample ID:
Matrix:
Collect Date:
Collector:
Moisture:
Batch 1.32%
The following Prep Methods were performed Dry Soil Prep Dry Soil Prep GL-RAD-A-021 07/14/22 2289905 1900 SF1 Method Description Analyst Date Time Prep Batch Mtd.
The following Analytical Methods were performed Method Description
+/-0.140
+/-0.358
+/-0.280
+/-0.0903
+/-0.0284
+/-0.0188
+/-0.0182
+/-0.0382
+/-0.0511
+/-0.0573
+/-0.0771
+/-1.15
+/-0.0331 1
DOE HASL 300, 4.5.2.3/Ga-01-R 1
Acceptable Limits Test Recovery%
Batch ID Surrogate/Tracer Recovery MDC TPU Uncertainty PF Page 35 of 60 SDG: 586069
Certificate of Analysis GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Parameter Result Units Qualifier Analyst Date Time RL DF Mr. Gerry Wood
Contact:
Zion Solutions Company :
100 Shiloh Blvd.
Zion, Illinois 60099 July 20, 2022 Report Date:
Address :
Zion Solutions Project:
586069017 L1-12102A-FSGS-214-SS ENRG08001 Project:
ENRG080 Client ID:
Sample ID:
Client Sample ID:
Batch Mtd.
Notes:
The MDC is a sample specific MDC.
Acceptable Limits Test Recovery%
Batch ID Surrogate/Tracer Recovery MDC TPU Uncertainty TPU is calculated at the 95% confidence level (1.96-sigma).
PF Column headers are defined as follows:
DF: Dilution Factor DL: Detection Limit Lc/LC: Critical Level MDA: Minimum Detectable Activity MDC: Minimum Detectable Concentration Mtd.: Method PF: Prep Factor RL: Reporting Limit TPU: Total Propagated Uncertainty Page 36 of 60 SDG: 586069
Certificate of Analysis GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Rad Gamma Spec Analysis Parameter Result Units Qualifier Analyst Date Time Gammaspec, Gamma, Solid (Requested List) "Dry Weight Corrected" 2290065 1321 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g Actinium-228 Bismuth-211 Bismuth-212 Bismuth-214 Cesium-134 Cesium-137 Cobalt-60 Europium-152 Europium-154 Lead-212 Lead-214 Potassium-40 Thallium-208 07/18/22 MXR1 UI U
U U
U U
U 0.101 0.220 0.324 0.0474 0.0291 0.0268 0.0316 0.0668 0.0881 0.0376 0.0468 0.232 0.0245 RL 0.173 0.363 0.109 0.869 0.799 DF Mr. Gerry Wood
Contact:
Zion Solutions Company :
100 Shiloh Blvd.
Zion, Illinois 60099 July 20, 2022 Report Date:
Address :
Zion Solutions Project:
586069018 Soil 05-JUL-22 14-JUL-22 L1-12102A-FSGS-215-SS ENRG08001 Project:
ENRG080 Client ID:
Client 0.198 0.000 0.275 0.115 0.0147 0.000809 0.00526 0.00135
-0.00659 0.252 0.251 11.0 0.0629
+/-0.131
+/-0.170
+/-0.283
+/-0.0544
+/-0.0218
+/-0.0150
+/-0.0158
+/-0.0356
+/-0.0485
+/-0.0534
+/-0.0617
+/-0.764
+/-0.0344 Sample ID:
Receive Date:
Client Sample ID:
Matrix:
Collect Date:
Collector:
Moisture:
Batch 1.78%
The following Prep Methods were performed Dry Soil Prep Dry Soil Prep GL-RAD-A-021 07/14/22 2289905 1900 SF1 Method Description Analyst Date Time Prep Batch Mtd.
The following Analytical Methods were performed Method Description
+/-0.132
+/-0.360
+/-0.284
+/-0.0554
+/-0.0229
+/-0.0150
+/-0.0160
+/-0.0356
+/-0.0486
+/-0.0571
+/-0.0650
+/-1.24
+/-0.0349 1
DOE HASL 300, 4.5.2.3/Ga-01-R 1
Acceptable Limits Test Recovery%
Batch ID Surrogate/Tracer Recovery MDC TPU Uncertainty PF Page 37 of 60 SDG: 586069
Certificate of Analysis GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Parameter Result Units Qualifier Analyst Date Time RL DF Mr. Gerry Wood
Contact:
Zion Solutions Company :
100 Shiloh Blvd.
Zion, Illinois 60099 July 20, 2022 Report Date:
Address :
Zion Solutions Project:
586069018 L1-12102A-FSGS-215-SS ENRG08001 Project:
ENRG080 Client ID:
Sample ID:
Client Sample ID:
Batch Mtd.
Notes:
The MDC is a sample specific MDC.
Acceptable Limits Test Recovery%
Batch ID Surrogate/Tracer Recovery MDC TPU Uncertainty TPU is calculated at the 95% confidence level (1.96-sigma).
PF Column headers are defined as follows:
DF: Dilution Factor DL: Detection Limit Lc/LC: Critical Level MDA: Minimum Detectable Activity MDC: Minimum Detectable Concentration Mtd.: Method PF: Prep Factor RL: Reporting Limit TPU: Total Propagated Uncertainty Page 38 of 60 SDG: 586069
Certificate of Analysis GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Rad Gamma Spec Analysis Parameter Result Units Qualifier Analyst Date Time Gammaspec, Gamma, Solid (Requested List) "Dry Weight Corrected" 2290065 1321 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g Actinium-228 Bismuth-211 Bismuth-212 Bismuth-214 Cesium-134 Cesium-137 Cobalt-60 Europium-152 Europium-154 Lead-212 Lead-214 Potassium-40 Thallium-208 07/18/22 MXR1 UI U
U U
U U
U 0.191 0.262 0.552 0.0553 0.0373 0.0400 0.0296 0.0863 0.0925 0.0450 0.0581 0.305 0.0297 RL 0.173 0.363 0.109 0.869 0.799 DF Mr. Gerry Wood
Contact:
Zion Solutions Company :
100 Shiloh Blvd.
Zion, Illinois 60099 July 20, 2022 Report Date:
Address :
Zion Solutions Project:
586069019 Soil 05-JUL-22 14-JUL-22 L1-12102A-FSGS-216-SS ENRG08001 Project:
ENRG080 Client ID:
Client 0.221 0.000 0.274 0.193 0.0105 0.0188
-0.00385 0.0306
-0.0257 0.233 0.171 10.3 0.0440
+/-0.130
+/-0.253
+/-0.266
+/-0.0647
+/-0.0202
+/-0.0199
+/-0.0152
+/-0.0410
+/-0.0502
+/-0.0634
+/-0.0918
+/-0.849
+/-0.0397 Sample ID:
Receive Date:
Client Sample ID:
Matrix:
Collect Date:
Collector:
Moisture:
Batch 1.06%
The following Prep Methods were performed Dry Soil Prep Dry Soil Prep GL-RAD-A-021 07/14/22 2289905 1900 SF1 Method Description Analyst Date Time Prep Batch Mtd.
The following Analytical Methods were performed Method Description
+/-0.165
+/-0.333
+/-0.295
+/-0.0669
+/-0.0207
+/-0.0217
+/-0.0153
+/-0.0433
+/-0.0515
+/-0.0664
+/-0.0929
+/-1.28
+/-0.0399 1
DOE HASL 300, 4.5.2.3/Ga-01-R 1
Acceptable Limits Test Recovery%
Batch ID Surrogate/Tracer Recovery MDC TPU Uncertainty PF Page 39 of 60 SDG: 586069
Certificate of Analysis GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Parameter Result Units Qualifier Analyst Date Time RL DF Mr. Gerry Wood
Contact:
Zion Solutions Company :
100 Shiloh Blvd.
Zion, Illinois 60099 July 20, 2022 Report Date:
Address :
Zion Solutions Project:
586069019 L1-12102A-FSGS-216-SS ENRG08001 Project:
ENRG080 Client ID:
Sample ID:
Client Sample ID:
Batch Mtd.
Notes:
The MDC is a sample specific MDC.
Acceptable Limits Test Recovery%
Batch ID Surrogate/Tracer Recovery MDC TPU Uncertainty TPU is calculated at the 95% confidence level (1.96-sigma).
PF Column headers are defined as follows:
DF: Dilution Factor DL: Detection Limit Lc/LC: Critical Level MDA: Minimum Detectable Activity MDC: Minimum Detectable Concentration Mtd.: Method PF: Prep Factor RL: Reporting Limit TPU: Total Propagated Uncertainty Page 40 of 60 SDG: 586069
Certificate of Analysis GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Rad Gamma Spec Analysis Parameter Result Units Qualifier Analyst Date Time Gammaspec, Gamma, Solid (Requested List) "Dry Weight Corrected" 2290065 1322 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g Actinium-228 Bismuth-211 Bismuth-212 Bismuth-214 Cesium-134 Cesium-137 Cobalt-60 Europium-152 Europium-154 Lead-212 Lead-214 Potassium-40 Thallium-208 07/18/22 MXR1 UI U
U U
U U
U 0.116 0.146 0.440 0.0579 0.0361 0.0339 0.0286 0.0783 0.124 0.0467 0.113 0.299 0.0303 RL 0.173 0.363 0.109 0.869 0.799 DF Mr. Gerry Wood
Contact:
Zion Solutions Company :
100 Shiloh Blvd.
Zion, Illinois 60099 July 20, 2022 Report Date:
Address :
Zion Solutions Project:
586069020 Soil 05-JUL-22 14-JUL-22 L1-12102A-FSGS-217-SS ENRG08001 Project:
ENRG080 Client ID:
Client 0.283 0.000 0.136 0.195
-0.000366
-0.00254
-0.00296 0.00350 0.0250 0.236 0.272 12.3 0.0540
+/-0.133
+/-0.423
+/-0.207
+/-0.0862
+/-0.0184
+/-0.0189
+/-0.0149
+/-0.0406
+/-0.0621
+/-0.0525
+/-0.0855
+/-0.936
+/-0.0361 Sample ID:
Receive Date:
Client Sample ID:
Matrix:
Collect Date:
Collector:
Moisture:
Batch 2.66%
The following Prep Methods were performed Dry Soil Prep Dry Soil Prep GL-RAD-A-021 07/14/22 2289905 1900 SF1 Method Description Analyst Date Time Prep Batch Mtd.
The following Analytical Methods were performed Method Description
+/-0.135
+/-0.428
+/-0.216
+/-0.0882
+/-0.0184
+/-0.0189
+/-0.0150
+/-0.0406
+/-0.0631
+/-0.0559
+/-0.0885
+/-1.44
+/-0.0365 1
DOE HASL 300, 4.5.2.3/Ga-01-R 1
Acceptable Limits Test Recovery%
Batch ID Surrogate/Tracer Recovery MDC TPU Uncertainty PF Page 41 of 60 SDG: 586069
Certificate of Analysis GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Parameter Result Units Qualifier Analyst Date Time RL DF Mr. Gerry Wood
Contact:
Zion Solutions Company :
100 Shiloh Blvd.
Zion, Illinois 60099 July 20, 2022 Report Date:
Address :
Zion Solutions Project:
586069020 L1-12102A-FSGS-217-SS ENRG08001 Project:
ENRG080 Client ID:
Sample ID:
Client Sample ID:
Batch Mtd.
Notes:
The MDC is a sample specific MDC.
Acceptable Limits Test Recovery%
Batch ID Surrogate/Tracer Recovery MDC TPU Uncertainty TPU is calculated at the 95% confidence level (1.96-sigma).
PF Column headers are defined as follows:
DF: Dilution Factor DL: Detection Limit Lc/LC: Critical Level MDA: Minimum Detectable Activity MDC: Minimum Detectable Concentration Mtd.: Method PF: Prep Factor RL: Reporting Limit TPU: Total Propagated Uncertainty Page 42 of 60 SDG: 586069
Certificate of Analysis GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Rad Gamma Spec Analysis Parameter Result Units Qualifier Analyst Date Time Gammaspec, Gamma, Solid (Requested List) "Dry Weight Corrected" 2290067 1325 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g Actinium-228 Bismuth-211 Bismuth-212 Bismuth-214 Cesium-134 Cesium-137 Cobalt-60 Europium-152 Europium-154 Lead-212 Lead-214 Potassium-40 Thallium-208 07/18/22 MXR1 UI U
U U
U U
0.117 0.401 0.450 0.0621 0.0412 0.0308 0.0370 0.0809 0.115 0.0449 0.0579 0.260 0.0271 RL 0.173 0.363 0.109 0.869 0.799 DF Mr. Gerry Wood
Contact:
Zion Solutions Company :
100 Shiloh Blvd.
Zion, Illinois 60099 July 20, 2022 Report Date:
Address :
Zion Solutions Project:
586069021 Soil 05-JUL-22 14-JUL-22 L1-12102A-FSGS-218-SS ENRG08001 Project:
ENRG080 Client ID:
Client 0.577 0.000 0.718 0.536 0.00215
-0.00670 0.00428 0.0179 0.00429 0.663 0.735 17.9 0.181
+/-0.161
+/-0.285
+/-0.370
+/-0.105
+/-0.0220
+/-0.0170
+/-0.0181
+/-0.0396
+/-0.0662
+/-0.0712
+/-0.104
+/-1.12
+/-0.0425 Sample ID:
Receive Date:
Client Sample ID:
Matrix:
Collect Date:
Collector:
Moisture:
Batch 6.51%
The following Prep Methods were performed Dry Soil Prep Dry Soil Prep GL-RAD-A-021 07/14/22 2289907 1903 SF1 Method Description Analyst Date Time Prep Batch Mtd.
The following Analytical Methods were performed Method Description
+/-0.170
+/-0.972
+/-0.376
+/-0.115
+/-0.0221
+/-0.0172
+/-0.0182
+/-0.0405
+/-0.0663
+/-0.0901
+/-0.121
+/-2.02
+/-0.0453 1
DOE HASL 300, 4.5.2.3/Ga-01-R 1
Acceptable Limits Test Recovery%
Batch ID Surrogate/Tracer Recovery MDC TPU Uncertainty PF Page 43 of 60 SDG: 586069
Certificate of Analysis GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Parameter Result Units Qualifier Analyst Date Time RL DF Mr. Gerry Wood
Contact:
Zion Solutions Company :
100 Shiloh Blvd.
Zion, Illinois 60099 July 20, 2022 Report Date:
Address :
Zion Solutions Project:
586069021 L1-12102A-FSGS-218-SS ENRG08001 Project:
ENRG080 Client ID:
Sample ID:
Client Sample ID:
Batch Mtd.
Notes:
The MDC is a sample specific MDC.
Acceptable Limits Test Recovery%
Batch ID Surrogate/Tracer Recovery MDC TPU Uncertainty TPU is calculated at the 95% confidence level (1.96-sigma).
PF Column headers are defined as follows:
DF: Dilution Factor DL: Detection Limit Lc/LC: Critical Level MDA: Minimum Detectable Activity MDC: Minimum Detectable Concentration Mtd.: Method PF: Prep Factor RL: Reporting Limit TPU: Total Propagated Uncertainty Page 44 of 60 SDG: 586069
QC Summary GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Rad Gamma Spec 2290065 Batch Actinium-228 Bismuth-211 Bismuth-212 Bismuth-214 Cesium-134 Cesium-137 Cobalt-60 Europium-152 Europium-154 Lead-212 Lead-214 Potassium-40 Thallium-208 Americium-241 Parmname Mr. Gerry Wood
Contact:
Zion Solutions Client :
100 Shiloh Blvd.
Zion, Illinois July 20, 2022 Report Date:
Units pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g Anlst Date Time MXR1 MXR1 07/18/22 07/18/22 13:23 13:24 QC 0.676 0.000 1.29 0.705 0.0287 0.0321 0.00222
-0.0314 0.0216 0.817 1.08 21.1 0.286 566 NOM Sample 0.665 0.000 1.31 0.803 0.0604
-0.00946 0.0204 0.0256 0.0357 0.828 1.05 20.6 0.240 Range (0% - 100%)
N/A (0% - 100%)
(0%-20%)
N/A N/A N/A N/A N/A (0%-20%)
(0%-20%)
(0%-20%)
(0%-20%)
(75%-125%)
Qual UI U
U U
U U
QC1205139810 586069001 QC1205139811 REC%
117 485 DUP LCS 586069 Workorder:
UI U
U U
U U
+/-0.198
+/-0.348
+/-0.452
+/-0.126
+/-0.0388
+/-0.0263
+/-0.0289
+/-0.0747
+/-0.102
+/-0.0862
+/-0.126
+/-1.26
+/-0.0512
+/-0.217
+/-0.769
+/-0.533
+/-0.126
+/-0.0382
+/-0.0266
+/-0.0216
+/-0.0565
+/-0.0781
+/-0.0845
+/-0.139
+/-1.29
+/-0.0537 Uncert:
Uncert:
Uncert:
Uncert:
Uncert:
Uncert:
Uncert:
Uncert:
Uncert:
Uncert:
Uncert:
Uncert:
Uncert:
TPU:
TPU:
TPU:
TPU:
TPU:
TPU:
TPU:
TPU:
TPU:
TPU:
TPU:
TPU:
TPU:
+/-0.209
+/-1.37
+/-0.468
+/-0.144
+/-0.0478
+/-0.0266
+/-0.0303
+/-0.0756
+/-0.103
+/-0.109
+/-0.153
+/-2.28
+/-0.0554
+/-0.227
+/-0.827
+/-0.547
+/-0.141
+/-0.0404
+/-0.0268
+/-0.0216
+/-0.0583
+/-0.0787
+/-0.108
+/-0.165
+/-2.36
+/-0.0595 1.57 0
1.85 13 0
0 0
0 0
1.4 2.72 2.35 17.7 RPD%
Page 1 of 7 Page 45 of 60 SDG: 586069
QC Summary GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Rad Gamma Spec 2290065 Batch Actinium-228 Bismuth-211 Bismuth-212 Bismuth-214 Cesium-134 Cesium-137 Cobalt-60 Europium-152 Europium-154 Lead-212 Lead-214 Potassium-40 Thallium-208 Actinium-228 Bismuth-211 Parmname Units pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g Anlst Date Time MXR1 07/18/2213:22 QC 0.0156
-0.272
-1.54 0.362
-0.115 156 73.9 0.232 0.346 0.219 0.642
-0.0996
-0.0838 0.0103
-0.0177 NOM Sample Range (75%-125%)
(75%-125%)
Qual U
U U
U U
U U
U U
U U
U U
QC1205139809 REC%
99.1 98.5 157 75.0 MB 586069 Workorder:
+/-13.6
+/-2.41
+/-2.78
+/-5.99
+/-0.866
+/-0.589
+/-3.23
+/-2.73
+/-1.37
+/-0.656
+/-0.668
+/-1.01
+/-1.32
+/-0.441
+/-0.0578 Uncert:
Uncert:
Uncert:
Uncert:
Uncert:
Uncert:
Uncert:
Uncert:
Uncert:
Uncert:
Uncert:
Uncert:
Uncert:
Uncert:
Uncert:
TPU:
TPU:
TPU:
TPU:
TPU:
TPU:
TPU:
TPU:
TPU:
TPU:
TPU:
TPU:
TPU:
TPU:
TPU:
+/-65.7
+/-2.41
+/-2.78
+/-6.03
+/-0.882
+/-0.591
+/-13.7
+/-7.77
+/-1.37
+/-0.675
+/-0.675
+/-1.05
+/-1.32
+/-0.443
+/-0.0580 RPD%
Page 2 of 7 Page 46 of 60 SDG: 586069
QC Summary GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Rad Gamma Spec 2290065 2290067 Batch Batch Bismuth-212 Bismuth-214 Cesium-134 Cesium-137 Cobalt-60 Europium-152 Europium-154 Lead-212 Lead-214 Potassium-40 Thallium-208 Actinium-228 Bismuth-211 Bismuth-212 Parmname Units pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g Anlst Date Time MXR1 07/19/2209:40 QC
-0.0305 0.0432
-0.00213 0.0181 0.00313
-0.0208 0.00983 0.0114
-0.0152
-0.179
-0.0111 0.604 0.000 0.888 NOM Sample 0.577 0.000 0.718 Range (0% - 100%)
N/A (0% - 100%)
Qual U
U U
U U
U U
U U
U U
UI QC1205139816 586069021 REC%
DUP 586069 Workorder:
UI
+/-0.161
+/-0.285
+/-0.370
+/-0.0732
+/-0.175
+/-0.0395
+/-0.0146
+/-0.0141
+/-0.0132
+/-0.0262
+/-0.0275
+/-0.0283
+/-0.0263
+/-0.163
+/-0.0132
+/-0.260
+/-0.432
+/-0.598 Uncert:
Uncert:
Uncert:
Uncert:
Uncert:
Uncert:
Uncert:
Uncert:
Uncert:
Uncert:
Uncert:
Uncert:
Uncert:
Uncert:
Uncert:
TPU:
TPU:
TPU:
TPU:
TPU:
TPU:
TPU:
TPU:
TPU:
TPU:
TPU:
TPU:
TPU:
TPU:
TPU:
+/-0.170
+/-0.972
+/-0.376
+/-0.0736
+/-0.175
+/-0.0441
+/-0.0147
+/-0.0163
+/-0.0133
+/-0.0279
+/-0.0279
+/-0.0288
+/-0.0272
+/-0.183
+/-0.0142
+/-0.267
+/-1.04
+/-0.603 4.71 0
21.2 RPD%
Page 3 of 7 Page 47 of 60 SDG: 586069
QC Summary GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Rad Gamma Spec 2290067 Batch Bismuth-214 Cesium-134 Cesium-137 Cobalt-60 Europium-152 Europium-154 Lead-212 Lead-214 Potassium-40 Thallium-208 Americium-241 Actinium-228 Bismuth-211 Bismuth-212 Bismuth-214 Parmname Units pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g Anlst Date Time MXR1 07/18/2213:43 QC 0.493 0.0388
-0.00194 0.0138
-0.0166
-0.0523 0.738 0.751 19.6 0.201 537
-0.598
-0.678 0.0358 0.378 NOM Sample 0.536 0.00215
-0.00670 0.00428 0.0179 0.00429 0.663 0.735 17.9 0.181 Range (0%-20%)
N/A N/A N/A N/A N/A (0%-20%)
(0%-20%)
(0%-20%)
(0%-20%)
(75%-125%)
Qual U
U U
U U
U U
U U
QC1205139817 REC%
111 485 LCS 586069 Workorder:
U U
U U
U
+/-0.105
+/-0.0220
+/-0.0170
+/-0.0181
+/-0.0396
+/-0.0662
+/-0.0712
+/-0.104
+/-1.12
+/-0.0425
+/-0.185
+/-0.0588
+/-0.0333
+/-0.0309
+/-0.0786
+/-0.0918
+/-0.120
+/-0.157
+/-1.74
+/-0.0685
+/-10.8
+/-2.58
+/-2.70
+/-5.47
+/-0.837 Uncert:
Uncert:
Uncert:
Uncert:
Uncert:
Uncert:
Uncert:
Uncert:
Uncert:
Uncert:
Uncert:
Uncert:
Uncert:
Uncert:
Uncert:
TPU:
TPU:
TPU:
TPU:
TPU:
TPU:
TPU:
TPU:
TPU:
TPU:
TPU:
TPU:
TPU:
TPU:
TPU:
+/-0.115
+/-0.0221
+/-0.0172
+/-0.0182
+/-0.0405
+/-0.0663
+/-0.0901
+/-0.121
+/-2.02
+/-0.0453
+/-0.189
+/-0.0614
+/-0.0333
+/-0.0315
+/-0.0789
+/-0.0949
+/-0.135
+/-0.168
+/-2.58
+/-0.0706
+/-61.9
+/-2.60
+/-2.72
+/-5.47
+/-0.855 8.36 0
0 0
0 0
10.7 2.25 9.45 10.6 RPD%
Page 4 of 7 Page 48 of 60 SDG: 586069
QC Summary GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Rad Gamma Spec 2290067 Batch Cesium-134 Cesium-137 Cobalt-60 Europium-152 Europium-154 Lead-212 Lead-214 Potassium-40 Thallium-208 Actinium-228 Bismuth-211 Bismuth-212 Bismuth-214 Cesium-134 Cesium-137 Parmname Units pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g Anlst Date Time MXR1 07/18/2213:25 QC
-0.0624 158 73.3 0.0476 0.270
-0.0987
-0.258
-0.505 0.00823
-0.000911 0.0389 0.0103
-0.0198 0.0351 0.00661 NOM Sample Range (75%-125%)
(75%-125%)
Qual U
U U
U U
U U
U U
U U
U U
QC1205139815 REC%
101 97.7 157 75.0 MB 586069 Workorder:
+/-0.514
+/-3.28
+/-2.69
+/-1.31
+/-0.739
+/-0.755
+/-1.00
+/-1.81
+/-0.423
+/-0.0713
+/-0.0874
+/-0.188
+/-0.0330
+/-0.0169
+/-0.0126 Uncert:
Uncert:
Uncert:
Uncert:
Uncert:
Uncert:
Uncert:
Uncert:
Uncert:
Uncert:
Uncert:
Uncert:
Uncert:
Uncert:
Uncert:
TPU:
TPU:
TPU:
TPU:
TPU:
TPU:
TPU:
TPU:
TPU:
TPU:
TPU:
TPU:
TPU:
TPU:
TPU:
+/-0.515
+/-13.9
+/-7.70
+/-1.31
+/-0.750
+/-0.756
+/-1.01
+/-1.82
+/-0.423
+/-0.0713
+/-0.0892
+/-0.188
+/-0.0342
+/-0.0234
+/-0.0129 RPD%
Page 5 of 7 Page 49 of 60 SDG: 586069
QC Summary GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Rad Gamma Spec 2290067 Batch Cobalt-60 Europium-152 Europium-154 Lead-212 Lead-214 Potassium-40 Thallium-208 Parmname Units pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g Anlst Date Time QC
-0.0133
-0.0158 0.0115 0.0137
-0.00823 0.0506 0.0126 NOM Sample Range Qual U
U U
U U
U U
The Qualifiers in this report are defined as follows:
REC%
586069 Workorder:
BD FA H
J J
K L
M M
N/A N1 ND NJ Q
R Analyte is a Tracer compound Result is less than value reported Result is greater than value reported Results are either below the MDC or tracer recovery is low Failed analysis.
Analytical holding time was exceeded See case narrative for an explanation Value is estimated Analyte present. Reported value may be biased high. Actual value is expected to be lower.
Analyte present. Reported value may be biased low. Actual value is expected to be higher.
M if above MDC and less than LLD REMP Result > MDC/CL and < RDL RPD or %Recovery limits do not apply.
See case narrative Analyte concentration is not detected above the detection limit Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier One or more quality control criteria have not been met. Refer to the applicable narrative or DER.
Sample results are rejected
+/-0.0150
+/-0.0355
+/-0.0422
+/-0.0464
+/-0.0334
+/-0.294
+/-0.0179 Uncert:
Uncert:
Uncert:
Uncert:
Uncert:
Uncert:
Uncert:
TPU:
TPU:
TPU:
TPU:
TPU:
TPU:
TPU:
+/-0.0162
+/-0.0362
+/-0.0425
+/-0.0468
+/-0.0336
+/-0.294
+/-0.0188 RPD%
TPU and Counting Uncertainty are calculated at the 95% confidence level (1.96-sigma).
Notes:
Page 6 of 7 Page 50 of 60 SDG: 586069
QC Summary GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Parmname Page 7 of 7 Units Anlst Date Time QC NOM Sample Range Qual REC%
586069 Workorder:
U UI UJ UL X
Y
^
h Analyte was analyzed for, but not detected above the MDL, MDA, MDC or LOD.
Gamma Spectroscopy--Uncertain identification Gamma Spectroscopy--Uncertain identification Not considered detected. The associated number is the reported concentration, which may be inaccurate due to a low bias.
Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Other specific qualifiers were required to properly define the results. Consult case narrative.
RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL. Qualifier Not Applicable for Radiochemistry.
Preparation or preservation holding time was exceeded N/A indicates that spike recovery limits do not apply when sample concentration exceeds spike conc. by a factor of 4 or more or %RPD not applicable.
- Indicates analyte is a surrogate/tracer compound.
^ The Relative Percent Difference (RPD) obtained from the sample duplicate (DUP) is evaluated against the acceptence criteria when the sample is greater than five times (5X) the contract required detection limit (RL). In cases where either the sample or duplicate value is less than 5X the RL, a control limit of +/- the RL is used to evaluate the DUP result.
For PS, PSD, and SDILT results, the values listed are the measured amounts, not final concentrations.
Where the analytical method has been performed under NELAP certification, the analysis has met all of the requirements of the NELAC standard unless qualified on the QC Summary.
RPD%
Page 51 of 60 SDG: 586069
Page 52 of 60 SDG: 586069
.*~~
ZIONSOL(;TJONSw:
M~~~
Sample ID LJ-l 2102A-FSGS-20l-SS LJ-12102A -FSGS-202-SS l.l-12l02A -FSGS-203-SS
!.1-121 02A -FSGS-204-SS LI-12102A -FSGS-205-SS LI-l2102A -F(}GS-20!\-SS LJ-I2102A -FSGS-206-SS LJ-12102A-FSGS-207-SS LaborBIOI)':
GEL Laboratorie<. LLC 2040 S.avago Road Charleston, SC 29407 Matrix SOIL SOJL SOJL SOJL SOIL SOIL SOIL SOIL i;l;~rr ~,ck~rt Relinquished by:
Attachment l - Chain-of-Custodv Form Sample Sample Container
&,mp!< Date Sample Analysis Type Type Vol Unit Type Qty Time SOIL 850.7]
grams NIA I
07/05/2022 0845 Gamma Spec SOIL 850.21 grams NIA I
07/05/2022 0848 Gamma Spec SOIL 850.71 grams NIA I
07/05/2022 0853 Gamma Spec SOIL 850.78 grams NIA I
07/05/2022 0855 Gamma Spec SOIL 850. 71 grams NIA I
07/05/2022 090]
GammaSpcc SOIL 850.71 grams NIA I
07/0512022 0903 Gamma Spec SOJL 850.70 grams NIA I
07/05/2012 0918 GammaSpec SOIL 850.72 grams NIA J
07105/2022 0921 Gamma Spec Date Submitted To Lab:
Ship Container No.:
Cooler Temperature:
ZS-WM-131 RevisionO Information Use 5flo0(o'1 PreseIYative Remarks I
NIA See comments NIA See comm¢nts NIA Sec comments NIA See commentS NIA See comments NIA See comments NIA See comments NIA See comments Airbill Number:
or; /1J./2oii.
HA tM 7773 5'1-71 78(3 Dato (tttm/dd/yyyy):
Time:
Received by:
Date: (mm/dd/yyyy):
Time:
07/!JJ;..op 1530 Fed0l /
A 07/tJ/J..OJ-l
}530 Date'(mm/dd/yyyy):
Time:
- 7t:f:'I<'(
Dme07Ji:nio L '-'
Time:
\.
~
O'(oD Comments: Gamma Spec indloes Cs137, Csl34, Co60 K-40, Bi-211/212/214, Pb-21~14: Ac-228, Tl-200 as per June 23, 2021 e-mail and follow-up phone caHs 1 _of_3_
Page 53 of 60 SDG: 586069
-~
llONSOLUTJONSLLc
,\atfflu,~~..,
Sample 1D Ll-12102A-FSGS-208-SS Ll-l2J02A -FSGS-209-SS L 1-12!02A -FSGS-210-SS l,1-12102A-FSGS-2J0-SB Ll-12102A-FSGS-211-SS l.l-l2102A -FSGS.Zl !-SB Lf-12l02A-FSGS*212~5S Ll*l2102A-FSGS-213-SS Laboratory:
GEL Laboratories, LLC 2040 S,n,age Rcrod Charleston, SC 29407 Relinquished by:
Matrix SOIL SOIL SOIL SOIL SOIL SOIL SOIL SOIL
~,1o"~ PR,'Jru-.{-
Relinquished by:
ZS-WM-131 RevisionO fnfonnation Use Anfil:hmeat 1 - Chain-of-Custod'l form 58t.o oeo, Sample Sample Container Sample Dale Sample Analysis Type Preservative Remarks Type Vol Unit Type Qty Time
- son, 850.71 grams NIA l
07/05/2022 0926 GammaSpe<:
NIA See comment-,
SOIL 8$0,66 grams NIA I
07/05/2022 0930 GammaSpec NIA See comments SOIL 850.71 grams NIA I
07/05/2022 0920 Gamma Spec NIA See comments SOIL 850.78 grams NIA I
07/0S/ZOll 0924 Gamma Spec NIA See comments SOIL 850.71 grams NIA I
07/05/2022 0926 GammaSpcc NIA See comments SOIL 8511.90 grams NIA I
07/05/2022 0935 Gamma Spec NIA See comments SOIL 850. 75 grams NIA I
07/05/2022 0937 Gamma Spec NIA See comments SOIL 850.88 grams NIA l
07/05/2022 0939 Gamma Spec NIA See comments Dille Subm;n,;d To Lab:
Ship Container No.:
Cooler Temperature:
Airl>il!Number:
07/f'J../ZOJ.2.,
ti&
NA 7773 f/?7 7tB Date (mm/ddiyyyy):
Time:
Received bv:
Date: fmmtd<V;m):
Time:
()'7 /j 11.2.b,'l.J_
J.530 E<d£x
/'"\
(}17/1 J/10 a.
- -.30 Date (mm/d&lyyyy)
Time:
- JfSP Date
- (mmldblmyJ
Time:
01/Jtf(lot:i.
QC(oo Comments: Gamma Spec includes Cs137, Cs134, CoOO K-40, Bi-211/212/214, Pb-21~~. Ac~228, Tl-208 as per June 23, 2021 e-mail and follow-up phone calls
_2_of_3_
Page 54 of 60 SDG: 586069
-~
ZlONSOWTIONSuc
>nl:Mrijf~~
Sample ID Matrix Ll-12102A-FSGS-214-SS SOil Li-12102A -FSGS-215-SS SOil Ll-12I02A-FSGS-216-SS SOIL Ll-12J02A -FSGS-217-SS SOIL l.1-12i02A -FSGS-218-SS sort Laboratory:
GEL Laboratories, LLC 2040 Savage Road Charleston, SC 29407 Relinguished by:
~i<harJ YrRickut Relinquished by:
AttachmentJ - Ctuiin-of..Cust0.9.:'lfonn Sample Sample Container Sample Om Sample Analysis Type Preservative Type Yo!
Unit Time Type Qty SOIL 850.71 grams NIA I
07/05/2022 0942 Gamma Spec NIA SOIL 850.74 grams NIA I
07/05/2022 0945 Gamma Spec NIA SOIL 850.74 grams NIA I
0710512022 0948 Gamma Spec NIA SOIL 850.86 grams NIA I
07/05/2022 0951 Gamma Spec NIA SOIL 850.72 grams NIA I
0710512022 0954 Gamma Spec NIA Dall: Submitted To Lab:
Ship Conrainer No.:
Cooler Temperature:
Airbi!I Number:
07 /f J../ 1-0J.-J-.
!U,
/:!A 1773 Date (mm/ddfm,y):
Time:
Received by:
Date: (mm'ddryyyy):
01 /rJ.h..op...
!530 f rd £<1.
I 07/!1/Jfn'l-Dail ( nu&ddlyyyy l:
Time:
Reccive7 Ll--1}--.,_Date: (mmlddfjyyy):
07/14/ U>L'2
~ *~
l ZS-WM-131 Revision 0
- Information Use Sf tooto4 Remarks See comments See comments Seo comments Sec comments See comments sm 1sr.5 Time:
/530 Time:
Cf?OD Comments: Gamma Spec indudes Csl37, Cs134, Co60 K-40, Bi-211/212/214, Pb-212/214, 4.2,J. Tl-208 as~ June 23, 2021 e-mailandfoffow-up phone calls
______Lof_3_
Page 55 of 60 SDG: 586069 SAMPLE RECEIPT & REVIEW FORM SDG/AR/COC/Work Order:
Date Received:
Courier Other Carrier and Tracking Number Suspected Hazard Information
~.;_,;,If Net Counrs > lOOcpm on sample~ not m,u'ked "radioacti\'e", cnn!act the Radiation S*-1fety Group for ftu1her lnve!>figation.
A)Shi d as a DOT Hazardous' B) Did the client designate the samples are to he received.l!i radioactive'!
r"""
C) Did the RSO classify the samples as rudioaclive'?
DJ Did the clienr desi are.sam lcs are hazardous?
E) Did the RSO identify ossihle hazards?
Sample Receipt Criteria Shipping comaincrs received intact and scaled?
2 Chain of custody documents included with shipment'?
3 Smnples requiring cold preservation within (0 < 6 deg, C)?*
4 Daily check performed and passed on IR temperature gun?
5 Sample containers intact and scaled?
6 Samples requiring chemical preservation at proper pH?
7 Do any samples require Volatile Analysis?
8 Samples received within holding time?
9 Sample !D's on COC match !D's on bottles?
Date & time on COC match date & time lO on bottles?
Number of containers received match 11 number indicated on COC?
2 Are sample containers identifiable as l
GEL rovided b use of GEL labels?
13 COC form is properly signed in relinquished/received :rections0 Comments (Use Continuation Form if needed):
1\,/ I (. O '--
Hazard Class Shipped:
UN#: -
If UN2910, ls the Radioactive Shipment Survey Compliant? Yes_ No_
COC notation or radioactive stickers on contuinern equal client desi!,'Tlation.
(Observed Cou111s - Area Background Counts): _..,,..,e;.:_,.<'-*'JI" Rad 2 Rad 3 If Dor Eis yes, select Hazards below, PCB's Flammable Foreign Soil RCRA Asbestos Beryllium Other:,
Comments/Qualifiers (Required for Non-Confomling Items)
Circle-Applicable:
Seals broken Da1m1gcd container Leaking container Other (describe)
Circk Applicable:
Client contnctcd nnd pf<Hidcd COC Preservation Mi:thoJ: Wet kl!'
kc Packs D1y ice
- all temperatures are rccor<lcll in Celsius Temperature Device Serial #:._-'lF,_*-~...,,..,,._,1=.,,,,
Secondary Temperature Device Setf5i # (If Applicable):
COC created opon receipt t!
O!hcr:
Circle Applic.1hlc:
Sc:tls hrokcn Damaged conrni.ncr Leaking container Other (describe)
Sample ID':- nnd Cont.tlncrs Affected:
ff Preservation added, Lo1#:
TEMP:
If Yes, are Encores or Soil Kits present for solids? Yes_ No_ NA_(lf yes, take 10 VO/\ Freezer)
Do liquid VOA vials contain acid preservation? Yes_ No_ NA_(lfunknown, select No)
Are liquid VOA vials free ofheadspace? Yes_ No_ NA_
Sample fD's and containers alfoc1cd:
!D'.s and tests affected:
ID'::; unJ cunr.iiners.1ffecte<l:
Circle Applicable: No dates on containers No times on containers COC missing info Other (dtsctibe)
Circle Applicable: No contoincr count on COC Other {describe)
Not relinquished Other (describe)
Page __ of __
GL-CHL-SR-001 Rev 7
State Certification Alabama Alaska Alaska Drinking Water Arkansas CLIA California Colorado Connecticut DoD ELAP/ ISO17025 A2LA Florida NELAP Foreign Soils Permit Georgia Georgia SDWA Hawaii Idaho Illinois NELAP Indiana Kansas NELAP Kentucky SDWA Kentucky Wastewater Louisiana Drinking Water Louisiana NELAP Maine Maryland Massachusetts Massachusetts PFAS Approv Michigan Mississippi Nebraska Nevada New Hampshire NELAP New Jersey NELAP New Mexico New York NELAP North Carolina North Carolina SDWA North Dakota Oklahoma Pennsylvania NELAP Puerto Rico S. Carolina Radiochem Sanitation Districts of L South Carolina Chemistry Tennessee Texas NELAP Utah NELAP Vermont Virginia NELAP Washington 42200 17018 SC00012 880651 42D0904046 2940 SC00012 PH0169 2567.01 E87156 P3301500283, P3301500253 SC00012 967 SC00012 SC00012 200029 CSC01 E10332 90129 90129 LA024 03046 (AI33904) 2019020 270 MSC012 Letter 9976 SC00012 NEOS2613 SC0001220225 2054 SC002 SC00012 11501 233 45709 R158 2019165 6800485 SC00012 10120002 9255651 10120001 TN 02934 T1047042352220 SC00012202136 VT87156 460202 C780 List of current GEL Certifications as of 20 July 2022 Page 56 of 60 SDG: 586069
Radiochemistry Technical Case Narrative Zion Solutions SDG #: 586069 Product: Dry Weight Preparation Method: Dry Soil Prep Preparation Procedure: GL-RAD-A-021 REV# 24 Preparation Batch: 2289905 The following samples were analyzed using the above methods and analytical procedure(s).
GEL Sample ID# Client Sample Identification 586069001 L1-12102A-FSGS-201-SS 586069002 L1-12102A-FSGS-202-SS 586069003 L1-12102A-FSGS-203-SS 586069004 L1-12102A-FSGS-204-SS 586069005 L1-12102A-FSGS-205-SS 586069006 L1-12102A-FQGS-205-SS 586069007 L1-12102A-FSGS-206-SS 586069008 L1-12102A-FSGS-207-SS 586069009 L1-12102A-FSGS-208-SS 586069010 L1-12102A-FSGS-209-SS 586069011 L1-12102A-FSGS-210-SS 586069012 L1-12102A-FSGS-210-SB 586069013 L1-12102A-FSGS-211-SS 586069014 L1-12102A-FSGS-211-SB 586069015 L1-12102A-FSGS-212-SS 586069016 L1-12102A-FSGS-213-SS 586069017 L1-12102A-FSGS-214-SS 586069018 L1-12102A-FSGS-215-SS 586069019 L1-12102A-FSGS-216-SS 586069020 L1-12102A-FSGS-217-SS The samples in this SDG were analyzed on an "as received" basis.
Data Summary:
There are no exceptions, anomalies or deviations from the specified methods. All sample data provided in this report met the acceptance criteria specified in the analytical methods and procedures for initial calibration, continuing calibration, instrument controls and process controls where applicable.
Product: Dry Weight Preparation Method: Dry Soil Prep Preparation Procedure: GL-RAD-A-021 REV# 24 Preparation Batch: 2289907 Page 57 of 60 SDG: 586069
The following samples were analyzed using the above methods and analytical procedure(s).
GEL Sample ID# Client Sample Identification 586069021 L1-12102A-FSGS-218-SS The samples in this SDG were analyzed on an "as received" basis.
Data Summary:
There are no exceptions, anomalies or deviations from the specified methods. All sample data provided in this report met the acceptance criteria specified in the analytical methods and procedures for initial calibration, continuing calibration, instrument controls and process controls where applicable.
Product: Gammaspec, Gamma, Solid (Requested List)
Analytical Method: DOE HASL 300, 4.5.2.3/Ga-01-R Analytical Procedure: GL-RAD-A-013 REV# 27 Analytical Batch: 2290065 Preparation Method: Dry Soil Prep Preparation Procedure: GL-RAD-A-021 REV# 24 Preparation Batch: 2289905 The following samples were analyzed using the above methods and analytical procedure(s).
GEL Sample ID# Client Sample Identification 586069001 L1-12102A-FSGS-201-SS 586069002 L1-12102A-FSGS-202-SS 586069003 L1-12102A-FSGS-203-SS 586069004 L1-12102A-FSGS-204-SS 586069005 L1-12102A-FSGS-205-SS 586069006 L1-12102A-FQGS-205-SS 586069007 L1-12102A-FSGS-206-SS 586069008 L1-12102A-FSGS-207-SS 586069009 L1-12102A-FSGS-208-SS 586069010 L1-12102A-FSGS-209-SS 586069011 L1-12102A-FSGS-210-SS 586069012 L1-12102A-FSGS-210-SB 586069013 L1-12102A-FSGS-211-SS 586069014 L1-12102A-FSGS-211-SB 586069015 L1-12102A-FSGS-212-SS 586069016 L1-12102A-FSGS-213-SS 586069017 L1-12102A-FSGS-214-SS 586069018 L1-12102A-FSGS-215-SS 586069019 L1-12102A-FSGS-216-SS 586069020 L1-12102A-FSGS-217-SS 1205139809 Method Blank (MB) 1205139810 586069001(L1-12102A-FSGS-201-SS) Sample Duplicate (DUP) 1205139811 Laboratory Control Sample (LCS)
The samples in this SDG were analyzed on a "dry weight" basis.
Page 58 of 60 SDG: 586069
Data Summary:
There are no exceptions, anomalies or deviations from the specified methods. All sample data provided in this report met the acceptance criteria specified in the analytical methods and procedures for initial calibration, continuing calibration, instrument controls and process controls where applicable.
Qualifier Information Qualifier Reason Analyte Sample Client Sample UI Results are considered a false positive due to high counting uncertainty.
Bismuth-211 586069002 L1-12102A-FSGS-202-SS Bismuth-211 586069015 L1-12102A-FSGS-212-SS Bismuth-211 586069016 L1-12102A-FSGS-213-SS Bismuth-211 586069017 L1-12102A-FSGS-214-SS Bismuth-211 586069020 L1-12102A-FSGS-217-SS Bismuth-211 1205139810 L1-12102A-FSGS-201-SS(586069001DUP)
Thallium-208 586069011 L1-12102A-FSGS-210-SS UI Results are considered a false positive due to low abundance.
Bismuth-211 586069001 L1-12102A-FSGS-201-SS Bismuth-211 586069003 L1-12102A-FSGS-203-SS Bismuth-211 586069004 L1-12102A-FSGS-204-SS Bismuth-211 586069006 L1-12102A-FQGS-205-SS Bismuth-211 586069007 L1-12102A-FSGS-206-SS Bismuth-211 586069009 L1-12102A-FSGS-208-SS Bismuth-211 586069010 L1-12102A-FSGS-209-SS Bismuth-211 586069012 L1-12102A-FSGS-210-SB Bismuth-211 586069014 L1-12102A-FSGS-211-SB Bismuth-211 586069018 L1-12102A-FSGS-215-SS Bismuth-211 586069019 L1-12102A-FSGS-216-SS Page 59 of 60 SDG: 586069
Cesium-134 586069002 L1-12102A-FSGS-202-SS Cesium-134 586069017 L1-12102A-FSGS-214-SS Product: Gammaspec, Gamma, Solid (Requested List)
Analytical Method: DOE HASL 300, 4.5.2.3/Ga-01-R Analytical Procedure: GL-RAD-A-013 REV# 27 Analytical Batch: 2290067 Preparation Method: Dry Soil Prep Preparation Procedure: GL-RAD-A-021 REV# 24 Preparation Batch: 2289907 The following samples were analyzed using the above methods and analytical procedure(s).
GEL Sample ID# Client Sample Identification 586069021 L1-12102A-FSGS-218-SS 1205139815 Method Blank (MB) 1205139816 586069021(L1-12102A-FSGS-218-SS) Sample Duplicate (DUP) 1205139817 Laboratory Control Sample (LCS)
The samples in this SDG were analyzed on a "dry weight" basis.
Data Summary:
There are no exceptions, anomalies or deviations from the specified methods. All sample data provided in this report met the acceptance criteria specified in the analytical methods and procedures for initial calibration, continuing calibration, instrument controls and process controls where applicable.
Qualifier Information Qualifier Reason Analyte Sample Client Sample UI Results are considered a false positive due to low abundance.
Bismuth-211 586069021 L1-12102A-FSGS-218-SS Bismuth-211 1205139816 L1-12102A-FSGS-218-SS(586069021DUP)
Certification Statement Where the analytical method has been performed under NELAP certification, the analysis has met all of the requirements of the NELAC standard unless otherwise noted in the analytical case narrative.
Page 60 of 60 SDG: 586069
Reviewed by USER_SIGN_HERE GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 (843) 5568171 www.gel.com Certificate of Analysis Report ENRG080 Zion Solutions (702793)
Client SDG: 590180 GEL Work Order: 590180 Where the analytical method has been performed under NELAP certification, the analysis has met all of the requirements of the NELAC standard unless qualified on the Certificate of Analysis.
The designation ND, if present, appears in the result column when the analyte concentration is not detected above the limit as defined in the U qualifier above.
This data report has been prepared and reviewed in accordance with GEL Laboratories LLC standard operating procedures. Please direct any questions to your Project Manager, Zachary Worsham.
The Qualifiers in this report are defined as follows:
- A quality control analyte recovery is outside of specified acceptance criteria
- Analyte is a Tracer compound
UI Gamma SpectroscopyUncertain identification for Page 2 of 44 SDG: 590180
Certificate of Analysis GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Rad Gamma Spec Analysis Rad Gas Flow Proportional Counting Rad Liquid Scintillation Analysis Parameter Result Units Qualifier Analyst Date Time Gammaspec, Gamma, Solid (Requested List) "Dry Weight Corrected" GFPC, Sr90, Solid "Dry Weight Corrected" Liquid Scint Ni63, Solid "Dry Weight Corrected" 2305714 2305650 2307619 1211 1505 0644 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g Actinium-228 Bismuth-211 Bismuth-212 Bismuth-214 Cesium-134 Cesium-137 Cobalt-60 Europium-152 Europium-154 Lead-212 Lead-214 Potassium-40 Thallium-208 Strontium-90 Nickel-63 08/19/22 08/26/22 08/30/22 MXR1 KP1 TXJ1 UI U
U U
U U
U U
0.101 0.305 0.475 0.0589 0.0361 0.0301 0.0361 0.0918 0.0927 0.0561 0.0639 0.319 0.0255 0.0403 9.17 RL 0.173 0.363 0.109 0.869 0.799 0.0425 19.5 DF Mr. Gerry Wood
Contact:
Zion Solutions Company :
100 Shiloh Blvd.
Zion, Illinois 60099 August 30, 2022 Report Date:
Address :
Zion Solutions Project:
590180001 Soil 15-JUN-22 22-JUL-22 L1-12201C-FIGS-201-SS ENRG08001 Project:
ENRG080 Client ID:
Client 0.232 0.000 0.243 0.212 0.0100 1.87 0.00784 0.0171
-0.0469 0.234 0.312 11.3 0.0995 0.0182
-0.134
+/-0.127
+/-0.230
+/-0.297
+/-0.0821
+/-0.0171
+/-0.0944
+/-0.0174
+/-0.0467
+/-0.0538
+/-0.0686
+/-0.0836
+/-0.866
+/-0.0415
+/-0.0236
+/-5.28 Sample ID:
Receive Date:
Client Sample ID:
Matrix:
Collect Date:
Collector:
Moisture:
Batch
.268%
The following Prep Methods were performed Dry Soil Prep Dry Soil Prep GL-RAD-A-021 07/22/22 2305626 1428 SF1 Method Description Analyst Date Time Prep Batch Mtd.
The following Analytical Methods were performed Method Description
+/-0.128
+/-0.457
+/-0.298
+/-0.0846
+/-0.0177
+/-0.203
+/-0.0178
+/-0.0474
+/-0.0579
+/-0.0711
+/-0.0876
+/-1.33
+/-0.0426
+/-0.0239
+/-5.28 1
2 3
DOE HASL 300, 4.5.2.3/Ga-01-R EPA 905.0 Modified/DOE RP501 Rev. 1 Modified DOE RESL Ni-1, Modified 1
2 3
Strontium Carrier Nickel Carrier GFPC, Sr90, Solid "Dry Weight Corrected" Liquid Scint Ni63, Solid "Dry Weight Corrected" 83.2 91.2 (25%-125%)
(25%-125%)
2305650 2307619 Acceptable Limits Test Recovery%
Batch ID Surrogate/Tracer Recovery MDC TPU Uncertainty PF Page 3 of 44 SDG: 590180
Certificate of Analysis GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Parameter Result Units Qualifier Analyst Date Time RL DF Mr. Gerry Wood
Contact:
Zion Solutions Company :
100 Shiloh Blvd.
Zion, Illinois 60099 August 30, 2022 Report Date:
Address :
Zion Solutions Project:
590180001 L1-12201C-FIGS-201-SS ENRG08001 Project:
ENRG080 Client ID:
Sample ID:
Client Sample ID:
Batch Mtd.
Notes:
The MDC is a sample specific MDC.
Acceptable Limits Test Recovery%
Batch ID Surrogate/Tracer Recovery MDC TPU Uncertainty TPU is calculated at the 95% confidence level (1.96-sigma).
PF Column headers are defined as follows:
DF: Dilution Factor DL: Detection Limit Lc/LC: Critical Level MDA: Minimum Detectable Activity MDC: Minimum Detectable Concentration Mtd.: Method PF: Prep Factor RL: Reporting Limit TPU: Total Propagated Uncertainty Page 4 of 44 SDG: 590180
Certificate of Analysis GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Rad Gamma Spec Analysis Rad Gas Flow Proportional Counting Rad Liquid Scintillation Analysis Parameter Result Units Qualifier Analyst Date Time Gammaspec, Gamma, Solid (Requested List) "Dry Weight Corrected" GFPC, Sr90, Solid "Dry Weight Corrected" Liquid Scint Ni63, Solid "Dry Weight Corrected" 2305714 2305650 2307619 1211 1505 0700 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g Actinium-228 Bismuth-211 Bismuth-212 Bismuth-214 Cesium-134 Cesium-137 Cobalt-60 Europium-152 Europium-154 Lead-212 Lead-214 Potassium-40 Thallium-208 Strontium-90 Nickel-63 08/19/22 08/26/22 08/30/22 MXR1 KP1 TXJ1 UI U
U U
U U
U U
0.180 0.425 0.666 0.0752 0.0437 0.0440 0.0607 0.115 0.168 0.0541 0.0863 0.503 0.0374 0.0401 8.70 RL 0.173 0.363 0.109 0.869 0.799 0.0425 19.5 DF Mr. Gerry Wood
Contact:
Zion Solutions Company :
100 Shiloh Blvd.
Zion, Illinois 60099 August 30, 2022 Report Date:
Address :
Zion Solutions Project:
590180002 Soil 15-JUN-22 22-JUL-22 L1-12201C-FIGS-201-SB ENRG08001 Project:
ENRG080 Client ID:
Client 0.297 0.000 0.268 0.387
-0.00548 1.33 0.0125 0.0385
-0.000340 0.357 0.353 13.9 0.111
-0.00699
-0.374
+/-0.167
+/-0.309
+/-0.331
+/-0.109
+/-0.0227
+/-0.111
+/-0.0303
+/-0.0562
+/-0.0896
+/-0.0671
+/-0.112
+/-1.20
+/-0.0481
+/-0.0198
+/-5.00 Sample ID:
Receive Date:
Client Sample ID:
Matrix:
Collect Date:
Collector:
Moisture:
Batch 7.23%
The following Prep Methods were performed Dry Soil Prep Dry Soil Prep GL-RAD-A-021 07/22/22 2305626 1428 SF1 Method Description Analyst Date Time Prep Batch Mtd.
The following Analytical Methods were performed Method Description
+/-0.170
+/-0.543
+/-0.353
+/-0.114
+/-0.0229
+/-0.156
+/-0.0308
+/-0.0589
+/-0.0896
+/-0.0737
+/-0.116
+/-1.80
+/-0.0490
+/-0.0198
+/-5.00 1
2 3
DOE HASL 300, 4.5.2.3/Ga-01-R EPA 905.0 Modified/DOE RP501 Rev. 1 Modified DOE RESL Ni-1, Modified 1
2 3
Strontium Carrier Nickel Carrier GFPC, Sr90, Solid "Dry Weight Corrected" Liquid Scint Ni63, Solid "Dry Weight Corrected" 62.4 90.8 (25%-125%)
(25%-125%)
2305650 2307619 Acceptable Limits Test Recovery%
Batch ID Surrogate/Tracer Recovery MDC TPU Uncertainty PF Page 5 of 44 SDG: 590180
Certificate of Analysis GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Parameter Result Units Qualifier Analyst Date Time RL DF Mr. Gerry Wood
Contact:
Zion Solutions Company :
100 Shiloh Blvd.
Zion, Illinois 60099 August 30, 2022 Report Date:
Address :
Zion Solutions Project:
590180002 L1-12201C-FIGS-201-SB ENRG08001 Project:
ENRG080 Client ID:
Sample ID:
Client Sample ID:
Batch Mtd.
Notes:
The MDC is a sample specific MDC.
Acceptable Limits Test Recovery%
Batch ID Surrogate/Tracer Recovery MDC TPU Uncertainty TPU is calculated at the 95% confidence level (1.96-sigma).
PF Column headers are defined as follows:
DF: Dilution Factor DL: Detection Limit Lc/LC: Critical Level MDA: Minimum Detectable Activity MDC: Minimum Detectable Concentration Mtd.: Method PF: Prep Factor RL: Reporting Limit TPU: Total Propagated Uncertainty Page 6 of 44 SDG: 590180
Certificate of Analysis GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Rad Gamma Spec Analysis Rad Gas Flow Proportional Counting Rad Liquid Scintillation Analysis Parameter Result Units Qualifier Analyst Date Time Gammaspec, Gamma, Solid (Requested List) "Dry Weight Corrected" GFPC, Sr90, Solid "Dry Weight Corrected" Liquid Scint Ni63, Solid "Dry Weight Corrected" 2305714 2305650 2307619 1212 1505 0715 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g Actinium-228 Bismuth-211 Bismuth-212 Bismuth-214 Cesium-134 Cesium-137 Cobalt-60 Europium-152 Europium-154 Lead-212 Lead-214 Potassium-40 Thallium-208 Strontium-90 Nickel-63 08/19/22 08/26/22 08/30/22 MXR1 KP1 TXJ1 UI U
U U
U U
U U
0.102 0.274 0.348 0.0601 0.0294 0.0263 0.0283 0.0657 0.0937 0.0437 0.0563 0.212 0.0260 0.0394 8.86 RL 0.173 0.363 0.109 0.869 0.799 0.0425 19.5 DF Mr. Gerry Wood
Contact:
Zion Solutions Company :
100 Shiloh Blvd.
Zion, Illinois 60099 August 30, 2022 Report Date:
Address :
Zion Solutions Project:
590180003 Soil 12-JUL-22 22-JUL-22 L1-12201C-FIGS-202-SS ENRG08001 Project:
ENRG080 Client ID:
Client 0.328 0.000 0.463 0.273 0.00158
-0.00603
-0.0115
-0.0172 0.0198 0.250 0.263 11.5 0.0898
-0.0148 2.33
+/-0.114
+/-0.222
+/-0.373
+/-0.0694
+/-0.0151
+/-0.0144
+/-0.0190
+/-0.0360
+/-0.0450
+/-0.0541
+/-0.0805
+/-0.843
+/-0.0341
+/-0.0190
+/-5.19 Sample ID:
Receive Date:
Client Sample ID:
Matrix:
Collect Date:
Collector:
Moisture:
Batch
.436%
The following Prep Methods were performed Dry Soil Prep Dry Soil Prep GL-RAD-A-021 07/22/22 2305626 1428 SF1 Method Description Analyst Date Time Prep Batch Mtd.
The following Analytical Methods were performed Method Description
+/-0.119
+/-0.399
+/-0.375
+/-0.0732
+/-0.0151
+/-0.0147
+/-0.0197
+/-0.0369
+/-0.0459
+/-0.0578
+/-0.0834
+/-1.39
+/-0.0349
+/-0.0190
+/-5.21 1
2 3
DOE HASL 300, 4.5.2.3/Ga-01-R EPA 905.0 Modified/DOE RP501 Rev. 1 Modified DOE RESL Ni-1, Modified 1
2 3
Strontium Carrier Nickel Carrier GFPC, Sr90, Solid "Dry Weight Corrected" Liquid Scint Ni63, Solid "Dry Weight Corrected" 87.9 90.8 (25%-125%)
(25%-125%)
2305650 2307619 Acceptable Limits Test Recovery%
Batch ID Surrogate/Tracer Recovery MDC TPU Uncertainty PF Page 7 of 44 SDG: 590180
Certificate of Analysis GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Parameter Result Units Qualifier Analyst Date Time RL DF Mr. Gerry Wood
Contact:
Zion Solutions Company :
100 Shiloh Blvd.
Zion, Illinois 60099 August 30, 2022 Report Date:
Address :
Zion Solutions Project:
590180003 L1-12201C-FIGS-202-SS ENRG08001 Project:
ENRG080 Client ID:
Sample ID:
Client Sample ID:
Batch Mtd.
Notes:
The MDC is a sample specific MDC.
Acceptable Limits Test Recovery%
Batch ID Surrogate/Tracer Recovery MDC TPU Uncertainty TPU is calculated at the 95% confidence level (1.96-sigma).
PF Column headers are defined as follows:
DF: Dilution Factor DL: Detection Limit Lc/LC: Critical Level MDA: Minimum Detectable Activity MDC: Minimum Detectable Concentration Mtd.: Method PF: Prep Factor RL: Reporting Limit TPU: Total Propagated Uncertainty Page 8 of 44 SDG: 590180
Certificate of Analysis GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Rad Gamma Spec Analysis Rad Gas Flow Proportional Counting Rad Liquid Scintillation Analysis Parameter Result Units Qualifier Analyst Date Time Gammaspec, Gamma, Solid (Requested List) "Dry Weight Corrected" GFPC, Sr90, Solid "Dry Weight Corrected" Liquid Scint Ni63, Solid "Dry Weight Corrected" 2305714 2305650 2307619 1212 1506 0731 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g Actinium-228 Bismuth-211 Bismuth-212 Bismuth-214 Cesium-134 Cesium-137 Cobalt-60 Europium-152 Europium-154 Lead-212 Lead-214 Potassium-40 Thallium-208 Strontium-90 Nickel-63 08/19/22 08/26/22 08/30/22 MXR1 KP1 TXJ1 U
U U
U U
U U
U U
0.148 0.203 0.502 0.0820 0.0488 0.0384 0.0395 0.0950 0.144 0.0556 0.180 0.369 0.0371 0.0400 10.7 RL 0.173 0.363 0.109 0.869 0.799 0.0425 19.5 DF Mr. Gerry Wood
Contact:
Zion Solutions Company :
100 Shiloh Blvd.
Zion, Illinois 60099 August 30, 2022 Report Date:
Address :
Zion Solutions Project:
590180004 Soil 06-JUL-22 22-JUL-22 L1-12201D-FIGS-303-SS ENRG08001 Project:
ENRG080 Client ID:
Client 0.505 0.161 0.464 0.477 0.0362 0.00395
-0.00585
-0.00554
-0.00219 0.429 0.636 14.7 0.104
-0.0247 3.47
+/-0.162
+/-0.535
+/-0.523
+/-0.0988
+/-0.0234
+/-0.0201
+/-0.0209
+/-0.0499
+/-0.0757
+/-0.0703
+/-0.106
+/-1.11
+/-0.0462
+/-0.0180
+/-6.30 Sample ID:
Receive Date:
Client Sample ID:
Matrix:
Collect Date:
Collector:
Moisture:
Batch 10.6%
The following Prep Methods were performed Dry Soil Prep Dry Soil Prep GL-RAD-A-021 07/22/22 2305626 1428 SF1 Method Description Analyst Date Time Prep Batch Mtd.
The following Analytical Methods were performed Method Description
+/-0.170
+/-0.565
+/-0.524
+/-0.107
+/-0.0287
+/-0.0202
+/-0.0211
+/-0.0500
+/-0.0757
+/-0.0783
+/-0.119
+/-1.75
+/-0.0471
+/-0.0180
+/-6.33 1
2 3
DOE HASL 300, 4.5.2.3/Ga-01-R EPA 905.0 Modified/DOE RP501 Rev. 1 Modified DOE RESL Ni-1, Modified 1
2 3
Strontium Carrier Nickel Carrier GFPC, Sr90, Solid "Dry Weight Corrected" Liquid Scint Ni63, Solid "Dry Weight Corrected" 90.2 68.6 (25%-125%)
(25%-125%)
2305650 2307619 Acceptable Limits Test Recovery%
Batch ID Surrogate/Tracer Recovery MDC TPU Uncertainty PF Page 9 of 44 SDG: 590180
Certificate of Analysis GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Parameter Result Units Qualifier Analyst Date Time RL DF Mr. Gerry Wood
Contact:
Zion Solutions Company :
100 Shiloh Blvd.
Zion, Illinois 60099 August 30, 2022 Report Date:
Address :
Zion Solutions Project:
590180004 L1-12201D-FIGS-303-SS ENRG08001 Project:
ENRG080 Client ID:
Sample ID:
Client Sample ID:
Batch Mtd.
Notes:
The MDC is a sample specific MDC.
Acceptable Limits Test Recovery%
Batch ID Surrogate/Tracer Recovery MDC TPU Uncertainty TPU is calculated at the 95% confidence level (1.96-sigma).
PF Column headers are defined as follows:
DF: Dilution Factor DL: Detection Limit Lc/LC: Critical Level MDA: Minimum Detectable Activity MDC: Minimum Detectable Concentration Mtd.: Method PF: Prep Factor RL: Reporting Limit TPU: Total Propagated Uncertainty Page 10 of 44 SDG: 590180
Certificate of Analysis GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Rad Gamma Spec Analysis Rad Gas Flow Proportional Counting Rad Liquid Scintillation Analysis Parameter Result Units Qualifier Analyst Date Time Gammaspec, Gamma, Solid (Requested List) "Dry Weight Corrected" GFPC, Sr90, Solid "Dry Weight Corrected" Liquid Scint Ni63, Solid "Dry Weight Corrected" 2305714 2305650 2307619 1212 1506 0747 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g Actinium-228 Bismuth-211 Bismuth-212 Bismuth-214 Cesium-134 Cesium-137 Cobalt-60 Europium-152 Europium-154 Lead-212 Lead-214 Potassium-40 Thallium-208 Strontium-90 Nickel-63 08/19/22 08/26/22 08/30/22 MXR1 KP1 TXJ1 UI U
U U
U U
U U
U 0.198 0.286 0.458 0.0589 0.0323 0.0316 0.0286 0.0704 0.0879 0.0408 0.0558 0.264 0.0231 0.0351 7.97 RL 0.173 0.363 0.109 0.869 0.799 0.0425 19.5 DF Mr. Gerry Wood
Contact:
Zion Solutions Company :
100 Shiloh Blvd.
Zion, Illinois 60099 August 30, 2022 Report Date:
Address :
Zion Solutions Project:
590180005 Soil 06-JUL-22 22-JUL-22 L1-12201E-FIGS-202-SS ENRG08001 Project:
ENRG080 Client ID:
Client 0.252 0.000 0.0883 0.255
-0.00123 0.00436 0.000808
-0.000148
-0.0303 0.237 0.252 10.0 0.0782 0.0259
-1.82
+/-0.133
+/-0.194
+/-0.233
+/-0.0727
+/-0.0172
+/-0.0160
+/-0.0136
+/-0.0372
+/-0.0489
+/-0.0502
+/-0.0705
+/-0.865
+/-0.0274
+/-0.0216
+/-4.52 Sample ID:
Receive Date:
Client Sample ID:
Matrix:
Collect Date:
Collector:
Moisture:
Batch 4.75%
The following Prep Methods were performed Dry Soil Prep Dry Soil Prep GL-RAD-A-021 07/22/22 2305626 1428 SF1 Method Description Analyst Date Time Prep Batch Mtd.
The following Analytical Methods were performed Method Description
+/-0.177
+/-0.373
+/-0.237
+/-0.0760
+/-0.0172
+/-0.0161
+/-0.0136
+/-0.0372
+/-0.0508
+/-0.0540
+/-0.0736
+/-1.28
+/-0.0282
+/-0.0221
+/-4.52 1
2 3
DOE HASL 300, 4.5.2.3/Ga-01-R EPA 905.0 Modified/DOE RP501 Rev. 1 Modified DOE RESL Ni-1, Modified 1
2 3
Strontium Carrier Nickel Carrier GFPC, Sr90, Solid "Dry Weight Corrected" Liquid Scint Ni63, Solid "Dry Weight Corrected" 116 93.9 (25%-125%)
(25%-125%)
2305650 2307619 Acceptable Limits Test Recovery%
Batch ID Surrogate/Tracer Recovery MDC TPU Uncertainty PF Page 11 of 44 SDG: 590180
Certificate of Analysis GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Parameter Result Units Qualifier Analyst Date Time RL DF Mr. Gerry Wood
Contact:
Zion Solutions Company :
100 Shiloh Blvd.
Zion, Illinois 60099 August 30, 2022 Report Date:
Address :
Zion Solutions Project:
590180005 L1-12201E-FIGS-202-SS ENRG08001 Project:
ENRG080 Client ID:
Sample ID:
Client Sample ID:
Batch Mtd.
Notes:
The MDC is a sample specific MDC.
Acceptable Limits Test Recovery%
Batch ID Surrogate/Tracer Recovery MDC TPU Uncertainty TPU is calculated at the 95% confidence level (1.96-sigma).
PF Column headers are defined as follows:
DF: Dilution Factor DL: Detection Limit Lc/LC: Critical Level MDA: Minimum Detectable Activity MDC: Minimum Detectable Concentration Mtd.: Method PF: Prep Factor RL: Reporting Limit TPU: Total Propagated Uncertainty Page 12 of 44 SDG: 590180
Certificate of Analysis GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Rad Gamma Spec Analysis Rad Gas Flow Proportional Counting Rad Liquid Scintillation Analysis Parameter Result Units Qualifier Analyst Date Time Gammaspec, Gamma, Solid (Requested List) "Dry Weight Corrected" GFPC, Sr90, Solid "Dry Weight Corrected" Liquid Scint Ni63, Solid "Dry Weight Corrected" 2305714 2305650 2307619 1213 1506 0802 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g Actinium-228 Bismuth-211 Bismuth-212 Bismuth-214 Cesium-134 Cesium-137 Cobalt-60 Europium-152 Europium-154 Lead-212 Lead-214 Potassium-40 Thallium-208 Strontium-90 Nickel-63 08/19/22 08/26/22 08/30/22 MXR1 KP1 TXJ1 U
U U
U U
U U
U 0.399 0.273 0.872 0.118 0.0791 0.0581 0.0478 0.137 0.213 0.0846 0.189 0.510 0.0555 0.0397 7.98 RL 0.173 0.363 0.109 0.869 0.799 0.0425 19.5 DF Mr. Gerry Wood
Contact:
Zion Solutions Company :
100 Shiloh Blvd.
Zion, Illinois 60099 August 30, 2022 Report Date:
Address :
Zion Solutions Project:
590180006 Soil 02-JUL-22 22-JUL-22 L1-12102A-FIGS-201-SB ENRG08001 Project:
ENRG080 Client ID:
Client 0.384 0.0982 0.200 0.371 0.00942 0.0673 0.869 0.0397 0.000804 0.300 0.340 10.2 0.0929
-0.00374 2.99
+/-0.297
+/-0.643
+/-0.443
+/-0.138
+/-0.0419
+/-0.0471
+/-0.112
+/-0.0688
+/-0.125
+/-0.0978
+/-0.137
+/-1.26
+/-0.0651
+/-0.0207
+/-4.71 Sample ID:
Receive Date:
Client Sample ID:
Matrix:
Collect Date:
Collector:
Moisture:
Batch 3.73%
The following Prep Methods were performed Dry Soil Prep Dry Soil Prep GL-RAD-A-021 07/22/22 2305626 1428 SF1 Method Description Analyst Date Time Prep Batch Mtd.
The following Analytical Methods were performed Method Description
+/-0.345
+/-0.649
+/-0.453
+/-0.142
+/-0.0421
+/-0.0474
+/-0.134
+/-0.0711
+/-0.125
+/-0.101
+/-0.140
+/-1.57
+/-0.0656
+/-0.0207
+/-4.74 1
2 3
DOE HASL 300, 4.5.2.3/Ga-01-R EPA 905.0 Modified/DOE RP501 Rev. 1 Modified DOE RESL Ni-1, Modified 1
2 3
Strontium Carrier Nickel Carrier GFPC, Sr90, Solid "Dry Weight Corrected" Liquid Scint Ni63, Solid "Dry Weight Corrected" 67.1 90.8 (25%-125%)
(25%-125%)
2305650 2307619 Acceptable Limits Test Recovery%
Batch ID Surrogate/Tracer Recovery MDC TPU Uncertainty PF Page 13 of 44 SDG: 590180
Certificate of Analysis GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Parameter Result Units Qualifier Analyst Date Time RL DF Mr. Gerry Wood
Contact:
Zion Solutions Company :
100 Shiloh Blvd.
Zion, Illinois 60099 August 30, 2022 Report Date:
Address :
Zion Solutions Project:
590180006 L1-12102A-FIGS-201-SB ENRG08001 Project:
ENRG080 Client ID:
Sample ID:
Client Sample ID:
Batch Mtd.
Notes:
The MDC is a sample specific MDC.
Acceptable Limits Test Recovery%
Batch ID Surrogate/Tracer Recovery MDC TPU Uncertainty TPU is calculated at the 95% confidence level (1.96-sigma).
PF Column headers are defined as follows:
DF: Dilution Factor DL: Detection Limit Lc/LC: Critical Level MDA: Minimum Detectable Activity MDC: Minimum Detectable Concentration Mtd.: Method PF: Prep Factor RL: Reporting Limit TPU: Total Propagated Uncertainty Page 14 of 44 SDG: 590180
Certificate of Analysis GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Rad Gamma Spec Analysis Rad Gas Flow Proportional Counting Rad Liquid Scintillation Analysis Parameter Result Units Qualifier Analyst Date Time Gammaspec, Gamma, Solid (Requested List) "Dry Weight Corrected" GFPC, Sr90, Solid "Dry Weight Corrected" Liquid Scint Ni63, Solid "Dry Weight Corrected" 2305714 2305650 2307619 1214 1506 0818 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g Actinium-228 Bismuth-211 Bismuth-212 Bismuth-214 Cesium-134 Cesium-137 Cobalt-60 Europium-152 Europium-154 Lead-212 Lead-214 Potassium-40 Thallium-208 Strontium-90 Nickel-63 08/19/22 08/26/22 08/30/22 MXR1 KP1 TXJ1 UI UI U
U U
U U
0.126 0.318 0.348 0.0628 0.0363 0.0351 0.0355 0.0813 0.110 0.0446 0.0600 0.313 0.0231 0.0357 8.98 RL 0.173 0.363 0.109 0.869 0.799 0.0425 19.5 DF Mr. Gerry Wood
Contact:
Zion Solutions Company :
100 Shiloh Blvd.
Zion, Illinois 60099 August 30, 2022 Report Date:
Address :
Zion Solutions Project:
590180007 Soil 11-JUL-22 22-JUL-22 L1-12102A-FIGS-202-SS ENRG08001 Project:
ENRG080 Client ID:
Client 0.158 0.000 0.000 0.278
-0.00156 0.0462 0.110 0.0195 0.00449 0.284 0.331 10.7 0.0790 0.0156 1.42
+/-0.121
+/-0.226
+/-0.393
+/-0.0745
+/-0.0191
+/-0.0336
+/-0.0415
+/-0.0384
+/-0.0538
+/-0.0566
+/-0.0820
+/-0.982
+/-0.0364
+/-0.0210
+/-5.23 Sample ID:
Receive Date:
Client Sample ID:
Matrix:
Collect Date:
Collector:
Moisture:
Batch 2.94%
The following Prep Methods were performed Dry Soil Prep Dry Soil Prep GL-RAD-A-021 07/22/22 2305626 1428 SF1 Method Description Analyst Date Time Prep Batch Mtd.
The following Analytical Methods were performed Method Description
+/-0.123
+/-0.475
+/-0.400
+/-0.0783
+/-0.0191
+/-0.0338
+/-0.0428
+/-0.0395
+/-0.0538
+/-0.0612
+/-0.0862
+/-1.44
+/-0.0370
+/-0.0212
+/-5.24 1
2 3
DOE HASL 300, 4.5.2.3/Ga-01-R EPA 905.0 Modified/DOE RP501 Rev. 1 Modified DOE RESL Ni-1, Modified 1
2 3
Strontium Carrier Nickel Carrier GFPC, Sr90, Solid "Dry Weight Corrected" Liquid Scint Ni63, Solid "Dry Weight Corrected" 118 91.7 (25%-125%)
(25%-125%)
2305650 2307619 Acceptable Limits Test Recovery%
Batch ID Surrogate/Tracer Recovery MDC TPU Uncertainty PF Page 15 of 44 SDG: 590180
Certificate of Analysis GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Parameter Result Units Qualifier Analyst Date Time RL DF Mr. Gerry Wood
Contact:
Zion Solutions Company :
100 Shiloh Blvd.
Zion, Illinois 60099 August 30, 2022 Report Date:
Address :
Zion Solutions Project:
590180007 L1-12102A-FIGS-202-SS ENRG08001 Project:
ENRG080 Client ID:
Sample ID:
Client Sample ID:
Batch Mtd.
Notes:
The MDC is a sample specific MDC.
Acceptable Limits Test Recovery%
Batch ID Surrogate/Tracer Recovery MDC TPU Uncertainty TPU is calculated at the 95% confidence level (1.96-sigma).
PF Column headers are defined as follows:
DF: Dilution Factor DL: Detection Limit Lc/LC: Critical Level MDA: Minimum Detectable Activity MDC: Minimum Detectable Concentration Mtd.: Method PF: Prep Factor RL: Reporting Limit TPU: Total Propagated Uncertainty Page 16 of 44 SDG: 590180
Certificate of Analysis GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Rad Gamma Spec Analysis Rad Gas Flow Proportional Counting Rad Liquid Scintillation Analysis Parameter Result Units Qualifier Analyst Date Time Gammaspec, Gamma, Solid (Requested List) "Dry Weight Corrected" GFPC, Sr90, Solid "Dry Weight Corrected" Liquid Scint Ni63, Solid "Dry Weight Corrected" 2305714 2305650 2307619 1353 1506 0834 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g Actinium-228 Bismuth-211 Bismuth-212 Bismuth-214 Cesium-134 Cesium-137 Cobalt-60 Europium-152 Europium-154 Lead-212 Lead-214 Potassium-40 Thallium-208 Strontium-90 Nickel-63 08/19/22 08/26/22 08/30/22 MXR1 KP1 TXJ1 UI U
U U
U U
U U
U 0.152 0.488 0.680 0.0775 0.0550 0.0517 0.0364 0.107 0.155 0.0557 0.0821 0.393 0.0405 0.0344 8.68 RL 0.173 0.363 0.109 0.869 0.799 0.0425 19.5 DF Mr. Gerry Wood
Contact:
Zion Solutions Company :
100 Shiloh Blvd.
Zion, Illinois 60099 August 30, 2022 Report Date:
Address :
Zion Solutions Project:
590180008 Soil 11-JUL-22 22-JUL-22 L1-12102A-FIGS-206-SS ENRG08001 Project:
ENRG080 Client ID:
Client 0.316 0.000 0.304 0.382 0.0315 0.0231
-0.0102 0.00446
-0.0183 0.420 0.510 11.8 0.0793
-0.00985
-0.0436
+/-0.197
+/-0.354
+/-0.355
+/-0.118
+/-0.0397
+/-0.0248
+/-0.0197
+/-0.0591
+/-0.0817
+/-0.0725
+/-0.129
+/-1.18
+/-0.0534
+/-0.0174
+/-5.00 Sample ID:
Receive Date:
Client Sample ID:
Matrix:
Collect Date:
Collector:
Moisture:
Batch 2.2%
The following Prep Methods were performed Dry Soil Prep Dry Soil Prep GL-RAD-A-021 07/22/22 2305626 1440 SF1 Method Description Analyst Date Time Prep Batch Mtd.
The following Analytical Methods were performed Method Description
+/-0.200
+/-0.737
+/-0.381
+/-0.122
+/-0.0422
+/-0.0269
+/-0.0203
+/-0.0591
+/-0.0822
+/-0.0828
+/-0.136
+/-1.68
+/-0.0538
+/-0.0174
+/-5.00 1
2 3
DOE HASL 300, 4.5.2.3/Ga-01-R EPA 905.0 Modified/DOE RP501 Rev. 1 Modified DOE RESL Ni-1, Modified 1
2 3
Strontium Carrier Nickel Carrier GFPC, Sr90, Solid "Dry Weight Corrected" Liquid Scint Ni63, Solid "Dry Weight Corrected" 109 89 (25%-125%)
(25%-125%)
2305650 2307619 Acceptable Limits Test Recovery%
Batch ID Surrogate/Tracer Recovery MDC TPU Uncertainty PF Page 17 of 44 SDG: 590180
Certificate of Analysis GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Parameter Result Units Qualifier Analyst Date Time RL DF Mr. Gerry Wood
Contact:
Zion Solutions Company :
100 Shiloh Blvd.
Zion, Illinois 60099 August 30, 2022 Report Date:
Address :
Zion Solutions Project:
590180008 L1-12102A-FIGS-206-SS ENRG08001 Project:
ENRG080 Client ID:
Sample ID:
Client Sample ID:
Batch Mtd.
Notes:
The MDC is a sample specific MDC.
Acceptable Limits Test Recovery%
Batch ID Surrogate/Tracer Recovery MDC TPU Uncertainty TPU is calculated at the 95% confidence level (1.96-sigma).
PF Column headers are defined as follows:
DF: Dilution Factor DL: Detection Limit Lc/LC: Critical Level MDA: Minimum Detectable Activity MDC: Minimum Detectable Concentration Mtd.: Method PF: Prep Factor RL: Reporting Limit TPU: Total Propagated Uncertainty Page 18 of 44 SDG: 590180
Certificate of Analysis GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Rad Gamma Spec Analysis Rad Gas Flow Proportional Counting Rad Liquid Scintillation Analysis Parameter Result Units Qualifier Analyst Date Time Gammaspec, Gamma, Solid (Requested List) "Dry Weight Corrected" GFPC, Sr90, Solid "Dry Weight Corrected" Liquid Scint Ni63, Solid "Dry Weight Corrected" 2305714 2305650 2307619 1354 1506 0849 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g Actinium-228 Bismuth-211 Bismuth-212 Bismuth-214 Cesium-134 Cesium-137 Cobalt-60 Europium-152 Europium-154 Lead-212 Lead-214 Potassium-40 Thallium-208 Strontium-90 Nickel-63 08/19/22 08/26/22 08/30/22 MXR1 KP1 TXJ1 U
U U
U U
U U
U 0.150 0.208 0.701 0.0816 0.0447 0.0393 0.0484 0.0987 0.139 0.0668 0.155 0.354 0.0384 0.0405 8.98 RL 0.173 0.363 0.109 0.869 0.799 0.0425 19.5 DF Mr. Gerry Wood
Contact:
Zion Solutions Company :
100 Shiloh Blvd.
Zion, Illinois 60099 August 30, 2022 Report Date:
Address :
Zion Solutions Project:
590180009 Soil 27-JUN-22 22-JUL-22 L1-12103A-FIGS-301-SS ENRG08001 Project:
ENRG080 Client ID:
Client 0.522 0.126 0.569 0.285
-0.00855 0.0636 0.0195 0.00997 0.0341 0.354 0.360 7.74 0.150
-0.00367 1.28
+/-0.142
+/-0.569
+/-0.306
+/-0.119
+/-0.0242
+/-0.0456
+/-0.0204
+/-0.0534
+/-0.0635
+/-0.0785
+/-0.105
+/-0.844
+/-0.0482
+/-0.0210
+/-5.22 Sample ID:
Receive Date:
Client Sample ID:
Matrix:
Collect Date:
Collector:
Moisture:
Batch 1.96%
The following Prep Methods were performed Dry Soil Prep Dry Soil Prep GL-RAD-A-021 07/22/22 2305626 1440 SF1 Method Description Analyst Date Time Prep Batch Mtd.
The following Analytical Methods were performed Method Description
+/-0.150
+/-0.578
+/-0.402
+/-0.121
+/-0.0245
+/-0.0459
+/-0.0223
+/-0.0536
+/-0.0654
+/-0.0849
+/-0.109
+/-1.11
+/-0.0498
+/-0.0211
+/-5.23 1
2 3
DOE HASL 300, 4.5.2.3/Ga-01-R EPA 905.0 Modified/DOE RP501 Rev. 1 Modified DOE RESL Ni-1, Modified 1
2 3
Strontium Carrier Nickel Carrier GFPC, Sr90, Solid "Dry Weight Corrected" Liquid Scint Ni63, Solid "Dry Weight Corrected" 83.2 90.3 (25%-125%)
(25%-125%)
2305650 2307619 Acceptable Limits Test Recovery%
Batch ID Surrogate/Tracer Recovery MDC TPU Uncertainty PF Page 19 of 44 SDG: 590180
Certificate of Analysis GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Parameter Result Units Qualifier Analyst Date Time RL DF Mr. Gerry Wood
Contact:
Zion Solutions Company :
100 Shiloh Blvd.
Zion, Illinois 60099 August 30, 2022 Report Date:
Address :
Zion Solutions Project:
590180009 L1-12103A-FIGS-301-SS ENRG08001 Project:
ENRG080 Client ID:
Sample ID:
Client Sample ID:
Batch Mtd.
Notes:
The MDC is a sample specific MDC.
Acceptable Limits Test Recovery%
Batch ID Surrogate/Tracer Recovery MDC TPU Uncertainty TPU is calculated at the 95% confidence level (1.96-sigma).
PF Column headers are defined as follows:
DF: Dilution Factor DL: Detection Limit Lc/LC: Critical Level MDA: Minimum Detectable Activity MDC: Minimum Detectable Concentration Mtd.: Method PF: Prep Factor RL: Reporting Limit TPU: Total Propagated Uncertainty Page 20 of 44 SDG: 590180
Certificate of Analysis GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Rad Gamma Spec Analysis Rad Gas Flow Proportional Counting Rad Liquid Scintillation Analysis Parameter Result Units Qualifier Analyst Date Time Gammaspec, Gamma, Solid (Requested List) "Dry Weight Corrected" GFPC, Sr90, Solid "Dry Weight Corrected" Liquid Scint Ni63, Solid "Dry Weight Corrected" 2305714 2305650 2307619 1354 1506 0905 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g Actinium-228 Bismuth-211 Bismuth-212 Bismuth-214 Cesium-134 Cesium-137 Cobalt-60 Europium-152 Europium-154 Lead-212 Lead-214 Potassium-40 Thallium-208 Strontium-90 Nickel-63 08/19/22 08/26/22 08/30/22 MXR1 KP1 TXJ1 UI U
U U
U U
U U
0.115 0.383 0.511 0.0694 0.0438 0.0331 0.0350 0.0968 0.110 0.0493 0.0698 0.247 0.0331 0.0413 9.14 RL 0.173 0.363 0.109 0.869 0.799 0.0425 19.5 DF Mr. Gerry Wood
Contact:
Zion Solutions Company :
100 Shiloh Blvd.
Zion, Illinois 60099 August 30, 2022 Report Date:
Address :
Zion Solutions Project:
590180010 Soil 27-JUN-22 22-JUL-22 L1-12103A-FIGS-301-SB ENRG08001 Project:
ENRG080 Client ID:
Client 0.239 0.000 0.134 0.326 0.0171 0.0453
-0.00926 0.0112 0.0175 0.330 0.386 9.34 0.120 0.0316 0.704
+/-0.133
+/-0.269
+/-0.255
+/-0.0871
+/-0.0293
+/-0.0296
+/-0.0192
+/-0.0509
+/-0.0518
+/-0.0633
+/-0.0975
+/-0.850
+/-0.0400
+/-0.0255
+/-5.29 Sample ID:
Receive Date:
Client Sample ID:
Matrix:
Collect Date:
Collector:
Moisture:
Batch 2.54%
The following Prep Methods were performed Dry Soil Prep Dry Soil Prep GL-RAD-A-021 07/22/22 2305626 1440 SF1 Method Description Analyst Date Time Prep Batch Mtd.
The following Analytical Methods were performed Method Description
+/-0.135
+/-0.557
+/-0.263
+/-0.0914
+/-0.0303
+/-0.0298
+/-0.0197
+/-0.0512
+/-0.0524
+/-0.0695
+/-0.103
+/-1.27
+/-0.0413
+/-0.0262
+/-5.29 1
2 3
DOE HASL 300, 4.5.2.3/Ga-01-R EPA 905.0 Modified/DOE RP501 Rev. 1 Modified DOE RESL Ni-1, Modified 1
2 3
Strontium Carrier Nickel Carrier GFPC, Sr90, Solid "Dry Weight Corrected" Liquid Scint Ni63, Solid "Dry Weight Corrected" 94.8 90.8 (25%-125%)
(25%-125%)
2305650 2307619 Acceptable Limits Test Recovery%
Batch ID Surrogate/Tracer Recovery MDC TPU Uncertainty PF Page 21 of 44 SDG: 590180
Certificate of Analysis GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Parameter Result Units Qualifier Analyst Date Time RL DF Mr. Gerry Wood
Contact:
Zion Solutions Company :
100 Shiloh Blvd.
Zion, Illinois 60099 August 30, 2022 Report Date:
Address :
Zion Solutions Project:
590180010 L1-12103A-FIGS-301-SB ENRG08001 Project:
ENRG080 Client ID:
Sample ID:
Client Sample ID:
Batch Mtd.
Notes:
The MDC is a sample specific MDC.
Acceptable Limits Test Recovery%
Batch ID Surrogate/Tracer Recovery MDC TPU Uncertainty TPU is calculated at the 95% confidence level (1.96-sigma).
PF Column headers are defined as follows:
DF: Dilution Factor DL: Detection Limit Lc/LC: Critical Level MDA: Minimum Detectable Activity MDC: Minimum Detectable Concentration Mtd.: Method PF: Prep Factor RL: Reporting Limit TPU: Total Propagated Uncertainty Page 22 of 44 SDG: 590180
Certificate of Analysis GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Rad Gamma Spec Analysis Rad Gas Flow Proportional Counting Rad Liquid Scintillation Analysis Parameter Result Units Qualifier Analyst Date Time Gammaspec, Gamma, Solid (Requested List) "Dry Weight Corrected" GFPC, Sr90, Solid "Dry Weight Corrected" Liquid Scint Ni63, Solid "Dry Weight Corrected" 2305714 2305650 2307619 1354 1506 0921 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g Actinium-228 Bismuth-211 Bismuth-212 Bismuth-214 Cesium-134 Cesium-137 Cobalt-60 Europium-152 Europium-154 Lead-212 Lead-214 Potassium-40 Thallium-208 Strontium-90 Nickel-63 08/19/22 08/26/22 08/30/22 MXR1 KP1 TXJ1 U
U UI U
U U
U U
0.119 0.159 0.522 0.0558 0.0460 0.0388 0.0467 0.0924 0.125 0.0496 0.125 0.259 0.0292 0.0413 9.13 RL 0.173 0.363 0.109 0.869 0.799 0.0425 19.5 DF Mr. Gerry Wood
Contact:
Zion Solutions Company :
100 Shiloh Blvd.
Zion, Illinois 60099 August 30, 2022 Report Date:
Address :
Zion Solutions Project:
590180011 Soil 11-JUL-22 22-JUL-22 L1-12103A-FIGS-302-SS ENRG08001 Project:
ENRG080 Client ID:
Client 0.287 0.0158 0.362 0.239 0.000 0.0740 0.0261 0.0275 0.0309 0.395 0.348 7.92 0.0913 0.0141 1.83
+/-0.165
+/-0.430
+/-0.230
+/-0.0896
+/-0.0260
+/-0.0350
+/-0.0198
+/-0.0440
+/-0.0596
+/-0.0718
+/-0.0726
+/-0.793
+/-0.0401
+/-0.0237
+/-5.33 Sample ID:
Receive Date:
Client Sample ID:
Matrix:
Collect Date:
Collector:
Moisture:
Batch 1.21%
The following Prep Methods were performed Dry Soil Prep Dry Soil Prep GL-RAD-A-021 07/22/22 2305626 1440 SF1 Method Description Analyst Date Time Prep Batch Mtd.
The following Analytical Methods were performed Method Description
+/-0.168
+/-0.444
+/-0.284
+/-0.0919
+/-0.0404
+/-0.0355
+/-0.0232
+/-0.0458
+/-0.0612
+/-0.0799
+/-0.0780
+/-1.11
+/-0.0408
+/-0.0239
+/-5.34 1
2 3
DOE HASL 300, 4.5.2.3/Ga-01-R EPA 905.0 Modified/DOE RP501 Rev. 1 Modified DOE RESL Ni-1, Modified 1
2 3
Strontium Carrier Nickel Carrier GFPC, Sr90, Solid "Dry Weight Corrected" Liquid Scint Ni63, Solid "Dry Weight Corrected" 46.2 90.3 (25%-125%)
(25%-125%)
2305650 2307619 Acceptable Limits Test Recovery%
Batch ID Surrogate/Tracer Recovery MDC TPU Uncertainty PF Page 23 of 44 SDG: 590180
Certificate of Analysis GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Parameter Result Units Qualifier Analyst Date Time RL DF Mr. Gerry Wood
Contact:
Zion Solutions Company :
100 Shiloh Blvd.
Zion, Illinois 60099 August 30, 2022 Report Date:
Address :
Zion Solutions Project:
590180011 L1-12103A-FIGS-302-SS ENRG08001 Project:
ENRG080 Client ID:
Sample ID:
Client Sample ID:
Batch Mtd.
Notes:
The MDC is a sample specific MDC.
Acceptable Limits Test Recovery%
Batch ID Surrogate/Tracer Recovery MDC TPU Uncertainty TPU is calculated at the 95% confidence level (1.96-sigma).
PF Column headers are defined as follows:
DF: Dilution Factor DL: Detection Limit Lc/LC: Critical Level MDA: Minimum Detectable Activity MDC: Minimum Detectable Concentration Mtd.: Method PF: Prep Factor RL: Reporting Limit TPU: Total Propagated Uncertainty Page 24 of 44 SDG: 590180
QC Summary GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Rad Gamma Spec 2305714 Batch Actinium-228 Bismuth-211 Bismuth-212 Bismuth-214 Cesium-134 Cesium-137 Cobalt-60 Europium-152 Europium-154 Lead-212 Lead-214 Potassium-40 Thallium-208 Americium-241 Parmname Mr. Gerry Wood
Contact:
Zion Solutions Client :
100 Shiloh Blvd.
Zion, Illinois August 30, 2022 Report Date:
Units pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g Anlst Date Time MXR1 MXR1 08/19/22 08/19/22 15:47 15:48 QC 0.290 0.000 0.444 0.235 0.0222 1.75
-0.00876
-0.0168 0.0567 0.205 0.255 10.5 0.101 510 NOM Sample 0.232 0.000 0.243 0.212 0.0100 1.87 0.00784 0.0171
-0.0469 0.234 0.312 11.3 0.0995 Range (0% - 100%)
N/A N/A (0% - 100%)
N/A (0%-20%)
N/A N/A N/A (0% - 100%)
(0% - 100%)
(0%-20%)
(0% - 100%)
(75%-125%)
Qual UI U
U U
U U
QC1205169263 590180001 QC1205169264 REC%
105 485 DUP LCS 590180 Workorder:
UI U
U U
U U
+/-0.127
+/-0.230
+/-0.297
+/-0.0821
+/-0.0171
+/-0.0944
+/-0.0174
+/-0.0467
+/-0.0538
+/-0.0686
+/-0.0836
+/-0.866
+/-0.0415
+/-0.153
+/-0.244
+/-0.449
+/-0.0828
+/-0.0232
+/-0.107
+/-0.0192
+/-0.0476
+/-0.104
+/-0.0664
+/-0.0885
+/-0.975
+/-0.0369 Uncert:
Uncert:
Uncert:
Uncert:
Uncert:
Uncert:
Uncert:
Uncert:
Uncert:
Uncert:
Uncert:
Uncert:
Uncert:
TPU:
TPU:
TPU:
TPU:
TPU:
TPU:
TPU:
TPU:
TPU:
TPU:
TPU:
TPU:
TPU:
+/-0.128
+/-0.457
+/-0.298
+/-0.0846
+/-0.0177
+/-0.203
+/-0.0178
+/-0.0474
+/-0.0579
+/-0.0711
+/-0.0876
+/-1.33
+/-0.0426
+/-0.203
+/-0.404
+/-0.450
+/-0.0852
+/-0.0254
+/-0.180
+/-0.0196
+/-0.0482
+/-0.107
+/-0.0688
+/-0.0911
+/-1.40
+/-0.0379 22.2 0
0 10 0
6.58 0
0 0
13.2 20.1 7.99 1.82 RPD%
Page 1 of 5 Page 25 of 44 SDG: 590180
QC Summary GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Rad Gamma Spec 2305714 Batch Actinium-228 Bismuth-211 Bismuth-212 Bismuth-214 Cesium-134 Cesium-137 Cobalt-60 Europium-152 Europium-154 Lead-212 Lead-214 Potassium-40 Thallium-208 Actinium-228 Bismuth-211 Parmname Units pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g Anlst Date Time MXR1 08/19/2215:47 QC 0.459 0.321 7.54 0.118 0.159 157 74.6
-0.297
-0.0848 0.0510
-0.515
-0.807 0.178
-0.135
-0.0571 NOM Sample Range (75%-125%)
(75%-125%)
Qual U
U U
U U
U U
U U
U U
U QC1205169262 REC%
100 99.8 157 74.7 MB 590180 Workorder:
+/-9.64
+/-1.60
+/-2.10
+/-6.92
+/-0.624
+/-0.357
+/-2.39
+/-2.06
+/-1.06
+/-0.593
+/-0.540
+/-0.776
+/-1.36
+/-0.326
+/-0.0997 Uncert:
Uncert:
Uncert:
Uncert:
Uncert:
Uncert:
Uncert:
Uncert:
Uncert:
Uncert:
Uncert:
Uncert:
Uncert:
Uncert:
Uncert:
TPU:
TPU:
TPU:
TPU:
TPU:
TPU:
TPU:
TPU:
TPU:
TPU:
TPU:
TPU:
TPU:
TPU:
TPU:
+/-48.8
+/-1.62
+/-2.10
+/-6.96
+/-0.626
+/-0.365
+/-14.8
+/-6.54
+/-1.07
+/-0.595
+/-0.541
+/-0.811
+/-1.41
+/-0.336
+/-0.117 RPD%
Page 2 of 5 Page 26 of 44 SDG: 590180
QC Summary GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Rad Gamma Spec Rad Gas Flow 2305714 2305650 Batch Batch Bismuth-212 Bismuth-214 Cesium-134 Cesium-137 Cobalt-60 Europium-152 Europium-154 Lead-212 Lead-214 Potassium-40 Thallium-208 Strontium-90 Strontium-90 Parmname Units pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g Anlst Date Time KP1 KP1 08/26/22 08/26/22 15:05 15:05 QC
-0.0413 0.00615 0.0225
-0.0192 0.00986
-0.00507
-0.0153
-0.0345
-0.0388
-0.0931 0.0147 0.0120 2.06 NOM Sample 0.0141 Range N/A (75%-125%)
Qual U
U U
U U
U U
U U
U U
U QC1205169137 590180011 QC1205169138 QC1205169136 REC%
116 1.78 DUP LCS MB 590180 Workorder:
U
+/-0.0237
+/-0.114
+/-0.282
+/-0.0488
+/-0.0226
+/-0.0223
+/-0.0258
+/-0.0487
+/-0.0548
+/-0.0342
+/-0.0422
+/-0.283
+/-0.0389
+/-0.0202
+/-0.0955 Uncert:
Uncert:
Uncert:
Uncert:
Uncert:
Uncert:
Uncert:
Uncert:
Uncert:
Uncert:
Uncert:
Uncert:
Uncert:
Uncert:
TPU:
TPU:
TPU:
TPU:
TPU:
TPU:
TPU:
TPU:
TPU:
TPU:
TPU:
TPU:
TPU:
TPU:
+/-0.0239
+/-0.117
+/-0.283
+/-0.0489
+/-0.0248
+/-0.0239
+/-0.0262
+/-0.0487
+/-0.0552
+/-0.0376
+/-0.0458
+/-0.287
+/-0.0389
+/-0.0203
+/-0.380 0
RPD%
Page 3 of 5 Page 27 of 44 SDG: 590180
QC Summary GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Rad Gas Flow Rad Liquid Scintillation 2305650 2307619 Batch Batch Strontium-90 Nickel-63 Nickel-63 Nickel-63 Parmname Units pCi/g pCi/g pCi/g pCi/g Anlst Date Time KP1 TXJ1 TXJ1 TXJ1 08/26/22 08/30/22 08/30/22 08/30/22 15:05 09:52 10:08 09:36 QC 0.0124 4.10 254 1.64 NOM Sample
-0.134 Range N/A (75%-125%)
Qual U
U U
QC1205173125 590180001 QC1205173126 QC1205173124 The Qualifiers in this report are defined as follows:
REC%
102 249 DUP LCS MB 590180 Workorder:
BD FA H
J J
K L
M M
N/A N1 ND NJ Q
R U
UI UJ Analyte is a Tracer compound Result is less than value reported Result is greater than value reported Results are either below the MDC or tracer recovery is low Failed analysis.
Analytical holding time was exceeded See case narrative for an explanation Value is estimated Analyte present. Reported value may be biased high. Actual value is expected to be lower.
Analyte present. Reported value may be biased low. Actual value is expected to be higher.
M if above MDC and less than LLD REMP Result > MDC/CL and < RDL RPD or %Recovery limits do not apply.
See case narrative Analyte concentration is not detected above the detection limit Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier One or more quality control criteria have not been met. Refer to the applicable narrative or DER.
Sample results are rejected Analyte was analyzed for, but not detected above the MDL, MDA, MDC or LOD.
Gamma Spectroscopy--Uncertain identification Gamma Spectroscopy--Uncertain identification U
+/-5.28
+/-0.0226
+/-5.33
+/-10.6
+/-4.66 Uncert:
Uncert:
Uncert:
Uncert:
TPU:
TPU:
TPU:
TPU:
+/-5.28
+/-0.0227
+/-5.38
+/-48.1
+/-4.67 0
RPD%
TPU and Counting Uncertainty are calculated at the 95% confidence level (1.96-sigma).
Notes:
Page 4 of 5 Page 28 of 44 SDG: 590180
QC Summary GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Parmname Page 5 of 5 Units Anlst Date Time QC NOM Sample Range Qual REC%
590180 Workorder:
UL X
Y
^
h Not considered detected. The associated number is the reported concentration, which may be inaccurate due to a low bias.
Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Other specific qualifiers were required to properly define the results. Consult case narrative.
RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL. Qualifier Not Applicable for Radiochemistry.
Preparation or preservation holding time was exceeded N/A indicates that spike recovery limits do not apply when sample concentration exceeds spike conc. by a factor of 4 or more or %RPD not applicable.
- Indicates analyte is a surrogate/tracer compound.
^ The Relative Percent Difference (RPD) obtained from the sample duplicate (DUP) is evaluated against the acceptence criteria when the sample is greater than five times (5X) the contract required detection limit (RL). In cases where either the sample or duplicate value is less than 5X the RL, a control limit of +/- the RL is used to evaluate the DUP result.
For PS, PSD, and SDILT results, the values listed are the measured amounts, not final concentrations.
Where the analytical method has been performed under NELAP certification, the analysis has met all of the requirements of the NELAC standard unless qualified on the QC Summary.
RPD%
Page 29 of 44 SDG: 590180
Page 30 of 44 SDG: 590180 An EmffgySok1lions ConiP$ny Sample ID Matrix Ll-12102A-FIGS-202-SS SOIL Ll-12102A-FIGS-203-SS SOIL L l-12102A-FIGS-204-SS SOIL Ll-!2102A-FIGS-205-SS SOIL Ll-l2102A-QIGS-205-SS SOIL L 1-12102A-FIGS-206-SS SOIL Laboratory:
GEL Laboratories, LLC 2040 Savage Road Charleston, SC 29407 R{j7;);~~d f: /Zi'c kfti Relinquished by:
ZS-WM-131 Revision 0 Information Use - Chai11_-of-Custody Fonn 5f10;,*~
Sample Type Sample Container Sample Date Sample Analysis Type Preservative Remarks Vol Unit Type Qty Time SOIL 850.38 grams NIA l
07111/2022 1015 Gamma Spec NIA See comments SOIL 850.38 grams NIA 1
07/11/2022 1028 Gamma.Spec NIA See comments SOIL 850.38 grams NIA l
07111/2022 1035 Gamma.Spec NIA See comments SOIL 850.38 grams NIA I
07/ll/2022 1043 Gamma.Spec NIA See comments SOIL 850.38 grams N/A 1
07lll/2022 1043 Gamma.Spec NIA See comments SOIL 850.38 grams NIA I
07lll/2022 1050 Gamma Spec NIA See comments Date Submitted To Lab:
Ship Container No.:
Cooler Temperature:
Airbill Number:
07/20/202i NA NA 777'-I 3172 f lflb Date (mm/dd/yyyy):
Time:
Received by:
Date: (mm/dd/yyyy):
Time:
0 7 fl-o I JOZ2v ll OD fr0J fx 01 /10/J()JL-
//Oo Date (ihm/ddlfyyy):
Time:
Received ~:,I'
~
Date: (mfu/dd/yyyy):
Time:
.//fl;,-A
'()1)-,.;
7/2z/2z 90-f" Comments: Gamma Spec includes Cs137, Cs134, Co60 K-40, Bi-211/212/214, Pb-212/214, Ac-228, Tl-/oa as per June 23, 2021 e-mail and follow-up phone calls 1
of 1
Page 31 of 44 SDG: 590180 Sample ID Matrix Ll-12102A-FIGS-201-SS SOIL Ll-12102A-FIGS-20 I-SB SOIL Laboratory:
GEL Laboratories, LLC 2040 Savage Road Charleston, SC 29407 Re74;;~x;:rJ £ /?/ch rt Relinquished by:
ZS-WM-131 Revision 0 Information Use - Chain-of-Custody Form 5t101:J1-Sample Type Sample Container Sample Date Sample Analysis Type Preservative Remarks Vol Unit Type Qty Time SOIL 850.53 grams NIA l
07102/2022 0802 Gamma Spec N/A See comments SOIL 850.53 grams NIA I
07102/2022 0830 Gamma Spec N/A See comments Date Submitted To Lab:
Ship Container No.:
Cooler Temperature:
Airbill Number:
0 7 /Jo /20-zz, NA NA
'77711-3172- [1/rJp Date (mmldd/yyyy):
Time:
Received by:
Date: (mm/dd/yyyy):
Time:
()7/20/207-i II oo F(c! £Y:
07 /;c;/202,
//00 Dat! (mm/~d/yyyy):
Time:
Rece#?L D;t~;z Time:
<;(JS Comments: Gamma Spec includes Cs137, Cs134, Co60 K-40, Bi-211/212/214, Pb-212/214, Ac-228, Tl-208 as per June 23, 2021 e-mail and follow-up phone calls 1
of 1
-~ --
Page 32 of 44 SDG: 590180 Sample ID Matrix Ll-1220IE-FIGS-201-SS SOIL L 1-1220 I E-FIGS-202-SS SOIL Ll-12201E-QIGS-202-SS SOIL Laboratory:
GEL Laboratories, LLC 2040 Savage Road Charleston, SC 29407 R~T;h:~d f_f1/ikvrl Relinquished by: - Chain-of-Custody Fonn Sample Type Sample Container Sample Date Sample Vol Unit Type Qty Time SOIL 850.29 grams NIA l
0710612022 0936 SOIL 850.29 grams NIA I
07/06/2022 0940 SOIL 850.29 grams NIA l
07/06/2022 0940
,;g, 031-.
Analysis Type Preservative Gamma Spee NIA Gamma Spec NIA Gamma Spec NIA ZS-WM-131 Revision 0 Information Use Remarks See comments See comments See comments Date Submitted To Lab:
Ship Container No.:
Cooler Temperature:
Airbill Number:
0 7 /JO/:ZO 22-NA NA 777¥ 3!72-ll/3{:;
Date (mm/dd/yyyy):
Time:
Received bv:
Date: (rnm/dd/yyyy):
Time:
07 /J(l/JOJ //0()
[r,J fy 01/20/20J..2-
//00 Datef(mm/dMyyyy):
Time:
Received;;~~~
Date: (mmfdd/yy))Y):
Time:
7/22/22..,
9G2S Comments: Gamma Spec includes Cs137, Cs134, Co60 K-40, Bi-211/212/214, Pb-212/214, Ac-228, Tl-20!f'as per June 23, 2021 e-mail and follow-up phone calls 1
of 1
Page 33 of 44 SDG: 590180 Sample JD Matrix Ll-12201D-FIGS-301-SS SOIL Ll-1220 I D-FIGS-302-SS SOIL Ll-l2201D-FIGS-303-SS SOIL Ll-12201D-QIGS-303-SS SOIL Laboratory:
GEL Laboratories, LLC 2040 Savage Road Charleston, SC 29407 Relinquished by:
f?/cAard r,-R/ckeri Relinquished by:
ZS-WM-131 Revision 0 Information Use - Chain-of-Custody Form
~' (J3i.,
Sample Type Sample Container Sample Date Sample Analysis Type Preservative Remarks Vol Unit Type Qty Time SOJL 850.51 grams NIA l
07/06/2022 0920 Gamma Spec NIA See comments SOIL 850.51 grams NIA I
07/06/2022 0922 Gamma Spec NIA See comments SOIL 850.51 grams NIA I
07/06/2022 0925 Gamma Spec NIA See comments SOIL 850.51 grams NIA l
07/06/2022 0925 Gamma Spec NIA See comments Date Submitted To Lab:
Ship Container No.:
Cooler Temperature:
Airbill Number:
07 /20/,2o;z2, NA NA 7771/ "3172 11/Sb Date (mm/dd/yyyy):
Time:
Received by:
Date: {mm/dd/yyyy):
Time:
()J /20/202-i
// oO (cJ fx
() 7/20/1022
/!O()
Date(mm!d6/yyyy):
Time:
Receiv~
Date: (~~dd!A,yy):
Time:
7/zJ;/22.
'?OS
!IJ'4 tfd/94'(
Comments: Gamma Spec includes Cs 137, Cs134, Co60 K-40, Bi-211/212/214, Pb-212/214, Ac-228, Tl-2~8 as per June 23, 2021 e-mail and follow-up phone calls 1
of 1
-- -~
Page 34 of 44 SDG: 590180 Sample ID Matrix L l-l 2201C-FIGS-202-SS SOIL L 1-12201 C-FIGS-203-SS SOIL Ll-12201C-FJGS-204-SS SOIL Ll-12201C-FIGS-205-SS SOIL Laboratory:
GEL Laboratories, LLC 2040 Savage Road Charleston, SC 29407 Re~~uf;;;;;td f-rf/vkvr f Relinquished by: - Chain-of-Custody Form Sample Type Sample Container Sample Date Sample Vol Unit Type Qty Time SOIL 850.38 grams NIA 1
0711212022 1340 SOIL 850.38 grams NIA 1
07112/2022 1348 SOIL 850.38 grams NIA I
0711212022 1352 SOIL 850.38 grams NIA l
0711212022 1356 st,o,~
Analysis Type Preservative Gamma Spec NIA Gamma Spec NIA Gamma Spec NIA Gamma Spec NIA ZS-WM-131 Revision 0 Information Use Remarks See comments See comments See comments See comments Date Submitted To Lab:
Ship Container No.:
Cooler Temperature:
Airbill Number:
07 /20/ 207 NA NA 777~ 3112 !'18b Date (mmldd/yyyy):
Time:
Received by:
Date: (mm/ddlyyyy):
Time:
07 I 2 0 )20 2-Z..
II ()CJ reJe:1 07'10/2022-
!/00 Date (mm/dd/fyyy):
Time:
Recei~,&
Date: (m6vdd/5-yyy):
Time:
ilA
'{r(9IN' 7/z.2./zL 9G..5' Comments: Gamma Spec includes Cs137, Cs 134, Co60 K-40, Bi-211/212/214, Pb-212/214, Ac-228, Tl-268 as per June 23, 2021 e-mail and follow-up phone calls l
of 1
-- ~-
Page 35 of 44 SDG: 590180 An EnergyS:l!utiorrs Comp$:ny Sample ID Matrix Ll-1220I C-FIGS-201-SS SOIL L1-12201C-QIGS-201-SS SOIL L 1-12201C-FIGS-201-SB SOIL Laboratory:
GEL Laboratories, LLC 2040 Savage Road Charleston, SC 29407 R~}:h~b;J k K/rl<irf Relinquished by:
ZS-WM-131 Revision 0 Information Use - Chain-of-Custody Form S:-&<()'?V Sample Type Sample Container Sample Date Sample Analysis Type Preservative Remarks Vol Unit Type Qty Time SOIL 850.88 grams NIA I
06115/2022 0940 Gamma Spec NIA See comments SOIL 850.88 grams NIA I
06/1512022 0940 Gamma Spec NIA See comments SOIL 850.88 grams NIA I
06/15/2022 0950 Gamma Spec NIA See comments Date Submitted To Lab:
Ship Container No.:
Cooler Temperature:
Airbill Number:
01 / 2 0 / 2 o ;L2--
NA NA 777 t/3f 7~_,Jlf 8 b Date (mm/dd/yyyy):
Time:
Received by:
Date: (mm/dd/yyyy):
Time:
01/20/201- !loo (JU
()7 / ;.0/1022-lloo Date (1nm/dd/yyyy):
Time:
Rec~~~
Date: (mm/dd3/yyyy):
Time:
-z /zzlz:2 q~(:15
.{o l
Comments: Gamma Spec includes Cs137, Cs134, Co60 K-40, Bi-211/212/214, Pb-212/214, Ac-228, Tl- 08 as per June 23, 2021 e-mail and follow-up phone calls 1
of 1
Page 36 of 44 SDG: 590180 Sample ID Matrix Ll-12103A-FIGS-301-SS SOIL LI-I 2103A-FIGS-30 I-SB SOIL Laboratory:
GEL Laboratories, LLC 2040 Savage Road Charleston, SC 29407 Ret2:l~h~:rd f fihkcrt Relinquished by: - Chain-of-Custody Form Sample Type Sample Container Sample Date Sample Vol Unit Type Qty Time SOIL 850.01 grams NIA I
06/27/2022 0905 SOIL 850.01 grams NIA 1
06/27/2022 0908 Analysis Type Gamma Spec Gamma Spec ZS-WM-131 Revision 0 Information Use S8'1o}t-Preservative Remarks NIA See comments NIA See comments Date Submitted To Lab:
Ship Container No.:
Cooler Temperature:
Airbill Number:
7/7-o/Jol-~
NA NA 777lf J/72 JL/8/;
Date (mm/dd/yyyy):
Time:
Received by:
Date: (mm/dd/yyyy):
Time:
o 7 rzo/J(Jti fl OD feJ/3-x 0 7 /20/)() 7-:2-
//60 Date (mm/ddYyyyy):
Time:
Received by:
Date: (mm1dd/yy#y):
Time:
di£-
7,/22/2..L q(J.r Comments: Gamma Spec includes Cs137, Cs134, Co60 K-40, Bi-211/212/214, Pb-212/214, Ac-228, Tl-208 as per June 23, 2021 e-mail and follow-up phone calls 1
of 1
-~ --
Page 37 of 44 SDG: 590180 An Eni.'1'.gy,S,w.Akms Coinpany Sample ID Matrix L 1-12103A-FIGS-302-SS SOIL L 1-12103A-FIGS-303-SS SOIL Ll-12103A-FIGS-304-SS SOIL Ll-12103A-FIGS-305-SS SOIL Ll-12103A-FIGS-306-SS SOIL Ll-12103A-FIGS-307-SS SOIL Ll-12103A-FIGS-308-SS SOIL Ll-I2103A-QIGS-308-SS SOIL Laboratory:
GEL Laboratories, LLC 2040 Savage Road Charleston, SC 29407 Ri7~J;~;) f/ )?,\kcrt Relinquished by:
ZS-WM-131 Revision 0 Information Use - Chain-of-Custody Form S~1 o,");-
Sample Type Sample Container Sample Date Sample Analysis Type Preservative Remarks Vol Unit Type Qty Time SOIL 850.25 grams NIA 1
07/11/2022 0935 Gamma Spec NIA See comments SOIL 850.25 grams NIA 1
07/1112022 0937 Gamma Spec NIA See comments SOIL 850.25 grams NIA I
0711112022 0944 Gamma Spec NIA See comments SOIL 850.25 grams NIA I
07/11/2022 0950 Gamma Spec NIA See comments SOIL 850.25 grams NIA I
07/11/2022 0958 Gamma Spec NIA See comments SOIL 850.25 grams NIA l
07/11/2022 1005 Gamma Spec NIA See comments SOIL 850.25 grams NIA 1
0711112022 1012 Gamma Spec NIA See comments SOIL 850.25 grams N/A 1
07/11/2022 1012 Gamma Spec NIA See comments Date Submitted To Lab:
Ship Container No.:
Cooler Temperature:
Airbill Number:
07 /10/:207-~
NA NA 7771.f 3[?2 !L/8t Date (mm/ddlyyyy):
Time:
Received by:
Date: (mm/dd/yyyy):
Time:
07 /1-0/J(/F~
Frd£x I
I/OJ 07/Jo/Jo?J-I! tJO Date (rhm/dd/$-yyy):
Time:
Rece#L Date: (mmtlld/yyyy):
Time:
7/22/22.
Cf(J-f' Comments: Gamma Spec includes Cs137, Cs134, Co60 K-40, Bi-211/212/214, Pb-212/214, Ac-228, Tl-208 as per June 23, 2021 e-mail and follow-up phone calls 1
of 1
Page 38 of 44 SDG: 590180 Survey#: 2.ot1. -ooc::t7
==
Description:==
SA!!l~.t'.S Ft,a.._ $/J)ftfllf%(e: 7 !rf/2.Z...
Time:67l./S-Unit:_MLMLDG: /II/ft. ELEV: ~z' Surveyor Name(s): (Print) 0£/.J,,./ &£/<i'?G'.$
(Sign) /'d-- ~
SOLVTIONS,...
RWP: ZoZZ. ooo 1 Rad Posting:
JV/n
!Air Sample taken: yes.s!no Dosimetry Placement: !l!l Chest Head All dose rates in mrem/hr unless otherwise noted Thigh Other o F6:t,} so;l... 8/J.'5 Instrument Model Serial#
.SJ:b~~1tll6 Si.JR.vet-IN
( lJ lo r:,14llcui/ &--r ~llf-m-J 2.:.9~.~"
_az,,_L(J_Z)_~o l, t.
$f,l~l.£. ~.s ___ /1"1Jil'f.::L_/J-~~~-~-~,_',.J_~ ____ S_t1&_v11.._-y __ /(~ s v m.
Ji,~"'
~:,1 it'! l (1(-
IL/-~
2 7 1 ' '9 <
/HJ.£
/J:.S.
f'olLat,,,t<;.
. -~--"--~--*---*-*-~----**~-*----------*-.. --*-*~--*-*~*
All Smears and/or Large Area Swipes
<1000 dpm/100cm 2 (unless noted below) Massi inns All D1R£GtJ rdilS /e.. £ 0 1"u.m.s
~ BKL,o
,;1::.
io -"lo <..e_-
~-y a
~-y a
Letter
~-y 7
/110 fl- _______ 8 -. I~.. 'Df !:""_/ o.. -
/
fol,.(..
O.t$_~ __ Sm.£A.@..:S ___. <
/$". 1 tlf---
--** --~***-*--*--- ~-----*----~*-*---***---*------**--**** -*
_v C0<1 tVT.CA l!)tl/
A-.50.so.
.v
- .,I I/
- ---------~----*--***-----***-***-~ --------***-** - **-*----
/4
~~G.L_dU~ ~ /80 e:..t:.p~pa.oG£. Atc.c~.
V
/
_Dc.sc.. IJ..~T£>
/
C..e-lJLJ A-c. "J (1,-v
/+LL.. --,$01 _(.. ___ B,+6S frtl/QSJJ lff l~&>
/
V C.oNIA,,.., R:,S 0-ol mLjt111-DRPs detected: Yes 151/'Jo ON/A Purpose of Survey:
Comments:
---*---- --------*--*--*----------~-------..
"'-----------------------~--- -- ---**-- -. -*. --------***------
RWP Decon Recommended
&.5_ l<&re.s e.. -3o_ c.,-. ~_g___L m £"T"£ a-..
~ t,... e I f'i1, A-LI3/4 n-D Routine Shielding Recommended I
D lnvestigational Release Recommended D Release
~
None
..Slflfq>&'tvJ ff' R'W<2)<002-0
~ Other (specify)
Other (specify)
~ff A/J pU;,vj"
= Rad boundary
- /#
~
= Contact/ 30cm dose rates
~---~----*-*-
= Gamma dose rate
= Smear location 8 -Large area swipe Peer Check (Signature):
w:rv:./
RPS Approval (Signature): &~\,_./?
/
'__Vj
Page 39 of 44 SDG: 590180 SAMPLE RECEIPT & REVIEW FORM Client:
,=t\.ual c.
SDG/AR/COC/Work Order:
c;s,o}'Z Received Bv: STACY 8MNE DateReceived:JULV 22 2ti22 Cirdc Applkahlc:
FedEx~ress FedEx Ground UPS Field Services Courier Other Carrier and Tracking Number 777'-I :H'12 I 1486 Suspected Hazard Information a'.l 0
- If Net Counts> lOOcpm on samples not marked "radioactive", contact the Radiation Safety Group for further inve.stig.ttion.
- ,.. z Hazard Class Shipped
UN#:
A)Shiooed as a DOT Hazardous?
/!4 If UN29 I 0. Is lhe Radioaclive Shipment Survey Complianl? Yes_ No_
B) Did the client designale the samples are to be COC notation or mdioattive stickers on containeffi equal client designation.
received as radioactive'!
C) Did the RSO classify the samples as Maximum Net Counts Observed* (Observed Counts -Area Background Counts): -'lt_CPM / mR/Hr Classified as: Rad I Rad 2 Rad3 radioactive?
/
COC notation or ha1.ard labels on containers equal clienl designation.
D) Did lhc client designate samples are hazardous?
,,. MD or E is yes. select Hazards below.
El Did the RSO identifv possible hazards?
PCB's Flammable Foreign Soil RCRA Asbeslos Beryllium Other.
Sample Receipt Criteria
~ < "
Comments/Qualifiers (Required for Non-Confonning Items)
- .. z z Shipping containers received intact and Circle Applicable
Seals broken Dmnuged container Leaking container Other (describe) 1 scaled?
Chain of custody documents included Circle Applicable:
Client con1ac1cd and provided COC COC crca1cd upon receipt 2 with shipment?
Preservation MetlK,<l: Wet kc Ice Packs Dry ice None Other:
3 Samples requiring cold preservation
- all temperatures are recorded in Celsius TEMP: :Z.1 within (0 < 6 deg. CJ?*
Daily check performed and passed on IR Temperature Device Serial #:
T -..-... 7 7 4 temperature gun?
Sccondm)' Temperature Device Serial# (If Applicable):
Circle Af'lplicablc:
Seals hrokcn D,1ma!,.1Cd container Leaking container Other (describe) 5 Sample containers intact and sealed?
Samples requiring chemical preservation Sample lD's and Containers Aflcctcd:
6 at proper pH?
If Prcscrv-,llion added, Lot#:
If Yes, are Encores or Soil Kits present for solids? Yes No NA (If yes. take lo VOA Freezer)
Do any samples require Volatile Do liquid VOA vials contain acid preservation? Yes No NA_(lfonknown. select No) 7 JJ,re liquid VOA vials free ofheadspace? Yes_ No_ NA_
Analysis?
.,,,. Sample lD's and containers affcclcd:
!D's and tests affecled:
8 Samples received within holding lime?
Sample !D's on COC match !D's on fD's and container:s affected:
9 bottles?
Date & time on COC match date & time Circle Applicable: No dales on containers No times on containers COC missing info Other (describe) 10 on bottles?
Number of containers received match Circle Applicable: No container count on COC Other (describe) 11 number indicated on COC?
12 Are sample containers identifiable as
/
GEL orovided bv use of GEL labels?
COC form is properly signed in Circle Applicable:
Not relinquished Other (describe) 13 relinquished/received sections?
Comments (Use Continuation Form if needed):
PM (or PMA) review: lniti,tls VVlK Date I/ 'J, 'l J 1/l Page J_ of l_
I I
GL-CHL-SR-001 Rev 7
State Certification Alabama Alaska Alaska Drinking Water Arkansas CLIA California Colorado Connecticut DoD ELAP/ ISO17025 A2LA Florida NELAP Foreign Soils Permit Georgia Georgia SDWA Hawaii Idaho Illinois NELAP Indiana Kansas NELAP Kentucky SDWA Kentucky Wastewater Louisiana Drinking Water Louisiana NELAP Maine Maryland Massachusetts Massachusetts PFAS Approv Michigan Mississippi Nebraska Nevada New Hampshire NELAP New Jersey NELAP New Mexico New York NELAP North Carolina North Carolina SDWA North Dakota Oklahoma Pennsylvania NELAP Puerto Rico S. Carolina Radiochem Sanitation Districts of L South Carolina Chemistry Tennessee Texas NELAP Utah NELAP Vermont Virginia NELAP Washington 42200 17018 SC00012 880651 42D0904046 2940 SC00012 PH0169 2567.01 E87156 P3301500283, P3301500253 SC00012 967 SC00012 SC00012 200029 CSC01 E10332 90129 90129 LA024 03046 (AI33904) 2019020 270 MSC012 Letter 9976 SC00012 NEOS2613 SC0001220233 2054 SC002 SC00012 11501 233 45709 R158 2019165 6800485 SC00012 10120002 9255651 10120001 TN 02934 T1047042352220 SC00012202136 VT87156 460202 C780 List of current GEL Certifications as of 30 August 2022 Page 40 of 44 SDG: 590180
Radiochemistry Technical Case Narrative Zion Solutions SDG #: 590180 Product: Dry Weight Preparation Method: Dry Soil Prep Preparation Procedure: GL-RAD-A-021 REV# 24 Preparation Batch: 2305626 The following samples were analyzed using the above methods and analytical procedure(s).
GEL Sample ID# Client Sample Identification 590180001 L1-12201C-FIGS-201-SS 590180002 L1-12201C-FIGS-201-SB 590180003 L1-12201C-FIGS-202-SS 590180004 L1-12201D-FIGS-303-SS 590180005 L1-12201E-FIGS-202-SS 590180006 L1-12102A-FIGS-201-SB 590180007 L1-12102A-FIGS-202-SS 590180008 L1-12102A-FIGS-206-SS 590180009 L1-12103A-FIGS-301-SS 590180010 L1-12103A-FIGS-301-SB 590180011 L1-12103A-FIGS-302-SS The samples in this SDG were analyzed on an "as received" basis.
Data Summary:
All sample data provided in this report met the acceptance criteria specified in the analytical methods and procedures for initial calibration, continuing calibration, instrument controls and process controls where applicable, with the following exceptions.
Miscellaneous Information Additional Comments These samples are relogs. The data for this batch was transferred from batches 2293364 and 2293365.
Product: Gammaspec, Gamma, Solid (Requested List)
Analytical Method: DOE HASL 300, 4.5.2.3/Ga-01-R Analytical Procedure: GL-RAD-A-013 REV# 27 Analytical Batch: 2305714 Preparation Method: Dry Soil Prep Preparation Procedure: GL-RAD-A-021 REV# 24 Preparation Batch: 2305626 Page 41 of 44 SDG: 590180
The following samples were analyzed using the above methods and analytical procedure(s).
GEL Sample ID# Client Sample Identification 590180001 L1-12201C-FIGS-201-SS 590180002 L1-12201C-FIGS-201-SB 590180003 L1-12201C-FIGS-202-SS 590180004 L1-12201D-FIGS-303-SS 590180005 L1-12201E-FIGS-202-SS 590180006 L1-12102A-FIGS-201-SB 590180007 L1-12102A-FIGS-202-SS 590180008 L1-12102A-FIGS-206-SS 590180009 L1-12103A-FIGS-301-SS 590180010 L1-12103A-FIGS-301-SB 590180011 L1-12103A-FIGS-302-SS 1205169262 Method Blank (MB) 1205169263 590180001(L1-12201C-FIGS-201-SS) Sample Duplicate (DUP) 1205169264 Laboratory Control Sample (LCS)
The samples in this SDG were analyzed on a "dry weight" basis.
Data Summary:
There are no exceptions, anomalies or deviations from the specified methods. All sample data provided in this report met the acceptance criteria specified in the analytical methods and procedures for initial calibration, continuing calibration, instrument controls and process controls where applicable.
Qualifier Information Qualifier Reason Analyte Sample Client Sample UI Results are considered a false positive due to high peak-width.
Bismuth-212 590180007 L1-12102A-FIGS-202-SS UI Results are considered a false positive due to low abundance.
Bismuth-211 590180001 L1-12201C-FIGS-201-SS Bismuth-211 590180002 L1-12201C-FIGS-201-SB Bismuth-211 590180003 L1-12201C-FIGS-202-SS Bismuth-211 590180005 L1-12201E-FIGS-202-SS Bismuth-211 590180007 L1-12102A-FIGS-202-SS Bismuth-211 590180008 L1-12102A-FIGS-206-SS Bismuth-211 590180010 L1-12103A-FIGS-301-SB Bismuth-211 1205169263 L1-12201C-FIGS-201-SS(590180001DUP)
Page 42 of 44 SDG: 590180
Cesium-134 590180011 L1-12103A-FIGS-302-SS Product: GFPC, Sr90, Solid Analytical Method: EPA 905.0 Modified/DOE RP501 Rev. 1 Modified Analytical Procedure: GL-RAD-A-004 REV# 22 Analytical Batch: 2305650 Preparation Method: Dry Soil Prep Preparation Procedure: GL-RAD-A-021 REV# 24 Preparation Batch: 2305626 The following samples were analyzed using the above methods and analytical procedure(s).
GEL Sample ID# Client Sample Identification 590180001 L1-12201C-FIGS-201-SS 590180002 L1-12201C-FIGS-201-SB 590180003 L1-12201C-FIGS-202-SS 590180004 L1-12201D-FIGS-303-SS 590180005 L1-12201E-FIGS-202-SS 590180006 L1-12102A-FIGS-201-SB 590180007 L1-12102A-FIGS-202-SS 590180008 L1-12102A-FIGS-206-SS 590180009 L1-12103A-FIGS-301-SS 590180010 L1-12103A-FIGS-301-SB 590180011 L1-12103A-FIGS-302-SS 1205169136 Method Blank (MB) 1205169137 590180011(L1-12103A-FIGS-302-SS) Sample Duplicate (DUP) 1205169138 Laboratory Control Sample (LCS)
The samples in this SDG were analyzed on a "dry weight" basis.
Data Summary:
All sample data provided in this report met the acceptance criteria specified in the analytical methods and procedures for initial calibration, continuing calibration, instrument controls and process controls where applicable, with the following exceptions.
Preparation Information Homogenous Matrix Samples were non-homogenous matrix. samples are grainy and sandy Product: Liquid Scint Ni63, Solid Analytical Method: DOE RESL Ni-1, Modified Analytical Procedure: GL-RAD-A-022 REV# 19 Analytical Batch: 2307619 Page 43 of 44 SDG: 590180
Preparation Method: Dry Soil Prep Preparation Procedure: GL-RAD-A-021 REV# 24 Preparation Batch: 2305626 The following samples were analyzed using the above methods and analytical procedure(s).
GEL Sample ID# Client Sample Identification 590180001 L1-12201C-FIGS-201-SS 590180002 L1-12201C-FIGS-201-SB 590180003 L1-12201C-FIGS-202-SS 590180004 L1-12201D-FIGS-303-SS 590180005 L1-12201E-FIGS-202-SS 590180006 L1-12102A-FIGS-201-SB 590180007 L1-12102A-FIGS-202-SS 590180008 L1-12102A-FIGS-206-SS 590180009 L1-12103A-FIGS-301-SS 590180010 L1-12103A-FIGS-301-SB 590180011 L1-12103A-FIGS-302-SS 1205173124 Method Blank (MB) 1205173125 590180001(L1-12201C-FIGS-201-SS) Sample Duplicate (DUP) 1205173126 Laboratory Control Sample (LCS)
The samples in this SDG were analyzed on a "dry weight" basis.
Data Summary:
There are no exceptions, anomalies or deviations from the specified methods. All sample data provided in this report met the acceptance criteria specified in the analytical methods and procedures for initial calibration, continuing calibration, instrument controls and process controls where applicable.
Certification Statement Where the analytical method has been performed under NELAP certification, the analysis has met all of the requirements of the NELAC standard unless otherwise noted in the analytical case narrative.
Page 44 of 44 SDG: 590180