RESRAD, Version 7.0 T1/2 Limit = 30 days 12/06/2014 13:09 Page 1 Summary : Zion Surface Soil 3,000 m^2 120614 File : C:\\RESRAD_FAMILY\\RESRAD\\7.0\\USERFILES\\ZION SURFACE SOIL DCGL.RAD Table of Contents Part I: Mixture Sums and Single Radionuclide Guidelines Dose Conversion Factor (and Related) Parameter Summary... 2 Site-Specific Parameter Summary.......................... 4 Summary of Pathway Selections............................ 8 Contaminated Zone and Total Dose Summary................. 9 Total Dose Components Time = 0.000E+00.................................... 10 Time = 1.000E+00.................................... 11 Time = 3.000E+00.................................... 12 Time = 1.000E+01.................................... 13 Time = 3.000E+01.................................... 14 Time = 1.000E+02.................................... 15 Time = 3.000E+02.................................... 16 Time = 1.000E+03.................................... 17 Dose/Source Ratios Summed Over All Pathways.............. 18 Single Radionuclide Soil Guidelines...................... 18 Dose Per Nuclide Summed Over All Pathways................ 19 Soil Concentration Per Nuclide........................... 19

RESRAD, Version 7.0 T1/2 Limit = 30 days 12/06/2014 13:09 Page 2 Summary : Zion Surface Soil 3,000 m^2 120614 File : C:\\RESRAD_FAMILY\\RESRAD\\7.0\\USERFILES\\ZION SURFACE SOIL DCGL.RAD Dose Conversion Factor (and Related) Parameter Summary Dose Library: Surface Soil DCGL Plus FGR 11 Current Base Parameter Menu Parameter Value# Case* Name HHHH A-1 DCF's for external ground radiation, (mrem/yr)/(pCi/g)

A-1 Ba-137m (Source: FGR 12) 3.606E+00 3.606E+00 DCF1( 1)

A-1 Co-60 (Source: FGR 12) 1.622E+01 1.622E+01 DCF1( 2)

A-1 Cs-134 (Source: FGR 12) 9.472E+00 9.472E+00 DCF1( 3)

A-1 Cs-137 (Source: FGR 12) 7.510E-04 7.510E-04 DCF1( 4)

A-1 Ni-63 (Source: FGR 12) 0.000E+00 0.000E+00 DCF1( 5)

A-1 Sr-90 (Source: FGR 12) 7.043E-04 7.043E-04 DCF1( 6)

A-1 Y-90 (Source: FGR 12) 2.391E-02 2.391E-02 DCF1( 7)

B-1 Dose conversion factors for inhalation, mrem/pCi:

B-1 Co-60 2.190E-04 2.190E-04 DCF2( 1)

B-1 Cs-134 4.620E-05 4.620E-05 DCF2( 2)

B-1 Cs-137+D 3.190E-05 3.190E-05 DCF2( 3)

B-1 Ni-63 6.290E-06 6.290E-06 DCF2( 4)

B-1 Sr-90+D 1.308E-03 1.300E-03 DCF2( 5)

D-1 Dose conversion factors for ingestion, mrem/pCi:

D-1 Co-60 2.690E-05 2.690E-05 DCF3( 1)

D-1 Cs-134 7.330E-05 7.330E-05 DCF3( 2)

D-1 Cs-137+D 5.000E-05 5.000E-05 DCF3( 3)

D-1 Ni-63 5.770E-07 5.770E-07 DCF3( 4)

D-1 Sr-90+D 1.528E-04 1.420E-04 DCF3( 5)

D-34 Food transfer factors:

D-34 Co-60, plant/soil concentration ratio, dimensionless 1.500E-01 8.000E-02 RTF( 1,1)

D-34 Co-60, beef/livestock-intake ratio, (pCi/kg)/(pCi/d) 5.800E-02 2.000E-02 RTF( 1,2)

D-34 Co-60, milk/livestock-intake ratio, (pCi/L)/(pCi/d) 2.000E-03 2.000E-03 RTF( 1,3)

D-34 D-34 Cs-134, plant/soil concentration ratio, dimensionless 7.800E-02 4.000E-02 RTF( 2,1)

D-34 Cs-134, beef/livestock-intake ratio, (pCi/kg)/(pCi/d) 6.500E-02 3.000E-02 RTF( 2,2)

D-34 Cs-134, milk/livestock-intake ratio, (pCi/L)/(pCi/d) 1.400E-02 8.000E-03 RTF( 2,3)

D-34 D-34 Cs-137+D, plant/soil concentration ratio, dimensionless 7.800E-02 4.000E-02 RTF( 3,1)

D-34 Cs-137+D, beef/livestock-intake ratio, (pCi/kg)/(pCi/d) 6.500E-02 3.000E-02 RTF( 3,2)

D-34 Cs-137+D, milk/livestock-intake ratio, (pCi/L)/(pCi/d) 1.400E-02 8.000E-03 RTF( 3,3)

D-34 D-34 Ni-63, plant/soil concentration ratio, dimensionless 9.200E-02 5.000E-02 RTF( 4,1)

D-34 Ni-63, beef/livestock-intake ratio, (pCi/kg)/(pCi/d) 5.000E-03 5.000E-03 RTF( 4,2)

D-34 Ni-63, milk/livestock-intake ratio, (pCi/L)/(pCi/d) 3.200E-02 2.000E-02 RTF( 4,3)

D-34 D-34 Sr-90+D, plant/soil concentration ratio, dimensionless 5.900E-01 3.000E-01 RTF( 5,1)

D-34 Sr-90+D, beef/livestock-intake ratio, (pCi/kg)/(pCi/d) 8.000E-03 8.000E-03 RTF( 5,2)

D-34 Sr-90+D, milk/livestock-intake ratio, (pCi/L)/(pCi/d) 2.700E-03 2.000E-03 RTF( 5,3)

D-5 Bioaccumulation factors, fresh water, L/kg:

D-5 Co-60, fish 3.000E+02 3.000E+02 BIOFAC( 1,1)

D-5 Co-60, crustacea and mollusks 2.000E+02 2.000E+02 BIOFAC( 1,2)

D-5 D-5 Cs-134, fish 2.000E+03 2.000E+03 BIOFAC( 2,1)

D-5 Cs-134, crustacea and mollusks 1.000E+02 1.000E+02 BIOFAC( 2,2)

RESRAD, Version 7.0 T1/2 Limit = 30 days 12/06/2014 13:09 Page 3 Summary : Zion Surface Soil 3,000 m^2 120614 File : C:\\RESRAD_FAMILY\\RESRAD\\7.0\\USERFILES\\ZION SURFACE SOIL DCGL.RAD Dose Conversion Factor (and Related) Parameter Summary (continued)

Dose Library: Surface Soil DCGL Plus FGR 11 Current Base Parameter Menu Parameter Value# Case* Name HHHH D-5 Cs-137+D, fish 2.000E+03 2.000E+03 BIOFAC( 3,1)

D-5 Cs-137+D, crustacea and mollusks 1.000E+02 1.000E+02 BIOFAC( 3,2)

D-5 D-5 Ni-63, fish 1.000E+02 1.000E+02 BIOFAC( 4,1)

D-5 Ni-63, crustacea and mollusks 1.000E+02 1.000E+02 BIOFAC( 4,2)

D-5 D-5 Sr-90+D, fish 6.000E+01 6.000E+01 BIOFAC( 5,1)

D-5 Sr-90+D, crustacea and mollusks 1.000E+02 1.000E+02 BIOFAC( 5,2)

  1. For DCF1(xxx) only, factors are for infinite depth & area. See ETFG table in Ground Pathway of Detailed Report.
  • Base Case means Default.Lib w/o Associate Nuclide contributions.

RESRAD, Version 7.0 T1/2 Limit = 30 days 12/06/2014 13:09 Page 4 Summary : Zion Surface Soil 3,000 m^2 120614 File : C:\\RESRAD_FAMILY\\RESRAD\\7.0\\USERFILES\\ZION SURFACE SOIL DCGL.RAD Site-Specific Parameter Summary User Used by RESRAD Parameter Menu Parameter Input Default (If different from user input) Name HHHHH R011 Area of contaminated zone (m**2) 3.000E+03 1.000E+04 --- AREA R011 Thickness of contaminated zone (m) 1.500E-01 2.000E+00 --- THICK0 R011 Fraction of contamination that is submerged 0.000E+00 0.000E+00 --- SUBMFRACT R011 Length parallel to aquifer flow (m) 6.180E+01 1.000E+02 --- LCZPAQ R011 Basic radiation dose limit (mrem/yr) 2.500E+01 3.000E+01 --- BRDL R011 Time since placement of material (yr) 0.000E+00 0.000E+00 --- TI R011 Times for calculations (yr) 1.000E+00 1.000E+00 --- T( 2)

R011 Times for calculations (yr) 3.000E+00 3.000E+00 --- T( 3)

R011 Times for calculations (yr) 1.000E+01 1.000E+01 --- T( 4)

R011 Times for calculations (yr) 3.000E+01 3.000E+01 --- T( 5)

R011 Times for calculations (yr) 1.000E+02 1.000E+02 --- T( 6)

R011 Times for calculations (yr) 3.000E+02 3.000E+02 --- T( 7)

R011 Times for calculations (yr) 1.000E+03 1.000E+03 --- T( 8)

R011 Times for calculations (yr) not used 0.000E+00 --- T( 9)

R011 Times for calculations (yr) not used 0.000E+00 --- T(10)

R012 Initial principal radionuclide (pCi/g): Co-60 1.000E+00 0.000E+00 --- S1(1)

R012 Initial principal radionuclide (pCi/g): Cs-134 1.000E+00 0.000E+00 --- S1(2)

R012 Initial principal radionuclide (pCi/g): Cs-137 1.000E+00 0.000E+00 --- S1(3)

R012 Initial principal radionuclide (pCi/g): Ni-63 1.000E+00 0.000E+00 --- S1(4)

R012 Initial principal radionuclide (pCi/g): Sr-90 1.000E+00 0.000E+00 --- S1(5)

R012 Concentration in groundwater (pCi/L): Co-60 not used 0.000E+00 --- W1( 1)

R012 Concentration in groundwater (pCi/L): Cs-134 not used 0.000E+00 --- W1( 2)

R012 Concentration in groundwater (pCi/L): Cs-137 not used 0.000E+00 --- W1( 3)

R012 Concentration in groundwater (pCi/L): Ni-63 not used 0.000E+00 --- W1( 4)

R012 Concentration in groundwater (pCi/L): Sr-90 not used 0.000E+00 --- W1( 5)

R013 Cover depth (m) 0.000E+00 0.000E+00 --- COVER0 R013 Density of cover material (g/cm**3) not used 1.500E+00 --- DENSCV R013 Cover depth erosion rate (m/yr) not used 1.000E-03 --- VCV R013 Density of contaminated zone (g/cm**3) 1.800E+00 1.500E+00 --- DENSCZ R013 Contaminated zone erosion rate (m/yr) 1.500E-03 1.000E-03 --- VCZ R013 Contaminated zone total porosity 3.500E-01 4.000E-01 --- TPCZ R013 Contaminated zone field capacity 6.600E-02 2.000E-01 --- FCCZ R013 Contaminated zone hydraulic conductivity (m/yr) 2.880E+03 1.000E+01 --- HCCZ R013 Contaminated zone b parameter 9.700E-01 5.300E+00 --- BCZ R013 Average annual wind speed (m/sec) 4.200E+00 2.000E+00 --- WIND R013 Humidity in air (g/m**3) not used 8.000E+00 --- HUMID R013 Evapotranspiration coefficient 6.250E-01 5.000E-01 --- EVAPTR R013 Precipitation (m/yr) 8.300E-01 1.000E+00 --- PRECIP R013 Irrigation (m/yr) 1.900E-01 2.000E-01 --- RI R013 Irrigation mode overhead overhead --- IDITCH R013 Runoff coefficient 2.000E-01 2.000E-01 --- RUNOFF R013 Watershed area for nearby stream or pond (m**2) 1.000E+06 1.000E+06 --- WAREA R013 Accuracy for water/soil computations 1.000E-03 1.000E-03 --- EPS R014 Density of saturated zone (g/cm**3) 1.800E+00 1.500E+00 --- DENSAQ R014 Saturated zone total porosity 3.500E-01 4.000E-01 --- TPSZ R014 Saturated zone effective porosity 2.900E-01 2.000E-01 --- EPSZ R014 Saturated zone field capacity 6.600E-02 2.000E-01 --- FCSZ

RESRAD, Version 7.0 T1/2 Limit = 30 days 12/06/2014 13:09 Page 5 Summary : Zion Surface Soil 3,000 m^2 120614 File : C:\\RESRAD_FAMILY\\RESRAD\\7.0\\USERFILES\\ZION SURFACE SOIL DCGL.RAD Site-Specific Parameter Summary (continued)

User Used by RESRAD Parameter Menu Parameter Input Default (If different from user input) Name HHHHH R014 Saturated zone hydraulic conductivity (m/yr) 2.880E+03 1.000E+02 --- HCSZ R014 Saturated zone hydraulic gradient 3.900E-03 2.000E-02 --- HGWT R014 Saturated zone b parameter not used 5.300E+00 --- BSZ R014 Water table drop rate (m/yr) 0.000E+00 1.000E-03 --- VWT R014 Well pump intake depth (m below water table) 3.300E+00 1.000E+01 --- DWIBWT R014 Model: Nondispersion (ND) or Mass-Balance (MB) ND ND --- MODEL R014 Well pumping rate (m**3/yr) 2.250E+03 2.500E+02 --- UW R015 Number of unsaturated zone strata 1 1 --- NS R015 Unsat. zone 1, thickness (m) 3.450E+00 4.000E+00 --- H(1)

R015 Unsat. zone 1, soil density (g/cm**3) 1.800E+00 1.500E+00 --- DENSUZ(1)

R015 Unsat. zone 1, total porosity 3.500E-01 4.000E-01 --- TPUZ(1)

R015 Unsat. zone 1, effective porosity 2.900E-01 2.000E-01 --- EPUZ(1)

R015 Unsat. zone 1, field capacity 6.600E-02 2.000E-01 --- FCUZ(1)

R015 Unsat. zone 1, soil-specific b parameter 9.700E-01 5.300E+00 --- BUZ(1)

R015 Unsat. zone 1, hydraulic conductivity (m/yr) 2.880E+03 1.000E+01 --- HCUZ(1)

R016 Distribution coefficients for Co-60 R016 Contaminated zone (cm**3/g) 1.161E+03 1.000E+03 --- DCNUCC( 1)

R016 Unsaturated zone 1 (cm**3/g) 1.161E+03 1.000E+03 --- DCNUCU( 1,1)

R016 Saturated zone (cm**3/g) 1.161E+03 1.000E+03 --- DCNUCS( 1)

R016 Leach rate (/yr) 0.000E+00 0.000E+00 1.022E-03 ALEACH( 1)

R016 Solubility constant 0.000E+00 0.000E+00 not used SOLUBK( 1)

R016 Distribution coefficients for Cs-134 R016 Contaminated zone (cm**3/g) 6.150E+02 4.600E+03 --- DCNUCC( 2)

R016 Unsaturated zone 1 (cm**3/g) 6.150E+02 4.600E+03 --- DCNUCU( 2,1)

R016 Saturated zone (cm**3/g) 6.150E+02 4.600E+03 --- DCNUCS( 2)

R016 Leach rate (/yr) 0.000E+00 0.000E+00 1.929E-03 ALEACH( 2)

R016 Solubility constant 0.000E+00 0.000E+00 not used SOLUBK( 2)

R016 Distribution coefficients for Cs-137 R016 Contaminated zone (cm**3/g) 6.150E+02 4.600E+03 --- DCNUCC( 3)

R016 Unsaturated zone 1 (cm**3/g) 6.150E+02 4.600E+03 --- DCNUCU( 3,1)

R016 Saturated zone (cm**3/g) 6.150E+02 4.600E+03 --- DCNUCS( 3)

R016 Leach rate (/yr) 0.000E+00 0.000E+00 1.929E-03 ALEACH( 3)

R016 Solubility constant 0.000E+00 0.000E+00 not used SOLUBK( 3)

R016 Distribution coefficients for Ni-63 R016 Contaminated zone (cm**3/g) 6.200E+01 1.000E+03 --- DCNUCC( 4)

R016 Unsaturated zone 1 (cm**3/g) 6.200E+01 1.000E+03 --- DCNUCU( 4,1)

R016 Saturated zone (cm**3/g) 6.200E+01 1.000E+03 --- DCNUCS( 4)

R016 Leach rate (/yr) 0.000E+00 0.000E+00 1.912E-02 ALEACH( 4)

R016 Solubility constant 0.000E+00 0.000E+00 not used SOLUBK( 4)

R016 Distribution coefficients for Sr-90 R016 Contaminated zone (cm**3/g) 2.300E+00 3.000E+01 --- DCNUCC( 5)

R016 Unsaturated zone 1 (cm**3/g) 2.300E+00 3.000E+01 --- DCNUCU( 5,1)

R016 Saturated zone (cm**3/g) 2.300E+00 3.000E+01 --- DCNUCS( 5)

R016 Leach rate (/yr) 0.000E+00 0.000E+00 5.076E-01 ALEACH( 5)

R016 Solubility constant 0.000E+00 0.000E+00 not used SOLUBK( 5)

RESRAD, Version 7.0 T1/2 Limit = 30 days 12/06/2014 13:09 Page 6 Summary : Zion Surface Soil 3,000 m^2 120614 File : C:\\RESRAD_FAMILY\\RESRAD\\7.0\\USERFILES\\ZION SURFACE SOIL DCGL.RAD Site-Specific Parameter Summary (continued)

User Used by RESRAD Parameter Menu Parameter Input Default (If different from user input) Name HHHHH R017 Inhalation rate (m**3/yr) 8.400E+03 8.400E+03 --- INHALR R017 Mass loading for inhalation (g/m**3) 2.350E-05 1.000E-04 --- MLINH R017 Exposure duration 3.000E+01 3.000E+01 --- ED R017 Shielding factor, inhalation 5.500E-01 4.000E-01 --- SHF3 R017 Shielding factor, external gamma 4.000E-01 7.000E-01 --- SHF1 R017 Fraction of time spent indoors 6.490E-01 5.000E-01 --- FIND R017 Fraction of time spent outdoors (on site) 1.240E-01 2.500E-01 --- FOTD R017 Shape factor flag, external gamma 1.000E+00 1.000E+00 >0 shows circular AREA. FS R017 Radii of shape factor array (used if FS = -1):

R017 Outer annular radius (m), ring 1: not used 5.000E+01 --- RAD_SHAPE( 1)

R017 Outer annular radius (m), ring 2: not used 7.071E+01 --- RAD_SHAPE( 2)

R017 Outer annular radius (m), ring 3: not used 0.000E+00 --- RAD_SHAPE( 3)

R017 Outer annular radius (m), ring 4: not used 0.000E+00 --- RAD_SHAPE( 4)

R017 Outer annular radius (m), ring 5: not used 0.000E+00 --- RAD_SHAPE( 5)

R017 Outer annular radius (m), ring 6: not used 0.000E+00 --- RAD_SHAPE( 6)

R017 Outer annular radius (m), ring 7: not used 0.000E+00 --- RAD_SHAPE( 7)

R017 Outer annular radius (m), ring 8: not used 0.000E+00 --- RAD_SHAPE( 8)

R017 Outer annular radius (m), ring 9: not used 0.000E+00 --- RAD_SHAPE( 9)

R017 Outer annular radius (m), ring 10: not used 0.000E+00 --- RAD_SHAPE(10)

R017 Outer annular radius (m), ring 11: not used 0.000E+00 --- RAD_SHAPE(11)

R017 Outer annular radius (m), ring 12: not used 0.000E+00 --- RAD_SHAPE(12)

R017 Fractions of annular areas within AREA:

R017 Ring 1 not used 1.000E+00 --- FRACA( 1)

R017 Ring 2 not used 2.732E-01 --- FRACA( 2)

R017 Ring 3 not used 0.000E+00 --- FRACA( 3)

R017 Ring 4 not used 0.000E+00 --- FRACA( 4)

R017 Ring 5 not used 0.000E+00 --- FRACA( 5)

R017 Ring 6 not used 0.000E+00 --- FRACA( 6)

R017 Ring 7 not used 0.000E+00 --- FRACA( 7)

R017 Ring 8 not used 0.000E+00 --- FRACA( 8)

R017 Ring 9 not used 0.000E+00 --- FRACA( 9)

R017 Ring 10 not used 0.000E+00 --- FRACA(10)

R017 Ring 11 not used 0.000E+00 --- FRACA(11)

R017 Ring 12 not used 0.000E+00 --- FRACA(12)

R018 Fruits, vegetables and grain consumption (kg/yr) 1.120E+02 1.600E+02 --- DIET(1)

R018 Leafy vegetable consumption (kg/yr) 2.140E+01 1.400E+01 --- DIET(2)

R018 Milk consumption (L/yr) 2.330E+02 9.200E+01 --- DIET(3)

R018 Meat and poultry consumption (kg/yr) 6.510E+01 6.300E+01 --- DIET(4)

R018 Fish consumption (kg/yr) not used 5.400E+00 --- DIET(5)

R018 Other seafood consumption (kg/yr) not used 9.000E-01 --- DIET(6)

R018 Soil ingestion rate (g/yr) 1.830E+01 3.650E+01 --- SOIL R018 Drinking water intake (L/yr) 4.780E+02 5.100E+02 --- DWI R018 Contamination fraction of drinking water 1.000E+00 1.000E+00 --- FDW R018 Contamination fraction of household water not used 1.000E+00 --- FHHW R018 Contamination fraction of livestock water 1.000E+00 1.000E+00 --- FLW R018 Contamination fraction of irrigation water 1.000E+00 1.000E+00 --- FIRW R018 Contamination fraction of aquatic food not used 5.000E-01 --- FR9 R018 Contamination fraction of plant food -1 -1 0.500E+00 FPLANT

RESRAD, Version 7.0 T1/2 Limit = 30 days 12/06/2014 13:09 Page 7 Summary : Zion Surface Soil 3,000 m^2 120614 File : C:\\RESRAD_FAMILY\\RESRAD\\7.0\\USERFILES\\ZION SURFACE SOIL DCGL.RAD Site-Specific Parameter Summary (continued)

User Used by RESRAD Parameter Menu Parameter Input Default (If different from user input) Name HHHHH R018 Contamination fraction of meat -1 -1 0.150E+00 FMEAT R018 Contamination fraction of milk -1 -1 0.150E+00 FMILK R019 Livestock fodder intake for meat (kg/day) 2.830E+01 6.800E+01 --- LFI5 R019 Livestock fodder intake for milk (kg/day) 6.520E+01 5.500E+01 --- LFI6 R019 Livestock water intake for meat (L/day) 5.060E+01 5.000E+01 --- LWI5 R019 Livestock water intake for milk (L/day) 6.000E+01 1.600E+02 --- LWI6 R019 Livestock soil intake (kg/day) 5.000E-01 5.000E-01 --- LSI R019 Mass loading for foliar deposition (g/m**3) 4.000E-04 1.000E-04 --- MLFD R019 Depth of soil mixing layer (m) 1.500E-01 1.500E-01 --- DM R019 Depth of roots (m) 1.220E+00 9.000E-01 --- DROOT R019 Drinking water fraction from ground water 1.000E+00 1.000E+00 --- FGWDW R019 Household water fraction from ground water not used 1.000E+00 --- FGWHH R019 Livestock water fraction from ground water 1.000E+00 1.000E+00 --- FGWLW R019 Irrigation fraction from ground water 1.000E+00 1.000E+00 --- FGWIR R19B Wet weight crop yield for Non-Leafy (kg/m**2) 1.750E+00 7.000E-01 --- YV(1)

R19B Wet weight crop yield for Leafy (kg/m**2) 2.900E+00 1.500E+00 --- YV(2)

R19B Wet weight crop yield for Fodder (kg/m**2) 1.900E+00 1.100E+00 --- YV(3)

R19B Growing Season for Non-Leafy (years) 2.460E-01 1.700E-01 --- TE(1)

R19B Growing Season for Leafy (years) 1.230E-01 2.500E-01 --- TE(2)

R19B Growing Season for Fodder (years) 8.200E-02 8.000E-02 --- TE(3)

R19B Translocation Factor for Non-Leafy 1.000E-01 1.000E-01 --- TIV(1)

R19B Translocation Factor for Leafy 1.000E+00 1.000E+00 --- TIV(2)

R19B Translocation Factor for Fodder 1.000E+00 1.000E+00 --- TIV(3)

R19B Dry Foliar Interception Fraction for Non-Leafy 3.500E-01 2.500E-01 --- RDRY(1)

R19B Dry Foliar Interception Fraction for Leafy 3.500E-01 2.500E-01 --- RDRY(2)

R19B Dry Foliar Interception Fraction for Fodder 3.500E-01 2.500E-01 --- RDRY(3)

R19B Wet Foliar Interception Fraction for Non-Leafy 3.500E-01 2.500E-01 --- RWET(1)

R19B Wet Foliar Interception Fraction for Leafy 5.800E-01 2.500E-01 --- RWET(2)

R19B Wet Foliar Interception Fraction for Fodder 3.500E-01 2.500E-01 --- RWET(3)

R19B Weathering Removal Constant for Vegetation 3.300E+01 2.000E+01 --- WLAM C14 C-12 concentration in water (g/cm**3) not used 2.000E-05 --- C12WTR C14 C-12 concentration in contaminated soil (g/g) not used 3.000E-02 --- C12CZ C14 Fraction of vegetation carbon from soil not used 2.000E-02 --- CSOIL C14 Fraction of vegetation carbon from air not used 9.800E-01 --- CAIR C14 C-14 evasion layer thickness in soil (m) not used 3.000E-01 --- DMC C14 C-14 evasion flux rate from soil (1/sec) not used 7.000E-07 --- EVSN C14 C-12 evasion flux rate from soil (1/sec) not used 1.000E-10 --- REVSN C14 Fraction of grain in beef cattle feed not used 8.000E-01 --- AVFG4 C14 Fraction of grain in milk cow feed not used 2.000E-01 --- AVFG5 STOR Storage times of contaminated foodstuffs (days):

STOR Fruits, non-leafy vegetables, and grain 1.400E+01 1.400E+01 --- STOR_T(1)

STOR Leafy vegetables 1.000E+00 1.000E+00 --- STOR_T(2)

STOR Milk 1.000E+00 1.000E+00 --- STOR_T(3)

STOR Meat and poultry 1.000E+00 2.000E+01 --- STOR_T(4)

STOR Fish 7.000E+00 7.000E+00 --- STOR_T(5)

STOR Crustacea and mollusks 7.000E+00 7.000E+00 --- STOR_T(6)

RESRAD, Version 7.0 T1/2 Limit = 30 days 12/06/2014 13:09 Page 8 Summary : Zion Surface Soil 3,000 m^2 120614 File : C:\\RESRAD_FAMILY\\RESRAD\\7.0\\USERFILES\\ZION SURFACE SOIL DCGL.RAD Site-Specific Parameter Summary (continued)

User Used by RESRAD Parameter Menu Parameter Input Default (If different from user input) Name HHHHH STOR Well water 1.000E+00 1.000E+00 --- STOR_T(7)

STOR Surface water 1.000E+00 1.000E+00 --- STOR_T(8)

STOR Livestock fodder 4.500E+01 4.500E+01 --- STOR_T(9)

R021 Thickness of building foundation (m) not used 1.500E-01 --- FLOOR1 R021 Bulk density of building foundation (g/cm**3) not used 2.400E+00 --- DENSFL R021 Total porosity of the cover material not used 4.000E-01 --- TPCV R021 Total porosity of the building foundation not used 1.000E-01 --- TPFL R021 Volumetric water content of the cover material not used 5.000E-02 --- PH2OCV R021 Volumetric water content of the foundation not used 3.000E-02 --- PH2OFL R021 Diffusion coefficient for radon gas (m/sec):

R021 in cover material not used 2.000E-06 --- DIFCV R021 in foundation material not used 3.000E-07 --- DIFFL R021 in contaminated zone soil not used 2.000E-06 --- DIFCZ R021 Radon vertical dimension of mixing (m) not used 2.000E+00 --- HMIX R021 Average building air exchange rate (1/hr) not used 5.000E-01 --- REXG R021 Height of the building (room) (m) not used 2.500E+00 --- HRM R021 Building interior area factor not used 0.000E+00 --- FAI R021 Building depth below ground surface (m) not used -1.000E+00 --- DMFL R021 Emanating power of Rn-222 gas not used 2.500E-01 --- EMANA(1)

R021 Emanating power of Rn-220 gas not used 1.500E-01 --- EMANA(2)

TITL Number of graphical time points 512 --- --- NPTS TITL Maximum number of integration points for dose 17 --- --- LYMAX TITL Maximum number of integration points for risk 17 --- --- KYMAX

Summary of Pathway Selections Pathway User Selection H

1 -- external gamma active 2 -- inhalation (w/o radon) active 3 -- plant ingestion active 4 -- meat ingestion active 5 -- milk ingestion active 6 -- aquatic foods suppressed 7 -- drinking water active 8 -- soil ingestion active 9 -- radon suppressed Find peak pathway doses active

RESRAD, Version 7.0 T1/2 Limit = 30 days 12/06/2014 13:09 Page 9 Summary : Zion Surface Soil 3,000 m^2 120614 File : C:\\RESRAD_FAMILY\\RESRAD\\7.0\\USERFILES\\ZION SURFACE SOIL DCGL.RAD Contaminated Zone Dimensions Initial Soil Concentrations, pCi/g Area: 3000.00 square meters Co-60 1.000E+00 Thickness: 0.15 meters Cs-134 1.000E+00 Cover Depth: 0.00 meters Cs-137 1.000E+00 Ni-63 1.000E+00 Sr-90 1.000E+00 Total Dose TDOSE(t), mrem/yr Basic Radiation Dose Limit = 2.500E+01 mrem/yr Total Mixture Sum M(t) = Fraction of Basic Dose Limit Received at Time (t) t (years): 0.000E+00 1.000E+00 3.000E+00 1.000E+01 3.000E+01 1.000E+02 3.000E+02 1.000E+03 TDOSE(t): 9.725E+00 7.962E+00 5.607E+00 2.310E+00 6.018E-01 1.790E-07 0.000E+00 1.732E-08 M(t): 3.890E-01 3.185E-01 2.243E-01 9.240E-02 2.407E-02 7.158E-09 0.000E+00 6.928E-10 Maximum TDOSE(t): 9.725E+00 mrem/yr at t = 0.000E+00 years

RESRAD, Version 7.0 T1/2 Limit = 30 days 12/06/2014 13:09 Page 10 Summary : Zion Surface Soil 3,000 m^2 120614 File : C:\\RESRAD_FAMILY\\RESRAD\\7.0\\USERFILES\\ZION SURFACE SOIL DCGL.RAD Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)

As mrem/yr and Fraction of Total Dose At t = 0.000E+00 years Water Independent Pathways (Inhalation excludes radon)

Ground Inhalation Radon Plant Meat Milk Soil Radio-Nuclide mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract.

Co-60 4.938E+00 0.5077 1.419E-06 0.0000 0.000E+00 0.0000 3.085E-02 0.0032 1.452E-02 0.0015 2.987E-03 0.0003 3.546E-04 0.0000 Cs-134 2.729E+00 0.2806 2.713E-07 0.0000 0.000E+00 0.0000 3.962E-02 0.0041 3.034E-02 0.0031 3.413E-02 0.0035 8.758E-04 0.0001 Cs-137 1.146E+00 0.1179 2.180E-07 0.0000 0.000E+00 0.0000 3.145E-02 0.0032 2.408E-02 0.0025 2.708E-02 0.0028 6.951E-04 0.0001 Ni-63 0.000E+00 0.0000 4.295E-08 0.0000 0.000E+00 0.0000 4.280E-04 0.0000 2.273E-05 0.0000 7.861E-04 0.0001 8.017E-06 0.0000 Sr-90 6.749E-03 0.0007 7.024E-06 0.0000 0.000E+00 0.0000 5.795E-01 0.0596 2.467E-02 0.0025 6.140E-02 0.0063 1.669E-03 0.0002 Total 8.820E+00 0.9069 8.975E-06 0.0000 0.000E+00 0.0000 6.819E-01 0.0701 9.363E-02 0.0096 1.264E-01 0.0130 3.602E-03 0.0004 Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)

As mrem/yr and Fraction of Total Dose At t = 0.000E+00 years Water Dependent Pathways Water Fish Radon Plant Meat Milk All Pathways*

Radio-Nuclide mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract.

Co-60 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 4.987E+00 0.5128 Cs-134 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 2.834E+00 0.2914 Cs-137 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.230E+00 0.1264 Ni-63 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.245E-03 0.0001 Sr-90 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 6.740E-01 0.0693 Total 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 9.725E+00 1.0000

  • Sum of all water independent and dependent pathways.

RESRAD, Version 7.0 T1/2 Limit = 30 days 12/06/2014 13:09 Page 11 Summary : Zion Surface Soil 3,000 m^2 120614 File : C:\\RESRAD_FAMILY\\RESRAD\\7.0\\USERFILES\\ZION SURFACE SOIL DCGL.RAD Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)

As mrem/yr and Fraction of Total Dose At t = 1.000E+00 years Water Independent Pathways (Inhalation excludes radon)

Ground Inhalation Radon Plant Meat Milk Soil Radio-Nuclide mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract.

Co-60 4.312E+00 0.5417 1.230E-06 0.0000 0.000E+00 0.0000 2.675E-02 0.0034 1.259E-02 0.0016 2.590E-03 0.0003 3.075E-04 0.0000 Cs-134 1.942E+00 0.2440 1.916E-07 0.0000 0.000E+00 0.0000 2.799E-02 0.0035 2.143E-02 0.0027 2.411E-02 0.0030 6.186E-04 0.0001 Cs-137 1.116E+00 0.1401 2.105E-07 0.0000 0.000E+00 0.0000 3.036E-02 0.0038 2.325E-02 0.0029 2.615E-02 0.0033 6.712E-04 0.0001 Ni-63 0.000E+00 0.0000 4.143E-08 0.0000 0.000E+00 0.0000 4.128E-04 0.0001 2.192E-05 0.0000 7.584E-04 0.0001 7.732E-06 0.0000 Sr-90 3.960E-03 0.0005 4.086E-06 0.0000 0.000E+00 0.0000 3.377E-01 0.0424 1.443E-02 0.0018 3.594E-02 0.0045 9.708E-04 0.0001 Total 7.375E+00 0.9263 5.760E-06 0.0000 0.000E+00 0.0000 4.232E-01 0.0532 7.172E-02 0.0090 8.955E-02 0.0112 2.576E-03 0.0003 Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)

As mrem/yr and Fraction of Total Dose At t = 1.000E+00 years Water Dependent Pathways Water Fish Radon Plant Meat Milk All Pathways*

Radio-Nuclide mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract.

Co-60 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 4.355E+00 0.5470 Cs-134 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 2.017E+00 0.2533 Cs-137 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.196E+00 0.1502 Ni-63 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.201E-03 0.0002 Sr-90 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 3.930E-01 0.0494 Total 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 7.962E+00 1.0000

  • Sum of all water independent and dependent pathways.

RESRAD, Version 7.0 T1/2 Limit = 30 days 12/06/2014 13:09 Page 12 Summary : Zion Surface Soil 3,000 m^2 120614 File : C:\\RESRAD_FAMILY\\RESRAD\\7.0\\USERFILES\\ZION SURFACE SOIL DCGL.RAD Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)

As mrem/yr and Fraction of Total Dose At t = 3.000E+00 years Water Independent Pathways (Inhalation excludes radon)

Ground Inhalation Radon Plant Meat Milk Soil Radio-Nuclide mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract.

Co-60 3.288E+00 0.5865 9.248E-07 0.0000 0.000E+00 0.0000 2.011E-02 0.0036 9.465E-03 0.0017 1.947E-03 0.0003 2.311E-04 0.0000 Cs-134 9.841E-01 0.1755 9.557E-08 0.0000 0.000E+00 0.0000 1.396E-02 0.0025 1.069E-02 0.0019 1.202E-02 0.0021 3.085E-04 0.0001 Cs-137 1.057E+00 0.1884 1.962E-07 0.0000 0.000E+00 0.0000 2.830E-02 0.0050 2.167E-02 0.0039 2.438E-02 0.0043 6.256E-04 0.0001 Ni-63 0.000E+00 0.0000 3.853E-08 0.0000 0.000E+00 0.0000 3.839E-04 0.0001 2.039E-05 0.0000 7.053E-04 0.0001 7.191E-06 0.0000 Sr-90 1.363E-03 0.0002 1.382E-06 0.0000 0.000E+00 0.0000 1.142E-01 0.0204 4.882E-03 0.0009 1.216E-02 0.0022 3.284E-04 0.0001 Total 5.330E+00 0.9507 2.637E-06 0.0000 0.000E+00 0.0000 1.770E-01 0.0316 4.672E-02 0.0083 5.121E-02 0.0091 1.501E-03 0.0003 Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)

As mrem/yr and Fraction of Total Dose At t = 3.000E+00 years Water Dependent Pathways Water Fish Radon Plant Meat Milk All Pathways*

Radio-Nuclide mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract.

Co-60 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 3.320E+00 0.5921 Cs-134 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.021E+00 0.1821 Cs-137 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.132E+00 0.2018 Ni-63 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.117E-03 0.0002 Sr-90 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.330E-01 0.0237 Total 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 5.607E+00 1.0000

  • Sum of all water independent and dependent pathways.

RESRAD, Version 7.0 T1/2 Limit = 30 days 12/06/2014 13:09 Page 13 Summary : Zion Surface Soil 3,000 m^2 120614 File : C:\\RESRAD_FAMILY\\RESRAD\\7.0\\USERFILES\\ZION SURFACE SOIL DCGL.RAD Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)

As mrem/yr and Fraction of Total Dose At t = 1.000E+01 years Water Independent Pathways (Inhalation excludes radon)

Ground Inhalation Radon Plant Meat Milk Soil Radio-Nuclide mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract.

Co-60 1.270E+00 0.5499 3.392E-07 0.0000 0.000E+00 0.0000 7.376E-03 0.0032 3.472E-03 0.0015 7.141E-04 0.0003 8.478E-05 0.0000 Cs-134 9.091E-02 0.0394 8.341E-09 0.0000 0.000E+00 0.0000 1.218E-03 0.0005 9.327E-04 0.0004 1.049E-03 0.0005 2.692E-05 0.0000 Cs-137 8.717E-01 0.3774 1.528E-07 0.0000 0.000E+00 0.0000 2.205E-02 0.0095 1.688E-02 0.0073 1.899E-02 0.0082 4.874E-04 0.0002 Ni-63 0.000E+00 0.0000 2.978E-08 0.0000 0.000E+00 0.0000 2.967E-04 0.0001 1.576E-05 0.0000 5.452E-04 0.0002 5.558E-06 0.0000 Sr-90 3.258E-05 0.0000 3.101E-08 0.0000 0.000E+00 0.0000 2.563E-03 0.0011 1.096E-04 0.0000 2.728E-04 0.0001 7.368E-06 0.0000 Total 2.233E+00 0.9666 5.612E-07 0.0000 0.000E+00 0.0000 3.350E-02 0.0145 2.141E-02 0.0093 2.157E-02 0.0093 6.120E-04 0.0003 Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)

As mrem/yr and Fraction of Total Dose At t = 1.000E+01 years Water Dependent Pathways Water Fish Radon Plant Meat Milk All Pathways*

Radio-Nuclide mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract.

Co-60 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.282E+00 0.5549 Cs-134 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 9.413E-02 0.0408 Cs-137 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 9.301E-01 0.4027 Ni-63 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 8.632E-04 0.0004 Sr-90 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 2.986E-03 0.0013 Total 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 2.310E+00 1.0000

  • Sum of all water independent and dependent pathways.

RESRAD, Version 7.0 T1/2 Limit = 30 days 12/06/2014 13:09 Page 14 Summary : Zion Surface Soil 3,000 m^2 120614 File : C:\\RESRAD_FAMILY\\RESRAD\\7.0\\USERFILES\\ZION SURFACE SOIL DCGL.RAD Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)

As mrem/yr and Fraction of Total Dose At t = 3.000E+01 years Water Independent Pathways (Inhalation excludes radon)

Ground Inhalation Radon Plant Meat Milk Soil Radio-Nuclide mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract.

Co-60 8.169E-02 0.1357 1.861E-08 0.0000 0.000E+00 0.0000 4.046E-04 0.0007 1.905E-04 0.0003 3.918E-05 0.0001 4.650E-06 0.0000 Cs-134 9.832E-05 0.0002 7.566E-12 0.0000 0.000E+00 0.0000 1.105E-06 0.0000 8.461E-07 0.0000 9.519E-07 0.0000 2.442E-08 0.0000 Cs-137 4.914E-01 0.8166 7.212E-08 0.0000 0.000E+00 0.0000 1.041E-02 0.0173 7.968E-03 0.0132 8.965E-03 0.0149 2.300E-04 0.0004 Ni-63 0.000E+00 0.0000 1.374E-08 0.0000 0.000E+00 0.0000 1.369E-04 0.0002 7.270E-06 0.0000 2.515E-04 0.0004 2.564E-06 0.0000 Sr-90 7.441E-10 0.0000 5.802E-13 0.0000 0.000E+00 0.0000 4.797E-08 0.0000 2.050E-09 0.0000 5.106E-09 0.0000 1.379E-10 0.0000 Total 5.732E-01 0.9525 1.045E-07 0.0000 0.000E+00 0.0000 1.095E-02 0.0182 8.167E-03 0.0136 9.257E-03 0.0154 2.372E-04 0.0004 Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)

As mrem/yr and Fraction of Total Dose At t = 3.000E+01 years Water Dependent Pathways Water Fish Radon Plant Meat Milk All Pathways*

Radio-Nuclide mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract.

Co-60 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 8.233E-02 0.1368 Cs-134 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.012E-04 0.0002 Cs-137 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 5.190E-01 0.8624 Ni-63 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 3.983E-04 0.0007 Sr-90 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 5.600E-08 0.0000 Total 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 6.018E-01 1.0000

  • Sum of all water independent and dependent pathways.

RESRAD, Version 7.0 T1/2 Limit = 30 days 12/06/2014 13:09 Page 15 Summary : Zion Surface Soil 3,000 m^2 120614 File : C:\\RESRAD_FAMILY\\RESRAD\\7.0\\USERFILES\\ZION SURFACE SOIL DCGL.RAD Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)

As mrem/yr and Fraction of Total Dose At t = 1.000E+02 years Water Independent Pathways (Inhalation excludes radon)

Ground Inhalation Radon Plant Meat Milk Soil Radio-Nuclide mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract.

Co-60 2.092E-14 0.0000 1.731E-21 0.0000 0.000E+00 0.0000 3.784E-13 0.0000 1.111E-12 0.0000 3.149E-13 0.0000 4.325E-19 0.0000 Cs-134 1.520E-23 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 6.634E-22 0.0000 2.173E-21 0.0000 3.838E-21 0.0000 1.457E-27 0.0000 Cs-137 2.142E-10 0.0012 1.189E-17 0.0000 0.000E+00 0.0000 1.724E-08 0.0964 5.725E-08 0.3199 1.011E-07 0.5652 3.791E-14 0.0000 Ni-63 0.000E+00 0.0000 2.092E-18 0.0000 0.000E+00 0.0000 2.096E-10 0.0012 5.352E-11 0.0003 2.812E-09 0.0157 3.904E-16 0.0000 Sr-90 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 3.982E-29 0.0000 1.650E-29 0.0000 4.589E-29 0.0000 0.000E+00 0.0000 Total 2.143E-10 0.0012 1.398E-17 0.0000 0.000E+00 0.0000 1.745E-08 0.0975 5.730E-08 0.3202 1.040E-07 0.5809 3.830E-14 0.0000 Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)

As mrem/yr and Fraction of Total Dose At t = 1.000E+02 years Water Dependent Pathways Water Fish Radon Plant Meat Milk All Pathways*

Radio-Nuclide mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract.

Co-60 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.825E-12 0.0000 Cs-134 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 6.690E-21 0.0000 Cs-137 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.759E-07 0.9826 Ni-63 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 3.075E-09 0.0172 Sr-90 2.768E-11 0.0002 0.000E+00 0.0000 0.000E+00 0.0000 1.346E-12 0.0000 3.682E-13 0.0000 7.151E-13 0.0000 3.011E-11 0.0002 Total 2.768E-11 0.0002 0.000E+00 0.0000 0.000E+00 0.0000 1.346E-12 0.0000 3.682E-13 0.0000 7.151E-13 0.0000 1.790E-07 1.0000

  • Sum of all water independent and dependent pathways.

RESRAD, Version 7.0 T1/2 Limit = 30 days 12/06/2014 13:09 Page 16 Summary : Zion Surface Soil 3,000 m^2 120614 File : C:\\RESRAD_FAMILY\\RESRAD\\7.0\\USERFILES\\ZION SURFACE SOIL DCGL.RAD Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)

As mrem/yr and Fraction of Total Dose At t = 3.000E+02 years Water Independent Pathways (Inhalation excludes radon)

Ground Inhalation Radon Plant Meat Milk Soil Radio-Nuclide mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract.

Co-60 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Cs-134 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Cs-137 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Ni-63 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Sr-90 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Total 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)

As mrem/yr and Fraction of Total Dose At t = 3.000E+02 years Water Dependent Pathways Water Fish Radon Plant Meat Milk All Pathways*

Radio-Nuclide mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract.

Co-60 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Cs-134 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Cs-137 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Ni-63 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Sr-90 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Total 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000

  • Sum of all water independent and dependent pathways.

RESRAD, Version 7.0 T1/2 Limit = 30 days 12/06/2014 13:09 Page 17 Summary : Zion Surface Soil 3,000 m^2 120614 File : C:\\RESRAD_FAMILY\\RESRAD\\7.0\\USERFILES\\ZION SURFACE SOIL DCGL.RAD Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)

As mrem/yr and Fraction of Total Dose At t = 1.000E+03 years Water Independent Pathways (Inhalation excludes radon)

Ground Inhalation Radon Plant Meat Milk Soil Radio-Nuclide mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract.

Co-60 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Cs-134 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Cs-137 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Ni-63 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Sr-90 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Total 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)

As mrem/yr and Fraction of Total Dose At t = 1.000E+03 years Water Dependent Pathways Water Fish Radon Plant Meat Milk All Pathways*

Radio-Nuclide mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract.

Co-60 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Cs-134 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Cs-137 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Ni-63 1.297E-08 0.7489 0.000E+00 0.0000 0.000E+00 0.0000 5.214E-10 0.0301 1.031E-10 0.0060 3.724E-09 0.2150 1.732E-08 1.0000 Sr-90 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Total 1.297E-08 0.7489 0.000E+00 0.0000 0.000E+00 0.0000 5.214E-10 0.0301 1.031E-10 0.0060 3.724E-09 0.2150 1.732E-08 1.0000

  • Sum of all water independent and dependent pathways.

RESRAD, Version 7.0 T1/2 Limit = 30 days 12/06/2014 13:09 Page 18 Summary : Zion Surface Soil 3,000 m^2 120614 File : C:\\RESRAD_FAMILY\\RESRAD\\7.0\\USERFILES\\ZION SURFACE SOIL DCGL.RAD Dose/Source Ratios Summed Over All Pathways Parent and Progeny Principal Radionuclide Contributions Indicated Parent Product Thread DSR(j,t) At Time in Years (mrem/yr)/(pCi/g)

(i) (j) Fraction 0.000E+00 1.000E+00 3.000E+00 1.000E+01 3.000E+01 1.000E+02 3.000E+02 1.000E+03 Co-60 Co-60 1.000E+00 4.987E+00 4.355E+00 3.320E+00 1.282E+00 8.233E-02 1.825E-12 0.000E+00 0.000E+00 Cs-134 Cs-134 1.000E+00 2.834E+00 2.017E+00 1.021E+00 9.413E-02 1.012E-04 6.690E-21 0.000E+00 0.000E+00 Cs-137+D Cs-137+D 1.000E+00 1.230E+00 1.196E+00 1.132E+00 9.301E-01 5.190E-01 1.759E-07 0.000E+00 0.000E+00 Ni-63 Ni-63 1.000E+00 1.245E-03 1.201E-03 1.117E-03 8.632E-04 3.983E-04 3.075E-09 0.000E+00 1.732E-08 Sr-90+D Sr-90+D 1.000E+00 6.740E-01 3.930E-01 1.330E-01 2.986E-03 5.600E-08 3.011E-11 0.000E+00 0.000E+00 The DSR includes contributions from associated (half-life 30 days) daughters.

Single Radionuclide Soil Guidelines G(i,t) in pCi/g Basic Radiation Dose Limit = 2.500E+01 mrem/yr Nuclide (i) t= 0.000E+00 1.000E+00 3.000E+00 1.000E+01 3.000E+01 1.000E+02 3.000E+02 1.000E+03 Co-60 5.013E+00 5.741E+00 7.530E+00 1.950E+01 3.037E+02 1.370E+13 *1.113E+15 *1.113E+15 Cs-134 8.822E+00 1.240E+01 2.448E+01 2.656E+02 2.469E+05 *1.283E+15 *1.283E+15 *1.283E+15 Cs-137 2.033E+01 2.090E+01 2.209E+01 2.688E+01 4.817E+01 1.422E+08 *8.593E+13 *8.593E+13 Ni-63 2.008E+04 2.082E+04 2.238E+04 2.896E+04 6.277E+04 8.129E+09 *5.586E+13 1.443E+09 Sr-90 3.709E+01 6.361E+01 1.880E+02 8.373E+03 4.464E+08 8.302E+11 *1.366E+14 *1.366E+14

  • At specific activity limit Summed Dose/Source Ratios DSR(i,t) in (mrem/yr)/(pCi/g) and Single Radionuclide Soil Guidelines G(i,t) in pCi/g at tmin = time of minimum single radionuclide soil guideline and at tmax = time of maximum total dose = 0.000E+00 years Nuclide Initial tmin DSR(i,tmin) G(i,tmin) DSR(i,tmax) G(i,tmax)

(i) (pCi/g) (years) (pCi/g) (pCi/g)

Co-60 1.000E+00 0.000E+00 4.987E+00 5.013E+00 4.987E+00 5.013E+00 Cs-134 1.000E+00 0.000E+00 2.834E+00 8.822E+00 2.834E+00 8.822E+00 Cs-137 1.000E+00 0.000E+00 1.230E+00 2.033E+01 1.230E+00 2.033E+01 Ni-63 1.000E+00 0.000E+00 1.245E-03 2.008E+04 1.245E-03 2.008E+04 Sr-90 1.000E+00 0.000E+00 6.740E-01 3.709E+01 6.740E-01 3.709E+01

RESRAD, Version 7.0 T1/2 Limit = 30 days 12/06/2014 13:09 Page 19 Summary : Zion Surface Soil 3,000 m^2 120614 File : C:\\RESRAD_FAMILY\\RESRAD\\7.0\\USERFILES\\ZION SURFACE SOIL DCGL.RAD Individual Nuclide Dose Summed Over All Pathways Parent Nuclide and Branch Fraction Indicated Nuclide Parent THF(i) DOSE(j,t), mrem/yr (j) (i) t= 0.000E+00 1.000E+00 3.000E+00 1.000E+01 3.000E+01 1.000E+02 3.000E+02 1.000E+03 Co-60 Co-60 1.000E+00 4.987E+00 4.355E+00 3.320E+00 1.282E+00 8.233E-02 1.825E-12 0.000E+00 0.000E+00 Cs-134 Cs-134 1.000E+00 2.834E+00 2.017E+00 1.021E+00 9.413E-02 1.012E-04 6.690E-21 0.000E+00 0.000E+00 Cs-137 Cs-137 1.000E+00 1.230E+00 1.196E+00 1.132E+00 9.301E-01 5.190E-01 1.759E-07 0.000E+00 0.000E+00 Ni-63 Ni-63 1.000E+00 1.245E-03 1.201E-03 1.117E-03 8.632E-04 3.983E-04 3.075E-09 0.000E+00 1.732E-08 Sr-90 Sr-90 1.000E+00 6.740E-01 3.930E-01 1.330E-01 2.986E-03 5.600E-08 3.011E-11 0.000E+00 0.000E+00 THF(i) is the thread fraction of the parent nuclide.

Individual Nuclide Soil Concentration Parent Nuclide and Branch Fraction Indicated Nuclide Parent THF(i) S(j,t), pCi/g (j) (i) t= 0.000E+00 1.000E+00 3.000E+00 1.000E+01 3.000E+01 1.000E+02 3.000E+02 1.000E+03 Co-60 Co-60 1.000E+00 1.000E+00 8.759E-01 6.720E-01 2.658E-01 1.877E-02 1.758E-06 5.429E-18 0.000E+00 Cs-134 Cs-134 1.000E+00 1.000E+00 7.135E-01 3.632E-01 3.418E-02 3.991E-05 2.173E-15 9.809E-45 0.000E+00 Cs-137 Cs-137 1.000E+00 1.000E+00 9.754E-01 9.280E-01 7.795E-01 4.737E-01 8.286E-02 5.690E-04 1.527E-11 Ni-63 Ni-63 1.000E+00 1.000E+00 9.743E-01 9.248E-01 7.707E-01 4.578E-01 7.395E-02 4.044E-04 4.889E-12 Sr-90 Sr-90 1.000E+00 1.000E+00 5.876E-01 2.029E-01 4.908E-03 1.182E-07 8.114E-24 0.000E+00 0.000E+00 THF(i) is the thread fraction of the parent nuclide.

RESCALC.EXE execution time = 1.67 seconds