MONTHYEARML23276A6242023-10-12012 October 2023 Summary of the Closed Meeting with PSEG Nuclear LLC and Westinghouse Electric Company to Discuss Cobalt-60 Production at Salem Nuclear Generating Station ML21277A2472021-11-0505 November 2021 Notification of Significant Licensing Action - Proposed Issuance of Order Approving the Transfer of Licenses for Which a Hearing Has Been Requested - Exelon Generation Company, LLC; Et. Al ML20150B6152020-11-23023 November 2020 Memo to File: Environmental Assessment and Finding of No Significant Impact and NRC Financial Analysis for Exelon Generation Co., LLC Decommissioning Funding Plan Submitted in Accordance with 10 CFR 72.30(b) and (C) for Salem ISFSI ML16088A2042016-03-28028 March 2016 Memo T Bowers from s Ruffin, Technical Assistance Requests - Review 2015 Tri-Annual Decommissioning Funding Plans for Multiple Independent Spent Fuel Storage Installations W/ Encl 2 (Template) ML16088A2052016-03-28028 March 2016 Enclosure 1 - (72.30 DFP Reviews to Be Completed 2015) - Memo T Bowers from s Ruffin, Technial Assistance Requests - Review 2015 Tri-Annual Decommissioning Funding Plans for Multiple Independent Spent Fuel Storage Installations ML15075A2602015-03-24024 March 2015 Request for Additional Information Spring 2014 Steam Generator Tube Inspections ML14295A3342014-10-21021 October 2014 Memo_Transmittal of NUREG-XXXX, Development of a Statistical Testing Approach for Quantifying Software Reliability and Application to an Example System. ML14167A1592014-09-0202 September 2014 Summary of Category 1 Public Meeting with Salem Nuclear Generating Station, Units 1 and 2 to Discuss Seismic Hazard Reevaluations Associated with Implementation of Japan Lessons-Learned Near-Term Task Force Recommendation 2.1 Seismic IR 05000272/20132022013-12-20020 December 2013 IR 05000272-13-202, 05000311-13-202 & 05000354-13-201, September 9-13, 2013, Salem Nuclear Generating Station and Hope Creek Generating Station - Cover Letter ML12314A1572012-11-14014 November 2012 Notice of Forthcoming Meeting with PSEG Nuclear, LLC, Regarding Final Supplemental Reponse to Generic Letter 2004-02 for Salem Generating Station, Units 1 and 2 ML13196A2202012-06-0606 June 2012 Memo from B. Balsam, NRR and D. Logan, NRR to J. Susco, NRR on Summary of Section 7 Consultation Activities Related to the National Marine Fisheries Service'S Final Rule to List the Atlantic Sturgeon ML1209002372012-03-29029 March 2012 and Salem Nuclear Generating Station, Unit Nos. 1 and 2, Draft Request for Additional Information ML1200301892012-01-0303 January 2012 Draft Request for Additional Information ML1129700652011-10-21021 October 2011 Summary of PSEG Drop-in Visit, 9-28-2011 and Slides ML1123511452011-08-24024 August 2011 Forthcoming Meeting with PSEG Nuclear LLC (PSEG) to Discuss Proposed License Amendment Regarding Reactor Coolant System Activity for Salem Nuclear Generating Station, Unit Nos. 1 and 2 ML11130A0062011-05-26026 May 2011 Summary of Telephone Conference Call Held on May 5, 2011, Between the U.S. Nuclear Regulatory Commission and PSEG Nuclear, LLC, Concerning Questions Pertaining to the Salem Nuclear Generating Station, Units 1 and 2, License Renewal Applicat ML1111601502011-04-25025 April 2011 Draft Request for Additional Information ML1111108862011-04-20020 April 2011 and Salem Nuclear Generating Station, Unit Nos. 1 and 2, Draft Request for Additional Information ML1110911182011-04-19019 April 2011 Draft Request for Additional Information ML1107606042011-04-0505 April 2011 January 25, 2011, Summary of Telephone Conference Call Held Btw the USNRC and PSEG Nuclear, LLC, Concerning Information on Buried Piping Inspections at the Salem Nuclear Generating Station, Units 1 and 2, License Renewal Application LR-N11-0087, 2011 Annual Report - Guarantees of Payment of Deferred Premiums2011-03-31031 March 2011 2011 Annual Report - Guarantees of Payment of Deferred Premiums ML1106302902011-03-0303 March 2011 Draft Request for Additional Information ML1100501452011-02-0909 February 2011 Summary of Telephone Conference Call Held on December 8, 2010, Between the U.S. Nuclear Regulatory Commission and PSEG Nuclear, LLC, Concerning Draft Response to Request for Additional Information Pertaining to the Salem Nuclear Generating ML1036307352011-02-0909 February 2011 Summary of Telephone Conference Call Held on September 16, 2010, Between the U.S. Nuclear Regulatory Commission and PSEG Nuclear LLC, Concerning Questions Pertaining to the Salem Nuclear Generating Station, Units 1 & 2, License Renewal App ML1035005662011-02-0909 February 2011 Summary of Telephone Conference Call Held on 11/18/10 Between the USNRC and PSEG Nuclear, LLC, Concerning Draft Response to the Salem Nuclear Generating Station, Units 1 and 2, Request for Additional Information, and Concerning NRC Open Ite ML1103901752011-02-0707 February 2011 Draft Request for Additional Information ML1035606562011-01-26026 January 2011 12/13/10 Summary of Telephone Conference Call Held on 12/13/10 Btw the USNRC and PSEG Nuclear, LLC, Concerning Draft Requests for Additional Information Pertaining to the Salem Nuclear Generating Station, Units 1 and 2, License Renewal Appl ML1100501562011-01-26026 January 2011 Summary of Telephone Conference Call Held on September 27, 2010, Between the U.S. Nuclear Regulatory Commission and PSEG Nuclear, LLC, Concerning Questions Pertaining to the Salem Nuclear Generating Station, Units 1 and 2 ML1035401842011-01-0707 January 2011 10/08/10 Summary of Telephone Conference Call Held Btw the USNRC and PSEG Nuclear, LLC, Concerning Questions Pertaining to the Salem Nuclear Generating Station, Units 1 and 2, License Renewal Application ML1036304612010-12-28028 December 2010 Draft Request for Additional Information ML1035404812010-12-20020 December 2010 Draft Request for Additional Information ML1030103862010-11-0505 November 2010 Advisory Committee on Reactor Safeguards Review of the Salem Nuclear Generating Station, Units 1 and 2, License Renewal Application - Safety Evaluation Report with Open Items ML1029500062010-10-28028 October 2010 11/17/10 Forthcoming Meeting to Discuss the Draft Supplemental Environmental Impact Statement for the License Renewal of Hope Creek Generating Station and Salem Nuclear Generating Station Units 1 and 2 ML1030001122010-10-27027 October 2010 Federal Register Notice Regarding the Acrs Subcommittee on Plant License Renewal (Salem), December 1, 2010 ML1026400612010-10-14014 October 2010 09/09/2010-Summary of Telephone Conference Call Between the USNRC and PSEG Nuclear, LLC, Concerning Questions Pertaining to the Salem Nuclear Generating Station, Units 1 and 2, License Renewal Application ML11263A0282010-09-16016 September 2010 E-mail with Attachment from T. Ghosh, NRR, to C. Eccleston, NRR Et Al, on Reaction Hope Creek SAMA Transmittal Memo ML11263A0272010-09-14014 September 2010 E-mail with Attachment from T. Ghosh, RES, to L. Perkins, NRR Et Al, on Fyi Salem SAMA Transmittal ML1024405922010-09-0101 September 2010 Draft Request for Additional Information ML1022200122010-08-13013 August 2010 Summary of Telephone Conf Call Held on 7/29/10, Between the USNRC and PSEG Nuclear LLC, Concerning Follow-Up Questions Pertaining to the Salem Nuclear Generating Station, Units 1 & 2, and Hope Creek Generating Station License Renewal Enviro ML1021505332010-08-0303 August 2010 Revision of July 30, 2010 - Inservice Inspection Activities Inspection Feeder for Salem Unit 1, Inspection Report 05000272/2010003 ML1029400932010-08-0303 August 2010 Memorandum to Burritt from O'Hara, Revision of July 30, 2010 - Inservice Inspection Activities Inspection Feeder for Salem Unit 1, Inspection Report 05000272-10-003 ML1029804702010-07-22022 July 2010 Memorandum from Timothy O'Hara to Arthur Burritt, Inservice Inspection Activities Inspection Feeder for Salem Unit 1, Inspection Report 05000272/2010003, Revision of July 21, 2010 ML1029801332010-07-20020 July 2010 E-Mail from Conte to Defrancisco, ISI Inspection Feeder ML1029804012010-07-15015 July 2010 Memorandum from Timothy O'Hara to Arthur Burritt, Inservice Inspection Activities Inspection Feeder for Salem Unit 1, Inspection Report 05000272/2010003 ML1029801322010-06-30030 June 2010 E-mail from Ohara to Bearde, Salem Unit 1 ISI Feeder ML1016601172010-06-14014 June 2010 Memo Salem Nuclear Generating Station, Unit No. 2, Draft Request for Additional Information ML1016006822010-06-0909 June 2010 Draft Request for Additional Information ML1015405252010-06-0808 June 2010 Notice of Meeting with PSEG Nuclear LLC, Regarding Response to Generic Letter 2004-02 for Salem Nuclear Generating Station, Units 1 and 2 ML1011004322010-04-19019 April 2010 PSEG Slides for Salem and Hope Creek Annual Assessment Meeting, April 6, 2010 LR-N10-0115, Salem, Units 1 & 2 and Hope Creek, 2010 Annual Report - Guarantees of Payment of Deferred Premiums2010-04-0101 April 2010 Salem, Units 1 & 2 and Hope Creek, 2010 Annual Report - Guarantees of Payment of Deferred Premiums 2023-10-12
[Table view] Category:Conference/Symposium/Workshop Paper
MONTHYEARML13109A2352013-05-10010 May 2013 Summary of Conference Call Regarding the Fall 2012 Steam Generator Tube Inspections at Salem Nuclear Generating Station, Unit No. 2 ML1107608982011-04-0505 April 2011 January 12, 2011, Summary of Telephone Conference Call Held Between the U.S. Nuclear Regulatory Commission and PSEG Nuclear, Llx, Concerning Audit of the Westems Software Pertaining to the Salem Nuclear Generating Station, Units 1 and 2, LR ML1107606042011-04-0505 April 2011 January 25, 2011, Summary of Telephone Conference Call Held Btw the USNRC and PSEG Nuclear, LLC, Concerning Information on Buried Piping Inspections at the Salem Nuclear Generating Station, Units 1 and 2, License Renewal Application ML1035401842011-01-0707 January 2011 10/08/10 Summary of Telephone Conference Call Held Btw the USNRC and PSEG Nuclear, LLC, Concerning Questions Pertaining to the Salem Nuclear Generating Station, Units 1 and 2, License Renewal Application ML1032102502010-12-13013 December 2010 10/22/10 Summary of Telephone Conference Call Held Btw the USNRC and PSEG Nuclear LLC Concerning Questions Pertaining to the Salem Nuclear Generating Station, Units 1 and 2, License Renewal Application ML1024600952010-10-14014 October 2010 Summary of Telephone Conference Call Held Between Us NRC and PSEG Nuclear, LLC Concerning Questions Pertaining to the Salem Nuclear Generation Station Units 1&2 LRA ML1023200572010-09-0303 September 2010 8/16/10 Summary of Telephone Conference Call Held Between the USNRC and PSEG Nuclear LLC Concerning a D-RAI Pertaining to the Salem Nuclear Generating Station, Units 1 and 2, License Renewal Application ML1022900442010-08-31031 August 2010 Summary of Conference Call Regarding Spring 2010 Steam Generator Tube Inspections at Salem Nuclear Generating Station, Unit No. 1 ML1022305122010-08-18018 August 2010 08/04/10 Summary of Telephone Conference Call Held on Between NRC and PSEG Nuclear, LLC, Concerning Drais Pertaining to the Salem Nuclear Generating Station, Units 1 and 2, License Renewal Application 2013-05-10
[Table view] Category:Meeting Summary
MONTHYEARML23276A6242023-10-12012 October 2023 Summary of the Closed Meeting with PSEG Nuclear LLC and Westinghouse Electric Company to Discuss Cobalt-60 Production at Salem Nuclear Generating Station ML23179A0012023-06-28028 June 2023 6/7/2023 - Annual Assessment Meeting for Pa/Md/Ny/Nj Nuclear Power Plants - Meeting Summary ML23146A1012023-05-31031 May 2023 Summary of May 25, 2023, Pre-Submittal Public Meeting with PSEG Nuclear LLC to Discuss Reduction of the Site'S Exclusion Area Boundary ML22187A1462022-07-0606 July 2022 Joint Annual Assessment Meeting for Pa/Md/Nj/Ny Nuclear Power Plants - Meeting Summary ML22153A4492022-06-14014 June 2022 Summary of Pre-Submittal Public Meeting with PSEG Nuclear LLC to Extend Emergency Diesel Generator Allowed Outage Time ML21201A0702021-08-0505 August 2021 Summary of July 20, 2021, Meeting with the National Marine Fisheries Service Regarding Incidental Take of Kemps Ridley Sea Turtles at Salem Nuclear Generating Station, Units 1 and 2 ML21064A0962021-03-0909 March 2021 Summary of 3/4/2021 Pre-Submittal Public Meeting with PSEG Nuclear LLC to Discuss Adoption of ASME Section XI Code Cases N-878, N-879, and N-880 at Hope Creek Generating Station and Salem Nuclear Generating Station ML20204A8422020-07-28028 July 2020 Summary of July 20, 2020, Pre-Submittal Public Meeting with PSEG Nuclear LLC to Discuss Proposed Relief Request for Pressurizer Weld Interval Extension ML20125A1652020-05-0404 May 2020 Summary of April 23, 2020, Teleconference with NMFS Regarding Incidental Take of Atlantic Sturgeon at Salem Nuclear Generating Station ML20113F0892020-04-27027 April 2020 Summary of April 15, 2020, Pre-Submittal Meeting with PSEG Nuclear LLC to Discuss Proposed License Amendment on Leak Before Break Analyses ML20108F0652020-04-17017 April 2020 Summary of April 15, 2020, Teleconference with PSEG Nuclear, LLC Regarding Incidental Take of Atlantic Sturgeon at Salem ML19109A1282019-04-16016 April 2019 and Hope Creek Generating Station: Summary of Public Webinar Meeting on April 10, 2019 ML18156A4242018-06-0505 June 2018 Annual Assessment Meeting, 5/30/18 Meeting Summary ML18044A9942018-02-26026 February 2018 Summary of Meeting with PSEG Nuclear LLC Regarding Planned Submittal of License Amendment Request to Revise Technical Specifications Regarding Extending the Allowed Outage Time for the Inverters ML17332A6032017-12-0404 December 2017 Summary of October 27, 2017, Conference Call with PSEG Nuclear LLC Fall 2017 Steam Generator Inspections ML17206A0282017-08-0707 August 2017 Summary of 7/19/17 Meeting with PSEG Planned Submittal of License Amendment Request to Revise Technical Specifications for Reactor Trip and Engineered Safety Feature Actuation System Instrumentation for Salem, Units 1 and 2 (CAC Nos. MF9900 ML17102A7772017-04-10010 April 2017 Summary of Annual Assessment Meeting with PSEG ML16347A3932017-01-0505 January 2017 Summary of Teleconference with PSEG Nuclear LLC Regarding Planned License Amendment Request Regarding Change to the Salem Nuclear Generating Station-Hope Creek Generating Station Emergency Action Levels (MF8875, MF8876, and MF8877) ML16123A1322016-05-17017 May 2016 Summary of Public Pre-Application Meeting Held on March 30, 2016, with PSEG LLC to Discuss License Amendment Request Containment Fan Coil Unit Allowed Outage Time at Salem Nuclear Generating Station, Unit Nos. 1 and 2 ML16096A2222016-04-0505 April 2016 March 30, 2016, Summary of Annual Assessment Meeting with PSEG - Salem Nuclear Generating Station & Hope Creek Generating Station ML16035A4802016-02-12012 February 2016 Jsc Meeting Summary Attachment ML15202A2432015-07-29029 July 2015 June 24, 2015, Summary of Pre-Submittal Meeting with PSEG Nuclear LLC on Upgrades and Maintenance to the Chilled Water System at Salem Nuclear Generating Station, Unit Nos. 1 and 2 ML15104A1492015-04-14014 April 2015 Hope, Summary of Annual Assessment Meeting with PSEG ML14167A1592014-09-0202 September 2014 Summary of Category 1 Public Meeting with Salem Nuclear Generating Station, Units 1 and 2 to Discuss Seismic Hazard Reevaluations Associated with Implementation of Japan Lessons-Learned Near-Term Task Force Recommendation 2.1 Seismic ML14100A0242014-04-10010 April 2014 Salem and Hope Creek - Summary of Annual Assessment Meeting with PSEG ML13109A2352013-05-10010 May 2013 Summary of Conference Call Regarding the Fall 2012 Steam Generator Tube Inspections at Salem Nuclear Generating Station, Unit No. 2 ML13099A3242013-04-0909 April 2013 Salem & Hope Creek - Summary of Annual Assessment Meeting with PSEG ML13078A4482013-04-0505 April 2013 Summary of February 28, 2013, Public Meeting with PSEG Final Supplemental Response to Generic Letter 2004-02 for Salem Nuclear Generating Station, Units 1 and 2 ML12144A3312012-05-23023 May 2012 Summary of Meeting at the PSEG to Discuss the Nrc'S Assessment of Pseg'S Safety Performance at Salem & Hope Creek for 2011 ML1129700652011-10-21021 October 2011 Summary of PSEG Drop-in Visit, 9-28-2011 and Slides ML1125200382011-09-19019 September 2011 Summary of, Meeting with PSEG Nuclear LLC to Discuss Proposed License Amendment Regarding Reactor Coolant System Activity for Salem Nuclear Generating Station, Unit Nos. 1 and 2 ML11139A3462011-05-26026 May 2011 Summary of Telephone Conference Call Held on May 10, 2011, Between the NRC and Nuclear, LLC, Concerning a Draft Response to a Draft RAI Pertaining to the Salem Nuclear Generating Station, Units 1 and 2, (Salem) License Renewal Application ML1114002132011-05-20020 May 2011 Summary of Annual Assessment Meeting for Salem and Hope Creek ML1107608982011-04-0505 April 2011 January 12, 2011, Summary of Telephone Conference Call Held Between the U.S. Nuclear Regulatory Commission and PSEG Nuclear, Llx, Concerning Audit of the Westems Software Pertaining to the Salem Nuclear Generating Station, Units 1 and 2, LR ML1107606042011-04-0505 April 2011 January 25, 2011, Summary of Telephone Conference Call Held Btw the USNRC and PSEG Nuclear, LLC, Concerning Information on Buried Piping Inspections at the Salem Nuclear Generating Station, Units 1 and 2, License Renewal Application ML1107007082011-04-0505 April 2011 February 17, 2011, Summary of Telephone Conference Call Held Between NRC and PSEG, Concerning Information on the Salem Nuclear Generating Station, Units 1 and 2, License Renewal Application ML1036307352011-02-0909 February 2011 Summary of Telephone Conference Call Held on September 16, 2010, Between the U.S. Nuclear Regulatory Commission and PSEG Nuclear LLC, Concerning Questions Pertaining to the Salem Nuclear Generating Station, Units 1 & 2, License Renewal App ML1035005662011-02-0909 February 2011 Summary of Telephone Conference Call Held on 11/18/10 Between the USNRC and PSEG Nuclear, LLC, Concerning Draft Response to the Salem Nuclear Generating Station, Units 1 and 2, Request for Additional Information, and Concerning NRC Open Ite ML1100501562011-01-26026 January 2011 Summary of Telephone Conference Call Held on September 27, 2010, Between the U.S. Nuclear Regulatory Commission and PSEG Nuclear, LLC, Concerning Questions Pertaining to the Salem Nuclear Generating Station, Units 1 and 2 ML1035606562011-01-26026 January 2011 12/13/10 Summary of Telephone Conference Call Held on 12/13/10 Btw the USNRC and PSEG Nuclear, LLC, Concerning Draft Requests for Additional Information Pertaining to the Salem Nuclear Generating Station, Units 1 and 2, License Renewal Appl ML1035401842011-01-0707 January 2011 10/08/10 Summary of Telephone Conference Call Held Btw the USNRC and PSEG Nuclear, LLC, Concerning Questions Pertaining to the Salem Nuclear Generating Station, Units 1 and 2, License Renewal Application ML1032102502010-12-13013 December 2010 10/22/10 Summary of Telephone Conference Call Held Btw the USNRC and PSEG Nuclear LLC Concerning Questions Pertaining to the Salem Nuclear Generating Station, Units 1 and 2, License Renewal Application ML1026400612010-10-14014 October 2010 09/09/2010-Summary of Telephone Conference Call Between the USNRC and PSEG Nuclear, LLC, Concerning Questions Pertaining to the Salem Nuclear Generating Station, Units 1 and 2, License Renewal Application ML1024600952010-10-14014 October 2010 Summary of Telephone Conference Call Held Between Us NRC and PSEG Nuclear, LLC Concerning Questions Pertaining to the Salem Nuclear Generation Station Units 1&2 LRA ML1023200572010-09-0303 September 2010 8/16/10 Summary of Telephone Conference Call Held Between the USNRC and PSEG Nuclear LLC Concerning a D-RAI Pertaining to the Salem Nuclear Generating Station, Units 1 and 2, License Renewal Application ML1022900442010-08-31031 August 2010 Summary of Conference Call Regarding Spring 2010 Steam Generator Tube Inspections at Salem Nuclear Generating Station, Unit No. 1 ML1022305122010-08-18018 August 2010 08/04/10 Summary of Telephone Conference Call Held on Between NRC and PSEG Nuclear, LLC, Concerning Drais Pertaining to the Salem Nuclear Generating Station, Units 1 and 2, License Renewal Application ML1022200122010-08-13013 August 2010 Summary of Telephone Conf Call Held on 7/29/10, Between the USNRC and PSEG Nuclear LLC, Concerning Follow-Up Questions Pertaining to the Salem Nuclear Generating Station, Units 1 & 2, and Hope Creek Generating Station License Renewal Enviro ML1018004772010-07-14014 July 2010 Summary of Category 1 Public Meeting with PSEG Nuclear LLC, Regarding Response to Generic Letter 2004-02 for Salem Nuclear Generating Station, Units 1 and 2 ML1016806422010-06-17017 June 2010 Summary of Public Meeting Between Nuclear Regulatory Commission Staff and PSEG Nuclear, LLC to Discuss the Status and Scheduling for the Independent Spent Fuel Storage Installation (ISFSI) 2023-06-28
[Table view] |
Text
\.t.p.fI REG(J
.;:,V ('1 UNITED STATES
~
l~.>~O~
....
<fl
('l 0
~
NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555-0001 0.,. ~
~ Ii; v;;... "" January 7, 2011
-"" ~O'
LICENSEE: PSEG Nuclear, LLC FACILITY: Salem Nuclear Generating Station, Units 1 and 2
SUBJECT:
SUMMARY
OF TELEPHONE CONFERENCE CALL HELD ON OCTOBER 8,2010, BETWEEN THE U.S. NUCLEAR REGULATORY COMMISSION AND PSEG NUCLEAR, LLC, CONCERNING QUESTIONS PERTAINING TO THE SALEM NUCLEAR GENERATING STATION, UNITS 1 AND 2, LICENSE RENEWAL APPLICATION The U.S. Nuclear Regulatory Commission (NRC or the staff) and representatives of PSEG Nuclear, LLC (the applicant), and Exelon held a telephone conference call on October 8,2010, to discuss and clarify the staffs questions concerning the Salem Nuclear Generating Station, Units 1 and 2, license renewal application. The telephone conference call was useful in clarifying the intent of the staff's questions.
Enclosure 1 provides a listing of the participants, Enclosure 2 contains a brief summary of the discussion and status of the items, and Enclosure 3 contains the staffs draft request for additional information and the applicant's questions for clarification.
The applicant had an opportunity to comment on this summary.
~~/~
Bennett M. Brady, Project Manager Projects Branch 1 Division of License Renewal Office of Nuclear Reactor Regulation Docket Nos. 50-272 and 50-311
Enclosures:
- 1. List of Participants
- 2. Summary of meeting discussion
- 3. Draft RAJ and questions for clarification cc w/encls: Distribution via Listserv
TELEPHONE CONFERENCE CALL SALEM NUCLEAR GENERATING STATION, UNITS 1 AND 2 LICENSE RENEWAL APPLICATION LIST OF PARTICIPANTS October 8,2010 PARTICIPANTS AFFILIATIONS Bennett Brady U.S. Nuclear Regulatory Commission (NRC)
Louise Lund NRC Allen Hiser NRC Gary Stevens NRC OnYee NRC Ching Ng NRC Christopher Wilson Exelon Sam Speer Exelon ENCLOSURE 1
SUMMARY
OF MEETING ON QUESTIONS ON THE SALEM NUCLEAR GENERATING STATION. UNITS 1 AND 2 LICENSE RENEWAL APPLICATION OCTOBER 8, 2010 The U.S. Nuclear Regulatory Commission (NRC or the staff) and representatives of PSEG Nuclear, LLC held a telephone conference call on October 8, 2010, to discuss and clarify the NRC's request for additional information (RAI) related to the WESTEMSTM software that is used for monitoring and analyzing metal fatigue.
Discussion:
Prior to the meeting, the staff had provided the applicant with their draft RAI as shown in . The applicant provided the NRC staff with their questions for clarification on the draft RAI as shown in Enclosure 3.
During the meeting, the staff and applicant agreed that the NRC needed more information on the background and chorology of Salem Nuclear Generating Station's metal fatigue analyses and the use ofWESTEMSTM for monitoring and analyzing metal fatigue. The meeting agreed that the NRC would revise their RAI and provide it to the applicant for further discussion.
ENCLOSURE 2
DRAFTRAI
Background:
Section 4.3.4.2 of the Salem License Renewal Application (LRA) credits the WESTEMS code for evaluation of fatigue for the pressurizer and surge line locations. For example, Section A.3.1.1 of the Salem LRA identifies WESTEMS as a part of the Metal Fatigue of Reactor Pressure Boundary program.
Issue:
The staff has identified concerns regarding the results determined by the WESTEMS program as a part of the American Society of Mechanical Engineers Boiler and Pressure Vessel Code (ASME Code) fatigue evaluation process. For example, Westinghouse's response to U.S. Nuclear Regulatory Commission (NRC) questions regarding the AP1000 Technical Report (see Agencywide Documents Accession and Management System (ADAMS) Accession Number ML102300072, dated August 13, 2010) describe the ability of users to modify intermediate data (peak and valley stresses/times) used in the analyses. In addition, a response provided on August 20, 2010, (ADAMS Accession Number ML102350440) describes different approaches for summation of moment stress terms. These items can have significant impacts on calculated fatigue cumUlative usage factor (CUF). The potential impact for modifications such as these formed the basis for the staff's conclusions in Regulatory Issue Summary (RIS) 2008-30, "Fatigue Analysis of Nuclear Power Plant Components," dated December 16, 2008, where it was noted that simplification of the analysis requires a great deal of judgment by the analyst to ensure that the simplification still provides a conservative result.
The staff recognizes that WESTEMS has been developed under a formal Quality Assurance Program with supporting Technical Bases; however, it is difficult to ascertain the accuracy or conservatism of a component-specific application of WESTEMS given that a variety of analyst judgments may still be applied to the software outputs by the user on a case-specific basis.
Request:
The staff requests that Salem provide a benchmarking evaluation of the component-specific application of the Salem pressurizer and surge line locations monitored in WESTEMS using the same input parameters and assumptions as those used in the current licensing basis (CLB) analysis of record performed for each location in accordance with the ASME Code,Section III.
The intent of this benchmarking evaluation is to confirm that the results of the WESTEMS model are acceptable and conservative compared to the CLB analysis of record for each of the monitored locations.
Provide a summary of the benchrnarking evaluation that includes the following information:
- A comparison of the calculated stresses and CUF for each location using the WESTEMS system for each transient pair that contributes to the CUF to the same results from the CLB analysis of record.
- Describe the differences in the results between the WESTEMS evaluation and the CLB analysis of record for each location, and provide a justification for acceptability of the differences.
ENCLOSURE 3
-2 Clarification Questions on Salem WESTEMS ' RAJ Background Information:
As discussed in Salem LRA Section 4.3.4.2, the pressurizer surge line piping and nozzles were previously evaluated for the effects of thermal stratification and plant-specific transients. In a later evaluation, a plant-specific WESTEMSTM model was developed for the pressurizer [lower head] and surge line to evaluate the effects of pressurizer insurge and outsurge transients.
The first evaluation was documented in WCAP-12913 (non-proprietary) and WCAP-12914 (proprietary), and submitted to the NRC in PSE&G Letter NLR-91 083, dated May 15, 1991.
This evaluation used four software codes, including ANSYS, but not WESTEMSTM, to conduct the ASME Code Section III, NB-3200, 1986 edition, evaluation.
The second evaluation is documented in WCAP-16194, and looked specifically at the Pressurizer lower head and surge nozzle. This evaluation used WESTEMSTM, Version 4.2, which conducted the evaluation in accordance with ASME Code Section III, NB-3200, 1989 edition. This evaluation was not submitted to the NRC, or referenced in the CLB. However, it is the current design basis for the pressurizer lower head and surge nozzle.
Specific Questions for Clarification to Respond:
- 1. The Request is to provide a summary of a benchmarking evaluation. Is the benchmarking being requested specifically for the stress and fatigue models used to calculate fatigue usage for the Salem pressurizer and surge line locations in the WESTEMSTM online monitoring system, i.e., the lower head, surge nozzle region that were evaluated in WCAP-16194? Or does the benchmark consider the WESTEMSTM models used in the Salem Environmentally-Assisted Fatigue (EAF) calculations for the pressurizer nozzle and surge line hot leg nozzle locations?
- 2. As contained in the supporting calculations for the Salem LRA, the WESTEMS '
monitoring models for the pressurizer surge nozzle and surge line hot leg nozzle locations were bench marked against ANSYS with respect to the stress responses
[calculated stresses indicated in your first bullet] generated by WESTEMSTM for transient loadings.
The models are then used in the monitoring system to calculate fatigue usage automatically from all stress peaks and valleys identified in the operating history for each location, according to the ASME Code Section III methodology. In the monitoring role, there is no user post-processing of peaks and valleys or reanalysis of fatigue usage.
Therefore, the concern regarding application of analyst judgments noted in the RAI Issue description is not applicable for WESTEMSTM monitoring models. The analyst{s) did edit peaks during the preparation of the Salem EAF calculations, and the final peaks used in the calculations were documented and verified.
-3 Also, the concern noted in the RAllssue description with respect to summation of moments is only applicable to the WESTEMSTM NB-3600 analysis module, which is not used in WESTEMSTM monitoring, or in the Salem EAF calculations. In addition, the subject of RIS 2008-30 was fatigue evaluation using simplified single component stress models, which is not employed in WESTEMSTM monitoring or EAF calculation models, and is therefore not applicable. The WESTEMSTM models and fatigue calculations evaluate all components of stress according to NB-3200.
In light of these points, are the existing benchmarks performed for the models and documented in the Salem EAF calculations sufficient to satisfy the component specific benchmarking requested? If so, Salem will use these to provide the requested benchmark comparison.
- 3. As is the case with most stress and fatigue analyses in the industry, the CLB analyses of record may have been done in a more conservative manner than may be performed in later analyses. As long as the later analyses are performed in accordance with the ASME Code, it is not required that their results are conservative with respect to the earlier CLB analyses. In light of this, it is not clear why the request states that the benchmark should intend to show that the WESTEMSTM results are conservative compared to the CLB analysis of record.
- 4. Depending upon the location(s) of interest to the Staff, the CLB analysis of record was performed using either a combination of four software codes (WCAP-12913), or with an earlier version of WESTEMSTM (WCAP-16194). If the benchmark is with the earlier version of WESTEMS TM, then the requested benchmarking would be trivial. Salem is requesting the Staff to consider the existing benchmarking in the component model calculations as sufficient for your review on this issue.
January 7, 2011 LICENSEE: PSEG Nuclear, LLC FACILITY: Salem Nuclear Generating Station, Units 1 and 2
SUBJECT:
SUMMARY
OF TELEPHONE CONFERENCE CALL HELD ON OCTOBER 8,2010, BETWEEN THE U.S. NUCLEAR REGULATORY COMMISSION AND PSEG NUCLEAR, LLC, CONCERNING QUESTIONS PERTAINING TO THE SALEM NUCLEAR GENERATING STATION, UNITS 1 AND 2, LICENSE RENEWAL APPLICATION The U.S. Nuclear Regulatory Commission (NRC or the staff) and representatives of PSEG Nuclear, LLC (the applicant), and Exelon held a telephone conference call on October 8, 2010, to discuss and clarify the staff's questions concerning the Salem Nuclear Generating Station, Units 1 and 2, license renewal application. The telephone conference call was useful in clarifying the intent of the staff's questions. provides a listing of the participants, Enclosure 2 contains a brief summary of the discussion and status of the items, and Enclosure 3 contains the staff's draft request for additional information and the applicant's questions for clarification.
The applicant had an opportunity to comment on this summary.
IRA!
Bennett M. Brady, Project Manager Projects Branch 1 Division of License Renewal Office of Nuclear Reactor Regulation Docket Nos. 50-272 and 50-311
Enclosures:
- 1. List of Participants
- 2. Summary of meeting discussion
- 3. Draft RAI and questions for clarification cc w/encls: Distribution via Listserv DISTRIBUTION:
See next page ADAMS Accession Number: ML103540184 OFFICE LA: DLR PM: DLR/RPB1 BC: DLRlRPB1 PM: DLRlRPB1 NAME IKing BBrady BPham BBrady DATE 12/30/2010 01/05/2011 01/06/2011 01/07/2011
. - .. ,
Memorandum to PSEG Nuclear, LLC from Bennett M. Brady dated January 07,2011
SUBJECT:
SUMMARY
OF TELEPHONE CONFERENCE CALL HELD ON OCTOBER 8,2010, BETWEEN THE U.S. NUCLEAR REGULATORY COMMISSION AND PSEG NUCLEAR, LLC, CONCERNING QUESTIONS PERTAINING TO THE SALEM NUCLEAR GENERATION STATION, UNITS 1 AND 2, LICENSE RENEWAL APPLICATION DISTRIBUTION:
HARD COPY:
DLRRF E-MAIL:
PUBLIC RidsNrrDlr Resource RidsNrrDlrRpb1 Resource RidsNrrDlrRpb2 Resource RdsNrrDlrRarb Resource RidsNrrDlrRasb Resource RidsNrrDlrRapb Resource RidsOgcMailCenter Resource BPham BBrady ACunanan SCuadrado CEccleston REnnis CSanders BHarris, OGC ABurritt, RI RConte, RI MModes, RI DTifft, RI NMcNamara, RI