MONTHYEARIR 05000280/20244012024-02-0606 February 2024 Security Baseline Inspection Report 05000280/2024401, 05000281/2024401 and 07200002/2024401 IR 05000280/20230102024-01-18018 January 2024 Age Related Degradation Inspection Report 05000280-2023010 and 05000281-2023010 ML23312A1922024-01-18018 January 2024 Issuance of Amendment Nos. 316 & 316 Regarding a Risk Informed Approach for Tornado Classification of the Fuel Handling Trolley Support Structure ML24003A9022024-01-0303 January 2024 Stations, Units 1 and 2, Emergency Plan Revision - Relocation of the Technical Support Center (TSC) - Editorial Correction IR 05000280/20233012023-12-28028 December 2023 NRC Operator License Examination Report 05000280/2023301 and 05000281/2023301 ML23283A3052023-12-20020 December 2023 Review of Appendix F to DOM-NAF2, Qualification of the Framatome ORFEO-GAIA and ORFEO-NMGRID CHF Correlations in the Dominion Energy VIPRE-D Computer Code (EPID L-2022-LLT-0003) (Nonproprietary) ML23352A3692023-12-18018 December 2023 Associated Independent Spent Fuel Storage Installation, Revision to Emergency Plan Report of Change ML23334A2342023-11-30030 November 2023 Request for Exemption from Enhanced Weapons, Firearms Background Checks, and Security Event Notifications Implementation ML23242A2292023-11-0707 November 2023 Issuance of Amendment Nos. 315 and 315, Regarding Emergency Procedure Relocation of the Technical Support Center ML23200A2622023-11-0202 November 2023 Issuance of Amendment Nos. 314 and 314, Regarding Technical Specification and Spent Fuel Pool Criticality Change IR 05000280/20230032023-10-25025 October 2023 Integrated Inspection Report 05000280/2023003 and 05000281/2023003 ML23286A0372023-10-13013 October 2023 Annual Submittal of Technical Specifications Bases Changes Pursuant to Technical Specification 6.4.J ML23285A0922023-10-12012 October 2023 Inservice Testing Program for Pumps and Valves Sixth Interval Update and Associated Relief and Alternative Requests ML23277A1172023-10-0303 October 2023 Operator Licensing Examination Approval 05000280/2023301 and 05000281/2023301 ML23230A0502023-10-0202 October 2023 5 of the Quality Assurance Topical Report - Review of Program Changes ML23256A2672023-09-21021 September 2023 Review of the Fall 2022 Steam Generator Tube Inspection Report ML23244A2352023-09-18018 September 2023 Request to Use a Subsequent Edition of the ASME Code, Section XI ML23230A0012023-09-15015 September 2023 Request to Use a Provision of a Previous Edition of the ASME Boiler and Pressure Vessel Code, Section XI, for Non-Destructive Examinations IR 05000280/20220042023-09-0101 September 2023 Reissue - Surry Power Station - Integrated Inspection Report 05000280/2022004 and 05000281/2022004 ML23244A0142023-08-30030 August 2023 Inservice Inspection Owner'S Activity Report IR 05000280/20230052023-08-23023 August 2023 Updated Inspection Plan for Surry Power Station, Units 1 and 2 (Report 05000280/2023005 and 05000281/2023005) ML23226A1862023-08-10010 August 2023 Proposed License Amendment Request - Reclassification of Regulatory Guide 1.97 Variable for Low Head Safety Injection Flow Instrumentation ML23220A1492023-08-0707 August 2023 Independent Spent Fuel Storage Installation - Submittal of Cask Registrations for Spent Fuel Storage ML23220A1482023-08-0707 August 2023 Proposed Emergency Plan Revision - Relocation of the Technical Support Center (TSC) Response to Request for Additional Information IR 05000280/20230022023-08-0404 August 2023 Integrated Inspection Report 05000280/2023002 and 05000281/2023002 ML23208A0922023-07-26026 July 2023 Request for Approval of Appendix F of Fleet Report DOM-NAF-2-P Qualification of Framatome ORFEO-GAIA and OORFE-NMGRID CHF Correlations in the Dominion Energy Vipre-D Computer Code Response ML23207A1102023-07-26026 July 2023 NRC Regulatory Issues Summary 2023-01 Preparation and Scheduling of Operator Licensing Examinations ML23198A0322023-07-18018 July 2023 Regulatory Audit Report Regarding Review of License Amendment to Modify Emergency Plan Staff Augmentation Times ML23193A9382023-07-18018 July 2023 Closeout of Generic Letter 2004-02, Potential Impact of Debris Blockage on Emergency Recirculation During Design Basis Accidents at Pressurized-Water Reactors ML23173A0602023-07-11011 July 2023 Audit Summary for License Amendment Request Revision of the Emergency Plan to Support Relocation of the Technical Support Center ML23136B1392023-06-29029 June 2023 Issuance of Amendment No. 313 Administrative Changes to Subsequent Renewed Operating Licenses and Technical Specifications ML23178A1682023-06-26026 June 2023 2022 Annual Report of Emergency Core Cooling System (ECCS) Model Changes Pursuant to the Requirements of 10 CFR 50.46 ML23152A0432023-06-22022 June 2023 Audit Plan License Amendment Requests to Change Emergency Plan Staff Augmentation Times ML23153A1732023-06-16016 June 2023 Correction to Amendment Nos. 346 & 286 Millstone, 294 & 277 North Anna, 311 & 311 Surry, and 225 Summer to Revise Technical Specifications to Adopt TSTF-554,Rev Reactor Coolant Leakage Requirement ML23163A2352023-06-12012 June 2023 Request to Use a Later Edition of the ASME Boiler and Pressure Vessel Code, Section XI, for the SPS Sixth Inservice Inspection (Isi) Intervals and VCSNS Fifth ISI Interval ML23151A6612023-05-31031 May 2023 ES-2.1-1, Surry 2023-301 Corporate Notification Letter (Revised) ML23167B0072023-05-31031 May 2023 Proposed Emergency Plan Revision - Relocation of the Technical Support Center (TSC) Supplemental Information - LOCA Dose Calculation Summary ML23117A0952023-05-10010 May 2023 Audit Plan License Amendment Request to Support Relocation of the Technical Support Center ML23130A3742023-05-10010 May 2023 Request to Delay NRC Intial Licensing Examination 2024-02-06
[Table view] Category:Operating Report
MONTHYEARML22076A0182022-03-16016 March 2022 Annual Changes, Tests, and Experiments Report - Regulatory Commitment Evaluation Report ML22066A4842022-03-0909 March 2022 Review of the Spring 2021 Steam Generator Tube Inspection Report ML0623703502006-08-18018 August 2006 Owner'S Activity Report ML0209903272002-03-28028 March 2002 Cycle 18 Core Operating Limits Report ML19105A3031978-09-13013 September 1978 Submit Monthly Operating Report for the Month of August 1978 ML19095A3811978-09-13013 September 1978 Submit Operating Report for Month of August 1978 ML19105A3081978-01-0909 January 1978 Submit Monthly Operating Report for the Month of December 1977 ML19105A3091977-12-0808 December 1977 Submit Monthly Operating Report for the Month of November 1977 ML19105A3101977-11-10010 November 1977 Submit Monthly Operating Report for the Month of October 1977 ML19105A3111977-10-11011 October 1977 Submit Monthly Operating Report for the Month of September 1977 ML19105A3131977-08-0909 August 1977 Submit Monthly Operating Report for the Month of July 1977 ML19095A3761977-08-0909 August 1977 Submit Operating Information for Month of July 1977 ML19095A3771977-07-0808 July 1977 Submit Operating Information for Month of June 1977 ML19095A3781977-07-0808 July 1977 Submit Operating Information for Month of June 1977 ML19095A3791977-06-0808 June 1977 Submit Operating Information for Month of May 1977 ML19105A3151977-06-0808 June 1977 Submit Monthly Operating Report for the Month of May 1977 ML19095A3111977-05-0909 May 1977 Submit Operating Report for the Month of April 1977 ML19105A3161977-05-0909 May 1977 Submit Monthly Operating Report for the Month of April 1977 ML19095A3121977-03-10010 March 1977 Submit Operating Report for the Month of February 1977 ML19105A3171977-03-10010 March 1977 Submit Monthly Operating Report for the Month of February 1977 ML19095A3141977-02-14014 February 1977 Response to Request, Attached, Revised Pages of Monthly Operating Statistics. as Surry Units Are Base Loaded, Reactor Reserve Shutdown Hours Should Be Zero Rather than That Previously Reported ML19095A3151977-02-11011 February 1977 Submit Operating Report for the Month of January 1977 ML19105A3181976-12-0909 December 1976 Submit Monthly Operating Report for the Month of November 1976 ML19095A3161976-12-0909 December 1976 Submit Operating Report for the Month of November 1976 ML19105A3211976-11-10010 November 1976 Submit Monthly Operating Report for the Month of October 1976 ML19095A3171976-11-10010 November 1976 Submit Operating Report for the Month of October 1976 ML19105A3241976-10-0808 October 1976 Submit Monthly Operating Report for the Month of September 1976 & Corrected Copy of Data for August 1976 ML19095A3181976-10-0808 October 1976 Submit Operating Report for the Month of August 1976 ML19105A3251976-09-13013 September 1976 Submit Monthly Operating Report for the Month of August 1976 on Units 1 & 2, & Corrected Copy of Data for March Through July 1976 on Unit 1 & April Through July 1976 on Unit 2 ML19095A3201976-09-13013 September 1976 Submit Operating Report for the Month of August 1976, & Corrected Copies of Data for Mach Through July 1976 on Unit 1 and April Through July 1976 on Unit 2 ML19095A3231976-08-0202 August 1976 Submit Operating Report for the Month of July, 1976 ML19105A3261976-08-0202 August 1976 Submit Monthly Operating Report for Surry 2 for the Month of July 1976 ML19095A3271976-06-0707 June 1976 Submit Operating Report for the Month of May 1976 & Corrected Copies for April 1976 ML19105A3271976-06-0707 June 1976 Submit Monthly Operating Report for the Month of May 1976 & Corrected Operating Report for the Month of April 1976 ML19095A3301976-05-12012 May 1976 Submit Operating Report for the Month of April 1976 ML19105A3281976-05-12012 May 1976 Submit Monthly Operating Report for Surry 2 for the Month of April 1976 ML19105A3291976-03-0808 March 1976 Submit Monthly Operating Report for Surry 2 for the Month of February 1976 ML19105B1161976-03-0202 March 1976 03/02/1976 Semiannual Operating Report for July 1 Through December 31, 1975, Volume I ML19098B4771975-12-11011 December 1975 Forwarding Two Missing Pages to Be Inserted in Semiannual Operating Report, SOR-6, Covering Period 1/1/1975 Through 6/30/1975 ML19105A3301975-11-14014 November 1975 Submit Monthly Operating Report for the Month of October 1975 & Corrected Operating Report for the Month of September 1975 ML19095A3381975-11-14014 November 1975 Submit Operating Report for the Month of October 1975 & Corrected Copy for Unit 2 for the Month of September 1975 ML19105A3311975-09-0808 September 1975 Submit Monthly Operating Report for the Month of August 1975 ML19095A3421975-09-0808 September 1975 Submit Operating Report for the Month of August 1975 ML19105B1151975-08-29029 August 1975 08/29/1975 Submit Semiannual Operating Report, SOR-6, Covering the Period January 1 Through June 30, 1975 ML19095A3441975-08-0808 August 1975 Submit Operating Report for the Month of July 1975 ML19105A3331975-07-0909 July 1975 Submit Monthly Operating Report for the Month of June 1975 ML19095A3461975-07-0909 July 1975 Submit Operating Report for the Month of June 1975 ML19095A3481975-06-12012 June 1975 Submit Operating Report for the Month of May 1975 ML19105A3351975-05-13013 May 1975 Response to Directive of 2/19/1974 Requiring Operating Information on a Monthly Basis, Submit Monthly Operating Report for the Month of April 1975 ML19095A7531975-05-13013 May 1975 Submit Monthly Operating Report for the Month of April 1975 2022-03-09
[Table view] |
Text
VIRGINIA ELECTRIC AND POWER COMPANY V RICHMOND, VIRGINIA 23261 August 18. 2006 U.S. Nuclear Regulatory Commission Serial No.: 06-648 Attention: Document Control Desk NLOS/vlh: RD Washington, D.C. 20555 Docket No.: 50-280 License No.: DPR-32 VIRGINIA ELECTRIC AND POWER COMPANY (DOMINION)
SURRY POWER STATION UNIT .1 OWNER'S ACTIVITY REPORT As allowed by ASME Code Case N-532-1, "Alternative Requirements to Repair and Replacement Documentation Requirements and Inservice Summary Report Preparation and Submission as Required by IWA-4000 and IWA-6000,Section XI, Division 1," the Form OAR-1 for Surry Unit 1 refueling outage SIR20 is enclosed. This document contains reporting requirements for the first period of the fourth ten-year inservice inspection interval for Surry Unit 1 from December 4, 2004, through the duration of the S1 R20 refueling outage completed on May 27, 2006. The first period ends on October 13, 2006.
Should you have any questions regarding this submittal, please contact Mr. Gary Miller at (804) 273-2771.
Very truly yours, Gerald T. Bischo~f Vice President - Nuclear Engineering
Attachment:
- 1. S1 R20 Owner's Activity Report (Form OAR-i)
Commitments made in this letter: None A-r,,V-
Serial No.06-648 Docket No. 50-280 Page 2 of 2 cc: U.S. Nuclear Regulatory Commission Region II Sam Nunn Atlanta Federal Center 61 Forsyth Street, SW Suite 23 T85 Atlanta, Georgia 30303 Mr. N. P. Garrett NRC Senior Resident Inspector Surry Power Station Mr. S. R. Monarque NRC Project Manager U. S. Nuclear Regulatory Commission One White Flint North 11555 Rockville Pike Mail Stop 8G9A Rockville, MD 20852 Mr. S. P. Lingam NRC Project Manager U. S. Nuclear Regulatory Commission One White Flint North 11555 Rockville Pike Mail Stop 8G9A Rockville, MD 20852 Mr. R. A. Smith Authorized Nuclear Inspector Surry Power Station
Serial No.06-648 Docket No. 50-280 Attachment Owner's Activity Report (Form OAR-i)
Surry Unit I Refueling Outage S1 R20 First Period of the Fourth Ten-Year ISI Interval Virginia Electric and Power Company (Dominion)
SURRY POWER STATION, SI R20 OUTAGE FORM OAR-1 OWNER'S ACTIVITY REPORT Report Number. 1-4-1-2 (Unit 114th IntervalIst1'Pprind 2nd RApnrt)
Owner: Virainia Electric and Power Company. 5000 Dominion Boulevard, Glen Allen, VA 23060 Plant: Surrv Power Station. 5570 Hoo Island Rd. Surry. VA 23883 Unit No. I Commercial service date 12/22/72 Refueling outage no. S1 R20 Current inspection interval Ath Current inspection period Edition and Addenda of Section XI applicable to the inspection plan 1998 Edition through 2000 Addendum Date and revision of inspection plan Surry Unit 1 4eh Interval ISI Plan Revision 3, February 2006 Edition and Addenda of Section XI applicable to repairs and replacements, if different than the inspection plan N/A CERTIFICATE OF CONFORMANCE I certify that the statements made in this Owner's Activity Report are correct, and that the examinations, tests, repairs, replacements, evaluations, and corrective measures represented by this report conform to the requirements of Section XI.
Certificate of Authorization No. N/A Expiration Date N/A Signed j151r?-v. or S $Ow5Pners* 4.169. DateT4?
(Owner's or Owner's Desig nee, Title)
CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Virainia and employed by H.S.B. - CT of Hatford. CT have inspected the items described In this Owner's Activity Report, during the period -124/04 to 5/2706 , and state that to the best of my knowledge and belief, the Owner has performed all activities represented by this report in accordance with the requirements of Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations, tests, repairs. replacements, evaluations and corrective measures described in this report. Furthermore, neither the Inspector nor his employer shall be liable, in any manner for any personal Injury or property damage or loss of any kind arising from or connected with this inspection.
~ ~ 4A ~Commissions VAMII Inspector's Signature National Board, State. Province, and Endorsements Date- C2
Serial No.06-648 Docket No. 50-280 Attachment SURRY POWER STATION SI R20 OUTAGE FORM OAR-1 OWNER'S ACTIVITY REPORT TABLE I ABSTRACT OF EXAMINATIONS AND TESTS Total Total Total Total Examinations Examinations Examinations Examinations Credited (%) To Examination Required for Credited for Credited (%) For Date for The Category The Interval This Period The Period Interval Remarks B-A 10 0.3 3.0% 3.0% Note 6 B-B 5 1.3 26.0% 26.0%
B-D 30 6 20.0% 20.0%
B-G-1 345 88 25.5% 25.5% Note 1 B-G-2 95 7 7.4% 7.4% Note 1 B-K 28 6.3 22.5% 22.5%
B-L-1 1 0 0% 0% Note 6 B-L-2 1 0 0% 0% Note 1 B-M-2 7 1 14.3% 14.3% Note 1 B-N-1 3 1 33.3% 33.3%
B-N-2 1 0 0% 0% Note 6 B-N-3 1 0 0% 0% Note 6 B-O 3 0 0% 0% Note 6 B-P 7 2 28.6% 28.6% Note 2 B-Q 9 2 22.2% 22.2% Note 3 C-A 7 1.7 24.3% 24.3%
C-B 15 3.3 22.0% 22.0%
C-C 16 4 25.0% 25.0%
C-G 36 0 0% 0% Note 4 C-H 3 0 0% 0% Note 5 D-A 51 12 23.5% 23.5%
D-B 3 0 0% 0% Note 5 F-A 277 71 25.6% 25.6%
R-A 136 48 35.3% 35.3%
Note 1: Many exams presently scheduled are required only ifcomponent is disassembled for maintenance.
Total examinations and percentages required may change according to maintenance activities.
Note 2: The Class 1 leakage test is required to be performed every refueling outage. The numbers and percentages represent the total number of refueling outages planned for the 4th Interval. The reactor coolant system VT-2 exam, 1-PT-11, was performed on May 23, 2006.
Note 3: Total examinations required may change dependent on the S/G Eddy Current Program.
Serial No.06-648 Docket No. 50-280 Attachment Note 4: Total examinations required will be determined by maintenance performed on any C-G pump.
Exams are required only when a pump is disassembled for maintenance.
Note 5: The numbers and percentages represent the total number of periods over the inspection interval. All 1st Period Class 2 and 3 System Pressure Tests are scheduled for completion by the end of the 1st Period, October 13, 2006.
Note 6: Deferral is permissable.
Serial No.06-648 Docket No. 50-280 Attachment SURRY POWER STATION SIR20 OUTAGE FORM OAR-1 OWNER'S ACTIVITY REPORT TABLE 2 ITEMS WITH FLAWS OR RELEVANT CONDITIONS THAT REQUIRE EVALUATION FOR CONTINUED SERVICE Flaw or Relevant Condition Found During Scheduled Exam Item Flaw Characterization Section X) Exam or Category Number Item Description (IWA-3300) Test (Yes or No)
F-A F1.30 1-WCMU-H008 Loosened pipe clamp components Yes, Support B-G-2 B7.70 1-SI-147 Thread damage Yes 2 Bolting Notes:
I Scope expanded to cover additional supports; all additional inspections were satisfactory.
2 Damage occurred by wrench during maintenance activity, not a service induced flaw. Evaluated satisfactory as found.
No scope expansion required.