Gregory H. Halnon General Manager, Nuclear Plant Operations 803.345.4007 A SCANA COMPANY April 28, 2003 Document Control Desk U.-S.Nuclear Regulatory Commission Washington, DC 20555
Dear Sir/Madam:
Subject:
VIRGIL C. SUMMER NUCLEAR STATION DOCKET NO. 50-395 OPERATING LICENSE NO. NPF-12 ANNUAL EFFLUENT AND WASTE DISPOSAL REPORT Enclosed is the South Carolina Electric & Gas Company (SCE&G) Annual Effluent and Waste Disposal Report as required by 10CFR50.36a, Sections 6.9.18 and 6.14.2 of the Virgil C. Summer Nuclear Station Technical Specifications, and Section 1.6.2 of the Offsite Dose Calculation Manual (ODCM). This submittal covers the period of January 1through December 31, 2002.
Should there be any questions, please contact us at your convenience.
SBR/GHH/sr Enclosure c: N. 0. Lorick NRC Resident Inspector N.S. Cams T. P. O'Kelley (SCDHEC)
T. G. Eppink (w/o enclosure) M. Coleman (402)
R.J. White (w/o enclosure) J. A. Orr (P40)
L.A. Reyes NSRC K. R. Cotton RTS (0-L-99-0113)
W. G.Wendland File (818.02-1, RR 8350)
K. M. Sutton DMS (RC-03-0090)
.7,-ti q%
s tiG I Virgil CSummer Nudear Station
- P.0.Box 88 . Jenkinsville, South Carolino 29065 -T(803) 345.5209 .wwwmsanaom
I ' VIRGIL C. SUMMER JENKINSVILLE, SOUTH CAROLINA ANNUAL EFFLUENT AND WASTE DISPOSAL REPORT VIRGIL C. SUMMER NUCLEAR STATION FOR THE OPERATING PERIOD JANUARY 1, 2002 - DECEMBER 31, 2002 APRIL 2003 A SCANA COMPANY Prepared by:
%N\~CJ__
Moses Coleman, Health Physicist Reviewed by: Approved G.M.Gb~dy, Health hysicist .A. Blue, Manager Health Physics Services
ANNUAL EFFLUENT AND WASTE DISPOSAL REPORT JANUARY - DECEMBER, 2002 VIRGIL C. SUMMER NUCLEAR STATION SOUTH CAROLINA ELECTRIC & GAS This report is being submitted as a summary of quantities of radioactive liquid and gaseous effluents and solid waste released from the Virgil C. Summer Nuclear Station. This report satisfies the requirements in Sections 6.9.1.8 and 6.14.2 of Technical Specifications, Section 1.6.2 of the Offsite Dose Calculation Manual (ODCM), and 10CFR50.36(a). Also included is an assessment of radiation doses from plant releases.
A brief discussion of the Supplemental Information and Tables I through 5 is presented in Sections A through D. An evaluation of the radiological impact on man due to operation of the Virgil C. Summer Nuclear Station is presented in Section E and Table 6. There were no abnormal releases for the period. A summary of the meteorological data for 2002 is presented in Section G and Tables 7 and 8. There were no changes made to the Offsite Dose Calculation Manual (ODCM) during the 12-month period.Section I gives a summary of oil incineration during the year.
A. Supplemental Information Regulatory limits for doses, dose rate and effluent concentration limits presented in Supplemental Information are from the Virgil C. Summer Nuclear Station ODCM and 40 CFR 190. Average energy (E5 is not applicable to the method for determining release rate limits for fission and activation gaseous effluents; therefore, it has been omitted.
B. Gaseous Effluents Gaseous effluents released from ground level are summarized in Tables I and 2. An elevated release pathway does not exist at Virgil C. Summer Nuclear Station. Cumulative doses are discussed in Section E.
The errors for gaseous effluent totals are given as the square root of the sum of squares of counting errors and flow or volume measurement errors. A systematic error of 15% has been added to estimate total error.
PAGE 1
ANNUAL EFFLUENT AND WASTE DISPOSAL REPORT JANUARY - DECEMBER, 2002 VIRGIL C. SUMMER NUCLEAR STATION SOUTH CAROLINA ELECTRIC & GAS C. Liquid Effluents Liquid effluents are summarized inTables 3 and 4. Estimated total errors are expressed as in Section B above.
D. Solid Waste Shipments Solid waste shipments are summarized in Table 5. Curie content of radioactive waste packages is determined by dose rates and/or gamma spectroscopy analysis of samples. The total error for each type of Curie content determination is conservatively estimated to be the sum of a 15% systematic error and a 20% photon response error for the detector used.
E. Radiological Impact on Man Potential doses to the maximum exposed individual in the unrestricted area were calculated using measured plant gaseous effluents and meteorological data in accordance with the Offsite Dose Calculation Manual. The source term involved two (2)waste gas decay tank (WGDT) releases, 0.9 days of 6-inch Reactor Building purge releases, 15.9 days of 36-inch Reactor Building purge releases and a continuous 12-month Main Plant vent release. Oil incineration was run for 37.9 hours1.041667e-4 days <br />0.0025 hours <br />1.488095e-5 weeks <br />3.4245e-6 months <br /> in 2002. Doses are summarized in Table 6. The total activities released are presented in Tables 1 and 2. The highest quarterly air doses to the maximum exposed individual due to noble gases were 1.65E-05 and 1.32E-5 mrad for gamma and beta, respectively, during the second quarter. The maximum quarterly organ dose attributed to the releases was 1.04E-03 mrem for the second quarter. Cumulative annual dose was 2.68E-5 mrad, 1.72E-5 mrad and 1.04E-3 mrem for gamma, beta, and organ dose, respectively.
Measured plant liquid effluent data was used to calculate estimates of doses to individuals in accordance with the Offsite Dose Calculation Manual. The source term consisted of the isotopic contents of 315 Waste Monitor Tank batch releases, 17 Condensate Backwash Receiver Tank batch releases, 1 NaOH batch releases, 16.7 days of Steam Generator Blowdown release and a continuous Turbine Building Sump release.
PAGE 2
ANNUAL EFFLUENT AND WASTE DISPOSAL REPORT JANUARY - DECEMBER, 2002 VIRGIL C. SUMMER NUCLEAR STATION SOUTH CAROLINA ELECTRIC & GAS Doses are summarized in Table 6 and total radioactivity released is described in Tables 3 and 4. The highest quarterly total body dose to the maximally exposed individual due to the release of radioactive liquid was 2.16E-3 mrem during the first quarter. The highest organ dose was 2.31 E-3 mrem to the Liver for the first quarter. Cumulative annual doses for the hypothetical maximally exposed individual were 4.04E-3 mrem for the total body and 4.24E-3 mrem for the maximum annual organ (liver). The Liver was the maximum exposed organ for the first and fourth quarters and the GI-LLI for the second and third quarters.
Dose rates and concentrations were below the limits specified in Supplemental Information, Section 2a, b and c during all the effluent releases.
Radiation doses from radioactive effluents to members of the public due to their activities inside the site boundary were assessed in a manner different from that in the Offsite Dose Calculation Manual.
Quarterly thermoluminescent dosimetry data from four (4) monitoring locations within the site boundary and eight (8) locations around the site boundary perimeter were analyzed and compared with respective pre-operational background and previous year history. Results showed that 2002 quarterly dose rates did not differ significantly from the pre-operational or 2001 dose rates. It was concluded that doses to members of the public inside the site boundary were indistinguishable from normal background dose.
Radiation doses from radioactive effluents to workers at the Fairfield Hydro Station for the 12-month period were calculated to be 1.26E-6 and 8.09E-7 mrad for gamma and beta, respectively.
Radiation doses from nearby uranium fuel cycle sources were not assessed. The ODCM, Sections 1.3.1 and B/1.3 establish a five (5) mile limit beyond which doses from nearby plants are insignificant. There are no uranium fuel cycle plants within a five (5) mile radius of Virgil C. Summer Nuclear Station.
PAGE 3
ANNUAL EFFLUENT AND WASTE DISPOSAL REPORT JANUARY - DECEMBER, 2002 VIRGIL C. SUMMER NUCLEAR STATION SOUTH CAROLINA ELECTRIC & GAS F. Abnormal Releases During 2002, the plant had no abnormal releases.
G. Meteorology The meteorology data for 2002 is summarized in Table 7, by quarter. The data are shown as joint frequency distributions of wind direction and speed by atmospheric stability class.
The wind direction and wind speed data used in the summary were acquired from the 10-meter level of the primary monitoring tower. Stability was determined by the primary differential temperature (61 to 10 meter).
The combined annual data recovery for wind direction, wind speed and stability was 83.2%. Primary variable recovery rates were as follows: wind direction (10 m) - 83.2%, wind speed (10 m) -
94.9%, and differential temperature (61 - 10 m) - 96.1%.
H. Offsite Dose Calculation Manual The Virgil C. Summer Nuclear Station (VCSNS) Offsite Dose Calculation Manual (ODCM) was not revised during the affected 12-month period.
I. Oil Incineration The incinerator operated for a period of 37.9 hours1.041667e-4 days <br />0.0025 hours <br />1.488095e-5 weeks <br />3.4245e-6 months <br />, burning 368 gallons of oil at 9.7 gal/hr. The incinerated oil contained concentrations of 2.38E-06 uCi/ml Co-60, 6.52E-09 uCi/mI Mn-54, 1.1 3E-06 uCi/ml Fe-55, and 2.33E-07 uCVml Cs-1 37. The dose to the maximum exposed individual from the incinerated oil was 3.88E-05 mrem.
PAGE 4
ANNUAL EFFLUENT AND WASTE DISPOSAL REPORT JANUARY- DECEMBER, 2002 VIRGIL C. SUMMER NUCLEAR STATION SOUTH CAROLINA ELECTRIC & GAS during troubleshooting to determine the cause of intermittent spiking events with the monitor. An improper resistor in the monitor's rate meter module and channel crossover interference from other modules in the same rack contributed the overall problem and required an extensive amount of trouble shooting and research to resolve. There were no effluents released from this pathway during the out of service period.
SUPPLEMENTAL INFORMATION Regulatory Limits:
- a. Fission and Activation Gases:
The air dose to an individual due to noble gases released in gaseous effluents shall be limited to less than or equal to 5 mrad for gamma radiation and 10 mrad for beta radiation during any calendar quarter and 10 mrad for gamma radiation and 20 mrad for beta radiation during any calendar year (ODCM, Section 1.2.3.1).
- b. lodines, Particulates (half-lives > 8 days) and Tritium:
The dose to an individual from radioiodines, tritium and radioactive materials in particulate form with half-lives greater than 8 days in gaseous effluents shall be limited to less than or equal to 7.5 mrem to any organ during any calendar quarter and 15 mrem to any organ during any calendar year (ODCM, Section 1.2.4.1).
- c. Liquid Effluents:
The dose or dose commitment to an individual from radioactive materials in liquid effluents released shall be limited to less than or equal to 1.5 mrem to the total body and 5 mrem to any organ during any calendar quarter and 3 mrem to the total body and 10 mrem to any organ during any calendar year (ODCM, Section 1.1.3.1).
- d. All Sources:
The annual dose equivalent shall not exceed 25 mrem to the whole body, 75 mrem to the thyroid and 25 mrem to any other organ (40 CFR 190).
PAGE 5
ANNUAL EFFLUENT AND WASTE DISPOSAL REPORT JANUARY - DECEMBER, 2002 VIRGIL C. SUMMER NUCLEAR STATION SOUTH CAROLINA ELECTRIC & GAS
- d. All Sources:
The annual dose equivalent shall not exceed 25 mrem to the whole body, 75 mrem to the thyroid and 25 mrem to any other organ (40 CFR 190).
- 2. Dose Rate and Effluent Concentration Limits:
- a. Fission and Activation Gases The dose rate in unrestricted areas due to radioactive materials released in gaseous effluents shall be limited to less than or equal to 500 mrem/year to the total body and less than or equal to 3000 mrem/yearto the skin (ODCM, Section 1.2.2.1).
- b. lodines, Particulates (half-lives > 8 days) and Tritium:
The dose rate in unrestricted areas due to radioactive materials in effluents shall be limited to less than or equal to 1500 mrem/year to any organ (ODCM, Section 1.2.2.1).
- c. Liquid Effluents:
The concentration of radioactive materials released from the site shall be limited to the concentrations specified in 10 CFR 20, Appendix B, Table 2, Column 2 for radionuclides other than dissolved or entrained noble gases. For dissolved or entrained noble gases, the concentration shall be limited to 2E-4 pCi/ml total activity (ODCM, Section 1.1.2.1).
- 3. Average Energy:
Not Applicable
- 4. Measurements and Approximations of Total Radioactivity:
- a. Fission and activation gases: Gamma spectrometry (HPGe)
- b. lodines: Gamma spectrometry (HPGe)
- c. Particulates: Gamma spectrometry (HPGe), beta proportional counting, alpha proportional counting PAGE 6
ANNUAL EFFLUENT AND WASTE DISPOSAL REPORT JANUARY - DECEMBER, 2002 VIRGIL C. SUMMER NUCLEAR STATION SOUTH CAROLINA ELECTRIC & GAS
- d. Tritium: Liquid scintillation
- e. Liquid effluents: Gamma spectrometry (HPGe), liquid scintillation (H-3), beta proportional counting, alpha proportional counting
- 5. Batch Releases:
- a. Gaseous:
- 1. Number of batch releases: 2
- 2. Total time period for batch releases: 406 min
- 3. Maximum time period for a batch release: 343 min
- 4. Average time period for a batch release: 203 min
- 5. Minimum time period for a batch release: 63 min
- b. Liquid:
- 1. Number of batch releases:
140 For first quarter, 2002 111 For second quarter, 2002 45 For third quarter, 2002 37 For fourth quarter, 2002
- 2. Total time period for batch releases:
1.1 2E+4 min. for first quarter, 2002 8.65E+3 min. for second quarter, 2002 3.63E+3 min. for third quarter, 2002 2.92E+3 min. for fourth quarter 2002 PAGE 7
ANNUAL EFFLUENT AND WASTE DISPOSAL REPORT JANUARY - DECEMBER, 2002 VIRGIL C. SUMMER NUCLEAR STATION SOUTH CAROLINA ELECTRIC & GAS
- 3. Maximum time period for a batch release:
9.50E+1 min. for first quarter, 2002 9.50E+1 min. for second quarter, 2002 1.OOE+2 min. for third quarter, 2002 8.40E+1 min. for fourth quarter, 2002
- 4. Average time period for batch releases:
7.98E+1 min. for first quarter, 2002 7.80E+1 min. for second quarter, 2002 8.06E+1 min. for third quarter, 2002 7.88E+1 min. for fourth quarter, 2002
- 5. Minimum time period for a batch release:
5.20E+1 min. for first quarter, 2002 2.10E+1 min. for second quarter, 2002 1.OOE+0 min. for third quarter, 2002 7.30E+1 min. for fourth quarter, 2002
- 6. Average stream flow during periods of release of effluent into a flowing stream for 2002:
5.44E+6 gpm for first quarter, 2002 5.77E+6 gpm for second quarter, 2002 1.03E+7 gpm for third quarter, 2002 6.11 E+6 gpm for fourth quarter, 2002
- 6. Abnormal Releases:
- a. Gaseous:
- 1. Number of releases: 0
- 2. Total activity released: 0
- b. Liquid:
- 1. Number of releases: 0
- 2. Total activity released: 0 PAGE 8
ANNUAL EFFLUENT AND WASTE DISPOSAL REPORT January - December 2002 Virgil C. Summer Nuclear Station South Carolina Electric & Gas Table I Gaseous Effluents Summation of All Releases
- . . Y ----- N - ..- - -
UNITS FIRST StUUNU I HIKR F-UUKIR I zuuz .b I .
______________________________________________ a .
QUARTER I QUARTER S QUARTER I QUARTER I TOTAL S ERROR %
l A. Fission & Activation Gases
- 1. Total release Ci 6.66E-03 4.74E-02 0.OOE+00 2.76E-04 5.43E-02 26.28
- 2. Average release rate uCi / sec 8.57E-04 6.02E-03 0.OOE+00 3.47E-05 1.72E-03
- 3. Percent ODCM Qtr. gamma air dose limit 2.07E-04 3.29E-04 O.OOE+00 1.13E-07 N/A
- 4. Percent ODCM annual gamma air dose limit 1.03E-04 2.68E-04
- 2.68E-04
- 2.68E-04
- 2.68E-04
- 5. Percent ODCM Qtr. beta air dose limit 3.89E-05 1.32E-04 0.OOE+00 9.47E-07 N/A
- 6. Percent ODCM annual beta air dose limit 1.95E-05 8.55E-05
- 8.55E-05
- 8.60E-05
- 8.60E-05 B. lodines 1.Total iodine- 131 Ci O.OOE+00 2.26E-06 O.OOE+00 O.00E+00 2.26E-06 80.75
- 2. Average release uCi I sec O.OOE+00 2.88E-07 0.OOE+00 0.OOE+00 7.16E-08 C. Particulates
- 1. Particulates with half - lifes > 8 days Ci 0.OOE+00 2.64E-07 O.OOE+00 0.OOE+00 2.64E-07 78.50
- 2. Average release rate uCi / sec 0.OOE+00 3.36E-08 0.OOE+00 O.OOE+00 8.37E-09
- 3. Gross alpha radioactivity Ci O.OOE+00 O.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 D. Tritium
- 1. Total release Ci 5.91 E-04 1.89E+00 O.OOE+00 O.OOE+00 1.89E+00 49.08
- 2. Average release rate uCi / sec 7.60E-05 2.40E-01 O.OOE+00 0.OOE+00 5.99E-02 E. Organ Dose (from B,C,and D)
- 1. Percent ODCM Qtr. organ dose limit 4.15E-06 1.38E-02 O.OOE+00 O.OOE+00 N/A
- 2. Percent ODCM annual organ dose limit _ .
2.08E-06 _
6.92E-03 .
6.92E-03 6.92E-03
- _
6.92E-03
- Cumulative
I ANNUAL EFFLUENT AND WASTE DISPOSAL REPORT JANUARY - DECEMBER, 2002 TABLE 2 GASEOUS EFFLUENTS - GROUND-LEVEL RELEASES Iinffn4une Mnde Batch Mode Nuclides Released Units First Second Third Fourth Annual First Second Third Fourth Annual QatrlQatr Quarter Quarter Total Quarter -Quarter Quarter Quarter TotTall 1 Fission gases Krypton-85 Ci 0 0 0 0 0 2.05E-04 0 0 2.05E-04 4.10E-04 Krypton-85m Ci 0 0 0 0 0 0 0 0 0 0 Krypton-87 Ci 0 0 0 0 0 0 0 0 0 0 Krypton-88 Ci 0 0 0 0 0 0 0 0 0 0 Xenon-133 Ci 932E-04 4.OOE-02 0 4.09E-02 0 0 0 7.03E-05 7.03E-05 Xenon-135 Cl 0 0 0 0 0 0 0 0 0 0 Xenon-135m Ci 0 0 0 0 0 0 0 0 0 0 Xenon-138 Cl 0 0 0 0 0 0 0 0 0 0 Other: Ar-41 Ci 5.52E-03 7.35E-03 0 0 1.29E-02 0 0 0 0 0 Unidentified: None Ci 0 0 0 0 0 0 0 0 0 0 Total for Period Ci 6.46E-03 4.74E-02 0 0 5.38E-02 2.05E-04 0 0 2.76E-04 4.80E-04 2 lodines and other halogens Iodine-131 Cil 0 2.26E-06 0 0 2.26E-06 0 0 0 0 0 Iodine-132 Ci 0 1.62E-05 0 0 1.62E-05 0 0 0 0 0 Iodine-133 Cl 0 0 0 0 0 0 0 0 0 0 Br-82 Ci 0 8.77E-08 0 0 8.77E-08 0 0 0 0 0 Unidentified: None Ci 0 0 0 0 0 l 0 0 0 0 0 Total for Period Ci 0 1.86E-05 0 0 1.86E-05 0 0 0 0 0 3 Particulates Cl 0 0 0 0 0 0 0 0 0 0 Cromiun-51 Cobalt-58 Ci 0 7.63E-08 0 0 7.63E-08 0 0 0 0 0 Cobalt-60 Ci 0 0 0 0 0 0 0 0 0 0 Stronium-89 Ci 0 0 0 0 0 0 0 0 0 0 Stronium-90 Ci 0 0 0 0 0 0 0 0 0 0 Nioblum-95 Ci 0 0 0 0 0 0 0 0 0 0 Cl 0 0 0 0 0 0 0 0 0 0 Cesium-134 Ci 0 0 0 0 0 0 0 0 0 0 Ceslum-137 Other: Os-191 Cl 0 1.88E-07 0 0 1.88E-07 0 0 0 0 0 Unidentified: None Ci 0 0 0 0 0 0 0 0 0 0 Total for Period Ci 0 2.64E-07 0 0 2.64E-07 0 0 0 0 0
I ANNUAL EFFLUENT AND WASTE DISPOSAL REPORT JANUARY-DECEMBER, 2002 Virgil C. Summer Nuclear Station South Carolina Electric & Gas TABLE 3 Liquid Effluents Summation of All Releases HT I
- bt TNU I HIRU FIUUflRI002 hb 1.
UNITS QUARTER QUARTER QUARTER QUARTER TOTAL ERROR %
A. Fission & Activation Products
- 1. Total release Cl 2.80E-02 1.46E-02 4.74E-03 3.93E-03 5.12E-02 56.00
- 2. Average diluted concentration uCI/mi 6.94E-11 3.88E-11 1.18E-11 1.19E-11 3.39E-11 B. Tritium
- 1. Total release Cl 1.59E+02 1.41E+02 3.71 E+01 5.57E+00 3.42E+02 18.46
- 2. Average diluted concentration uCi/ml 3.93E-07 3.74E-07 9.25E-08 1.69E-08 2.26E-07 C. Dissolved and entrained gases
- 1. Total release Ci 1.1 E-03 2.12E-03 3.29E-04 0.OOE+00 3.56E-03 23.96
- 2. Average diluted concentration uCI/ml 2.76E-12 5.65E-12 8.20E-13 O.OOE+00 2.36E-12 3.Percent ODCM limit % 1.38E-06 2.82E-06 4.1 OE-07 0.OOE+00 1.18E-06 D. Gross alpha radioactivity
- 1. Total release Ci 0 0 0 0 0 N/A E. ODCM limits (from A and B)
- 1. Percent of ODCM Qtr total body limit % 1.44E-01 1.11 E-01 1.05E-02 4.31 E-03 N/A
- 2. Percent of ODCM annual total body limit 7.19E-02 1.27E-01
- 1.33E-01
- 1.35E-01
- 1.35E-01 *
- 3. Percent of ODCM Qtr max. organ limitK' % 4.62E-02 3.58E-02 3.41 E-03 1.44E-03 N/A
- 4. Percent of ODCM annual max. organ llmit* % 2.31 E-02 4.10E-02 4.27E-02
- 4.34E-02
- 4.34E-02
- liters 1.15E+07 4.02E+07 9.19E+06 1.08E+07 7.17E+07 3.0 E. Volume of waste released (undiluted) lIters 4.04E+11 3.76E+11 4.01 E+11 3.30E+11 1.51E+12 4.3 F. Volume of dilution water
- Cumulative
- See page 3 for max. organ for each quarter and cumulative.
ANNUAL EFFLUENT AND WASTE DISPOSAL REPORT JANUARY - DECEMBER, 2002 Wrgil C.Summer Nuclear Station South Carolina Electric & Gas TABLE 4 LIQUID EFFLUENTS Coutinuoms Mode Batch Mode I
Nuelides Reles Units I
I First Quarter I Second Quarter I Third Quarter I Fourth Quarter I Annual Total I kirt a -A 5Thi lrd Quarter Intro Quarter Fourth Quarter Annual Total Strontlumt-89 Li 0 j 0 0 j 0 0 a 0 j 0 0 0 J Stranptlm- l0 0 0 0 0 0 0 1.46E-C6 3.19E-06 137E-C6 6.02E-CE Cesium-134 a e 0 0 0 0 1.52K-CE 0 0 0 1.52E-C6 Ceslust-137 0 0 0 e0 0 5.68E-C4 1.58E-04 1.45K-CU 3.70E-C 7.63E-C4 iodine __31 _ _ 0 j 0 0 0 0 0 0 0 0 0 Cobalt-SS a e 0 0 0 0 5.62E-04 1.17E-03 3.64E-04 5.26E-04 2.62E-03 Cobalt-6e a e 0 e 0 0 1.03E-02 2.36E4e3 3.s3E-04 4.10E-04 1.35E-02 Iron-59 a o 0 0 0 0 0 3.65K-O5 1.23K-CE 0 3.77E-CS sC ait o 0 0 0 0 0 0 0 1.04K-CS 1.04K-CS Manpnese-54 a 0 0 0 0 0 13ff03 3.01E-04 4.21E-CS 6.49E-SI 1.77E-03 Chromlunt-S1 a1 o 0 0 0 0 0 7.32E-04 7.39K-CS - 8.0EK-04 Zireenivin-Nlobunat-95 a1 o 0 0 0 0 4.34K-CE 1.14E-04 1.37K-CS 0 1.37E-04 Mo enum-99 Cl 0 e0 0 0 0 0 0 a 0 Technetiuni-99m a1 - S 0 0 0 0 0 0 0 0 0 BRawm-Lanthinum-140 aC 0 0 0 0 0 0 0 0 0 0 Cerivm-141 (1 0 0 0 0 0 0 e 0 0 0 Other: Ns-24 0 0 0 0 0 0 0 0 0 0 Fe-55 a 0 0 0 0 0 1.SE-02 5s9E-03 3.70E-03 2.70E-03 3.OOE-02 Ce-57 a 0 0 0 0 0 333E-0S 2.15E-07 0 5.66E-06 3.92E-KS Br-82 a o 0 0 0 0 5.97EK-6 4.12E-C6 0 0 1.01eE-S Ag-116m a 0 0 0 0 0 .1SE-CS 3.95E-e6 6.99E-C6 7.57E-CE 3.03E-05 Sn-113 a o 0 0 0 0 0 1.54E-E6 0 5.27E-07 2.07E-C6 Sn-117m a 0 0 0 0 0 1.72E-C5 3.32E-e6 a 2.05E-Cs Sb-124 a 0 0 0 0 0 0 5.90E-E6 0 0 5.90E-C6 Sb-125 a e 0 0 0 0 132E-04 2.33E-CS 2.40E-CS r .76E-C5 2.67E-04 Te-125m a 0 0 0 a 0 1.03E-C3 1.23E-04 7.78E-CS 1.23E-03 1-133 Co 0 0 0 0 j 0 0 1.17E-66 0 1.17E-CE Unidentifled: None a 0 0 a0 0 0 0 0 0e Total for Period (above) a I 0 0 0 0 2.8OE-C2 1.45E-02 4.74K-C3 3.93E-03 5.12E-02 Xnon-133 C1 ~ 0 0 0 0 0 1.11E-C3 1.96F-C3 3.2OE-C4 0 3.39K-C3 Xeon-135 a - 0 0 0 0 1.20K-CE 1.01K-CS 9.07K-C6 0 2.04E-05 Other: Ar-41 a e 0 _ 0 0 0 0 0 1.74E-06 0 0 1.74K-CE Kr-8S a1 a __ 0 0 0 0 0 1.41E-04 0 0 1.41E-04 Xe-131_ a _ 0 0 0 0 0 0 0 0 0 Xe-133m a 0e 0 0 0 0 0 7.22K-C6 0 0 7.22E-C6 Wndentifled: Noe a i 0 0 0 0 0 0 0 0 0 ITotal EntrainedG I CI - e0 0 0 0 e .I1K-3 L12K-03 3.2aK-04 e0 3.SEE-C3
.. ' *A . :..... - ituittem not Included. See able 3 or trinum numbers
ANNUAL EFFLUENT AND WASTE DiSPlSAL REPORT January - December, 2002 Virgil C. Summer NuclearStation South Carolina Electric & Gas Table 5 SOLID WASTE AND IRRADIATED FUEL SHIPMENTS A. Solid Waste Shipped Offsite for Burial or Disposal (Not irradiated fuel).
1 Type of Waste Unit 2002 Est. Total
_____________________________________ Total Error, %
- a. Spent resins, filter sludges, m3 9.12 3.5E+01 evaporator bottoms, etc. Ci 48.82
- b. Dry compressible waste m3 10.05 3.5E+01 contaminated equip., etc. Ci 3.98
- c. Irradiated components, m3 0 control rods, etc. Ci 0 N/A
- d. Other (describe) m3 0
_ __ __ _ _ _ _ _ _ _ _Ci 0 N/A
- 2. Estimate of major nuclide composition for the year (by type of waste) for concentrations above 1.0% (listed in descending order by activity level).
a.
Ni-63 % 79.15 Co-60 % 12.11 Fe-55 % 5.50 Ni-59 % 1.00
- c. None N/A
- d. None % N/A 3A. Solid waste Disposition Numbers of Shipments Mode of Transportation Destination 3 Truck Clive, Ut 37* Truck Clive. Ut 2 Truck Barnwell S.C.
- Note: 37 are partial shipments of DAW from waste processor to Clive,Ut.
3B. Irradiated Fuel Shipments (Disposition)
I Number of Shipments Mode of Transportation estination I0 N/A I NWAI
ANNUAL EFFLUENT AND WASTE DISPOSAL REPORT JANUARY -DECEMBER 2002 Virgil C. Summer Nuclear Station South Carolina Electric & Gas Table 6 GASEOUS AND LIQUID DOSES FIRST QUARTER SECOND QUARTER THIRD QUARTER FOURTH QUARTER TOTAL Percent Percent Percent Percent ANNUAL ODCM of Limit DOSE DOSE of Limit DOSE of Limit DOSE of Limit DOSE Section GASEOUS LIMITS 5 mrad gamma / qtr. 1.03E-05 mrad 2.07E-04 1.65E-05 mrad 3.29E-04 0.OOE+00 mrad 0.OOE+00 5.66E-09 mrad 1.13E-07 2.68E-05 1.2.3.1.a,b 10 mrad gamma/ yr. 1.03E-04 2.68E-04
- 2.68E-04 ^ 2.68E-04
- 3.89E-06 mrad 3.89E-05 1.32E-05 mrad 1.32E-04 O.OOE+00 mrad 0.OOE+00 9.47E-08 mrad 9.47E-07 1.72E-05 1.2.3.1.a,b 10 mrad beta/ qtr.
1.95E-05 8.55E-05
- 8.55E-05
- 8.60E-05
- 20 mrad beta / yr.
3.11E-07 mrem** 4.15E-06 1.04E-03 mrem** 1.38E-02 0.OOE+00 mrem* 0.OOE+00 0.OOE+00 mrem** O.OOE+00 1.04E-03 1.2.4.1.a,b 7.5 mrem organ/qtr 2.08E-06 6.92E-03
- 6.92E-03
- 6.92E-03
- 15 mrem organ/yr.
LIQUID LIMITS 2.16E-03 mrem 1.44E-01 1.66E-03 mrem 1.11E-01 1.57E-04 mrem 1.05E-02 6.46E-05 mrem 4.31E-03 4.05E-03 1.1.3.1ab 1.5 mrem/qtr.
7.19E-03 1.27E-01
- 1.33E-01
- 1.35E-01
- 3 mrem /yr.
2.31E-03 mrem 4.62E-02 1.79E-03 mrem 3.58E-02 1.71E-04 mrem 3.41E-03 7.21E-05 mrem 1.44E-03 4.34E-03 1.1.3.1a,b 5 mrem organ/qtr*
2.31E-02 4.10E-02
- 4.27E-02
- 4.34E-02
- 10 mrem organ/yr.
- Includes contribution from previous quarters
- Includes dose from all nuciides
- See page 3 for max organ for each quarter
TABLE 7 JOINT FREQUENCY DISTRIBUTION BY QUARTER FOR 2002
JOINT WIND FREQUENCY DISTRIBUTION BY STABILITY CLASS SITE: V. C. SUMMER Nuclear Station UNIT 1 Report Date : 03-02-26 Data Period : 2 1 00:00 to 2- 3-31 23:00 Stability Class: A delta T/ delta z 61->10 m Delta T With Substitution Wind Sensor Height : 10 meter Hours at Each Wind Direction and Speed Wind Wind Speed (miles/hour)
Direction Mean 0.75- <4 4- <8 8- <13 13- <19 19- 24 >24 Total' Speed N 1 0 0 0 0 0 1 2.70 NNE 1 4 0 0 0 0 5 4.14 NE 1 4 0 0 0 0 5 4.83 ENE 0 3 0 0 0 0 3 5.15 E 0 1 0 0 0 0 1 7.86 ESE 0 1 0 0 0 0 1 6.56 SE 0 0 1 0 0 0 1 8.19 SSE 0 0 0 0 0 0 0 0.00 S 1 1 0 0 0 0 2 4.84 SSW 0 7 2 0 0 0 9 6.38 SW 1 14 4 0 0 0 19 7.09 WSW 1 8 8 2 0 0 19 8.40 W 0 7 2 0 0 0 9 7.28 WNW 0 3 11 1 0 0 15 10.10 NW 0 2 3 0 0 0 5 9.19 NNW 3 3 0 0 0 0 6 4.06 Total 9 58 31 3 0 0 101 Hours of Calm : 0 Hours of Varying Wind Direction 0 Hours of Missing Data : 0 Hours of Missing Data for All : 5 Hours of No Stability Class : 0 Total hours of observation 2160 TABLE 7 FIRST QUARTER 2002 PAGE 1 OF 8
JOINT WIND FREQUENCY DISTRIBUTION BY STABILITY CLASS SITE: V. C. SUMMER Nuclear Station UNIT 1 Report Date 03-02-26 Data Period 2 1 00:00 to 2- 3-31 23:00 Stability Class: B delta T/ delta z 61->10 m Delta T With Substitution Wind Sensor Height : 10 meter Hours at Each Wind Direction and Speed Wind Wind Speed (miles/hour)
Direction Mean 0.75- <4 4- <8 8- <13 13- <19 19- 24 >24 Total' Speed N 1 0 0 1 2 0 4 15.47 NNE 0 3 1 0 3 0 7 13.42 NE 0 2 1 0 0 0 3 7.48 ENE 0 3 0 0 0 0 3 5.81 E 0 2 1 0 0 0 3 7.42 ESE 0 1 1 0 0 0 2 8.14 SE 0 4 1 0 0 0 5 7.06 SSE 0 0 0 0 0 0 0 0.00 S 0 2 1 0 0 0 3 6.45 SSW 1 2 8 0 0 0 11 7.63 SW 3 3 6 1 0 0 13 7.38 WSW 2 5 3 0 0 0 10 6.08 W 2 4 8 0 0 0 14 7.84 WNW 1 1 9 1 0 0 12 9.88 NW 0 1 3 2 0 0 6 10.43 NNW 3 2 3 2 1 A 11 9.75 Total 13 35 46 7 6 0 107 Hours of Calm : 0 Hours of Varying Wind Direction : 0 Hours of Missing Data : 0 Hours of Missing Data for All 5 Hours of No Stability Class : 0 Total hours of observation : 2160 TABLE 7 FIRST QUARTER 2002 PAGE 20F8
JOINT WIND FREQUENCY DISTRIBUTION BY STABILITY CLASS SITE: V. C. SUMMER Nuclear Station UNIT 1 Report Date : 03-02-26 Data Period : 2 1 00:00 to 2- 3-31 23:00 Stability Class: C delta T/ delta z 61->10 m Delta T With Substitution Wind Sensor Height : 10 meter Hours at Each Wind Direction and Speed Wind Wind Speed (miles/hour)
Direction Mean 0.75- <4 4- <8 8- <13 13- <19 19- 24 >24 Total' Speed N 1 5 0 1 0 0 7 6.90 NNE 2 4 3 12 4 0 25 13.82 NE 0 3 9 5 0 0 17 11.48 ENE 0 2 2 0 0 0 4 8.21 E 0 4 5 0 0 0 9 7.73 ESE 0 0 1 0 0 0 1 9.68 SE 0 4 0 0 0 0 4 6.63 SSE 0 1 0 0 0 0 1 6.87 S 0 3 1 0 0 0 4 7.10 SSW 0 2 8 1 0 0 11 10.09 SW 1 3 1 2 0 0 7 8.72 WSW 2 4 3 0 0 0 9 6.43 W 0 6 1 0 0 0 7 7.36 WNW 0 3 0 0 0 0 3 6.38 NW 2 1 1 0 0 0 4 5.91 NNW 1 1 3 2 3 1 11 15.15 Total 9 46 38 23 7 1 124 Hours of Calm : 0 Hours of Varying Wind Direction 0 Hours of Missing Data : 0 Hours of Missing Data for All : 5 Hours of No Stability Class 0 Total hours of observation : 2160 TABLE 7 FIRST QUARTER 2002 PAGE 30F8
JOINT WIND FREQUENCY DISTRIBUTION BY STABILITY CLASS SITE: V. C. SUMMER Nuclear Station UNIT 1 Report Date : 03-02-26 Data Period : 2 1 00:00 to 2- 3-31 23:00 Stability Class: D delta T/ delta z 61->10 m Delta T With Substitution Wind Sensor Height : 10 meter Hours at Each Wind Direction and Speed Wind_ __ __ __ ___ __ Wind______Speed______(miles/hour)__________
Wind Wind Speed (miles/hour)
Direction mean 0.75- <4 4- <8 8- <13 13- <19 19- 24 >24 Total' Speed N 9 5 6 6 1 1 28 8. 92 NNE 8 15 16 11 2 0 52 9.43 NE 8 17 55 35 0 0 115 10.91 ENE 3 9 50 8 0 0 70 9. 90 E 3 25 24 3 0 0 55 8.20 ESE 1 18 6 1 0 0 26 7.27 SE 7 21 7 0 0 0 35 6.35 SSE 5 10 6 0 0 0 21 6.00 S 2 13 5 0 0 0 20 6.22 SSW 3 15 10 0 0 0 28 7.64 SW 9 20 16 0 0 0 45 7.08 8 16 14 0 0 0 38 6. 84 WSW 7.07 W 11 37 29 1 0 0 78 WNW 14 27 3 0 0 0 44 4.78 NW 12 25 7 0 0 0 44 5.69 11 9 2 0 44 8 . 87 NNW 12 10 743__________
Total 115 283 265 74 5 1 743 Hours of Calm 0 Hours of Varying Wind Direction 0 Hours of Missing Data 5 Hours of Missing Data for All 5 Hours of No Stability Class 0 Total hours of observation 2160 TABLE 7 FIRST QUARTER 2002 PAGE 40F8
JOINT WIND FREQUENCY DISTRIBUTION BY STABILITY CLASS SITE: V. C. SUMMER Nuclear Station UNIT 1 Report Date : 03-02-26 Data Period : 2 1 00:00 to 2- 3-31 23:00 Stability Class: E delta T/ delta z 61->10 m Delta T With Substitution Wind Sensor Height : 10 meter Hours at Each Wind Direction and Speed Wind Wind Speed (miles/hour)
Direction Mean 0.75- <4 4- <8 8- <13 13- <19 19- 24 >24 Total' Speed N 4 9 8 2 0 0 23 7.29 NNE 1 10 1 1 0 0 13 6.85 NE 7 8 2 1 0 0 18 5.77 ENE 8 7 6 0 0 0 18 6.36 E 7 11 11 0 0 0 29 6.42 ESE 2 18 7 0 0 0 27 6.60 SE 8 24 6 0 0 0 38 5.75 SSE 4 28 4 0 0 0 36 5.72 S 7 38 17 0 0 0 62 6. 65 SSW 7 41 8 0 0 0 56 6.26 SW 25 57 7 0 0 0 89 5.28 WSW 23 41 10 0 0 0 74 5.19 W 16 67 3 0 0 0 86 5. 18 WNW 10 11 1 0 0 0 22 4.34 NW 14 11 0 0 0 0 25 4.35 NNW 3 9 6 0 0 0 18 6 . 93 Total 143 390 97 4 0 0 634 Hours of Calm 0 Hours of Varying Wind Direction: 0 Hours of Missing Data : 0 Hours of Missing Data for All : 5 Hours of No Stability Class : 0 Total hours of observation 2160 TABLE 7 FIRST QUARTER 2002 PAGE 50F8
JOINT WIND FREQUENCY DISTRIBUTION BY STABILITY CLASS SITE: V. C. SUMMER Nuclear Station UNIT 1 Report Date : 03-02-26 Data Period : 2 1 00:00 to 2- 3-31 23:00 Stability Class: F delta T/ delta z 61->10 m Delta T With Substitution Wind Sensor Height : 10 meter Hours at Each Wind Direction and Speed Wind Wind Speed (miles/hour)
Direction Meant 0.75- <4 4- <8 8- <13 13- <19 19- 24 >24 Total' Speed N 1 0 1 0 0 0 2 5.56 NNE 2 2 0 0 0 0 4 3.99 NE 2 1 0 0 0 0 3 3.50 ENE 2 0 0 0 0 0 2 1. 85 E 2 1 0 0 0 0 3 4. 15 ESE 2 0 0 0 0 0 2 2. 10 SE 6 5 1 0 0 0 12 4.40 SSE 5 17 0 0 0 0 22 5. 16 S 13 28 1 0 0 0 42 5.00 SSW 12 26 1 0 0 0 39 4.69 SW 15 28 0 0 0 0 43 4. 17 WSW 14 6 0 0 0 0 20 3.59 W 9 15 0 0 0 0 24 4.17 WNW 7 1 0 0 0 0 8 3. 16 NW 1 4 0 0 0 0 5 4.45 NNW 3 1 0 0 0 0 4 3. 94 Total 96 135 4 0 0 0 235 Hours of Calm : 0 Hours of Varying Wind Direction 0 Hours of Missing Data 0 Hours of Missing Data for All : 5 Hours of No Stability Class : 0 Total hours of observation : 2160 TABLE 7 FIRST QUARTER 2002 PAGE 60F8
JOINT WIND FREQUENCY DISTRIBUTION BY STABILITY CLASS SITE: V. C. SUMMER Nuclear Station UNIT 1 Report Date : 03-02-26 -
Data Period : 2 1 00:00 to 2- 3-31 23:00 Stability Class: G delta T/ delta z 61->10 m Delta T With Substitution Wind Sensor Height : 10 meter Hours at Each Wind Direction and Speed Wind Wind Speed (miles/hour)
Direction Mean 0.75- <4 4- <8 8- <13 13- <19 19- 24 >24 Total' Speed N 2 0 0 0 0 0 2 1.96 NNE 0 1 0 0 0 0 1 5.05 NE 0 0 0 0 0 0 0 0.00 ENE 2 .0 0 0 0 0 2 2.42 E 1 0 0 0 0 0 1 2.55 ESE 1 0 0 0 0 0 1 2.42 SE 3 0 0 0 0 0 3 1.91 SSE 7 16 0 0 0 0 23 4.85 S 14 23 0 0 0 0 37 4.42 SSW 16 6 0 0 0 0 22 3.26 SW 18 3 0 0 0 0 21 2.97 WSW 21 10 0 0 0 0 31 3.26 W 29 4 0 0 0 0 33 3.08 WNW 22 2 0 0 0 0 24 2.68 NW 5 0 0 0 0 0 5 2.84 NNW 3 1 0 0 0 0 4 2.77 Total 144 66 0 0 0 0 210 Hours of Calm : 1 Hours of Varying Wind Direction : 0 Hours of Missing Data : 0 Hours of Missing Data for All : 5 Hours of No Stability Class 0 Total hours of observation : 2160 TABLE 7 FIRST QUARTER 2002 PAGE 70F8
JOINT WIND FREQUENCY DISTRIBUTION BY STABILITY CLASS SITE: V. C. SUMMER Nuclear Station UNIT 1 Report Date : 03-02-26 Data Period : 2 1 00:00 to 2- 3-31 23:00 Stability Class:ALL delta T/ delta z 61->10 m Delta T With Substitution Wind Sensor Height : 10 meter Hours at Each Wind Direction and Speed Win__ __ __ __ ___ __ Wind __ __Speed
__ (miles/hour)____________________
.Wind- Wind Speed (miles/hour)
Direction Mean 0.75- <4 4- <8 8- <13 13- <19 19- 24 >24 Total' Speed N 19 19 15 10 3 1 67 8.14 NNE 14 39 21 24 9 0 107 9. 91 NE 18 35 67 41 0 0 161 10. 01 ENE 12 24 58 8 0 0 102 8. 64 E 13 44 41 3 0 0 101 7.45 ESE 6 38 15 1 0 0 60 6.77 SE 24 58 16 0 0 0 98 5.81 SSE 21 72 10 0 0 0 103 5.48 S 37 108 25 0 0 0 170 5.69 SSW 39 99 37 1 0 0 176 6 .09 SW 72 128 34 3 0 0 237 5.58 WSW 71 90 38 2 0 0 201 5.45 W 67 140 43 1 0 0 251 5. 68 WNW 54 48 24 2 0 0 128 5.35 NW 34 44 14 2 0 0 94 5.61 NNW 28- 27 23 13 6 1 98 8.57 Total 529 1013 481 111 18 2 2154 Hours of Calm : 1 Hours of Varying Wind Direction : 0 Hours of Missing Data for All : 5 Hours of No Stability Class : 0 Total hours of observation : 2160 TABLE 7 FIRST QUARTER 2002 PAGE 80F8
JOINT WIND FREQUENCY DISTRIBUTION BY STABILITY CLASS SITE: V. C. SUMMER Nuclear Station UNIT 1 Report Date : 03-02-26 Data Period : 2 1 00:00 to 2- 6-30 23:00 Stability Class: A delta T/ delta z 61->10 m Delta T With Substitution Wind Sensor Height : 10 meter Hours at Each Wind Direction and Speed Wind Wind Speed (miles/hour)
Mean Direction 19- 24 >24 Total' Speed 0.75- <4 4- <8 8- <13 13- <19 0 0 0 2 4.89 N 0 2 0 5 0 0 0 0 4.53 NNE 2 3 5 4.79 NE 2 3 0 0 0 0 o 0 6 4.59 ENE 0 6 0 0 4 3 0 0 0 0 5.69 E 1 1 10.23 ESE 0 0 1 0 0 0 0 0 2 7.60 SE 0 1 1 0 1 1 0 0 0 0 5.40 SSE 0 4 10.32 0 2 0 2 0 0 S 0 1 9.51 SSW 0 0 1 0 0 0 0 5 7.38 SW 0 2 3 0 20 11 8 1 0 0 8.14 WSW 0 13 8.88 W 0 4 9 0 0 0 0 0 4 10.67 WNW 0 0 4 0 0 0 0 0 0 . 00 NW 0 0 0 3 2 1 0 0 0 0 3.92 NNW 39 27 3 0 0 76 Total 7 Hours of Calm 0 Hours of Varying Wind Direction : 0 Hours of Missing Data 153 Hours of Missing Data for All 1143 Hours of No Stability Class 53 Total hours of observation 2184 TABLE 7 SECOND QUARTER 2002 PAGE I OF 8
JOINT WIND FREQUENCY DISTRIBUTION BY STABILITY CLASS SITE: V. C. SUMMER Nuclear Station UNIT 1 Report Date : 03-02-26 Data Period : 2 1 00:00 to 2- 6-30 23:00 Stability Class: B delta T/ delta z 61->10 m Delta T With Substitution Wind Sensor Height : 10 meter Hours at Each Wind Direction and Speed Wind Wind Speed (miles/hour)
Direction >24 Total' Speed 0.75- <4 4- <8 8- <13 13- <19 19- 24 N 3 1 0 1 0 0 5 6.83 NNE 0 0 0 0 0 0 0 0.00 NE 2 0 0 0 0 0 2 3.21 1 3 1 1 0 0 6 6.79 ENE 7.65 E 1 3 4 0 0 0 8 0 0 1 0 0 0 1 9.71 ESE SE 0 0 0 0 0 0 0 0.00 0 0 0 0 0 0 0 0.00 SSE S 0 4 3 2 0 0 9 9.23 0 4 1 0 0 0 5 7.13 SSW 7.15 SW 0 4 2 0 0 0 6 WSW 0 6 7 1 0 0 14 8.56 W 0 5 8 0 0 0 13 8.75 WNW 0 1 4 0 0 0 5 9.56 NW 0 0 0 0 0 0 0 0.00 NNW 1 0 0 0 0 0 1 3.13 8 31 31 5 0 0 75 Total Hours of Calm : 0 Hours of Varying Wind Direction : 0 Hours of Missing Data : 90 Hours of Missing Data for All : 1143 Hours of No Stability Class : 53 Total hours of observation : 2184 TABLE 7 SECOND QUARTER 2002 PAGE 2 OF 8
JOINT WIND FREQUENCY DISTRIBUTION BY STABILITY CLASS SITE: V. C. SUMMER Nuclear Station UNIT 1 Report Date : 03-02-26 Data Period : 2 1 00:00 to 2- 6-30 23:00 Stability Class: C delta T/ delta z 61->10 m Delta T With Substitution Wind Sensor Height : 10 meter Hours at Each Wind Direction and Speed Wind Wind Speed (miles/hour)
Mean Direction 13- <19 19- 24 >24 Total' Speed 0.75- <4 4- <8 8- <13 1 0 0 0 0 2 3.73 N 1 9.72 0 3 4 1 0 0 8 NNE 9 12.06 0 2 3 3 1 0 NE 0 4 10.88 ENE 0 1 1 2 0 0 2 0 0 0 2 9.83 E 0 9.58 0 0 1 0 0 0 1 ESE 0 1 8.79 SE 0 0 1 0 0 3 1 0 0 0 4 7.62 SSE 0 9.93 0 1 6 1 0 0 8 S 0 8 7.28 SSW 1 4 3 0 0 5 0 0 0 0 6 6.34 SW 1 8.33 2 5 5 0 0 0 12 WSW 0 9 8.78 W 0 3 6 0 0 1 1 2 0 0 0 4 7.17 WNW 0 0.00 NW 0 0 0 0 0 0 0 2 0 0 0 0 2 6.55 NNW ___________________________________________________________________________
6 31 35 7 1 0 80 Total Hours of Calm : 0 Hours of Varying Wind Direction : 0 Hours of Missing Data : 93 Hours of Missing Data for All 1143 Hours of No Stability Class : 53 Total hours of observation 2184 TABLE 7 SECOND QUARTER 2002 PAGE 30F8
JOINT WIND FREQUENCY DISTRIBUTION BY STABILITY CLASS SITE: V. C. SUMMER Nuclear Station UNIT 1 Report Date : 03-02-26 Data Period : 2 1 00:00 to 2- 6-30 23:00 Stability Class: D delta T/ delta z 61->10 m Delta T With Substitution Wind Sensor Height : 10 meter Hours at Each Wind Direction and Speed T.Tj -A nCooA {m; 1 An2 /hnnirr Wind W.lna >p - - - IMean Direction 19- 24 >24 Total' Speed 0.75- <4 4- <8 8- <13 13- <19 2 0 1 15 10.00 N 1 8 3 1 10.15 16 15 14 0 50 NNE 4 2 0 43 10.08 NE 3 13 16 9 7 0 0 50 9.88 ENE 3 12 28 0 7.46 23 12 1 0 38 E 2 0 7 5.20 3 1 0 0 ESE 3 0 0 3 5.33 SE 0 3 0 0 0 0 0 13 6.77 SSE 3 6 4 9 3 0 0 33 7.99 S 1 20 0 7.62 22 8 3 0 33 SSW 0 0 40 6.73 4 23 13 0 0 SW 0 0 30 6.77 WSW 4 18 7 1 9 0 0 0 18 7.45 W 2 7 0 5.52 9 1 0 0 12 WNW 2 0 6 5. 01 3 1 2 0 0 NW 0 0 6 4.75 NNW 3 2 1 0 186 129 40 3 1 397 Total 38 Hours of Calm : 0 Hours of Varying Wind Direction 0 Hours of Missing Data 380 Hours of Missing Data for All 1143 Hours of No Stability Class : 53 Total hours of observation 2184 TABLE 7 SECOND QUARTER 2002 PAGE 40F8
CLASS JOINT WIND FREQUENCY DISTRIBUTION BY STABILITY SITE: V. C. SUMMER Nuclear Station UNIT 1 Report Date : 03-02-26 Data Period : 2 1 00:00 to 2- 6-30 23:00 Stability Class: E delta T/ delta z 61->10 m Delta T With Substitution Wind Sensor Height : 10 meter Hours at Each Wind Direction and Speed Wind Wind Speed (miles/hour)
Mean Direction 8- <13 13- <19 19- 24 >24 Total' Speed 0.75- <4 4- <8 2 3 2 0 0 9 8.89 N 2 10 3.84 5 5 0 0 0 0 NNE 0 0 9 4.98 NE 2 7 0 0 2 2 0 0 0 5 6.75 ENE 1 23 5.37 4 19 0 0 0 0 E 0 0 12 4.95 ESE 4 7 0 0 12 1 0 0 0 16 5.22 SE 3 22 6.04 2 16 4 0 0 0 SSE 0 39 5.62 7 27 5 0 0 S 0 0 41 5.52 SSW 9 29 3 0 39 2 0 0 0 51 5.52 SW 10 41 5.37 10 27 4 0 0 0 WSW 0 0 23 5.63 W 4 19 0 0 7 0 0 0 0 10 4.36 WNW 3 3 2.45 3 0 0 0 0 0 NW 0 2 7.46 NNW 0 1 1 0 0 219 25 2 0 0 315 Total 69 Hours of Calm : 0 Hours of Varying Wind Direction : 0 Hours of Missing Data : 219 Hours of Missing Data for All 1143 Hours of No Stability Class : 53 Total hours of observation : 2184 TABLE 7 SECOND QUARTER 2002 PAGE 50F8
CLASS JOINT WIND FREQUENCY DISTRIBUTION BY STABILITY SITE: V. C. SUMMER Nuclear Station UNIT 1 Report Date : 03-02-26 Data Period : 2 1 00:00 to 2- 6-30 23:00 Stability Class: F delta T/ delta z 61->10 m Delta T With Substitution Wind Sensor Height : 10 meter Hours at Each Wind Direction and Speed Wind Wind Speed (miles/hour) ?A.ArI Direction 19- 24 >24 Total' Speed 0.75- <4 4- <8 8- <13 13- <19
_ _ _ _0__ _ _ _ _ _ _ _ _ _ _ _0__ _ _ _ _0__ _ _ _ _0__ _ _ _ _ _ _ _
N__ 2 0 0. 00 N 0 0 0 0 0 0 0 2 0 .00 NNE 0 0 0 0 2 0 0 0. 00 NE 0 0 0 0 o 0 0 0 0.00 ENE 0 0 0 o 3 3.33 E 2 1 0 0 0 0 2 0 0 1.55 ESE 2 0 0 0 3 4.72 SE 1 2 0 0 0 0 15 0 0 4.48 SSE 6 9 0 5.41 1 0 0 0 16 S 3 12 9 5.02 6 0 0 0 0 SSW 3 0 10 3.41 SW 4 6 0 0 0 0 0 0 0 8 2.65 WSW 7 1 3 3.78 1 0 0 0 0 W 2 0 4 2.78 WNW 3 1 0 0 0 0 0 0 0 6 4.37 NW 1 5 0 .00 0 0 0 0 0 NNW 0 0 44 1 0 0 0 79 Total 34 0
Hours of Calm 0 Hours of Varying Wind Direction of Missing Data :80 Hours Hours of Missing Data for All 1143 Hours of No Stability Class 53 Total hours of observation 2184 TABLE 7 SECOND QUARTER 2002 PAGE 60F8
JOINT WIND FREQUENCY DISTRIBUTION BY STABILITY CLASS SITE: V. C. SUMMER Nuclear Station UNIT 1 Report Date : 03-02-26 Data Period : 2 1 00:00 to 2- 6-30 23:00 Stability Class: G delta T/ delta z 61->10 m Delta T With Substitution Wind Sensor Height : 10 meter Hours at Each Wind Direction and Speed Wind Wind Speed (miles/hour) I Direction 19- 24 >24 Total' Speed 0.75- <4 4- <8 8- <13 13- <19 0 0 0 0 0 0.00 N 0 0 0 0 0.00 0 0 0 0 NNE 0 0 0 0 0 0.00 NE 0 0 0 0 0 0 0 0 0.00 ENE 0 0 0 0 0.00 0 0 0 0 E 0 0 0 0.00 0 0 0 0 ESE 0 0 0 0 1 6.85 SE 0 1 0 0 0 0 6 5.68 SSE 0 6 0 0 0 0 5 4.88 S 2 3 0 0 0 0 0 0.00 SSW 0 0 0 0 0 0 0 0 0.00 SW 0 0 0 0 0 0 2 2.72 WSW 2 0 0 0 2 3.01 0 0 0 W 2 0 0 0 2 3.12 WNW 2 0 0 0 0 0 0 0.00 NW 0 0 0 0 0 0 0 0.00 NNW 0 0 0 _______________
Tota_________________8______10________0______0_____0______0__
10 0 0 0 0 18 Total 8 of Calm 1 Hours Hours of Varying Wind Direction 0 Hours of Missing Data 75 Hours of Missing Data for All 1143 Hours of No Stability Class 53 Total hours of observation 2184 TABLE 7 SECOND QUARTER 2002 PAGE 70F8
JOINT WIND FREQUENCY DISTRIBUTION BY STABILITY CLASS SITE: V. C. SUMMER Nuclear Station UNIT 1 Report Date : 03-02-26 Data Period : 2 1 00:00 to 2- 6-30 23:00 Stability Class:ALL delta T/ delta z 61->10 m Delta T With Substitution Wind Sensor Height : 10 meter Hours at Each Wind Direction and Speed Wind Wind Speed (miles/hour) tM-Direction 0.75- <4 4- <8 8- <13 13- <19 19- 24 >24 Total' Speed 14 6 5 0 1 33 8. 53 N 7 8.85 NNE 11 27 19 15 1 0 73 25 19 12 3 0 68 9.08 NE 9 9.01 ENE 5 24 32 10 0 0 71 49 18 1 0 0 78 6 .68 E 10 5.37 ESE 9 10 4 0 0 0 23 19 3 0 0 0 26 5.56 SE 4 5.87 SSE 11 41 9 0 0 0 61 69 24 8 0 0 114 7.00 S 13 6.46 SSW 13 65 16 3 0 0 97 19 79 20 0 0 0 118 5.95 SW 6.56 WSW 25 68 31 3 0 0 127 10 39 32 0 0 0 81 7.27 W 6. 01 WNW 11 19 11 0 0 0 41 7 6 2 0 0 0 15 4.24 NW NNW 6 6 2 0 0 0 14 5.10 Total 170 560 248 57 4 1 1040 Hours of Calm 1 Hours of Varying Wind Direction 0 Hours of Missing Data for All 1143 Hours of No Stability Class 53 Total hours of observation 2184 TABLE 7 SECOND QUARTER 2002 PAGE 80F8
STABILITY CLASS JOINT WIND FREQUENCY DISTRIBUTION BY 1
SITE: V. C. SUMMER Nuclear Station UNIT Report Date : 03-02-26 2- 9-30 23:00 Data Period : 2 1 00:00 to delta T/ delta z 61->10 m Delta T With Substitution Stability Class: A Wind Sensor Height : 10 meter Hours at Each Wind Direction and Speed Wind Wind Speed (miles/hour) Mean Direction 13- <19 19- 24 >24 Total' Speed 0.75- <4 4- <8 8- <13 0 0 0 6 4.20 N 2 4 0 0 0 0 7 4.72 NNE 3 4 0 0 0 0 11 4.34 NE 7 3 1 0 0 0 15 7.00 ENE 0 10 5 0 0 0 13 7.19 E 1 8 4 0 0 0 2 7.54 ESE 0 1 1 0 0 0 4 6 . 96 SE 1 2 1 0 0 0 5 10.18 SSE 0 1 4 0 0 0 4 5.61 S 1 3 0 0 0 0 7 6.25 SSW 1 5 1 0 0 7 5.90 0
SW 1 5 1 0 0 0 30 5.83 WSW 2 27 1 0 0 0 25 6.80 W 3 16 6 0 0 0 6 7.36 WNW 0 4 2 0 0 0 1 5.18 NW 0 1 0 0 0 7 3.88 0
NNW 4 3 0 _ _ _ _ _
_____________________________________ 0 150 97 27 0 0 Total 26 0
Hours of Calm Hours of Varying Wind Direction : 0 of Missing Data 3 Hours : 245 Hours of Missing Data for All of No Stability Class 221 Hours 2208 Total hours of observation TABLE 7 THIRD QUARTER 2002 PAGE 1OF8
JOINT WIND FREQUENCY DISTRIBUTION BY STABILITY CLASS SITE: V. C. SUMMER Nuclear Station UNIT 1 Report Date : 03-02-26 Data Period : 2 1 00:00 to 2- 9-30 23:00 Stability Class: B delta T/ delta z 61->10 m Delta T With Substitution Wind Sensor Height : 10 meter Hours at Each Wind Direction and Speed Wind Wind Speed (miles/hour) 1~n Direction 19- 24 >24 Total' Speed 0.75- <4 4- <8 8- <13 13- <19 0 0 0 6 3.16 N 5 1 0 1 0 0 0 8 5.30 NNE 1 6 0 14 7.30 NE 1 8 4 1 0 0 0 14 7.87 ENE 1 5 8 0 0 7 0 0 16 7.89 E 1 8 0 6.80 6 0 0 0 6 ESE 0 0 1 9.42 SE 0 0 1 0 0 0 0 2 9. 94 SSE 0 0 2 0 0 1 0 0 4 6.59 S 0 3 0 5.94 2 1 0 0 4 SSW 1 0 4 6.51 SW 1 2 1 0 0 0 0 0 9 4.70 WSW 1 8 0 0 1 0 0 9 5.65 W 1 7 0 6.25 8 2 0 0 10 WNW 0 0 4 5.58 NW 0 4 0 0 0 0 0 0 5 3.45 NNW 4 1 0 69 29 1 0 0 116 Total 17 Hours of Calm 0 of Varying Wind Direction 0 Hours 0 Hours of Missing Data Hours of Missing Data for All 245 Hours of No Stability Class 221 Total hours of observation 2208 TABLE 7 THIRD QUARTER 2002 PAGE 20F8
CLASS JOINT WIND FREQUENCY DISTRIBUTION BY STABILITY SITE: V. C. SUMMER Nuclear Station UNIT 1 Report Date : 03-02-26 Data Period : 2 1 00:00 to 2- 9-30 23:00 Stability Class: C delta T/ delta z 61->10 m Delta T With Substitution Wind Sensor Height : 10 meter Hours at Each Wind Direction and Speed Mmn Wind Wind Speed (miles/hour) l Direction 19- 24 >24 Total' Speed 0.75- <4 4- <8 8- <13 13- <19
___4__5_0__0__0_0 0 0 9 3. 95 N 4 5 0 0 0 0 0 10 5.05 NNE 4 5 1 8.66 4 0 0 30 NE 0 14 12 8.89 0 0 0 27 ENE 1 7 19 7.76 0 0 0 19 E 1 9 9 7. 94 0 0 0 6 ESE 0 3 3 7.61 1 0 0 0 3 SE 0 2 5 7.33 0 3 2 0 0 0 SSE 0 5 7.35 0 4 1 0 0 S 5 5.63 1 4 0 0 0 0 SSW 3 6.40 0 2 1 0 0 0 SW 0 4 4.61 1 3 0 0 0 WSW 0 7 4.25 3 4 0 0 0 W 8 4.32 3 5 0 0 0 0 WNW 9 4.78 4 4 1 0 0 0 NW 10 6.35 3 3 4 0 0 0 NNW _____________________________________________________________
54 4 0 0 160 Total 25 77 0
Hours of Calm 0 Hours of Varying Wind Direction 1
Hours of Missing Data Hours of Missing Data for All 245 Hours of No Stability Class 221 Total hours of observation 2208 TABLE 7 THIRD QUARTER 2002 PAGE 30F8
CLASS JOINT WIND FREQUENCY DISTRIBUTION BY STABILITY SITE: V. C. SUMMER Nuclear Station UNIT 1 Report Date : 03-02-26 Data Period : 2 1 00:00 to 2- 9-30 23:00 Stability Class: D delta T/ delta z 61->10 m Delta T With Substitution Wind Sensor Height : 10 meter Hours at Each Wind Direction and Speed Wind Wind Speed (miles/hour) Msn I Direction 19- 24 >24 Total' Speed 0.75- <4 4- <8 8- <13 13- <19 1 0 0 57 6.74 N 8 33 15 8.12 37 7 0 0 84 NNE 12 28 203 11.28 19 127 51 0 0 NE 6 0 178 9.57 ENE 6 42 117 13 0 3 0 0 68 7. 93 E 4 31 30 7.24 8 0 0 0 36 ESE 0 28 35 7.59 23 9 2 0 0 SE 1 0 32 8.74 SSE 1 11 18 2 0 3 0 0 44 7.59 S 3 28 10 7.40 8 3 0 0 32 SSW 8 13 28 5.68 14 5 0 0 0 SW 9 0 19 4.78 WSW 7 9 3 0 0 0 0 0 20 4.53 W 10 9 1 4.36 10 1 0 0 0 22 WNW 11 0 17 4.86 NW 6 10 1 0 0 0 0 0 34 5.44 NNW 12 17 5 395 85 0 0 909 Total 104 325 Hours of Calm : 0 Hours of Varying Wind Direction : 0 Hours of Missing Data 10 Hours of Missing Data for All 245 Hours of No Stability Class 221 Total hours of observation 2208 TABLE 7 THIRD QUARTER 2002 PAGE 4 OF 8
CLASS JOINT WIND FREQUENCY DISTRIBUTION BY STABILITY SITE: V. C. SUMMER Nuclear Station UNIT 1 Report Date : 03-02-26 Data Period : 2 1 00:00 to 2- 9-30 23:00 Stability Class: E delta T/ delta z 61->10 m Delta T With Substitution Wind Sensor Height : 10 meter Hours at Each Wind Direction and Speed Wind Wind Speed (miles/hour)
Direction 4- <8 8- <13 13- <19 19- 24 >24 Total' Mean Speed 0.75- <4 0 0 0 9 8.24 N 0 5 4 0 5.64 2 0 0 10 NNE 5 3 0 0 0 11 6.62 2 5 NE 4 5 0 0 0 17 5.43 ENE 8 4 0 0 0 27 6.49 6 11 1.0 E 1 0 0 0 25 5.29 ESE 7 17 0 0 0 39 4. 92 15 22 2 SE 2 0 0 0 48 4.81 SSE 14 32 0 0 0 43 4.83 28 2 S 13 5 0 0 0 55 4.88 SSW 21 29 0 0 0 56 4.16 25 31 0 SW 1 0 0 0 41 3;83 WSW 23 17 0 0 0 34 3.61 21 13 0 W 0 0 0 0 21 3.01 WNW 18 3 0 0 0 12 3.33 3 0 NW 9 0 0 0 19 4.69 9 9 1 NNW 40 0 0 0 467 Total 198 229 1
Hours of Calm 0 Hours of Varying Wind Direction Hours of Missing Data 9 Hours of Missing Data for All 245 Hours of No Stability Class 221 Total hours of observation 2208 TABLE 7 THIRD QUARTER 2002 PAGE 50F8
BY STABILITY CLASS JOINT WIND FREQUENCY DISTRIBUTION UNIT 1 SITE: V. C. SUMMER Nuclear Station Report Date : 03-02-26 to 2- 9-30 23:00 Data Period : 2 1 00:00 T With Substitution Stability Class: F delta T/ delta z 61->10 m Delta Wind Sensor Height : 10 meter Speed Hours at Each Wind Direction and Wind Wind Speed (miles/hour)
Mean Direction 13- c19 19- 24 >24 Total' Speed
- .A A-A eP 8- <13 I u~~ .,, - - - -
_ _ _ _ _ _ _ _ __0 0 0 5 3.93 0 0 N 2 3 0 0 0 2 2.37 NNE 2 0 0 0 0 0 0 0 .00 NE 0 0 0 0 0 0 0 0 . 00 ENE 0 0 0 0 0 0 0 .00 0
E 0 0 0 0 0 0 1 3. 90 ESE 1 0 0 0 0 0 6 3.87 SE 2 4 0 0 0 0 16 4.67 SSE 5 11 0 0 0 0 12 4.17 S 5 7 0 0 0 0 23 4.22 SSW 10 12 1 0 0 0 13 2.30 SW 12 1 0 0 0 0 10 2.78 WSW 9 1 0 0 0 0 17 3.29 W 12 5 0 0 0 0 6 2.29 WNW 6 0 0 0 0 0 4 2.41 NW 4 0 0 0 0 0 2 4.35 NNW 1 1 0
__________0____0___0____1_
0 0 0 1 17 Total 71 45 1 Hours of Calm 0 0
Hours of Varying Wind Direction :
Hours of Missing Data : 1 Hours of Missing Data for All : 245 Hours of No Stability Class : 221 Total hours of observation : 2208 TABLE 7 THIRD QUARTER 2002 PAGE 60F8
BY STABILITY CLASS JOINT WIND FREQUENCY DISTRIBUTION UNIT 1 SITE: V. C. SUMMER Nuclear Station Report Date : 03-02-26 to 2- 9-30 23:00 Data Period : 2 1 00:00 delta T/ delta z 61->10 m Delta T With Substitution Stability Class: G Wind Sensor Height : 10 meter Speed Hours at Each Wind Direction and Wind Wind Speed (miles/hour) MearL Direction 19- 24 >24 Total' Speed r -A A. AR 8- <13 13- <19 U. ID- -- - - _
0_ . 00__
_ _ _ _ _ _ _ _ _ _ _ _ _ _.0 -- -- 0 0 ._ _ _ _ 0 0 0 0 0 0.00 N 0 0 0 0 0 0 0.00 0
NNE 0 0 0 0 0 0 0.00 0
NE 0 0 0 0 0 0 0 0.00 ENE 0 0 0 0 0 0 0.00 0
E 0 0 0 0 0 0 0 0.00 ESE 0 0 0 0 0 0 0 0.00 SE 0 0 0 0 0 0 0. 00 0
SSE 0 0 0 0 0 0 4 3.39 S 3 1 0 0 0 5 2.76 0
SSW 4 1 0 0 0 6 3.68 0
SW 3 3 0 0 0 9 2.94 0
WSW 6 3 0 0 0 0 7 2.24 W 7 0 0 0 0 9 2.96 0
WNW 8 1 0 0 0 3 2.17 0
NW 3 0 0 0 0 0 0.00 0
NNW 0 0 0 0 0 0 43 34 9 0 Total 0
Hours of Calm 0 Hours of Varying Wind Direction 0 Hours of Missing Data 245 Hours of Missing Data for All 221 Hours of No Stability Class 2208 Total hours of observation TABLE 7 THIRD QUARTER 2002 PAGE 70F8
JOINT WIND FREQUENCY DISTRIBUTION BY STABILITY CLASS SITE: V. C. SUMMER Nuclear Station UNIT 1 Report Date : 03-02-26 Data Period : 2 1 00:00 to 2- 9-30 23:00 Stability Class:ALL delta T/ delta z 61->10 m Delta T With Substitution Wind Sensor Height : 10 meter Hours at Each Wind Direction and Speed Wind Wind Speed (miles/ hour)
Meean Direction 19- 24 >24 Total' Speed 0.75- <4 4- <8 8- <13 13- <19 1 0 0 92 6.06 N 21 51 19 41 7 0 0 121 7.19 NNE 27 46 10.30 149 56 0 0 269 NE 18 46 8. 97 154 13 0 0 251 ENE 16 68 7. 56 60 3 0 0 143 E 13 67 6.58 13 0 0 0 76 ESE 8 55 6.15 14 2 0 0 88 SE 19 53 6.41 58 28 2 0 0 108 SSE 20 5.95 74 14 3 0 0 116 S 25 5.43 66 16 3 0 0 131 SSW 46 4.54 58 8 0 0 0 117 SW 51 4.41 68 5 0 0 0 122 WSW 49 4.50 54 8 0 0 0 119 W 57 4.15 31 5 0 0 0 82 WNW 46 4. 19 22 2 0 0 0 50 NW 26 5.07 34 10 0 0 0 77 NNW 33 851 546 90 0 0 1962 Total 475 Hours of Calm 1 Hours of Varying Wind Direction 0 Hours of Missing Data for All 245 Hours of No Stability Class 221 Total hours of observation 2208 TABLE 7 THIRD QUARTER 2002 PAGE 80F8
JOINT WIND FREQUENCY DISTRIBUTION BY STABILITY CLASS SITE: V. C. SUMMER Nuclear Station UNIT 1 Report Date : 03-02-26 Data Period : 2 1 00:00 to 2-12-31 23:00 Stability Class: A delta T/ delta z 61->10 m Delta T With Substitution Wind Sensor Height : 10 meter Hours at Etch Wind Direction and Speed Wind Wind Speed (miles/hour)
Direction Mean 4- <8 8- <13 13- <19 19- 24 >24 Total' Speed 0.75- <4 - - - - - -
3 1 2 0 0 0 6 5.60 N
4 1 0 0 0 0 5 3.70 NNE 3 1 0 1 0 0 5 5.77 NE 0 3 0 0 0 0 3 6.54 ENE 0 1 0 0 0 0 1 5.41 E
0 0 0 0 0 0 0 0.00 ESE 0 0 0 0 0 0 0 0.00 SE 0 0 0 0 0 0 0 0.00 SSE 0 1 0 0 0 0 1 4.87 S
0 3 0 0 0 0 3 5.16 SSW 3 15 2 0 0 0 20 5.80 SW 4 14 3 1 0 0 22 6.01 WSW W 5 4 2 0 0 0 11 5.07 2 5 1 0 0 0 8 5.78 WNW 1 1 3 0 0 0 5 9.30 NW NNW 2 2 0 0 0 0 4 4.52 Total 27 52 13 2 0 0 94 Hours of Calm : 0 Hours of Varying Wind Direction : 0 Hours of Missing Data : 0 Hours of Missing Data for All 79 Hours of No Stability Class 72 Total hours of observation : 2208 TABLE 7 FOURTH QUARTER 2002 PAGE I OF 8
JOINT WIND FREQUENCY DISTRIBUTION BY STABILITY CLASS SITE: V. C. SUMMER Nuclear Station UNIT 1 Report Date : 03-02-26 Data Period : 2 1 00:00 to 2-12-31 23:00 Stability Class: B delta T/ delta z 61->10 m Delta T With Substitution Wind Sensor Height : 10 meter Hours at Each Wind Direction and Speed Wind Wind Speed (miles/hour) I M==n Direction >24 Total' Speed 0.75- <4 4- <8 8- <13 13- <19 19- 24 2 0 0 0 3 8.06 N 1 0 12.36 1 0 3 0 0 4 NNE 0 0 6 9.16 NE 0 3 2 1 0 0 0 0 4 6.48 ENE 1 2 1 0 0 0 0 3 5.46 E 1 2 0 3.31 0 0 0 0 2 ESE 2 0 0 0. 00 SE 0 0 0 0 0 0 0 0 1 7.08 SSE 0 1 0 0 2 2 0 4 11.28 S 0 0 0 6.64 5 4 0 0 12 SSW 3 0 7 4.73 SW 3 4 0 0 0 7 0 0 24 8.52 WSW 5 7 5 0 6 2 3 0 17 7.01 W 6 0 6 6.44 WNW 0 5 1 0 0 0 0 0 8 7.36 NW 3 1 4 0 0 2 1 0 4 9.15 NNW 1 26 37 25 17 0 0 105 Total Hours of Calm 0 Hours of Varying Wind Direction 0 Hours of Missing Data 0 Hours of Missing Data for All 79 Hours of No Stability Class 72 Total hours of observation 2208 TABLE 7 FOURTH QUARTER 2002 PAGE 20F8
JOINT WIND FREQUENCY DISTRIBUTION BY STABILITY CLASS SITE: V. C. SUMMER Nuclear Station UNIT 1 Report Date : 03-02-26 Data Period : 2 1 00:00 to 2-12-31 23:00 Stability Class: C delta T/ delta z 61->10 m Delta T With Substitution Wind Sensor Height : 10 meter Hours at Each Wind Direction and Speed Wind Wind Speed (miles/hour) ~ lm Direction >24 Total' Speed 0.75- <4 4- <8 8- <13 13- <19 19- 24 4 3 1 0 0 8 9.53 N 0 5 3 2 9 0 0 19 10.44 NNE 24 13.65 1 2 5 16 0 0 NE 11.91 1 3 6 11 0 0 21 ENE 3 7.94 0 1 2 0 0 0 E 7.00 0 1 0 0 0 0 1 ESE 1 5.76 0 1 0 0 0 0 SE 8.54 0 0 1 0 0 0 1 SSE 3 7.26 1 0 2 0 0 0 S 7.04 0 4 0 0 0 0 4 SSW 5.81 2 7 1 0 0 0 10 SW 7.80 1 4 1 2 0 0 8 WSW 13 8.20 4 4 3 2 0 0 W
WNW 3 2 0 0 0 0 5 4.64 0 3 0 0 0 4 9.31 NW 1 1 0 1 0 0 4 6.32 NNW 2 21 37 29 42 0 0 129 -
Total of Calm 0 Hours Hours of Varying Wind Direction 0 of Missing Data 1 Hours Hours of Missing Data for All 79 Hours of No Stability Class 72 Total hours of observation 2208 TABLE 7 FOURTH QUARTER 2002 PAGE 30F8
JOINT WIND FREQUENCY DISTRIBUTION BY STABILITY CLASS SITE: V. C. SUMMER Nuclear Station UNIT 1 Report Date : 03-02-26 Data Period : 2 1 00:00 to 2-12-31 23:00 Stability Class: D delta T/ delta z 61->10 m Delta T With Substitution Wind Sensor Height : 10 meter Hours at Each Wind Direction and Speed Wind Wind Speed (miles/hour)
Direction _ _ _ _ MeanL-3 0.75- <4 4- <8 8- c13 13- c19 19- 24 >;&4 t1otzal- .5peu 7 10 16 0 0 0 33 7.64 N
NNE 10 11 21 7 0 0 49 8.58 NE 6 21 104 52 1 0 184 11. 12 ENE 5 30 104 36 0 0 175 10.44 E 3 19 28 5 0 0 55 8. 95 ESE 8 13 9 0 0 0 30 6.62 SE 6 10 3 0 0 0 19 5.52 SSE 5 6 4 0 0 0 15 6.15 S 4 5 9 2 0 0 20 8.25 SSW 6 11 15 3 1 0 36 8.20 SW 10 13 2 1 0 0 26 5.18 WSW 17 15 28 2 0 0 62 7.37 W 14 24 12 1 0 0 51 6.19 WNW 18 27 5 0 0 0 50 5.16 NW 10 45 4 0 0 0 59 5.25 NNW 7 22 14 0 0 0 43 6.73 Total__________136______282______378_______109______2____0___907____
Total 136 282 378 109 2 0 907 Hours of Calm : 0 Hours of Varying Wind Direction : 0 Hours of Missing Data : 3 Hours of Missing Data for All 79 Hours of No Stability Class 72 Total hours of observation 2208 TABLE 7 FOURTH QUARTER 2002 PAGE 40F8
JOINT WIND FREQUENCY DISTRIBUTION BY STABILITY CLASS SITE: V. C. SUMMER Nuclear Station UNIT 1 Report Date : 03-02-26 Data Period : 2 1 00:00 to 2-12-31 23:00 Stability Class: E delta T/ delta z 61->10 m Delta T With Substitution Wind Sensor Height : 10 meter Hours at Each Wind Direction and Speed Wind Wind Speed (miles/hour)
Direction -' -- A M, -. I t Mean'4 l -
0.75- <4 4- <8 8- <13 13- <19 .L!- Zk > It I LJ LuJ J N 3 1 0 0 0 0 4 3.02 NNE 1 4 2 0 0 0 7 6.82 NE 2 2 2 0 0 0 6 6.49 ENE 2 1 3 0 0 0 6 6.24 E 4 10 2 0 0 0 16 5.58 ESE 10 10 0 0 0 0 20 3.92 SE 11 8 0 0 0 0 19 4.08 SSE 3 6 4 0 0 0 13 6.57 S 6 18 7 0 0 0 31 6.44 SSW 11 10 1 1 0 0 23 4.67 SW 19 21 6 0 0 0 46 4.75 WSW 31 52 12 0 0 0 95 5.37 W 17 36 1 1 0 0 55 5.04 WNW 13 18 0 0 0 0 31 4.33 NW 11 8 0 0 0 0 19 4.17 NNW 8 5 2 0 0 0 15 4.50 Total 152 210 42 2 0 0 406 Hours of Calm : 0 Hours of Varying Wind Direction : 0 Hours of Missing Data : 1 Hours of Missing Data for All : 79 Hours of No Stability Class 72 Total hours of observation 2208 TABLE 7 FOURTH QUARTER 2002 PAGE 50F8
JOINT WIND FREQUENCY DISTRIBUTION BY STABILITY CLASS SITE: V. C. SUMMER Nuclear Station UNIT 1 Report Date : 03-02-26 Data Period : 2 1 00:00 to 2-12-31 23:00 Stability Class: F delta T/ delta z 61->10 m Delta T With Substitution Wind Sensor Height : 10 meter Hours at Each Wind Direction and Speed Wind Wind Speed (miles/hour) rLe1cL Direction >24 Total' Speed 0.75- <4 4- <8 8- <13 13- <19 19- 24 0 0 0 0 12 3.76 N 8 4 0 3.61 0 1 0 0 5 NNE 4 0 2 3 . 03 2 0 0 0 0 NE 0 0 3 2.14 ENE 3 0 0 0 0 0 0 3 3.85 E 2 1 0 0 0 0 0 9 2.42 ESE 9 0 0 3.17 1 0 0 0 6 SE 5 0 11 4.26 6 0 0 0 SSE 5 0 4.53 14 0 0 0 24 S 10 0 28 4.55 6 22 0 0 0 SSW 0 0 39 4.28 SW 17 22 0 0 0 0 0 0 28 3.42 WSW 20 8 0 4.15 11 9 0 0 0 20 W 0 21 4.01 WNW 7 14 0 0 0 0 0 0 0 16 3.38 NW 11 5 0 2.86 1 0 0 0 12 NNW 11
___________________________________________________ _______239______
131 107 1 0 0 0 239 Total Hours of Calm 1 Hours of Varying Wind Direction 0 Hours of Missing Data 1 Hours of Missing Data for All 79 Hours of No Stability Class 72 Total hours of observation 2208 TABLE 7 FOURTH QUARTER 2002 PAGE 60F8
JOINT WIND FREQUENCY DISTRIBUTION BY STABILITY CLASS SITE: V. C. SUMMER Nuclear Station UNIT 1 Report Date : 03-02-26 Data Period : 2 1 00:00 to 2-12-31 23:00 Stability Class: G delta T/ delta z 61->10 m Delta T With Substitution Wind Sensor Height : 10 meter Hours at Each Wind Direction and Speed Wind Wind Speed (miles/hour)
Direction >24 Total' Speed 0.75- <4 4- <8 8- <13 13- <19 19- 24 0 0 0 0 8 3. 51 N 7 1 0 0 0 0 0 9 3.01 NNE 9 2. 00 0 0 0 0 0 6 NE 6 1.96 0 0 0 0 0 2 ENE 2 0. 00 0 0 0 0 0 0 E 0 0 1 3.70 1 0 0 0 0 ESE 0 0 0 3 3.74 SE 2 1 0 0 0 0 0 9 3. 94 SSE 6 3 0 3.78 10 0 0 0 29 S 19 0 3.98 21 25 0 0 0 46 SSW 0 0 0 38 3.71 SW 22 16 0 0 0 0 0 40 3 .51 WSW 26 14 0 12 0 0 0 23 3.80 W 11 0 3.85 7 6 0 0 0 13 WNW 0 0 0 10 3. 13 NW 9 1 0 0 0 0 0 11 3 .31 NNW 9 2 0______248______
Tota________________157__________91________0_____0__
91 0 0 0 0 248 Total 157 Hours of Calm 0 Hours of Varying Wind Direction 0 Hours of Missing Data : 1 Hours of Missing Data for All : 79 Hours of No Stability Class : 72 Total hours of observation 2208 TABLE 7 FOURTH QUARTER 2002 PAGE 70F8
JOINT WIND FREQUENCY DISTRIBUTION BY STABILITY CLASS SITE: V. C. SUMMER Nuclear Station UNIT 1 Report Date : 03-02-26 Data Period : 2 1 00:00 to 2-12-31 23:00 Stability Class:ALL delta T/ delta z 61->10 m Delta T With Substitution Wind Sensor Height : 10 meter Hours at Each Wind Direction and Speed Wind Wind Speed (miles/hour)
PasCCLL Direction Speed 0.75- <4 4- <8 8- <13 13- <19 19- 24 >24 Total' 21 23 1 0 0 74 6.37 N 29 20 26 19 0 0 98 7.96 NNE 33 29 113 70 1 0 233 10.79 NE 20 39 114 47 0 0 214 10. 15 ENE 14 34 32 5 0 0 81 7.88 E 10 9 0 0 0 63 5.02 ESE 30 24 21 3 0 0 0 48 4.55 SE 24 22 9 0 0 0 50 5.51 SSE 19 48 20 4. 0 0 112 5.85 S 40 80 20 4 1 0 152 5. 50 SSW 47 98 11 1 0 0 186 4.67 SW 76 104 114 49 12 0 0 279 5 .74 WSW 68 95 20 7 0 0 190 5.50 W
77 7 0 0 0 134 4.73 WNW 50 46 61 14 0 0 0 121 5.10 NW 40 33 18 2 0 0 93 5.46 NNW 2128_________
Total 650 816 488 172 2 0 2128 Hours of Calm 1 Hours of Varying Wind Direction 0 Hours of Missing Data for All 79 Hours of No Stability Class 72 Total hours of observation 2208 TABLE 7 FOURTH QUARTER 2002 PAGE 80F8
TABLE 8 JOINT FREQUENCY DISTRIBUTION BY QUARTER FOR 2002
( BATCH RELEASES )
JOINT WIND FREQUENCY DISTRIBUTION BY STABILITY CLASS SITE: V. C. SUMMER Nuclear Station UNIT 1 Report Date : 03-02-27 Data Period : 2- 2-20 09:00 to 2- 2-20 16:00 Stability Class: A delta T/ delta z 61->10 m Delta T With Substitution Wind Sensor Height : 10 meter ++. Batch Release Times Only +++
Hours at Each Wind Direction and Speed Wind Wind Speed (miles/hour)
Direction Mean 0.75- <4 4- <8 8- <13 13- <19 19- 24 >24 Total' Speed N 0 0 0 0 0 0 0 0.00 NNE 0 0 0 0 0 0 0 0.00 NE 0 0 0 0 0 0 0 0.00 ENE 0 0 0 0 0 0 0 0.00 E 0 0 0 0 0 0 0 0.00 ESE 0 0 0 0 0 0 0 0.00 SE 0 0 0 0 0 0 0 0.00 SSE 0 0 0 0 0 0 0 0.00 S 0 0 0 0 0 0 0 0.00 SSW 0 0 0 0 0 0 0 0.00 SW 0 0 0 0 0 0 0 0.00 WSW 0 0 0 0 0 0 0 0.00 W 0 0 0 0 0 0 0 0.00 WNW 0 0 0 0 0 0 0 0.00 NW 0 0 0 0 0 0 0 0.00 NNW 0 0 0 0 0 0 0 0.00
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ s, Total 0 0 0 0 0 0 0 Hours of Calm 0 Hours of Varying Wind Direction : 0.
Hours of Missing Data : 0 Hours of Missing Data for All : 0 Hours of No Stability Class : 0 Total hours of observation : 8 TABLE 8 FIRST QUARTER 2002 PAGE 1OF8
JOINT WIND FREQUENCY DISTRIBUTION BY STABILITY CLASS SITE: V. C. SUMMER Nuclear Station UNIT 1 Report Date : 03-02-27 Data Period : 2- 2-20 09:00 to 2- 2-20 16:00 Stability Class: B delta T/ delta z 61->10 m Delta T With Substitution Wind Sensor Height : 10 meter .++Batch Release Times Only +++
Hours at Each Wind Direction and Speed Wind Wind Speed (miles/hour)
Direction Mean 0.75- <4 4- <8 8- <13 13- <19 19- 24 >24 Total' Speed N 0 0 0 0 0 0 0 0.00 NNE 0 0 0 0 0 0 0 0.00 NE 0 0 0 0 0 0 0 0.00 ENE 0 0 0 0 0 0 0 0.00 E 0 0 0 0 0 0 0 0.00 ESE 0 0 0 0 0 0 0 0.00 SE 0 0 0 0 0 0 0 0.00 SSE 0 0 0 0 0 0 0 0.00 S 0 0 0 0 0 0 0 0.00 SSW 0 0 0 0 0 0 0 0.00 SW 0 0 0 0 0 0 0 0.00 WSW 0 0 0 0 0 0 0 0.00 W 0 0 0 0 0 0 0 0.00 WNW 0 0 0 0 0 0 0 0.00 NW 0 0 0 0 0 0 0 0.00 NNW 0 0 0 0 0 0 0 0.00 Total 0 0 0 0 0 0 0 Hours of Calm : 0 Hours of Varying Wind Direction : 0 Hours of Missing Data : 0 Hours of Missing Data for All : 0 Hours of No Stability Class : 0 Total hours of observation 8 TABLE 8 FIRST QUARTER 2002 PAGE 2 OF 8
JOINT WIND FREQUENCY DISTRIBUTION BY STABILITY CLASS SITE: V. C. SUMMER Nuclear Station UNIT 1 Report Date : 03-02-27 Data Period : 2- 2-20 09:00 to 2- 2-20 16:00 Stability Class: C delta T/ delta z 61->10 m Delta T With Substitution Wind Sensor Height : 10 meter +++ Batch Release Times Only +++
Hours at Each Wind Direction and Speed Wind Wind Speed (miles/hour)
Direction Mean 0.75- <4 4- <8 8- <13 13- <19 19- 24 >24 Total' Speed N 0 0 0 0 0 0 0 0.00 NNE 0 0 0 0 0 0 0 0.00 NE 0 0 0 0 0 0 0 0.00 ENE 0 0 0 0 0 0 0 0.00 E 0 0 0 0 0 0 0 0.00 ESE 0 0 0 0 0 0 0 0.00 SE 0 0 0 0 0 0 0 0.00 SSE 0 0 0 0 0 0 0 0.00 S 0 0 0 0 0 0 0 0.00 SSW. 0 0 0 1 0 0 1 15.40 SW 0 0 0 1 0 0 1 14.96 WSW 0 0 0 0 0 0 0 0.00 W 0 0 0 0 0 0 0 0.00 WNW 0 0 0 0 0 0 0 0.00 NW 0 0 0 0 0 0 0 0.00 NNW 0 0 0 0 0 0 0 0.00 Total 0 0 0 2 0 0 2 Hours of Calm : 0 Hours of Varying Wind Direction : 0 Hours of Missing Data : 0 Hours of Missing Data for All : 0 Hours of No Stability Class : 0 Total hours of observation : 8 TABLE 8 FIRST QUARTER 2002 PAGE 3 OF 8
JOINT WIND FREQUENCY DISTRIBUTION BY STABILITY CLASS SITE: V. C. SUMMER Nuclear Station UNIT 1 Report Date : 03-02-27 Data Period : 2- 2-20 09:00 to 2- 2-20 16:00 Stability Class: D delta T/ delta z 61->10 m Delta T With Substitution Wind Sensor Height : 10 meter +++ Batch Release Times Only +++
Hours at Each Wind Direction and Speed Wind Wind Speed (miles/hour)
Direction Mean 0.75- <4 4- <8 8- <13 13- <19 19- 24 >24 Total' Speed N 0 0 0 0 0 0 0 0. 00 NNE 0 0 0 0 0 0 0 0. 00 NE 0 0 0 0 0 0 0 0. 00 ENE 0 0 0 0 0 0 0 0. 00 E 0 0 0 0 0 0 0 0. 00 ESE 0 0 0 0 0 0 0 0. 00 SE 0 0 0 0 0 0 0 0.00 SSE 0 0 0 0 0 0 0 0. 00 S 0 0 0 0 0 0 0 0. 00 SSW 0 0 1 0 0 0 1 11.20 SW 0 0 2 0 0 0 2 11.04 WSW 0 0 0 0 0 0 0 0.00 W 0 0 0 0 0 0 0 0.00 WNW 0 0 0 0 0 0 0 0.00 NW 0 0 0 0 0 0 0 0.00 NNW 0 0 0 0 0 0 0 0.00 Total 0 0 3 0 0 0 3 Hours of Calm : 0 Hours of Varying Wind Direction : 0 Hours of Missing Data : 0 Hours of Missing Data for All : 0 Hours of No Stability Class : 0 Total hours of observation : 8 TABLE 8 FIRST QUARTER 2002 PAGE 4 OF 8
JOINT WIND FREQUENCY DISTRIBUTION BY STABILITY CLASS SITE: V. C. SUMMER Nuclear Station UNIT 1 Report Date : 03-02-27 Data Period : 2- 2-20 09:00 to 2- 2-20 16:00 Stability Class: E delta T/ delta z 61->10 m Delta T With Substitution Wind Sensor Height : 10 meter +++ Batch Release Times Only +++
Hours at Each Wind Direction and Speed Wind Wind Speed (miles/hour)
Direction Mean 0.75- <4 4- <8 8- <13 13- <19 19- 24 >24 Total' Speed N 0 0 0 0 0 0 0 0.00 NNE 0 0 0 0 0 0 0 0.00 NE 0 0 0 0 0 0 0 0.00 ENE 0 0 0 0 0 0 0 0.00 E 0 0 0 0 0 0 0 0.00 ESE 0 0 0 0 0 0 0 0.00 SE 0 0 0 0 0 0 0 0.00 SSE 0 0 0 0 0 0 0 0.00 S 0 0 2 0 0 0 2 9.66 SSW 0 0 1 0 0 0 1 10.90 SW 0 0 0 0 0 0 0 0.00 WSW 0 0 0 0 0 0 0 0.00 W 0 0 0 0 0 0 0 0.00 WNW 0 0 0 0 0 0 0 0.00 NW 0 0 0 0 0 0 0 0.00 NNW 0 0 0 0 0 0 0 0.00 Total 0 0 3 0 0 0 3 Hours of Calm : 0 Hours of Varying Wind Direction : 0 Hours of Missing Data : 0 Hours of Missing Data for All : 0 Hours of No Stability Class : 0 Total hours of observation : 8 TABLE 8 FIRST QUARTER 2002 PAGE 50F8
JOINT WIND FREQUENCY DISTRIBUTION BY STABILITY CLASS SITE: V. C. SUMMER Nuclear Station UNIT 1 Report Date : 03-02-27 Data Period : 2- 2-20 09:00 to 2- 2-20 16:00 Stability Class: F delta T/ delta z 61->10 m Delta T With Substitution Wind Sensor Height : 10 meter +++ Batch Release Times Only +++
Hours at Each Wind Direction and Speed Wind Wind Speed (miles/hour)
Direction Mean 0.75- <4 4- <8 8- <13 13- <19 19- 24 >24 Total' Speed N 0 0 0 0 0 0 0 0.00 NNE 0 0 0 0 0 0 0 0.00 NE 0 0 0 0 0 0 0 0.00 ENE 0 0 0 0 0 0 0 0.00 E 0 0 0 0 0 0 0 0.00 ESE 0 0 0 0 0 0 0 0.00 SE 0 0 0 0 0 0 0 0.00 SSE 0 0 0 0 0 0 0 0.00 S 0 0 0 0 0 0 0 0.00 SSW 0 0 0 0 0 0 0 0.00 SW 0 0 0 0 0 0 0 0.00 WSW 0 0 0 0 0 0 0 0.00 W 0 0 0 0 0 0 0 0.00 WNW 0 0 0 0 0 0 0 0.00 NW 0 0 0 0 0 0 0 0.00 NNW 0 0 0 0 0 0 0 0.00 Total 0 0 0 0 0 0 0 Hours of Calm 0 Hours of Varying Wind Direction 0 Hours of Missing Data : 0 Hours of Missing Data for All 0 Hours of No Stability Class 0 Total hours of observation : 8 TABLE 8 FIRST QUARTER 2002 PAGE 6 OF 8
JOINT WIND FREQUENCY DISTRIBUTION BY STABILITY CLASS SITE: V. C. SUMMER Nuclear Station UNIT 1 Report Date : 03-02-27 Data Period : 2- 2-20 09:00 to 2- 2-20 16:00 Stability Class: G delta T/ delta z 61->10 m Delta T With Substitution Wind Sensor Height : 10 meter +++ Batch Release Times Only +++
Hours at Each Wind Direction and Speed Wind Wind Speed (miles/hour)
Direction Mean 0.75- <4 4- <8 8- <13 13- <19 19- 24 >24 Total' Speed N 0 0 0 0 0 0 0 0.00 NNE 0 0 0 0 0 0 0 0.00 NE 0 0 0 0 0 0 0 0.00 ENE 0 0 0 0 0 0 0 0.00 E 0 0 0 0 0 0 0 0.00 ESE 0 0 0 0 0 0 0 0.00 SE 0 0 0. 0 0 0 0 0.00 SSE 0 0 0 0 0 0 0 0.00 S 0 0 0 0 0 0 0 0.00 SSW 0 0 0 0 0 0 0 0.00 SW 0 0 0 0 0 0 0 0.00 WSW 0 0 0 0 0 0 0 0.00 W 0 0 0 0 0 0 0 0.00 WNW 0 0 0 0 0 0 0 0.00 NW 0 0 0 0 0 0 0 0.00 NNW 0 0 0 0 0 0 0 0..00 Total 0 0 0 0 0 0 0 Hours of Calm : 0 Hours of Varying Wind Direction 0 Hours of Missing Data : 0 Hours of Missing Data for All : 0 Hours of No Stability Class : 0 Total hours of observation 8 TABLE 8 FIRST QUARTER 2002 PAGE 7 OF 8
JOINT WIND FREQUENCY DISTRIBUTION BY STABILITY CLASS SITE: V. C. SUMMER Nuclear Station UNIT 1 Report Date : 03-02-27 Data Period : 2- 2-20 09:00 to 2- 2-20 16:00 Stability Class:ALL delta T/ delta z 61->10 m Delta T With Substitution Wind Sensor Height : 10 meter +++ Batch Release Times Only +++
Hours at Each Wind Direction and Speed Wind Wind Speed (miles/hour)
Direction Mean 0.75- <4 4- <8 8- <13 13- <19 19- 24 >24 Total' Speed N 0 0 0 0 0 0 0 0.00 NNE 0 0 0 0 0 0 0 0.00 NE 0 0 0 0 0 0 0 0.00 ENE 0 0 0 0 0 0 0 0.00 E 0 0 0 0 0 0 0 0.00 ESE 0 0 0 0 0 0 0 0.00 SE 0 0 0 0 0 0 0 0.00 SSE 0 0 0 0 0 0 0 0.00 S 0 0 2 0 0 0 2 9.66 SSW 0 0 2 1 0 0 3 12.50 SW 0 0 2 1 0 0 3 12.35 WSW 0 0 0 0 0 0 0 0.00 W 0 0 0 0 0 0 0 0.00 WNW 0 0 0 0 0 0 0 0.00 NW 0 0 0 0 0 0 0 0.00 NNW 0 0 0 0 0 0 0 0.00 Total 0 0 6 2 0 0 8 Hours of Calm : 0 Hours of Varying Wind Direction 0 Hours of Missing Data for All : 0 Hours of No Stability Class : 0 Total hours of observation : 8 TABLE 8 FIRST QUARTER 2002 PAGE 8OF 8
JOINT WIND FREQUENCY DISTRIBUTION BY STABILITY CLASS SITE: V. C. SUMMER Nuclear Station UNIT 1 Report Date : 03-02-27 Data Period : 2- 2-25 19:00 to 2- 2-25 20:00 Stability Class: A delta T/ delta z 61->10 m Delta T With Substitution Wind Sensor Height : 10 meter +++ Batch Release Times Only +++
Hours at Each Wind Direction and Speed W i n d _ _ _ _ _ _ _ _ _ _
W i _
n d_ _ _ e_ e _
d_ _ i
_ le _ s/hour)_ _ __Sp _ __(m _ _ _ _ _
Wind Wind Speed (miles/hour)
Direction Mean 0.75- <4 4- <8 8- <13 13- <19 19- 24 >24 Total' Speed N 0 0 0 0 0.00 NNE 0 0o 0 0o 0 0 0. 00 NE 0o 0 0 0 0 0. 00 ENE 0 0 0 0 0. 00 E 0 0 0 0 0.00 0 To0 0 0 0 0. 00 ESE 0 0 0 0 0 0 0 0.00 SE 0 0 0o 0 0 0 0. 00 SSE 0 0 To0 0 0 0 0 0 0. 00 S 0 0 0o 0 0 0 0 0. 00 SSW 0 0 0 0 0 0 0. 00 SW 0 0 0
0 0 0 0 0.00 WSW 0 0 0 0 0 0 0. 00 W 0 WNW 0 0 0 0 0. 00 NW 0 0 0 0 0. 00 NNW 0 0 0 0 0. 00 Total 0 0 0 0 0 0 0 Hours of Calm :
Hours of Varying Wind Direction :
Hours of Missing Data :
Hours of Missing Data for All :
Hours of No Stability Class :
Total hours of observation :2 TABLE 8 FIRST QUARTER 2002 PAGE lOF8
JOINT WIND FREQUENCY DISTRIBUTION BY STABILITY CLASS SITE: V. C. SUMMER Nuclear Station UNIT 1 Report Date : 03-02-27 Data Period : 2- 2-25 19:00 to 2- 2-25 20:00 Stability Class: B delta T/ delta z 61->10 m Delta T With Substitution Wind Sensor Height : 10 meter +++ Batch Release Times Only +++
Hours at Each Wind Direction and Speed Wind Wind Speed (miles/hour)
Direction Mean 0.75- <4 4- <8 8- <13 13- <19 19- 24 >24 Total' Speed N 0 0 0 0 0 0 0 0.00 NNE 0 0 0 0 0 0 0 0.00 NE 0 0 0 0 0 0 0 0.00 ENE 0 0 0 0 0 0 0 0.00 E 0 0 0 0 0 0 0 0.00 ESE 0 0 0 0 0 0 0 0.00 SE 0 0 0 0 0 0 0 0.00 SSE 0 0 0 0 0 0 0 0.00 S 0 0 0 0 0 0 0 0.00 SSW 0 0 0 0 0 0 0 0.00 SW 0 0 0 0 0 0 0 0.00 WSW 0 0 0 0 0 0 0 0.00 W 0 0 0 0 0 0 0 0.00 WNW 0 0 0 0 0 0 0 0.00 NW 0 0 0 0 0 0 0 0.00 NNW 0 0 0 0 0 0 0 0.00 Total 0 0 0 0 0 0 0 Hours of Calm : 0 Hours of Varying Wind Direction : 0 Hours of Missing Data : 0 Hours of Missing Data for All : 0 Hours of No Stability Class : 0 Total hours of observation : 2 TABLE 8 FIRST QUARTER 2002 PAGE 2 OF8
JOINT WIND FREQUENCY DISTRIBUTION BY STABILITY CLASS SITE: V. C. SUMMER Nuclear Station UNIT 1 Report Date : 03-02-27 Data Period : 2- 2-25 19:00 to 2- 2-25 20:00 Stability Class: C delta T/ delta z 61->10 m Delta T With Substitution Wind Sensor Height : 10 meter +++ Batch Release Times Only +++
Hours at Each Wind Direction and Speed Wind Wind Speed (miles/hour)
Direction Mean I 0.75- <4 4- <8 8- <13 13- <19 19- 24 >24 Total Speea N 0 0 0 0 0 0 0 0.00 0 0 0 0 0 0 0 0.00 NE 0 0 0 0 0 0 0 0.00 ENE 0 0 0 0 0 0 0 0.00 E 0 0 0 0 0 0 0 0.00 ESE 0 0 0 0 0 0 0 0.00 SE 0 0 0 0 0 0 0 0.00 SSE 0 0 0 0 0 0 0 0.00 S 0 0 0 0 0 0 0 0.00 SSW 0 0 0 0 0 0 0 0.00 SW 0 0 0 0 0 0 0 0.00 WSW 0 0 0 0 0 0 0 0.00 W 0 0 0 0 0 0 0 0.00 WNW 0 0 0 0 0 0 0 0.00 0 0 0 0 0 0 0 0.00 NW 0 NNW 0 0 0 0 0 0 0.00
____________0_
Tota___________________0______0______0_______0__
Total ° ° 0 0 0 Hours of Calm 0 Hours of Varying Wind Direction 0 Hours of Missing Data 0 Hours of Missing Data for All 0 Hours of No Stability Class 0 Total hours of observation 2 TABLE 8 FIRST QUARTER 2002 PAGE 3 OF 8
JOINT WIND FREQUENCY DISTRIBUTION BY STABILITY CLASS SITE: V. C. SUMMER Nuclear Station UNIT 1 Report Date : 03-02-27 Data Period : 2- 2-25 19:00 to 2- 2-25 20:00 Stability Class: D delta T/ delta z 61->10 m Delta T With Substitution Wind Sensor Height : 10 meter +++ Batch Release Times Only +++
Hours at Each Wind Direction and Speed Wind__________Wind__________Speed___________(miles/hour)____________________
Wind Wind Speed (miles/hour)
Direction Mean 0.75- <4 4- <8 8- <13 13- <19 19- 24 >24 Total' Speed N 0 0 0 0 0 0 0 0.00 NNE 0 0 0 0 0 0 0 0.00 NE 0 0 0 0 0 0 0 0.00 ENE 0 0 0 0 0 0 0 0.00 E 0 0 0 0 0 0 0 0.00 ESE 0 0 0 0 0 0 0 0.00 SE 0 0 0 0 0 0 0 0.00 SSE 0 0 0 0 0 0 0 0.00 S 0 0 0 0 0 0 0 0.00 SSW 0 0 0 0 0 0 0 0.00 SW 0 0 0 0 0 0 0 0.00 WSW 0 0 0 0 0 0 0 0.00 W 0 0 0 0 0 0 0 0.00 WNW 0 0 0 0 0 0 0 0.00 NW 0 0 0 0 0 0 0 0.00 NNW 0 0 0 0 0 0 0 0.00 Tota____________________0_______0_______0_______0_______0_______0_______0___
Total 00 Hours of Calm I 0 Hours of Varying Wind Direction 0 Hours of Missing Data 0 Hours of Missing Data for All 0 Hours of No Stability Class 0 Total hours of observation 2 TABLE 8 FIRST QUARTER 2002 PAGE 4 OF 8
JOINT WIND FREQUENCY DISTRIBUTION BY STABILITY CLASS SITE: V. C. SUMMER Nuclear Station UNIT 1 Report Date : 03-02-27 Data Period : 2- 2-25 19:00 to 2- 2-25 20:00 Stability Class: E delta T/ delta z 61->10 m Delta T With Substitution Wind Sensor Height : 10 meter +++ Batch Release Times Only +++
Hours at Each Wind Direction and Speed Wind Wind Speed (miles/hour)
Direction Mean 0.75- <4 4- <8 8- <13 13- <19 19- 24 >24 Total' Speed N 0 0 0 0 0 0 0 0.00 NNE 0 0 0 0 0 0 0 0.00 NE 0 0 0 0 0 0 0 0.00 ENE 0 0 0 0 0 0 0 0.00 E 0 0 0 0 0 0 0 0.00 ESE 0 0 0 0 0 0 0 0.00 SE 0 0 0 0 0 0 0 0.00 SSE 0 0 0 0 0 0 0 0.00 S 0 0 0 0 0 0 0 0.00 SSW 1 0 0 0 0 0 1 3.78 SW 0 1 0 0 0 0 1 4.22 WSW 0 0 0 0 0 0 0 0.00 W 0 0 0 0 0 0 0 0.00 WNW 0 0 0 0 0 0 0 0.00 NW 0 0 0 0 0 0 0 0.00 NNW 0 0 0 0 0 0 0 0.00 Total 1 1 0 0 0 0 2 Hours of Calm : 0 Hours of Varying Wind Direction : 0 Hours of Missing Data : 0 Hours of Missing Data for All : 0 Hours of No Stability Class : 0 Total hours of observation : 2 TABLE 8 FIRST QUARTER 2002 PAGE 5OF8
JOINT WIND FREQUENCY DISTRIBUTION BY STABILITY CLASS SITE: V. C. SUMMER Nuclear Station UNIT 1 Report Date : 03-02-27 Data Period : 2- 2-25 19:00 to 2- 2-25 20:00 Stability Class: F delta T/ delta z 61->10 m Delta T With Substitution Wind Sensor Height : 10 meter +++ Batch Release Times Only +++
Hours at Each Wind Direction and Speed Wind Wind Speed (miles/hour)
Direction Mean 0.75- <4 4- <8 8- <13 13- <19 19- 24 >24 Total' Speed N 0 0 0 0 0 0 0 0.00 NNE 0 0 0 0 0 0 0 0.00 NE 0 0 0 0 0 0 0 0.00 ENE 0 0 0 0 0 0 0 0.00 E 0 0 0 0 0 0 0 0.00 ESE 0 0 0 0 0 0 0 0.00 SE 0 0 0 0 0 0 0 0.00 SSE 0 0 0 0 0 0 0 0.00 S 0 0 0 0 0 0 0 0.00 SSW 0 0 0 0 0 0 0 0.00 SW 0 0 0 0 0 0 0 0.00 WSW 0 0 0 0 0 0 0 0.00 W 0 0 0 0 0 0 0 0.00 WNW 0 0 0 0 0 0 0 0.00 NW 0 0 0 0 0 0 0 0.00 NNW 0 0 0 0 0 0 0 0.00 Total 0 0 0 0 0 0 0 Hours of Calm : 0 Hours of Varying Wind Direction 0 Hours of Missing Data : 0 Hours of Missing Data for All : 0 Hours of No Stability Class : 0 Total hours of observation : 2 TABLE 8 FIRST QUARTER 2002 PAGE 60F8
JOINT WIND FREQUENCY DISTRIBUTION BY STABILITY CLASS SITE: V. C. SUMMER Nuclear Station UNIT 1 Report Date : 03-02-27 Data Period : 2- 2-25 19:00 to 2- 2-25 20:00 Stability Class: G delta T/ delta z 61->10 m Delta T With Substitution Wind Sensor Height : 10 meter +++ Batch Release Times Only +++
Hours at Each Wind Direction and Speed Wind__________Wind__________Speed___________(miles/hour)____________________
Wind Wind Speed (miles/hour)
Direction Mean 0.75- <4 4- <8 8- <13 13- <19 19- 24 >24 Total' Speed N 0 0 0 0 0 0 0 0.00 NNE 0 0 0 0 0 0 0 0.00 NE 0 0 0 0 0 0 0 0.00 ENE 0 0 0 0 0 0 0 0.00 E 0 0 0 0 0 0 0.00 ESE 0 0 0 0 0 0 0 0.00 SE 0 0 0 0 0 0 0 0.00 SSE 0 0 0 0 0 0 0 0.00 S 0 0 0 0 0 0 0 0.00 SSW 0 0 0 0 0 0 0 0.00 SW 0 0 0 0 0 0 0 0.00 WSW 0 0 0 0 0 0 0 0.00 W 0 0 0 0 0 0 0 0.00 WNW 0 0 0 0 0 0 0 0.00 NW 0 0 0 0 0 0 0 0.00 NNW 0 0 0 0 0 0 0 0.00 Total 0 0 0 0 0 0 0 Hours of Calm 0 Hours of Varying Wind Direction 0 Hours of Missing Data : 0 Hours of Missing Data for All 0 Hours of No Stability Class : 0 Total hours of observation 1: 2 TABLE 8 FIRST QUARTER 2002 PAGE 7 OF 8
JOINT WIND FREQUENCY DISTRIBUTION BY STABILITY CLASS SITE: V. C. SUMMER Nuclear Station UNIT 1 Report Date : 03-02-27 Data Period : 2- 2-25 19:00 to 2- 2-25 20:00 Stability Class:ALL delta T/ delta z 61->10 m Delta T With Substitution Wind Sensor Height : 10 meter +++ Batch Release Times Only +++
Hours at Each Wind Direction and Speed Wind Wind Speed (miles/hour)
Direction Mean 0.75- <4 4- <8 8- <13 13- <19 19- 24 >24 Total' Speed N 0 0 0 0 0 0 0 0.00 NNE 0 0 0 0 0 0 0 0.00 NE 0 0 0 0 0 0 0 0.00 ENE 0 0 0 0 0 0 0 0.00 E 0 0 0 0 0 0 0 0.00 ESE 0 0 0 0 0 0 0 0.00 SE 0 0 0 0 0 0 0 0.00 SSE 0 0 0 0 0 0 0 0.00 S 0 0 0 0 0 0 0 0.00 SSW 1 0 0 0 0 0 1 3.78 SW 0 1 0 0 0 0 1 4.22 WSW 0 0 0 0 0 0 0 0.00 W 0 0 0 0 0 0 0 0.00 WNW 0 0 0 0 0 0 0 0.00 NW 0 0 0 0 0 0 0 0.00 NNW 0 0 0 0 0 0 0 0.00 Total 1 1 0 0 0 0 2 Hours of Calm : 0 Hours of Varying Wind Direction : 0 Hours of Missing Data for All : 0 Hours of No Stability Class : 0 Total hours of observation 2 TABLE 8 FIRST QUARTER 2002 PAGE 8 OF8
SITE: V. C. SUMMER Nuclear Station UNIT 1
Report Date : 03-02-27 Data Period : 2- 6-11 13:00 Stability Class: A to 2- 6-11 18:00 delta T/ delta z 61->10 m Delta Wind Sensor Height : 10 meter T With Substitution
+++ Batch Release Times Only +++
Hours at Each Wind Direction and Speed Wind________________________________________________________________________
Wind Wind Speed (miles/hour)
Direction 0.75- <4 4- <8 8- <13 13- <19 Mean 19- 24 Av F514. - I Q_ A-
________ -------- ________- 13--- ---
13- _ suLwl-C6 0frpeea N 0 O E O 0 0 0 0 0 0 0 0 0.00 NE 0 0 0 0 0.00 0 0 0 ENE 0 0 0 0 0 0 0 0.00 E 0 0 0 0 0.00 ESE 0 0 0 0 0 0 0 0 0 0 0.00 SE 0 0 0 0 0.00 SSE 0 0 0 0 0 0 0 0 0.00 S 0 0 0 0 0.00 SSW 0 0 0 0 0 0.00 0 0 0 0 0 SW 0 0 0 0 0 0 0.00 WSW 0 0 0 0 0 0 0 0 0.00 W 0 0 0 0 0.00 WNW 0 0 0 0 0 0.00 0 0 0 0 0 NW 0 0 0 0 0.00 000 NNW 0 0 0 0 0 0 0.00 0 0 0.00 Total 0 0 0 0 0
Hours of Calm Hours of Varying Wind Direction 0 Hours of Missing Data *0 Hours of Missing Data for All 4 Hours of No Stability Class : 6 Total hours of observation 6
TABLE 8 SECOND QUARTER 2002 PAGE 1 OF 8
JOINT WIND FREQUENCY DISTRIBUTION BY STABILITY CLASS SITE: V. C. SUMMER Nuclear Station UNIT 1 Report Date : 03-02-27 Data Period : 2- 6-11 13:00 to 2- 6-11 18:00 Stability Class: B delta T/ delta z 61->10 m Delta T With Substitution Wind Sensor Height : 10 meter +++ Batch Release Times Only +++
Hours at Each Wind Direction and Speed Wind Wind Speed (miles/hour)
Direction Mean 0.75- <4 4- <8 8- <13 13- <19 19- 24 >24 Total' Speed N 0 0 0 0 0 0 0 0.00 NNE 0 0 0 0 0 0 0 0.00 NE 0 0 0 0 0 0 0 0.00 ENE 0 0 0 0 0 0 0 0.00 E 0 0 0 0 0 0 0 0.00 ESE 0 0 0 0 0 0 0 0.00 SE 0 0 0 0 0 0 0 0.00 SSE 0 0 0 0 0 0 0 0.00 S 0 0 0 0 0 0 0 0.00 SSW 0 0 0 0 0 0 0 0.00 SW 0 0 0 0 0 0 0 0.00 WSW 0 0 0 0 0 0 0 0.00 W 0 0 0 0 0 0 0 0.00 WNW 0 0 0 0 0 0 0 0.00 NW 0 0 0 0 0 0 0 0.00 NNW 0 0 0 0 0 0 0 0.00 Total 0 0 0 0 0 0 0 Hours of Calm : 0 Hours of Varying Wind Direction : -0 Hours of Missing Data : 0 Hours of Missing Data for All 6 Hours of No Stability Class : 0 Total hours of observation 6 TABLE 8 SECOND QUARTER 2002 PAGE 20F8
JOINT WIND FREQUENCY DISTRIBUTION BY STABILITY CLASS SITE: V. C. SUMMER Nuclear Station-UNIT 1 Report Date : 03-02-27 Data Period : 2- 6-11 13:00 to 2- 6-11 18:00 Stability Class: C delta T/ delta z 61->10 m Delta T With Substitution Wind Sensor Height : 10 meter +++ Batch Release Times Only ++.
Hours at Each Wind Direction and Speed Wind Wind Speed (miles/hour)
Direction Mean 0.75- <4 4- <8 8- <13 13- <19 19- 24 >24 Total' Speed N 0 0 0 0 0 0 0 0.00 NNE 0 0 0 0 0 0 0 0.00 NE 0 0 0 0 0 0 0 0.00 ENE 0 0 0 0 0 0 0 0.00 E 0 0 0 0 0 0 0 0.00 ESE 0 0 0 0 0 0 0 0.00 SE 0 0 0 0 0 0 0 0.00 SSE 0 0 0 0 0 0 0 0.00 S 0 0 0 0 0 0 0 0.00 SSW 0 0 0 0 0 0 0 0.00 SW 0 0 0 0 0 0 0 0.00 WSW 0 0 0 0 0 0 0 0.00 W 0 0 0 0 0 0 0 0.00 WNW 0 0 0 0 0 0 0 0.00 NW 0 0 0 0 0 0 0 0.00 NNW 0 0 0 0 0 0 0 0.00 Total 0 0 0 0 0 0 0 Hours of Calm : 0 Hours of Varying Wind Direction : 0 Hours of Missing Data : 2 Hours of Missing Data for All : 6 Hours of No Stability Class : 0 Total hours of observation : 6 TABLE 8 SECOND QUARTER 2002 PAGE 30F8
JOINT WIND FREQUENCY DISTRIBUTION BY STABILITY CLASS SITE: V. C. SUMMER Nuclear Station UNIT 1 Report Date : 03-02-27 Data Period : 2- 6-11 13:00 to 2- 6-11 18:00 Stability Class: D delta T/ delta z 61->10 m Delta T With Substitution Wind Sensor Height : 10 meter +++ Batch Release Times Only +++
Hours at Each Wind Direction and Speed Wind Wind Speed (miles/hour)
Direction 0.75- <4 4- <8 Mean 8- <13 13- <19 19- 24 >24 Total' Speed N 0 0 0. 0 NNE 0 0 0 0.00 0 0 0 0 0 0 0.00 NE 0 0 0
0 0 0 0 0 0.00 ENE 0 0 0 0 E 0 0 0. 0.00 0 0 0 0 0 0 0.00 ESE 0 0 0
0 0 0 0 0 0.00 SE 0 0 0 0 0 SSE 0 0 0.00 0 0 0 0 0 0 0.00 S 0 0 0 0 0 0 0 0 0.00 SSW 0 0 0 0 SW 0 0 0 0.00 0 0 0 0 0 0 0.00 WSW 0 0 0 0 0 0 0 0 0.00 W 0 0 0 WNW 0 0 0 0 0.00 0 0 0 0 0, 0 0.00 NW 0 0 0 0 0 0 0 0 0.00 NNW 0 0 0 0 0 0 0.00 0
Total 0 0 0 0 0 0 0 Hours of Calm : 0 Hours of Varying Wind Direction 0 Hours of Missing Data : 0 Hours of Missing Data for All 6 Hours of No Stability Class : 0 Total hours of observation 6 TABLE 8 SECOND QUARTER 2002 PAGE 4 OF 8
JOINT WIND FREQUENCY DISTRIBUTION BY STABILITY CLASS SITE: V. C. SUMMER Nuclear Station UNIT 1 Report Date : 03-02-27 Data Period : 2- 6-11 13:00 to 2- 6-11 18:00 Stability Class: E delta T/ delta z 61->10 m Delta T With Substitution Wind Sensor Height : 10 meter +++ Batch Release Times Only ++.
Hours at Each Wind Direction and Speed Wind Wind Speed (miles/hour)
Direction 0.75- <4 4- <8 8- <13 mean 13- <19 19- 24 >24 Total' Speed
_N__
__ _ _ _ _0__
_ _ _ _ _ _ _ _ _ _0_
__ _ _ _ _0_ _ ________
0_ 0____
N 0 0 0 0 0 NNE 0 0 0.00 0 0 0 0 0 0 NE 0 0 0.00 0 0 0 0 0 0 ENE 0 0.00 0 0 0 0 0 0.00 E 0 0 0 0 0 0 0 0 0.00 ESE 0 0 0 0 0 SE 0 0 0.00 0 0 0 0 0 SSE 0 0 0.00 0 0 0 0 0 S 0 0 0.00 0 0 0 0 0 SSW 0 0 0.00 0 0 0 0 0 0 SW 0 0 0.00 0 0 0 0 0 WSW o 0 0 0.00 o O O 0 W 0 0 0 0.00 0 0 0 0 WNW 0 0 0 0.00 0 0 0 0 NW 0 0 0 0.00 0 0 0 0 NNW 0 0 0 0 0 0 0.00 0
Total 0 0 0 0 0 0 0 Hours of Calm :
Hours of Varying Wind Direction :
Hours of Missing Data :
Hours of Missing Data for All :6 Hours of No Stability Class :
Total hours of observation :6 TABLE 8 SECOND QUARTER 2002 PAGE 5 OF 8
JOINT WIND FREQUENCY DISTRIBUTION BY STABILITY CLASS SITE: V. C. SUMMER Nuclear Station UNIT 1 Report Date : 03-02-27 Data Period : 2- 6-11 13:00 to 2- 6-11 18:00 Stability Class: F delta T/ delta z 61->10 m Delta T With Substitution Wind Sensor Height : 10 meter +++ Batch Release Times Only +++
Hours at Each Wind Direction and Speed Wind Wind Speed (miles/hour)
Direction --
0.75- <4 4- <8 8- <13 13- <19 19- 24 >24 Total' Speed N 0 0 0 0 NNE 0 0 0 0 .00 0 0 0 0 0. 00 NE 0 0
0 0 0 0 0 0. 00 ENE 0 0
0 0 0 0 0. 00 E 0 0 0 0 0 0 0 0. 00 ESE 0 0
0 0 0 0 SE 0 0 0 0. 00 0 0 0 0 0 0. 00 SSE 0 0 0 0 0 0 0 0. 00 S 0 0 0 0 0 0 0 0. 00 SSW 0 0
0 0 0 0 0 SW 0 0 0. 00 0 0 0 0 WSW 0 0 0 0. 00 0 0 0 0 0 W 0 0 0. 00 0 0 0 0 0 0 0. 00 WNW 0 0 0 0 0 0 0. 00 NW 0 0 0 0 0 0 0. 00 NNW 0 0 0 0
_________ 0 0. 00 Total 0 0 0 0 0 0 . 0 Hours of Calm
~:Hours of Varying Wind Direction Hours of Missing Data : O Hours of Missing Data for All- :6 Hours of No Stability Class :
Total hours of observation :6 TABLE 8 SECOND QUARTER 2002 PAGE 6OF 8
JOINT WIND FREQUENCY DISTRIBUTION BY STABILITY CLASS SITE: V. C. SUMMER Nuclear Station UNIT 1 Report Date : 03-02-27 Data Period : 2- 6-11 13:00 to 2- 6-11 18:00 Stability Class: G delta T/ delta z 61->10 m Delta T With Substitution Wind Sensor Height : 10 meter +++ Batch Release Times Only +++
Hours at Each Wind Direction and Speed Wind Wind Speed (miles/hour)
Direction 0.75- <4 4- <8 Mean 8- <13 13- <19 19- 24 >24 Total' Speed N 0 0 NNE 0 0 0 0 0 0 0.00 0 0 NE 0 0 0 0 0 0.00 0 0 0 0 0 ENE 0 0 0 0.00 E 0 0 0 0 0 0 0.00 0 0 0 0 0 ESE 0 0 0 0.00 SE 0 0 0 0 0 0 0.00 0 0 0 0 0 SSE 0 0 0 0.00 S 0 0 0 0 0 0 0.00 0 0 0 0 0 SSW 0 0 0 0.00 SW 0 0 0 0 0 0 0.00 0 0 0 0 0 WSW 0 0 0 0.00 W 0 0 0 0 0 0.00 0 0 0 WNW 0 0 0 0 0 0.00 0 0 0 0 0 NW 0 0 0 0.00 NNW 0 0 0 0 0 0.00 0 0 0
_ _ _ _ _ __ _ 0 0 0 0 0.00 Total 0 0 0 0 0 0 0 Hours of Calm 0 Hours of Varying Wind Direction 0 Hours of Missing Data ' 0 Hours of Missing Data for All 6 Hours of No Stability Class 0 Total hours of observation 6 TABLE 8 SECOND QUARTER 2002 PAGE 70F8
JOINT WIND FREQUENCY DISTRIBUTION BY STABILITY CLASS SITE: V. C. SUMMER Nuclear Station UNIT 1 Report Date : 03-02-27 Data Period : 2- 6-11 13:00 to 2- 6-11 Stability Class:ALL delta T/ delta z 61->10 m 18:00 Wind Sensor Height : 10 meter Delta T With Substitution
+++ Batch Release Times Hours at Each Wind Direction Only +++
and Speed Wind Wind Speed (miles/hour)
Direction 0.75- <4 4- <8 8- <13 13- <19 19- 24 >24 Totl'M~ean Total'
_- - - - - - - - - _ _ _ _ _ _ _ _ _ _ _ Speed N 0 0 NNE 0 0 0 0 0 0 0 0 0.00 NE 0 0 0 0 0 0 0 0 0.00 ENE 0 0 0 0 0.00 E 0 0 0 0 0 0 0 0.00 ESE 0 0 0 0 0 0 0 0 0 0 0.00 SE 0 0 0 0 SSE 0 0 0 0.00 0 0 0 0 0.00 S 0 0
0 0 0 0 0.00 SSW 0 0 0 0 0 SW 0 0 0 0 0.00 0 0 0 0 0 0.00 WSW 0 0 0 0 0 0 0 0.00 W 0 0 0 0 0 0.00 WNW 0 0 0 0 0 0 0 0 0 0 0.00 NW 0 0 0 0 0.00 NNW 0 0 0 0 0 0 0 0 0 0.00 0
0 0.00 Total 0 0 0 0 0 0 0
Hours of Calm Hours of Varying Wind Direction 0 Hours of Missing Data for All 0 Hours of No Stability Class 6 Total hours of observation 0 6
TABLE 8 SECOND QUARTER 2002 PAGE 80F8
JOINT WIND FREQUENCY DISTRIBUTION BY STABILITY CLASS SITE: V. C. SUMMER Nuclear Station UNIT 1 Report Date : 03-02-27 Data Period : 2- 6-17 11:00 to 2- 6-17 15:00 Stability Class: A delta T/ delta z 61->10 m Delta T With Substitution Wind Sensor Height : 10 meter +++ Batch Release Times Only +++
Hours at Each Wind Direction and Speed Wind Wind Speed (miles/hour)
Direction 0.75- <4 4- <8 Mean 8- <13 13- <19 19- 24 >24 Total' Speed
_ _ _ _ _ _ _ _ _ _ _ 0_0_0_0 N__ ______ _______ _______ _____ 0 _ _ _ _ _ 0__
N 0 0 0 0 0___0__00_
0 0 0 0.00 NNE 0 0 0 0 0 0 NE 0 0.00 0 0 0 0 0 0 0 ENE 0 0.00 0 0 0 0 0 0 0.00 E 0 0 0 0 0 0 ESE 0 0.00 0 0 0 0 0 0 0 SE 0 0.00 0 0 0 0 0 0 0.00 SSE 0 0 0 0 0 0 S 0 0.00 0 0 0 0 0 SSW 0 0 0.00 0 0 0 0 0 0 0 0.00 WSW 0 0 0 0 0 0.00 0 0 W 0 0 0.00 0 0 0 0 0 0 0.00 WNW 0 0 0 0 0 0 NW 0 0 0.00 0 0 0 0 0 0 0. 00 NNW 0 0 0 0 0 0 O 0. 00 Total 0 0 0_________0_________0____
0 0 O O O :
Hours of Calm 0 Hours of Varying Wind Direction 0 Hours of Missing Data 4 Hours of Missing Data for All 5 Hours of No Stability Class 0 Total hours of observation 5 TABLE 8 SECOND QUARTER 2002 PAGE 1 OF 8
JOINT WIND FREQUENCY DISTRIBUTION BY STABILITY CLASS SITE: V. C. SUMMER Nuclear Station UNIT 1 Report Date : 03-02-27 Data Period : 2- 6-17 11:00 to 2- 6-17 15:00 Stability Class: B delta T/ delta z 61->10 m Delta T With Substitution Wind Sensor Height : 10 meter +++ Batch Release Times Only +++
Hours at Each Wind Direction and Speed Wind Wind Speed (miles/hour)
Direction Mean 0.75- <4 4- <8 8- <13 13- <19 19- 24 >24 Total' Speed N 0 0 0 0 0 0 0 0.00 NNE 0 0 0 0 0 0 0 0.00 NE 0 0 0 0 0 0 0 0.00 ENE 0 0 0 0 0 0 0 0.00 E 0 0 0 0 0 0 0 0.00 ESE 0 0 0 0 0 0 0 0.00 SE 0 0 0 0 0 0 0 0.00 SSE 0 0 0 0 0 0 0 0.00 S 0 0 0 0 0 0 0 0.00 SSW 0 0 0 0 0 0 0 0.00 SW 0 0 0 0 0 0 0 0.00 WSW 0 0 0 0 0 0 0 0.00 W 0 0 0 0 0 0 0 0.00 WNW 0 0 0 0 0 0 0 0.00 NW 0 0 0 0 0 0 0 0.00 NNW 0 0 0 0 0 0 0 0.00 Total 0 0 0 0 0 0 0 Hours of Calm : 0 Hours of Varying Wind Direction : 0 Hours of Missing Data 1 I
Hours of Missing Data for All : 5 Hours of No Stability Class : 0 Total hours of observation : 5 TABLE 8 SECOND QUARTER 2002 PAGE 20F8
JOINT WIND FREQUENCY DISTRIBUTION BY STABILITY CLASS SITE: V. C. SUMMER Nuclear Station UNIT 1 Report Date : 03-02-27 Data Period : 2- 6-17 11:00 to 2- 6-17 15:00 Stability Class: C delta T/ delta z 61->10 m Delta T With Substitution Wind Sensor Height 10 meter +++ Batch Release Times Only +++
Hours at Each Wind Direction and Speed Wind Wind Speed (miles/hour)
Direction 0.75- <4 4- <8 Mean 8- <13 13- <19 19- 24 >24 Total' Speed
_ _ _ _ _ _ _ _ _ _ _ _0_
N_ _ _ _ _ _ _ 0_
__________ 0 _ _0__ _ _ _ _ _ _0__ _ _ _ _ __
0_
N 0 0 0 0 0 0 0 0.00 NNE 0 0 0 0 0 0 0 0.00 NE 0 0 0 0 0 0 0 0.00 ENE 0 0 0 0 0 0 E 0 0.00 0 0 0 0 0 0 0 0.00 ESE 0 0 0 0 0 0 0 0.00 SE 0 0 0 0 0 0 0 0.00 SSE 0 0 0 0 0 0 0 0.00 S 0 0 0 0 0 0 SSW 0 0.00 0 0 0 0 0 0 0 0.00 SW 0 0 0 0 0 0 0 0.00 WSW 0 0 0 0 0 0 W
0 0.00 0 0 0 0 0 0 0 0.00 WNW 0 0 0 0 0 0 0 0.00 NW 0 0 0 0 0 0 0 0.00 NNW 0 0 0 0 0 0 0
______ ________ _____________ _____________ 0. 00
_ _0_.00__
Total 0o 0 0 0 0 0 0 Hours of Calm 0o Hours of Varying Wind Direction-: - 0 Hours of Missing Data : 0o Hours of Missing Data for All : 5 Hours of No Stability Class 0 Total hours of observation 5 TABLE 8 SECOND QUARTER 2002 PAGE 3OF 8
JOINT WIND FREQUENCY DISTRIBUTION BY STABILITY CLASS.
SITE: V. C. SUMMER Nuclear Station UNIT 1 Report Date : 03-02-27 Data Period : 2- 6-17 11:00 to 2- 6-17 15:00 Stability Class: D delta T/ delta.z. 61->10 m Delta T With Substitution Wind Sensor Height : 10 meter +++ Batch Release Times Only +++
Hours at Each Wind Direction and Speed Wind Wind Speed (miles/hour)
Direction 0.75- <4 4- <8 8- <13 13- <19 19- 24 >24 Total' Speed N 0 0 0 0 0 0. 00 0
NNE 0 0 0 0 0 0. 00 NE 0 0 0 0 0 0 0 0. 00 ENE D 0 0 0 0 0 0. 00 0
E 0 0 0 0 0 0 0. 00 ESE 0 0 0 0 0 0. 00 SE 0 0 0 0 0 0 0 0 0. 00 0
SSE 0 0 0 0 0 0 0. 00 S 0 0 0 0 0 0 0 0. 00 SSW 0 0 0 0 0 0 0 0. 00 0
SW 0 0 0 0 0 0 0 0.00 WSW 0 0 0 0 0 0 0. 00 W 0 0 0 0 0 0 0. 00 WNW 0 0 0 0 0 0 0. 00 NW 0 0 0 0 0 0 0. 00 NNW 0 0 0 0 0 0 0. 00
_____________ 0_________0_________0________0_________0_________0___
Total 0 0 0 0 0 0 0 Hours of Calm :
Hours of Varying Wind Direction :
Hours of Missing Data :
Hours of Missing Data for All :5 Hours of No Stability Class :
Total hours of observation :5 TABLE 8 SECOND QUARTER 2002 PAGE 4OF 8
JOINT WIND FREQUENCY DISTRIBUTION BY STABILITY CLASS SITE: V. C. SUMMER Nuclear Station UNIT 1 Report Date : 03-02-27 Data Period : 2- 6-17 11:00 to 2- 6-17 15:00 Stability Class: E delta T/ delta z 61->10 m Delta T With Substitution.
Wind Sensor Height : 10 meter +++ Batch Release Times Only +++
Hours at Each Wind Direction and Speed Wind Wind Speed (miles/hour)
Direction Mn-s 0.75- <4 4- <8 8- <13 13- <19 19- 24 >24 Total' Speed N__ _ 0__ _ _ _ _ _ _ _ _ 0__
_ _______ 0__ _ _ _ _ _ _ _______
0_ 0__ _ _ _ _ _ _0 _ _ _
N 0 0 0 0 0 0 0 0.00 NNE 0 0 0 0 0 0 0 0.00 NE 0 0 0 0 0 0 0 0.00 ENE 0 0 0 0 0 0 0 0.00 E 0 0 0 0 0 0 0 0.00 ESE 0 0 0 0 0 0 0 0.00 SE 0 0 0 0 0 0 0 0.00 SSE 0 0 0 0 0 0 0 0.00 S 0 0 0 0 0 0 0 0.00 SSW 0 0 0 0 0 0 0 0.00 SW 0 0 0 0 0 0 0 0,00 WSW 0 0 0 0 0 0 0 0.00 W 0 0 0 0 0 0 0 0.00 WNW 0 0 0 0 0 0 0 0.00 NW 0 0 0 0 0 0 0 0.00 NNW 0 0 0 0 0 0 0 0.00 Total 00 0 0 0 0 0 0O Hours of Calm : 0 Hours of Varying Wind Direction 00 Hours of Missing Data 0 Hours of Missing Data for All 5 Hours of No Stability Class 0 Total hours of observation : 5 TABLE 8 SECOND QUARTER 2002 PAGE 50F8
JOINT WIND FREQUENCY DISTRIBUTION BY STABILITY CLASS SITE: V. C. SUMMER Nuclear Station UNIT 1 Report Date : 03-02-27 Data Period : 2- 6-17 11:00 to 2- 6-17 15:00 Stability Class: F delta T/ delta z 61->10 m Delta T With Substitution Wind Sensor Height : 10 meter +++ Batch Release Times Only +++
Hours at Each Wind Direction and Speed Wind Wind Speed (miles/hour)
Direction Mean 0.75- <4 4- <8 8- <13 13- <19 19- 24 >24 Total' Speed N 0 0 0 0 0 0 0 0.00 NNE 0 0 0 0 0 0 0 0.00 NE 0 0 0 0 0 0 0 0.00 ENE 0 0 0 0 0 0 0 0.00 E 0 0 0 0 0 0 0 0.00 ESE 0 0 0 0 0 0 0 0.00 SE 0 0 0 0 0 0 0 0.00 SSE 0 0 0 0 0 0 0 0.00 S 0 0 0 0 0 0 0 0.00 SSW 0 0 0 0 0 0 0 0.00 SW 0 0 0 0 0 0 0 0.00 WSW 0 0 0 0 0 0 0 0.00 W 0 0 0 0 0 0 0 0.00 WNW 0 0 0 0 0 0 0 0.00 NW 0 0 0 0 0 0 0 0.00 NNW 0 0 0 0 0 0 0 0.00 Total 0 0 0 0 0 0 0 Hours of Calm 0.
Hours of Varying Wind Direction.: 0F Hours of Missing Data 0 Hours of Missing Data for All 5 Hours of No Stability Class 0 Total hours of observation 5 TABLE 8 SECOND QUARTER 2002 PAGE 60F8
JOINT WIND FREQUENCY DISTRIBUTION BY STABILITY CLASS SITE: V. C. SUMMER Nuclear Station UNIT 1 Report Date : 03-02-27 Data Period : 2- 6-17 11:00 to 2- 6-17 15:00 Stability Class: G. .delta T/ delta z 61->10 m Wind Sensor Height : 10 meter Delta T With Substitution
+++ Batch Release Times Only +++
Hours at Each Wind Direction and Speed Wind Wind Speed (miles/hour)
Direction--
0.75- <4 4- <8 8- <13 13- <19 19- 24 Totl'Mean
>24 Total' Speed
_ _ _ _ _ _ _ _ _ _ _ _0_ _ _ _ _ _ _ _ _ _0_0_0_0 N__ __ _______ _______ ________ _______
N 0 0 0 0 NNE 0 0 0 0.00 0 0 0 0 0 NE 0 0 0 0.00 0 0 0 0 0 ENE 0 0 0.00 0 0 0 0 0 E 0 0 0 0.00 0 0 0 0 0 0.00 ESE 0 0 0 0 SE 0 0 0 0.00 0 0 0 0 0 0 SSE 0 0 0 0.00 0 0 0 0 0 0.00 S 0 0 0 0 SSW 0 0 0 0.00 0 0 0 0 0 SW 0 0 0 0 0.00 0 0 WSW 0 0 0 0 0 0.00 0 0 0 W 0 0 0 0 0.00 0 0 WNW 0 0 0 0 0 0.00 0 0 0 0 0 0.00 NW 0 0 0 0 0 0 0 0.00 NNW 0 0 0 0 0 0 0 0. 00
__________________0_____0_____0_____0__
Total 0 0 0 0f 0 0o 0 Hours of Calm :
Hours of Varying Wind Direction :
Hours of Missing Data :
Hours of Missing Data for All :5 Hours of No Stability Class :
Total hours of observation :5 TABLE 8 SECOND QUARTER 2002 PAGE 7OF 8
JOINT WIND FREQUENCY DISTRIBUTION BY STABILITY CLASS SITE: V. C. SUMMER Nuclear Station UNIT 1 Report Date : 03-02-27 Data Period : 2- 6-17 11:00 to 2- 6-17 15:00 Stability Class:ALL delta T/ delta z 61->10 m Delta T With Substitution Wind Sensor Height : 10 meter +++ Batch Release Times Only +++
Hours at Each Wind Direction and Speed Wind Wind Speed (miles/hour)
Direction 0.75- <4 4- <8 mean 8- <13 13- <19 19- 24 >24 Total' Speed N_ _ _ _ _ _ 0_ _ _ 0_ _ _ _ _
00 _ _ _ __ _ _
0 0 N 0 0 0 0 0 0 0 0.00 NNE 0 0 0 0 0 0 0 0.00 NE 0 0 0 0 0 0 0 0.00 ENE 0 0 0 0 0 0 0 0.00 E 0 0 0 0 0 0 0 0.00 ESE 0 0 0 0 0 0 0 0.00 SE 0 0 0 0 0 0 0 0.00 SSE 0 0 0 0 0 0 0 0.00 S 0 0 0 0 0 0 0 0.00 SSW 0 0 0 0 0 0 0 0.00 WSW 0 0 0 0.00 0 0 0 0 W 0 0 0 0.00 0 0 0 0 WNW 0 0 0 0.00 0 0 0 0 0 NW 0 0 0.00 0 0 0 0 0 0.00 NNW 0 0 0 0 0 0 0 0. 00 Total_________0_ _ _ _ _ _ _ _- _ _0__
-0_ _
Total 0 0 0o 0 0 0 0 Hours of Calm : 0 Hours of Varying Wind Direction : 0 Hours of Missing Data for All 5 Hours of No Stability Class 0 Total hours of observation : 5 TABLE 8 SECOND QUARTER 2002 PAGE 80F8
JOINT WIND FREQUENCY DISTRIBUTION BY STABILITY CLASS SITE: V. C. SUMMER Nuclear Station UNIT 1 Report Date : 03-02-27 Data Period : 2 9 08:00 to 2 9 10:00 Stability Class: A delta T/ delta z 61->10 m Delta T With Substitution Wind Sensor Height : 10 meter +++ Batch Release Times Only +÷ Hours at Each Wind Direction and Speed Wind Wind Speed (miles/hour)
Direction Me an 0.75- <4 4- <8 8- <13 13- <19 19- 24 >24 Total ' Speed N 0 0 0 0 0 0 0 0.00 NNE 0 0 0 0 0 .0 0 0. 00 NE 0 0 0 0 0 0 0 0. 00 ENE 0 0 0 0 0 0 0 0.00 E 0 0 0 0 O 0 O 0.00 ESE 0 0 0 0 0 0 0 0. 00 SE 0 0 0 0 0 0 0 0.00 SSE 0 0 0 0 0 0 0 .00 S 0 0 0 0 0 0- 0 0. 00 SSW 0 0 0 0 0 0 0 0. 00 SW 0 0 0 0 0 0 0 0. 00 WSW 0 1 0 0 0 0 1 5.70 W 0 1 0 0 0 0 1 6.19 WNW 0 0 0 0 0 0 0 0. 00 NW 0 0 0 0 0 0 0 0. 00 NNW 0 0 0 0 0 0 0 0. 00 Total 0 2 0 0 0 0 2 Hours of Calm : 0 Hours of Varying Wind Direction : 0 Hours of Missing Data : 0 Hours of Missing Data for All : 0 Hours of No Stability Class 0 Total hours of observation 3 TABLE 8 THIRD QUARTER 2002-PAGE 1OF 8
JOINT WIND FREQUENCY DISTRIBUTION BY STABILITY CLASS SITE: V. C. SUMMER Nuclear Station UNIT 1 Report Date : 03-02-27 Data Period : 2 9 08:00 to 2 9 10:00 Stability Class: B delta T/ delta z 61->10 m Delta T With Substitution Wind Sensor Height : 10 meter +++ Batch Release Times Only +++
Hours at Each Wind Direction and Speed Wind Wind Speed (miles/hour)
Direction Mean 0.75- <4 4- <8 8- <13 13- <19 19- 24 >24 Total' Speed N 0 0 0 0 0 0 0 0.00 NNE 0 0 0 0 0 0 0 0.00 NE 0 0 0 0 0 0 0 0.00 ENE 0 0 0 0 0 0 0 0.00 E 0 0 0 0 0 0 0 0.00 ESE 0 0 0 0 0 0 0 0.00 SE 0 0 0 0 0 0 0 0.00 SSE 0 0 0 0 0 0 0 0.00 S 0 0 0 0 0 0 0 0.00 SSW 0 0 0 0 0 0 0 0.00 SW 0 0 0 0 0 0 0 0.00 WSW 0 1 0 0 0 0 1 4.65 W 0 0 0 0 0 0 0 0.00 WNW 0 0 0 0 0 0 0 0.00 NW 0 0 0 0 0 0 0 0.00 NNW 0 0 0 0 0 0 0 0.00 Total 0 1 0 0 0 0 1 Hours of Calm 0 Hours of Varying Wind Direction 0 Hours of Missing Data 0 Hours of Missing Data for All 0 Hours of No Stability Class 0 Total hours of observation 3 TABLE 8 THIRD QUARTER 2002 PAGE 2 OF 8
JOINT WIND FREQUENCY DISTRIBUTION BY STABILITY CLASS SITE: V. C. SUMMER Nuclear Station UNIT 1 Report Date : 03-02-27 Data Period : 2 9 08:00 to 2 9 10:00 Stability Class: C delta T/ delta z 61->10 m Delta T With Substitution Wind Sensor Height : 10 meter +++ Batch Release Times Only +++
Hours at Each Wind Direction and Speed Wind Wind Speed (miles/hour)
Direction Mean 0.75- <4 4- <8 8- <13 13- <19 19- 24 >24 Total' Speed N 0 0 0 0 0 0 0 0.00 NNE 0 0 0 0 0 0 0 0.00 NE 0 0 0 0 0 0 0 0.00 ENE 0 0 0 0 0 0 0 0.00 E 0 0 0 0 0 0 0 0.00 ESE 0 0 0 0 0 0 0 0.00 SE 0 0 0 0 0 0 0 0.00 SSE 0 0 0 0 0 0 0 0.00 S 0 0 0 0 0 0 0 0.00 SSW 0 0 0 0 0 0 0 0.00 SW 0 0 0 0 0 0 0 0.00 WSW 0 0 0 0 0 0 0 0.00 W 0 0 0 0 0 0 0 0.00 WNW 0 0 0 0 0 0 0 0.00 NW 0 0 0 0 0 0 0 0.00 NNW 0 0 0 0 0 0 0 0.00 Total 0 0 0 0 0 0 0 Hours of Calm : 0 Hours of Varying Wind Direction : 0 Hours of Missing Data : 0 Hours of Missing Data for All : 0 Hours of No Stability Class : 0 Total hours of observation 3 TABLE 8 THIRD QUARTER 2002 PAGE 3 OF 8
JOINT WIND FREQUENCY DISTRIBUTION BY STABILITY CLASS SITE: V. C. SUMMER Nuclear Station UNIT 1 Report Date : 03-02-27 Data Period : 2 9 08:00 to 2 9 10:00 Stability Class: D delta T/ delta z 61->10 m Delta T With Substitution Wind Sensor Height : 10 meter +++ Batch Release Times Only +++
Hours at Each Wind Direction and Speed Wind Wind Speed (miles/hour)
Direction Mean 0.75- <4 4- <8 8- <13 13- <19 19- 24 >24 Total' Speed N 0 0 0 0 0 0 0 0.00 NNE 0 0 0 0 0 0 0 0.00 NE 0 0 0 0 0 0 0 0.00 ENE 0 0 0 0 0 0 0 0.00 E 0 0 0 0 0 0 0 0.00 ESE 0 0 0 0 0 0 0 0.00 SE 0 0 0 0 0 0 0 0.00 SSE 0 0 0 0 0 0 0 0.00 S 0 0 0 0 0 0 0 0.00 SSW 0 0 0 0 0 0 0 0.00 SW 0 0 0 0 0 0 0 0.00 WSW 0 0 0 0 0 0 0 0 00 W 0 0 0 0 0 0 0 0.00 WNW 0 0 0 0 0 0 0 0.00 NW 0 0 0 0 0 0 0 0.00 NNW 0 0 0 0 0 0 0 0.00 Total 0 0 0 0 0 0 0 Hours of Calm : 0 Hours of Varying Wind Direction : 0 Hours of Missing Data : 0 Hours of Missing Data for All : 0 Hours of No Stability Class : 0 Total hours of observation : 3 TABLE 8 THIRD QUARTER 2002 PAGE 4 OF 8
JOINT WIND FREQUENCY DISTRIBUTION BY STABILITY CLASS SITE: V. C. SUMMER Nuclear Station UNIT 1 Report Date : 03-02-27 Data Period : 2 9 08:00 to 2 9 10:00 Stability Class: E delta T/ delta z 61->10 m Delta T With Substitution Wind Sensor Height : 10 meter +++ Batch Release Times Only +++
Hours at Each Wind Direction and Speed Wind Wind Speed (miles/hour)
VIe d"I Direction 0.75- <4 4- <8 8- <13 13- <19 19- 24 >24 Total' Speed N__ _ _ _ _0__
_ _ _ _ _ _ _ _ _ 0_
_ _ _ _ _ _ _ _ _ 0_ _ _ _ 0_0_ 0 0.00 N 0 0 0 0 0 0 0 0 0 0 0 0 0 0.00 NNE 0 0 0 0 0 0 0 0.00 NE 0 0.00 ENE 0 0 0 0 0 0 0 0 0 0 0 0 0.00 E 0 0 0 0 0 0 0 0.00 ESE 0 0.00 0 0 0 0 0 0 SE 0 0 0 0 0 0 0 0.00 SSE 0 0 0 0 0 0 0 0.00 S 0 0 0 0 0 0 0 0.00 SSW 0 0 0 0 0 0 0 0.00 SW 0 0 0 0 0 0 0 0 0.00 WSW 0 0 0 0 0 0 0 0.00 W
0 0 0 0 0 0 0.00 WNW 0 0 0 0 0 0 0 0.00 NW 0 0 0 0 0 0 0 0.00 NNW 0
° ° 0 Total Hours of Calm 0 Hours of Varying Wind Direction : 0 Hours of Missing Data 0 Hours of Missing Data for All 0 Hours of No Stability Class 0 hours0 days <br />0 hours <br />0 weeks <br />0 months <br /> of observation : 3 Total TABLE 8 THIRD QUARTER 2002 PAGE 50F8
JOINT WIND FREQUENCY DISTRIBUTION BY STABILITY CLASS SITE: V. C. SUMMER Nuclear Station UNIT 1 Report Date : 03-02-27 Data Period : 2 9 08:00 to 2 9 10:00 Stability Class: F delta T/ delta z 61->10 m Delta T With Substitution Wind Sensor Height : 10 meter +++ Batch Release Times Only +++
Hours at Each Wind Direction and Speed Wind Wind Speed (miles/hour)
Direction Mean 0.75- <4 4- <8 8- <13 13- <19 19- 24 >24 Total' Speed N 0 0 0 0 0 0 0 0.00 NNE 0 0 0 0 0 0 0 0.00 NE 0 0 0 0 0 0 0 0.00 ENE 0 0 0 0 0 0 0 0.00 E 0 0 0 0 0 0 0 0.00 ESE 0 0 0 0 0 0 0 0.00 SE 0 0 0 0 0 0 0 0.00 SSE 0 0 0 0 0 0 0 0.00 S 0 0 0 0 0 0 0 0.00 SSW 0 0 0 0 0 0 0 0.00 SW 0 0 0 0 0 0 0 0.00 WSW 0 0 0 0 0 0 0 0.00 W 0 0 0 0 0 0 0 0.00 WNW 0 0 0 0 0 0 0 0.00 NW 0 0 0 0 0 0 0 0.00 NNW 0 0 0 0 0 0 0 0.00 Total 0 0 0 0 0 0 0 Hours of Calm : 0 Hours of Varying Wind Direction : 0 Hours of Missing Data : 0 Hours of Missing Data for All : 0 Hours of No Stability Class : 0 Total hours of observation : 3 TABLE 8 THIRD QUARTER 2002 PAGE 6 OF 8
JOINT WIND FREQUENCY DISTRIBUTION BY STABILITY CLASS SITE: V. C. SUMMER Nuclear Station UNIT 1 Report Date : 03-02-27 Data Period : 2 9 08:00 to 2 9 10:00 Stability Class: G delta T/ delta z 61->10 m Delta T With Substitution Wind Sensor Height : 10 meter +++ Batch Release Times Only +++
Hours at Each Wind Direction and Speed Wind Wind Speed (miles/hour)
Direction Mean 0.75- <4 4- <8 8- <13 13- <19 19- 24 >24 Total' Speed N 0 0 0 0 0 0 0 0.00 NNE 0 0 0 0 0 0 0 0.00 NE 0 0 0 0 0 0 0 0.00 ENE 0 0 0 0 0 0 0 0.00 E 0 0 0 0 0 0 0 0.00 ESE 0 0 0 0 0 0 0 0.00 SE 0 0 0 0 0 0 0 0.00 SSE 0 0 0 0 0 0 0 0.00 S 0 0 0 0 0 0 0 0.00 SSW 0 0 0 0 0 0 0 0.00 SW 0 0 0 0 0 0 0 0.00 WSW 0 0 0 0 0 0 0 0.00 W 0 0 0 0 0 0 0 0.00 WNW 0 0 0 0 0 0 0 0.00 NW 0 0 0 0 0 0 0 0.00 NNW 0 0 0 0 0 0 0 0.00 Total 0 0 0 0 0 0 0 Hours of Calm : 0 Hours of Varying Wind Direction : 0 Hours of Missing Data : 0 Hours of Missing Data for All 0 Hours of No Stability Class : 0 Total hours of observation : 3 TABLE 8 THIRD QUARTER 2002 PAGE 7 OF 8
JOINT WIND FREQUENCY DISTRIBUTION BY STABILITY CLASS SITE: V. C. SUMMER Nuclear Station UNIT 1 Report Date : 03-02-27 Data Period : 2 9 08:00 to 2 9 10:00 Stability Class:ALL delta T/ delta z 61->10 m Delta T With Substitution Wind Sensor Height : 10 meter +++ Batch Release Times Only +++
Hours at Each Wind Direction and Speed Wind Wind Speed (miles/hour)
Direction Mean 0.75- <4 4- <8 8- <13 13- <19 19- 24 >24 Total' Speed N 0 0 0 0 0 0 0 0.00 NNE 0 0 0 0 0 0 0 0.00 NE 0 0 0 0 0 0 0 0.00 ENE 0 0 0 0 0 0 0 0.00 E 0 0 0 0 0 0 0 0.00 ESE 0 0 0 0 0 0 0 0.00 SE 0 0 0 0 0 0 0 0.00 SSE 0 0 0 0 0 0 0 0.00 S 0 0 0 0 0 0 0 0.00 SSW 0 0 0 0 0 0 0 0.00 SW 0 0 0 0 0 0 0 0.00 WSW 0 2 0 0 0 0 2 5.17 W 0 1 0 0 0 0 1 6.19 WNW 0 0 0 0 0 0 0 0.00 NW 0 0 0 0 0 0 0 0.00 NNW 0 0 0 0 0 0 0 0.00 Total 0 3 0 0 0 0 3 Hours of Calm : 0 Hours of Varying Wind Direction : 0 Hours of Missing Data for All : 0 Hours of No Stability Class : 0 Total hours of observation : 3 TABLE 8 THIRD QUARTER 2002 PAGE 8 OF 8
JOINT WIND FREQUENCY DISTRIBUTION BY STABILITY CLASS SITE: V. C. SUMMER Nuclear Station UNIT 1 Report Date : 03-02-27 Data Period : 2 8 09:00 to 2 8 10:00 Stability Class: A delta T/ delta z 61->10 m Delta T With Substitution Wind Sensor Height : 10 meter +++ Batch Release Times Only +++
Hours at Each Wind Direction and Speed Wind Wind Speed (miles/hour)
Direction Mean 0.75- <4 4- <8 8- <13 13- <19 19- 24 >24 Total' Speed N 0 0 0 0 0 0 0 0.00 NNE 0 0 0 0 0 0 0 0.00 NE 0 1 0 0 0 0 1 4.75 ENE 0 0 0 0 0 0 0 0.00 E 0 0 0 0 0 0 0 0.00 ESE 0 0 0 0 0 0 0 0.00 SE 0 0 0 0 0 0 0 0.00 SSE 0 0 0 0 0 0 0 0.00 S 0 0 0 0 0 0 0 0.00 SSW 0 0 0 0 0 0 0 0.00 SW 0 0 0 0 0 0 0 0.00 WSW 0 0 0 0 0 0 0 0.00 W 0 0 0 0 0 0 0 0.00 WNW 0 0 0 0 0 0 0 0.00 NW 0 0 0 0 0 0 0 0.00 NNW 0 0 0 0 0 0 0 0.00 Total 0 1 0 0 0 0 1 Hours of Calm : 0 Hours of Varying Wind Direction : 0 Hours of Missing Data : 0 Hours of Missing Data for All : 0 Hours of No Stability Class 0 Total hours of observation : 2 TABLE 8 THIRD QUARTER 2002 PAGE 10F8
JOINT WIND FREQUENCY DISTRIBUTION BY STABILITY CLASS SITE: V. C. SUMMER Nuclear Station UNIT 1 Report Date : 03-02-27 Data Period : 2 8 09:00 to 2 8 10:00 Stability Class: B delta T/ delta z 61->10 m Delta T With Substitution Wind Sensor Height : 10 meter +++ Batch Release Times Only +++
Hours at Each Wind Direction and Speed Wind Wind Speed (miles/hour)
Direction Mean 0.75- <4 4- <8 8- <13 13- <19 19- 24 >24 Total' Speed N 0 0 0 0 0 0 0 0.00 NNE 0 0 0 0 0 0 0 0.00 NE 0 0 0 0 0 0 0 0.00 ENE 0 1 0 0 0 0 1 5.80 E 0 0 0 0 0 0 0 0.00 ESE 0 0 0 0 0 0 0 0.00 SE 0 0 0 0 0 0 0 0.00 SSE 0 0 0 0 0 0 0 0.00 S 0 0 0 0 0 0 0 0.00 SSW 0 0 0 0 0 0 0 0.00 SW 0 0 0 0 0 0 0 0.00 WSW 0 0 0 0 0 0 0 0.00 W 0 0 0 0 0 0 0 0.00 WNW 0 0 0 0 0 0 0 0.00 NW 0 0 0 0 0 0 0 0.00 NNW 0 0 0 0 0 0 0 0.00 Total 0 1 0 0 0 0 1 Hours of Calm : 0 Hours of Varying Wind Direction : 0 Hours of Missing Data : 0 Hours of Missing Data for All : 0 Hours of No Stability Class : 0 Total hours of observation : 2 TABLE 8 THIRD QUARTER 2002 PAGE 20F8
JOINT WIND FREQUENCY DISTRIBUTION BY STABILITY CLASS SITE: V. C. SUMMER Nuclear Station UNIT 1 Report Date : 03-02-27 Data Period : 2 8 09:00 to 2 8 10:00 Stability Class: C delta T/ delta z 61->10 m Delta T With Substitution Wind Sensor Height : 10 meter +++ Batch Release Times Only +++
Hours at Each Wind Direction and Speed Wind Wind Speed (miles/hour)
Direction Mean 0.75- <4 4- <8 8- <13 13- <19 19- 24 >24 Total' Speed N 0 0 0 0 0 0 0 0.00 NNE 0 0 0 0 0 0 0 0.00 NE 0 0 0 0 0 0 0 0.00 ENE 0 0 0 0 0 0 0 0.00 E 0 0 0 0 0 0 0 0.00 ESE 0 0 0 0 0 0 0 0.00 SE 0 0 0 0 0 0 0 0.00 SSE 0 0 0 0 0 0 0 0.00 S 0 0 0 0 0 0 0 0.00 SSW 0 0 0 0 0 0 0 0.00 SW 0 0 0 0 0 0 0 0.00 WSW 0 0 0 0 0 0 0 0.00 W 0 0 0 0 0 0 0 0.00 WNW 0 0 0 0 0 0 0 0.00 NW 0 0 0 0 0 0 0 0.00 NNW 0 0 0 0 0 0 0 0.00 Total 0 0 0 0 0 0 0 Hours of Calm 0 Hours of Varying Wind Direction > 0 Hours of Missing Data : 0 Hours of Missing Data for All : 0 Hours of No Stability Class : 0 Total hours of observation : 2 TABLE 8 THIRD QUARTER 2002 PAGE 3 OF 8
JOINT WIND FREQUENCY DISTRIBUTION BY STABILITY CLASS SITE: V. C. SUMMER Nuclear Station UNIT 1 Report Date : 03-02-27 Data Period : 2 8 09:00 to 2 8 10:00 Stability Class: D delta T/ delta z >10 m Delta T With Substitution Wind Sensor Height : 10 meter +++ Batch Release Times Only +++
Hours at Each Wind Direction and Speed Wind Wind Speed (miles/hour)
Direction Mean 0.75- <4 4- <8 8- <13 13- <19 19- 24 >24 Total' Speed N 0 0 0 0 0 0 0 0.00 NNE 0 0 0 0 0 0 0 0.00 NE 0 0 0 0 0 0 0 0.00 ENE 0 0 0 0 0 0 0 0.00 E 0 0 0 0 0 0 0 0.00 ESE 0 0 0 0 0 0 0 0.00 SE 0 0 0 0 0 0 0 0.00 SSE 0 0 0 0 0 0 0 0.00 S 0 0 0 0 0 0 0 0.00 SSW 0 0 0 0 0 0 0 0.00 SW 0 0 0 0 0 0 0 0.00 WSW 0 0 0 0 0 0 0 0.00 W 0 0 0 0 0 0 0 0.00 WNW 0 0 0 0 0 0 0 0.00 NW 0 0 0 0 0 0 0 0.00 NNW 0 0 0 0 0 0 0 0.00 Total 0 0 0 0 0 0 0 Hours of Calm % 0 Hours of Varying Wind Direction : 0 Hours of Missing Data : 0 Hours of Missing Data for All : 0 Hours of No Stability Class : 0 Total hours of observation : 2 TABLE 8 THIRD QUARTER 2002 PAGE 4 OF 8
JOINT WIND FREQUENCY DISTRIBUTION BY STABILITY CLASS SITE: V. C. SUMMER Nuclear Station UNIT 1 Report Date : 03-02-27 Data Period : 2 8, 09:00 to 2 8 10:00 Stability Class: E delta T/ delta z 61->10 m Delta T With Substitution Wind Sensor Height : 10 meter +++ Batch Release Times Only +++
Hours at Each Wind Direction and Speed Wind Wind Speed (miles/hour)
Direction Mean I 0.75- <4 4- <8 8- <13 13- <19 19- 24 >24 Total. speea N 0 0 0 0 0 o o. oo 0 0 0 o o. oo NNE 0 0 0 NE 0 0 0 0 0 o o oo ENE 0 0 0 0 0 0 o o oo0 E 0 0 0 0 0 0 o o. oo ESE 0 0 0 0 0 0 o o. oo SE 0 0 0 0 0 0 o o. oo SSE 0 0 0 b 0 0 o o. oo S 0 0 0 0 0 0 o o. oo SSW 0 0 0 0 0 0 o o. oo SW 0 0 0 0 0 0 o o. oo WSW 0 0 0 0 0 0 o o. oo W 0 0 0 0 0 0 o o. oo WNW 0 0 0 0 0 0 o o. oo NW 0 0 0 0 0 o o. oo NNW 0 0 0 0 0 o o. oo Total 0 0 0 0 0 0 0 Hours of Calm
- I O Hours of Varying Wind Direction Hours of Missing Data :
Hours of Missing Data for All :
Hours of No Stability Class :
Total hours of observation :2 TABLE 8 THIRD QUARTER 2002 PAGE 5OF 8
JOINT WIND FREQUENCY DISTRIBUTION BY STABILITY CLASS SITE: V. C. SUMMER Nuclear Station UNIT 1 Report Date : 03-02-27 Data Period : 2 8 09:00 to 2 8 10:00 Stability Class: F delta T/ delta z 61->10 m Delta T With Substitution Wind Sensor Height : 10 meter +++ Batch Release Times Only +++
Hours at Each Wind Direction and Speed Wind Wind Speed (miles/hour)
Direction Meark. -3 0.75- <4 4- <8 8- <13 13- <19 19- 24 >Z4 rotal Speed N 0 0 0 0 0 0 0 0.00 0 0 0 0 0 0 0 0.00 NNE NE 0 0 0 0 0 0 0 0.00 0 0 0 0 0 0 0 0.00 ENE 0 0 0 0 0 0 0 0.00 E
0 0 0 0 0 0 0 0.00 ESE 0 0 0 0 0 0 0 0.00 SE 0 0 0 0 0 0 0 0.00 SSE S 0 0 0 0 0 0 0 0.00 SSW 0 0 0 0 0 0 0 0.00 SW 0 0 0 0 0 0 0 0.00 WSW 0 0 0 0 0 0 0 0.00 W 0 0 0 0 0 0 0 0.00 WNW 0 0 0 0 0 0 0 0.00 0 0 0 0 0 0 0 0.00 NW 0 0 0 0 0 0 0 0.00 NNW 0 0 0 0 0 0 0 Total Hours of Calm : 0 Hours of Varying Wind Direction : 0 Hours of Missing Data : 0 Hours of Missing Data for All : 0 Hours of No Stability Class : 0 Total hours of observation : 2 TABLE 8 THIRD QUARTER 2002 PAGE 6 OF 8
JOINT WIND FREQUENCY DISTRIBUTION BY STABILITY CLASS SITE: V. C. SUMMER Nuclear Station UNIT 1 Report Date : 03-02-27 Data Period : 2 8 09:00 to 2 8 10:00 Stability Class: G delta T/ delta z 61->10 m Delta T With Substitution Wind Sensor Height : 10 meter +++ Batch Release Times Only +++
Hours at Each Wind Direction and Speed Wind Wind Speed (miles/hour)
Direction Mean 0.75- <4 4- <8 8- <13 13- <19 19- 24 >24 Total' Speed N 0 0 0 0 0 0 0 0.00 NNE 0 0 0 0 0 0 0 0.00 NE 0 0 0 0 0 0 0 0.00 ENE 0 0 0 0 0 0 0 0.00 E 0 0 0 0 0 0 0 0.00 ESE 0 0 0 0 0 0 0 0.00 SE 0 0 0 0 0 0 0 0.00 SSE 0 0 0 0 0 0 0 0.00 S 0 0 0 0 0 0 0 0.00 SSW 0 0 0 0 0 0 0 0.00 SW 0 0 0 0 0 0 0 0.00 WSW 0 0 0 0 0 0 0 0.00 W 0 0 0 0 0 0 0 0.00 WNW 0 0 0 0 0 0 0 0.00 NW 0 0 0 0 0 0 0 0.00 NNW 0 0 0 0 0 0 0 0.00 Total 0 0 0 0 0 0 0 Hours of Calm : 0 Hours of Varying Wind Direction : 0 Hours of Missing Data : 0 Hours of Missing Data for All 0 Hours of No Stability Class : 0 Total hours of observation : 2 TABLE 8 THIRD QUARTER 2002 PAGE 7 OF 8
JOINT WIND FREQUENCY DISTRIBUTION BY STABILITY CLASS SITE: V. C. SUMMER Nuclear Station UNIT 1 Report Date : 03-02-27 Data Period : 2 8 09:00 to 2 8 10:00 Stability Class:ALL delta T/ delta z 61->10 m Delta T With Substitution Wind Sensor Height : 10 meter +++ Batch Release Times Only +++
Hours at Each Wind Direction and Speed Wind Wind Speed (miles/hour)
Direction Mean I 0.75- <4 4- <8 8- <13 13- <19 19- 24 >24 Total' Speed N 0 0 0- 0 0 0. 00 0o 0 0 0 0 0 .00 NNE 0 NE 1 0 0 1 4.75 0o D 0o 0 0 1 5. 80 ENE 1 0 0 0 0 0. 00 E 0 0 0 0 0 0 0. 00 ESE 0 0 0o 0o 0 0 0 0. 00 SE 0 0 0 0 0 0 0 0. 00 SSE 0 0 0 0 0 0. 00 S 0 0 0
0 0o 0 0 0 0. 00 SSW 0 0o 0 0 0 0 0 0. 00 SW 0 0 0 0 0 0 0 0.00 WSW 0 0 0 0 0 0 .00 W 0 0o 0 0 0 0.00 WNW 0 0 0 0 0 0. 00 NW 0 NNW 0 0 0 0 0 .00 Total___________________0_______2_______0_______0_______0_______0_______2___
Total 0 2 0 0 0 0 2 Hours of Calm :
Hours of Varying Wind Direction :
Hours of Missing Data for All :
Hours of No Stability Class :
Total hours of observation :2 TABLE 8 THIRD QUARTER 2002 PAGE 8 OF 8
i JOINT WIND FREQUENCY DISTRIBUTION BY STABILITY CLASS SITE: V. C. SUMMER Nuclear Station UNIT 1 Report Date : 03-02-27 Data Period : 2- B-29 10:00 to 2- 8-29 14:00 Stability Class: A delta T/ delta z 61->10 m Delta T With Substitution Wind Sensor Height : 10 meter +++ Batch Release Times Only +++
Hours at Each Wind Direction and Speed Wind Wind Speed (miles/hour)
Direction T 8ea-2 0.75- <4 4- <8 8- <13 13- <19 19- 24 >24 Total' Speed N 0 0 0 0 0 0 0 0.00 NNE 0 0 0 0 0 0 0 0.00 NE 0 0 0 0 0 0 0 0.00 ENE 0 0 0 0 0 0 0 0.00 E 0 0 0 0 0 0 0 0.00 ESE 0 0 0 0 0 0 0 0.00 I SE 0 0 0 0 0 0 0 0.00 SSE 0 0 0 0 0 0 0 0.00 S 0 0 0 0 0 0 0 0.00 SSW 0 0 0 0 0 0 0 0.00 SW 0 0 0 0 0 0 0 0.00 WSW 0 0 0 0 0 0 0 0.00 W 0 0 0 0 0 0 0 0.00 WNW 0 0 0 0 0 0 0 0.00 NW 0 0 0 0 0 0 0 0.00 NNW 0 0 0 0 0 0 0 0.00 Total 0 0 0 0 0 0 0 Hours of Calm 0 Hours of Varying Wind Direction 0 Hours of Missing Data 0 Hours of Missing Data for All 0 Hours of No Stability Class 0 Total hours of observation 5 TABLE 8 THIRD QUARTER 2002 PAGE 10F8
JOINT WIND FREQUENCY DISTRIBUTION BY STABILITY CLASS SITE: V. C. SUMMER Nuclear Station UNIT 1 Report Date : 03-02-27 Data Period : 2- 8-29 10:00 to 2- 8-29 14:00 Stability Class: B delta T/ delta z 61->10 m Delta T With Substitution Wind Sensor Height : 10 meter +++ Batch Release Times Only +++
Hours at Each Wind Direction and Speed Wind Wind Speed (miles/hour)
Direction Mean 0.75- <4 4- <8 8- <13 13- <19 19- 24 >24 Total' Speed N 0 0 0 0 0 0 0 0.00 NNE 0 0 0 0 0 0 0 0.00 NE 0 0 0 0 0 0 0 0.00 ENE 0 0 0 0 0 0 0 0.00 E 0 0 0 0 0 0 0 0.00 ESE 0 0 0 0 0 0 0 0.00 SE 0 0 0 0 0 0 0 0.00 SSE 0 0 0 0 0 0 0 0.00 S 0 0 0 0 0 0 0 0.00 SSW 0 0 0 0 0 0 0 0.00 SW 0 0 0 0 0 0 0 0.00 WSW 0 0 0 0 0 0 0 0.00 W 0 0 0 0 0 0 0 0.00 WNW 0 0 0 0 0 0 0 0.00 NW 0 0 0 0 0 0 0 0.00 NNW 0 0 0 0 0 0 0 0.00 Total 0 0 0 0 0 0 0 Hours of Calm : 0 Hours of Varying Wind Direction : 0 Hours of Missing Data : 0 Hours of Missing Data for All : 0 Hours of No Stability Class : 0 Total hours of observation 5 TABLE 8 THIRD QUARTER 2002 PAGE 20F8
JOINT WIND FREQUENCY DISTRIBUTION BY STABILITY CLASS SITE: V. C. SUMMER Nuclear Station UNIT 1 Report Date : 03-02-27 Data Period : 2- 8-29 10:00 to 2- 8-29 14:00 Stability Class: C delta T/ delta z 61->10 m Delta T With Substitution Wind Sensor Height : 10 meter +++ Batch Release Times Only +++
Hours at Each Wind Direction and Speed Wind Wind Speed (miles/hour)
Direction Mean 0.75- <4 4- <8 8- <13 13- <19 19- 24 >24 Total' Speed N 0 0 0 0 0 0 0 0.00 NNE 0 0 0 0 0 0 0 0.00 NE 0 0 0 0 0 0 0 0.00 ENE 0 1 1 0 0 0 2 7.76 E 0 0 0 0 0 0 0 0.00 ESE 0 0 0 0 0 0 0 0.00 SE 0 0 0 0 0 0 0 0.00 SSE 0 0 0 0 0 0 0 0.00 S 0 0 0 0 0 0 0 0.00 SSW 0 0 0 0 0 0 0 0.00 SW 0 0 0 0 0 0 0 0.00 WSW 0 0 0 0 0 0 0 0.00 W 0 0 0 0 0 0 0 0.00 WNW 0 0 0 0 0 0 0 0.00 NW 0 0 0 0 0 0 0 0.00 NNW 0 0 0 0 0 0 0 0.00 Total 0 1 1 0 0 0 2 Hours of Calm : 0 Hours of Varying Wind Direction : 0 Hours of Missing Data : 0 Hours of Missing Data for All : 0 Hours of No Stability Class 0 Total hours of observation : 5 TABLE 8 THIRD QUARTER 2002 PAGE 3 OF 8
JOINT WIND FREQUENCY DISTRIBUTION BY STABILITY CLASS SITE: V. C. SUMMER Nuclear Station UNIT 1 Report Date : 03-02-27 Data Period : 2- 8-29 10:00 to 2- 8-29 14:00 Stability Class: D delta T/ delta z 61->10 m Delta T With Substitution Wind Sensor Height : 10 meter +++ Batch Release Times Only +++
Hours at Each Wind Direction and Speed Wind Wind Speed (miles/hour)
Direction Mean 0.75- <4 4- <8 8- <13 13- <19 19- 24 >24 Total' Speed N 0 0 0 0 0 0 0 0.00 NNE 0 0 0 0 0 0 0 0.00 NE 0 0 0 0 0 0 0 0.00 ENE 0 2 1 0 0 0 3 7.63 E 0 0 0 0 0 0 0 0.00 ESE 0 0 0 0 0 0 0 0.00 SE 0 0 0 0 0 0 0 0.00 SSE 0 0 0 0 0 0 0 0.00 S 0 0 0 0 0 0 0 0.00 SSW 0 0 0 0 0 0 0 0.00 SW 0 0 0 0 0 0 0 0.00 WSW 0 0 0 0 0 0 0 0.00 W 0 0 0 0 0 0 0 0.00 WNW 0 0 0 0 0 0 0 0.00 NW 0 0 0 0 0 0 0 0.00 NNW 0 0 0 0 0 0 0 0.00 Total 0 2 1 0 0 0 3 Hours of Calm : 0 Hours of Varying Wind Direction : 0 Hours of Missing Data : 0 Hours of Missing Data for All : 0 Hours of No Stability Class 0 Total hours of observation : 5 TABLE 8 THIRD QUARTER 2002 PAGE 4 OF 8
JOINT WIND FREQUENCY DISTRIBUTION BY STABILITY CLASS SITE: V. C. SUMMER Nuclear Station UNIT 1 Report Date : 03-02-27 Data Period : 2- 8-29 10:00 to 2- 8-29 14:00 Stability Class: E delta T/ delta z 61->10 m Delta T With Substitution Wind Sensor Height : 10 meter +++ Batch Release Times Only +++
Hours at Each Wind Direction and Speed Wind Wind Speed (miles/hour)
Direction Mean 0.75- <4 4- <8 8- <13 13- <19 19- 24 >24 Total' Speed N 0 0 0 0 0 0 0 0.00 NNE 0 0 0 0 0 0 0 0.00 NE 0 0 0 0 0 0 0 0.00 ENE 0 0 0 0 0 0 0 0.00 E 0 0 0 0 0 0 0 0.00 ESE 0 0 0 0 0 0 0 0.00 SE 0 0 0 0 0 0 0 0.00 SSE 0 0 0 0 0 0 0 0.00 S 0 0 0 0 0 0 0 0.00 SSW 0 0 0 0 0 0 0 0.00 SW 0 0 0 0 0 0 0 0.00 WSW 0 0 0 0 0 0 0 0.00 W 0 0 0 0 0 0 0 0.00 WNW 0 0 0 0 0 0 0 0.00 NW 0 0 0 0 0 0 0 0.00 NNW 0 0 0 0 0 0 0 0.00 Total 0 0 0 0 0 0 0 Hours of Calm 0 Hours of Varying Wind Direction 0 Hours of Missing Data : 0 Hours of Missing Data for All : 0 Hours of No Stability Class : 0 Total hours of observation : 5 TABLE 8 THIRD QUARTER 2002 PAGE SOF 8
JOINT WIND FREQUENCY DISTRIBUTION BY STABILITY CLASS SITE: V. C. SUMMER Nuclear Station UNIT 1 Report Date : 03-02-27 Data Period : 2- 8-29 10:00 to 2- 8-29 14:00 Stability Class: F delta T/ delta z 61->10 m Delta T With Substitution Wind Sensor Height : 10 meter +++ Batch Release Times Only +++
Hours at Each Wind Direction and Speed Wind Wind Speed (miles/hour) Ma "
Direction >24 Total' Speed 0.75- <4 4- <8 8- <13 13- <19 19- 24
_ _ _ _0__ _ _ _ _0__ _ _ _ _0__ _ _ _ _0__ _ _ _0__ _ _ _ _0_
N__ _ 0 0 0.00 N 0 0 0 0 0 0 0 0 0 0 0.00 NNE 0 0 0 0.00 0 0 0 0 0 0 NE 0 0.00 0 0 ° ° ° ENE 0 0.00 0 0 0 0 0 0 E 0 0 0.00 ESE 0 0 0 0 0 0 0 0 0 0 0.00 SE 0 0 0 0.00 0 0 0 0 0 0 SSE 0 0 0.00 0 0 0 0 0 S 0 0.00 0 0 0 0 0 0 SSW 0 0.00 0 0 0 0 0 0 SW 0 0.00 0 0 0 0 0 0 WSW 0 0.00 0 0 0 0 0 0 W 0 0.00 0 0 0 0 0 0 WNW 0 0 0.00 NW 0 0 0 0 0 0 0 0 0 0 0.00 NNW 0 0 Total__________________0______0_______0______0______0_______0__
° ° 0 Total ° 0
Hours of Calm 0 Hours of Varying Wind Direction 0 Hours of Missing Data : 0 Hours of Missing Data for All : 0 Hours of No Stability Class Total hours of observation 5 TABLE 8 THIRD QUARTER 2002 PAGE 6 OF 8
JOINT WIND FREQUENCY DISTRIBUTION BY STABILITY CLASS SITE: V. C. SUMMER Nuclear Station UNIT 1 Report Date : 03-02-27 Data Period : 2- 8-29 10:00 to 2- 8-29 14:00 Stability Class: G delta T/ delta z 61->10 m Delta T With Substitution Wind Sensor Height : 10 meter +++ Batch Release Times Only +.+
Hours at Each Wind Direction and Speed Wind Wind Speed (miles/hour)
Direction Mean 0.75- <4 4- <8 8- <13 13- <19 19- 24 >24 Total' Speed N 0 0 0 0 0 0 0 0.00 NNE 0 0 0 0 0 0 0 0.00 NE 0 0 0 0 0 0 0 0.00 ENE 0 0 0 0 0 0 0 0.00 E 0 0 0 0 0 0 0 0.00 ESE 0 0 0 0 0 0 0 0.00 SE 0 0 0 0 0 0 0 0.00 SSE 0 0 0 0 0 0 0 0.00 S 0 0 0 0 0 0 0 0.00 SSW 0 0 0 0 0 0 0 0.00 SW 0 0 0 0 0 0 0 0.00 WSW 0 0 0 0 0 0 0 0.00 W 0 0 0 0 0 0 0 0.00 WNW 0 0 0 0 0 0 0 0.00 NW 0 0 0 0 0 0 0 0.00 NNW 0 0 0 0 0 0 0 0.00 Total 0 0 0 0 0 0 0 Hours of Calm : 0 Hours of Varying Wind Direction : 0 Hours of Missing Data : 0 Hours of Missing Data for All : 0 Hours of No Stability Class : 0 Total hours of observation : 5 TABLE 8 THIRD QUARTER 2002 PAGE 7 OF 8
JOINT WIND FREQUENCY DISTRIBUTION BY STABILITY CLASS SITE: V. C. SUMMER Nuclear Station UNIT 1 Report Date : 03-02-27 Data Period : 2- 8-29 10:00 to 2- 8-29 14:00 Stability Class:ALL delta T/ delta z 61->10 m Delta T With Substitution Wind Sensor Height : 10 meter +++ Batch Release Times Only +++
Hours at Each Wind Direction and Speed Wind Wind Speed (miles/hour)
Direction mean 0.75- <4 4- <8 8- <13 13- <19 19- 24 >24 Total' Speed N 0 0 0 0 0 0 0 0.00 0 0 0 0 0 0 0 0.00 NNE 0 0 0 0 0 0 0 0.00 NE 0 ENE 0 3 2 0 0 5 7.69 0 0 0 0 0 0 0 0.00 E 0 0 0 0 0 0 0 0.00 ESE 0 0 0.00 SE 0 0 0 0 0 0 0 0 0 0 0 0 0.00 SSE 0 S 0 0 0 0 0 0 0.00 e0 0 0 0 0 0 0 0.00 SSW 0 0 0 0 0 0 0 0.00 SW 0 0 0 0 0 0 0 0.00 WSW 0 0 0 0 0 0 0 0.00 W
0 0 0 0 0 0 0 0.00 WNW 0 0 0 0 0 0 0 0.00 NW 0 0 0 0 0 0 0 0.00 NNW Tota__________________0_______3______2______0_______0_.
Total 0 3 2 0 0 0 5 Hours of Calm 0 Hours of Varying Wind Direction 0 Hours of Missing Data for All 0 Hours of No Stability Class 0 Total hours of observation 5 TABLE 8 THIRD QUARTER 2002 PAGE 8 OF 8
JOINT WIND FREQUENCY DISTRIBUTION BY STABILITY CLASS SITE: V. C. SUMMER Nuclear Station UNIT 1 Report Date : 03-02-27 Data Period : 2 5 08:00 to 2 5 10:00 Stability Class: A delta T/ delta z 61->10 m Delta T With Substitution Wind Sensor Height : 10 meter +++ Batch Release Times Only +++
Hours at Each Wind Direction and Speed Wind Wind Speed (miles/hour)
Direction Mean 0.75- <4 4- <8 8- <13 13- <19 19- 24 >24 Total' Speed N 0 0 0 0 0 0 0. 00 0 0 0 0 0. 00 NNE 0 0 0 0
o0 0 0 0 0. 00 NE 0 0 0 0 0 0 0 0. 00 ENE 0 0 0 0 0 0 0 0. 00 E 0 0 0 0 0 0 0 0. 00 ESE 0 0 0 0 0 0 0 0. 00 SE 0 0 0 0 0 0 0 0.00 SSE 0 0 0 0 0 0 0. 00 S 0 0 0 0 0 0 0 0 0. 00 SSW 0 0 0 0 0 0 0. 00 SW 0 0 0 0 0 0 0 0. 00 WSW 0 0 0o oo0 0 0 0 0. 00 W 0 0 0 0 0 0 0 0. 00 WNW 0 0 0 0 NW 0 0 0 0 0 0. 00 0 0 0 0 0. 00 NNW 0 0 Total___________________0_______0_______0_______0_______0_______0_______0___
Total 0 0 0 0 ° ° ° Hours of Calm :
Hours of Varying Wind Direction :
Hours of Missing Data :
Hours of Missing Data for All :
Hours of No Stability Class :
Total hours of observation :3 TABLE 8 THIRD QUARTER 2002 PAGE 1OF 8
JOINT WIND FREQUENCY DISTRIBUTION BY STABILITY CLASS SITE: V. C. SUMMER Nuclear Station UNIT 1 Report Date : 03-02-27 Data Period : 2 5 08:00 to 2 5 10:00 Stability Class: B delta T/ delta z 61->10 m Delta T With Substitution Wind Sensor Height : 10 meter .++Batch Release Times Only +++
Hours at Each Wind Direction and Speed Wind Wind Speed (miles/hour)
Direction Mean 0.75- <4 4- <8 8- <13 13- <19 19- 24 >24 Total' Speed N 0 0 0 0 0 0 0 0.00 NNE 0 0 0 0 0 0 0 0.00 NE 0 0 0 0 0 0 0 0.00 ENE 0 0 0 0 0 0 0 0.00 E 0 0 0 0 0 0 0 0.00 ESE 0 0 0 0 0 0 0 0.00 SE 0 0 0 0 0 0 0 0.00 SSE 0 0 0 0 0 0 0 0.00 S 0 0 0 0 0 0 0 0.00 SSW 0 0 0 0 0 0 0 0.00 SW 0 0 0 0 0 0 0 0.00 WSW 0 0 0 0 0 0 0 0.00 W 0 0 0 0 0 0 0 0.00 WNW 0 0 0 0 0 0 0 0.00 NW 0 0 0 0 0 0 0 0.00 NNW 0 0 0 0 0 0 0 0. 00 Total 0 0 0 0 0 0 0 Hours of Calm : 0 Hours of Varying Wind Direction 0 Hours of Missing Data : 0 Hours of Missing Data for All : 0 Hours of No Stability Class : 0 Total hours of observation : 3 TABLE 8 THIRD QUARTER 2002 PAGE 2 OF 8
JOINT WIND FREQUENCY DISTRIBUTION BY STABILITY CLASS SITE: V. C. SUMMER Nuclear Station UNIT 1 Report Date : 03-02-27 Data Period : 2 5 08:00 to 2 5 10:00 Stability Class: C delta T/ delta z 61->10 m Delta T With Substitution Wind Sensor Height : 10 meter +++ Batch Release Times Only +++
Hours at Each Wind Direction and Speed Wind Wind Speed (miles/hour)
Direction Meark-3 0.75- <4 4- <8 8- <13 13- <19 19- 24 >24 Tortal, Speed N 0 0 0 0 0 0 0 0.00 NNE 0 0 0 0 0 0 0 0.00 NE 0 0 0 0 0 0 0 0.00 ENE 1 0 1 0 0 0 2 5.94 E 0 0 0 0 0 0 0 0.00 ESE 0 0 0 0 0 0 0 0.00 SE 0 0 0 0 0 0 0 0.00 0 0 0 0 0 0 0 0.00 SSE 0 0 0 0 0 0 0 0.00 S
0 0 0 0 0 0 0 0.00 SSW 0 0 0 0 0 0 0 0.00 SW 0 0 0 0 0 0 0 0.00 WSW W 0 0 .0 0 0 0 0 0.00 0 0 .0 0 0 0 0 0.00 WNW 0 0 0 0 0 0 0 0.00 NW 0 0 0 0 0 0 0 0.00 NNW Total 1 0 1 0 0 0 2 Hours of Calm : 0 Hours of Varying Wind Direction 0 Hours of Missing Data 0 Hours of Missing Data for All : 0 Hours of No Stability Class : 0 Total hours of observation : 3 TABLE 8 THIRD QUARTER 2002 PAGE 3OF 8
JOINT WIND FREQUENCY DISTRIBUTION BY STABILITY CLASS SITE: V. C. SUMMER Nuclear Station UNIT 1 Report Date : 03-02-27 Data Period : 2 5 08:00 to 2 5 10:00 Stability Class: D delta T/ delta z 61->10 m Delta T With Substitution Wind Sensor Height : 10 meter +++ Batch Release Times Only +++
Hours at Each Wind Direction and Speed Wind Wind Speed (miles/hour)
Direction Mean 0.75- <4 4- <8 8- <13 13- <19 19- 24 >24 Total' Speed N 0 0 0 0 0 0 0 0.00 NNE 0 0 0 0 0 0 0 0.00 NE 0 0 0 0 0 0 0 0.00 ENE 1 0 0 0 0 0 1 3.12 E 0 0 0 0 0 0 0 0.00 ESE 0 0 0 0 0 0 0 0.00 SE 0 0 0 0 0 0 0 0.00 SSE 0 0 0 0 0 0 0 0.00 S 0 0 0 0 0 0 0 0.00 SSW 0 0 0 0 0 0 0 0.00 SW 0 0 0 0 0 0 0 0.00 WSW 0 0 0 0 0 0 0 0.00 W 0 0 0 0 0 0 0 0.00 WNW 0 0 0 0 0 0 0 0.00 NW 0 0 0 0 0 0 0 0.00 NNW 0 0 0 0 0 0 0 0.00 Total 1 0 0 0 0 0 1 Hours of Calm : 0 Hours of Varying Wind Direction : 0 Hours of Missing Data : 0 Hours of Missing Data for All : 0 Hours of No Stability Class : 0 Total hours of observation : 3 TABLE 8 THIRD QUARTER 2002 PAGE 4 OF 8
JOINT WIND FREQUENCY DISTRIBUTION BY STABILITY CLASS SITE: V. C. SUMMER Nuclear Station UNIT 1 Report Date : 03-02-27 Data Period : 2 5 08:00 to 2 5 10:00 Stability Class: E delta T/ delta z 61->10 m Delta T With Substitution Wind Sensor Height : 10 meter +++ Batch Release Times Only +++
Hours at Each Wind Direction and Speed Wind Wind Speed (miles/hour)
L Meann Direction 0.75- <4 4- <8 8- <13 13- <19 19- 24 >24 Total' Speed N 0 0 0 0 0 0 0 0.00 NNE 0 0 0 0 0 0 0 0.00 NE 0 0 0 0 0 0 0 0.00 ENE 0 0 0 0 0 0 0 0.00 E 0 0 0 0 0 0 0 0.00 ESE 0 0 0 0 0 0 0 0.00 SE 0 0 0 0 0 0 0 0.00 SSE 0 0 0 0 0 0 0 0.00 S 0 0 0 0 0 0 0 0.00 SSW 0 0 0 0 0 0 0 0.00 SW 0 0 0 0 0 0 0 0.00 WSW 0 0 0 0 0 0 0 0.00 W 0 0 0 0 0 0 0 0.00 WNW 0 0 0 0 0 0 0 0.00 NW 0 0 0 0 0 0 0 0.00 NNW 0 0 0 0 0 0 0 0.00 Total 0 0 0 0 0 0 0 Hours of Calm : 0 Hours of Varying Wind Direction : 0 Hours of Missing Data : 0 Hours of Missing Data for All 0 Hours of No Stability Class : 0 Total hours of observation : 3 TABLE 8 THIRD QUARTER 2002 PAGE 5OF 8
JOINT WIND FREQUENCY DISTRIBUTION BY STABILITY CLASS SITE: V. C. SUMMER Nuclear Station UNIT 1 Report Date : 03-02-27 Data Period : 2 5 08:00 to 2 5 10:00 Stability Class: F delta T/ delta z 61->10 m Delta T With Substitution Wind Sensor Height : 10 meter +++ Batch Release Times Only +++
Hours at Each Wind Direction and Speed Wind Wind Speed (miles/hour)
Direction Mean I 0.75- <4 4- <8 8- <13 13- <19 19- 24 >24 TotalJ Speea 0 0 0 0 0 0 0 0.00 N
0 0 0 0 0 0 0 0.00 NNE 0.00 0 0 0 0 0 0 0 NE 0 0 0 0 0 0 0 0.00 ENE 0 0.00 0 0 0 0 0 0 E 0 0 0 0 0 0 0 0.00 ESE 0 0 0.00 SE 0 0 0 0 0 0 0 0 0 0 0 0.00 SSE 0 0 0 0 0 0 0 0 0.00 S 0 0 0.00 SSW 0 0 0 0 0 0 0 0 0 0 0 0.00 SW 0 0 0 0 0 0 0 0 0.00 WSW 0 0.00 0 0 0 0 0 0 W 0 0 0 0 0 0 0 0.00 WNW 0 0 0.00 NW 0 0 0 0 0 0 0 0 0 0 0 0.00 NNW 0 To_________al_________0_______0______0______0_______0______0__
° ° ° ° 0 Total Hours of Calm : 0 Hours of Varying Wind Direction 0 Hours of Missing Data 0 Hours of Missing Data for All 0 Hours of No Stability Class 0 Total hours of observation 3 TABLE 8 THIRD QUARTER 2002 PAGE 60F8
JOINT WIND FREQUENCY DISTRIBUTION BY STABILITY CLASS SITE: V. C. SUMMER Nuclear Station UNIT 1 Report Date : 03-02-27 Data Period : 2 5 08:00 to 2 5 10:00 Stability Class: G delta T/ delta z 61->10 m Delta T With Substitution Wind Sensor Height : 10 meter +++ Batch Release Times Only +++
Hours at Each Wind Direction and Speed Wind Wind Speed (miles/hour)
Direction Mean 0.75- <4 4- <8 8- <13 13- <19 19- 24 >24 Total' Speed N 0 0 0 0 0 0 0 0.00 NNE 0 0 0 0 0 0 0 0.00 NE 0 0 0 0 0 0 0 0.00 ENE 0 0 0 0 0 0 0 0.00 E 0 0 0 0 0 0 0 0.00 ESE 0 0 0 0 0 0 0 0.00 SE 0 0 0 0 0 0 0 0.00 SSE 0 0 0 0 0 0 0 0.00 S 0 0 0 0 0 0 0 0.00 SSW 0 0 0 0 0 0 0 0.00 SW 0 0 0 0 0 0 0 0.00 WSW 0 0 0 0 0 0 0 0.00 W 0 0 0 0 0 0 0 0.00 WNW 0 0 0 0 0 0 0 0.00 NW 0 0 0 0 0 0 0 0.00 NNW 0 0 0 0 0 0 0 0.00 Total 0 0 0 0 0 0 0 Hours of Calm : 0 Hours of Varying Wind Direction : 0 Hours of Missing Data : 0 Hours of Missing Data for All : 0 Hours of No Stability Class : 0 Total hours of observation : 3 TABLE 8 THIRD QUARTER 2002 PAGE 7 OF 8
JOINT WIND FREQUENCY DISTRIBUTION BY STABILITY CLASS SITE: V. C. SUMMER Nuclear Station UNIT 1 Report Date : 03-02-27 Data Period : 2 5 08:00 to 2 5 10:00 Stability Class:ALL delta T/ delta z 61->10 m Delta T With Substitution Wind Sensor Height : 10 meter +++ Batch Release Times Only +++
Hours at Each Wind Direction and Speed Wind Wind Speed (miles/hour) iqA-I1 Direction 0.75- <4 4- <8 8- <13 13- <19 19- 24 >24 Total' Speed N 0 0 0 0 0 0 0 0.00 NNE 0 0 0 0 0 0 0 0.00 NE 0 0 0 0 0 0 0 0.00 ENE 2 0 1 0 0 0 3 5.00 E 0 0 0 0 0 0 0 0.00 0 0 0 0 0 0 0 0.00 ESE SE 0 0 0 a 0 0 0 0.00 SSE 0 0 0 0 0 0 0 0.00 S 0 0 0 0 0 0 0 0.00 SSW 0 0 0 0 0 0 0 0.00 SW 0 0 0 0 0 0 0 0.00 WSW 0 0 0 0 0 0 0 0.00 W 0 0 0 0 0 0 0 0.00 WNW 0 0 0 0 0 0 0 0.00 0 0 0 0 0 0 0 0.00 NW 0 NNW 0 0 0 0 0 0 0.00 Total 2 0 1 0 0 0 3 Hours of Calm 0 Hours of Varying Wind Direction : 0 Hours of Missing Data for All 0 Hours of No Stability Class : 0 Total hours of observation 3 TABLE 8 THIRD QUARTER 2002 PAGE 8 0F 8
JOINT WIND FREQUENCY DISTRIBUTION BY STABILITY CLASS SITE: V. C. SUMMER Nuclear Station UNIT 1 Report Date : 03-02-27 Data Period : 2- 9-10 13:00 to 2- 9-10 16:00 Stability Class: A delta T/ delta z 61->10 m Delta T With Substitution Wind Sensor Height : 10 meter +++ Batch Release Times Only +++
Hours at Each Wind Direction and Speed Wind Wind Speed (miles/hour)
Direction Mean 0.75- <4 4- <8 8- <13 13- <19 19- 24 >24 Total' Speed N 0 0 0 0 0 0 0 0. 00 NNE 0 0 0 0 0 0 0 0. 00 NE 0 0 0 0 0 0 0 0. 00 ENE 0 0 0 0 0 0 0 0. 00 E 0 0 0 0 0 0 0 0. 00 ESE 0 0 0 0 0 0 0 0. 00 SE 0 0 0 0 0 0 0 0.00 SSE 0 0 0 0 0 0 0 0. 00 S 0 0 0 0 0 0 0 0. 00 SSW 0 0 0 0 0 0 0 0. 00 SW 0 0 0 0 0 0 0 0. 00 WSW 0 0 0 0 0 0 0 0. 00 W 0 0 0 0 0 0 0 0. 00 WNW 0 0 0 0 0 0 0 0. 00 NW 0 0 0 0 0 0 0 0. 00 NNW 0 0 0 0 0 0 0 0 .00 Total 0 0 0 0 0 0 0 Hours of Calm : 0 Hours of Varying Wind Direction : 0 Hours of Missing Data : 0 Hours of Missing Data for All : 0 Hours of No Stability Class : 0 Total hours of observation : 4 TABLE 8 THIRD QUARTER 2002 PAGE 1OF8
JOINT WIND FREQUENCY DISTRIBUTION BY STABILITY CLASS SITE: V. C. SUMMER Nuclear Station UNIT 1 Report Date : 03-02-27 Data Period : 2- 9-10 13:00 to 2- 9-10 16:00 Stability Class: B delta T/ delta z 61->10 m Delta T With Substitution Wind Sensor Height : 10 meter +++ Batch Release Times Only +++
Hours at Each Wind Direction and Speed Wind Wind Speed (miles/hour) SIN.-
Direction Total' Speed 0.75- <4 4- <8 8- <13 13- <19 19- 24 >24 0 0 0 0 0 0 0.00 N 0 0 0.00 NNE 0 0 0 0 0 0 0 0 0 0 0 0 0 0.00 NE 0 0.00 ENE 0 0 0 0 0 0 0 0 0 0 0 0 0 0.00 E 0 0.00 ESE 0 0 0 0 0 0 0 0 0 0 0 0 0 0.00 SE 0 0 0.00 SSE 0 0 0 0 0 0 0 0 0 0 0 0.00 S 0 0 0 0 0 0 0 0 0.00 SSW 0 0.00 0 0 0 0 0 0 SW 0 0.00 0 0 0 0 0 0 WSW 0 0 0.00 W 0 0 0 0 0 0 0 0 0 0 0 0.00 WNW 0 0 0 0 0 0 0 0.00 NW 0 0 0 0.00 NNW 0 0 0 0 0
____ota_______________0_______0______0______0_______0______0__
° ° 0 Total ° Hours of Calm 0 Hours of Varying Wind Direction 0 Hours of Missing Data 0 Hours of Missing Data for All 0 Hours of No Stability Class 0 Total hours of observation 4 TABLE 8 THIRD QUARTER 2002 PAGE 2 OF 8
JOINT WIND FREQUENCY DISTRIBUTION BY STABILITY CLASS SITE: V. C. SUMMER Nuclear Station UNIT 1 Report Date : 03-02-27 Data Period : 2- 9-10 13:00 to 2- 9-10 16:00 Stability Class: C delta T/ delta z 61->10 m Delta T With Substitution Wind Sensor Height : 10 meter +++ Batch Release Times Only +++
Hours at Each Wind Direction and Speed Wind__________Wind__________Speed___________(miles/hour)____________________
Wind Wind Speed (miles/hour)
Direction mean 0.75- <4 4- <8 8- <13 13- <19 19- 24 >24 Total' Speed N 0 0 0 0 0 0 0 0.00 NNE 0 0 0 0 0 0 0 0.00 NE 0 0 0 0 0 0 0 0.00 ENE 0 0 0 0 0 0 0 0.00 E 0 0 0 0 0 0 0 0.00 ESE 0 0 0 0 0 0 0 0.00 SE 0 0 0 0 0 0 0 0.00 SSE 0 0 0 0 0 0 0 0.00 S 0 0 0 0 0 0 0 0.00 SSW 0 0 0 0 0 0 0 0.00 SW 0 0 0 0 0 0 0 0.00 WSW 0 0 0 0 0 0 0 0.00 W 0 0 0 0 0 0 0 0.00 WNW 0 0 0 0 0 0 0 0.00 NW 0 0 1 0 0 0 1 9.17 NNW 0 0 2 0 0 0 2 9.44 Tota____________________0_______0_______________0__
Total ° ° 0 0 3 Hours of Calm 0 Hours of Varying Wind Direction 0 Hours of Missing Data 0 Hours of Missing Data for All 0 Hours of No Stability Class 0 Total hours of observation 4 TABLE 8 THIRD QUARTER 2002 PAGE 3 OF 8
JOINT WIND FREQUENCY DISTRIBUTION BY STABILITY CLASS SITE: V. C. SUMMER Nuclear Station UNIT 1 Report Date : 03-02-27 Data Period : 2- 9-10 13:00 to 2- 9-10 16:00 Stability Class: D delta T/ delta z 61->10 m Delta T With Substitution Wind Sensor Height : 10 meter +++ Batch Release Times Only +++
Hours at Each Wind Direction and Speed Wind Wind Speed (miles/hour)
Direction Total' Speed 0.75- <4 4- <8 8- <13 13- <19 19- 24 >24 0 0 0 0 0 0 0.00 N 0 0 0.00 NNE 0 0 0 0 0 0 0 0 0 0 0 0.00 NE 0 0 0 0.00 ENE 0 0 0 0 0 0 0 0 0 0 0 0 0.00 E 0 0 0.00 ESE 0 0 0 0 0 0 0 0 0 0 0 0 0.00 SE 0 0 0 0.00 SSE 0 0 0 0 0 0 0 0 0 0 0 0.00 S 0 0 0 0 0 0 0 0.00 SSW 0 0 0.00 0 0 0 0 0 SW 0 0 0.00 0 0 0 0 0 0 WSW 0 0 0.00 W 0 0 0 0 0 0 0 0 0 0 0 0.00 WNW 0 0 0 0 0 0 0 0 0.00 NW 0 1 9.49 NNW 0 0 1 0 0 0 0 1 0 0 0 1 Total Hours of Calm : 0 Hours of Varying Wind Direction 0 Hours of Missing Data 0 Hours of Missing Data for All : 0 Hours of No Stability Class : 0 Total hours of observation 4 TABLE 8 THIRD QUARTER 2002 PAGE 4 OF 8
JOINT WIND FREQUENCY DISTRIBUTION BY STABILITY CLASS SITE: V. C. SUMMER Nuclear Station UNIT 1 Report Date : 03-02-27 Data Period : 2- 9-10 13:00 to 2- 9-10 16:00 Stability Class: E delta T/ delta z 61->10 m Delta T With Substitution Wind Sensor Height : 10 meter +++ Batch Release Times Only +++
Hours at Each Wind Direction and Speed Wind Wind Speed (miles/hour)
Direction Mean 0.75- <4 4- <8 8- <13 13- <19 19- 24 >24 Total' Speed N 0 0 0 0 0 0 0 0.00 NNE 0 0 0 0 0 0 0 0.00 NE 0 0 0 0 0 0 0 0.00 ENE 0 0 0 0 0 0 0 0.00 E 0 0 0 0 0 0 0 0.00 ESE 0 0 0 0 0 0 0 0.00 SE 0 0 0 0 0 0 0 0.00 SSE 0 0 0 0 0 0 0 0.00 S 0 0 0 0 0 0 0 0.00 SSW 0 0 0 0 0 0 0 0.00 SW 0 0 0 0 0 0 0 0.00 WSW 0 0 0 0 0 0 0 0.00 W 0 0 0 0 0 0 0 0.00 WNW 0 0 0 0 0 0 0 0.00 NW 0 0 0 0 0 0 0 0.00 NNW 0 0 0 0 0 0 0 0.00 Total 0 0 0 0 0 0 0 Hours of Calm : 0 Hours of Varying Wind Direction : 0 Hours of Missing Data : 0 Hours of Missing Data for All : 0 Hours of No Stability Class : 0 Total hours of observation : 4 TABLE 8 THIRD QUARTER 2002 PAGE 50F8
JOINT WIND FREQUENCY DISTRIBUTION BY STABILITY CLASS SITE: V. C. SUMMER Nuclear Station UNIT 1 Report Date 03-02-27 Data Period 2- 9-10 13:00 to 2- 9-10 16:00 Stability Class: F delta T/ delta z 61->10 m Delta T With Substitution Wind Sensor Height : 10 meter +++ Batch Release Times Only +++
Hours at Each Wind Direction and Speed Wind Wind Speed (miles/hour)
Direction Mean I 0.75- <4 4- <8 8- <13 13- <19 19- 24 >24 Total' Speed N 0 0 0 0 0 0 0 0.00 NNE 0 0 0 0 0 0 0 0.00 NE 0 0 0 0 0 0 0 0.00 ENE 0 0 0 0 0 0 0 0.00 E 0 0 0 0 0 0 0 0.00 ESE 0 0 0 0 0 0 0 0.00 SE 0 0 0 0 0 0 0 0.00 SSE 0 0 0 0 0 0 0 0.00 S 0 0 0 0 0 0 0 0.00 SSW 0 0 0 0 0 0 0 0.00 SW 0 0 0 0 0 0 0 0.00 0 0 0 0 0 0 0 0.00 WSW 0 0 0 0 0 0 0 0.00 W
WNW 0 0 0 0 0 0 0 0.00 0 0 0 0 0 0 0 0.00 NW NNW 0 0 0 0 0 0 0 0.00 Total 0 0 0 0 0 0 0 Hours of Calm 0 Hours of Varying Wind Direction 0 Hours of Missing Data 0 Hours of Missing Data for All 0 Hours of No Stability Class 0 Total hours of observation 4 TABLE 8 THIRD QUARTER 2002 PAGE 6 OF 8
JOINT WIND FREQUENCY DISTRIBUTION BY STABILITY CLASS SITE: V. C. SUMMER Nuclear Station UNIT 1 Report Date : 03-02-27 Data Period : 2- 9-10 13:00 to 2- 9-10 16:00 Stability Class: G delta T/ delta z 61->10 m Delta T With Substitution Wind Sensor Height : 10 meter +++ Batch Release Times Only +++
Hours at Each Wind Direction and Speed Wind Wind Speed (miles/hour)
Direction Mean 0.75- <4 4- <8 8- <13 13- <19 19- 24 >24 Total' Speed N 0 0 0 0 0 0 0 0.00 NNE 0 0 0 0 0 0 0 0.00 NE 0 0 0 0 0 0 0 0.00 ENE 0 0 0 0 0 0 0 0.00 E 0 0 0 0 0 0 0 0.00 ESE 0 0 0 0 0 0 0 0.00 SE 0 0 0 0 0 0 0 0.00 SSE 0 0 0 0 0 0 0 0.00 S 0 0 0 0 0 0 0 0.00 SSW 0 0 0 0 0 0 0 0.00 SW 0 0 0 0 0 0 0 0.00 WSW 0 0 0 0 0 0 0 0.00 W 0 0 0 0 0 0 0 0.00 WNW 0 0 0 0 0 0 0 0.00 NW 0 0 0 0 0 0 0 0.00 NNW 0 0 0 0 0 0 0 0.00 Total 0 0 0 0 0 0 0 Hours of Calm : 0 Hours of Varying Wind Direction : 0 Hours of Missing Data : 0 Hours of Missing Data for All : 0 Hours of No Stability Class : 0 Total hours of observation : 4 TABLE 8 THIRD QUARTER 2002 PAGE 7 OF 8
JOINT WIND FREQUENCY DISTRIBUTION BY STABILITY CLASS SITE: V. C. SUMMER Nuclear Station UNIT 1 Report Date : 03-02-27 Data Period : 2- 9-10 13:00 to 2- 9-10 16:00 Stability Class:ALL delta T/ delta z 61->10 m Delta T With Substitution Wind Sensor Height : 10 meter +++ Batch Release Times Only +++
Hours at Each Wind Direction and Speed Wind__________Wind__________Speed___________(miles/hour)______________-_____
-Wind- Wind Speed (miles/hour)
Direction Mean 0.75- <4 4- <8 8- <13 13- <19 19- 24 >24 Total' Speed N 0 0 0 0 0 0 0 0.00 NNE 0 0 0 0 0 0 0 0.00 NE 0 0 0 0 0 0 0 0.00 ENE 0 0 0 0 0 0 0 0.00 E 0 0 0 0 0 0 0 0.00 ESE 0 0 0 0 0 0 0 0.00 SE 0 0 0 0 0 0 0 0.00 SSE 0 0 0 0 0 0 0 0.00 S 0 0 0 0 0 0 0 0.00 SSW 0 0 0 0 0 0 0 0.00 SW 0 0 0 0 0 0 0 0.00 WSW 0 0 0 0 0 0 0 0.00 W 0 0 0 0 0 0 0 0.00 WNW 0 0 0 0 0 0 0 0.00 NW 0 0 1 0 0 0 1 9.17 NNW 0 0 3 0 0 0 3 9.46 Total___________________0_______0_______4_______0_______0_______0_______4___
Total ° ° 4 ° Hours of Calm : 0 Hours of Varying Wind Direction 0 Hours of Missing Data for All 0 Hours of No Stability Class 0 Total hours of observation 4 TABLE 8 THIRD QUARTER 2002 PAGE 8 OF 8
JOINT WIND FREQUENCY DISTRIBUTION BY STABILITY CLASS SITE: V. C. SUMMER Nuclear Station UNIT 1 Report Date : 03-02-27 Data Period : 2 6 11:00 to 2 6 18:00 Stability Class: A delta T/ delta z 61->10 m Delta T With Substitution Wind Sensor Height : 10 meter +++ Batch Release Times Only +++
Hours at Each Wind Direction and Speed Wind Wind Speed (miles/hour)
Direction Mean 0.75- <4 4- <8 8- <13 13- <19 19- 24 >24 Total' Speed N 0 0 0 0 0 0 0 0.00 NNE 0 0 0 0 0 0 0 0.00 NE 0 0 0 0 0 0 0 0.00 ENE 0 0 0 0 0 0 0 0.00 E 0 0 0 0 0 0 0 0.00 ESE 0 0 0 0 0 0 0 0.00 SE 0 0 0 0 0 0 0 0.00 SSE 0 0 0 0 0 0 0 0.00 S 0 0 0 0 0 0 0 0.00 SSW 0 0 0 0 0 0 0 0.00 SW 0 0 0 0 0 0 0 0.00 WSW 0 0 0 0 0 0 0 0.00 W 0 0 0 0 0 0 0 0.00 WNW 0 0 0 0 0 0 0 0.00 NW 0 0 0 0 0 0 0 0.00 NNW 0 0 0 0 0 0 0 0.00 Total 0 0 0 0 0 0 0 Hours of Calm : 0 Hours of Varying Wind Direction 0 Hours of Missing Data : 0 Hours of Missing Data for All : 0 Hours of No Stability Class : 0 Total hours of observation : 8 TABLE 8 FOURTH QUARTER 2002 PAGE 1OF8
JOINT WIND FREQUENCY DISTRIBUTION BY STABILITY CLASS SITE: V. C. SUMMER Nuclear Station UNIT 1 Report Date : 03-02-27 Data Period : 2 6 11:00 to 2 6 18:00 Stability Class: B delta T/ delta z 61->10 m Delta T With Substitution Wind Sensor Height : 10 meter +++ Batch Release Times Only +++
Hours at Each Wind Direction and Speed Wind Wind Speed (miles/hour)
Direction Mean 0.75- <4 4- <8 8- <13 13- <19 19- 24 >24 Total' Speed N 0 0 0 0 0 0 0 0. 00 NNE 0 0 0 0 0 0 0 0. 00 NE 0 0 0 0 0 0 0 0. 00 ENE 0 0 0 0 0 0 0 0. 00 E 0 0 0 0 0 0 0 0. 00 ESE 0 0 0 0 0 0 0 0. 00 SE 0 0 0 0 0 0 0 0. 00 SSE 0 0 0 0 0 0 0 0. 00 S 0 0 0 0 0 0 0 0. 00 SSW 0 0 0 0 0 0 0 0. 00 SW 0 0o 0 0o 0 0 0 0. 00 WSW 0 0 0 0 0 0. 00 0o 0 0 0 0. 00 W 0 0 0 WNW 0 0 0 0 0 0 0 0. 00 NW 0 0 0 0 0 0 0 0. 00 NNW 0 0 0 0 0 0. 00 Total 0 0 0 0 0 0 0 Hours of Calm :
Hours of Varying Wind Direction :
Hours of Missing Data :
Hours of Missing Data for All :
Hours of No Stability Class :
Total hours of observation :8 TABLE 8 FOURTH QUARTER 2002 PAGE 2OF 8
JOINT WIND FREQUENCY DISTRIBUTION BY STABILITY CLASS SITE: V. C. SUMMER Nuclear Station UNIT 1 Report Date : 03-02-27 Data Period : 2 6 11:00 to 2 6 18:00 Stability Class: C delta T/ delta z 61->10 m Delta T With Substitution Wind Sensor Height : 10 meter +++ Batch Release Times Only +++
Hours at Each Wind Direction and Speed Wind Wind Speed (miles/hour)
.Direction MearL 0.75- <4 4- <8 8- <13 13- <19 19- 24 >24 Total' speea N- 0 0 0 0 0 0 0 0.00 NNE 0 0 0 0 0 0 0 0.00 NE 0 0 0 0 0 0 0 0.00 ENE 0 0 0 0 0 0 0 0.00 E 0 0 0 0 0 0 0 0.00 ESE 0 0 0 0 0 0 0 0.00 0 0 0 0 0 0 0 0.00 SE SSE 0 0 0 0 0 0 0 0.00 S 0 0 0 0 0 0 0 0.00 SSW 0 0 0 0 0 0 0 0.00 SW 0 0 0 0 0 0 0 0.00 WSW 0 0 0 0 0 0 0 0.00 W 0 0 0 0 0 0 0 0.00 WNW 0 0 0 0 0 0 0 0.00 NW 0 0 1 0 0 0 1 12.41 NNW 0 0 0 0 0 0 0 0.00 Total 0 0 1 0 0 0 1 Hours of Calm : 0 Hours of Varying Wind Direction : 0 Hours of Missing Data 0 Hours of Missing Data for All 0 Hours of No Stability Class 0 Total hours of observation 8 TABLE 8 FOURTH QUARTER 2002 PAGE 3 OF 8
JOINT WIND FREQUENCY DISTRIBUTION BY STABILITY CLASS SITE: V. C. SUMMER Nuclear Station UNIT 1 Report Date 03-02-27 Data Period : 2 6 11:00 to 2 6 18:00 Stability Class: D delta T/ delta z 61->10 m Delta T With Substitution Wind Sensor Height : 10 meter +++ Batch Release Times Only +++
Hours at Each Wind Direction and Speed Wind Wind Speed (miles/hour)
Direction Mean 0.75- <4 4- <8 8- <13 13- <19 19- 24 >24 Total' Speed N 0 0 0 0 0 0 0 0.00 NNE 0 0 0 0 0 0 0 0.00 NE 0 0 0 0 0 0 0 0.00 ENE 0 0 0 0 0 0 0 0.00 E 0 0 0 0 0 0 0 0.00 ESE 0 0 0 0 0 0 0 0.00 SE 0 0 0 0 0 0 0 0.00 SSE 0 0 0 0 0 0 0 0.00 S 0 0 0 0 0 0 0 0.00 SSW 0 0 0 0 0 0 0 0.00 SW 0 0 0 0 0 0 0 0.00 WSW 0 0 0 0 0 0 0 ° * °o W 0 0 0 0 0 0 0 0.00 WNW 0 0 4 0 0 0 4 12.16 NW 0 0 1 0 0 0 1 9.55 NNW 0 0 0 0 0 0 0 0.00 Total 0 0 5 0 0 0 5 Hours of Calm : 0 Hours of Varying Wind Direction : 0 Hours of Missing Data : 0 Hours of Missing Data for All : 0 Hours of No Stability Class : 0 Total hours of observation 8 TABLE 8 FOURTH QUARTER 2002 PAGE 4 OF 8
JOINT WIND FREQUENCY DISTRIBUTION BY STABILITY CLASS SITE: V. C. SUMMER Nuclear Station UNIT 1 Report Date : 03-02-27 Data Period : 2 6 11:00 to 2 6 18:00 Stability Class: E delta T/ delta z 61->10 m Delta T With Substitution Wind Sensor Height : 10 meter +++ Batch Release Times Only +++
Hours at Each Wind Direction and Speed Wind Wind Speed (miles/hour)
Direction Mean 0.75- <4 4- <8 8- <13 13- <19 19- 24 >24 Total' Speed N 0 0 0 0 0 0 0 0.00 NNE 0 0 0 0 0 0 0 0.00 NE 0 0 0 0 0 0 0 0.00 ENE 0 0 0 0 0 0 0 0.00 E 0 0 0 0 0 0 0 0.00 ESE 0 0 0 0 0 0 0 0.00 SE 0 0 0 0 0 0 0 0.00 SSE 0 0 0 0 0 0 0 0.00 S 0 0 0 0 0 0 0 0.00 SSW 0 0 0 0 0 0 0 0.00 SW 0 0 0 0 0 0 0 0.00 WSW 0 0 0 0 0 0 0 0.00 W 0 0 0 0 0 0 0 0.00 WNW 0 0 0 0 0 0 0 0.00 NW 0 2 0 0 0 0 2 6.34 NNW 0 0 0 0 0 0 0 0.00 Total 0 2 0 0 0 0 2 Hours of Calm 0 Hours of Varying Wind Direction : 0 Hours of Missing Data : 0 Hours of Missing Data for All : 0 Hours of No Stability Class : 0 Total hours of observation : 8 TABLE 8 FOURTH QUARTER 2002 PAGE 5 OF 8
JOINT WIND FREQUENCY DISTRIBUTION BY STABILITY CLASS SITE: V. C. SUMMER Nuclear Station UNIT 1 Report Date : 03-02-27 Data Period : 2 6 11:00 to 2 6 18:00 Stability Class: F delta T/ delta z 61->10 m Delta T With Substitution Wind Sensor Height : 10 meter +++ Batch Release Times Only +++
Hours at Each Wind Direction and Speed Wind Wind Speed (miles/hour)
Direction Mean 0.75- <4 4- <8 8- <13 13- <19 19- 24 >24 Total' Speed N 0 0 0 0 0 0 0 0. 00 NNE 0 0 0 0 0 0 0 0. 00 NE 0 0 0 0 0 0 0 0. 00 ENE 0 0 0 0 0 0 0 0. 00 E 0 0 0 0 0 0 0 0. 00 ESE 0 0 0 0 0 0 0 0. 00 SE 0 0 0 0 0 0 0 0. 00 SSE 0 0 0 0 0 0 0 0. 00 S 0 0 0 0 0 0 0 0. 00 SSW 0 0 0 0 0 0 0 0. 00 SW 0 0 0 0 0 0 0 0 00 WSW 0 0 0 0 0 0 0 0 00 W 0 0 0 0 0 0 0 0. 00 WNW 0 0 0 0 0 0 0 0. 00 NW 0 0 0 0 0 0 0 0. 00 NSW 0 0 0 0 0 0 0 0. 00 Total 0 0 0 0 0 0 0 Hours of Calm : 0 Hours of Varying Wind Direction : 0 Hours of Missing Data : 0 Hours of Missing Data for All : 0 Hours of No Stability Class : 0 Total hours of observation : 8 TABLE 8 FOURTH QUARTER 2002 PAGE 6 OF 8
JOINT WIND FREQUENCY DISTRIBUTION BY STABILITY CLASS SITE: V. C. SUMMER Nuclear Station UNIT 1 Report Date : 03-02-27 Data Period : 2 6 11:00 to 2 6 18:00 Stability Class: G delta T/ delta z 61->10 m Delta T With Substitution Wind Sensor Height : 10 meter +++ Batch Release Times Only +++
Hours at Each Wind Direction and Speed Wind Wind Speed (miles/hour)
Direction Mean 0.75- <4 4- <8 8- <13 13- <19 19- 24 >24 Total' Speed N 0 0 0 0 0 0 0 0.00 NNE 0 0 0 0 0 0 0 0.00 NE 0 0 0 0 0 0 0 0.00 ENE 0 0 0 0 0 0 0 0.00 E 0 0 0 0 0 0 0 0.00 ESE 0 0 0 0 0 0 0 0.00 SE 0 0 0 0 0 0 0 0.00 SSE 0 0 0 0 0 0 0 0.00 S 0 0 0 0 0 0 0 0.00 SSW 0 0 0 0 0 0 0 0.00 SW 0 0 0 0 0 0 0 0.00 WSW 0 0 0 0 0 0 0 0.00 W 0 0 0 0 0 0 0 0.00 WNW 0 0 0 0 0 0 0 0.00 NW 0 0 0 0 0 0 0 0.00 NNW 0 0 0 0 0 0 0 0.00 Total 0 0 0 0 0 0 0 Hours of Calm : 0 Hours of Varying Wind Direction : 0 Hours of Missing Data
- 0 Hours of Missing Data for All : 0 Hours of No Stability Class : 0 Total hours of observation : 8 TABLE 8 FOURTH QUARTER 2002 PAGE 7 OF 8
JOINT WIND FREQUENCY DISTRIBUTION BY STABILITY CLASS SITE: V. C. SUMMER Nuclear Station UNIT 1 Report Date : 03-02-27 Data Period : 2 6 11:00 to 2 6 18:00 Stability Class:ALL delta T/ delta z 61->10 m Delta T With Substitution Wind Sensor Height : 10 meter +++ Batch Release Times Only +++
Hours at Each Wind Direction and Speed Wind Wind Speed (miles/hour)
Direction Mean 0.75- <4 4- <8 8- <13 13- <19 19- 24 >24 Total' Speed N 0 0 0 0 0 0 0 0. 00 NNE 0 0 0 0 0 0 0 0. 00 NE 0 0 0 0 0 0 0. 00 ENE 0 0o 0 0o 0 0 0 0. 00 E 0 0 0o 0 0 0 0. 00 ESE 0 0 0 0 0 0 0. 00 SE 0 0o 0 0 0 0 0 0. 00 SSE 0 0o 0 0 0 0 0. 00 S 0 0 0 0 0 0 0. 00 0 0 0 0. 00 SSW 0 0 0o 0 SW 0 2 0 0 0 0 0. 00 WSW 0 0 0 0 0 0 0 0. 00 W 0 0 0 0 0 0 0. 00 WNW 0 4 0o 0 0 4 12.16 NW 0 2 0 0 4 8. 66 NNW 0 0 0 0 0 0. 00 Total 0 2 6 0 0 0 8 Hours of Calm :
Hours of Varying Wind Direction :
Hours of Missing Data for All :
Hours of No Stability Class :
Total hours of observation :8 TABLE 8 FOURTH QUARTER 2002 PAGE 8 OF 8
JOINT WIND FREQUENCY DISTRIBUTION BY STABILITY CLASS SITE: V. C. SUMMER Nuclear Station UNIT 1 Report Date : 03-02-27 Data Period : 2-11-18 14:00 to 2-11-18 16:00 Stability Class: A delta T/ delta z 61->10 m Delta T With Substitution Wind Sensor Height : 10 meter +++ Batch Release Times Only +++
Hours at Each Wind Direction and Speed Wind Wind Speed (miles/hour)
Direction Mean 0.75- <4 4- <8 8- <13 13- <19 19- 24 >24 Total' Speed N 0 0 0 0 0 0 0 0.00 NNE 0 0 0 0 0 0 0 0.00 NE 0 0 0 0 0 0 0 0.00 ENE 0 0 0 0 0 0 0 0.00 E 0 0 0 0 0 0 0 0.00 ESE 0 0 0 0 0 0 0 0.00 SE 0 0 0 0 0 0 0 0.00 SSE 0 0 0 0 0 0 0 0.00 S 0 0 0 0 0 0 0 0.00 SSW 0 0 0 0 0 0 0 0.00 SW 0 0 0 0 0 0 0 0.00 WSW 0 0 0 0 0 0 0 0 00 W 0 0 0 0 0 0 0 0.00 WNW 0 0 0 0 0 0 0 0.00 NW 1 0 0 0 0 0 1 3.16 NNW 0 0 0 0 0 0 0 0.00 Total 1 0 0 0 0 0 1 Hours of Calm : 0 Hours of Varying Wind Direction : 0 Hours of Missing Data : 0 Hours of Missing Data for All : 0 Hours of No Stability Class : 0 Total hours of observation : 3 TABLE 8 FOURTH QUARTER 2002 PAGE 1OF8
JOINT WIND FREQUENCY DISTRIBUTION BY STABILITY CLASS SITE: V. C. SUMMER Nuclear Station UNIT 1 Report Date : 03-02-27 Data Period : 2-11-18 14:00 to 2-11-18 16:00 Stability Class: B delta T/ delta z 61->10 m Delta T With Substitution Wind Sensor Height : 10 meter +++ Batch Release Times Only +++
Hours at Each Wind Direction and Speed Wind Wind Speed (miles/hour)
Direction Mean 0.75- <4 4- <8 8- <13 13- <19 19- 24 >24 Total' Speed N 0 0 0 0 0 0 0 0.00 NNE 0 0 0 0 0 0 0 0.00 NE 0 0 0 0 0 0 0 0.00 ENE 0 0 0 0 0 0 0 0.00 E 0 0 0 0 0 0 0 0.00 ESE 0 0 0 0 0 0 0 0.00 SE 0 0 0 0 0 0 0 0.00 SSE 0 0 0 0 0 0 0 0.00 S 0 0 0 0 0 0 0 0.00 SSW 0 0 0 0 0 0 0 0.00 SW 0 0 0 0 0 0 0 0.00 WSW 0 0 0 0 0 0 0 0.00 W 0 0 0 0 0 0 0 0.00 WNW 0 0 0 0 0 0 0 0.00 NW 1 0 0 0 0 0 1 3.31 NNW 0 0 0 0 0 0 0 0.00 Total 1 0 0 0 0 0 1 Hours of Calm : 0 Hours of Varying Wind Direction : 0 Hours of Missing Data : 0 Hours of Missing Data for All : 0 Hours of No Stability Class : 0 Total hours of observation : 3 TABLE 8 FOURTH QUARTER 2002 PAGE 2 OF 8
JOINT WIND FREQUENCY DISTRIBUTION BY STABILITY CLASS SITE: V. C. SUMMER Nuclear Station UNIT 1 Report Date : 03-02-27 Data Period : 2-11-18 14:00 to 2-11-18 16:00 Stability Class: C delta T/ delta z 61->10 m Delta T With Substitution Wind Sensor Height : 10 meter +++ Batch Release Times Only +++
Hours at Each Wind Direction and Speed Wind Wind Speed (miles/hour)
L-i"1 Cl X Direction 0.75- <4 4- <8 8- <13 13- <19 19- 24 >24 Total' Speed
_ _ _ _ _ _ _0__ _ _ _ _0__ _ _ _ _0__ _ _ _ _0__ _ _ _0__ _ _ _ _0_ _ 0 0.00 N 0 0 0 0 0 0 0 0 0 0 0 0 0.00 NNE 0 0 0 0 0 0 0 0.00 NE 0 0 0 0 0 0 0 0.00 ENE 0 0 0 0 0 0 0 0.00 E 0 0 0 0 0 0 0 0.00 ESE 0 0 0 0 0 0 0 0.00 SE 0 0.00 0 0 0 0 0 0 SSE 0 0.00 0 0 0 0 0 0 S 0 0 0 0 0 0 0 0.00 SSW 0 0 0 0 0 0 0 0.00 SW 0 0 0 0 0 0 0 0.00 WSW 0 0 0 0 0 0 0 0.00 W 0 0 0 0 0 0 0 0.00 WNW 0
° ° ° ° ° 0 0.00 NW 0 0 0 0 0 0 0 0.00 NNW 0 0 0 0 0 0 0 Total 0 Hours of Calm : 0 Hours of Varying Wind Direction 0 Hours of Missing Data 0 Hours of Missing Data for All : 0 Hours of No Stability Class : 0 Total hours of observation 3 TABLE 8 FOURTH QUARTER 2002 PAGE 3 OF 8
JOINT WIND FREQUENCY DISTRIBUTION BY STABILITY CLASS SITE: V. C. SUMMER Nuclear Station UNIT 1 Report Date : 03-02-27 Data Period : 2-11-18 14:00 to 2-11-18 16:00 Stability Class: D delta T/ delta z 61->10 m Delta T With Substitution Wind Sensor Height : 10 meter +++ Batch Release Times Only +++
Hours at Each Wind Direction and Speed Wind Wind Speed (miles/hour)
Direction Mean I 0.75- <4 4- <8 8- <13 13- <19 19- 24 >24 Total' Speed N 0 0 0 0 0 0 0 0. 00 NNE 0 0 0 0 0 0 0 0. 00 NE 0 0 0 0 0 0 0 0. 00 ENE 0 0 0 0 0 0 0 0. 00 E 0 0 0 0 0 0 0. 00 0 0 0 0 0 0. 00 ESE 0 0 SE 0 0 0 0 0' 0 0.00 SSE 0 0 0 0 0 0 0. 00 0 0 0 0 0 0. 00 S 0 0 0 0 0 0 0 0. 00 SSW 0 0 SW 0 0 0 0o 0 0 0 0. 00 WSW 1 0 0 0 0 1 2.22 0o 0 0 0. 00 W 0 0 0 0 WNW 0 0 0 0 0 0 0. 00 NW 0 0 0 0 0 0 0. 00 NNW 0 0 0 0 0 0. 00 Total 1 0 0 0 0 0 1 Hours of Calm :
Hours of Varying Wind Direction :
Hours of Missing Data :
Hours of Missing Data for All :
Hours of No Stability Class :
Total hours of observation :3 TABLE 8 FOURTH QUARTER 2002 PAGE 4OF 8
JOINT WIND FREQUENCY DISTRIBUTION BY STABILITY CLASS SITE: V. C. SUMMER Nuclear Station UNIT 1 Report Date : 03-02-27 Data Period : 2-11-18 14:00 to 2-11-18 16:00 Stability Class: E delta T/ delta z 61->10 m Delta T With Substitution Wind Sensor Height : 10 meter +++ Batch Release Times Only +++
Hours at Each Wind Direction and Speed Wind Wind Speed (miles/hour)
Direction Mean 0.75- <4 4- <8 8- <13 13- <19 19- 24 >24 Total' Speed N 0 0 0 0 0 0 0 0.00 NNE 0 0 0 0 0 0 0 0.00 NE 0 0 0 0 0 0 0 0.00 0 0 0 0 0 0 0.00 ENE 0 0
E 0 0 0 0 0 0 0.00 ESE 0 0 0 0 0 0 0 0.00 SE 0 0 0 0 0 0 0 0.00 0 0 0 0 0 0 0.00 SSE 0 0
S 0 0 0 0 0 0 0.00 SSW 0 0 0 0 0 0 0 0.00 SW 0 0 0 0 0 0 0 0.00 WSW 0 0 0 0 0 0 0 0.00 0 0 0 0 0 0 0.00 W 0 WNW 0 0 0 0 0 0 0 0.00 NW 0 0 0 0 0 0 0 0.00 0 0 0 0 0 0 0 0.00 NNW Total 0 0 0 0 0 0 0 Hours of Calm 0 Hours of Varying Wind Direction 0 Hours of Missing Data 0 Hours of Missing Data for All 0 Hours of No Stability Class 0 Total hours of observation 3 TABLE 8 FOURTH QUARTER 2002 PAGE 50F8
JOINT WIND FREQUENCY DISTRIBUTION BY STABILITY CLASS SITE: V. C. SUMMER Nuclear Station UNIT 1 Report Date : 03-02-27 Data Period : 2-11-18 14:00 to 2-11-18 16:00 Stability Class: F delta T/ delta z 61->10 m Delta T With Substitution Wind Sensor Height : 10 meter +++ Batch Release Times Only +++
Hours at Each Wind Direction and Speed Wind Wind Speed (miles/hour)
Direction Mean 0.75- <4 4- <8 8- <13 13- <19 19- 24 >24 Total' Speed N 0 0 0 0 0 0 0 0. 00 NNE 0 0 0 0 0 0 0 0. 00 NE 0 0 0 0 0 0 0 0. 00 ENE 0 0 0 0 0 0 0 0. 00 E 0 0 0 0 0 0 0 0. 00 ESE 0 0 0 0 0 0 0 0.00 SE 0 0 0 0 0 0 0 0. 00 SSE 0 0 0 0 0 0 0 0. 00 S 0 0 0 0 0 0 0. 00 SSW 0 0 0 0 0 0 0 0. 00 SW 0 0 0 0 0 0 0. 00 0o 0 0 0 0 0. 00 WSW 0 0 W 0 0 0 0 0 0 0. 00 0 0 0 0 0 0. 00 WNW 0 0 NW 0 0 0 0 0 0 0. 00 NNW 0 0 0 0 0 0 0. 00 Total 0 0 0 0 0 0 0 Hours of Calm :
Hours of Varying Wind Direction :
Hours of Missing Data :
Hours of Missing Data for All :
Hours of No Stability Class :
Total hours of observation :3 TABLE 8 FOURTH QUARTER 2002 PAGE 6 OF 8
JOINT WIND FREQUENCY DISTRIBUTION BY STABILITY CLASS SITE: V. C. SUMMER Nuclear Station UNIT 1 Report Date : 03-02-27 Data Period : 2-11-18 14:00 to 2-11-18 16:00 Stability Class: G delta T/ delta z 61->10 m Delta T With Substitution Wind Sensor Height : 10 meter .++ Batch Release Times Only +++
Hours at Each Wind Direction and Speed Wind Wind Speed (miles/hour)
Direction 0.75- <4 4- <8 8- <13 13- <19 19- 24 >24 Total' Speed N 0 0 0 0 0 0 0 0.00 NNE 0 0 0 0 0 0 0 0.00 NE 0 0 0 0 0 0 0 0.00 ENE 0 0 0 0 0 0 0 0.00 E 0 0 0 0 0 0 0 0.00 ESE 0 0 0 0 0 0 0 0.00 SE 0 0 0 0 0 0 0 0.00 SSE 0 0 0 0 0 0 0 0.00 S 0 0 0 0 0 0 0 0.00 SSW 0 0 0 0 0 0 0 0.00 SW 0 0 0 0 0 0 0 0.00 WSW 0 0 0 0 0 0 0 0.00 W 0 0 0 0 0 0 0 0.00 WNW 0 0 0 0 0 0 0 0.00 NW 0 0 0 0 0 0 0 0.00 NNW 0 0 0 0 0 0 0 0.00 Total 0 0 0 0 0 0 0 Hours of Calm : 0 Hours of Varying Wind Direction 0 Hours of Missing Data : 0 Hours of Missing Data for All : 0 Hours of No Stability Class 0 Total hours of observation 3 TABLE 8 FOURTH QUARTER 2002 PAGE 7 OF 8
JOINT WIND FREQUENCY DISTRIBUTION BY STABILITY CLASS SITE: V. C. SUMMER Nuclear Station UNIT 1 Report Date : 03-02-27 Data Period : 2-11-18 14:00 to 2-11-18 16:00 Stability Class:ALL delta T/ delta z 61->10 m Delta T With Substitution Wind Sensor Height : 10 meter +++ Batch Release Times Only +++
Hours at Each Wind Direction and Speed Wind Wind Speed (miles/hour)
Direction Mean 0.75- <4 4- <8 8- <13 13- <19 19- 24 >24 Total' Speed N 0 0 0 0 0 0 0 0.00 NNE 0 0 0 0 0 0 0 0.00 NE 0 0 0 0 0 0 0 0.00 ENE 0 0 0 0 0 0 0 0.00 E 0 0 0 0 0 0 0 0.00 ESE 0 0 0 0 0 0 0 0.00 SE 0 0 0 0 0 0 0 0.00 SSE 0 0 0 0 0 0 0 0.00 S 0 0 0 0 0 0 0 0.00 SSW 0 0 0 0 0 0 0 0.00 SW 0 0 0 0 0 0 0 0.00 WSW 1 0 0 0 0 0 1 2.22 W 0 0 0 0 0 0 0 0.00 WNW 0 0 0 0 0 0 0 0.00 NW 2 0 0 0 0 0 2 3.23 NNW 0 0 0 0 0 0 0 0.00 Total 3 0 0 0 0 0 3 Hours of Calm 0 Hours of Varying Wind Direction : 0 Hours of Missing Data for All : 0 Hours of No Stability Class : 0 Total hours of observation 3 TABLE 8 FOURTH QUARTER 2002 PAGE 8 OF 8
JOINT WIND FREQUENCY DISTRIBUTION BY STABILITY CLASS SITE: V. C. SUMMER Nuclear Station UNIT 1 Report Date : 03-02-27 Data Period : 2-12-14 12:00 to 2-12-14 17:00 Stability Class: A delta T/ delta z 61->10 m Delta T With Substitution Wind Sensor Height : 10 meter +++ Batch Release Times Only +++
Hours at Each Wind Direction and Speed Wind Wind Speed (miles/hour)
Direction Mean 0.75- <4 4- <8 8- <13 13- <19 19- 24 >24 Total' Speed 0 0 0 0 0 0. 00 N 0 NNE 0o 0 0 0 0 0. 00 0 0 0 0 0 0. 00 NE 0 ENE 0 D 0 0 0. 00 0 0o 0 0 0 0. 00 E 0 0 0 0 0 0 0 0 0. 00 ESE 0 SE 0 0 0 0o 0 0 0. 00 0o 0 0 0 0 0 0. 00 SSE 0 S
0 0 0 0 0 0 0. 00 0 0 0 0 0 0 0. 00 SSW 0o 0 SW 0 0 0 0 0 0. 00 0 0 0 0 0 0 0 . 00 WSW 0 W
0 0 0 0 0 0. 00 WNW 0 0 0 0 0 0. 00 0 0 0 0 0. 00 NW 0 0 0 0. 00 NNW 0 Total 0 0 0 0 0 Hours of Calm :
Hours of Varying Wind Direction :
Hours of Missing Data :
Hours of Missing Data for All :
Hours of No Stability Class :
Total hours of observation :6 TABLE 8 FOURTH QUARTER 2002 PAGE 1 OF 8
JOINT WIND FREQUENCY DISTRIBUTION BY STABILITY CLASS SITE: V. C. SUMMER Nuclear Station UNIT 1 Report Date : 03-02-27 Data Period : 2-12-14 12:00 to 2-12-14 17:00 Stability Class: B delta T/ delta z 61->10 m Delta T With Substitution Wind Sensor Height : 10 meter +++ Batch Release Times Only .++
Hours at Each Wind Direction and Speed Wind Wind Speed (miles/hour) AN S 2 2t 9=C I Direction 0.75- <4 4- <8 8- <13 13- <19 19- 24 >24 Total' Speed
_ _ _0__ _ _ _0__ _ _ _0__ _ _ _0__ _ _ _0__ _ _ _0_ _
N__ 0 0 0 0.00 N 0 0 0 0 0 0 0 0 0 0 0 0.00 NNE 0.00 0 0 0 0 0 0 0 NE 0 0.00 ENE 0 0 0 0 0 0 0 0 0 0 0 0 0.00 E 0 0 0 0 0 0 0 0.00 ESE 0 0 0 0 0 0 0 0.00 SE 0 0 0 0 0 0 0 0.00 SSE 0 0.00 0 0 0 0 0 0 0 S
0 0 0 0 0 0 0.00 SSW 0 0 0 0 0 0 0 0.00 SW 0 0 0 2 0 0 0 0 0.00 WSW 0 0 2 0 0 0 2 11.38 W 9.85 0 0 1 0 0 0 1 WNW 0 0.00 NW 0 0 0 0 0 0 0 0 3 0 0 0 0 0.00 NNW Total ° 3 Hours of Calm 0 Hours of Varying Wind Direction 0 Hours of Missing Data 0 Hours of Missing Data for All 0 Hours of No Stability Class 0 Total hours of observation 6 TABLE 8 FOURTH QUARTER 2002 PAGE 2 OF 8
JOINT WIND FREQUENCY DISTRIBUTION BY STABILITY CLASS SITE: V. C. SUMMER Nuclear Station UNIT 1 Report Date : 03-02-27 Data Period : 2-12-14 12:00 to 2-12-14 17:00 Stability Class: C delta T/ delta z 61->10 m Delta T With Substitution Wind Sensor Height : 10 meter +++ Batch Release Times Only +++
Hours at Each Wind Direction and Speed Wind Wind Speed (miles/hour)
Direction mean 0.75- <4 4- <8 8- <13 13- <19 19- 24 >24 Total' Speed N 0 0 0 0 0 0 0 0.00 NNE 0 0 0 0 0 0 0 0.00 NE 0 0 0 0 0 0 0 0.00 ENE 0 0 0 0 0 0 0 0.00 E 0 0 0 0 0 0 0 0.00 ESE 0 0 0 0 0 0 0 0.00 SE 0 0 0 0 0 0 0 0.00 SSE 0 0 0 0 0 0 0 0.00 S 0 0 0 0 0 0 0 0.00 SSW 0 0 0 0 0 0 0 0.00 SW 0 0 0 0 0 0 0 0.00 WSW 0 0 0 0 0 0 0 0.00 W 0 0 0 0 0 0 0 0.00 WNW 0 0 0 0 0 0 0 0.00 NW 0 0 0 0 0 0 0 0.00 NNW 0 0 0 0 0 0 0 0.00 Tota____________________0_______0_______0_______0___
Total ° ° 0 0 0 Hours of Calm 0 Hours of Varying Wind Direction 0 Hours of Missing Data 0 Hours of Missing Data for All 0 Hours of No Stability Class 0 Total hours of observation 6 TABLE 8 FOURTH QUARTER 2002 PAGE 3 OF 8
JOINT WIND FREQUENCY DISTRIBUTION BY STABILITY CLASS SITE: V. C. SUMMER Nuclear Station UNIT 1 Report Date : 03-02-27 Data Period : 2-12-14 12:00 to 2-12-14 17:00 Stability Class: D delta T/ delta z 61->10 m Delta T With Substitution Wind Sensor Height : 10 meter +++ Batch Release Times Only +++
Hours at Each Wind Direction and Speed Wind Wind Speed (miles/hour)
Direction _
I - - - A Mean A 0.75- <4 4- <8 8- <13 13- <19 1LY- Z4 >zq LoaLc- ;j==u 0 0 0 0 0 0 0 0.00 N
0 0 0 0 0 0 0 0.00 NNE 0 0 0 0 0 0 0 0.00 NE 0 0 0 0 0 0 0 0.00 ENE 0.00 0 0 0 0 0 0 0 E 0.00 0 0 0 0 0 0 0 ESE 0.00 0 0 0 0 0 0 0 SE 0 0 0 0 0 0 0 0.00 SSE 0 0 0 0 0 0 0 0.00 S 0.00 0 0 0 0 0 0 0 SSW 0 0 0 0 0 0 0.00 SW 0 0 0 0 0 0 0 0 0.00 WSW 8.75 0 0 1 0 0 0 1 W 7.67 WNW 0 1 0 0 0 2 0 0 0 0 0 0 0.00 NW 0 0 0 0 0 0 0 0.00 NNW 0 0 1 2 0 0 0 3 Total Hours of Calm 0 Hours of Varying Wind Direction 0 Hours of Missing Data 0 Hours of Missing Data for All 0 Hours of No Stability Class 0 Total hours of observation 6 TABLE 8 FOURTH QUARTER 2002 PAGE 4 OF 8
JOINT WIND FREQUENCY DISTRIBUTION BY STABILITY CLASS SITE: V. C. SUMMER Nuclear Station UNIT 1 Report Date : 03-02-27 Data Period : 2-12-14 12:00 to 2-12-14 17:00 Stability Class: E delta T/ delta z 61->10 m Delta T With Substitution Wind Sensor Height : 10 meter +++ Batch Release Times Only +++
Hours at Each Wind Direction and Speed Wind Wind Speed (miles/hour)
Direction _ - A
~A 1L.L-M-6 If Mean C aa A4 0.75- <4 4- <8 8- <13 13- <19 1Y0- Id >z c e-0 0 0 0 0 0 0.00 N 0 0 0 0 0 0 0 0.00 NNE 0 0 0 0 0.00 NE 0 0 0 0 0 0 0 0 0 0 0.00 ENE 0 0 0 0.00 0 0 0 0 E 0 0 0 0 0.00 ESE 0 0 0 0 0 0 0 0 0 0.00 SE 0 0 0 0 0 0 0 0 0.00 SSE 0 0 0 0 0.00 S 0 0 0 0 0 0 0 0 0 0 0.00 SSW 0 0 0 0 0.00 SW 0 0 0 0 0 0 0 0 0 0 0.00 WSW 0 0 0 0 0.00 W 0 0 0 0 0 0 0 0 0 0.00 WNW 0 0 0 NW n 0 0 0 0 0 0.00 NNW 0 0 0 0 0 0 0 0.00 0 0 0 0 0 Total 0 0 Hours of Calm 0 Hours of Varying Wind Direction 0 Hours of Missing Data 0 Hours of Missing Data for All 0 Hours of No Stability Class 0 Total hours of observation 6 TABLE 8 FOURTH QUARTER 2002 PAGE 5 OF&
JOINT WIND FREQUENCY DISTRIBUTION BY STABILITY CLASS SITE: V. C. SUMMER Nuclear Station UNIT 1 Report Date : 03-02-27 1 Data Period : 2-12-14 12:00 to 2-12-14 17:00 Stability Class: F delta T/ delta z 61->10 m Delta T With Substitution Wind Sensor Height : 10 meter +++ Batch Release Times Only +++
Hours at Each Wind Direction and Speed Wind Wind Speed (miles/hour)
Direction MeanL 0.75- <4 4- <8 8- <13 13- <19 19- 24 >24 Total' speea N 0 0 0 0 0 0 0 0.00 NNE 0 0 0 0 0 0 0 0.00 NE 0 0 0 0 0 0 0 0.00 ENE 0 0 0 0 0 0 0 0.00 E 0 0 0 0 0 0 0 0.00 ESE 0 0 0 0 0 0 0 0.00 SE 0 0 0 0 0 0 0 0.00 SSE 0 0 0 0 0 0 0 0.00 S 0 0 0 0 0 0 0 0.00 SSW 0 0 0 0 0 0 0 0.00 SW 0 0 0 0 0 0 0 0.00 WSW 0 0 0 0 0 0 0 0.00 W 0 0 0 0 0 0 0 0.00 WNW 0 0 0 0 0 0 0 0.00 NW 0 0 0 0 0 0 0 0.00 NNW 0 0 0 0 0 0 0 0.00 Tota____________________0______0_______0_______0__
Total ° ° ° 0 0 0 Hours of Calm : 0 Hours of Varying Wind Direction : 0 Hours of Missing Data 0 Hours of Missing Data for All : 0 Hours of No Stability Class 0 Total hours of observation 6 TABLE 8 FOURTH QUARTER 2002 PAGE 6 OF 8
JOINT WIND FREQUENCY DISTRIBUTION BY STABILITY CLASS SITE: V. C. SUMMER Nuclear Station UNIT 1 Report Date : 03-02-27 Data Period : 2-12-14 12:00 to 2-12-14 17:00 Stability Class: G delta T/ delta z 61->10 m Delta T With Substitution Wind Sensor Height : 10 meter +++ Batch Release Times Only +++
Hours at Each Wind Direction and Speed Wind Wind Speed (miles/hour)
Mean Direction 0.75- <4 4- <8 8- <13 13- <19 19- 24 >24 Total' Speed 0 0 0 0 0 0 0.00 N 0 0 0 0 0 0 0 0.00 NNE 0 0 0 0 0 0 0 0.00 NE 0 0 0 0 0 0 0 0.00 ENE 0 0 0 0 0 0 0 0.00 E 0 0.00 0 0 0 0 0 0 ESE 0 0 0 0 0 0 0 0.00 SE 0 0 0 0 0 0 0 0.00 SSE 0 0.00 0 0 0 0 0 0 S 0 0 0 0 0 0 0 0.00 SSW 0 0 0 0 0 0 0 0.00 SW 0 0 0 0 0 0 0 0.00 WSW 0 0 0 0 0 0 0 0.00 W 0 0 0 0 0 0 0.00 WNW 0 0 0 0 0 0 0 0 0.00 NW 0 0 0. 0 0 0 0.00 NNW 0 0 0 0 0 0 0 Total 0 0 of Calm 0 Hours Hours of Varying Wind Direction 0 Hours of Missing Data 0 Hours of Missing Data for All 0 Hours of No Stability Class 0 Total hours of observation 6 TABLE 8 FOURTH QUARTER 2002 PAGE 7 OF 8
JOINT WIND FREQUENCY DISTRIBUTION BY STABILITY CLASS SITE: V. C. SUMMER Nuclear Station UNIT 1 Report Date : 03-02-27 Data Period : 2-12-14 12:00 to 2-12-14 17:00 Stability Class:ALL delta T/ delta z 61->10 m Delta T With Substitution Wind Sensor Height : 10 meter +++ Batch Release Times Only ++.
Hours at Each Wind Direction and Speed Wind Wind Speed (miles/hour)
Direction Mean 1, 0.75- <4 4- <8 8- <13 13- <19 19- 24 >24 Total' Speed N 0 0 0 0 0 0 0 0. 00 NNE 0 0 0 0 0 0 0 0. 00 NE 0 0 0 0 0 0 0 0. 00 ENE 0 oo0 0 0 0 0 0 0. 00 E 0 0 0 0 0 0 0 0 .00 ESE 0 0 0 0 0 0 0 0. 00 SE 0 0 0 0 0 0 0 0. 00 SSE 0 0 0 0 0 0 0 0. 00 S 0 0 0 0 0 0 0. 00 SSW 0 0 0 0 0 O0 0. 00 SW 0 0o 0 0 0 0 0 0. 00 WSW 0 0 0 0 0 0 0. 00 W 0 0 3 0 0 0 3 10. 51 WNW 0 2 0 0 0 3 8.40 NW 0 0 0 0 0 0 0. 00 NNW 0 0 0 0 0 0 0. 00 Total 0 1 5 0 0 0 6 Hours of Calm :
Hours of Varying Wind Direction :
Hours of Missing Data for All :
Hours of No Stability Class :
Total hours of observation :6 TABLE 8 FOURTH QUARTER 2002 PAGE 8 OF 8
JOINT WIND FREQUENCY DISTRIBUTION BY STABILITY CLASS SITE: V. C. SUMMER Nuclear Station UNIT 1 Report Date : 03-02-27 Data Period : 2-12-16 09:00 to 2-12-16 12:00 Stability Class: A delta T/ delta z 61->10 m Delta T With Substitution Wind Sensor Height : 10 meter +++ Batch Release Times Only +++
Hours at Each Wind Direction and Speed Wind Wind Speed (miles/hour)
Mean .4 Direction 0.75- <4 4- <8 8- c13 13- <19 19- 24 >Z1% I~local' p N_0___0_0_0_0_0_0.00 0 0 0 0 0 0.00 N 0 0 NNE 0 0 0 0 0 0 0 0.00 ENE 0 0 0 0 0 0 0 0 0 0.00 0.00 ENE 0 0 0 0 0 0 0 0 0 0 0 0 0.00 E
ESE 0 0 0 0 0 0 0 0.00 0 0 0 0 0 0 0 0.00 SE 0.00 SSE 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0.00 S
0 0 0 0 0 0 0 0.00 SSW O0 0, 00 WSW 0 SW 0 0O 0 O 0 0 0 0'..00 0 0 0 0 0 0 0.00 W 0 0 0 0 0 0 0 0 0.00 WNW 0.00 0 0 0 0 0 0 0 NW NNW 0 0 0 0 0 0 0 0.00 Total 0 0 0 0 0 0 0 of Calm 0 Hours Hours of Varying Wind Direction 0 Hours of Missing Data 0 Hours of Missing Data for All 0 Hours of No Stability Class 0 Total hours of observation 4 TABLE 8 FOURTH QUARTER 2002 PAGE 10F8
JOINT WIND FREQUENCY DISTRIBUTION BY STABILITY CLASS SITE: V. C. SUMMER Nuclear Station UNIT 1 Report Date : 03-02-27 Data Period : 2-12-16 09:00 to 2-12-16 12:00 Stability Class: B delta T/ delta z 61->10 m Delta T With Substitution Wind Sensor Height : 10 meter +++ Batch Release Times Only +++
Hours at Each Wind Direction and Speed Wind Wind Speed (miles/hour)
_ - ItA Mean A Direction 8- <13 13 - <19 1Y - ;zak >
0.75- <4 4- <8 Li god BUGLGY.L"L~
N__ _ - -__ _ _ _ _0-_ _ _ _ _ _ _ _ _ _ _0--
_ _ _ _ _ _ _ 0 0 0 0 0 0.00 N 0 0 0 0 0 0 0 0 0.00 NNE 0 0 0.00 0 0 0 0 0 NE 0 0 0 0.00 ENE 0 0 0 0 0 0 0 0 0 0 0.00 E 0 0 0 0 0 0 0 0 0.00 ESE 0 0 0 0.00 0 0 0 0 0 0 SE 0 0.00 SSE 0 0 0 0 0 0 0 0 0 0 0.00 S 0 0 0 0 0 0 0 0 0.00 SSW 0 0 0 0 0 0 0.00 SW 0 0 0 0 0 0 0 1 5.27 WSW 0 1 0 0 0 0 0 0.00 W 0 0 0 0 0 0 0.00 WNW 0 0 0 0 0 0 0 0.00 NW 0 0 0 0 0 0 0 0.00 NNW 0 0 0 ____________
0 0 0 1 Total 0 1 0 of Calm 0 Hours 0 Hours of Varying Wind Direction of Missing Data 0 Hours 0 Hours of Missing Data for All of No Stability Class 0 Hours 4 Total hours of observation TABLE 8 FOURTH QUARTER 2002 PAGE 2 OF 8
JOINT WIND FREQUENCY DISTRIBUTION BY STABILITY CLASS SITE: V. C. SUMMER Nuclear Station UNIT 1 Report Date : 03-02-27 Data Period : 2-12-16 09:00 to 2-12-16 12:00 Stability Class: C delta T/ delta z 61->10 m Delta T With Substitution Wind Sensor Height : 10 meter +++ Batch Release Times Only +++
Hours at Each Wind Direction and Speed Wind Wind Speed (miles/hour)
~A , , Mean A1 Direction A 8- <13 13- <cl ZIA
'%A C"=-.
0.75- <4 4- <8 +/ > .+/- lOLd
% L VL e
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ -_0_0 N__ 0 0 0 0 0 0 0.00 N 0 0 0 0.00 0 0 0 0 0 NNE 0 0 0 0.00 NE 0 0 0 0 0 0 0 0 0 0 0.00 ENE 0 0 0 0.00 0 0 0 0 0 E 0 0 0 0.00 ESE 0 0 0 0 0 0 0 0 0 0 0.00 SE 0 0 0.00 0 0 0 0 0 SSE 0 0 0 0.00 0
0 0 0 0 0 0.00 SSW 0 0 0 0 0 0 0 0.00 SW 0 0 0 0 0 0 0 0 0.00 WSW 0 0 0 0.00 0 0 0 0 0 W 0 0 0.00 0 0 0 0 0 WNW 0 0 0 0.00 NW 0 0 0 0 0 0 0 0 0.00 NNW 0 0 0 0_________
0 0 0 0 Total 0 0 0 0
Hours of Calm 0 Hours of Varying Wind Direction 0 Hours of Missing Data 0 Hours of Missing Data for All 0 Hours of No Stability Class 4 Total hours of observation TABLE 8 FOURTH QUARTER 2002 PAGE 3 OF8
JOINT WIND FREQUENCY DISTRIBUTION BY STABILITY CLASS SITE: V. C. SUMMER Nuclear Station UNIT 1 Report Date : 03-02-27 Data Period : 2-12-16 09:00 to 2-12-16 12:00 Stability Class: D delta T/ delta z 61->10 m Delta T With Substitution Wind Sensor Height : 10 meter +++ Batch Release Times Only +++
Hours at Each Wind Direction and Speed Wind Wind Speed (miles/hour)
Direction , Mean .a 0.75- <4 4- <8 8- <13 13- <19 19- 24 >-24 Toral a Speeu 0 0 0 0 0 0 0 0.00 N 0.00 0 0 0 0 0 0 0 NNE 0 0 0 0 0 0 0 0.00 NE 0 0 0 0 0 0 0 0.00 ENE 0.00 0 0 0 0 0 0 0 E 0.00 0 0 0 0 0 0 0 ESE 0 0.00 0 0 0 0 0 0 SE 0 0.00 0 0 0 0 0 0 SSE 0 0.00 0 0 0 0 0 0 S 0 0 0 0 0 0 0 0.00 SSW 0 0 0 0 0 0 0 0.00 SW 0 0 1 0 0 0 1 6.48 WSW 0 0 0 0 0 0 0.00 W 0 0 0.00 0 0 0 0 0 0 WNW 0 0 0 0 0 0 0.00 NW 0 0 0 0 0 0 0 0.00 NNW 0 Total_________________0_______1______0______0_______0_.
0 1 0 0 0 0 Total Hours of Calm 0 Hours of Varying Wind Direction : 0 Hours of Missing Data : 0 Hours of Missing Data for All 0 Hours of No Stability Class : 0 Total hours of observation 4 TABLE 8 FOURTH QUARTER 2002 PAGE 4-0F 8
JOINT WIND FREQUENCY DISTRIBUTION BY STABILITY CLASS SITE: V. C. SUMMER Nuclear Station UNIT 1 Report Date : 03-02-27 Data Period : 2-12-16 09:00 to 2-12-16 12:00 Stability Class: E delta T/ delta z 61->10 m Delta T With Substitution Wind Sensor Height : 10 meter +++ Batch Release Times Only +++
Hours at Each Wind Direction and Speed Wind Wind Speed (miles/hour)
Direction Mean 0.75- <4 4- <8 8- <13 13- <19 19- 24 >24 Total' Speed N 0 0 0 0 0 0 0 0.00 NNE 0 0 0 0 0 0 0 0.00 NE 0 0 0 0 0 0 0 0.00 ENE 0 0 0 0 0 0 0 0.00 E 0 0 0 0 0 0 0 0.00 ESE 0 0 0 0 0 0 0 0.00 SE 0 0 0 0 0 0 0 0.00 SSE 0 0 0 0 0 0 0 0.00 S 0 0 0 0 0 0 0 0.00 SSW 0 0 0 0 0 0 0 0.00 SW 0 0 0 0 0 0 0 0.00 WSW 0 0 0 0 0 0 0 0.00 W 0 1 0 0 0 0 1 7.15 WNW 0 1 0 0 0 0 1 7.78 NW 0 0 0 0 0 0 0 0.00 NNW 0 0 0 0 0 0 0 0.00 Total 0 2 0 0 0 0 2 Hours of Calm : 0 Hours of Varying Wind Direction : 0 Hours of Missing Data : 0 Hours of Missing Data for All : 0 Hours of No Stability Class : 0 Total hours of observation 4 TABLE 8 FOURTH QUARTER 2002 PAGE 5 OF S
JOINT WIND FREQUENCY DISTRIBUTION BY STABILITY CLASS SITE: V. C. SUMMER Nuclear Station UNIT 1 Report Date : 03-02-27 Data Period : 2-12-16 09:00 to 2-12-16 12:00 Stability Class: F delta T/ delta z 61->10 m Delta T With Substitution Wind Sensor Height : 10 meter +++ Batch Release Times Only +++
Hours at Each Wind Direction and Speed Wind Wind Speed (miles/hour)
Direction Mean 0.75- <4 4- <8 8- <13 13- <19 19- 24 >24 Total' Speed N 0 0 0 0 0 0 0 0.00 NNE 0 0 0 0 0 0 0 0.00 NE 0 0 0 0 0 0 0 0.00 ENE 0 0 0 0 0 0 0 0.00 E 0 0 0 0 0 0 0 0.00 ESE 0 0 0 0 0 0 0 0.00 SE 0 0 0 0 0 0 0 0.00 SSE 0 0 0 0 0 0 0 0.00 S 0 0 0 0 0 0 0 0.00 SSW 0 0 0 0 0 0 0 0.00 SW 0 0 0 0 0 0 0 0.00 WSW 0 0 0 0 0 0 0 0.00 W 0 0 0 0 0 0 0 0.00 WNW 0 0 0 0 0 0 0 0.00 NW 0 0 0 0 0 0 0 0.00 NNW 0 0 0 0 0 0 0 0.00 Total 0 0 0 0 0 0 0 Hours of Calm : 0 Hours of Varying Wind Direction : 0 Hours of Missing Data : 0 Hours of Missing Data for All : 0 Hours of No Stability Class : 0 Total hours of observation : 4 TABLE 8 FOURTH QUARTER 2002 PAGE 6 OF 8
JOINT WIND FREQUENCY DISTRIBUTION BY STABILITY CLASS SITE: V. C. SUMMER Nuclear Station UNIT 1 Report Date : 03-02-27 Data Period : 2-12-16 09:00 to 2-12-16 12:00 Stability Class: G delta T/ delta z 61->10 m Delta T With Substitution Wind Sensor Height : 10 meter +++ Batch Release Times Only +++
Hours at Each Wind Direction and Speed Wind Wind Speed (miles/hour)
Direction Mean 0.75- <4 4- <8 8- <13 13- <19 19- 24 >24 Total' Speed N 0 0 0 0 0 0 0 0.00 NNE 0 0 0 0 0 0 0 0.00 NE 0 0 0 0 0 0 0 0.00 ENE 0 0 0 0 0 0 0 0.00 E 0 0 0 0 0 0 0 0.00 ESE 0 0 0 0 0 0 0 0.00 SE 0 0 0 0 0 0 0 0.00 SSE 0 0 0 0 0 0 0 0.00 S 0 0 0 0 0 0 0 0.00 SSW 0 0 0 0 0 0 0 0.00 SW 0 0 0 0 0 0 0 0.00 WSW 0 0 0 0 0 0 0 0.00 W 0 0 0 0 0 0 0 0.00 WNW 0 0 0 0 0 0 0 0.00 NW 0 0 0 0 0 0 0 0.00 NNW 0 0 0 0 0 0 0 0.00 Total 0 0 0 0 0 0 0 Hours of Calm : 0 Hours of Varying Wind Direction : 0 Hours of Missing Data : 0 Hours of Missing Data for All 0 Hours of No Stability Class : 0 Total hours of observation 4 TABLE 8 FOURTH QUARTER 2002 PAGE 7 OF 8
JOINT WIND FREQUENCY DISTRIBUTION BY STABILITY CLASS SITE: V. C. SUMMER Nuclear Station UNIT 1 Report Date : 03-02-27 Data Period : 2-12-16 09:00 to 2-12-16 12:00 Stability Class:ALL delta T/ delta z 61->10 m Delta T With Substitution Wind Sensor Height : 10 meter +++ Batch Release Times Only +++
Hours at Each Wind Direction and Speed Wind Wind Speed (miles/hour)
Direction Mean 0.75- <4 4- <8 8- <13 13- <19 19- 24 >24 Total' Speed N 0 0 0 0 0 0 0 0.00 NNE 0 0 0 0 0 0 0 0.00 NE 0 0 0 0 0 0 0 0.00 ENE 0 0 0 0 0 0 0 0.00 E 0 0 0 0 0 0 0 0.00 ESE 0 0 0 0 0 0 0 0.00 SE 0 0 0 0 0 0 0 0.00 SSE 0 0 0 0 0 0 0 0.00 S 0 0 0 0 0 0 0 0.00 SSW 0 0 0 0 0 0 0 0.00 SW 0 0 0 0 0 0 0 0.00 WSW 0 2 0 0 0 0 2 5.87 W 0 1 0 0 0 0 1 7.15 WNW 0 1 0 0 0 0 1 7.78 NW 0 0 0 0 0 0 0 0.00 NNW 0 0 0 0 0 0 0 0.00 Total 0 4 0 0 0 0 4 Hours of Calm . 0 Hours of Varying Wind Direction
- 0 Hours of Missing Data for All : 0 Hours of No Stability Class : 0 Total hours of observation : 4 TABLE 8 FOURTH QUARTER 2002 PAGE SOFS