ML22117A228
| ML22117A228 | |
| Person / Time | |
|---|---|
| Site: | Summer |
| Issue date: | 04/27/2022 |
| From: | Haselden R Dominion Energy South Carolina |
| To: | Document Control Desk, Office of Nuclear Reactor Regulation |
| References | |
| 22-136 | |
| Download: ML22117A228 (64) | |
Text
V.C. Summer Nuclear Station Bradham Blvd & Hwy 215, Jenkinsville, SC 29065 Mailing Address:
P.O. Box 88, Jenkinsvi lle, SC 29065 DominionEnergy.com ATTN: Document Control Desk U. S. Nuclear Regulatory Commission Washington, D. C. 20555-001 April 27, 2022 DOMINION ENERGY SOUTH CAROLINA, INC. (DESC)
VIRGIL C. SUMMER NUCLEAR STATION UNIT 1 DOCKET NO. 50-395 OPERATING LICENSE NO. NPF-12 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT
~
Dominion
~
Energy Serial No.22-136 LIC/TS/R0 Docket No. 50-395 License No. NPF-12 Enclosed is the DESC Annual Radioactive Effluent Release Report as required by 10 CFR 50.36a, Section 6.9.1.8 of the Virgil C. Summer Nuclear Station Technical Specifications, and Section 1.6.2.1 of the Offsite Dose Calculation Manual. This submittal covers the period of January 1 through December 31, 2021.
If there are any questions, please call Ms. Tracey Stewart at (803) 931-5663.
Sincerely, Robin R. Haselden Director, Nuclear Station Safety and Licensing V. C. Summer Nuclear Station Commitments contained in this letter: None
Enclosure:
Annual Radioactive Effluent Release Report Enclosure A: Meteorological Data Joint Frequency Distribution Tables cc:
w/o Enclosures unless noted G. J. Lindamood - Santee Cooper L. Dudes - NRC Region II G. Miller - NRC Project Manager NRC Resident Inspector (w/Enclosures)
ANI (w/Enclosures)
Anu Nair - SCDHEC-Bureau of Environmental Health Services (w/Enclosures)
~
Dominion pr Energy ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT VIRGIL C. SUMMER NUCLEAR STATION FOR THE OPERA TING PERIOD JANUARY 1, 2021 - DECEMBER 31, 2021 Health Physic
--~~?,
~
othyRiley, §uperintendent Health Physics Technical Services Todd Ellison, Manager Radiation Protection and Chemistry
Introduction ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT JANUARY - DECEMBER 2021 VIRGIL C. SUMMER NUCLEAR STATION This report is being submitted as a summary of quantities of radioactive liquid and gaseous effluents and solid waste released from the Virgil C. Summer Nuclear Station. This report is submitted in fulfillment of the requirements in the V. C. Summer Nuclear Station Operating License Technical Specifications Section 6.9.1.8, Offsite Dose Calculation Manual (ODCM) Section1.6.2 and 1 0CFR50.36(a) and follows the reporting details specified in USN RC Regulatory Guide 1.21 <1>.
Summary information of radioactive gaseous and liquid effluents is presented along with a summary of radioactive waste disposal as well as an evaluation of the radiological impact on man due to operation of the Virgil C. Summer Nuclear Station. Supplemental information including release limits also required by USNRC Regulatory Guide 1.21 is provided as Appendix A.
A.
Supplemental Information Regulatory limits for doses, dose rate and effluent concentration limits presented in Supplemental Information are from the Virgil C. Summer Nuclear Station ODCM and 40 CFR 190. Average energy ( E ) is not applicable to the method for determining release rate limits for fission and activation gaseous effluents, therefore, it has been omitted. A compilation of required supplemental information is provided in Appendix A.
B.
Gaseous Effluents Gaseous effluents released from ground level are summarized in Tables 1 and 2. An elevated release pathway does not exist at Virgil C. Summer Nuclear Station. Cumulative doses are discussed in Section E.
The error for both liquid and gaseous release totals is estimated as twenty percent for radioactive radionuclides sampled and released in effluent pathways. Error was derived using root sum of squares methodology considering known sources of error including calibration of detectors and flow measurement equipment, sample preparation, and analysis counting error.
C.
Liquid Effluents Liquid effluents are summarized in Tables 3 and 4. Estimated total errors are expressed as in Section B above.
ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT JANUARY - DECEMBER 2021 VIRGIL C. SUMMER NUCLEAR STATION D.
Solid Waste Shipments Solid waste shipments are summarized in Table 5. Curie content of radioactive waste packages is determined by dose rates and/or gamma spectroscopy analysis of samples.
The total error for each type of curie content determination is conservatively estimated to be the sum of a 15% systematic error and a 20% photon response error for the detector used.
E.
Radiological Impact on Man Dose to the maximum exposed individual in the unrestricted area was calculated using measured plant gaseous effluents and meteorological data in accordance with the Offsite Dose Calculation Manual. The source term involved O Waste Gas Decay Tank (WGDT) releases, 3.41 days of 6-inch Reactor Building purge releases, 12.55 days of 36-inch Reactor Building purge releases and a continuous 12-month Main Plant vent release.
Doses are summarized in Table 6. The total gaseous activities released are presented in Tables 1 and 2. The highest quarterly air doses at the station boundary resulting from the release of noble gases were 4.07E-04 mrad for gamma during the fourth quarter and 2.35E-04 mrad for beta during the fourth quarter. The maximum quarterly organ dose attributed to the releases, excluding Carbon-14, was 5.57E-04 mrem. Cumulative annual dose was 4.97E-04 mrad, 2.68E-04 mrad and 7.43E-04 mrem for gamma, beta, and organ dose, respectively. Discussion of the impact of Carbon-14 is included in Section K.
Measured plant liquid effluent data was used to calculate estimates of doses to individuals in accordance with the Offsite Dose Calculation Manual. The source term consisted of the isotopic contents of 224 Waste Monitor Tank batch releases, 38 Condensate Backwash Receiver Tank batch releases, 3 NaOH Sump batch releases, 7.49 days of Steam Generator Slowdown release and a continuous Turbine Building Sump release.
Doses are summarized in Table 6 and total liquid radioactivity released is described in Tables 3 and 4. The highest quarterly total body dose to the maximum exposed individual resulting from the release of radioactive liquid was 3.06E-03 mrem during the second quarter. The highest organ dose was 3.06E-03 mrem to the Liver for the second quarter.
Cumulative annual doses for the hypothetical maximum exposed individual were 7.89E-03 mrem for the total body and 7.91 E-3 mrem for the GI-LLI, the maximum annual organ.
The GI-LLI was the maximum exposed organ for the first, third and fourth quarter and the Liver was the maximum exposed organ for the second quarter.
Dose rates and concentrations were below station limits as specified in Supplemental Information,Section II A, B, and C during all the effluent releases.
ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT JANUARY - DECEMBER 2021 VIRGIL C. SUMMER NUCLEAR STATION Radiation exposure total dose to members of the public is limited by 40CFR 190 and 10CFR72.104 to less than 25 mrem to the total body and all organs except the thyroid which is limited to 75 mrem. This dose limit applies to effluents as well as Independent Spent Fuel Storage Installation (ISFSI). Radiation exposure within the site boundary was assessed through calculation of gamma and beta air dose at 0.25 miles of the gaseous effluent release point and direct measurement of exposure using thermoluminescent dosimeters. Onsite air dose for this reporting period was 1.62E-03 mrad gamma and
- 8. 73E-04 mrad beta, well below levels that can be distinguished above background. Quarterly thermoluminescent dosimetry (TLD) data from four onsite monitoring locations within 0.2 miles of the Reactor Building and eight locations at the site boundary were analyzed. Results from 2021 do not show a significant increase in dose rates above 2020 levels or historic operational average.
Radiation doses from radioactive effluents to workers at the Fairfield Hydro Station for this reporting period were calculated to be 2.35E-05 and 1.27E-05 mrad for gamma and beta, respectively.
Radiation doses from radioactive effluents to workers at the New Nuclear Site for this reporting period were calculated to be 2.02E-04 and 1.09E-04 mrad for gamma and beta, respectively.
The impact of Independent Spent Fuel Storage Installation (ISFSI) operation, located within the VCSNS Protected Area, which began cask storage on March 26, 2016, was assessed using six TLD locations monitoring the perimeter of the ISFSI site. The TLD locations were monitored for three quarters prior to fuel storage and continued to be monitored through 2021 during which fuel storage casks were stored. Analysis of monitoring results show a statistically significant increase in ISFSI perimeter dose as a result of fuel storage. The highest location shows an increase of 7.3 mrem/calendar quarter compared to pre-operation. Although the applicable limit for a member of the public applies to a real individual, a conservative analysis was used to demonstrate compliance with 40CFR 190 and 10CFR72.104 by assuming an individual is located at the perimeter of the ISFSI Protected Area for 2000 hours0.0231 days <br />0.556 hours <br />0.00331 weeks <br />7.61e-4 months <br /> per year. In this case, the hypothetical individual would have received 6.6 mrem.
Based on review of gaseous effluent dose calculations, analysis of onsite TLD monitoring including ISFSI perimeter monitoring, it can be concluded that total dose to any member of the public does not exceed the dose limits of 40CFR190 and 10CFR72.104.
Radiation doses from nearby uranium fuel cycle sources were not assessed. The ODCM, Sections 1.3.1 and B/1.3 establish a five (5) mile limit beyond which doses from nearby plants are insignificant. There are no uranium fuel cycle plants within a five (5) mile radius of Virgil C. Summer Nuclear Station.
ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT JANUARY - DECEMBER 2021 VIRGIL C. SUMMER NUCLEAR STATION F.
Abnormal Releases None G.
Meteorology The meteorological data for 2021 was collected and analyzed. An annual meteorological summary report of joint frequency distributions of wind direction and speed by atmospheric stability class for each quarter is included as Enclosure A.
The wind direction and wind speed data used were acquired from the 10-meter level of the primary monitoring tower. Stability was determined by the primary differential temperature (61 to 10 meter).
The combined annual data recovery for wind direction, wind speed and stability was
- 98. 70%. Primary variable recovery rates were as follows: wind direction (10 m) - 98.70%, wind speed (10 m) - 98.70%, and differential temperature (61 - 10 m) - 98.70%.
H.
Offsite Dose Calculation Manual The Virgil C. Summer Nuclear Station ODCM was not revised in 2021.
I.
Offsite Dose Calculation Manual Reportable Incidents The Turbine Building Sump Effluent Line Radiation Monitor RM-L8 required by ODCM Control 1.1.1.1 was out of service from February 2, 2021 at 1145 and presently remains out of service. The out of service condition was the result of spurious high rad alarms on the monitor. Significant troubleshooting efforts on the system was performed. The ratemeter, detector and pre-amp were replaced and tested, but the monitor would still spike. A replacement radiation monitor unit is currently in the procurement process. Compensatory actions are being implemented during this time period in accordance with the requirements of the ODCM.
The Condensate Backwash Receiver Tank Radiation Monitor RM-L 11 required by ODCM Control 1.1.1.1 was out of service from April 27, 2021 at 0915 to September 20, 2021 at 08:30. The out of service condition was the result of intermittent high rad alarms. The system was restored by replacing the old power supply with a newer style power supply. No effluent releases were made during the out of service period.
ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT JANUARY - DECEMBER 2021 VIRGIL C. SUMMER NUCLEAR STATION Steam Generator Slowdown Header Flow Transmitter IFI04705 was out of service from June 10, 2021 at 1244 to September 13, 2021 at 0824.The cam drive motor was replaced, and new fuses were installed to the integrator circuit. All indications were verified normal upon restoration. An alternate calibrated computer point was used to obtain flow data for Steam Generator effluent during this period.
J.
Major Changes to Radioactive Waste Treatment Systems During 2021, there were no major changes to the Radioactive Waste Treatment System.
K.
Carbon-14 Gaseous Effluents Carbon-14 production and release estimates were calculated using EPRI Report 1021106<2>, "Estimation of Carbon-14 in Nuclear Plant Gaseous Effluents". This calculation uses active core coolant mass, average neutron flux by energy and reactor coolant nitrogen concentrations to determine Carbon-14 generation based upon an effective full power year. The estimated generation for VC Summer Nuclear station for 2021 was 8.24 curies.
Public dose estimates were performed using Regulatory Guide 1.109 <3>
methodology. Carbon dioxide is assumed to make up 20% of the Carbon-14 gaseous emissions from the station based upon available references and on-site testing. Carbon-14 is the highest dose contributor of all radionuclides released in gaseous effluents. Annual dose resulting from Carbon-14 releases in gaseous effluents is estimated to be 1.46E-01 mrem total body and 7.32E-01 mrem to the maximum organ (bone).
L.
Errata/Correction to Previous ARERR Total lodine-131 reported in Table 1 for gaseous effluents in the annual report for 2020 included both lodine-131 and lodine-132 instead of only lodine-131. A corrected Table 1 is included as Enclosure B.
References ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT JANUARY - DECEMBER 2021 VIRGIL C. SUMMER NUCLEAR STATION
- 1. Regulatory Guide 1.21, "Measuring, Evaluating, and Reporting Radioactivity in Solid Wastes and Releases of Radioactive Materials in Liquid and Gaseous Effluents From Light Water Cooled Nuclear Power Plants", Revision 1,US Nuclear Regulatory Commission, Washington D.C., 1974.
Electric Power Research Institute, Palo Alto, CA, 2010.
- 3. Regulatory Guide 1.109, "Calculation of Annual Doses to Man from Routine Releases of
'Reactor effluents for the Purpose of Demonstrating compliance with 10 CFR50, Appendix I",
US Nuclear Regulatory Commission, Washington D.C., 1976.
APPENDIX A ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT JANUARY - DECEMBER 2021 VIRGIL C. SUMMER NUCLEAR STATION SUPPLEMENTAL INFORMATION I.
Regulatory Dose Limits:
A Fission and Activation Gases:
The air dose to an individual due to noble gases released in gaseous effluents shall be limited to less than or equal to 5 mrad for gamma radiation and 10 mrad for beta radiation during any calendar quarter and 10 mrad for gamma radiation and 20 mrad for beta radiation during any calendar year (ODCM, Section 1.2.3.1 ).
B. Iodines, Particulates (half-lives > 8 days) and Tritium:
The dose to an individual from radioiodine, tritium and radioactive materials in particulate form with half-lives greater than 8 days in gaseous effluents shall be limited to less than or equal to 7.5 mrem to any organ during any calendar quarter and 15 mrem to any organ during any calendar year (ODCM, Section 1.2.4.1 ).
C. Liquid Effluents:
The dose or dose commitment to an individual from radioactive materials in liquid effluents released shall be limited to less than or equal to 1.5 mrem to the total body and 5 mrem to any organ during any calendar quarter and 3 mrem to the total body and 10 mrem to any organ during any calendar year (ODCM, Section 1.1.3.1 ).
D. All Sources:
The annual dose equivalent shall not exceed 25 mrem to the whole body, 75 mrem to the thyroid and 25 mrem to any other organ (40 CFR 190).
II.
Dose Rate and Effluent Concentration Limits:
A. Fission and Activation Gases The dose rate in unrestricted areas due to radioactive materials released in gaseous effluents shall be limited to less than or equal to 500 mrem/year to the total body and less than or equal to 3000 mrem/yearto the skin (ODCM, Section 1.2.2.1).
APPENDIX A ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT JANUARY - DECEMBER 2021 VIRGIL C. SUMMER NUCLEAR STATION B. Iodines, Particulates (half-lives> 8 days) and Tritium:
The dose rate in unrestricted areas due to radioactive materials in effluents shall be limited to less than or equal to 1500 mrem/year to any organ (ODCM, Section 1.2.2.1 ).
C. Liquid Effluents:
The concentration of radioactive materials released from the site shall be limited to 10 times the concentrations specified in 10 CFR 20, Appendix B, Table 2, Column 2 for radionuclides other than dissolved or entrained noble gases. For dissolved or entrained noble gases, the concentration shall be limited to 2E-04 µCi/ml total activity (ODCM, Section 1.1.2.1).
Ill.
Average Energy:
Not Applicable IV.
Measurements and Approximations of Total Radioactivity:
A. Fission and activation gases: Gamma spectrometry (HPGe)
B. Iodines: Gamma spectrometry (HPGe)
C.
Particulates: Gamma spectrometry (HPGe), beta proportional counting, alpha proportional counting D. Tritium: Liquid scintillation E. Liquid effluents:
Gamma spectrometry (HPGe), liquid scintillation (H-3), beta proportional counting, alpha proportional counting.
APPENDIX A ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT JANUARY - DECEMBER 2021 VIRGIL C. SUMMER NUCLEAR STATION V.
Batch Releases:
A Gaseous:
- 1.
Number of batch releases: 0
- 2.
Total time period for batch releases: 0 min
- 3.
Maximum time period for a batch release: 0 min
- 4.
Average time period for a batch release: 0 min
- 5.
Minimum time period for a batch release: 0 min B.
Liquid:
- 1.
Number of batch releases:
37 For first quarter, 2021 41 For second quarter, 2021 73 For third quarter, 2021 114 For fourth quarter, 2021
- 2.
Total time period for batch releases:
2.81 E+03 min. for first quarter, 2021 3.08E+03 min. for second quarter, 2021 5.35E+03 min. for third quarter, 2021 7.53E+03 min. for fourth quarter 2021
- 3.
Maximum time period for a batch release:
8.30E+01 min. for second quarter, 2021 1.04E+02 min. for second quarter, 2021 8.50E+01 min. for third quarter, 2021 9.50E+01 min. for fourth quarter, 2021
APPENDIX A ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT JANUARY - DECEMBER 2021 VIRGIL C. SUMMER NUCLEAR STATION
- 4.
Average time period for batch releases:
7.58E+01 7.51E+01 7.33E+01 6.61E+01 min. for first quarter, 2021 min. for second quarter, 2021 min. for third quarter, 2021 min. for fourth quarter, 2021
- 5.
Minimum time period for a batch release:
7.00E+01 2.00E+00 1.20E+01 1.00E+00 min. for first quarter, 2021 min. for second quarter, 2021 min. for third quarter, 2021 min. for fourth quarter, 2021
- 6.
Average stream flow during periods of release of effluent into a flowing stream:
4.16E+06 4.80E+06 5.96E+06 5.39E+06 gpm for first quarter, 2021 gpm for second quarter, 2021 gpm for third quarter, 2021 gpm for fourth quarter, 2021 VI.
Abnormal Releases:
A Gaseous:
- 1.
Number of releases: 0
- 2.
Total activity released: 0 B.
Liquid:
- 1.
Number of releases: 0
- 2.
Total activity released: 0
ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT JANUARY - DECEMBER 2021 Virgil C. Summer Nuclear Station TABLE 1 Gaseous Effluents-Summation of All Releases Type of Effluent Units Qtr 1 Qtr2 Qtr3 Qtr4 A. Fission & Activation Gases
- 1. Total Release Curies 5.56E-02 6.24E-04 0.00E+00 4.22E-01
- 2. Average Release Rate for Period
µCi/sec 7.15E-03 7.94E-05 0.00E+00 5.31E-02
- 3. Percent of Applicable Limit 1.78E-03 1.81E-05 0.00E+00 8.14E-03 B. Iodines
- 1. Total lodine-131 Curies 0.00E+00 0.00E+00 0.00E+00 0.00E-00
- 2. Average Release Rate for Period
µCi/sec 0.00E+00 0.00E+00 0.00E+00 0.00E-00
- 3. Percent of Applicable Limit 0.00E+00 0.00E+00 0.00E+00 0.00E-00 C. Particulates
- 1. Total Particulates (Half-lives> 8 days)
Curies 1.04E-05 0.00E+00 0.00E+00 0.00E+00
- 2. Average Release Rate for Period
µCi/sec 1.34E-06 0.00E+00 0.00E+00 0.00E+00
- 3. Percent of Applicable Limit 0.00E+00 0.00E+00 0.00E+00 0.00E+00
- 4. Gross Alpha Activity Curies 0.00E+00 0.00E+00 0.00E+00 0.00E+00 D. Tritium
- 1. Total Release Curies 3.24E-01 2.09E-03 0.00E+00 9.77E-01
- 2. Average Release Rate for Period
µCi/sec 4.17E-02 2.66E-04 0.00E+00 1.23E-01
- 3. Percent of Applicable Limit 2.46E-03 1.59E-05 0.00E+00 7.42E-03 E. Carbon-14
- 1. Total Release Curies 2.03E+00 2.05E+00 2.0BE+00 2.0BE+00
- 2. Average Release Rate for Period
µCi/sec 2.61E-01 2.61E-01 2.61E-01 2.61E-01 Error,%
2.00E+01 2.50E+01 2.50E+01 00E+00 2.00E+01 N/A
Nuclides Released ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT JANUARY - DECEMBER 2021 Virgil C. Summer Nuclear Station TABLE2 Gaseous Effluents-Ground Level Releases Continuous Mode Batch Mode Units Qtr 1 Qtr2 Qtr3 Qtr4 Qtr 1 Qtr2 Qtr3
- 1. Fission and Activation Gases Ar-41 Curies 4.72E-02 4.79E-04 0.00E+00 1.66E-01 0.00E+00 0.00E+00 0.00E+00 Xe-133 Curies 6.56E-03 1.23E-04 0.00E+00 8.30E-09 0.00E+00 0.00E+00 0.00E+00 Xe-135 Curies 1.85E-03 2.24E-05 0.00E+00 2.56E-01 0.00E+00 0.00E+00 0.00E+00 Total for Period Curies 5.56E-02 6.24E-04 0.00E+00 4.22E-01 0.00E+00 0.00E+00 0.00E+00
- 2. Iodines 1-132 Curies 0.00E+00 0.00E+00 0.00E+00 1.38E-06 0.00E+00 0.00E+00 0.00E+00 Total for Period Curies 0.00E+00 0.00E+00 0.00E+O0 1.38E-06 0.00E+00 0.00E+00 0.00E+00
- 3. Particulates As-76 Curies 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Be-7 Curies 1.04E-05 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Br-82 Curies 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Total for Period Curies 1.04E-05 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00
- 4. Tritium H-3 Curies 3.24E-01 2.09E-03 0.00E+00 9.77E-01 0.00E+00 0.00E+00 0.00E+00 Qtr4 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00
ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT JANUARY - DECEMBER 2021 Virgil C. Summer Nuclear Station TABLE3 Liquid Effluents-Summation of All Releases Type of Effluent A. Fission & Activation Products
- 1.
Total Release (not including Tritium, Gases, and Alpha)
- 2.
Average Diluted Concentration During Period
- 3.
Percent of Applicable Limit B. Tritium
- 1.
Total Release
- 2.
Average Diluted Concentration During Period
- 3.
Percent of Applicable Limit C. Dissolved and Entrained Gases
- 1.
Total Release
- 2.
Average Diluted Concentration During Period
- 3.
Percent of Applicable Limit D. Gross Al[!ha Radioactivirt
- 1.
Total Release E. Waste Volume Released (Pre-Dilution)
F. Volume of Dilution Water Used Units Curies
µCi/ml Curies
µCi/ml Curies
µCi/ses Curies Liters Liters Qtr 1 Qtr2 Qtr3 Qtr4 4.87E-05 3.40E-04 1.06E-03 3.94E-04 1.03E-12 5.61E-12 8.09E-12 3.02E-12 9.73E-04 6.81E-03 2.11E-02 7.SSE-03 2.40E+02 3.03E+02 2.06E+02 5.15E+01 5.07E-06 5.00E-06 1.58E-06 3.94E-07 5.07E-01 5.00E-01 1.58E-01 3.94E-02 6.SSE-07 2.29E-03 5.01E-04 2.79E-04 1.45E-14 3.78E-11 3.84E-12 2.14E-12 7.27E-09 1.89E-05 1.92E-06 1.07E-06 0.00E+00 0.00E+00 0.00E+00 0.00E+00 1.01E+07 1.15E+07 1.10E+07 7.06E+07 4.73E+10 6.07E+10 1.31E+11 1.30E+11 Error,%
2.00E+01 2.00E+01 2.00E+01 0.00E+00 3.00E+00 4.30E+00
Nuclides Released Ar-41 Co-58 Co-60 Cr-51 Cs-137 H-3 Kr-85M Kr-88 Mn-54 Nb-95 Ni-63 Sb-125 Te-123M Xe-133 Xe-133m Xe-135 Zr-95 Total for Period ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT JANUARY - DECEMBER 2021 Virgil C. Summer Nuclear Station TABLE4 Liquid Effluents Continuous Mode Batch Mode Units Qtr 1 Qtr2 Qtr3 Qtr4 Qtr 1 Qtr2 Qtr3 Curies 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 1.S0E-04 2.0SE-06 Curies 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Curies 0.00E+00 0.00E+00 0.00E+00 0.00E+00 4.81E-05 3.34E-05 2.90E-04 Curies 0.00E+00 0.00E+00 0.00E+00 O.00E+00 0.00E+00 0.00E+00 0.00E+00 Curies 0.00E+00 0.00E+00 0.00E+00 0.00E+00 5.36E-07 4.28E-08 0.00E+00 Curies 4.45E-03 0.00E+00 0.00E+00 0.00E+00 2.40E+02 3.03E+02 2.06E+02 Curies 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 6.15E-06 0.00E+00 Curies 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 4.88E-06 0.00E+00 Curies 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 1.55E-05 Curies 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Curies 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 2.68E-04 7.40E-04 Curies 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 3.86E-05 1.04E-05 Curies 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Curies 0.00E+00 0.00E+00 0.00E+00 0.00E+00 6.88E-07 1.91E-03 4.32E-04 Curies 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 2.59E-05 0.00E+00 Curies 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 1.69E-04 6.74E-05 Curies 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Curies 4.45E-03 0.00E+00 0.00E+00 0.00E+O0 2.40E+02 3.03E+02 2.06E+02 Qtr4 1.88E-06 9.73E-05 2.50E-04 7.31E-06 2.67E-08 5.15E+01 0.00E+00 0.00E+00 1.16E-05 1.17E-05 0.00E+00 5.96E-06 7.00E-06 2.71E-04 0.00E+00 6.26E-06 2.83E-06 5.15E+01
ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT January - December 2021 Virgil C. Summer Nuclear Station Dominion Energy Table 5 SOLID WASTE SHIPMENTS
- 1. Solid Waste Shipped Offsite for Burial or Disposal (Not irradiated fuel) 2021 Tvpe of Waste Unit Total
- a. Spent resins, filters, sludge, m3 2.98E+01 evaporator bottoms, etc.
Ci 1.79E+02
- b. Dry compressible waste, metals, m3 2.93E+02 contaminated equipment, etc.
Ci 6.95E-02
- c. Irradiated components, m3 0.00E+00 control rods, etc.
Ci 0.00E+00
- d. Other waste, oil, etc.
m3 3.80E-02 Ci 6.77E-05 Est. Total Error,%
2.5E+01 2.5E+01 NIA 2.5E+01
- 2. Estimate of major nuclide composition for the year (by type of waste) for concentrations above 1.0%
- a.
Ni-63 81.64 %
1.46E+02 Ci Co-60 9.08%
1.62E+01 Ci Fe-55 4.81%
8.61E+00 Ci Mn-54 1.85%
3.23E+00 Ci
- b.
Co-60 32.14 %
2.23E-02 Ci Fe-55 27.02%
1.88E-02 Ci Ni-63 10.09%
7.01E-03 Ci Co-58 8.17%
5.68E-03 Ci Nb-95 7.24%
5.03E-03 Ci Cr-51 5.11%
3.55E-03 Ci Zr-95 3.85 %
2.67E-03 Ci Mn-54 2.67%
1.85E-03 Ci Sb-125 1.42%
9.89E-04 Ci
C.
ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT January - December 2021 Virgil C. Summer Nuclear Station Dominion Energy Table 5 SOLID WASTE SHIPMENTS
'I ---------=-N-=--o_n_e--------,---N=-=-/-:-::A----,-----N-/A---~
- d.
Am-241 (Smoke Detectors) 100%
6.77E-05 Ci
- 3. Solid Waste Disposition Number of Shioments Mode of Transnortation Destination Energy Solutions, LLC -
2 Hittman Transport Barnwell Processing Facility Barnwell, SC Landstar/Miller Alaron Nuclear Services 7
Transfer/FedEx Wampum, PA Specialty Transport, Inc.
UniTech Services Group, Inc.
2 Oakridge, TN Notes:
- 1.
Two shipments by Hittman Transport containing (1)10-160 FR SEDS High Integrity Container of Dewatered Primary Resin; (1) 8-120 FR High Integrity Container were shipped to the Barnwell Processing facility for processing.
- 2.
Four shipments by Landstar, one Shipment by Miller Transfer, and two shipments by FedEx containing (6) 20-foot Sealands of Dry Active Waste; (11) 8-25 Boxes of Gross Dewatered Resin and DAW, and (2) drums of smoke detectors were shipped to Alaron in Wampum, PA for processing/waste disposal.
- 3.
Two shipments by Specialty Transport, Inc. containing (3) 20-foot Sealands of Green-is-Clean (GIG) waste was shipped to Oakridge, TN for processing.
ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT JANUARY - DECEMBER 2021 Virgil C. Summer Nuclear Station TABLE6 Gaseous Effluents Parameter Location Dose Dose Limit
% of Limit Qtr 1 Gamma Air Dose (mrad) 1.61 km ENE 8.89E-05 5.00E+00 0.00 Beta Air Dose (mrad) 1.61 km ENE 3.32E-05 1.00E+01 0.00 Total Body Dose (mrem) 1.61 km ENE 8.44E-05 5.00E+00 0.00 Skin Dose (mrem) 1.61 km ENE 1.24E-04 7.50E+00 0.00 Max Organ Dose (mrem) 1.77 km E 1.85E-04 7.50E+00 0.00 Child-Liver Qtr 2 Gamma Air Dose (mrad) 1.61 km ENE 9.07E-07 5.00E+00 0.00 Beta Air Dose (mrad) 1.61 km ENE 3.51E-07 1.00E+01 0.00 Total Body Dose (mrem) 1.61 km ENE 8.61E-07 5.00E+00 0.00 Skin Dose (mrem) 1.61 km ENE 1.27E-06 7.50E+00 0.00 Max Organ Dose (mrem) 1.77 km E 1.19E-06 7.50E+00 0.00 Child - Liver Qtr3 Gamma Air Dose (mrad) 1.61 km ENE 0.00E+00 5.00E+00 0.00 Beta Air Dose (mrad) 1.61 km ENE 0.00E+00 1.00E+01 0.00 Total Body Dose (mrem) 1.61 km ENE 0.00E+00 5.00E+00 0.00 Skin Dose (mrem) 1.61 km ENE 0.00E+00 7.50E+00 0.00 Max Organ Dose (mrem) 1.77 km E 0.00E+00 7.50E+00 0.00 None-None Qtr4 Gamma Air Dose (mrad) 1.61 km ENE 4.07E-04 5.00E+00 0.01 Beta Air Dose (mrad) 1.61 km ENE 2.35E-04 1.00E+01 0.00 Total Body Dose (mrem) 1.61 km ENE 3.86E-04 5.00E+00 0.01 Skin Dose (mrem) 1.61 km ENE 6.32E-04 7.50E+00 0.01 Max Organ Dose (mrem) 1.77 km E 5.57E-04 7.50E+00 0.01 Child - Thyroid Year Gamma Air Dose (mrad) 1.61 km ENE 4.97E-04 1.00E+01 0.00 Beta Air Dose (mrad) 1.61 km ENE 2.68E-04 2.00E+01 0.00 Total Body Dose (mrem) 1.61 km ENE 4.71E-04 1.00E+01 0.00 Skin Dose (mrem) 1.61 km ENE 7.57E-04 1.50E+01 0.01 Max Organ Dose (mrem)*
1.77 km E 7.43E-04 1.50E+01 0.00 Child - Thyroid
(* Includes dose from all nuclides excluding Carbon-14. See Section K for C-14)
Liquid Effluents Parameter Max Rece~tor Dose Dose Limit
% of Limit Qtr 1 Max Organ Dose (mrem)
Adult - Gi-Lli 2.63E-03 5.00E+00 0.05 Total Body Dose (mrem)
Adult - Total Body 2.63E-03 1.50E+00 0.18 Qtr2 Max Organ Dose (mrem)
Adult - Liver 3.06E-03 5.00E+00 0.06 Total Body Dose (mrem)
Adult - Total Body 3.06E-03 1.50E+00 0.20 Qtr3 Max Organ Dose (mrem)
Adult - Gi-Lli 1.75E-03 5.00E+00 0.03 Total Body Dose (mrem)
Adult - Total Body 1.75E-03 1.50E+00 0.12 Qtr4 Max Organ Dose (mrem)
Adult - Gi-Lli 4.76E-04 5.00E+00 0.01 Total Body Dose (mrem)
Adult - Total Body 4.57E-04 1.50E+00 0.03 Year Max Organ Dose (mrem)
Adult - Gi-Lli 7.91E-03 1.00E+01 0.08 Total Body Dose (mrem)
Adult - Total Body 7.89E-03 3.00E+00 0.26 NOTE: See Section E for max organ for each quarter
ENCLOSURE A ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT JANUARY - DECEMBER 2021 VIRGIL C. SUMMER NUCLEAR STATION METEOROLOGICAL DATA JOINT FREQUENCY DISTRIBUTION TABLES Quarterly Summaries Annual Summary
Quarterly Summaries
Site:
VC Period of Record =
Elevation:
Stability Class:
Wind Direction N
NNE NE ENE E
WNW NW NNW Total Speed:
SPl0Tl A
0.8-3.9 7
2 0
0 0
0 0
0 1
0 3
7 6
7 6
5 44 Calm Hours not Included above for:
Variable Direction Hours for:
Invalid Hours for:
Number of Valid Hours for this Table:
Total Hours for the Period:
Page 1 of 8 Joint Frequency Distribution Hours at Each Wind Speed and Direction Total Period 01/01/2021 01:00 - 04/01/2021 00:00 Direction:
DRlOTl Lapse:
DT61Tl Delta Temperature 4.0-7.9 8.0-12.9 9
4 0
5 1
2 3
1 0
0 0
0 0
7 0
20 7
26 4
25 9
14 0
14 7
8 5
137 39 Total Period Total Period Total Period Total Period Extremely Unstable Wind Speed (mph) 13.0-18.9 2
4 10 0
0 0
0 1
0 0
0 0
21 19.0-23.9 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
All Hours All Hours All Hours All Hours
>24.0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
Report Printed On: 03/21/2022 14:27 All Hours Total 19 10 16 4
5 0
0 1
4 8
31 37 40 21 27 19 242 0
0 242 2160
Site:
VC Period of Record =
Elevation:
Stability Class:
Wind Direction N
NNE NE ENE E
WNW NW NNW Total Speed:
B SP10Tl 0.8-3.9 5
3 2
0 0
0 0
0 0
0 3
2 19 Calm Hours not Included above for:
Variable Direction Hours for:
Invalid Hours for:
Number of Valid Hours for this Table:
Total Hours for the Period:
Page 2 of8 Joint Frequency Distribution Hours at Each Wind Speed and Direction Total Period 01/01/2021 01:00 - 04/01/2021 00:00 Direction:
DRl0TI Lapse:
DT61TJ Delta Temperature Moderately Unstable Wind Speed (mph) 4.0-7.9 8.0-12.9 13.0-18.9 19.0-23.9
>24.0 9
7 6
0 0
6 20 25 2
0 5
20 23 0
0 4
2 0
0 0
4 3
0 0
0 2
0 0
0 0
0 0
0 0
2 0
0 0
3 6
0 0
3 2
0 3
3 0
0 0
4 0
0 0
0 4
0 0
0 0
0 0
0 0
3 2
0 0
0 3
4 0
0 56 70 57 4
0 Total Period All Hours Total Period AU Hours Total Period All Hours Total Period All Hours Report Printed On: 03/21/2022 14:27 All Hours Total 27 56 50 6
8 2
3 10 8
7 5
4 1
8 10 206 0
0 206 2160
Site:
VC Report Printed On: 03/21/2022 14:27 Joint Frequency Distribution Hours at Each Wind Speed and Direction Total Period All Hours Period of Record =
01/01/2021 01 :00 - 04/01/2021 00:00 Elevation:
Speed:
SPIOTI Direction:
DRIOTI Lapse:
DT61Tl Stability Class:
C Delta Temperature Slightly Unstable Wind Speed (mph)
Wind Direction 0.8-3.9 4.0-7.9 8.0-12.9 13.0-18.9 19.0-23.9
>24.0 Total N
3 12 14 2
0 0
31 NNE 7
53 23 0
0 84 NE 11 59 18 2
0 91 ENE 0
11 30 8
0 0
49 E
0 3
16 0
0 0
19 ESE 0
3 3
0 0
0 6
SE 8
0 0
0 0
9 SSE 9
I 0
0 0
11 s
13 3
0 0
0 17 SSW 3
9 4
0 0
0 16 SW 0
4 0
0 0
5 WSW 8
0 0
0 0
9 w
2 3
1 0
0 0
6 WNW 2
2 0
0 0
0 4
NW 3
5 2
0 0
0 10 NNW 11 3
2 0
0 17 Total 20 119 190 53 2
0 384 Calm Hours not Included above for:
Total Period All Hours Variable Direction Hours for:
Total Period All Hours 0
Invalid Hours for:
Total Period All Hours 0
Number of Valid Hours for this Table:
Total Period All Hours 384 Total Hours for the Period:
2160 Page 3 of 8
Site:
VC Report Printed On: 03/21/2022 14:27 Joint Frequency Distribution Hours at Each Wind Speed and Direction Total Period All Hours Period of Record =
01/01/2021 01:00 - 04/01/2021 00:00 Elevation:
Speed:
SPIOTl Direction:
DRIOTl Lapse:
DT61Tl Stability Class:
D Delta Temperature Neutral Wind Speed (mph)
Wind Direction 0.8-3.9 4.0-7.9 8.0-12.9 13.0-18.9 19.0-23.9
>24.0 Total N
5 11 11 2
0 0
29 NNE 11 12 10 7
0 0
40 NE 3
23 34 7
0 0
67 ENE 3
36 27 4
0 0
70 E
1 46 17 0
0 0
64 ESE 4
18 3
0 0
0 25 SE 5
27 7
0 0
0 39 SSE 9
22 2
0 0
0 33 s
7 14 4
0 0
0 25 SSW 11 12 16 0
0 0
39 SW 17 30 3
0 0
0 50 WSW 10 26 2
0 0
0 38 w
21 24 0
0 0
46 WNW 12 18 0
0 0
31 NW 12 16 10 l
0 0
39 NNW 3
6 13 4
0 0
26 Total 134 341 161 25 0
0 661 Calm Hours not Included above for:
Total Period All Hours Variable Direction Hours for:
Total Period All Hours 0
Invalid Hours for:
Total Period All Hours 0
Number of Valid Hours for this Table:
Total Period All Hours 661 Total Hours for the Period:
2160 Page 4 of 8
Site:
VC Report Printed On: 03/21/2022 14:27 Joint Frequency Distribution Hours at Each Wind Speed and Direction Total Period All Hours Period of Record =
01/01/2021 01:00 - 04/01/2021 00:00 Elevation:
Speed:
SPIOTl Direction:
DRIOTl Lapse:
DT61Tl Stability Class:
E Delta Temperature Slightly Stable Wind Speed (mph)
Wind Direction 0.8-3.9 4.0-7.9 8.0-12.9 13.0-18.9 19.0-23.9
>24.0 Total N
6 9
4 0
0 0
19 NNE 7
14 3
0 0
0 24 NE 2
8 2
0 0
0 12 ENE 3
5 0
0 0
0 8
E 3
6 I
0 0
0 10 ESE 7
4 0
0 0
0 11 SE 7
5 0
0 0
0 12 SSE 9
18 0
0 0
28 s
8 9
0 0
0 18 SSW 17 35 3
0 0
0 55 SW 35 23 0
0 0
59 WSW 33 16 0
0 0
0 49 w
21 13 0
0 0
35 WNW 14 8
0 0
0 0
22 NW 9
13 0
0 0
0 22 NNW 8
11 4
0 0
0 23 Total 189 197 21 0
0 0
407 Calm Hours not Included above for:
Total Period All Hours Variable Direction Hours for:
Total Period AllHonrs 0
Invalid Hours for:
Total Period All Hours 0
Number of Valid Hours for this Table:
Total Period All Hours 407 Total Hours for the Period:
2160 Page 5 of 8
Site:
VC Report Printed On: 03/21/2022 14:27 Joint Frequency Distribution Hours at Each Wind Speed and Direction Total Period All Hours Period of Record =
01/01/2021 01:00 - 04/01/2021 00:00 Elevation:
Speed:
SPlOTl Direction:
DRlOTI Lapse:
DT61TI Stability Class:
F Delta Temperature Moderately Stable Wind Speed (mph)
Wind Direction 0.8-3.9 4.0-7.9 8.0-12.9 13.0-18.9 19.0-23.9
>24.0 Total N
6 2
0 0
0 0
8 NNE 3
0 0
0 0
0 3
NE 0
0 0
0 0
ENE 0
0 0
0 0
E 2
0 0
0 0
0 2
ESE 4
0 0
0 0
0 4
SE 4
11 0
0 0
0 15 SSE 11 9
0 0
0 0
20 s
6 13 0
0 0
0 19 SSW 13 9
0 0
0 0
22 SW 14 7
0 0
0 0
21 WSW 8
6 0
0 0
0 14 w
6 4
0 0
0 0
10 WNW 11 0
0 0
0 12 NW 13 6
0 0
0 0
19 NNW 2
0 0
0 0
0 2
Total 105 68 0
0 0
0 173 Calm Hours not Included above for:
Total Period All Hours Variable Direction Hours for:
Total Period All Hours 0
Invalid Hours for:
Total Period All Hours 0
Number of Valid Hours for this Table:
Total Period All Hours 173 Total Hours for the Period:
2160 Page 6 of 8
Site:
VC Report Printed On: 03/21/2022 14:27 Joint Frequency Distribution Hours at Each Wind Speed and Direction Total Period All Hours Period of Record =
01/01/2021 01:00 - 04/01/2021 00:00 Elevation:
Speed:
SPIOTl Direction:
DRIOTl Lapse:
DT61Tl Stability Class:
G Delta Temperature Extremely Stable Wind Speed (mph)
Wind Direction 0.8-3.9 4.0-7.9 8.0-12.9 13.0-18.9 19.0-23.9
>24.0 Total N
0 0
0 0
0 NNE 2
0 0
0 0
0 2
NE 1
0 0
0 0
0 1
ENE 0
0 0
0 0
0 0
E 0
0 0
0 0
0 0
ESE 0
0 0
0 0
0 0
SE 1
0 0
0 0
0 SSE 4
0 0
0 0
5 s
5 4
0 0
0 0
9 SSW 6
2 0
0 0
0 8
SW 11 4
0 0
0 0
15 WSW 18 1
0 0
0 0
19 w
7 0
0 0
0 0
7 WNW 7
0 0
0 0
0 7
NW 7
2 0
0 0
0 9
NNW 2
0 0
0 0
0 2
Total 71 15 0
0 0
0 86 Calm Hours not Included above for:
Total Period All Hours Variable Direction Hours for:
Total Period All Hours 0
Invalid Hours for:
Total Period All Hours 0
Number of Valid Hours for this Table:
Total Period All Hours 86 Total Hours for the Period:
2160 Page 7 of 8
Site:
VC Period of Record =
Elevation:
Speed:
SP10Tl Stability Class:
ALL Wind Direction 0.8-3.9 N
32 NNE 29 NE 10 ENE 7
E 7
63 WNW 53 NW 53 NNW 23 Total 582 Calm Hours not Included above for:
Variable Direction Hours for:
Invalid Hours for:
Number of Valid Hours for this Table:
Total Hours for the Period:
Page 8 of8 Joint Frequency Distribution Hours at Each Wind Speed and Direction Total Period 01/01/2021 01:00 - 04/01/2021 00:00 Direction:
DRl0Tl Lapse:
DT61Tl Delta Temperature Wind Speed (mph) 4.0-7.9 8.0-12.9 13.0-18.9 19.0-23.9
>24.0 53 37 12 0
0 43 86 59 2
0 52 116 58 2
0 57 61 13 0
0 62 38 0
0 27 6
0 0
0 52 7
0 0
0 60 7
0 0
0 57 15 2
0 0
77 24 3
0 91 15 1
0 0
87 6
0 0
0 73 12 0
0 0
44 0
0 0
59 21 0
0 39 29 8
0 0
933 481 156 7
0 Total Period All Hours Total Period All Hours Total Period All Hours Total Period All Hours Report Printed On: 03/21/2022 14:27 All Hours Total 134 219 238 138 108 48 77 101 102 156 188 171 148 98 134 99 2159 0
0 2159 2160
Site:
VC Period of Record =
Elevation:
Speed:
SPIOTI Stability Class:
A Wind Direction 0.8-3.9 N
17 NNE 16 NE 8
ENE 0
E 0
ESE 0
SE 0
SSE 0
s SSW 0
SW 4
WSW 8
w 12 WNW 5
NW 3
NNW 7
Total 81 Calm Hours not Included above for:
Variable Direction Hours for:
Invalid Hours for:
Number of Valid Hours for this Table:
Total Hours for the Period:
Page 1 of 8 Joint Frequency Distribution Hours at Each Wind Speed and Direction Total Period 04/01/2021 01:00 - 07/01/2021 00:00 Direction:
DRIOTI Lapse:
DT61Tl Delta Temperature Extremely Unstable Wind Speed (mph) 4.0-7.9 8.0-12.9 13.0-18.9 19.0-23.9
>24.0 28 12 6
2 32 10 2
0 0
32 27 3
0 0
20 18 2
0 0
6 10 0
0 0
3 2
0 0
0 0
0 0
0 2
3 0
0 0
5 0
0 0
11 13 0
0 0
46 14 0
0 0
51 12 0
0 0
24 10 0
0 0
14 0
0 0
0 6
13 1
0 0
16 4
6 1
0 293 153 20 3
Total Period All Hours Total Period All Hours Total Period All Hours Total Period All Hours Report Printed On: 03/21/2022 14:28 All Hours Total 66 60 70 40 16 5
5 7
24 64 71 46 19 23 34 551 0
0 113 551 2184
Site:
VC Period of Record =
Elevation:
Stability Class:
Wind Direction N
NNE NE ENE E
WNW NW NNW Total Speed:
SPlOTI B
0.8-3.9 5
2 2
1 1
0 1
0 2
0 2
4 2
4 4
3 33 Calm Hours not Included above for:
Variable Direction Hours for:
Invalid Hours for:
Number of Valid Hours for this Table:
Total Hours for the Period:
Page 2 of 8 Joint Frequency Distribution Hours at Each Wind Speed and Direction Total Period 04/01/2021 01:00 - 07/01/2021 00:00 Direction:
DRIOTI Lapse:
DT61Tl Delta Temperature 4.0-7.9 8.0-12.9 4
4 2
9 3
9 3
2 3
2 1
3 4
3 4
9 5
23 2
11 3
6 0
2 3
0 5
4 82 51 Total Period Total Period Total Period Total Period Moderately Unstable Wind Speed (mph) 13.0-18.9 19.0-23.9 6
0 6
0 5
4 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 3
22 5
All Hours All Hours All Hours All Hours
>24.0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
Report Printed On: 03/21/2022 14:28 All Hours Total 19 19 23 6
6 3
3 7
9 15 27 18 8
7 7
16 193 0
0 113 193 2184
Site:
VC Period of Record =
Elevation:
Speed:
SPl0Tl Stability Class:
C Wind Direction 0.8-3.9 N
3 NNE 2
NE 0
ENE E
ESE 0
s 0
WSW 2
w 0
WNW 3
NW 2
NNW 2
Total 24 Calm Hours not Included above for:
Variable Direction Hours for:
Invalid Hours for:
Number of Valid Hours for this Table:
Total Hours for the Period:
Page 3 of 8 Joint Frequency Distribution Hours at Each Wind Speed and Direction Total Period 04/01/2021 01:00 - 07/01/2021 00:00 Direction:
DRlOTl Lapse:
DT61Tl Delta Temperature 4.0-7.9 3
3 6
3 2
4 4
7 4
8 6
8.0-12.9 11 8
0 71 Total Period Total Period Total Period Total Period 9
9 14 4
8 2
3 2
12 5
0 0
72 Slightly Unstable Wind Speed (mph) 13.0-18.9 4
1 2
2 0
0 0
0 0
0 0
0 0
2 13 19.0-23.9
>24.0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 All Hours All Hours All Hours All Hours Report Printed On: 03/21/2022 14:28 All Hours Total 19 15 22 10 11 6
8 11 16 15 12 14 8
3 4
6 180 0
0 113 180 2184
Site:
VC Period of Record =
Elevation:
Stability Class:
Wind Direction N
NNE NE ENE E
WNW NW NNW Total Speed:
SPIOTI D
0.8-3.9 1
4 6
2 1
9 8
13 22 18 13 9
4 4
116 Calm Hours not Included above for:
Variable Direction Hours for:
Invalid Hours for:
Number of Valid Honrs for this Table:
Total Hours for the Period:
Page4 of 8 Joint Frequency Distribution Hours at Each Wind Speed and Direction Total Period 04/01/2021 01:00 - 07/01/2021 00:00 Direction:
DRIOTI Lapse:
DT61Tl Delta Temperature 4.0-7.9 5
4 6
8.0-12.9 14 25 5
22 10 19 36 39 35 13 3
10 3
249 Total Period Total Period Total Period Total Period 8
9 15 14 12 4
2 6
14 5
3 0
2 2
0 97 Neutral Wind Speed (mph) 13.0-18.9 19.0-23.9
>24.0 0
0 0
0 0
0 2
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
3 2
0 All Hours All Hours All Hours All Hours Report Printed On: 03/21/2022 14:28 All Hours Total 15 17 24 35 39 7
27 21 34 63 66 56 26 14 16 7
467 0
0 113 467 2184
Site; VC Report Printed On; 03/21/2022 14:28 Joint Frequency Distribution Hours at Each Wind Speed and Direction Total Period All Hours Period of Record =
04/01/2021 01:00 - 07/01/2021 00:00 Elevation:
Speed; SPlOTl Direction:
DRlOTI Lapse:
DT61Tl Stability Class:
E Delta Temperature Slightly Stable Wind Speed (mph)
Wind Direction 0.8-3.9 4.0-7.9 8.0-12.9 13.0-18.9 19.0-23.9
>24.0 Total N
4 4
1 0
0 0
9 NNE 3
2 3
0 0
0 8
NE 5
5 2
0 0
0 12 ENE 2
11 2
0 0
0 15 E
4 15 0
0 0
20 ESE 0
9 0
0 0
0 9
SE 7
23 0
0 0
0 30 SSE 15 23 0
0 0
0 38 s
19 13 1
0 0
0 33 SSW 18 34 3
0 0
0 55 SW 24 13 0
0 0
0 37 WSW 23 7
0 0
0 0
30 w
14 7
0 0
0 0
21 WNW 15 2
0 0
0 0
17 NW 7
7 1
0 0
0 15 NNW 3
3 0
0 0
7 Total 163 178 15 0
0 0
356 Calm Hours not Included above for:
Total Period All Hours 0
Variable Direction Hours for:
Total Period All Hours 0
Invalid Hours for:
Total Period All Hours 113 Number of Valid Hours for this Table:
Total Period All Hours 356 Total Hours for the Period:
2184 Page 5 of 8
Site:
VC Report Printed On: 03/21/2022 14:28 Joint Frequency Distribution Hours at Each Wind Speed and Direction Total Period All Hours Period of Record =
04/01/2021 01:00 - 07/01/2021 00:00 Elevation:
Speed:
SPlOTl Direction:
DRIOTI Lapse:
DT61Tl Stability Class:
F Delta Temperature Moderately Stable Wind Speed (mph)
Wind Direction 0.8-3.9 4.0-7.9 8.0-12.9 13.0-18.9 19.0-23.9
>24.0 Total N
2 0
0 0
0 0
2 NNE 1
0 0
0 0
0 1
NE 0
0 0
0 0
0 0
ENE 0
0 0
0 0
E 0
0 0
0 0
0 0
ESE 2
0 0
0 0
0 2
SE 6
5 0
0 0
0 11 SSE 16 12 0
0 0
0 28 s
8 15 0
0 0
0 23 SSW 16 12 0
0 0
0 28 SW 24 3
0 0
0 0
27 WSW 17 6
0 0
0 0
23 w
11 0
0 0
0 0
11 WNW 11 0
0 0
0 0
11 NW 3
0 0
0 0
0 3
NNW 2
3 0
0 0
0 5
Total 120 56 0
0 0
0 176 Calm Hours not Included above for:
Total Period All Hours 0
Variable Direction Hours for:
Total Period All Hours 0
Invalid Hours for:
Total Period All Hours 113 Number of Valid Hours for this Table:
Total Period All Hours 176 Total Hours for the Period:
2184 Page 6 of 8
Site:
VC Report Printed On: 03/21/2022 14:28 Joint Frequency Distribution Hours at Each Wind Speed and Direction Total Period All Hours Period of Record =
04/01/2021 01:00 - 07/01/2021 00:00 Elevation:
Speed:
SPIOTI Direction:
DRl0TI Lapse:
DT61Tl Stability Class:
G Delta Temperature Extremely Stable Wind Speed (mph)
Wind Direction 0.8-3.9 4.0-7.9 8.0-12.9 13.0-18.9 19.0-23.9
>24.0 Total N
0 0
0 0
0 NNE 1
0 0
0 0
0 NE 0
0 0
0 0
0 0
ENE 0
0 0
0 0
0 0
E 0
0 0
0 0
0 0
ESE 0
0 0
0 0
0 0
SE 1
I 0
0 0
0 2
SSE 9
8 0
0 0
0 17 s
15 3
0 0
0 0
18 SSW 16 2
0 0
0 0
18 SW 16 4
0 0
0 0
20 WSW 24 5
0 0
0 0
29 w
24 3
0 0
0 0
27 WNW 8
0 0
0 0
0 8
NW 4
0 0
0 0
5 NNW 2
0 0
0 0
0 2
Total 121 27 0
0 0
0 148 Calm Hours not Included above for:
Total Period All Hours 0
Variable Direction Hours for:
Total Period All Hours 0
Invalid Hours for:
Total Period All Hours 113 Number of Valid Hours for this Table:
Total Period All Hours 148 Total Hours for the Period:
2184 Page 7 of 8
Site:
VC Period of Record =
Elevation:
Speed:
SPIOTI Stability Class:
ALL Wind Direction 0.8-3.9 N
33 NNE 29 NE 16 ENE 11 E
8 ESE 3
76 WNW 55 NW 27 NNW 23 Total 658 Calm Hours not Included above for:
Variable Direction Hours for:
Invalid Hours for:
Number of Valid Hours for this Table:
Total Hours for the Period:
Page 8 of 8 Joint Frequency Distribution Hours at Each Wind Speed and Direction Total Period 04/01/2021 01 :00 - 07/01/2021 00:00 Direction:
DRIOTI Lapse:
DT61Tl Delta Temperature Wind Speed (mph) 4.0-7.9 8.0-12.9 13.0-18.9 19.0-23.9
>24.0 44 34 17 2
1 43 40 9
0 0
52 67 10 6
0 51 39 6
0 0
50 34 0
0 0
23 6
0 0
0 57 8
0 0
0 65 11 0
0 58 28 0
0 112 40 2
0 0
134 22 0
0 0
126 19 0
0 0
61 10 0
0 0
21 3
0 0
0 28 17 0
0 31 10 11 2
0 956 388 58 10 Total Period All Hours Total Period All Hours Total Period All Hours Total Period All Hours Report Printed On: 03/21/2022 14:28 All Hours Total 131 121 151 107 92 32 82 127 140 218 253 241 147 79 73 77 2071 0
0 113 2071 2184
Site:
VC Period of Record=
Elevation:
Speed:
SPIOTI Stability Class:
A Wind Direction 0.8-3.9 N
25 NNE 16 NE 12 ENE 1
E I
ESE 3
SE 0
SSE s
IO WNW 8
NW 5
NNW 7
Total I 15 Calm Hours not Included above for:
Variable Direction Hours for:
Invalid Hours for:
Number of Valid Hours for this Table:
Total Hours for the Period:
Page 1 of 8 Joint Frequency Distribution Hours at Each Wind Speed and Direction Total Period 07/01/2021 01 :00 - 10/01/2021 00:00 Direction:
DRIOTl Lapse:
DT61Tl Delta Temperature 4.0-7.9 8.0-12.9 28 7
28 9
27 12 13 8
5 I
2 0
2 2
0 2
7 10 6
6 29 1
20 0
15 I
8 0
5 3
8 203 63 Total Period Total Period Total Period Total Period Extremely Unstable Wind Speed (mph) 13.0-18.9 19.0-23.9 0
0 2
0 0
0 0
0 0
0 0
0 0
2 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
7 0
All Hours All Hours All Hours All Hours
>24.0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
Report Printed On: 03/21/2022 14:29 All Hours Total 61 54 53 23 7
5 4
3 19 13 42 33 26 16 13 16 388 0
0 0
388 2208
Site:
VC Report Printed On: 03/21/2022 14:29 Joint Frequency Distribution Hours at Each Wind Speed and Direction Total Period All Hours Period of Record =
07/01/2021 01:00 - 10/01/2021 00:00 Elevation:
Speed:
SPlOTl Direction:
DRl0Tl Lapse:
DT61Tl Stability Class:
B Delta Temperature Moderately Unstable Wind Speed (mph)
Wind Direction 0.8-3.9 4.0-7.9 8.0-12.9 13.0-18.9 19.0-23.9
>24.0 Total N
11 9
3 0
2 1
26 NNE 5
11 7
6 1
0 30 NE 7
9 1
0 0
18 ENE 6
0 0
0 8
E 0
4 4
0 0
0 8
ESE 0
2 l
0 0
0 3
SE 2
2 0
0 0
5 SSE 15 0
0 0
17 s
0 11 4
0 0
0 15 SSW 2
25 3
0 0
0 30 SW 12 25 0
0 0
0 37 WSW 9
2 0
0 0
0 11 w
2 2
0 0
0 0
4 WNW 5
2 0
0 0
8 NW 7
2 0
0 0
10 NNW 8
1 0
12 Total 66 120 43 8
4 242 Calm Hours not Included above for:
Total Period All Hours 0
Variable Direction Hours for:
Total Period All Hours 0
Invalid Hours for:
Total Period All Hours 0
Number of Valid Hours for this Table:
Total Period All Hours 242 Total Hours for the Period:
2208 Page 2 of8
Site:
VC Report Printed On: 03/21/2022 14:29 Joint Frequency Distribution Hours at Each Wind Speed and Direction Total Period All Hours Period of Record =
07/01/2021 01:00 - 10/01/2021 00:00 Elevation:
Speed:
SPlOTI Direction:
DRI0TI Lapse:
DT61TI Stability Class:
C Delta Temperature Slightly Unstable Wind Speed {mph)
Wind Direction 0.8-3.9 4.0-7.9 8.0-12.9 13.0-18.9 19.0-23.9
>24.0 Total N
5 4
2 5
0 0
16 NNE 2
4 15 4
0 0
25 NE 0
12 18 0
0 0
30 ENE 0
4 13 0
0 0
17 E
7 7
0 0
0 15 ESE 3
3 0
0 0
7 SE 2
10 1
0 0
0 13 SSE I
20 0
1 0
0 22 s
2 12 8
0 0
0 22 SSW I
26 0
0 0
0 27 SW 9
20 0
0 0
0 29 WSW 7
5 0
0 0
0 12 w
5 2
0 0
0 0
7 WNW 4
0 0
0 0
5 NW 0
2 0
0 0
0 2
NNW 2
4 0
0 0
7 Total 42 136 67 11 0
0 256 Calm Hours not Included above for:
Total Period All Hours 0
Variable Direction Hours for:
Total Period All Hours 0
Invalid Hours for:
Total Period All Hours 0
Number of Valid Hours for this Table:
Total Period AU Hours 256 Total Hours for the Period:
2208 Page 3 of 8
Site:
VC Report Printed On: 03/21/2022 14:29 Joint Frequency Distribution Hours at Each Wind Speed and Direction Total Period All Hours Period of Record=
07/01/2021 01:00 - 10/01/2021 00:00 Elevation:
Speed:
SPIOTI Direction:
DRl0Tl Lapse:
DT61Tl Stability Class:
D Delta Temperature Neutral Wind Speed (mph)
Wind Direction 0.8-3.9 4.0-7.9 8.0-12.9 13.0-18.9 19.0-23.9
>24.0 Total N
6 3
6 0
0 0
15 NNE 6
7 5
0 1
1 20 NE 4
19 5
0 30 ENE 3
25 13 0
0 42 E
7 29 21 0
0 0
57 ESE 5
10 0
0 0
0 15 SE 8
23 2
0 0
0 33 SSE 12 31 3
0 0
0 46 s
16 44 5
0 0
0 65 SSW 17 91 7
0 0
116 SW 31 24 1
0 0
0 56 WSW 22 10 0
0 0
0 32 w
21 3
0 0
0 0
24 WNW 20 0
0 0
0 0
20 NW II 6
0 0
0 0
17 NNW 4
6 0
0 0
0 10 Total 193 331 68 3
2 598 Calm Hours not Included above for:
Total Period All Hours 0
Variable Direction Hours for:
Total Period All Hours 0
Invalid Hours for:
Total Period All Hours 0
Number of Valid Hours for this Table:
Total Period All Hours 598 Total Hours for the Period:
2208 Page4 of 8
Site:
VC Report Printed On: 03/21/2022 14:29 Joint Frequency Distribution Hours at Each Wind Speed and Direction Total Period All Hours Period of Record=
07/01/2021 01 :00 - 10/01/2021 00:00 Elevation:
Speed:
SPlOTI Direction:
DRIOTI Lapse:
DT61Tl Stability Class:
E Delta Temperature Slightly Stable Wind Speed (mph)
Wind Direction 0.8-3.9 4.0-7.9 8.0-12.9 13.0-18.9 19.0-23.9
>24.0 Total N
2 8
2 0
0 0
12 NNE I
0 0
0 0
2 NE 1
0 I
0 0
0 2
ENE 0
0 0
0 0
1 E
2 2
0 0
0 0
4 ESE 0
0 0
0 0
SE 6
16 0
0 0
23 SSE 38 37 0
0 0
76 s
29 31 0
0 0
0 60 SSW 40 39 0
0 0
0 79 SW 55 4
0 0
0 0
59 WSW 36 2
0 0
0 0
38 w
17 4
0 0
0 0
21 WNW 19 0
0 0
0 0
19 NW 22 3
0 0
0 26 NNW 4
4 0
0 0
9 Total 273 152 7
0 0
0 432 Calm Hours not Included above for:
Total Period AU Hours 0
Variable Direction Hours for:
Total Period AU Hours 0
Invalid Hours for:
Total Period All Hours 0
Number of Valid Hours for this Table:
Total Period All Hours 432 Total Hours for the Period:
2208 Page 5 of 8
Site:
VC Report Printed On: 03/21/2022 14:29 Joint Frequency Distribution Hours at Each Wind Speed and Direction Total Period All Hours Period of Record=
07/01/2021 01 :00 - 10/01/2021 00:00 Elevation:
Speed:
SPlOTI Direction:
DRlOTl Lapse:
DT61Tl Stability Class:
F Delta Temperature Moderately Stable Wind Speed (mph)
Wind Direction 0.8-3.9 4.0-7.9 8.0-12.9 13.0-18.9 19.0-23.9
>24.0 Total N
0 0
0 0
0 0
0 NNE 0
0 0
0 0
0 0
NE 0
0 0
0 0
0 0
ENE 0
0 0
0 0
0 0
E 0
0 0
0 0
0 0
ESE 0
0 0
0 0
0 0
SE 2
4 0
0 0
0 6
SSE 13 13 0
0 0
0 26 s
19 6
0 0
0 0
25 SSW 22 7
0 0
0 0
29 SW 34 3
0 0
0 0
37 WSW 20 0
0 0
0 0
20 w
16 0
0 0
0 17 WNW 10 0
0 0
0 11 NW 7
0 0
0 0
8 NNW 4
0 0
0 0
5 Total 144 40 0
0 0
0 184 Calm Hours not Included above for:
Total Period AU Hours 0
Variable Direction Hours for:
Total Period AU Hours 0
Invalid Hours for:
Total Period All Hours 0
Number of Valid Hours for this Table:
Total Period All Hours 184 Total Hours for the Period:
2208 Page 6 of 8
Site:
VC Report Printed On: 03/21/2022 14:29 Joint Frequency Distribution Hours at Each Wind Speed and Direction Total Period All Hours Period of Record =
07/01/2021 01:00 - 10/01/2021 00:00 Elevation:
Speed:
SPlOTl Direction:
DRlOTl Lapse:
DT61TI Stability Class:
G Delta Temperature Extremely Stable Wind Speed (mph)
Wind Direction 0.8-3.9 4.0-7.9 8.0-12.9 13.0-18.9 19.0-23.9
>24.0 Total N
0 0
0 0
0 0
0 NNE 0
0 0
0 0
0 0
NE 0
0 0
0 0
0 0
ENE 0
0 0
0 0
0 0
E 0
0 0
0 0
0 0
ESE 0
0 0
0 0
0 0
SE 0
0 0
0 0
0 0
SSE 2
1 0
0 0
0 3
s 6
0 0
0 0
7 SSW 17 1
0 0
0 19 SW 28 6
0 0
0 0
34 WSW 19 0
0 0
0 0
19 w
18 0
0 0
0 0
18 WNW 6
0 0
0 0
0 6
NW 2
0 0
0 0
0 2
NNW 0
0 0
0 0
0 0
Total 98 9
0 0
0 108 Calm Hours not Included above for:
Total Period All Hours 0
Variable Direction Hours for:
Total Period All Hours 0
Invalid Hours for:
Total Period All Hours 0
Number of Valid Hours for this Table:
Total Period All Hours 108 Total Hours for the Period:
2208 Page 7 of8
Site:
VC Period of Record =
Elevation:
Speed:
SPlOTl Stability Class:
ALL Wind Direction 0.8-3.9 N
49 NNE 30 NE 18 ENE 5
89 WNW 72 NW 54 NNW 26 Total 931 Calm Hours not Included above for:
Variable Direction Hours for:
Invalid Hours for:
Number of Valid Hours for this Table:
Total Hours for the Period:
Page 8 of 8 Joint Frequency Distribution Hours at Each Wind Speed and Direction Total Period 07/01/2021 01 :00 - 10/01/2021 00:00 Direction:
DRlOTl Lapse:
DT61Tl Delta Temperature Wind Speed (mph) 4.0-7.9 8.0-12.9 13.0-18.9 19.0-23.9
>24.0 52 20 6
2 51 36 11 2
65 45 4
0 44 40 2
0 0
47 33 0
0 0
17 4
0 0
0 56 8
0 0
0 117 7
0 0
112 27 2
0 0
195 17 0
0 111 2
0 0
0 39 0
0 0
0 27 0
0 0
12 0
0 0
19 5
0 0
0 27 3
2 0
991 249 29 6
2 Total Period All Hours Total Period All Hours Total Period All Hours Total Period All Hours Report Printed On: 03/21/2022 14:29 All Hours Total 130 131 133 91 91 31 84 193 213 313 294 165 117 85 78 59 2208 0
0 0
2208 2208
Site:
VC Period of Record =
Elevation:
Stability Class:
Wind Direction N
NNE NE ENE E
WNW NW NNW Total Speed:
SPlOTl A
0.8-3.9 5
3 0
2 1
0 0
0 0
0 3
5 2
4 4
11 40 Calm Hours not Included above for:
Variable Direction Hours for:
Invalid Hours for:
Number of Valid Hours for this Table:
Total Hours for the Period:
Page 1 of 8 Joint Frequency Distribution Hours at Each Wind Speed and Direction Total Period 10/01/2021 01 :00 - 01/01/2022 00:00 Direction:
DRIOTl Lapse:
DT61Tl Delta Temperature Extremely Unstable Wind Speed (mph) 4.0-7.9 8.0-12.9 13.0-18.9 19.0-23.9
>24.0 15 14 15 11 0
IO 15 13 7
1 15 30 14 0
0 3
4 0
0 0
6 1
0 0
0 4
2 0
0 0
1 0
0 0
0 0
0 0
0 0
2 0
0 0
0 7
8 3
0 0
40 6
0 0
0 23 8
0 0
0 10 2
0 0
0 IO 0
0 0
0 14 3
0 0
0 II 7
4 l
0 171 100 49 19 Total Period All Hours Total Period All Hours Total Period All Hours Total Period All Hours Report Printed On: 03/21/2022 14:30 All Hours Total 60 49 59 9
8 6
I 0
2 18 49 36 14 14 21 34 380 0
0 1
380 2208
Site:
VC Period of Record =
Elevation:
Speed:
SPlOTI Stability Class:
B Wind Direction 0.8-3.9 N
NNE 2
NE 3
ENE 0
E 2
ESE l
SE 0
SSE s
2 SSW 0
SW 0
WSW 4
w 4
WNW 5
NW 4
NNW 5
Total 34 Calm Hours not Included above for:
Variable Direction Hours for:
Invalid Hours for:
Number of Valid Hours for this Table:
Total Hours for the Period:
Page 2 of 8 Joint Frequency Distribution Hours at Each Wind Speed and Direction Total Period 10/01/2021 01:00 - 01/01/2022 00:00 Direction:
DRIOTI Lapse:
DT61Tl Delta Temperature Moderately Unstable Wind Speed (mph) 4.0-7.9 8.0-12.9 13.0-18.9 19.0-23.9
>24.0 8
5 11 4
0 6
14 14 2
0 7
27 13 0
0 9
11 0
0 9
2 0
0 0
5 3
0 0
0 0
0 0
0 0
0 0
0 0
0 3
0 0
0 0
2 4
1 0
0 15 0
0 0
12 0
0 0
0 4
I 0
0 0
3 0
0 0
0 6
0 0
0 0
8 5
3 0
0 97 73 43 6
0 Total Period All Hours Total Period All Hours Total Period All Hours Total Period All Hours Report Printed On: 03/21/2022 14:30 All Hours Total 29 38 50 21 13 9
0 5
7 16 16 9
8 10 21 253 0
0 I
253 2208
Site:
VC Period of Record =
Elevation:
Speed:
SPlOTI Stability Class:
C Wind Direction 0.8-3.9 N
2 NNE 2
NE 0
ENE 3
E 0
ESE SE 2
SSE 0
s 0
SSW 2
SW 4
WSW 7
w 3
WNW 5
NW 1
NNW 2
Total 34 Calm Hours not Included above for:
Variable Direction Hours for:
Invalid Hours for:
Number of Valid Hours for this Table:
Total Hours for the Period:
Page 3 of 8 Joint Frequency Distribution Hours at Each Wind Speed and Direction Total Period 10/01/2021 01 :00 - 01/01/2022 00:00 Direction:
DRIOTI Lapse:
DT61Tl Delta Temperature 4.0-7.9 8.0-12.9 4
4 8
6 10 3
2 4
8 7
21 4
2 5
2 91 Total Period Total Period Total Period Total Period 4
11 23 23 3
2 0
0 2
l 0
0 0
72 Slightly Unstable Wind Speed (mph) 13.0-18.9 5
4 4
0 0
0 0
0 0
0 0
0 0
0 0
5 18 19.0-23.9 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
All Hours All Hours All Hours All Hours
>24.0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
Report Printed On: 03/21/2022 14:30 All Hours Total 15 21 35 32 13 5
6 4
8 11 26 12 4
7 6
10 215 0
0 215 2208
Site:
VC Report Printed On: 03/21/2022 14:30 Joint Frequency Distribution Hours at Each Wind Speed and Direction Total Period All Hours Period of Record =
10/01/2021 01:00 - 01/01/2022 00:00 Elevation:
Speed:
SPlOTl Direction:
DRIOTI Lapse:
DT61Tl Stability Class:
D Delta Temperature Neutral Wind Speed (mph)
Wind Direction 0.8-3.9 4.0-7.9 8.0-12.9 13.0-18.9 19.0-23.9
>24.0 Total N
10 8
3 1
0 0
22 NNE 5
6 3
1 0
0 15 NE 8
19 11 5
0 0
43 ENE 3
12 3
0 0
0 18 E
2 31 21 0
0 0
54 ESE 3
8 3
0 0
0 14 SE 2
9 0
0 0
12 SSE 5
12 0
0 0
0 17 s
6 25 6
0 0
0 37 SSW 10 64 5
0 0
0 79 SW 17 58 1
0 0
0 76 WSW 30 28 1
0 0
0 59 w
23 14 0
0 0
0 37 WNW 10 6
0 0
0 0
16 NW 7
9 2
0 0
0 18 NNW 3
5 5
2 0
0 15 Total 144 314 65 9
0 0
532 Calm Hours not Included above for:
Total Period All Hours 0
Variable Direction Hours for:
Total Period All Hours 0
Invalid Hours for:
Total Period All Hours Number of Valid Hours for this Table:
Total Period All Hours 532 Total Hours for the Period:
2208 Page 4 of 8
Site:
VC Report Printed On: 03/21/2022 14:30 Joint Frequency Distribution Hours at Each Wind Speed and Direction Total Period All Hours Period of Record =
10/01/2021 01:00 - 01/01/2022 00:00 Elevation:
Speed:
SPlOTl Direction:
DRlOTl Lapse:
DT61Tl Stability Class:
E Delta Temperature Slightly Stable Wind Speed (mph)
Wind Direction 0.8-3.9 4.0-7.9 8.0-12.9 13.0-18.9 19.0-23.9
>24.0 Total N
10 5
0 0
0 0
15 NNE 6
2 1
0 0
0 9
NE 7
4 0
0 0
0 11 ENE 0
1 0
0 0
0 E
2 2
0 0
0 0
4 ESE 5
l 0
0 0
7 SE 5
5 0
0 0
0 10 SSE 10 8
0 0
0 0
18 s
11 29 0
0 0
0 40 SSW 17 35 0
0 0
53 SW 35 28 0
0 0
0 63 WSW 20 10 0
0 0
0 30 w
17 8
0 0
0 0
25 WNW 9
4 0
0 0
0 13 NW 5
9 0
0 0
0 14 NNW 5
4 2
0 0
0 11 Total 164 155 5
0 0
0 324 Calm Hours not Included above for:
Total Period All Hours 0
Variable Direction Hours for:
Total Period All Hours 0
Invalid Hours for:
Total Period All Hours Number of Valid Hours for this Table:
Total Period All Hours 324 Total Hours for the Period:
2208 Page 5 of 8
Site:
VC Report Printed On: 03/21/2022 14:30 Joint Frequency Distribution Hours at Each Wind Speed and Direction Total Period All Hours Period of Record =
10/01/2021 01 :00 - 01/01/2022 00:00 Elevation:
Speed:
SPIOTI Direction:
DRIOTI Lapse:
DT61Tl Stability Class:
F Delta Temperature Moderately Stable Wind Speed (mph)
Wind Direction 0.8-3.9 4.0-7.9 8.0-12.9 13.0-18.9 19.0-23.9
>24.0 Total N
4 2
0 0
0 0
6 NNE 0
3 0
0 0
0 3
NE 3
0 0
0 0
0 3
ENE 3
0 0
0 0
0 3
E 2
0 0
0 0
0 2
ESE 0
0 0
0 0
0 0
SE 5
4 0
0 0
0 9
SSE 6
8 0
0 0
0 14 s
23 28 0
0 0
0 51 SSW 27 12 0
0 0
0 39 SW 41 3
0 0
0 0
44 WSW 24 0
0 0
0 25 w
16 0
0 0
0 17 WNW 17 0
0 0
0 0
17 NW 6
3 0
0 0
0 9
NNW 2
0 0
0 0
0 2
Total 179 65 0
0 0
0 244 Calm Hours not Included above for:
Total Period All Hours 0
Variable Direction Hours for:
Total Period All Hours 0
Invalid Hours for:
Total Period All Hours Number of Valid Hours for this Table:
Total Period All Hours 244 Total Hours for the Period:
2208 Page 6 of 8
Site:
VC Report Printed On: 03/21/2022 14:30 Joint Frequency Distribution Hours at Each Wind Speed and Direction Total Period All Hours Period of Record =
10/01/2021 01:00 - 01/01/2022 00:00 Elevation:
Speed:
SPIOTI Direction:
DRIOTI Lapse:
DT61Tl Stability Class:
G Delta Temperature Extremely Stable Wind Speed (mph)
Wind Direction 0.8-3.9 4.0-7.9 8.0-12.9 13.0-18.9 19.0-23.9
>24.0 Total N
0 0
0 0
0 0
0 NNE 2
0 0
0 0
0 2
NE 0
0 0
0 0
I ENE 0
0 0
0 0
0 0
E 0
0 0
0 0
0, 0
ESE 3
0 0
0 0
0 3
SE 0
0 0
0 0
0 0
SSE 8
2 0
0 0
0 10 s
19 4
0 0
0 0
23 SSW 20 3
0 0
0 0
23 SW 57 3
0 0
0 0
60 WSW 65 0
0 0
0 0
65 w
34 2
0 0
0 0
36 WNW 27 I
0 0
0 0
28 NW 6
2 0
0 0
0 8
NNW 0
0 0
0 0
0 0
Total 242 17 0
0 0
0 259 Calm Hours not Included above for:
Total Period All Hours 0
Variable Direction Hours for:
Total Period All Hours 0
Invalid Hours for:
Total Period All Hours Number of Valid Hours for this Table:
Total Period All Hours 259 Total Hours for the Period:
2208 Page 7 of 8
Site:
VC Period of Record =
Elevation:
Speed:
SPl0Tl Stability Class:
ALL Wind Direction 0.8-3.9 N
32 NNE 20 NE 22 ENE 11 E
99 WNW 77 NW 33 NNW 28 Total 837 Calm Hours not Included above for:
Variable Direction Hours for:
Invalid Hours for:
Number of Valid Hours for this Table:
Total Hours for the Period:
Page 8 of 8 Joint Frequency Distribution Hours at Each Wind Speed and Direction Total Period 10/01/2021 01:00 - 01/01/2022 00:00 Direction:
DRlOTl Lapse:
DT61Tl Delta Temperature Wind Speed (mph) 4.0-7.9 8.0-12.9 13.0-18.9 19.0-23.9
>24.0 42 26 32 15 0
31 44 32 9
1 53 91 36 0
0 31 41 0
0 58 27 0
0 0
21 10 0
0 0
21 3
0 0
0 34 0
0 0
0 99 6
0 0
0 130 20 4
0 0
168 9
0 0
0 78 10 0
0 0
40 3
0 0
0 26 0
0 0
0 48 5
0 0
0 30 20 14 0
910 315 119 25 Total Period All Hours Total Period AU Hours Total Period All Hours Total Period All Hours Report Printed On: 03/21/2022 14:30 All Hours Total 147 137 202 84 94 44 38 64 166 230 334 243 142 103 86 93 2207 0
0 2207 2208
Annual Summary
Site:
VC Period of Record =
Elevation:
Stability Class:
Wind Direction N
NNE NE ENE E
WNW NW NNW Total Speed:
SPIOTI A
0.8-3.9 54 37 20 3
2 3
0 1
2 22 33 30 24 18 30 280 Calm Hours not Included above for:
Variable Direction Hours for:
Invalid Hours for:
Number of Valid Hours for this Table:
Total Hours for the Period:
Page 1 of 8 Joint Frequency Distribution Hours at Each Wind Speed and Direction Total Period 01/01/2021 01:00 - 01/01/2022 00:00 Direction:
DRIOTl Lapse:
DT61TI Delta Temperature Extremely Unstable Wind Speed (mph) 4.0-7.9 8.0-12.9 13.0-18.9 19.0-23.9
>24.0 80 34 24 13 74 34 20 7
I 79 70 29 0
0 37 32 4
0 0
20 13 1
0 0
9 4
0 0
0 4
2 0
0 0
2 6
0 0
0 11 16 3
0 0
31 27 3
0 135 28 I
0 0
120 24 0
0 0
74 22 0
0 0
46 0
0 0
0 39 26 0
0 43 17 11 2
0 804 355 97 23 2
Total Period All Hours Total Period All Hours Total Period All Hours Total Period All Hours Report Printed On: 03/21/2022 14:12 All Hours Total 206 173 198 76 36 16 6
9 32 63 186 177 126 70 84 103 1561 0
114 1561 8760
Site:
VC Period of Record =
Elevation:
Stability Class:
Wind Direction N
NNE NE ENE E
WNW NW NNW Total Speed:
SPlOTl B
0.8-3.9 22 12 8
2 4
1 3
2 4
3 15 18 8
14 18 18 152 Calm Hours not Included above for:
Variable Direction Hours for:
Invalid Hours for:
Number of Valid Hours for this Table:
Total Hours for the Period:
Page 2 of 8 Joint Frequency Distribution Hours at Each Wind Speed and Direction Total Period 01/01/2021 01:00 - 01/01/2022 00:00 Direction:
DRIOTI Lapse:
DT61Tl Delta Temperature Moderately Unstable Wind Speed (mph) 4.0-7.9 8.0-12.9 13.0-18.9 19.0-23.9
>24.0 30 19 23 6
25 50 51 5
0 22 65 42 4
0 17 20 2
0 0
19 12 0
0 0
11 5
0 0
0 3
3 0
0 0
19 7
0 0
0 20 14 1
0 0
39 13 3
2 0
66 6
0 0
0 29 3
0 0
0 16 0
0 0
8 2
0 0
0 14 3
0 0
0 17 14 8
2 0
355 237 130 19 Total Period All Hours Total Period All Hours Total Period All Hours Total Period All Hours Report Printed On: 03/21/2022 14:12 All Hours Total 101 143 141 41 35 17 9
28 39 60 87 50 25 24 35 59 894 1
0 114 894 8760
Site:
VC Report Printed On: 03/21/2022 14:12 Joint Frequency Distribution Hours at Each Wind Speed and Direction Total Period All Hours Period of Record =
01/01/2021 01:00 - 01/01/2022 00:00 Elevation:
Speed:
SPlOTI Direction:
DRIOTI Lapse:
DT61Tl Stability Class:
C Delta Temperature Slightly Unstable Wind Speed (mph)
Wind Direction 0.8-3.9 4.0-7.9 8.0-12.9 13.0-18.9 19.0-23.9
>24.0 Total N
13 23 29 16 0
0 81 NNE 7
18 88 32 0
0 145 NE 1
37 114 24 2
0 178 ENE 4
24 70 IO 0
0 108 E
2 22 34 0
0 0
58 ESE 2
13 9
0 0
0 24 SE 6
24 6
0 0
0 36 SSE 3
40 3
2 0
0 48 s
3 37 23 0
0 0
63 SSW 7
50 11 0
0 69 SW 18 51 3
0 0
0 72 WSW 17 28 2
0 0
0 47 w
IO 14 0
0 0
25 WNW 14 5
0 0
0 0
19 NW 6
13 3
0 0
0 22 NNW 7
18 5
10 0
0 40 Total 120 417 401 95 2
0 1035 Calm Hours not Included above for:
Total Period AU Hours Variable Direction Hours for:
Total Period All Hours 0
Invalid Hours for:
Total Period All Hours 114 Number of Valid Hours for this Table:
Total Period All Hours 1035 Total Hours for the Period:
8760 Page 3 of 8
Site:
VC Period of Record =
Elevation:
Stability Class:
Wind Direction N
NNE NE ENE E
WNW NW NNW Total Speed:
SPl0TI D
0.8-3.9 22 26 16 15 12 13 16 35 37 51 87 80 78 51 34 14 587 Calm Hours not Included above for:
Variable Direction Hours for:
Invalid Hours for:
Number of Valid Hours for this Table:
Total Hours for the Period:
Page 4 of 8 Joint Frequency Distribution Hours at Each Wind Speed and Direction Total Period 01/01/2021 01 :00 - 01/01/2022 00:00 Direction:
DRlOTl Lapse:
DT61TI Delta Temperature 4.0-7.9 8.0-12.9 27 29 67 87 131 41 81 75 102 203 151 99 54 27 41 20 1235 Total Period Total Period Total Period Total Period 28 27 65 57 71 7
14 7
21 42 10 6
3 14 18 391 Neutral Wind Speed (mph) 13.0-18.9 19.0-23.9
>24.0 4
0 0
8 1
13 3
0 6
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
I 0
0 6
0 0
40 4
All Hours All Hours All Hours All Hours Report Printed On: 03/21/2022 14:12 All Hours Total 81 92 164 165 214 61 111 117 161 297 248 185 133 81 90 58 2258 0
114 2258 8760
Site:
VC Report Printed On: 03/21/2022 14: 12 Joint Frequency Distribution Hours at Each Wind Speed and Direction Total Period All Hours Period of Record =
01/01/2021 01 :00 - 01/01/2022 00:00 Elevation:
Speed:
SPIOTI Direction:
DRlOTl Lapse:
DT61Tl Stability Class:
E Delta Temperature Slightly Stable Wind Speed (mph)
Wind Direction 0.8-3.9 4.0-7.9 8.0-12.9 13.0-18.9 19.0-23.9
>24.0 Total N
22 26 7
0 0
0 55 NNE 17 19 7
0 0
0 43 NE 15 17 5
0 0
0 37 ENE 5
18 2
0 0
0 25 E
11 25 2
0 0
0 38 ESE 13 14 0
0 0
28 SE 25 49 1
0 0
0 75 SSE 72 86 2
0 0
0 160 s
67 82 2
0 0
0 151 SSW 92 143 7
0 0
0 242 SW 149 68 0
0 0
218 WSW 112 35 0
0 0
0 147 w
69 32 0
0 0
102 WNW 57 14 0
0 0
0 71 NW 43 32 2
0 0
0 77 NNW 20 22 8
0 0
0 50 Total 789 682 48 0
0 0
1519 Calm Hours not Included above for:
Total Period All Hours 1
Variable Direction Hours for:
Total Period All Hours 0
Invalid Hours for:
Total Period All Hours 114 Number of Valid Hours for this Table:
Total Period All Hours 1519 Total Hours for the Period:
8760 Page 5 of 8
Site:
VC Report Printed On: 03/21/2022 14:12 Joint Frequency Distribution Hours at Each Wind Speed and Direction Total Period All Hours Period of Record =
01/01/2021 01:00 - 01/01/2022 00:00 Elevation:
Speed:
SPIOT!
Direction:
DRIOTl Lapse:
DT61Tl Stability Class:
F Delta Temperature Moderately Stable Wind Speed (mph)
Wind Direction 0.8-3.9 4.0-7.9 8.0-12.9 13.0-18.9 19.0-23.9
>24.0 Total N
12 4
0 0
0 0
16 NNE 4
3 0
0 0
0 7
NE 4
0 0
0 0
0 4
ENE 5
0 0
0 0
0 5
E 4
0 0
0 0
0 4
ESE 6
0 0
0 0
0 6
SE 17 24 0
0 0
0 41 SSE 46 42 0
0 0
0 88 s
56 62 0
0 0
0 118 SSW 78 40 0
0 0
0 118 SW 113 16 0
0 0
0 129 WSW 69 13 0
0 0
0 82 w
49 6
0 0
0 0
55 WNW 49 2
0 0
0 0
51 NW 29 IO 0
0 0
0 39 NNW 7
7 0
0 0
0 14 Total 548 229 0
0 0
0 777 Calm Hours not Included above for:
Total Period All Hours Variable Direction Hours for:
Total Period All Hours 0
Invalid Hours for:
Total Period All Hours 114 Number of Valid Hours for this Table:
Total Period All Hours 777 Total Hours for the Period:
8760 Page 6 of 8
Site:
VC Report Printed On: 03/21/2022 14:12 Joint Frequency Distribution Hours at Each Wind Speed and Direction Total Period All Hours Period of Record =
01/01/2021 01:00 - 01/01/2022 00:00 Elevation:
Speed:
SPIOTI Direction:
DRIOTI Lapse:
DT61Tl Stability Class:
G Delta Temperature Extremely Stable Wind Speed (mph)
Wind Direction 0.8-3.9 4.0-7.9 8.0-12.9 13.0-18.9 19.0-23.9
>24.0 Total N
1 1
0 0
0 0
2 NNE 5
0 0
0 0
0 5
NE 2
0 0
0 0
0 2
ENE 0
0 0
0 0
0 0
E 0
0 0
0 0
0 0
ESE 3
0 0
0 0
0 3
SE 2
0 0
0 0
3 SSE 23 12 0
0 0
0 35 s
45 12 0
0 0
0 57 SSW 59 8
1 0
0 0
68 SW 112 17 0
0 0
0 129 WSW 126 6
0 0
0 0
132 w
83 5
0 0
0 0
88 WNW 48 0
0 0
0 49 NW 19 5
0 0
0 0
24 NNW 4
0 0
0 0
0 4
Total 532 68 0
0 0
601 Calm Hours not Included above for:
Total Period AU Hours 1
Variable Direction Hours for:
Total Period All Hours 0
Invalid Hours for:
Total Period All Hours 114 Number of Valid Hours for this Table:
Total Period All Hours 601 Total Hours for the Period:
8760 Page 7 of 8
Site:
VC Period of Record =
Elevation:
Speed:
SPlOTI Stability Class:
ALL Wind Direction 0.8-3.9 N
146 NNE 108 NE 66 ENE 34 E
327 WNW 257 NW 167 NNW 100 Total 3008 Calm Hours not Included above for:
Variable Direction Hours for:
Invalid Hours for:
Number of Valid Hours for this Table:
Total Hours for the Period:
Page 8 of8 Joint Frequency Distribution Hours at Each Wind Speed and Direction Total Period 01/01/2021 01:00 - 01/01/2022 00:00 Direction:
DRl0Tl Lapse:
DT61Tl Delta Temperature Wind Speed (mph) 4.0-7.9 8.0-12.9 13.0-18.9 19.0-23.9
>24.0 191 117 67 19 2
168 206 111 13 2
222 319 108 9
0 183 181 22 0
0 217 132 0
0 88 26 0
0 0
186 26 0
0 0
276 25 2
0 0
326 76 5
0 0
514 101 8
3 0
504 48 1
0 0
330 35 0
0 0
201 26 0
0 0
103 5
0 0
0 154 48 2
0 0
127 62 35 4
0 3790 1433 362 48 4
Total Period AU Hours Total Period AU Hours Total Period All Hours Total Period All Hours Report Printed On: 03/21/2022 14:12 All Hours Total 542 608 724 420 385 155 281 485 621 917 1069 820 554 365 371 328 8645 1
0 114 8645 8760
ENCLOSURE B ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT JANUARY - DECEMBER 2021 VIRGIL C. SUMMER NUCLEAR STATION Errata/Correction to Previous ARERR
ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT JANUARY - DECEMBER 2020 Virgil C. Summer Nuclear Station TABLE 1 Gaseous Effluents-Summation of All Releases Type of Effluent Units Qtr 1 Qtr2 Qtr3 Qtr4 A. Fission & Activation Gases
- 1. Total Release Curies 0.00E+00 8.28E-01 1.45E-02 0.00E+00
- 2. Average Release Rate for Period
µCi/sec 0.00E+00 1.0SE-01 1.83E-03 0.00E+00
- 3. Percent of Applicable Limit 0.00E+00 2.00E-02 3.23E-05 0.00E+00 B. Iodines
- 1. Total lodine-131 Curies 0.00E+00 3.32E-06 0.00E+00 0.00E+00
- 2. Average Release Rate for Period
µCi/sec 0.00E+00 4.23E-07 0.00E+00 0.00E+00
- 3. Percent of Applicable Limit 0.00E+00 3.32E-04 0.00E+00 0.00E+00 C. Particulates
- 1. Total Particulates (Half-lives> 8 days)
Curies 9.49E-06 0.00E+00 3.47E-06 1.0SE-05
- 2. Average Release Rate for Period
µCi/sec 1.21E-06 0.00E+00 4.36E-07 1.32E-06
- 3. Percent of Applicable Limit 0.00E+00 0.00E+00 0.00E+00 0.00E+00
- 4. Gross Alpha Activity Curies 0.00E+00 0.00E+00 0.00E+00 0.00E+00 D. Tritium
- 1. Total Release Curies 0.00E+00 1.82E+00 0.00E+00 0.00E+00
- 2. Average Release Rate for Period
µCi/sec 0.00E+00 2.32E-01 0.00E+00 0.00E+00
- 3. Percent of Applicable Limit 0.00E+00 1.38E-02 0.00E+00 0.00E+00 E. Carbon-14
- 1. Total Release Curies 2.26E+00 2.26E+00 2.28E+00 2.28E+00
- 2. Average Release Rate for Period
µCi/sec 2.87E-01 2.87E-01 2.87E-01 2.87E-01 Error%
2.00E+01 2.50E+01 2.50E+01 0.00E+00 2.00E+01 NIA