IR 05000395/2023011

From kanterella
Jump to navigation Jump to search
Focused Engineering Inspection Report 05000395/2023011
ML23270A000
Person / Time
Site: Summer 
Issue date: 09/27/2023
From: James Baptist
Division of Reactor Safety II
To: Carr E
Dominion Energy
References
IR 2023011
Download: ML23270A000 (1)


Text

SUBJECT:

VIRGIL C. SUMMER NUCLEAR STATION - FOCUSED ENGINEERING INSPECTION REPORT 05000395/2023011

Dear Eric S. Carr:

On August 31, 2023, the U.S. Nuclear Regulatory Commission (NRC) completed an inspection at Virgil C. Summer Nuclear Station and discussed the results of this inspection with Mr. Robert Justice and other members of your staff. The results of this inspection are documented in the enclosed report.

No findings or violations of more than minor significance were identified during this inspection.

This letter, its enclosure, and your response (if any) will be made available for public inspection and copying at http://www.nrc.gov/reading-rm/adams.html and at the NRC Public Document Room in accordance with Title 10 of the Code of Federal Regulations 2.390, Public Inspections, Exemptions, Requests for Withholding.

Sincerely, James B. Baptist, Chief Engineering Branch 1 Division of Reactor Safety Docket No. 05000395 License No. NPF-12

Enclosure:

As stated

Inspection Report

Docket Number:

05000395

License Number:

NPF-12

Report Number:

05000395/2023011

Enterprise Identifier:

I-2023-011-0028

Licensee:

Dominion Energy

Facility:

Virgil C. Summer Nuclear Station

Location:

Jenkinsville, SC

Inspection Dates:

August 14, 2023 to August 31, 2023

Inspectors:

P. Carman, Senior Reactor Inspector

C. Franklin, Reactor Inspector

T. Su, Reactor Inspector

Approved By:

James B. Baptist, Chief

Engineering Branch 1

Division of Reactor Safety

SUMMARY

The U.S. Nuclear Regulatory Commission (NRC) continued monitoring the licensees performance by conducting a focused engineering inspection at Virgil C. Summer Nuclear Station, in accordance with the Reactor Oversight Process. The Reactor Oversight Process is the NRCs program for overseeing the safe operation of commercial nuclear power reactors.

Refer to https://www.nrc.gov/reactors/operating/oversight.html for more information.

List of Findings and Violations

No findings or violations of more than minor significance were identified.

Additional Tracking Items

None.

INSPECTION SCOPES

Inspections were conducted using the appropriate portions of the inspection procedures (IPs) in effect at the beginning of the inspection unless otherwise noted. Currently approved IPs with their attached revision histories are located on the public website at http://www.nrc.gov/reading-rm/doc-collections/insp-manual/inspection-procedure/index.html. Samples were declared complete when the IP requirements most appropriate to the inspection activity were met consistent with Inspection Manual Chapter (IMC) 2515, Light-Water Reactor Inspection Program - Operations Phase. The inspectors reviewed selected procedures and records, observed activities, and interviewed personnel to assess licensee performance and compliance with Commission rules and regulations, license conditions, site procedures, and standards.

REACTOR SAFETY

71111.21N.03 - Commercial Grade Dedication Commercial Grade Dedication (section 03.01)

The inspectors reviewed the implementation of the licensees processes for dedicating commercial-grade items/services as basic components and/or for procuring safety-related structures, systems, and components for the following samples:

(1)03-3131-0097-13, Gauge, Pressure, 0-100#X4 1/2FACEX1/4LC, Ashcroft, Part# 45-1279SS-02L-XMQNHPD6N-100#

(2)26-1126-0102-12, Capacitor, 5400MFD, -10+50%VDC, 200VDC, 250 Surge, Phillips P/N 3186GH542T200AMA1, Cornell Dubilier P/N 3186GH542T200AMA1 (XIT5903/-

5904)

(3)30-0691-0713-13, Bearing, FAFNIR, 309KDD (4)30-3129-9022-13, Gasket, Spiral Wound, 1.50, 150#

(5)30-8091-0920-13, Seal, Poppet, Viton with GR A Type Curative, DWG#SCE&G 1MS-69-050 (6)35-0702-0025-12, V-Belt, Browning 62.2, Part #A60.2/Set (7)42495888, O-Ring, Valve Housing Assembly, FR-34, Group 504-022, PC 332, Nitrile, for Colt Diesel Generator P/N 0N65234.53.60 (8)54-2763-0011-13, Fuse, 1 amp, 250 vac, Time Delay (9)54-0955-6108-13, Breaker, Circuit, 8A, 2P, Alltech, P/N 2G8UM (10)67-5346-0054-13, Lubricant, Chevron SRI 2 Grease, 14oz (11)96-8091-0135-12, Seat, Valve, Ring, for 16"-150# Butterfly (12)96-9122-2150-13, Henry Pratt 20" 150# Butterfly Valve (CC Heat Exchanger B Isolation XVB3122B)

INSPECTION RESULTS

No findings were identified.

EXIT MEETINGS AND DEBRIEFS

The inspectors verified no proprietary information was retained or documented in this report.

On August 31, 2023, the inspectors presented the focused engineering inspection results to Mr. Robert Justice and other members of the licensee staff.

DOCUMENTS REVIEWED

Inspection

Procedure

Type

Designation

Description or Title

Revision or

Date

Corrective Action

Documents

CR-20-01409,

CR-16-00953,

CR-20-02668,

CR-21-01273,

CR-21-02798,

CR-21-03178,

CR-21-03179,

CR-21-03266,

CR-12-19603,

CR-20-02668,

CR-21-01273,

CR-21-02798,

CR-21-03178,

CR-21-03179,

CR-21-03266,

CR-12-19603

CR1235580

Typographical error noted during NRC Inspection

8/15/2023

CR1235748

Procedure Reference Error noted during NRC Inspection

8/17/2023

CR1235757

Missing QA documentation: V-belts in Safety Related

locations XAH0032, XAH0009A and XAH0009B

8/17/2023

CR1236410

Discrepancy in CP-400 Worked Penetration range for SRI-

grease.

8/28/2023

Corrective Action

Documents

Resulting from

Inspection

CR1236588

Discrepancy in CP-400 Dropping Point range for SRI-2

grease.

8/30/2023

1MS-69-050

Seal, Poppet, Viton

Drawings

1MS-69-064

Mechanical Bearing Specifications Fafnir 300K & 300KDD

Series

EQDP-H-MO2-

R07

Environmental Qualification Document Package

EQDP-H-VO5-

L01

Environmental Qualification Document Package Interim

Change Package 4-A

71111.21N.03

Engineering

Evaluations

ETBT-ECR-

Replacement of XVB03123B-SW

Inspection

Procedure

Type

Designation

Description or Title

Revision or

Date

2676

PTE

10000064364

VCS - Supplemental Fuses E2

PTE

10000066596

VCS - Ashcroft Pressure Gauges (E2S)

PTE

10000072193

Spare Parts (non-ASME) for NLI Chillers

PTE-

10000062800

Procurement Technical Evaluation: VCS - HVAC System -

V-Belts

PTE-

10000063296

Procurement Technical Evaluation: VCS-

Elastomers/Gaskets-MSIVs & FWIVs

PTE-

10000070146

Procurement Technical Evaluation: VCS-Specialty Seals-

FWIVs/MSIVs (Poppet Seals)

PTE-

10000070184

Procurement Technical Evaluation: Various, non-ASME

parts and components supplied by Fairbanks Morse

(Material with shelf life)

01/30/2023

PTE-

10000072460

Procurement Technical Evaluation: VCS-Inter-Utility

Purchase (EDG Parts)

1/24/2023

SLC-18

Shelf Life Evaluation: Power Transmission Belts (V-Belts)

SLC-2

Shelf Life Evaluation: Natural or Synthetic Rubbers

(Elastomers) in the Form of Packing Rings, Seal Rings, O-

Rings, Diaphragms, Gaskets

SLC-38

Shelf Life Criteria, Bearings, double shielded, Fafnir, suffix

- KDD

SLC-4

Shelf Life Criteria, Grease lubricants

1MS-94B-0750

Operation and Maintenance Manul SCE&G, VC Summer

Standby EDG Set Colt-13-206152. Volumes I & II

2/10/1999

1MS-94B-405-7

Pratt 1100 and 1200 Nuclear Class Valves Installation and

Maintenance Manual

24803

NUPIC Audit/Survey for Flexitallic US, LLC

2/17/2020

220

NUPIC Audit/Survey for Fairbanks Morse Defense by

Pacific Gas and Electric Company (PGE)

11/01/2022

280

NUPIC Audit/Survey for Flexitallic US, LLC

10/11/2022

Miscellaneous

4430

Inspection Plan for Spiral Wound w/o Compress

Inspection

Procedure

Type

Designation

Description or Title

Revision or

Date

4500803470-

00001-

000000325063

Purchase Order from Southern Lubricants

1/31/2023

4500825120-

00009-

000000328449

Purchase Order from Curtiss Wright Corp

3/14/2023

4515

Inspection Plan for SRI-2 Grease

CGIBE01

EPRI CGI Joint Utility Task Group Commercial Grade Item

Evaluation for Bearings - Rolling

CGICA01

EPRI CGI Join Utility Task Group Commercial Grade Item

Evaluation For Fixed Capacitors

CGIDB01

EPRI CGI Joint Utility Task Group Commercial Grade Item

Evaluation for Drive Belts

CGIFU05

EPRI CGI Joint Utility Task Group Commercial Grade Item

Evaluation for UL 1986 Listed Fuses

CGIGA01

EPRI CGI Joint Utility Task Group Commercial Grade Item

Evaluation for Gaskets, Non-Metallic (and Spiral Wound)

CGILU01

EPRI CGI Joint Utility Task Group Commercial Grade Item

Evaluation for Greases

CGIOR01

EPRI CGI Joint Utility Task Group Commercial Grade Item

Evaluation for Circular Cross Section O-Rings

Manufactured by Parker Seal Group, O-Ring Division

EQF-M-PS2-C17-

Interim Change to EOF-M-PS2-C17-1

M32938

Receiving Inspection Report for AP Services, LLC

2/9/2021

NU-02SR734120

Purchase Order: Seat, Valve, Ring, for 16"-150# Butterfly

9/23/2008

NU-02SR766303

Purchase Order: Seat, Valve, Ring, for 16"-150# Butterfly

4/18/2017

NU-02SR766505

Purchase Order for Bearing 309KDD

4/272017

NU-02SR776477

Purchase Order from Southern Lubricants

2/28/2020

PO 4500802821-

00001-323310

EH, VCS, Supplemental Fuses

01/12/2023

PO NU-

2NN777149

Capacitor, 5400MFD, -10+50%VDC, 200VDC, 250 Surge

4/27/20

PO-4500677045

Purchase Order: Bearing Distributors Inc., V-Belt, 62.2,

4/7/2021

Inspection

Procedure

Type

Designation

Description or Title

Revision or

Date

Browning Manufacturing, Part# A60,2/SET

PO-4500680130

Purchase Order from Infinity Seal: Seal, Poppet, Viton

5/13/2021

PO-4500685995

Breaker Circuit, 8A, 2P, Alltech, P/N 2G8UM

PO-4500733580

Purchase Order: Bearing Distributors Inc., V-Belt, 62.2,

Browning Manufacturing, Part# A60,2/SET

2/2/2021

PO-4500745704

Purchase Order from Infinity Seal: Seal, Poppet, Viton

1/26/2023

PO-4500823412

Purchase Order Paragon Energy Solutions LLC.

1/21/2023

PO-NU-

2SR766830

Purchase Order: Applied Industrial Technologies, V-Belt,

71, Browning Manufacturing, Part# B68,2/SET

5/17/2017

PO-NU-

2SR771187

Purchase Order: Motion Industries, V-Belt, 67.0, Browning

Manufacturing, Part# B64

9/13/2018

PO-NU-

2SR775919

Purchase Order: Bearing Distributors Inc., V-Belt, 63.0,

Browning Manufacturing, Part# B60,2/SET

1/13/2020

PR 729833

On Site Certification To Upgrade SKU#26-1126-0102-00

TO SR SKU#26-1126-0102-12.

4/27/2020

PTE

10000065699

Procurement Technical Evaluation: VCS Spriral Wound

Gaskets w/o Compress.

PTE

10000070970

Procurement Technical Evaluation: VCS-Chevron SRI-2

Grease

PTR MU-4

SCE&G Procurement Technical Requirements:

Specifications/Inspections/Testing of Elastomeric Items

10/19/1992

PTR-ET5

Capacitors

QR-351026581-1

Qualification Report for Chiller Upgrade Project Phase C

VCSNS - DBD

Diesel

Generators (DG)

Design Basis Document, Diesel Generator Engine Support

and Control Systems (DG)

VTM-1MS-94B-

643

Maintenance Instruction Manual Feedwater Isolation Valve

5/26/1992

CP-400

Administrative Guidelines for Lubricating Oils, Hydraulic

Fluids and Greases

EMP-115.028

Cyberex Inverter Maintenance

ES-0321

Procurement Of Material and Services

ES-0361

Receiving Inspection

Procedures

ES-0368

Request for Disposition

Inspection

Procedure

Type

Designation

Description or Title

Revision or

Date

ES-324

Establishment of Shelf Life Criteria

ES-325

Procurement Technical Requirements Development,

Review and Processing

ES-326

Procurement, Management and Use Of ASME Code

Material, Parts And Components

ES-342

PQ Processing of Procurement Documents

ICP-235.042

Feedwater Isolation Valves XVG01611A, B & C Rebuild

Procedure

ICP-290.026

Main Steam Isolation Valve Actuator Verification

MA-AA-100

Conduct of Maintenance

MA-AA-114

Satellite Storage Area Control

MMP-300.001

Bolted Connection Removal and Installation

MMP-300.023

Main Steam Isolation Valve Air Actuator,

XVM02801A/B/C-O-MS Maintenance

MMP-460.022

Inspection, Cleaning and Lubrication of Fan Coil Units

MS-AA-MNI-401

Material Request and Material Requirements Planning

(MRP)

MS-AA-MVL-101

Quality Receipt Inspection

MS-AA-PRO-401

Procurement Control

MS-AA-PRO-402

Purchase Orders

MS-AA-PTE-401

Procurement Technical Evaluation Determination

MS-AA-PTE-401-

1001

Issuance and Control of Procurement TQAR Notes

MS-AA-PTE-401-

1002

Sampling Methodology for Material Acceptance

MS-AA-PTE-401-

1004

Commercial Grade Dedication

MS-AA-PTE-401-

1005

Processing Procurement Technical Evaluations (PTEs) in

SAP

MS-AA-SLD-701

Shelf-Life Evaluation and Control

MS-AA-TRN-202

Procurement Engineering Services Qualification and

Certification Program

MS-AA-WHR-401

Receiving

Inspection

Procedure

Type

Designation

Description or Title

Revision or

Date

MS-AA-WHS-131

Storage and Handling

PR-01

Development Of Shelf Life Criteria

PR-02

Identification of Critical Characteristics

PR-03

CGI Acceptance Methodology

SAP-0643

SAME Code,Section XI Repair/Replacement Program

Work Orders

1909664,

2005720,

2009798,

2015584,

2115908,

1603403,

1712739,

1712739,

1716968,

1817531,

1819279,

1902137,

2005845,

2005720,

2009798,

2015584,

2106253,

2115908,

1603403,

1712739,

1716968,

1817531,

1819279,

1902137,

1909795,

2005845,

1918663,

1705031,

1708489,

Inspection

Procedure

Type

Designation

Description or Title

Revision or

Date

1708987,

1809231,

1811949,

1915572,

2007755,

2105914,

2108120,

2114383,

1916930,

88101040701