Text
George A. Lippard General Manager,Nuclear Plant Operations 803.345.4810 April 11,2011 A SCANA COMPANY Document Control Desk U. S. Nuclear Regulatory Commission Washington, DC 20555
Dear Sir/Madam:
Subject:
VIRGIL C. SUMMER NUCLEAR STATION UNIT 1 DOCKET NO. 50-395 OPERATING LICENSE NO. NPF-12 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT Enclosed is the South Carolina Electric & Gas Company (SCE&G) Annual Radioactive Effluent Release Report as required by 10CFR50.36a, Section 6.9.1.8 of the Virgil C.
Summer Nuclear Station Technical Specifications and Section 1.6.2 of the Offsite Dose Calculation Manual (ODCM). This submittal covers the period of January 1 through December 31, 2010.
Should there be any questions, please contact Ms. Susan B. Reese at (803) 345-4591.
Very truly yours, SBR/GAL/gr Enclosures c: w/o enclosure unless noted K. B. Marsh NRC Resident Inspector S. A. Byrne M. Coleman J. B. Archie M. B. Roberts N. S. Cams NSRC J. H. Hamilton T. P. O'Kelley, (SCDHEC), (w/enclosure)
R. J. White Susan Jenkins (SCDHEC)
K. J. Browne E. Everett, (ANI), (w/enclosure)
V. M. McCree RTS (LTD 313)
R. E. Martin File (818.02-1, RR 8350)
K. M. Sutton PRSF (RC-1 1-0057), (w/enclosure)
Virgil C.Summer Station.- Post Office Box 88.- Jenkinsville, SC -29065 - T(803) 345-5209 ýJ(ý
VIRGIL C. SUMMER JENKINSVILLE, SOUTH CAROLINA ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT VIRGIL C. SUMMER NUCLEAR STATION FOR THE OPERATING PERIOD JANUARY 1, 2010 - DECEMBER 31,2010 APRIL 2011 SCE&Gsm A SCANA COMPANY Prepared by:
Michelle West bury, Specialis Health Physics Reviewed by: Approved by:
Michael Roberts, Supervisor Moses Coleman, Manager Health Physics Health Physics and Safety Services
ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT JANUARY- DECEMBER, 2010 VIRGIL C. SUMMER NUCLEAR STATION SOUTH CAROLINA ELECTRIC & GAS This report is being submitted as a summary of quantities of radioactive liquid and gaseous effluents and solid waste released from the Virgil C. Summer Nuclear Station. This report satisfies the requirements in Technical Specifications Section 6.9.1.8, Offsite Dose Calculation Manual (ODCM) Sectionl.6.2 and 10CFR50.36(a). Also included is an assessment of radiation doses from plant releases.
A brief discussion of the Supplemental Information and Tables 1 through 5 is presented in Sections A through D. An evaluation of the radiological impact on man due to operation of the Virgil C. Summer Nuclear Station is presented in Section E and Table 6. There were no abnormal releases for this period. A summary of the meteorological data for 2010 is presented in Section G. There were no changes made to the Offsite Dose Calculation Manual (ODCM) during the 12-month period.Section I gives a summary of oil incineration during the year.
There were no ODCM Reportable Incidences. Section K identifies two major changes to the radwaste treatment systems approved by the Plant Safety Review Committee (PSRC) in 2010. Section L summarizes Carbon-14 gaseous effluents from the station.
A. Supplemental Information Regulatory limits for doses, dose rate and effluent concentration limits presented in Supplemental Information are from the Virgil C. Summer Nuclear Station ODCM and 40 CFR 190. Average energy (Ebar) is not applicable to the method for determining release rate limits for fission and activation gaseous effluents; therefore, it has been omitted.
B. Gaseous Effluents Gaseous effluents released from ground level are summarized in Tables 1 and 2. An elevated release pathway does not exist at Virgil C. Summer Nuclear Station. Cumulative doses are discussed in Section E.
The errors for gaseous effluent totals are given as the square root of the sum of squares of counting errors and flow or volume measurement errors. A systematic error of 15% has been added to estimate total error.
PAGE 1
ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT JANUARY- DECEMBER, 2010 VIRGIL C. SUMMER NUCLEAR STATION SOUTH CAROLINA ELECTRIC & GAS C. Liquid Effluents Liquid effluents are summarized in Tables 3 and 4. Estimated total errors are expressed as in Section B above.
D. Solid Waste Shipments Solid waste shipments are summarized in Table 5. Curie content of radioactive waste packages is determined by dose rates and/or gamma spectroscopy analysis of samples. The total error for each type of Curie content determination is conservatively estimated to be the sum of a 15% systematic error and a 20% photon response error for the detector used.
E. Radiological Impact on Man Potential doses to the maximum exposed individual in the unrestricted area were calculated using measured plant gaseous effluents and meteorological data in accordance with the Offsite Dose Calculation Manual. The source term involved no Waste Gas Decay Tank (WGDT) releases, 0.1 days of 6-inch Reactor Building purge releases, no 36-inch Reactor Building purge releases and a continuous 12-month Main Plant vent release. Oil incineration occurred for 236.7 hours8.101852e-5 days <br />0.00194 hours <br />1.157407e-5 weeks <br />2.6635e-6 months <br /> in 2010. Doses are summarized in Table 6. The total activities released are presented in Tables 1 and 2. The highest quarterly air doses to the maximum exposed individual due to noble gases were 1.57E-06 mrad for gamma during the first quarter and 5.54E-07 mrad for beta during the first quarter. The maximum quarterly organ dose attributed to the releases was 2.00E-01 mrem. Cumulative annual dose was 2.66E-06 mrad, 9.38E-07 mrad and 8.00E-01 mrem for gamma, beta, and organ dose, respectively.
Measured plant liquid effluent data was used to calculate estimates of doses to individuals in accordance with the Offsite Dose Calculation Manual. The source term consisted of the isotopic contents of 146 Waste Monitor Tank batch releases, 5 Condensate Backwash Receiver Tank batch releases, 3 NaOH batch releases, 5.2 days of Steam Generator Blowdown release and a continuous Turbine Building Sump release.
PAGE 2
ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT JANUARY - DECEMBER, 2010 VIRGIL C. SUMMER NUCLEAR STATION SOUTH CAROLINA ELECTRIC & GAS Doses are summarized in Table 6 and total radioactivity released is described in Tables 1 and 3. The highest quarterly total body dose to the maximum exposed individual due to the release of radioactive liquid was 1.26E-03 mrem during the fourth quarter. The highest organ dose was 1.30E-03 mrem to the LIVER for the fourth quarter.
Cumulative annual doses for the hypothetical maximum exposed individual were 3.40E-03 mrem for the total body and 4.21 E-3 mrem for the GI-LLI, the maximum annual organ. The GI-LLI was the maximum exposed organ for the first and second quarters, both GI-LLI and LIVER were the maximum exposed organs for the third quarter and the LIVER was the maximum exposed organ for the fourth quarter.
Dose rates and concentrations were below the limits specified in Supplemental Information, Section 2a, b, and c during all the effluent releases.
Radiation doses from radioactive effluents to members of the public due to their activities inside the site boundary were assessed using liquid and gaseous effluents along with meteorological data.
Quarterly thermoluminescent dosimetry data from four (4) monitoring locations within the site boundary and eight (8) locations around the site boundary perimeter were analyzed and compared with respective pre-operational background and previous year history. Results showed that the 2010 quarterly dose rates did not differ significantly from the pre-operational or 2009 dose rates. It was concluded that doses to members of the public inside the site boundary were indistinguishable from normal background dose.
Radiation doses from radioactive effluents to workers at the Fairfield Hydro Station for the 12-month period were calculated to be 1.25E-07 and 4.41 E-08 mrad for gamma and beta, respectively.
Radiation doses from radioactive effluents to workers at the New Nuclear Site for the 12-month period were calculated to be 7.82E-07 and 2.76E-07 mrad for gamma and beta, respectively.
PAGE 3
ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT JANUARY- DECEMBER, 2010 VIRGIL C. SUMMER NUCLEAR STATION SOUTH CAROLINA ELECTRIC & GAS Radiation doses from nearby uranium fuel cycle sources were not assessed. The ODCM, Sections 1.3.1 and B/1.3 establish a five (5) mile limit beyond which doses from nearby plants are insignificant. There are no uranium fuel cycle plants within a five (5) mile radius of Virgil C. Summer Nuclear Station.
F. Abnormal Releases During 2010, the plant had no abnormal releases.
G. Meteorology The meteorological data for 2010 was collected and evaluated.
An annual meteorological summary report providing joint frequency distributions of wind direction and speed by atmospheric stability class is maintained in plant records.
The wind direction and wind speed data used were acquired from the 10-meter level of the primary monitoring tower.
Stability was determined by the primary differential temperature (61 to 10 meter).
The combined annual data recovery for wind direction, wind speed and stability was 100%. Primary variable recovery rates were as follows: wind direction (10 m) - 100%, wind speed (10 m) - 100%,
and differential temperature (61 - 10 m) - 100%.
H. Offsite Dose Calculation Manual The Virgil C. Summer Nuclear Station ODCM was not revised in 2010.
PAGE 4
ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT JANUARY- DECEMBER, 2010 VIRGIL C. SUMMER NUCLEAR STATION SOUTH CAROLINA ELECTRIC & GAS Oil Incineration The incinerator operated for a period of 236.7 hours8.101852e-5 days <br />0.00194 hours <br />1.157407e-5 weeks <br />2.6635e-6 months <br />, burning 1122 gallons of oil at the average rate of 4.74 gal/hr. The incinerated oil contained concentrations of 1.44E-05 uCi/mI for H3, 7.70E-09 uCi/mI for Mn-54, 5.61 E-08 uCi/mI for Co-60, 2.64E-08 uCi/mI for Sb-125, 1.85E-08 uCi/ml for Cs-1 34 and 1.57E-07 uCi/mI for Cs-1 37. The dose to the maximum exposed individual from the incinerated oil was 1.21 E-05 mrem.
J. Offsite Dose Calculation Manual Reportable Incidences There were no ODCM Reportable Incidences in 2010.
K. Major Changes to Radioactive Waste Treatment Systems Two Engineering Change Requests (ECR) were approved by the PSRC in 2010.
ECR 50380 eliminated the use of the Recycle and Waste Evaporators replacing them with a temporary DURATEK demineralizer system.
ECR 50493 relocated the temporary DURATEK demineralizer system and installs the necessary equipment to establish a permanent liquid processing system. Additionally the Recycle and Waste Evaporators were abandoned in place by this ECR.
The descriptions of these changes are included in Final Safety Analysis Report Revision Notices03-038, 07-037,08-003 and 10-005.
PAGE 5
ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT JANUARY - DECEMBER, 2010 VIRGIL C. SUMMER NUCLEAR STATION SOUTH CAROLINA ELECTRIC & GAS The following design calculations were performed to verify compliance with 10 CFR 20 and 10 CFR 50 Appendix I.
- DC00030-024
- DC00030-051
- DC00030-053
- DC00030-056 The ECR packages and design calculations are maintained in plant records and are available for review.
L. Carbon-14 Gaseous Effluents Carbon-14 production and release estimates were calculated using EPRI Report 1021106, "Estimation of Carbon-14 in Nuclear Plant Gaseous Effluents". This calculation uses active core coolant mass, average neutron flux by energy and reactor coolant nitrogen concentrations to determine carbon-14 generation based upon an effective full power year. The estimated generation for VC Summer Nuclear station for 2010 was 10.05 curies.
Public dose estimates were performed using NUREG-0133 and Regulatory Guide 1.109 methodology. Carbon dioxide is assumed to make up 20% of the Carbon-14 gaseous emissions from the station based upon available references and initial on-site testing conducted in 2010.
PAGE 6
ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT JANUARY - DECEMBER, 2010 VIRGIL C. SUMMER NUCLEAR STATION SOUTH CAROLINA ELECTRIC & GAS SUPPLEMENTAL INFORMATION Regulatory Limits:
- a. Fission and Activation Gases:
The air dose to an individual due to noble gases released in gaseous effluents shall be limited to less than or equal to 5 mrad for gamma radiation and 10 mrad for beta radiation during any calendar quarter and 10 mrad for gamma radiation and 20 mrad for beta radiation during any calendar year (ODCM, Section 1.2.3.1).
- b. lodines, Particulates (half-lives > 8 days) and Tritium:
The dose to an individual from radioidines, tritium and radioactive materials in particulate form with half-lives greater than 8 days in gaseous effluents shall be limited to less than or equal to 7.5 mrem to any organ during any calendar quarter and 15 mrem to any organ during any calendar year (ODCM, Section 1.2.4.1).
- c. Liquid Effluents:
The dose or dose commitment to an individual from radioactive materials in liquid effluents released shall be limited to less than or equal to 1.5 mrem to the total body and 5 mrem to any organ during any calendar quarter and 3 mrem to the total body and 10 mrem to any organ during any calendar year (ODCM, Section 1.1.3.1).
- d. All Sources:
The annual dose equivalent shall not exceed 25 mrem to the whole body, 75 mrem to the thyroid and 25 mrem to any other organ (40 CFR 190).
- 2. Dose Rate and Effluent Concentration Limits:
- a. Fission and Activation Gases The dose rate in unrestricted areas due to radioactive materials released in gaseous effluents shall be limited to less than or equal to 500 mrem/year to the total body and less than or equal to 3000 mrem/year to the skin (ODCM, Section 1.2.2.1).
PAGE 7
ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT JANUARY- DECEMBER, 2010 VIRGIL C. SUMMER NUCLEAR STATION SOUTH CAROLINA ELECTRIC & GAS
- b. lodines, Particulates (half-lives > 8 days) and Tritium:
The dose rate in unrestricted areas due to radioactive materials in effluents shall be limited to less than or equal to 1500 mrem/year to any organ (ODCM, Section 1.2.2.1).
- c. Liquid Effluents:
The concentration of radioactive materials released from the site shall be limited to the concentrations specified in 10 CFR 20, Appendix B, Table 2, Column 2 for radionuclides other than dissolved or entrained noble gases. For dissolved or entrained noble gases, the concentration shall be limited to 2E-04 pCi/mI total activity (ODCM, Section 1.1.2.1).
- 3. Average Energy:
Not Applicable
- 4. Measurements and Approximations of Total Radioactivity:
- a. Fission and activation gases: Gamma spectrometry (HPGe)
- b. lodines: Gamma spectrometry (HPGe)
- c. Particulates: Gamma spectrometry (HPGe), beta proportional counting, alpha proportional counting
- d. Tritium: Liquid scintillation
- e. Liquid effluents: Gamma spectrometry (HPGe), liquid scintillation (H-3), beta proportional counting, alpha proportional counting.
PAGE 8
ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT JANUARY - DECEMBER, 2010 VIRGIL C. SUMMER NUCLEAR STATION SOUTH CAROLINA ELECTRIC & GAS
- 5. Batch Releases:
- a. Gaseous:
- 1. Number of batch releases: 0
- 2. Total time period for batch releases: 0 min
- 3. Maximum time period for a batch release: 0 min
- 4. Average time period for a batch release: 0 min
- 5. Minimum time period for a batch release: 0 min
- b. Liquid:
- 1. Number of batch releases:
45 For first quarter, 2010 42 For second quarter, 2010 32 For third quarter, 2010 35 For fourth quarter, 2010
- 2. Total time period for batch releases:
3.38E+03 min. for first quarter, 2010 3.13E+03 min. for second quarter, 2010 2.49E+03 min. for third quarter, 2010 2.49E+03 min. forfourth quarter 2010
- 3. Maximum time period for a batch release:
9.30E+01 min. for first quarter, 2010 9.OOE+01 min. for second quarter, 2010 8.30E+01 min. for third quarter, 2010 8.30E+01 min. for fourth quarter, 2010 PAGE 9
ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT JANUARY - DECEMBER, 2010 VIRGIL C. SUMMER NUCLEAR STATION SOUTH CAROLINA ELECTRIC & GAS
- 4. Average time period for batch releases:
7.51 E+01 min. for first quarter, 2010 7.45E+01 min. for second quarter, 2010 7.77E+01 min. for third quarter, 2010 7.12E+01 min. for fourth quarter, 2010
- 5. Minimum time period for a batch release:
6.80E+01 min. for first quarter, 2010 5.OOE+00 min. for second quarter, 2010*
6.10E+01 min. for third quarter, 2010 5.OOE+00 min. for fourth quarter, 2010*
- NaOH sump release
- 6. Average stream flow during periods of release of effluent into a flowing stream:
5.48E+06 gpm for first quarter, 2010 8.05E+06 gpm for second quarter, 2010 1.02E+07 gpm for third quarter, 2010 4.88E+06 gpm for fourth quarter, 2010
- 6. Abnormal Releases:
- a. Gaseous:
- 1. Number of releases: 0
- 2. Total activity released: 0
- b. Liquid:
- 1. Number of releases: 0
- 2. Total activity released: 0 PAGE 10
ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT January - December 2010 Virgil C. Summer Nuclear Station South CarolinaElectric & Gas Table I Gaseous Effluents Summation of All Releases m m* Im*A *m*A* A*AALm* AA4A PA*
UNI 11 FIKRS SOUUNU THIRD FOURTH 201u r-b I.
QUARTER QUARTER QUARTER QUARTER TOTAL ERROR %
i~a I I I S. I A. Fission & Activation Gases
- 1. Total release Ci 8.46E-04 5.87E-04 0.00E+00 0.OOE+00 1.43E-03 31.99
- 2. Average release rate uCi Isec 1.09E-04 7.47E-05 0.OOE+00 0.00E+00 4.54E-05
- 3. Percent ODCM Qtr. gamma air dose limit 3.14E-05 2.18E-05 0.00E+00 0.00E+00 N/A
- 4. Percent ODCM annual gamma air dose limit 1.57E-05 2.66E-05
- 2.66E-05
- 2.66E-05
- 2.66E-05
- 5. Percent ODCM Qtr. beta air dose limit 5.54E-06 3.84E-06 0.00E+00 0.OOE+00 N/A
- 6. Percent ODCM annual beta air dose limit 2.77E-06 4.69E-06
- 4.69E-06
- 4.69E-06
- 4.69E-06 B. lodines 1.Total iodine - 131 Ci 0.00E+00 0.00E+00 0.OOE+00 0.00E+00 0.OOE+00 N/A
- 2. Average release rate uCi/sec 0.00E+00 0.00E+00 0.OOE+00 0.00E+00 0.OOE+00 C. Particulates
- 1. Particulates with half - lifes > 8 days Ci 0.00E+00 1.81 E-05 3.81 E-06 5.80E-06 2.77E-05 81.11
- 2. Average release rate uCi /sec 0.00E+00 2.30E-06 4.79E-07 7.29E-07 8.78E-07
- 3. Gross alpha radioactivity Ci 0.00E+00 0.00E+00 0.OOE+00 0.OOE+00 0.OOE+00 D. Tritium
- 1. Total release Ci 1.72E-04 4.60E-04 0.OOE+00 0.00E+00 6.31 E-04 44.47
- 2. Average release rate uCi / sec 2.21 E-05 5.85E-05 0.00E+00 0.00E+00 2.OOE-05 E. Carbon 14
- 1. Total release Ci 2.51E+00 2.51 E+00 2.51 E+00 2.51 E+00 1.01 E+01 N/A
- 2. Average release rate uCi/sec 3.23E-01 3.19E-01 3.16E-01 3.16E-01 3.18E-01 F. Organ Dose (from B,C,and D)
- 1. Percent ODCM Qtr. organ dose limit 1.21 E-06 3.23E-06 0.00E+00 0.OOE+00 N/A
- 2. Percent 00CM annual orqan dose limit 6.03E-07 2.22E-06
- 2.22E-06
- 2.22E-06
- 2.22E-06
- Cumulative
ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT JANUARY - DECEMBER, 2010 TABLE 2 GASEOUS EFFLUENTS -- GROUND-LEVEL RELEASES Continuous Mode Batch Mode I Nuclides Released Units I First Quarter Second Quarter Third Quarter Fourth Quarter Annual Total First Quarter Second Quarter Third Quarter Fourth Quarter Annual Total 1 Fission gases Krypton-85 Ci 0 0 0 0 0 0 0 0 0 0 Krypton-85m Ci 0 0 0 0 0 0 0 0 0 0 Krypton-87 Ci 0 0 0 0 0 0 0 0 0 0 Krypton-88 Ci 0 0 0 0 0 0 0 0 0 0 Xenon-131m Ci 0 0 0 0 0 0 0 0 0 0 Xenon-133 Ci 0 0 0 0 0 0 0 0 0 0 Xenon-133m Ci 0 0 0 0 0 0 0 0 0 0 Xenon-135 Ci 0 0 0 0 0 0 0 0 0 0 Xenon-135m Ci 0 0 0 0 0 0 0 0 0 0 Xenon-138 Ci 0 0 0 0 0 0 0 0 0 0 Other: Ar-41 Ci 8.46E-04 5.87E-04 0 0 1.43E-03 0 0 0 0 0 Unidentified: None Ci 0 0 0 0 0 0 0 0 0 0 Total for Period Ci 8.46E-04 5.87E-04 0 0 1.43E-03 0 0 0 0 0 2 lodines and other halogens Iodine-131 Ci 0 0 0 0 0 0 0 0 0 0 Iodine-132 Ci 0 0 0 0 0 0 0 0 0 0 Iodine-133 Ci 0 0 0 0 0 0 0 0 0 0 Br-82 Ci 0 0 0 0 0 0 0 0 0 0 Unidentified: None Ci 0 0 0 0 0 0 0 0 0 0 Total for Period Ci 0 0 0 0 0 0 0 0 0 0 3 Particulates Cromium-51 Ci 0 0 0 0 0 0 0 0 0 0 Manganese-54 Ci 0 0 0 0 0 0 0 0 0 0 Cobalt-58 Ci 0 0 0 0 0 0 0 0 0 0 Cobalt-60 Ci 0 0 0 0 0 0 0 0 0 0 Stronium-89 Ci 0 0 0 0 0 0 0 0 0 0 Stronium-90 Ci 0 0 0 0 0 0 0 0 0 0 Niobium-95 Ci 0 0 0 0 0 0 0 0 0 0 Cesium-134 Ci 0 0 0 0 0 0 0 0 0 0 Cesium-137 Ci 0 0 0 0 0 0 0 0 0 0 Other: Be-7 Ci 0 1.81E-05 3.81E-06 5.80E-06 2.77E-05 0 0 0 0 0 Unidentified: None Ci 0 0 0 0 0 0 0 0 0 0 Total for Period Ci 0 1.81E-05 3.81E-06 5.80E-06 2.77E-05 0 0 0 0 0
- Tritium and Carbon-14 not included. See Table 1.
ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT JANUARY-DECEMBER, 2010 Virgil C. Summer Nuclear Station South CarolinaElectric & Gas TABLE 3 Liquid Effluents Summation of All Releases FIR5T SECOND THIRU FOURTH 2010 EST.
UNITS QUARTER QUARTER QUARTER QUARTER TOTAL ERROR %
A. Fission & Activation Products
- 1. Total release Ci 5.09E-03 3.01E-03 3.26E-03 2.88E-03 1.42E-02 19.65
- 2. Average diluted concentration uCi/ml 1.54E-11 8.42E-12 9.17E-12 1.11E-11 1.09E-11 B. Tritium
- 1. Total release Ci 2.12E+01 1.02E+02 2.05E+02 1.09E+02 4.36E+02 18.05
- 2. Average diluted concentration uCi/ml 6.41 E-08 2.85E-07 5.76E-07 4.19E-07 3.35E-07 C. Dissolved and entrained gases
- 1. Total release Ci 9.87E-06 3.75E-05 7.55E-04 6.21E-04 1.42E-03 19.77
- 2. Average diluted concentration uCilml 2.98E-14 1.05E-13 2.12E-12 2.39E-12 1.09E-12 3.Percent ODCM limit ( 2.OE-4 uCilmi) % 1.49E-08 5.24E-08 1.06E-06 1.20E-06 5.46E-07 D. Gross alpha radioactivity
- 1. Total release Ci 0 0 0 0 0 N/A E. Volume of waste released (undiluted) liters 1.71 E+07 1.63E+07 1.28E+07 1.57E+07 6.19E+07 3.0 F. Volume of dilution water liters 3.31E+11 3.57E+11 3.55E+11 2.60E+11 1.30E+12 4.3 G. ODCM limits (from A and B)
- 1. Percent of ODCM Qtr total body limit % 1.77E-02 5.53E-02 6.96E-02 8.41E-02 N/A
- 2. Percent of ODCM annual total body limit % 8.83E-03 3.65E-02
- 7.13E-02
- 1.13E-01
- 1.13E-01 *
- 3. Percent of ODCM Qtr max. organ limit** % 2.06E-02 1.84E-02 2.12E-02 2.59E-02 N/A
- 4. Percent of ODCM annual max. organ limit** % 1.03E-02 1.95E-02
- 3.01 E-02
- 3.47E-02
- 4.21 E-02 *
- Cumulative
- See page 3 for max. organ for each quarter and cumulative.
ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT JANUARY - DECEMBER, 2010 Virgil C. Summer Nuclear Station, South CarolinaElectric & Gas TABLE 4 LIQUID EFFLUENTS Continuous Mode Batch Mode INucides Released*I Units First Second Third Fourth Annual First Second Third Fourth Annual I I_ IQuarter Quarter Quarter Quarter Total Quarter Quarter Quarter Quarter Total Strontium-89 Ci 0 0 0 0 0 0 0 0 0 0 Strontium-90 Ci 0 0 0 0 0 0 0 0 1.45E-05 1.45E-05 Cesium-134 Ci 0 0 0 0 0 1.07E-05 1.65E-05 2.29E-05 3.30E-05 8.31E-05 Cesium-137 Ci 0 0 0 0 0 6.05E-05 7.34E-05 1.13E-04 1.29E-04 3.76E-04 Iodine-131 Ci 0 0 0 0 0 0 0 0 0 0 Cobalt-57 Ci 0 0 0 0 0 1.48E-06 0 0 0 1.48E-06 Cobalt-58 Ci 0 0 0 0 0 1.27E-03 2.66E-04 1,14E-04 3.86E-05 1.69E-03 Cobalt-60 Ci 0 0 0 0 0 1.10E-03 7.67E-04 1.04E-03 9.34E-04 3.84E-03 Iron-59 Ci 0 0 0 0 0 1.69E-05 5.21E-06 6.75E-06 0 2.89E-05 Zinc-65 Ci 0 0 0 0 0 1.OOE-05 9.27E-06 3.80E-06 0 2.31E-05 Manganese-54 Ci 0 0 0 0 0 2.05E-04 1.10E-04 1.30E-04 8.05E-05 5.26E-04 Chromium-51 Ci 0 0 0 0 0 4.37E-04 0 0 0 4.37E-04 Zirconium-Niobium-95 Ci 0 0 0 0 0 6.38E-04 1.28E-04 8.55E-05 8.76E-06 8.60E-04 Molybdenum-99 Ci 0 0 0 0 0 0 0 0 0 0 Technetiumn-99m Ci 0 0 0 0 0 0 0 0 0 0 Cerium-144 Ci 0 0 0 0 0 0 0 0 0 0 Other: Be-7 Ci 0 0 0 0 0 0 0 4.27E-05 9.OOE-06 5.17E-05 Na-24 Ci 0 0 0 0 0 0 0 0 0 0 Fe-55 Ci 0 0 0 0 0 0 1.21E-03 1.56E-03 1.52E-03 4.29E-03 Nb-95m Ci 0 0 0 0 0 0 1.10E-06 0 0 1.10E-06 Ag-ll0m Ci 0 0 0 0 0 0 0 0 0 0 Sn-l13 Ci 0 0 0 0 0 1.19E-06 0 0 5.52E-07 1.74E-06 Sb-122 Ci 0 0 0 0 0 0 0 1.01E-06 0 1.01E-06 Sb-124 Ci 0 0 0 0 0 8.03E-06 1.09E-05 0 0 1.89E-05 Sb-125 Ci 0 0 0 0 0 2.43E-04 4.09E-04 1.46E-04 1.09E-04 9.07E-04 Te-123m Ci 0 0 0 0 0 1.86E-06 0 6.49E-07 0 2.51E-06 Te-125m Ci 0 0 0 0 0 1.08E-03 0 0 0 1.08E-03 Te-129m Ci 0 0 0 0 0 0 0 0 0 0 1-135 Ci 0 0 0 0 0 0 0 0 0 0 Total for Period (above) Ci 0 0 0 0 0 5.08E-03 0 3.27E-03 0 1.42E-02 Ar-41 Ci 0 0 0 0 0 0 0 0 0 0 Kr-85m Ci 0 0 0 0 0 0 0 0 0 0 Kr-88 Ci 0 0 0 0 0 0 0 0 0 0 Xenon-133 Ci 0 0 0 0 0 8.86E-06 3.75E-05 7.01E-04 6.17E-04 1.36E-03 Xenon-133m Ci 0 0 0 0 0 0 0 1.74E-05 4.43E-06 2.18E-05 Xenon-135 Ci 0 0 0 0 0 1.01E-06 0 3.65E-05 0 3.75E-05 Total Entrained Gases Ci 0 0 0 0 0 9.87E-06 3.75E-05 7.55E-04 6.21E-04 1.42E-03
- Tritium not included. See Table 3 for tritium numbers -------
No Unidentified nuclides found
ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT January - December, 2010 Virgil C. Summer Nuclear Station South CarolinaElectric & Gas Table 5 SOLID WASTE SHIPMENTS
- 1. Solid Waste Shipped Offsite for Burial or Disposal (Not irradiated fuel).
Type of Waste Unit 2010 Est. Total Total Error, %
- a. Spent resins, filters, sludge, m* 1.27E+01 +/-25 evaporator bottoms, etc. Ci 8.80E+01
- b. Dry compressible waste m 1.21 E+02 +/-25 contaminated equip., etc. Ci 1.73E-01
- c. Irradiated components, m3 0 control rods, etc. Ci 0 N/A
- d. Other m 0 Ci 0 N/A
- 2. Estimate of major nuclide composition for the year (by type of waste) for concentrations above 1.0%. Activities for nuclides are in Curies.
Fe-55 55.9% 4.92E+01 Ni-63 27.8% 2.45E+01 Co-60 7.6% 6.69E+00 Mn-54 4.4% 3.84E+00 Sb-125 1.0% 8.51E-01 Cs-137 1.0% 7.05E-01 H-3 55.1% 9.55E-02 Co-60 9.3% 1.62E-02 Ni-95 8.6% 1.50E-02 Co-58 6.4% 1.1OE-02 Zr-95 4.8% 8.26E-03 Cr-51 4.4% 7.70E-03 Fe-55 4.0% 6.84E-03 Mn-54 1.9% 3.24E-03 Ni-63 1.7% 2.90E-03 Sb-125 1.0% 1.79E-03 None N/A N/A
- d. None N/A N/A
ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT January - December, 2010 Virgil C. Summer Nuclear Station South CarolinaElectric & Gas Table 5 SOLID WASTE SHIPMENTS
- 3. Solid Waste Disposition Numbers of Shipments Mode of Transportation Destination 3 HittmanTrucking Barnwell Disposal Facility 1 ECS/Hubbard Trucking Impact Services I Specialty Transport Inc. Impact Services I i Notes:
Twelve (12) partial shipments of DAW were made from Studsvik (Memphis, TN) to Envirocare (Clive, UT) totaling 439.7ft3 .
Four (4) shipments were sent for direct burial at Barnwell Disposal Facility (Barnwell, SC).
One (1) shipment was sent to the Barnwell Processing Facility and disposed of at the Barnwell Disposal Facility.
ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT JANUARY- DECEMBER 2010 Virgil C. Summer Nuclear Station South CarolinaElectric & Gas Table 6 GASEOUS AND LIQUID DOSES
-.- - - - - --.-----.--------------------.....- - - - - - - -. IA ... . .. .*
FIRST QUARTER SECOUND QUARTER THIRIID QUARTER FOURIH QUARTEIR TIOAL 1 Y - I ¶ F - I Y - -
ODCM Percent Percent Percent Percent ANNUAL Section GASEOUS LIMITS DOSE of Limit DOSE of Limit DOSE of Limit DOSE of Limit DOSE 1.2.3.1.a,b 5 mrad gamma / qtr. 1.57E-06 mrad 3.14E-05 1.09E-06 mrad 2.18E-05 0.00E+00 mrad 0.00E+00 0.00E+00 mrad 0.00E+00 2.66E-06 10 mrad gamma / yr. 1.57E-05 2.66E-05 2.66E-05
- 2.66E-05
- 1.2.3.1.a,b 10 mrad beta / qtr. 5.54E-07 mrad 5.54E-06 3.84E-07 mrad 3.84E-06 0.00E+00 mrad 0.00E+00 0.00E+00 mrad 0.00E+00 9.38E-07 20 mrad beta / yr. 2.77E-06 4.69E-06* 4.69E-06
- 4.69E-06
- 1.2.4.1.a,b 7.5 mrem organ/qtr 2.OOE-01 mrem** 2.67E+00 2.00E-01 mrem** 2.67E+00 2.00E-01 mrem** 2.67E+00 2.00E-01 mrem** 2.67E+00 8.OOE-01 15 mrem organ/yr. 1.33E+00 2.67E+00 4.OOE+00
- 5.34E+00
- LIQUID LIMITS 1.1.3.1a,b 1.5 mrem/ qtr. 2.65E-04 mrem 1.77E-02 8.30E-04 mrem 5.53E-02 1.04E-03 mrem 6.96E-02 1.26E-03 mrem 8.41 E-02 3.40E-03 3 mrem /yr. 8.83E-03 3.65E-02
- 7.13E-02
- 1.13E-01
- 1.1.3.1a,b 5 mrem organ/qtr*** 1.03E-03 mrem 2.06E-02 9.21 E-04 mrem 1.84E-02 1.06E-03 mrem 2.12E-02 1.30E-03 mrem 2.59E-02 4.21 E-03 10 mrem organ/yr. (GI-LLI) 1.03E-02 (GI-LLI) 1.95E-02 * (Liver)/(GI-LLI) 3.01 E-02 * (Liver) 3.47E-02 * (GI-LLI)
- Includes contribution from previous quarters
- Includes dose from all nuclides
- See page 3 for max organ for each quarter